Loading...
HomeMy WebLinkAboutPermit EL11-0207 - VULCAN EMPVULCAN EMP 3314S116ST EL1 1 -0207 Parcel No.: Address: Tenant Name: City Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 -431 -2451 Web site: http: / /wwwci.tukwila.wa.us 1023049011 3314 S 116 ST TUKW VULCAN EMP ELECTRICAL PERMIT Permit Number: EL11 -0207 Issue Date: 04/05/2011 Permit Expires On: 10/02/2011 Owner: Name: Address: Contact Person: Name: Address: APOLLO HOLDINGS LLC 505 5TH AVE S #900 , SEATTLE WA 98104 JEFF LOZIER PO BOX 338 , KENT WA 98035 Contractor: Name: HOLMES ELECTRIC CO Address: PO BOX 179 , RENTON WA 98057 Contractor License No: HOLMEEC549BH Phone: 206 - 462 -9223 Phone: (425)255 -8666 Expiration Date: 10/31/2012 DESCRIPTION OF WORK: TENANT IMPROVEMENT. ADDING 200A 480V PANEL WITH 30KVA TRANSFORMER AND 100A 208V PANEL. MISCELLANEOUS LIGHTING, RECEPTACLES AND HVAC EQUIPMENT. Value of Electrical Work: NRES: $86,766.00 Fees Collected: $1,774.50 RES: $0.00 Type of Fire Protection: UNKNOWN Electrical Service Provided by: SEATTLE CITY LIGHT Permit Center Authorized Signature: National Electrical Code Edition: 2008 [JAL Date: 141 S I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authoriy i to sign and obtain this electrical permit and agree to the conditions on the back of this permit. Signature:` Date: Wds✓ )/ Print Name: e- v� �7>7 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -9/09 ELI 1-0207 Printed: 04 -05 -2011 • * *ELECTRICAL ** PERMIT CONDITIONS Permit No. EL11 -0207 1: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 2: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 3: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 4: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 5: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 6: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. doc: EL -9/09 E L 11 -0207 Printed: 04 -05 -2011 • CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www. ci. fukwila. wa. us ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: 3314 South 116th Street Tenant Name: EMP King Co Assessor's Tax No.: Suite Number: New Tenant: 0-30 1-1-- a0 I I Property Owners Name: Vulcan Mailing Address: 3314 South 116th Street Tukwila Floor: ❑ Yes m .. No WA 98168 Zip City State CONTACT PERSON — Who do we contact when your permit is ready to be issued Name: Jeff Lozier Mailing Address: PO Box 338 Day Telephone: (206) 462 -9223 Kent WA 98035 E -Mail Address: leff.lozier @holmes.com City State Fax Number: (253) 234 -2900 Zip ELECTRICAL CONTRACTOR INFORMATION Company Name: Jeff Lozier Mailing Address: PO Box 338 Contact Person: Jeff Lozier Kent WA 98035 City State Day Telephone: (206) 462 -9223 E -Mail Address: jeff.lozier @holmes.com Fax Number: (253) 234 -2900 Zip Contractor Registration Number: HOLMEEC549BH Expiration Date: 10/31/2012 Valuation of Project (contractor's bid price): $ 86,766 Scope of Work (please provide detailed information): Tenant Improvement. Adding 200A 480V panel with 30kVA trans- former and 100A 208V panel. Miscellaneous lighting, receptacles and HVAC equipment. Will service be altered? Type of Use: Storage m Yes ❑ No Adding more than 50 amps? m Yes ❑ No Type of work: ❑ New ❑ Addition ❑ Service Change ❑ Low Voltage ❑ Generator ❑ Fire Alarm Property Served by: ❑ Puget Sound Energy m Seattle City Light H: \Applications \Fonns - Applications Ou Line\2010 Applications \7 -2010 - Electrical Permit Application.doc bh Page 1 of 2 ❑ Remodel Tenant Improvement ❑ Telecommunication ❑ Temporary Service r • RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $152.85 (including an attached garage) ❑ Garages, pools, spas and outbuildings $81.90 ea ❑ Low voltage systems (alarm, furnace thermostat) $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $81.90 (no added/altered circuits) ❑ Service change with added/altered circuits $81.90 number of added circuits $11.55 ea ❑ Circuits added/altered without service change $54.60 (up to 5 circuits) ❑ Circuits added/altered without service change $54.60 (6 or more circuits) $7.65 ea ❑ Meter /mast repair $68.25 ❑ Low voltage systems $59.85 (alarm, furnace thermostat) MULTI- FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $63.00 ❑ Temporary service (generator) $78.75 ❑ Manufactured/mobile home service $84.00 (excluding garage or outbuilding) ❑ Carnivals $78.75 Number of concessions $10.50 ea PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: Print Name: 3-E FF L-47 Mailing Address: PO Box 338 IDate Application Accepted: (4` ` I Day Telephone: Kent City Date: 03/14/2011 (206) 462 -9223 State 98035 Zip Date Application Expires: Staff Initials: H:\Applications\Fonus- Applications On Linee2010 Applications \7 -2010 - Electrical Petmit Application.doc hh Page 2 of 2 • 0 C City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone : 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 1023049011 Address: 3314 S 116 ST TUKW Suite No: Applicant: EMP RECEIPT Permit Number: EL11 -0207 Status: PENDING Applied Date: 03/14/2011 Issue Date: Receipt No.: R11 -00483 Initials: User ID: WER 1655 Payment .Amount: $1,774.50 Payment Date: 03/14/2011 11:28 AM Balance: $0.00 Payee: HOLMES ELECTRIC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 055139 1,774.50 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.00 ELECTRICAL PLAN - NONRES 000.345.832.00.00 Total: $1,774.50 1,419.60 354.90 doc: Receiot -06 Printed: 03 -14 -2011 INSPEOTION RECORD Retain a copy with permit e217 4'..211t, INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: , VII 1. 0,A ri S-1141° Type of Inspection: /2 /0 Address: 3-P/if S. ii 3- Date Called: Special Instructions: Date Wanted: a.m. p.m. Requester: Phone No: XApproved per applicable codes. 0 Corrections required prior to approval. COMMENTS: 1 Inspector: 7iDate: rj REINSP CTION FEE REQUIRED. Prior to next inspection, fee must be paid at 300 Southcenter Blvd., Suite 100. Call to schedule reinspection. '77 • • • • .1. • • f' • :.•-• • '" -;re INSPECTION RECORD Retain a copy with permit' INSPECTION NO. DU7 P RMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3 Permit Inspection Request Line (206) 431-2451 Project: V ULCAr41 (IP Type of Inspection: 2/00 Address: 33v5./1105r- Date Called: Special Instructions: Date Wanted: 7/Z7 ap.. e; Requester: Phone No: ElApproved per applicable codes. El Corrections required prior to approval. COMMENTS: - ik1 t&h&M (QtAiisAiAr Date: 07/27 1 REINSPECTION FEE REQUIRE b. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Inspector: tirv 3 INSPECTION NO. INSPECTION RECORD Retain a copy with permit 640°7 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 7,7 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -367 Permit Inspftction Request Line (206) 431 -2451 Project: 1t lecsari j Type of Inspection: �� 3 Address: 3311 J_ /1! 5f Date Called: Special Instructions: Date Wanted: 701 a.m.. p 1 Requester: Phone No: Approved per applicable codes. aCorrections required prior to approval. COMMENTS: (A1644.5 AriNID Inspector: Date: to7/0 REINSPECTION FEE REQUIRED. Prior to next inspection; fee must be • : = paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspectiorr::. • r:taf INSPECTION NO. ..•17"'"'"*-V7-- t•. ■•• " ••• • • • ".6 • ' INSPECTION RECORD Retain a copy with permit 641-ou7 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 431-2451 Project: t juLtiej p Type of Inspection: 70‘02-. Address: 33 iii 5 la, r Date Called: Special Instructions: Date Wanted: 6/30 .m Requester: . . Phone No: 1%1 COMMENTS: Approved per applicable codes. • •• • , • . • ,.• , • ••••'..;:s 12 Corrections required prior to approval. • -- I-4041v Pm levy asc4) TIRA.444fildlic le a-4E0*J itro4Arat — eziPhir A449 1tthtJbmAI Inspector: Date:. / • / • REINSPECTION FEE REQUIRED. Prior to next inspection. fee must.be..: paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspeciion: INSPECTION NO. INSPECTION RECORD Retain a copy with permit t- oo7 PERMIT NO. 'CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 V-4.-(206) 431-367 Permit Inspection Request Line (206) 431-2451 Project:\I catisi L.4, D. Ut.. lel li Type of Inspection: 766, Address: 33 111 . .5r• /Me Date Called: Special Instructions: Date Wanted: Requester: Phone No: ElApproved per applicable codes. DCorrections required prior to approval. COMMENTS: ?), kL ei,d6\ „i fildfri "VA) Inspector: „fAikip.1 Date: 06/041 n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. PERMIT COY PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: EL11 -0207 PROJECT NAME: EMP SITE ADDRESS: 3314 S 116 ST X Original Plan Submittal Response to Incomplete Letter # DATE: 03 -14 -11 Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: [[ ,, din D 3 ' uuiIivision Public Works ❑ Fire Prevention Structural Planning Division n Permit Coordinator i DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete r74 Incomplete DUE DATE: 03-15-11 Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route Structural Review Required n No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: DUE DATE: 04 -12 -11 Not Approved (attach comments) n REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 Contractors or Tradespeople Pfer Friendly Page • Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company HOLMES ELECTRIC CO 2534794000 Po Box 338 Kent WA 98035 King Corporation UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 177003752 Active HOLMEEC549BH Electrical Contractor 1/8/1946 10/31/2012 General Unused Master Electrician INFORMATION License HILLME *973KR Name HILLMAN, ED Status Active Business Owner Information Name Role Effective Date Expiration Date HOLMES, JERAY A Agent 01/01/1980 Bond Amount HOLMES, MICHAEL J President 01/01/1980 52BSBFB9243 RICHARDS, MICHAEL W Secretary 01/01/1980 RICHARDS, EUGENE M 01/01/1980 10/15/2010 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 3 HARTFORD FIRE INS 52BSBFB9243 12/08/2008 Until Cancelled $4,000.0012/09/2008 2 AM CASUALTY 9239830 12/08/1984 Until Cancelled 02/09/2009 $4,000.0009/14/2008 Assignment of Savings Information No records found for the previous 6 year period Insurance Information No records found for the previous 6 year period Summons /Complaint Information Summons and Complaints are not filed with the department for this contractor type Warrant Information Warrants are not filed with the department for this contractor type Infractions /Citations Information Infraction / Citation Date RCW Code Type Status Violation Amount EREEB00495 10/8/2009 19.28.101 RCW ELECTRICAL CITATION Satisfied $250.00 https: // fortress .wa.gov /lni/bbip /Print.aspx 04/05/2011 w z ort �L 0940 6, m a_ i,. 600 AMP M.C.B. (2)3" EMT (4)350 KCMIL -20 GND L -6 100A MCB 120/208V 30 4W 1-1/4"C. W/ (4) #3, #8 GRND XMFR #3 30KVA 2 "C. W/ (4) #3/0, #6 GRND H -4 200A MLO 480/277V 30 4W ATS 800A 1 "C. 3#8,1#10 1"C. W/ (3) #8, 1 #10 GRND (2)2-1/2" EMT (4) 250KCMIL -- 10 GND 450AMP M.C.B. Lirnn Architecture Urban Design Interiors 801 Second Avenue, Suite 501 Seattle, Washington 98104 T 206 682 3460 F 206 343 9388 www.Imnarchitects.com 2 "C. 4- 3/0,1 #6 300KW GENERATOR MDP 600A M LO 480/277V 30 4W H -2 200A MLO 480/277V 30 4W 2"C. 4 -3/0, 1#6 100A MCB 120/208V 30 4W XMFR #1 30 KVA - 1,- 1/2 "C. 4#2,1#6 `IITS##1 200A 480/277V 30 4W 0\ - 2 "C. 4-3/0,1#6 H -2 200A MLO 480/277V 30 4W 1- 1/2 "C. 3 #2,1 #6- E XMFR #2 75 KVA T LI\ -- 2 "C. 4-3/0,1#6 (2)3" EMT (4)350 KCMIL -20 GND L-2 200A MCB 120/208V 30 4W 1-- 1/2 "C. 3#2,1#6 L -3 200A M LO 120/208V 30 4W L. -4 100A MLO 120/208V 10 4W SEPARATE PERMIT REQUIRED FOR riuthanket cl Elsoical numbing rikffin Fig City of Tukwila BUILDINGS DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. E DIAGRAM SCALE: NTS HOLMES ELECTRIC 600 Washington Ave. S. Kent, WA. 98032 Phone: 253.479.4000 Fax: 253.235.2900 www.hotmes.com H -3 200A M LO 480/277V 30 4W XMFR #3 30AA T --- 1-- 1/2 "C. 3#8,1#10 L -5 100A MCB 120/208V 30 4W 2 "C. 4 #2,1 #6 FIINE COPY Ponnft Not.sailidia01 Men review approval Is subject toens and tin. Approval of Consul N! docents not authorize shc violation of any adopted code or oxbow. Receipt of approved Field Copy and andlions ki acknowledged: BY- Date City Of 7kdorilla BUILDING DIVISICIO DRAWING INDEX E001 SYMBOLS & ABBREVIATIONS E002 LIGHTING SUMMARY AND PANEL SCHEDULES E201 POWER /HVAC PLAN E202 ROOF PLAN E301 LIGHTING PLAN REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC MAR 23 2011 ulk City of Tukwila BUILDING DIVISION Vulcan Apollo Warehouse EMPISFM Temporary Vault 3314 South 116th Street Tukwila, Washington Submittal PERMIT Documents SYMBOL LEGEND OUTLETS CIRCUITING i© AFCI ©GFCI GCE 20A FO 'mac Q 0O 10 ■M• 11 ■11 SINGLE RECEPTACLE STANDARD DUPLEX RECEPTACLE DOUBLE DUPLEX (QUAD) RECEPTACLE DEDICATED DUPLEX RECEPTACLE DEDICATED DOUBLE DUPLEX (QUAD) RECEPTACLE AFCI TYPE RECEPTACLE (F =FEED THRU) GFCI TYPE RECEPTACLE (F =FEED THRU) 20 AMP RATED DUPLEX SINGLE SPECIAL PURPOSE CEILING - MOUNTED DUPLEX RECEPTACLE WALL MOUNTED TELE /DATA /VIDEO SINGLE GANG WALL (MUDRING WITH PULL STRING U.N.0.) JUNCTION BOX WITH BLANK COVER WALL MOUNTED JUNCTION BOX FLOOR MOUNTED OUTLET BOX - DUPLEX, DOUBLE DUPLEX, SPECIAL RECEPTACLE, ETC. POWER POLE \ WIRING CONCEALED IN FLOOR OR UNDERGRND. NO. OF CONDUCTORS BRANCH CIRCUIT HOME RUN GROUNDING ELECTRODE CIRCUIT CONTINUATION GROUND CONDUCTOR, ISOLATED GROUND CONDUCTOR CIRCUIT TURN UP CIRCUIT TURN DOWN LIGHTING OUTLETS SWITCH OUTLETS SINGLE -POLE (a= FIXTURE) DOUBLE -POLE THREE -WAY FOUR -WAY 200 $ 300 M D SINGLE LEVEL OCCUPANCY SENSOR (WATT STOPPER WI -200 OR EQUAL) DUAL LEVEL OCCUPANCY SENSOR (WATT STOPPER WI -300 OR EQUAL) MOTOR RATED W /OVER LOADS DIMMER LOW VOLTAGE OVERRIDE SWITCH FOR LIGHTING ZONE CONTROL. SEE ZONAL SWITCHING PLAN. OCCUPANCY SENSOR SWITCH PAN ELBOARDS, SWITCHES & EQUIPMENT LCP ❑J NAS ®J 30AS 30AF zJ I'1 ATS ME 480Y/277V CIRCUIT BREAKER PANEL 208Y/120V CIRCUIT BREAKER PANEL LIGHTING CONTROL PANEL SWITCHBOARD OR MOTOR CONTROL CENTER DISCONNECT SWITCH (NON- FUSED) FUSED DISCONNECT SWITCH (WITH FUSE SIZE) MAGNETIC MOTOR STARTER COMB. STARTER & DISCONNECT SWITCH EQUIPMENT CONNECTION TRANSFORMER AUTOMATIC TRANSFER SWITCH SEPERATELY ENCLOSED CIRCUIT BREAKER GROUND BAR 0 IO D RECESSED FIXTURE SURFACE WALL MOUNTED RECESSED WALL WASH FIXTURE SURFACE OR PENDANT SURFACE OR PENDANT FLUORESCENT RECESSED 2' x 4' FLUORESCENT RECESSED 2' x 2 FLUORESCENT FLUORESCENT OPEN STRIP EGRESS BATTERY PACK CEILING MOUNTED EXIT /EGRESS WALL MOUNTED EXIT /EGRESS CEILING MOUNTED EXIT LIGHT WITH BATTERY PACK (ARROWS INDICATE DIRECTION, SHADING INDICATES NUMBER OF FACES) TRACK LIGHT FLUORESCENT OPEN STRIP WITH ON NIGHT LIGHT CIRCUIT • RECESSED FIXTURE ON NIGHT LIGHT CIRCUIT I UNDERCOUNTER FLUORESCENT WALL MOUNT FIXTURE FIXTURE TYPE COMMUNICATIONS SYMBOLS y K4 VGA CABLE (VIDEO) CCTV OVERHEAD PROJECTOR MICROPHONE CEILING MOUNTED SPEAKER WALL MOUNTED SPEAKER ABBREVIATIONS ADDITIONAL SYMBOLS LEI HORN STROBE FA LIGHT STROBE HEAT DETECTOR CARD READER OUTLET REFERENCES MECH EQUIPMENT (SEE MECH PLANS) EMERGENCY POWER OFF (EPO) SHUNT TRIP OCCUPANCY SENSOR POWER PACK PHOTO CELL FIRE ALARM PULL STATION CABLE TRAY j// DEMO HATCHING 30 SHORT CIRCUIT CURRENT ISSC> RRENT AVAILABLE Revisions No. Date By Description Drawn Checked LMN Proj No Date M.SWANSON J.LOZIER 2274 03.08.11 AF AFF AFCI AIC AL AS C CKT C.O. CU DED EC E FBO FSD G GFCI AMP FUSE ABOVE FINISHED /RAISED FLOOR ARC FAULT CIRCUIT INTERRUPTER AMPS INTER. CAP. ALUMINUM AMP SWITCH CEILING CIRCUIT CONDUIT ONLY COPPER DEDICATED ELECTRICAL CONTRACTOR EXISTING FURNISHED BY OTHERS (INSTALLED BY EC) FIRE SMOKE DAMPER GROUND GROUND FAULT CIRCUIT INTERRUPTER Sheet Title ISSC AMPERES SHORT LCP MC MCA MD NIC LIGHTING CONTROL PANEL MECHANICAL CONTRACTOR MINIMUM CIRCUIT AMPACITY MOTORIZED DAMPER NOT IN CONTRACT NEMA NATIONAL ELECTRICAL MANUFACTURING ASSOCIATION NF NON -FUSED NL NIGHT LIGHT N1 NEMA 1 RATED N3R NEMA 3R RATED PBO PROVIDED BY OTHERS (INSTALLED BY OTHERS) SCCA SHORT CIRCUIT CURRENT AVAILABLE SMR SURFACE METAL RACEWAY TMGB TELEPHONE MAIN GROUND BUSBAR TYP TYPICAL UNO UNLESS NOTED OTHERWISE WP WEATHER PROOF RECEIVED MAR 14 2011 IT CENTER Sheet Number £L11LOZO7 E001 SYMBOLS & ABBREVIATIONS Interior Lighting Summary G-INT 2006 Washington State Nonresidential Energy Code Compliance Forms. Revised July 2007 Project Info Project Address VULCAN APOLLO WAREHOUSE Date 3/10/2011 3314 SOUTH 116TH ST. For Building Department Use TUKWILA, WA Applicant Name: HOLMES ELECTRIC Applicant Address: 600 WASHINGTON AVE S. Applicant Phone: KENT, WA. 98032 1594.4 Project Description ❑ New Building ❑ Addition 4 Alteration ❑ Plans Included requirements. Refer to WSEC Section 1513 for controls and commissioning Compliance Option 0 Prescriptive ® Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting ❑ Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Maximum Allowed Lighting Wattage Location (floor /room no.) Occupancy Description Allowed Watts per ft2 ** Area in ft2 Allowed x Area EXTERIOR WAREHOUSE STORAGE 0.58 2749.0 1594.4 RM 201,202,204 VAULT 0.50 9867.0 4933.5 VAULT (C) T8 4' WRAPAROUND - 2 LAMPS 45 64.0 2880.0 ** From Table 15 -1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts 6527.9 Proposed Lighting Wattage Location (floor /room no.) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed EXTERIOR (A) COMPACT FLUOR. WALL PACK EGRESS -• 1 LAMP 1 48.0 48.0 RM 201,202,204 (B) T8 - FLUORESCENT HIGH BAY - 6 LAMPS 8 192.0 1536.0 VAULT (C) T8 4' WRAPAROUND - 2 LAMPS 45 64.0 2880.0 VAULT (E) T8 4' STRIP FIXTURE - 2 LAMPS 16 64.0 1024.0 40/3 EXIT 4 10.8 43.2 7.2 - - 7.2 - - 7.2 - - 7.2 - LIGHTING 1.6 20/1 LIGHTING VAULT 3.9 20/1 Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts 5531.2 Architecture Urban Design Interiors Second Avenue, Suite 501 Seattle, Washington 98104 T 206 682 3460 F 206 343 9388 www.lmnarchitects.com HOLM ES ELECTRIC 600 Washington Ave. S. Kent, WA. 98032 Phone: 253.479.4000 Fax: 253.235.2900 www.hodmes.com HOLMES ELECTRIC PANELBOARD SCHEDULE PROJECT: EMP TEMPORARY VAULT DATE: 10 -Mar -11 PANEL: H-4 SECTION: LOCATION: AMPS: 200 X MAIN LUG ONLY ISO GROUND BUS VOLTS: 277/480 MAIN CIRCUIT BREAKER BONDED GROUND BUS PHASE: 3 MAIN FUSE FEED THROUGH WIRE: FLUSH MOUNTED X TOP FEED A.I.C.: X SURFACE MOUNTED BOTTOM FEED CKT LOAD BRK BRK LOAD CKT NO. CIRCUIT NAME KVA A/PH A/PH KVA CIRCUIT NAME NO. LOAD KVA 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 EQUIP: CU -1 3.2 30/3 A B C A B C A B C A B C A B C A B C A B C 20/3 3.2 EQUIP: CU -2 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 - 3.2 - - 3.2 - - 3.2 - - 3.2 - EQUP: AH -1 7.2 40/3 40/3 7.2 AH -2 - 7.2 - - 7.2 - - 7.2 - - 7.2 - LIGHTING 1.6 20/1 LIGHTING VAULT 3.9 20/1 PHASE A LOAD (kVA) : 16.0 PHASE B LOAD (kVA) : 18.3 48.7 TOTAL LOAD (kVA) SEC 1 PHASE C LOAD (kVA) : 14.4 101.5 CONNECTED (AMP) SEC 1 PHASE A CONNECTED (AMP) : 57.9 50.1 DEMAND (kVA) PHASE B CONNECTED (AMP) : 66.1 104.4 DEMAND (AMP) PHASE C CONNECTED (AMP) : 52.0 CONNECTED LOAD RECEPT: 0.0 LIGHTING: 5.5 MOTOR: 0.0 HEATING: 43.2 COOLING: 0.0 EQUIPMENT: 0.0 DEMAND LOAD RECEPT:(100% 1ST 10k) RECEPT:(50% REM) LIGHTING:(125 %) MOTOR:(100 %) MOTOR:(25% LARGEST) HEATING: (100% HTG>CLG) COOLING:(100% CLG >HTG) EQUIPMENT:(100 %) TOTAL: 0.0 0.0 6.9 0.0 0.0 43.2 0.0 0.0 TOTAL: 48.7 50.1 Vulcan Apollo Warehouse EMP /SFM Temporary Vault 3314 South 116th Street Tukwila, Washington Submittal PERMIT Documents HOLMES ELECTRIC PROJECT: EMP TEMPORARY VAULT PANEL: L-6 LOCATION: AMPS: 100 VOLTS: 208Y/120 PHASE: 3 WIRE: A.I.C.: CKT NO. CIRCUIT NAME LOAD KVA PANELBOARD SCHEDULE DATE: 10- Mar -11 SECTION: MAIN LUG ONLY ISO GROUND BUS X MAIN CIRCUIT BREAKER BONDED GROUND BUS MAIN FUSE FEED THROUGH FLUSH MOUNTED X TOP FEED X SURFACE MOUNTED BOTTOM FEED BRK BRK LOAD CKT A/PH A/PH KVA CIRCUIT NAME NO. 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 RECEPT: ROOF TOP 0.2 20/1 A B C A B C A B C A B C A B C A B C A B C 30/2 2.6 EQUIP: HP -1 & FC -1 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 RECEPT: CONY RECEPTS 1.4 20/1 - 2.6 - RECEPT: WORKSTATION 1.4 20/1 0.1 EF -1 PHASE A LOAD (kVA) : 2.8 PHASE B LOAD (kVA) : 4.0 PHASE C LOAD (kVA) : 1.5 PHASE A CONNECTED (AMP) : 23.2 PHASE B CONNECTED (AMP) : 33.7 PHASE C CONNECTED (AMP) : 12.8 8.4 TOTAL LOAD (kVA) SEC 1 23.2 CONNECTED (AMP) SEC 1 8.4 DEMAND (kVA) 23.2 DEMAND (AMP) CONNECTED LOAD RECEPT: LIGHTING: MOTOR: HEATING: COOLING: EQUIPMENT: 3.1 0.0 0.0 5.2 0.0 0.1 DEMAND LOAD RECEPT:(100% 1ST 10k) RECEPT:(50% REM) LIGHTING:(125 %) MOTOR:(100 %) MOTOR:(25% LARGEST) HEATING:(100% HTG>CLG) COOLING:(100% CLG >HTG) EQUIPMENT:(100 %) TOTAL: 3.1 0.0 0.0 0.0 0.0 5.2 0.0 0.1 TOTAL: 8.4 8.4 Revisions No. Date By Description Drawn Checked LMN Proj No Date M.SWANSON J.LOZIER 2274 03.08.11 REVIEWEU .FOi COMPLIANCE WITH NFPA 70-NEC MAR 2 3 2011 - C ty o • kw1Ia BUILDING DIVISION Sheet Title LIGHTING SUMMARY AND PANEL SCHEDULES RECE vED MAR 1.4 2011 PERMIT CENTER Sheet Number E002 w 2 69 w W Z en o L- o.mu_ I SWITCH LOCATED AT TOP OF LADDER AH -2 480V, 30 26FLA 35AF 60AS U1 H- 4/8,10,12 LIGHT FIXTURES ABOVE UNITS 35AF 60AS 480V, 30 26FLA 13 H- 4/7,9,11 r_ �.J L6 -1 3� EF -1 120V, 10 L -6/6 I Lt- R L -6/2,4 TO HP -1 208V, 10, 2 PNL 'H -4' UH -2 120V, 1 L -6/6 30 KVA XFMR MOUNT ON WALL AT 10' AFF. / \ D i1 L -6/6 UH -1 120V, 10 REVIEWED FOR COMPLIANCE NECK MAR 2 3 211...... Lmn Architecture Urban Design Interiors 801 Second Avenue, Suite 501 Seattle, Washington 98104 T 206 682 3460 F 206 343 9388 www.lmnarchitects.com NW HOLMES ELECTRIC 600 Washington Ave. S. Kent, WA. 98032 Phone: 253.479.4000 Fax: 253.235.2900 www.holmes.com Vulcan Apollo Warehouse EMP /SFM Temporary Vault 3314 South 116th Street Tukwila, Washington Submittal PERMIT Documents Revisions No. Date By Description Drawn Checked LMN Proj No Date M.SWANSON J.LOZIER 2274 03.08.11 Sheet Title I —o cvu laa BUILDING DIVISION MDP RECEIVED MAR 14 2011 PERMIT CENTER Sheet Number E.L114)10*-7 E201 POWER/HVAC PLAN w W 0).Z� o� 69. 69 ER mc ami% CU -2 480V, 30 11.7FLA 30AS CU -1 480V, 30 11.7FLA GFI WP H- 4/2,4,6 20AF 30AS--- H - =-4/ 1-,3 -,5 L -6/1 E_ I i S r=) _....FEN AN _L. HP -1 208V, 10 25A MCA 40AF 60AS L -6/2,4 m n Architecture Urban Design Interiors 801 Second Avenue, Suite 501 Seattle, Washington 98104 T 206 682 3460 F 206 343 9388 www.Imnarchitects.com riHOLMES ELECTRIC 600 Washington Ave. S. Kent, WA. 98032 Phone: 253.479.4000 Fax: 253.235.2900 www.hoimes.com Vulcan Apollo Warehouse EMP /SFM Temporary Vault 3314 South 116th Street Tukwila, Washington L Submittal PERMIT Documents Revisions No. Date By Description Drawn Checked LMN Proj No Date M.SWANSON J.LOZIER 2274 03.08.11 Sheet Title REVIEWED FOR COMPLIANCE WITH NFPA70 -NEC MAR 2 3 2011 City of Tukwila BUILDING DIVISION RECEIVED MAR 14 2011 PERMIT CENTER Sheet Number EL1\ 0107 E202 ROOF PLAN w LU 69. LLI re —I Q J to 69. a m'u VAULT LIGHTING PLAN W N E SCALE: 1 /8" = 1' -0" LIGHTING FIXTURE SCHEDULE FIXTURE ID FIXTURE DESCRIPTION MOUNTING INFOMATION LAMP # VA OCOMPACT FLUORESCENT EXTERIOR EGRESS WALL PACK W /BATTERY PACK DAY —BRITE WLI42CCU— LPBDL940 —E 1 50 O FLUORESCENT HI —BAY GVEX— U— BP —WB —WH 6 192 0 4' WRAPAROUND COLUMBIA AWN4232EB8LHUNV 2 64 © 4' STRIP FIXTURE W /CAGE COLUMBIA CS4- 232— EU —CSWG4 2 64 is LED EXIT FBD- 632 -UNV- 1/42 —EBH LED 11 Lmr-i Architecture Urban Design Interiors 801 Second Avenue, Suite 501 Seattle, Washington 98104 T 206 682 3460 F 206 343 9388 www.Imnarchitects.com pm HOLM ES WAIII ELECTRIC 600 Washington Ave. S. Kent, WA. 98032 Phone: 253.479.4000 Fax: 253.235.2900 www.hoimes.com ,_I ;.F (.,fir [I P.•E) ' I'd i v1,,, 10R F . Vic, AR A 13 Vulcan Apollo Warehouse EMP /SFM Temporary Vault 3314 South 116th Street Tukwila, Washington UPPER AREA LIGHTING PLA\ SCALE: 1/8" = 1' -0" Submittal PERMIT Documents Revisions No. Date By Description Drawn Checked LMN Proj No Date M.SWANSON J.LOZIER 2274 03.08.11 Sheet Title REVIEWED $)H COMPLIANCE WITH NFPA70 MAR 23 2011 City &Tukwila BUILDING DIVISION L.. X `�.:�.L.I N(.; ti CI.- BAY f'.E::.Pr1(07ED f,N(: C r -, TED [:::X `,ING DRAFT ro f;'I:..Iv1AlN r(.) ICI MAIN RECEIVED MAR 14 2011 PERMIT CENTER RI NI K M Sheet Number L1tO 207 LIGHTING PLAN E301