Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit EL11-0563 - WESTFIELD SOUTHCENTER MALL - ICING
ICING 1003 SOUTHCENTER MALL EL1 1 -0563 City oftukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: / /www.TukwilaWA.gov ELECTRICAL PERMIT Parcel No.: 9202470010 Address: 1003 SOUTHCENTER MALL TUKW Project Name: ICING Permit Number: EL11 -0563 Issue Date: 08/15/2011 Permit Expires On: 02/11/2012 Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA Contact Person: Name: AMY SHYMANSKI Address: 319 ELAINES CT , DODGEVILLE WI Contractor: Name: OTI SERVICES INC Address: PO BOX 982 , MCKENNA WA Contractor License No: OTISESI940Q 1 Phone: 608 - 319 -2096 X8 Phone: 360- 458 -2927 Expiration Date: 11/21/2012 DESCRIPTION OF WORK: ELECTRICAL FOR INTERIOR TENANT IMPROVEMENT Value of Electrical: NRES: $18,000.00 RES: $0.00 Fees Collected: Type of Fire Protection: UNKNOWN National Electrical Code Edition: Electrical service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: $502.63 2008 (A) W Date: 8— LC— (1 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the perform ap of rk.I am authorized to sign and obtain this electrical permit. el'<i-t Signature: Print Name: //a it "el Q�� 47' Date: 2- /S -// This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/10 EL11 -0563 Printed: 08 -15 -2011 PERMIT CONDITIONS • Permit No. EL11 -0563 * *ELECTRICAL ** 1: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 2: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 3: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296-46B WAC. 4: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 5: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 6: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. doc: EL -4/10 E L 11 -0563 Printed: 08 -15 -2011 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 hltal/www.ci.tukwila.wa.us Electrical Permit No: E L 4 (.•-- 0 S'(p 3 Project No. (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans tnust be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print ** SITE LOCATION (003 L King Co Assessor's Tax No.: Site Addrcss: -t ' SO>.W`?Cto -ilf'1 1414,ee Suite Number: y37--- Floor: Tenant Name: Property Owners Name: 1444 1i6-<o( got p . Mailing Address: / /(t p( WI/Silted f(✓G1. //W'G New Tenant: Yes ❑..No Lorry City CA— State joa ZS- Zip CONTACT PERSON - Who do we contact when your permit Is ready to be issued Name: Mailing Address 3q a, . e-0 a - E -Mail Address: Amy ®S11'es° 14 Day Telephone: led F.31'9. 2094 X J ek ;l4 (Nl S3J7.3 cit Statc Lip Fax Number: It O?.St 9. 20 (t ELECTRICAL CONTRACTOR INFORMATION -D Company Name: Mailing Addrcss: ciq Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: State Zip Valuation of Project (contractor's bid price): S / f /efee Scope of Work (please provide detailed information): k1"(1et/O1- 12hol1. t I t-O�•te et Pay Will service be altered? XI 1'cs Type of Use: /-G Type of work: ❑ New ❑ Addition ❑ Low Voltage ❑ Generator Property Served bv: ❑ Puget Sound Energy ❑ Seattle City Light ❑ No Adding more than 50 amps? ❑ Yes p( No ❑ Service Change Remodel ❑ Tenant Improvement ❑ Fire Alann ❑ Telecommunication ❑ Temporary Service I I. ApptrcAirm. torms.,%pplicatioru On I.mc Zola AprLcnu,n.n•:OtD- Lkotrcal remit Apph..tiwn.dra bb Pagc 1 oft r RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings (including an attached garage) ❑ Garages, pools. spas and outbuildings ❑ Low voltage systems (alarm. furnace thermostat) S152.85 S81.90 ea 559.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration S81.90 (no added/altered circuits) ❑ Service change with added/altered circuits number of added circuits ❑ Circuits added/altered without service change (up to 5 circuits) ❑ Circuits added /altered without service change 554,60 (6 or more circuits) S7.65 ea ❑ Meter /mast repair 568.25 ❑ Low voltage systems S59.85 (alarm, furnace thermostat) S8I.90 511.55 ea S54,60 MULTI-FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) S63.00 ❑ Temporary service (generator) 578.75 ❑ Manufactured /mobile horns service S34.II1 (excluding garage or outbuilding) ❑ Carnivals 578.75 Number of concessions S 10.50 ea PERMIT APPLICATION NOTES - Value of Construction - In all cases. a value of construction amount should he entered by the.applicant. This figure will be revieoed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of flan Review - Applications for which no permit is issued within 180 days following the dale of application shall expire by limitation. The Building Official may gran) one extension of time for an additional period not to exceed 90 days. The extension shall he requested in writing and justifiable cause demonstrated. 1 f 1F.REBY CERTIFY TI IAT I HAVE READ AND EXAMINED TIIIS APPLICATION AND KNOW TI Ili SAME TO BE TRUE UNDER PENALTY OF PERJURY IIY TILE LAWS OF TI IE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR TIIIS PERMIT. R(1fLDfN . OWNER OR ELECTRICAL CONTRACTOR: Signature: Date: 7z7/4 Wi Print Name: ` ' if J� y �lrk,e Day Telephone: &C.3/9.2096k r DageOtt Cih Mailing Address: S3 Slalc Date Application Accepted: Date Application Expires: f Staff Initials: 11 .%rrl cabrm l nm,.- r, I....,.., 1,n 1 ,ne 2510 :n10 r lrc,nul r,,,,ut h4 Page of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov RECEIPT Parcel No.: 9202470010 Permit Number: EL11 -0563 Address: 1003 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 06/28/2011 Applicant: ICING Issue Date: Receipt No.: R11-01768 Payment Amount: $402.10 Initials: WER Payment Date: 08/15/2011 02:35 PM User ID: 1655 Balance: $0.00 Payee: MARK BEDNAR TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 050789 ACCOUNT ITEM LIST: Description 402.10 Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.00 402.10 Total: $402.10 doc: Receiot -06 Printed: 08 -15 -2011 • • SET RECEIPT RECEIPT NO: R11 -01319 Initials: WER Payment Date: 06/28/2011 User ID: 1655 Total Payment: 1,366.90 Payee: STATE PERMITS INC SET ID: 062811 SET NAME: ICING SET TRANSACTIONS: Set Member Amount D11 -199 EL11 -0563 M11 -086 PG11 -088 TOTAL: 1,165.87 100.53 66.11 34.39 1,165.87 TRANSACTION LIST: Type Method Description Amount Payment Check 10458 1,366.90 TOTAL: 1,366.90 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES 000.345.832.00.0 PLAN CHECK - NONRES 000.345.830 TOTAL: 100.53 1,266.37 1,366.90 INSPECTION NO: INSPECTION RECORD Retain a copy with permit PERMIT N • .CITY OF' TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 IL. (206) 431 -367 Permit Inspection Request Line (206) 431 -2451 Project: i Type of Inspection: 440 v Address: 003- 11 Date Called: Special Instructions: IV j0 .'o0 4L•0w- Date Wanted:. /© i f 6—; p.m. Requester: Phone No: i-• • 4 Approved per.applicable codes. Corrections required prior to approval. COMMENTS: r cok9Acnoiti, t ';\//11- Inspector: 0\ ❑ REINSPECTION .FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Date: /opt( 1 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION • 6300 Southcenter Blvd., #100, Tukwila. WA 98188 vt. (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 INSPECTION RECORD Retain a copy with permit PERMIT NO. Project: te.4 Type of Inspection: ;r ©O Address: 1003 Date Called: Special Instructions: Date Wanted:. /o Vmy 7 p.m. Requester: Phone No: JApproved per applicable codes. Corrections required prior to approval. COMMENTS: ' fAiAN kJ At IV SteiR,t ItJakl re e� DASif- 3 PPMr(Z) Fa`) • C ►pa t1c 5 'P r Its.s GA u41+r 3 f fsif IC.- 1lnspector: Attkr\ • REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Date: /00111•. • a Y; • INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF' TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 ft (206) 431 -367 Permit Inspection Request Line (206) 431 -2451 Project: 0 • +] y\ Type of Inspection: �Dv Address: - -- 1003 ti's Date Called: Special Instructions: • • Z ,60 p.,N . Date Wanted:. 9 /4 p.m Requester: . Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: r - --ir6 Occe/Pi (7 4' (orit4): ".. c Quiff Acc Atielt Ate ► R .k /51/rPou- . r 04 P\c r 1 4 1 7 i trA 1�sA 30" l`i...� • k `z. cf 4 i Dn ) kr t • ;'iAP two-. t4fa elgtor d v.0,4. T E tfMa: witar ROD w'& (JD REINSPECTION FEE REQUIRED. Prior to next inspectiorS. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. •t ._o.. ._ -- INSPECTION RECORD ail-0543 Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: 1 c 1c Type of Inspection: 7003 Address: ►00 ��✓ T Date Called: I Special Instructio s: • v Date Wanted:. 7/4 a. Requester: Phone No: Approved per applicable codes. a Corrections required prior to approval. COMMENTS: Zdt, a i,J Pn iA Inspector: Date: • REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. I INSPECTION NO. INSPECTION RECORD rt' 1r , Retain a copy with permit U t0 PERMIT NO. CITY OF- TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 pri. (206) 431 -367 Permit Inspection Request Line (206) 431 -2451 Project: I /t isit\ Type of Inspection: Date Called: 7003/7431 1 Address: / 003 /_,Vi Special Instructions: Date Wanted:. Y. r Requester: Phone No: Approved per applicable codes. ElCorrections required prior to approval. COMMENTS: - 70O 3 AU/ i1 5; '04-0L ),3 r) 700/ V- PK CoAlpin Inspector: J'7 'Date: aft t i ❑ REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 2009 Seattle Energy Code Compliance Form for Nonresidential and Multifamily Residential Project Summary 2009 Seattle Energy Code Compliance Fo • r Nonresidential and Multifamily Residential PRJ -SUM Revised December 2010 Project Info Project Address Icing Date 6/24/2011 Westfield Southcenter Shopping Center For Building Department Use Seattle, WA Applicant Name: Don Penn Consulting Engineers ApplicantAddress: 635 Westport Parkway, Suite 300 Applicant Phone: Grapevine, TX 76051 HEVIEWED FOh COMPLIANCE WITH NFPA 70 - NEC JUL O'72011 City of .Tukwila BUILDING DIVISIO(' gL 11 -051v3 RECEIVED JUN 28 2011 PERMIT CENTER 0 Prescriptive 0 Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans cuu, oeauIe cnergy Lucie Lompnance corm tor Nonresidential and Multifamily Residential Interior Lighting Summary 2009 Seattle Energy Code Compliance Forms for idential and Multifamily Residential Project Info Project Address Icing Date Revised December 2010 6/24/2011 Westfield Southcenter Shopping Center Seattle, WA Applicant Name: Don Penn Consulting Engineers Applicant Address: 635 Westport Parkway, Suite 300 Applicant Phone: Grapevine, TX 76051 For Building Department Use Project Description ❑ New Building ❑ Addition 0 Alteration ❑ Plans Included Refer to SEC Section 1513 for controls and commissioning requirements. Compliance Option Alteration Excep (check appro. a - :', :. _ 4' 2.3) ^ • "' 0 ii No hanges are being made to the lighting and the space use has not changed °Less than ((60%)) 20% of the fixtures or of the lamps plus ballasts alone are altered, added, or replaced ((new)), installed wattage not increased, & the space use has not changed. Retail Sales Area Maximum Allowed Lighting Wattage (Interior) Location (floor plan /room #) Occupancy Description Allowed Watts per ft2'" Gross Interior Area in ft2 Allowed x Area Sales Area Retail Sales Area 1.33 965 1283 Retail Merchandise Display 1.50 1000 1500 B - Recessed Metal Halide Wall Washer Toilet Toilet Room 0.80 63 50 Stock Room Storage 0.50 111 56 ** From Table 15 -1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts 2889 Proposed Lighting Wattage (Interior Location (floor plan /room #) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Sales Area A - Recessed Compact Fluorescent 3 32 96 B - Recessed Metal Halide Wall Washer 15 39 585 C - Recessed Metal Halide Adjustable Accent 10 20 200 C2 - (2) Lamp Recessed Metal Halide Adjustable Accent 7 40 280 C3 - (3) Lamp Recessed Metal Halide Adjustable Accent 1 60 60 A - Display Window (exempt) 2 C2 - Display Window (exempt) 5 D - Track (via current limiting panel) 1 120 120 F -22 - 14W T5 Strip Light 1 14 14 F -34 - 21W T5 Strip Light 4 21 84 F -46 - 28W T5 Strip Light 3 28 84 F -58 - 35W T5 Strip Light 10 35 350 G - Decorative Chandelier (via current limiting panel) 4 120 480 L - Decorative Chandelier (via current limiting panel) 3 120 360 Stock Room R - 4' -0" Strip Light 1 64 64 .!.:J/# i i 1 1 1 Toilet J - 4'-0" Strip Light ( 4L ) 4 •"=:. i 6 1 m 64 64 Total Proposed Watts may not exceed Total Allowed Watts for Ulterior Total Pioposed Watts 2841 Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T -8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts /Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For line voltage track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or the wattage 2009 Seattle Energy Code Compliance Form for Nonresidential and Multifamily Residential ot current limiting devices or ot the transtormer. For low voltage track lighting list the transtormer rated wattage. 3. List all fixtures. For exempt lighting, notation and exception number, and leave Watts /Fixtu nk. Parking Garage Liahtint? - Ma' mum Allowed Wattage Location Occupancy Description Allowed Watts /ft2 Gross Area (ft2) Watts Allowed arlcing G=arage Lighting - Proposed Wattage Location Fixture Description # of Fixtures Watts /Fixture Watts Proposed The 2009 SEC Section 1510 specifies that parking garage lighting cannot be traded with other interior Total Proposed Watts 2009 Seattle Energy Code Compliance Forms for idential and Multifamily Residential LTG -INT Revised December 2010 Prescriptive Spaces Occupancy: 0 Warehouse or Parking Garage �0 Other I Qualification Checklist Note: If occupancy type is "Other" and fixture answer is checked, the number of fixtures in the space is not limited by Code. Clearly indicate these spaces on plans. If not qualified, do LPA Calculations. Lighting Fixtures: (Section 1521) Check if 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted. 1. Fluorescent fixtures a) with 1 lamp ) ((2s)), b) fitted with 5 to 60 watt T -1, T -2, T -4, T -5, T -8, or CFL lamps, and c) hard -wired electronic dimming ballasts and automatic dimming control for all lamps in all zones. Screw -in CFL fixtures, tracking lighting, bare lamp strip and industrial fixtures do not qualify. 2. Metal Halide with a) reflector b) ceramic MH lamps < =150w c) electronic ballasts 3. LED lights. -1 Unit Lighting Power Allowance (LPA Use' LPA2 (W /ft2) Use' LPA2 (W /ft2) Automotive facility and aircraft maintenance 0,82 ((gam)) Office buildings, office/administrative areas in facilities of other use types (including but not limited to schools, hospitals, 0.90 ((094)) Convention center 1.08 ((440)) Parking garages 0.20 Courthouse 1.05 ((440)) Penitentiary and other Group 1 -3 Occupancies 0.90 Cafeterias, fast food establishments5, racta■ trantc/hnrc5 0.99 ((4-20)) Police and fire stations 0.90 Dormitory 0.61 ((0.85)) Post office 0.87 ((4-:90)) Dweling Units 1.00 Retail10, retail banking, mall concourses, wholesale stores (pallet rack shelvjno) 1.33 Exercise center 0.88 ((0 }) School buildings (Group E Occupancy only), school classrooms, day care centers 0.99 ((1,80)) Gymnasia, assembly spaces 0.95 Theater, motion picture 0.83 ((09)) Health care clinic 0.87 ((1:09)) Theater, performing arts 1.25 Hospital, pharmacies, nursing homes, and other 1.20 Transportation 0,77 860 (( )) Group 1 -1 and 1 -2 Occupancies Hotel/motel 1.00 Warehouses 0.50 Laboratory spaces (all spaces not classified "laboratory" shall meet office and other appropriate 1.62 Workshops 1.20 Laundries 1.20 Libraries5 1.18 ((4 -20)) Plans Submitted for Common Areas Only Manufacturing facility 1.11 ((1 -20)) Main floor building lobbies3 (except mall concourses) 1.10 Museum 1.00 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.80 Footnotes for Table 15 -1 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by 2% per foot of ceiling height above 20 feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by 2% per foot of ceiling height above 12 feet. 4) Reserved. 5) Watts per square foot of room may be increased by 2% per foot of ceiling height above 9 feet. 6) Reserved. 7) Reserved. 8) Reserved. 9) Reserved. 10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three - quarter- height partitions (transparent or opaque) and lighting for free - standing display where the lighting moves with the display are exempt. An additional lighting power allowance is allowed for merchandise display luminaires installed in retail sales areas that are specifically designed and directed to highlight merchandise. The following additional wattages apply: i. 0.4 ((0:6)) watts per square foot of sales floor area not listed in items ii and iii below; ii. 0.9 ((44)) watts per square foot of furniture, clothing, cosmetics or artwork floor area; or iii. 1.5 ((2,b)) watts per square foot of jewelry, crystal or china floor area. The specified floor area for items i, ii, or iii above, and the adjoining circulation paths shall be identified and specified on building plans. Calculate the additional power allowance by multiplying the above LPDs by the sales floor area for each department excluding major circulation paths. The total additional lighting power allowance is the sum of allowances for sales categories I, ii, or iii plus an additional 1,000 watts for each separate tenant larger than 250 square feet in area. The additional wattage is allowed only if the merchandise display luminaires comply with all of the following: (a) Located on ceiling- mounted track or directly on or recessed into the ceiling itself (not on the wall). (b) Adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). This additional lighting power is allowed only if the lighting is actually installed and automatically controlled, separately from the general lighting, to be turned off during nonbusiness hours. This additional power shall be used only for the specified luminaires and shall not be used for any other purpose. This additional lighting power is allowed only if the lighting is actually installed. 11) Reserved 2009 Seattle EnergyCode Compliance Form for Nonresidential and Multifamily Residential 'Lighting, Motor, and;T~ansformer Permit Plans; "1;hecklist LTG -CHK 2009 Seattle Energy Code Compliance Forms for Isl. sidential and Multifamily Residential Revised December 2010 Project Address Icing (Date 6/24/2011 The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements in the 2009 Seattle Energy Code. Applicability (yes, no, n.a.) Code Section Component Information Required Location on Plans Building Dept. Notes _ LIGHTING CONTROLS (Section 1513) N.A. 1513.1 Local control /access Schedule with type, indicate locations Yes 1513.2 Area controls Maximum limit per switch E.2 N.A. 1513.3 Daylight zone control Schedule with type and features, indicate locations N.A. daylight zones Indicate primary zone and secondary zone separately N.A. parking garage Indicate daylight zone in parking garage N.A. vertical glazing Indicate vertical glazing on plans N.A. overhead glazing Indicate overhead glazing on plans Yes 1513.4 Display /exhib /special Indicate separate controls E.1 N.A. 1513.5 Exterior shut -off Schedule with type and features, indicate location N.A. (a) timer w /backup Indicate location N.A. (b) photocell. Indicate location N.A. 1513.6 Inter. auto shut -off Indicate location N.A. 1513.6.1 (a) occup. sensors Schedule with type and locations N.A. 1513.6.2 (b) auto. switches Schedule with type and features (back -up, override capability); Indicate size of zone on plans N.A. 1513.7 Hotel /motel controls Indicate location of room master controls N.A. 1513.8 Commissioning Indicate requirements for lighting controls commissioning EXIT SIGNS Section 1514) Yes 1514 Max. watts 'Indicate watts for each exit sign IE.2 I LIGHTING POWER ALLOWANCE (Section 1530 -1532) Yes 1531 Interior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture E.2 N.A. 1532 Exterior Lighting Summary Form Completed and attached. Schedule with fixture types, _ lamps, ballasts, watts per fixture MOTORS (Section 1511) N.A. I 1511 'Elec motor efficiency IMECH -MOT or Equipment Schedule with hp, rpm, efficiency I I TRANSFORMERS (Section 1540) N.A. I 1540 'Transformers 'Indicate size and efficiency 1 I If "no" is circled for any question, provide explanation: t PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL11 -0563 DATE: 06 -28 -11 PROJECT NAME: ICING SITE ADDRESS: 1003 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: PVC/ ' Bui ding uivision Public Works Fire Prevention Structural n Planning Division n Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 06 -30 -11 Not Applicable n Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUESITHURS ROUTING: Please Route 14 Structural Review Required REVIEWER'S INITIALS: No further Review Required n DATE: APPROVALS OR CORRECTIONS: DUE DATE: 07 -28-11 Approved n Approved with Conditions Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 Contractors or Tradespeople Pf ter Friendly Page • Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Business and Licensing Information Name OTI SERVICES INC UBI No. 602662140 Phone 3604582927 Status Active Address Po Box 982 License No. OTISESI940Q1 Suite /Apt. License Type Electrical Contractor City Mckenna Effective Date 11/21/2006 State WA Expiration Date 11/21/2012 Zip 98558 Suspend Date County Pierce Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company ther Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status OTISEED986K9 OTI SERVICES ELECT DIVISION Electrical Contractor General Unused 5/29/2002 5/29/2008 Expired Master Electrician INFORMATION License BEDNAMJ968MN Name BEDNAR, MARK J Status Active Business Owner Information Name Role Effective Date Expiration Date UNISEARCH INC Agent 11/21/2006 Bond Amount OTTWELL, RAMONA J President 11/21/2006 9806159 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 2 Lexon Ins Co 9806159 05/29/2011 Until Cancelled $4,000.0006/08/2011 1 INSCO INSURANCE SERVICES INC 857805C 11/20/2006 Until Cancelled 06/19/2011 $4,000.0011/21/2006 Assignment of Savings Information No records found for the previous 6 year period Insurance Information No records found for the previous 6 year period Summons /Complaint Information Summons and Complaints are not filed with the department for this contractor type Warrant Information Warrants are not filed with the department for this contractor type Infractions /Citations Information Infraction / Citation Date RCW Code Type Status Violation Amount EBOES00381 5/12/2009 19.28.101 RCW ELECTRICAL CITATION Satisfied $1,000.00 https: // fortress .wa.gov /lni/bbip/Print.aspx 08/15/2011 HONE / DATA FUTURE USE 11 11 11 1 1 11 1 1 11 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 11 A -2 VIA TIMECLOCK ELECTRICAL POWER PLAN SCALE: 1/4" = 1' -0" A -6 VIA TIMECLOCK F- 46 C2 10 0.- F-34 ELECTRICAL LIGHTING PLAN SCALE: 1/4" = 1' -0" REVIEWEU .FOA COMPLIANCE WITH NFPA70 - NEC JUL 07 2011 City of T ila BUILDING ' ISION NOTES: • CONDUIT INSTALLED INDOORS MAY BE GALVANIZED EMT, RIGID ALUMINUM, OR HEAVY WALL GALVANIZED RIGID STEEL • FLEXIBLE METAL CONDUIT SHALL BE USED ONLY FOR FINAL CONNECTION TO MOTORS AND OTHER ELECTRICAL EQUIPMENT, WHICH MAY GENERATE VIBRATION THROUGH THE CONDUIT SYSTEM. • FLEXIBLE METAL CONDUIT, WITH A MAXIMUM SIX -FEET LENGTH, SHALL BE USED FOR CONNECTION BETWEEN RECESSED LIGHTING FIXTURES AND OUTLET BOXES. • ALL LOW VOLTAGE, COMMUNICATION CABLES AND SIGNAL CABLES ROUTED THROUGH CEILING PLENUM SHALL BE PLENUM RATED OR BE IN CONDUIT. • CUTTING OF TEMPORARY OPENINGS AND PENETRATIONS IN THE REINFORCED CONCRETE STRUCTURAL FLOOR SLABS MUST CONFORM TO REQUIRED MALL DESIGN CRITERIA. ADDITIONALLY, THIS WORK MUST BE DONE BY THE LANDLORD'S APPROVED CONTRACTOR AT THE TENANT'S EXPENSE. • NO OPENINGS, INCLUDING PENETRATIONS, CORES OR CUTOUTS, IN THE CONCRETE FLOOR SLAB, WHETHER TEMPORARY OR PERMANENT, ARE ALLOWED WITHOUT THE PRIOR APPROVAL OF THE LANDLORD AND WRITTEN APPROVAL FORM THE LANDLORD STRUCTURAL ENGINEER. • TRENCHING OR GROOVING OF THE FLOOR SLAB IS STRICTLY PROHIBITED WITHOUT WRITTEN CONSENT FROM THE LL. • THE NUMBER OF NEW PENETRATIONS SHOULD BE KEPT TO A MINIMUM. UNLESS OTHERWISE DIRECTED, PENETRATIONS SHALL BE INSTALLED BY CORE DRILLING AND SHALL BE NO LARGER THAN 6 INCHES IN DIAMETER. STEREO RECEIVER & DMX UNIT NOTE: BECAUSE OF THE ELECTRICAL SERVICE AND SPEAKER WIRE CONDUIT REQUIRED BY THE STEREO RECEIVER AND DMX UNIT, THE HEAVY DUTY SHELF OR SHELVES SHOWN ON THIS PLAN, IS /ARE NOT TO BE RELOCATED WITH OUT THE PERMISSION OF THE ICING PROJECT MANAGER. NOTE: G.C. TO COORDINATE CONDUIT STUB -INS FOR CASH /WRAP. STUB -UPS ARE TO BE LOCATED WHERE THE ACCESS PANEL IS PROVIDED IN THE CASH / WRAP BASE. SEE OWNER'S SHOP DRAWINGS OF THE CASH / WRAP UNIT FOR FURTHER INFO. LIGHTING PLAN NOTES 0 1. EXIT LIGHT WITH SELF - CONTAINED BATTERY BACK -UP. CONNECT TO UNSWITCHED CIRCUIT. 2. EMERGENCY /EXIT LIGHT COMBO WITH SELF - CONTAINED BATTERY BACK -UP, CONNECT TO UNSWITCHED CIRCUIT. (MINIMUM 90 MINUTES ILLUMINATION UPON LOSS OF AC POWER) 3. NIGHT LIGHT (NL) /EMERGENCY LIGHT (EM). PROVIDE FIXTURE WITH EMERGENCY BATTERY BACK -UP. CONNECT TO UNSWITCHED CIRCUIT. 4. WIRE THROUGH CURRENT LIMITING PANEL. REFER TO SHEET E.2. SEPARATE PERMIT REQUIRED FOR Me'chanl0A1 a Electrical f'ItQnbing 14 Gas POI% BUILDIING DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. ACTS: Revisions will require a new plan submltt^i L_i,' may ih:!.'ude additional plan rr:•• °�.,.� V1 POWER PLAN NOTES 1. J -BOX FOR ILLUMINATED STOREFRONT SIGN. PROVIDE DISCONNECT MEANS AS REQUIRED BY THE N.E.C. VERIFY IN FIELD. 2. DUPLEX CONVENIENCE OUTLET MOUNTED IN WALL AT +18" A.F.F. (WHITE COVER PLATE AT WHITE WALL /PAINTED LAVENDER PLATE AT LAVENDER WALL). INSTALL WHIP AT OUTLETS WHICH FALL BEHIND TOWER FIXTURES. 3. DUPLEX CONVENIENCE OUTLET MOUNTED IN SOFFIT PER N.E.C. #210 -62 (WHITE W/ WHITE COVER PLATE) 4. NOT USED. 5. DEDICATED FOURPLEX CONVENIENCE OUTLET W/ ISOLATED GROUND MOUNTED IN CASH / WRAP COUNTER. NOTE: THE CASH - WRAP COMES WITH J -BOX AND RECEPTACLE. THE G.0 NEEDS TO MAKE THE FINAL CONNECTION AT THE PRE - DETERMINED LOCATION IN THE BASE OF THE CABINET. REFER TO SHOP DRAWINGS AS REQUIRED. 6. PHONE / COMPUTER JACK IN CASH / WRAP. TELCO TO MAKE FINAL CONNECTIONS G.0 TO PROVIDE CONDUIT W/ PULLSTRING. 7. G.F.I. CONVENIENCE OUTLET MOUNTED IN WALL NEAR SINK AT + 48" AT TOILET ROOM. 8. DISCONNECT FOR WATER HEATER. VERIFY EXACT LOCATION WITH PLUMBING TRADE. 9. J -BOX ABOVE CEILING FOR CASH / WRAP POWER CONNECTIONS. HOMERUN FROM HERE BACK TO ELECTRICAL PANEL 10. RUN ELECTRICAL, PHONES & DATA IN 3/4" RIGID CONDUITS TO CASH/ WRAP. RUN UNDER SLAB & STUB -UPS AT CASH/ WRAP COUNTER BELOW PROVIDED ACCESS PANEL IN CASH / WRAP BASE. VERIFY METHOD OF SLAB PENETRATION (USUALLY CORING OR SAW CUTTING) COORDINATE WITH MALL AUTHORITIES PRIOR TO COMMENCING THIS WORK. PATCH AND REPAIR SLAB AS REQUIRED. RUN EMT TO NEAREST ADJACENT WALL OR COLUMN ENCLOSURE. 11. 3/4" CONDUITS TO T.T.B. FOR CASH / WRAP TEL / DATA CONNECTIONS. PROVIDE PULL BOX AT THIS LOCATION OF NECESSARY. 12. NEW ELECTRICAL EQUIPMENT ASSEMBLY (IFS SWITCHBOARD) CONSISTING OF PANEL 'A'. RELAYS AND TIME SWITCH / LIGHTING CONTROL WITH BYPASS SWITCH. REFER TO ELECTRICAL ONE LINE DIAGRAM. 13. NEW 24" W. X 48" H. X 3/4 ". UNPAINTED PLYWOOD TELEPHONE TERMINAL BOARD (T.T.B.) MOUNT TO WALL A T 4 CORNERS W/ SCREWS AND WASHERS. MOUNT TOP AT 7' -0" A.F.F. OR PER OWNER'S SPECS. 14. FOURPLEX OUTLET MOUNTED AT +84" A.F.F. ON OR NEAR T.T.B. FOR TELEPHONE PHONE SYSTEM, ALARM, OR OTHER RELATED EQUIPMENT. 15. G.C. TO INTERCEPT EXISTING OR L.L. PROVIDED TELEPHONE CONDUIT TO THE SPACE AND EXTEND TO T.T.B. CLAMP TO BOARD AND PROVIDE NYLON BUSHING AT END. 16. FOURPLEX OUTLET MTD AT 52" A.F.F. FOR STEREO SYSTEM POWER. WHITE W/ WHITE COVER PLATE. COORDINATE WITH STOCK SHELF LOCATION. 17. ELECTRICAL BOX AT 52" A.F.F. W/ 3/4" CONDUIT TO STUB -UP IN REAR OF SALES AREA AT 12" ABOVE CEILING. PROVIDE NYLON BUSHING AT STUB-UP END. FOR STEREO SPEAKER WIRES. (WIRES BY OTHERS) 18. EXISTING ROOFTOP UNIT TO REMAIN. G.C. SHALL PROVIDE ALTERNATE BID TO REPLACE EXISTING UNIT WITH NEW. ELECTRICAL SYMBOL LEGEND 0 1 • v DUPLEX CONVENIENCE OUTLET +18" A.F.F. U.N.O. DUPLEX CONVENIENCE OUTLET, SPLIT WIRED, @ +18" A.F.F. U.N.O. DUPLEX CONVENIENCE OUTLET © +42" A.F.F. U.N.O. FOURPLEX RECEPTACLE FLOOR OUTLET SPECIAL OUTLET, VERIFY NEMA CONFIGURATION WITH EQUIPMENT JUNCTION BOX, IN ACCESSIBLE LOCATION' JUNCTION BOX IN ACCESSIBLE LOCATION WITH FLEXIBLE CONDUIT CONNECTION TO LIGHTING FIXTURE OR EQUIPMENT AS NOTED TELEPHONE OUTLET (WITH 3/4' C, STUBBED- `ABOVE CEILING U.N.O.) @ +18" A.F.F. TELEPHONE OUTLET, FLOOR MOUNTED;; (S,TUBk 3/,4" E.C:: ABOVE;,ACCESSIBLE CEILING), DATA OUTLET AT +18" OR AS NOTED. STUB 3/4" E.C. INTO ACCESSIBLE CEILING SPACE. INDICATES CIRCUIT IN CONDUIT CONCEALED IN WALL OR CEILING SPACE INDICATES HOMERUN TO PANELBOARD OR AS NOTED. HASH MARKS INDICATE NUMBER OF CONDUCTORS. NO HASH MARKS INDICATES 2 #12 AWG, 1 #12 BOND, 1/2" CONDUIT PANELBOARD DISCONNECT SWITCH - SIZE AND FUSES PER MANUFACTURER'S RECOMMENDATIONS (WEATHER- PROOF WHERE OUTSIDE) Q C A.F.F. A.D.A. C. C/B E.C. E.D.F. EF F.B.O. GFI GFCI GND ISO IG NL REC S.E.S. T.M.B. T.T.C. U.N.O. U/C WH WP XFMR THERMOSTAT OUTLET, +48" A.F.F. WITH 4S BOX AND PLASTER RING MOTOR - SIZE AS INDICATED IN DRAWINGS SINGLE POLE SWITCH H.P. RATED MANUAL MOTOR STARTER WITH THERMAL OVERLOAD PROTECTION. (WEATHERPROOF WHERE OUTSIDE) SMOKE DETECTOR (MATCH EXISTING) DUCT SMOKE DETECTOR (MATCH EXISTING) TIMECLOCK INTERMATIC, T7401B. ABOVE FINISHED FLOOR AMERICAN WITH DISABILITIES ACT CONDUIT CIRCUIT BREAKER EMPTY CONDUIT WITH PULL CORD ELECTRICAL DRINKING FOUNTAIN (VERIFY ROUGH -IN REQUIREMENTS) EXHAUST FAN FURNISHED BY OTHERS, INSTALLED BY ELECTRICAL CONTRACTOR GROUND FAULT INTERRUPTER GROUND FAULT CIRCUIT - INTERRUPTER GROUND ISOLATED ISOLATED GROUND NIGHT LIGHT RECEPTACLE SERVICE ENTRANCE SECTION TELEPHONE MOUNTING BOARD. 4'Wx8'Hx3 /4 "D PLYWOOD WITH #6 CU. STORE NO. 8/06 COPYRIGHT NOTICE: THESE DRAWINGS AND SPECIFICATIONS ARE COPYRIGHTED AND SUBJECT TO COPYRIGHT PROTECTION AS AN "ARCHITECTURAL WORK" UNDER SEC. 102 OF THE COPYRIGHT ACT, 17 U.S.C. AS AMENDED DECEMBER 1990. THE PROTECTION INCLUDES, WITHOUT LIMITATION, THE OVERALL FORM, ARRANGEMENT AND COMPOSITION OF SPACES, AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE DRAWINGS AND SPECIFICATIONS MAY RESULT IN CESSATION OF CONSTRUCTION, BUILDING SEIZURE, AND /OR MONETARY LIABILITY. LL_J L_LJ 0 0 0 WESTFIELD SCUTHCE \TER 2800 SOUTHCE\TER vALL - SPACE 432 ( ) W 0 E CY W 0 0 U 0 0 w FILE COPY Permit No.J c ' i \ Plan review approval is subject to errcxs and omissions, Approval of construction documents not auth r!:3 the violation of any adopted code or cinance. Rec !p't of approved Field Copy conditions is acknowiartgvd: By Date: City Of Tukwila BUILDING DIVTS [ON RECEIVED JUN 28 2011 PERMIT CENTER GROUND WIRE TO APPROVED GROUND. TELEPHONE TERMINAL CABINET. 30 "Wx36 "Hx6 "D 16 GA. WEATHERPROOF E/W HINGED LOCKABLE COVER 5/8" PLYWOOD BACKBOARD, PROVIDE A #6 CU. GROUND WIRE TO APPROVED BUILDING GROUND. UNLESS NOTED OTHERWISE UNDER COUNTER WATER HEATER WEATHERPROOF (RAINIIGHT) TRANSFORMER ELtN 05b3 DON PENN CONSULTING ENGINEER 635 WESTPORT PARKWAY, SUITE 300 GRAPEVINE, TEXAS 76051 817 - 410 -2858 FAX 817 - 251 -8411 DATE: SCALE: 5/20/2011 SHEET: As Noted DRAWN BY: 4 PROJECT No.: STORE NO. 8/06 COPYRIGHT NOTICE: THESE' DRAWINGS AND SPECIFICATIONS ARE COPYRIGHTED AND SUBJECT TO COPYRIGHT PROTECTION AS AN "ARCHITECTURAL WORK" UNDER SEC. 102 OF THE COPYRIGHT ACT, 17 U.S.C. AS AMENDED DECEMBER 1990. THE PROTECTION INCLUDES, WITHOUT LIMITATION, THE OVERALL FORM, ARRANGEMENT AND COMPOSITION OF SPACES, AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE DRAWINGS AND SPECIFICATIONS MAY RESULT IN CESSATION OF CONSTRUCTION, BUILDING SEIZURE, AND /OR MONETARY LIABILITY. 0 5 W ce LLJ LLJ CD U 0_ 0 CID LLJ LLJ U 0 n LLJ LL_ 1 I 1 2800 SOUTH CE \TER VALL - SPACE 432 c=,3 0 U LlO5b3 DATE: 5/20/2011 SHEET: SCALE: As Noted DRAWN BY: PROJECT No.: ELECTRICAL SPECIFICATIONS & NOTES PANEL SCHEDULES LIGHT FIXTURE SCHEDULE GENERAL NOTES • CONTRACTOR SHALL VISIT THE SITE AND FAMILIARIZE HIMSELF WITH THE EXISTING CONDITIONS UNDER WHICH HE IS TO PERFORM HIS WORK. NO ALLOWANCE WILL BE MADE FOR FAILURE TO COMPLY. • INFORMATION SHOWN ON PLANS AS EXISTING SHALL BE FIELD VERIFIED BY ELECTRICAL CONTRACTOR. ANY DISCREPANCY SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER FOR CLARIFICATION PRIOR TO STARTING WORK. • ALL ELECTRICAL WORK SHALL BE DONE IN ACCORDANCE WITH THE LATEST ADOPTED NATIONAL ELECTRICAL CODES AND ALL APPLICABLE FEDERAL, STATE AND LOCAL CODES AND ORDINANCES. • VERIFY EXACT LOCATION, MOUNTING HEIGHT AND ALL ELECTRICAL REQUIREMENTS OF ALL EQUIPMENT PROVIDED BY OTHERS INCLUDING BUT NOT LIMITED TO HVAC, WATER HEATERS, GENERATORS, ETC. CONTRACTOR SHALL COMPARE NAMEPLATE RATINGS OF EQUIPMENT SUPPLIED WITH THE REQUIREMENTS NOTED ON THESE DRAWINGS AND ADVISE ENGINEER OF ANY DISCREPANCY PRIOR TO ROUGH -IN AND WIRING OF EQUIPMENT. • ALL WIRING SHALL BE COPPER, THHN /THWN OR XHHW INSULATED IN CONDUIT. MINIMUM CONDUIT SIZE E TO B0E 1/2 ". PROVIDE INSULATED COPPER BOND WIRE ON ALL RACEWAYS SIZED PER • REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATION OF LIGHTING FIXTURES. VERIFY CEILING TYPES AND PROVIDE NECESSARY MOUNTING HARDWARE TO ACCOMODATE LIGHT FIXTURES USED. PROVIDE SLOPE CEILING ADAPTERS WHERE REQUIRED. • ADDITIONAL EXIT SIGNS AND EMERGENCY LIGHTING MAY BE REQUIRED. ADDITIONAL FIXTURES SHALL BE LOCATED AS DIRECTED BY THE LOCAL BUILDING INSPECTOR OR ARCHITECT. • DUPLEX RECEPTACLES MOUNTED WITHIN 6 FEET OF SINK OR LAVATORY SHALL BE GFCI. A.D.A. NOTES PANEL A Service: 120/208 Volts 3 Phase 4 Wire Cabinets: Surface Mounted Mains: 100 Amp Main Circuit Breaker 100 Total Watts: 25320 NEMA 1 REM CKT DESCRIPTION WATTS WIRE BKR A B C BKR WIRE DESCRIPTION WATTS CKT REM 1 RTU -1 3000 4 3/60 X 1/20 12 SIGNAGE 1200 2 1,2,5 - CEILING PLAN SYMBOL LEGEND 1 3 3000 X SPARE 4 5 3000 X 1/20 12 STOREFRONT LIGHTS 264 6 1,2,5 1,2,6 7 LIGHTS -SALES 464 12 1/20 X 1/20 12 RECEPT -SALES 540 8 TYPE SYMBOL MANUFACTURER /PART # LAMP(S) DESCRIPTION 9 SPARE 1/20 X 1/20 12 RECEPT -SALES 540 10 A /AE LIGHTOLIER 4x4PLWHW /4x4132HU PHILIPS PL- T32W/830/4P /ALTO RECESSED SQUARE APERTURE LENSED SINGLE LAMP COMPACT FLUORESCENT DOWNLIGHT W/ WHITE TRIM & FLANGE W/ 90 MINUTE BATTERY BACK -UP. 1,2,6 11 LIGHTS- SALES 433 12 1/20 X 1/20 12 RECEPT -SHOW WIN. 1500 12 1,2,6 13 LIGHTS -SALES 172 12 1/20 X 1/20 12 RECEPT - SHOW WIN. 1500 14 ❑ , 1,3 15 EXIT /EMER/NL 217 12 1/20 X 1/20 12 RECEPT -SHOW WIN. 1500 16 1 17 LIGHTS- STKRM/TLT 278 12 1/20 X 1/20 12 RECEPT- STOCK/TLT 360 18 1.2.6 19 LIGHTS -SALES 200 12 1/20 X 1/20 12 RECEPT- STEREO 1000 20 B /BE CON -TECH RA4439T4 -WW -120 GE CMH39T /U930GU6.5 RECESSED SQUARE APERTURE LENSED SINGLE METAL HALIDE WALL WASHER W/ WHITE TRIM & FLANGE 1,2,6 TRACK 120 12 XX 21 SPARE 1/20 1/20 1/20 12 RECEPT- CASHREG. 360 24 3,8 = 1,2,6 25 LIGHTS- PENDANTS 120 12 1/20 X 1/20 12 RECEPT -TTB 360 26 3 1,2,6 27 COVE LIGHTS 352 12 1/20 X 1/20 SPARE 28 C CON -TECH RAN2016MH- X1- P -120V PHILIPS CDM -MR16 20W/830 25D RECESSED SQUARE APERTURE SINGLE LAMP METAL HALIDE ADJUSTABLE ACCENT LIGHT, FINISH WHITE 29 SPARE 1/20 X 1/20 SPARE 30 0 1,2,6 31 LIGHTS- CHANDELIERS 120 12 1/20 X 1/20 SPARE 32 4 33 WATER HEATER SPARE 2080 10 2/30 1/20 X 1/20 SPARE 34 35 37 2060 X X 1/20 1/20 SPARE SPARE 36 38 C2 C3 CON -TECH RAN2016MH- X2- P -120V CON-TECH RAN2016MH- X3- P -120V PHILIPS 830 CDM -MR16 20W / 25D PHILIPS CDM -MR16 20W 830 / 25D SIMILAR TO TYPE C W/ (2) LAMPS & RECTANGULAR APERTURE SIMILAR TO TYPE C W/ (3) LAMPS & RECTANGULAR APERTURE 0 0 39 TIME CLOCK 100 12 1/20 X 1/20 SPARE 40 3 41 PRC -15 CNTRL PANEL 100 12 1/20 X 1/20 SPARE 42 REMARKS TOTAL LOAD PHASE 'A 8676 1 CONTINUOUS LOAD OR LARGEST MOTOR TAKEN AT 125% TOTAL LOAD PHASE 'B 8269 2 SMART BREAKER TOTAL LOAD PHASE 'C 8375 3 CIRCUIT BREAKER WITH LOCK -ON DEVICE 4 CIRCUIT POSITION BREAKER CAPABLE OF BEING LOCKED IN THE TOTAL LOAD ALL PHASES 25320 WATTS OPEN POSITION 70.33 AMPS 5 THRU TIMECLOCK CONTROL ZONE A 6 THRU TIMECLOCK CONTROL ZONE B 7 NON- COINCIDENTAL LOAD (LARGEST OF CLG /HTG LOAD USED) 8 PROVIDE DEDICATED GROUND 0 0 0 LIGHT SWITCHES, ELECTRICAL OUTLETS, THERMOSTATS AND OTHER ENVIRONMENTAL CONTROLS SHALL HAVE OPERABLE PARTS OF THE CONTROLS LOCATED NO HIGHER THAN 48" AND NO 15" " LOWER THAN 15 ABOVE THE FLOOR. IF THE REACH IS OVER AN OBSTRUCTION BETWEEN 20" AND 25" IN DEPTH, THE MAXIMUM HEIGHT IS REDUCED TO 44" FOR FORWARD APPROACH OR 46" FOR SIDE APPROACH, PROVIDED THE OBSTRUCTION IS NO MORE THAN 24" IN DEPTH. OBSTRUCTIONS SHALL NOT EXTEND MORE THAN 25" FROM THE WALL BENEATH A CONTROL. D e CON -TECH CTL802720MTL -P -FA- 8027- P- LF16 -CL - LT- B- P- LA- 23T- R- P- REGI -P PHILIPS CDM -MR16 20W 80 / 10 DEGREE TRACK MOUNTED METAL HALIDE ADJUSTABLE ACCENT LIGHT, FINISH WHITE. SUPPLY WITH 8' SINGLE CIRCUIT CURRENT TRACK AND 120 WATT CURRENT LIMITER. F -42 F -66 F -90 BARTCO F -22: BFLSLM - 14/6/120 F -34: BFLSLM- 21/6/120 F -46: BFLSLM- 28/6/120 F -58: BFLSLM- 35/6/120 PHILIPS 14W T T5 5 21W T5 28W T5 35W T5 SURFACE MOUNTED TWO -LAMP CHANNEL WITH 6" MAX. OVERLAP FOR INSTALLATION IN AN ARCHITECTURAL LIGHT COVE. FILL COVE FROM END TO END WITH NO DEAD SPOTS; EMERGENCY WIRING AS SHOWN ELECTRICAL LOAD SUMMARY 120/208 3 PH - 4W IFS PANELBOARD ELEVATION 120/208V LOAD DESCRIPTION CONNECTED LOAC (WATTS) DEMAND FACTOR DEMAND LOAD (WATTS) DEMAND LOAD (AMPS) G (5) LDCT3WH3OK (100W LIMITING DEVICE) CORD MOUNTED DECORATIVE CHANDELIER W/ WHITE ORGANZA SHADE (34710) & CRYSTALS. 12 "x44" SIZE. UNDERSIDE OF FIXTURE AT 6' -8" A.F.F. LIGHTING 2740.0 1.25 3425.0 9.5 SHADES OF LIGHT CH08056 RECEPTACLES 8020.0 NOTE #1 8020.0 22.3 AEVIEWEU t-OH COMPLIANCE WITH WATER HEATERS 4160.0 1.25 5200.0 14.4 SIGNAGE MISC. 1200.0 200.0 1.25 1.00 1500.0 200.0 4.2 0.6 NFPA 70 - NEC JUL o % 2011 H �__, BROAN #670 RECESSED FAN (SUPPLIED BY T.G.C.) HVAC 9000.0 NOTE #2 9187.5 25.5 K LIGHTOLIER SW4S232HPF120S0 2 4' -0" T8 - 32 ( ) WATTS STOCKROOM STRIP LIGHT INSTALLED TO CEILING - O oi 1- I I MCB Clock L DAINOLITE 85302 - 152211 -117 (8) LDCT3WH3OK (100W LIMITING DEVICE) REAR ALCOVE DECORATIVE CHANDELIER, 22" DIAM, 14" HT., CORD MOUNTED W/ WHITE ORGANZA SHADE & CRYSTALS. TOTAL 25320.0 27532.5 76 NOTES: 1. 100% OF FIRST 10,000 WATTS , PLUS 50% OF REMAINING LOAD. 2. 100% OF A/C LOAD, PLUS 25% OF HIGHEST LOAD. „s _-_. (r'I Of Tukwila tj/ DIVISION D PaBnel BUILDING M SIGN LIGHTER TBD TBD e EXC ® V902�RI LB -RC -BA EXIT SIGN, LED, ACRYLIC EDGE -LIT, CEILING MOUNTED W/ 90 MIN BATTERY BACKUP ° 20.00" EXL D_4 EXITRONIX LL90 -BLANK EMERGENCY LIGHT, CEILING MOUNTED W/ 90 MIN BATTERY BACKUP * ENCLOSURE IS 5 -3/4" DEEP EXM EXITRONIX VEX- U- BP- WH -EL90 EXIT /EMERGENCY LIGHT COMBO UNIT, CEILING MOUNTED W/ 90 MIN BATTERY BACKUP CURRENT LIMITING BREAKER SCHEDULE _ S 000 U ERD8,S S62 SPRINKLER HEADS (SEE SPRINKLER DRAWINGS FOR DETAILS) PANEL TCL -1 BKR WATTS CKT DESCRIPTION 1.OA 120 21 SALES TRACK LIGHTING 3.OA 300 25 SALES PENDANT LIGHTING 5.OA 500 31 SALES CHANDELIER LIGHTING SPACE SPACE SPACE SINGLE SINGLE LINE DIAGRAM NOTES LINE DIAGRAM 60/3P/NF/WP SPACE SPACE SPACE SPACE RTU -1 SPACE (3) #8& (1) #10 GND - SPACE 1. THE DISTRIBUTION PANELBOARD IS SUPPLIED BY THE OWNER AND INSTALLED BY THE EC. LANDLORD TENANT IN 3/4 "G NOTES ROOF 2. INFORMATION REGARDING THIS EQUIPMENT MAY BE OBTAINED FROIA BEN FACTOR AT WR CONTROLS / WESCO PH: 1- 800 - 417 -7543 3. THE PANELBOARD IS A WALL MOUNTED UNIT. THE NEW (4) #1 & (1) CONTRACTOR IS RESPONSIBLE TO MAKE ALL FINAL ■,,, TERMINATIONS. #6 GND IN 1- 1/4 "C. 1. ROUTE ALL LIGHTING CIRCUITS FROM BREAKER PANEL B TO BREAKER TCL -1 PANEL, LANDING EACH LIGHTING CIRCUIT ON THE INPUT SIDE OF THE SUPPLEMENTAL "BREAKER ". 2. WIRE FROM THE OUTPUT SIDE OF EACH SUPPLEMENTARY "BREAKER" TO THE TRACK /LIGHTING FIXTURES. 3. PROVIDE QUANTITY OF SILVER BULLET BREAKERS/ PANELS TO ACCOMMODATE ALL LIGHTING CIRCUITS. 4. BREAKERS SHALL LIMIT FIXTURE LOAD TO AMPS SHOWN ABOVE. 5. BREAKERS FED FROM CORRESPONDING CIRCUIT NUMBER IN PANEL INDICATED. 1 REFER TO IFS PANEL GENERAL NOTES FOR 4. THE TIME CLOCK IS FACTORY INSTALLED & WIRED TO THE APPROPRIATE LIGHTING ZONE. THE EC IS RESPONSIBLE FOR ALL TIME CLOCK PROGRAMMING. 5. A 24 -HOUR NOTICE WILL BE GIVEN PRIOR TO DELIVERY. 6. THE ELECTRICAL CONTRACTOR SHALL COMPLETE THE INITIAL TIME CLOCK SET -UP, PRIOR TO LEAVING THE JOB; COORDINATE HDURS OF OPERATION, INCLUDING SEASONAL TIME CHANGES AND HOLIDAY SCHEDULES, WITH THE TENANT'S STORE MANAGER AND /OR DISTRICT SALES (E) 3P /100A OVERCURRENT PROTECTION ADDITIONAL I INFORMATION ON ECLOCK IFS ENCLOSURE, REFER TO IFS DETAIL FOR ACTUAL 100A ( EXISTING TG DIMENSIONS AND LAYOUT. METER --� (E) LANDLORD DISTRIBUTION PANEL PANEL ,�A ,� 120/208 V MANAGER. TIME CLOCK IS INTERMATIC #ET- 70215C AND IS CEC TITLE 24 COMPLIANT W/ ANNUNCIATION & OVERRIDES. 7. THE ELECTRICAL SERVICE TYPE AND SIZE MUST BE APPROVED BY THE LANDLORD'S DIRECTOR OF CONSTRUCTION BEFOREHAND. 8. SHIPPING WEIGHTS: 208V IFS PANEL = 130 LBS. IG G 30, 4W N (E) PER N.E.C. GRD. ....] FLOOR 9. NOTIFY ENGINEER IMMEDIATELY IF FIELD CONDITIONS -- DIFFER FROM PLAN LAYOUT. - 10. INTEGRATED FACILITY SYSTEMS (IFS) IFS PANEL TO BE PROVIDED BY W.R. CONTROLS / WESCO. THIS ITEM IS PROVIDED BY THE TENANT AND INSTALLED BY THE GC'S . I ELECTRICAL CONTRACTOR. THE GC'S ELECTRICAL CONTRACTOR IS TO CONTACT MR. BEN FACTOR AT (800) EC TO FIELD VERIFY AND IF NOT EXISTING PROVIDE #8 GRD TO BUILDING STEEL OR COPPER WATER LINE. - SEC TO FIELD VERIFY AND IF NOT EXISTING PROVIDE #8 GRD TO BUILDING STEEL OR COPPER WATER LINE FOR ISOLATED GROUND. 417 -7543 TO COORDINATE DELIVERY. ADDITIONAL INFORMATION ABOUT THE IFS CAN BE FOUND AT WWW.WRCONTROLS.COM. NOTE RECEIVE[ THE ELECTRICAL CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO BID. JUN 28 2011 PERMIT CENTER ik)DON PENN CONSULTING ENGINEER 635 WESTPORT PARKWAY, SUITE 300 GRAPEVINE, TEXAS 76051 817- 410 -2858 FAX 817 - 251 -8411 STORE NO. 8/06 COPYRIGHT NOTICE: THESE' DRAWINGS AND SPECIFICATIONS ARE COPYRIGHTED AND SUBJECT TO COPYRIGHT PROTECTION AS AN "ARCHITECTURAL WORK" UNDER SEC. 102 OF THE COPYRIGHT ACT, 17 U.S.C. AS AMENDED DECEMBER 1990. THE PROTECTION INCLUDES, WITHOUT LIMITATION, THE OVERALL FORM, ARRANGEMENT AND COMPOSITION OF SPACES, AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE DRAWINGS AND SPECIFICATIONS MAY RESULT IN CESSATION OF CONSTRUCTION, BUILDING SEIZURE, AND /OR MONETARY LIABILITY. 0 5 W ce LLJ LLJ CD U 0_ 0 CID LLJ LLJ U 0 n LLJ LL_ 1 I 1 2800 SOUTH CE \TER VALL - SPACE 432 c=,3 0 U LlO5b3 DATE: 5/20/2011 SHEET: SCALE: As Noted DRAWN BY: PROJECT No.: