Loading...
HomeMy WebLinkAboutPermit EL11-0523 - WESTFIELD SOUTHCENTER MALL - PAC SUNThis record contains information which is exempt from public disclosure pursuant to the Washington State Public Records Act, Chapter 42.56 RCW as identified on the Digital Records Exemption Log shown below. El-1 1-0523 Pac Sun 650 Southcenter Mall RECORDS DIGITAL D- ) EXEMPTION LOG THE ABOVE MENTIONED PERMIT FILE INCLUDES THE FOLLOWING REDACTED INFORMATION Page # tode Exemption = 8rlef Explanatory DeSclriptiop �t�tutel ule The Privacy Act of 1974 evinces Congress' intent that social security numbers are a private concern. As such, individuals' social security Personal Information — numbers are redacted to protect those Social Security Numbers individuals' privacy pursuant to 5 U.S.C. sec. 5 U.S.C. sec. DR1 Generally — 5 U.S.C. sec. 552(a), and are also exempt from disclosure 552(a); RCW 552(a); RCW under section 42.56.070(1) of the Washington 42.56.070(1) 42.56.070(1) State Public Records Act, which exempts under the PRA records or information exempt or prohibited from disclosure under any other statute. Redactions contain Credit card numbers, debit card numbers, electronic check numbers, credit Personal Information — expiration dates, or bank or other financial RCW 23 DR2 Financial Information — account numbers, which are exempt from 42.56.230(5) RCW 42.56.230(4 5) disclosure pursuant to RCW 42.56.230(5), except when disclosure is expressly required by or governed by other law. PAC SUN 650 SOUTHCENTER MALL EL1 1 -0523 City oilkukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov Parcel No.: 9202470010 Address: 650 SOUTHCENTER MALL TUKW Project Name: PAC SUN ELECTRICAL PERMIT Permit Number: EL11 -0523 Issue Date: 09/16/2011 Permit Expires On: 03/14/2012 Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA Contact Person: Name: AMY DIEKEVERS Address: 75 60 ST SW , WYOMING MI Contractor: Name: RED CEDAR ELECTRICAL CONSTRUCTION LLC Address: PO BOX 14294 , BOTHELL WA Contractor License No: REDCECE934C 1 Phone: 616- 493 -9334 Phone: 425 - 315 -5075 Expiration Date: 02/21/2013 DESCRIPTION OF WORK: TENANT IMPROVEMENT WITH REVISION OF ELECTRICAL LIGHTING AND POWER. UPGRADE OF ELECTRICAL PANELS Value of Electrical: NRES: $21,839.00 Fees Collected: $651.62 RES: $0.00 Type of Fire Protection: UNKNOWN Electrical service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: National Electrical Code Edition: 2008 Date: q-4/(19-- I I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the perform nce of work. I am authorized to sign and obtain this electrical permit. Signature: Print Name: Ji�y 4Qd ,4c Date: 9 /r0% This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/10 EL 11 -0523 Printed: 09 -16 -2011 • PERMIT CONDITIONS Permit No. EL11 -0523 * *ELECTRICAL ** 1: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 2: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 3: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 4: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 5: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 6: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. doc: EL -4/10 EL11 -0523 Printed: 09 -16 -2011 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://wwwci.lukwilawa.us Electrical Permit No. a--11-05 oZ-3 Project No. (For of ce use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** l L J King Co Assessor's Tax No.:(��� 3 6 L' t 0 Site Address: 6 5a J01)-1A Suite Number: Floor: Tenant Name: Gf C U Ai New Tenant: ....Yes ❑ ..No Property Owners Name: Mailing Address: ,• vv0 It') A C.eM 7 1/4,. City State Zip CONTACT PERSON - Who do we contact when your permit is ready to be issued Name: Mailing Address: 751 60 L-..2". (✓ (.0 y riA 1 City E-Mail Address: (� t pre C-1 '`-?I d f.Q1'/1t I T -`mot CdMax Number: /4rky Vim -c_k eft Day Telephone: (04, c/( ELECTRICAL CONTRACTOR INFORMATION Company Name: Mailing Address: State Zip q77 q ?�±-7/ City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Project (contractor's bid price): $ 22, E.`'`� )7 Scope of Work (please provide detailed information): upgrade of electrical panels Tenant improvement with revision of electrical lighting and power, Will service be altered? ❑ Yes ® No Type of Use: Type of work: ❑ New Commercial Tenant Improvement (Mercantile) Adding more than 50 amps? ❑ Yes ® No ❑ Addition ❑ Low Voltage ❑ Generator Property Served by: ® Puget Sound Energy ❑ Seattle City Light ❑ Service Change ® Fire Alarm H. \ Applications \Forms-Applications On Line \1 -2009 - Electrical Permit Application.doc bh ® Remodel ® Tenant Improvement ® Telecommunication ❑ Temporary Service Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $145.60 (including an attached garage) ❑ Garages, pools, spas and outbuildings $78.00 ea ❑ Low voltage systems (alarm, furnace thermostat) $57.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $78.00 (no added/altered circuits) ❑ Service change with added/altered circuits $78.00 number of added circuits $11.00 ea ❑ Circuits added/altered without service change $52.00 (up to 5 circuits) ❑ Circuits added/altered without service change $52.00 (6 or more circuits) $7.30 ea ❑ Meter /mast repair $65.00 ❑ Low voltage systems $57.00 (alarm, furnace thermostat) MULTI - FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $60.00 ❑ Temporary service (generator) $75.00 ❑ Manufactured/mobile home service $80.00 (excluding garage or outbuilding) ❑ Carnivals $75.00 Number of concessions $10.00 ea PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECT CAL CONTRACTOR: Signature: Print Name: PPS Day Telephone: Date: SG3 3q7 Mailing Address: Date Application Accepted: (. r Date Application Expires: City ceo State Staff Initials: Zip H:Wppli cat ions \Forms - Appli cation s On Line \I -2009 - Electrical Permit Application. doc bh Ur Page 2 of 2 1 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov RECEIPT Parcel No.: 9202470010 Permit Number: EL11 -0523 Address: 650 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 06/08/2011 Applicant: PAC SUN Issue Date: Receipt No.: R11 -02031 Initials: WER User ID: 1655 Payment Amount: $529.59 Payment Date: 09/16/2011 10:27 AM Balance: $0.00 Payee: RED CEDAR ELECTRICAL CONSTRUCTION TRANSACTION LIST: Type Method Descriptio Amount Payment Check 5686 529.59 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.00 529.59 Total: $529.59 doc: Receiot -06 Printed: 09 -16 -2011 CAP of Tukwila. • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: //www. ci. tukwila. wa. us SET RECEIPT RECEIPT NO: R11 -01163 Initials: WER Payment Date: 06/08/2011 User ID: 1655 Total Payment: 1,735.76 Payee: PRECISION PERMIT SERVICE SET ID: 6 -8 -11 SET NAME: PAC SUN SET TRANSACTIONS: Set Member Amount D11 -161 EL11 -0523 M11 -075 PG11 -079 TOTAL: 1,482.26 122.03 66.11 65.36 1,482.26 TRANSACTION LIST: Type Method Description Amount Payment Check 8036 1,735.76 TOTAL: 1,735.76 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES 000.345.832.00.0 PLAN CHECK - NONRES 000.345.830 TOTAL: 122.03 1,613.73 1,735.76 AGREEMENT BEEN CONTRACTOR AND SUBCON'1OCTOR This Agreement, made this 19 day of Sugust CONTRACTOR: and the Hardesty & Associates, Inc. 500 E. Balboa Blvd. Newport Beach, CA 92661 Contractors License No. HARDEA1066PP I. For the following PROJECT: II. PacSun 20 11 , between the SUBCONTRACTOR: Red Cedar Electcrical Construction, LLC PO Box 14294 Mill Creek, WA 98082 Subcontractors License No. Subcontractor's Project Contact: Jay Cabuag Subcontractor's Contact Phone: 425- 315 -5075 Subcontractor agrees to furnish all permits, labor, services, materials, installation, cartage, hoisting, supplies, insurance, equipment, scaffolding, tools, removal of their own trash and debris, and facilities of every kind and description required for the prompt, efficient execution of the following work: Electrical III. WORK Including but not limited to: Project Scope Attached hereto as Exhibit "B" IV. And as further described in the CONTRACT DOCUMENTS: Plans and specifications dated 24-May prepared by Fitch Exhibits and Addenda described as Through Delta 5 dated 8 -10 -11 Subcontractor's bid attached hereto, and Contractor's Progress Schedule attached hereto as Exhibit "A ". v. VI. PRICE OF: Twenty-One Thousand Eight Hundred Thirty-Nine & 00/100 ($21,839.00) INSURANCE: Subcontractor shall furnish Certificates of Insurance to Contractor upon execution of the Subcontract evidencing the following coverage: (1) the General Liability Certificates must be written by an insurance company with at least an "A -" IX rating in the most recent addition of Best's Insurance Reports, and has limits of $1,000,000, per Occurrence, $2,000,000 General Aggregate, and $2,000,000 Products - Completed Operations Aggregate. Hardesty & Associates, Inc. must be listed as certificate holder, and listed as additional insured. The project name and location must be on the certificate. The policy must be an "Occurrence" form and not a "Claims Made" form. Subcontractor shall maintain such insurance, naming Contractor as an additional insured, for a period of ten years from substantial completion of the project; provided however, that if the law of the State in which the work is performed provides for a longer statute of limitations for actions based upon latent defects, Subcontractor shall maintain such insurance, naming Contractor an an additional insured, for the longer period. Subcontractor shall provide Contractor annually with certificates of such continued insurance. (2) Automobile Insurance Coverage with limits no less than $1,000,000. (3) Evidence of Worker's Compensation Insurance. VII. PAYMENT SCHEDULE: Subcontractor shall submit payment applications reflecting Subcontractor's completion of work covered by the application. A condition precedent to Contractor's obligation to make payment under the Subcontract shall be receipt by Contractor of payment from the Owner which covers the work subject of Subcontractor's submitted payment applications. In the event, Owner fails to make such payment, Subcontractor's legal mechanic's lien and stop notice rights against Owner or the Construction Lender are preserved, but Contractor shall have no Page 1 of 4 pages - Please initial Contractor Subcontractor RECEIVED SEP 16 2011 PERMIT CENTER INSP'CTION NO. INSPECTION RECORD Retain a copy with permit Eu� -osz3 PERMIT NO. 'CITY OFTUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 - Permit Inspection Request Line (206) 431 -2451 1 t .. Project: 5»J Type of Inspection: 2.00 Address: 0 n Date Called: Special Instructions: • - Date Wanted:. I 1108 J a m. Requester: ((( Phone No: E( Approved per applicable codes. ElCorrections required prior to approval. COMMENTS: 6)04q-kot45 wi)c - - . , 114Nt..1 Inspector: Date: /1/08/1/ REINSPECTION.!EE REQUIRED. Prior to next inspection. fee must be paid at 6300.Southcenter Blvd.. Suite 100. Call to schedule reinspection. • 5 INSPECTION RECORD 6)o523 Retain a copy with permit INSPECTION NO. P RMIT NO. /0b CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -36 Permit Inspection Request Line (206) 431 -2451 Project: AL S>,4 Type of Inspection: oVnl kAl - IS44146s. 4U 1165 M iNih,Tl al Address: �jb iInk/ Date Called: . tAisrikti ✓ MksetiOAs, tolJOGE ei,04 Fob,. . d.ir I4(,i Muir Special Instructions: • Date Wanted:. . , 0 /3' /0 a Requester: Phone No: . Approved per applicable codes. ® Corrections required prior to approval. COMMENTS: ■ C i fe-i'reql 0/ R( y' * Co t,JA oVnl kAl - IS44146s. 4U 1165 M iNih,Tl al C4Rc.J1 T . tAisrikti ✓ MksetiOAs, tolJOGE ei,04 Fob,. . d.ir I4(,i Muir - Ca P 4 OF 0444-0i Inspector: "` • . . ,is REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: 10#1/I era INSPECTION NO. INSPECTION RECORD Retain a copy with permit 41 Eul -�sz3 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION • 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection. Request Line (206) 431 -2451 (206) 431 -36 Project: jj AC Type of Inspection: 70»,) Address: / �� � Date Called: Special Instructions: • Date Wanted:. /0/2-Y 1m. (per Requester: Phone No: IDApproved per applicable codes. ElCorrections required prior to approval. COMMENTS: . Otzt914( Inspector: (Date: /oi21 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid of 6300•Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD ) Retain a copy with permit INSPECTION NO. PERMIT NO. • CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 431 -2451 Project: (206) 431 -367 4 Type of Inspection: 7003 Address: Special Instructions: • El Approved pet applicable codes. Date Called: Date Wanted: . Requester: /9/07 Phone No: ECorrections required prior to approval. COMMENTS: Inspector: Date: it)/C0 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. L. INSPECTION RECORD �, I t-D��� Retain a copy with permit [.! INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 0. (206) 431 -36 Permit Inspection Request Line (206) 431 -2451 Project: At_ SA1 Type of Inspection: 7203 Address: Special Instructions: Date Called: Date Wanted: . Requester: /6/03 Phone No: Approved per applicable codes. a Corrections required prior to approval. COMMENTS: iaiAIAJ) M)L-, t)S 6mQ.c aJr 1 Inspector: Date: /0/0 3/, CI\ ri REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF' TUKWILA BUILDING DIVISION /\ 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -367 Permit Inspection Request Line (206) 431 -2451 E Project: p Type of Inspection: �D oi Address: ? IlAl/L, Date Called: Special Instructions: • • • Date Wanted:. ii7 pa, Requester: Phone No: Approved per applicable codes. D Corrections required prior to approval. OMMENTS: 04(.- OrsID SLA5 64‘)(13 Inspector: C416'\ REINSPECTIO FEE REQUIRED. Prior to next inspection, fee must be paid at 6300.Southcenter Blvd., Suite 100. Call to schedule reinspection. jDate: oi/,if(r q 2009 Washington State Energy Code Compliance Form for Nonresidential an Multifamily Residential Project Summary PRJ -SUM 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised December 2010 Project Info Project Address SOUTHCENTER SHOPPIN MALL Date 8/11/2011 SPACE #208 For Building Department Use TUKWILA, WASHINGTON Applicant Name: Applicant Address: Applicant Phone: PELF COPY Pere' Pt No. REVISION N0:1 EL11- •�513 REVIEWED FOR COMPLIANCE WITH NFPA 70 m NEC .:;1 12011 City of Tukwila BUILDING DIVISION RECEIVED AUG 25 2011 PERMITCENTER 2009 Washington State Energy Code Compliance Form for Nonresidential a Multifamily Residential • Interior Lighting Summary LTG -INT 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised December 2010 Project Info Project Address SOUTHCENTER SHOPPIN MALL Date 8/15/2011 SPACE 6208 For Building Department Use TUKWILA, WASHINGTON Applicant Name: Applicant Address: Applicant Phone: 4285 Project Description • New Building • Addition n Alteration • Plans Included Refer to WSEC Section 1513 for controls and commissioning requirements. Compliance Option e Prescriptive 0 Lighting Power Allowance (See Qualification Checklist (over). Indicate Prescriptive & LPA 0 Systems Analysis spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) not changed • No changes are being made to the lighting and space use ■ Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Maximum Allowed Lighting Wattage Location (floor plan /room #) Occupancy Description Allowed Watts per Gross Interior Area in ft2 Allowed x Area SALES AREA RETAIL 1.33 3222 4285 BACK AREA OFFICE /STORAGE 0.91 543 494 BACK AREA CORRIDOR /TOILET 0.80 307 246 SALES AREA MERCHANDISE DISPLAY 1.40 1960 2744 " From Table 15 -1 (over) - document all exceptions on form LTG -LPA Proposed Lighting Wattage Total Allowed Watt 7769 Location (floor plan /room #) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed SALES C1 - LINE VOLTAGE TRACK LIGHT (1 -10W LED LAMP) 75 10 750 FITTING ROOMS D - 6" RECESSED DOWNLIGHT (1 -60W PAR LAMP) 18 60 1080 FITTING ROOMS G1 - 2FT STRIP FLUORESCENT (1 -17W T8 LAMP) 14 22 308 FITTING ROOMS G2 - 3FT STRIP FLUORESCENT (1 -25W T8 LAMP) 26 27 702 OFFICE /STORAGE /T OILETS ROOMS U - STRIP FLUORESCENT (1 -32W T8 LAMP) 61 32 1952 STOREFRONT C1 - LINE VOLTAGE TRACK LIGHT (1 -10W LED LAMP) TAB.15 -1 NOTE 10 SALES / STOREFRONT TOTAL TRACK LENGTH = 557FT. (USE CURRENT LIMITER SUB- PANEL) Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed W 4792 Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts/Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For line voltage track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. For low voltage track lighting list the transformer rated wattage. 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts /Fixture blank. 2009 Washington State Energy Code Compliance Form for Nonresidential and Multifamily Residential Interior Lighting Summary (back)I, LTG -INT 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised December 2010 Prescriptive Spaces Occupancy: 0 Warehouse or Parking Garage • Other Qualification Checklist Note: If occupancy type is "Other" and fixture answer is checked, the number of fixtures in the space is not limited by Code. Clearly indicate these spaces on plans. If not qualified, do LPA Calculations. Lighting Fixtures: (Section 1521) 0.85 • Check if 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted. 1. Fluorescent fixtures with a) 1 or 2 two lamps, b) reflector or louve c) 5 -60 watt T -1, T -2, T-4, T -5, T -8, or CFL lamps, and d) hard -wired electronic dimming ballasts. Screw -in CFL fixtures and tracking lighting do not qualify. 2. Metal Halide with a) reflector b) ceramic MH lamps < =150w c) electronic ballast 3. LED lights. TABLE 15 -1 Unit Liahtina Power Allowance (LPA Use' LPA` (W /ft`) Use' LPA' (W /ft`) Automotive facility 0.85 Office buildings, office /administrative areas in facilities of other use types (including but not limited to schools, hospitals, institutions, museums, banks, churches)5 0.91 Convention center 1.10 Parking garages 0.20 Courthouse 1.10 Penitentiary and other Group 1 73 Occupancies 0.90 Cafeterias, fast food establishments', restaurants /bars5 1.20 Police and fire stations 0.90 Dormitory 0.85 Post office 1.00 Dweling Units 1.00 Retail"', retail banking, mall concourses, wholesale stores (pallet rack shelving) 1.33 Exercise center 0.95 School buildings (Group E Occupancy only), school classrooms, day care centers 1.00 Gymnasia, assembly spaces 0.95 Theater, motion picture 0.97 Health care clinic 1.00 Theater, performing arts 1.25 Hospital, nursing homes, and other Group 1 -1 and 1 -2 Occupancies 1.20 Transportation 0.80 Hotel /motel 1.00 Warehouses 0.50 Laboratory spaces (all spaces not classified "laboratory" shall meet office and other appropriate categories) , 1.62 Workshops 1.20 Laundries 1.20 Libraries' 1.20 Plans Submitted for Common Areas Only' Manufacturing facility 1.20 Main floor building lobbies3 (except mall concourses) 1.10 Museum 1.00 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.80 Footnotes for Table 15 -1 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by 2% per foot of ceiling height above 20 feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by 2% per foot of ceiling height above 12 feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by 2% per foot of ceiling height above 9 feet. 6) Reserved. 7) For conference rooms and offices less than 150ft2 with full height partitions, a Unit Lighting Power Allowance of 1.1 w/ft2 may be used. 8) Reserved. 9) For indoor sport tournament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is 2.60 W /ft2. 10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three - quarter- height partitions (transparent or opaque) and lighting for free - standing display where the lighting moves with the display are exempt. An additional lighting power allowance is allowed for merchandise display luminaires installed in retail sales areas that are specifically designed and directed to highlight merchandise. The following additional wattages apply: i. 0.6 watts per square foot of sales floor area not listed in items ii and iii below; ii. 1.4 watts per square foot of furniture, clothing, cosmetics or artwork floor area; or iii. 2.5 watts per square foot of jewelry, crystal or china floor area. The specified floor area for items i, ii, or iii above, and the adjoining circulation paths shall be identified and specified on building plans. Calculate the additional power allowance by multiplying the above LPDs by the sales floor area for each department excluding major circulation paths. The total additional lighting power allowance is the sum of allowances for sales categories!, ii, or iii plus an additional 1,000 watts for each separate tenant larger than 250 square feet in area. The additional wattage is allowed only if the merchandise display luminaires comply with all of the following: (a) Located on ceiling- mounted track or directly on or recessed into the ceiling itself (not on the wall). (b) Adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). This additional lighting power is allowed only if the lighting is actually installed and automatically controlled, separately from the general lighting, to be tumed off during nonbusiness hours. This additional power shall be used only for the specified luminaires and shall not be used for any other purpose. This additional lighting power is allowed only if the lighting is actually installed. 11) Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks. • • 2009 Washington State Energy Code Compliance Form for Nonresidential and Multifamily Residential Lighting, 2009 Washington Motor, and Transformer Permit Plans Checklist LTG -CHK State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised December 2010 Project Address SOUTHCENTER SHOPPIN MALL IDate 8/11/2011 The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements in the 2009 Washington State Nonresidential Energy Code. Applicability (yes, no, n.a.) Code Section Component Information Requires Location on Plans Building Department Notes LIGHTING CONTROLS (Section 1513) Yes 1513.1 Local control /access Schedule with type, indicate locations E200 Yes 1513.2 Area controls Maximum limit per switch E200 N.A. 1513.3 Daylight zone control Schedule with type and features, indicate locations N.A. vertical glazing Indicate vertical glazing on plans N.A. overhead glazing Indicate overhead glazing on plans N.A. 1513.4 Display /exhib /special Indicate separate controls N.A. 1513.5 Exterior shut -off Schedule with type and features, indicate location Yes (a) timer w /backup Indicate location E100 N.A. (b) photocell. Indicate location Yes 1513.6 Inter. auto shut -off Indicate location Yes 1513.6.1 (a) occup. sensors Schedule with type and locations E200 N.A. 1513.6.2 (b) auto. switches Schedule with type and features (back -up, override capability Indicate size of zone on plans ; E200 /E 300 N.A. 1513.7 Hotel /motel controls Indicate location of room master controls N.A. 1513.8 Commissioning Indicate requirements for lighting controls commissioning EXIT SIGNS (Section 1514) Yes 1514 IMax. watts 'Indicate watts for each exit sign IE3o0 I LIGHTING POWER ALLOWANCE (Section 1530 -1532) Yes 1531 Interior Lighting Summary Form Completed and attached. Schedule with fixture type lamps, ballasts, watts per fixture N.A. 1532 Exterior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture MOTORS (Section 1511) N.A. I 1511 IElec motor efficiency IMECH-MOT or Equipment Schedule with hp, rpm, efficiency I I TRANSFORMERS (Section 1540) N.A. I 1540 (Transformers IIndicate size and efficiency 1 I If "no" is circled for any question, provide explanation: • • a .l PLAN REVIEW /ROUTING SLIP Sa" ACTIVITY NUMBER: EL11 -0523 DATE: 08 -25 -11 PROJECT NAME: PAC SUN SITE ADDRESS: 650 SOUTHCENTER MALL Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # X Revision # 1 After Permit Issued DEPART ENTS I gul ding ivision Public Works n Fire Prevention Structural Planning Division ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete n DUE DATE: 08-30-11 Not Applicable n Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved Approved with Conditions DUE DATE: 09-27 -11 Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 • • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL11 -0523 DATE: 06 -08 -11 PROJECT NAME: PAC SUN SITE ADDRESS: 650 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # _ Revision # After Permit Issued DEPARTMENTS: adinfton Public Works Fire Prevention Structural Planning Division ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete n DUE DATE: 06 -14 -11 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: REVIEWER'S INITIALS: DATE: DUE DATE: 07-12-11 Not Approved (attach comments) n Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Web site: http: / /www.ci.tukwila.wa.us REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: Plan Check/Permit Number: E >< 11 OS-Q-3 ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: -Pea_ SUr\ Project Address: Contact Person: AIM I '"bltjLp 4 Pr S Phone Number: (QUO - L q;& gAil Summary of Revision: VOANRA Sr 9c\47 riaPS 4 l� & Co�Cu \o.ii (mS 0 c1c cc). der- (IA' l �� k4 ►nqq � � J azataitat orterfrumu AUG 252011 PERMIT CENTER Sheet Number(s): t . XCO E ?,op "Cloud" or highlight all areas of revision including date o revisio Received at the City of Tukwila Permit Center by: 0/5' Entered in Permits Plus on H:\Applicatims\Forms- Applications On Line\2010 Applicatims\7 -2010 - Revision Submitlal.doc Created 8-13 -2004 Revised: 7 -2010 Contractors or Tradespeople Per Friendly Page • Electrical Contractor A business licensed by LEti to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company RED CEDAR ELECTRICAL CONST LLC 4253571807 Po Box 14294 Mill Creek WA 98082 Snohomish Limited Liability Company UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 602693686 Active REDCECE934C1 Electrical Contractor 2/21/2007 2/21/2013 General Unused Master Electrician INFORMATION License CABUAJK975P2 Name CABUAG, JACOB K M JR Status Active Business Owner Information Name Role Effective Date Expiration Date CABUAG, KANANI Partner /Member 02/21/2007 Bond Information No records found for the previous 6 year period Assignment of Savings Information Page 1 of 1 Savings Assignment of Savings Account Number Effective Date Release Date Assignment Type Impaired Date Amount Received Date 1 2/20/2007 Until Released Bond $4,000.00 2/21/2007 Insurance Information No records found for the previous 6 year period Summons /Complaint Information Summons and Complaints are not filed with the department for this contractor type Warrant Information Warrants are not filed with the department for this contractor type https: // fortress .wa.gov /lni/bbip /Print.aspx 09/16/2011 L -20 L -3q (TIE -IN) L -18 ELECTRICAL POWER PLAN • DI DI ... 11- :,:,<,:_::: I i III • P. SEE CASHIA1RAP POWER DETAILS ON SWEET E101 L -22 • ►D L -10,12 • SEPARATE PERMIT REQUIRED FOR: LS Mechanical Elgiectrical DI Plumbing Cilo as Piping City of Tukwila BRIG DIVISION Penult No. F-1- i� -os23 Plan review approval is Ito effors and missions. Approval of consbuclion documents does riot authorize the violation of any adopted code or off. Receipt of approved y ard condions is acknowledged: By REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. 9///62/4" City Ofliskwlla BUILDING DIVISION L- z L-38,40,42 ELECTRICAL POWER PLAN (CONT.) N.O. IJ SCALE: 1/4" =.1' -0" ►© • REVIEWED FOR COMPLIANCE WITH NFPA70 - NEC JUN 21 2011 City of Tukwila BUILDING DIVISION ELii SCALE: 1/4" = 1-0" RECEIVED JUN 08 2011 PERMIT CENTER CONTRACTOR SHALL KEEP ALL. M, P $ E'5 THE HALLWAY AND TOILET ROOM TFORM AS TIGHT TO 114E SIDE WALL AS POSSIBLE. KEEP THE MAIN AREA OF TFORM CLEAR. EN CORE DRILLING FOR SALES AREA / ITTING ROOM FLOORING, KEEP CORING AS AS POSSIBLE WITH MINIMAL. 2' -6' 1' -b 5/8' RACK BACKBOARD Zs (3'-0' x 2' -6') it • - (2) 20AMP DEDICATED CIRCUITS. - L -33,35 (2) 4'x4' J -BOX FOR AUDIO CABLES. (1) SINGLE GANG:. J -80X FOR TELECOM PLATE/JACK. TENANT G.C. SHALL SUPPLY AND INSTALL AUDIO RACK PLYWOOD BACKING, INSTALL WITH STRUCTURAL RATED SCREWS OR LAGS. REFER TO SHEETS E600 AND E601 FOR COMPLETE INFORMATION AND DETAILS. POWER PLAN NOTES AUDIO SYSTEM POWER. ELEVATION SCALE B ELECTRICAL AT MGR'S DESK SCALE 16. STORE TELEPHONE JACK AT 46' A.F.F. AT STOCK ROOM DESK. RUN 3/4'C. WITH PULLWIRE TO T.T.B. 17. G.F.I. CONVENIENCE OUTLET MOUNTED IN WALL AT + 52' A.F.F. AT TOILET ROOM. 18. J -BOX FOR COMPLETE CONNECTION OF WATER NEATER. VERIFY EXACT LOCATION AND VOLTAGE WITH PLUMBING TRADE. 1q. 2' x 4' x 3/4' PLYWOOD TELEPHONE TERMINAL BOARD (T.T.B.). PROVIDE 1' E.G. TO TELEPHONE COMPANY POINT OF CONNECTION. VERIFY EXACT MOUNTING HEIGHT WITH OWNER. 20. QUADRUPLE< OUTLET MOUNTED ON OR NEAR T.T.B. PROVIDE WITH STAINLESS STEEL. COVER PLATE. 21. PUSH BUTTON MOUNTED AT +48' A.F.F. FOR CASH WRAP AREA BUZZER. 'EDWARDS' CAT. *1786 SERIES OR APPROVED EQUAL. 22. TIMECLOCK FOR STOREFRONT LIGHTS AND SIGN. MOUNT NEAR ELECTRICAL PANEL. SEE LIGHTING CONTROL DIAGRAM ON SWEET E300. 23. NEW PANEL 'L'. SEE SINGLE -LINE DIAGRAM ON SHEET E300. 24. NOT USED. 25. PROVIDE J -80X FOR COMPLETE CONNECTION TO DUCT SMOKE DETECTOR. INTERLOCK WITH HVAC UNIT TO PROVIDE SYSTEM SHUTDOWN IF SMOKE I5 DETECTED. PROVIDE LOW VOLTAGE TRANSFORMER SIZED AS REQUIRED. VERIFY EXACT LOCATION AND COMPLETE REQUREMENTS WITH MECHANICAL DRAWINGS. TIE -IN OR PROVIDE CONNECTION TO MALL'S FIRE ALARM SYSTEM AS REQUIRED. 26. NEW ROOF TOP CONDENSING UNIT (CU -1) AND AIR HANDLING UNIT (AHU -1). FLA- 413A, 208V, 3 -PHASE W/ q.96KW HEATING ELEMENT AND SINGLE POINT OF CONNECTION. PROVIDE WITH 60A, 3P, 240V, NEMA 3R DISCONNECT SWITCH WITH FRN -R FUSES SIZED PER MFR. SPECIFICATION. VERIFY EXACT LOCATION WITH MECHANICAL CONTRACTOR PRIOR TO ROUGH -IN. 27. J -80X FOR COMPLETE CONNECTION TO MECHANICAL CONTRACTORS' PROVIDED MOTORIZED DAMPER L.V. TRANSFORMER. VERIFY EXACT LOCATION WITH MECHANICAL CONTRACTOR PRIOR TO ROUGH -IN. 28. CEILING MOUNTED SMOKE DETECTOR. REFER TO TENANT CRITERIA FOR ADDITIONAL INFORMATIONS. SEE SHEET E300 FOR FIRE ALARM RISER DIAGRAM. 2q. COMBINATION HORN AND STROBE. REFER TO TENANT CRITERIA FOR ADDITIONAL INFORMATIONS. SEE SHEET E300 FOR FIRE ALARM RISER DIAGRAM. I. J -80X FOR STOREFRONT SIGN POWER TO BE INSTALLED IN SIGN TROUGH. PROVIDE DISCONNECTING MEANS AS REQUIRED BY N.E.C.VERIFY EXACT LOCATION IN FIELD. 2. CONVENIENCE OUTLET MOUNTED IN WALL AT +18' A.F.F. WHITE WITH WHITE COVER PLATE. CENTER SALES AREA OUTLETS BETWEEN STANDARDS. 3. ELECTRIC BUZZER MOUNTED IN CASH WRAP, ' EDWARDS' CAT. N0.720 DIXIE BELL, AC. CONNECT TO PUSH BUTTON AT SERVICE DOOR. VERIFY EXACT LOCATION WITH CONSTRUCTION MANAGER. 4. LOW VOLTAGE BELL WIRE IN 3/4' EMT CONDUIT BETWEEN PUSH BUTTON AT SERVICE DOOR AND BUZZER AT CASH WRAP AREA 5. DUPLEX CONVENIENCE OUTLET MOUNTED IN SOFFIT, WHITE WITH WHITE COVER PLATE. COORDINATE LOCATION WITH TRACK LIGHTS IN SOFFIT. 6. DEDICATED DUPLEX OUTLET WITH DEDICATED GROUND MOUNTED ABOVE SOFFIT FOR SENSORMATIC ANTI -THEFT SYSTEM POWER. COORDINATE ADDITIONAL SYSTEM INSTALLATION REQUIREMENTS WITH TENANT GC. REFER TO SHEET E400 FOR ADDITIONAL, DETAILS. 7. NOT USED 8. ELECTRIC BUZZER MOUNTED ON WALL ABOVE STOCK ROOM DESK, ' EDWARDS' CAT. N0.720 DIXIE BELL, AC. 9. J -BOX ON i WALL AT 88' A.F.F. IN STOCK ROOM FOR BUZZER. 10. DEDICATED DUPLEX OUTLET (HUBBEL OR EQUAL) WITH DEDICATED GROUND MOUNTED AT 46' A.F.F. AT STOCK ROOM DESK. QUADRUPLEX OUTLET MOUNTED AT 46' A.F.F. AT STOCK ROOM DESK. 12. CURRENT LIMITER SUB -PANEL 'CLS'. SEE SINGLE -LINE DIAGRAM ON SHEET E300. I$. EQUIPMENT RACK LOCATION. SEE AUDIO POWER SYSTEM ELEVATION DETAIL ON THIS SWEET. REFER TO SHEET E600 1 E601 FOR COMPLETE AUDIO SYSTEM REQUIREMENTS. 14. FIVE (5) GANG AND SINGLE GANG JUNCTION BOXES ON MANAGER'S DESK FOR AUDIO SYSTEM CONTROLLER. SEE ELEVATION DETAIL ON SHEET E102. REFER TO SWEET E60 FOR COMPLETE AUDIO SYSTEM REQUIREMENTS. 15. TELEPHONE JACK AT 46' A.F.F. FOR COMPUTER SYSTEM CONNECTION AT STOCK ROOM DESK. RUN 3/4'C. WITH PULLWIRE TO T.T.B. 530 pAcsun. HT NOTICE: TICE: O These drawings and specifications are copyrighted and subject to copyright protection as an "architectural work" under sec. 102 of the copyright act, 17 u.S.C. As amended January 2003. The protection includes, without limitation, the overall form, arrangement and composition of spaces, and elements of the design. Under such protection, unauthorized use of these drawings and specifications may result in cessation of construction, building seizure, and/or monetary liability. REVISION NUMBER AND DATE ANDREW C. PANOPIO P.E. 4115 N. 15TH AVE PHOENIX. AZ 85015 (602) 265 -1555 PROJECT NO. 1 1.09 6 DATE: 5/24/2011 SCALE: 1/4'1' -O' DRAWN 8Y: STAFF PROJECT No.: SHEET: E100 PSN -10 -016 A-'- C-- O 8 11 • • , SECTION A A-- 0 CASHWRAP SECTION C SECTION D NOTE: CUT NO BIGGER THAN 6" WIDE WITH MINIMAL OVER CUTS AND REPLACE REBARB II II 1 20 ENLARGED CASH WRAP DETAILS (LARGE CASH WRAP WITH 3 REGISTERS) SCALE A N.T.S. r1 ENLARGED CASH WRAP PLAN (LARGE CASH WRAP WITH 4 REGISTERS( SCALE N.T.S. re • e e e a m • SECTION A B+ SECTION B CASH WRAP • SECTION C ENLARGED BACK WRAP DETAILS (LARGE CASH WRAP WITH 3 REGISTERS SCALE N.T.S. WHEN TRENCHING FOR SALES AREA / FITTING ROOM FLOORING, KEEP TRANCN AS NARROW AS POSSIBLE WITH MINIMAL. OVERCUTS. REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC JUN 21 2011 City o u cw a BUILDING DIVISION CASH WRAP NOTES CASH WRAP POWER NOTES O O TELEPHONE AND DATA JACKS IN CASK WRAP COUNTER (RJ11 # RJ4S). RUN 3/4'C. WITH PUU.WIRE TO T.T.B. VERIFY EXACT LOCATION 14114 FIXTURE MANUFACTURER. QUADRUPLEX OUTLET MOUNTED 114 CASH WRAP COUNTER. MANUFACTURER. QUADRUPLEX OUTLET MOUNTED IN BACK WRAP COUNTER. MANUFACTURER. VERIFY LOCATION WITH FIXTURE VERIFY LOCATION WITH FIXTURE PUSH BUTTON MOUNTED IN CASH WRAP COUNTER CONNECTED TO BUZZER NEAR STOCK ROOM DESK. VERIFY EXACT LOCATION WITH CONSTRUCTION MANAGER. RIGID CONDUITS STUB -UP 2' ABOVE SLAB FOR AU. CASH WRAP SYSTEMS, (ia, OUTLETS, TEL/DATA AND LOW VOLTAGE SYSTEM). EXTEND TO THE DEVICES AS REQUIRED. GANG ALL CONDUITS TOGETHER AND RUN TO 114E DEVICES. CONDUITS IN CASH WRAP SHALL BE CONCEALED FROM VIEW. PRIOR TO CORE DRILLING VERIFY EXACT LOCATION 141114 ON SITE LANDLORD REP ANC X -RAY SLAB. RUN ALL ELECTRICAL., PHONES, AND 1.011 VOLTAGE SYSTEMS IN 3/4' RIGID CONDUITS TO STUB -UP AREA OF CASH WRAP. RUN UNDER SLAB FOR STUB -UPS IN CASH WRAP COUNTERS (BOTH SIDES). VERIFY METHOD OF SLAB PENETRATION (USUALLY CORING OR SAW CUTTING). X -RAY SLAB BEFORE DRILLING. COORDINATE WITH MALL AUTHORITIES PRIOR TO COMMENCE THIS WORK. PATCH AND REPAIR SLAB AS REQUIRED. COMPLY WITH MALL REGULATIONS. RUN CONDUITS TO NEAREST ADJACENT WALL OR COLUMN. (VERIFY). PULL. BOXES 0 13'-0' A.F.F. FOR CONNECTIONS TO ALL CASH WRAP STUB -UPS 11 Ell 0 6 0 0 0 10 D D D 20 QUAD OUTLET TIGHT TO SIDE AND BACK OF CABINET 3/4" RIGID CONDUIT 3/4' FLEX CONDUIT 3/41 RIGID CONDUIT (BEYOND) 3/4' FLEX CONDUIT (BEYOND) 3/4' RIGID STUBS AT 2' AFF TELEPI4ONE JACK T -1 DATA JACKS / TELEPHONE JACK CAT 5 PUSHBUTTON FOR STOCKROOM BUZZER. PRINTER HUB MODEM POWER PACK DOOR REMOVED FOR CLAIRTY PRINTER REMOVED FOR CLARITY ISOLATED DEDICATED CIRCUT (ORGANGE) J -BOX FOR POWER LOW VOLTAGE POWER CONDUIT DATA CONDUIT TELEPHONE CONDUIT RECEIVED JUN 082011 PERMIT CENTER POWER/ISOLATED POWER CIRCUT CONDUIT SERVICE DOOR BUZZER. VERIFY LOCATION 530 pAcsun. • COPYRIGHT NOTICE: These drawings and specifications are copyrighted and subject to copyright protection as an "architectural work" under sec. 102 of the copyright act, 17 u.S.C. As amended January 2003. The protection includes, without limitation, the overall form, arrangement and composition of spaces, and elements of the design. Under such protection, unauthorized use of these drawings and specifications may result in cessation of construction, building seizure, and/or monetary liability. E3) 0 0) cn _ % 1 1 - • oo co U * N co O u) • z J 0 W ANDREW C. PANOPIO P.E. 4115 N. 15TH AVE PHOENIX. AZ 85015 (802) 285 -1559 PROJECT NO. 1 1.096 DATE: 5/24/2011 SCALE: 1/41■1' -01 DRAWN BY: STAFF PROJECT No.: SHEET: E101 PSN -10 -016 • ••••• ................................................................................................ . ...... ... ..... ..... .... .... u "N Nan! ALL SALES LIGHTING SI-IALL BE CONTROLLED TI-IRU THREE LIGHTING CONTACTORS (C-1, C-2, C-3) THE TENANT GC SHALL PROVIDE, INSTALL. AND W IRE THESE CONTACTORS. SEE LIGHTING CONTROL DIAGRAM ON SWEET E300. u L-1 (TIE-IN) u • NL L-9 ••- •• • • • • ,• • • • • e • •'"•-•••• • • , ••••••.' ..... ••• • • , • • ••,.,• '• • , • • • • • , • • • • •• L-11,13 • „ LJ23 g (TIE-IN) L-27 • •••, • • • • • - - - - - - - - „ „• . . . •„ , , . • .. . - • • •••• •••• •••• ... GI 4,41 4441 GI ki 17 L-25 4,41 444,1 L-15,17 15 NL 1 19 u :u 1.-19, 21 `. L-23 !. ., . : •••. .:: .„..„....„_„..„.. ..................................... .. ..... . ................... ▪ ,.....::•.:::.:::,,,..:::=::::::, ••••• " . .„ . .. . ' ••••• •-•• •"-• ••••• ,„. •-•• „„„.. •"•• •••"•-• ••••••• ••••••••• •••,••• ELECTRICAL LIGHTING PLAN Harm THE REQUIRED EMERGENCY LIGHTING INTENSITY SHALL BE PER IBC 1006.4 AND SI-IALL BE INSTALLED ALONG THE MAIN EGRESS AISLE. GENERAL NOTES 1. WIRI ING IN MEN CEILING SPACE SHALL BE IN EMT CONDUIT UNLESS FLEXIBLE CONDUIT IS REQUIRED. ONLY C.M. CAN APPROVED USE OF FLEXIBLE CONDUIT. EMERGENCY LIGHTS IN SALES AREA ARE TO SE PAINTED TO MATCH SURROUNDING COLOR. 2. ALL ELECTRICAL CONDUITS ARE TO BE MOUNTED AS HIGH AS POSSIBLE OR HIDDEN, CONTACT C.M. IF QUESTIONABLE. 3. CONTRACTOR SHALL KEEP ALL. M, P *E'S OVER THE FITTING ROOM, HALLWAY AND TOILET ROOM PLATFORM AS TIGHT TO THE SIDE WALLS AS POSSIBLE. KEEP THE MAIN AREA OF THE PLATFORM CLEAR. 4. SEE SHEET E300 FOR LIGHT FIXTURE SCHEDULE. 5. LIGHT SWITCHES, ELECTRICAL. OUTLETS, THERMOSTATS, AND OTHER ENVIRONMENTAL CONTROLS SHALL HAVE OPERABLE PARTS OF THE CONTROLS LOCATED NO HIGHER THAN 48' AND NO LOVER THAN 15' ABOVE FINISHED FLOOR. IF THE REACH IS OVER AN OBSTRUCTION BETWEEN 20' AND 25' IN DEPTI4, THE MAXIMUM HEIGHT IS REDUCTED TO 44' FOR FCRWARD APPROACH OR 46' FOR SIDE APPROACH, PROVIDED THE a3STRUCTION IS NO MORE THAN 24' IN DEPTH. OBSTRUCTIONS SHALL NOT EXTEND MORE 1146,N 25' FROM THE WALL BENEATH A CONTROL. 6. PLACEMENT OF SPEAKERS AND AUDIO EQUIPMENT TO BE BY 'AUDIO VENDOR'. SEE SHEETS E600 AND E601 FOR EXACT PLACEMENT AND COMPLETE REQUIREMENTS. 7. ALL LOW VOLTAGE WIRING INCLUDING SPEAKER WIRING SHALL BE RUN IN CONDUIT. 8. ALL ELECTRICAL CONDUIT ARE TO BE MOUNTED AS HIGH AS POSSIBLE OR HIDDEN. 9• ALL UTILITIES INSTALLED VERTICALLY NEED TO BE RAN TIGHT TO WALLS. REFER TO ARCHITECTURALS. (10. ALL SUSPENDED TRACK 'TO BE INSTALLED PER DETAIL 10/A701. 11 . TOILET ROOM MOTION SENSOR TO BE INSTALLED WITHIN A 48i HEIGHT. . •••'• ••,'•• • .."‘. •••• • • • ••• •••• ••■ • •■ • • ......... • • • • • • • • • • • •_• • •■•.• • •.• • •.• •-•.• ....... ....• • • • • • ••• • • ....... .. -• *%:*. , „.„.01 .,„41 . .„,401 , , • -...,%„.••• ••,,•• • , • - • pr • LI -1, 3 GI % „••• „.0 % • " &GI -41 L-3,5 VIA TIMECLOCK NL > 1 '34 (TYP. ) •• • •••,•••• • •• • • • • •:•• • • •x •• • • • • ..,,,• •• ••• • •• • • • ••••:. ••••• • s k.:‘,..,•• • •• • - • • • ZI ci w • ■•• ■kwo • .■ ■■■ ■•■■ =w. m.■ . . .. U H ,. ; Uy.... „„ ,... " H ::. •• '• ., :: SCALE: 1/4" 11-0" NL u • • - • , . ... „„. TIE- IN) •"•- •'• .„„ • ''‘" •-• •-•-• • • • ••••• ••••-• •".` •"•-• ••-• -'`••• •-"•••• ..... .• „•••••••• ELECTRICAL LIGHTING PLAN (CONT.) k SCALE: 1/4" .1 1'-O" REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC SE? 0 7 2011 City of Tukwila BUILDING DIVISION REVISION Nal_ RECEIVED EL IA-. 0 52.3 AUG 25 2011 PERMIT CENTER ELECTRICAL LIGHTING PLAN NOTES LIGI4T FIXTURES BEHIND MIRROR 96" t RECESSED DUPLEX OUTLET MOUNTED ON CENTER BEHIND MIRROR FOR MIRROR LIGHTS 'PLUG-IN' PCNER. REFER TO SHEET • E100. 112 MIRROR ELEVATION I SCALE I A I N.T.S. 0 EXIT LIGHT WITH I4 SELF-CONTAINED BATTERY BACK-UP, CONNECT AHEAD OF ANY SW I TO-I I NG DEVICES. (M IN I M UM 9C) MIN. ILLUMINATION UPON LOSS OF AC POWER). EMERGENCY LIGHT WITH SELF-CONTAINED BATTERY BACK-UP. CONNECT AHEAD OF ANY %V ITCI-1 I NG DEVICES. (MINIMUM OF 9C) MINUTES I LLUM !NATION UPON LOSS OF AC powER. ) N IGHTL I GI-IT (NL) CONNECT AHEAD OF ANY SW ITCI4 I NG DEVICES (TYPICAL). ( UNSW I TO-IED) REFER TO DETAIL L A FOR MIRROR ELEVATION, THIS 51EE-r. 1/41ALL. SWITCH SENSOR (PI R) 1-1U1313EL 'IL I GI-ITHAWKI CAT. NO. L,14-1R-st-H CEILING MOUNTED SENSOR (MULTI -TECI-INOLOGY) AT 12'-. HUBBEL L I GI-ITOWL" CAT. NO. 1.0- DT-W MP SERI ES POWER PACK. 14U1313EL 'A' SERIES CAT. NO. MP-120A, VERIFY LOCATION IN FIELD. SPST 20 A, 120V OVERRI DE SW ITCI-1 W ITI-I 1941-11TE • COVER PLATE. • J-130X FOR COMPLETE CONNECTION TO FUTURE VISUAL EQUIPMENT. VERIFY Y EXACT LOCATION PRIOR TO ROUGH-4N. 530 pocsun• COPYRIGHT NOTICE: These drawings and specifications are copyrighted and subject to copyright protection as an "architectural work" under sec. 102 of the copyright act, 17 u.S.C. As amended January 2003. The protection includes, without limitation, the overall form, arrangement and composition of spaces, and elements of the design. Under such protection, unauthorized use of these drawings and specifications may result in cessation of construction, building seizure, and/or monetary liability. z z w w 0 0 1E101 2 0 c7) w5 5 0_ a 9 0_ 0_ a_ ANDREW C. C. PANOPIO P.E. 4115 N. 15TH AVE PHOENIX. AZ 85015 (602) 265-1559 PROJECT NO. 11.096 08-22-11 DATE: SCALE: 5/24/2011 1/4" ■1' -0" DRAWN BY: STAFF PROJECT No.: SHEET: E200 PSN-10-016 SINGLE -LINE DIAGRAM.T.S. IMPORTANT jkagi INFORMATION SHOWN ON ONE -LINE DIAGRAM 15 BASED ON LANDLORD INFORMATION. E.C. SHALL VISIT SITE TO VERIFY EXISTING ELECTRICAL CONDITIONS PRIOR TO SUBMITTING BID. BID SHALL INCLUDE ALL COST REQUIRED TO MODIFY EXISTING SYSTEM AS REQ'D. TO ACCOMODATE NEW WORK. NOTES 1. THE ELECTRICAL CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO SID. 2. PROVIDE ENGRAVED NAMEPLATES ON EACH SERVICE, PANEL, TRANSFORMER, DISCONNECT SWITCH, MOTOR STARTER, ECT. 3. PROVIDE LISTING OF ALL BREAKERS, CLEARLY TYPED AND PERMANENTLY ATTCI.IED INSIDE THE DOOR OF EACH CIRCUIT BREAKER PANEL. 4. ALL WORK IN LANDLORD'S DISTRIBUTION SECTION SHALL SE PERFORMED BY LANDLORD'S CONTRACTOR AT TENANT EXPENSE. 5. ALL CONDUCTORS SHALL BE COLOR CODED AS REQUIRED BY TENANT CRITERIA MANUAL AND N.E.C. EXISTING LANDLORD'S DISTRIBUTION SWITCHBOARD 120/208V, 3PH, 414 LANDLORD SPACE TENANT SPACE F1- 7, 957A :�C.... TO CURRENT TRACK -.4 . -•• LIMITER x. LIGHTS ® UBPANEL, 'CLS' { MINIMUM 2' CODUIT. NUNMBER OF CONDUITS AS REQUIRED. REUSE EXIST. METER PER POWER CO. AND L.L. REQUIREMENTS. EXIST. 200A, 3P, DISC. SWITCH W/ (3) 200A FUSES. '(PROVIDE NEW IF NOT ;FOUND EXIST.) EXIST. 4 *4/0 (THW) CU., 1 1a'6 CU. GRD., IN EXIST. 3- 1/2 "C. EXTEND FEEDERS AND CONDUIT TO NEW PANEL LOCATION. (VERIFY EXACT ROUTING IN FIELD) NEIN 200A 3P MCB PANEL "L' (NEW) NEW 200A `> 3P MCB PANEL "L' (NEW) NEW 4 *6 (TWAIN) CU., 1 #10 CU. GRD., IN 1" C. CURRENT LIMITER SUB -PANEL "CLS" #T24 -12 -SM Breaker # Line Circuit, .., .. Limit Rating (Amps.)•• 1 ; L -5 ' 2 2 ••. L -11 1 r' 3 L -13 ( 1 •: 4 '. L-15 ,: 1 =:.' 5 ::• L -17 " 1 6 % L -19 1 =' 2' 'LITHONIA LIGHTING' •SS- 1- 17- MVOLT- GEB1ORS' MIRROR COVE LIGHTING SYSTEM A 8 . L -23 c 1 9 '? SPACE (1) 25W / 120V F025T8/830 / 27W 10 0 — - 11 SPACE - 12 SPACE - ROUTE ALL TRACK LIGHTING CIRCUITS FROM BREAKER PANEL 'L' TO 'CLS' LANDING EACH TRACK CIRCUIT ON THE INPUT SIDE OF THE SUPPLEMENTARY BREAKER DESIGNATED BY JUNO LTG. A '"(C11.1.1F1= 11111J11 ELECTRICAL EQUIPMENT ELEVATION TIMECLOCK PNL 'L' PNL CLS TO L.L. ELEC. RM. P WORKING SPACE FLOOR PLAN LANDLORD SPACE TENANT SPACE EXIST. PULL. BOX PNL CLSO PNL 0 PNL L1 FRONT ELEVATION MARK SYMBOL MFGR. / DESCRIPTION RESP LAMPS C 200A ME CA MAINS 1 BOLT -ON TYPE 'JUNO' LINE VOLTAGE TRACK, 743751.- SILVER WITH BLACK ADJUSTING A 60W PARSE: (1) VNSP7 CAP 'SYLVANIA' 1 CKT 'JUNO' LINE VOLTAGE TRACK, T437SL SILVER WITH BLACK ADJUSTING BUTTON A (1) 10W PARSES LAMP, 7 DEGREE BEAN ANGLE. D . ' 'JUNO' 6' RECESSED DOWNLIGHTS, HOUSING- SP696HTC, TRIM- SP6g6THZWH A MAX ; HA OGE HALOGEN IR+ G1 2' 'LITHONIA LIGHTING' •SS- 1- 17- MVOLT- GEB1ORS' MIRROR COVE LIGHTING SYSTEM A (1) 17W / 120V F017T6/830 / 22W G2 = 'LITHONIA LIGHTING' •SS- 1- 25- MVOLT- GEB1OR5' MIRROR COVE LIGHTING SYSTEM A (1) 25W / 120V F025T8/830 / 27W U — 'LITHONIA LIGHTING' #C 1 32 120 GEB 3 (1) F32 T8 120V. / 32W MAX X 2 'JUNO' *NXP133RWN ILLUM. EXIT SIGN W/ SEALED, MAINTENANCE -FREE NICKLE CADMIUM BATTERY. (3.1 WATTS MAX.) (NON - SALES) A 120V / 277 VAC X1 3 'JUNO' #NXESB1RAA ILLUMINATED EXIT SIGN W/ SEALED, MAINTENANCE -FREE NICKLE CADMIUM BATTERY. (4.8V, 1.27 WATTS MAX.) (SALES - EDGE LIT - 1 SIDED) A 120V / 277 VAC X2 RECEPT - C/W PRINTER 'JUNO' #NXES132RAA ILLUMINATED EXIT SIGN W/ SEALED, MAINTENANCE -FREE NICKLE CADMIUM BATTERY. (4.8V, 1.27 WATTS MAX.) (SALES - EDGE LIT - 2 SIDED) A 120V / 277 VAC 5 4 SURFACE MOUNTED DUAL. HEAD EMERGENCY LIGHT UNIT W/ COMPACT BATTERY PACK. ,q 120V / 277 VAC ?201 5 5000 20 /1 RECEPT - CASH WRAP QUAD 12 3 360 6 :..,.:• 1,5 ... .......:...... 12 ::..:......:....: ,...:.......:..:-.,::;. ....:.....:,•.,...;:..,...:...' LIGHTS - MIRROR COVE (FITTING RIMS.) 20/1 7 1225 20/1 RECEPT - BACK WRAP QUADS 12 3 720 S 1,5 12 LIGHTS - FITTING ROOMS DN. LTS /EM /EXIT 20/1 NOTE: EXIT AND EMERGENCY LIGHT FIXTURE TYPES AND LOCATIONS ARE SUBJECT TO BUILDING DEPARTMENT AND FIRE DEPARTMENT APPROVAL. 20/1 RESPONSIBILITY CODE: A FURNISHED BY PACIFIC SUNWEAR INSTALLED 8Y TEN. G.G. 8 FURNISHED AND INSTALLED BY TEN. G.G. NOTE: IN ORDER TO INSURE PROMPT DELIVERY OF THE LIGHT FIXTURES, PACIFIC SUNWEAR HAS PRE- ORDERED ALL FIXTURES SPECIFIED. THE ELECTRICAL CONTRACTOR SHALL FURNISH ALL. LABOR AND MATERIALS - EXCLUDING OWNER SUPPLIED UNITS - AND MUST MAKE ARRANGEMENTS TO RECEIVE THE FIXTURE SHIPMENT AND INSPECT AND FILE ALL CLAIMS FOR DAMAGE AGAINST THE COMMON CARRIER. DAMAGED FIXTURES, SHORTAGES OR WRONG VOLTAGE SHOULD BE PROMPTLY REPORTED TO PACIFIC SUNWEAR CONSTRUCTION MANAGER: (714) 414 -4038, WITHIN 24 14R5. OF INSPECTION OF SHIPMENT. THEREAFTER, THE ELEC. CONTRACTOR 15 RESPONSIBLE TO REPLACE ANY MISSING PARTS AT HIS EXPENSE. PANEL SCHEDULES / LOAD CALCULATIONS RESPONSIBILITY SCHEDULE NOTES 1, ELECTRICAL PANELBOARD DIMENSIONS ARE BASED ON SQUARE D PRODUCT. TYPICAL SQUARE D DIMENSIONS FOR A 200A, 42 POLES PANELBOARD ARE (.46' 14 x 20 11W x eV). PANELBOARD HEIGHTS VARIES WITH NUMBER OF POLES. DIMENSIONS MAY VARY WITH OTHER MANUFACTURER. 2. ALL DIMENSIONS 514010IN ARE DIAGRAMMATIC IN NATURE. ACTUAL DIMENSIONS AND SIZES SHALL BE VERIFIED IN FIELD. REFER TO PANEL SCHEDULES FOR RATINGS AND SIZES OF EACH PANELSOARD AND TRANSFORMER. ALL WORKING SPACE (CLEARANCES) SHALL BE PER NEC 110.26, LIGHTING CONTROL DIAGRAM 120 VOLT CONTROL CIRCUIT "L -32" INTERMATIC *T740113, 4PST, 120V I E ► 'L'- 3,5,24,34) r) C1 L "L"-171,17,2423 5 \ LIGHTS - TRACK/CASH WRAP SALES FLOOR STOREFRONT • AND SIGNS TRACK LIGHTS. PERIMETER WALL 'L'- 13, 15, 17,19;:25,27! ` DOWN/COVE LIGHTS. FITTING RMS. 'L'- 7,9 FURNISHED 4 INSTALLED ITEM LANDLORD DISTRIBUTION PANEL CONDUIT TO SPACE EXTEND CONDUIT WITHIN SPACE :...::::. WIRE TO SPACE EXTEND WIRE IN SPACE DISCONNECT WITHIN SPACE TRANSFORMER PANEL L PANEL LI PANEL H HOMERUNS/CCNDUITS/WIRES LIGHTING SENSOR SWITCHES CURRENT LIMITER SUS-PANEL 'CL51 TELEPHONE CONDUIT TO SPACE FriSSAUFSisi fAIRISVVE ...:)..:: BUZZER SYSTEM LIGHT FIXTURES 1— T • • • • VERIFY AVAILABILITY FOR LOAD DEMAND TEN. G.C. TO UPSIZE IF REQ. VERIFY AT BID NOT USED • NOT USED PROVIDE NEW NOT USED . ..... . . .. .. .. .. . .. ..: .. .. .. ... .. . . ... :. . .. .. .. . • NOT USED • TENANT G.C. TO EXTEND AS REQ. VERIFY SERIES RATED 65 /10KAIC PANELBOARD SCHEDULE L 10,000 A.I.C. BREAKER MINIMUM POINT OF CALCULATED FAULT 120 / 208 VOLTS 1 3 PHASE I 4 WIRE SURFACE MOUNTED 200A ME CA MAINS 1 BOLT -ON TYPE NOTE WIRE SIZE USE AND / OR AREA SERVED C / B CKT LOADS CKT C / B USE AND / OR AREA SERVED W'RE SIZE NOTE NO Ph A Ph B I Ph C NO 1 12 LIGHTS - STOCKRM /HALLWAY/TOILEf /EM /EX :.....;•••... 20/1 1 1040 TO COMPLY WITH NEC 110.22 AS FOLLOWS SERVICE SHALL READ: j EACH DOWNSTREAM PANEL TO READ: SERIES RATED SYSTEMS: BE MADE TO THE SYSTEMS WITHOUT PRIOR ABOVE. SCHEDULES FOR PANEL RATING. CAUTION - SERIES COMBINATION RATED 65,000 AMPERES. SYSTEM IDENTIFIED REQUIRED. SYSTEM IDENTIFIED REQUIRED. ELECTRICAL ENGINEER AND THE ELECTRICAL 20/1 RECEPT - C/W DEDICATED QUAD 12 3 360 2 1,2 12 LIGHTS - STOREFRONT DOWNLIGHTS :20/1 3 750 20/1 RECEPT - C/W PRINTER 12 3 5 4 1,2 12 LIGHTS - STOREFRONT (CLS #1) ?201 5 5000 20 /1 RECEPT - CASH WRAP QUAD 12 3 360 6 :..,.:• 1,5 ... .......:...... 12 ::..:......:....: ,...:.......:..:-.,::;. ....:.....:,•.,...;:..,...:...' LIGHTS - MIRROR COVE (FITTING RIMS.) 20/1 7 1225 20/1 RECEPT - BACK WRAP QUADS 12 3 720 S 1,5 12 LIGHTS - FITTING ROOMS DN. LTS /EM /EXIT 20/1 562 20/1 20/1 RECEPT - SHOW WINDOW 12 10 1,5 12 LIGHTS - TRACK LIGHTS (CLS #2) .. '.20/1 11 500 80 12 20/1 RECEPT - SHOW WINDOW 12 0 12 1,5 12 LIGHTS - TRACK LIGHTS (CLS #3) ''20/1 ' 13 113 20/1 RECEPT - SALES ARE(WALL) 12 720 14 1,5 12 LIGHTS - TRACK LIGHTS (CLS #4) (20/1 15 20/1'; RECEPT - SALES ARE (WALL) 12 900 16 1,5 12 LIGHTS - TRACK LIGHTS (CLS #5) 20/1 i 7 2400 30/1. WATER HEATER 10 4 18 1,5 12 LIGHTS - TRACK LIGHTS (CLS #6) `•;20/1 '20 /1 19 30/1? WATER HEATER 10 4 2400 20 1,5 12 LIGHTS - TRACK LIGHTS (CLS #7) 21 103 20/t, SPARE 22 1,5 12 LIGHTS - TRACK LIGHTS (CLS #8) 20 /1 ' 23 2011 STOREFRONT SIGNAGE 12 1,2 1500 24 1,5 12 LIGHTS - CASH WRAP AREA 20/1 '25 880 20/1 RECEPT - DED. DUPLEX (STOCK RM. DESK) 12 26 1,5 12 LIGHTS - CASH WRAP AREA 20/1 20/1 RECEPT - QUAD (STOCK RM. DESK) 12 .7 360 28 1,3 12 LIGHTS - EXIT /EM /NL 20/1 : 29 20/1 RECEPT - T.T.B. 12 360 30 SPARE 20/1 '.31 0 20/1 01 TIM ECL NTA T R OCKICO C O 12 3 200 — 32 12 RECEPT- STOCK RM/TOILEFS /REF. 20/1 `33 20/1 STOREFRONT BLADESIGNAGE 12 1,2 5 15 0 34 3 12 DUCT SMOKE DETECTOR 20/1 400 20/1 MOTORIZED DAMPERS 12 200 36 6 SUB -PANEL "L1" 50/3 60 /3 CU- 1 /AHU -1 (NON- COINCIDENTAL LOAD) 4 •`37 4956 38 6 " - :: 39 FLA =41.3 (CLG) / 12.1 KW (HTG) 4 4956 40 6 „ _ ,•41 1000 4 4956 42 �, TOTAL LOADEI PHASE 13866 13423 12731 13866 VA / 120 V = 116 AMPS SERIES RATED 65/10KAIC PANELBOARD SCHEDULE L1 ,:.._.,.. -, - -.... /5\ 10,000 A.I.C. BREAKER MINIMUM POINT OF CALCULATED FAULT 120 1 208 VOLTS I 3 PHASE I 4 WIRE SURFACE MOUNTED '% 200A MLO' 'MAINS I BOLT -ON TYPE NOTE WIRE SIZE USE AND / OR AREA SERVED C / B CKT LOADS CKT C / B ....USE'ANb / OR AREA SERVED WIRE SIZE NOTE NO Ph A Ph B 1 Ph C NO 1 12 J -BOX (FUTURE VISUAL DISPLAY) 20/1 1 5 00 TO COMPLY WITH NEC 110.22 AS FOLLOWS SERVICE SHALL READ: j EACH DOWNSTREAM PANEL TO READ: SERIES RATED SYSTEMS: BE MADE TO THE SYSTEMS WITHOUT PRIOR ABOVE. SCHEDULES FOR PANEL RATING. CAUTION - SERIES COMBINATION RATED 65,000 AMPERES. SYSTEM IDENTIFIED REQUIRED. SYSTEM IDENTIFIED REQUIRED. ELECTRICAL ENGINEER AND THE ELECTRICAL 20/1 SPARE REPLACEMENT COMPONENTS APPROVAL FROM THE DESIGN 0 2 12 J-BOX (FUTURE VISUAL DISPLAY) 20/1 3 5000 20 /1 SPARE 4 12 RECEPT - STEREO SYSTEM 20/1 5 5000 20/1 SPARE 6 12 RECEPT - STEREO SYSTEM 20/1 7 500 20/1 SPARE $ 3 12 RECEPT - ANTI -THEFT SYSTEM 20/1 9 500 20/1 SPARE 10 12 RECEPT - EDF (HALLWAY) 20/1 1 500 20 /1 SPARE 0 12 TOTAL LOAD PER PHASE 1000 1 1000 1000 1000 VA / 120 V = 8 AMPS PANELBOARD SCHEDULE NOTES: 1 - CONTINUOUS LOAD OR LARGEST MOTOR TAKEN AT 1 25%. 2 - THRU 24/7 DIAL TIMECLOCK (REFER TO LTG. CONTROL DIAGRAM) 3 - CIRCUIT BREAKER WITH LOCK -ON DEV ICE 4 - CIRCUIT BREAKER CAPABLE OF BEING LOCK IN THE OPEN POSITION 5 - THRU LIGHTING CONTACTORS (REFER TO LTG. CONTROL DIAGRAM) 6 - NOT USED 7 - NON - COINCIDENTAL LOAD (LARGESTOFCLG/HTG LOAD USED.) � Z3 LOAD CALCULATIONS LIGHTS at 125% SIGN at 125% OUTLETS, MISC. POWER (1ST 10KVA at 100 %) REMAINDER at 50% WATER HEATER at 100% HVAC: LARGEST LOAD AT 25% *HVAC AT 100 % DUCT SMOKE DETECTOR AT 100 % 7,082 3,000 9,870 4,800 1,239 14,868 400 VA VA VA VA VA VA VA VA VA TOTAL DEMAND LOAD TOTAL AMPS AT 208N, 3Ph, 4W 41,259 VA 115 AMPS * NON - COINCIDENTAL LOAD FIRE ALARM RISER DIAGRAM FAULT CURRENT CALCULATIONS 0 LIGHTING CONTROL KEYED NOTES 1. LIGHTING CONTACTOR SWITCH 20A, 120V, SINGLE POLE SINGLE THROW. SEE SHEET 6200 FOR LOCATION. (TYPICAL) 2. LIGHTING CONTACTOR, ELECTRICALLY HELD, 120V COIL IN NEMA 1 ENCLOSURE. SIZE NUMBER OF POLES AS REQUIRED. USE SQUARE D 'TYPE L' PRODUCTS WITH CAT. NOS. LISTED BELOW: 1LG40' (4 POLES), 'LW' (6 POLES), 'LG80' (6 POLES), 'LG1000" (10 POLES), 'LG1200' (12 POLES), 3. 40A, 120/277V TIMECLOCK LOADS. (TYPICAL OF 4) 4. BYPASS TIMER SWITCH. ADJUSTABLE 0 -120 MINUTES MAXIMUM. LOCATE ADJACENT TO CONTACTOR SWITCHES. CONDUIT G WIRE 8Y TENA N EXISTING F.A. J -BOX AT TENANT DEMISING WALL. TIE -IN SHALL BE SY THE L.L. CONTRACTOR AT THE TENANT'S EXPENSE. WIRE TO EXISTING FIRE ALARM PANEL SMOKE DETECT SEE PLANS FOR QUANTITY. AUDIOVISUAL STATIONS REFER TO PLANS FOR QUANTITY. VISUAL STATION ONLY. REFER TO PLANS FOR QUANTITY NOTES: . ELECTRICAL CONTRACTOR SHALL CONFIRM COMPLETE FIRE ALARM SYSTEM REQUIREMENTS WITH FIRE MARSHALL OR ANY LOCAL AGENCIES HAVING JURISDICTIONS. A COMPLETE OPERATIONAL AND APPROVED FIRE ALARM SYSTEM FOR 11415 PROJECT 15 DEEMED PART OF THE ELEC. CONTRACTOR'S CONTRACT. 11415 SYSTEM SHALL BE COMPATIBLE WITH THE MALL FIRE ALARM SYSTEM. 2. ALL CONNECTIONS, OR MODIFICATIONS TO LANDLORD'S FIRE ALARM SYSTEM ARE TO BE COMPLETED BY LANDLORD'S AUTHORIZED CONTRACTOR. CONTACT MALL MANAGEMENT FOR DETAILS. 3. REUSE OF EXISTING DEVICES, WIRING, ECT. IS SUBJECT TO COMPLIANCE W/ REQUIREMENTS SET FORTH IN THE CRITERIA MANUAL, BLDG. DEPT. AND LANDLORD APPROVAL. VERIFY ANY DEVICES, ECT. NOT ALLOWED FOR REUSED W/ THE BLDG. DEPT. AND THE LANDLORD'S DIRECTOR OF OPERATIONS/CHIEF ENGINEER PRIOR TO APPROVAL OF PLANS. FAULT CURRENT CALCULATIONS (THREE PHASE) MARK FAULT ORIGIN POINT OF CALCULATED FAULT FAULT @ ORIGIN AFC1 ■ LINE VOLTS EL CU -MAC-1 CU- NMAG_2 AL -MA3 AL- NMACc4 CU -NM SERI =S AL -NM SERI =6 WIRE LENGTH L WIRE SIZE NO OF SETS N "C" VALUE FACTOR FACTOR CALCULATED FAULT AFC2 "" F1 S.E.S. PANEL 'L' 65,000 208 1 200 4/0 1 15082 7.17 0.12 7,957 SERIES RATING NOTES: TO COMPLY WITH NEC 110.22 AS FOLLOWS SERVICE SHALL READ: j EACH DOWNSTREAM PANEL TO READ: SERIES RATED SYSTEMS: BE MADE TO THE SYSTEMS WITHOUT PRIOR ABOVE. SCHEDULES FOR PANEL RATING. CAUTION - SERIES COMBINATION RATED 65,000 AMPERES. SYSTEM IDENTIFIED REQUIRED. SYSTEM IDENTIFIED REQUIRED. ELECTRICAL ENGINEER AND THE ELECTRICAL 1. PROVIDE ENGRAVED NAMEPLATES A. NAMEPLATE AT B. NAMEPLATE AT FOR TWO TIERED 2. NO DESIGN CHANGES MAY INSPECTOR. ** DENOTES CALCULATED FAULTAFC2 NOTE: REFER TO PANELBOARD REPLACEMENT COMPONENTS CAUTION - SERIES COMBINATION RATED 65,000 / 10,000 AMPERES. REPLACEMENT COMPONENTS APPROVAL FROM THE DESIGN REVISION NO. _ L REVIEWED FOR COMPLIANCE WITH NFPA 70r NEC SO 0 7 2011 City 4 ukwila BUILDING DIVISION RECEIVED AUG 25 2011 PERMIT CENTER 530 PAcsuR. COPYRIGHT NOTICE: These drawings and specifications are copyrighted and subject to copyright protection as an "architectural work" under sec. 102 of the copyright act, 17 u.S.C. As amended January 2003. The protection includes, without limitation, the overall form, arrangement and composition of spaces, and elements of the design. Under such protection, unauthorized use of these drawings and specifications may result in cessation of construction, building seizure, and /or monetary liability. .Q C O o Q G � � a) (/) 4E' -th ci) ,92 C +� U O � (/) • � O O LO (/) CO I— REVISION NUMBER AND DATE z a 1 9 D. rs, a ANDREW C. PANOPIO P.E. 4115 N. 15TH AVE PHOENIX. AZ 55015 (602) 265 -1559 PROJECT NO 08 -22-11 DATE: SCALE: 5/24/2011 1/4'2•1' -0' DRAWN BY: STAFF PROJECT No.: SHEET: E300 PSN -10 -016 NOTES ELECTRICAL SYMBOLS LIST GENERAL ELECTRICAL NOTES ANTI -TH EFT SYSTEM DETAIL N.T.S. PROVIDE ENGRAVED NAMEPLATES ON PANELBOARDS, DISCONNECT SWITCHES, TRANSFORMERS, ETC. INDICATING EQUIPMENT DESIGNATION (OR DESIGNATION OF EQUIPMENT SERVED) AND VOLTAGE. 2. VERIFY LOCATION OF ALL FLOOR OUTLETS WITH ARCHITECT PRIOR TO ROUGH -IN. 3. DATA, TELEPHONE AND TELEVISION CONDUIT SHALL BE MINIMUM 3/4° UNLESS OTHERWISE NOTED ON DRAWINGS. DO NOT SCALE DRAWINGS. VERIFY DIMENSIONS IN FIELD PRIOR TO COMMENCEMENT OF WORK. • FINAL CONNECTIONS TO EQUIPMENT SHALL BE PER MANUFACTURER'S APPROVED WIRING DIAGRAMS, DETAILS AND INSTRUCTIONS. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO PROVIDE MATERIALS AND EQUIPMENT COMPATIBLE WITH EQUIPMENT ACTUALLY • SUPPLIED. ALL EMPTY RACEWAY SYSTEMS SHALL HAVE A PULLWIRE OR EQUAL AND SHALL BE IDENTIFIED AT ALL. JUNCTION, PULL AND TERMINATION POINTS, USING PERMANENT METALLIC TAGS. TAG 7. SHALL INDICATE INTENDED USE OF CONDUIT, ORIGINATION AND TERMINATION POINTS OF EACH INDIVIDUAL CONDUIT. IT I5 THE INTENT OF THESE DRAWINGS AND SPECIFICATIONS TO 8. ESTABLISH A STANDARD OF QUALITY. THE ENGINEER RESERVES THE RIGHT TO APPROVE METHODS AND MATERIALS NOT REFLECTED 0. HEREIN. EXAMINATION OF BIDDING DOCUMENTS: EACH BIDDER SHALL EXAMINE THE BIDDING DOCUMENTS CAREFULLY AND, 140T LATER THAN SEVEN DAYS PRIOR TO THE DATE OF RECEIPT OF BIDS, SHALL MAKE WRITTEN REQUEST TO THE ARCHITECT FOR INTERPRETATION OR CORRECTION OF ANY DISCREPANCIES, AMBIGUITY, INCONSISTENCY, OR ERROR THEREIN WHICH HE MAY DISCOVER. ANY INTERPRETATION OR CORRECTION WILL BE ISSUED AS AN ADDENDUM 8Y THE ARCHITECT. ONLY A WRITTEN INTERPRETATION OR CORRECTION BY ADDENDUM SHALL BE BINDING. NO BIDDER SHALL RELY UPON INTERPRETATIONS OR CORRECTIONS GIVEN BY ANY OTHER METHOD. IF DISCREPANCIES, AMBIGUITY, INCONSISTENCY, OR ERROR ARE NOT COVERED BY b. ADDENDUM OR WRITTEN DIRECTIVE, CONTRACTOR SHALL INCLUDE IN 1415 SID,' LABOR, MATERIALS, AND METHODS OF CONSTRUCTION RESULTING IN HIGHER COST. AFTER AWARD OF CONTRACT, NO ALLOWANCE OR EXTRA COMPENSATION WILL BE MADE IN BEHALF OF THE CONTRACTOR DUE TO 1415 FAILURE TO MAKE THE WRITTEN REQUESTS AS DESCRIBED ABOVE. 9. THE PERSON SUBMITTING THE REQUEST WILL BE RESPONSIBLE FOR ITS PROMPT DELIVERY. FAILURE TO 50 REQUEST CLARIFICATION OF ANY INADEQUACY, OMISSION, OR CONFLICT WILL NOT RELIEVE THE CONTRACTOR OF RESPONSIBILITY. THE SIGNING OF THE CONTRACT 10. WILL BE CONSIDERED AS IMPLICITLY DENOTING THAT THE CONTRACTOR HAS A THOROUGH COMPREHENSION OF 114E FULL INTENT 11. AND SCOPE OF THE WORKING DRAWINGS AND SPECIFICATIONS. CONTRACTOR SHALL VISIT THE SITE PRIOR TO BID AND VERIFY 12. THAT CONDITIONS ARE AS INDICATED. CONTRACTOR SHALL INCLUDE 13. IN HIS BID, COSTS REQUIRED TO MAKE NIS WORK MEET EXISTING CONDITIONS. WORK SHALL BE PERFORMED IN A WORKMANLIKE MANNER TO THE SATISFACTION OF THE ARCHITECT. 14. WORK, MATERIAL, AND EQUIPMENT SHALL CONFORM OT THE LATEST EDITIONS OF LOCAL STATE, AND NATIONAL CODES AND ORDINANCES 15. PROVIDE PERMITS AND INSPECTIONS REQUIRED. GUARANTEE THE INSTALLATION AGAINST DEFECTS IN MATERIALS AND 16. WORKMANSHIP WHICH MAY OCCUR UNDER USAGE FOR A PERIOD OF ONE YEAR AFTER OWNER'S ACCEPTANCE. DEFECTS SHALL BE PROMPTLY REMEDIED WITHOUT COST TO THE OWNER. 17. VERIFY EXACT LOCATION OF EQUIPMENT TO BE FURNISHED BY OTHERS PRIOR TO ROUGH -IN. SYSTEMS SHALL BE TESTED FOR PROPER OPERATION. IF TESTS 18. SHOW THAT WORK I5 DEFECTIVE, CONTRACTOR SHALL MAKE CORRECTIONS NECESSARY AT NO COST TO THE OWNER. CONTRACTOR SHALL BE REPSONSIBLE FOR REPLACING EQUIPMENT 19. WHICH I5 DAMAGED DUE TO INCORRECT FIELD WIRING OR FACTORY WIRING IN EQUIPMENT PROVIDED BY THIS CONTRACTOR. 1. CONTRACTOR'S FAILURE TO ORDER OR RELEASE ORDER FOR MATERIALS AND /OR EQUIPMENT WILL NO BE ACCEPTED AS A REASON • TO SUBSTITUTE ALTERNATE MATERIALS, EQUIPMENT, OR INSTALLATION METHODS. SYSTEMS SHALL BE COMPLETE, OPERABLE AND READY FOR CONTINUOUS OPERATION. LIGHTS, SWITCHES, RECEPTACLES, MOTORS, ETC, SHALL BE CONNECTED AND OPERABLE. • PANEL DIRECTORIES SHALL BE REMOVABLE. SUBMIT PROPOSED SCHEDULE OF DIRECTORIES TO OWNER FOR APPOVAL. ROOM NAMES AND NUMBERS SHALL BE AS DIRECTED BY OWNER. DIRECTORIES SHALL BE TYPED AND INSTALLED UNDER CLEAR PLASTIC COVERS. PROVIDE SELF ADHESIVE INDENTIFICATION INSIDE COVER OF EACH • FUSIBLE SWITCH, INDICATING SIZE AND TYPE OF FUSES PROVIDED. ALL WIRING SHALL BE INSTALLED IN LISTED METALLIC RACEWAYS. RACEWAYS IN SLAB -ON -GRADE OR BELOW GRADE SHALL BE SCHEDULE 40 PVC. JACKET OR PREMT FITTINGS SHALL BE MALLEABLE IRON OR STEEL. CONNECTORS SHALL BE INSULATED THROAT TYPE. ALL BRANCH CIRCUIT AND FEEDER CONDUITS SHALL HAVE A CODE SIZED COPPER GROUNDING CONDUCTOR. INCREASE CONDUIT SIZE AS REQUIRED. FIRE ALARM, SOUND, TELEPHONE, DATA, AND SIMILAR SYSTEMS CONDUITS LARGER THAN 1° SHALL HAVE LONG RADIUS SWEEPS (12 TIMES THE DIAMETER). ALL ELECTRICAL SYSTEMS COMPONENTS SI4ALL BE LISTED OR LABELED BY UL. OR OTHER RECOGNIZED TESTING FACILITY. LIGHTING: RECESSED LIGHT FIXTURES INSTALLED IN GYP BOARD OR PLASTER CEILINGS SHALL HAVE PLASTER FRAMES INSTALLED PRIOR TO CEILING MATERIAL RECESSED FIXTURES INSTALLED INDOORS SI4ALL BE THERMALLY PROTECTED. VERIFY TYPE OF CEILING CONSTRUCTION FOR PROPER MOUNTING OF ALL RECESSED LIGHT FIXTURES. INSTALLATION OF LIGHT FIXTURES SHALL COMPLY WITH ALL INTERNATIONAL BUILDING CODE REQUIREMENTS. MOTORS= VERIFY LOCATION OF ALL MOTORS AND EQUIPMENT BEFORE ROUGH -IN. SEE DIVISION 15 DRAWINGS FOR LOCATION OF MECHANICAL EQUIPMENT. PROVIDE SERVICE TO AND CONNECT EQUIPMENT AS REQUIRED. FIRE ALARM: CONTRACTOR SHALL PROVIDE DEVICES, CONDUIT, WIRES, AND CABLE AS DIRECTED BY EQUIPMENT MANUFACTURER. MATEIRALS, EQUIPMENT, AND WORKMANSHIP SHALL MEET PREVAILING CODES. TI4E SYSTEM SHALL BE COMPLETE AND OPERABLE IN EVERY RESPECT. THE LANDLORDS FIRE ALARM CONTRACTOR SHALL PERFORM ALL SYSTEMS CONNECTIONS AND DEVICE INSTALLATION WORK AT TENANTS EXPENSE. COMMUNICATIONS: SOUND SYSTEM. CONTRACTOR SHALL PROVIDE ALL CONDUIT, J -BOXES FOR SOUND SYSTEM COMPLETE RACEWAY SYSTEM. CONDUIT SHALL BE A MINIMUM OF 3/4' UNLESS NOTED. SOUND SYSTEM CONTRACTOR SHALL FURNISH AND INSTALL SPEAKER WIRE, VOLUME CONTROLS, MICROPHONES, AMPLIFIERS, SPUTTERS, ETC. ■■■ MIMI MEM RECESSED FLOURESCENT LIGHT FIXTURE 1- - - -1 FLUORESCENT STRIP LIGHT FIXTURE LIGHT TRACK a WALL MOUNTED LIGHT FIXTURE /< 2x4 RECESSED FLOURESCENT FIXTURE EMERGENCY WALL LIGHTING UNIT WITH BATTERY PACK DUPLEX CONVENIENCE OUTLET • +16' A.F.F. U.N.O. d h DUPLEX CONVENIENCE OUTLET, SPLIT WIRED, • +18' ▪ A.F.F. U.N.O. DEDICATED DUPLEX CONVENIENCE OUTLET • +18° A.F.F. U.N.O. DUPLEX CONVENIENCE OUTLET • +42° A.F.F. U.N.O. FOURPLEX RECEPTACLE FLOOR OUTLET, HUBELL #SF3925 BRASS OR APPROVED EQUAL SPECIAL OUTLET, VERIFY NEMA CONFIGURATION WITH EQUIPMENT JUNCTION BOX, IN ACCESSIBLE LOCATION JUNCTION BOX IN ACCESSIBLE LOCATION WITH FLEXIBLE CONDUIT CONNECTION TO LIGHTING FIXTURE OR EQUIPMENT AS NOTED TELEPHONE OUTLET (WITH 3/4° C. STUBBED ABOVE o CEILING U.N.O.) • +18' A.F.F. 0 TELEPHONE OUTLET, FLOOR MOUNTED (STUB 3/4' E.G. ABOVE ACCESSIBLE CEILING INTO ACCESSIBLE CEILING SPACE. INDICATES CIRCUIT IN CONDUIT CONCEALED IN OR UNDER FLOOR CONSTRUCTION OR BELOW GRADE INDICATES CIRCUIT IN CONDUIT CONCEALED IN WALL OR CEILING SPACE INDICATES HOMERUN TO PANELBOARD OR AS NOTED. HASH MARKS INDICATE NUMBER OF CONDUCTORS. NO HASH MARKS INDICATES 2 *12 AWG, 1 *12 BOND, 1/2° CONDUIT PANELBOARD DISCONNECT SWITCH - SIZE AND FUSES PER MANUFACTURER'S RECOMMENDATIONS (WEATHER- PROOF WHERE OUTSIDE). od THERMOSTAT OUTLET, +46' A.F.F. WITH 45 BOX AND PLASTER RING. /0/ MOTOR - SIZE AS INDICATED IN DRAWINGS SINGLE POLE SWITCH N.P. RATED MANUAL MOTOR STARTER WITH THERMAL ri OVERLOAD PROTECTION. (WEATHERPROOF WHERE OUTSIDE) ® SMOKE DETECTOR (MATCH EXISTING) ® DUCT SMOKE DETECTOR (MATCH EXISTING) 17c .❑ A TIMECLOCK 'INTERMATIC, 174018. PUSH BUTTON BUZZER A.F.F. ABOVE FINISHED FLOOR A.D.A. AMERICAN WITH DISABILITIES ACT G. CONDUIT C/B CIRCUIT BREAKER E.C. EMPTY CONDUIT WITH PULL CORD. E.D.F. ELECTRICAL. DRINKING FOUNTAIN (VERIFY ROUGH -IN REQUIREMENTS) EF EXHAUST FAN F.B.O. FURNISHED SY OTHERS, INSTALLED BY ELECTRICAL CONTRACTOR GFI GROUND FAULT INTERRUPTER GFCI GROUND FAULT CIRCUIT- INTERRUPTER GND GROUND 1 50 ISOLATED IG ISOLATED GROUND NL NIGHT LIGHT REC RECEPTACLE S.E.S. SERVICE ENTRANCE SECTION T.M.B. TELEPHONE MOUNTING BOARD. 4'Wx8'Hx3/4'D PLYWOOD WITH *6 CU. GROUND WIRE TO APPROVED GROUND. T.T.C. TELEPHONE TERMINAL CABINET. 30'144x369-1t6'D 16 GA. WEATHERPROOF VW HINGED LOCKABLE COVER 5/6' PLYWOOD BACKBOARD, PROVIDE A #6 CU. GROUND WIRE TO APPROVED BUILDING GROUND. U . N.O. UNLESS NOTED OTHERWISE U/C UNDER COUNTER WI-I WATER NEATER WP WEATHERPROOF (RAINTIGHT) XFMR TRANSFORMER, ADA NOTES LIGHT SWITCHES, ELECTRICAL OUTLETS, THERMOSTATS AND OTHER ENVIRONMENTAL CONTROLS SHALL HAVE OPERABLE PARTS OF TI4E CONTROLS LOCATED NO NIGHER THAN 46' AND NO LOWER THAN 15° ABOVE THE FLOOR. IF 114E REACH I5 OVER AN OBSTRUCTION BETWEEN 20° AND 25' IN DEPTH, THE MAXIMUM HEIGHT I5 REDUCED TO 44' FOR FORWARD APPROACH OR 46° FOR SIDE APPROACH, PROVIDED THE OBSTRUCTION I5 NO MORE THAN 24' IN DEPTH. OBSTRUCTIONS SHALL NOT EXTEND MORE THAN 25° FROM THE WALL BENEATH A CONTROL. I. CONTRACTOR SHALL VISIT THE SITE AND FAMILIARIZE HIMSELF WITH THE EXISTING CONDITIONS UNDER WHICH HE I5 TO PERFORM His WORK. NO ALLOWANCE WILL BE MADE FOR FAILURE TO COMPLY. 2. INFORMATION SHOWN ON PLANS AS EXISTING SHALL BE FIELD VERIFIED BY ELECTRICAL CONTRACTOR. ANY DISCREPANCY SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER FOR CLARIFICATION PRIOR TO STARTING WORK. 3. ALL ELECTRICAL WORK SHALL BE DONE IN ACCORDANCE WITH THE LATEST ADOPTED NATIONAL ELECTRICAL CODES AND ALL APPLICABLE FEDERAL, STATE AND LOCAL. CODES AND ORDINANCES. 4. VERIFY EXACT LOCATION, MOUNTING HEIGHT AND ALL ELECTRICAL REQUIREMENTS OF ALL EQUIPMENT PROVIDED BY OTHERS INCLU- DING BUT NOT LIMITED TO HVAC, WATER HEATERS, GENERATORS, ETC. CONTRACTOR SHALL COMPARE NAMEPLATE RATINGS OF EQUIPMENT SUPPLIED 'WITH THE REQUIREMENTS NOTED 014 THESE DRAWINGS AND ADVISE ENGINEER OF ANY DISCREPANCY PRIOR TO ROUGH -IN AND WIRING OF EQUIPMENT. 5. ALL WIRING /CONDUCTORS SHALL BE COPPER, THHN/THWN OR XNNW INSULATED MINIMUM SIZE *12 INSTALLED IN METAL CONDUIT. MINIMUM CONDUIT SIZE TO BE 3/4 °. PROVIDE INSULATED COPPER BOND WIRE ON ALL RACEWAYS SIZED PER N.E.G. ART 250. 6. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATION OF LIGHTING FIXTURES. VERIFY CEILING TYPES AND PROVIDE NECESSARY MOUNTING HARDWARE TO ACCOMODATE LIGHT FIXTURES USED. PROVIDE SLOPE CEILING ADAPTERS WHERE REQUIRED. 7. ADDITIONAL EXIT SIGNS AND EMERGENCY LIGHTING MAY BE REQUIRED. ADDITIONAL. FIXTURES SHALL BE LOCATED AS DIRECTED BY THE LOCAL BUILDING INSPECTOR OR ARCHITECT. ELECTRICAL NOTE ONE DUPLEX RECEPTACLE CONNECTED TO DEDICATED, NON — SWITCHED CIRCUIT BREAKER. THE VOLTAGE BETWEEN GROUND AND NEUTRAL MUST BE BETWEEN 0.1 AND 0.5 VOLTS. MOUNT DUPLEX OUTLET WITHIN THREE FEET OF TI-IE UPPER LEFT NAND CORNER OR THE INSIDE OF TI-IE OPENING. THE OUTLET CAN MOUNT ON 7HE POST OR FLUSH ON THE SOFFIT. EQUIPMENT MOUNTING POWERPACK: WILL MOUNT ON LEFT HAND POST 'WITHIN 3 FEET OF TI-IE UPPER LEFT NAND SIDE OF THE OPENING ABOVE THE CEILING. TRANSMIT LOOP ANTENNA: THE ANTENNA WILL BE ROUTED THROUGH THE 14 IREMOLD (OR WITHIN WALL HOUSING SURROUNDING DOOR), UNDER THE SIGN IF POSSIBLE, THROUGH THE CONDUIT IN FLOOR MAKING A COMPLETE LOOP AROUND THE DOOR. A PIG TAIL CONNECTS THE POWER PACK TO 7NE RECEPTACLE OUTLET. ALL CABLE WILL BE CONCEALED IN WI REMOLD OR WITHIN TI-IE WALL. TURBO ANTENNAS: A TOTAL OF FOUR TURBO ANTENNAS WILL BE MOUNTED AROUND TI-IE DOOR. TWO ON THE LEFT AND TWO ON TI-IE RIGHT. THE LOWER ANTENNAS WILL BE 18 TO 24 INCHES AFF AND THE UPPER UNITS WILL BE 36 TO 48 INCHES AFF. ALL ANTENNAS WILL BE MOUNTED ON THE WIREMOLD INSTALLED FOR TI-IE TRANSMIT LOOP CABLE. ALL CONNECTING CABLE WILL BE CONCEALED IN THE TRANSMIT LOOP WIREMOLD. SCHEDULING INSTALL OF WG SECURITY SHOULD BE SCHEDULED WHEN THE ENTRY WAY I5 COMPLETED; ALL GLASS, FLOORING, METAL CLAD, AND DOORS INSTALLED, ROLL DOWN CAGE OPERATIONAL AND 5IGNAGE COMPLETED. SITE SHOULD BE ON PERMANENT POWER. SYSTEM CAN BE INSTALLED ON TEMPORARY POWER, HUT I5 NOT PREFERABLE. CONCEAL WITHIN WI REMOLD . SEE ARCHITECTURAL PLANS FOR DETAILS. DUPLEX OUTLET MOUNTED ON SOFFIT. (FIELD VERIFY) 18' AT 'V' FROM TENANT LEASE LINE. STUB UP L -37 STUB UP TOP VIEW QUADRUPLEX WG SECURITY DEDICATED, NON — SWITCHED RECEPTACLE. NEUTRAL TO GROUND READING MUST BE BETWEEN O.1V AND 0.5V. CEILING WG SECURITY CONTROLLER INSTALLED WITHIN 3' OF LEFTHAND DOORWAY COLUMN. NOTE: REFER TO MANUFACTURERS INSTRUCTIONS FOR SPECIFIC INSTALLATION REQUIREMENTS. L.L. COORDINATION NOTE: k> VERIFY WITH MALL ANAGEMENT ANY TRENCHING OR CUTTING LOCATIONS AND CONSTRUCTION REQUIREMENTS BEFORE PROCEEDING WITH WORK. FLOOR MOUNT WITHIN THREE FEET OF LEFT DOORWAY COLUMN. ENTRANCE 7TURE10 ANTENNAS MOUNTED ON W IREMOLD.< BOTTOM OF CONCRETE WIREMOLD TO MATCH STORE INTERIOR. E.G. TO INSTALL ANTENNA PER INSTALLATION INSTRUCTIONS. COORDINATE WITH ARCI- IITECTURAL DRAWINGS. MOUNT TURBO ANTENNAS ON log !REMOLD. (ONE OF FOUR SENSORS) c— TRANSMIT LOOP RUN IN WI REMOLD FRONT VIEW RUN TRANSMIT LOOP AROUND TI-IE ENTIRE DOORWAY, THROUGH VI !REMOLD AND IN CONDUIT IN FLOOR. 1' PVC CONDUIT INSIDE SLAB, STUBBED UP INTO DOORWAY WI REMOLD . — FLOOR tW0523 NOT MORE THAN 2' OF CONCRETE OR ANY METAL ABOVE CONDUIT BOTTOM OF CONCRETE SECTION RE INFORCEMENT MEANS IN CONCRETE REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC JUN 2 2011 City of Tukwila BUILDING DIVISION RECEIVED JUN 08 2011 PERMIT CENTER 530 PAc$un. COPYRIGHT NOTICE: These drawings and specifications are copyrighted and subject to copyright protection as an "architectural work" under sec. 102 of the copyright act, 17 u.S.C. As amended January 2003. The protection includes, without limitation, the overall form, arrangement and composition of spaces, and elements of the design. Under such protection, unauthorized use of these drawings and specifications may result in cessation of construction, building seizure, and /or monetary liability. Q O u) 5, L,,-; 00 co mi � N U it � O (1) U) REVISION NUMBER AND DATE ANDREW C. PANOPIO P.E. 4115 N. 15TH AVE PHOENIX, AZ. 85013 (802) 285 -1558 PROJECT NO. 1 1.09 6 DATE: 5/24/2011 SHEET: SCALE: 1/4 -t' -0' E400 DRAWN BY: STAFF PROJECT No.: PSN -10 -016 AUDIO \STALLATIO \OT ES: DETAIL 3 1. I\STALL WALL vOU\TE3 BOSF SPEA<ER. SEE DETAIL 4. 7, PLACE E31 SPEA<ER I\ COW CO\\ECTOR J—BOX. SEE 3 3. \STALL WALL VOU\TED EC), TO DMX HEADEND VA12 STAC V\ \ FRO\ ETAIL 3.5 PVE\T RAC STOC< ROOV. SEE DETAIL 1. 4, I\STALL RCX—J2\ AT SWITC EIG I\STALLE3 J BOX. SEE DETAIL 2. 5, \STALL CC64 AT SW TCH HEIGHT 5 GA\G J—BOX. SEE DETAIL 2. 6. USE ALL VEANS \KCESSARY TO E CABLES ARE VISIBLE. 7, SOLDER T 1 SPEA<ER W THE BAC< OF T E THE WIRES TO T <5 T OF < I \ T I\ EC 1-C \STALL SUR RES TO CON \L4 PLATE. 30 \ CO\\ECTORS. \ 0 \ECTORS 0\ OT CRIvP 3 13 W a M Ma DS16F co TAP AT m Boa osi 13— = e T TIT T T T T T T 11 11 11 11 11 11 11 11 DETAIL 4 • EQ EC:2 DETAIL 3.5 T T 11 11 P1 9: T T T T T 11 11 11 11 11 11 -11 11 T 11 11 11 11 T T 1 II DETAIL 3.5 P1 alga T T T T 11 11 11 11 11 • TT T 11 11 DETAIL 4 14/2 1 14/2 TO DMX TO DMX et. 14 2 HEADEND =mime HEADEND =MP= * TO DMX HEADEND • DETAIL 5 (TYP) = = DETAIL 5 (TYP) = = TO DMX HEADEND DETAIL 3 110- €1? 14/2 TO DMX HEADEND 14/2 TO DMX HEADEND 1 14/2 TO DMX HEADE\D PI ETAIL 1 4/2 ITO DETAIL 4 Afga DETAIL 3.5 II II II II II II 1 1 II II II II II 1 11111 1 1 1 1 1 1 1 5 II II II II II II DETAIL 3 1. 1 .1 1 P1 1.1 II II II II II II .1111 DETAIL 4 II II II II II II 1111 0 DETAIL 3 Weight of fully equipped rack is approx. 225 lbs. Support wall according to local codes. Use back board. Refer to rack's installation instructions. MOWN. Rack Backboard BOTTOM OF RACK TO BE 7'-6" AFF. NOTE: G.C. TO VERIFY LOCATION WITH ARCHITECTURAL DRAWINGS. 3 25.40 Rack opening (12.5" IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII ITAIL 1 3 x 12.5") BO .00 0 12.5 0 0 0 0 At. 0 tfi (2) 20 Amp dedicated circuits in a quad box. Installed by EC. (2) 4"x4" J—Box for Audio Cables. Installed by EC. (1) Single gang J—box for telecom plate/jack. Installed by EC. VX HEADE\ D EQUIP E\T 5—gang J—box with Bose CC64 Controller DI- TA L Singe RCX—J2 co ma. gang J—box Rough In Pcn with DJ plate co\TRoL/ \OTE: Refer to c Rack Backboard etail A/A704 for control plate location. \PJT PLA 054," 1 Z Single—gcng 31 J—box wits sg NL4 connector plcte. A ,5 \ 4 PLA Single—gcng J—box with \L4 connector plate centerec between stcncarcs. See cetcils 5 & 6 on A503 per subs locatec in back of pilasters DI-TA 5 \L4 PLAT- TERMINATE CONNECTING CABLE USING TERMINAL STRIP. MAKE SURE TO RUN CABLE TIGHTLY SECURED AT BACK POINT OF STACKS. WMB2—MA12EX PITCH LOCK UPPER BRACKET. PITCH STACKS 3° TO so. 3/4" CONDUIT BOSE SPEAKER TO BE INSTALLED USING APPROVED MOUNTING METHODS. SEE EQUIPMENT MANUAL FOR FURTHER DETAILS. WMB— V1Al2EX BI—PIVOT BRACKET CONDUIT STUBBED TO SGL. GANG J—BOX SUPPLIED BY G.C. MOUNT J—BOX AT 1'-8" AFF. 1 22/SH CAT5 Ec2 A 1 1 1 DETAIL 1 I BOSE CC64 DETAIL 2 IPOD INPUT TAL 4 BOSH VA17 STA am, KS e SYMBOL DESCRIPTION BOSE MA12 STACKS SPEAKER. 6 BOSE 81 BASS MODULE. I( TAP AT 8 OHM 0 BOSE DS16F BOSE FREESPACE DS 16F FLUSH MOUNT LOUDSPEAKER. DMX WALL MOUNT EQUIPVENT RACK. > < BOSE CC64 CONTROL CENTER. C BOSE CC64 1 RDL RCX-J2\ PLATE. J IPOD INPUT NL4 NL4 DvX NL4 SPEAKON PLATE. P P1 1 1 ol6/2 CABLE TYPE NUMBER OF CABLE RUN t023 REVIEWED .FOR COMPLIANCE WITH NFPA70- NEC JUN 2 1 2011 City of Tukwila BUILDING DIVISION RECEIVED JUN 08 2011 PERMIT CENTER 530 plicsun• COPYRIGHT NOTICE: These drawings and specifications are copyrighted and subject to copyright protection as an "architectural work" under sec. 102 of the copyright act, 17 u.S.C. As amended January 2003. The protection includes, without limitation, the overall form, arrangement and composition of spaces, and elements of the design. Under such protection, unauthorized use of these drawings and specifications may result in cessation of construction, building seizure, and/or monetary liability. • • FOR REFERENCE ONLY DATE: SCALE: 5/24/2011 N.T.S. DRAWN HY: ZAK PROJECT No.: SWEET: E600 PSN-10-016 TO AV EQUIPMENT - TO AV EQUIPMENT — I` I I e TO AV EQUIPMENT - TO >u AV EQUIPMENT • _ SEE NOTE 5 I== — k = • _ _ • _ SEE NOTE 5 _ T T T T T T 11 fir T TT i Tom$ 1 T T TT T T TT T..... ....T T TT Tli TT T ...:: SEE NOTE 3 II II V II II II II II II II II II II -1 11 0 II II II II 11 II II II 1 II II II SEE NOTE 4 II II II L SEE NOTE 4 J SEE NOTE 3 0 0 0 0 0 0 0 0 O 0 O 0 O 0 O 0 0 0 0 0 0 0 O 0 O 0 O 0 O 0 0 0 0 I 0 0 0 0 0 0 0 0 0 0 0 0 0 O 0 O 0 O 0 O 0 O 1 0 O 0 O 0 0 0 O ' 0 0 O 0 O 0 O 0 O 0 O 0 SEE NOTE 3 II II II II II 1 1 1 1 1 0 r TO % EQUIPMENT< � 01 0 ® 0 0 0 0 1 0 I \ I SEE NOTE 4 NOTE 4 SEE NO II II II 1 II II II 0 II II II 0 II II II II II II III II II II II II II II II II II II II 1 II II II II 1 1 _._._.___.___.__ ._._.__._.__.... .._..._._.___....._.......... �.. ............ ... .... J_....... .. ....._...._.1. ,_._._..__...._ _.. _.__.._.._.1.._.__._.__._.._:11w O 0 O -0 O 0 SEE NOM 3 SYV BOL DESCRIPT O\ SI \GL- GA \G STA\ DARD DEPT- J —BOX WIT- PLASTI- R RI \G. '1 ❑ 2 4" SQJAR- JT L TY BOX FLS I VO \T I\ WALL AS \OTED. S \GLE GANG STA \DARD DEPTH J -BOX \STALL - D ABOVE 1 F \ I SH FD CF LI \ G. 3 4 F V1- GA\G J —BOX \STALLED AT SWI TC I -FIG T WI TI I 3/ " CONDJT TO I \TFRFACE BOX ABOVE F \ISH CE LI \G. 3/4" D AVET- R CO \D „IT. GC /EC LEGS\ D NOTES: 1. \STALL PLYWOOD BAC< BOARD TO SUPPORT AUDIO RACK. \STALL ( ) 2 411 SQUARE UTILITY BOX: FOR AUDIO CABLES AT- FIELD CO\ DU TS TER' I \ATED AT T- 1S LOCAT 0\ . \STALL (1) S \GLE -G J -BOX BELOA AUDIO BOXES A TI-I 3/4H CO \DU IT FRO' TELECOM' BOARD. \STALL (2) 120VAC 20 A~'P DEDICATED CIRCUITS \ A QUAD OUTLET. REFER TO D~'X- AV1.01 FOR DETAIL. 2. I \STALL A 5-GA\G J -BOX AT SA ITC- A T- A SI \GLE GA\G J-BOX AT SA TC- -E G -T 211 TO T -E RIG -T. USE 3/411 CO \DU T TO CO \ \ECT THE TAO J -BOXES A\D T -E\ A SI \GLE 3/4' -0'': RU\ TO T -E EQUIPVE\T RACK. REFER TO D'X- AV1.01 FOR DETAIL. 3. AALL 'OU \TED SGL. GA\G J -BOX AT 11 -811 A.F.F. A IT- DAISY C1-IAI \ ED CO\ D., IT AS S1-IOA \ 0\ T-I S LAYOUT. REFER TO D~'X- AV1.01 FOR DE-AIL. . AALL "OU \ ®ED SI \GLE GA\G J -BOX AT 811 A.F.F. AIT1 -I DAISY C-1AI \ED CO\DUIT AS SI -IOA\ 0\ T -1S LAYOUT. REFER TO D1'X- AV1.01 FOR DETAIL. 5. SGL. GA \G J -BOX ~'OU \TED ABOVE FINIS- CEILING. GE\ ERAL \ OTI- S: — GC /EC RESPO\ SIBLE FOR PROVI DI \ G AND I \ STALLI\ G ALL CO\ - LECTRICAL OJTLETS, \ISTRJT, A \D PLYWOOD BACKI \G. — ALL LTIL TY BOXFS SI TALL BI- PROVIDED WITH STEEL COVERS. ALL CO \DJIT 3IAV T- RS SHALL BF 3/4” „ \LFSS OT1 11- RWISF S P C F TO BE PROVIDFD WITII PJLL STRI \GS. - ALL EXPOSED J —BOXES A\ D CO 1 DJ T TO BF PAI \ TI- D WI I I TF. DT, J- BOX1- S, REVIEWED FOR COMPLIANCE WITH NFPA70 - NEC JUN 2 2011 City of Tukwila 1 BUILDING DIVISION D. ALL CO\ D „ I T RECEIVED JUN 0 8 2011 PERMIT CENTER 530 Pncsun. • COPYRIGHT NOTICE: These drawings and specifications are copyrighted and subject to copyright protection as an "architectural work" under sec. 102 of the copyright act, 17 u.S.C. As amended January 2003. The protection includes, without limitation, the overall form, arrangement and composition of spaces, and elements of the design. Under such protection, unauthorized use of these drawings and specifications may result in cessation of construction, building seizure, and /or monetary liability. c Q Q 0 u) L- (1) 00 -1.1 N U � C m5 CU O CD- • 0 I 0) REMENTS FOR REFERENCE ONLY DATE: SCALE:: 5/24/2011 N.T.S. DRA1MI EBY: ZAK rieotracirrO10. SWEET: E601 PSN -10 -016