HomeMy WebLinkAboutPermit EL11-0089 - CORELINK DATA CENTER - GENERATORCORELINK DATA CENTER 3417 S 120 PL EXPIRED 11-28-11 EL1 1 -0089 Parcel No.: Address: Tenant Name: City* Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.ci.tukwila.wa.us 1023049069 3417 S 120 PL TUKW CORELINK DATA CENTER ELECTRICAL PERMIT Permit Number: EL11 -0089 Issue Date: 02/28/2011 Permit Expires On: 08/27/2011 Owner: Name: SABEY CORPORATION Address: 12201 TUKWILA INTL BLVD 4THFL , SEATTLE WA 98168 Contact Person: Name: PAT BURKE Address: 900 N 34 ST, SUITE 108 , SEATTLE WA 98103 Contractor: Name: TITAN ELECTRIC INC Address: 900 N 34 ST, SUITE 108 , SEATTLE WA 98103 Contractor License No: TITANEI963OB Phone: 206 - 235 -2570 Phone: 206 - 633 -2811 Expiration Date: 09/02/2012 DESCRIPTION OF WORK: ELECTRICAL FOR NEW BACK UP GENERATOR. NO ADDED LOADS Value of Electrical Work: NRES: $300,000.00 RES: $0.00 Type of Fire Protection: UNKNOWN Electrical Service Provided by: SEATTLE CITY LIGHT Permit Center Authorized Signature: Fees Collected: $4,898.00 National Electrical Code Edition: 2008 Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the p ormance of work. I am authorized to sign and obtain this electrical permit and agree to the conditions on the back of this permit. Signature: Date: Print Name: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. l�gr- v doc: EL -9/09 EL11 -0089 Printed: 02 -28 -2011 • 1 PERMIT CONDITIONS Permit No. EL11 -0089 * *ELECTRICAL ** 1: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 2: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 3: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 4: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 5: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, arty violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 6: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. doc: EL-9/09 EL11 -0089 Printed: 02 -28 -2011 CITY OF TUKWIL A� Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://wwwci.tukwila.wa.us Electrical Permit No. 'PI_ 11 Wg / Project No. (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: 3z(17-- 5 ad �/ Tenant Name: CD- �� (c-Gw- Property Owners Name: .J King Co Assessor's Tax No.: l Q 2. 3o ` gob! Suite Number: Floor: Mailing Address: 3?/7 / S I Lar4 /9/4€4_ New Tenant: ❑ Yes ©..No 9Bi69 Zip raekrie City State CONTACT PERSON - Who do we contact when your permit is ready to be issued Mailing e ress: 9 A% -1110- ¢ E -Mail Address: ,�% ba bf4.4t �2�LE,1i7 0/ . Ai Name: L &.41/2 Day Telephone: 29& - 2 35 Zsi-a City State Zip Fax Number: 246— 314 Zi 2 8 ELECTRICAL CONTRACTOR INFORMATION Company Name: 1 t 1 (l e- Mailing Address: 'ay A/ Ptah Contact Person: (A0 4 E -Mail Address: Contractor Registration Number: `(? `.n 67/b3,15 City Day Telephone: Fax Number: Expiration Date: t 4 173 State Zip Zo6 - (, 13. it ti X0(4- 37-Y -zta e, 41_z,. 111— Valuation of Project (contractor's bid price): $ 0a2 Scope of Work (please provide detailed information): 'Vo adddL / d. 3eoIo00. ci_ ct l IA•N• (?71 -t. L 149 Will service be altered? ki Yes ❑ No Type of Use: Type of work: A New ❑ Addition ❑ Service Change ❑ Low Voltage ❑ Generator ❑ Fire Alarm Property Served by: ❑ Puget Sound Energy [.R Seattle City Light H \Applications \Forms - Applications On Line \4-2007 - Electrical Permit Applicat on.doc bh Adding more than 50 amps? ❑ Yes -No ❑ Remodel ❑ Tenant Improvement ❑ Telecommunication ❑ Temporary Service Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $140.00 (including an attached garage) ❑ Garages, pools, spas and outbuildings $75.00 ea ❑ Low voltage systems (alarm, furnace thermostat) $55.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $75.00 (no added /altered circuits) ❑ Service change with added /altered circuits $75.00 number of added circuits $10.00 ea ❑ Circuits added /altered without service change $50.00 (up to 5 circuits) ❑ Circuits added /altered without service change $50.00 (6 or more circuits) $7.00 ea ❑ Meter /mast repair $65.00 ❑ Low voltage systems $55.00 (alarm, furnace thermostat) MULTI - FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $58.00 ❑ Temporary service (generator) $75.00 ❑ Manufactured /mobile home service $80.00 (excluding garage or outbuilding) ❑ Carnivals $75.00 Number of concessions $10.00 ea PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNE OR ELECTRICAL CONTRACTOR: Signa . e: Print N Mailing Address: Day Telephone: Stec. City Date: 2 e4(1- 633 -M W wn State 9063 Zip Date Application Accepted: Date Application Expires: Staff Initials: Me H: \A pp can ons \Forms- Appl'cations On Line\4 -2007 - Electncal Permit Apphcation.doc bh Page 2 of 2 ill • C City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 -431 -3665 Web site: http: //www.ci.tukwila.wa.us Parcel No.: 1023049069 Address: 3417 S 120 PL TUKW Suite No: Applicant: CORELINK DATA CENTER RECEIPT Permit Number: EL11 -0089 Status: PENDING Applied Date: 02/03/2011 Issue Date: Receipt No.: R11 -00213 Payment Amount: $4,898.00 Initials: WER Payment Date: 02/03/2011 03:03 PM User ID: 1655 Balance: $0.00 Payee: TITAN ELECTRIC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 10062 4,898.00 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.00 ELECTRICAL PLAN - NONRES 000.345.832.00.00 Total: $4,898.00 3,918.40 979.60 doc: Receiot -06 Printed: 02 -03 -2011 I INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -367 Permit Inspection Request Line (206) 431 -2451 Project: (tlizav44. Type of Inspection: D Address: X3115'1204 - Date Called: Special Instructions: Date Wanted: / / c m Requester: rr Phone No: Approved per applicable codes. aCorrections required prior to approval. COMMENTS: A4.1, Saber5 ti(-46Kmmill\ Inspector: I� Date: 0610 (frr REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. • City of Tukwila • Jim Haggerton, Mayor Department of Community Development Jack Pace, Director PAT BURKE 900 N 34 ST, SUITE 108 SEATTLE WA 98103 RE: Permit No. EL11 -0089 CORELINK DATA CENTER - GENERATOR 3311 S 120 PL TUKW Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and /or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 11/28/2011. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 11/28/2011, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File: Permit File No. EL11 -0089 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 SEW CUM Y • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL11 -0089 DATE: 02 -03 -11 PROJECT NAME: CORELINK DATA CENTER SITE ADDRESS: 3417 S 120 PL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: Building Ledn • Public Works n Fire Prevention Structural Planning Division n Permit Coordinator 11 DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 02-08-11 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 03 -08 -11 Not Approved (attach comments) n DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 Contractors or Tradespeople Printer Friendly Page • Electrical Contractor A business licensed by LW to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company TITAN ELECTRIC INC 2066332811 900 N 34Th Ste 108 Seattle WA 98103 King Corporation UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 602250925 Active TITANEI9630B Electrical Contractor 9/2/2004 9/2/2012 General Unused Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status TITANE'986Q5 TITAN ELECTRIC Electrical Contractor General Unused 11/25/2002 11/25/2004 Expired Electrical Administrator INFORMATION License CROOKT'011 PB Name CROOK, TRAVIS Status Active Business Owner Information Name Role Effective Date Expiration Date FUNG, LAWRENCE H Agent 09/02/2004 8/10/2009 BURKE, PATRICK D President 09/02/2004 $1,000.00 FUNG, LAWRENCE H Secretary 09/02/2004 ELECTRICAL CITATION CROOK, TRAVIS J Vice President 09/02/2004 8/25/2008 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 COLONIAL AM CAS Et SURETY OF MD LPM4066933 08/03/2004 Until Cancelled $4,000.00 08/10/2004 Assignment of Savings Information No records found for the previous 6 year period Insurance Information No records found for the previous 6 year period Summons /Complaint Information Summons and Complaints are not filed with the department for this contractor type Warrant Information Warrants are not filed with the department for this contractor type Infractions /Citations Information Infraction / Citation Date RCW Code Type Status Violation Amount EREEB00416 8/10/2009 19.28.101 RCW ELECTRICAL CITATION Satisfied $1,000.00 EREEB00206 2/20/2009 19.28.101 RCW ELECTRICAL CITATION Satisfied $250.00 ECHAE00321 8/25/2008 19.28.101 RCW ELECTRICAL CITATION Satisfied 5250.00 EOXFJ00469 7/29/2010 19.28.101 RCW ELECTRICAL CITATION Satisfied 52,000.00 https: // fortress .wa.gov /lni/bbip /Print.aspx 02/28/2011 Feb 02, 2011, 1 :• 03pm Architectural Engineering Design Group, Inc. J:11775.01 — Corelink Seattle 11 1E /ec lE00 — ELECTR ICAL COVER SHEET. dwg WIRING DEVIGES izP $ro iet WALL MOUNTED J -BOX NON -FUSED DISCONNECT SWITCH FUSED DISCONNECT SWITCH MAGNETIC CONTROLLER (STARTER) COMBINATION STARTER/DISCONNECT SWITCH THERMAL OVERLOAD SWITCH MOTOR — NORMALLY CLOSED CONTACT —I I— NORMALLY OPEN CONTACT DISTRIBUTION AND RAGEWAY 3 n MAIN DISTRIBUTION CENTER (MDC) SURFACE MTD PANELBOARD RECESSED PANELBOARD TRANSFORMER —10314. BRANCH CIRCUIT HOMERUN CONDUIT CONGEALED IN FLOOR OR UNDERGROUND CONDUIT EXPOSED OR CONGEALED IN WALL OR CEILING o RACEWAY UP • RACEWAY DOWN ] GAPPED CONDUIT CURRENT TRANSFORMER --^-- CIRCUIT BREAKER SWITCH •—--(__'_) FUSED SWITCH I F- GROUND eir METER ABBREVIATIONS AND SYMBOLS EG ELECTRICAL CONTRACTOR GGT CIRCUIT N NEUTRAL G GROUND l6 ISOLATED GROUND 6Fl GROUND FAULT INTERRUPTOR wP WEATHER PROOF AC ABOVE COUNTER - VERIFY HEIGHT AFF ABOVE FINISH FLOOR UON UNLESS OTHERWISE NOTED EM EMERGENCY GP CHILDPROOF Ewc ELECTRICAL WATER COOLER EF EXHAUST FAN (E) EXISTING TO REMAIN (ER) EXISTING TO BE RELOCATED (W EXISTING TO BE REMOVED (RU RELOCATED LOCATION (N) NEW DEVICE Gr CURRENT TRANSFORMER MDF MAIN DISTRIBUTION FACILITY Dr INTERMEDIATE DISTRIBUTION FACILITY TTs TELEPHONE TERMINAL BOARD O POOL EQUIPMENT SCHEDULE NOTATION KITCHEN EQUIPMENT SCHEDULE NOTATION MECHANICAL EQUIPMENT SCHEDULE NOTATION DETAIL NOTE DELTA REVISION NOTE ELECTRICAL WIRE SIZE SEPARATE PERMIT REQUIRED FOR: Mechanical ❑ Electrical EePlumbing £as Piping City of Tukwila F,.. IN a DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. ELECTRICAL SPECIFICATION AND GENERAL NOTES THE CONTRACTOR SHALL PROVIDE ALL LABOR AND MATERIAL NECESSARY FOR A COMPLETE AND FUNCTIONING ELECTRICAL SYSTEM. 2. MATERIALS AND INSTALLATION SHALL COMPLY WITH CODES, LAWS AND ORDINANCES OF FEDERAL, STATE AND LOCAL GOVERNING BODIES HAVING JURISDICTION. 3. MATERIALS AND EQUIPMENT SHALL BE LISTED AND /OR LABELED BY U.L., ETL, GSA OR ANOTHER RECOGNIZED TESTING LAB. 4. THE CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS, GOVERNMENTAL FEES, TAXES AND LICENSES NECESSARY FOR THE PROPER EXECUTION AND COMPLETION OF THE ELECTRICAL WORK. THE CONTRACTOR SHALL PREPARE AND SUBMIT TO GOVERNMENTAL AGENCIES AND UTILITY COMPANIES SHOP DRAWINGS, WHICH ARE REQUIRED BY THESE AGENCIES, FOR THEIR APPROVAL. THE CONTRACTOR SHALL NOTIFY THE ENGINEER/OWNER OF ANY MATERIALS OR APPARATUS BELIEVED TO BE INADEQUATE, UNSUITABLE, IN VIOLATION OF LAWS, ORDINANCES, RULES OR REGULATIONS OF AUTHORITIES HAVING JURISDICTION. THE CONTRACTOR SHALL CAREFULLY EXAMINE THE CONTRACT DOCUMENTS, VISIT THE SITE, AND THOROUGHLY BECOME FAMILIAR WITH THE BUILDING STANDARDS AND LOCAL CONDITIONS RELATING TO THE WORK. FAILURE TO 120 50 WILL NOT RELIEVE THE CONTRACTOR OF THE OBLIGATIONS OF THE CONTRACT. ALL MATERIALS, AND EQUIPMENT SHALL BE ERECTED, INSTALLED, CONNECTED, GLEANED, ADJUSTED, TESTED, CONDITIONED, AND PLACED IN SERVICE IN ACCORDANCE WITH THE MANUFACTURER'S DIRECTIONS AND RECOMMENDATIONS. 4. ALL GUTTING, DRILLING AND PATCHING OF MASONRY, STEEL OR IRON WORK BELONGING TO THE BUILDING MUST BE DONE BY THIS CONTRACTOR IN ORDER THAT HIS WORK MAY BE PROPERLY INSTALLED, BUT UNDER NO CONDITIONS MAY STRUCTURAL WORK BE GUT, EXCEPT AT THE DIRECTION OF THE ARCHITECT- DESIGNER OR THEIR REPRESENTATIVE. 10. SHOP DRAWINGS SHALL INCLUDE MANUFACTURER'S NAMES, CATALOG NUMBERS, GUTS, DIAGRAMS AND OTHER SUCH DESCRIPTIVE DATA AS MAY BE REQUIRED TO IDENTIFY AND REVIEW THE EQUIPMENT. SUBMITTALS SHALL BE IN LOGICAL GROUPS, FOR EXAMPLE, ALL LIGHTING FIXTURES, PARTIAL SUBMITTALS WILL NOT BE REVIEWED. II. SUBMIT (3) COPIES OF THE A. PANELBOARDS B. G. D. DISCONNECTS PROVIDE "AS- BUILT" UPS E. BATTERIES FOLLOWING SHOP DRAWINGS FOR REVIEW. DRAWINGS AND SUBMIT TO OWNER/ENGINEER. 12. ALL MATERIAL, EQUIPMENT, WIRING DEVICES, ETC. 51-IALL BE NEW, UNLESS SPECIFICALLY INDICATED AS EXISTING TO BE REUSED. 13. EXCEPT AS NOTED OTHERWISE, ALL WORK REQUIRED FOR THE INSTALLATION AS SHOWN ON DRAWINGS INCLUDING LABOR, EQUIPMENT AND MATERIALS SHALL BE IN STRICT COMPLIANCE WITH THE BUILDING STANDARDS. 14. PROVIDE COMPLETE METAL RACEWAY SYSTEMS AND ENCLOSURES FOR ALL WIRING THROUGHOUT THE EXTENT OF THE REQUIRED SYSTEM. 15. ELECTRICAL METALLIC TUBING (EMT) SHALL BE USED FOR ALL WALL OUTLETS 4 TELEPHONE OUTLETS RUNNING IN PARTITIONS, BELOW RAISED FLOOR OR ABOVE CEILINGS. EMT FITTINGS SHALL BE OF THE STEEL COMPRESSION TYPE OR STEEL SET SCREW FITTINGS. 16. MINIMUM CONDUIT SIZE SHALL BE 3/4" UNLESS OTHERWISE INDICATED. 11. WIRE NO. 8 AND SMALLER FOR U5E IN INTERIOR DRY LOCATIONS SHALL BE TYPE THWN/THNN THERMOPLASTIC 600 VOLT INSULATED COPPER CONDUCTORS. FEEDERS AND POWER WIRING NO. 6 OR LARGER SHALL BE TYPE THWN 600 VOLT INULATED COPPER. WIRE WHICH 15 INSTALLED IN RACEWAYS IN MOIST OR DAMP LOCATIONS SHALL BE TYPE XHHW, 600 VOLT INSULATED COPPER CONDUCTORS. NO WIRE SMALLER THAN NO. 12 AWG SHALL BE USED FOR LIGHTING OR POWER WIRING. WIRE NO. IO AND SMALLER MAY BE SOLID OR STRANDED, WIRE NO. 8 AND LARGER SHALL BE STRANDED. I. ALL NEW CIRCUITS SHALL HAVE AGROUND WIRE INSTALLED. la. ALL WIRING NOT INSTALLED IN CONDUIT AND INSTALLED IN THE CEILING SPACE SHALL BE PLENUM RATED. 20. ALL NEW CIRCUIT BREAKERS FOR NEW OR EXISTING PANELBOARDS SHALL MATCH EXISTING BUILDING PANELBOARD MANUFACTURER AND BREAKER TYPE. THE CONTRACTOR SHALL PROVIDE NEW TYPE WRITTEN PANEL DIRECTORIES FOR ALL NEW PANELS AND EXISTING PANELS WHICH HAVE CHANGED. 21. 22. 23. 24. ELECTRICAL CONTRACTOR SHALL PROVIDE ALL SPECIAL OUTLET BOXES THAT MAY BE REQUIRED TO ENCLOSE RECEPTACLES. IN SUSPENDED CEILINGS, SUPPORT CONDUIT AND JUNCTION BOXES DIRECT FROM THE STRUCTURAL SLAB, DECK, OR FRAMING PROVIDED FOR THAT PURPOSE. SHOULD ACTUAL FIELD CONDITIONS REQUIRE INDICATED CIRCUIT DESIGNATIONS TO VARY, INDICATE THE CIRCUIT NUMBER USED ON THE "AS- BUILT" DRAWINGS. G.G. SHALL INCLUDE IN HIS COST THE REMOVAL OF ALL EXISTING ELECTRICAL DEVICES, CONDUITS, FIXTURES AND EQUIPMENT. DISCARD ALL EQUIPMENT AS REQUIRED. E.G. SHALL BE RESPONSIBLE FOR DISCONNECTING PRIMARY SERVICE AND TEMPORARY POWER. 25. ALL EXISTING ELECTRICAL SERVICES NOT SPECIFICALLY INDICATED TO BE REMOVED OR ALTERED SHALL REMAIN AS THEY PRESENTLY EXIST. 26. ALL EXTERIOR CONDUIT SHALL BE RIGID GALVANIZED STEEL (RCS). LE COPY Permit NoFI. 9 Plan review approval Is sum to eff0113 and on tone. 4 troval of construction documents does not authorize I.h violation of any added code or ordinance. Receipt of approved Field . and condltions is admowledged: By II',,�,r..a. evi Date: r.•...■■•r City o?1 lie BUDDING DIVISION Lt1 0089 REVIEWED .FGH COMPLIANCE OC N�CTH FEB 162011 City of Tukwila BUILDING DIVISION RECEIVED FEB 0 3 2011 PERMIT CENTER z w• w u Z Z - o Q � ocu Z u — w I W u O W I— z z Z a W � U a� 0 w U Z� J o W N CC V1 O� U M 0 DESCRIPTION w w Z O z K a w a m w CHECKED BY: 02/02/2011 ISSUE DATE: Copyright © 2009 - A I right reserved Architectural Engineering Design Group, Inc. All design drawings and written material herein may not be used or duplicated without the written consent of Architectural Engineering Design Group, Inc. SHEET NO.: E0.0 Feb 02, 2011, 1 :• 03pm W cb W 0 Architectural Engineering Design Group, Inc. J. SIGNAL REFERANCE GRID (SRG) GROUNDING SYSTEM. REFER TO DETAIL #1/E1.2 TO (N) 2'X2' GRID UNDER RAISED FLOOR GROUND CLAMP EVERY 3RD AND /OR 6111 PEDESTAL ) 1 • BOND TO BLDG. STEEL (12 BARE STRANDED). 2. BOND TO EQUIPMENT RACKS ( #2 BARE STRANDED). 3• BOND TO FLOOR PANELBOARDS ( #2 BARE STRANDED). 4• BOND TO UNDERFLOOR METALIC PIPING (02 BARE STRANDED). 5. BOND TO HVAC EQUIPMENT (#6 BARE STRANDED). 24" >(F) PDU FUTURE CONN. >(F) PDU- FUTURE CONN. (E ) PDU (E) PDU 0 °0 0 0 0 0 0 0 0 0 �ti 0. 0• 0010‘ 0 0 0 0 0 0 0 0 0 0 (N) 'SRG - GND -1' 1/4 "X4 "X 12" BARE CU BUS (GENERATOR ROOM) BOND ENCL AND GEN FRAME (E) 'G1' BOND ENCL N -G RESISTOR AND GEN FRAME (N) 'G2' l 750kcmil 750kcmil 4, (N) 'MGB' 1/4- A amuanaau0 0 0 o 0 0 0 0 0 0 0 0 0 750kcmil #4/0 TO (E) FIBER OPTIC CABLE ROOM GROUND BAR (IF AVAILABLE AT SITE) #750kcmil TRANSFORMER N -G BOND (E) DRY -TYPE TRANSFORMER (2500KVA) #4/0 #4/0 •TRANSFORMER N -G BOND (E) DRY -TYPE TRANSFORMER TXG -1 - TRANSFORMER N -G BOND (E) DRY -TYPE TRANSFORMER TXG -1 CADWELD (E) GROUND ROD FOR EARTH GROUND (TYP,) ONLY USED IF 3 OH IMPEDANCE IS NOT ACHEIVED SIGNAL REFERANCE GRID (SRG) GROUNDING SYSTEM. REFER TO DETAIL #1/E1.2 TO (N) 2'X2' GRID UNDER RAISED FLOOR GROUND CLAMP EVERY 3RD AND /OR 6TH PEDESTAL • s 1. BOND TO BLDG. STEEL ( #2 BARE STRANDED). 2. BOND TO EQUIPMENT RACKS ( #2 BARE STRANDED). 3• BOND TO FLOOR PANELBOARDS ( #2 BARE STRANDED). 4. BOND TO UNDERFLOOR METAUC PIPING ( #2 BARE STRANDED). 5. BOND TO HVAC EQUIPMENT ( #6 BARE STRANDED).. 750kcmil 750kcmil 24" r^ 00 0 0 0 0 0 0 0 0 0 0 0 0 0 • 0 •�o 0• 0 o�o o o 0 0 0 (N) 'SRG - GND -2' 4" >(F) PDU- FUTURE CONN. "(F) PDU - FUTURE CONN. (E) PDU (E) PDU 24" 0 0 000 0 0 0 0 0loo 0 0 0• 0 000 0 0 0 0 0 0 0 (N) 'OPGB' 750kcmil 750kcmil 750kcmil 750kcmil 750kcmil 750kcmil 750kcmil GROUNDING ELECTRODE CONDUCTOR 1750kcmil GROUNDING CONDUCTOR 15' (TYP.) - POLYESTER INSULATOR (6) & /LOCKWASH RS °;;;;7r- GROUND BAR ' ('TMGB' OR TYPICAL) MOUNTING BRACKET DATA CENTER WALL / 2 l GROUND BAR MOUNTING SCALE: NONE • • f750kcmil GROUNDING ELECTRODE CONDUCTOR TIT • • GROUNDING Lo ELECTRODE CONDUCTOR AWG IICAL) SWBD N #750kcmil I750kcmil GROUNDING ELECTRODE CONDUCTOR �f :I is PER NEC 250.24(A)(4) ViG IICAL) SWBD G PER NEC 250.24(A)(4) (1Y %VGR OR SWBD IICAL) Gl \- PER NEC 250.24(A)(4) (E) DOMESTIC WATER (E) FIRE PROTECTION SERVICE. RISER. (E) BUILDING STEEL GROUNDING ONE -LINE DIAGRAM (E) MECHANICAL EQUIPMENT FRAMES > (E) MISC. EQUIPMENT FRAMES > (E) AC CABLE TRAY (IF APPUCABLE) RE: #4/E1.0 00 0 0 0 0 0000 0 O 0 0 O 0 0 0 1/4 "X4 "X24" BARE CU BUS (N) AC -GND TO (E) UFER GROUND CONNECTIONS SCALE: NONE "� o 0 0 4 I 1 0 0 0 2" I ' 2 O 0 0 0 0 0 O 0 0 0 0 0 2" (TYP) 9/16 110 (TYP. ) -1/8" O 0 0 ' 17 /8r O o oT 1 �16r� OF • (�T 1 2) 1 3/4" 36" PREFERED MEIF 1. ALL HOLES ARE COUNTERSUNK 1/16". 2. BAR STOCK 15 1/4" THICK, 98% CONDUCTIVE COPPER. 3. TIN PLATE 0.0003" TYP. (0.0002" MIN.) THICK. TMGB GROUND BAR DETAIL SCALE: NONE 5/8" DIA THREADED ROD MIN. LOCK NUT LOCK NUT 14/0 COLD GND 4" (E) UPS 'U1 UPM -1' (E) UPS 'U1 UPM -2' (N) UPS 'UPS -A' (N) UPS 'UPS -B' (N) TMGB (ALL DC PLANTS PROVIDING SERVICE TO THE AREA COVERED) (IF AVAILABLE AT SITE) N o�o`onoElo 0 0 Li o 0 0 00 0 0 0 0 0 0 0 0 0 0 0 00 0 GENERAL NOTES: 1. THE INSTALLED GROUND SYSTEM SHALL BE REQUIRED TO ACHIEVE A RESISTANCE OF NOT MORE THAN 3 OHMS. WHERE MINIMUM RESISTANCE CANNOT BE ACHIEVED USING THE GROUNDING ELEMENTS SHOWN, THE CONTRACTOR SHALL ADD ADDITIONAL GROUND RODS OR PROVIDE GROUND ENHANCING MATERIALS UNTIL LESS THAN 3 OHM GROUND RESISTANCE IS MET. 2. EXTENSION CONDUCTORS SHALL BE A MINIMUM OF #4/0 GREEN INSULATED WITH PIPE CHOAKS. 3. GROUND RING CONDUCTORS SHALL BE A MINIMUM OF 3' -0" FROM CONCRETE FOUNDATIONS AND A MINIMUM OF 30" BELOW GRADE. 4. GROUND SYSTEM RING SHALL BE A MINIMUM OF #3/0 BARE, BRADED COPPER CABLE. 5. CONNECTIONS MADE. TO THE PERIMETER GROUND RING SHALL TAKE PLACE AT GROUND ROD LOCATIONS, UNLESS OTHERWISE NOTED. 6. BURIED GROUND CONNECTIONS SHALL BE MADE BY EXOTHERMIC WELD. 7. THE INSTALLED PERIMETER GROUND RING SHALL NOT BE BACKFILLED UNTIL AFTER INSPECTION. ▪ RAISED FLOOR GRID SYSTEM SHALL BE IN COMPUANCE WITH LOCAL JURISDICTIONAL CODES AND PER IEEE STANDARD 142/1100. 9. FRAME = RACK /CABINET. EQUIPMENT - CUSTOMER EQUIPMENT (BAR). 10. 14/0 MINIMUM WITH LARGER CONDUCTOR SIZE TO BE DETERMINED BY CONDUCTOR LENGTH UP TO 750KcMIL 1/4 "X4"X30" BARE CU BUS (DCB: ALL BDFB'S PROVIDING SERVICE TO THE AREA COVERED), RE: 11/E1.1 'I' SECTION NOT TO BE USED. #4/0 BDFB FRAME GND 14/0 BDFB FRAME GND #4/0 BDFB FRAME GND 1750 DC POWER RETURN BUS UNISTRUT CONCRETE INSERT CAST IN SLAB OR USE RAMSET THREADED STUDS 1111■,■•, 11. 11'11'11'11'11'11.41111 CABLE TRAY 2' O.C. MAX HQE@ (IF AVAILABLE AT SITE) BEER (IF AVAILABLE AT SITE) MEd (IF AVAILABLE AT SITE) DC RECTIFIER BAY (IF AVAILABLE AT SITE) MEDIA OUTPUT AND ASSOCIATED CABLE TRAY MAY NOT BE USED /AVAILABLE AT EACH SITE (CONFIRM WITH COREUNK ENGINEERING) CABLE TRAY SHALL BE A MINIMUM OF 12" HORIZONTALLY FROM BAR 1 7'-6" MIN TO FINISHED FL / + l MAIN AISLE LADDER RACK SCALE: NONE s X4 /0 COLO GND RE: f4 /E1.0 DISTANCE O - 100' 101 - 150' > 151' CABLE SIZE 11 AWG #2 AWG #2/0 AWG REVIEWED C EWTH NFPA70 • NEC FEB 16 2011 V /� 0 81 q REB EI QED PERMIT CENTER ce LIJ V Z Z= W < U � Lu u Z °-= O W L.tL O 17- M a 0 DESCRIPTION 0 N ce a w Z 0 w w Ca w CHECKED BY: 0 N O_ 0 ISSUE DATE: Copyright © 2009 - Alright reserved Architectural Engineering De Ign Group, Inc. All design drawings and written material herein may not be used or duplicated without the written consent of Architectural Engineering Design Group, Inc. u < Z (/1 up2 Z d u 0 J a W u 0 SHEET NO.: E1.0 Feb 02, 2011, 1.03pm k czi LLJ W W c ob 0 U Architecture/ Engineering Design Group, Inc. ✓: CONDUIT INPUT FEEDER CONTAINED IN METAL CONDUIT. 3-I IRE +G AS SHOWN. FROM AC SUPPLY AC SYSTEM GROUNDING ELECTRODE CONDUCTOR REFER. NEC 645-15 CONNECTION KEY 0 0 SDBC (16 MM 2 ) 2O p SDBC (35 MM2 ) 0 p SDBC (35 MM2) O4 #4/0 SDBC (95 MM2 ) O LOW IMPEDANCE RISER RAISED FLOOR GROUNDING DIAGRAM (TYPICAL) SCALE: NONE TYPICAL DEDICATED ISOLATION TRANSFORMER EQUIPPED WITH ELECTROSTATIC SHIELDS A DELTA PRIMARY (INPUT) AND A WYE CONNECTED SECONDARY (OUTPUT) X1 EUT./GND. UNE -1 JUMPER X2 VINE -2� Z NEUTRAL G UNE -3— IG SYSTEM GROUND MECHANICAL CONNECTION TO FRAME EQUIPMENT FLOOR OUTPUT FEEDER CONTAINED IN METAL CONDUIT. 4-1 IRE +G +IG AS SHOWN. ALL CONDUCTORS MUST BE CARRIED IN THE SAME CONDUIT AND CAN ONLY BE TERMINATED WITHIN THE EQUIPMENT THE OUTPUT FEEDER IS SERVING. TO LOAD SOLIDLY GROUND/BOND ALL CONDUITS TO THE METAL ENCLOSURE OF 1HE TRANSFORMER IN ALL CASES. DO NOT USE INSULATION '- ENCLOSURE/FRAME OF TRANSFORMER STATIC GROUND (RE #i/E1.1) /0 GROUNDING ELECTRODE TO MGB (RE #1/E1.0) MECHANICAL CONNECTION • EXOTHERMIC WELD � 2 � ISOLATION TRANSFORMER WIRING SCHEMATIC LOCK WASHER APPLY —\ NO -OX SCALE: NONE #6 AWG PIGTAIL BUS BAR FLAT WASHER EQUIPMENT CHASSIS EQUIPMENT FRAME GROUND ON FRAME FRAME GROUNDING CONNECTIONS SCALE: NONE 1 BUILDING STEED DETAIL NOTES: � s l STA11C GROUND SHALL BE 6' Y DE AND USE #6 BARE COPPER STRIPS (200LF MAX). SMALLER CONDUCTOR LENGTH OK . 2' X 2' RAISED FLOOR ACCESS PANELS. EVERY 6th (MAX) RAISED FLOOR SUPPORT PEDESTAL IN EACH DIRECTION SHALL BE CONNECTED TO THE LOOPED GRID USING A #13 SOFT DRANK BARE COPPER (SDBC) CONDUCTOR. THE CONNECTION TO THE PEDESTAL AND THE GRID SHALL BE EXOiHERMICALLY WIELDED. THE CONNECTION TO THE PEDESTAL SHALL BE MADE ABOVE THE JACK SCREW. LOOPED GRID TO BE INSTALLED AT RAISED FLOOR LEVEL. ALL BUILDING STEEL, CONDUITS, RACEWAYS, CABLE TRAYS, WATER PIPES, CRAC UNITS, DUCTS, AND OTHER METALLIC ITEMS ENTERING THE GRID AREA SHALL BE BONDED TO THE 1MGB AND BUILDING STEEL ALL OF THESE INMES ROUTED HORIZONTALLY SHALL BE BONDED AT BOTH ENDS. PROVIDE #750Kcml TO MGB. REFER TO GROUNDING ONEUNE DIAGRAM #1/o.0. BOND THE RAISED FLOOR SUPPORT SYSTEM TO BUILDING STEEL AT THESE LOCATIONS IN OR NEAR THE DATA CENTER. RACKS, CONSOLES AND ALL ELECTRONIC EQUIPMENT ENCLOSURES SHALL BE BONDED TO THE 'COLO -GNO' AT THE CLOSEST AVAILABLE POINT VIA ONE LOW IMPEDANCE RISER (UR) TO EACH RACK, CONSOLE OR ELECTRONIC EQUIPMENT. REFER TO DETAIL 13/E1.1 FOR DETAIL CONNECT THE #4/O GROUND CONDUCTOR TO '1MGB1 . CONNECT EACH EQUIPMENT CABINET TO THE COLD -GND. ALL CABLE TRAY SHALL BE MADE CONTINUOUS BY USING A FLAT WASHER AND A SPUT WASHER %NTH THE ASSEMBLY TED TO THE OUTSIDE OF THE CABLE TRAY ((COL PRESSURE CONNECTION. CONDUCTOR S A SHALL BE CONNECTED TO BOTH SIDES OF ANY JOINT. THIS CONDUCTOR SHALL ORIGINATE AND BE ROUTED ON THE MAIN RUNS OF THE SUITE WITH BRANCH FEEDERS. IF REQUIRED, H -TAPED TO MAIN. CONNECT ALL CONDUIT AND PIPING TO THE 'TMGB' USING PIPE GROUND CLAMPS AND #6 STRANDED BARE COPPER CONDUCTOR. LADDER RACK (NOT FOR DC CABLE) STAINLESS STEEL WORM GEAR CLAMP • EXOTHERMIC WELD REMOVE PAINT AND TREAT SURFACE WITH A THIN COAT OF NO -OX -ID 'A' 0:4 SINGLE CRIMP, DOUBLE HOLE, INSULATED LUG #6 AWG PIGTAIL IF A BOLT IS USED, A WASHER AND NUT IS REQUIRED ON INSIDE OF FRAME WORK EQUIPMENT RACK GROUNDING DETAIL SCALE: NONE FURNISH AND INSTALL A 14/0 GREEN ON THE EXTERIOR OF THE CABLE TRAY. FASTEN THIS CONDUCTOR TO THE EXTERIOR OF THE CABLE TRAY AT EACH J -HOOK AND NUM #9 WAXED CORD 10 ATTACH CONDUCTOR TO CABLE TRAY AND L- BRACKETS. REFER TO DETAIL 14/E1.0. FURNISH AND INSTALL A 14/0 GREEN CONDUCTOR BETWEEN THE CABLE TRAY AND THE TMGB. THE 14/0 CONDUCTOR SHALL BE CONTINUOUS (LONG SWEEPING CURVATURE) FROM THE EXTERIOR OF THE CABLE TRAY TO THE GROUND BAR AND BE MECHANICALLY CONNECiTED TO THE TMGB GROUND B. THE CABLE TRAY SHALL BE ASSEMBLED USING A FLAT WASHER AND A SPUT LOCK WASHER WiTH THE ASSEMBLY HARDWARE TO PROVIDE A HIGH PRESSURE, LOW RESISTANCE CONNECTION. NOT USED. CONNECT A #6 COPPER CONDUCTOR TO THE EQUIPMENT RACK FRAME BY H- TAPPING OR CRIMPING. THE LENGTH OF THE #6 SHALL BE KEPT AS SHORT AS POSSIBLE WITH A NICE SWEEPING CURVATURE USE AN ANTI -OXIDANT PASTE (NO -OX) AT THE POINT BOWEEN 1HE WIRE AND THE EQUIPMENT RACK. SECURE THE #6 CONDUCTOR TO THE RACK WiTH TWO HOLE BOLTED CONNECTION WITH LOCK WASHERS BETWEEN THE MOUNTING SCREWS AND LUG. REFER TO DETAIL 15/E1.1 FOR BOLTED CONNECTIONS DETAIL PROVIDE #750Kcmil TO THE MGB. REFER TO GROUNDING ONELJNE DIAGRAM #1/E1.0. #6 GROUNDING STRAP CONNECTION AT CABLE TRAY JOINT. PROVIDE LOCK WASHERS FOR BOLTED CONNECTION. APPLY N0-OX AT TRAY JOINT CONNECTION. EXOTHERMIC WELD RAISED FLOOR PEDESTAL //- J-HOOK CABLE SUPPORT. ATTACH TO EVERY OTHER PEDESTAL, FASTEN CABUNG WA1H 11E WRAPS NYLON 1IE WRAPS (TYPICAL) UNISTRUT SUPPORT STEEL SHALL ALSO BE WELDED TO THE ADJACENT RAISED FLOOR PEDESTAL • MECHANICAL CONNECTION EXOTHERMIC WELD STA11C GROUNDING STRINGER INTERFACING UNDER RAISED FLOOR SCALE: NONE THIS IS THE 'TYPICAL METHOD OF LAYING -IN A METALLIC CONDUIT OR TRUNKING CONTAINING ELECTRICAL WIRING. THE TYPICAL APPLICATION IS FOR CONDUITS, TRUNKING, ETC. CROSSING OVER THE GROUNDING STRINGER. THIS IS A TYPICAL VERTICAL PEDESTAL POST USED TO SUPPORT THE RAISED FLOOR'S SURFACE THE POST 15 USED AS AN ELECTRICAL PATH BETWEEN CONNECTED ITEMS ABOVE AND BELOW. THE JOINT MUST BE JUMPERED/BONDED ACROSS USING #6 CONDUCTOR. MOST JOINTS ARE ONLY HELD TOGETHER BY GRAVITY AND THEREFORE DO REQUIRE SUCH JUMPERING/BONDING. REFER TO ELECTRICAL DETAIL 13/E1.1 DETAILED NOTE #6. UNISiRUT IS USED AS THE PRINCIPAL GROUNDING BUS -BAR AND MECHANICAL SUPPORT MEANS AS SHOWN. IT IS AN EXCELLENT MATERIAL TO USE FOR THIS PURPOSE. WELDING IS THE PREFERRED MEANS OF JOINING THE UNISTRUT TO THE RAISED FLOOR'S PEDESTAL AS SHOWN (AT EACH END, OR WHEREVER THE UNISTRUT CROSSES OR ENDS AT A PEDESTAL AS SHOWN). 0081 REVIEWED Fu COMPLIANCE WITH NFPA 70 - NEC FEB 16 2011 City of BUILDING DIVISION iSION RECEIVED FEB 03 2011 PERMIT CENTER 1 N W X E to 0 U d LL � * 0 > .00 d'rn C =moo Cri en N m M O1 - 0 t0 tD w 00101 d N M M c y >OO y > M N w 0 0 rn 0 w Q 0 DESCRIPTION w o z vi O Z G 0 w Q CO w CHECKED BY: 0 N_ 0 Z O Z =w Z O 00 ISSUE DATE: Copyright © 2009 - A I right reserved Architectural Engineering De Ign Group, Inc. All design drawings and written material herein may not be used or duplicated without the written consent of Architectural Engineering Design Group, Inc. V < Z v� u Z g U 0 V J Q w L SHEET NO.: E1.1 Feb 02, 2011, 1 :• 04pm Architectural Engineering Design Group, Inc. J. 1 1775.01 - Core /ink Seattle lI 1Elec 1E12 - ELECTRICAL GROUNDING DRAWINGS. dwg CONNECTION KEY O1 #6 SDBC (16 MM 2 ) 0 #4 SDBC (25 MM2 ) 0 12 saw (35MM2) 0 0/O SDBC (95 MM2 ) ® LOW IMPEDANCE RISER BUILDING STEED f- PDU AND /OR PMR (ISOLATED EQUIPMENT FRAMES) PANELBOARD =..vasaow._ ®TRANSFORMER 1j ► •••• 4> IWO* -.416t1* -14*01 rW000.) .ail *A � rt � — — — CONDUIT 6' -0' 1800 MM OR LESS ELECTRONIC EQUIPMENT RACKS—\ 1 SIGNAL REFERENCE GRID (SRG) DIAGRAM E1.2 SCALE: NONE .u. MIRE FED WELD • MECHANICAL CONNECTION • EXOTHERMIC WELD SIGNAL REFERENCE GRID (SRG) SIGNAL CABLES RAISED FLOOR PEDESTAL GALVANIZED STEEL LADDER CABLE TRAY 2 � SRG RAISED FLOOR GROUNDING DETAIL SCALE: NONE DETAIL NOTES ( #2/E1.2): FURNISH AND INSTALL A #4 (25 M1A2) SOFT—DRAM BARE COPPER CONDUCTOR (SDBC) ON THE EXTERIOR OF THE CABLE TRAY. FASTEN THIS CONDUCTOR TO THE EXTERIOR OF THE CABLE TRAY AT ONE METER INTERVALS WITH NYLON SELF—LOCKING TIE WRAPS. NE 25MM2 CONDUCTOR SHALL BE EXOTHERMICALLY WELDED ON BOTH SIDES OF ALL CABLE TRAY JOINTS. FURNISH AND INSTALL A 114 (25 MM2) SDBC CONDUCTOR BETWEEN NE CABLE TRAY AND ANY BUILDING STEEL OR UGH NING PROTEC11CN DOWN CONDUCTOR WITHIN SIX FEET (1,600 MM) OR LESS OF THE CABLE TRAY. THE 25MM2 SDBC CONDUCTOR SHALL BE EXOTHERMICALLY WELDED BETWEEN THE 25 IMM2 SDBC CONDUCTOR ON THE EXTERIOR OF THE CABLE TRAY AND THE BUILDING STEEL ALL OPEN BOTTOM TYPE LADDER CABLE TRAYS SHALL HAVE 22 —GAUGE GALVANIZED SHEET STEEL LAID IN THE BOTTOM OF THE TRAY AND WELDED TO THE TRAY EVERY METER. IF SOLID BOTTOM CABLE TRAY IS USED THEN THE 22 —GAUGE GALVANIZED SHEET STEEL IS NOT REQUIRED. THE CABLE TRAY SHALL BE ASSEMBLED USING A FLAT WASHER AND A SPLIT LOCK( WASHER WITH THE ASSEMBLY HARDWARE TO PROVIDE A HIGH PRESSURE. LOW RESISTANCE CONNECTION. A 22 —GAUGE GALVANIZED SHEET STEEL STRIP SHALL BE USED TO IRANSI1 O N YIN THE SIGNAL CABLES FROM THE CABLE TRAY TO THE ELECTRONIC EQUIPMENT RACK. THE SHEET STEEL STRIP SHALL BE AT LEAST ONE FOOT WIDE NE STRIP SHALL BE FASTENED TO THE CABLE TRAY AND THE RACK 11I1H POP RIVETS AT THREE LOCATIONS. FURNISH AND INSTALL TWO LOW IMPEDANCE STRAPS (UR) FROM EACH ELECTRONIC EQUIPMENT RACK TO THE SRG. THE UR SHALL BE BOLTED TO THE ELECTRONIC EQUIPMENT RACK FRAME AND EXOTHERMICALLY WELDED TO THE SRG THE LENGTH OF UR SHALL BE KEPT AS SHORT AS POSSIBLE YM1H A NICE SWEEPING CURVATURE. EXOTHERMICALLY WELD A #6 (16 MM2) SDBC CONDUCTOR TO THE SRG AND RAISED FLOOR PEDESTAL BASE EXTEND THE BASE END OF THE #6 CONDUCTOR UP THE PEDESTAL AND ACROSS NE JACK( SCREW. BOND THE 16 CONDUCTOR TO THE UPPER PORTION OF THE PEDESTAL WITH A STAINLESS STEEL NORM GEAR TYPE CLAMP. USE AN ANTI — OXIDANT PASTE AT THIS POINT BETWEEN THE WIRE AND THE PEDESTAL SECURE THE #6 CONDUCTOR TO THE PEDESTAL WITH SELF— LOCKING NYLON TIE WRAPS EXOTHERMICALLY WELD A #6 (16 MM2) SDBC CONDUCTOR TO 1HE SRG AND EXPOSED BUILDING STEEL AT THREE LOCATIONS INPUT FEEDER CONTAINED IN METAL CONDUIT. 3 -MARE +G AS SHOWN. FROM AC SUPPLY AC SYSTEM GROUNDING ELECTRODE CONDUCTOR REFER. NEC 645-15 WATER PIPE TYPICAL DEDICATED ISOLA11CNN TRANSFORMER EQUIPPED WITH ELECTROSTATIC SHIELDS A DELTA PRIMARY (INPUT) AND A WYE CONNECTED SECONDARY (OUTPUT) X1 ELT. /GND. LINE -1 JUMPER UNE -2 7_ NEUTRAL UNE -3 -0- G IG DETAIL NOTES ( #1 /E1.2): THE SIGNAL REFERENCE GRID (SRG) SHALL BE 2" WIDE BY .0159' THICK COPPER STRIPS ON 2 FOOT CENTERS. THE PRODUCT SHALL BE MANUFACTURED BY ERICO ELECTRIC PRODUCTS OR APPROVED EQUAL THE SRG SHALL BE INSTALLED CN THE CONCRETE FLOOR UNDER COREUNK SPEOF1C RAISED FLOOR AREAS. THE SRG SHALL BE INSTALLED PER THE MANUFACTURER INSTALLATION INSTRUCTIONS. ALL CROSSOVERS OF THE SRG AND CONNECTION TO THE SRG SHALL BE MADE BY THE EXOTHERMIC WELDING PROCESS. EVERY 6th RAISED FLOOR SUPPORT PEDESTAL IN EACH DIRECTION SHALL BE CONNECTED TO THE SRG USING A 16 SOFT DRAWN BARE COPPER (SDBC) CONDUCTOR. THE CONNECTION TO THE PEDESTAL AND THE SRG SHALL BE EXOTHERMICALLY WELDED. THE CONNECTION TO THE PEDESTAL SHALL BE MADE ABOVE THE JACK SCREW. REFER TO ELECTRICAL DETAIL #4/E1.1. ALL BUILDING STEEL, CONDUITS, RACEWAYS, CABLE TRAYS, WATER PIPES, DUCTS. AND OTHER METALLIC ITEMS ENTERING THE GRID AREA SHALL BE BONDED TO THE SRG. ALL OF THESE ITEMS ROUTED HORIZONTALLY SHALL BE BONDED AT BOTH ENDS. NEVER CONNECT ELECTRONIC EQUIPMENT TO THE OUTER STRIP OF THE SRG. CONNECT ELECTRONIC EQUIPMENT AT LEAST 6' —O' INSIDE THE SRG. CONNECT ALL BUILDING STEEL, CONDUITS, RACEWAYS, CABLE TRAYS, WATER PIPES, DUCTS, AND OTHER METALUC ITEMS TO THE OUTER STRIP OF THE SRG AT THEIR ASSOCIATED INCOMING OR OUTGOING PENETRATION POINT. BOND THE SIGNAL DICE GRID TO SRG —GND AT THIS LOCATION IN OR NEAR THE RAISED FLOOR SPACE. RACKS, CONSOLES AND AU. ELECTRONIC EQUIPMENT ENCLOSURES SHALL BE BONDED TO 1HE SRG AT THE CLOSEST AVAILABLE POINT VIA TWO LOW IMPEDANCE RISER (UR) TO EACH RACK, CONSOLE OR ELECTRONIC EQUIPMENT. REFER TO DETAIL #3/E1.1. PROVIDE #750Kcmil TO MGB. REFER TO GROUNDING ONEUNE DIAGRAM #1/E1.O. CONNECT EACH PDU, PMR, OR PANELBOARD TO THE SRG. • ALL CABLE TRAY SHALL BE MADE CONTINUOUS BY USING A FLAT WASHER AND A SPOT WASHER VAN THE ASSEMBLY HARDWARE TO FORM A LOW IMPEDANCE PRESSURE CONNECTION. A 14/0 CONDUCTOR SHALL BE ATTACHED TO THE OUTSIDE OF THE CABLE TRAY EVERY 3 FEET WITH NYLON 116. THE CONDUCTOR SHALL BE CONNECTED TO BOTH SIDES OF ANY JOINT. THIS CONDUCTOR SHALL ORIGINATE AND TERMINATE AT THE SRG AND BE ROUTED VAIN EACH CABLE TRAY THAT BRANCHES OFF THE MAIN RUN. CONNECT ALL CONDUIT AND PIPING TO THE SRG USING PIPE GROUND CLAMPS AND 16 STRANDED BARE COPPER CONDUCTOR. ® REFER TO ELECTRICAL DETAIL #2/E1.1 FOR PROPER WIRING AND GROUNDING OF A TRANSFORMER. ® CONNECT THE IG BAR OF ISOLATED FROM PDU CHASSIS) TO THE 1' PORTION OF THE MGB. REFER TO GROUNDING ONEUNE DIAGRAM #1/E1.0. OUTPUT FEEDER CONTAINED IN METAL CONDUIT. 4-1 IRE +G +IG AS SHOWN. ALL CONDUCTORS MUST BE CARRIED IN THE SAME CONDUIT AND CAN ONLY BE TERMINATED WITHIN THE EQUIPMENT THE OUTPUT FEEDER IS SERVING. SYSTEM GROUND SYSTEM GROUND `"----MECHANLCAL CONNECTION TO FRAME TO LOAD SC IDLY GROUND/SCND ALL CONDUITS TO THE METAL ENCLOSURE OF THE TRANSFORMER IN ALL CASES. DO NOT USE INSULATION '— ENCLOSURE/FRAME OF TRANSFORMER ar /4 (TYR) SIGNAL REFERENCE GRID (SRG) • MECHANICAL CONNECTION • EXOTHERMIC WELD 3 ISOLATION TRANSFORMER WIRING SCHEMATIC SCALE: NONE L(OO8' cl REVIEWED rust COMPLIANCE WITH NFPA70 -NEC FEB 16 2011 City of Tukwila BUILDING DIVISION RECEIVED FEB 03 2011 PERMITCENTER LL O L LI I- Z Z= `,=c) W U EI Ce W O U DESCRIPTION w o Z Lt-; O Z N. G J S a v, 0 w CO w w CHECKED BY: 0 N 0 O N ISSUE DATE: 0 V W z0 00 Copyright © 2009 - A I right reserved Architectural Engineers g De Ign Group, Inc. All design drawings and written material herein may not be used or duplicated without the written consent of Architectural Engineering Design Group, Inc. SHEET NO.: E1.2 N PANEL 'LA' VOLTAGE L -L: 208 LOCATION: MECH/ELEG. 114 VOLTAGE L-G: 120 BUS RATING: 400 AMP TYPE: 3PH /4IN MAIN CB: 225A CB MOUNTING: SURFACE S.G. RATING: IOK AIG FULLY RATED NOTES: EXISTING PANEL FED FROM: PANEL HA VIA TXGI CIR. NO GGT TYPE LOAD VA LOAD DESCRIPTION CIRCUIT BRKR BUS CIRCUIT BRKR LOAD DESCRIPTION LOAD VA CGT TYPE GIR NO POLE TRIP TRIP POLE I R 1260 RECEPTACLES 1 20 A 1 20 GEN I BATTERY CHARGER 100 E 2 3 E 500 SF-2 1 20 B 1 20 CHILLER ISOLATION VALVE 100 E 4 5 7 4- R E 1260 100 SPARE RECEPTACLES SIEMENS CONTROLS 1 I 1 20 20 20 C A B 2 -- 2 20 20 OEN I SPACE HEATER - - 600 600 600 E 6 E E 8 10 GEN I JACKET HEATER II 1 1 20 20 SPARE 1 20 G -- -- - 600 E 12 13 15 17 R R R 1260 1260 1260 RECEPTACLES RECEPTACLES RECEPTACLES 1 1 1 20 20 20 A B G 1 I 1 20 20 20 SPARE SPARE SPARE 15 M 14 16 18 lq -- -- SPARE 1 20 A 1 20 SPARE 17 I9 M 20 21 -- 1 -- 30 SPARE 1 20 B 1 20 SPARE A 1 22 23 25 21 SPARE SPARE 1 1 20 20 G A 1 I 20 20 SPARE SPARE 20 GEN. 2 HEATER 24 26 27 22 23 SPARE 1 20 B 1 20 SPARE -- -- 28 2q 24 25 SPARE 1 20 G I 20 GEN I BATTERY CHARGER 100 E 30 31 33 26 27 SPARE SPARE 1 1 20 20 A B B BUSSED SPADE SUSSED SPAGE 32 BUSSED SPACE 34 35 BUSSED SPACE C BUSSED SPACE 36 37 BUSSED SPACE A BUSSED SPACE 38 3q 41 BUSSED SPACE BUSSED SPACE B C BUSSED SPADE BUSSED SPACE 40 42 35 CGT TYPE: L= LIGHTING, R= RECEPTACLE, M= MOTOR, LM= LARGEST MOTOR, E= EQUIPMENT, KE =KITGH EQUIP, S= SUBFEED PANEL GGT TYPE: LOAD MOLT DEMANDED LOAD LIGHTING: 0 1.25 0 VA RECEPTACLE: 6300 1.0 6300 VA OVER 1OK: 0 0.5 0 VA MOTOR: 0 1.0 OVA LGST MOTOR: 0 I.25 0 VA EQUIPMENT: 3300 1.0 3300 VA KITGH EQUIP: 0 0 0 VA SUBFEED PNL: 0 1.0 0 VA TOTAL CONNECTED LOADS A B G VA 4480 2560 2560 TOTAL DEMANDED LOADS A B C. VA 4480 2560 2560 AMPS 37 21 21 TOTAL ON 10 KVA PANEL: 27 AMPS NOTES: 'CIRCUIT BREAKERS SHOWN IN GRAY ARE EXISTING TO REMAIN. PANEL 'HA' VOLTAGE L -L: 480 LOCATION: MECH/ELEG. 114 VOLTAGE L-6: 211 BUS RATING: 400 AMP TYPE: 3PH/4414 MAIN GB: 225A C8 MOUNTING: SWAGE S.G. RATING: IOK AIC FULLY RATED NOTES: EXISTING PANG. FED FROM: PANEL HA VIA TXGI GIR. NO CGT TYPE LOAD VA LOAD DESCRIPTION CIRCUIT BRKR BUS CIRCUIT BRKR LOAD DESCRIPTION LOAD VA CGT TYPE GIR NO POLE TRIP TRIP POLE 3 L 3000 EXTERIOR LIGHTS IN SPARE 1 1 30 20 A B I 1 20 20 LIGHTS LIGHTS 1500 1500 L L 2 4 5 L 3000 EXTERIOR LIGHTS S. 1 20 G 1 20 LIGHTS 1500 L 6 7 SPARE 1 20 A 1 20 LIGHTS 1500 L 8 q II SPARE SPARE 1 1 20 20 B G I 1 20 20 LIGHTS LIGHTS 1500 1500 L L 10 12 13 M 2000 EE -5 3 30 A 1 20 LIGHTS 1500 L 14 15 M 2000 -- -- -- B 1 20 SPARE 16 17 I9 M 2000 -- SPARE -- 1 -- 30 G I 20 SPARE 18 20 A 1 20 SPARE 21 BUSSED SPAGE B 3 20 GEN. 2 HEATER 4000 E 22 23 BUSEED SPACE G -- -- -- 4000 E 24 25 BUSEED SPAGE A -- -- - 4000 E 26 27 BUSEED SPACE B SUSSED SPAGE 28 2q BUSEED SPACE G SUSSED SPAGE 30 31 BUSEED SPACE A BUSSED SPACE 32 33 BUSEED SPACE B BUSSED SPACE 34 35 BUSEED SPAGE C BUSSED SPAGE 36 37 3q S S 4480 2560 PANEL 'LA -- 3 -- 100 -- A B BUSSED SPAGE BUSSED SPACE 38 40 41 S 2560 -- -- -- G BUSSED SPAGE 42 CGT TYPE: L= LIGHTING, R= RECEPTACLE, M= MOTOR, LM= LARGEST MOTOR, E= EQUIPMENT, KE =KITGH EQUIP, S= SUBFEED PANEL GGT TYPE: LIGHTING: RECEPTACLE: OVER I0K: MOTOR: LOST MOTOR: EQUIPMENT: KITCH EQUIP: LOAD MOLT DEMANDED LOAD 16500 1.25 20625 VA O 1.0 O VA O 0.5 0 VA 6000 1.0 6000 VA O 1.25 0 VA 12000 1.0 12000 VA O O O VA 9600 1.0 9600 VA TOTAL CONNECTED LOADS A B G VA I7g80 11560 14560 TOTAL DEMANDED LOADS , A B G VA 14855 12310 16060 AMPS 72 44 58 TOTAL ON 48 KVA PANEL: 58 AMPS SUBFEED PNL: NOTES: °CIRCUIT BREAKERS SHOWN IN GRAY ARE EXISTING TO REMAIN. DETAIL NOTES 40 EC SHALL PROVIDE 480V/3PH, 20A CONNECTION TO GENERATOR SPAGE HEATER. EC SHALL WIRE USING 3 #12, InI2G, 3/4 "G. O EC SHALL REPLACE EXISTING CONTROL WIRING FOR EXISTING GENERATOR WITH NEW CONTROL WIRING ROUTED IN I" RGS CONDUIT. EC SHALL FIELD VERIFY EXACT QUANTITY AND SIZE OF CONDUIT PRIOR TO INSTALLATION. O EC SHALL PROVIDE 120V /IPH, 20A CONNECTION TO GENERATOR BATTERY CHARGER. EC SHALL HIRE USING 2 #12, I #I2G, 3/4 "C. O EC SHALL PROVIDE 2 #10, 3/4 "G FOR NEUTRAL- GROUNDING RESISTOR. ROUTE CONDUIT AT EXISTING PIPE RACK. • PROVIDE 2 #10, 7 #14, I "C FOR LOW VOLTAGE CONTROL CABLING. ROUTE CONDUIT AT EXISTING PIPE RACK. • PROVIDE 1 BELDON 8770 -3 CONDUCTOR GABLE NOLTAGE ADJUST), I BELSON 8760 -2 CONDUCTOR GABLE (GOVERNOR CONTROL), AND 1 HELUKABEL 8IGI3 -4 CONDUCTOR GABLE (GEM MODULE CAMEOS). ROUTE IN I "G. CONDUIT SHALL BE ROUTED AT EXISTING PIPE RACK. O POWER CONDUIT SHALL ROUTE ON EXISTING PIPE RACK. 00 EC SHALL PROVIDE NEW PIPE RACK FOR NEW N-G RESISTOR CABLING TO TIE INTO EXISTING PIPE RACK. O EC/ENGINEER SHALL FIELD VERIFY EXACT LOCATION PRIOR TO INSTALLATION. O MAIN GROUNDING BOND AT COLD WATER PIPE. 4 F1 DEDICATED SERVER ROOM 1 FUTURE UPS A AND B BATTERY DISCONNECTS FUTURE SWITCHBOARD SECTIONS COLOCATI0 SERVER RO 111 EXISTING GENERATOR NEMA 3R FUSE ENGLOSU GENERATOR NEMA 3R FUSE ENCLOSURE v 11 MBP -2 MBP -I FUTURE FUTURE AIR 13 MECH / ELEC w FUTURE 1 r 0 FUTURE H EXISTING GENERATOR 2MW HA- 22,24,26 LA -30 N -G RESISTOR 1 TXMVIA VESTIBULE 115 ELECTRICAL POWER PLAN 1 1 FUTURE NEW SWITCHBOARD SECTION FOR NEW GENERATOR PANEL 'HA' PANEL 'LA' E2.0 SCALE: 1 /8" = 1' -0" 8� 10 x (N) 'TMGB -2' OR (N) 'SRG — GND -2' (N) 'AC —GND' S TAIR 13 (N) 'TMGB -1' OR (N) 'SRG — GND -1' #2 M E CEI ELEC 114 VESTIBULE 115 1 1 (N) 'OPGB' (N) 'MGB' 0 0 ii 2 ■;IP\ WA iiiii ii• (N) N —G RESISTOR 2 ELECTRICAL GROUNDING PLAN E2.0 SCALE: 1 /8" = 1' -0" REVIEINEL► .R)I COMPLIANCE WITH NFPA70 - NEC FEB 16 2011 City of Tukwila BUILDING DIVISION RECEIVED FEB 0 32011 PERMITCEITER :n fV N X E vi 0 :d 0 >LL u v O M M , D O O C m m O1 - ate,'k'� +L+ V N N G/ 0 v au 0 > M M af O O c, 1 EXPIRES c W z Z Z i W � a J HIM a� 0 W U J Z� J o W o� U 0 In nW z 0 N. z 0 w Q m w w 02/02/2011 ISSUE DATE: Copyright © 2009 - A I right reserved Architectural Engineering De Ign Group, Inc. All design drawings and written material herein may not be used or duplicated without the written consent of Architectural Engineering Design Group, Inc. J V oC I— w z W Q O J W z W z z W J Cl- SHEET NO.: E2.0 Feb 03, 2011, 5• 08pm FEEDER SCHEDULE KEY/ AMPS FEEDER CONDUIT AND CONDUCTORS KEY/ AMPS FEEDER CONDUIT AND CONDUCTORS SERVICE ENTRANCE FEEDERS SOS XFMR FEEDERS MOTE I) 400N 2[4663/0, 2 °C] 305 46610, I #86, 3/4 "G 600N 2[4#350, 3'C] 505 466, 1 *86, I -1 /4 "G SOON 2[466500, 3- I/2 "C] 1005 4*1, 1666, 1 -1/2 "C I000N 3[0400, 3- I/2 °C] 1505 4#1/0, 1#66, 2 "0 1200N 4[446350, 3'C] 2505 4 66250, I #26, 3 "C 1600N 5[40400, 3- I/2 "G] 4005 2[4463/0, I 4626, 2 "C] 2000N 046400, 3- I/2 "G] 5005 2[446250, I#1/O6, 3 "G] 2500N 1[4 66500, 3-1/2°C] 8005 21:46500, 1 *2/06, 3- I/2'Gl 3000N 8[46500, 3- I/2 "G] 10005 3[4#400, I#4/O6, 3- I/2'G] 3500N 10[46500, 3- I/2 "G] 16005 5[46400, 1#3506, 3-I/2"C] 4000N 11[4*500, 3- I/2 "G] 25005 1465500, 165006, 3- I/2'C] EQUIPMENT FEEDERS 20N6 44612, #126, 3/4 "G 206 3612, #126, 3/4 "G 30N6 44410, I #106, 3/4 "G 306 3#10, I #IOC, 3/4 "C 40N6 466, I #106, I "C 406 368, I #106, I "G 50N6' 466, I #106, I-1/4"C 50G 366, I #106, 1 °C GONG 4#4, I #IO6, I -I /4'G 606 364, I 44106, 1 °0 7ONG 464, I #86, 1 -I /4 "C 70G 364, Nee, I -1 /4 "G SONS 4463, 1#86, I -I /4'C 806 3443, I *86, I -I /4 "G gON6 4662, I #86, I -I/2'G q06 3#2, I #86, I-1/4"C IOONS 461, 1#86, I -I/2 "G 1006 361, I 4686, I -1/2'C (IONS 4#I, I#66, 2'G 1106 3#I, I*66, I -I/2 "C 125N6 4#1/0, I#66, 2 "C 1256 3441/0, 16666, I -1/2 10 15ONS 4#1/0, 1#66, 2 "G 1506 3461/0, 11666, I -I/2 "C 175N6 4#2/O, I*66, 2 "G 1756 3#2/0, I#66, 2 "C 20ON6 4463/0, 1#66, 2 -I/2 "G 2006 363/0, 1#66, 2 "C 225NG 4#4/0, I#46, 2 -I/2 "C 2256 364/0, I*66, 2 "C 250N6 4#250, (*46, 3 "C 2506 3#250, 1046, 2 -1/2 "G 300N6 446350, 1*46, 3 "G 3006 36350, 14646, 2 -I /2 "C 350N6 446500, 1#36, 3 -I/2 "C 3506 366500, I*36, 3 "C 400NG 2[463/0, I#36, 2- I/2 "G] 4006 2[3443/0, I#365, 2 "G] 450N6 2[444/0, 1 #26, 2- 1/2 "C] 4506 2[3464/0, I #2G, 2 "0] SOONG 2[46250, 1626, 3•0] 5006 2[346250, 1626, 2- I/2 "G] GOONS 2[446350, 1#16, 3 "G] 600G 2[30350, 1 #IG, 2- I/2 "G] 70ONG 2[446500, I #I /06, 3- 1 /2 "C] 7006 204500, I 441 /06, 3'G] BOONS 2[46500, 1 #1/06, 3- I/2 °G] 8006 2[36500, I *I /06, 3 "0] IOOON6 3(444400, 1 442/06, 3- 1 /2 4G] 10006 3[3#400, I412/OG, 3°C] 1200N6 4446350, 163/06, 3 °G] 12006 4[36350, 1#3 /06, 3 110] ISOONG 5[4465500, 164/06, 3- I/2 "C] 16006 5[36500, I#4/06, 3 "C] 2000N6 6[4#400, I #2506, 3- I/2 "C] 20006 6[36400, 162506, 310] GROUNDING CONDUCTORS ABBREVIATIONS 68 168, 3/4" G MESH SEE MESH SCHEDULE 66 I466, 3/4" G XFMR SEE XFMR SCHEDULE 64 I#4, 3/4" G 610 I -I /0, 3/4" C 620 1 -2/0, 3/4" C, 630 1 -3/0, 3/4" C NOTES: 1. 2. 3. FEEDER FOR SECONDARY OF SEPARATELY DERIVED COPPER MINN ON FILL RATIOS SYSTEM (SDS). GROUND SIZE PER ALL CONDUCTORS ARE SINGLE NEC 250.66. CONDUCTOR BASED NOTED OTHERWISE, GI. UNLESS NOTED OTHERWISE. AMPAG1TY NEC TABLE 310.16. ALL CONDUITS ARE EMT UNLESS BASED ON NEC ANNEX G TABLE SENERAL NOTES: I. CONTRACTOR SHALL PROVIDE PRICING FOR GENERATOR/SYNCHRONIZING SWITGHGEAR PROGRAMMING FOR IMPLEMENTATION OF NEW GENERATOR. GENERATOR SYSTEM OPERATION THE APPLIED POWER CONTROL SYNCHRONIZING SWITGHGEAR CONFIGURATION PROVIDES PARALLELING OF BOTH GENERATORS (EXISTING GATEPILLAR AND MTU). THE SYNCHRONIZING PLC BASED SWITGHGEAR (PLC DIRECT) WILL BE USED TO CONTROL THE STANDBY GENERATORS IN "LOAD SHARING" MODE. AN AUTO- OFF -TEST SWITCH SELECTS THE SYSTEM OPERATING MODES AS DESCRIBED BELOW. GENERATOR AUTO MODE WHEN AN "ENGINE START" SIGNAL 15 RECEIVED FROM AN UPSTREAM VOLTAGE SENSING OR FREQUENCY SENSING RELAY AT THE PARALLELING GEAR UTILITY MV DRAW -OUT CIRCUIT BREAKER MVI -MAIN, ENGINES IN AUTO ARE IMMEDIATELY STARTED. ONCE THE RELAYS REMOVE THE SIGNAL, THE GENERATORS WILL GO THROUGH A COOL DOWN CYCLE AND THEN BE STOPPED. LOAD SHARING. THE FOLLOWING DESCRIBES THE PARALLELING GEAR SEQUENCE OF OPERATION IN AUTO MODE: THE MASTER CONTROL PLC SENDS AN "ENGINE START" SIGNAL. THE MASTER CONTROL PLC COMMANDS THE GENERATORS TO START. ALL GENERATORS START. THE FIRST GENERATOR TO REACH RATED SPEED AND VOLTAGE WILL BE THE MTU GENERATOR AND WILL CLOSE TO THE DEADBUS. THE SECOND GENERATOR (GATEPILLAR) AND THE THIRD/FOURTH FUTURE GENERATORS THEN CONTINUE SYNCHRONIZING TO THE BUS. THE MTV GENERATOR SHALL CLOSE ITS RESPECTIVE BREAKER (GEN- BKR -2). THE THIRD AND FOURTH FUTURE GENERATOR BREAKERS SHALL FOLLOW. ALL ENGINES WILL LOAD SHARE WHILE THE "ENGINE START" SIGNAL 15 PRESENT. ONCE THE PLC REMOVES THE "ENGINE START" TO THE GENERATORS, IT WILL OPEN THE GENERATOR BREAKERS AND RUN THE ENGINES FOR THE GOOLDOWN PERIOD (10- 15 MINUTES). GENERATOR OFF MODE IN OFF MODE, AUTOMATIC OPERATION 15 DISABLED. THE BREAKER GAN BE OPENED AND CLOSED MANUALLY AT THE SWITGHGEAR. THIS 15 ESSENTIALLY A SERVICE / MAINTENANCE POSITION. GENERATOR TEST MODE PLACING ONE OF THE GENERATOR AUTO- OFF -TEST SWITCHES TO TEST SIMULATES AN "ENGINE START" SIGNAL, WHICH WILL START THE GENERATOR AND PARALLEL IT THROUGH THE SWITGHGEAR. NEXT, THE OPERATOR GAN SEQUENCE A LOAD BANK AS REQUIRED. ONE OR BOTH GENERATORS GAN BE PLACED ON THE BUS AT A TIME. AN "ENGINE START" SIGNAL FROM THE PLC WILL OVERRIDE THE TEST MODE AND OPERATE ACCORDING TO THE AUTO MODE DESCRIBED ABOVE. AFTER THE "ENGINE START" SIGNAL 15 REMOVED THE SWITGHGEAR WILL KEEP THE GENERATORS PARALLELED SINGE THE SYSTEM 15 STILL IN TEST MODE. SWITCHBOARD SHA 3000A, 480/277/, 3PH, 4W 65KAIG PROTECTIVE RELAYING FUNCTIONS PROTECTIVE RELAYING FUNCTIONS: THE FUNCTIONAL LEVELS OF PROTECTIVE RELAYING VARY WIDELY DEPENDING ON FACTORS SUCH AS: GENERATOR SIZE, POINT OF CONNECTION TO THE UTILITY AND /OR FACILITY, TYPE OF GENERATOR (INDUCTION, SYNCHRONOUS, ASYNCHRONOUS) AND STEP -UP TRANSFORMER CONFIGURATION. THE MOST UNIVERSAL MEANS OF DETECTING A L055 OF THE UTILITY 15 TO ESTABLISH AN OVER/UNDER FREQUENCY (8I ON) AND OVER/UNDERVOLTAGE (21/51) "WINDOW'[ WITHIN WHICH THE GENERATORS ARE ALLOWED TO OPERATE. WHEN THE GENERATORS ARE SUPPLYING THE LOAD INDEPENDENTLY, THE FREQUENCY AND VOLTAGE WILL QUICKLY MOVE OUTSIDE THE OPERATING WINDOW IF THERE 15 A SIGNIFICANT DIFFERENCE BETWEEN THE LOAD AND THE GENERATOR. THE FOLLOWING GENERATOR PROTECTIVE RELAYING FUNCTIONS ARE INCLUDED AT EACH MULTILIN 481 RELAY; AT THE GENERATOR SWITGHGEAR: SYNCHRONIZER GHEGK (25) - SUPERVISE CLOSING (RE- CLOSING) AS A SECURITY MEASURE TO AVOID UNSYNCHRONI ZED CLOSURE. AUTO - SYNCHRONIZER (25A) WITH VOLTAGE MATCHING - TWO MODES ARE AVAILABLE: (I) FREQUENCY AND PHASE MATCHING; AND, (2) SLIP FREQUENCY. OVER/UNDERVOLTAGE FOR GENERATOR AND UTILITY TIE (21/51) - DETECT LOSS OF PARALLEL OPERATION. OVER/UNDER FREQUENCY FOR GENERATOR AND UTILITY TIE (8I ON) DETECT LOSS OF PARALLEL OPERATION. DIRECTIONAL POWER (32) - PROTECT PRIME MOVER FROM OVERHEATING DUE TO REVERSE POWERING (REAL LOAD HIGH/LOW). FIELD/VAR (40) - PROTECT GENERATOR FROM OVERHEATING DUE TO A LOSS OF FIELD VOLTAGE (REACTIVE LOAD HIGH/LOIN). REVERSE - PHASE/PHASE - BALANCE CURRENT (46) - NEGATIVE SEQUENCE CURRENT. PROTECTS AGAINST GENERATOR ROTOR OVERHEATING DUE TO UNBALANCED PHASE CURRENTS. PHASE SEQUENCE VOLTAGE (41) - NEGATIVE SEQUENCE VOLTAGE. PROTECT AGAINST GENERATOR ROTOR OVERHEATING DUE TO UNBALANCED PHASE CURRENTS. INTERFACE REQUIREMENTS THE EXISTING TOUGH SCREEN MONITOR SHALL PROVIDE ALL SYSTEM PARAMETERS AND ALARMS. THIS DISPLAY 15 THE MASTER HMI. ENGINES GAN BE INDIVIDUALLY STARTED /STOPPED WHILE IN TEST MODE. PRESSING ANY EMERGENCY STOP BUTTON WILL STOP THAT ENGINE. (EG POWER ENGINEERING RECOMMENDS AN E -STOP FOR THE GENERATORS). EACH GENERATOR BREAKER HAS A BREAKER CONTROL SWITCH TO OPEN THE BREAKER. THE BREAKER CONTROL SWITCH ONLY ALLOWS MANUAL CLOSING OF THE BREAKER IF THE SYNC GHEGK FUNCTION IN ITS GENERATOR CONTROL PANEL 15 SATISFIED. RED, GREEN AND AMBER LIGHTS INDICATE BREAKER POSITION AND GB TRIPPED. GENERATOR SECTIONS HAVE GROUND FAULT INDICATION ONLY. A GROUND FAULT ON THE GENERATOR DOES NOT TRIP THE GENERATOR BREAKER. THE PRESENCE OF A GROUND FAULT 15 INDICATED AT THE MULTILIN 481 RELAY FOR ITS GENERATOR. GENERATOR ALARMS ARE ANNUNCIATED AT THE SWITGHGEAR. A RED LED ON THE DIGITAL DISPLAY INDICATES WHEN THE GENERATOR 15 114 ALARM. THE DISPLAY ALLOWS THE OPERATOR TO SCROLL THROUGH AN ALARM MENU TO DETERMINE THE ALARMING CONDITION AND RESET THE ALARM. THE FOLLOWING GENERATOR PROTECTIVE RELAYING FUNCTIONS ARE INCLUDED THE MTU GENERATOR CONTROL PANEL (AT THE GENERATOR): OVER/UNDERVOLTAGE FOR GENERATOR (27/51) - DETECT LOSS OF PARALLEL OPERATION. OVERNNDER FREQUENCY FOR GENERATOR (8I O/U) - DETECT LOSS OF PARALLEL OPERATION. DIRECTIONAL POWER (32) - PROTECT PRIME MOVER FROM OVERHEATING DUE TO REVERSE POWERING (REAL LOAD HI GH/LOW). FIELDNAR (40) - PROTECT GENERATOR FROM OVERHEATING DUE TO A L055 OF FIELD VOLTAGE (REACTIVE LOAD HIGH /LOW). GENERATOR OVERCURRENT (51) - TIME OVERCURRENT RELAY. PROTECTS AGAINST GENERATOR OVERGURRENTS; LOAD AND SHORT CIRCUIT. PHASE SEQUENCE VOLTAGE (41) - NEGATIVE SEQUENCE VOLTAGE. PROTECT AGAINST GENERATOR ROTOR OVERHEATING DUE TO UNBALANCED PHASE CURRENTS. SGL TRANSFORMER (BY OTHERS) 4160/2400 DELTA SECONDARY r f n 0 T MVI- TIE -GEN ' O C GENERATOR O TIE BREAKER " 2000AF • t W d GENERATOR^ II H OC. BREAKER C ' 5 ry 1200AF GEN -BKR -1 +II © r MVID 4160V DISTRIBUTION SWITGHGEAR 2000A SCOPE OF WORK UNDER THIS PHASE BUSSED FOR FUTURE CONNECTIONS GENERATOR BREAKER 1200AF GEN -BKR -2 2M - 4160 - GENE R, 20V - 4160V - GENERATOR 4160V 480/217SEC 2500 kVA GENERATOF;\ BREAKER („ 1200AF \� T FUTURE 2 MW 416OV GENERATOR MVI 4160/2400V MAIN SWITGHGEAR 2000A GENERATOR i\ BREAKER( 1200AF \I/ 2 MW 416OV GENERATOR 2000AF 2000AT • 0 N • 1 O • 0 o �! 0 • `UIUPM =2' C LOAD SUMMARY EXISTING LOAD ON SWITCHBOARD 'SHA'• NEW LOAD ON PANEL 'HA' 621 KVA 12 KVA TOTAL LOAD ON 'SHA' LOAD AT 460V/3PH 633 KVA 761 AMPS SWITCHBOARD 'SHA' IS RATED AT 3000AMPS, THEREFORE THE LOAD 15 JUSTIFIED. *EXISTING LOAD TAKEN FROM PEAK DEMAND FROM UTILITY COMPANY DURING THE LAST 12 MONTHS. CURRENT PEAK DEMAND 15 447.IKW. USING, A OR POWER FACTOR AND A 1.25 NEC FACTOR THE EXISTING LOAD 15 62IKVA. _ 2 (3 #500MGM I *I /OG IN 3 I /2 "G) UIUPM -1' 2 (3 *500MGM, I *I /OG IN 3 I /2 "G) 800A SPARE n--. 800A SPARE •" ice. UIFSO' 2500A 480V 3 (6 #500MCM, I #2506 IN 4 "G) (6) 4 "G -EACH W/ 3- 500MGM, I #2506 (3) 3 I /2 "C -EACH W/ 3- 500MCM, 3/O6 PDU PDU PDU PANEL UIDP2' P PANEL UI DPI' UISBM' 2000A, 450V SYSTEM BYPASS PDU PDU DETAIL NOTES O NEW BREAKER AND NEW SECTION SHALL BE ADDED TO EXISTING MVI GEAR. NEW GEAR SHALL TIE INTO EXISTING MVI 2000A BUSSING. REFER TO PLANS FOR LOCATION OF NEW GEAR. O REFER TO SHEET El DETAIL #1 FOR FURTHER INFORMATION ON GROUNDING FOR THIS GENERATOR. REFER TO SHEET EI.O FOR FURTHER INFORMATION FOR THE NEUTRAL TO GROUND RESISTOR. O EXISTING NEMA 3R ENCLOSURE WITH SQUARE D CURRENT LIMITING 5.0 KV 450E FUSES. O NEW NEMA 3R ENCLOSURE WITH SQUARE D CURRENT LIMITING 5.0 KV 450E FUSES. O EG SHALL PROVIDE 341500KGM11 (MV -I05), 167506, 5 "G. ALL EXPOSED CONDUIT SHALL BE RIGID GALVANIZED STEEL (RG5). O KIRK KEY INTERLOCK. EG SHALL PROVIDE CONTROL WIRING BETWEEN KIRK KEY AND GEAR. KIRK KEY SHALL BE TYPE F, ZERO BOLT PROJECTION. KIRK KEY SHALL ALSO BE PROVIDED WITH AN AUXILIARY SWITCH TO CLOSE WHEN THE BOLT 15 RETRACTED (NORMAL BREAKER OPERATION). PDU MESH MECH 1 MESH 1 MESH 1 O O FUTURE FUTURE CHILLER CHILLER MESH MECH MESH MESH EXISTING ONE -LINE DIAGRAM ELECTRICAL ONE -LINE DIAGRAM E3.0 SCALE: NONE MESH e MGG -I, 600A 480/277V PANEL 'HA' TXG -I 75kVA TRANSFORMER 480V PRIMARY 206 /120 SECONDARY PANEL 'LA' d 2 3l_ Q • 8 N • PANEL TXG -2 75kVA TRANSFORMER 480V PRIMARY 208 /120 SECONDARY PANEL 'LB' REVIEWED .i. OF COMPLIANCE WITH NFPA70 - NEC FEB 16 2011 - City of Tukwila BUILDING DIVISION FAULT CURRENT CALCULATION SCHEDULE POINT LOCATION DESCRIPTION LENGTH (1 (ft) VOLTAGE (EL-L) VOLTAGE (E1 -W PHASE WIRE SIZE CONDUCTOR MATERIAL CONDUCTOR TYPE CONDUIT MATERIAL VOLTAGE CLASS G VALUE * OF PARALLEL RUNS Is AVAILABLE UPSTREAM f L -L M L-L Is AT EQUIP (13p OIR (IL -L) POINT FO MV SE CONDARY - -- - - - - 6 0,1 4 642 FO Fl PANEL SHA 25 4E0 211 3 500 COPPER THREE SINGLE CONDUCTORS STEEL 600'V 22185 8 60,142 0.03 0.411 58358 Fl NOTES, L ALL CALCULATIONS WERE DONE USING BUSSMAN 'POINT -TO- POINT' METHOD. 2. REFER TO PLANS FOR ASSUMED UTILITY TRANSFORMER SIZE UTILIZED FOR CALCULATIONS. CCI r/ r U.,1‘..-0 0 8 FEB Oa 2011 PERMIT CENTER O Cl Ci O W F- HV z Z 1 1 1 < Q W- u Z Q N /W V1 O� M DESCRIPTION w tri Z s. J a ,n w m w CHECKED BY: 02/02/2011 ISSUE DATE: 0 111 U w z0 00 Copyright © 2009 - A I right reserved Architectural Engineer) g De Ign Group, Inc. All design drawings and written material herein may not be used or duplicated without the written consent of Architectural Engineering Design Group, Inc. SHEET NO.: E3.0