HomeMy WebLinkAboutPermit EL11-0316 - WESTFIELD SOUTHCENTER MALL - DISNEY STOREDISNEY STORE 536 SOUTHCENTER MALL EL1 1 -0316 C"f Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite # 100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 9202470010 Address: 536 SOUTHCENTER MALL TUKW Tenant Name: DISNEY STORE ELECTRICAL PERMIT Permit Number: EL11 -0316 Issue Date: 06/09/2011 Permit Expires On: 12/06/2011 Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA 92013 Contact Person: Name: STARR DE LA CRUZ Phone: 310 606 -2078 X 110 Address: 2413 PACIFIC COAST HY #202 , LOMITA CA 90717 Contractor: Name: SIGN -TECH ELECTRIC LLC Address: 5113 PACIFIC HWY E, SUITE 12 , 98424 Contractor License No: SIGNTEL988BG Phone: 253 - 922 -2146 Expiration Date: 01/07/2012 DESCRIPTION OF WORK: NEW LIGHTING FIXTURES THROUGHOUT Value of Electrical Work: NRES: $20,000.00 RES: $0.00 Type of Fire Protection: SPRINKLERS /AFA Electrical Service Provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: Fees Collected: $608.63 National Electrical Code Edition: 2008 Date: CU (MI I hereby certify that I have read and x ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complie with whether specified herein or not. The granting of this permit does not pr sk a to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to si and obtain this electrical permit and agree to the conditions on the back of this permit. Signature: Print Name: Date: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -9/09 EL11 -0316 Printed: 06 -09 -2011 4 p PERMIT CONDITIONS Permit No. EL11 -0316 * *ELECTRICAL ** 1: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 2: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 3: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 4: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 5: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 6: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. doc: EL -9/09 E L11 -0316 Printed: 06 -09 -2011 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 ht tp:f/www. ci. t ukwila. wa. us Electrical Permit Na eLi ntLa Project No. (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: S3 L Soaelavii 1 -Q_ Tenant Name: Di tnt y Stare LlCProperty Owners Name: J P at Mailing Address: a OD SUTAtacP 4-v- -- King Co Assessor's Tax No.: 60-0 941 L --0 10 Suite Number. S9 2 Floor. New Tenant: E- Yes ❑ ..No seed* (AA 9e ir? City State 7�p CONTACT PERSON - Who do we contact when your permit is ready to be issued Name: Mailing Address: E -Mail Address: (41eAMINCitke e 'C 0Y' Day Telephone: 20 City State Fax Number: 3t 0 --LOO (P' i;k 01/ 1 O 0 ELECTRICAL CONTRACTOR INFORMATION Company Name: Mailing Address: ctn. Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: State Zap Valuation of Project (contractor's bid price): $ c" ° L °-() 6 Scope of Work (please provide detailed information): ,Ld l/ jel e)5 1 k1.11 J vt-+J Will service be altered? 1 Yes ❑ No Type of Use: Type of work: New ❑ Addition ❑ Low Voltage ❑ Generator Property Served by: Puget Sound Energy ❑ Seattle City Light Adding more than 50 amps? ❑ Yes No Service Change Fire Alarm It wpptieauons Forms- App!tca:mns oa tanel20tO AppItcatmns17.I010 - Electrum! P ront Apphcan n doe hn Page 1 of 2 ❑ Remodel ❑ Telecommunication * Tenant improvement ❑ Temporary Service RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $152.85 (including an attached garage) ❑ Garages, pools, spas and outbuildings $81.90 ea ❑ Low voltage systems (alarm. furnace thermostat) $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or aheration $81.90 (no added/altered circuits) ❑ Service change with added/altered circuits $81.90 number of added circuits $11.55 ea ❑ Circuits added/altered without service change $54.60 (up to 5 circuits) ❑ Circuits added/altered without service change $54.60 (6 or more circuits) $7.65 ea ❑ Meter /mast repair $68.25 ❑ Low voltage systems S59.85 (alarm, furnace thermostat) MULTI - FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $63.00 ❑ Temporary service (generator) 578.75 ❑ Manufactured/mobile home service $84.00 (excluding garage or outbuilding) ❑ Carnivals $78.75 Number of concessions $10.50 ea PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fec schedules. Expiration of Plan Review — Applications for which no pennit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall he requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON. AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CO: • y OR: Signature: Print Name: Si: ICI �( n� Mailing Address: `7 tS Date Application Accepted: Day Telephone: City Date: IcIti 014 o1 Date Application Expires: LQ 101 I f' Staff Initials: H Wpplttmtarotrom s- Applttauons On Lunn2010 Appbcaeonst7.1010- Eleancal Pemot Appbmnon.c Page 2 of 2 r � City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov RECEIPT Parcel No.: 9202470010 Permit Number: EL11 -0316 Address: 536 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 04/07/2011 Applicant: DISNEY STORE Issue Date: Receipt No.: Initials: User ID: R11 -01172 JEM 1165 Payment Amount: $499.50 Payment Date: 06/09/2011 12:01 PM Balance: $0.00 Payee: SIGN -TECH ELECTRIC LLC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 6153 499.50 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.00 499.50 Total: $499.50 doc: Receipt-06 Printed: 06 -09 -2011 Cit,of Tukwila. • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206-431-3665 Web site: http: //www. ci. tukw ila. wa. us SET RECEIPT RECEIPT NO: R11 -00668 Initials: JEM Payment Date: 04/07/2011 User ID: 1165 Total Payment: 942.95 Payee: PERMITS DIRECT SET ID: S000001491 SET NAME: Tmp set/Initialized Activities SET TRANSACTIONS: Set Member D11 -085 EL11 -0316 M11 -043 PG11 -053 TOTAL: Amount 709.35 109.13 83.26 41.21 709.35 TRANSACTION LIST: Type Method Description Amount Payment Check 1987 942.95 TOTAL: 942.95 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES 000.345.832.00.0 PLAN CHECK - NONRES 000.345.830 109.13 833.82 TOTAL: 942.95 INSPECTION NO. INSPECTION RECORD Retain a copy with permit ERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 p- (206) 431 -3 Permit Inspection Request Line (206) 431 -2451 Project: 3 5A/e7 'fa kr' Type of Inspection: zoo Address: 5- fD q ' �✓ Date Called: Special Instructions: Date Wanted:. .m. .m Requester: Phone No: . Approved per applicable codes. D Corrections required prior to approval. OMMENTS: 0 Inspector: rate: • t "--1 REINSPECTIO FEE REQUIRE . Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION - RECORD Retain a copy with permit RMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 (206) 431 -36 Permit Inspection Request Line (206) 431 -2451 Project: 7\e Qt Type of Inspection: 0` K. r 6r 0-Ite w Address. 1 � 5% 1/411t/ Date Called: . J ploworkkif tics rtn1 i r =�. Special Instructions: - 4' QTq, Pkpift, ./AGk } Date Wanted:. • .m Requester: . Phone No: • JApproved per applicable codes. Corrections required prior to approval. COMMENTS: Qt 0` K. r 6r 0-Ite w ... 600 eP6 or Tom /IA a. / agiAleor ' r14-t u Aettrift. ac � . J ploworkkif tics rtn1 i - iA4tsr t/ Q L Al kNib 61.441P o4 &f -QA6 ca._ 150.6eviag, f - 4' QTq, Pkpift, ./AGk } - 1 Qtor NMAI i Th tac7k1CA -t-- ID lbe vUiLe9 Inspector: 'Date: or ri REINSPECTION FEE REQUIRED. rior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspectioh. • INSPECTION RECORD t Retain a copy with permit • INSPECTION NO. PERMIT NO. . • CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 ft,,„ (206) 431 -36 Permit Inspection Request Line (206) 431 -2451 Project: Y Sdv , Sri u Address: 53(0 1t1444, Special Instructions: Type of Inspection: Date Called: 7',03 Date Wanted: . Requester: Phone No: ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: " Colt 1 S,aQSVPaif h�l I1OAf l fa Inspector: ■A6Ortiise\ ri REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Date: 0g/ti I • INSPECTION RECORD Retain a copy with permit (ii7 • INSPECTION NO. P RMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd:, #100, Tukwila. WA 98188 V4 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Type of Inspection: Project: ti 5 Address: Special Instructions: Slut Date Called: DApproved per applicable codes. Date Wanted: . Requester: Phone No: 7oo3 6Corrections required prior to approval. 'COMMENTS: /, Date: 0 0q ❑ REINSPECTION FEE REQUIR D. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. N INSPECTION RECORD tt1 �{ , -olt Retain a copy with permit INSPEITION NO. P RMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 V-,,:. (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: D 5 Type of Inspection: 7063 Address: 534 Date Called: Special Instructions: Date Wanted: I 3 a.m Requester: Phone No: r Approved per applicable codes. Q Corrections required prior to approval. COMMENTS: o YA- mews �rr� ktnvuo ,„/ A ve ecici Inspector: Date: 01/13 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. TT--773.-z-kng.r1F; - INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 F..1". (206) 431-36 Permit Inspection Request Line (206) 431-2451 Project i) m Smvitte • I Type of Inspection: 71903 Address: 53‘,-- (riot, Date Called: Special Instructions: Date Wanted: 7/07 (Cri. 22 : Id 11 1 Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: P4- OK e4Iif40 4JI P4g(495 01-6a Adb g6nzol Inspector: Date:07107/11 n REINSPECTION FEEIREQUIRED. Prior to next inspection, fee mustbe .• paid at 6300 Southcepter Blvd.. Suite 100. Call to schedule reinspectioh. •;--„ INSPECTION RECORD': Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Permit oInspect on Request #100, Tukwila. Line (206) 431-2 511188 ice-- (206) 431 -36 ft i -o31b Project: IN Type of Inspection: 7003 `J° Address: 5-3 / Date Called: Special Instructions: Date Wanted: 0'7 .m: Requester: Phone No: ' Approved per applicable codes. El Corrections required prior to approval. COMMENTS: r it95 &Mai r?i CAD ksvok, PE'? tkulti Date: 06/17/11 41-76 FA1616\ n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Inspector: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Ilia. (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 (U1-o316 Project: � ��� ��� Type of Inspection: ?DO FottA of 'RI f) Address: 534 ''` `' Date Called: 04 erT Ft1T J(A5 Special Instructions: Date Wanted: p a Requester: fi.,9C Phone No: LIApproved per applicable codes. Corrections required prior to approval. COMMENTS: I — rtA401i rlif 6P i 4.4 FottA of 'RI f) - 'r 1(. t.. dt- J D 3 5 04 erT Ft1T J(A5 - etc, e c 4J% (2 i ce /, *PPtzr ,Jr r),1- Ia-" per 89e - hr` t`'Jtl I4 -v. !SEAL- - 05 Mb Pt -1 5x7_69 s <& fi.,9C Inspector: j4646j4612) REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Date: 064411 11 2009 Washington State gy Code Compliance Form for Nonresidenti • Multifamily Residential Project Summary PRJ -SUM 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised November 2010 Project Info Project Address Westfield Southcenter Date 5/18/2011 536 Southcenter Mall For Building Department Use Tukwila, WA Applicant Name: Disney Applicant Address: Applicant Phone: FILE COPY Permit No. - REVISION N0. -1 REVIEWED .FOR COMPLIANCE WITH NFPA 70 a NEC MAY 'A 12011 City of Tukwila BUILDING DIVISION CI OFETIVAI A MAY 232011 PERMIT CENTER DUI -0311v 2009 Washington State rgy Code Compliance Form for Nonresidenti . Multifamily Residential Interior Lighting Summary LTG -INT 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised November 2010 Project Info Project Address Westfield Southcenter Date 5/18/2011 536 Southcenter Mall For Building Department Use Tukwila, WA Applicant Name: Disney Applicant Address: Applicant Phone: Project Description TOILET ❑ Plans Included requirements. -' New Building ❑ Addition ❑ Alteration Refer to WSEC Section 1513 for controls and commissioning Compliance Option 0 Prescriptive 0 Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) 1.40 changed 1 No changes are being made to the lighting and space use not ❑ Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Maximum Allowed Lighting Wattage Location (floor plan /room #) Occupancy Description Allowed Watts per ft2** Gross interior Area in ft2 Allowed x Area SALES Retail Sales 1.33 4625 6151 TOILET Toilet 0.80 87 70 SALES Display Area 1.40 850 1190 " From Table 15 -1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts 7411 Proposed Lighting Wattage Location (floor plan /room #) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Sales AA01 - Recessed LED 9 27 243 Sales CCO1 - Cove Lighting 201 6 1206 Sales CC04 - Theater Wall Washer 6 40 240 Sales Chandelier 1 60 60 Sales Fx02 - Pattern Projector 2 150 300 Sales TNF / TFL - LED Track Head 236 14 3186 Sales THW - LED Track Head 10 28 280 Sales TLV - Theater Track Head 12 37 444 Sales F4 - Linear Flourescent 2 60 120 Sales F5 - Linear Flourescent 19 60 1140 Sales F6 - Fixture Light 2 8 16 Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts 7235 Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T -8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts /Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For line voltage track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. For low voltage track lighting list the transformer rated wattage. 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts /Fixture blank. 2009 Washington State rgy Code Compliance Form for Nonresidenti d Multifamily Residential Interior Lighting Summary (back) LTG -INT 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised November 2010 Prescriptive Spaces Occupancy: Q Warehouse or Parking Garage 0 Other Qualification Checklist Note: If occupancy type is "Other" and fixture answer is checked, the number of fixtures in the space is not limited by Code. Clearly indicate these spaces on plans. If not qualified, do LPA Calculations. Lighting Fixtures: (Section 1521) Check if 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted. 1. Fluorescent fixtures with a) 1 or 2 two lamps, b) reflector or louvers, c) 5 -60 watt T -1, T -2, T -4, T -5, T -8, or CFL lamps, and d) hard -wired electronic dimming ballasts. Screw -in CFL fixtures and tracking lighting do not qualify. 2. Metal Halide with a) reflector b) ceramic MH lamps < =150w c) electronic ballasts 3. LED lights. TABLE 15 -1 Unit Liahtinq Power Allowance (LPA Use' LPA` (W /ft`) Use' LPA` (W /ft`) Automotive facility 0.85 Office buildings, office /administrative areas in facilities of other use types (including but not limited to schools, hospitals, institutions, museums, banks, churches)5 0.91 Convention center 1.10 Parking garages 0.20 Courthouse 1.10 Penitentiary and other Group 1 -3 Occupancies 0.90 Cafeterias, fast food establishments5, restaurants /bars5 1.20 Police and fire stations 0.90 Dormitory 0.85 Post office 1.00 Dweling Units 1.00 Retail10, retail banking, mall concourses, wholesale stores (pallet rack shelving) 1.33 Exercise center 0.95 School buildings (Group E Occupancy only), school classrooms, day care centers 1.00 Gymnasia, assembly spaces 0.95 Theater, motion picture 0.97 Health care clinic 1.00 Theater, performing arts 1.25 Hospital, nursing homes, and other Group 1 -1 and 1 -2 Occupancies 1.20 Transportation 0.80 Hotel /motel 1.00 Warehouses 0.50 Laboratory spaces (all spaces not classified "laboratory" shall meet office and other appropriate categories) 1.62 Workshops 1.20 Laundries 1.20 Libraries 1.20 Plans Submitted for Common Areas Only' Manufacturing facility 1.20 Main floor building lobbies' (except mall concourses) 1.10 Museum 1.00 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.80 Footnotes for Table 15 -1 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by 2% per foot of ceiling height above 20 feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by 2% per foot of ceiling height above 12 feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by 2% per foot of ceiling height above 9 feet. 6) Reserved. 7) For conference rooms and offices less than 150ft2 with full height partitions, a Unit Lighting Power Allowance of 1.1 w /ft2 may be used. 8) Reserved. 9) For indoor sport tournament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is 2.60 W /ft2. 10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three - quarter- height partitions (transparent or opaque) and lighting for free - standing display where the lighting moves with the display are exempt. An additional lighting power allowance is allowed for merchandise display luminaires installed in retail sales areas that are specifically designed and directed to highlight merchandise. The following additional wattages apply: i. 0.6 watts per square foot of sales floor area not listed in items ii and iii below; ii. 1.4 watts per square foot of fumiture, clothing, cosmetics or artwork floor area; or iii. 2.5 watts per square foot of jewelry, crystal or china floor area. The specified floor area for items i, ii, or iii above, and the adjoining circulation paths shall be identified and specified on building plans. Calculate the additional power allowance by multiplying the above LPDs by the sales floor area for each department excluding major circulation paths. The total additional lighting power allowance is the sum of allowances for sales categories!, ii, or iii plus an additional 1,000 watts for each separate tenant larger than 250 square feet in area. The additional wattage is allowed only if the merchandise display luminaires comply with all of the following: (a) Located on ceiling- mounted track or directly on or recessed into the ceiling itself (not on the wall). (b) Adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). This additional lighting power is allowed only if the lighting is actually installed and automatically controlled, separately from the general lighting, to be turned off during nonbusiness hours. This additional power shall be used only for the specified luminaires and shall not be used for any other purpose. This additional lighting power is allowed only if the lighting is actually installed. 11) Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks. 2009 Washington Stat Exterior Lighting Summary rgy Code Compliance Form for Nonresidents d Multifamily Residential 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential LTG -EXT Revised November 2010 Project Info Proj Addres:westfield Southcenter Date 5/18/2011 536 Southcenter Mall Tukwila, WA Name: Disney Appl. Name Appl. Phone For Building Department Use Project Description ❑ New ❑ Addition ❑ Alteration ❑ Plans Included Refer to WSEC Section 1513 for controls and commissioning requirements. Lighting Zone (as specified by Jurisdiction) O Zone 1 Zone 2 O Zone 3 O Zone 4 Compliance Option O Lighting Power Allowance O Systems Analysis Building Grounds (luminaires > 100 Watts) ❑ Efficacy> 60 lumens/W Controlled by motion sensor ❑ Exemption (list) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting and space use not changed. ❑ Less than 60% of fixtures are new, installed wattage not increased, & space use not changed. Tradable Maximum Allowed Lighting Wattage Base Site Allowance: Tradable Surfaces Description Allowed Watts per ft2 or per If Area (ft`), perimeter (10 or # of items Allowed Watts x ft2 (or x If) Total Allowed Tradable Watts: Tradable Proposed Lighting Wattage (use mfgr listed maximum input wattage for luminaire.) Surface Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Area (ft2), perimeter (If) or # of items Allowed Watts x ft2 (or x If) Total proposed tradable watts may not exceed the sum of total allowed tradable watts plus Total Proposed Tradable Watts: the base site allowance. Any base site allowance not needed to make tradable watts comply can be applied to individual non - tradable categories. Non - Tradable Maximum Allowed Lighting Wattage Base Site Allowance Remaining: Fixture Description Non - Tradable Surfaces Description Allowed Watts per ft2 or per If Area (ft2), perimeter (If) or # of items Allowed Watts x ft2 (or x If) Non - Tradable Proposed Lighting Wattage Surface Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Non - tradable proposed watts may not exceed allowed watts for any individual surface unless the total excess watts for all non - tradable surfaces are less than the remaining site allowance. Total excess Non - Tradable watts: Site Allowance Balance: 2009 Washington Stat- rgy Code Compliance Form for Nonresident' • d Multifamily Residential Exterior Lighting Summary (back) 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential TABLE 15 -2B LIGHTING POWER DENSITIES FOR BUILDING EXTERIORS LTG -EXT Revised November 2010 Specific area description Zone 1 500 W Zone 2 600 W Zone 3 750 W Zone 4 1300 W Base site allowance' Tradable Surfaces 2 Uncovered Parking Parking lots and drives Areas 0.04 W /ft2 0.06 W /ft2 0.10 W /ft2 0.13 W/ft2 Building Grounds Walkways less than 10 ft wide 0.7 W /linear foot 0.7 W/ linear foot 0.8 W/ linear foot 1.0 W/ linear foot Walkways 10 ft wide or greater Plaza areas Special feature areas 0.14 W /ft2 0.14 W /ft2 0.16 W /ft2 0.2 W /ft2 Exterior Stairways 0.75 W /ft2 1.0 W /ft2 1.0 W /ft2 1.0 W /ft2 Pedestrian tunnel 0.15 W /ft2 0.15 W /ft2 0.2 W /ft2 0.3 W /ft2 Landscaping 0.04 W /ft2 0.05 W /ft2 0.05 W /ft2 0.05 W /ft2 Building Entrances and Exits Main entries 20 W /linear foot of door width 20 W /linear foot of door width 30 W /linear foot of door width 30 W /linear foot of door width Other doors 20 W /linear foot of door width 20 W /linear foot of door width 20 W /linear foot of door width 20 W /linear foot of door width Entry canopies 0.25 W /ft2 0.25 W /ft2 0.4 W /ft2 0.4 W /ft2 Sales Canopies Free standing and attached 0.6 W /ft2 0.6 W /ft2 0.8 W /ft2 1.0 W /ft2 Outdoor Sales Open areas3 0.25 W /ft 2 0.25 W /ft2 0.5 W /ft2 0.7 W /ft2 Street frontage for vehicle sales lots in addition to "open area'' allowance No Allowance 10 W /linear foot 10 W /linear foot 30 W /linear foot Non - Tradable Surfaces° Building Facades No Allowance 0.1 W /ft2 for each illuminated wall or surfaces 0.15 W /ft2 for each illuminated wall or surface6 0.2 W /ft2 for each illuminated wall or surface Automated teller machines and night depositories 270 W per locations 270 W per location8 270 W per locations 270 W per locations Entrances and gatehouse inspection stations at guarded facilities 0.75 W /fie of covered & uncovered area Loading areas for law enforcement, fire, ambulance and other emergency service vehicles 0.5 W /ft2 of covered & uncovered area Material handling and associated storage No Allowance No Allowance No Allowance 0.5 W /ft2 Drive -up Windows & Doors 400W per drive - through Parking near 24 -hour retail entrances 800 W per main entry FOOTNOTES FOR TABLE 15 -2B: 1. Base site allowance may be used in tradable or nontradable surfaces. 2. Lighting power densities for uncovered parking areas, building grounds, building entrances and exits, canopies and overhangs and outdoor sales areas may be traded. 3. Including vehicle sales lots. 4. Lighting power density calculations for the following applications can be used only for the specific application and cannot be traded between surfaces or with other exterior lighting. The following allowances are in addition to any allowance otherwise permitted in the "Tradable Surfaces" section of this table. 5. May alternately use 2.5 watts per linear foot for each wall or surface length. 6. May alternately use 3.75 watts per linear foot for each wall or surface length. 7. May alternately use 5 watts per linear foot for each wall or surface length. 8. An additional 90 watts is allowed per additional ATM location. 2009 Washington Stat Lighting Power Allowance Adjustments rgy Code Compliance Form for Nonresidents d Multifamily Residential 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential LTG -LPA Revised November 2010 Project Address Westfield Southcenter Date 5/18/2011 Use this form if you are claiming any ceiling height adjustments for your Lighting Power Allowances for in erior lighting. The Occupancy Description should agree with the Use listed on Code Table 15 -1. Identify the appropriate Ceiling Height Limit (9 feet, 12 feet or 20 feet) on which the adjustment is based. The Adjusted LPA is calculated from this number and from the Allowed Watts per ft2. Carry the Adjusted LPA to the corresponding "Allowed Watts per ft2" location on LTG -SUM. Adjusted Lighting Power Allowances (Interior) Location (floor plan /room #) Occupancy Description Allowed Watts per ft2** Ceiling Height for this room Ceiling Height limit for this exception** Adjusted LPA Watts per ft2 From Table 15 -1 based on exceptions listed in footnotes 2009 Washington Statergy Code Compliance Form for Nonresidentiy^wd Multifamily Residential Lighting, 2009 Washington Motor, and i ransformer Permit Plans-thecklist LTG -CHK State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised November 2010 Project Address Westfield Southcenter Date 5/18/2011 The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements in the 2009 Washington State Nonresidential Energy Code. Applicability (yes, no, n.a.) Code Section Component Information Required Location on Plans Building Department Notes LIGHTING CONTROLS (Section 1513) Yea 1513.1 Local control /access Schedule with type, indicate locations E2.0 Yea 1513.2 Area controls Maximum limit per switch E1.1 N.A. 1513.3 Daylight zone control Schedule with type and features, indicate locations N.A. vertical glazing Indicate vertical glazing on plans N.A. overhead glazing Indicate overhead glazing on plans Yea 1513.4 Display /exhib /special Indicate separate controls E1.1 N.A. 1513.5 Exterior shut -off Schedule with type and features, indicate location N.A. (a) timer w /backup Indicate location N.A. (b) photocell. Indicate location Yes 1513.6 Inter. auto shut -off Indicate location Yea 1513.6.1 (a) occup. sensors Schedule with type and locations E2.0 Yes 1513.6.2 (b) auto. switches Schedule with type and features (back -up, override capability); Indicate size of zone on plans E2.0 N.A. 1513.7 Hotel /motel controls Indicate location of room master controls Yea 1513.8 Commissioning Indicate requirements for lighting controls commissioning E1.1 EXIT SIGNS (Section 1514) Yes I 1514 IMax. watts 'Indicate watts for each exit sign 1E1.3 I LIGHTING POWER ALLOWANCE (Section 1530 -1532) Yes 1531 Interior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture E1.3 N.A. 1532 Exterior Lighting Summary Fomi Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture MOTORS (Section 1511) Yes I 1511 IElec motor efficiency IMECH -MOT or Equipment Schedule with hp, rpm, efficiency 11.12 . 0 I TRANSFORMERS (Section 1540) N.A. 1 1540 'Transformers 'Indicate size and efficiency 1 ' If no is circled for any question, provide explanation: • • LINA■E City of Tukwila - Plan Check Comments The Disney Store - Westfield Southcenter 536 Southcenter Mall, Space #592, Tukwila, WA 98188 Application #D11 -085 & #M11 -043 May 18, 2011 Dear Plan Reviewers, RECEIVE CITY OF TUKWILA IIAI.2 .3 2011 PERMIT CENTER The following are responses to the comments from the respective departments from The City of Tukwila. These corrections have been incorporated into our set as Revision 1 and dated 05.18.11 City of Tukwila Building Division. by Dave Larson Building - Permit #D11 -085 1. The occupant load of the retail space requires two exits. The rear exit goes through the stockroom. The following section applies, Section 1014.2 2009 IBC... please . revise exiting plan to comply with the code section above or provide another exit in a 'different location. • We have revised all of our plans to include an extra exit in the stockroom which will prevent all occupants inside the sales area to have to go through the stockroom to exit the store. Our exiting diagrams on sheet A0.2 have been revised to reflect this. 2. Emergency lighting per section 1006 IBC is required along the main egress paths that connect the front and back exits. I could not find plans that show emergency light fixtures aligned with the egress path. Your egress plan is on page A0.2 and it would be helpful if you showed emergency light fixtures on this plan. You will need enough to meet the intensity requirement (average 1 foot candle at floor level) along the main egress aisles. • We have taken your advice and revised our A0.2 to not only include our emergency track lighting and bug -eyes but also defined the luminance requirements on our legend. Mechanical - Permit #M11 -043 1. Please provide structural plans, calculations and framing details for the new rooftop unit loads applied to the existing roof system. Include rooftop unit anchorage details. • We are utilizing the existing curb for our new RTU. The rooftop unit will be installed on this curb as per manufacturer's recommendation and a minimum will be anchored per details 8,9,10 and 11 on sheet M3.0 • A partial roof structural plan has been added to sheet M3.0 for your reference and calculations are being submitted with our resubmittal. 2. The State energy code forms where not filled in adequately. Only submit the applicable forms. We do not need lighting budgets with mechanical permit applications. Complete all required sections of the pages applicable to this system. • The 2009 Washington State energy forms have been completed and attached. Only mechanical forms will be included in this resubmission 3. Please show the location of the proposed HVAC shutdown duct smoke detector on the plans. 3500 West Burbank Boulevard, Burbank, California 91505 818 -972 -5080 Fax: 818 -848 -3895 • • • The HVAC duct smoke detector has been added to the plan on sheet M2.0 Any questions regarding the mechanical revisions can be addressed directly to our consultant Engineer, Kevin Glover at (817) 410 -2858 Additional Revisions In addition to the revisions noted above, we've also made the following changes, deletions, additions, and /or alternations in, on and to the drawings and specifications and all have been noted as revision 1. ARCHITECTURAL Item Sheet Det. Sheet T1.0 T1.0 Sheet A0.2 A0.2 1 Sheet A0.4 A0.4 5 Sheet A1.0 A1.0 1 Sheet A1.1 A1.1 1 Sheet A2.0 A2.0 2 Sheet A2.1 A2.1 Mult. Sheet A2.2 A2.2 Sheet A3.0 A3.0 Sheet A4.0 A4.0 Sheet A5.0 A5.0 Sheet A5.1a A5.1a Sheet AS.2 A5.2 Sheet A6.0 A6.0 Sheet A6.1 A6.1 Sheet A7.0 A7.0 Req'd by Description Bldg. Dept. Bldg. Dept. Number of proposed exits revised to (3), see sheet A0.2 - Entire stockroom layout revised per building department comments. A third exit was added to floor plan. Emergency track lighting and luminance requirements outlined on legend section of sheet. Disney Cashwrap design revised per Disney's direction Bldg. Dept. Demo plan updated per new opening on demising wall that will be required for new 3`" exit. Landlord Demo RCP revised to clarify section of fire sprinkler line that is to remain as is. Bldg. Dept. Entire stockroom layout revised per building department comments. A third exit was added to floor plan. Bldg. Dept. Wall type "H" revised per revised floor plan. Wall type "N" added to set for wall between manager and toilet room. Bldg. Dept. 1 Bldg. Dept. Bldg. Dept. 1 Disney 4 Disney 12,15 Disney Bldg. Dept. Mult. Bldg. Dept. Bldg. Dept. Exit door added to door schedule. Finish plan revised per revised stockroom layout. Reflected ceiling plan revised per revised stockroom layout Finish on storefront revised from a metal panel system to a wood cladding. Section revised per revised change from a metal panel system to a wood dadding finish on storefront. Storefront details revised per change from a metal panel system to a wood cladding finish on storefront. Elevation 10 revised per revised location of sales to stockroom door. Interior elevations revised per revised stockroom layout. Enlarged toilet plan and interior elevations revised per revised stockroom layout. Page 2 Sheet A7.3 A7.3 • Bldg. Dept. Enlarged plans and interior elevations revised per revised stockroom layout. Sheet F1.0 F1.0 Bldg. Dept. Fixture plan revised per revised stockroom layout. Sheet F1.1 F1.1 Bldg. Dept. Fixture layout plan revised per revised stockroom layout. Sheet F2.0 F2.0 Bldg. Dept. Elevation 4 revised per revised location of rear door. MECHANICAL Sheet M2.0 Item Sheet Det. Req'd by Description M2.0 Bldg. Dept. Mechanical plan revised per revised stockroom layout. Also, the location of the duct mounted smoke detector at the RTU was called out. Sheet M3.0 M3.0 Bldg. Dept. Per building department comments, an enlarged roof plan, curb detail and connection detail was called out for RTU units. ELECTRICAL Item Sheet Det. Req'd by Description Sheet E2.0 E2.0 Bldg. Dept. Lighting plan revised per revised stockroom layout. Sheet E3.0 E3.0 Bldg. Dept. Power plan revised per revised stockroom layout. Sheet FA1.0 FA1.0 Bldg. Dept. Fire Alarm plan revised per revised stockroom layout. PLUMBING Item Sheet Det. Req'd by Description Sheet P2.0 P2.0 Bldg. Dept. Plumbing plan revised per revised stockroom layout. Please feel free to give me a call at (818) 972 -5080, ext 123 should you have any questions or concerns. Prepared by Juan Velasquez, LEED AP Project Mana;er 3500 West Burbank Boulevard Burbank, CA 91505 P: (818) 972 -5080 ext. 123 F: (818) 848 -3895 Juanv@linanedrews.coni Page 3 *PERMIT COORD COPY • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL11 -0316 DATE: 05/23/11 PROJECT NAME: DISNEY STORE SITE ADDRESS: 536 SOUTHCENTER MALL Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # X Revision # 1 BEFORE Permit Issued DEPARTMENTS: sir-q B ding Division Public Works Fire Prevention Structural Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 05/24/11 Complete Incomplete Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route T., REVIEWER'S INITIALS: Structural Review Required No further Review Required DATE: APPROVALS OR CORRECTIONS: DUE DATE: 06/21/11 Approved, Approved with Conditions Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 'PERMIT COORDCOPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL11 -0316 DATE: 04/07/11 PROJECT NAME: DISNEY STORE SITE ADDRESS: 536 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # after Permit Issued DEPARTMENTS: C' ,,��11o.�11 � 1 Public Works Fire Prevention Structural n Planning Division ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete n DUE DATE: 04/12/11 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route NA REVIEWER'S INITIALS: Structural Review Required ❑ No further Review Required ❑ DATE: APPROVALS OR CORRECTIONS: DUE DATE: 05/10/11 Approved Approved with Conditions 4J Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite # 100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: -1* ❑ Response to Incomplete Letter # Plan Check/Permit Number: 1 J h Revision # 1 Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Disney Store Project Address: 536 Southcenter Mall Contact Person: S1744- 'Vt LA- CS-VI j Phone Number: at.) 01,-2012r -x';' 110 Summary of Revision: Pk) ll- o53 REC v OP IF Ls MAY 2 3 2011 P111°17'00 .7E14 �, -Nome (5-racr-e62007-A) (Ar epA,A5er 1. Asoi.J 1,1, 9cVu � 1E? tztom- • wtfi r7oN v; .nv N ¶(t) Aria .1v UtO L ' s !ten 3 r !moor C V.-Vsto1-) .p Sheet Number(s): [2. 0 1„,1 LI 44 11/14 tJ f�l. NL., I/0 c-144:77 ord s . "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Entered in Permits Plus on 4 ETA L - 01.1 \applications \forms- applications on line\revision submittal Created: 8 -13 -2004 Revised: DIVISION 16 - ELECTRICAL SECTION 16000 BASIC ELECTRICAL REQUIREMENTS A. GENERAL CONDITIONS 1. DRAWINGS AND GENERAL PROVISIONS OF CONTRACT, INCLUDING GENERAL AND SUPPLEMENTARY CONDITIONS AND ALL OTHER SPECIFICATION SECTIONS, ARE A PART OF THIS CONTRACT. 2. THE GENERAL CONTRACTOR FOR THIS WORK IS REQUIRED TO READ THE ENTIRE SPECIFICATION AND REVIEW DRAWINGS FOR ALL OTHER WADES 3. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR OBTAINING A FULL SET OF BID DOCUMENTS INCLUDING SPECIFICATIONS AND MUST COORDINATE HIS WORK 4. THE GENRAL CONTRACTOR SHALL VISIT THE SITE PRIOR TO SUBMITTING HIS BID TO DETERMINE CONDITIONS AFFECTING THE WORK. BIDS SHALL SERVE AS EVIDENCE OF KNOWLEDGE OF EXISTING CONDITIONS AND ANY MODIFICATIONS WHICH ARE REQUIRED TO MEET THE INTENT OF THE DRAWINGS AND SPECIFICATIONS. FAILURE TO VISIT THE SITE DOES NOT RELIEVE THE CONTRACTOR OF RESPONSIBILITY IN PERFORMANCE OF WORK. 5. WHEN USED, THE TERM "PROVIDED BY GENERAL CONTRACTOR" SHALL BE INTERPRETED AS MEANING "FURNISHED AND INSTALLED BY GENERAL CONTRACTOR" WITH THE EXCEPTION WHERE ITEMS ARE "PROVIDED BY TDS" SHALL BE INTERPRETED AS MEANING "FURNISHED BY TDS" (INSTALLED BY GENERAL CONTRACTOR), EXCEPT WHERE NOTED OTHERWISE. B. GENERAL REQUIREMENTS 1. THE GENERAL CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIALS, EQUIPMENT, SERVICES, TOOLS, TRANSPORTATION, INCIDENTALS AND DETAILS NECESSARY TO PROVIDE A COMPLETE AND FULLY FUNCTIONAL ELECTRICAL SYSTEM AS SHOWN ON THE DRAWINGS, CALLED FOR IN THE SPECIFICATIONS, AND AS REQUIRED BY JOB CONDITIONS. ALL WORK NOT SPECIFICALLY NOTED AS BEING BY THE LANDLORD OR POWER COMPANY SHALL BE PROVIDED BY THE GENERAL CONTRACTOR. CLOSELY COORDINATE THE ENTIRE INSTALLATION WITH LANDLORD AND /OR POWER COMPANY AS REQUIRED. PROVIDE EQUIPMENT THAT IS RATED FOR AVAILABLE FAULT CURRENT LEVELS. FIELD VERIFY THE EXACT TYPE, SIZE, LOCATION, REQUIREMENTS, ETC. OF EXISTING POWER AND TELEPHONE FACILITIES PRIOR TO SUBMISSION OF BID. 2. UNLESS SPECIFICALLY NOTED OTHERWISE, MATERIALS, PRODUCTS, AND EQUIPMENT, INCLUDING ALL COMPONENTS THEREOF, SHALL BE NEW„ UNDERWRITERS LABORATORIES USTED AND LABELED AND SIZED IN CONFORMITY WITH REQUIREMENTS OF THE NATIONAL ELECTRICAL CODE, STATE AND LOCAL CODES, WHICHEVER IS MORE STRINGENT. 3. THE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO SUPPLEMENT EACH OTHER AND ANY MATERIAL OR LABOR CALLED FOR IN ONE SHALL BE PROVIDED EVEN THOUGH NOT SPECIFICALLY MENTIONED IN BOTH. ANY MATERIAL OR LABOR WHICH IS NEITHER SHOWN ON THE DRAWINGS NOR CALLED FOR IN THE SPECIFICATIONS, BUT WHICH IS OBVIOUSLY NECESSARY TO COMPLETE THE WORK OR WHICH IS USUALLY INCLUDED IN WORK OF SIMILAR CHARACTER, SHALL BE PROVIDED AS PART OF CONTRACT. 4, WHERE THE DRAWINGS OR SPECIFICATIONS CALL FOR ITEMS WHICH EXCEED CODES OR THE LANDLORD'S CRITERIA, THE GENERAL CONTRACTOR IS STILL RESPONSIBLE FOR PROVIDING THE SYSTEM AS DESIGNED AND DESCRIBED ON THE DRAWINGS, UNLESS SPECIFICALLY NOTED OTHERWISE. 5, ALL ELECTRICAL WORK SHALL BE INSTALLED SO AS TO BE READILY ACCESSIBLE FOR OPERATION, SERVICING, MAINTENANCE AND REPAIR. 6. THE GENERAL CONTRACTOR SHALL DO ALL CUTTING, CORE DRIWNG, CHASING OR CHANNELING AND PATCHING REQUIRED FOR ANY WORK UNDER THIS DIVISION. CUTTING SHALL HAVE PRIOR APPROVAL BY THE DISNEY STORE PROJECT MANAGER AND THE LANDLORD. PATCHING SHALL MATCH FINISH OF SURROUNDING AREA. 7, THE GENERAL CONTRACTOR SHALL MAKE ALL FINAL ELECTRICAL CONNECTIONS AS REQUIRED FOR A COMPLETE AND OPERATING SYSTEM. C. TEMPORARY UGHT AND POWER 1. THE GENERAL CONTRACTOR SHALL FURNISH AND INSTALL ALL TEMPORARY LIGHT AT A LEVEL OF 30 FOOT CANDLE THROUGHOUT THE SPACE AND POWER WITH RELATED GROUND FAULT INTERRUPTION PROTECTION FOR ALL CONTRACTORS AND IS RESPONSIBLE FOR ITS REMOVAL. 2. THIS GENERAL CONTRACTOR SHALL PAY FOR ALL ELECTRICITY PRIOR TO STORE MERCHANDISING AND SHALL INCLUDE COST IN BID. D. raga 1. ALL WORK SHALL BE PERFORMED IN A NEAT AND PROFESSIONAL MANNER USING GOOD ENGINEERING PRACTICES. ALL WORK SHALL CONFORM TO THE LATEST ADOPTED EDITION OF THE NATIONAL ELECTRICAL CODE; LANDLORD'S CRITERIA; THE STATE'S, COUNTYS, CITYS AND LOCAL CODES AND ORDINANCES; SAFETY AND HEALTH CODES; NFPA CODES; ENERGY CODES; AND ALL OTHER APPUCABLE CODES AND REQUIREMENTS. THE GENERAL CONTRACTOR SHALL INQUIRE 0 INTO AND COMPLY WITH ALL APPLICABLE CODES, ORDINANCES, AND REGULATIONS. THE GENERAL CONTRACTOR SHALL INCLUDE ANY CHANGES REQUIRED BY CODES IN THE BID. AFTER CONTRACT IS ISSUED, NO ADDITIONAL COST DUE TO CODE ISSUES SHALL BE REIMBURSED BY DISNEY TO THE GENERAL CONTRACTOR. E. LICENSES. PERMITS. INSPECTIONS & FEES 1. THE GENERAL CONTRACTOR SHALL OBTAIN AND PAY FOR ALL LICENSES, PERMITS, INSPECTIONS, AND FEES REQUIRED OR RELATED TO HIS WORK. 2. FURNISH TO THE TDS PROJECT MANAGER ALL CERTIFICATES OF INSPECTION AND FINAL INSPECTION APPROVAL AT COMPLETION OF PROJECT. F. SHOP DRAWINGS 1. SUBMIT TWO COPIES OF MATERIAL LISTS AND SHOP DRAWINGS FOR ALL EQUIPMENT TO THE GENERAL CONTRACTOR FOR APPROVAL PRIOR TO ORDERING EQUIPMENT. SUBMISSIONS SHALL BE MADE EARLY ENOUGH IN PROJECT TO ALLOW EIGHT WORKING DAYS FOR THE GENERAL CONTRACTOR TO REVIEW SUBMITTAL WITHOUT CAUSING DELAYS OR CONFLICTS TO THE JOB'S PROGRESS. SUBMITTALS SHALL BE IN ACCORDANCE WITH GENERAL CONDITIONS AND THE MANUFACTURER'S LISTED ON THE DRAWINGS. SHOP DRAWINGS SHALL INCLUDE ALL DATA THAT PERTAINS TO THE REQUIREMENTS SET FORTH ON THE DRAWINGS AND IN THE SPECIFICATIONS. SUBMITTALS SHALL BEAR THE STAMP OF THE GENERAL CONTRACTOR AND SUB - CONTRACTOR SHOWING THAT HE HAS REVIEWED AND CONFIRMED THAT THEY ARE IN CONFORMANCE WITH THE CONTRACT DRAWINGS AND SPECIFICATIONS. ANY EXCEPTIONS TO SPECIFICATIONS OR DRAWINGS SHALL BE INDICATED TO TENANT PROJECT MANAGER. LACK OF SUCH CONTRACTOR'S REVIEW AND APPROVAL WILL BE CAUSE FOR REJECTION WITHOUT REVIEW BY TENANT PROJECT MANAGER. G. TRADE NAMES AND MANUFACTURERS 1. WHERE TRADE NAMES AND MANUFACTURERS ARE USED ON THE DRAWINGS OR IN THE SPECIFICATIONS, THE EXACT EQUIPMENT SHALL BE USED AS A MINIMUM STANDARD FOR THE BASE BID. MANUFACTURERS CONSIDERED AS AN EQUAL OR BETTER IN ALL ASPECTS TO THAT SPECIFIED WILL BE SUBJECT TO APPROVAL IN WRITING BY TENANT PROJECT MANAGER PRIOR TO ACCEPTANCE. THE USE OF ANY UNAUTHORIZED EQUIPMENT SHALL BE SUBJECT TO REMOVAL AND REPLACEMENT AT THE GENERAL CONTRACTOR'S EXPENSE. H. GUARANTEE 1. THE GENERAL CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORK UNDER HIS CONTRACT AND SHALL MAKE GOOD, REPAIR OR REPLACE AT HIS OWN EXPENSE, ANY DEFECTIVE WORK, MATERIAL, OR EQUIPMENT WHICH MAY BE DISCOVERED WITHIN A PERIOD OF 12 MONTHS FROM THE DATE OF ACCEPTANCE (IN WRITING) OF THE INSTALLATION BY THE TENANT PROJECT MANAGER. PROVIDED EXTENDED WARRANTIES AS SPECIFIED WITH INDIVIDUAL EQUIPMENT. I. RECORD DRAWINGS 1. THE GENERAL CONTRACTOR SHALL MAINTAIN ONE COPY OF DRAWINGS AND SPECIFICATIONS ON THE JOB SITE TO RECORD DEVIATIONS FROM CONTRACT DRAWINGS, SUCH AS: A. LOCATION OF JUNCTION BOXES AND RECEPTACLES. B. REVISIONS, ADDENDUMS, AND CHANGE ORDERS. C. SIGNIFICANT DEVIATIONS MADE NECESSARY BY FIELD CONDITIONS, APPROVAL EQUIPMENT SUBSTITUTIONS, AND CONTRACTOR'S COORDINATION WITH OTHER TRADES. D. ROUTING OF ANY UNDERGROUND OR UNDER SLAB CONDUITS. 2. AT COMPLETION OF PROJECT AND BEFORE FINAL APPROVAL, THE GENERAL CONTRACTOR SHALL MAKE ANY FINAL CORRECTIONS TO DRAWINGS AND CERTIFY THE ACCURACY OF EACH PRINT BY SIGNATURE THEREON AND TURN OVER TO THE DISNEY. J. DISCREPANCIES IN DOCUMENTS 1. DRAWINGS (PLANS, ,SPECIFICATIONS, AND DETAILS) ARE DIAGRAMMATIC AND INDICATE THE GENERAL LOCATION AND INTENT OF THE ELECTRICAL SYSTEMS. WHERE DRAWINGS, EXISTING SITE CONDITIONS, SPECIFICATIONS OR OTHER TRADES CONFLICT OR ARE UNCLEAR, ADVISE THE GENERAL CONTRACTOR IN WRITING PRIOR TO SUBMITTAL OF BID. THE GENERAL CONTRACTOR IS RESPONSIBLE TO ADVISE THE TENANT PROJECT MANAGER IN WRITING OF ANY VARIATIONS TO CONTRACT DOCUMENTS PRIOR TO SUBMISSION OF THE BID. OTHERWISE, THE TDS PROJECT MANAGER'S INTERPRETATION OF CONTRACT DOCUMENTS OR CONDITIONS SHALL BE FINAL WITH NO ADDITIONAL COMPENSATION PERMITTED. 2, THE LOCATION OF OUTLETS AND EQUIPMENT SHOWN ON THE DRAWINGS ARE APPROXIMATE AND SCHEMATIC IN NATURE. TDS SHALL HAVE THE RIGHT TO RELOCATE ANY OUTLETS OR FIXTURES PRIOR TO ROUGH -IN WITHOUT ADDITIONAL COST, UP TO 10 FEET. K. SLEEVES 1. THE GENERAL CONTRACTOR SHALL PROVIDE SLEEVES TO PROTECT EQUIPMENT OR FACILITIES IN THE INSTALLATION. EACH SLEEVE SHALL EXTEND THROUGH ITS RESPECTIVE FLOOR, WALL OR PARTITION AND SHALL BE CUT FLUSH WITH EACH SURFACE EXCEPT SLEEVES THAT PENETRATE THE FLOOR, WHICH SHALL EXTEND 2" ABOVE THE FLOOR. 2. ALL SLEEVES AND OPENINGS THROUGH FIRE RATED WALLS AND /OR FLOORS SHALL BE FIRE SEALED WITH CALCIUM SIUCATE, SILICONE "RTV" FOAM, "3M" FIRE RATED SEALANTS OR EQUAL SO AS TO RETAIN THE FIRE RATING OF THE FLOOR OR WALL. CONFORM TO U.L. ASSEMBLY RATING OF FLOOR OR WALL 3. SLEEVES IN BEARING AND MASONRY WALLS, FLOORS AND PARTITIONS SHALL BE STANDARD WEIGHT BLOCK STEEL PIPE FINISHED WITH SMOOTH EDGES. FOR OTHER THAN MASONRY PARTITIONS, THROUGH SUSPENDED CEILINGS, OR FOR CONCEALED VERTICAL CONDUIT, SLEEVES SHALL BE NO. 22 U.S.G. GALVANIZED STEEL MINIMUM. L HANGERS M N. 1. HANGERS SHALL INCLUDE ALL MISCELLANEOUS STEEL SUCH AS ANGLE IRON, WIRE, UNISTRUT, C- CLAMPS WITH RETAINING CUPS, CHANNELS, HANGER RODS, ETC., NECESSARY FOR THE INSTALLATION OF WORK. 2, HANGERS SHALL BE FASTENED TO BUILDING STEEL CONCRETE, OR MASONRY, BUT NOT TO OTHER CONDUIT, DUCTWORK OR PIPING. HANGERS UPPER ATTACHMENT MUST BE SUPPORTED FROM THE TOP OF THE BAR JOIST. HANGING FROM METAL DECK IS NOT PERMITTED. WHERE INTERFERENCE OCCUR, IN ORDER TO SUPPORT CONDUIT, THE CONTRACTOR MUST INSTALL TRAPEZE TYPE HANGERS OR SUPPORTS WHICH SHALL BE LOCATED WHERE THEY DO NOT INTERFERE WITH ACCESS TO FIRE DAMPERS, VALVES, JUNCTION BOXES, ACCESS DOORS, OTHER EQUIPMENT SERVICE REQUIREMENTS AND /OR OTHER TRADES. HANGER TYPES AND INSTALLATION METHODS ARE SUBJECT TO LANDLORD CRITERIA AND AS DIRECTED BY THE TDS PROJECT MANAGER. OPERATIONS MANUALS 1. ONE COPY OF EACH OPERATION AND MAINTENANCE MANUAL FOR ALL EQUIPMENT FURNISHED ON JOB SHALL BE COLLECTED AND INSERTED IN A 3" THREE RING BINDER AND SENT TO THE OFFICE OF THE DISNEY STORE'S PROJECT MANAGER. FINAL ELECTRICAL INSPECTIONS 1. ASIDE FROM NORMAL INTERIM INSPECTIONS OF WORK IN PLACE, THE DISNEY STORE SHALL HAVE THE RIGHT TO HAVE AN INDEPENDENT GENERAL CONTRACTOR INSPECT THE FINISHED ELECTRICAL INSTALLATION UPON COMPLETION FOR COMPUANCE WITH THE PLANS, SPECIFICATIONS AND CODES. THE ORIGINAL GENERAL CONTRACTOR WILL BE RESPONSIBLE TO BRING ALL ITEMS REPORTED UP TO PLAN AND SPECIFICATION REQUIREMENTS AT NO COST TO THE DISNEY STORE. SECTION 16050 BASIC ELECTRICAL MATERIALS AND METHODS A. SCOPE OF WORK 1. THE GENERAL CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, EQUIPMENT, SERVICES, TOOLS, TRANSPORTATION, AND FACILITIES NECESSARY FOR, REASONABLY IMPUED AND INCIDENTAL TO, THE FURNISHING, INSTALLATION, COMPLETION AND TESTING OF ALL THE WORK FOR THE ELECTRICAL SYSTEMS AS SHOWN ON THE DRAWINGS, CALLED FOR IN THE SPECIFICATIONS, AND AS REQUIRED BY JOB CONDITIONS, TO INCLUDE, BUT NOT BE UMITED TO THE FOLLOWING: a. A COMPLETE ELECTRICAL DISTRIBUTION SYSTEM INCLUDING SERVICE AND DISTRIBUTION EQUIPMENT AS SHOWN ON THE DRAWINGS. ALSO, FEEDERS, BRANCH CIRCUIT PANELS, BRANCH CIRCUITS, JUNCTION BOXES, OUTLET BOXES, WIRING DEVICES, COVERPLATES, CONDUITS, WIRES, ETC. b. METERING EQUIPMENT AS SHOWN ON THE DRAWINGS AND AS REQUIRED BY THE UTILITY COMPANY AND /OR LANDLORD. c. THE WIRING OF MECHANICAL EQUIPMENT AS OUIUNED ON THE DRAWINGS AND IN THE SPECIFICATIONS. WORK SHALL INCLUDE ALL STARTERS, DISCONNECTS, AND POWER WIRING OF MECHANICAL EQUIPMENT EXCEPT AS SPECIFICALLY NOTED OTHERWISE. ALL LOW VOLTAGE (24 VOLT) TEMPERATURE CONTROL WIRING SHALL BE THE RESPONSIBILITY OF THE MECHANICAL CONTRACTOR UNLESS OTHERWISE SPECIFICALLY N NOTED ON DRAWINGS. CONDUIT & PULL STRINGS FOR CONTROL WIRING IS TO BE INCLUDED BY. G.C. . INSTALLATION OF UGHT FIXTURES AND LAMPS AS SHOWN ON THE DRAWINGS INCLUDING ALL DEVICES, EQUIPMENT, ETC. REQUIRED FOR MOUNTING. • INSTALLATION OF THE ENTERTAINMENT LIGHTING SYSTEM COMPONENTS INCLUDING ALL UNE VOLTAGE AND LOW VOLTAGE DATA CABLES HOOK -UPS AND DIMMING SYSTEM AS SHOWN ON THE DRAWINGS. A COMPLETE CONDUIT SYSTEM FOR TELEPHONE/DATA INCLUDING TERMINAL BOARD, BRANCH CONDUITS, OUTLET BOXES, PULL WIRES, GROUND CONDUCTORS, COVERPLATES, ETC. A COMPLETE EMERGENCY AND EXIT UGHTING SYSTEM AS SHOWN ON THE DRAWINGS. . TEMPORARY SERVICE AS INDICATED IN THE SPECIFICATIONS, INCLUDING ITS REMOVAL FINAL CONNECTIONS TO ALL SIGNS, CORNICE LIGHTING, CASE UGHTING, ETC. AS SHOWN ON DRAWINGS. INSTALLATION OF CONDUIT WITH PULL WIRES FOR SOUND SYSTEM AS SHOWN ON DRAWINGS. • SMOKE /FIRE ALARM WRING, DEVICES AND CONDUIT, AS SHOWN OR DESCRIBED ON DRAWINGS TO MEET LANDLORD, STATE, LOCAL, INSURANCE AND FIRE DEPARTMENT REQUIREMENTS. INSTALLATION OF DATA LINE WRING AND CONDUIT. CABLE AND FINAL CONNECTIONS BY TDS. 2. WORK NOT INCLUDED THE FOLLOWING ITEMS OF ELECTRICAL CONSTRUCTION ARE NOT INCLUDED IN THIS CONTRACT: a. 24 VOLT TEMPERATURE CONTROL WIRING b. TELEPHONE INSTRUMENTS AND WIRING c. STEREO AND SPEAKER WIRING. d. FINAL DATA UNE CONNECTIONS. e. SEE RESPONSIBILITY TABLE ON E1.0 FOR MORE INFORMATION, 3. BEFORE STARTING WORK, THE GENERAL CONTRACTOR SHALL EXAMINE THE ARCHITECTURAL, STRUCTURAL, FIRE PROTECTION, MECHANICAL AND PLUMBING PLANS, SHOP DRAWINGS AND SPECIFICATIONS TO SEQUENCE, COORDINATE, AND INTEGRATE THE VARIOUS ELEMENTS OF THE ELECTRICAL SYSTEM, MATERIALS, AND EQUIPMENT WITH OTHER CONTRACTORS TO AVOID INTERFERENCE AND CONFRONTATIONS. B. CONDUIT 1.. THE GENERAL CONTRACTOR SHALL PROVIDE ALL CONDUITS SERVING ALL EQUIPMENT, INCLUDING BUT NOT LIMITED TO, UGHTING, RECEPTACLES, HEATING, AIR CONDITIONING, PLUMBING EQUIPMENT, TELEPHONE, AND ELECTRICAL EQUIPMENT. 2. ALL PANEL AND SERVICE FEEDERS SHALL BE IN GALVANIZED IMC 2" AND LARGER AND EMT FOR UNDER 2" AS REQUIRED BY LOCAL CODES AND THE LANDLORD. ALL CONDUIT IS TO BE UL LABELED. EMT SHALL BE ACCEPTABLE FOR BRANCH CIRCUITS RUN ABOVE SUSPENDED CEILINGS OR CONCEALED IN INTERIOR PARTITIONS. EMT CONNECTORS SHALL BE STEEL SET SCREW TYPE. CONDUIT UNDER SLAB ON GRADE SHALL BE RIGID STEEL OR A.B.S. 3. MINIMUM SIZES OF CONDUIT SHALL BE 1/2" FOR INDIVIDUAL LIGHTING FIXTURE CONNECTIONS OR TO INDIVIDUAL LIGHT SWITCHES AND 3/4" FOR ALL OTHER LOCATIONS. HVAC CONTROL WIRING IS REQUIRED TO BE RUN IN CONDUIT, IT SHALL BE MINIMUM OF 3/4' SIZE, UNLESS NOTED OTHERWISE ON DRAWINGS. ALL IN/UNDER FLOOR SLAB CONDUIT SHALL BE OF MINIMUM 3/4" SIZE. 4. SUPPORT ALL CONDUIT, INCLUDING SEISMIC AND SWAY BRACING, IN ACCORDANCE WITH THE NEC AND LOCAL CODES. 5. GENERALLY, ALL CONDUIT SHALL BE CONCEALED EXCEPT FOR UNFINISHED AREAS, SUCH AS EQUIPMENT ROOMS. EXPOSED CONDUIT SHALL BE ALLOWED ONLY AS NOTED ON PLAN AND AS APPROVED BY THE DISNEY STORE PROGRAM MANAGER. PAINTING OF CONDUITS WILL BE BY GENERAL CONTRACTOR. 6. FLEXIBLE METAL CONDUIT OR "MC" TYPE CABLE a. BOTH THE FLEXIBLE METAL CONDUIT AND 'MC" TYPE CABLE AND THEIR ASSOCIATED FITTINGS ARE TO BE LISTED FOR GROUNDING. A GREEN GROUNDING CONDUCTOR SHALL BE PROVIDED FOR IN EITHER TYPE. ALL CONNECTORS ARE TO BE OF A NEMA APPROVED TYPE. b. FLEXIBLE CONDUIT OR "MC" TYPE CABLE SHALL BE ACCEPTABLE FOR THE FOLLOWING APPLICATIONS AND SHALL NOT EXCEED 6 FEET IN LENGTH: 1. FINAL CONNECTIONS TO MOTORS. 2. FINAL CONNECTIONS INTO AND OUT OF THE TRANSFORMER. 3. FINAL CONNECTIONS TO OUTLETS ON VIBRATING EQUIPMENT. 4. FINAL INTER - CONNECTIONS BETWEEN UGHT FIXTURES. 5. FINAL CONNECTIONS WHERE RIGID CONDUIT IS NOT PRACTICAL 6. IN HIDDEN CONDITIONS WHERE PERMITTED BY CODE. c. THE USE OF ROMEX, IS NOT PERMITTED. d. CONNECTION TO OUTDOOR EQUIPMENT MUST BE WEATHERPROOF, I.E. UQUIDTIGHT OR SEALTIGHT. 7. PROVIDE PULL- STRING IN ALL EMPTY CONDUITS. 8. HOME RUNS AND MAIN CONDUIT RUNS ARE TO BE HELD TIGHT TO STRUCTURE ABOVE OR AS REQUIRED TO ALLOW PROPER CLEARANCE OF CEILING AND OTHER TRADES WORK. 9. ALL CONDUIT SHALL BE RUN PARALLEL OR PERPENDICULAR TO COLUMN LINES. 10. ALL CONDUITS MUST BE SIZED PER NEC AND LOCAL CODES AND AS SPECIFIED. C OUTLET BOXES 1, ALL OUTLET BOXES SHALL BE GALVANIZED PRESSED STEEL OF THE STANDARD KNOCKOUT TYPE. NO ROUND OUTLET BOXES SHALL BE PERMITTED, EXCEPT AS SPECIFICALLY NOTED ON DRAWINGS. BOXES SHALL BE OF THE NEC CODE SIZE FOR THE NUMBER OF WIRES PASSING THROUGH OR TERMINATING THEREIN BUT IN NO CASE SHALL BE SMALLER THAN 2 1/8" SQUARE. 2. ALL KNOCKOUT BOXES, UPON WHICH LIGHTING FIXTURES ARE TO BE INSTALLED, SHALL BE EQUIPPED WITH 3/8' FIXTURE STUDS. 3. EXTERIOR BOXES SHALL BE CAST RUST - RESISTING METAL WITH GASKETED COVERS. 4. INSTALL BOXES RIGIDLY FROM BUILDING STRUCTURE AND SUPPORT INDEPENDENTLY OF THE CONDUIT SYSTEM. ALSO PROVIDE SUITABLE BOX EXTENSIONS TO EXTEND BOXES TO FINISHED FACES OF FLOORS, CEILINGS, WALLS ETC. ALL RECEPTACLE OUTLET BOXES TO HAVE SUITABLE BLOCKING BEHIND THEM OR PRE - MANUFACTURED 'CADDY' TYPE BRACING CUPS ADDED TO MINIMIZE THE DEFLECTION THAT OCCURS WHEN PLUGGING /UNPLUGGING INTO THESE DEVICES. 5. WHERE A 277 VOLT LIGHT SWITCH IS GANGED WITH A 120 VOLT RECEPTACLE OR LIGHT SWITCH, PROVIDE A SUITABLE DIVIDER OR SEPARATE JUNCTION BOXES IN ACCORDANCE WITH NEC AND LOCAL CODES. 6, UNLESS OTHERWISE NOTED ON DRAWINGS OR OTHERWISE REQUIRED BY THE NATIONAL ELECTRIC CODE, HANDICAP CODES OR LOCAL CODES, OUTLET HEIGHTS SHALL BE AS FOLLOWS: a. SWITCH HEIGHT 48" A.F.F. TO CENTERLINE OF SWITCH. b. CONVENIENCE OUTLETS: SALES: SHALL BE INSTALLED ON B.O. FIXTURE BASE NON- SALES: 18" A.F.F. TO CENTERLINE OF RECEPTACLE., U.O.N c. TELEPHONE OUTLETS HEIGHT TO CENTERLINE OF OUTLET PER PLAN. D. JUNCTION AND PULL BOXES 1. THE PLANS INDICATE ONLY SCHEMATIC ROUTINGS FOR CONDUIT RUNS. THIS CONTRACTOR SHALL PROVIDE ADDITIONAL BOXES WHERE REQUIRED BY FIELD CONDITIONS OR BY CODES. 2. BOXES AND COVERS SHALL BE OF CODE GAUGE GALVANIZED STEEL 3. INSTALL BOXES RIGIDLY SUPPORTED FROM THE BUILDING STRUCTURE AND SUPPORTED INDEPENDENT OF THE CONDUIT SYSTEM. 4. ARRANGE CIRCUITS TO AVOID THE USE OF JUNCTION BOXES ABOVE DRYWALL CEILING AND OTHER INACCESSIBLE LOCATIONS. E. WIRING 1. CONDUCTORS FOR FEEDERS AND BRANCH CIRCUITS SHALL BE COPPER AND THE AWG SIZE AND TYPE AS SHOWN ON DRAWINGS. MINIMUM WIRE SIZE SHALL BE #12. THECONDUCTORS SHALL HAVE 600 VOLT INSULATION, TYPE THW, THWN OR THHN. 2. MINIMUM WIRE SIZE - 20 AMP. BRANCH CIRCUIT SHALL BE AWG USTED SIZE PER DISTANCE SHOWN BELOW. DISTANCE SHALL BE MEASURED FROM THE PANELBOARD CIRCUIT BREAKER TO THE FURTHEST OUTLET (ALSO SEE PLANS FOR FURTHER INFO.): a. #12 LESS THAN 100 FEET b. #10 OVER 100 FEET 3. CONDUCTORS SHALL BE STRANDED FOR SIZES #10 AWG AND LARGER (UON). 4. ALUMINUM CONDUCTORS ARE NOT PERMITTED. 5. ALL WIRING SHALL BE IN CONDUIT. LOW VOLTAGE PLENUM RATED WIRE (CONTROL, SPEAKER ETC.) SHALL BE ALLOWED IN HIDDEN CONDITIONS, WHERE ALLOWED BY CODE AND APPROVED IN WRITTING BY THE DISNEY STORE PROJECT MANAGER. 6. THE USE OF SHARED NEUTRALS IS ALLOWED FOR LIGHTING AND NON -SURGE SUPPRESSOR AND ISOLATED GROUND RECEPTACLE CIRCUITS AND SHALL BE INSTALLED IN ACCORDANCEWITH THE NATIONAL ELECTRIC CODES AND LOCAL CODES. ALL OTHER EQUIPMENT SHALL HAVE A DEDICATED FULL SIZE NEUTRAL 7. THE USE OF ROMEX, IS NOT PERMITTED. 8. %IRE CONNECTORS SHALL BE EQUAL TO 'SCOTCH LOCK' FOR #8 AWG WIRE AND SMALLER AND EQUAL TO T & B "LOCKTIGHT" FOR #8 AWG AND LARGER. EQUALS BY BUCHANAN ARE ACCEPTABLE. 9. ALL WIRING TO BE COLOR -CODED AS FOLLOWS: 120/208 VOLT SYSTEM. NEUTRAL - WHITE PHASE A OR L1 -BLACK PHASE B OR L2 -RED PHASE C OR L3 -BLUE GROUND -GREEN ISOLATED GROUND: GREEN -YELLOW STRIPED 277/480 VOLT SYSTEM NEUTRAL - GRAY PHASE A OR L1 - BROWN PHASE B OR L2- ORANGE PHASE C OR L3- YELLOW GROUND -GREEN WITH TRACER F. GROUNDING 1. PROVIDE COMPLETE WIRED GROUNDING CONDUCTOR SYSTEM, #12 AWG MINIMUM, SIZED AND INSTALLED IN ACCORDANCE WITH THE LATEST ADOPTED EDITION OF THE NATIONAL ELECTRICAL CODE, STATE AND LOCAL CODES, THE LANDLORD'S CRITERIA AND AS NOTED IN THE SPECIFICATIONS AND AS INDICATED ON THE DRAWINGS. 2. GROUNDING CONNECTIONS MADE TO THE WATER PIPING SYSTEM SHALL BE COORDINATED WITH THE PLUMBING CONTRACTOR AND BONDING JUMPERS SHALL BE INSTALLED PER CODES AND AS INDICATED ON DRAWINGS. 3. ALL DEVICES SHALL BE BONDED TO THE CONDUIT SYSTEM. USE A BONDING JUMPER BETWEEN THE OUTLET BOX AND THE DEVICE GROUNDING TERMINAL METAL -TO- METAL CONTACT BETWEEN THE DEVICE YOKE AND THE OUTLET BOX IS NOT ACCEPTABLE AS A BOND FOR EITHER SURFACE MOUNTED BOXES OR FLUSH TYPE BOXES. ALL JUNCTION BOXES, OUTLET BOXES, AND PULL BOXES SHALL BE BONDED TO THE CONDUIT SYSTEM. ALL CONDUIT, INCLUDING FLEXIBLE CONDUIT, SHALL BE GROUNDED WITH A GREEN GROUNDING CONDUCTOR. 4. RUN A SEPARATE DEDICATED #10 AWG MINIMUM GROUNDING CONDUCTOR IN EACH CONDUIT FEEDING THE CASH REGISTER, THE SENSORMATIC, AND OTHER COMPUTERIZED EQUIPMENT AS SHOWN ON DRAWINGS. FOR PANEL FEEDERS, BOND THE GROUNDING CONDUCTOR TO THE CONDUIT, WHERE ENTERING AND LEAVING THE CONDUIT. THE GROUNDING CONDUCTOR SHALL BE SIZED PER 5. ALLEENCCLLOSURESLAND COLORED, COPPER CARRYING METAL PARTS ARE TO BE GROUNDED. CONDUIT SYSTEM IS TO BE ELECTRICALLY CONTINUOUS. ALL LOCK NUTS MUST CUT THROUGH ENAMELED OR PAINTED SURFACES ON ENCLOSURES. WHERE ENCLOSURES AND NON- CURRENT CARRYING METAL PARTS ARE ISOLATED FROM THE CONDUIT SYSTEM, USE BONDING JUMPERS WITH APPROVED CLAMPS. ALL GROUND CLAMPS SHALL BE "PENN - UNION" OR EQUAL SIMILAR TO 'GPL" TYPE. 6. NO OTHER CIRCUITS ARE TO BE RUN IN SAME CONDUIT FEEDING ISOLATED GROUND RECEPTACLES. G. EQUIPMENT WIRING 1. ALL EQUIPMENT FURNISHED AND INSTALLED UNDER CONTRACTS OTHER THAN THE ELECTRICAL CONTRACT SHALL BE FURNISHED WITH FULL COMPLEMENT OF CONTROL EQUIPMENT AND CONTROL WIRING DIAGRAMS NECESSARY FOR SATISFACTORY OPERATION. 2. THE GENERAL CONTRACTOR SHALL COMPLETE ALL ELECTRICAL CONNECTIONS THROUGH THE DISCONNECT, STARTER AND MOTOR TERMINALS. 3. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR PROPER ROTATION OF ALL THREE PHASE EQUIPMENT. 4. EQUIPMENT FURNISHED BY OTHERS SHALL BE ROUGHED IN WITH CONDUIT AND BOXES BY MANUFACTURER. INTERNAL WIRING SHALL BE COMPLETED ACCORDING TO THE MANUFACTURER'S SHOP DRAWINGS OF THE EQUIPMENT BY GENERAL CONTRACTOR. THE GENERAL CONTRACTOR IS TO WIRE TO ALL UNE VOLTAGE CONTROLS AND CONTROLLERS. H HEATING. VENTILATING & AIR CONDITIONING. PLUMBING. AND FIRE PROTECTION WIRING 1. GENERAL CONTRACTOR SHALL REFER TO MECHANICAL DRAWINGS FOR ADDITIONAL ELECTRICAL WORK TO BE INCLUDED IN HIS BID. 2. GENERAL CONTRACTOR SHALL DO ALL POWER WIRING, UNE VOLTAGE WIRING, AND LOW VOLTAGE CONTROL WIRING INDICATED UNDER THE HEATING, VENTILATION AND AIR CONDITIONING, PLUMBING AND FIRE PROTECTION SPECIFICATIONS AND DRAWINGS. MECHANICAL CONTRACTOR SHALL DO ALL INTERCONNECTING WIRING BETWEEN RELAYS AND SWITCHES AS REQUIRED. 3. GENERAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING CONDUIT FOR HVAC CONTROL WIRING. I WIRING DEVICES 1. THE GENERAL CONTRACTOR SHALL FURNISH AND INSTALL SWITCHES AND RECEPTACLES AS SHOWN ON THE DRAWINGS AND NECESSARY FOR A COMPLETE INSTALLATION. COLOR OF DEVICES AND PLATES SHALL BE IVORY UNLESS NOTED OTHERWISE. THE DEVICES SHALL BE OF THE TYPES AND RATINGS LISTED. WEATHERPROOF GFI RECEPTACLES SHALL BE INSTALLED WHERE SHOWN ON DRAWINGS OR AS REQUIRED BY CODE. SINGLE POLE SWITCHES: 20 A - 120/277 V LEVITON -1201 IVORY THREE WAY SWITCHES: 20 A - 120/277 V LEVITON -1203 IVORY DUPLEX RECEPTACLES: 15 A - 125 V LEVITON- 5262 -I IVORY ISOLATED GROUND RECEPTACLES: 15 A - 125 V LEVITON- 5262 -10 (ORANGE TRIANGLE ON FACE) FLOOR OUTLET BOX: HUBBELL #8 -2427 FLOOR OUTLET BRASS COVER: HUBBELL #5 -3825 FLOOR OUTLET BRASS CARPET FLANGE: HUBBELL #S8 -3083 GFCI RECEPTACLES: 15 A -125V LEVITON - 6599 -1 (IVORY) 2. ALL DEVICE COVERPLATES SHALL BE IVORY OR BLACK, TAMPER - RESISTANT PLATE - HUBBELL - RR15SITR (IVORY) OR RR15SBKTR (BLACK) SERIES "RR" OR EQUAL J. SAFETY AND DISCONNECT SWITCHES 1. SAFETY AND DISCONNECT SWITCHES SHALL BE HEAVY DUTY TYPE, QUICK -MAKE, QUICK -BREAK FUSED OR NON- FUSIBLE WITH RATINGS AND SIZES AS NOTED ON PLANS AND REQUIRED BY CODES. 2. SWITCHES SHALL BE WEATHERPROOF IN OUTDOOR LOCATIONS OR AS REQUIRED BY LOCAL CODES. 3. DISCONNECT SWITCHES THAT ARE INSTALLED AT HEATING, VENTILATING AND AIR CONDITIONING (HVAC) EQUIPMENT SHALL BE FUSED IF NOT PROTECTED WITH A "HACR" BREAKER IN ACCORDANCE WITH THE EQUIPMENTS NAMEPLATE AND MANUFACTURER'S REQUIREMENTS PER THE NATIONAL ELECTRICAL, STATE AND LOCAL CODES. CONTRACTOR IS TO COORDINATE AU. WORK. 4. AT SERVICE ENTRANCE, DISCONNECT SHALL BEAR THE MANUFACTURER'S LABEL INDICATING THE EQUIPMENT IS UL RATED FOR "SERVICE ENTRANCE" APPUCA11ON. (AS INDICATED ON THE DRAWINGS). 5. MANUFACTURER SHALL BE EATON, G.E., SQ -D, AND SIEMENS. K. MOTOR STARTERS 1. MANUAL MOTOR STARTERS WIN OVERLOAD PROTECTION MAY BE USED FOR FRACTIONAL HORSEPOWER MOTORS THAT DO NOT REQUIRE AUXIUARY CONTROL THREE PHASE STARTERS SHALL BE PROVIDED WITH OVERLOAD DEVICE IN EACH PHASE MATCHED TO MOTOR NAMEPLATE RATING. MAGNETIC MOTOR STARTERS SHALL BE ELECTRICALLY HELD(SIZE AS SHOWN) AND BE USED FOR ALL SINGLE PHASE AND THREE PHASE MOTORS RATED ABOVE 1/2 HP OR THAT REQUIRE AUXIUARY CONTROL PROVIDE CONTROL DEVICES (AUXILIARY CONTACTS, TRANSFORMERS, ETC.) IN STARTERS AS REQUIRED FOR INTERLOCKS PROVIDED BY CONTRACTOR. COMBINATION STARTERS SHALL CONTAIN FUSIBLE SWITCHES. MOTORS AND STARTERS SHALL BE PROVIDED BY THE CONTRACTOR, FINAL CONNECTIONS TO BE PROVIDED BY THE GENERAL CONTRACTOR. 2. MANUFACTURER SHALL BE EATON, G.E., SQ -D, AND SIEMENS. L PANELBOARDS 1. ALL PANELBOARDS SHALL BE FACTORY ASSEMBLED OF THE BOLTED CIRCUIT BREAKERS TYPE WITH SOLID COPPER BUSSING, FULL SIZED NEUTRAL, 100 % GROUND BUSSING, AND OVERALL HINGED /LOCKABLE DOOR. ALL CIRCUIT BREAKERS SHALL BE OF THE QUICK -MAKE AND QUICK -BREAK DESIGN, THERMAL - MAGNETIC TYPE, TRIP FREE AND TRIP- INDICATING. ALL PANELS SHALL BE DEAD FRONT AND FLUSH OR SURFACE MOUNTED AS SHOWN AND SHALL BE FURNISHED WITH A TYPEWRITTEN DIRECTORY CARD OF THE CIRCUITS AND AN ENGRAVED NAMEPLATE. 2. CIRCUIT BREAKER PANELBOARDS SHALL HAVE FULL LENGTH NON- TAPERED BUS BARS ARRANGED AND DRILLED FOR SEQUENCE PHASING. 3. ALL PANELS SHALL HAVE DOORS FLUSH WITH THE TRIM, EQUIPPED WITH LOCKS, AND KEYED ALIKE. ALL MULTI-POLE BREAKERS SHALL BE COMMON TRIP. 4. PANELS SHALL BE AS INDICATED ON THE DRAWINGS. ALL BRANCH CIRCUIT BREAKERS (C /B) SHALL BE RATED 20 AMPERES SINGLE POLE MINIMUM, EXCEPT AS NOTED OR REQUIRED BY LOCAL CODES. 5. PROVIDE SCREW TYPE LOCK ON DEVICES WIN THE CIRCUIT BREAKERS AS INDICATED ON PANEL SCHEDULE. PROVIDE (6) ADDITIONAL CUPS TO BE INSTALLED AS DIRECTED BY 'THE TDS PROJECT MANAGER. 6. PROVIDE ONE SPARE 1" CONDUIT FOR EACH SIX SPACES OR SPARE CIRCUIT BREAKERS IN EACH RECESSED MOUNTED PANEL MINIMUM 1- SPARE CONDUIT PER PANEL RUN CONDUIT TO A LOCATION JUST ABOVE CEILING. 7. ALL CIRCUIT BREAKERS FEEDING UGHTING LOADS SHALL BE LISTED AND SHALL BE MARKED "SWD ". (SWITCHING DUTY) 8. CIRCUIT BREAKERS SERVING HEATING, VENTILATION, AND /OR AIR CONDITIONING (HVAC) EQUIPMENT SHALL BE RATED AND MARKED "HACR ", IF FUSING IS NOT PROVIDED AT PIECE OF HVAC EQUIPMENT. FIELD VERIFY EXACT HACR BREAKER REQUIREMENTS WITH HVAC EQUIPMENT NAMEPLATE AND MANUFACTURER'S REQUIREMENTS PRIOR TO INSTALLATION. 9. IN SERVICE ENTRANCE APPLICATIONS, PANELS SHALL BEAR THE MANUFACTURER?S LABEL INDICATING THE EQUIPMENT IS RATED FOR "SERVICE ENTRANCE" APPLICATION IN ACCORDANCE WITH THE NEC AND AS INDICATED ON DRAWINGS. 10. AFTER COMPLETION, ALL PANELBOARDS SHALL BE CLEANED BOTH INSIDE AND OUTSIDE. 11. PANELBOARDS SHALL BE EATON, G.E., SQ -D, OR SIEMENS. M. DRY TYPE TRANSORMERS 1. PROVIDE DRY TYPE TRANSFORMERS FOR THE DISTRIBUTION SYSTEM AT LOCATIONS SHOWN ON THE DRAWINGS. TRANSFORMERS SHALL HAVE KVA AND VOLTAGE RATINGS AS INDICATED ON THE DRAWINGS. 2. 120/208 VOLT 3- PHASE, 4-WIRE WYE SECONDARY TRANSFORMER SHALL HAVE 480 VOLT, 3- PHASE, 3 -WIRE DELTA PRIMARY, 60 HERTZ. 3. TRANSFORMER SHALL BE QUIET TYPE CONSTRUCTION AND HAVE SIX (6) 2 1/2% TAPS, TWO (2) ABOVE AND FOUR (4) BELOW NOMINAL PRIMARY RATING. SOUND LEVELS MUST FALL WITHIN ASA -NEMA STANDARD LEVELS ACCORDING TO KVA SIZE. ALL TRANSFORMERS SHALL BE UL LISTED WITH VENTILATED HOUSINGS AND STANDARD FULL TEMPERATURE RISE 150 DEGREE CELSIUS CLASS "H" INSULATION. 4. TRANSFORMERS SHALL BE SECURELY MOUNTED FROM THE BUILDING STRUCTURE, REINFORCED WALLS, OR AS NOTED ON DRAWINGS. USE ADDITIONAL VIBRATION ISOLATORS AT POINTS OF MOUNTING TO CUT VIBRATION NOISES. USE FLEXIBLE CONDUIT ON PRIMARY AND SECONDARY FEEDS OF THE TRANSFORMERS. TRANSFORMERS SHALL BE LOCATED, SET, MOUNTED AND CONNECTED IN SUCH A MANNER TO KEEP NOISE LEVELS WITHIN THE SURROUNDING AMBIENT NOISE LEVELS AND MAINTAIN ALL CODE REQUIRED CLEARANCES. (PROVIDE SEISMIC SUPPORTS AS REQUIRED BY LOCAL CODES) 5. TRANSFORMERS SHALL BE EATON, G.E., SQ -D, OR SIEMENS. N. LIGHTiNG FIXTURES & LAMPS 1. THE GENERAL CONTRACTOR SHALL INSTALL ALL UGHTING FIXTURES AND LAMPS AS SHOWN ON THE DRAWINGS. 2. ALL RECESSED INCANDESCENT FIXTURES SHALL BE PROVIDED WITH APPUCABLE THERMAL PROTECTION. 3. WHERE FLUORESCENT FIXTURES ARE SPECIFIED, THEY SHALL BE PROVIDED WITH HIGH POWER FACTOR RAPID START BALLASTS, U.L LISTED, C.B.M. CERTIFIED, AND E.T.L APPROVED WITH EFFICIENCY FACTORS IN ACCORDANCE WITH THE "NATIONAL APPUANCE ENERGY CONSERVATION ACT OF 1987" AND AMENDMENTS. 4. GENERAL CONTRACTOR SHALL FURNISH ADDITIONAL AUXILIARY SUPPORTING STEEL HANGER WIRES ADEQUATELY SIZED TO SUPPORT THE WEIGHT OF THE FIXTURE AND FASTENED TO BUILDING STRUCTURE (MINIMUM TWO PER FIXTURE) FOR FIXTURES NOT MOUNTED ON BUILDING FRAMEWORK. FIXTURES SHALL NOT BE SUPPORTED SOLELY BY THE FINISHED CEILING STRUCTURE. 5. GENERAL CONTRACTOR SHALL VERIFY THE MODEL NUMBERS AND QUANTITY OF ALL LAMPS AND FIXTURES PROVIDED BY THE TENANT. CONTACT TENANT PROJECT MANAGER IMMEDIATELY IF THE MODELS DIFFER FROM THOSE USTED ON THE LIGHTING FIXTURE SCHEDULE OR IF THEY DO NOT HAVE PROPER THERMAL PROTECTION. 6. PROVIDE APPLICABLE FIRE RATED DRYWALL BOXES OVER RECESSED FIXTURES IN FIRE RATED CEIUNGS AS REQUIRED BY CODES. FIELD COORDINATE AS REQUIRED TO AVOID CONFLICTS. 7. GENERAL CONTRACTOR SHALL PROVIDE ANY NECESSARY FITTINGS, ACCESSORIES, ETC. AS NECESSARY TO MAKE A COMPLETE INSTALLATION. 8. REMOVE ALL DIRT, OIL OR GREASE FROM UGHT FIXTURES. CLEAN ALL GLASS, LENSES, ETC. AND POUSH FIXTURES AND TRIM. 9. INSTALL ALL SAFETY CABLES FOR TRACK LIGHTS AS REQUIRED. CABLES TO BE SUPPLIED BY THE DISNEY STORE AND INSTALLED BY G.C. 0. LIGHTING CONTACTORS AND TIME SWITCHES 1. WHERE INDICATED ON THE DRAWINGS, CONTACTORS FOR CONTROL OF SHOW WINDOW LIGHTING AND SIGNS SHALL BE SQUARE D CLASS 8903, TYPE 'LX' IN A NEMA 1 ENCLOSURE, ELECTRICALLY OPERATED, AND MECHANICALLY HELD. NO EXCEPTIONS. TIME SWITCHES FOR CONTROL OF SHOW WINDOW LIGHTING AND SIGNS SHALL BE TORK MODEL DGM -100, 7 DAY TYPE IN NEMA TYPE 1 ENCLOSURE. 2. GENERAL CONTRACTOR TO VERIFY STORE OPEN AND CLOSE TIMES. TIME CLOCKS TO BE SET TO TURN ON 60 MINUTES BEFORE OPENING AND OFF 60 MINUTES AFTER CLOSING. P TELEPHONE DATA AND COMPUTER WIRING 1. PROVIDE A SYSTEM OF CONDUIT RACEWAYS, OUTLET BOXES, PULL WIRES, AND TERMINAL BOARDS AS SHOWN ON THE DRAWINGS. TELEPHONE SWITCHING APPARATUS, CONDUCTORS, INSTRUMENTS, MISCELLANEOUS EQUIPMENT AND APPURTENANCES ARE NOT PART OF THIS CONTRACT AND WILL BE PROVIDED AND INSTALLED BY THE DISNEY STORE. 2. OUTLET BOXES TO BE 4" SQUARE MINIMUM WITH SINGLE DEVICE COVER AND TELEPHONE PLATE. 3. CONDUIT RUNS FROM TELEPHONE BOARD OR MANAGER'S OFFICE FOR TELEPHONE AND DATA ONES TO CASHWRAPS ARE TO BE CONTINUOUS WITH NO JUNCTION BOXES. 4. ALL PULL WIRES ARE TO BE LABELED FOR PURPOSE DESIGNATED. Q. IDENTIFICATION 1. ALL SWITCHGEAR, CIRCUIT BREAKERS AND DISCONNECTS IN SWITCHGEAR, PANELBOARDS, TRANSFORMERS, TIME CLOCKS, THERMAL OVERLOAD FAN SWITCHES, EQUIPMENT CONTROL SWITCHES, SAFETY SWITCHES, MOTOR STARTERS, AND SIMILAR ITEMS SHALL BE IDENTIFIED BY NAME, FUNCTION, AND /OR CONTROL NAMEPLATES SHALL BE AT LEAST 1" X 3" WITH CHARACTERS NOT LESS THAN 1/4 ". THEY SHALL BE MADE UP OF PLAS11C- LAMINATED TAGS AND CHARACTERS ENGRAVED TO ENGRAVER'S STANDARD THCKNESS AND LETTER STYLE WIN WHITE CORE AND BLACK BACKGROUND. NAMEPLATES SHALL BE FASTENED TO EQUIPMENT WITH HEAVY DUTY INDUSTRIAL GRADE CONTACT CEMENT. 2. PROVIDE TYPED DIRECTORIES IN PANELBOARDS TO DEPICT ACTUAL EQUIPMENT CONNECTED TO INDIVIDUAL BREAKERS /SWITCHES. R. TESTS AND ADJUSTMENTS 1. ALL CONNECTONS AT PANELS AND SWITCHES ARE TO BE MADE, ALL SPUCES COMPLETE, ALL FUSES IN PLACE, AND ALL CIRCUITS CONTINUOUS FROM POINT OF SERVICE CONNECTION TO ITS FINAL DESTINATION, AND ALL COVERS AND PLATES INSTALLED PRIOR TO TESTING. 2. UPON COMPLETION OF THE WORK, ALL PARTS OF THE ELECTRICAL INSTALLATION SHALL BE TESTED AND PROVED FREE OF UNWANTED GROUNDS AND OTHER DFECTS. 3. ALL OVERLOAD DEVICES, INCLUDING EQUIPMENT FURNISHED UNDER OTHER CONTRACTS, SHALL BE SET AND ADJUSTED TO SUIT THE LOAD CONDITIONS. 4. TEST AND MAKE CORRECTIONS /ADJUSTMENTS FOR PHASE BALANCING. 5. PROVIDE AIMING /ADJUSTMENT OF ALL ADJUSTABLE UGHT FIXTURE HEADS PER CONSTRUCTION DOCUMENT REQUIEMENTS AND PER ARCHITECT/ PROJECT MANAGER'S INSTRUCTIONS. S. INSTRUCTIONS 1. AFTER ALL TESTS AND ADJUSTMENTS HAVE BEEN MADE, THE GENERAL CONTRACTOR SHALL FULLY INSTRUCT THE REPRESENTATIVES OF THE DISNEY STORE IN ALL DETAILS OF OPERATION AND MAINTENANCE OF THE EQUIPMENT INSTALLED UNDER THIS CONTRACT. INSTRUCTION SHALL BE FURNISHED UNTIL TDS IS SATISRED. FURNISH THE DISNEY STORE WITH TWO INSTRUCTION MANUALS ON EACH SYSTEM. INSTRUCTION MANUALS SHALL CONTAIN ALL SHOP DRAWINGS, MANUFACTURERS INSTALLATION AND OPERATION INSTRUCTIONS, GUARANTEES, MAINTENANCE SCHEDULE, ETC. T. CLEANING 1. AT THE END OF THE PROJECT, THE GENERAL CONTRACTOR SHALL CLEAN ALL EQUIPMENT, INCLUDING UGHT FIXTURES, TO THE SATISFACTION OF THE DISNEY STORE PROJECT MANAGER. ALL DUST, DIRT, DEBRIS AND FOREIGN MATTER SHALL BE RENOVED FROM ALL EQUIPMENT. REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC MAY 3 1 2011 City of Tukwila BUILDING DIVISION ELECTRICAL GENERAL NOTES: SYMBOLS 1. PRIOR TO SUBMITTING BID, THE GENERAL CONTRACTOR SHALL VISIT THE JOB SITE AND FULLY ACQUAINT HIMSELF WITH THE EXISTING CONDITIONS OF THE PROJECT. THE GENERAL CONTRACTOR SHALL BE REPSONSIBLE FOR REVIEW OF ALL GENERAL NOTES, SPECIFICATIONS AND ALL OTHER CONSTRUCTION DOCUMENTS FOR ADDITIONAL REQUIREMENTS WHICH MAY NOT BE SPECIFICALLY CALLED OUT IN THIS PORTION OF THE CONSTRUCTION DOCUMENTS. NOTIFY CONSTRUCTION MANAGER OF ANY CONFLICTS OR DISCREPANCIES PRIOR TO SUBMISSION OF BID. 2. THE LOCATION OF THE SERVICE TERMINATIONS SHALL BE DETERMINED IN FIELD. CONTRACTOR TO VERIFY SERVICE CONNECTIONS INCLUDING ALL NECESSARY PULL BOXES, SIZE AND NUMBER OF CONDUITS AND CONDUCTORS, SWITCHGEAR, METERING, CABLE CHARGES, ETC., WHETHER SHOWN ON DRAWINGS OR NOT, BUT REQUIRING SERVICING UTILITY COMPANY TO MAKE A COMPLETE AND OPERABLE ELECTRICAL SERVICE. 3. FURNISH AND INSTALL ALL TELEPHONE CONDUITS AS SHOWN ON DRAWINGS. PROVIDE PULLSTRINGS IN ALL CONDUITS. 4. WHENEVER ANY ELECTRICAL WORK PIERCES ANY WATERPROOFING, IT SHALL BE INSTALLED IN A WATERPROOF MANNER, USING WATERPROOF EQUIPMENT. 5. CONTRACTOR SHALL FURNISH AND INSTALL PULLSTRINGS IN ALL EMPTY CONDUITS. 6. GENERAL CONTRACTOR SHALL INCLUDE ALL MATERIALS AND COSTS ASSOCIATED WITH CONNECTION AND INSTALLATION OF THE "BMS" AND LIFE SAFETY SYSTEMS. RESPONSIBILITY REFER TO SHEET T1.0 FOR RESPONSIBILITY MATRIX FOR ELECTRICAL COMPONENTS ABBREVIATIONS A AM AFF ABOVEEFINISHED FLOOR CB CIRCUIT BREAKER CO CONDUIT ONLY DD DUCT DETECTOR DE DU DIS EMENT ING EC EACH EQPT EQUAL GC GENERAL CONTRACTOR GFCI GROUND FAULT CIRCUIT INTERRUPTER G GND GROUND HID HORSEPOWER IC INTERRUPTING CAPACITY (RMS SYM.) IG ISOLATED GROUND LT LIGHT MFR MANUFACTURER MINX MINIMUM NA NOT APPLICABLE NTS NOT TO SCALE NIC NOT IN CONTRACT NL NIGHT E LIGHT REED PROPERTY Q LINE REQMNT REQUIREMENT RGC RIGID GALVANIZED CONDUIT SCA SIMILAR CIRCUIT AMPERE SIM SLD TWBRD TBB %G U UL VON VL WP SINGLE LINE DIAGRAM SWITCH SWITCHBOARD TRANSFORMER TELEPHONE BACKBOARD TYPICAL UNDERGROUND UNDERWRITER S LABORATORIES UNLESS OTHERWISE NOTED VOLT VOLT AMPERE VERIFY LOCATION WATT WEATHERPROOF FILE COPY Permit k Phn review approval is subject to errors and omIs stone. kpp cevai of construction documents does not authorize Vic violation of any adopted code or ordinance. Receipt of approved Fieid and oor sons aty Of ltdavila BUILDING DIVISION REVISIONS No chances shall b e made to the scope of work without prior approval of Tukwila Building Division. Nr4T :: Revisions will require a new plan submittal and may include additional plan review fees. SEPARATE PERMIT REQUIRED FOR: ErMechanicai ❑ lectricai Lr Plumbing CASs Piping City of Tukwila Bull DING DIVISION FLOOR 0 Zi W U J < DESCRIPTION 0-1 6-a LIGHT FIXTURE AS SPECIFIED, SUBSCRIPTS WHEN INDICATED DENOTE BRCH CKT /SW LEG a� s mil s EXIT SIGN, SINGLE FACE, ARROW IF INDICATED DENOTES DIRECTION FLUORESCENT LIGHT FIXTURE AS SPECIFIED `.M 1 0 s SINGLE POLE TOGGLE SWITCH @+48 "(UNLESS OTHERWISE NOTED) SUBSCRIPTS INDICATE THE FOLLOWING: a- OUTLET 'a' CONTROLLED 3 -THREE WAY D- DIMMER, RATING AS NOTED M- MANUAL MOTOR STARTER P -PILOT ON LIGHT oppi DUPLEX RECEPTACLE, WALL @+15 "(UNLESS OTHERWISE NOTED) r SPECIAL RECEPTACLE, TYPE AS NOTED ON PLANS 0 a JUNCTION BOX, SIZE AS NOTED AND PER CODE ■ TELEPHONE OUTLET, WALL @+15 "(UNLESS OTHERWfSE NOTED) > - DATA OUTLET PHONE AND DATA OUTLET • ELECTRICAL EQUIPMENT AS NOTED ON PLAN CJ DISCONNECT SWITCH:30A /1 -POLE, NON -FUSED (UON) ®.J COMBINATION OF MOTOR STARTER AND CIRCUIT BREAKER, NEMA SIZE '0' (LION) 0 CONDUIT TURNING UP CONDUIT TURNING DOWN CONDUIT CONCEALED IN CEILING OR WALL, 1/2" CONDUIT, 2 #12 WIRES (LION) CROSS LINES DENOTE NO. OF #12 WIRE, SIZE CONDUIT PER CODE AND AS NOTED ON PLANS 2LA 1 -3 `> HOMERUN TO PANEL 2LA CIRCUITS 1 & 3 CONDUIT `CONCEALED IN FLOOR SLAB DR �INDERGROUND CONDUIT EXPOSED CONDUIT STUB WITH CAP, SIZE AS NOTED GROUND, PER CODE AND AS SPECIFIED 150A/3 - CIRCUIT BREAKER, 150A, 3 -POLE - � -I I I � SWITCH & FUSE, 100AS, 75AF, TYPE AS NOTED, 100AS /75AF 3 -POLE (LION) co UTILITY METERING 4 A SURFACE MOUNTED PANELBOARD: PANEL "A" FLUSH MOUNTED PANELBOARD r A SWITCHBOARD MIN TRANSFORMER © REFERENCE TO DETAIL #2 ON SHEET E5 0 MOTOR NOTE: THIS IS A GENERAL SYMBOL LIST, SOME ITEMS MAY NOT APPLY TO THIS PROJECT. FIRE ALARM NOTE SHELL BUILDING HAS BEEN PROVIDED WITH FULLY AUTOMATIC LIFE SAFETY FIRE ALARM (LSFA) SYSTEM. LSFA SYSTEM IN THE TENANT SPACE SHALL BE PROVIDED AS A DESIGN -BUILD PACKAGE. IT SHALL BE RESPONSIBLITY OF THE G.C. TO ENGAGE SERVICES OF A CONTRACTOR APPROVED BY THE BUILDING MANAGEMENT TO PROVIDE (LSFA) SYSTEM FOR THE DISNEY STORE PROJECT. ALL WORK SHALL BE IN FULL COMPLIANCE WITH THE LANDLORD REQUIREMENTS AS WELL AS LOCAL AUTHORITIES. REVISION N0. MAY - 5011 I 1 1 � 0�I PERMIT 2 GE2NTER � Linane /Drews Architects 3500 West Burbank Blvd Second Floor Burbank, CA 91505 818.972.5080 818.848.3895 Fax All information shown or described herein is the property of Llnane / Drews Architects, Incorporated; and shall not be reused, copied, or reproduced in any form without the express written authorization of Linane / Drews Architects, Incorporated. © Copyright: Linane /Drews Architects, Incorporated 2011 All rights reserved. dp DON PENN CONSULTING ENGINEER 835 WESTPORT PARKWAY, SUITE 300 GRAPEVINE TEXAS 78051 817 - 410 -2818 FAX 817 -251 -8411 ISSUED FOR: DATE PRE BID /BLDG. DEPT. SUBMITTAL 03.25.11 BID /LL FINAL REVIEW 04.08.11 CONSTRUCTION SET 05.17.11 No. REVISION ISSUES: DATE WESTFIELD SOUTHCENTER SPACE # 592 536 SOUTHCENTER MALL TUKWILA, WA 98188 STORE NUMBER: 357 Drawn By DM A/E Job Number 1D1102.00 Checked By KG Fie Name TD1102_E10 Project Mgr. DM Scale: Title: ELECTRICAL SPECS, SYMBOLS & NOTES Sheet No. E1..O TD1102_E10 PLOT DATE: 5.18.2011 NEW PANEL LB Service: 1201208 Volts 3 Phase 4 Wre Cabinets: Surface Mounted MAIN: 250 Amp MCB; 250 Amp NEMA 1 REM CKT DESCRIPTION WATTS WIRE BKR AIB BKR WIRE DESCRIPTION WATTS CKT' REM 8 1 DRINKING FOUNTAIN 900 12 1/20 X 1/20 12 POS RECEPTACLES 720 ' 2 38o PROCESS AREA RECEPTS DED. PROCESS RECEPT ......................0 3 CAST AREA RECECPACLE 360 12 1/20 + 1120 12 SENSORMATIC 400 4 DST RECEPTACLE 600 5 MONITOR 500 12 :1/20 12 BOYS HERO FIXTURE 1130 10 TNSTA -HOT 2400 6 500 g 7 LIGHTING OVE 1 900 12 1120 2:l(i :Ts X 2/40 8 INSTA -HOT 4450 • 6 7 9 c, 400 12 1/20 1/20 SALES TRACK LTG 4450 10 ; 14 11 ACCESS POINT RECUR 500 12 1/20 '1/20 1 /?O 12 POS 604 12 1120 18 13 POS 800 12 1120 X 1/20 12 STOCKROOM RECEPTS 540 14 MG 14 15 POS 900 12 : 1120 + 1/20 12 em Kt_CtP"IS 960 16 21 REFRIGERATOR 17 AN ROOM 600 12 1120. 12 1130 12 CABINET' RECEPTACLE 360 18. SPARE 1200 19 AN RACK 400 10 :1/30 X 1/20 12 MANAGER RECEPTALLES 360 20 200 12 21 MANA',iER RECEPTACLE 360 12 1120 + 1/20 12 TELEPHONE BOARD 400 22 SPACE 1/20 23 . • ' ... - 500 12 ', 1/20 30 1/20 12 " _. . ` 720 25 AN RACK 400 12 1/20 X 1/20 12 WINDOW MONITOR 200 1120 X ■• pa 27 AN RACK 400 12 1/20 : + 1/20 12 CAST AREA COMPUTER 500 28 6 29 EM MODULE 500 12 1/20 ®e 1/20 12 MICROWAVE 600 311 8 '1/20 31 PANEL LD i 3P /60 X STOCK ROOMLIGHTING PANEL LA 5887 2 380 5310 + 3P/60 5660 34 33 5520 i'N*Tr11m:ifIP►r+i 5716 36 38 4,5 37 RTU -1 . 4590 3P /80 X '' + I 3/20 12 SURGE SUPPRESSOR 100 38 31;0 45£0 100 40 39 4500 3 X 100 42 41 TOTAL LOAD PHASE 'A' 25097 REMARKS TOTAL LOAD PHASE 'B' 23890 1 PROVIDE CFCI BREAKER TOTAL LOAD PHASE 'C' 23206 2 CIRCUITViA TIMECLOCK 3 CIRCUiT VIA LIGHTKEEPER TOTAL LOAD ALL PHASES 72193 WATTS 4 PROVIDE BREAKER & FUSES PER EQUIPMENT 20054 AMPS MANUFACTURERS RECOMMENDATION. 5 PROVIDE SWr1tH RATED BREAKERS. 0 24 HOUR CIRCUIT (PROVIDE A LOCK ON DEVICES) 7 CIRCUIT iiIA TRACK KEEPER NEW PANEL LD Service: 120/208 Volts 3 Phase 4 Wire Cabinets: Surface Mounted Main: 100 Am' MLO 1 - - CKT DESCRIPTION WAITS WA. WIRE BKR . C —. -7 s Y _ _ WA CKT 4 REM HAND DRYER 1600 12 1120 1 /20 no SPARE 1120 13770 F . 1111 :C Cilllil;ii7:% 38o PROCESS AREA RECEPTS DED. PROCESS RECEPT ......................0 720 12 12 1/20 1120 + 1/20 1/20 12 SPARE RIDE MAKER 500 4 6 1120 12 DST RECEPTACLE 600 12 1120 1120 1120 1/20 12 BOYS HERO FIXTURE 350 8 ALE TRA K LI HTIN LIGHTING COVE 2 9 jlslil il1 1 f. 500 g 12 ge 1/2.0 12 2:l(i :Ts 350 10 Z5 1120 + • 120 7 � . LES TRACK LIGHTING 14 1/20 �s 1/20 SALES TRACK LTG r (IC MIIRROR 200 14 12 15 SPARE 12 Z4 '1/20 111 1/20 LA -18 ANTENNA 12 1120 18 17 A ROOM REL:EPTAC;LE N 3150 PERIMETER TRACK LTG 1/20 LA -31 1120 12 RF I 300 18 MG 14 12 1/20 LD -12 1 Lm /20 12 • ° 360 1E SPARE 21 REFRIGERATOR 540 L' 1/20 BEI 1/20 12 ' 1500 22 12 25 SPARE 1200 BEEN 1/20 1/20 NM 1/20 12 l+1 %:"Till SIW °E ^ACLE 1500 1500 26F 2 — 27 INTRUSION PANEL 200 12 1120 + 1/20 12 /Vi/ RECEPTACLE 1500 28 2 30 29 SPARE — SPACE 1/20 — X 1/20 480 SPARE 2 30 REMARKS 1 PROVIDE GFCI BREAKER 2 CIRCUIT VIA TIMECLOCK 3 CIRCUIT ViA LIGHTKEEPER 4 PROVIDE BREAKER & FUSES MANUFACTURERS RECOMME 5 PROVIDE SWITCI I RATED DR 9 24 HOUR CIRCUIT (PROVIDE A PER EQUIP NDAT ION. EAKC G. LOCK ON DEVICES) ENT TOTAL LOAD PHASE 'A TOTAL LOAD PHASE 'B' TOTAL LOAD PHASE "C' TOTAL LOAD ALL PHASES 5550 5310 5520 10350 WATTS 45.50 AMPS NEW PANEL LA Service: 120/208 Volts 3 Phase 4 Wire Cabinets: Surface MoLnted Main: 100 Amp MLO NEMA 1 REM CKT DESCRIPTION WAITS WIRE BKR A B C BKR WIRE DESCRIPTION WATTS CKT REM 7 Ei 1 4`31:7T rfirti'T min 360 1500 11300 no 14125 1120 13770 F . 1111 :C Cilllil;ii7:% 38o ©pa 4 WM Ma IIIII 7 7 7 3 SALES TRACK LIGHTING �i`;I'inEi 31 2113CtT: ii cT 1 0 SALES TRACK LIGHTING 240 I® 1120 ■©■ LA -13 Z5 1120 12 SALES TRACK LIGHTING 240 120 240 KEIIII 12 1120 1120 1111111111113 ©■■ LA -17 Z4 1/20 1/20 12 ALE TRA K LI HTIN LIGHTING COVE 2 240 1090 a 8 10 7 .. .- ` -7. " I LA -2 240 12 1 /20 12 LA-4 Z5 1120 12 ' L . -�"` K. c H 120 7 120 V . LES TRACK LIGHTING 14 240 12 11211 SALES TRACK LTG 15 LA -12 1120 12 SALES TRACK LIGHTING ?40 12 Z4 7 PERIMETER TRACK LTG :• LES TRACK. LIGHTING LA -18 380 12 1120 18 LA -22 Z4 1/20 PERIMETER TRACK LTG SPARE LA -31 14 120 V 7 20 v ` LES 'TRACK LIGH MG 480 12 1/20 LD -12 Z5 120 V 1.120 12 SALES I' HACK UGH IING 360 1E SPARE 7 — - . 1; - L' 240 12 1/20 — — SPARE 1.120 12 SALES TRACK LiGH11NC3 240 1E 26 9 19 •J'1 , r ' G " 123 27 1120 ��.1120 — SPARE 1./20 111 ' -1 — HIM 29 — 21 ` -` 500 30 1/20 — — SPACE 31 — SALES TRACK LIL'HIING 480 7 2 — 2 — SPACE BR . 1120 X ■• pa PROJECTOR 1120 (LARGE) 1100 1216 ®e 20 PROJECTOR (SMALL) 1100 '1/20 mop 1/20 STOCK ROOMLIGHTING 2 EivITi'1boivi'ime -:lira 380 1/20 ©■■ 1120 110311 i'N*Tr11m:ifIP►r+i ®© 34 0 1/20 ■©■ 1/20 ®V'IL"+►1:14aKe1'lis ti: 1`Trm 31;0 ® R4! +M LI HT1Ne 60 1120 * ■U" 1120 111811L122=ILIZIZIMIIIIIIN 320 M© 38 © PROJECTOR (SMALL) 11CHCJ 12 1/20 a ■■ 1/20 12 TOILET LIS /FANS 1 39 SPARE 1/20 X 1120 12 PROJECTOR (LARGE) 1100 4C 41 PROJECTOR (SMALL) "1100 12 1/20 X 120 12 LIGHTING COVE 2 360 42 TOTAL LOAD PHASE 'A' 5E87 REMARKS TOTAL LOAD PHASE 'B' 5190 1 PROVIDE GFCI BREAKER TOTAL LOAD PHASE 'C' 5716 2 CIRCUIT VIA TIMECLOCK 3 CIRCUIT VW CONTROL KEEPER TOTAL LOAD ALL PHASES 177093 WATTS 4 PROVIDE BREAKER & FUSES PER EQUIPMENT 4740 AMPS MANUFACTURERS RECOMMENDATION. 5 PROVIDE SWITCH RATED BREAKERS. 0 24 HOUR CIRCUIT IPROVIDE A LOCK CN DEVICES; 7 CIRCUIT VW TRACK KEEPER ELECTRICAL LOAD SUMMARY PANEL 120/208V 3 PH - 4W LOAD DESCRIPTION CONNCCTID LOAD (WATTS) -DEMAND FACTOR. DEMAND LOAD (WATTS) DEMAND LOAD (AMPS) LIGHTING 8023 1.25 10029 2 RECEPTACLES 37900 NOTE #1 23950 SIGNS 1200 1.25 1500 WATER HEATERS 11300 1.25 14125 A/C EQUIPMENT 13770 NOTE #2 16020 TOTAL 72193 — 65624 162 NOTES: 1. 100% OF FIRST 1C,000 WATTS , PLUS 50% OF REMAINING LOAD. 2.. 100% OF A/C LOAD, PLUS 25% OF HIGHEST LOAD. CONTROL KEEPER - COOPER CKT-32 Relay # Line Circuit Zone Volt Description 1 LA-1 Z4 120 V PERIMETER TRACK LTG 2 LA-3 Z4 120 V PERIMETER TRACK LTG 3 LA-5 Z5 120 V SALES TRACK LTG 4 LA-7 Z5 120 V SALES TRACK LTG 5 LA-9 Z3 120 V STOREFRONT TRACK SALES TRACK LTG 6 LA -11 Z5 120 V 7 LA -13 Z5 120 V SALES TRACK LTG 8 LA -15 Z4 120 V PERIMETER TRACK LTG 9 LA -17 Z4 120 V PERIMETER TRACK LTG 10 LA -23 Z5 120 V SALES TRACK LTG 11 LA -2 Z5 120 V SALES TRACK LTG 12 LA-4 Z5 120 V SALES TRACK LTG 13 LA-6 Z4 120 V PERIMETER TRACK LTG 14 LA -10 Z5 120 V SALES TRACK LTG 15 LA -12 Z5 120 V SALES TRACK LTG 16 LA -16 Z4 120 V PERIMETER TRACK LTG 17 LA -18 Z4 120 V PERIMETER TRACK LTG 18 LA -22 Z4 120 V PERIMETER TRACK LTG 19 LA -31 Z3 120 V STOREFRONT LTG 20 LD -23 Z3 120 V SIGNAGE 21 LD -12 Z5 120 V CHANDELIER 22 — — — SPARE 23 — — — SPARE 24 — — — SPARE 25 — — — SPARE 26 — — — SPARE 27 — — — SPARE 28 — — — SPACE 29 — — — SPACE 30 — — — SPACE 31 — — — SPACE 32 — — — SPACE TRAC KEEPER- COOPER TK-32 Breaker # Line Circuit Limit Rating (Amps.) 1 LA-1 3 2 LA-3 2 3 LA-5 1 4 LA -7 2 5 LA -9 2 6 LA -11 2 7 LA-13 3 8 LA -15 4 9 LA -17 2 10 LA -23 2 11 LA -2 3 12 LA-4 2 13 LA-6 2 14 LA-10 1 15 LA -12 2 16 LA -16 3 17 LA -18 2 18 LA-22 4 19 SPARE 20 SPARE 21 SPARE 22 SPARE 23 SPACF 24 SPACE 25 SPACE 26 SPACE 27 SPACE 28 SPACE 29 SPACE 30 SPACE 31 SPACE 32 SPACE ZONE ZONE NAME Z1 ALL ON Z2 ALL OFF Z3 STOREFRONT /SIGN /GOBO Z4 PERIMETER TRACK Z5 SALES TRACK NOTE: IT IS THE ELECTRICAL NT CO RACTORS RESPONSIBILITY TO PROPERLY BALANCE ALL BRANCH CIRCUITS BETWEEN THE PHASES OF THE SYSTEM. REGARDLESS OF THE CIRCUITING INDICATED. t>1Q�i ALL 1RAGK LIMNS TO ER GONEGIED TO 119E CURRENT utirmt MAO KEEFEt FROM 1IE LIFE KEEPER GONiROL 5195181, PANEL RISER DIAGRAM 120/208V 3 PH, 4 WIRE ELECTRICAL SERVICE NOTE: TENANT'S ELECTRICAL CONTRACTOR SHALL FURNISH AN IDENTIFICATION NAMEPLATE ON TENANT'S MAIN DISCONNECT SWITCI4 IN LL'S METER SECTION. NAMEPLATES SHALL BE Xs' THICK PLASTIC, BLACK ON WHITE AND ETCHED LETTERS. THE MINIMUM SIZE SHALL BE 1' WITH ONLY THE TENANT'S SPACE " ENGRAVED AND IS PERMANENTLY AFFIXED- ELECTRICAL KEYNOTES ® PROVIDE PERMANENT LABEL TO READ `DISNEY STORE ". ® 2 "C.O. STUB —OUT INTO TENANT SPACE, VL. G.C. TO INTERCEPT 2 "CONDUIT AND EXTEND WITH SAME TO NEW PANEL "HA ". G.C. TO PROVIDE WIRES AS SHOWN IN ENTIRE LENTH OF CONDUIT; FROM LANDLORD'S SWITCHBOARD TO NEW PANEL "HA ". 03 200A METER /MAINS. ® FEEDER DISTANCE PER AS —BUILT OR TO BE FIELD VERIFIED. ® NEW PANEL TO BE PROVIDED AND INSTALLED BY G.C., SEE PANEL SCHEDULE THIS SHEET FOR INFO. ® 'HACR' RATED CIRCUIT BREAKER SIZE PER ROOF —TOP UNIT'S NAMEPLATE DATA. ® SIZE BRANCH CIRCUIT CONDUIT /WIRES PER CODES AND PER RTU'S LOAD REQUIREMENTS. GROUND WIRE MUST BE INCLUDED IN THE CONDUIT. ® PROVIDE WEATHERPROOF FUSED DISC. PER UNIT'S NAMEPLATE DATA. FUSES MUST BE RK5 —DE. ® PROVIDE 2— GANG /WP J —BOX ON 6 "- 3/4 "C.O. STUB NEAR TO ROOF —TOP FOR CONTROL CABLE. IO PROVIDE DUPLEX RECEPTACLES /WP ON 6 " -3/4 "C STUB NEAR TO ROOF —TOP. EXTEND 3/4 " -3 #12 WIRES TO PANEL "LB ". IMPORTANT: G.C. TO PROVIDE ALTERNATE BID FOR INCREASE OF SERVICE TO 250 AMPS. BID TO INCLUDE (BUT NOT LIMITED TO) PROVIDING OF NEW FEEDERS, CONDUIT, AND BREAKERS BACK TO LL SWITCHGEAR. r L (LL) AREA w J w 1n w J DISNEY SPAGE (4) #250 THWN,� (1) #2 GND IN EXISTING 2 -1/2 "C APPROXIMATELY 115' 2O8V,30,411 _j (E) LANDLORD'S SHITGHBOARD (4) #250 THWN, (1) #2 GND IN 2-1/2"C 803 603 II LIGHTING CONTROL PANEL, CONTROL KEEPER CK -32. PANEL PROVIDED BY OWNER INSTALLED BY GENERAL CONTRACTOR. SEE SHEET E1.3 FOR WIRING DIAGRAMS. 12 BRANCH CIRCUIT WIRING PER LIGHTING PLANS. SEE SCHEDULE ON E1.1. 13 CURRENT LIMITING PANEL: TRACKEEPER TK -32. SEE SCHEDULE ON E1.1 FOR CURRENT LIMITING AMP SIZES AND SHEET E1.3 FOR WIRING DIAGRAMS. 14 SURGE SUPPRESSION PROTECTION FOR PANEL "LB" 120/208V, 30, 4W +GND, WYE SURGEFREE 120M. MOUNT NEAR PANEL "LB ". 15 PER NEC 310.15(B)(2)(A) ADJUSTMENT FACTORS FOR MORE THAN THREE CURRENT — CARRYING CONDUCTORS IN A RACEWAY OR CABLE THE 23 CONDUCTORS THAT GO THROUGH THE TRAC KEEPER — COOPER CURRENT LIMITING PANEL SHALL BE IN A IN 1 -1/4' CONDUIT WITH #8G. THESE SHALL BE LOADED NO MORE THAN 45% OF THE 25A THAT THE WIRE (THWN) IS RATED AT. THE CURRENT LIMITERS FOR EACH CIRCUIT LIMIT THE CURRENT TO 2A, WHICH SATISFIES THIS REQUIREMENT. THE REMAINING CIRCUITS THAT GO THROUGH THE LIGHTING CONTROL PANEL (BUT NOT THROUGH THE TRAC KEEPER — COOPER CURRENT LIMITING PANEL) SHALL BE INSTALLED IN THREE " PARALLEL CONDUITS WITH NO MORE THAN 6 CURRENT CARRYING CONDUCTORS EACH. USE #6G IN EACH is CONDUIT. THE 20A CIRCUIT BREAKERS AT THE PANEL WILL BE LOADED AT NO MORE THAN 80% OF 25A (OR 20A), WHICH SATISFIES THE REQUIREMENT OF NEC 310.15(B)(2)(A). 16 #8 CU GROUND TO BUILDING STEEL AND WATER PIPING PER L.L. /NEC. 250 REQUIREMENTS I.7 IOTA ITS -375 -1 INVERTER. ABLE TO PROVIDE 375 WATTS OF CONTINUOUS POWER FOR 90 MINUTES. LOAD FOR EMERGENCY LIGHTS IN SALES AREA IS 257 WATTS ON CIRCUIT LA -21. p® (ROOF -TOP UNIT) (3) #3 THWN, (1) #6 GND IN 1 -1/4 "C (4) #1 THWN, (1) #8 GND IN 1"C L1 PANELBOARD 543 3/10 PANELBOARD (1) #12 THWN (1) #8 GRND IN 3/4" CONDUIT TO EMERGENCY LIGHTS PANELBOARD LA LMERGENCY LIGHTING ° INVERTER (4) #12 THWN, (1) #12 GND IN 1/2"C SURGE SUPPRESSOR 14 (4) #1 THWN, (1) #8 GND IN 1 "C LIGHTING CONTROL PANEL SINGLE LINE DIAGRAM GENERAL NOTES 1 —ALL ITEMS AS SHOWN HEREIN AND /OR SPECIFIED SHALL BE CONSIDERED NEW (UON). 2— LANDLORD SWITCHBOARD IS ASSUMED TO BE EXISTING. 3 —MAIN SWITCHBOARD VOLTAGE SYSTEM AND ARRANGEMENT IS ASSUMED, FIELD VERIFY AND REPORT DISCREPANCIES TO THE PROJECT MANAGER. 4 —SHORT CIRCUIT RATING OF TENANT MAIN PANEL "HA" MUST BE EQUAL OR HIGHER THAN AVAILABLE SHORT CIRCUIT AMPERES. PANEL 'HA' SHALL BE EITHER FULLY RATED OR TO BE SERIES RATED WITH UPSTREAM FEEDER OVERCURRENT PROTECTION DEVICE FOR THE AVAILABLE SHORT CIRCUIT AMPS. ELECTRICAL ENGINEER OF THE RECORD SHALL ADHERE TO THESE REQUIREMENTS. 5— ELECTRICAL DISTRIBUTION EQUIPMENT SHALL BE PRODUCTS OF THE SAME MFR. ACCEPTABLE MFRS. SHALL BE: EATON, G.E., SIEMENS, AND SQ —D. (3) #18 THWN CU (1) #8 CU GRND IN 3/4" CONDUIT CURRENT LIMITTERS PANEL FOR 13 * REFER TO ARCHITECTURAL INTERIOR ELEVATIONS FOR EQUIPMENT LAYOUT. RESPONSIBILITY NOTES 1. ALL CUTTING OF ROOF OPENINGS, SUPPORT FOR ROOF OPENINGS, CURBS, FLASHINGS, REPAIR TO ROOF, ETC., ASSOCIATED WITH THE SHALL BE THE RESPONSIBILITY AND PART OF THE CONTRACT WITH SULB— CONTRACTOR. SULB — CONTRACTOR SHALL EMPLOY THE LL'S WORK SO AS TO MAINTAIN THE ROOF BOND. 2. THE CONDUITS REQUIRED FOR THE MECHANICAL CONTROLS SHALL BE SUPPLIED BY THE ELECTRICAL CONTRACTOR. THE ELECTRICAL WIRING FOR THE MECHANICAL CONTROLS SHALL BE, PROVIDED BY THE MECHANICAL. CONTRACTOR. PITCH PANS, ROOF HVAC SULB — CONTRACTOR THE HVAC ROOFERS FOR THIS 3. SANITARY SEWER AND DOMESTIC WATER SHALL BE STUBBED INTO OR NEAR THE THE PREMISES BY THE LNDLORD. SEE MECHANICAL SHEETS FOR LOCATION OF STU LB —INS. 4. THE SPRINKLER CONTRACTOR SHALL SUBMIT SHOP DRAWINGS TO THE TENANT'S LNDLORD AND TO THE APPROPRIATE RATING BUREAU FOR THEIR APPROVAL. A COPY OF THE APPROVAL LETTER FROM THE RATING BUREAU SHALL BE FORWARDED TO THE TENANT'S LNDLORD. MUST USE THE LNDLORDS DESIGNATED CONTRACTOR. 5. THE TENANTS GENERAL CONTRACTOR SHALL RUN ALL CONDUIT FOR ELECTRICAL FLOOR OUTLETS, TELEPHONE OUTLETS, AND LINES REQUIRED FOR PLUMBING ROUGH —IN TIGHT AGAINST THE UNDERSIDE OF THE FLOOR SLB. THE FLOOR STRUCTURAL SLB SHALL BE CORED AS REQUIRED TO INSTALL THESE ITEMS AT THE LOCATIONS SHOWN ON THE PLNS. 6. THE HVAC SUB — CONTRACTOR SHALL IDENTIFY ALL ROOF MOUNTED HVAC EQUIPMENT AND APPARATUS WITH 6" HIGH PAINTED STENCILED STORE NAME ON ALL SIDES OF EQUIPMENT. 7. THE LL'S DESIGNATED CONTRACTOR SHALL MODIFY EXISTING SPRINKLER LOCATIONS AND ADD ADDITIONAL HEAD WHERE REQUIRED TO CONFORM WITH NEW FLOOR PLAN AND CEILING DESIGN LAYOUT AS REQUIRED BY LOCAL CODES. -ELV--n(p REVIEWED FOR COMPLIANCE WITH NFPA70 - NEC MAY 3 1 2011 City of •Tukwila BUILDING DIVISION RECEI CITYOF TU VI LA MAY 232011 PERMIT CENTER TD1102_E11 Linane /Drews Architects 3500 West Burbank Blvd Second Floor Burbank, CA 91505 818.972.5080 818.848.3895 Fax All information shown or described herein is the property of Linane / Drews Architects, Incorporated; and shall not be reused, copied, or reproduced in any form without the express written authorization of Linane / Drews Architects, Incorporated. Q Copyright: Linane/Drews Architects, Incorporated 2011 All rights reserved. dp DON PENN CONSULTING ENGINEER 835 WESTPORT PARKWAY, SUITE 300 GRAPEVINE TEXAS 78051 817 - 410- 28l�i8 FAX 817 - 251 -8411 ISSUED FOR: DATE PRE BID /BLDG. DEPT. SUBMITTAL 03.25.11 BID /LL FINAL REVIEW 04.08.11 CONSTRUCTION SET 05.17.11 No. REVISION ISSUES: DATE WESTFIELD SOUTHCENTER SPACE # 592 536 SOUTHCENTER MALL TUKWILA, WA 98188 STORE NUMBER: 357 Drawn By DM A/E Job Number TD1102.00 Checked By KG Fie Name T01102 _E11 Project Mgr. DM Scale: Title: PANEL SCHEDULES Sheet No. E1.1 PLOT DATE 5.18.2011 LB- 13,15,2,12 O • ane /Drew s it Architects ects Loin�� a » v 3500 West Burbank Blvd Burbank CA 91505 arc Second Floor 818.972.5080 40' 0" L co I - - ................ ............_.........._._.... ................ .........._... ....__.__.. ............... ................ ............... .._....._.._... J a o o _. _....__ ..... O ............. ..._._........ ............... .._............. 1 818.848.3895 Fax All information shown or described herein is the property of Linane / Drews Architects, Incorporated; and shall not be reused, copied, or reproduced in any form without the express written authorization of Linane / Drews Architects, Incorporated. © Copyright: Linane /Drews Architects, Incorporated 2011 All rights reserved. © 4' -0„ , AZ., rn '.c '1 r 1 �© `). `ly`S X -RAY FLOOR PRIOR TO ANY SAW CUTTING OR CORE DRILLING \\\ '\\\ \\ . .0. \ \\ 4 10n..._ -rs•C°1 dp DON PENN CONSULTING ENGINEER 895 WESTPORT PARKWAY, SUITE 900 GRAPEVINE TEXAS 78051 817-4104 FAX 8174514411 r__ __ � I TYP. \\ — t..... \\ ... I - - ----1 • 0 0 o 0 0 GENERAL NOTES I. CONDUITS SHOWN OFFSET FOR DRAWINGS CLARITY. CASH WRAP KEYNOTES O FIXED IN -PLACE CASH -WRAP FURNITURE FIXTURE. CONDUITS SHALL BE ROUTED FROM FRONT FURNITURE CONCEALED IN FLOOR ©SHALL BE CUT AND PATCHED IN A NEAT MANNER AND PER MALL REQUIREMENTS.CONTRACTOR JUNCTION BOX IN THE TRENCH UNDER FURNITURE ACCESS PANEL FOR EXTENSION CONDUIT WHIPS PROVIDED BY THE FURNITURE MFR. PROVIDE SURFACE MOUNTED SERVICE FLOOR BOX FOR POWER AND DATA, O 665 -SC WITH SOLID ALUMINUM COVER WITH RECESS FLOOR COVERING, THOMAS PROVIDE (3) DEVICE PLATES WITH 1 1/4" DIA. HOLE, T &B CAT 665 -STEL. FIT UNDER FIXTURE. O DOUBLE DUPLEX DEDICATED GROUND RECEPTACLES. OUTLET FURNISHED CONTRACTOR TO MAKE FINAL CONNECTION OF POWER WHIP TO JUNCTION <> SIMILAR TO NOTE #4 EXCEPT DUPLEX DEDICATED GROUND RECEPTACLE. O6 FIXTURE MANUFACTURER TO PROVIDE FLEX CONDUIT AND CONDUCTORS AS GROUND AND GROUND WIRES. ROUTE CONDUIT IN FURNITURE BASE AND . (2) 2 "CONDUIT WITH PULLSTRING TO CABLE TRAY ABOVE, CONDUITS SHALL BENDS. 0 , / ea 0 0 GANG MUD RING FOR DATA PORTS. EXTEND 1 , /2" CONDUIT WITH PULLSTRING ROUTE CONDUIT IN FURNITURE TO LINK ZONE 5 ON 5 BUTTON if 144 . SLAB AND OF STAMPED STEEL, &BETTS FLOOR BOX AND INSTALLED BOX IN FIXTURE SHOWN. WIRING SUPPORT ON HAVE A MAXIMUM 5 IN ONE TRENCH. FLOOR TO PROVIDE WIRES TO THE OUTLETS THOMAS & BETTS CAT 665 - CST- SWR -ALM TO BE RECESSED ENOUGH BY FIXTURE MANUFACTURER. BASE. TO INCLUDE DEDICATED THE FURNITURE WALL. OF 270 DEGREES 4 FLOOR AND CAT TO IN O 5 O 2 GANG JUNCTION DATA JACKS g TELEPHONE OUTLET O TO A/V RACK 10 1" CONDUIT WITH BASE AND SUPPORT 11 PROVIDE OVERRIDE OVERRIDE SWITCH . a O BOX BY AND FACEPLATE WITH (3) AT B.O.H. VIA PULLSTRING ON THE SWITCH IN THE CORRIDOR. _ __ _ __J 5 FIXTURE MANUFACTURER WITH SINGLE BY OWNER. JACKS IN SINGLE GANG JUNCTION BOX, CABLE TRAY. FOR DATA CABLES BY FIXTURE MANUFACTURE. FURNITURE WALL. OVER THE J -BOX AND USE J -BOX CONDUIT ISSUED FOR: DATE PRE BID /BLDG. DEPT. SUBMITTAL 03.25.11 BID /LL FINAL REVIEW 04.08.11 CONSTRUCTION SET 05.17.11 No REVISION ISSUES: DATE A A A A /\ / \ / \ A _ _ - �, Tom' Y. ti \ +'TORE �..,,. '`-- -_ CASHWRAP DETAIL SCALE: NONE it f L N -... POWER: BLACK OUTLET & ^, , .:: -i. ' COVER, WHERE OCCURS, SEE ,0 ^ - f ,°a ,, SHEET Z E3.0 R EVIEWED:FOR MAY 3 1 2011 DSW008/ DSWO13 ' 2'-0 " DSW004 - �` DSW005/ DSW006 , o I ,- a� _ a co City atTukwila BUILDING DIVISION WESTFIELD SOUTHCENTER SPACE #592 536 SOUTHCENTER MALL TUKWILA, WA 98188 FEEDER CONDUIT PHASE °`--d ISOLATED GROUNDING CONDUCTOR PANELBOARD FEEDER CONDUCTORS MAIN BREAKER �� �� - i ) — EQUIPMENT GROUNDING CONDUCTOR NEUTRAL CONDUCTOR HOT BUS BAR BRANCH STORE NUMBER: 357 BREAKER GROUNDING TYPE �., C� • -- PANELBOARD .. 1 • Drawn By DM A/E Job Number TD1102.00 � EQ c- EQ - li Checked By KG File Name SD OA OB OC "NEUTRAL" Project Mgr. DM Scale: , BUS BAR EQ EQ EQUIPMENT GROUND BUS BAR, BONDED TO ENCLOSURE Title: ELECTRICAL DETAILS y LOCK NUT TYPICAL ISOLATED GROUND BRANCH CIRCUITS. 3/4" C. 1 ii, • INSULATED ISOLATED GR GITY�FTI KWILA BUS BAR WITH (4) #12 & (1) #10 GRD. TO OUTLET BRANCH CIRCUIT ® MAY .2 2011 CONDUIT ll o_ I� 1�' PHONE DATA: BLACK OUTLET COVER, BOOR, RE: SHEET I�.", ERMIT CENTER GREEN INSULATED NOEEGREEN CENTERLINE 1 & WHERE OCCURS, SEE SHEET E3.0 & F1.0 GROUNDING GROUNDING WIRE CONDUCTOR (INCLUDING BUS BAR) SHALL ONLY BE ELECTRICALLY POWER: BLACK OUTLET & COVER, WHERE OCCURS, SEE SHEET E3.0 & F1.0 OF FIXTURE PANEL CONNECTED TO GROUND AT THE TRANSFORMER NEUTRAL - GROUND BONDING POINT. Sheet No. E 1 • 2 POWER & PHONE AT BASE OF FIXTURES SCALE: DEDICATED GROUND WIRING DIAGRAM 3� SCALE: 2 NONE NONE TD1102_E12 PLOT DATE: 5.18.2011 TD1102_E13 PLOT DATE 5.18.2011 REFER TO PLANS FOR NUMBER BACK OF HOUSE —� Linane /Drews A r c h i t e c t s OF PROJECTORS. SPEAKERS & MAIN AV RACK RCK101 I I SUBWOOFERS I I r SMALL PROJECTOR (3) CAT 5 I I LOW VOLTAGE DATA /DMX CAT.5E WIRES PROVIDED AND INSTALLED BY OWNER (LION). CONDUIT AND CABLE TRAY ROUGH -INS BY G.C. SEE PLANS FOR DETAILS. CABLE TRAY - PROVIDED BY ELECTRICAL CONTRACTOR I I . •• - - - •- - - -- �•t SMALL PROJECTOR I if.,,Ii a (J) (n ii, :ill � ''~V o v 3500 West Burbank Blvd �/ Second Floor Burbank, CA 91505 818.972.5080 '1=1 I PROJECTOR MANAGER'S DESK " ABOVE MANAGER'S DESK 3 CONDUIT J 2 CATS O I 3/4" CONDUIT BELOW MANAGER'S DESK I r r r LARGE PROJECTOR _� LARGE PROJECTOR LIGHTING FIXTURE SCHEDULE —� J 818.848.3895 Fax LARGE PROJECTOR —� All information shown or described herein Is the property of Linane / Draws Architects, Incorporated; and shall not be reused, copied, or reproduced In any Linane /Drews Architectsslncorporut authorization of c Q Copyright: Linane /Drews Architects, Incorporated 2011 All rights reserved. LARGE PROJECTOR I J (4) CAT5 I ` J 1 -1 /4" CONDUIT MAIN CASHWRAP. H=1 TYPE WATTS LAMP DESCRIPTION MANUFACTURER CATALOG NO FINISH MOUNTING/ LOCATION SYMBOL NOTES PROJECTOR R J NO. TYPE LARGE PROJECTOR (7) CAT5 J (2) CATSE 3/4" CONDUIT J �) —❑ SPEAKERS AA01 27 2 LED RECESSED 2 HEAD ADJUSTABLE ACCENT - LED AMERLUX #DCRNTR22R -2 -20- LED - E -BT- 120- NF -BF -BT -3000- SN3 /4 BLACK TEXTURED RECESSED/ STORE SOFFIT AA01 lA01 CENTERED BETWEEN STOREFRONT FLASS AND EDGE OF SOFFIT SON 3� cy $Cs o a, ¢ ; _o; -' C t �^ "_ o I-' "1 w y d A p4'MCL •w.., �' , - " P `S �0� , ■ - I ..00' o 4 , CAT5P 1" CONDUIT J TELEPHONE BACKBOARD (8) CAT5 CONDUIT SP1 SP1 SP1 SP1 SP1 SP1 SW SW (1) 14AWG TP J J J J J STOCKROOM PHONE (1) CAT5 a 1/2 CONDUIT J TRAXON COLOR WASH. 1 AA01 -EM 1 SAME AS AAO1 EXCEPT POWERED THROUGH INVERTER J J CC01 6 12 RGB LED COVE LIGHT 12 SMD 1 PXL RGB DMX ( ) TRAXON FIXTURE: MB -CL- 5010100 POWER /INJECTOR CABLE: TI PI 0000100 LED SMART ENGINE 100W: PS IA 0010000 TX CONNECTOR INJECTOR TI ZI 00001 TX SMART EXTENSION 5M TI EC 500000 PERIMETER COVE LIGHTING/ SALES AREA Co NO ACCESSORIES NEEDED (NO MOUNTING CHANNEL NEEDED) J -1/2 HOLE IN TOP OF (1) CAT5 (TYP OF 6) THEATRE POST: BY G.C. � I-C) I-® C HO dp DON PENN CONSULTING ENGINEER 636 WESTPORT PARKWAY, SUITE 300 GRAPEVINE TEXAS 76061 817 -410 -2868 FAX 817-251-8411 MAGIC MIRROR _�, (3 CAT 5 J (3) SP2 SP2 — -1 ri SP2 — SP2 — I — — — UP NEXT (7.1116 r� (p BOYS HERO I I H 1 CCO4 40 36 RGB LED TRAXON WASH RGP 350MA TRAXON FIXTURE: XB WE 211X1 LED ENGINE TRACKMOUNT 350MA 1W: Px IC 5oso2oo SUSPENDED ABOVE THEATRE/ SALES AREA 0004 VIDEO STORE I (3) 2" CONDUITS DST AV RACK RCK102 I I JUKE BOX I(14) CAT5 FRONT SIGN —� I OHANDELIE 60 8 DECORATIVE CHANDELIER 0W8 - OLDE WORLD CHROME ACCENTED CRYSTAL CHANDELIER, 8 LIGHT BETWEEN PRINCESS HERO AND MAGIC MIRROR ° ° °y ; ° ° ° CHANDELIER LDISNEY STORE THEATRE _I ATV ROOM LIGHTING CONTROL/AUDIO VISUAL SCHEMATIC DIAGRAM 1 FX02 150 1 CDM 150/T 6.946 PROJECTOR:36 DEG. BEAM HID PATTERN PROJECTOR WITH G080 ROTATOR GLASS HOLDER, SAFETY CABLE COLOR FRAME 6.25" CITY THEATRICAL SHORT S4 TOP HAT, DOUBLE GO80 ROTATOR, STAINLESS STEEL GOBO- NEBULA. ETC /GAM: 436HID -A WITH PARALLEL BLADE CONNECTOR -436LT ETC SOURCE 4: PATTERN HOLDER: 400PH -6 SAFETY CABLE: 400SC COLOR FRAME: 400CF CITY THEATRICAL: S4 TOP HAT: 2440 GAMONUNE: DOUBLE GOBO ROTATOR: TS5574 GOBO LIGHT PROVIDED BY OWNER- Ro696 GOBOS, ROTATiON 77896 NEBULA - GLASS HOLDER BLACK SUSPENDED/ STOREFRONT ENTRANCE FXOZ ° ISSUED FOR: DATE Cable Notes: / IOTA IIS -375 -I Notes: TouchScreen logic 4 and 4A. 2 Momentary wiring) drop length off the switch network. Make Module (EIM). The from the lighting LAN security. be powered with Relays should be wired one -line. Refer to plans Information. main EIM can to for PRE BID BLDG. DEPT. SUBMITTAL 03.25.11 BID /LL FINAL REVIEW 04.08.11 1.) 32 Momentary switch terminations are provided with each ControlKeeper board. 4 Momentary switch terminations are provided with each ControlKeeper switch terminations are provided with each ControlKeeper 2. (use 18/3 for LV 2.) The Digita switch network length cannot exceed 1000 feet. The maximum BUS cannot exceed 29.5 feet. 1 Di Digita Gateway ma be placed on an Di Digita 9 Y may P any 9 4.) The Building IT personnel are required for setup of the Ethernet Interface be located anywhere on the lighting control network. The EIM provides a connection control network to the building LAN. A VPN connection is available for added 5.) The ControlKeepers with Emergency Power Interrupt Relays (RIM) should emergency power as well as normal power. The Emergency Power Interrupt normal power. 6.) This one -line drawing is for concept only. Do not wire the system per this location, size, and quantity. Refer to the Installation Instructions for correct wiring 7.) Cooper Controls provides a 3 year warranty on all logic boards. 8.) Cooper Controls provides a 10 year warranty on all relay cards. RS-485 Network Feed inverter and relay 47 ® Belden #9841 or CAT 5 recommended. By G.C. with primary unswitched wills source. Relay 31 will switch c RS -232 Cable (6 Feet) sense connection with Provided by Cooper Controls inverE1tf5 nder 9 a Use LCCNP Non-plenum cable or Belden 1502R cable. normal power conditims. P For more information, please see Digita whin details in p 9 9 this submittaLB G.C. Primor�unswitched By — CONSTRUCTION SET 05.17.11 / Inverter To Emergency li lighting fixtures 9 y 9 9 vi °t (t zov) F1 /// 1 LED / 5W WALL RECESSED EDGELIT EXT - SGLE EXITRONIX GREEN RECESSED WALL SALES AREA F1 RECESSED WALL SINGLE FACE output Leads / Flying Lead Orange (277) not used Black (120) ControlKeeper T 32 size enclosure Panel type: NEMA 1 Panel size: 41 "Hxl 5 "Wx6.25 "D F1D 5 1 LED 5W / WALL RECESSED EDGELIT EXIT - DOUBLE FACE, GREEN LETTERS, WHITE HOUSING EXITRONIX V903- WR- WB -GC -WH GREEN LETTERS RECESSED WALL MOUNTED / SALES AREA F1 D 'As RECESSED WALL MOUNTED - DOUBLE FACE , Oran e 277 not used 9 ( ) 0 LAN Cable Black (120) Use certified CAT 5 cable for TCP /IP communications Low Voltage Switch Wire ® Neutral 1813 AWG. By G.C. • Lin I \ No. REVISION ISSUES: DATE ^ / \ F2 3 1 LED / 3W UNIVERSAL THERMOPLASTIC EXIT SIGN - GREEN LETTERS, WHITE HOUSING ASTRALITE TP- U- G -W -EM GREEN LETTERS UNIVERSAL/ BACK OF HOUSE F2 F3 5.4(x2) 2 5.4 TUNGSTEN LAMPS BUG EYE WHITE EXITRONIX LL90 WHITE WALL MOUNTED/ BACK OF HOUSE �� RECESSED WALL MOUNTED - SINGLE FACE A � � osw- u- 0721-MV= of 3 Line Wall Mount Motion Smear � F4 60 2 SYL F32T8 3500K GENERAL PURPOSE WRAPAROUND CRESCENT DLT232BL2Y CEILING/ BACK OF HOUSE S - i- liu,; ° is °^eR i / \1 o " '! a':I �"t�«.^sIr'/ a ; ; a; F4 ■"7', 'ryy�, aw:�I =� ^% ® To Light Fixtures Y.II I IFS ^: I '.'I I I � gum,/ jG / F4A 60 2 SYL F32T8 3500K GENERAL PURPOSE WRAPAROUND W/ EMERGENCY - CRESCENT DLT232BL2Y —B0, 600 -700 LUMENS CEILING BACK CEILING/ OF HOUSE > ai m � � from VFW': t ai i Od 1 e n� , ,n ,w„ r° -" °°"^" ^� r �+ .,a., ^- Power ti .. •^r r Breakers to °„"S�„^c„r' Relays in LCP. £'S,;,,"FkP'/ a„n m Power LCP../ '� - `� _ L "' I 1 � i .I;' _i Illy 11 " reat r. . ^ ^A'"r Tr cKeeumi0n 2 r,r � ,° ' ^ / \ m" "^ "" .•. " -.�. P'S„ g °-^ `., -'- ,• -^�P'/ ,,,,, ,� ^ Panel r. r eoo F4A '° al R. �,,,/ , r.... MP -w. ® r /AAA / \ ./ • Load Ceder by others Q LCCNP transformer �"`" with Normal : ; ^ P'% r �p '�'. 1 . �� oil/' : - ■ -ar, •r- am .T."„., m^ P'i rpm Lcr .e„ re rte. -. r� `� vn -ar F5 60 2 SYL F32T8 3500K STRIPLITE SIMKAR CH232811UNV SUSPENDED/ BACK OF HOUSE PROVIDE WIREGUARDS SIMKAR WG240 -48" FOR 2 LAMP CH Power. k"S "EkP/ / -. : d� I' [le, i' r_ �'S� -^�P'/ icn �.e,� m ^/ -.. `rn "a u� +a °� s..m , <r•r m . w. - bw� c / A mi. 1 1 F5 coa�raterp�mWded by others EIM Ethernet Interface Module (EIM) - 12 n -m, derw a- wr«a- rw"oi"' COOPER Controls 203 Cooper Circle Tel: +1 -800- 553 -3879 Peachtree City, Fax: +1- 800 -954 -7016 GA 30269. USA Email: controls @cooperindustlies.com Example of Track fixture control wiring \ F5A 60 2 SYL F32T8 3500K STRIPLITE W/ EMERGENCY SIMKAR CH232B11UNV EM SUSPENDED/ BACK OF HOUSE PROVIDE WIREGUARDS SIMKAR WG240 -48" FOR 2 LAMP CH a Digits Gateway Typical of 1 1 F5A ��: %r t t. _ , "T �..� — — Digita5 -1B Dgita5 -5B switch located Behind stage go F6 8 1 T5 UNDER CABINET LYTE LITHONIA UC12E UNDER CABINET/ MANAGER'S DESK FB I 1 at register ovenideswitcn ----2 2 wire low voltage, 24vdc /common from LCP COOPER CONTROLS ONE LINE DIAGRAM SCALE 2 TK - - - 1 CIRCUIT / 120V TEK SERIES LINE VOLTAGE TK2 - 2' 11<4 T4 - 4' TK8 - 8' ELITE: ET2BK ET4BK ETBBK LIVE ENDS: ELITE/NORA ET1018K STRAIGHT CONNECTORS: ELITE /NORA ET107BK BLACK SUSPENDED/ SALES AREA TK N.T.S. Digita switch Bus Digita Switch Input: Controls Up to 64 software programmable digital inputs are standard on the ControlKeeper lighting control panels. Each input can be programmed to control any relay or group of relays in the system. ControlKeeper TouchScreen lighting control panel ,140° mmi...rrr TNF 13.5 4 LED CLUSTERS VERTICAL LED TRACK HEAD WITH VERTICAL BALLAST AND NARROW FLOOD OPTIC . AMERLUX DCRNTV-22-20- LED -E -BT- TN 1- 120 -NF- 3000 - SN3 /4" BLACK SALES AREA TNF m TFL 13.5 4 LED CLUSTERS HORIZONTAL LED TRACK WITH HORIZONTAL BALLAST AND FLOOD OPTIC AMERLUX DCRNTH- 22 -20- LED -E -BT- TN1- 120 -NF- 3000 - SN3 /4" BLACK SALES AREA Tit ti WESTFIELD SOUTHCENTER SPACE # 592 536 SOUTHCENTER MALL TUKWILA, WA 98188 TFL -EM 13.5 4 LED CLUSTERS HORIZONTAL LED TRACK WITH HORIZONTAL BALLAST AND FLOOD OPTIC W/ LOCKING MECHANISM AMERLUX DCRNTHLOCK- 22 -20- LED -E -CT- 120 -FL -3000 - SN3 /4" -DIM BLACK SALES AREA TFL-EM am r �'r " � 14� �) .r „ °.. Digita Gateway front view TB2 Terminal Block Connection: Green wire GreenNVhite to GND wire to 1 A I- a-- - -- -- — '. +24VDC REVIEWED FOR �+ COMPLIANCE WITH ;;,.;;/ 9 LED CLUSTERS VERTICAL LED TRACK HEAD WITH HIGH WATTAGE AMERLUX DCNTRV- 33 -24- LED -E -BT- TN1- 120 -NF- 3000 -SN1" - GELS TBD BLACK SALES AREA HERO FIXTURES TIiw COLORED GELS TBD o �, ” NFPA70 NEC 4111 MAY 4111 STORE NUMBER: 357 TLV_ - - - 12V LOW VOLTAGE LIGHTING TRACK - TRAC 12 TL SERIES 6' -0" LENGTH JUNO TL6 -WH TRANSFORMERS: JUNG TL550N -BL CONDUIT FEEDS: JUNO TL34WH END FEEDS: JUNO TL38WH WHITE THEATRE TRUSSES/ DISNEY STORE THEATRE TLV_•lyt 11 o L Gateway Drawn B By A/E J Number TD1E Job o r rearvIe rearview City otTukwila �7 DIVISION BU ILDIN.. Checked By KG File Name TD1102.�13 J - IC T,- -.r e r TerminationDevbe 1 Project Mgr. DM Scale: TLV 37 - SYL #58641 NFL24/ 0 (COVERED (COVERED HID LAMP) LOW VOLTAGE MR16 TRACK HEAD JUNO TL190WH WHITE THEATRE TRUSSES/ DISNEY STORE THEATRE Title: ELECTRICAL DETAILS e Digita Switch BUS wiring detail: Black Q' I e 7r Dlgita5/5 Notes: C o DIgtta5/1 _ - VDC Ground _ Dermi anon sus Blue - CAN L (Terminated at both ends) gp Termination Daubs Red - +24VDC White - CAN _H (Terminated at both ends) CITY 'V(. A MAY ,2 S 2011 Digita Switch Bus information: rap Digita Switch Bus length can not exceed ',KERMIT CENTER SEE ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT LOCATION AND MOUNTING HEIGHT OF ALL LIGHTING FIXTURES. 1.) Digita buttons are factory engraved panel. The maximum drop length off the Digita Switch 2.) Each Digita button can be programmed to control any relay or group of Bus can not exceed 19 feet. No more than 60 switch relays on the network stations and 1 Digita Gateway can be powered from a 3.) Digita buttons can be address identically on the network to allow for easier ControlKeeper lighting control panel. Make certain that programming of a three way switching senario. the ends of the Digita Switch Bus is properlay terminated. 4.) LED status is available for each 5.) White Decora style wall plate included with Digita switch. Refer to the Digita Switch installation instructions for Custom color and configurations are available for wall plates. complete installation information. Sheet No E1. .3 LIGHTING FIXTURE SCHEDULE �5 NOT USED SCALE �4 SCALE N.T.S. DIGITA SWITCH WIRING �3 TD1102_E13 PLOT DATE 5.18.2011 G.C. TO PROVIDE (2) 3/4" CONDUIT TO A/V RACK. 29 LA -19 E3 LA -19 t- ._... -4 CCO1 <- LA -19 TEL TNF LA -22 TK8 THW TK8 K8 I'N• TEL 'T NE TNF TEL TNF TNF- TEL TNFTNF TEL TNF TEL TNF TNF TEL TNF TNF .11.1. l ON INVER!WEM 1FL-EM —4 1NF 'HO TNF TNF,�F TNF • TKF, 1<8 EL TNF TNF TEL TNF TNF f ('ROJO2 TNF TNF TNF: CH.PNDE.I_IEf O 0 0 .......\TNa. .-9 coo T.K8 Tr:�1 TI TFL TNF 'TNF TEL TNF TNF TEL TNF TNFTFL TNF NF TNF ' NFF AROI TNF TNF LA -31 LA -30 TNF .INFO TNF TNF TNF LA -19 LA -19 LA -21 \ 74, ON INVERTED •TN F TNF. ITiiF. .TNF. AA( TNF LA -30 LA -19 LA -19 LA -21 ON INVERTER 5 c ^: !' ° TNF TNF TNF TNF TNF TNF _ � I \ .. ,O� (TYPICAL) ) , � ` TP; F 1 � ran �� WY IN : o \ O LA -21 ' LA -10 \ p�ON INVERTER t 2 1K 4 E: M LA -16 .. 2 TNF TI-I W TNF TNF TNF TNF AA {)1 F3 .I F5 u 1 Fci TNF TEL INF TNF TFL TNF TGIF TEL TNF TNF TEL TNF TNF TFL TNFTM:TEL 'I NF T<; ; TK8 TNF1 TNr TNF X02 TNF TNF, 1Y: TNF LA -19 TNF. TNF i TNF 1NF LA -2 TNF, TNF TNF TNf: ?NF TEL TNF' Ti',F TFL. T TNF TFTL. TNF TNF TEL TNI" TNF TI-NTNF TEL TNF TFL INFTNi TEL INF- TNF' IF TNF: TNF TEL iNF - -FLTNFTNF TK8 Tk8 THw iK2. LA -17 TNF BjY L TNHtFrFI..TNF LA -15 AA(:. AAO1 AAO1 C''O1 (......_ ..............................................._............................. ..............................> CCO }Colt CCOi UA\ LIGHTING PLAN r OUTLETS LOCATED AT 9' -0" A.F.F. IN STOCK/SALES AREA WALL AND SHALL BE SPACED AT 15-0" LINEAL FEET (MAX) ALONG LIGHT GOVE AND POWER ONLY (15) LIGHT FIXTURES. 120 VAG 1 IOOw / 24v PSU 1 1 120 VAG •Q I 0 HARDWIRED CONNECTION 120 VAG 100+4 / 24v PSU 0 IO0w / 24v PSU 1 1 120 VAG f 0 DMX DA 4 SPLITTER LOCATED IN AN RAGS t' SIN HA -GT o7- FInOSE DM L DMX SPLITTER 120 VAG OUTLETS LOCATED AT 9' -0" A.F.F. IN STOCK/SALES AREA WALL AND SHALL BE SPACED AT I5-0" LINEAL FEET (MAX) ALONG LIGHT COVE AND POWER ONLY (15) LIGHT FIXTURES. IOOw / 24v P5U o SALES AREA OUPLER (IN LIGHT COVE) OWER INJECTOR GABLE COVE LIGHT GOVE LIGHT OWER INJECTOR GABLE COVE LIGHT GOVE LIGHT COVE LIGHT GOVE LIGH COVE LIGHT COVE LIGHT I COVE LI1 T rCOVE LIGHT COVE LIGHT GOVE LIGHT COVE LIGHT DOVE LIGHT TO ADDITIONAL SEGMENTS OF 5 FIXTURES MAXIMUM NUMBER OF FIXTURE PER DMX512 UNIVERSE 15 110 DOVE LIGHT (LAST FIXTURE LIGHT COVE 1) COVE LIGHT GOVE LIGHT COVE LIGHT COVE LIGHT COVE LIGHT COVE LIGHT COVE LIGHT GO LIGHT COVE LIGHT COVE LIGHT COVE LIGHT COVE LIGHT DOVE LIGHT COVE LIGHT COVE LIGHT POWER INJEGTOR GABLE COVE LIGHT r GOVE LIGHT 1 DOVE LIGHT COVE LIGHT COVE DOVE LIGHT 3 PIN XLR -RJ45 ADAPTOR 120 VAG f I•° 1 0 1 I0Ow / 24v PSU 120 VAG 0 O a 100w / 24v P51) GOVE LIGHT GOVE LIGHT (1ST FIXTURE LIGHT COVE 2 CIRCUIT) NTERGONNEGT GABLE — INJEGTOR BOX (114 LIGHT COVE) LIGHT COVE I GAT5/DMX COVE LIGHT COVE LIGHT \COVE LIGHT GOVE LIGHT COVE LIGHT l sir 1_€�I ra, rar ti>� COVE LIGHT COVE LIGHT DOVE LIGHT COVE LIGHT COVE LIGHT Jar __I Ln l.x, • tai 1 1 GOVE LIGHT COVE LIGHT COVE LIGHT GOVE LIGHT COVE LIGHT COVE LIGHT COVE LIGHT COVE LIGHT COVE LIGHT COVE LIGHT COVE LIGHT COVE LIGHT GENERAL CONTRACTOR TO PROVIDE (2) 5/4" CONDUIT FROM CLOSEST SALES WALL LOCATION TO AN RACK. THIS LOCATION DETERMINES THE SPLIT OF THE LIGHT COVE INTO TWO SEPARATE BUT IDENTIGAL CHAINS. LIGHT COVE 2 INJECTOR BOX (IN LIGHT COVE WALL) 1 INTERCONNECT GABLE COVE LIGHT COVE LIGHT COVE LIGHT COVE LIGHT (1ST FIXTURE LIGHT COVE 2 CIRCUIT) 1 1 120 VAG 1 1 0 HARDWIRED CONNEGTI 0 IOOw / 24v PSU 120 VAG qy 100w / 24v 1 J L J COVE LIGHT COVE LIGHT DOVE LIGHT COVE LIGHT OVE LIG T COVE LIGHT COVE LIGHT COVE LIGHT DOVE LIGHT COVE LIGHT COVE LIGHT POWERI1 L _J 1 COVE LIGHT COVE LIGHT GOVE LIGHT GOVE LIGHT COVE LIGHT .DOVE LIGHT DOVE LIGHT DOVE LIGHT COVE LIGHT COVE LIGHT COVE LIGHT COVE LIGHT DOVE LIGHT INJECTOR GABLE // - COVE LIGHT COVE LIGHT COVE LIGHT COVE LIGHT COVE LIGHT COVE LIGHT COVE LIGHT GOVE LIGHT COVE LIGHT COVE LIGHT COVE LIGHT DOVE LIGHT COVE LIGHT COVE LIGHT COVE LIGHT POWER INJECTOR GABLE TO ADDITIONAL SEGMENTS OF 15 FIXTU GOVE LIGHT DOVE LIGHT COVE LIGHT COVE LIGHT GOVE LIGHT OWER INJECTOR GABLE 1 COVE LIGHT COVE LIGHT COVE LIGHT COVE LIGHT COVE LIGHT COVE LIGHT COVE LIGHT DOVE LIGHT COVE LIGHT COVE LIGHT COVE LIGHT DOVE LIGHT (LAST FIXTURE LIGHT COVE 2) LI&HT COVE WIRING DIA&RAM MAXIMUM NUMBER OF FIXTURE PER DMX512 UNIVERSE 15 110 NOTES: I /4 "=1' -0" L I SHT I NO NOTES 1. ALL LIGHT FIXTURES WILL BE FURNISHED COMPLETE WITH LAMPS, BY THE TENANT AND SHALL EE INSTALLED AND CONNECTED BY THE ELEGTRIGAL CONTRACTOR. 2. 3. 4. 5. b. NOT USED. COORDINATE LOGATION OF ALL FIXTURES WITH ARCHITECT'S REFLECTED GEILING PLAN. NO EXPOSED CONDUIT ALLOYED. G.G. 15 RESPONSIBLE FOR PROVIDING THE SWITGHGEAR, WHERE APPLICABLE. G.G. TO PROVIDE ALL MOUNTNG HARDWARE FOR TECH LIGHTING. SHEET NOTES OALL HOMERUNS ON TH5 5HEET ARE TO PANEL "LA" AND NEW, UNLESS OTHERWISE NOTED. 4s 4t• LIGHTING GONTAGTOR REFER TO SHEET ELI FOR FURTHER DETAILS. BY -PASS TIMER (0 -2 OURS). PROVIDE NAMEPLATE "LIGHTING OVERRIDE TIMER ". VERIFY EXACT LOGATION. SEE ARGHITEGTURAL DRAWINGS FOR MOUNTING HEIGHT AND LOCATION OF CHANDELIER REFER TO SHEET E2.I FOR '0004' ROUTING. 20 AMP DEDICATED 61RCUIT YV/ NEMA 5-15 OUTLET MOUNTED AT IS' AFF INSIDE AV ROOM FOR 0004 LIGHT FIXTURE POWER SUPPLY/ CONTROL PANEL. LOW VOLTAGE TRACK LIGHTING TO BE MOUNTED INSIDE BEAM. SEE FIXTURE SCHEDULE FOR INFO. TRACK END FEED GOIIHlEGTOR, A PART OF TRACK SYSTEM TO BE ORDERED WITH TRACK. MG GABLE FOR CONNEGTION TO LOW VOLTAGE TRACK. ROUTE MG GABLE IN CHANNEL ALONG BEAM. (2) #12 MG GABLES FOR FEEDING LOW VOLTAGE TRACK. PROVIDE (I) GABLE PER TRACK END FEED. ROUTE MG GABLES IN GHANNEL IN BEAM. I I REMOTE LON VOLTAGE MAGNETIC TRANSFORMERS FOR TRACK LIGHTS. MOUNT IN VENTILATED ACCESSIBLE AREA OH NON - COMBUSTIBLE MATERIAL. REVIEWED FOR COMPLIANCE WITH NFPA70 - NEC MAY g 2011 —"dry oT'I ukwila BUILDING DIVISION RECEIVED_ CiTY OF TUKKW�IIA MAY .'2 Id 2011 PERMIT CENTER TD1102_E20 Linane /Drews Architects 3500 West Burbank Blvd Second Floor Burbank, CA 91505 818.9725080 818.848.3895 Fax All information shown or described herein Is the property of Linane / Drews Architects, Incorporated; and shall not be reused, copied, or reproduced in any form without the express written authorization of Linane / Drews Architects, Incorporated. © Copyright: Llnane/Drews Architects, Incorporated 2011 All rights reserved. dp DON PENN CONSULTING ENGINEER 096 WESTPORT PARKWAY, SUITE 900 GRAPEVINE TEXAS 70061 817 - 410 -2818 FAX 817 - 251 -8411 ISSUED FOR: DATE PRE BID /BLDG. DEPT. SUBMITTAL 03.25.11 BID /LL FINAL REVIEW 04.08.11 CONSTRUCTION SET 05.17.11 No. REVISION ISSUES: DATE A BLDG. DEPT. RESUB. 05.17.11 n A n A A n n A A WESTFIELD SOUTHCENTER SPACE # 592 536 SOUTHCENTER MALL TUKWILA, WA 98188 STORE NUMBER: 357 Drawn By DM A/E Job Number TD1102.00 Checked By KG File Name TD1102 E20 Project Mgr. DM Scale: Title: LIGHTING PLAN Sheet No. E2.0 PLOT DAZE 5.1 82011 PHONE JACK FOR (1) 2" CONDUIT FOR ALL LOW VOLTAGE 1 2" CONDUIT FOR TRAXON TELE SIREN INTRUSION PANEL ........................._..........._............._....................................__.... ...._._.__................ICC01 LA -36 CABLE TRAY ALARM KEYPAD Ir LA -29 LOTYP. FOR SMALL PROJECTORS TYP. FOR SMALL PROJECTORS TYP. FOR LARGE PROJECTORS cco1 CCO1 LA -27 TYP. FOR LARGE PROJECTORS LA -41 LA -40 CM CCO1 i RA 0 fb SYMBOL DESCRIPTION MD MOTION DETECTOR ©D WALL MOUNTED MOTION DETECTOR LOW VOLTASE PLAN 1 /4 " =I' -0" 6 -� ERAL OTES OT ES: S= GURITY \OT ES: 1. FOR CABLE TRAY MOUNTING HT. AND DETAILS SEE ARCHITECTURAL PLANS. 2. CIRCUITS TO BE INDIVIDUAL HOME RUNS TO LIGHTING CONTROL SYSTEM 3. ALL CIRCUITS TO HAVE INDEPENDANT NEUTRALS (NO COMMON NEUTRALS) 4. CONDUITS ARE BE SHOWN OFFSET FOR CLARITY. 5. NO EXPOSED CONDUIT AT DEMISING WALL. 0 3/4 "C BY G.C. WITH SPEAKER WIRES TO CABLE TRAY. SPEAKER WIRES TO A/V RACK BY VENDOR. 0 1/2 "C BY G.C. WITH SPEAKER WIRES ROUTED HIDDEN IN CHANNEL IN BEAM. 0 (2) 2 "C.O. WITH PULLSTRING INTO A/V ROOM. EXTEND CONDUITS TO CABLE TRAY ABOVE. TERMINATE WITH CONDUIT BUSHING. G.C. TO PROVIDE 2" PENETRATION HOLES WITH SLEEVE FOR ACCESS TO THEATER. SEE SHEET A7.1. ("4"). LOW VOLTAGE CABLE IN FOR EXTENSION OF (2) CAT. CONDUIT BACK VT EXTEND 3/4 "CONDUIT TO CABLE TRAY. TO A DIO /VIDEO RACK ® CEILING WASH FIXTURE "CC04 ", PENDANT MOUNTED FIXTURE. SEE SHEET A4.1 FOR MOUNTING DETAIL AND HEIGHT. PROVIDE 4S BOXES FOR FIXTURES TO ALLOW FOR RJ45 COUPLERS. DO NOT CUT CONTROL CABLES ON COLOR WASHES. ® EXTEND 3/4 "C TO CABLE TRAY FOR (2) CAT 5E CABLES FOR EACH "CC04" LIGHT FIXTURE. G.C. TO PROVIDE (1) 2" CONDUIT STUB —OUT WITH PULLSTRING INTO A/V ROOM. 0 20A,120V DUPLEX RECEPTACLE IN 4S BOX FOR PATTERN ROTATOR. MOUNT ON UNSTRUT SUPPORT STRUCTURE. VERIFY LOCATION PRIOR ROUGH —IN. SEE ARCHITECTURAL DRAWINGS FOR MOUNTING DETAIL ® LED LARGE PROJECTORS— PROVIDE 4° SQUARE J —BOX WITH COVER AT END OF 3/4" CONDUIT. SEE SHEET A4.1 FOR MOUNTING DETAIL PROVIDE J —BOX WITH WHIP TO ALLOW FLEXIBILITY FOR 20 DEGREE MOVEMENT. G.0 TO PROVIDE A/V VENDOR WITH PAINTED CROSS UNISTRUT PIECES. 0 SIMILAR TO NOTE #8 EXCEPT SMALL PROJECTOR TYPE. 0 4S JUNCTION BOX WITH 20A,120V DUPLEX OUTLET FOR PROJECTOR POWER IN 3/4" CONDUIT. MOUNT ON UNISTRUT FRAMING. 10 JUNCTION BOX FOR DATA CONNECTION TO PROJECTORS. MOUNT ON UNISTRUT SUPPORT. EXTEND CAT. 5E CABLE TO A/V RACK VIA CABLE TRAY IN 3/4" CONDUIT. SEE SHEET A4.1. 11 SPEAKER TYPE 'SP2', MOUNTED ON POST. SEE SHEET A4.0 FOR HEIGHT. @ PROVIDE JUNCTION BOX FOR CONNECTION TO SPEAKER TYPE 'SP1'. MOUNT ON UNISTRUT GRID. © PROVIDE JUNCTION BOX FOR CONNECTION TO SPEAKER TYPE 'SW. MOUNT TO UNISTRUT GRID. 14 SPEAKER TYPE SW,FLOOR MOUNTED SUBWOOFER ON FLOOR BELOW VIDEO SCREEN @ ROUTE CONDUIT FOR SUBWOOFERS ALONG KICKWALL G.C. TO RUN CONDUIT FROM SUBWOOFER LOCATION TO THE BACK OF THE THEATER ROOM WALL. 16 1/2 "C BY G.C. WITH SPEAKER WIRES BY AV VENDOR. 17 CABLE TRAY SYSTEM; SOLID BOTTOM "PAINT —READY PAN TRAY" CABLE TRAY STYLE, 9" WIDE X 4' HIGH /STEEL; "4LC" SERIES. LAYOUT AS SHOWN . GENERAL CONTRACTOR TO PROVIDE ALL NECESSARY COMPONENTS, CONNECTING /SPLICING HARDWARE FOR A COMPLETE SYSTEM. CABLE TRAY SHALL BE HUNG FROM STRUCTURAL CEILING USING TRAPEZE HANGERS, WITH 3/8' THREADED RODS EVERY 6'. MOUNTING HEIGHT TO BE PER ARCHITECTURAL DRAWINGS. MANUFACTURER SHALL BE B —LINE. CABLE TRAY SHALL BE PAINTED BLACK. CABLE TRAY RUNS SHALL BE JOINED WITH APPROVED FITTINGS FUNISHED BY B —LINE. BOND CABLE TRAY SYSTEM WITH 1 #6 /CU /GND TO BLDG. STEEL AT EACH ENDS. REFER TO ARCHITECTURAL DETAILS FOR EXACT LOCATION AND MOUNTING DETAILS. 18 CABLE TRAY SYSTEM; "BASKET STEEL WIRE" STYLE, 12 "WIDE X 2" HIGH. WALL MOUNTING, LENGTH AS SHOWN. PROVIDE ALL NECESSARY HARDWARE AND FITTINGS FOR A COMPLETE TRAY SYSTEM AS SHOWN. PROVIDE B —LINE CAT# FT212 —BLK. PROVIDE GROUND BONDING AS DESCRIBED UNDER NOTE #1. REFER TO THE ARCHITECTURAL DRAWINGS FOR EXACT LOCATION AND MOUNTING DETAILS. 19 REFER TO ARCHITECTURAL SHEETS FOR UNISTRUT DETAILS. 20 REFER TO SECURITY NOTES FOR MOTION DETECTOR INSTALLATION. 21 PROVIDE 1/2" CONDUIT LINK FROM 5— BUTTON OVERRIDE SWITCH IN BACK OF HOUSE TO OVERRIDE SWITCH AT REGISTER AND LIGHTING CONTROL PANEL SEE DETAIL 2 ON SHEET E1.3. @ PROVIDE JUNCTION BOX FOR CONNECTION TO SPEAKER TYPE 'SP3'. ROUTE CONDUIT TO NEAREST CABLE TRAY. ALARM GENERAL NOTES: 1. PLEASE FOLLOW MANUFACTURER'S INSTALLATION REQUIREMENTS AS THEY PERTAIN TO POWER. FOR ALL CONTROL PANEL GROUNDING, USE 14GA SOLID COPPER WIRE TO CONNECT TO CWP OR EQUIVALENT TERMINATION. 2. DO NOT CONNECT TELEPHONE LINE TO THE DIGITAL COMMUNICATOR UNTIL THE COMPLETED SYSTEM IS READY TO BE PROGRAMMED, THOROUGHLY TESTED AND PUT INTO SERVICE WITH THE MONITORING CENTER. 3. THE 110 BREAKER FOR THE EQUIPMENT MUST BE LOCKED OUT AT THE ELECTRICAL FUSE POWER PANEL 4. REMOTE PROGRAMMING WILL ONLY BE COMPLETED WHEN BOTH AC TRANSFORMER & DC BATTERY VOLTAGE SOURCES ARE PRESENT AT THE CONTROL PANEL 5. UPON COMPLETION OF INSTALLATION, TECHNICIANS MUST SUPPLY CSI WITH AS— BUILTS. PLEASE SEND MARKED PLANS TO YOUR INTERNAL CHECKPOINT PROJECT MANAGER. REVIEWED FOR COMPLIANCE WITH NFPA70 - NEC MAY :: 1 2011 City► ot•Tukw Ia BUILDING DIVISION CITY 0$ 111kagLA MAY 2 3 2011 PERMIT CENTER Linane /Drews Architects • 3500 West Burbank Blvd Second Floor Burbank, CA 91505 818.9725080 818.848.3895 Fax All information shown or described herein Is the property of Linane / Draws Architects, Incorporated; and shall not be reused, copied, or reproduced In any form without the express written authorization of Linane / Draws Architects, Incorporated. © Copyright: Linane /Draws Architects, Incorporated 2011 All rights reserved. dp DON PENN CONSULTING ENGINEER 635 WESTPORT PARKWAY, SUITE 800 GRAPEVINE: TEXAS 70051 817 - 410 -2655 FAX 817 -251 -8411 ISSUED FOR: DATE PRE BID /BLDG. DEPT. SUBMITTAL 03.25.11 BID /LL FINAL REVIEW 04.08.11 CONSTRUCTION SET 05.17.11 No. REVISION ISSUES: DATE WESTFIELD SOUTHCENTER SPACE # 592 536 SOUTHCENTER MALL TUKWILA, WA 98188 STORE NUMBER: 357 Drawn By DM A/E Job Number TD1102.00 Checked By KG File Name TD1102__E21 Project Mgr. DM Scale: Title: LOW VOLTAGE PLAN Sheet No. E2.1 TD1102_E21 PLOT DATE: 5.18.2011 TD1102_E30 PLOT DAiS: 6.1 12011 Linane /Drews Architects ,. - ' �' -' ' -- • °I } 0(9 401 r 3500 West Bur Blvd Burbank d Bur ank, C 91505 iiii. Secobnd Fl A _ LB -22 :,I i... Iv.,.6, L.. Inu.fl t n.f i II a L,. �I.: L I. 818848.3895 Fax .I1 .. :._._ ! I s i, :. .. i' . i�nf;T ual:,, I ,I :.,,�,.: ,7 , .,,rl,?GUli.f:b71:L�II,7tS 771;7T. .::.,� ,•74:: -,::. ;:::. i.::l , ,. ,. r, a .lu. ':', ,. I :: :: / -' / TELE !p , 29 ,'!J ! ... :.. LD -27 O® / i',' 18 i LB -7 22 A/V RACK Z,1 :; , ® , \ .. ...., � 7 ......... ...... ... ........... LB 7 ................._.. _ .. 18 ()LB -24 _..... -- LD -28 information shown or described herein is the property of L(nane / Draws Architects, Incorporated; and shall not be reused, copied, or reproduced In any form without the express written authorizat(on of Linane / Draws Architects, Incorporated. Copyright: none /Dr Architects, Incorporated © ht Linane/Drews to 2011 All righ served. is re \ \LB.. B - I L 7 / /, .................. .......................... w ........ LB 18,25,27, . % ! L6 -7 - " \ .. .... LD -17 . \\ 0 21 T / a_ , 1 ' O*°r;'y.!' 11 y jr � LB- \,\\\ y . LD -� s r �D � LD ID t7 ! � w k9° p � o `r � 1 '� �� O O P is p4 A. ' ;rr � FOR ELECTRICAL WORK 1 - '•.. ELECTRICA WOK N � <... :.. ,,,; � �,!/ \ � N��; .i I - - - - - -, CASHWRAP AREA SEE DETAIL 1 E1.2 \, ;;; ",. r ; r ....._� r : :..... .. #/ •,:n,:, 4LB / / '+9 IBUZZER l ++r +Ise' •, n • I •, � � ; i LD 5 - >.. \.\ LB-24 -18 LD- 23 �D _ I - dp DON PENN ENGINEE R OS�6 WE8 PORT PARKWAY. BWTE 800 On- 410- Z811i8FAX 261 -8411 „/ ,,, , COMMERCIAL GRADE PUSHBUTTON FOR ® +48 o "AFF ALB iii 0 I '� -1 LB -14 LA -42 100 AMP DISC FOR RTU 1 - ON ROOF S 1B � � LB- 37/39/41 GFI , V „ OD ® LL el ��' " 12 �� i \ ` \ LA -8 LB -24 LA -8 ISSUED FOR: DATE \, / _ LB 4 PRE BID BLDG. DEPT. SUBMITTAL 03.25.11 1 LB -20 LB -9 LB -23 LB 18' LB-5 / 0 BID /LL FINAL REVI EW 04.08.11 111 111!II / LB -8/10 , LD =1� i 1 I ri ■ LB�3 ,,,,� LD -21 , D LD -24 CONSTRUCTION SET 05.17.11 LB -6 - 'LB 2 D +x ,,,,,, � LD -22 / O / / LA -8 ` .. f / No. REVISION ISSUES: DATE BLDG. DEPT. RESUB. 05.17.11 , / / / / LA 8 LA 8 LB 24 i� LD-8 ' iii / /- i' i ! ,.././ / ii / , % LA -8 A , ;; / / � /' /` i j/ //% ALL OUTLETS IN SALES TO BE BLACK. OUTLETS IN B.O.H. TO BE WHITE. *OP.' 0 1 (op n , rr :' { ' ( tv: '' r «. (,.' S TO R E \ate • TO FONER PLAN 1/4 "_11-0" r1 20c1O2E30 FINISH PER ARCHITECTURAL QUIKRETE COMMERCIAL GRADE FAST SET CONCRETE (OR EQUIVALENT) AMS -3031 FLOOR LOOP ANTENNA FLOOR PVC SPACER TRAY & SHIELD TILES EXISTING SLAB \IOTES 6E1\ RAL __ \OTES 0 CONDUIT TO PULL UELECTRICAL/DA ELECTRICAL/DATA ES DOWN NTO�VENDOR PROVIDED JUNCTION INSIDE 1g MOUNT RECEPTACLE AT 9' -0" A.F.F. FOR FIXTURE LIGHTING, (1) RECEPTACLE PER 15' -0” MAX. S2° (MOUNT HORIZONTALLY). REFER TO DETAIL 3 ON SHEET E1.2. INSIDE FIXTURE. GC TO COORDINATE WITH VENDOR. 19 GFCI RECEPTACLE MOUNT AT +42 "AFF. VERIFY LOCATION PRIOR ROUGH -INS. ®20A,120V QUAD OUTLETS. SEE MANGER'S DESK DETAIL ON SHEET A7.3 FOR MOLNTING 20 20A,120V DUPLEX DEDICATED GROUND, SURGE SUPPRESSION OUTLET, HUBBELL CAT. # IG- 5362 -S. HEIGHTS. MOUNT AT 84" AFF. 3 30A,120V DOUBLE DUPLEX DEDICATED GROUND, SURGE SUPPRESSION OUTLET, HUBBELL 0 DUPLEX OUTLET MOUNTED IN HANDY BOX ON MONITOR SHELF AND IN ACCESSIBLE LOCATION. SEE CAT. # IG- 5362 -S AND NEMA L5 -30 PLUG WITH LOCKING RECEPTACLE CENTERED ABOVE ARCHITECTURAL DRAWINGS FOR MOUNTING DETAIL. ROUTE CONDUIT THROUGH WINDOW ACCESS CHANNEL, RACK AT 90 "AFF• SEE SHEET A5.2 (STOREFRONT DETAILS).; (2) 20A,120V DOUBLE DUPLEX ISOLATED GROUND, SURGE SUPPRESSION OUTLET, HUBBELL 22 QUAD RECEPTACLE TO BE MOUNTED ABOVE PLATFORM. CAT. # IG- 5362 -S AND NEMA L5 -20 PLUG CENTERED ABOVE RACK AT 90 "AFF. 23 PROVIDE (1) 4" JUNCTION BOXES MOUNTED ON UNISTRUT GRID AND PULL WIRE INSIDE 1/2" CONDUIT TO PULL ® GANG LOW VOLTAGE MOUNTING BRACKET FOR 4 DATA PORTS ARLINGTON INDUSTRIES ELECTRICAL WIRES DOWN TO VENDOR PROVIDED JUNCTION BOXES INSIDE FIXTURE. GC TO COORDINATE WITH VENDOR. CAT. # LV1. EXTEND 1 CONDUIT FROM MANAGER'S DESK TO A/V RACK. SEE SHEET A7.3 24 PROVIDE (2) 4" JUNCTION BOXES AND PULL WIRE INSIDE 1/2° FLEX CONDUIT TO PULL ELECTRICAL/DATA WIRES TO FOR MOUNTING HEIGHTS. VENDOR PROVIDED JUNCTION BOXES AT BASE OF FIXTURE. G.C. TO COORDINATE WITH VENDOR. ® JUNCTION BOX AND DISCONNECT SWITCH FOR CONNECTION TO EeMAX EX8208, 8.3KW, 208V INSTA -HOT ® 4S JUNCTION BOX WITH 2 DATA PORTS. EXTEND 1"CONDUIT FROM MANAGER'S DESK TO WATER HEATER. PROVIDE ALL CONNECTIONS COMPLETE. REFER EeMAX SHEET 208, FOR MOUNTING HEIGHT. A/V RACK. REFER TO SHEET A7.3 FOR MOUNTING HEIGHTS. ©NOT USED ON THIS PROJECT. 26 GC TO PROVIDE AN ACCESSIBLE DUPLEX 110V POWER AND ETHERNET CENTERED ON STOREFRONT PORTAL AND INSIDE STOREFRONT SOFFIT WITH CONDUIT BACK TO THE A/V RACK. COORDINATE LOCATION WITH 0 4' X 8' X 3/4" F.R. PLYWOOD FOR TELEPHONE TERMINAL BACKBOARD MOUNT AT 12" AFF STOREFRONT SECTIONS ON SHEET A5.1. TO TOP OF BOARD. BACKBOARD TO BE 1 HOUR TREATED, MIN. E.C. TO EXTEND 1'CONDUIT ONLY FROM LANDLORD BACKBOARD TO TENANT SPACE. E.C. TO PROVIDE 1/2 "C- 1#6 /CU GROUND 'MOM TBB TO BLDG STEEL. ®BUZZER AND TRANSFORMER, AT +96" PROVIDE EDWARDS CAT. 156G- 35G -24VAC CONTRACTOR TO PROVIDE ALL HARDWARE AND LABOR FOR A COMPLETE SYSTEM. ® JUNCTION BOX FOR CONNECTION TO EeMAX SP2412, 2.4KW, 120V INSTA -HOT WATER HEATER. PROVIDE ALL CONNECTIONS COMPLETE. 10 PROVIDE CHILDPROOF RECEPTACLES FOR CONVENIENCE OUTLET IN SALES AREA AT BASE OF WALL HUBBELL RR15SBKTR. BLACK COLOR (LION). REFER TO DETAIL 3 ON SHEET E1.2 FOR LOCATION. 11 ELECTRICAL PANELS, SEE SHEET E1.0 /SINGLE LINE DIAGRAM AND SCHEDULES FOR INFORMATION. 12 DUPLEX RECEPTACLE ABOVE DOOR AT 7' -6" A.F.F. ON BACKSTAGE SIDE FOR ACCESS POINT RECEIVER WITH 1/2" CONDUIT ABOVE THE DOOR FROM THE AV RACK. 13 DATA OUTLET FOR CONNECTION TO SHOPPER TRAK. EXTEND DISNEY STANDARD CAT 5E CABLE BACK TO DATA OUTLET AT A/V RACK. 14 1/2 "C WITH CAT. 5E CABLE TO JUNCTION BOX FOR SHOPPER TRAK. 15 FLUSH CEILING MOUNTED DUPLEX RECEPTACLE FOR SHOW WINDOW. VERIFY LOCATION PRIOR ROUGH -INS. COORDINATE WITH REFLECTED CEIUNG PLAN SHEET A4.0. 16 JUNCTION BOX WITH LEVER TYPE DISCONNECT FOR SIGN. VERIFY LOCATION PRIOR ROUGH -IN. 17 WALL MOUNT PHONE 1 ALL EMPTY CONDUIT SHALL BE PROVIDED WITH PULLSTRINGS. �„_ ___•__- //API 1 1111!%111Gff11Ul1IU111111�11♦I 11111E11 %7ZZ GENERAL CONTRACTOR TO PREPARE SLAB FOR SECURITY SYSTEM AS FOLLOWS: 1�� 1 LA — i � .. r1 .1 . 4' LI . ,l �' , WESTFIELD SOUTHCENTER SPACE # 592 536 SOUTHCENTER MALL TUKWILA, WA 98188 A. FLOOR CAVITY, SHOULD START 8 -12" BEHIND DOOR, GATE OR CRASHGATE. THE CAVITY HOUSES THE SENSORMAT1C AMS -3031 FLOOR LOOP ANTENNA. DIMENSIONS ARE: 2 -3/4" DEEP X 4' -6" WIDE X 14' -6" LENGTH B. IMPORTANT: IF SLAB CAN NOT BE SAW -CUT, THE FLOOR ATENNA WILL BE SURFACE MOUNTED USING THE AMS -2020 FLOOR LOOP ANTENNA. ALL OTHER SPECIFICATIONS AND DETAILS REMAIN THE SAME. THE SURFACE MOUNT f... ......... 2 -3/4" DEEP X 4: -6 WIDEX 14,,..6 " LENGTH / GENERAL CONTRACTOR TO PREPARE SLAB FOR SECURITY SYSTEM SEE NOTES BELOW: IF DOWELS ARE REQUIRED FIBER REINFORCED POLYMER (FBR) REBAR CAN BE USED REQUIRES A 3/8" TO 1/2" MORTAR BED. DUPLEX RECEPTACLE LOCATED WITHIN 1 FOOT OF NE POWER PACK. ELECTRICAL C. REQUIREMENTS ARE 110 V. AC, THREE WIRE, 24 HOUR CIRCUIT WITH SYSTEM/ C, T SECURITY SECTION I ION T ENTRY N.TS, �7� LESS THAN .5 V. AC BETWEEN NEUTRAL AND GROUND. CONTROLLER BOX 20 "L X17.1 "W X A DEDICATED 3 -WIRE, 24 -HOUR DUPLEX D. IF POWER PACK IS TO BE LOCATED IN CEILING THE CEILING HEIGHT CAN NOT EXCEED 12FT AFF. AN ACCESS PANEL OR CEIUNG TiLE IS REQUIRED NOT LESS THAN 18° SQUARE. 5.9 "D TO BE MOUNTED ABOVE RECEPTACLE WITH LESS THAN 0.5Vac CEILING. CONNECT TO CAPACITOR BETWEEN NEUTRAL AND GROUND "LX14.9'WX3.3 "D STORE NUMBER: QC�J 35 / E. AUDIBLE ALARM MAY BE INSTALLED UP TO 30' -0" FROM THE POWER PACK. CAPACITOR BOX 18.7 TO BE MOUNTED BOX WITH 3/4" CONDUIT. ABOVE CEILING. OR INSIDE PORTAL AS SPACE ALLOWS. THE CLOSER TO THE ANTENNA THE Drawn By DM A/E Job Number TD1102.00 F. 3/4" CONDUIT INTERCONNECT BETWEEN ANTENNA AND CAP BOARD BOX 3/4" CONDUIT BETTER PERFORMANANCE MINIMUN 7FT - MAXIMUM CABLE RUN FROM "A" ANTENNA TO CAPACITOR BOX IS 20' -0 ". CONDUIT STUBS -UP ON THE FRONT CORNER OF CAVITY, 7 FEET MINIMUM, 20 FEET MAXIMUM G. .MAX. CABLE RUN FROM °A" ANTENNA TO CAP BOARD BOX Checked By KG File Name TD1102 E30 IN SOFFIT OR SIDE WALL IS 20'-0" CASHWRAP NOTES: 1. TENANTS G.C. TO COORDINATE ACTUAL SENSORMATIC DETECTOR UNIT CASHWRAP COUNTERTOP CUT OUT LOCATIONS & QUANTITIES WITH THE DISNEY IN FIELD REPRESENTATIVE & SENSORMATiC CUT OUT TEMPLATE PRIOR TO CUTTING THE COUNTERTOP. AUDIBLE ALARM CONSOLE. VERIFY EXACT WALL INSTALLATION LOCATION WITH DISNEY STORE REPRESENTATIVE. MAX. 30' FROM POWER PACK. GC TO PROVIDE 3/4" CONDUIT & 4S JUNCTION BOX FLUSH WITH WALL ENTRY SOFFIT Iasi REVIEWED FOR COMPLIANCE WITH NFPA 70 NEC t� MAY `I 1 2011 Project Mgr. DM Scale: Title: POWER P �/'1' V PLAN .� �. %� .�� �. SLIDING GRILLE , ' ,,,, %� ``o) `�', ' `,, ; ' ,., ; ' �`. 2. SENSORMATIC CUT OUT TEMPLATE IS PROVIDED BY MILLWORK VENDOR LINE OF GYP. BD. INSIDE PORTAL 3/4" CONDUIT s City of Tukwila BUILDING DIVISION 3. TENANT GENERAL CONTRACTOR IS REQUIRED TO INSTALL SENSORMATiC UNITS IN CASHWRAP FOR SYSTEM RELEASE CONTACT: THOMAS LAROCCA 1- 914 - 624 -7680 FOR INSTALLATION CONTACT: SERVICE SUPPORT 1- 800 - 241 -6678 NOTE: SEE FLOOR PLAN ON SHEET A2.0 FOR EXACT STOREFRONT CONFIGURATION. PLAN SHOWN ABOVE IS A TYPICAL LAYOUT SHOWN FOR INFORMATIONAL PURPOSES ONLY. FINAL PLACEMENT OF ITEMS MAY VARY SIJGHTLY FROM CONFIGURATION SHOWN. RECEIVE2p. CITY OF TUKWILA MAY-237011 PERMIT CENTER Sheet o. A TENANT'S SIDE OF ENTRY SENSORMATIC ANTENNA BELOW STONE FLOOR 3•O SEGUE I TY NOTES "'T'S' N.T.S. %2� ELEVATION/ SECURITY SYSTEM TD1102_E30 PLOT DAiS: 6.1 12011