HomeMy WebLinkAboutPermit EL11-0394 - TUKWILA SOUTH - SEGALE PROPERTTUKWILA SOUTH SEGALE PROPERTIES SOUTHCENTER BL EL1 1 -0394 Parcel No.: 0322049006 Address: City* Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 -431 -2451 Web site: http: / /wwwci.tukwila.wa.us ELECTRICAL PERMIT Tenant Name: TUKWILA SOUTH - SEGALE PROPERTIES Permit Number: EL11 -0394 Issue Date: 05/16/2011 Permit Expires On: 11/12/2011 Owner: Name: Address: Contact Person: Name: Address: BARRY BENNETT PO BOX 88028 , TUKWILA WA 98188 Contractor: Name: WILSON CONSTRUCTION COMPANY Address: PO BOX 1190 , CANBY OR 97013 Contractor License No: WILSOCC066RK Phone: 206 - 396 -2012 Phone: 509 374 -1455 Expiration Date: 12/12/2012 DESCRIPTION OF WORK: INSTALL TEMPORARY POWER TO REGIONAL TESC POND #5. THIS IS A CONTINUATION OF PERMIT NO. EL 10 -080 (TUKVVILA SOUTH PROJECT). Value of Electrical Work: NRES: $12,500.00 RES: $0.00 Type of Fire Protection: NONE Electrical Service Provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: I hereby certify that I have read and governing this work will be complie Fees Collected: $395.13 National Electrical Code Edition: 2008 Date: ed this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. The granting of this permit does not pres construction or the performance of work. of this permit. Signature: en_, e to give authority to violate or cancel the provisions of any other state or local laws regulating I am authorized to sign and obtain this electrical permit and agree to the conditions on the back Date: 5- 25 -0 Print Name: fir 1/ an 018ccAy This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doe: EL -9/09 EL11 -0394 Printed: 05 -25 -2011 • • PERMIT CONDITIONS Permit No. EL11 -0394 * *ELECTRICAL ** 1: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 2: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 3: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 4: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 5: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 6: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. doc: EL -9/09 EL11 -0394 Printed: 05 -25 -2011 Site Address: CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 httal/www.ci.tukwita.wa.us ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** South of 200th Street and West of Frager RD Tenant Name: N/A Property Owners Name: Segale Properties LLC King Co Assessor's Tax No.: 03,2 yq / (.7,2: )4{9 ors Suite Number: N/A Floor: N/A New Tenant: ❑ Yes 0 .. No Mailing Address: PO Box 88028 Tukwila WA 98188 City State Zip CONTACT PERSON ' Who do w ct when your permit s ready to be issued Name: Barry Bennett Mailing Address: PO Box 88028 Day Telephone: (206) 396 -2012 Tukwila WA 98188 E -Mail Address: BBennett @segaleproperties.com City State Fax Number: (206) 575 -1662 Zip ELECTRICAL CONTRACTOR INFORMATION Company Name: Mailing Address: Bryan Moody PO Box 1190 Canby OR 97013 Contact Person: Bryan Moody E -Mail Address: Bmoody @wilsonconst.com Contractor Registration Number: WILSOC''"Z53'P3' LO(lU, t lL City State Day Telephone: (360) 280 -6152 Fax Number: (503) 263 -6946 Expiration Date: 07/07/2012 Zip Valuation of Project (contractor's bid price): $ 12,500 Scope of Work (please provide detailed information): Install temporary power to regional TESC pond #5. This is a continuation of permit # EL10 -0808. This is for the Tukwila South project. Will service be altered? ❑ Yes 10 No Type of Use: New lines will power TESC pond #5 Tvpe of work: VI New ❑ Addition ❑ Service Change ❑ Low Voltage ❑ Generator ❑ Fire Alarm Property Served by: m Puget Sound Energy ❑ Seattle City Light H:\Applications\Forms- Applications On Line\2010 Applications \7 -2010 - Electrical Permit Application.doc bh Page 1 of 2 Adding more than 50 amps? m Yes ❑ No ❑ Remodel ❑ Tenant Improvement ❑ Telecommunication VI Temporary Service RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $152.85 (including an attached garage) ❑ Garages, pools, spas and outbuildings $81.90 ea ❑ Low voltage systems (alarm, furnace thermostat) $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $81.90 (no added/altered circuits) ❑ Service change with added/altered circuits $81.90 number of added circuits $11.55 ea ❑ Circuits added/altered without service change $54.60 (up to 5 circuits) ❑ Circuits added/altered without service change $54.60 (6 or more circuits) $7.65 ea ❑ Meter /mast repair $68.25 ❑ Low voltage systems $59.85 (alarm, furnace thermostat) MULTI - FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $63.00 ❑ Temporary service (generator) $78.75 ❑ Manufactured/mobile home service $84.00 (excluding garage or outbuilding) ❑ Carnivals $78.75 Number of concessions $10.50 ea Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: Print Name: 17Gt l3€b\ Ae- Mailing Address: Bbennett@segaleproperties.com Date: 05/03/2012 Day Telephone: (206) 396 -2012 Tukwila WA City IDate Application Accepted: i4 1 Date Application Expires: 1I -4 -11 H:\ Applications\Forms- Applications On Line\2010 Applications \7 -2010 - Electrical Permit Application.doc bh Page 2 of 2 State 98188 Zip Staff Initials: r 1 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: Permit Number: EL11 -0394 Address: Status: PENDING Suite No: Applied Date: 05/04/2011 Applicant: SEGALE PROPERTIES - TUKWILA SOUTH Issue Date: Receipt No.: R11 -00889 Initials: BLH User ID: ADMIN Payment Amount: $395.13 Payment Date: 05/04/2011 01:01 PM Balance: $0.00 Payee: SEGALE PROPERTIES TRANSACTION LIST: Type Method Descriptio Amount Payment Check 629843 395.13 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR ELECTRICAL PLAN - NONRES 000.322.101.00.00 316.10 000.345.832.00.00 79.03 Total: $395.13 doc: Receiot -06 Printed: 05 -04 -2011 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -36 Permit Inspection Request Line (206) 431 -2451 INSPECTION RECORD Retain a copy with permit PERMIT Project- 14 5 __seat( Type of Inspection: 00 , Address: Date Called: Special Instructions: Date Wanted: t 6 1 a:m Requester: 77 Phone No: MApproved per applic}le code COMMENTS: r aCorrections required prior to approval. 1 ...,:...: • • -4 • J Y Inspector: Date: 17 1• n REINSPECTION FEE REQUIR D. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. • • • PE T PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL11 -0394 DATE: 05 -04 -11 PROJECT NAME: SEGALE SOUTH - TUKWILA PROPERTIES SITE ADDRESS: SOUTH OF 200 ST WEST OF FRAGER RD X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: ding Divi Is on Public Works Fire Prevention Structural n Planning Division Permit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete DUE DATE: 05 -05 -11 Not Applicable n Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route Structural Review Required No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 06-02-11 Approved Approved with Conditions ® Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip doc 2 -28 -02 Contractors or Tradespeople P ter Friendly Page • Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company WILSON CONSTRUCTION COMPANY 5032636882 1190 Nw Third Ave PO BOX 1190 Canby OR 97013 Out Of State Corporation UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 409008687 Active WILSOCC066RK Electrical Contractor 12/12/1994 12/12/2012 General Unused Electrical Administrator INFORMATION License SZENDM'055LC Name SZENDRE, MONTE Status Active Business Owner Information Name Role Effective Date Expiration Date C T CORPORATION, Agent 11/15/2002 5/19/2009 WILSON, DONALD M President 01/01/1980 $250.00 WILSON, KIM E Secretary 01/01/1980 ELECTRICAL CITATION WILSON, STACY A Treasurer 11/22/2004 3/8/2011 WILSON, NORMA E Vice President 01/01/1980 $250.00 SZENDRE, MONTE R Agent 01/01/1980 11/15/2002 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 3 WESTERN SURETY CO 58624396 12/07/2004 Until Cancelled $4,000.00 11/11/2004 Assignment of Savings Information No records found for the previous 6 year period Insurance Information No records found for the previous 6 year period Summons /Complaint Information Summons and Complaints are not filed with the department for this contractor type Warrant Information Warrants are not filed with the department for this contractor type Infractions /Citations Information Infraction / Citation Date RCW Code Type Status Violation Amount ECUNE00330 5/19/2009 19.28.101 RCW ELECTRICAL CITATION Satisfied $250.00 EHUDR00237 3/8/2011 19.28.101 RCW ELECTRICAL CITATION Satisfied $1,000.00 EHUDR00238 3/8/2011 19.28.101 RCW ELECTRICAL CITATION Satisfied $250.00 https: // fortress .wa.gov /lni/bbip/Print.aspx 05/25/2011 11:27am I: \Shared \NorthSky \A5 Engineering Work \Working \134000090__ — Segale_OH South of 200th NEW_NSE Design 04262011.dwg Apr 29,. 2011 Segale Properties -Phase II Customer Owned Temporary OH & UG Medium Voltage 12.5kV 3-PhaseLine Extension PLEASE NOTE: FOR INFORMATION NORTH OF THIS PROJECT PLEASE SEE SEGALE PROPERTIES - NORTH SKY WORK ORDER NUMBER 13400009032 or TUKWILA PERMIT NUMBER EL10 -0808 WORKZONE 1 POLES 14, 17 - 21 & VO4, V05 SEE SHEET 3 08 4 COMPREHENSIVE PROJECT OVERVIEW NOT TO SCALE LOAD DATA SCHEDULE - PHASE I CONSTRCUTION SEPARATE PERMIT REQUIRED FOR: I 'Mechanical ❑ Electrical ID� �Plumbing [,,, iaas Piping (7y of Tukwila DIVISION INSPECTOR NOTE: • CUSTOMER IS INSTALLING MOTORS THAT WILL CYCLE AND PUMP ON DEMAND ONLY AND ARE NOT CONTINUOUSLY RUNNING. LOAD DATA SCHEDULE - PHASE II CONSTRCUTION Service Phase and Voltage Panel Size Estimated Demand Factor Estimated kW Demand Per Panel Calculation Methodology Estimated kVA Required Per Panel Calculation Methodology NEW Proposed Transformer Size Transformer "V01" 30 480Y/277 100A 80% 100A X 1.73 X 480 X 95% 78888 79kW 100A X 480 X 1.73 83040 84kVA 112.5kVA = = 1000 1000 = 1000 1000 Transformer "V02" 30- 480Y/277 200A 80% 200A X 1.73 X 480 X 95% 157776 158kW 200A X 480 X 1.73 166080 167kVA 225kVA = = 1000 1000 = = 1000 1000 Transformer "V03" 30- 480Y/277 400A 80% 400A X 1.73 X 480 X 95% 315552 316kW 400A X 480 X 1.73 332160 333kVA 500kVA = = 1000 1000 = = 1000 1000 Total Estimated kW 553kW Total Estimated kVA 584kVA INSPECTOR NOTE: • CUSTOMER IS INSTALLING MOTORS THAT WILL CYCLE AND PUMP ON DEMAND ONLY AND ARE NOT CONTINUOUSLY RUNNING. LOAD DATA SCHEDULE - PHASE II CONSTRCUTION INSPECTOR NOTE: • CUSTOMER IS INSTALLING MOTORS THAT WILL CYCLE AND PUMP ON DEMAND ONLY AND ARE NOT CONTINUOUSLY RUNNING. PROJECT SCOPE OVERVIEW THIS PROJECT ENCOMPASSES THE DESIGN AND CONSTRUCTION OF A NEW 12,470 VOLT 3 -PHASE CUSTOMER OWNED MEDIUM VOLTAGE OVERHEAD AND UNDERGROUND FUSED DISTRIBUTION SYSTEM (3 -WIRE UNGROUNDED WYE AND A GROUND CONDUCTOR) TO SERVE THE STORM WATER PUMPS FOR THE SOUTHCENTER PARKWAY EXTENSION PROJECT, LOCATED IN TUKWILA, WASHINGTON. THE NEW 3 -PHASE OVERHEAD DISTRIBUTION SYSTEM STARTS AT THE LOAD -SIDE OF THE EXISTING UTILITY MASTER (PRIMARY) METER AND TERMINATES AT THE 600V SECONDARY TERMINAL BUS IN THE CUSTOMER OWNED TRANSFORMERS WHERE NORTH SKY'S ELECTRICAL DESIGN ENDS. SPECIFICALLY, THIS IS PHASE II OF THE PROJECT WHICH STARTS AT AN EXISTING POLE ON THE NORTH SIDE OF SOUTH 200TH STREET AND EXTENDS SOUTH APPROX. 1,220'. THE PROJECT CONSISTS OF INSTALLING 5 NEW FULLY PRESSURE TREATED WOOD POLES AND RESPECTIVE GUYING, ANCHORING AND GROUNDING. IT INCLUDES APPROX. 1,325 LINEAR FEET OF NEW #2 ACSR ( ALUMINUM CONDUCTOR STEEL REINFORCED) PRIMARY OVERHEAD CONDUCTORS, AND #2 ACSR PRIMARY GROUND IN THE HORIZONTAL (PRIMARY) POSITION. ALSO INCLUDED ARE (3) NEW 200 AMP FUSED DISCONNECTS FOR THE OVERHEAD TO UNDERGROUND TERMINATION ASSEMBLIES. FROM THE NEW 30 TERMINATIONS, THE NEW CUSTOMER OWNED MEDIUM VOLTAGE UNDERGROUND DISTRIBUTION SYSTEM WILL DISTRIBUTE VIA A 4" SCH40 DUCT SYSTEM WITH (3)1/0 CU. MV105 CABLES WITH A SEPARATE 600V COVERED GROUND IN THE SAME CONDUIT TO SERVE (2) NEW PAD MOUNTED 300KVA 480Y/277V PAD MOUNTED TRANSFORMERS (NEMA 3R, OUTDOOR, TYPE) WHICH WILL SET ON A CONCRETE LID AS INDICATED ON THE ENCLOSED DRAWINGS. POLES AND EQUIPMENT TO BE BUILT PER THE LOCAL UTILITY (PUGET SOUND ENERGY) STANDARDS FOR EASE OF FUTURE REPLACEMENT AND MAINTENANCE UNLESS OTHERWISE NOTED REVISIONS PROJECT CONTACT LIST No changes shall be made to the scope of Work without prior approval of SEGALE PROPERTIES Tukwila Building Division. "7: ; :visions will require a new plan submittal -,J may include additional plan review fees. 1 FILE COPY Permit No., CAA I 0 t11 Pte!t review approval is subject to errors and omission. of construction documents does not authorize fr►(, `4' olation of any adopted code or ordinance. Receipt of approved Field Copy and conditions is acknowledged: By 114 Date: 5 -2 s— 14 City Of Tukwila BUILDING DIVISION TABLE OF CONTENTS DESCRIPTION Service Phase and Voltage Panel Size Estimated Demand Factor Estimated kW Demand Per Panel Calculation Methodology Estimated kVA Required Per Panel Calculation Methodology NEW Proposed Transformer Size Transformer "VO4" 30- 480Y/277 300A 80% 300A X 1.73 X 480 X 95% : 236664 237kW 300A X 480 X 1.73 249120 250kVA 300kVA _ = 1000 1000 = = 1000 1000 Transformer "V05" 30- 480Y/277 300A 80% 300A X 1.73 X 480 X 95% 236664 237kW 300A X 480 X 1.73 249120 250kVA 300kVA = = 1000 1000 = = 1000 1000 Total Estimated kW 474kW Total Estimated kVA 500kVA INSPECTOR NOTE: • CUSTOMER IS INSTALLING MOTORS THAT WILL CYCLE AND PUMP ON DEMAND ONLY AND ARE NOT CONTINUOUSLY RUNNING. PROJECT SCOPE OVERVIEW THIS PROJECT ENCOMPASSES THE DESIGN AND CONSTRUCTION OF A NEW 12,470 VOLT 3 -PHASE CUSTOMER OWNED MEDIUM VOLTAGE OVERHEAD AND UNDERGROUND FUSED DISTRIBUTION SYSTEM (3 -WIRE UNGROUNDED WYE AND A GROUND CONDUCTOR) TO SERVE THE STORM WATER PUMPS FOR THE SOUTHCENTER PARKWAY EXTENSION PROJECT, LOCATED IN TUKWILA, WASHINGTON. THE NEW 3 -PHASE OVERHEAD DISTRIBUTION SYSTEM STARTS AT THE LOAD -SIDE OF THE EXISTING UTILITY MASTER (PRIMARY) METER AND TERMINATES AT THE 600V SECONDARY TERMINAL BUS IN THE CUSTOMER OWNED TRANSFORMERS WHERE NORTH SKY'S ELECTRICAL DESIGN ENDS. SPECIFICALLY, THIS IS PHASE II OF THE PROJECT WHICH STARTS AT AN EXISTING POLE ON THE NORTH SIDE OF SOUTH 200TH STREET AND EXTENDS SOUTH APPROX. 1,220'. THE PROJECT CONSISTS OF INSTALLING 5 NEW FULLY PRESSURE TREATED WOOD POLES AND RESPECTIVE GUYING, ANCHORING AND GROUNDING. IT INCLUDES APPROX. 1,325 LINEAR FEET OF NEW #2 ACSR ( ALUMINUM CONDUCTOR STEEL REINFORCED) PRIMARY OVERHEAD CONDUCTORS, AND #2 ACSR PRIMARY GROUND IN THE HORIZONTAL (PRIMARY) POSITION. ALSO INCLUDED ARE (3) NEW 200 AMP FUSED DISCONNECTS FOR THE OVERHEAD TO UNDERGROUND TERMINATION ASSEMBLIES. FROM THE NEW 30 TERMINATIONS, THE NEW CUSTOMER OWNED MEDIUM VOLTAGE UNDERGROUND DISTRIBUTION SYSTEM WILL DISTRIBUTE VIA A 4" SCH40 DUCT SYSTEM WITH (3)1/0 CU. MV105 CABLES WITH A SEPARATE 600V COVERED GROUND IN THE SAME CONDUIT TO SERVE (2) NEW PAD MOUNTED 300KVA 480Y/277V PAD MOUNTED TRANSFORMERS (NEMA 3R, OUTDOOR, TYPE) WHICH WILL SET ON A CONCRETE LID AS INDICATED ON THE ENCLOSED DRAWINGS. POLES AND EQUIPMENT TO BE BUILT PER THE LOCAL UTILITY (PUGET SOUND ENERGY) STANDARDS FOR EASE OF FUTURE REPLACEMENT AND MAINTENANCE UNLESS OTHERWISE NOTED REVISIONS PROJECT CONTACT LIST No changes shall be made to the scope of Work without prior approval of SEGALE PROPERTIES Tukwila Building Division. "7: ; :visions will require a new plan submittal -,J may include additional plan review fees. 1 FILE COPY Permit No., CAA I 0 t11 Pte!t review approval is subject to errors and omission. of construction documents does not authorize fr►(, `4' olation of any adopted code or ordinance. Receipt of approved Field Copy and conditions is acknowledged: By 114 Date: 5 -2 s— 14 City Of Tukwila BUILDING DIVISION TABLE OF CONTENTS DESCRIPTION SHEET TABLE OF CONTENTS COMPREHENSIVE PROJECT OVERVIEW PROJECT SCOPE PROJECT CONTACT LIST VICINITY MAP 1 GENERAL CONSTRUCTION NOTES ELECTRICAL SYMBOLS LEGEND • ABBREVIATION KEY 2 SITE PLAN WORKZONE 1 CONSTRUCTION NOTES 3 ONE -LINE CIRCUIT SCHEMATIC ONE -LINE CONDUIT AND CABLE DIAGRAMS TRENCH DETAIL CABLE TAG DETAIL 4 POLE DETAILS TRANSFORMER DETAILS 5 TECHNICAL SCHEDULES 6 PRO 1 REVIEWED FOR COMPLIANCE OC N�WCITH MAY 122011 t1.37Ci of .Tukwila BUILDING DIVISION l;, 5 .1ZOTH 5171St ST .172ND'. MARIO SEGALE MARK SEGALE TODD COVEY OWNER OWNER PROJECT MANAGER (206) 575 -2000 (206) 575 -2000 (206) 575 -2000 NORTH SKY ENGINEERING (PRIVATE MV ELECTRIC SYSTEM) CLINT TH■YER - ENGINEER - (425) 864 -0566 5 1:5100 173RD$ Q;3: <ST`, 5 1.1311,1 511 26 C CORPORAT_ n DR .N m %D MINKLER I1. J%� Q' � WI' r I i -cH. � JSjLH$A � 1 GREEYAFI r \ -PARK ST 1. s `T 50Th 4QW . �s .r,ls IOW is `� L L 0110178TH" .BON 5 SO- __,__�i 174tH to- ,LANDS t 's I sw . ST a� 41 1'I SW 38TH ST RENTON WETLANDS L - TR1l1AND bR 5E00 S L_ LA SW 43RD 5T 19151 ST s 118280 ST fi"SPRI NC,9,R ppl(,ni GREENBELIT 7550/7/5 INPLA 8111118. BY M RRIOTT S^ ti> o CUR ST 190TH .6800 �T S 191ST PL S 1193RD. f rL 5600 196TH 182ND ST 184TH ST 186TH ---Pt 5.188TH ST 190TH_ST — S- 192ND ST o s 194TH c° Si j ST 200TH :204TH ST NGINEERING A `u, UANTA SERVICES COMPANY 2224 104th Avenue East Suite 1 Edgewood, WA 98372 Office (253) 952 -2128 Fax (253) 952 -2140 13400009037 NSC Job Number: Clint Thayer Engineer. Clint Thayer Drafter. Barry Eronson Checked: Wayne Hagan Approved: . _. -; w I S'F ?: 07 (iG�`f C?\ . 1 302.3? • „;r Y,..16-+ c /2 q /il EXPIRES 11/19/ Z.0 11 Revisions No. Date Description Segale Properties Phase 11 Customer Owned Temporary OH & UG Medium Voltage 12.5kV 30 Line Extension From South 200th Street, South to just North of South 204th Street ECEIVED MAY 04 20i1. RMIT CENTE S - - 1 16 08TH ST 5 209TH ST+ 1I 0L420o S: . <.Z16 i 216TH ST VICINITY MAP NOT TO SCALE 12 0 I 1 IV 216TH 039'1 Cover Sheet Project Overview Project Scope Table of Contents Contact List Vicinity Map Sheet 1 of 6 11:28am I: \Shared \NorthSky \A5 Engineering Work \Working \134000090__ — Segale_OH South of 200th\ NEW_NSE Design 04262011.dwg GENERAL CONSTRUCTION NOTES PRE - CONSTRUCTION: • AN ON -SITE PRE CONSTRUCTION MEETING IS REQUIRED PRIOR TO THE START OF CONSTRUCTION. THE PROJECT ENGINEER WILL BE SCHEDULED TO ATTEND THIS MEETING TO PROVIDE INPUT AND CLARIFICATION. • LOCATE & MARK ALL UTILITIES PRIOR TO CONSTRUCTION, UTILIZING THE LOCAL "ONE- CALL" SYSTEM AND ANY UTILITIES WHICH DO NOT PARTICIPATE OR "PRIVATE LOCATORS ". PERMIT REQUIREMENTS: • PRIOR TO CONSTRUCTION, CONTRACTOR SHALL SECURE ALL NECESSARY CONSTRUCTION PERMITS DEEMED NECESSARY . • NOTIFY LOCAL L &I AUTHORITIES 48 TO 72 HOURS OR AS REQUIRED BY PERMITTING AGENCY BEFORE STARTING WORK. QUALIFIED WORKERS: • ALL CONSTRUCTION SHALL BE PERFORMED BY QUALIFIED ELECTRICAL WORKERS. SAFETY: • EMPLOYEES SHALL ADHERE TO ALL SAFETY REQUIREMENTS AT ALL TIMES • USE PROPER VEHICLE GROUNDING AND BARRICADING PER STATE AND FEDERAL REQUIREMENTS. • SYSTEM GROUNDING REQUIREMENTS, PER STATE AND FEDERAL CODES SHALL BE USED. • PERSONAL PROTECTIVE GROUNDING REQUIREMENTS, PER STATE AND FEDERAL CODES SHALL BE USED. WORKING DRAWINGS: • LOCATIONS OF EXISTING FEATURES AND FACILITIES ARE BASED ON DRAWINGS PROVIDED BY THE OWNER. FIELD VERIFICATION SHOULD BE MADE BEFORE STARTING PROJECT. • MAINTAIN ON SITE, IN GOOD CONDITION, A COMPLETE FILE OF CONSTRUCTION DRAWINGS. • THESE DRAWINGS SHALL BE AVAILABLE AT ALL TIMES TO THE OWNER'S SITE REPRESENTATIVE, AND THE ELECTRICAL INSPECTOR. • CORRECTIONS AND CHANGES MADE DURING CONSTRUCTION SHALL BE RECORDED CONTINUOUSLY ON THESE DRAWINGS. • ANY CHANGES TO THIS DESIGN SHALL FOLLOW NOTIFICATION AND APPROVAL FROM THE OWNER OR THE DESIGN ENGINEER PRIOR TO ANY CONSTRUCTION REVISIONS. MATERIAL: • ALL MATERIALS SHALL BE UL LISTED AND RATED IN COMPLIANCE WITH NEC, NESC AND ANSI STANDARDS. • OVERHEAD PRIMARY AND SYSTEM GROUNDING CONDUCTORS SHALL CONSIST OF #2 ACSR (PHASES) AND #2 ACSR GROUND. (MULTI- GROUNDED AT EACH POLE) • UNDERGROUND MEDIUM VOLTAGE CONDUCTORS TO CONSIST OF (3) 1/0 STRANDED C.U. MV -105 EPR 15kV RATED JACKETED 133% INSULATED, AND (1) COVERED #2 STRANDED C.U. MULTI - GROUNDED 600V INSULATED COVERED (THHW) GROUND CONDUCTOR. EXCAVATION, FRAMING & INSTALLATION OF WOOD POLES: • POLE EXCAVATIONS SHALL BE MAINTAINED IN A SAFE CONDITION AT ALL TIMES TO PROTECT THE WORKERS. • OPEN EXCAVATIONS LEFT OPEN OVERNIGHT OR NON WORKING DAYS SHALL BE COVERED OR SECURED BY MEANS ACCEPTABLE TO THE OWNER. • EXCAVATION IN EARTH SHALL HAVE CLEAN LEVEL SURFACES OF UNDISTURBED MATERIAL WITH ADEQUATE BEARING CAPACITY. • POLES ARE TO BE INSTALLED OR RELOCATED AS STAKED. UNLESS OTHERWISE NOTED, ALL POLE LOCATION MEASUREMENTS ARE FROM THE CENTER OF THE POLE. • NEW POLES SET SHALL BE THE CLASS INDICATED ON THE SKETCH, OR BETTER. • POLES AND ANCHORS WILL BE STAKED PRIOR TO CONSTRUCTION. • ALL POLE TO BE SET AT 10% +2' UNLESS OTHER WISE INDICATED. • IF SOIL IS UNSUITABLE FOR BACK -FILL AROUND POLES, USE 5/8" CRUSHED ROCK. • TREAT HOLES DRILLED IN THE FIELD WITH COPPER NAPHTHENATE. • IF POSSIBLE, ORDER POLES PREDRILLED AND FULLY TREATED FROM THE MANUFACTURE. • FRAME POLES PER LOCAL UTILITY STANDARDS FOR EASE OF REPLACEMENT IN THE CASE OF EMERGENCY. SEE FRAMING DETAILS. • APPLY GRIT INHIBITOR ON ALL STIRRUP, AND DEAD -END CONNECTIONS. • ALL GROUND CONDUCTOR CONNECTIONS TO BE MADE WITH SOLID COMPRESSION CONNECTORS. CONNECT ALL POLE GROUNDS TO COMMON NEUTRAL. • ALL PRIMARY AND SYSTEM GROUND CONDUCTORS SHALL BE PULLED IN USING THE APPROPRIATE RULING SPAN AND SAG TABLES PROVIDED ON THE DESIGN. • ALL CONNECTIONS TO THE SYSTEM GROUND CONDUCTOR WIRE WILL BE COMPRESSION TYPE PRESSED CONNECTIONS FOR EFFECTIVE BONDING GUYING: • DEAD ENDING THE PRIMARY AND GROUND CONDUCTORS REQUIRES MULTIPLE 3/8" GUYS WITH A MINIMUM LEAD OF 20', UNLESS OTHERWISE NOTED. • ANCHORS TO BE TRIPLE -HELIX SCREW IN TYPE WITH A 1 1/2" ROD EXTENSIONS . • YELLOW PLASTIC GUY GUARDS TO BE ON ALL DOWN GUYS. (FROM GROUND LEVEL UP TO 8' ABOVE GRADE) EQUIPMENT, VAULTS, ETC.: • EQUIPMENT, EQUIPMENT PADS, SPLICE VAULTS, PEDESTALS, ETC. SHALL BE INSTALLED PLUMB AND TRUE, AND SHALL BE SQUARE WITH THE ADJACENT STREETS, SIDEWALKS, PROPERTY LINES, ETC. THE LOCATION OF SIMILAR ITEMS SHALL BE CONSISTENT. • EQUIPMENT, EQUIPMENT PADS, SPLICE VAULTS, PEDESTALS, ETC, BEDDING MATERIAL SHALL CONSIST OF A MINIMUM OF 3 TO 6 INCHES. USE 5/8" MINUS CRUSHED ROCK. BACKFILL SHALL BE GOOD COMPATIBLE MATERIAL WITHOUT LARGE ROCKS, CHUNKS OR STICKS. BACKFILL SHALL BE PROGRESSIVELY COMPACTED FROM THE BOTTOM TO THE TOP SURFACE, AND SHALL BE WITHOUT VOIDS. • CONDUIT AND CABLE ENTRANCES, ETC. SHALL BE SUITABLY SEALED AND /OR GROUTED TO MAINTAIN THE INTEGRITY OF THE CONDUIT SYSTEM. • ALL VAULTS SHALL BE PRECAST CONCRETE, WITH ONE -PIECE COVER, LOCKING GALVANIZED STEEL ENTRANCE HATCH, KNOCKOUTS, DRAINS, EMBEDDED CHANNELS, ETC. • MEDIUM VOLTAGE CABLE TERMINAL BLOCKS (JUNCTION BOXES) SHALL BE 15 kV, 4 POINT LOAD BREAK CONNECTORS FOR USE WITH ELBOW TYPE HOT -STICK OPERABLE DEVICES WITH TEST POINTS (SEE HIGH VOLTAGE CABLE SECTION FOR TYPE), WALL MOUNTED WITH MOUNTING BRACKETS, 2 GROUND LUGS AND A MINIMUM OF 2 PARKING STANDS. MOUNTING HARDWARE, ETC. SHALL BE STAINLESS STEEL. ELASTIMOLD 163J4R -7 STAINLESS STEEL, OR APPROVED EQUAL. • TRANSFORMER PADS SHALL BE PRE -CAST CONCRETE, MINIMUM 6" THICK, SIZE AS REQUIRED WITH CABLE ENTRANCE OPENING(S) TO MATCH EQUIPMENT. CONDUITS: • CONDUITS SHALL BE SCHEDULE 40 PVC OR BETTER, FLAME RETARDANT, SUITABLE FOR USE WITH 90 °C CABLE, SHALL NOT DISTORT FROM HEAT IT WILL NORMALLY ENCOUNTER AND SHALL BE RESISTANT TO LOW TEMPERATURE AND SUNLIGHT EFFECTS, IMPACT AND CRUSHING. FITTINGS, COUPLINGS, ETC. SHALL BE OF THE SAME MANUFACTURER AS THE CONDUIT. ELECTRICAL POWER CONDUITS TO BE ELECTRICAL GRAY IN COLOR. • CONDUITS SHALL BE INSTALLED WITH A MINIMUM 36" COVER TO FINAL GRADE UNLESS OTHERWISE NOTED IN PLANS. • JOINTS IN THE UNDERGROUND PVC CONDUIT SYSTEM SHALL BE SOLVENT WELDED TO PREVENT THE ENTRANCE OF MOISTURE. PRIOR TO APPLYING SOLVENT, CONDUITS ENDS AND CONNECTORS SHALL BE PREPPED WITH PURPLE ETCHING PRIMER. • POWER CONDUIT ELBOWS AND BENDS SHALL BE MINIMUM 36 INCH RADIUS WHEN CONTAINING 15 kV CABLES AND MINIMUM 24" RADIUS WHEN CONTAINING 600 VOLT CABLES. • ALL CONDUIT ENTRIES INTO VAULTS TO BE MORTAR GROUTED AND SMOOTHLY FINISHED. CONDUITS TO ENTER AT A PERPENDICULAR (90) ANGLE TO VAULT FACE. • ALL CONDUITS IN TRENCH TO BE INSPECTED PRIOR TO BACKFILL FOR CORRECT DEPTH, SEPARATION SAND - BEDDING AND COVER. PRIMARY POWER CABLES: • PRIMARY POWER CABLES SHALL BE 15 kV UNDERGROUND RESIDENTIAL DISTRIBUTION (URD) CABLE, MV -105, COPPER, CLASS B STRANDED (COMPACTED) WITH AN EXTRUDED ETHYLENE PROPYLENE RUBBER (EPR) SEMI - CONDUCTING STRESS CONTROL LAYER OVER THE CONDUCTOR, MINIMUM 220 MIL EPR INSULATION (133% INSULATION LEVEL), EPR SEMI - CONDUCTING INSULATION SHIELD, AND HMW BLACK POLYETHYLENE COMPOUND OUTER JACKET. • PRIMARY POWER CABLES SHALL BE SUITABLE FOR INSTALLATION IN UNDERGROUND CONDUIT AT MAXIMUM CONDUCTOR TEMPERATURES OF 105 °C FOR CONTINUOUS NORMAL OPERATION, 130 °C FOR EMERGENCY OVERLOAD CONDITIONS AND 250 °C FOR SHORT CIRCUIT CONDITIONS. • PRIMARY POWER CABLES SHALL BE FACTORY TESTED IN ACCORDANCE WITH THE REQUIREMENTS OF ICEA AND AEIC, AND INCLUDE WITH EACH SHIPMENT OF CABLE A CERTIFIED TEST REPORT IN DUPLICATE TOGETHER WITH A STATEMENT THAT THE CABLE MEETS ALL THE REQUIREMENTS OF THIS SPECIFICATION AND INDUSTRY STANDARDS. • PRIMARY POWER CABLE TERMINATIONS AT TRANSFORMERS, SPLICE VAULTS, ETC. SHALL BE MADE WITH DEAD -END SUBMERSIBLE, HOT -STICK OPERABLE 200 AMP, 8.3/14.4kV LOAD BREAK ELBOW TYPE TERMINATORS WITH TEST POINTS. TERMINATORS SHALL BE MOLDED OF EPDM RUBBER ENCLOSED IN A MOLDED SEMI - CONDUCTIVE JACKET THAT IS GROUNDED DURING OPERATION, AND PROVIDED WITH A STAINLESS STEEL REINFORCED PULLING EYE. ELASTIMOLD TYPE 166LR, OR APPROVED EQUAL; COMPLETE WITH ALL NECESSARY COMPONENTS AND /OR ACCESSORIES TO MAKE UP A COMPLETE AND OPERATIONAL SYSTEM. • CABLE PULLING LUBRICANTS SHALL BE OF THE BEST QUALITY AND SHALL HAVE NO DAMAGING EFFECT ON THE INSULATION AND CABLE JACKET. • INSTALLATION OF ALL NEW MEDIUM VOLTAGE CABLE SHALL BE MEASURED AND RECORDED WITH A CALIBRATED TENSION DEVICE AND SHALL NOT EXCEED THE MANUFACTURER'S MAXIMUM ALLOWABLE PULLING TENSION, SIDEWALL PRESSURE AND BENDING RADIUS. THE RECORDED TENSIONS CAN BE DIGITAL AND OR MANUAL. GROUNDING: • GROUND RODS TO BE 3/ INCH DIAMETER BY 8 FEET LONG COPPER -CLAD STEEL. • THE MULTI - GROUNDED NEUTRAL CONDUCTOR SHALL BE 600V RATED CABLE, COPPER, CLASS B STRANDED (COMPACTED), WITH POLYETHYLENE COMPOUND OUTER JACKET (THHW) IN THE SAME CONDUIT AS THE PRIMARY CABLES. BLACK INSULATION WITH GREEN PHASE TAPE ON EXPOSED SECTION AT EACH END. • BEFORE GROUNDING CONNECTIONS ARE MADE, CONTACT SURFACES SHALL BE THOROUGHLY CLEANED. CONNECTIONS SHALL BE BOTH MECHANICALLY AND ELECTRICALLY SECURE. • INSTALL A GROUND MAT IN THE VICINITY OF ALL 600 AMP GANG OPERATED SWITCH HANDLES AND BOND TO GROUND LOOP. • GROUND RODS SHALL BE DRIVEN AT OPPOSITE CORNERS AT EACH VAULT AND VISIBLE FOR INSPECTION. THE SEPARATION DISTANCE BETWEEN GROUND RODS TO BE A MINIMUM 6 FEET • CONNECTIONS AT GROUND RODS SHALL BE INSTALLED PER MECHANICAL CONNECTIONS WITH A #2 CU BARE GROUND WIRE ENTERING EACH VAULT AND BONDED TO THE GROUND LOOP INSIDE. TESTING: • ALL ELECTRICAL ACCEPTANCE TESTING TO BE PERFORMED BY A VERIFIED TESTING TECHNICIAN OR TESTING ENGINEER. • ALL ELECTRICAL ACCEPTANCE TESTING OF EQUIPMENT, APPARATUS AND MATERIAL TO BE PERFORMED IN ACCORDANCE WITH THE MOST CURRENT N.E.T.A. TESTING STANDARDS, REQUIREMENTS AND PRACTICES. • ALL UL EQUIVALENCY TESTING I.E. 'FIELD CERTIFICATION' TESTING TO BE PERFORMED BY A QUALIFIED AND REGISTERED TESTING COMPANY AND TESTING ENGINEER. ELECTRIC SYMBOLS LEGEND • NEW 30 TRANSFORMER / PADMOUNT PSE PRIMARY METERING POINT 30 600A DISCONNECT SW G/O 15 kV RATED 'LOAD BREAK' —t— OVERHEAD FUSE DISCONNECT SWITCH (SINGLE THROW SINGLE POLE) —G —G — A • O DOWN GUY & ANCHOR NEW OVERHEAD OR UNDERGROUND DISTRIBUTION SYSTEM EXISTING OH UTILITY PRIMARY SYSTEM GROUND LOOP IN VAULT, # 2 CU. BARE SOLID NEW OH TO UG TERMINATION FUSES NEW POLE EXISTING POLE WOOD POLE PUSH BRACE ABBREVIATIONS kV 30 AAC ACSR ANCH ASSY AWG CIR C/O CU DBL DE , FPT G/O MOV MP MV OH PRI SCH. SEC SVC SW TYP TW UG XFMR - 1,000 VOLTS THREE PHASE - ALL ALUMINUM CONDUCTOR ALUMINUM CONDUCTOR STEEL REINFORCED ANCHOR ASSEMBLY AMERICAN WIRE GAUGE - CIRCUIT CUT -OUT (FUSED) - COPPER - DOUBLE DEAD END FULLY PRESSURE TREATED - GANG- OPERATED METAL OXIDE VARISTOR METERING POINT - MEDIUM VOLTAGE OVERHEAD PRIMARY 30 (12,470 VOLTS 0 TO 0 AND 7,200 VOLTS 0 TO GROUND) SCHEDULE - SECONDARY / LOW VOLTAGE 480Y/277 30 LESS THAN 600 VOLTS - SERVICE - SWITCH TYPICAL TREE WIRE - UNDERGROUND TRANSFORMER REVIEWED FOR Y COMPLIANCE 0� NECTH MAY 12 2011 City of Tukwila BUILDING DIVISION RECEIVED MAY 0 4 2011 PERMIT CENTER EL\kO3P- A t'� UANTA SERVICES COMPANY 2224 104th Avenue East Suite 1 Edgewood, WA 98372 Office (253) 952 -2128 Fax (253) 952 -2140 13400009037 NSC Job Number: Clint Thayer Engineer. Clint Thayer Drafter. Barry Eronson Checked: Wayne Hagan Approved: ''N' , . , 30331 1 f 0NA L, ,♦ /2 9/// EXPIRES 11/13/ 2O // Revisions No. Date Description Segale Properties Phase 11 Customer Owned Temporary OH & UG Medium Voltage 12.5kV 30 Line Extension From South 200th Street, South to just North of South 204th Street General Notes Electrical Symbols Legend Abbreviation Key Sheet 2 of 6 rn -o 0 N 0 . _ Q) 0 w 1 w z s 0 0 0 0 0 I 0 on 0 0•) 0 0 0 0 ro 0' 0 rn .17 .61 C w U7 s 0 z a) 0 s E 0 SPECIFIC OH SITE CONSTRUCTION NOTES P14 - (Customer Pole) - - EXISTING 45' CLASS 3 PRIMARY POLE EXISTING 10' 8 PIN SINGLE LINE ARM INSTALL 10' 8 PIN DOUBLE LINE ARMS (IN THE BUCK POSITION) INSTALL (3) #2ACSR ARM MOUNTED FULL TENSION DEADENDS (SOUTH TO "P17 ") INSTALL (1) #2ACSR ARM MOUNTED FULL TENSION OH GROUND CONDUCTOR DEADEND (SOUTH TO "P17 ") INSTALL (2) 3/8" PRIMARY DOWN GUY ASSEMBLIES (NORTH L =15') INSTALL 10" TRIPLE HELIX ANCHOR (NORTH ) FOREMAN NOTE: HORIZONTAL CONSTRUCTION FOR ADDED CLEARANCE P17 - (Customer Pole) - INSTALL 60' CLASS 3 PRIMARY POLE INSTALL 10' 8 PIN DOUBLE LINE ARMS INSTALL (3) #2ACSR ARM MOUNTED FULL TENSION DEADENDS (NORTH TO "P14 ") - INSTALL (1) #2ACSR ARM MOUNTED FULL TENSION OH GROUND CONDUCTOR DEADEND - INSTALL 10' 8 PIN DOUBLE LINE ARMS (IN THE BUCK POSITION) - INSTALL (3) #2ACSR ARM MOUNTED FULL TENSION DEADENDS (SOUTHEAST TO "P18 ") - INSTALL (1) #2ACSR ARM MOUNTED FULL TENSION OH GROUND CONDUCTOR DEADEND - INSTALL (2) 3/8" PRIMARY DOWN GUY ASSEMBLIES (SOUTH L =15') - INSTALL 10" TRIPLE HELIX ANCHOR (SOUTH) - INSTALL (2) 3/8" PRIMARY DOWN GUY ASSEMBLIES (NORTHWEST L =15') INSTALL 10" TRIPLE HELIX ANCHOR (NORTHWEST) FOREMAN NOTE: HORIZONTAL CONSTRUCTION FOR ADDED CLEARANC E P18 - (Customer Pole) - INSTALL 60' CLASS 3 PRIMARY POLE INSTALL 10' 8 PIN DOUBLE LINE ARMS INSTALL (3) #2ACSR ARM MOUNTED FULL TENSION DEADENDS (NORTHWEST TO "P17 ") INSTALL (1) #2ACSR ARM MOUNTED FULL TENSION OH GROUND CONDUCTOR DEADEND INSTALL 10' 8 PIN DOUBLE LINE ARMS (IN THE BUCK POSITION) INSTALL (3) #2ACSR ARM MOUNTED FULL TENSION DEADENDS (SOUTH TO "P19 ") INSTALL (1) #2ACSR ARM MOUNTED FULL TENSION OH GROUND CONDUCTOR DEADEND INSTALL (2) 3/8" PRIMARY DOWN GUY ASSEMBLIES (SOUTHEAST L =15') INSTALL 10" TRIPLE HELIX ANCHOR (SOUTHEAST) INSTALL (2) 3/8" PRIMARY DOWN GUY ASSEMBLIES (NORTH L =15') INSTALL 10" TRIPLE HELIX ANCHOR (NORTH) FOREMAN NOTE: HORIZONTAL CONSTRUCTION FOR ADDED CLEARANC E P19 - (Customer Pole) - INSTALL 60' CLASS 3 PRIMARY POLE INSTALL 10' 8 PIN SINGLE LINE ARM INSTALL (3) 13kV RATED ARM MOUNTED PIN INSULATORS INSTALL (1) 8kV RATED ARM MOUNTED PIN INSULATOR FOR THE OH GROUND CONDUCTOR FOREMAN NOTE: HORIZONTAL CONSTRUCTION FOR ADDED CLEARANCE NORTH TO "P14 ") SOUTHEAST TO "P18 ") (NORTHWEST TO "P17 ") (SOUTH TO "P19 ") —4- SITE PLAN VIEW - WORKZONE 1 SCALE: 1" = 60' 50° L 1 1 1 1 1 —1 1 1 35 °L 00+01 SOUTHCENTER PARKWAY oo+ aI 00+oa1 45 °L SPECIFIC OH SITE CONSTRUCTION NOTES P20 - (Customer Pole) - - INSTALL 60' CLASS 3 PRIMARY POLE - INSTALL 10' 8 PIN SINGLE LINE ARM INSTALL (3) 13kV RATED ARM MOUNTED PIN INSULATORS FOREMAN NOTE: HORIZONTAL CONSTRUCTION FOR ADDED CLEARANC E - INSTALL FIBERGLASS TRI -UNIT ARM - INSTALL 30 1/0 CU MV105 -EPR PRIMARY TERMINATION ASSEMBLY (TO "VO4 ") - INSTALL (3) 10kV METAL OXIDE VARISTOR (MOV) - INSTALL (3) LOAD - INTERUPTER CUTOUTS AND FUSE AT 40T FOREMAN NOTE: INSTALL SWITCH NUMBER SW07 - INSTALL (1) 4" PRIMARY RISER ASSEMBLY (FULL W/ NEW 30 15kV 1/0 CU MV105 -EPR CABLES) P21 - (Customer Pole) - INSTALL 60' CLASS 3 PRIMARY POLE INSTALL 10' 8 PIN DOUBLE LINE ARMS INSTALL (3) #2ACSR ARM MOUNTED FULL TENSION DEADENDS (NORTH TO "P21 ") INSTALL (1) #2ACSR ARM MOUNTED FULL TENSION OH GROUND CONDUCTOR DEADEND (NORTH TO "P21 ") INSTALL (2) 3/8" PRIMARY DOWN GUY ASSEMBLIES (SOUTH L =15') INSTALL 10" TRIPLE HELIX ANCHOR (SOUTH) FOREMAN NOTE: HORIZONTAL CONSTRUCTION FOR ADDED CLEARANC E - INSTALL FIBERGLASS TRI -UNIT ARM - INSTALL 30 1/0 CU MV105 -EPR PRIMARY TERMINATION ASSEMBLY (TO "VO4 ") - INSTALL (3) 10kV METAL OXIDE VARISTOR (MOV) - INSTALL (3) LOAD - INTERUPTER CUTOUTS AND FUSE AT 40T FOREMAN NOTE: INSTALL SWITCH NUMBER SW08 - INSTALL (1) 4" PRIMARY RISER ASSEMBLY (FULL W/ NEW 30 15kV 1/0 CU MV105 -EPR CABLES) SPECIFIC UG SITE CONSTRUCTION NOTES VO4 - INSTALL 4'- 8 "X5' -6 "X6" COVER WITH 20 "X44" XFMR ACCESS HOLE INSTALL 30 300kVA PADMOUNTED TRANSFORMER 480Y/277 INSTALL (3) LOAD -BREAK ELBOWS INSTALL (2) 8'x3/4" DRIVEN GROUND RODS PLUMB (1) 4" SCH40 PVC 20' TO "P20" (CONDUIT FULL WI 30 15kV 1/0 CU JACKETED CABLES) V05 - SPECIFIC UG SITE CONSTRUCTION NOTES INSTALL 4'- 8 "X5' -6 "X6" COVER WITH 20 "X44" XFMR ACCESS HOLE INSTALL 30 300kVA PADMOUNTED TRANSFORMER 480Y/277 INSTALL (3) LOAD -BREAK ELBOWS INSTALL (2) 8'x3/4" DRIVEN GROUND RODS PLUMB (1) 4" SCH40 PVC 20' TO "P21" (CONDUIT FULL W/ 30 15kV 1/0 CU JACKETED CABLES) P14TOP17- - INSTALL - INSTALL P17 TO P18 - - INSTALL - INSTALL P18 TO P21 - - INSTALL - INSTALL SPECIFIC OH SPAN NOTES (3) #2ACSR PRIMARY CONDUCTOR APPROX. 125' (1) #2ACSR OH GROUND CONDUCTOR APPROX. 125' (3) #2ACSR PRIMARY CONDUCTOR APPROX. 300' (1) #2ACSR OH GROUND CONDUCTOR APPROX. 300' (Via P19, P20) (3) #2ACSR PRIMARY CONDUCTOR APPROX. 900' (1) #2ACSR OH GROUND CONDUCTOR APPROX. 900' SPECIFIC UG SPAN NOTES P20 TO VO4 - INSTALL INSTALL INSTALL INSTALL P21 TO V054 INSTALL INSTALL INSTALL INSTALL (1) 4" SCH40 PVC CONDUIT APPROX. 20' 30 15kV RATED 1/0 CU MV105 -EPR CABLES APPROX. 75' 600V INSULATED #2 CU THHW GROUND CONDUCTOR APPROX. 75' CABLE TAGS SP013, SP014, SP015 (1) 4" SCH40 PVC CONDUIT APPROX. 20' 30 15kV RATED 1/0 CU MV105 -EPR CABLES APPROX. 75' 600V INSULATED #2 CU THHW GROUND CONDUCTOR APPROX. 75' CABLE TAGS SP016, SP017, SP018 Q(1-,/11 C/) 2 0 cn 8 < Z o a W 0Ow 0 II O Z 0_ w Z cD Q W LL _ W QOM¢ w • O� iizo): Z w O FE `o • W N 2 0• o O a. 0 zj° �Qco Q �w AV■ REVIEWED FOR COMPLIANCE N A NC MAY 12 2011 City of Tukwila BUILDING DIVISION ELI I- 0 394 RECEIVED MAY 04 2011 PERMIT CENTER 60' 0' 60' SCALE 120' IN FEET A y� *. UANTA SERVICES COMPANY 1 +: 2224 104th Avenue East Suite 1 Edgewood, WA 98372 Office (253) 952 -2128 Fax (253) 952 -2140 13400009037 NSC Job Number: Clint Thayer Engineer. Clint Thayer Drafter. Barry Eronson Checked: Wayne Hagan Approved: rOE 1 \.,j, 30237 /4)1, 4 *4,0 NA1, . 2 !! u i 1// EXPIRES 11119/ ??O 11 Revisions No. Date Description Segale Properties Phase 11 Customer Owned Temporary OH & UG Medium Voltage 12.5kV 30 Line Extension From South 200th Street, South to just North of South 204th Street Workzone 1 Construction Notes Sheet 3 of 6 0426201 1.dwg o) 0 0 z w -c 0 0 N 0 s 0 0 (DI 0 U) 0 0 0 0 0 I.. I Ty- 0 `0 0) C L c w u0 (1) L O z 0 I') 0 s 0 CD Apr 29, 2011 @ vo 1 SECONDARY VOLTAGE - 480Y/277V DISCONNECT SIZE - 100 AMP @ V03 SECONDARY VOLTAGE - 480Y/277V DISCONNECT SIZE - 400 AMP 500kVA 12,470V 480Y/277V 1 A -Y SWO6 40T 40A (C12) FUSE 15A (C08) FUSE 112.5kVA 12,470V 480Y/277V A -Y SWO5 200A S.B. (3)1 POLE 1 THROW SW03 / / / I / / @ VO4 SECONDARY VOLTAGE - 480Y/277V DISCONNECT SIZE - 200 AMP DISCONNECT SIZE - 100 AMP @ V05 SECONDARY VOLTAGE - 480Y/277V DISCONNECT SIZE - 200 AMP DISCONNECT SIZE - 100 AMP 17,200A> 300kVA 12,470V 480Y/277V A -Y SW02 65T 25A (C10) FUSE 25A (C10) FUSE 300kVA 12,470V 480Y/277V A -Y 25A (C10) FUSE CUSTOMER OWNED AND OPERATED Swot 600A 30 3 POLE 1 THROW SW07 40T S W08 40T <PSE 200A, 12.5kV PRIMARY METER PUGET SOUND ENERGY Estimated Fault Current 0 to 0 - 7,500 Amps Estimated Fault Current 0 to Ground - 5,500 Amps SW04 40T 225kVA 12,470V 480Y/277V A -Y 112,600A> @ V02 SECONDARY VOLTAGE - 480Y/277V DISCONNECT SIZE - 200 AMP UNDERGROUND CABLE (1/0 CU MV105, EPR) OVERHEAD CONDUCTOR (#2 ACSR) 90° L WITH 5'R Pso OI SW07 40T (1) -4" SP013 SP014 SP015 300kVA 12,470V 480Y/277 A -Y 110.i; ONE LINE CONDUIT AND CABLE DIAGRAM NOT TO SCALE / AFTER CONSTRUCTION NOTE: • ALL CONDUIT TO BE UL LISTED SCHEDULE 40 OR BETTER, ELECTRICAL GRADE, GRAY • CONDUIT DEFLECTION SHALL HAVE A 5' MINIMUM BENDING RADIUS NOTES: `.:J 15kV CABLE 1/0 AWG COPPER, STRANDED / SHIELDED (COMPACTED) 220 MIL EPR MV -105 WITH 600V RATED COVERED GROUND CONDUCTOR, COPPER, STRANDED (COMPACTED), WITH THHW INSULATION IN THE SAME CONDUIT AS THE PRIMARY CABLE. Xxxxxi> AVAILABLE 30 FAULT CURRENT (AMPS) AT SECONDARY LUGS IN TRANSFORMER. THESE VALUES ARE BASED ON WORST CONDITION - ZERO LINE AND FAULT RESISTANCE WITH INFINITE BUSS ALL TRANSFORMERS ARE EQUIPPED WITH AN INTERNAL ISOLATION LINK IN SERIES WITH A REMOVABLE REPLACEABLE EXPULSION (BAY -O -NET) FUSE OVERHEAD & UNDERGROUND ONE -LINE CIRCUIT SCHEMATIC NOT TO SCALE / AFTER CONSTRUCTION e2D01 SW08 40T (1) -4" SP016 SP017 SP018 90° L WITH 5'R 300kVA 12,470V 480Y/277 L -Y ONE -LINE CONDUIT AND CABLE DIAGRAM NOT TO SCALE / AFTER CONSTRUCTION tL1lO39' SPXXX NOTE: 1. POLYETHYLENE CABLE IDENTIFICATION TAG HAS PHENOLIC 1/2" HIGH BLACK CHARACTERS ON A CONTRASTING BACKGROUND. 2. ATTACH CABLE TAG WITH NYLON CABLE TIES TO EACH END OF THE PRIMARY CABLE, ELBOW, STRAIGHT SPLICE OR TERMINATION. CABLE IDENTIFICATION TAG DETAIL NOT TO SCALE REVIEWED.FOR COMPLIANCE WITH NFPA 70 - NEC 18" Typical MAY 12 2011 City of Tukwila BUILDING DIVISION Final Grade 36" Min to 48" Max Cover Excavated Dirt Pile 24" Min -I 6" Sand Cover 4f 3" Sand Bedding 4" Sch40 PVC RECEIVED MAY 04 2011 PERMITCENTER PRIMARY TRENCH EXCAVATION DETAIL NOT TO SCALE G /NEERI NG IN A a UANTA SERVICES COMPANY 2224 104th Avenue East Suite 1 Edgewood, WA 98372 Office (253) 952 -2128 Fax (253) 952 -2140 13400009037 NSC Job Number: Clint Thayer Engineer, Clint Thayer Drafter. Barry Eronson Checked: Wayne Hagan Approved: ry) d� 0` �:4 30,.37 � ' r, + EXPIRES 11/19/ 2Q /j Revisions No. Date Description Segale Properties Phase 11 Customer Owned Temporary OH & UG Medium Voltage 12.5kV 30 Line Extension From South 200th Street, South to just North of South 204th Street Diagrams One -Line Circuit Schematic One -Line Conduit and Cable Diagrams Trench Excavation Detail Cable Tag Detail Sheet 4 of 6 11:29am I: \Shared \NorthSky \A5 Engineering Work \Working \134000090__ — Segale_OH South of 200th\ NEW_NSE Design 04262011.dwg Apr 29, 2011 TANGENT POLE DETAIL @ P19 & P20 / NOT TO SCALE c� DEAD END POLE DETAIL @ P14 & P21 / NOT TO SCALE NOTE: FRAME POLES PER LOCAL UTILITY STANDARDS FOR EASE OF FUTURE MAINTENANCE 6" Witatitaft TRANSFORMER CONCRETE PAD DETAIL @ VO4 AND V05 / NOT TO SCALE NOTE: Provide 8" minimum of 5/8 - compacted (100 %) crushed rock under pad for transformer support. DOUBLE DOUBLE DEAD -END POLE DETAIL @ P17 & P19 / NOT TO SCALE TRANSFORMER CASE # 2 CU. BARE SOLID (TYP) BOND TO TRANSFORMER CASE AND BOTH GROUND RODS (1) EA 8' LENGTH X 3/4" DIA CU. CLAD STEEL GROUND RODS PLACE (1) ROD INSIDE SECONDARY (TYP) TRANSFORMER PAD 36" Min 1 -4" PVC (TO TERM POLE) GROUND ROD INSTALLATION DETAIL @ VO4 & V05 FACING VAULT DOORS / NOT TO SCALE CUSTOMER SUPPLIED CONDUIT (TYPICAL) Install switchboard to be black plastic w /white labels. board dimensions = 24" high x 6" wide using 5" high lettering mount vertically and facing the road 12 ft min above ground TERMINATION POLE DETAIL AT P20 & P21 / NOT TO SCALE 30 TRANSFORMER CASE (VO4 & V05) PRIMARY CABLE DRAIN WIRES FROM CABLE SHIELDING GROUND PAD ON TRANSFORMER E PRIMARY SECONDARY '/C# 2 CU. COVERED GROUND IN PRIMARY CONDUIT PERMITCENTER NOTE: APPLY GREEN PHASE TAPE WHERE COVERED GROUND EXITS THE CONDUIT REVIEWED. FOR COMPLIANCE WITH NFPA 74 - NEC MAY 1 2 2011 City of Tukwila BUILDING DIVISION # 2 CU. SOFT DRAWN BARE CU. BUS (TYP) 8' LENGTH X 3/4" DIA GROUND ROD (INSIDE TRANSFORMER DOORS IN CABLE ACCESS AREA) (TYP) RECEIVED MAY 04 2011 GROUNDING / BONDING SCHEMATIC @ VO4 & V05 / NOT TO SCALE A) UANTA SERVICES COMPANY 2224 104th Avenue East Suite 1 Edgewood, WA 98372 Office (253) 952 -2128 Fax (253) 952 -2140 13400009037 NSC Job Number: Clint Thayer Engineer. Clint Thayer Drafter. Barry Eronson Checked: Wayne Hagan Approved: 3023? 44) \.<!;/-, STS . -'ceA ;1V l tr y %2q%l' it J EXPIRES 11/19/ ?-011 Revisions No. Date Description Segale Properties Phase II Customer Owned Temporary OH & UG Medium Voltage 12.5kV 30 Line Extension From South 200th Street, South to just North of South 204th Street Pole Details Tangent Dead -End Termination Transformer Details Sheet 5 of 6 11:30am I: \Shared \NorthSky \A5 Engineering Work \Working \134000090__ — Segale_OH South of 200th\ NEW_NSE Design 04262011.dwg Apr 29, 2011 STRINGING SAG TABLE (P14 -P17) Stringing Sag Table Using initial Sag Ruling Span: 125.0 Feet Conductor SPARROW # 2 AWG 6/ 1 Stranding ACSR NESC Medium Load Zone Max Tension = 840 Lb Design: 840. Lb @ 15. Deg F, .25 In Ice, 4.00 Psf Wind, Initial H Tens 542. 513. 484. 455. 426. 397. 368. 340. 312. 285. 260. (LBS) Temp F> 40. 45. 50. 55. 60. 65. 70. 75. 80. 85. 90. Sag Feet Feet Feet Feet Feet Feet Feet Feet Feet Feet Feet Span 90.0 .17 .18 .19 .20 .22 .23 .25 .27 .30 .32 .35 100.0 .21 .22 .23 .25 .27 .29 .31 .33 .36 .40 .44 110.0 .25 .27 .28 .30 .32 .35 .37 .40 .44 .48 .53 120.0 .30 .32 .34 .36 .38 .41 .44 .48 .52 .57 .63 130.0 .35 .37 .40 .42 .45 .48 .52 .57 .62 .67 .74 140.0 .41 .43 .46 .49 .52 .56 .61 .66 .71 .78 .86 150.0 .47 .50 .53 .56 .60 .64 .69 .75 .82 .90 .98 160.0 .54 .57 .60 .64 .68 .73 .79 .86 .93 1.02 1.12 STRINGING SAG TABLE (P17 -P18) Stringing Sag Table Using Initial Sag Ruling Span: 300.0 Feet Conductor SPARROW # 2 AWG 6/ 1 Stranding ACSR NESC Medium Load Zone Max Tension = 840 Lb Design: 840. Lb @ 15. Deg F, .25 In Ice, 4.00 Psf Wind, initial H Tens 185. 180. 176. 172. 168. 165. 161. 158. 155. 152. 149. (LBS) Temp F> 40. 45. 50. 55. 60. 65. 70. 75. 80. 85. 90. Sag Feet Feet Feet Feet Feet Feet Feet Feet Feet Feet Feet Span 260.0 4.17 4.27 4.37 4.48 4.58 4.68 4.77 4.87 4.97 5.06 5.15 270.0 4.49 4.61 4.72 4.83 4.94 5.04 5.15 5.25 5.35 5.46 5.56 280.0 4.83 4.95 5.07 5.19 5.31 5.42 5.54 5.65 5.76 5.87 5.97 290.0 5.18 5.31 5.44 5.57 5.69 5.82 5.94 6.06 6.18 6.29 6.41 300.0 5.55 5.69 5.82 5.96 6.09 6.23 6.36 6.48 6.61 6.74 6.86 310.0 5.92 6.07 6.22 6.36 6.51 6.65 6.79 6.92 7.06 7.19 7.32 320.0 6.31 6.47 6.63 6.78 6.93 7.08 7.23 7.38 7.52 7.66 7.81 330.0 6.71 6.88 7.05 7.21 7.37 7.53 7.69 7.85 8.00 8.15 8.30 340.0 7.13 7.31 7.48 7.66 7.83 8.00 8.17 8.33 8.49 8.65 8.81 STRINGING SAG TABLE (P18 -P21) Stringing Sag Table Using Initial Sag Ruling Span: 300.0 Feet Conductor SPARROW # 2 AWG 6/ 1 Stranding ACSR NESC Medium Load Zone Max Tension = 840 Lb Design: 840. Lb @ 15. Deg F, .25 In Ice, 4.00 Psf Wind, Initial H Tens 185. 180. 176. 172. 168. 165. 161. 158 155. 152. 149. (LBS) Temp F> 40. 45. 50. 55. 60. 65. 70. 75. 80. 85. 90. Sag Feet Feet Feet Feet Feet Feet Feet Feet Feet Feet Feet Span 260.0 4.17 4.27 4.37 4.48 4.58 4.68 4.77 4.87 4.97 5.06 5.15 270.0 4.49 4.61 4.72 4.83 4.94 5.04 5.15 5.25 5.35 5.46 5.56 280.0 4.83 4.95 5.07 5.19 5.31 5.42 5.54 5.65 5.76 5.87 5.97 290.0 5.18 5.31 5.44 5.57 5.69 5.82 5.94 6.06 6.18 6.29 6.41 300.0 5.55, 5.69 5.82 5.96 6.09 6.23 6.36 6.48 6.61 6.74 6.86 310.0 5.92 6.07 6.22 6.36 6.51 6.65 6.79 6.92 7.06 7.19 7.32 320.0 6.31 6.47 6.63 6.78 6.93 7.08 7.23 7.38 7.52 7.66 7.81 330.0 6.71 6.88 7.05 7.21 7.37 7.53 7.69 7.85 8.00 8.15 8.30 340.0 7.13 7.31 7.48 7.66 7.83 8.00 8.17 8.33 8.49 8.65 8.81 TECHNICAL TRANSFORMER SCHEDULE Site Manufacturing Serial Number kVA Phase Type Coding / 9 Class HZ 30 Primary ' Voltage 30 Secondary '' Voltage Windings Fusin Transformer High Voltage Feed Tiru Bushings Internal High Voltage Switch % Impedance Tap Changer High Voltage BIL kV Low Voltage BIL kV Degree "C" Rise PCB Remarks VO4 1/0 CU MV105 -EPR 75 300 30 Padmount (Dead - Front) Oil 1 OA 60 12470 480Y/277V ,61,-Y Internal Bayonet No Yes Min 2.10% - 5.0% Max Yes - In the Primary Compartment 95 30 ' 65 Less than 1 PPM 30 Tangent Line Pole (Less than 3 °) 30 Primary Termination Install 18" Switchboard - SW07 (To "VO4 ") V05 P21 60 300 30 Padmount (Dead- Front) Oil 1 OA 60 12470 480Y/277V p Y Internal Bayonet No Yes Min 2.10% - 5.0% Max Yes - In the Primary Compartment 95 30 65 Less than 1 PPM VAULT AND APPARATUS SCHEDULE Site Vault Size Vault Cover Size Type & Size of Apparatus Additional Material Needed Comments VO4 - 5'- 6` "X4' -8 "x6" Transformer Pad with 44'5f20" Access Hole 300kVA 30 PM Xfmr 12.47kV - 480Y/277 (3) 200A 15kV Rated Load Break Elbow from V05 - 5'- 6 " "X4' -8 "x6" Transformer Pad with 44 "x20" Access Hole 300kVA 30 PM Xfmr 12.47kV - 480Y/277 (3) 200A 15kV Rated Load Break Elbow VO4 MEDIUM VOLTAGE CONDUIT AND CABLE SCHEDULE Location CONDUIT PRIMARY CABLE (15kV Rated) Remarks Size (in) Qty Typ Length _ (.0) Cable Size and Type Length (ft) Cable Numbers from to A B C P20 VO4 4 1 Sch40 PVC 20 1/0 CU MV105 -EPR 75 SP013 SP014 SP015 30 Full Tension Double DE 3/8" Primary Down Guys (L =15') P21 V05 4 1 Sch4O PVC 20 110 CU MV105 -EPR 75 SP016 SP017 SPO18 - NOTE: THE GROUND CONDUCTOR SHALL BE 600V RATED CABLE, COPPER, CLASS B STRANDED (COMPACTED), WITH POLYETHYLENE COMPOUND OUTER JACKET (THHW) IN THE SAME CONDUIT AS THE PRIMARY CABLE. POLE SCHEDULE Site Pole Framing Remarks Height Class Year Type P14 45 3 - Wood 30 Full Tension DE 3/8" Primary Down Guy (L =15) See Dead -end Pole Detail P17 60 3 - Wood 30 Full Tension Double DE 3/8" Primary Down Guys (L =15') See Double- Double Dead -end Pole Detail P18 60 3 - Wood 30 Full Tension Double DE 3/8" Primary Down Guys (L =15') See Double - Double Dead -end Pole Detail P19 60 3 - Wood 30 Tangent Line Pole (Less than 3 °) See Tangent Pole Detail P20 60 3 - Wood 30 Tangent Line Pole (Less than 3 °) 30 Primary Termination Install 18" Switchboard - SW07 (To "VO4 ") See Tangent Pole & Termination Details P21 60 3 - Wood 30 Full Tension DE 3/8" Primary Down Guys (L =15') 30 Primary Termination Install 18" Switchboard - SWO8 (To "V05 ") See Dead -End Pole & Termination Detail NOTE: FOR DETAILED FRAMING INSTRUCTIONS SEE SPECIFIC CONSTRUCTION NOTES ON RELATED WORKZONES OVERHEAD WIRE INSTALLATION SCHEDULE Span Wire Size Type Number of Phases Footage (ft) Footage (ft) Actual Remarks P14 to P17 (3) - #2 ACSR 30 125 Primary (1) - #2 ACSR Ground P17 to P18 (3) -#2 ACSR 30 300 Primary (1) - #2 ACSR Ground P18 to P21 (3) - #2 ACSR 30 900 Primary (1) - #2 ACSR Ground REVIEWED FOR COMPLIANCE WITH NFPA70 -NEC MAY 12 2011 City of Tukwila BUILDING DIVISION RECEIVED MAY 042011 PERMIT CENTER LtlO3'L1 A t''� UANTA SERVICES COMPANY 2224 104th Avenue East Suite 1 Edgewood, WA 98372 Office (253) 952 -2128 Fax (253) 952 -2140 13400009037 NSC Job Number: Clint Thayer Engineer. Clint Thayer Drafter. Barry Eronson Checked: Wayne Hagan Approved: A. �w4 ,p 3023? EXPIRES 11/19/ O/I Revisions No. Date Description Segale Properties Phase 11 Customer Owned Temporary OH & UG Medium Voltage 12.5kV 30 Line Extension From South 200th Street, South to just North of South 204th Street Schedules Technical Stringing and Sag Sheet 6 of 6