Loading...
HomeMy WebLinkAboutPermit EL11-0092 - SABEY DATA CENTER - SDC42SABEY DATA CENTER 3355 S 120 PL EL1 1 -0092 Parcel No.: Address: Tenant Name: Cityif Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite # 100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 inspection Request Line: 206 - 431 -2451 Web site: http: / /www.ci.tukwila.wa.us 1023049082 3355 S 120 PL TUKW SABEY DATA CENTER - SDC42 ELECTRICAL PERMIT Permit Number: Issue Date: Permit Expires On: EL1 1-0092 02/28/2011 08/27/2011 Owner: Name: SABEY CORPORATION Address: 12201 TUKVVILA INTL BLVD , 4TH FLOOR 98168 Contact Person: Name: LAURA RANNOW Address: 5614 7 AV S , SEATTLE WA 98108 Contractor: Name: VECA ELECTRIC CO INC Address: 5617 7TH AVE S , SEATTLE WA 98108 Contractor License No: VECAECI542MU Phone: 206 - 436 -5245 Phone: 206 860 -0231 Expiration Date: 10/31/2011 DESCRIPTION OF WORK: PROVIDE ELECTRICAL INFRASTRUCTURE FOR BUS A, B & C Value of Electrical Work: NRES: 4,500,000.00 RES: $0.00 Type of Fire Protection: UNKNOWN Electrical Service Provided by: SEATTLE CITY LIGHT Permit Center Authorized Signature: Fees Collected: $34,583.94 National Electrical Code Edition: 2008 Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the perfo i mice of work. I am thorized to sign and obtain this electrical permit and agree to the conditions on the back of this permit. L. Signature: / clo Date: 2_12.1J1 ( Print Name: Haeit.k This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -9/09 EL1 1-0092 Printed: 02 -28 -2011 0 • PERMIT CONDITIONS Permit No. EL11 -0092 * *ELECTRICAL ** 1: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 2: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 3: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 4: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 5: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 6: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. doc: EL -9/09 EL11 -0092 Printed: 02 -28 -2011 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Electrical Permit No. Project No. (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: 3355 South 120th Place Tenant Name: Sabey Data Center Property Owners Name: Sabey Corporation LLC Mailing Address: 12201 Tukwila Intl Blvd , 4th Fl King Co Assessor's Tax No.: I 0•1 30 Z-i— 90 9 �- Suite Number: 42 New Tenant: Floor: ❑ Yes © ..No Tukwila City WA State 98168 Zip CONTACT PERSON - Who do we contact when your permit is ready to be issued Name: Laura Rannow Mailing Address: 5614 7th Ave S E-Mail Address: Iaura.rannow @veca.com Seattle Day Telephone: ?06- 436 -5245 City Fax Number: WA State 206 - 763 -0505 98108 Zip ELECTRICAL CONTRACTOR INFORMATION Company Name: VECA Electric Co, INC Mailing Address: 5614 7th Ave S Contact Person: Terry McCabe E -Mail Address: terry mccabe @veca com Contractor Registration Number: VECAECI542MU Seattle WA City State Day Telephone: 206 - 436 -5221 Fax Number: 206 - 763 -0505 Expiration Date: 10/31/11 98108 Zip Valuation of Project (contractor's bid price): $ 4,500,000 Scope of Work (please provide detailed information): Provide electrical infrastructure for Bus A, B & C Will service be altered? IN Yes ❑ No Adding more than 50 amps? ® Yes ❑ No Type of Use: Type of work: ❑ New ® Addition ❑ Service Change ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service ❑ Remodel ❑ Tenant Improvement Property Served by: ❑ Puget Sound Energy ® Seattle City Light 1i: \Applications\Porm s- Applications On Line \4 -2007 - Electrical Permit Application.doc bh Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $140.00 (including an attached garage) ❑ Garages, pools, spas and outbuildings $75.00 ea ❑ Low voltage systems (alarm, furnace thermostat) $55.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $75.00 (no added/altered circuits) ❑ Service change with added/altered circuits $75.00 number of added circuits $10.00 ea ❑ Circuits added/altered without service change $50.00 (up to 5 circuits) ❑ Circuits added/altered without service change $50.00 (6 or more circuits) $7.00 ea ❑ Meter /mast repair $65.00 ❑ Low voltage systems $55.00 (alarm, furnace thermostat) MULTI - FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $58.00 ❑ Temporary service (generator) $75.00 ❑ Manufactured/mobile home service $80.00 (excluding garage or outbuilding) ❑ Carnivals $75.00 Number of concessions $10.00 ea Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERT Y THAT I HAVE REA AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PE i.' Y BY THE LAWS S HE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWN OR ELECTRICAL 9 NTRACTOR: Signature: Date: 2/03/11 Print Name: Terry McCabe Mailing Address: 5614 7th Ave S Seattle. WA 98108 Date Application Accepted: Day Telephone: 206- 436 -5221 City State Zip Date Application Expires: Staff Initials: H1Applications \Forms - Applications On Lineal -2007 - Electrical Permit Application.doc bh Page 2 of 2 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: htqx//www.ci.tukwila.wa.us Parcel No.: 1023049082 Address: 3355 S 120 PL TUKW Suite No: Applicant: SABEY DATA CENTER - SDC42 RECEIPT Permit Number: EL11 -0092 Status: APPROVED Applied Date: 02/04/2011 Issue Date: Receipt No.: R11 -00356 Payment Amount: $27,667.15 Initials: WER Payment Date: 02/28/2011 09:23 AM User ID: 1655 Balance: $0.00 Payee: TERRY MCCABE TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 02521C ACCOUNT ITEM LIST: Description 27,667.15 Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.00 27,667.15 Total: $27,667.15 doc: Receiot -06 Printed: 02 -28 -2011 III 1 -- w� City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www. ci. tukwi la. wa. us Parcel No.: 1023049082 Address: 3355 S 120 PL TUKW Suite No: Applicant: SABEY DATA CENTER RECEIPT Permit Number: EL11 -0092 Status: PENDING Applied Date: 02/04/2011 Issue Date: Receipt No.: R11 -00216 Initials: User ID: WER 1655 Payment Amount: $6,916.79 Payment Date: 02/04/2011 11:33 AM Balance: $27,667.15 Payee: TERRY MCCABE TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 314028 ACCOUNT ITEM LIST: Description 6,916.79 Account Code Current Pmts ELECTRICAL PLAN - NONRES 000.345.832.00.00 6,916.79 Total: $6,916.79 doc: Receiot -06 Printed: 02 -04 -2011 INSPECTION NO. INSPECTION RECORD Retain a copy with-permit &�I -DoiL PERMIT NO. CITY OF TUKWILA BUILDING DIVISION lJ 6300 Southcenter Blvd., #100, Tukwila. WA 98188 g- (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project:`) 51)01 Type of Inspection: Address: 33�5 S - X20 Pi,. Date Called: Special Instructions: Date Wanted:. v7 a:m: Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: • Date: 02107 1 Zr REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION,RECORD Retain a copy with permit ERMIT NO. CITY OF' TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -36 Permit Inspection Request Line (206) 431 -2451 Project: • S D Ia., Type of Inspection: 2/00 Address: - /2.0 PL Date Called: �. Special Instructions: Date Wanted:. 1 / 03 I / 4.im......n.Reuester: Phone No: Approved per applicable codes. a Corrections required prior to approval. COMMENTS: Pfri rn4K/ Pft,JC-t n/►D P.soc_ -R ct n.8 pl 'f a,JD r ksSdc.t -i f bi(r - ((l k i Q61 QC "iii Inspector: fl Date: 11 u3 tl REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be • paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. 10 INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 cr. (206) 431-36 Permit Inspection Request Line (206) 431 -2451 Project: S �. ' SbC_ii 2, Type of Inspection: AO3 Address: 33 120ii Date Called: • Special Instructions: Date Wanted:. ilm. ( 7 p'5. Requester: Phone No: Approved per applicable codes. 0 Corrections required prior to approval. COMMENTS: oe GEruAlh c.NJt-ii) !.b/it, 2 Roa asT) - K044 i^I 69`lf Inspector: s6 Date: 0 ll 111 ❑ REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit tu( 007Z- P MIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: SAC, r Type of Inspection: 7o,3 Addess: 3355- s- 126PL- Date Called: Special Instructions: Date Wanted:. 01 a m Requester: Phone No: ElApproved per applicable codes. ElCorrections required prior to approval. COMMENTS: -g- caNiegl L6/6-L Z Xi. 1 6%-sT) Inspector: Date: D7 1Z I I REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. : . INSPECTION NO. • INSPECTION RECORD Retain a-copy-.with permit ERMITNI. / N CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 W." (206) 431-367 Permit Inspection Request Line (206) 431-2451 Project: 56 $p - csiz. Type of Inspection: 60 RID Address: 33, , 5 ,,, - Date Called: .., _ Special Instructions: Date Wanted: 7/21? 4!eilii. Requester: I Phone No: EAppmved per applicable codes. Corrections required prior to approval. • • • COMMENTS: . . ., , . ..- FA ' VA14, /4410., f 64 goi .., 0407.k-A02---- oy-0045 kmatia) ii. 040 641)4#43 esAiNieroiti 1PJkTi5T Inspector: Date: • •-• • • • REINSPECTION FEE REQUIRED. Prior to next inspection. fee tp.4412,0); paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule rein. • • . INSPECTION 'RECORD Retain a copy with" permit ' INSPECTION NO. ERMIT Nb. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 pg. (206) 431 -367 Permit Inspection Request Line (206) 431 -2451 Project: Ais(7 - SJC.' ^ L Typ e of Inspection: 7oo2- Address: ass5./ 26PL. Date Called: Special Instructions: Date Wanted: v%Lf-411d1 I, tiAle 1 4.o c.k11. Requester: Phone No: 0 Approved per applicable codes. Corrections required prior to approval. COMMENTS: / 4i.ej - t1;611' GAD . its 1 TO - K dG c5U L1t� 5e/Sri! r1 B2 roc /# &3 , Jge 5 13 - ealotors cb4Doc Tags„ TE <4i%AJ -^7045, , 4 naPiOtAi iodDif1Ga r v%Lf-411d1 I, tiAle 1 4.o ,S °;(MI5 0 4- 4$ i2 - 42-64P 1161-1 A ilm, in c, -Hi `ic -i.. N2 & -IA Inspector: Date: %/ 1 DlZZ /l l ri REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 l ' (206) 431 -367 Permit Inspection Request Line (206) 431 -2451 Project: — ���� Type of Inspection: 0 2, 7 ,, Address: rs.,zdA. Date Called: - n OC. Special Instructions: Date Wanted: 7/7 a.m p.m. Requester: Phone No: EJApproved per applicable codes. ElCorrections required prior to approval. COMMENTS: Cav ,, — (A )e rof $, &4tJi 13, 'firs tt4ouNg Viry&O 4 ails - n OC. vPP MAL lD—j G,L2.- 0811 Date: 07 %1 f r7 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Inspector: INSPECTION RECORD Retain a copy with permit INSPECTION NO. ERMIT N OF TUKWILA BUILDING DIVISION 6 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -36 Permit Inspection Request Line (206) 431 -2451 Project: — Sbc. Y2- Type of Inspection: 7 , . Address Date Called: • Special Instructions: Date Wanted: 7� S C/ a.m Requester: I Phone No: . 0 Approved per applicable codes. Corrections required prior to approval. COMMENTS: A- - foci-ro? Ca, ectribJti . ectAINt o f � 1 4• SAP ArI9 t /F� • Inspector: Date: n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection•' • : - - ' - •., • INSPECTION, RECORD Retain a copy with permit INSPECTION NO. ERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -367 Permit Inspection Request Line (206) 431 -2451 Project: J bC- 12- Type of Inspection: 0 D `� Address: ass 5.121 .∎ • Date Called: Special Instructions: (74- ��,,��,,!! Date Wanted: /' o / Qrs. Requester: ff Phone No: JApproved per applicable codes. El Corrections required prior to approval. ?A- COMMENTS: L@it., dam eon w ti �e(sr'I Date: 06/10/1 I I REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Inspector: F. INSPECTION RECORD �1 Retain a copy with permit C Dd . INSPECTION NO. P RMIT N CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -36 Permit Inspection Request Line (206) 431 -2451 Project: 5D C Z Type of Inspection: O 0 a3 Address: Date Called: Special Instructions: Date Wanted: J 2�Requester: a:m: Phone No: ElApproved per applicable codes. ElCorrections required prior to approval. COMMENTS: (,J A-rsH) 4,erk9Lij> Inspector: Date: ❑ REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection: r. 2- INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT N0'. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 t:- (206) 431 -367 Permit Inspection Request Line (206) 431 -2451 - 641-002. Project: _ jbC LiZ Type of Inspection: ,700/3 Address:33 SS. /n _ pr, Date Called: Special Instructions: Date Wanted: /5" p.m. Requester: Phone No: ElApproved per applicable codes. a Corrections required prior to approval. COMMENTS: 1p LAM-14. Goo' lZ U-Pra t FLQo \ aoaftApoirk Date: 0 I � i ! F-7 REINSPECTIO FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Inspector: / - ..,,... Vag ,�b,.�.. �. 1.•• • INSPECTION RECORD' Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION ea- 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -36 Permit Inspection Request Line (206) 431 -2451 ‘14,-ote, Project: e , ,it de l i yv Type of Inspection: /J05, f/ Address: 335- S� Q Date Called: Special Instructions: Date Wanted: r ® a:m m. Requester: Phone No: ❑ Approved per applicable codes. Corrections required prior to approval. COMMENTS: , q+A wav a5C94E9u[.F Inspector: Date: 03/;y/ii I I REINSPECTION tEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. .` 1 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION r" Luf -Oo7). 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 431 -2451 (206) 431 -367 Project: ( „ � (5� ���2�1( =/(' Type of Inspection: 7oof Address: // 7,//�� /.5/5- _5• / V� • Date Called: r Special Instructions: • Date Wanted: 31 P• (�` Requester: Phone No: ❑ Approved per applicable codes. a Corrections required prior to approval. COMMENTS: uhipces146 11661 � CD4c>on, 11) Inspector: Date: og • Lt1O 92 FEB 04 2011 PERMIT CENTER VECA Electric SWBD HDP -42A TM 603376 ROOM: SDC 42 MAIN ELEC ROOM LOAD DISTRIBUTION FROM: UNIT SUBSTATION HVS 42A RCPT LTG EQP HEAT BRKR DESCRIPTION AMP P kVA AMPS 0.0 0.0 710.0 1 UPS -42 -A1 PRIMARY 1200 3 710 854 2 - - AMP: 4000 3 MBP -42 -A1 MAINT BYPASS 1200 3 - - VOLTS: 0 0.0 0.0 710.0 0.0 4 UPS -42 -A2 PRIMARY 1200 3 710 854 480 5 - - PHASE: 3 6 MBP -42 -A2 MAlI!NT BYPASS 1200 3 - - WIRE: 3 7 ©b 8 r■ ■ - - A`I.C.: 65K 9 - - M.L.O.: NO 10 UPS 42`T3PRi* 350 3 - - MAIN CB: YES 11 UPS -42 -A3 STATIC BYPASS 350 3 - - FUSE: NO 12 MBP -42 -A3 MAINT BYPASS 350 3 - - FLUSH: NO 13 M-42A 2500 3 - - SURF: YES 0.0 0.0 0.0 0.0 14 PNL- 42A -H1 VIA XFMR- 42A -H1 70 3 - - 1.0 0.0 0.0 0.0 15 PNL- 42A -L1 VIA XFMR- 42A -L1 50 3 1 1 16 TVSS 100 3 - - IG GND: NO 17 - - 200% N: NO 18 - - FD THRU: NO 19 - - DBL LUG: NO 39.0 20 RF -42A1 -2nd Floor Mechanical Room 80 3 39 47 TOP: YES 39.0 21 RF -42A2 -2nd Floor Mechanical Room 80 3 39 47 BTM: NO 39.0 22 RF -42A3 -2nd Floor Mechanical Room 80 3 39 47 80.0 23 AHU -42A1 -2nd Floor Mechanical Room 150 3 80 96 PANEL T.C.L. 80.0 24 AHU -42A2 -2nd Floor Mechanical Room 150 3 80 96 LOAD (kVA) 25 SPARE 1200 3 - - RCPT 1 26 SPARE 800 3 - - LTG - 27 SPARE 150 3 - - EQP 1,717 28 SPARE 100 3 - - HEAT - 29 SPARE 60 3 - - 30 - - TOTAL 1,718 31 - - 20.0 32 25% OF LARGEST MOTOR 20 24 FEEDER T.C.L. 33 --- - - LOAD (kVA) 34 D FOR - - RCPT 1 35 MPLIANCE tltlI 1 H COMPLIANCE CO - - LTG - 36 7®- NEC - - EQP 1,717 37 NEP/� �`A - - HEAT - 38 - - 39 FEB 1 rl 2011 7 - - TOTAL 1,718 40 - - 41 _ - - FEEDER DEMAND 42 ...... City of Yukwfla - - kVA 1,718 BUILDING DIVISION TOTAL 1,718 2,066 AMPS 2,066 1 - 1,7171 - MFG: CB: Feeders NOTE: Provide IR Scan Windows and Compression Lugs for Incoming Feeder T.C.L. is printed here horizontally I to allow a block "paste -link" to the "Load Distribution" columns of a sub - feed panel or switchboard. ?' ,.' I I 1 Project: SDC 42 Phase I '•, 02/04/11 Lt1O 92 FEB 04 2011 PERMIT CENTER 1 VECA Electric SWBD MBP -42 -A1 ROOM: SDC 42 MAIN ELEC ROOM TM 603376 LOAD DISTRIBUTION FROM: UPS -42 -A1 / HDP -42A RCPT LTG EQP HEAT BRKR DESCRIPTION AMP P kVA AMPS 142.0 1 PDC- 42 -A1.1 350 3 142 171 142.0 2 PDC- 42 -A1.2 350 3 142 171 AMP: 1200 142.0 3 PDC- 42 -A1.3 350 3 142 171 VOLTS: 142.0 4 PDC- 42 -A1.4 350 3 142 171 480 142.0 5 PDC- 42 -A1.5 350 3 142 171 PHASE: 3 6 SPARE 350 3 - - WIRE: 3 - - BUS: CU - - A.I.C.: 85K - - M.L.O.: - - MAIN CB: NO - - FUSE: NO - - FLUSH: NO - - SURF: YES - - IG GND: NO - - 200% N: NO - - FD THRU: YES - - DBL LUG: YES - - TOP: YES - - BTM: NO - PANEL T.C.L. - - LOAD (kVA) - - RCPT - - - LTG - - - EQP 710 - - HEAT - - - TOTAL 710 - - FEEDER T.C.L. - - LOAD (kVA) - - RCPT - - - LTG - - - EQP 710 - - HEAT - - - TOTAL 710 - - FEEDER DEMAND - - kVA 710 TOTAL 710 854 AMPS 854 - - 710 - MFG: CB: NOTE: Provide Compression Lugs for Incoming Feeders Feede T.C.L. is printed here horizontally to allow a block "paste -link' to the "Load Distribution" columns of a sub - feed panel or switchboard. I I I Project: SDC 42 Phase I 02/04/11 r VECA Electric SWBD MBP -42 -A2 ROOM: SDC 42 MAIN ELEC ROOM TM 603376 LOAD DISTRIBUTION FROM: UPS -42 -A2 / HDP -42A RCPT LTG EQP HEAT BRKR DESCRIPTION AMP P kVA AMPS 142.0 1 PDC- 42 -A2.1 350 3 142 171 142.0 2 PDC- 42 -A2.2 350 3 142 171 AMP: 1200 142.0 3 PDC- 42 -A2.3 350 3 142 171 VOLTS: 142.0 4 PDC- 42 -A2.4 350 3 142 171 480 142.0 5 PDC- 42 -A2.5 350 3 142 171 PHASE: 3 6 SPARE 350 3 - - WIRE: 3 - - BUS: CU - - A.I.C.: 85K - - M.L.O.: - - MAIN CB: NO - - FUSE: NO - - FLUSH: NO - - SURF: YES - - IG GND: NO - - 200% N: NO - - FD THRU: YES - - DBL LUG: YES - - TOP: YES - - BTM: NO - - PANEL T.C.L. - LOAD (kVA) - - RCPT - - - LTG - - - EQP 710 - - HEAT - , - - TOTAL 710 - - FEEDER T.C.L. - - LOAD (kVA) - - RCPT - - - LTG - - - EQP 710 - - HEAT - - - TOTAL 710 - - FEEDER DEMAND - - kVA 710 TOTAL 710 854 AMPS 854 - - 710 - MFG: CB: NOTE: Provide Compression Lugs for Incoming Feeders Feede T.C.L. is printed here horizontally to allow a block 'paste -link' to the "Load Distribution" columns of a sub - feed panel or switchboard. I I 1 Project: SDC -42 Phase I 02/04/11 VECA Electric PANEL: PNL- 42A -H1 ROOM: SDC 42 UPS ROOM FEED -THRU: TM 603376 LOADS FROM: HDP -42A VIA XFMR- 42A -H1 A B C RCPT LTG EQP HEAT CKT DESCRIPTION PH AMP P KVA AMPS KVA AMPS KVA AMPS 1 A 20 1 0.0 0.0 3 B 20 1 0.0 0.0 AMP: 100 5 C 20 1 0.0 0.0 VOLTS: 277 7 A 20 1 0.0 0.0 480 9 B 20 1 0.0 0.0 PH: 3 11 C 20 1 0.0 0.0 WIRE: 4 13 A 20 1 0.0 0.0 BUS: CU 15 B 20 1 0.0 0.0 A.I.C.: 65K 17 C 20 1 0.0 0.0 MLO: YES 19 A 20 1 0.0 0.0 MCB: YES 21 B 20 1 0.0 0.0 3R: NO 23 C 20 1 0.0 0.0 FLUSH: NO 25 A 20 1 0.0 0.0 SURF: YES 27 B 20 1 0.0 0.0 29 C 20 1 0.0 0.0 A 20 1 0.0 0.0 IG GRND NO B 20 1 0.0 0.0 200% N: NO C 20 1 0.0 0.0 FD THRU NO A 20 1 0.0 0.0 DBL LUG NO B 20 1 0.0 0.0 TOP: YES C 20 1 0.0 0.0 BTM: YES 2 A 20 1 0.0 0.0 PANEL T.C.L. 4 B 20 1 0.0 0.0 LOAD (kVA) 6 C 20 1 0.0 0.0 RCPT 0.0 8 A 20 1 0.0 0.0 LTG 0.0 10 B 20 1 0.0 0.0 EQP 0.0 12 C 20 1 0.0 0.0 HEAT 0.0 14 A 20 3 0.0 0.0 i 16 B 0.0 0.0 TOTAL 1 0.0 18 C 0.0 0.0 c 20 A 30 3 0.0 0.0 FEEDER T.C.L. u 22 B 0.0 0.0 LOAD (kVA) 24 C " " 0.0 0.0 RCPT 0.0 26 A 50 3 0.0 0.0 LTG 0.0 28 B 0.0 0.0 EQP 0.0 30 C 0.0 0.0 HEAT 0.0 0.0 0.0 0.0 0.0 TOTAL 0.0 0.0 0.0 LG MTR 0.0 0.0 FEEDER DEMAND 0.0 0.0 kVA 0.0 0.0 0.0 AMPS 0.0 - A 0.0 0.0 - B 0.0 0.0 - C 0.0 0.0 0.0 0.0 0.0 0.0 KVA/AMPS: 0.0 0.0 0.0 0.0 0.0 0.0 Mfg/Type: 0.0 0.0 0.0 0.0 A CB Type: 0.0 0.0 0.0 0.0 B Remarks: - Provide Auxillary Ground Bar and Door in Door Construction 0.0 0.0 0.0 0.0 C VECA Electric PANEL: PNL- 42A -L1 ROOM: SDC 42 UPS ROOM FEED -THRU: TM 603376 LOADS FROM: HSP -42A VIA XFMR- 42A -L1 A B C RCPT LTG EQP HEAT CKT DESCRIPTION PH AMP P KVA AMPS KVA AMPS KVA AMPS 0.2 1 RECEPTACLE IN SDC 42 UPS ROOM A 20 1 0.2 1.5 0.2 3 RECEPTACLE IN GENERATOR ROOM B 20 1 0.2 1.7 AMP: 100 0.2 5 ALC CONTROLLER IN UPS ROOM C 20 1 0.2 1.7 VOLTS: 120 0.2 7 RECEPTACLE IN SDC 42 MECH. SPACE A 20 1 0.2 1.7 208 0.2 9 RECEPTACLE IN SDC 42 MECH. SPACE B 20 1 0.2 1.7 PH: 3 11 C 20 1 0.0 0.0 WIRE: 4 13 A 20 1 0.0 0.0 BUS: AL 15 B 20 1 0.0 0.0 A.I.C.: 65K 17 C 20 1 0.0 0.0 MLO: YES 19 A 20 1 0.0 0.0 MCB: 21 B 20 1 0.0 0.0 3R: 23 C 20 1 0.0 0.0 FLUSH: 25 A 20 1 0.0 0.0 SURF: YES 27 B 20 1 0.0 0.0 29 C 20 1 0.0 0.0 31 A 20 1 0.0 0.0 IG GRND. 33 B 20 1 0.0 0.0 200% N: 35 C 20 2 0.0 0.0 FD THRU NO 37 A 20 2 0.0 0.0 DBL LUG 39 8 20 2 0.0 0.0 TOP: YES 41 C 20 2 0.0 0.0 BTM: 2 A 20 1 0.0 0.0 PANEL T.C.L. 4 B 20 1 0.0 0.0 LOAD (kVA) 6 C 20 1 0.0 0.0 RCPT 1.0 8 A 20 1 0.0 0.0 LTG 0.0 10 B 20 1 0.0 0.0 EQP 0.0 12 C 20 1 0.0 0.0 HEAT 0.0 14 A 20 1 0.0 0.0 i 16 B 20 1 0.0 0.0 TOTAL 1.0 18 C 20 1 0.0 0.0 c 20 A 20 1 0.0 0.0 FEEDER T.C.L. f• 22 B 20 1 0.0 0.0 LOAD (kVA) 24 C 20 1 0.0 0.0 RCPT 1.0 26 A 20 1 0.0 0.0 LTG 0.0 28 B 20 1 0.0 0.0 EQP 0.0 30 C 20 1 0.0 0.0 HEAT 0.0 32 A 20 1 0.0 0.0 34 B 20 1 0.0 0.0 TOTAL 1.0 36 C 20 1 0.0 0.0 LG MTR 38 A 20 1 0.0 0.0 FEEDER DEMAND 40 B 20 1 0.0 0.0 kVA 1.0 42 C 20 1 0.0 0.0 AMPS 2.7 - A 0.0 0.0 - B 0.0 0.0 - C 0.0 0.0 1.0 0.0 0.0 0.0 KVA/AMPS: 0.4 3.2 0.4 3.3 0.2 1.7 Mfg/Type: 0.4 0.0 0.0 0.0 A CB Type: 0.4 0.0 0.0 0.0 B Remarks: - Provide Auxiliary Ground Bar and Door in Door Construction 0.2 0.0 0.0 0.0 C 1 VECA Electric SweD HDP -42B ROOM: SDC 42 MAIN ELEC ROOM TM 603376 LOAD DISTRIBUTION FROM: UNIT SUBSTATION HVS -42B RCPT LTG EQP HEAT BRKR DESCRIPTION AMP P kVA AMPS 0.0 0.0 475.0 0.0 1 UPS 42 -B1 PRIMARY 1200 3 475 571 2 - - AMP: 4000 3 MBP -42 -B1 MAINT BYPASS 1200 3 - - VOLTS: 0.0 0.0 475.0 0.0 4 UPS 42 -B2 PRIMARY 1200 3 475 571 480 5 - - PHASE: 3 6 MBP -42 -B2 MAINT BYPASS 1200 3 - - WIRE: 3 7 - - BUS: CU 8 - - A.I.C.: 85K 9 - - M.L.O.: NO 10 UPS 42 -B3 PRIMARY 350 3 - - MAIN CB: YES 11 UPS 42 -B3 STATIC BYPASS 350 3 - - FUSE: NO 12 MBP -42 -B3 MAINT BYPASS 350 3 - - FLUSH: NO 13 M-42B 2500 3 - - SURF: YES 0.0 11.1 0.0 0.0 14 PNL- 42B -F11 VIAXFMR- 42B -H1 70 3 11 13 5.5 1.6 7.8 0.0 15 PNL- 42B -L1 VIA XFMR- 42B -L1 50 3 15 18 16 TVSS 100 3 - - IG GND: NO 17 - - 200% N: NO 18 - - FD THRU: NO 19 - - DBL LUG: NO 39.0 20 RF -42B1 -2nd Floor Mechanical Room 80 3 39 47 TOP: YES 39.0 21 RF -42B2 -2nd Floor Mechanical Room 80 3 39 47 BTM: NO 39.0 22 RF -42B3 -2nd Floor Mechanical Room 80 3 39 47 80.0 23 AHU -42B1 -2nd Floor Mechanical Room 150 3 80 96 PANEL T.C.L. 80.0 24 AHU -42B2 -2nd Floor Mechanical Room 150 3 80 96 LOAD (kVA) 25 SPARE 1200 3 - - RCPT 5 26 SPARE 800 3 - - LTG 13 27 SPARE 150 3 - - EQP 2,286 28 SPARE 100 3 - - HEAT - 29 SPARE 60 3 - - 30 - - • TOTAL 2,304 31 - - 20.0 32 25% OF LARGEST MOTOR 20 24 FEEDER T.C.L. 33 - - LOAD (kVA) 485.0 34 CH -42B1 -Roof Chiller 800 3 485 583 RCPT 5 485.0 35 CH -4282 -Roof Chiller 800 3 485 583 LTG 13 22.0 36 CHP -42B1 -Roof Pump 60 3 22 26 EQP 2,286 22.0 37 CHP -42B2 -Roof Pump 60 3 22 26 HEAT - 12.5 38 CRAC -42B1 -1st Floor UPS Room 20 3 13 15 5.0 39 EF -42B1 -1st Floor Generator Room 20 3 5 6 TOTAL 2,304 40 - - 41 - - FEEDER DEMAND 42 - - kVA 2,308 TOTAL 2,304 2,772 AMPS 2,776 5 13 2,286 - MFG: CB: NOTE: Provide IR Scan Windows and Compression Lugs for Incoming Feeders Feede T.C.L. is printed here horizontally to allow a block "paste -link' to the "Load Distribution" columns of a sub - feed panel or switchboard. I I 1 Project: SDC -42 Phase! 02/04/11 VECA Electric SWBD MBP -42 -B1 ROOM: SDC 42 MAIN ELEC ROOM TM 603376 LOAD DISTRIBUTION FROM: UPS -42 -B1 / HDP -42B RCPT LTG EQP HEAT BRKR DESCRIPTION AMP P kVA AMPS 237.5 1 STS- 42 -BC1 PRIMARY 800 3 238 286 2 STS- 42 -CB1 SECONDARY 800 3 - - AMP: 1200 237.5 3 STS- 42 -BD1 PRIMARY 800 3 238 286 VOLTS: 4 STS- 42 -DB1 SECONDARY 800 3 - - 480 5 SPARE 800 3 - - PHASE: 3 6 SPARE 800 3 - - WIRE: 3 7 SPARE 800 3 - - BUS: CU 8 SPARE 800 3 - - A.I.C.: 65K - - M.L.O.: - - MAIN CB: NO - - FUSE: NO - - FLUSH: NO - - SURF: YES - - IG GND: NO - - 200% N: NO - - FD THRU: YES - - DBLLUG: YES - - TOP: YES - - BTM: NO - - PANEL T.C.L. - - LOAD (kVA) - - RCPT - - - LTG - - - EQP 475 - - HEAT - - - TOTAL 475 - - FEEDER T.C.L. - - LOAD (kVA) - - RCPT - - - LTG - - - EQP 475 - - HEAT - - - TOTAL 475 - - FEEDER DEMAND - - kVA 475 TOTAL 475 571 AMPS 571 - - 475 - MFG: CB: NOTE: Provide Compression Lugs for Incoming Feeders Feede T.C.L. is printed here horizontally to allow a block paste -link" to the "Load Distribution" columns of a sub - feed panel or switchboard. I I I Project: SDC -42 Phase I 02/04/11 VECA Electric SWBD MBP -42 -B2 ROOM: SDC 42 MAIN ELEC ROOM TM 603376 LOAD DISTRIBUTION FROM: UPS -42 -B2 / HDP -42B RCPT LTG EQP HEAT BRKR DESCRIPTION AMP P kVA AMPS 237.5 1 STS- 42 -BC2 PRIMARY 800 3 238 286 2 STS- 42 -CB2 SECONDARY 800 3 - - AMP: 1200 237.5 3 STS- 42 -BD2 PRIMARY 800 3 238 286 VOLTS: 4 STS- 42 -DB2 SECONDARY 800 3 - - 480 5 SPARE 800 3 - - PHASE: 3 6 SPARE 800 3 - - WIRE: 3 7 SPARE 800 3 - - BUS: CU 8 SPARE 800 3 - - A.I.C.: 85K - - M.L.O.: - - MAIN CB: NO - - FUSE: NO - - FLUSH: NO - - SURF: YES - - IG GND: NO - - 200% N: NO - - FD THRU: YES - - DBL LUG: YES - - TOP: YES - - BTM: N/A - - PANEL T.C.L. - - LOAD (kVA) - - RCPT - - - LTG - - - EQP 475 - - HEAT - - - TOTAL 475 - - FEEDER T.C.L. - - LOAD (kVA) - - RCPT - - - LTG - - - EQP 475 - - HEAT - - - TOTAL 475 - - FEEDER DEMAND - - kVA 475 TOTAL 475 571 AMPS 571 - - 475 - MFG: CB: NOTE: Provide Compression Lugs for Incoming Feeders Feede T.C.L. is printed here horizontally to allow a block "paste -link" to the "Load Distribution" columns of a sub - feed panel or switchboard. I I I Project: SDC -42 Phase I 02/04/11 VECA Electric PANEL: PNL -42B -H1 ROOM: SDC 42 UPS ROOM FEED -THRU: TM 603376 LOADS FROM: HDP -42B A B C RCPT LTG EQP HEAT CKT DESCRIPTION PH AMP P KVA AMPS KVA AMPS KVA AMPS 1.7 1 UPS ROOM LIGHTING A 20 1 1.7 6.1 1.7 3 GENERATOR ROOM LIGHTING B 20 1 1.7 6.1 AMP: 100 1.7 5 MECHANICAL RM LIGHTING C 20 1 1.7 6.1 VOLTS: 277 2.0 7 SUITE 42 -01 LIGHTING A 20 1 2.0 7.2 480 2.0 9 SUITE 42 -02 LIGHTING B 20 1 2.0 7.2 PH: 3 2.0 11 SUITE 42 -03 LIGHTING C 20 1 2.0 7.2 WIRE: 4 13 A 20 1 0.0 0.0 BUS: CU 15 B 20 1 0.0 0.0 A.I.C.: 65K 17 C 20 1 0.0 0.0 MLO: NO 19 A 20 1 0.0 0.0 MCB: YES 21 B 20 1 0.0 0.0 3R: NO 23 C 20 1 0.0 0.0 FLUSH: NO 25 A 20 1 0.0 0.0 SURF: YES 27 B 20 1 0.0 0.0 29 C 20 1 0.0 0.0 0.0 0.0 IG GRND NO 0.0 0.0 200% N: NO 0.0 0.0 FD THRU NO 0.0 0.0 DBL LUG NO 0.0 0.0 TOP: YES 0.0 0.0 BTM: YES 2 A 20 1 0.0 0.0 PANEL T.C.L. 4 B 20 1 0.0 0.0 LOAD (kVA) 6 C 20 1 0.0 0.0 RCPT 0.0 8 A 20 1 0.0 0.0 LTG 11.1 10 B 20 1 0.0 0.0 EQP 0.0 12 C 20 1 0.0 0.0 HEAT 0.0 14 A 20 3 0.0 0.0 i 16 B 0.0 0.0 TOTAL 11.1 18 C " 0.0 0.0 c 20 A 30 3 0.0 0.0 FEEDER T.C.L. fi 22 B 0.0 0.0 LOAD (kVA) 24 C 0.0 0.0 RCPT 0.0 26 A 50 3 0.0 0.0 LTG 11.1 28 B 0.0 0.0 EQP 0.0 30 C " " 0.0 0.0 HEAT 0.0 0.0 0.0 0.0 0.0 TOTAL 11.1 0.0 0.0 LG MTR 0.0 0.0 FEEDER DEMAND 0.0 0.0 kVA 13.9 0.0 0.0 AMPS 16.7 - A 0.0 0.0 - B 0.0 0.0 C " " 0.0 0.0 0.0 11.1 0.0 0.0 KVA/AMPS: 3.7 13.4 3.7 13.4 3.7 13.4 Mfg/Type: 0.0 3.7 0.0 0.0 A CB Type: 0.0 3.7 0.0 0.0 B Remarks: - Provide Auxiliary Ground Bar and Door in Door Construction 0.0 3.7 0.0 0.0 C VECA Electric PANEL: PNL- 42B -L1 ROOM: SDC 42 UPS ROOM FEED -THRU: TM 603376 LOADS FROM: XFMR- 42B -L1 A B C RCPT LTG EQP HEAT CKT DESCRIPTION PH AMP P KVA AMPS KVA AMPS KVA AMPS 0.2 1 RECEPTACLE IN SDC 42 UPS ROOM A 20 1 0.2 1.5 0.2 3 RECEPTACLE IN SDC 42 GEN ROOM B 20 1 0.2 1.7 AMP: 100 0.2 5 ALC CONTROLLER IN UPS ROOM C 20 1 0.2 1.7 VOLTS: 120 0.2 7 RECEPTACLE IN SDC 42 MECH. SPACE A 20 1 0.2 1.7 208 0.2 9 RECEPTACLE IN SDC 42 MECH. SPACE B 20 1 0.2 1.7 PH: s 3 0.2 11 ROOF RECEPTACLE C 20 1 0.2 1.7 WIRE: 4 0.8 13 ROOF LIGHTING CIRCUIT A 20 1 0.8 6.7 BUS: CU 0.5 15 DAY TANK DT-42B B 20 1 0.5 4.2 A.I.C.: 22K 0.8 17 ROOF LIGHTING CIRCUIT (TEMP) C 20 1 0.8 6.7 MLO: NO 0.2 19 ROOF RECEPTACLE (TEMP) A 20 1 0.2 1.7 MCB: YES 21 B 20 1 0.0 0.0 3R: NO 23 C 20 1 0.0 0.0 FLUSH: NO 25 A 20 1 0.0 0.0 SURF: YES 27 B 20 1 0.0 0.0 29 C 20 1 0.0 0.0 31 A 20 1 0.0 0.0 IG GRND NO 33 B 20 1 0.0 0.0 200% N: NO 1.1 35 GENERATOR 42B BATTERY CHARGER C 20 2 1.1 9.2 FD THRU NO 1.1 37 GENERATOR 42B BATTERY CHARGER A 20 2 1.1 9.2 DBL LUG NO 2.2 39 GENERATOR 42B BLOCK HEATER B 30 2 2.2 18.3 TOP: YES 2.2 41 GENERATOR 426 BLOCK HEATER C 30 2 2.2 18.3 BTM: YES 0.7 2 CP -42B1 -1st Floor UPS Room A 20 1 0.7 . 5.8 PANEL T.C.L. 0.4 4 SUITE 42 -01 G.P. RECEPTACLES B 20 1 0.4 3.0 LOAD (kVA) 0.4 6 SUITE 42 -02 G.P. RECEPTACLES C 20 1 0.4 3.0 RCPT 5.5 0.4 8 SUITE 42 -03 G.P. RECEPTACLES A 20 1 0.4 3.0 LTG 1.6 10 B 20 1 0.0 0.0 EQP 7.8 12 C 20 1 0.0 0.0 HEAT 0.0 14 A 20 1 0.0 0.0 i 16 B 20 1 0.0 0.0 TOTAL 14.9 18 C 20 1 0.0 0.0 c 20 A 20 1 0.0 0.0 FEEDER T.C.L. fi 22 B 20 1 0.0 0.0 LOAD (kVA) 24 C 20 1 0.0 0.0 RCPT 5.5 26 A 20 1 0.0 0.0 LTG 1.6 28 B 20 1 0.0 0.0 EQP 7.8 30 C 20 1 0.0 0.0 HEAT 0.0 32 A 20 1 0.0 0.0 34 B 20 1 0.0 0.0 TOTAL 14.9 36 C 20 1 0.0 0.0 LG MTR 1.0 38 HEAT TRACE CKT ROOF (TEMP) A 20 1 1.0 8.3 FEEDER DEMAND 1.0 40 HEAT TRACE CKT ROOF CH -42B1 & B2 B 20 1 1.0 8.3 kVA 15.3 1.0 42 HEAT TRACE CKT UPS ROOM C 20 1 1.0 8.3 AMPS 42.4 - A 0.0 0.0 - B 0.0 0.0 - C " " 0.0 0.0 5.5 1.6 7.8 0.0 KVA/AMPS: 4.5 37.8 4.5 37.2 5.9 48.8 Mfg/Type: 1.9 0.8 1.8 0.0 A CB Type: 1.8 0.0 2.7 0.0 B Remarks: - Provide Auxillary Ground Bar and Door in Door Construction 1.8 0.8 3.3 0.0 C VECA Electric PANEL: PNL- 42BD2 -L1 ROOM: SDC 42 UPS ROOM FEED -THRU: TM 603376 LOADS FROM: STS- 42 -BD2 A B C RCPT LTG EQP HEAT CKT DESCRIPTION PH AMP P KVA AMPS KVA AMPS KVA AMPS 1 A 50 3 0.0 0.0 3 B 50 3 0.0 0.0 AMP: 225 5 C 50 3 0.0 0.0 VOLTS: 277 7 A 20 3 0.0 0.0 480 9 B 20 3 0.0 0.0 PH: 3 11 C 20 1 0.0 0.0 WIRE: 4 13 A 20 1 0.0 0.0 BUS: CU 15 B 20 1 0.0 0.0 A.I.C.: 22K 17 C 20 1 0.0 0.0 MLO: NO 19 A 20 1 0.0 0.0 MCB: YES 21 B 20 1 0.0 0.0 3R: NO 23 C 20 1 0.0 0.0 FLUSH: NO 25 A 20 1 0.0 0.0 SURF: YES 27 B 20 1 0.0 0.0 29 C 20 1 0.0 0.0 31 A 20 1 0.0 0.0 IG GRND NO 33 B 20 1 0.0 0.0 200% N: NO 35 C 20 1 0.0 0.0 FD THRU YES 37 A 20 1 0.0 0.0 DBL LUG NO 39 B 30 2 0.0 0.0 TOP: YES 41 C 30 2 0.0 0.0 BTM: YES 2 A 20 1 0.0 0.0 PANEL T.C.L. 4 B 20 1 0.0 0.0 LOAD (kVA) 6 C 20 1 0.0 0.0 RCPT 0.0 8 A 20 1 0.0 0.0 LTG 0.0 10 B 20 1 0.0 0.0 EQP 0.0 12 C 20 1 0.0 0.0 HEAT 0.0 14 A 20 1 0.0 0.0 i 16 B 20 1 0.0 0.0 TOTAL 0.0 18 C 20 1 0.0 0.0 c 20 A 20 1 0.0 0.0 FEEDER T.C.L. fi 22 B 20 1 0.0 0.0 LOAD (kVA) 24 C 20 1 0.0 0.0 RCPT 0.0 26 A 20 1 0.0 0.0 LTG 0.0 28 B 20 1 0.0 0.0 EQP 0.0 30 C 20 1 0.0 0.0 HEAT 0.0 32 A 20 1 0.0 0.0 34 B 20 1 0.0 0.0 TOTAL 0.0 36 C 20 1 0.0 0.0 LG MTR 38 A 20 1 0.0 0.0 FEEDER DEMAND 40 B 20 1 0.0 0.0 kVA 0.0 42 C 20 1 0.0 0.0 AMPS 0.0 - A 0.0 0.0 - B 0.0 0.0 - C 0.0 0.0 0.0 0.0 0.0 0.0 KVA/AMPS: 0.0 0.0 0.0 0.0 0.0 0.0 Mfg/Type: 0.0 0.0 0.0 0.0 A CB Type: 0.0 0.0 0.0 0.0 B Remarks: - Provide Auxillary Ground Bar and Door in Door Construction 0.0 0.0 0.0 0.0 C VECA Electric SWBD HDP -42C ROOM: SDC 42 MAIN ELEC ROOM TM 603376 LOAD DISTRIBUTION FROM: UNIT SUBSTATION HVS -42C RCPT LTG EQP HEAT BRKR DESCRIPTION AMP P kVA AMPS 0.0 0.0 475.0 0.0 1 UPS 42 -C1 PRIMARY 1200 3 475 571 2 - - AMP: 4000 3 MBP -42 -C1 MAINT BYPASS 1200 3 - - VOLTS: 0.0 0.0 475.0 0.0 4 UPS 42 -C2 PRIMARY 1200 3 475 571 480 5 - - PHASE: 3 6 MBP -42 -C2 MAINT BYPASS 1200 3 - - WIRE: 3 7 CH -42D1 -Roof Chiller (TEMP AND REDUNDANT) 800 3 - - BUS: CU 8 CHP -42D1 -Roof Pump (TEMP AND REDUNDANT) 60 3 - - A.I.C.: 65K 9 - - M.L.O.: NO 10 UPS 42 -C3 PRIMARY 350 3 - - MAIN CB: YES 11 UPS 42 -C3 STATIC BYPASS 350 3 - - FUSE: NO 12 MBP -42 -C3 MAINT BYPASS 350 3 - - FLUSH: NO 13 M-42C MECH 2500 3 - - SURF: YES 0.0 10.3 0.0 0.0 14 PNL- 42C -I-l1 VIA XFMR- 42C -H1 70 3 10 12 3.4 0.8 6.7 0.0 15 PNL- 42C -L1 VIA XFMR- 42C -L1 50 3 11 13 16 TVSS 100 3 - - IG GND: NO 17 - - 200% N: NO 18 - - FD THRU: NO 19 - - DBL LUG: NO 39.0 20 RF -42C1 -2nd Floor Mechanical Room 80 39 47 TOP: YES 39.0 21 RF -42C2 -2nd Floor Mechanical Room 80 3 39 47 BTM: NO 39.0 22 RF -42C3 -2nd Floor Mechanical Room 80 3 39 47 80.0 23 AHU -42C1 -2nd Floor Mechanical Room 150 3 80 96 PANEL T.C.L. 80.0 24 AHU -42C2 -2nd Floor Mechanical Room 150 3 80 96 LOAD (kVA) 25 SPARE 1200 3 - - RCPT 3 26 SPARE 800 3 - - LTG 11 27 SPARE 150 3 - - EQP 2,350 28 SPARE 100 3 - - HEAT - 29 SPARE 60 3 - - 60.0 30 CRAC -42D1 (TEMP) 100 3 60 72 TOTAL 2,385 31 - - 20.0 32 25% OF LARGEST MOTOR 20 24 FEEDER T.C.L. 33 - - LOAD (kVA) 485.0 34 CH -42C1 -Roof Chiller 800 3 485 583 RCPT 3 485.0 35 CH -42C2 -Roof Chiller 800 3 485 583 LTG 11 22.0 36 CHP -42C1 -Roof Pump 60 3 22 26 EQP 2,350 22.0 37 CHP -42C2 -Roof Pump 60 3 22 26 HEAT - 12.5 38 CRAC -42C1 -1st Floor UPS Room 20 3 13 15 5.0 39 EF -42C1 -1st Floor Generator Room 20 3 5 6 TOTAL 2,365 5.0 40 TF -C1 -1st Floor Generator Room 20 3 5 6 41 - - FEEDER DEMAND 42 - - kVA 2,367 TOTAL 2,365 2,844 AMPS 2,848 3 11 2,350 - MFG: CB: NOTE: Provide IR Scan Windows and Compression Lugs for Incoming Feeders Feede T.C.L. is printed here horizontally to allow a block "paste -link" to the "Load Distribution" columns of a sub - feed panel or switchboard. I 1 I Project: SDC -42 Phase I 02/04/11 VECA Electric SWBD MBP -42 -C1 ROOM: SDC 42 MAIN ELEC ROOM TM 603376 LOAD DISTRIBUTION FROM: UPS -42 -C1 / HDP -42C RCPT LTG EQP HEAT BRKR DESCRIPTION AMP P kVA AMPS 237.5 1 STS- 42 -CB1 PRIMARY 800 3 238 286 2 STS- 42 -BC1 SECONDARY 800 3 - - AMP: 1200 237.5 3 STS- 42 -CD1 PRIMARY 800 3 238 286 VOLTS: 4 STS- 42 -DC1 SECONDARY 800 3 - - 480 5 SPARE 800 3 - - PHASE: 3 6 SPARE 800 3 - - WIRE: 3 7 SPARE 800 3 - - BUS: CU 8 SPARE 800 3 - - A.I.C.: 65K - - M.L.O.: _ - - MAIN CB: NO - - FUSE: NO - - FLUSH: NO - - SURF: YES - - IG GND: NO - - 200% N: NO - - FD THRU: YES - - DBL LUG: YES - - TOP: YES - - BTM: WA , - - PANEL T.C.L. - - LOAD (kVA) - - RCPT - - - LTG - - - EQP 475 - - HEAT - - - TOTAL 475 - - FEEDER T.C.L. - - LOAD (kVA) - RCPT - - - LTG - - - EQP 475 - - HEAT - - - TOTAL 475 - - FEEDER DEMAND - - kVA 475 TOTAL 475 571 AMPS 571 - - 475 - MFG: CB: NOTE: Provide Compression Lugs for Incoming Feeders Feede T.C.L. is printed here horizontally to allow a block 'paste -link" to the "Load Distribution" columns of a sub - feed panel or switchboard. I I I Project: SDC -42 Phase I 02/04/11 if • VECA Electric SWBD MB P-42-C2 ROOM: SDC 42 MAIN ELEC ROOM TM 603376 LOAD DISTRIBUTION FROM: UPS -42 -C2 / HDP -42C RCPT LTG EQP HEAT BRKR DESCRIPTION AMP P kVA AMPS 237.5 1 STS- 42 -CB2 PRIMARY 800 3 238 286 2 STS- 42 -BC2 SECONDARY 800 3 - - AMP: 1200 237.5 3 STS- 42 -CD2 PRIMARY 800 3 238 286 VOLTS: 4 STS- 42 -DC2 SECONDARY 800 3 - - 480 5 SPARE 800 3 - - PHASE: 3 6 SPARE 800 3 - - WIRE: 3 7 SPARE 800 3 - - BUS: CU 8 SPARE 800 3 - - A.I.C.: 65K - - M.L.O.: - - MAIN CB: NO - FUSE: NO - FLUSH: NO - - SURF: YES - - IG GND: NO - - 200% N: NO - - FD THRU: YES - - DBL LUG: YES - - TOP: YES - - BTM: WA - - PANEL T.C.L. - - LOAD (kVA) - - RCPT - - - LTG - - - EQP 475 - - HEAT - - - TOTAL 475 - - FEEDER T.C.L. - - LOAD (kVA) - - RCPT - - - LTG - - - EQP 475 - HEAT - - - TOTAL 475 - - FEEDER DEMAND - - kVA 475 TOTAL 475 571 AMPS 571 - - 475 - MFG: CB: NOTE: Provide Compression Lugs for Incoming Feeders Feeder T.C.L. is printed here horizontally to allow a block "paste -link" to the "Load Distribution" columns of a sub - feed panel or switchboard. I I I Project: SDC -42 Phase I 02/04/11 VECA Electric PANEL: PNL- 42C-H1 ROOM: SDC 42 UPS ROOM FEED -THRU: TM 603376 LOADS FROM: HDP -42C VIA XFMR 42C -H1 A B C RCPT LTG EQP HEAT CKT DESCRIPTION PH AMP P KVA AMPS KVA AMPS KVA AMPS 1.7 1 UPS ROOM LIGHTING A 20 1 1.7 6.1 1.7 3 GENERATOR ROOM LIGHTING B 20 1 1.7 6.1 AMP: 100 0.9 5 MECHANICAL RM LIGHTING C 20 1 0.9 3.2 VOLTS: 277 2.0 7 SUITE 42 -01 LIGHTING A 20 1 2.0 7.2 480 2.0 9 SUITE 42 -02 LIGHTING B 20 1 2.0 7.2 PH: 3 2.0 11 SUITE 42 -03 LIGHTING C 20 1 2.0 7.2 WIRE: 4 13 A 20 1 0.0 0.0 BUS: CU 15 B 20 1 0.0 0.0 A.I.C.: 65K 17 C 20 1 0.0 0.0 MLO: NO 19 A 20 1 0.0 0.0 MCB: YES 21 B 20 1 0.0 0.0 3R: NO 23 C 20 1 0.0 0.0 FLUSH: NO 25 A 20 1 0.0 0.0 SURF: YES 27 B 20 1 0.0 0.0 29 C 20 1 0.0 0.0 0.0 0.0 IG GRND NO 0.0 0.0 200% N: NO 0.0 0.0 FD THRU NO 0.0 0.0 DBL LUG NO 0.0 0.0 TOP: YES 0.0 0.0 BTM: YES 2 A 20 1 0.0 0.0 PANEL T.C.L. 4 B 20 1 0.0 0.0 LOAD (kVA) 6 C 20 1 0.0 0.0 RCPT 0.0 8 A 20 1 0.0 0.0 LTG 10.3 10 B 20 1 0.0 0.0 EQP 0.0 12 C 20 1 0.0 0.0 HEAT 0.0 14 A 20 3 0.0 0.0 i 16 B 0.0 0.0 TOTAL 10.3 18 C 0.0 0.0 c 20 A 30 3 0.0 0.0 FEEDER T.C.L. ti 22 B 0.0 0.0 LOAD (kVA) 24 C 0.0 0.0 RCPT 0.0 26 A 50 3 0.0 0.0 LTG 10.3 28 B 0.0 0.0 EQP 0.0 30 C 0.0 0.0 HEAT 0.0 0.0 0.0 0.0 0.0 TOTAL 10.3 0.0 0.0 LG MTR 0.0 0.0 FEEDER DEMAND 0.0 0.0 kVA 12.9 0.0 0.0 AMPS 15.5 - A 0.0 0.0 - B 0.0 0.0 - C 0.0 0.0 0.0 10.3 0.0 0.0 KVA/AMPS: 3.7 13.4 3.7 13.4 2.9 10.5 Mfg/Type: 0.0 3.7 0.0 0.0 A CB Type: 0.0 3.7 0.0 0.0 B Remarks: - Provide Auxiliary Ground Bar and Door in Door Construction 0.0 2.9 0.0 0.0 C VECA Electric PANEL: PNL- 42C-L1 ROOM: SDC 42 UPS ROOM FEED -THRU: TM 603376 LOADS FROM: HDP -42C VIA XFMR- 42C -L1 A B C RCPT LTG EQP HEAT CKT DESCRIPTION PH AMP P KVA AMPS KVA AMPS KVA AMPS 0.2 1 RECEPTACLE IN SDC 42 UPS ROOM A 20 1 0.2 1.5 0.2 3 RECEPTACLE IN SDC 42 GEN ROOM B 20 1 0.2 1.7 AMP: 100 0.2 5 ALC CONTROLLER IN UPS ROOM C 20 1 0.2 1.7 VOLTS: 120 0.2 7 RECEPTACLE IN SDC 42 MECH. SPACE A 20 1 0.2 1.7 208 0.2 9 RECEPTACLE IN SDC 42 MECH. SPACE B 20 1 0.2 1.7 PH: 3 0.2 11 ROOF RECEPTACLE C 20 1 0.2 1.7 WIRE: 4 0.8 13 ROOF LIGHTING CIRCUIT A 20 1 0.8 6.7 BUS: CU 0.5 15 DAY TANK DT -52C B 20 1 0.5 4.2 A.I.C.: 22K 17 C 20 1 0.0 0.0 MLO: YES 19 A 20 1 0.0 0.0 MCB: NO 21 B 20 1 0.0 0.0 3R: NO 23 C 20 1 0.0 0.0 FLUSH: NO 25 A 20 1 0.0 0.0 SURF: YES 27 B 20 1 0.0 0.0 29 C 20 1 0.0 0.0 31 A 20 1 0.0 0.0 IG GRND NO 33 B 20 1 0.0 0.0 200% N: NO 35 C 20 1 0.0 0.0 FD THRU NO 1.1 37 GENERATOR 42C BATTERY CHARGER A 20 1 1.1 9.2 DBL LUG NO 2.2 39 GENERATOR 42C BLOCK HEATER B 30 2 2.2 18.3 TOP: YES 2.2 41 GENERATOR 42C BLOCK HEATER C 30 2 2.2 18.3 BTM: YES 0.7 2 CP -42C1 -1st Floor UPS Room A 20 1 0.7 5.8 PANEL T.C.L. 0.4 4 SUITE 42 -01 G.P. RECEPTACLES B 20 1 0.4 3.3 LOAD (kVA) 0.4 6 SUITE 42 -02 G.P. RECEPTACLES C 20 1 0.4 3.3 RCPT 3.4 0.4 8 SUITE 42 -03 G.P. RECEPTACLES A 20 1 0.4 3.3 LTG 0.8 10 B 20 1 0.0 0.0 EQP 6.7 12 C 20 1 0.0 0.0 HEAT 0.0 14 A 20 1 0.0 0.0 i 16 B 20 1 0.0 0.0 TOTAL 10.9 18 C 20 1 0.0 0.0 c 20 A 20 1 0.0 0.0 FEEDER T.C.L. fi 22 B 20 1 0.0 0.0 LOAD (kVA) 24 C 20 1 0.0 0.0 RCPT 3.4 26 A 20 1 0.0 0.0 LTG 0.8 28 B 20 1 0.0 0.0 EQP 6.7 30 C 20 1 0.0 0.0 HEAT 0.0 32 A 20 1 0.0 0.0 ' 34 B 20 1 0.0 0.0 TOTAL 10.9 36 C 20 1 0.0 0.0 LG MTR 38 A 20 1 0.0 0.0 FEEDER DEMAND 1.0 40 HEAT TRACE CH -42D1 & D2 (TEMP) B 20 1 1.0 8.3 kVA 11.1 42 C 20 1 0.0 0.0 AMPS 30.8 - A 0.0 0.0 - B 0.0 0.0 - C " " 0.0 0.0 3.4 0.8 6.7 0.0 KVA/AMPS: 3.4 28.2 4.5 37.5 3.0 25.0 Mfg/Type: 0.8 0.8 1.8 0.0 A CB Type: 1.8 0.0 2.7 0.0 B Remarks: - Provide Auxiliary Ground Bar and Door in Door Construction 0.8 0.0 2.2 0.0 C VECA Electric SWBD HDP -42D ROOM: SDC 42 MAIN ELEC ROOM TM 603376 LOAD DISTRIBUTION FROM: UNIT SUBSTATION HVS -42D RCPT LTG EQP HEAT BRKR DESCRIPTION AMP P kVA AMPS 0.0 0.0 475.0 0.0 1 UPS 42 -D1 PRIMARY 1200 3 475 571 2 - - AMP: 4000 3 MBP -42 -D1 MAINT BYPASS 1200 3 - - VOLTS: 0.0 0.0 475.0 0.0 4 UPS 42 -D2 PRIMARY 1200 3 475 571 480 5 - - PHASE: 3 6 MBP -42 -D2 MAINT BYPASS 1200 3 - - WIRE: 3 7 - - BUS: CU 8 - - A.I.C.: 65K 9 - - M.L.O.: NO 10 UPS 42 -D3 PRIMARY (FUTURE) 350 3 - - MAIN CB: YES 11 UPS 42 -D3 STATIC BYPASS (FUTURE) 350 3 - - FUSE: NO 12 MBP -42 -D3 MAINT BYPASS (FUTURE) 350 3 - - FLUSH: NO 13 M-42D MECH 2500 3 - - SURF: YES 0.0 0.0 0.0 0.0 14 PNL- 42D -H1 VIA XFMR- 42D -H1 70 3 - - 2.8 0.0 7.1 0.0 15 PNL- 42D -L1 VIA XFMR- 42D -L1 50 3 10 12 16 TVSS 100 3 - - IG GND: NO 17 - - 200% N: NO 18 - - FD THRU: NO 19 - - DBL LUG: NO 39.0 20 RF -42D1 -2nd Floor Mechanical Room 80 3 39 47 TOP: YES 39.0 21 RF -42D2 -2nd Floor Mechanical Room 80 3 39 47 BTM: NO 39.0 22 RF -42D3 -2nd Floor Mechanical Room 80 3 39 47 80.0 23 AHU -42D1 -2nd Floor Mechanical Room 150 3 80 96 PANEL T.C.L. 80.0 24 AHU -42D2 -2nd Floor Mechanical Room 150 3 80 96 LOAD (kVA) 25 SPARE 1200 3 - - RCPT 3 26 800 3 - - LTG - 27 SPARE 150 3 - - EQP 2,281 28 SPARE 100 3 - - HEAT - 29 SPARE 60 3 - - 30 - - TOTAL 2,283 31 - - 20.0 32 25% OF LARGEST MOTOR 20 24 FEEDER T.C.L. 33 - - LOAD (kVA) 485.0 34 CH -42D1 -Roof Chiller 800 3 485 583 RCPT 3 485.0 35 CH -42D2 -Roof Chiller 800 3 485 583 LTG - 22.0 36 CHP -42D1 -Roof Pump 60 3 22 26 EQP 2,281 22.0 37 CHP -42D2 -Roof Pump 60 3 22 26 HEAT - 12.5 38 CRAC -42D1 -1st Floor UPS Room 20 3 13 15 39 - - TOTAL 2,283 40 - - 41 - - FEEDER DEMAND 42 - - kVA 2,283 TOTAL 2,283 2,746 AMPS 2,748 3 - 2,281 - MFG: CB: NOTE: Provide IR Scan Windows and Compression Lugs for Incoming Feeders Feede T.C.L. is panted here horizontally to allow a block "paste- link" to the "Load Distribution" columns of a sub - feed panel or switchboard. I I I Project: SDC -42 Phase I 02/04/11 VECA Electric SWBD MBP -42 -D1 ROOM: SDC 42 MAIN ELEC ROOM TM 603376 LOAD DISTRIBUTION FROM: UPS -42 -D1 / HDP -42D RCPT LTG EQP HEAT BRKR DESCRIPTION AMP P kVA AMPS 237.5 1 STS- 42 -DB1 PRIMARY 800 3 238 286 2 STS- 42 -BD1 SECONDARY 800 3 - - AMP: 1200 237.5 3 STS- 42 -DC1 PRIMARY 800 3 238 286 VOLTS: 4 STS- 42 -CD1 SECONDARY 800 3 - - 480 5 SPARE 800 3 - - PHASE: 3 6 SPARE 800 3 - - WIRE: 3 7 SPARE 800 3 - - BUS: CU 8 SPARE 800 3 - - A.I.C.: 65K - - M.L.O.: - - MAIN CB: NO - - FUSE: NO - - FLUSH: NO - - SURF: YES - - IG GND: NO - - 200% N: NO - - FD THRU: YES - - DBL LUG: YES - - TOP: YES - - BTM: WA - - PANEL T.C.L. - - LOAD (kVA) - - RCPT - - - LTG - - - EQP 475 - - HEAT - - - TOTAL 475 - - FEEDER T.C.L. - - LOAD (kVA) - - RCPT - - - LTG - - - EQP 475 - - HEAT - - - TOTAL 475 - - FEEDER DEMAND - - kVA 475 TOTAL 475 571 AMPS 571 - - 475 - MFG: CB: NOTE: Provide Compression Lugs for Incoming Feeders Feede T.C.L. is printed here horizontally to allow a block "paste -link" to the "Load Distribution" columns of a sub - feed panel or switchboard. I I I Project: SDC -42 Phase I 02/04/11 • • VECA Electric SWBD MBP -42 -D2 ROOM: SDC 42 MAIN ELEC ROOM TM 603376 LOAD DISTRIBUTION FROM: UPS -42 -D2 / HDP -42D RCPT LTG EQP HEAT BRKR DESCRIPTION AMP P kVA AMPS 237.5 1 STS- 42 -DB2 PRIMARY 800 3 238 286 2 STS- 42 -BD2 SECONDARY 800 3 - - AMP: 1200 237.5 3 STS- 42 -DC2 PRIMARY 800 3 238 286 VOLTS: 4 STS- 42 -CD2 SECONDARY 800 3 - - 480 5 SPARE 800 3 - - PHASE: 3 6 SPARE 800 3 - - WIRE: 3 7 SPARE 800 3 - - BUS: CU 8 SPARE 800 3 - - A.I.C.: 65K - - M.L.O.: - - MAIN CB: NO - - FUSE: NO - - FLUSH: NO - - SURF: YES - - IG GND: NO - - 200% N: ' NO - - FD THRU: YES - - DBL LUG: YES - - TOP: YES - - BTM: WA - - PANEL T.C.L. - LOAD (kVA) - - RCPT - - LTG - - - EQP 475 - - HEAT - - - TOTAL 475 - - FEEDER T.C.L. - - LOAD (kVA) - - RCPT - - - LTG - - - EQP 475 - - HEAT - - - TOTAL 475 - - FEEDER DEMAND - - kVA 475 TOTAL 475 571 AMPS 571 - - 475 - MFG: CB: NOTE: Provide Compression Lugs for Incoming Feeders Feede T.C.L. is printed here horizontally to allow a block "paste-link" to the "Load Distribution" columns of a sub - feed panel or switchboard. I I I Project: SDC -42 Phase I 02/04/11 VECA Electric PANEL: PNL -42D-H1 ROOM: SDC 42 UPS ROOM FEED -THRU: TM 603376 LOADS FROM: HDP -42D VIA XFMR- 42D -H1 A B C RCPT LTG EQP HEAT CKT DESCRIPTION PH AMP P KVA AMPS KVA AMPS KVA AMPS 1 A 20 1 0.0 0.0 3 B 20 1 0.0 0.0 AMP: 100 5 C 20 1 0.0 0.0 VOLTS: 277 7 A 20 1 0.0 0.0 480 9 B 20 1 0.0 0.0 PH: 3 11 C 20 1 0.0 0.0 WIRE: 4 13 A 20 1 0.0 0.0 BUS: CU 15 B 20 1 0.0 0.0 A.I.C.: 65K 17 C 20 1 0.0 0.0 MLO: NO 19 A 20 1 0.0 0.0 MCB: YES 21 B 20 1 0.0 0.0 3R: NO 23 C 20 1 0.0 0.0 FLUSH: NO 25 A 20 1 0.0 0.0 SURF: YES 27 B 20 1 0.0 0.0 29 C 20 1 0.0 0.0 0.0 0.0 IG GRND NO 0.0 0.0 200% N: NO 0.0 0.0 FD THRU NO 0.0 0.0 DBL LUG NO 0.0 0.0 TOP: YES 0.0 0.0 BTM: YES 2 A 20 1 0.0 0.0 PANEL T.C.L. 4 B 20 1 0.0 0.0 LOAD (kVA) 6 C 20 1 0.0 0.0 RCPT 0.0 8 A 20 1 0.0 0.0 LTG 0.0 10 B 20 1 0.0 0.0 EQP 0.0 12 C 20 1 0.0 0.0 HEAT 0.0 14 A 20 3 0.0 0.0 1 16 B 0.0 0.0 TOTAL 0.0 18 C 0.0 0.0 c 20 A 30 3 0.0 0.0 FEEDER T.C.L. fi 22 B 0.0 0.0 LOAD (kVA) 24 C " " 0.0 0.0 RCPT 0.0 26 A 50 3 0.0 0.0 LTG 0.0 28 B 0.0 0.0 EQP 0.0 30 C " " 0.0 0.0 HEAT 0.0 0.0 0.0 0.0 0.0 TOTAL 0.0 0.0 0.0 LG MTR 0.0 0.0 FEEDER DEMAND 0.0 0.0 kVA 0.0 0.0 0.0 AMPS 0.0 - A 0.0 0.0 - B 0.0 0.0 - C " " 0.0 0.0 0.0 0.0 0.0 0.0 KVA/AMPS: 0.0 0.0 0.0 0.0 0.0 0.0 Mfg/Type: 0.0 0.0 0.0 0.0 A CB Type: 0.0 0.0 0.0 0.0 B Remarks: - Provide Auxiliary Ground Bar and Door in Door Construction 0.0 0.0 0.0 0.0 C VECA Electric PANEL: PNL-42D -L1 ROOM: SDC 42 UPS ROOM FEED -THRU: TM 603376 LOADS FROM: HDP -42D VIA XFMR- 42D -L1 A B C RCPT LTG EQP HEAT CKT DESCRIPTION PH AMP P KVA AMPS KVA AMPS KVA AMPS 0.2 1 RECEPTACLE IN SDC 42 UPS ROOM A 20 1 0.2 1.5 0.2 3 RECEPTACLE IN SDC 42 GEN ROOM B 20 1 0.2 1.7 AMP: 100 0.2 5 ALC CONTROLLER IN UPS ROOM C 20 1 0.2 1.7 VOLTS: 120 2.0 7 RECEPTACLE IN SDC 42 MECH. SPACE A 20 1 2.0 16.7 208 0.2 9 RECEPTACLE IN SDC 42 MECH. SPACE B 20 1 0.2 1.7 PH: 3 11 ROOF RECEPTACLE C 20 1 0.0 0.0 WIRE: 4 13 ROOF LIGHTING CIRCUIT A 20 1 0.0 0.0 BUS: CU 0.5 15 DAY TANK DT-42D B 20 1 0.5 4.2 A.I.C.: 22K 17 C 20 1 0.0 0.0 MLO: NO 19 A 20 1 0.0 0.0 MCB: YES 21 B 20 1 0.0 0.0 3R: NO 23 C 20 1 0.0 0.0 FLUSH: NO 25 A 20 1 0.0 0.0 SURF: YES 27 B 20 1 0.0 0.0 29 C 20 1 0.0 0.0 31 A 20 1 0.0 0.0 IG GRND NO 33 B 20 1 0.0 0.0 200% N: NO 1.1 35 GENERATOR 42D BATTERY CHARGER C 20 2 1.1 9.2 FD THRU NO 1.1 37 GENERATOR 42D BATTERY CHARGER A 20 2 1.1 9.2 DBL LUG NO 2.2 39 GENERATOR 42D BLOCK HEATER B 30 2 2.2 18.3 TOP: YES 2.2 41 GENERATOR 42D BLOCK HEATER C 30 2 2.2 18.3 BTM: YES 2 A 20 1 0.0 0.0 PANEL T.C.L. 4 B 20 1 0.0 0.0 LOAD (kVA) 6 C 20 1 0.0 0.0 RCPT 2.8 8 A 20 1 0.0 0.0 LTG 0.0 10 B 20 1 0.0 0.0 EQP 7.1 12 C 20 1 0.0 0.0 HEAT 0.0 14 A 20 1 0.0 0.0 1 16 B 20 1 0.0 0.0 TOTAL 9.9 18 C 20 1 0.0 0.0 c 20 A 20 1 0.0 0.0 FEEDER T.C.L. fi 22 B 20 1 0.0 0.0 LOAD (kVA) 24 C 20 1 0.0 0.0 RCPT 2.8 26 A 20 1 0.0 0.0 LTG 0.0 28 B 20 1 0.0 0.0 EQP 7.1 30 C 20 1 0.0 0.0 HEAT 0.0 32 A 20 1 0.0 0.0 34 B 20 1 0.0 0.0 TOTAL 9.9 36 C 20 1 0.0 0.0 LG MTR 38 A 20 1 0.0 0.0 FEEDER DEMAND 40 HEAT TRACE CH -42D1 & D2 (TEMP A) B 20 1 0.0 0.0 kVA 9.9 42 C 20 1 0.0 0.0 AMPS 27.4 - A 0.0 0.0 - B 0.0 0.0 - C 0.0 0.0 2.8 0.0 7.1 0.0 KVA/AMPS: 3.3 27.3 3.1 25.8 3.5 29.2 Mfg/Type: 2.2 0.0 1.1 0.0 A CB Type: 0.4 0.0 2.7 0.0 B Remarks: - Provide Auxiliary Ground Bar and Door in Door Construction 0.2 0.0 3.3 0.0 C p_. PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL11 -0092 DATE: 02 -04 -11 . PROJECT NAME: SABEY DATA CENTER - SDC42 SITE ADDRESS: 3355 S 120 PL X Original Plan Submittal Response to Incomplete Letter. # Response to Correction Letter # Revision # After Permit Issued DEPAR MENTS: rEar Bu (ding ivision Ins Public Works n Fire Prevention Structural n Planning Division n Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 02 -08-11 Complete Incomplete ❑ Not Applicable n Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Approved with Conditions Notation: REVIEWER'S INITIALS: [4 DUE DATE: 03-08 -11 Not Approved (attach comments) n DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 Contractors or Tradespeople Peter Friendly Page 1 Electrical Contractor A business licensed by Lai to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company VECA ELECTRIC CO INC 2064365200 5614 7Th Ave 5 PO BOX 80467 Seattle WA 98108 King Corporation UBI No. 601190731 Status Active License No. VECAECI542MU License Type Electrical Contractor Effective Date 7/31/1946 Expiration Date 10/31/2011 Suspend Date Specialty 1 General Specialty 2 Unused Master Electrician INFORMATION License CONTIK'965D6 Name CONTI, KEITH Status Active Business Owner Information Name Role Effective Date Expiration Date FAIRBANKS, THOMAS Cancel Date 01/01/1980 Bond Amount ALLEN, RON Agent 01/01/1980 929407110 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 7 WESTERN SURETY CO 929407110 01/06/2007 Until Cancelled 19.28.101 RCW ELECTRICAL CITATION $4,000.00 01/06/2007 6 TRAVELERS CAS a SURETY CO 0815103520497 01/06/2001 Until Cancelled 01/06/2007 E54947 $4,000.00 01/05/2001 Assignment of Savings Information No records found for the previous 6 year period Insurance Information No records found for the previous 6 year period Summons /Complaint Information Summons and Complaints are not filed with the department for this contractor type Warrant Information Warrants are not filed with the department for this contractor type Infractions /Citations Information Infraction / Citation Date RCW Code Type Status Violation Amount EBOES00247 5/30/2006 19.28.101 RCW ELECTRICAL CITATION Satisfied $2,000.00 EBOES00447 3/9/2010 19.28.101 RCW ELECTRICAL CITATION Satisfied $250.00 EJONV00207 9/13/2005 19.28.101 RCW ELECTRICAL CITATION Satisfied $1,000.00 E54947 8/8/2005 19.28.161(6) RCW ELECTRICAL CITATION Satisfied $250.00 EMEH000554 4/19/2006 19.28.161(6) RCW ELECTRICAL CITATION Satisfied $250.00 EMEH000552 4/19/2006 19.28.161(6) RCW ELECTRICAL CITATION Satisfied $250.00 EMEH000556 4/19/2006 19.28.161(6) RCW ELECTRICAL CITATION Satisfied $250.00 EMEH000548 4/19/2006 19.28.161(6) RCW ELECTRICAL CITATION Satisfied $250.00 EMEH000561 4/19/2006 19.28.161(6) RCW ELECTRICAL CITATION Satisfied $250.00 https:// fortress .wa.gov /lni/bbip/Print.aspx 02/28/2011 F E D A 1 2 3 4 5 6 7 8 9 10 SABEY DATA CENTER SDC42 ELECTRICAL INDEX SHEET SHEET NUMBER TITLE E0.0 ELECTRICAL COVER SHEET E0.01 ELECTRICAL SYMBOLS LEGEND E0.02 ELECTRICAL ABBREVIATIONS & SYSTEM SUMMARY E0.03 PRETASK PLANNING E1.10 1ST FLOOR OVERALL ELECTRICAL LAYOUT E1.11 1ST FLOOR UPS ROOM LAYOUT E1.12 1ST FLOOR GENERATOR ROOM LAYOUT E2.11 LEVEL 1 POWER PLAN E2.11 M LEVEL 1 MECHANICAL POWER PLAN E2.21 LEVEL 2 POWER PLAN E2.21 M LEVEL 2 MECHANICAL POWER PLAN E2.22 LEVEL 2 SUITE POWER PLAN E2.R1 ROOFTOP POWER PLAN E2.R1 M ROOFTOP MECHANICAL POWER PLAN E3.11 LEVEL 1 UPS ROOM LIGHTING LAYOUT E3.12 LEVEL 1 GENERATOR ROOM LIGHTING LAYOUT E321 'LEVEL 2 MECHANICAL SPACE LIGHTING LAYOUT LEVEL 2. SUITE 42 -01, 42- 02,,42 -D3 LIGHTING LAYOUT E3.R1 ROOFTOP LIGHTING LAYOUT E5.00 MECHANICAL EQUIPMENT CONNECTION SCHEDULE E5.11 ONELINE DIAGRAM E5.12 ONELINE DIAGRAM E5.13 ONELINE DIAGRAM SEPARATE PERMIT REQUIRED FOR: @Mechanical ❑ Electrical WL umbing as Piping City of Tukwila 9_wDING DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOT7.: Revisions will require a new plan submittal and may include additional plan review fees. FILE COPY Permit No.. tiii-k•-•0097ft Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize is c. violation of any adopted code or ordinance. Receipt of approved Field y and ti is acknowledged: By 4 Date: L. /2 s /I City Of DIVISION DIV-0 12 REVIEWED .F0R COMPLIANCE WITH NFPA7O -NEC FEB 17 2011 City of Tukwila BUILDING DIVISION RECEIVED FEB 0 4 2011 PERMIT CENTER W z ONSULTANT w Z5 0 J 0 z 2 0 W 0 1- 0 W ..I 0 T E 0 O ti O) U c0 0 > T N N CO 00 .Q N N co CO CO CO 0 0 N N 3 co 0 T c °)E o 0 >0 0 < OD c CO'CO N-03 >. O °O • c0 a) 0) TM 603376 NTERGATE EAST CAMPUS w U 2 0 C\1 Cr) LO M M CO 00 rn ca PROJECT #210252.06 ISSUED / REVISED DATE PROGRESS DRAWING 4/29/10 REVIEW SET 1/14/11 PERMIT SET 1/28/11 PHASE 42 INDEX SHEET E0.00 10 BUILDING NORTH REFERENCE SYMBOLS DESCRIPTION EGEND SYMBOL PLAN DIAGRAM SYMBOLS LEGEND - LIGHTING DETAIL SYMBOL A- IDENTIFYING NUMBER B -SHEET WHERE DETAIL IS SHOWN ELEVATION OR SECTION SYMBOL A- IDENTIFYING NUMBER B -SHEET WHERE DETAIL IS SHOWN NORTH ARROW EQUIPMENT IDENTIFICATION SYMBOL. REFER TO EQUIPMENT SCHEDULE. REFERENCE NOTE TAG SYMBOL A - NOTE NUMBER LIGHTING FIXTURE IDENTIFICATION SYMBOL. REFER TO LIGHTING FIXTURE SCHEDULE. POWER RACEWAY /CABLE IDENTIFICATION SYMBOL REVISION SYMBOL REFERENCE PHOTO NUMBER & DIRECTION CONTROL RACEWAY IDENTIFICATION SYMBOLS LEGEND - GENERAL DESCRIPTION CONDUCTORS - CONNECTED CONDUCTORS - NOT CONNECTED CONDUIT - CONCEALED IN WALL OR CEILING IN FINISHED AREAS, EXPOSED IN UNFINISHED AREAS CONDUIT - ROUTED UNDERFLOOR OR UNDERGROUND GROUND WIRE LOW- VOLTAGE WIRING SURFACE METAL RACEWAY (SHOWN WITH JUNCTION BOX) FIRST NUMBER INDICATE NUMBER OF RECEPTACLES SECOND NUMBER INDICATES SPACING OF RECEPTACLES IN INCHES EXISTING TO BE REMOVED (CROSS HATCHED) HEAVY LINEWEIGHT INDICATES NEW WORK LIGHT LINEWEIGHT INDICATES EXISTING INFORMATION CONDUIT OR CABLE DOWN CONDUIT OR CABLE UP CONDUIT CAPPED FLEXIBLE CONDUIT HOME RUN - NUMBER OF CONDUCTORS AS INDICATED SMALL HASH MARKS INDICATE PHASE CONDUCTORS LARGER HASH MARKS INDICATES NEUTRAL BACKSLASH INDICATES GROUND WIRE BACKSLASH WITH DOT INDICATES ISOLATED GROUND ALL UNMARKED CONDUIT RUNS ARE 1/2" CONDUIT WITH 2 #12 & 1 #12 GND, UNLESS NOTED OTHERWISE. SINGLE -POLE SWITCH SWITCH LOWER CASE LEI I ER INDICATES SWITCHING GROUP SUBSCRIPT INDICATES: 2 2 -POLE 3 3 -WAY 4 4 -WAY D DIMMER WP WEATHERPROOF LV LOW- VOLTAGE K KEYED OS OCCUPANCY SENSOR T TIMER HOA HAND -OFF -AUTO JUNCTION BOX SYMBOLS LEGEND - GROUNDING GROUND CONNECTION GROUND ROD GROUND WELL DESCRIPTION 6a,b i® I 1 0 1 0 1 0 O 10- Fa n o1 0 0 oc P DT H ICS1 -1 7 PS 4 CR DESCRIPTION LIGHTING FIXTURE ADJACENT NUMBER INDICATES CIRCUIT GROUPING LOWER CASE LETTER INDICATES SWITCHING GROUP "NL" ADJACENT TO FIXTURE INDICATES NIGHT LIGHT SURFACE - MOUNTED FLUORESCENT LIGHTING FIXTURE WITH JUNCTION BOX - TYPE AS NOTED, SIZE AS SHOWN RECESS - MOUNTED FLUORESCENT LIGHTING FIXTURE WITH JUNCTION BOX - TYPE AS NOTED, SIZE AS SHOWN RECESS - MOUNTED, LAY -IN, FLUORESCENT LIGHTING FIXTURE (TROFFER) - TYPE AS NOTED, SIZE AS SHOWN SHADING INDICATES EGRESS LUMINAIRE ON EMERGENCY CIRCUIT OR WITH BATTERY BACKUP BALLAST (TYPICAL) PENDANT - MOUNTED FLUORESCENT LIGHTING FIXTURE - TYPE AS NOTED, SIZE AS SHOWN (CEILING MOUNTED J -BOX SHOWN) WALL - MOUNTED FLUORESCENT LIGHTING FIXTURE - TYPE AS NOTED, SIZE AS SHOWN RECESSED, WALL - MOUNTED FLUORESCENT LIGHTING FIXTURE WITH JUNCTION BOX - TYPE AS NOTED STRIP FLUORESCENT LIGHTING FIXTURE - TYPE AS NOTED STRIP FLUORESCENT LIGHTING FIXTURE ON EMERGENCY CIRCUIT - TYPE AS NOTED STAGGERED STRIP FLUORESCENT FIXTURE - TYPE AS NOTED WALL - MOUNTED LIGHTING FIXTURE - TYPE AS NOTED WALL - MOUNTED LIGHTING FIXTURE ON EMERGENCY CIRCUIT - TYPE AS NOTED WALL WASH FIXTURE - TYPE AS NOTED PENDANT - MOUNTED LIGHTING FIXTURE - TYPE AS NOTED CEILING - MOUNTED LIGHTING FIXTURE - TYPE AS NOTED CEILING- MOUNTED LIGHTING FIXTURE ON EMERGENCY CIRCUIT - TYPE AS NOTED DIRECTIONAL LIGHTING FIXTURE - TYPE AS NOTED DIRECTIONAL LIGHTING FIXTURE - TYPE AS NOTED INDICATING LIGHT - TYPE AS NOTED A- AMBER; B -BLUE; G- GREEN; R -RED; W -WHITE TRACK LIGHT - TYPE AS NOTED NUMBER OF HEADS AS SHOWN FLEXIBLE TRACK LIGHT TYPE AS NOTED NUMBER OF HEADS AS SHOWN RECESSED TRACK LIGHT - TYPE AS NOTED NUMBER OF HEADS AS SHOWN ILLUMINATED. EXIT SIGN - SINGLE FACE ARROW INDICATES DIRECTION OF EGRESS ILLUMINATED EXIT SIGN - DUAL FACE WALL MOUNTED ILLUMINATED EXIT SIGN - SINGLE FACE WALL MOUNTED SELF CONTAINED EMERGENCY LIGHT COMBINATION SELF CONTAINED EMERGENCY WALLPACK /EXIT LIGHT POLE- MOUNTED LIGHTING FIXTURE TYPE AS NOTED NUMBER OF FIXTURES AS SHOWN EXTERIOR HUMAN SCALE LUMINAIRE, TYPE AS NOTED EXTERIOR LANDSCAPE LUMINAIRE, TYPE AS NOTED EXTERIOR STEP LIGHTING FIXTURE - TYPE AS NOTED PHOTOELECTRIC CONTROL - CEILING MOUNTED ADJACENT LETTER P INDICATES PENDANT MOUNTED OCCUPANCY SENSOR - CEILING MOUNTED ADJACENT LEI IER W INDICATES WALL MOUNTED U - ULTRASONIC IR - PASSIVE INFRARED DT - DUAL TECHNOLOGY ILLUMINATION CONTROL STATION WITH DESIGNATION CONTACTOR SUBSCRIPT INDICATES NUMBER OF POLES CONTACT NUMBER INDICATES. REFERENCE LETTER INDICATES FUNCTION RELAY COIL CR- CONTROL RELAY; TD -TIME DELAY RELAY; UV- UNDERVOLTAGE RELAY; M -MOTOR CONTACTOR; NORMALLY OPEN NORMALLY CLOSED TIME CLOCK POWER SUPPLY SYMBOL PLAN DIAGRAM I I I I 101 CB 11 04 1 -25 -1 0 $M r�1 - + ffi PB ME HH -1 MH MH -1 I{sIP L b ST 9) 130/3 O 71000/3 b(1R1) 1100/3 6 ST 480V 120V -�▪ �3 '1E111 30 —11 SYMBOLS LEGEND - POWER UNDERFLOOR DUCT METER DESCRIPTION SYMBOL COMBINATION STARTER HP RATED, 3 -POLE, NEMA SIZE 1 MINIMUM UNLESS NOTED OTHERWISE - OVERCURRENT PROTECTION SIZED BY EQUIPMENT MANUFACTURER OR AS NOTED STARTER 3 -POLE, NEMA SIZE 1 MINIMUM UNLESS NOTED OTHERWISE DISCONNECT SWITCH 3 -POLE UNLESS NOTED OTHERWISE - OVERCURRENT PROTECTION SIZED BY EQUIPMENT MANUFACTURER OR AS NOTED CIRCUIT BREAKER NUMBER INDICATES TRIP SEIIING AND NUMBER OF POLES CL - INDICATES CURRENT LIMITING ST - INDICATES SHUNT TRIP TRANSFORMER POLE- MOUNTED TRANSFORMER SUBSCRIPT NUMBERS INDICATE: FIRST NUMBER - NUMBER OF TRANSFORMERS SECOND NUMBER - TRANSFORMER kVA RATING THIRD NUMBER - NUMBER OF PHASES PAD MOUNT TRANSFORMER DELTA WYE OPEN DELTA GENERATOR MOTOR CONNECTION - SEE SCHEDULE FOR MOTOR DATA MANUAL MOTOR STARTER 480Y/277V, 30, 4 -WIRE SURFACE MOUNTED PANELBOARD 208Y/120V, 30, 4 -WIRE, SURFACE MOUNTED PANELBOARD 208Y/120V 30, 4 -WIRE, RECESS WALL MOUNTED PANELBOARD EQUIPMENT CABINET - SURFACE MOUNT, TYPE AS NOTED BATTERY EQUIPMENT CONNECTION POWER POLE PULLBOX HANDHOLE WITH DESIGNATION MANHOLE WITH DESIGNATION PUSHBUTTON P INDICATES WITH PILOT LIGHT EQUIPMENT EMERGENCY POWER OFF (EPO) ,SWITCH MICROPROCESSOR CONTROLLED MONITOR REFER TO SPECIFICATIONS FOR METERING VALUES AND PROTECTIVE FUNCTIONS . CURRENT TRANSFORMER QUANTITY AND RATIO AS INDICATED BREAKER WITH EXTERNAL GROUND FAULT RELAY AND CT CIRCUIT BREAKER WITH GROUND FAULT PROTECTION NUMBER INDICATES TRIP SETTING AND NUMBER OF POLES MOTOR - OPERATED CIRCUIT BREAKER PLAN J.DIAGRAM sv 0 14 �WP SYMBOLS LEGEND - POWER DESCRIPTION —L_ -0 CT- -0 1 0- AS 1 NUMBER INDICATES TRIP SEIIING AND NUMBER OF POLES PLAN DIAGRA SWITCH WITH EXTERNAL GROUND FAULT RELAY AND CT POTENTIAL TRANSFORMER QUANTITY AND VOLTAGE RATING AS INDICATED SURGE ARRESTORS FUSE WITH RATING MOTOR THERMAL OVERLOADS - (3) UNLESS OTHERWISE NOTED 2- POSITION SELECTOR SWITCH 3- POSITION SELECTOR SWITCH HAND -OFF- AUTOMATIC ON -OFF SELECTOR SWITCH 2- CIRCUIT PUSHBUTTON PUSHBUTTON SWITCH MOMENTARY CONTACT SYMBOLS LEGEND - COMMUNICATION SYMBOL CIRCUIT CLOSING CIRCUIT OPENING HIGH VOLTAGE CABLE TERMINATOR SEPARABLE CONNECTOR DRAWOUT AC TYPE POWER CIRCUIT BREAKER AIR TERMINATOR LIGHTNING ARRESTORS NEUTRAL GROUNDING RESISTOR INDICATING INSTRUMENT AM- AMMETER; VM- VOLTMETER; FM- FREQUENCY METER; kVAR - KILOVAR METER; kWH- KILOWATT HOUR METER; kVAR /D- KILOWATT HOUR DEMAND METER INSTRUMENT SWITCH AS- AMMETER SWITCH; VS- VOLTMETER SWITCH; SS- SYNCHRONIZING SWITCH; SV- SUPERVISORY (LOCAL - REMOTE) SWITCH MOV SURGE PROTECTION RESISTOR SOLENOID VALVE MOTOR- OPERATED VALVE THERMOSTAT TERMINAL BLOCK - NUMBER INDICATES REFERENCE RECEPTACLE OUTLET: SUBSCRIPT NUMBER INDICATES CIRCUIT GROUPING SUBSCRIPT LETTER INDICATES: XP EXPLOSION PROOF GFI GROUND FAULT CIRCUIT INTERRUPTER WP WEATHERPROOF IG ISOLATED GROUND C CEILING MOUNTED S SURFACE MOUNTED GROUNDING -TYPE SINGLE RECEPTACLE GROUNDING -TYPE DUPLEX RECEPTACLE GROUNDING -TYPE DOUBLE DUPLEX RECEPTACLE SPLIT -WIRED GROUNDING -TYPE DUPLEX RECEPTACLE SPECIAL PURPOSE RECEPTACLE - TYPE AS NOTED FLUSH FLOOR BOX WITH HINGED DEVICE COVER FLUSH FLOOR BOX WITH DEVICES AS NOTED PEDESTAL - MOUNTED DEVICES ON FLOOR BOX OR FLOOR DUCT FLUSH FLOOR COUPLING WITH RECEPTACLE FLUSH FLOOR COUPLING WITH SINGLE PEDESTAL RECEPTACLE b 0 0 CH 4 04P W '1> D DESCRIPTION ICM ICR MICROPHONE OUTLET SPEAKER: S- SECURITY, F -FIRE ALARM LOWER -CASE LEI IER INDICATES SWITCHING GROUP SPEAKER - CEILING SURFACE - MOUNTED SPEAKER - CEILING RECESS - MOUNTED SPEAKER - WALL SURFACE - MOUNTED SPEAKER - WALL RECESS - MOUNTED AUXILIARY INPUT JACK VOLUME CONTROL AUDIO /VIDEO SYSTEM JACK COMPUTER /DATA OUTLET FLUSH FLOOR COUPLING WITH PEDESTAL TELEPHONE OUTLET COMBINATION VOICE /DATA OUTLET SUBSCRIPTS INDICATE: A - COMPLIES WITH A.D.A. D - DESK - MOUNTED P - PAY PHONE W - WALL - MOUNTED INTERCOM STATION - SUBSCRIPT INDICATES: D - DESK - MOUNTED STATION OUTLET M - MASTER STATION W - WALL- MOUNTED OUTLET INTERCOM SWITCH TELEPHONE OUTLET - SUBSCRIPT INDICATES: A - COMPLIES WITH A.D.A. D - DESK - MOUNTED P - PAY PHONE W - WALL - MOUNTED TELEVISION OUTLET CLOCK - WALL - MOUNTED CLOCK - CEILING - MOUNTED, DOUBLE -FACED CLOCK AND SPEAKER COMBINATION INTERCOM MASTER STATION INTERCOM REMOTE STATION ANNUNCIATOR - TYPE AS NOTED SYMBOLS LEGEND - FIRE ALARM SYMBOL PLAN DIAGRA DESCRIPTION SYMBOLS LEGEND - SECURITY DESCRIPTION CCTV CAMERA FIXED WP INDICATES WEATHER PROOF CCTV CAMERA - PAN, TILT, ZOOM SECURITY SYSTEM MOTION SENSOR SECURITY SYSTEM DOOR /WINDOW CONTACT ACCESS CONTROL KEYPAD ACCESS CONTROL CARD READER ACCESS CONTROL REQUEST TO EXIT SECURITY SYSTEM DOOR LOCK '0 0 110 o, 110 n 4C TCP t IFSDI 0 TC 0 0 .,po, n 0 v F 0 FIRE ALARM HORN STROBE COMBINATION - WALL MOUNTED SUBSCRIPT INDICATES STROBE CANDELA. ADJACENT LETTER "C" DENOTED CEILING MOUNTED. FIRE ALARM SPRINKLER BELL FIRE ALARM MINI -HORN - WALL MOUNTED FIRE ALARM STROBE - WALL MOUNTED SUBSCRIPT INDICATES STROBE CANDELA FIRE ALARM BELL STROBE COMBINATION -WALL MOUNTED SUBSCRIPT INDICATES STROBE CANDELA FIRE ALARM PULL STATION FIRE ALARM SYSTEM CONTROL PANEL ESR - ELEVATOR STATUS /RECALL FAC - FIRE ALARM COMMUNICATOR FCP - FIRE ALARM CONTROL PANEL FSA - FIRE SYSTEM ANNUNCIATOR HCP - HALON CONTROL PANEL HVA - HVAC OR EXHAUST STAIRWELL PRESSURIZATION FIRE ALARM ANNUNCIATOR FIRE ALARM RELAY FIRE FIGHTER PHONE JACK FIRE ALARM SPRINKLER TAMPER SWITCH FIRE ALARM SPRINKLER FLOW SWITCH FIRE ALARM SPRINKLER SUPERVISORY SWITCH FIRE ALARM SPRINKLER LOW PRESSURE SWITCH FIRE ALARM DUCT SMOKE DETECTOR - WITH TUBE FIRE ALARM SMOKE DETECTOR - CEILING MOUNTED FLAME DETECTOR FIRE ALARM .CHIME FIRE ALARM HEAT DETECTOR - CEILING MOUNTED ALARM BUZZER A- ALARM; F -FIRE; S- SECURITY FIRE /SMOKE DAMPER GAS DETECTOR FIRE ALARM TERMINAL CABINET PROJECT GENERAL NOTES: 1. SYMBOLS SHOWN IN THE LEGEND ARE TYPICAL. NOT ALL SYMBOLS MAY APPLY TO THIS PROJECT. 2. PROVIDE ALL MATERIALS, LABOR AND EQUIPMENT REQUIRED FOR A COMPLETE AND OPERATIONAL INSTALLATION. MATERIALS AND WORKMANSHIP SHALL FULLY COMPLY WITH THE REQUIREMENTS OF THE LATEST EDITION OF THE NATIONAL ELECTRICAL CODE, THE INTERNATIONAL BUILDING CODE, AND THE LAWS AND REGULATIONS OF THE STATE OF WASHINGTON. OWNER: 0 Lem C H 0 N N v- ONSULTANT: WA 98168 -5121 0 co 0 - E 0 Lo O ti 0) U O rn • N N 0 0 .0 N N N CO CO 0 0 N N I-IU. 3 fLUW9Q 1 REVIEWED FOR COMPLIANCE WITH NFPA70 -NEC FEB 17 2011 City of Tukwila BUILDING DIVISION RECEIVED FEB 0 4 2011 PERMITCENTER C/) 0 U H U) w w 1- 0 ca Z TM 603376 w O op Q (0 0.1 00 J 0 CV CO 0 N N 0 N F- 0 w 0 a ISSUED / REVISED DATE PROGRESS DRAWING 4/29/10 REVIEW SET 1/14/11 PERMIT SET 1/28/11 PHASE 42 LEGEND E0.01 3 A 1 2 3 5 6 7 8 9 10 LIST OF ABBREVIATIONS ABBREVIATION DESCRIPTION ABBREVIATION DESCRIPTION ABBREVIATION DESCRIPTION A AMMETER, AMPERE OR AMPS GA GAUGE PREFAB PREFABRICATED ABND ABANDON GALV GALVANIZED PRI PRIMARY ABV ABOVE GEN GENERATOR PS POWER SUPPLY AC ALTERNATING CURRENT GFI GROUND FAULT CIRCUIT INTERRUPTER PT POTENTIAL TRANSFORMER AF AMP FRAME GRS GALVANIZED RIGID STEEL PVC POLYVINYL CHLORIDE AFF ABOVE FINISHED FLOOR PWR POWER AFG ABOVE FINISHED GRADE H HEIGHT (HIGH) % PERCENT AHU AIR HANDLING UNIT HH HANDHOLE AIC AMPS INTERRUPTING CURRENT HID HIGH INTERNSITY DISCHARGE QTY QUANTITY AL ALUMINUM HOA HAND - OFF -AUTO APPROX APPROXIAMTELY HORIZ HORIZONTAL R RESISTANCE, RADIUS, REMOTE ARCH ARCHITECTURAL HP HORSEPOWER RECD RECEIVED AT AMP TRIP HPS HIGH PRESSURE SODIUM REC RECEPTACLE ATS AUTOMATIC TRANSFER SWITCH HT HEIGHT RED REDUCER AUTO AUTOMATIC HTR HEATER REF REFERENCE AUX AUXILIARY HV HIGH VOLTAGE REQD REQUIRED AWG AMERICAN WIRE GAGE REV REVISION CURRENT RPM REVOLUTIONS PER MINUTE BATT BATTERY IBE INSTALLED /CONNECTED BY ELECTRICAL RM ROOM BC BOLT CIRCLE, BARE COPPER IBO INSTALLED BY OTHERS RS RAPID START BIL BASIC IMPLUSE LEVEL IC INTERRUPTING CAPACITY RTU REMOTE TERMINAL UNIT BKR BREAKER ICS ILLUMINATION CONTROL STATON RVAT REDUCED VOLTAGE AUTOTRNASFORMER BLDG BUILDING ID INSIDE DIAMETER RVNR REDUCED VOLTAGE NON - REVERSING BOT BOTTOM IDF INTERMEDIATE DISTRIBUTION FRAME BTWN BETWEEN IJB INSTRUMENT JUNCTION BOX S SOUTH INCL INCLUDING SCADA SUPERVISORY CONTROL AND C CONDUCTOR, CONDUIT OR CENTIGRADE IN INCH OR INCHES DATA ACQUISITION CAB CABINET INST INSTANTANEOUS SCHED SCHEDULE CAT CATALOG INSTR INSTRUMENT SEC SECONDARY OR SECOND CB CIRCUIT BREAKER SECT SECTION CKT CIRCUIT J, JB, J -BOX JUNCTION BOX SF SUPPLY FAN CLG CEILING SHLD SHIELD OR SHIELDED CO CONDUIT ONLY WITH PULL STRING k THOUSAND SHT SHEET COL COLUMN kcmil THOUSAND CIRCULAR MILS SK SKETCH COMM COMMUNICATIONS kV KILOVOLT SIM SIMILAR CONC CONCRETE kVA KILOVOLT AMPERES SPDT SINGLE -POLE DOUBLE -THROW COND CONDUIT kVAR KILOVOLT AMPERES REACTIVE SPEC SPECIFICATION(S) CONN CONNECT /CONNECTION kVARH KILOVARHOUR SQ SQUARE CONSTR CONSTRUCTION kW KILOWATT SS STAINLESS STEEL CONT CONTINUOUS kWH KILOWATT HOURS ST SHUNT TRIP OR STREET CONTR CONTRACTOR .. kWHD. KILOWATT- HOUR DEMAND STD STANDARD COORD COORDINATE STL STEEL OP CONTROL PANEL L LENGTH, LOCAL STRUCT STRUCTURAL ._ CPT CONTROL POWER TRANSFORMER LCP LIGHTING CONTROL PANEL SUB ' SUBSTITUTE CR CONTROL RELAY LED LIGHT EMITTING DIODE SUBSTA SUBSTATION CS ° CONTROL STATION LF LINEAR FOOT /FEET SUPT SUPPORT CT CURRENT TRANSFORMER LS LIMIT SWITCH SV SOLENOID VALVE CTR CENTER LT LIGHT SVC SERVICE . CTRL CONTROL '= LTG LIGHTING SW SWITCH CU COPPER LTS LIGHTS SWBD SWITCHBOARD LV LOW VOLTAGE SWGR SWITCHGEAR DC DIRECT CURRENT L -L LINE -TO -LINE SYM SYMMETRICAL DED DEDICATED' SYNC SYNCHRONOUS DET DETAIL M OR MTR MOTOR . SYNSC SYNCHROSCOPE DIA DIAMETER MATL MATERIAL SYS SYSTEM DIM DIMENSION MAX MAXIMUM DISC DISCONNECT MCA MINIMUM CIRCUIT AMPACITY T THERMOSTAT DISTR DISTRIBUTION - MC METAL CLAD CABLE TB - TERMINAL BLOCK DN DOWN - MCC MOTOR CONTROL CENTER TBD TO BE DETERMINED DP DISTRIBUTION PANELBOARD MDF MAIN DISTRIBUTION FRAME TD TIME DELAY DWG DRAWING MECH MECHANICAL TEL TELEPHONE MFR MANUFACTURER TEMP TEMPERATURE OR TEMPORARY SYSTEM SUMMARY Sabey DataCenter 42 (SDC 42) will be a new wholesale colocation facility located within International Gateway East, Building 5, also known as SDC 5. Conceptually, it will have approximately 30,000 square feet of IT equipment space on the 2nd floor, supporting an ultimate 4.5 MW of IT Toad. This will be a hybrid design with approximately 1500 kW of non - mission critical (lab) data center space load and approximately 3000 kW of mission critical (production) load. The non - mission critical load will have non - redundant UPS, but no generator. There will be some mechanical redundancy, relying on the mission critical HVAC plant. Environmental conditions will be managed, but not guaranteed. The facility central plant will be built in three phases. Phase 1 will support 1.425MW of lab capacity and 1.425MW of production capacity, Phase 2 will support a total of 1.425MW of lab capacity and 2.85MW of production capacity. The mechanical system will be sized for the full 4.5MW of capacity by Phase 2, and additional UPS can be installed in the future to bring the space up to the 4.5MW. System design redundancy objective is concurrently maintainable (similar to Uptime Institute, Tier 3) for the production space and non - redundant for the lab space. X1,11- 00120, REVIEWED FOR COMPLIANCE WITH NFPA70 -NEC FEB 17 2011 City of Tukwila BUILDING DIVISION RECEIVED FEB 0 4 2011 PERMIT CENTER w z co tt F- tl N N CONSULTANT 1 O 0 LL O O O co O 0) CA E O U >▪ , N CO CO Q N N Cp CD CD O O ?� N Us TM 603376 PROJECT #210252.06 ISSUED / REVISED DATE PROGRESS DRAWING 4/29/10 REVIEW SET 1/14/11 PERMIT SET 1/28/11 PHASE 42 ABBREVIATIONS & SYSTEM SUMMARY E0.02 F E D c B A 1 2 3 4 5 7 8 9 ELECTRIC & COMMUNICATIONS 1131/2011 13:48 Pretask Planning Designation Raceway Wire Permanent Circuit/CB Temporary Feeder Circuit/CB Length Number Number Supplier Weight Lead Wks Release Date Sections Ship Delivery Vertical Horizontal Dimensions Install Date Date Method Method Date Room Model No. Serial Number Manufacturer VECA Complete Startup Startup 1/28/2011 Vendor Comm. Begins Complete Confirmed Date 26kV Switches HVS -42A (2) 6' PVC SCH 40 35kV (3) 350kCMIL 2/0 ORNO MSG F1 /F2 N/A 16 2 Nelson Trucking to Set SDC 42 Gen 26kV Switches HVS -42B 26kV Switches 3000kVA Transformer (2) 8' GRC 35kV (3) 350kCMIL 2/0 GRND MSG F1 /F2 N/A 16 HVS -42C (2) 6• GRC HVS -42A Factory Buss 3000kVA Transformer HVS -428 Factory Buss 35kV (3) 350kCMIL 2/0 GRND Factory Buss Factory Buss MSG F1 /F2 N/A 16 16 2 Nelson Trucking to Set SDC 42 Gen 2 1 Nelson Trucking to Set Nelson Trucking to Set 16 3000kVA Transformer Unit Sub Section HVS -42C Fairy Buss HVS -42A Factory Buss Factory Buss Factory Buss 16 16 1 Nelson Trucking to Sel SDC 42 Gen SDC 42 Gen SDC 42 Gen 1 Nelson Trucking to Set Nelson Trucking to Set SDC 42 Gen SDC 42 Gen Unit Sub Section HVS-42B Factory Buse Factory Buss Unit Sub Section Transfer Switch HVS -42C Transfer -42A Factory Buse --_-_-_- Factory Bun - Factory Buse Factory Buse Transfer Switch Transfer Switch Transfer -42B Transfer -42C Factory Buss Factory Buse Factory Buse Factory Buss 16 16 Nelson Trucking to Set SDC 42 Gen 10 Nelson Trucking to Set Nelson Trucking to Set 10 Nelson Trucking to Set SDC 42 Gen SDC 42 Gen SDC 42 Gen 10 Load Bank SWBD LB-42B Load Bank SWBD LB-42C Nelson Trucking to Set Nelson Trucking to Set Nelson Trucking to Set SDC 42 Gen SDC 42 Gen SDC 42 Gen Dist. Switchboard Dist. Switchboard HDP -42A (10) 3 -112 EMT HDP -42B (10) 3-1/2 EMT (3) 600kCMIL 500kCMIL GRND (3) 600kCMIL 500kCMIL GRND 10 6 10 6 Nelson Trucking to Set Nelson Trucking to Set SDC 42 UPS SDC 42 UPS Dist. Switchboard HDP -42C (10) 3-112 EMT (3) 800kCMIL 500kCMIL GRND 10 6 Nelson Trucking to Set SDC 42 UPS Dist. Switchboard HDP -42D (10) 3-112 EMT (3) 800kCMIL 500kCMIL GRND 10 6 Nelson Trucking to Set SDC 42 UPS Branch HV XFMR XFMR- 42A -H1 Branch HV XFMR Branch HV XFMR XFMR - 428 -H1 XFMR- 42C-H1 (1) 1 -114• EMT (1) 1 -1/4' EMT (1) 1 -114• EMT Branch LV XFMR XFMR- 42A -L1 (1) 3/4• EMT (3) #4b & 48 GRND (3) #4Y & 48 GRND (3) #4's & #8 GRND HDP-42A -CB #14 HDP42B -CB #14 HDP42C-CB #14 N/A N/A 5 5 5 (3) #8k & #10 GRND HOP-42A-CB 015 N/A Branch LV XFMR Branch LV XFMR XFMR- 42B -L1 XFMR- 42C -L1 (1) 3/4_EMT (1) 3/4" EMT (3) #8s & #10 GRND (3)#8's &#10 GRND Branch LV XFMR Branch Panel HV XFMR- 428D2 -L 1 PNL- 42A -H1 (1) 1 -114" EMT (3) #2s & 48 GRND (3) #4's & 48 GRND HDP42B -CB #15 N/A HDP42C -CB 415 N/A STS-4213D2 See XFMR CB # 5 5 5 Forklift and Prefab Forklift and Prefab Forklift and Prefab SDC 42 UPS SDC 42 UPS SDC 42 UPS Forklift and Prefab SDC 42 UPS Forklift and Prefab Forklift and Prefab TBD N/A Branch Panel HV PNL- 42B -H1 (1) 1 -114• EMT Branch Panel HV ` PNL- 42C -H1 Branch Panel LV PNL- 42A -L1 Branch Panel LV PNL-42B-L1 (111 -114' EMT (1)1.1/4" EMT (1)1.1/4' EMT Branch Panel LV Branch Panel LV UPS UPS PNL- 42C -L1 PNL- 42BD2 -L1 UPS -42A1 UPS-42A2 (1) 1 -1/4" EMT (1)2.12" EMT (3) 3-112' EMT (3) 3.117 EMT (3) 44'a & 48 GRND (3) 44,s & 48 GRND (4) #2's & 48 GRND (4) #2's & 48 GRND (4) #2's & #8 GRND (4) 4/0's & 44 GRND (3) 600kCMIL 3I0kCMIL GRND (3) 000kCMIL 3N0kCMIL GRND See XFMR CB# See XFMR CB# See XFMR CB # Bee XFMR CB # See XFMR CB # ST342BD2 N/A N/A N/A N/A N/A TBD HOP424-CB #1 N/A HOP42A-CB#4 N/A UPS UPS -42B1 (3) 3.12" EMT (3) 600kCMIL 3IOkCMIL GRND HDP4213-CB #1 N/A UPS UPS UPS UPS -42B2 UPS-42C1 (3) 3,1 /7 EMT (3) 3-12• EMT (3) 600kCMIL 3/13kCMIL GRND (3) 8000CMIL 3/0kCMIL GRND HDP420-CB#4 HDP42C -CB #1 N/A N/A 5 6 6 6 6 6 6 Forklift and Prefab Forklift and Prefab Forklift and Prefab Forklift and Prefab Forklift and Prefab Forklift and Prefab SDC 42 UPS SDC 42 UPS SDC 42 UPS SDC 42 UPS SDC 42 UPS • SDC 42 UPS SDC 42 UPS SDC 42 UPS Forklift and Prefab Forklift and Prefab SDC 42 UPS SDC 42 UPS 8 7 8 7 8 7 8 7 8 UPS -42C2 (3)3.12 ' EMT (3).800kCMIL 3/OkCMIL GRND HDP42C -CB #4. N/A 8 7 7 Nelson Trucking to Set Nelson Trucking to Set Nelson Trucking to Set Nelson Trucking to Set Nelson Trucking to Set Nelson Trucking to Set SDC 42 UPS SDC 42 UPS SDC 42 UPS SDC 42 UPS SDC 42 UPS SDC 42 UPS • MBP MBP MBP mm MBP MBP MBP -42 -A1 MBP -42 -A2 MBP -42 -B1 MBP -42 -B2 MBP -42 -C1 (3) 3.12• err (3) 800kCMIL 3lokCMIL GRND HDP42A -CB #3 N/A 10 Nelson Trucking to Set SDC 42 UPS (3) 3 -12' EMT (3) 3.112AEMT (3) 3.12• EMT (3) 3.112' EMT (3) 800kCMIL 3I0kCMIL GRND (3) 600kCMIL 3IOkCMIL ORND (3) 600kCMIL 3I0kCMIL GRND (3) 800kCMIL 3IOkCMIL GRND • HDP42A-CB 48 HDP4213-CB 43 HOP42B -CB 66 HOP-QC-CS 63 MBP STS MBP -42 -C2 STS- 42 -BC1 (3) 3-12• EMT (2) 3.12• EMT (3) 1300kCMIL 3/OkCMIL GRND (3) BOOkCMIL 1/OkCMIL GRND STS STS STS-42 -BD1 STS -42 -BC2 (2) 3-12' EMT (2) 3 -12' EMT (3) 800kCMIL 1/OkCMIL GRND (3) 600kCMIL 1 /OkCMIL GRND HDP42C -CB 68 MBP-42-131-CB 41 N/A N/A N/A N/A N/A N/A 10 10 10 10 Nelson Trucking to Set Nelson Trucking to Set Nelson Trucking to Set SDC 42 UPS SDC 42 UPS SDC 42 UPS MBP-42-131-CB #3 MBP42- B2 -CB 61 N/A N/A 10 Nelson Trucking to Set Nelson Trucking to Set 10 10 10 STS STS- 42 -BD2 (2) 3 -1/7 EMT (3) 800kCMIL 1/OkCMIL GRND STS STS STS -42 -CBI STS- 42 -CD1 STS STS PDC 42 -01 PDC 42 -01 PDC 42 -01 PDC 42 -01 STS -42 -CB2 STS- 42 -CD2 (2)3.12" EMT (2) 3.12• EMT (3) 600kCMIL 1(00CMIL GRND (3) 600kCMIL 1/OkCMIL GRND MBP42 -62 -CB 43 N/A 10 Nelson Trucking to Set Nelson Trucking to Set Nelson Trucking to Set SDC 42 UPS SDC 42 UPS SDC 42 UPS SDC 42 UPS SDC 42 UPS Nelson Trucking to Set SDC 42 UPS MBP-42-C1-CB #1 MBP-42-C1-CB 43 N/A N/A r 10 10 (2) 3 -12• EMT (2) 3.1/7 EMT (3) 800kCMIL 1/OkCMIL GRND (3) 600kCMIL 1IO1tCMIL GRND MBP-42-02-CB 41 MBP-42-C2-CB 63 N/A N/A 10 Nelson Trucking to Set Nelson Trucking to Set SDC 42 UPS SDC 42 UPS 10 Nelson Trucking to Set Nelson Trucking to Set SDC 42 UPS SDC 42 UPS PDC- 42A1.i PDC42Al2 PDC-42A1.3 • PDC42A1.4 (1) 3" EMT (1) 3' EMT (1)3• EMT (1) 3• EMT (3) 500kCMIL #2AWG GRND (3) 500kCMIL #2AWG GRND (3) 500kCMIL #2AWG GRND (3) 500kCMIL #2AWG GRND MBP42 -A1 CB#1 MBP-42-A1 CB 42 MBP-42-A1 CB 43 MBP-42-A1 CB #4 N/A N/A N/A N/A 8 2 8 2 8 2 Nelson Trucking to Set Nelson Trucking to Set Nelson Trucldng to Set 42-01 42-01 42-01 8 2 Nelson Trucking to Set 42-01 PDC 42-01 PDC42A1.5 (1) 3• EMT:. (3) 500kCMIL #2AWG GRND MBP-42-A1 CB #5. N/A 8 2 Nelson Trucking to Set 42-01 PDC 42 -01 PDC- 42A2.1 (1)3• EMT (3) 500kCMIL #2AWG GRND MBP-42-A2 CB #1 N/A PDC 42 -01 PDC 42-01 PDC- 42A2.2 PDC- 42A2.3 PDC 42 -01 PDC-42A2.4 EMT (1)3 "EMT (3) 600kCMIL #2AWG GRND (3) 500kCMIL #2AWG GRND MBP-42A2 CB #2 MBP-42-A2 CB #3 N/A N/A 8 2 Nelson Trucking to Set 42-01 8 (1) 3' EMT (3) 600kCMIL #2AWG GRND MBP-42-A2 CB #4 N/A 8' 2 2 Nelson Trucking to Set Nelson Trucking to Set 42-01 42-01 2 PDC 42 -01 PDC -42 -02 PDC-42A2.5 (1) 3" EMT • (3) 500kCMIL #2AWG GRND MBP-42-A2 CB 45 N/A a 8 PDC42-BC1.1 (1) 3" EMT (3) 5000CMIL #2AWG GRND PDC -42 -02 PDC -42 -02 PDC42-BC1.2 PDC42-BC1.3 (1) 3• EMT (1)3 "EMT (3) 500kCMIL #2AWG GRND (3) 500kCMIL #2AWG GRND STS424BC1 CB 41 N/A 8 2 Nelson Trucldng to Set STS42.13C1 CBO2 STS42-BC1 CB63 N/A N/A 8 8 PDC- 42- 02-_^--^_ PDC-42-02 PDC- 42- BC2.1` PDC- 42 -BC22 (1) 3 EMT _- (1) 3• EMT (3) 500kCMIL #2AWG GRND �._ 87342 •BC2 CB #1 (3) 500kCMIL #2AWG 00140 STS-42.13C2 CB #2 N/A i N/A 2 Nelson Trucking to Set Nelson Trucking to Set 42-01 42-02 Nelson Trucking to Set Nelson Trucking to Set 42-02 42-02 PDC-42-02 PDC- 42 -BC2.3 (1) 3•EMT (3) 500kCMIL #2AWG GRND STS42-BC2 CB 63 N/A PDC -42 -02 PDC- 42 -CB1.1 (1) 3• EMT PDC -42 -02 . . PDC-42 -CB1.2 (3) 500kCMIL #2AWG GRND STS42-CB1 CB#1 8 2 2 Nelson Trucking to Set Nelson Trucking to Set 42-02 42-02 2 �.- .._ -.�.. _---- _-- '. ---_,. N/A Nelson Trucking to Set 42-02 Nelson Tnicidng to Set 42-02 (1) 3" EMT (3) 500kCMIL #2AWG GRND STS42- CB108#2 N/A PDC -42 -02 PDC- 42 -CB1.3 PDC,42-02 PDC-42-C62.1 (1) 3• EMT (3) 500kCMIL #2AWG GRND S1S42 -C81 CB#3 N/A 2 Nelson Trucking to Set 42-02 (1) 3• EMT .: (3) 500kCMIL #2AWG GRND STS•2 -CB2 CB 61 N/A 8 2 2 Nelson Trucldng to Set Nelson Trucking to Set PDC -42 -02 PDC -42 -02 PDC -42 -02 PDC-42 -CB2.2 PDC- 42 -CB2.3 PDC- 42 -CD1.1 (1) 3.. EMT. • (1) 3' EMT (3) 500kCMIL 42AWG GRND. • (3) 500kCMIL #2AWG GRND STS42-CB2 CB 62 STS-42-CB2 CB #3 N/A N/A 8 2 2 Nelson Trucking to Set Nelson Trucking to Set (1) 3' EMT... (3) 500kCMIL #2AWG GRND STS.42 -col 0861 N/A 2 42-02 42-02 42-02 42-02 Nelson Trucking to Set PDC-42-02 PDC- 42 -CD1.2 (1) 3' EMT (3) 500kCMIL #2AWG GRND STS42-CD1 CBII2 NIA 8 PDC -42 -02 PDC-42-C21.3 (1) 3' EMT, (3) 500kCMIL #2AWG GRND STS-42-001 08#3 N/A 8 2 Nelson Trucldng to Set 42-02 42-02 2 Nelson Trucking to Set PDC -42 -02 PDC -42 -02 PDC- 42 -DC1.1 PDC42-DC1.2 (1) 3• EMT (3) 500kCMIL #2AW0 GRND. STS-42-13C1 CB#1 N/A 8 2 Nelson Trucking to Set 42-02 (1)3 "EMT (3) 500kCMIL #2AWG GRND STS- 42 -DC1 CB #2 N/A 8 2 Nelson Trucking to Set 42-02 PDC -42 -02 - - PDC- 42 -DC1.3 (1) 3" EMT. (3) 500kCMIL #2AWG GRND. STS- 42 -DC1 CB#3 N/A Nelson Trucking to Set 42-02 ELit liZ REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC FEB 1 7 2011 City of Tukwila -- BUILDING DIVISION RECEIVED FEB 04 2011 PERMIT CENTER tit et VI CO IZ co CL CD CNI CONSULTANT kii!) 109' 411111-2- 00 0 0 LL 0 co 0 co co CL CD op 00 00 CO co u. 0 0 TM 603376 NTERGATE EAST CAMPUS 0 co co co co cti CO 0 ISSUED / REVISED DATE PROGRESS DRAWING 4/29/10 REVIEW SET 1/14/11 PERMIT SET 1/28/11 PHASE 42 PRETASK PLANNING E0.03 B A 1 2 3 4 5 6 7 8 9 10 - 10 — — — 11 — — — 12 - 13 - — — 14 I 41 10 11 — 11 • "WINE =MO r 11 10 11 0 10 10 Lr cs :I A 0 DAY fJ TANK CNTRLSil I DAY TANK 42D evonsmemMIR.s.MN 11 -,1110,1 .1111,110 .11111,;: TAs ;11 111.7, „4 IsOorK, ,41‘411ti GEN INPUT FROM' 13 — 13 Lij NORMAL INPUT •FRONT` m SUBSTATION HV SWITCH HV SWITCH waxview*D.vavasveavacescexamo.vaxaeavwxv..v.wavaveonavivaricsavaxacv. TRANSFORMER 3000 KVA HVS-42A BACK BACK DAY TANK 42B —74 BACK TRANSFORMER 3000 KVA HVS-42D 1 f Ii; .... t t. 1 FFICSIT .... SUBSTATION TRANSFORMER 3000 KVA HVS-42C 11 ELM HV SWITCH HV SWITCH HV SWITCH HV SWITCH 10 10 12 13 0 HVS-4:213 TRANSFORMER 3000 KVA SUBSTATION 0 FROM 14 14 — 14 0 LEVEL 1 OVERALL PLAN 1/8"•-o• 14 u- 0 MECHANICAL EQUIPMENT AREA BATTERY MONITOR PAWL PNLM4.4 C•1 XFRATO PNL 4.213-Ht %FR-Mini PNL425-0\11 1 L w 13 14 13 — 14 14 — 0 REVIEWED FOH COMPLIANCE WITH NFPA 70 - NEC FEB 1 7 2011 City of Tukwila BUILDING DIVISION RECEIVED FEB 04 2011 PERMIT CENTER w z ONSULTANT 1- 0 w w W w < < (c) • ° oo 4 1— I (I) < o. c) WCN N W CU - • .— O < ° V) w I— I— TM 603376 ISSUED / REVISED DATE PROGRESS DRAWING 4/29/10 REVIEW SET 1/14/11 PERMIT SET 1/28/11 PHASE 42 LEVEL 1 OVERALL PLAN E1.10 1 2 3 4 5 6 7 8 9 1 0 E F — G — INX.V E E — t1 1 NORMAL INPUT SECTION / SECTION, 2 SECTION. Si SEC.TION..4% : \ : SECTION .5% \ SECTION 6 M , > 0 > 1\ r- m 0 NORMAL INPUT • k SECTION SECTION, i• • SECTION . . SECTION SECTION. 'SWITCHBOARD HDP742C./ , „-/ FUTUR /./ • • / • % FUTUR .... • • • .. 250KVA/UPS DIST (8) 800A MS UBC75 CABLE ENTRY FI5OICVAIUPS DIST (8) 800A CABL ENTRY • ▪ \ / \ "-a 1 1 1 1 / \ / •%. .„,.,..., ..., ,. ...., ,,,,....-/ ...., ..........^... .....,'"'"`- .., ..., /- \ / N. / N. 1 1 1/ / / 1 4 1 ‘, / 0 ,...• ...- .... ..... -.... „,....- • -.......... .... ,.... m -, ...., ,.. 11110111111111 750KVNUPS CABLE NTRY MBS UB875 DIST (8) 800A 750KVA/UPS CABLE NTRY MBS UB875 DIST (8) 800A BAT 1 BAT BAT 3 BAT 4 F F F F N F• F 03 F F BAT 2 DIST (8) 800A MS UBC75 m z r- m c "o m z m CABL ENTRY DIST (8) 800A \ \.... , . „ . . . . . . . „ „ \ \ . ernuollmmi.lmilmAMM11.11041NIMIMMIM BR7,42-B BP \ . . . ..„ .„.. \s„ \ 750KVAIUPS CABLE NTRY MBS UB875 DIST (8) 800A CABLE DIST (8) 800A BAT 3 250It*UPS •. \ \ , ,. • •• , \ • \.„ \ w SECTION S' SECTION :SECTION A! KSECTION SECTION a?: . . , SECTION 41 . , . „ SECTION :. SECTION2 --. SECTION \ / NORMAL INPUT \ \ •••••,.. LEVEL 1 UPS ROOM LAYOUT 1/4".1.-0” 0 „ E F — G — F G — REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC FEB 1 7 2011 City of Tukwila BUILDING DIVISION RECEIVED FEB 04 2011 PERMIT CENTER w z ONSULTANT C co CO co 0) 1 0 0 4- LL .a 0 U_ co co (Ni c\I LO 0) 0) CN CO CNI CO 4 0. TM 603376 0 00 CD 00 Cr) ISSUED / REVISED DATE PROGRESS DRAWING 4/29/10 REVIEW SET 1/14/11 PERMIT SET 1/28/11 PHASE 42, LEVEL 1 UPS ROOM LAYOUT E1.11 F E D B A 1 2 3 4 5 6 7 8 9 10 9 10 TO ND#1 11 — 12 13 — 14 — 11 6"C SCH 40 PVC 10 m 111 10 — — 11 — 11 / / / / / / / / / / / / / / / / / / / / / / / / / / PNL-42D—L1 CKT #39,41 BLOCK HEATER 12f4 1 11 .3000 KVA 0 6"C — 3 SINGLE CABLE #350KCMIL, 35KV & 1#2/0 GROUND 12 t3:4K 1 10 11 10 11 0 0 0 3 BATTERY CHARGER PNL-42D—L1 CKT #3 PNL-42C—L1 CKT #39,41 *Tr • BLOCK HEATER N 'TANK DAY I] rpCNTRLS‘,1 1 TRikiciFoRwap: CKT) TiV8.420 0 9 10 11 12 DAY TANK 421) SIA3STAIII)1 I-IV :TWITCH 11V SWITCH 11.1111 11.1 1.1 1.24701. L_. ESTC31:', 1. 1 •, GAY TANK SEINSTATION 10 11 mem,' 42;" 9 - 9 E.: L 9 9 0 0 -10 PNL-42B—L1 CKT #42 HEAT TRACE CONNECTION 10 11 11 ••T .1.1x ... 0 •• • 0 PNL-42D—L1 CKT #1 12 — 9 10 9 10 r :11 — PNL-42A—L1 CKT #1 ... 1' .. ... •••••... 1 1 L. L 3 ..„, PNL-142C—L1 CKT #1 seccecceaccezem, - PNL-42B—L1 CKT 13 BATTERY CHARGER PNL-42C—L1 CKT #3 j. - 1 1 ...1 ... 1 • BLOCK 1 ...( HEATER 1 .... 1 iL 39,41 r. ."1.141_ DAV c3 TANK ' !:•3 I 'TRL #1 VA 59AN114,0:401 :MO K 111/5-42C PN1.01 gC—L1 13 13 13 PNL— 2Bt DAY 1 1 TANK LS1 1 PNL-42B—L1 CKT #15 :: . BATTERY - • .. P 1.1 NORMAL SURTFA•CN iNPUr INPUT TNANeRiPMEP :.T1:10KVi1 Tin,42A D.AY TANK 420 TiVS-426 TRANeFORMER i4V *17,1 NV 47.1 1 1 14 — 14 — P v SWITTli V 91.VITCH 1 —ttj CKT #3 MW MX: — 0 14 — . - • 14 — 14 — 1 0 14 — 13 — 1 14 — R-4AC•tit 13 — 13 LEVEL 1 POWER PLAN I 1/81'.0" - PNL-42A—L1 CKT #5 PNL-42B—L1 CKT #5 PNL-42C—L1 CKT #5 14 — 14 • 14 - 13 .1 PNL-42D—L1 CKT #5 14 — 9 - 12 CKT #1 13 13 COORDINATE FINAL LOCATION WITH COORDINATE FINAL LOCATION WITH 1=.• EXTEND EXISTING STUBS AND EXTE 3 — 9 - 10 12 j. / .D.C. UNBELT CONTROLS D TO HVS-42A STUBOUT AND CAP FOR FUTURE H S HOUSEKEEPING PADS TO EXTEND 41 BEYOND EDGE OF EQUIPMENT 14 — — 14 — iiEVIEVVED FOR COMPLIANCE WITH NFPA 70 - NEC FEB 1 7 2011 City of Tukwila B ILDING DIVISION RECEIVED FEB 04 2011 PERMIT CENT R eI — g V011 o 4 ?Ai • 1 CONSULTANT 0 0 co csJ 0 TM 603376 C/) 0_ 0 0 1— z 0 LO CO co c‘i Lo CN1 0 0 LLI 0 ISSUED / REVISED DATE PROGRESS DRAWING 4/29/10 REVIEW SET 1/14/11 PERMIT SET 1/28/11 PHASE 42, LEVEL 1 POWER PLAN E2.11 F E D B A 2 3 4 5 6 7 8 9 10 9 10 11 — 12 Ea. 411 HDP-42C C.B. I 11 , fl 1_ •• .ij 1 10 11 — 1 r m m RON 9 10 10 11 — 11 — 11 1. a 000 KW, 10 10 — 1/2" C. (3)#12's & #12 GRND 12 — a 9 9 • 0 • 0 a 0 10 — HDP-42C C.B. #40 10 11 12 — 12 DAY TANK 42D TRANSFORMER :3(Kg) KVA • HVS$2t -11)1MAR:F4- „DE: ........ DAY '• TAW. 44TRLS \ 0 13 — 13 \ ........ .• EN 42Ft r!40141. NORMAL iNPUT . ........................................ • c2 1 _J SIBOTARON 'RV:N:31-01.1MB 3MK) KVA VS-42A Hy SWITCH ;TWTCH I 14 \ T4 — DAY TAW 42B 14 — — 0 14 — :-:11 MICH HV SWiTCH F•m,41' FRIti; L.T.T.Tisla...„„.--1-...1 L.. .. I 1 1. . L.. LLE3STATiON 9 — 9 ____ L. 9 9 9 9 PNL-42B—L1 CKT #2 1/2" C. (2)#12's & #12 GRND CP-42B1 CP-42C1 10 — PNL-42C—L1 CKT #2 ,„. -g= A ••• FR.42D4.1 PAW. \ 42I.441 1 CRAC-42C1 1 CRAC-42D1 ■■■■ .■■• •■•■■ .■■■ •■•.• ■•■••• TrWiORMER ::41 KVA L4VE•420 13 HINS.42.S TRANSPORIER !MD KVA 13 13 13 MCRWAS WAWMM z a 14 — 14 — 0 14 — •• •• • • • • • • • • • • • • • • • • •• • • •• • • 7:2Yrit, \ ,40,1ffeN: 9 ... \ 14 — LJ 13 13 13 a1 too 14 — 14 LEVEL 1 MECHANICAL POWER PLAN N. 13 • 0 14 — 14 — • HDP-42B C.B. #38 HDP-42C C.B. #38 10 [1 9 HDP-42D C.B. #38 TEMPORARY FEED HDP-42C C.B. #3 1-1/4" C. (3)#4's & #8 GRND 13 — 10 9 10 • ``""'•-•"--""1-122.'4321 ... T1 12 — 12 — 12 1131 — ••••••.„... COORDINATE FINAL LOCATION WITH .D.C. [Z>. COORDINATE FINAL LOCATION WITH UNBELT CONTROLS — 4 EVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC FEB 1 7 2011 dem""aray Tukwila LDING DIVISI N RECEIVED FEB 04 2011 PERMIT CENTER 14 Fr i tx co v F;11, ONSULTANT ill9 co 0 LU 0 " 0 o iu c° r'' °) 0 cT; 1.- CO c 06 Wd- 0 0 >04-',°. <CO Ea, ir 0 [-- w J Nr • CO • ca a) U) TM 603376 00 v- 00 z 0) 1— ISSUED / REVISED DATE PROGRESS DRAWING 4/29/10 REVIEW SET 1/14/11 PERMIT SET 1/28/11 PHASE 42, LEVEL 1 POWER PLAN E2.11M A 10 8 — 9 — 10 — 8 — 9 — 10 — 8 — 10 — 8 LEGEND m CO 1/2 "C (2) #12 & #12 GRND SHEET NOTES FOR BMS CONTROL POWER ....L.. • • m` 8 10 8 8 9 8 — 8 — 8 — 8 — 8 — 8 — 8 — 8 — 8 8 8 9 7.. 9 PHASE 2 10 "I- 10 — 10 — rt I }II . ... ,..L. a: I I ; I • 9 — PNL-- 42C- "L1..... T 10 — .,. . . . . . . .I .. . . . . . . . . . . .1 1 .........I LEVEL 2 POWER PLAN 118••-1• -0° 9 —1 9 !— 9 — i 1 10 1. 10 �— V 10 9 9 10 1— 10 9 10 — I : ■ :V • d— 9 42A —L1 CKT #9 10 PNL- 42B —L1 CKT #7 1 0 PNL -42A • L1 CKT 7 8 10 8 9 10 NEVI ' WED FOR COMPWANCE WITH NFPA 70 - NEC FE1172011 City of Tukwila BUILDING DIVISION RECEIVED FEB 04 2011 PERMIT CENTER w z 0 a VI m 1M &LI • ,.0 3 0 1— O. 0 N N ONSULTANT N W 0 r 0 z 2 0 W h 0 E2 0 W w 0 0 L t 1 O LL O O ti co LO 0) d) co O ,r ao O ��'E >O 0 Q co E (0 OHO '— 0 ir°) a) a) N 0 TM 603376 (/) 0_ 2 U 1— w w I- Q 0 w 1- z CO 0 PROJECT #210252 ISSUED / REVISED DATE PROGRESS DRAWING 4/29/10 REVIEW SET 1/14/11 PERMIT SET 1/28/11 PHASE 42, LEVEL 2 POWER PLAN E2.21 10 8 — 9 — 10 — 11 — 12 — 8 — 9 — 10 — 11 — 12 — 8 — 8 LEGEND QA 1 /2 "C (2) #12 & #12 GRND © 1"C (3) #8 & #10 GRND © 1 1/2"C (3)1/0 & #6 GRND 9 — 10 — 8 — 8 9 — 9 8 — 9 8 — 9 m 8 9 HDP --42C C.B. IAHU -4202 10 #2 4 11 — — 12 11 — 12 11 11 12 — 12 N 12 m CV U 11 8 .-- 9 — C2 C1 10 — 10 I ■ , 1 k - 1 ......'.....,.d a r RF -42C2 ..................... aC.B. 21 11 — HDP -42C C.B. RF --42C 1 C.B. #20 B3 11 — 12 8 — 9 —1 8 — 9 - HDP -42B 8 — 9 !-- 8 9 — C.B. #24 D IAHU- 42B2 AHU -42B1 HDP -42B C.B. # 0 -� — 10 B2 B1 A3 HDP -42C C. LEVEL 2 MECHANICAL POWER PLAN 1I8 "1• -0 w �T 4 `i• 12 — RF -42B3 C.B. #22 F -.42B2 .Bj #21 11 — 12 — 11 — 12 B 8 9 HDP -42A C.B. 8 9 #24 HDP -42A C.B. #23 8 9 Al 8 L9 10 10 10 — 10 RF -42B1 C.B. #20 RF -42A3 C.B. #22 11 RF -42A2 C.B. #21 11 12 11 -42A1 #20 _ 12 11 12 11 8 9 �--- 10 HDP -4 C.B. #20 HDP -4 C.B. #21 HD#P -4 12 C.B. #22 11 12 8 9 10 11 R VIEWED FOR CO PLIANCE WITH NFPA70 -NEC FEB 17 2011 12 C o Tukwila BUIL ' ING DIVISION RECEIVED FEB 0 4 2011 PERMIT CENTEF w z CONSULTANT N CO O O CD 0< 0 LL 1 0 LL O E O 0 ti O U coo) N a) OaoQ N N CO CO O O >> N N HILL 3 O O O CD C E >��0 < CO ._�. Lo(01- a) co a) co — W 1 a. TM 603376 0 2 0 w w 1— Z w 0 -J IZ Co CO 00 C) CD 0 N 0 N 1- U W 0 a ISSUED / REVISED DATE PROGRESS DRAWING 4/29/10 REVIEW SET 1/14/11 PERMIT SET 1/28/11 PHASE 42, LEVEL 2 POWER PLAN E2.21M 2 3 4 5 6 8 10 i PDC- 42BD2.1 PDC- 42DB2.1 PDC- 42BD2.2 PDC- 42DB2.2 N E 4 11 El U <C4-1 i v v a ° o- PNL - 42C -L1 CKT #8 0 0 new ww, PNL- 42B -L1 CKT #8 1;1 CV U U D_ 12 14 --- 0 11 - 12 PDC- 42BD1.3 PDC- 42DB1.3 U a_ N N et c) o_ c.. CS 0 IA 142 -02 ' - 11 11 PNL - 42B -L1 CKT #6 12 w� PNL- 42C -L1 CKT #6 I PDC- CD1.1 PDC- DC1.1 1 13 — 0 LEVEL 2 POWER PLAN UB " =1' -0" 11 ,....,. 12 PDC- 42A1.1 PDC- 42A2.1 PDC- 42A1.2 PDC- 42A2.2 14 — ;.. 13 — — 14 — 0 PNL - 42B -L1 CKT #4 12 0 42 -01 PNL - 42C -L1 CKT #4 0 13 12. PDC- 42A1.3 PDC- 42A2.3 . ." 14 ..-- PDC- 42A1.4 PDC- 42A2.4 X11 =�0�2 REVIE . ED FOR COMPLIA CE WITH NFPA - NEC FEB 17 2011 3 City of• ukwila BUILDIN r DIVISION RECEIVED FEB 04 2011 PERMIT CENTER w z v C c Lam 0 0 12 LL a.° " N N 0 CONSULTANT 0 0 ti co LO rn 0) E 0 0 N N N N CO CD 0 0 N N F 11. co 0 CD C E > 0 <co �� 1E al •› '-0 nag) co CU cn NTERGATE EAST CAMPUS TM 603376 CD 00 C) 00 Co 0 N LO N 0 H 0 W 0 Ct a ISSUED / REVISED DATE PROGRESS DRAWING 4/29110 REVIEW SET 1/14/11 PERMIT SET 1/28/11 PHASE 42, LEVEL 2 POWER PLAN E2.22 F E D B A 10 — 6- - 7- - 8- 6 — 7 — 8 — 6 — 7 - 11 — 11 — 8 6— 6 mozoamoci, .1.417440.1.S. 7 8 — 7 m 133 03 7 8 7 8 0 0 0 7k• PNL-42D—L1 CKT 3/4"C (4)#10 & #10 GRND TEMPORARY CIRCUIT TO PN L-42B —L1 CKT #19 9 — 10 — 9 - 10 — ID • 7 8 7 8 ID ID HEAT T C2 —L1 CKT #40 CONNEC ID ID ID 7 7—. La La 7 Id Id Id s..•••K.." 0 Id * ***V400,0=S4W4,1~40:4-440.4%.",,:,..000.04.WIN:N444.4404,.`;.; V,Wit,4:04,414V400,006.40'0404ttitiMA04***NANMVAVV0W v#1>AAttoo, .44.4.4•41t+4‘••• 01,'**N. Nte.4-0•4.4.v4.%-•••'N.v 'A* ts..,••■ •1tS • Si ,10; .1•TS .. CA% Lsal, IteoS :WSW HEAT TRACE CONNECTION 10 11 ID LO ID 03 ID 10 10 11 0 9 Cl•VL at. WAS PNL-42D--L1 CKT #40 TEMPORARY CIRCUIT TO PNL-42B—L1 CKT #38 0 0 10 11 XS; eSk•Si !RR WA▪ R GSS. 4.210. .10 • al. ah`li 9.02 •I‘S. SAS, f.•IL 'MI • 9 10 11 ID 0 ID 0 0 ID 9 _ 10 — 9 - 10 — ROOFTOP POWER PLAN 1/13"•1•-0" 7 8 — 7 '16 6 6 MAMMON. QS IdltxID NSidIIM lIk MitIONSMINSO :Mt./MR, • • • • • 7 — Ct.. 12*.) 7 C3 ID 0 0 ID 0 6 SMSNiSSMIIi.• 7 t / hst7,1 10. 6 xaveox.....xo < /5:2/ 8 ID WeS LIM • .721: ,S5:42 • . r.sk+S 7.1 ,KSZ 9 — La Id Id 10 — La Id 9 - 10 — 11 .1. • CO., ) 9 I- 10 4- L. Lt. 9 10 9 10 ID ID ID ID 9 10 ID 11 — 7 8 7 ( 7 8 8 PNL-42B—L1 CKT I #40 PNL-42B—L1 CK 3/4"C (4)#10 & 9 10 11 •— #11 #10 GRND 9 10 *1""' 7-- LL' 7 9- 10 8 9 10 REVIEWED FOR COMPLIANCE WITH NFPA 70 • NEC FEB 17 2011 I City o Tukwila BUILDING DIVISI N RECEIV61) FEB 04 2011 PERMIT CENT R z CONSULTANT TM 603376 CO 0 CN1 CNI 0 CV w --) 0 ISSUED / REVISED DATE PROGRESS DRAWING 4/29/10 REVIEW SET 1/14/11 PERMIT SET 1/28/11 PHASE 42, ROOFTOP POWER PLAN E2.R1 2 3 4 5 6 7 8 9 10 cp co v- 03 6 matattamotatatam mat uJ z 1- LO 0) E 0 0 N CO .0 N Cn 0 F E COORDINATE FUSE DISCONNECT LOC MECHANICAL PRIOR TO INSTALLATION [C>- FIELD VERIFY EQUIPMENT CLEARANCS TO INSTALLATION. FIELD VERIFY COMBO MOTOR STARTR CLEARANCES PRIOR TO INSTALLAT1011. mamaattaaMattmamittitMamammma, ,:-..z. .,:: ..„ ....,... ::- ‘MM,Mataitataaam,a,matmstmmamm, HDP-42D C.B. #37 1"C (3)#6"s & #8 GRND ONSULTANT D H8T-42D 8 C.B. #35 HDP-42D (2)3" (3)600's & 1/0 GRND 15P-42C C.B. #35 8 a)3" (3)600's & 1/0 GRND 0 HDP-42B C.B. #37 1"C (3)#6"s & #8 HDP-42B C.B. #35 (2)3" (3)600's & 1/0 GRND HDP-42D C.B. #34 (2)3" (3)600's & 1/0 GRND TEMPORARY CIRCUIT TO HDP-42C C.B. #30 'XS ...... ........ .4% HDP-42C C.B. #36 inc (3)#6s & #8 GR D HDP-42D C.B. #36 1"C (3)#6"s & #8 GRND TEMPORARY CIRCUIT TO PNL-42C C.B. #8 HDP-42B C.B. #34 (2)3" (3)600's & 1/ HbP-42C C.B. #34 (2)3" (3)600's & 1/0 GRND B REVIEWED F H COMPLIANCE WITH NFPA 70 - NEC FEB 17 2011■ 1 0. 0 (0 w • O� < < o a. co cf) < < (.1 w cu 1— • 7- < O Lo W c€) I- I— ten z CO 0 LO 0 Cs1 1- w 0 TM 603376 ISSUED / REVISED DATE PROGRESS DRAWING 4/29/10 REVIEW SET PERMIT SET 1/14/11 1/28/11 A ROOFTOP MECHANICAL POWER PLAN 1/8N1'4" PHASE 42, ROOFTOP POWER PLAN E2.R1 M F E D c 8 A PNL -42C CKT (�9w n PNL -42B CKT #1 w F PNL -42B CKT #1 PNL -42C CKT #1 F E WALL MOUNT BEHIND CRAC UNITS G — z:I w C ( BATT. STS STS STS ( STS 11 F — STS ( C BATT. STS STS c 1 B H0BAIT. N 1 0�1 F — N G 0 • H-0 i T: C 1-0-1-0 I F F 1 STS STS ifs C F� I--0 i 01 ( F B BATT. F F ( 0 LEVEL 1 UPS ROOM LIGHTING LAYOUT va ° =•-0° G — F — G — REVIEWED FOR COMPLIANCE WITH NFPA70 - NEC FEB 1 7 2011 City of Tukwila BUILDING DIVISION! RECEIVE' FEB 04 2011 PERMIT CENTEE w z CONSULTANT 0 0 J 0 z x 0 0 EE 0 w J w Fourth Floor e— N e- 0 E 00• 0 O Q co o) ▪ • >, ?j r N d) co CO .D N N N ca co cn co }' 0 0 ?� N N N V) F LL co O r ao co c E iO -0 <CO _�cj ca c a aS co cu D-w g U co W < < CO J (/) U 000 = �a 0. w a o s N N co I— (,) a w M co Z TM 603376 0 N N O N 1- U w 0 a ISSUED / REVISED DATE PROGRESS DRAWING 4/29/10 REVIEW SET 1/14/11 PERMIT SET 1/28/11 PHASE 42, LEVEL 1 UPD RM LTG LAYOUT E3.11 F E D B A - 12 - 12 - 12 - 12 - 1 1 12 - 12 - 12 C BATT. 13 13 C 1-1-o-+-0 !I- B 1- -0-1 -0 i 13 13 - 13 C BATT. 14 - 14 - 14 - 14 14 - B 12 12 1 ! 12 - 12 - 12 - 12 _. ._-- -.__._ I O C BAIT. SMMVSattaUt r B BAIT. I BAIT. 13 - 13 - ..... Mit= . I-O I 0-"ill 13 - 13 B 1--O 12 t- 12 PNL -42C CKT #3 PNL -42B CKT #3 12 ;r' PNL -42C CKT #3 BAIT. o -* 13 13 PNL -42C CKT #3 PNL -42B CKT #3 PNL -42C CKT #3 14 - 14 14 LEVEL 1 GENERATOR ROOM LIGHTING LAYOUT 1/4 " =1' -0" 14 .- .. 14 - - - _. .. 14 —t- 4 - 14 Lt I(:'02 FOH 1 L A C COMPLIANCE WITH NFPA 70 - NEC FEB 17 2011 iwwo oivi RECEIVE) FEB 04 2011 PERMIT CENTER "o ill CO L4,1 CC — co 1- 0 N N ONSULTANT O O O 1.0 0) O ` ti O V 0 Q o 0 • r N 0 LL oCO _ca N N cu CO CO N O O ?� 7 CO 0 N N N U) I— li w 0 0 1111K-51 0 0 z I CO- NJ 0 W(o c p 0 )o °q � Qao�cd 0o�m Ill tim2> w d. w 6O L1) a. N cv 0 CO C/) W U o0 W << J y ° Q CO 4 H Q Q W o N N W c6 di I-- V Q Cn v, W c1) F- I- M Z TM 603376 ISSUED / REVISED DATE PROGRESS DRAWING 4/29/10 REVIEW SET 1/14/11 PERMIT SET 1/28/11 PHASE 42, LEVEL 1 GEN RM LTG LAYOUT E3.12 F E D c A 5 6 7 8 9 10 - — 7 — — — 8 — - — 9 — 10 — 7 — 8 — 9 — 10 — 7 — 1— 9 10 — 7 co 7 7 ® 1/2 "C (2) #12 & #12 GRND PNL- 42C —H1 CKT #5 PNL -�42B —H1 CKT #5 7 8 7 7 7 — 7 7 — 7 7 7 0 7 7 8 8 _.._,_... 8 f...1 8 — 8 7 8 IC ATT. 0 �— 10L W F-0—+-0 O—±—O 1 9 9 i--- O— I - -O�"I 1- 1--0 --1-0 1 C BATT. 1-0—F-0 1 1-0-1-0-11 1-0-1t-0 F C O— F� - -BATT. • ... f .... ....... ...E..... ... ' 1 11 9 L- 9 9 C BATT. 10 — I 10 —! Lw 10 <l C 1. 1-0-1--0 1 U C BATT. 10 — 9 I C O —t—O�I 9 9 9 9 • 1p — F—B —O—i —O 10 H i li ± 9 C BATT. 10 — 10 C BATT. 1.10.4_40 9 10 L_J C BATT L I-- 10 LEVEL 2 LIGHTING LAYOUT 118 ° =1' -0" f/L11--001T 7 8 9 -1— 10 7 8 9 10 RE IEWED FOR COMPLIANCE E WITH NFIPA 70 - NEC FEB 17 2011 C BUIL of Tukwila ING DIVISION RECEIVED FEB 0 4 2011 PERMIT CENTER 7 8 9 1c w z "a m CONSULTANT O ti CO N CD O N co 0 00 rn CD C E >000 < O C (0 _c ?..<, O •›, O LOa ai c0 a) Lc" 0) MIN v 0 TM 603376 vl U F— w w F— Q 0 Lo ce w co I— co z w 0 J 0 00 c0 00 0) Q cu CD 0 N Ln N 0 1- 0 W 0 0 ISSUED / REVISED DATE PROGRESS DRAWING 4/29/10 REVIEW SET 1/14/11 PERMIT SET 1/28/11 PHASE 42, LEVEL 2 LIGHTING LAYOUT E3.21 5 6 9 10 - - 12 - - - 13 - - - 14 - - - 15 - - 16 - 11 - 11 - PNL- 42C —H1 CKT #11 12 - 13 - 14 - 15 - 16 - 12 - 13 - 14 - 15 - 11 m 14 -> m 14 14 11 - 12 13 14 - 15 11 - 12 13 14 15 0 0 0 0 0 0 0 16 16 16 16 0 0 11 12 13 14 15 11 12 13 14 15 PNL- 42B —H1 CKT #11 0 0 L. 11 11 - 0 W t-- j W 12 • 12 12 - 1�- 0 W 0 :;'1 W 13 13 - - 13 - 13 - 0 W 1 0 W TT- 14 14 14 - 14 - 0 W 0 15 15 W 15 - 15 - 0 1 °.r 16 16 9 W 16 0 16 16 LEVEL 2 POWER PLAN 118 " =1' -0" 1 11• - 12 - 12 12 • MEET NOTS9 CIRCUIT TO LOCAL CIRCUIT SERVING AREA, TYP. 13 - 13 - 13 - 13 - 12 - 11 13 12 - _ 14 14 - 14 14 14 14 CP 15 15 15 15 15 15 PN.L- 428 -141 CKT #7. 16 16 fL1 0 0 16 16 16 11 - 12 - 13 14 5 11 1 <' 1, 1: C6MpLIEANCE WITH ,IJFPA70 - NEC FEB 11 2011 City of Tukwila ING DIVISI N RECEIVED FEB 0 4 2011 PERMIT CENTER w z 0 v > N 1 wva co t0 O — cp O E O lf) N. ) 0 O < co O) •+ Y 0 CsI 0) O CO c N N CO O 0 1 O O N O N N N O a) — LI cO IH ti CONSULTANT v I 0 Q N a I- X co Q W N di I- 0< 0 N 1— Z TM 603376 W U J 0 00 v- 00 0) M CO 0 N '^ Y ) 0 1- U w 0 ISSUED / REVISED DATE PROGRESS DRAWING 4/29/10 REVIEW SET 1/14/11 PERMIT SET 1/28/11 PHASE 42, LEVEL 2 LIGHTING LAYOUT E3.22 F E D B A 1 2 3 4 5 6 7 8 9 1 0 6 — 7 — 8 — 9 — 10 — 11 — 7 8 7 8 - 7 — 8 — PNL-42D—L1 CKT #13 TEMPORARY CIRCUIT TO PNL-42B—L1 CKT #17 10 — 11 — 11 0 6— 6— 6 6 6 6.04.04M 8 000.0.0. 0400.104.0 .0.4.000 3:000.004., M .400.40 K•X .04•404.= «t M.M448•410 01.00=0.0x azamm=001 7 0 0 m 0 7— 7 m 0 — m COORDINATE LOCATIONS WITH SERVICE COVERS FLUORESCENT WALL PACK 8 — 8 0 0 7 8 7 8 PNL-42C—L1 CKT #13 7.0 i 0 6 6 7.4.00.40 8:10.0:040:k M 10013000MM 1,0 M..0.14:0101 0 30.00444. 0:0044430 0 0 0 0 0 7 7 — 8 8 \ r ( 6 1000.0m00 N 404.044.1 MM.M.M40 0 4J 7 — LJ 6 - 8 0 0 tJ 9 - 10 — 11 10 11 Me. 9 ...... •• ••• 9 10 10 0 0 0 0 0 ;..10.7.2, • ••• ti..0 4)--• 9 10 9 10 ..><1 0 004 0,73 w 9 9 — ....... •-.00 ....... 1 9- 0 UJ 0 0 0 10 10 — ROOFTOP LIGHTING LAYOUT 1/8"..1.-0" 10 11 — 7 — 8 — .4, 6— 6 — las 00:0000»0 gke 00400.0x 0 0:01:000,0 00k00m002 4. a - 6 - Mi02400M. 0041.4040 00.100.10. 0.0.424.0 0.000.0. 0 6 — 7— 7 — 8 8 — 0 0 0 0 7 — 6 0000 .1.` MORO 02 6 - 0000:0100 0 00:a2 0.0103000ti ............. \ ' 8 PNL-42B—L1 CKT #13 lemegialV•4% ANNSA•409,4 4;,,Milt•-'4W4P"r"..."** 4444 r•re04$ tft,"40044",04#44•Atx40440~",..,4M-V-4544,0.4%,',‘,...04.4.21WW.,•,404 +4,4*.tiit*+#0•04,1*-04444.74-#4400404,1,',,ar•-•-www.44,4weit0v-wro ..",0#11.40##.0.4. voavakatilwAtiVANiwari4x0vMeo 9 — 10 — 7>< N',1000, *ex4•4004,14W40.04'.40.444004$•‹:. 4,44:044,04.10P0400•P$440 w,w,V,x4414,40••••••,00 44-0•0•04•4\"%***444.**********404:44.<44: 010.•4,4100044,04,04.00.4•04004,•%.44Wip.,w4V4W.A4VP400,41 1,...,*,..••••k \.**. %-00.4•V••:?"4-4 * '•••-10\4*-0,,..***44 NoN 9 9 — 0 0 9 10 10 0 10 10 0 0 0 7 8 9 10 11 X 7 8 9 10 8 9 10 .. .. : I ...... ' ssk,14,..stmaa.keani::: 8 — 9 REVIEWED OH COMPLIANCE WITH NFPA 70 • NEC FEB 17 201i° —City of •Tulcw la BUILDING DIVI IQN RECEIVED FEB O4211 PERMIT CENTER CONSULTANT ILJ 0 0 z 0 0 w 1 w s- 0 0 LJ- 1 0 0 E o 0) �o) • C 00 00 ID N N CD CD 00 N N I= U. co co CD C 1-1-ht 0 0 > < CO .0 ><E h. co •>. co Loa. a) (/) CO CD 00 0) TM 603376 ISSUED / REVISED DATE PROGRESS DRAWING 4/29/10 REVIEW SET 1/14/11 PERMIT SET 1/28/11 PHASE 42, ROOFTOP LIGHTING LAYOUT E3.R1 E D 0 B A 2 3 4 5 6 7 8 9 10 DATA tENT-Eit P-RD P 3112011 1349 Equipment Tag Description Location Voltage Phase Motor HP/BHP Disconnect Panel Permanent Circuit Temporary Circuit Raceway CH-42-B1 CH-42-B2 CH-42-C1 CH-42-C2 335 Nominal Ton Roof Chiller 335 Nominal Ton Roof Chiller 335 Nominal Ton Roof Chiller 335 Nominal Ton Roof Chiller Rooftop CH-42-D1 335 Nominal Ton Roof Chiller _ ... CH-42-D2 335 Nominal Ton Roof Chiller Rooftop Rooftop 480V 30 Rooftop 460V 30 Size N/A N/A N/A N/A N/A N/A N/A 800A N/A 800A N/A 800A N/A 800A HDP-42B HDP-42B HDP-42C HDP-42C CB # 35 CB # 36 Conductors Remarks Equipment Tag (2) 3" EMT (3) 600s & 1/0 GRND Confirm Fuses Not Required (2) 3" EMT (3)600's & 1/0 GRND Confirm Fuses Not Required (2) T EMT (3) 600's & 1/0 GRND Confirm Fuses Not Required (2) r EMT (3) 600s & 1/0 GRND Confirm Fuses Not Required VECA HDP-42D CB # 34 HDP-42C #7 (2) 3" EMT — VECA HDP-42D CB # 35 N/A (2) r EMT (3) 600s & 1/0 GRND Confirm Fuses Not Required CH-42-B1 CH-42-B2 CH-42-C1 CH-42-C2 CH-42-D1 (3) 600s & 1A GRND Confirm Fuses Not Required CH-42-02 CHP-42-B1 Chilled Water Pump For Chiller Loop Rooftop 480V 30 30/23 CHP-42-B2 CHP-42-C1 CHP-42-C2 CHP-42-D1 CHP-42-D2 AHU-42-A1 Chilled Water Pump For Chiller Loop Rooftop 480V 30 30/23 Chilled Water Pump For Chiller Loop Rooftop 480V 30 30/23 Chilled Water Pump For Chiller Loop Chilled Water Pump For Chiller Loop Chilled Water Pump For Chiller Loop Rooftop Rooftop 30/23 VECA 60A VECA VECA 60A VECA HDP-42B CB # 36 60A 60A VECA HDP-42B 60A 80A VECA HDP-42C CB # 36 (1) 1-1/4' EMT (3) #6's & #8 GRND CB # 37 CB # 37 CB # 36 CB # 36 HDP-42C HDP-42D CB # 37 CB # 36 CB # 37 HDP-42C #8 HDP-42D CB # 37 (1) 1-1/4" EMT (3) #6's & #8 GRND (1) 1-1/4" EMT (3) #6's & #8 GRND (1) 1-1/4" EMT (3) #6's &#8 GRND (1) 1-1/4" EMT (3) #6's & #8 GRND (1)1-1/4" EMT (3) #6's & #8 GRNO CHP-42-B1 CHP-42-B2 CHP-42-C1 CHP-42-C2 CHP-42-D1 CHP-42-D2 Data Center Air Handlers 2nd Floor Mech AHU-42-A2 Data Center Air Handlers 2nd Floor Mech 480V 30 72/72 AHU-42-B1 Data Center Air Handlers 2nd Floor Mech 480V 30 72/72 AHU-42-B2 Data Center Air Handlers 2nd Floor Mech AHU-42-C1 Data Center Air Handlers 2nd Floor Mech AHU-42-C2 ... AHU-42-D1 AHU-42-D2 Data Center Ali* Handlers ----- Data Center Air Handlers Data Center Air Handlers 480V 30 72/72 480V 30 72/72 2nd Floor Mech 480V 30 2nd Floor Mesh 480V 30 2nd Floor Mesh VFD VFD VFD VFD VFD VFD VFD VFD Hermanson Herrnanson Hermanson Hermanson Hermanson Hermanson Hermanson Hermanson N/A N/A N/A N/A HDP-42A CB #23 HDP-42A CB 424 HDP-42B CB #23 N/A N/A (11 1-1/2 EMT (3) #1/0's & #6 GRND VFD with Factory Disconnect (1) 1-1/2" EMT (3) #1/0's & 43 GRND VFD with Factory Dlsconnect (1) 1-1/2° EMT (3) #1/0's & #6 GRND VFD with Factory Disconnect N/A N/A N/A HDP-42B CB #24 N/A (1)1-1/2 EMT —L_ N/A N/A N/A HOP-42C CB #23 N/A (1) 1-1/2" EMT N/A N/A N/A N/A (3) #1/0's & #6 GRND VFD with Factory Disconnect (3) #1/0's & #6 GRND VFD with Factory Disconnect HDP-42C CB #24 N/A (1) 1-1/2" EMT (3) #1/0's & #6 GRND VFD with Factory Disconnect HDP-42D CB #23 N/A (1) 1-112" EMT (3) #1/0's & #8 GRND VFD with Factory Disconnect HDP-420 CB #24 (1)14/2"EMT (3) #1/0's & #6 GRND VFD with Factory Disconnect AHU-42-A1 AHU-42-A2 AHU-42-B1 AHU-42-B2 AHU-42-C1 AHU-42-C2 AHU-42-D1 AHU-42-D2 RF-42-A1 RF-42-A2 RF-42-A3 Data Center Fan Array Data Center Fan Array Data Center Fan Array 2nd Floor Mech 2nd Floor Mech 480V 2nd Floor Mech 480V RF-42-B1 Data Center Fan Array 2nd Floor Mech 480V RF-42-B2 Data Center Fan Array 2nd Floor Mech 480V RF-42-B3 RF-42-C1 RF-42-C2 RF-42-C3 RF-42-D1 RF-42-D2 RF-42-D3 TF-42-C1 Data Center Fan Array 2nd Floor Mech Data Center Fan Array 2nd Floor Mach Data Center Fan Array Data Center Fan Array Data Center Fan Array Data Center Fan Array Data Center Fan Array 2nd Floor Mech 2nd Floor Mech 2nd Floor Mech 2nd Floor Mesh 2nd Floor Mech 36/27.42 36/27.42 36/27.42 36/27.42 36/27.42 VFD & Controller Hermanson VFD & Controller Hermanson VFD & Controller Hermanson 30 36/27.42 30 36/27.42 36/27.42 36/27.42 36/27.42 480V 30 36/27.42 480V 30 36/27.42 VFD & Controller Hermanson VFD & Controller Hermanson VFD & Controller Hermanson VFD & Controller Hermanson VFD & Controller Hermanson VFD & Controller Hermanson N/A N/A N/A N/A HDP-42A N/A HDP-42A CB #21 N/A HDP-42A CB #22 N/A N/A HDP-42B HDP-42B CB #20 N/A N/A N/A HDP-42B N/A N/A HDP-42C VFD & Controller Hermanson VFD & Controller VFD & Controller Hermanson Hermanson HDP-42C HDP-42C CB #21 N/A CB #22 N/A CB #20 N/A HDP-42D CB #20 N/A HDP-42D CB #21 N/A HDP-42D CB #22 (1) 1" EMT (3) #8'S & #10GRND VECA to Mount VFD/Controller. Hermansan to Denver to 2nd Floor RF-42-A1 (1 ) 1 EMT (3) #8'S & #10GRND VECA to Mount VFD/Controller " (1) 1" EMT (3) & #10GRN D R VECA to Mount VFD/Conttoller HHenne7newonn t: DeDell:rr 2nd F d FIal'oorr RF4F-422--A3A2 (1) 1" EMT (3) #8'S & #10GRND vEcA to Mount VFD/Controller. Hermanson to Deliver to 2nd Floor (1) 1" EMT (3) #8'S & #10GRND VECA to Mount VFO/Controller. Hennanson to Deliver to 2nd Floor (1) 1" EMT (3) #8'S & #10GRND VECA tO MauMVFD/Controller. Hermanson to Deliver to 2nd Floor (1)1" EMT (3) #8'S & #10GRND vEcA RkArnt VFD/Controller. Hermanson to Denver to 2nd Floor (1) 1" EMT (1) 1" EMT (3) #8'S & #10GRND VECA to Mount VFD/Contnaler. Hermanson to Denver to 2nd Floor (3) #8'S & #10GRND VECA to Mount VFO/CoMrolktr. Hermanson to Deliver to 2nd Floor (1)1" EMT (3) #8'S & #10GRND VECA to Mount VFD/Conbolter. Hermanson oD.Ib.00io 2nd tqcor NIA (1) 1" EMT N/A (I) I" EMT RF-42-B1 RP-42-B2 RF-42-B3 RF-42-C1 RF-42-C2 RF-42-C3 RF-42-D1 RF-42-D2 RF-42-D3 Terminal fan to move hot air from Ups Room to Gen Room SDC-42-Gen Room VFD & Controller Hermanson HDP-42C (1) 1/2" EMT (3) #12'S & #12GRND TF-42-C1 EF-42-B1 EF-42-C1 CRAC-42-B1 CRAC-42-C1 CRAC-42-D1 CP-42-B1 Generator Room Exhaust Fan Generator Room Exhaust Fan UPS Room Cooling SDC-42-Gen Room SDC-42-Gen Room 1.5/1.28 1.5/1.28 HDP-42C VECA HDP-42B UPS Room Cooling UPS Room Cooling — SC-42-UPS Room (3)3.9 72.5A SDC-42-UPS Room 480V 30 (3)3.9 SDC-42-UPS Room 480V 30 (3)3.9 72.5A N/A N/A N/A N/A HDP-42B N/A HDP-42C N/A HDP-42D CB 438 CB #38 (1) 3/4 EMT (2) #10'S & #10GRND Controliled Via Line Voltage T—Stat 90* (1) 3/4 EMT (2) #10'S & #10GRND Controliled Via Line Voltage T—Stat 90* (1) 1-1/4° EMT (3) #2's & #8 GRND Single Point Connection To Unit N/A (1) 1-1/4'' EMT (3) #2's &#8 GRND Single Point Connection To Unit HDP-42C #30 (1) 1-1/4'' EMT (3) #2's & #8 GRND Single Point Connection To Unit UPS Room Condensate Pumps SDC-42-UPS Room PNL-42B-L1 CP-42-C1 UPS Room Condensate Pumps SDC-42-UPS Room 120V 10 1/3 N/A PNL-42C-L1 CB #2 EF-42-B1 EF-42-C1 CRAG-42-B1 CRAG-42-C1 CRAC-42-D1 to 1/2 EMT (2) #12'S & #12GRND Connect to Pump Controller Fumish/Mounted by Hermanson CP-42-B1 (1) 1/2" EMT (2) #12'S & #12GRND Connect to Pump Controller Fumish/Mounted by Hermanson CP-42-C1 *ALL CONDUCTORS ON THIS SHEET TO BE COPPER* REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC FEB 1 7 2011 ."'"""bity of Tukwila BUILDING DIVISION RECEIVED FEB 04 2011 PERMJTCENTER uj z ONSULTANT s— o LL co CO CN co olt.; E CO C I-1-1 0 0 < CO E _C 1E h., co •• a) LO 0) 0) co 1 0. TM 603376 w -J 0 00 CO 0) CO Cv, ISSUED / REVISED DATE PROGRESS DRAWING 4/29/10 REVIEW SET 1/14/11 PERMIT SET 1/28/11 PHASE 42, MECHANICAL EQUIP. CONNECTION SCHEDULE E5.00 3 4 5 8 10 z 5 "C. 3#350KC M,1 210 GROUND :4`22ft) NEU1 RA D- B TO SITE POWER DI TRIBUT ON EXISTING :KV SW TCHGEAR MSG-2 FLAG NOTES: PROVIDE THIMBLES FOR DC CABLES NOT USED NOT USED > NOT USED NOT USED PROVIDE STATUS NOTIFICATION OF BREAKER POSITION MONITOR AMPERAGE ONLY VIA ACL MONITORING > BYPASS ISOLATION OPEN TRANSFER > (3) OUTPUT BREAKERS 350A 10 PROVIDE FUNCTIONALITY FOR BMS TO MONITOR BREAKER STATUS >> PROVIDE 125A OUTPUT BREAKER TO :WE POWER DISTRIBUTION 3 -LA BRIT ( z 3 "C, 3#35oKctri, 1#2/0 GROUND 1 #2/0 NEUTRAL 1200 MRCT 1200 MRCT 1200A M1 52-1 IC MICROPROCESSOR EASED RE ,AY AND METERING 120(J 52.-2 NC BUS 27KV, 3P11, 4W, 1200A Ill" j 2 K , 3'H, 4W: 1200A BUS B00:5 MRCT CNP) 1200A 52-F1 600;5 MRCT (typ) f 51........ ,st 3T„ 3 1200A 82 -F2 1200A e d 52 -F3 1200A wa 12:0A 1 52 -F5 1200A 52 -F CT; . 3 SINGLE CA =RL.E #350 /(CMIL. 35I r • & 1# 210 GROUND h "C: - 3 -1S:'.•. #350KCM €L, 35KV, & 1# 2.i0 GROUND FEEDER SCHEDULE 3 —PHASE 4 WIRE + GROUND COPPER CONDUCTORS SYMBOL FEEDER SIZE — CONDUIT & WIRE SIZE + GROUND 504 1 "C -4 #6& 1 #10G 604 1 1/4"C — 4 #4 & 1#10G 704 1 1/4"C — 4 #4 & 1 #8G 1004 1 1/2 "C — 4 #1 & 1 #8G C5o44 2 "C — 4 #1/O & 1 #6G 0 24 "C — 4 #4/0 & 1 #4G / (4004) (gm) 3 -1/2 "C — 4 #500KCMIL & 1 #2G (2 SETS) 3 "C 3 #500KCMIL & 1 #1/0 NEUT. & 1 #1/0 GROUND 10004 (3 SETS) 3 -1/2 "C — 4 #400KCMIL & 1 #2/0 PER SET 30004 (8 SETS) 4 "C 4 #500KCMIL & 1 #400KCMIL G PER SET C000) (10 SETS) 3.5 "C 3 -600, 1 -4 /ON, 1 -500G PER SET LOADBANK SWBD LOCATED IN SDC 52 UPS BOOM LOADBANK SWI O ;p� 3000A 460v 3P3W IMO TO HDP 5$A —4• TO HDP 52 Lrn— TO HOP 520 TO HDP 52D BUSWAY 3000A BUSWAY FEEDER SCHEDULE 3 —PHASE 3 WIRE + GROUND COPPER CONDUCTORS SYMBOL FEEDER SIZE — CONDUIT & WIRE SIZE + GROUND 203 1/2 "C — 3 #12 & 1 #12G (;(7:3) 3/4 "C — 3 #10 & 1#10G C4-(;) 3/4 "C — 3 #8 & 1#10G 503 3/4 "C — 3 #6 & 1#10G 703 1 "C — 3 #4 & 1 #8G 1003 2 "C — 3 #1 & 1 #8G 1503 2 "C — 3 WO /0 & 1#6G 2003 2 "C — 3 #4/0 & 1#6G 2503 2 -1/2 "C — 3 #250KCMIL & 1 #4G 4003 3 "C — 3 #500KCMIL & 1#2G 5003 (2 SETS) 2 -1/2 "C — 3 #250KCMIL & 1 #2G 6003 3 -1/2 "C — 6 #350KCMIL & #1 /O G 6003 (2 - SETS) 3 "C — 3 #500KCMIL & 1#1/0 PER SET 12003 (3 SETS) 3-1/2"C — 3 #600KCMIL & 1113/0 PER SET 16003 (4 SETS) 3 -1/2 "C — 3 #600KCMIL & 1 #4 /OG PER SET 20003 (5 SETS) 3 -1/2 "C — 3 #600KCMIL & 1 #250KCMIL PER SET 2eoo3 (6 SETS) 3 -1/2 "C 3 #600KCMIL & 1 #350 KCMIL G PER SET 30003 (8 SETS) 3 "C 3 #500KCMIL & 1#400KCMIL G PER SET 40003 (10 SETS) 3 -1/2 "C 3 #600KCMIL & 1 #500KCMIL G PER SET FUTURE AJERNAT: FUTURE ALTERNATE E5.11 E5.12 E5.13 Ett 1 - REVIEWED E FOR COMPLIANCE � NEC NBC NFP FEB 17 2011 City p�iS ILDIN 10N RECEIVEr FEB 0 4 2011 PERMIT CENTER w z • c CZ co F— C N N Fourth Floor CONSULTANT N co (0 o - E aoo� ti o) U Q co C) • �N a) co co ID N N cu CD- cn (O • o o >r. N N 3 (n F N. 0_ W Q y U a I- a w N w I- 0 1 w F— z TM 603376 w O o0 Q 0_ co 0) ISSUED / REVISED DATE PROGRESS DRAWING 4/29/10 REVIEW SET 1/14/11 PERMIT SET 1/28/11 F E C B A 10 ( 2) 6 "C, 333:350KC:'::S`, is #2 /V GROUND i#2 /? NEUT ?_ ..., . 1 TO BITE POWER DISTRIBUTION EXISTING 27KV SWITGHGEAR SG 2 FLAG NOTES: PROVIDE THIMBLES FOR DC CABLES NOT USED NOT USED NOT USED NOT USED PROVIDE STATUS NOTIFICATION OF BREAKER POSITION MONITOR AMPERAGE ONLY VIA ACL MONITORING © BYPASS ISOLATION OPEN TRANSFER (3) OUTPUT BREAKERS 350A 10 PROVIDE FUNCTIONALITY FOR BMS TO MONITOR BREAKER STATUS 11 PROVIDE 125A OUTPUT BREAKER TO SITE POWER DISTRIBUTION , 2) 8 "C, 3 #350KCM, 1:`x2/0 GROUND 1 #2/0 NEUTRAL FEEDER SCHEDULE 3 —PHASE 4 WIRE + GROUND COPPER CONDUCTORS SYMBOL FEEDER SIZE — CONDUIT & WIRE SIZE + GROUND 1 "C — 4 #6 & 1 #100 (504) 604 1 1/4 "C — 4 #4 & 1 #10G 7oa 1 1/4"C — 4 #4 & 1 #8G loos 1 1/2 "C — 4 #1 & 1 #80 1504 2 "C — 4 #1/0 & 1 #6G 0 24 "C — 4 #4/0 & 1 #40 aoo4 3 -1/2 "C — 4 #500KCMIL & 1 #20 6004 (2 SETS) 3 "C 3 #500KCMIL & 1 #1/0 NEUT. & 1 #1 /0 GROUND 10004 (3 SETS) 3- 1/2 "C °:- 4 #400KCMIL & 1 #2/0 PER SET 30004 (8 SETS) 4 "C 4 #500KCMIL & 1#400KCMIL G PER SET C000..4) (10 SETS) 3.5 "C 3 -600, 1 -4 /ON, 1 -500G PER SET 3. LA , 3 -LA UH 1200 MRCT 1200:1 MI 32 -1 NC MICROPROCESSOR BASED RELAY AND METERING Penne s,1k 1200A a2 -2 NC LOADBANK Sint /BU LOCATED IN SDC 52 UPS ROOM BUS 27KV, 3Ph, 4W, 1200A 3U N.O. 52 -3 rsk 2 ?KV, 3PH, 4W, 1200A BUS OKI BUS 2 6€00:5 MRCT w) 1200A 52 -F1 1200A 52 -F2 1200A 52 -F3 600:5 MRCT OW) 1200A 52 -F4 1200A 52 -FS r3"c; - :Y SINGLE CABLE #350KCMIL. 35KV & 1# 210 GROUND 41- 2 S$URCE 1 1 5 "C - 3 -1 /C #350.KCMIL, 35K;{, & 1# 210 GROUND TO HDP 52A TO HDP 52B TO HDP 52C - ► TO HDP 52D OOOA BUSWAY FEEDER SCHEDULE 3 —PHASE 3 WIRE + GROUND COPPER CONDUCTORS SYMBOL FEEDER SIZE — CONDUIT & WIRE SIZE + GROUND 203 1/2"C — 3 #12 & 1#12G 303 3/4 "C — 3 #10 & 1#10G 403 3/4 "C — 3 #8 & 1 #10G 503 3/4 "C — 3 #6 & 1#10G 703 1"C — 3 #4 & 1#8C 1003 2 "C -3 #1 &1 #8G (503 2 "C — 3 #1/0 & 1 #6G 020033) 2 "C — 3 #4/0 & 1#60 2503 2 -1/2 "C — 3 #250KCMIL & 1 #4G (4003) 3 "C — 3 #500KCMIL & 1#20 5003 (2 SETS) 2 -1/2 "C — 3 #250KCMIL & 1 #20 6003 3 -1/2 "C — 6 #350KCMIL & #1/0 G 8003 (2 SETS) 3 "C — 3 #500KCMIL & 1#1/0 PER SET 12003 (3 SETS) 3 -1/2 "C — 3 #600KCMIL & 1 #3/0 PER SET 16003 (4 SETS) 3 -1/2 "C — 3 #600KCMIL & 1 #4 /0G PER SET 20003 (5 SETS) 3 -1/2 "C — 3 #600KCMIL & 1 #250KCMIL PER SET 25003 (6 SETS) 3 -1/2 "C 3 #600KCMIL & 1 #350 KCMIL G PER SET 30003 (8 SETS) 3 "C 3 #500KCMIL & 1#400KCMIL G PER SET C000D (10 SETS) 3 -1/2 "C 3 #600KCMIL & 1 #500KCMIL G PER SET FUTUR .. ALTERNATE 3000A BUSWAY FUTURE ALTERNATE &LI 1 ool� REVIEWED FOR COMPLIANCE ITH NFPA 70 FEB 17 2011 City of Tukwila BUILDING DIVISION RECEIVED FEB 04 2011 PERMIT CENTER w z o' m cc co 0 N CONSULTANT L O LL 0 0 ti co co 0 T co cm'a) co E 0 >0 O0 < to 0. `crO� �O a) ca a) U) LO Cs) 0) CO N CJ 0 N TM 603376 2 0 1- (/) w w 1-- a w H Z w O CO < c0 J 0— 00 0) Q N (1) M M CD O N u) (N O N F- 0 w 0 a ISSUED / REVISED DATE PROGRESS DRAWING 4/29/10 REVIEW SET 1/14/11 PERMIT SET 1/28/11 PHASE 42 ONE -LINE DIAGRAM E5.11 B A 10 FLAG NOTES: PROVIDE THIMBLES FOR DC CABLES NOT USED NOT USED NOT USED NOT USED PROVIDE STATUS NOTIFICATION OF BREAKER POSITION MONITOR AMPERAGE ONLY VIA ACL MONITORING BYPASS ISOLATION OPEN TRANSFER (3) OUTPUT BREAKERS 350A 10 PROVIDE FUNCTIONALITY FOR BMS TO MONITOR BREAKER STATUS PRnvinF 19.riA f111TPIIT RRFAKFR DIST. SWBD "HDP -42A" 4000A BUS 480V- 30.3W -65 KAIC 42 -1A 42 -2A XFR -42A HVS -42A 3000 KVA 600A, 27KV AA 80'C MIN. 6% IMP. 110KV BIL 26.4KV- 480/277V 250^ 3P 0 )T T T T PT T T 3P 0)3P.) P /3P 013 )3P /3P CENTRAL PLANT SUITE #1 SUITE #2 SUITE #3 3RD FLOOR 60AT OAT N5OAT 00AT 900AT 3P 3P . /3P .)3P 0)3P 150AT 150AT OAT j�OAT d 7OAT 3P 3P �13P a /3P 0)3P AHU -42A2 AHU -42M RF -42A3 XFR- 42A -H1 1 45KVA 480/277V I1 RF -42A1 RF -42A2 PNL 42A -H1 480/277 100A MCB 0I A Y 50AT 3P 1 4000AT `__.J 100KAIC 4" 1 L 1 1 4000AT5 I IQ 30STAJ1 ALT #1 AUTOMATIC TRANSFER • )1200AT )1200AT XFR- 42A -L1 30KVA 480V TO 208/120V PNL 42A -L1 208/120 100A MCB 225 KVA PDC 42 -A1.1 MBP -42 -A1 MAINT. BYPASS NC PANEL )1200AT 1200A, 480V 30 -3W 350 350 350 ,350 0 4003 ) 0) o) 1200AT NO 50 A1.1 A1.2 A1.3 A1.4 A1.5 4003 50 4000AT O) <0 350 225 KVA PDC 42 -A1.2 225 KVA PDC 42 -A1.3 uAw. 225 KVA PDC 42 -A1.4 225 KVA PDC 42 -A1.5 MBP -42 -A2 MAINT. BYPASS NC PANEL )1200AT 1200AT ) 1 i 1200A, 480VQ © NO I 1 I1350 11350 1350 �1550I 1350 1350 ;3501 A2.1 /42.2 A2.3 0A2.4 A2.5 I/ I/ l w 350AT ') 350AT C 225 KVA PDC 42 -A2.1 wtf.. C 5003 225 KVA PDC 42 -A2.4 350AT O) DIST. SWBD "HDP -42B" 4000A BUS 480V- 30 -3W-65 KAIC E5.11 E5.13 3000A BUSWAY E5.12 FUTURE ALTERNATE 1 K K 4000AT 911A ■ 1 90A ■ I 1 100KAIC,Z,� -- 1 T _L I 'I I I al 4000AT >1 1 ( 3000A )1 I I 1 ALT #1 I S 42 -1B 42 -2B XFR -42B HVS -42B 3000 KVA 600A, 27KV M 80'C MIN. 6% IMP. 110KV BIL 26.4KV- 480/277V 2500AT, 3P 900AT 150AT BOAT 3P 0)3P .)3P . ill 3P OAT OAT OAT 10DAT GOAT )3P 3P „ 3P )3P )3P 60AT 800AT 3P 0)3P p 3P CHP -42B1 CHP -42B2 CH-4282 :ry CH -42B1 150AT 150AT 0AT 3P ..)3P ., 3P /, AHU -42B2 RF -42B3 AHU -4281 OAT 3P A AUTOMATIC TRANSFER 4000AT ) L. 2500 KW -1 3125 KVA GENERATOR "GEN 42B" IY 1�- 40003 RE-42B1 70AT 50AT )3P 3P XFR-428-H1 45KVA 480/277V rv7 1' RF -4282 PNL 42B -H1 480/277 100A MCB 0 0 XFR - 42B -L1 30KVA 480V TO 208/120V PNL 42B -L1 208/120 100A MCB )1200AT )1200AT 0 zL? 0 0 MBP -42 -B1 MAINT. BYPASS NC PANEL 1200AT 1200AT 30-3W 1200A, 480V © 1, NO q I i j 1800 1800 j\ 0 ii00 1800 I 1800 1800 17800 BC1 �CB1 BD1 '31 I 1' STS 42 BC1 m E0 0 N STS 42 BD1 225 KVA PDC 42 -BC .2 225 KVA PDC 42 -BC1.1 225 KVA PDC 42- BC1.3. wtn. 225 KVA PDC 42 -BD1.2 225 KVA PDC 42 -BD1.1 1200 1200 0 I�IYtlY )1200AT 0 MBP -42 -B2 MAINT. BYPASS NC PANEL 1200AT 1 1200A, 4801 1 30 -3W m U I 800 1800 S00 BC2 CB2 BD2 0- a STS 42 BC2 225 KVA PDC 42 -BC2.2 225 KVA PDC 42 -801.3 N 03 U 03 C.4 STS 42 BD2 12003 350AT , 350AT ) 350AT ) 1200AT_) 1 NO © I 1800 11800 Qpp00 800 ITN] DB2 1) I) I) 03 03 11 XFR- 42BD2 -L1 75KVA 480V TO C 120/208V C 225 KVA PDC ww 225 KVA PDC 42 -802.3 001(2, 225 KVA PDC 42 -802.1 225 KVA PDC 42 -802.3 PNL 4280 -L1 120/208V 225A CENTRAL PLANT CE SUREA7 SUITE #2 REVIEWED FOIE COMPLIANCE WITH NFPA 70 - NEC FEB 17 2011 225 KVA P 42 _BD2. C City of Tukwila BUILDING DIVISION SUITE #3 RECEIVED FEB 04 2011 PERMIT CENTER 3RD FLOOR E5.12 E5.13 62 z 0 ONSULTANT w 0 J 0 z I U w F- od 0 1- U w J w NTERGATE EAST CAMPUS TM 603376 m O N N O H- 0 W 0 CC 0 ISSUED /REVISED DATE PROGRESS DRAWING 4/29/10 REVIEW SET } „'' 1/14/.11 PERMIT SET urn 1/28/11 PHASE 42 ONE -LINE DIAGRAM E5.12 3 4 5 6 7 8 9 10 E5.11 E5.12 E5.13 3000A BUSWAY DIST. SWBD "HDP -42C" 4000A BUS 480V- 310 -3W-85 KAIC I)P T )3P 150AT 0180AT I.p PT CENTRAL PLANT SUITE #1 SURE ,p2 FLAG NOTES: I�OAT . 3P N2 OAT )3P IF—C1 OAT 3P EF -42C1 PROVIDE THIMBLES FOR DC CABLES NOT USED NOT USED NOT USED NOT USED PROVIDE STATUS NOTIFICATION OF BREAKER POSITION MONITOR AMPERAGE ONLY VIA ACL MONITORING BYPASS ISOLATION OPEN TRANSFER (3) OUTPUT BREAKERS 350A : PROVIDE FUNCTIONALITY FOR BMS TO MONITOR BREAKER STATUS PRf1VIfF 195A f1I ITPI IT RRFAKFR )3P T b) P T b) T 3P CRAC -42C3 CHP -42C2 CHP -42C1 800AT b..80OAT )3P 3P 0 CH-42C2 CH -42C1 :3.. :..v.;z 3.3...3::. ?? ::3 :: :n.:A::. 3333 ....::.3 42 -1C 42 -2C HVS -42C 600A, 27KV 110KV BIL 2500AT 3P 0 I)3P T 0)3P LI5OAT OAT /3P AHU -42C2 RF0 3 0 AHU -42C1 XFR -42C 3000 KVA AA 80.0 MIN. 6% IMP. 26.4KV- 480/277V 70AT )3P XFR - 42C —H1 4VA 4805K/277V rY�+ 11 RF -42C1 RF -42C2 PNL 42C —H1 480/277 100A MCB 50AT 3P A-�Y I )100AT 13P twss 1)1200AT 4000AT d 1001WC 4, I T L I4000AT_; v AUTOMATIC TRANSFER 40003 4000AT ) 10 - 4000A 2500 KW 3125 KVA GENERATOR "GEN 42C" IY STATIC SWITCH MBP -42 -C1 MAINT. BYPASS PANEL 1200A, 480V 30 -3W )1200AT )12NC 00AT ® 12 0AT N0Di J I AS00 18800 1800 1800 1800 80q CD1 DC1 I T 1 I XFR- 42A—L1 30KVA 480V TO 208/120V PNL 42C —L1 208/120 100A MCB ( STS 42 C11 225 KVA PDC 42 —CB1.3 .,un. 0 STS 42 CD1 225 KVA PDC 42 —CD1.1 U 225 KVA PDC 42 —CD1.2 C 225 INA PDC 42 —CD1.3 wlwi 120 • S�7 =1 1 )1200AT 1200 SWITCH ) MBP -42 -C2 MAW. • BYPASS NC PANEL 1200AT 1200A, 480V 1 30 -3W J,800 1800 B00 CB2 BC2 WOO STS 42 CB2 225 KVA PDC 42 —CB2.1 0 CD2 STS 42 CD2 12003 350AT ) 350AT 1200AT) NO T I I I 11300 00 1800 1800 118001 DC2 T L 1 1 U m 350AT 225 KVA PDC 42 —CB2.2 225 KVA PDC 42 -092.3 .wAA J 225 KVA PDC 42 -002.1 KVA PDC 42 —CD2.2 225 KVA PDC 42 -002.3 .�.w ?3,93(.;.4.11.1;'£ 3333 CH -42D1 TEMPORARLY FED TO C 3 3333. 3333. CENTRAL PLANT SURE #1 SUITE #2 REVIEWED .f i)H COMPLIANCE WITH NFPA70 - NEC FEB 17 2011 City of•Tukwila lILDING DIVISION SUITE #3 RECEIVEI FEB 04 2011 PERMIT CENTEE KEY PLAN 3R0 FLOOR w z Fourth Floor CONSULTANT: 1n 0 0 z I O T E O LCi O 0 co rn T N N CO O N N CO CD 00 N N N W ca a Z o. ca N TM 603376 w 0 J a. 1- 0 N ILO U) M M CO O N Lf) N O N 1- U 0 w 1Z ISSUED / REVISED DATE PROGRESS DRAWING 4/29/10 REVIEW SET 1/14/11 PERMIT SET 1/28/11 PHASE 42 ONE -LINE DIAGRAM E5.13