Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit EL11-0568 - D B E ELECTRIC, INC.
D B E ELECTRIC, INC. SOUTHCENTER PY & KUCKITAT EXPIRED 03-21-12 EL1 1 -0568 Parcel No.: Address: City oPi'ukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206-431-3665 Web site: http: / /www.TukwilaWA.gov Project Name: D B E ELECTRIC, INC. ELECTRICAL PERMIT Permit Number: Issue Date: Permit Expires On: EL11 -0568 07/28/2011 01/24/2012 Owner: Name: Address: Contact Person: Name: Address: ANNETTE O'HARE PO BOX 9169 , COVINGTON WA Contractor: Name: DBE ELECTRIC INC Address: PO BOX 9169 , KENT WA Contractor License No: DBEELEI912PM Phone: 253 887 -8089 Phone: 253 887 -8089 Expiration Date: 10/14/2011 DESCRIPTION OF WORK: INSTALL NEW SERVICE CABINET WITH TESCO BBS FOR SIGNAL - INCLUDES TRENCHING. (NO PARCEL NUMBER AVAILABLE, THIS WORK IS WITHIN DEPARTMENT OF TRANSPORTATION RIGHT OF WAY.) Value of Electrical: NRES: $16,000.00 RES: $0.00 Type of Fire Protection: UNKNOWN Electrical service provided by: Permit Center Authorized Signature: I hereby certify that I have read and governing this work will be complie Fees Collected: National Electrical Code Edition: Date: $459.63 2008 d this permit and know the same to be true and correct. All provisions of law and ordinances hether specified herein or not. The granting o this permit does not pre construction o he performance of work. Signature: Print Name: to give authority to violate or cancel the provisions of any other state or local laws regulating I am authorized to sign and obtain this electrical permit. Date: 7 -Z-7 /i This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/10 EL11 -0568 Printed: 07 -28 -2011 PERMIT CONDITIONS Permit No. EL11 -0568 * *ELECTRICAL ** • 1: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 2: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 3: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 4: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 5: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 6: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. doc: EL -4/10 EL 11 -0568 Printed: 07 -28 -2011 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto://www.ci.tukwila.wa.us Electrical Permit No. j L- �' D (et Project No. (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: Tenant Name: KING COUNTY King Co Assessor's Tax No.: NO PARCEL # SW CORNER S CENTER PKWY /KLICKITAT DR Suite Number: New Tenant: Floor: ❑ Yes VI ..No Property Owners Name: Mailing Address: City State Zip CONTACT PERSON — Who do we contact when your permit is ready to be issued Name: ANNETTE O'HARE Mailing Address: P O BOX 9169 Day Telephone: (253) 887 -8089 COVINGTON WA 98042 E -Mail Address: annette @dbeelectricinc.com City State Fax Number: (253) 804 -6066 Zip ELECTRICAL CONTRACTOR INFORMATION Company Name: Mailing Address: Contact Person: DBE ELECTRIC INC P 0 BOX 9169 DBE ELECTRIC INC E -Mail Address: annette @dbeelectricinc.com Contractor Registration Number: BUS - 0992449 COVINGTON WA City State Day Telephone: (253) 887 -8089 Fax Number: (253) 804 -6066 Expiration Date: 12/31/2011 98042 Zip Valuation of Project (contractor's bid price): $ 16,000 Scope of Work (please provide detailed information): INSTALL NEW SERVICE CABINET W/TESCO BBS FOR SIGNAL INCLUDES TRENCHING. Will service be altered? ❑ Yes m No Adding more than 50 amps? ❑ Yes ❑ No Type of Use: Type of work: ▪ New ❑ Addition ❑ Service Change ❑ Remodel ❑ Tenant Improvement ❑ Low Voltage ❑ Generator ❑ Fire Alann ❑ Telecommunication ❑ Temporary Service Property Served by: ▪ Puget Sound Energy ❑ Seattle City Light Il'Applications \ rotms- Applications On Line\2010 Applications\7 -2010 - Electrical Permit Application.doc bh Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single fancily dwellings $152.85 (including an attached garage) ❑ Garages, pools, spas and outbuildings $81.90 ea ❑ Low voltage systems (alarm, furnace thermostat) $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $81.90 (no added /altered circuits) ❑ Service change with added/altered circuits $81.90 number of added circuits $11.55 ea ❑ Circuits added /altered without service change $54.60 (up to 5 circuits) ❑ Circuits added /altered without service change $54.60 (6 or more circuits) $7.65 ea ❑ Meter /mast repair $68.25 ❑ Low voltage systems $59.85 (alarm, furnace thermostat) MULTI - FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $63.00 ❑ Temporary service (generator) $78.75 ❑ Manufactured /mobile home service $84.00 (excluding garage or outbuilding) ❑ Carnivals $78.75 Number of concessions $10.50 ea PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 NER OR ELECTRICAL CONTRACTOR: Signature: a d Date: 06/27/2011 Print Name: Ai (/t/k1eA-1 —e/ D ' Ska-/C1--/ Mailing Address: P 0 BOX 9169 Day Telephone: (253) 887 -8089 IDate Application Accepted: COVINGTON iit f ( 98042 Zip City State Otp Date Application Expires: 121 It Staff Initials: H:'Applications\Fonns- Applications On Line \2010 Applicationst7- -2010 - Electrical Permit Application.doc bh Page 2 of 2 Ci, of Tukwila. • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: /hvww. ci. tukwila. wa. us SET RECEIPT Copy Reprinted on 07 -28 -2011 at 12:26:29 07/28/2011 RECEIPT NO: R11 -01602 Initials: JEM Payment Date: 07/28/2011 User ID: 1165 Total Payment: 1,470.00 Payee: DBE ELECTRIC INC. SET ID: S000001521 SET NAME: Temporary Set SET TRANSACTIONS: Set Member EL11 -0567 EL11 -0568 EL11 -0569 EL11 -0570 TOTAL: Amount 367.70 367.70 367.70 366.90 367.70 TRANSACTION LIST: Type Method Description Amount Payment Check 012311 1,470.00 TOTAL: 1,470.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.0 TOTAL: 1,470.00 1,470.00 SET RECEIPT RECEIPT NO: R11 -01343 Initials: JEM Payment Date: 06/29/2011 User ID: 1165 Total Payment: 367.72 Payee: DBE ELECTRIC INC SET ID: S000001521 SET NAME: D B E ELECTRIC SET TRANSACTIONS: Set Member Amount EL11 -0567 91.93 EL11 -0568 91:93 EL11 -0569 91.93 EL11 -0570 91.93 TOTAL: 91.93 TRANSACTION LIST: Type Method Description Amount Payment Check 012062 367.72 TOTAL: 367.72 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES 000.345.832.00.0 367.72 TOTAL: 367.72 INSPECTION RECORD Retain a copy with permit al 0C61 INSPECTION.NO. P RMIT NO. • • CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 ta+ (206) 431 -3 Permit Inspection Request Line (206) 431 -2451 Project: 6 . Type of Inspection: 7492.... Address:■�w�{$� • / turr Date Called: Specia Instruction : • Date Wanted:. 3 e,..3 Requester: ! Phone No: Approved per applicable codes. Dcorrections required prior to approval. COMMENTS: -5ecid — 64. Jcro L5 i - idifricy4 616 fInsPector:j !Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF' TUKWILA BUILDING DIVISION L 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project6 l is Type of Inspection: i�� a to s KutiCrt r vJtsr 0 Address: 1 511414 I .5P a to Ca lled: - 5 4mk &AP IA/ U4tkr al 5- 5/c4Al. 1. Ftiti Special Instruction: Date Wanted:. if Requester: Phone No: aApproved per applicable codes. Corrections required prior to approval. COMMENTS: i�� a to s KutiCrt r vJtsr 2, 614 1 Lgtil. toss/burr 1 511414 I .5P oS') 5 -C.• ' K` teLieKr'AT - 5 4mk &AP IA/ U4tkr al 5- 5/c4Al. 1. Ftiti Inspector: Date /41/// ri REINSPECTION EE REQUIRED. Prior to next inspec$ ion. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. SEPARATE PERMIT REQUIRED FOR: Mechanical Electrical O Plumbing 'E Gas Piping City of Tukwila BUILDING DIVISION MAYOR JIM HAGGERTON CITY COUNCIL JOE DUFFIE JOAN HERNANDEZ DENNIS ROBERTSON, ALLEN EKBERG VERNA SEAL KATHY HOUGARDY DE'SEAN QUINN CITY ADMINISTRATOR STEVE LANCASTER TUKWILA URBAN ACCESS IMPROVEMENT PROJECT REVISIONS No changes shall bo made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. COUNCIL PRESL,7NT PUBLIC WORKS DIRECTOR BOB GIBERSON CITY ENGINEER ROBIN TISCHMAK PROJECT MANAGER CYNDY KNIGHTON CITY OF TUKWILA, WASHINGTON SEC. 26, T. 23 N, R 4 E., W.M. SEC. 23, T. 23 N, R 4 E., W.M. TIB- 9- P- 116(012) -1 FILE COPY Permit No.. al -" 4 LOCATION MAP NOT TO SCALE Plan review approval is subject to errors and omissions. i 1roval of construction documents does not authors iolatcn of any adopted code or ordnance. Receipt of approv= . Field Copy and conditionsavitedgerkwila BY TO SEATTLE 11 MILES titVIE LC) FOR COMPLIANCE WITH NFPA 70 - NEC JUL 0 7 2011 City of ``TTu�kwila BUILDING®IVISION XING TO BE CONSTRUCTED ENO CONSTRUCTION S A. 4 +4 .00 BEGIN PROJECT BEGIN FA NO . The "'Community at the (,,i-Rtes,- c12c.1- DEPARTMENT OF PUBLIC WORKS Crossroads." City Of Tukwila BUILDING DIVISION 6300 SOUTHCENTER BLVD., SUITE 100 TUKWILA, WA 98188 (206) 433 -0179 VICINITY MAP NOT TO SCALE RECEIVED CRYOFTUKIMLA JUN 2 8 2011 PERMIT CENTER ' PUBLIC WORKS DEPT. - ENGINEERING - STREETS WATER - SEWE R R- PAKS-BUILDP" ING- a _ — TUKWILA URBAN ACCESS IMPROVEMENT PROJECT 'MO/ 1196) :, a HNTB .1m G1 TITLE AND VICINITY MAP �^� + SCGDGND � MOW* �- no d. �,nzw we. dab a�ano LEGEND TRAFFIC SIGNAL POLE TRAFFIC SIGNAL POLE W/ LUMINAIRE TYPE PS SIGNAL POLE PEDESTRIAN SIGNAL HEAD VEHICLE SIGNAL HEAD OPTICOM SENSOR SIGNAL CONTROLLER SIGNAL LOAD CENTER TYPE 1 JUNCTION BOX TYPE II JUNCTION BOX TYPE VIII JUNCTION BOX UPS CABINET VEHICLE DETECTION CAMERA POLE NUMBER COMMUNICATIONS VAULT (25 TA) CCTV CAMERA PEDESTRIAN PUSH BUTTON POLE C>_ 0 4 XX' 0 1l 0 PHASE DIAGRAM NOT 01 USED QL.6 05 02 03 NOT USED NOT USED NOT USED OLB 0 -J� 06 07 CONSTRUCTION NOTES: O7 INSTALL SPECIAL DESIGN, DUAL MAST ARM TYPE III SIGNAL STANDARD WITH A 48 FOOT MAST ARM AND A 64 FOOT MAST ARM PER DETAIL SHEET SG7. INSTALL SIX VEHICLE HEADS. TWO TYPE 711 OPTICON DETECTORS. ONE TERMINAL CABINET. AND ONE VEHICLE DETECTION CAMERA. p INSTALL TYPE PS SIGNAL STANDARD PER WSDOT STANDARD PLAN J-20.16-00. ONE PED HEAD, AND ONE PUSH BUTTON. O INSTALL ONE PEDESTRIAN HEAD WITH 8 FOOT MOUNTING HEIGHT USING TYPE E MOUNTING, AND ONE PUSH BUTTON ON NEW LIGHT STANDARD. 0 INSTALL SIGNAL INDUCTION LOOP PER PLAN AND CITY OF TUKWILA STANDARD DETAIL RS28. 0 INSTALL CITY PROVIDED TYPE P -44 STRETCH CABINET PER CITY OF TUKWILA STANDARD DETAIL 0 RS29 EXCEPT CABINET SHALL BE 60" TALL. INSTALL EAGLE EPAC M50 CONTROLLER. CONNECT FIELD WIRING TO CONTROLLER CABINET. FOLLOW SIGNAL TURN -ON AND TESTING PROCEDURES. IP 0 INSTALL TYPE 27 -22 BBS COMBINATION SERVICE/UPS CABINET PER CITY OF TUKWILA STANDARD DETAIL R522 Imo, O CONSTRUCT COMBINATION SERVICE AND CONTROLLER FOUNDATION FOR CABINETS AS PER DETAIL ON SHEET 5010. sue'= pB COIL 150' OF 72CT SMFO IN EACH COMMUNICATIONS VAULT. COORDINATE WORK WITH CITY SIGNAL - STAFF FOR SIGNAL INTERCONNECT. +00 14 +00 'f +00 - 14+00 R VEHICLE SIGNAL HEADS NO. 21,22.41 R Y e C e VEHICLE SIGNAL HEADS NO. 51, 52 R Y 0 O 0 Y e G e VEHICLE SIGNAL HEAD NO. B1 a PEDESTRIAN SIGNAL HEAD N0. 48, 49 PREEMPTION SCHEDULE EVP PHASES(S) OLB & 4 2 OLA & 5 LIGHT STANDARD SC 15 +38.7, 62.7 LT t „ Y fl Y , --4 EWED FON LIANCE WITH A70 -NEC JUL 0 7. 2011 - ; City of l ukw ila AIDING DIVISION i.% 3 o (n'P) DISPLAY NOTES 1. ALL VEHICLE SIGNAL HEADS SHALL BE CONVENTIONAL TYPE WITH LED LENSES (DURA LED) AND BE EQUIPPED WITH TUNNEL VISORS AND BACK PLATES. 2. ALL VEHICLE SIGNAL HEADS SHALL HAVE TYPE M MOUNTING. 3. ALL SIGNAL HEADS SHALL BE PAINTED GREEN ON AU. SURFACES. THE INSIDE OF VISORS AND THE FACE OF THE BACK PLATES SHALL BE FLAT BLACK. 4. ALL PEDESTRIAN SIGNAL HEADS SHALL BE LED, ICC MODEL 84092, AND COUNTDOWN STYLE. 20 10 0 20 40 SCALE IN FEET G RACEWAY/ CONDUIT SIZE DETECT LOOP 2x-/14 PED DET 2ca -�4 CAMERA �� VEH DETECT CAMERA E. V. DETECT 3x-/20 Vai HEAD 5c- 14 SINGLE PED HEAD 5e -%14 INTERCONNECT 1 -72CT SMFO REMARKS 1 1" 2 2 2" 4 3 2" 1 4 2 1 Z• SPARE 5 2" 1 2 4 2 1 6 3" 1 2 4 2 7 2" 4 1 2" 1 2 4 2 8 2• 2 -/6 9 2' 1 FOR INTERCONNECT SEE NOTE 8 SEE ILLUMINATION SHEETS FOR WIRE NOTE 1 I dO 7 +00 18+00 CO 18 +00 (� 1 I (1) 1- I- 15+001. I 17 +00 SOUTHCENTER PKWY. +00 4 ECNB” UNE cn W tea.= - _x �.�� W Z V) - — J W --_ .— _ �° RECEIVEP .-27.4-330-__ ___ --- ......_.....�:. CITY OF TUKWILA JUN 2 8 2011 cie) - �-�� PERMIT CENTER 25 +00 6+19.2, 16.9 RT PUBLIC WORKS DEPT. DIM tram duclold - ENGINEERING STREETS-WATER- SEWER PARKS- BUILDING OE AN blue HNTB TUKWILA URBAN ACCESS IMPROVEMENT PROJECT SG3 / SIGNAL PLAN SOUTHCENTER PARKWAY / KLICKITAT DR. weisixes FOUNDATION DEPTH TABLE ALLOWABLE LATERAL BEARING PRESSURE (Ps() FOUNDATION TYPE .3' ROUND 3' SQUARE 4' ROUND XYZ (CUBIC FEET) TYPE 11,10 AND SD MAST ARM STANDARDS 600 10' 8' 8' 900 10' 8' 8' 1 200 1,500 1,900 2 300 1,000 3' ROUND 3' SQUARE 4' ROUND 8' 7' 7' 11' 9' 9' 11' 9' 9' 13' 10' 10' 15' 11' 11' 1,500 3' ROUND 3' SQUARE 4' ROUND 6' 6' 6' 8' 7' 7. 9' 7' 7. 11' 8' a' 1.3' 8' a' 15' 9' 9' 2.500 6' 6' 6' 7' 6' 6' 11' 6' 6' 13' 7' 7. _ 15' 7' 7' THIS TABLE BASED ON A 0 VALUE OF 26'. FOR DOUBLE MAST ARM STANDARDS WITH 90' BETWEEN ARMS, USE THE LARGER XYZ VALUE FOR FOUNDATION DEPTH SELECTION. A SPECIAL FOUNDATION DESIGN IS REQUIRED FOR DOUBLE ARM STANDARDS IF THE ANGLE IS NOT 90'. UNPAVED SURFACE CLASS 3000 CONCRETE 3 8" DIA. PLASTIC DRAIN TUBE GROUT PAD THICKNESS= d NUT HT. +1" MAX ICI ICI Sirainfirial PAVED SURFACE 8 NO. 8 BARS EQUALLY SPACED 2•" CL #4 HOOPS, RD. OR SQ. AT 1' -0" APPROX. CTRS. 3' SQ. OR RD., OR 4' RD. FOUNDATI ON DETAI L FOUNDATION DE Coo W J i 0 a 0' cal ENTAT/ON 0 1t E2 ;90' 180' 90' - 270' 0' 0 ANCHOR BOLT PLATE° b POLE ORIENTATION LINE POLE ORIENTATION AND ATTACHMENT POINT DETAIL ATTACHMENT POINT ALL HANDHOLES AT 180' FROM El SI GNAL STANDARD I DENTI FI CATI ON TAG DETAI L EXAMPLE STD. NO. XX SRXXX. MP XXX.XX MANUFACTURER APPROVED DWG. XXXXXX FAB. X/XX/XXXX SIGNAL STANDARD NO. STATE ROUTE AND MILE POST NO. APPROVED DRAWING NO. FABRICATION DATE STD. NO. 02 SR97, MP 069.09 MANUFACTURER APPROVED DWG. A812345 FAB. 6/14/2002 NOTE: CORROSION RESISTANT METAL TAG SECURED WITH (2) 0.125" RIVETS AS FOLLOWS: POLE SHAFT - LOCATED WITHIN 6" ABOVEHAND HOLE, SIGNAL AND LUMINAIRE MAST ARM - LOCATED WITHIN 6" OF THE POLE SHAFT CONNECTION POINT. TEXT SHALL BE A MINIMUM OF 3/16" HIGH. STAMPED OR EMBOSSED. IF El OR E2 SIGNAL ARM IS NOT NINETY DEGREES TO THE ANCHOR BOLT PLATE THEN SPECIAL DESIGN POLE LOCATION STATION H�- POLE ORIENTATION ANGLE (P.O.A.) DEGREES CLOCKWISE FROM OFFSET LINE TO POLE ORIENTATION UNE (SETS ANCHOR BOLT ORIENTATION) POLE CAP CAMERA MOUNTI NG DETAI L C VIE' WITH NFPq 70 . NEC 85 SIGNAL DISPLAY VERTICAL CLEARANCE (FEET) FROM STOP UNE 40' 45' Sn• F 53' -150' 3 SECTION 12" 17.5' 19.2' 20.9' 22.0' 4 SECTION 12" 17.0' 18.0' 19.7' 20.8' 5 SECTION 12' 17.0' 17.5' 18.5' 19.6' G LIMITS OF VERTICAL CLEARANCE REQUIREMENT TYPE II MAST ARM SIGNAL STANDARD ROADWAY STD. 1 FIELD LOCATION AUCNMENT STATION OFFSET LTRT,..O.A TYPE SC 16+19.2 16.9 X 180 MOUNTING HEIGHT(FT) Al A2 SIGNAL STANDARD DETAIL CHART "CURB OR EDGE OF SHOULDER OFFSET DISTANCES 82 83 44 61 11 19 49 39 (FT) (Z) S POLE TO ATTACHMENT POIN 85 84 32 34 19 63 58 60 2 SC 15 +54.0 84.2 X 0 PS 10 3 SC 15+38.7 62.7 X 0 UGHT NOTES 0 MOUNTING COUPLING INSTALLED AT OFFSET DISTANCE INDICATED IN CHART. SIGNAL MAST ARM DMA n 86 87 B9 810 811 B1 82 83 30 53 ALTERNATE NOTE 1 FOR TYPE N MOUNT ONLY 20 7 9.3 14 9.3 NINDLOAD AREAS B4 85 86 14 9.3 (Fn 2(XI21 810 611 B7 89 9.3 5 (X)(Y)(Z) TOTAL(FTT1 23824 LUMINAIRE ARCFT) POLE ATTACHMENT POINT ANGLES D El E2 F G1 02 0 7 11.6 12 9.3 16.5 2035.2 103 (deg) H 11 270 FOUNDATION DEPTHS(FT) REMARKS 12 3' RD.13' 5014' RD. SPECIAL NA 270 270 DRILL 1" HOLE IN MAST ARM AND INSTALL PLASTIC SPLIT BUSHING FOR CABLE ENTRANCE. NA 90 90 PUBLIC WORKS DEPT. - ENGINEERING- STREETS - WATER- SEWER - PARKS -B UILDII IG- O2 FIELD INSTALLED. mb.e APIS awn cbsdad 8 Re •,11 KG bid ago HNTB *F1,CV1) TUKWILA URBAN ACCESS IMPROVEMENT PROJECT A. B. C. D. E. F. G. H. RECEIVt CITY OF TUK LA JUN 2 8 2011 PERM1T CENTE SG7 / SIGNAL STANDARD DETAILS - SOUTHCENTER PARKWAY! KLICKITAT DRIVE LEGEND VEHI CLE DI SPLAY SI GN STREET NAME SIGN PRE -EMPT DETECTOR DELETED (10/22/90) LUMI NAI RE PEDESTRIAN DISPLAY CABI NET PPB -M HANDHOLE R inisions ,l\ ecn a 1s1� C131� 196, Sew 60500793 m6 6 1 T I] fee 99113110 1.5' LUMINAIRE ARM DOME CAMERA DETAIL 1 DOME CCTV CAMERA ON LUMINAIRE ARM MOUNTING DETAIL NOTES 1. MANUFACTURER TO INSTALL 1) "COUPLER SIGNAL MAST ARM DETAIL 2 VIDEO DETECTION CAMERA ON SIGNAL POLE MAST ARM MOUNTING DETAIL NOTES 1. THE CONTRACTOR SHALL DRILL A 1 1/2" HOLE IN THE BACK SIDE OF SIGNAL MAST ARM, DEBURR AND PUT A RUBBER GROMMET IN HOLE. 15 FEET OF VIDEO DETECTION CABLE SHALL BE PULLED THROUGH THE MAST ARM, THROUGH THE 1" HOLE, AND COILED. THE COILED CABLE SHALL BE SECURELY ATTACHED TO THE MAST ARM WITH ZIP TIES FOR TERMINATION BY COT. elA14);(07 ritVIEWED Fail COMPLIANCE WITH NFPA70 -NEC JUL 072011 City of Tukwila BUILDING DIVISION DETAIL 3 LUMINAIRE ARM VIDEO DETECTION CAMERA ON LUMINAIRE ARM MOUNTING DETAIL NOTES 1. THE CONTRACTOR SHALL DRILL A 1 1/2" HOLE IN THE TOP OF THE LUMINAIRE MAST ARM, DEBURR AND PUT A RUBBER GROMMET IN HOLE. 10 FEET OF CABLE SHALL BE PULLED THROUGH THE LUMINAIRE ARM, THROUGH THE 1" HOLE. AND COILED. THE COILED CABLE SHALL BE SECURELY ATTACHED TO THE LUMINAIRE ARM WITH ZIP TIES FOR TERMINATION BY COT. RECEIVF,p _ CITYOFTUKwiLA JUN 2 8 2011 PERMIT CENTER PUBLIC WORKS DEPT. - ENGINEERING - STREETS - WATER- SEWER - PARKS- BUILDING- pys HNTB TUKWILA URBAN ACCESS IMPROVEMENT PROJECT SG9 CAMERA MOUNTING DETAILS • VARIES CONTROLLER CABINET PER CITY OF TUKWILA STD. DETAIL RS -29 3' MIN. I 1 I I VARIES V MIN VARIES CLASS 3000 CONCRETE 2" CLEAR (TYP.) z -J U L 1 1 1 COMBINATION UPS /SERVICE CABINET SEE SPECIAL PROVISIONS TO SIGNALS TO SOURCE OF PHONES NOTE: SEE TRAFFIC SIGNAL PLAN FOR NUMBER AND SIZE OF CONDUIT TO POWER SOURCE TO UGHTING CRUSHED SURFACING BASE COURSE CONTROLLER /SERVICE FOUNDATION DETAIL N.T.S. #4 REBAR ® 12" 0.C. EACH WAY CRUSHED SURFACING BASE COURSE(2" DEPTH) GENERAL 1. SEE PLAN SHEETS FOR CABINET LAYOUT AND ADJUST FOUNDATION DIMENSIONS AS NECESSARY TO THE SATISFACTION OF THE ENGINEER 2. PROVIDE ADEQUATE CLEARANCE BETWEEN CABINETS FOR DOORS TO OPEN. C FPLIANCE V ;: PA 70 - NEC JUL 0 7 2011 City Of TuI:IAlII~ BUILDING DIVISION -ENGINEERING-STREETS-WATER-SEINER-PARKS-BUILDING- TUKWILA ENGI NEERI NG- STREETS - WATER- SEWER - PARKS- BUILDING- TUKWILA URBAN ACCESS IMPROVEMENT PROJECT RECEIVE CITY OF TUK LA JUN 2 8 2011 PERMIT CENTER L SG10 CONTROLLER/SERVICE FOUNDATION DETAIL ADDENDUM CI nrisk o 134 196, SO SKI ScSGD109 male NTS Eele 09gY10 1 VARIES CONTROLLER CABINET PER CITY OF TUKWILA STD. DETAIL RS -29 VARIES 3' MIN. 1' MIN TO SIGNALS TO SOURCE OF PHONES 1 1' MIN 1' MIN. 2" CLEAR (TYP.) I I I I i I I i 'lT F-1 S I I 1_�L_J_ I i I I I I I - - +- 1 I I I I I r T I I I I I I I I UPS CABINET SEE SPECIAL PROVISIONS VARIES CLASS 3000 CONCRETE 3" CLEAR SERVICE CABINET A PER CITY OF TUKWILA STD. DETAIL RS -22 1 1 1 1 1 J L_. NOTE: SEE TRAFFIC SIGNAL PLAN FOR NUMBER AND SIZE OF CONDUIT CONTROLLER /SERVICE • TO POWER SOURCE TO LIGHTING CRUSHED SURFACING BASE COURSE UNDATION DETAIL Pt1LIC WORKS DEPT. 8" #4 REBAR ® 12" 0.C. EACH WAY CRUSHED SURFACING BASE COURSE(2" DEPTH) GENERAL 1. PLAN SHEETS FOR CABINET LAYOUT AND ADJUST OUNDATION DIMENSIONS AS NECESSARY TO THE SATISFACTION OF THE ENGINEER. 2. PROVIDE ADEQUATE CLEARANCE BETWEEN CABINETS FOR DOORS TO OPEN. RECEIV CITYOFTU IA JUN 2 8 2011 PERMIT CEN - ENGINEERING- STREETS - WATER- SEWER - PARKS- BUILDING- HNTB TUKWILA URBAN ACCESS IMPROVEMENT PROJECT SG10 CONTROLLER/SERVICE FOUNDATION DETAIL 196, Se no SCSGDTCB NTs do 011/13710 a i i 1 SIGN HEA IGNAL PED. HEAD PED. H 62 1/61 68 o w..a ®P VPQ 00000 404010 C O 0 m= 0 O= 0 0 0 O 0 0 0 ►IIt TERM NAL CABINET I25A I25B� I25CI 124A 1 248 3 -2CS 24C PED POLE 3A 0 SIGNAL POLE .3 0 O 10 INn Idaw m 1 1 1 Cr 0 2 0 1 1 1 1 1 1 1 1 C 0 0 0 if I I ( NI1V4 0000(0 010100b MEM 1 1 1 JUNCTION 80X JUNCTION BOX 111 O N 53 I238 \ 123C 3 -2CS a JUNCTION BOX JUNCTION BOX v 40 r-1 1T1 mozos 1 3CS. 4 -5C 40 Cl; a 0_ 0 0 E V.P. 3 0 - Y BL- a 531 532 533 SIGNAL HEAD 82 R 681 -8 - -0 - Y 682 G H 683 -G - 684 -8 - 686 -M SIGNAL POLE '4 PED POLE •48 m 01 m0 I0 1 1 m 0 IC OA v 10 PED. HEAD 88 R G M 78 0 784 8 785 sel#11--Gc(91 7-2cS 52 22A 22B 22C 51 21A ) 218 ) 21C PED POLE 2A 8 -2c5 UNCTION BOX 5 -2CS PED. HEAD 69 HEAD 88 SH�L 81.82 01 tsN- 000040 Na0N- 0 01 01 01 01 CO CO m CO CO TM 4N u — 1 n ulna u 1 Irn 1 u n I i w m m 0000, 020=0SC00027 111111ijJjIIIII 0 B 784 785 P.P.B. 88 PED POLE '4A JUNCTION BOX 5-2C5 TERMINAL CABINET JUNCTION BOX 2 -205 618 61A II 62B 62A 12 1 638 63A 13 SOUTHCENTER PARKWAY 5 _J 2 JUNCTION 80X TERMINAL CABINET JUNCTION BOX P.P B. 480 744 745 L B- DOUBLETREE DRIVEWAY 8 -2CS. 1 -CC 3-5C. 1 -3CS 4 8 SIGNAL HEAD 42 - R 641 d111f 11 C o 0 m 2C 0 s O CO C 0 s 0 m EltliiiiliEglEi SIGNAL HEAD PED. PED. H4E8 HE PED. HEAD 48 SIGNAL POLE •2 a, 0 a ¢OZO4 Eggqg 64 - G 64 - 8-644 - N_-1646 MCDONALDS DRIVEWAY 6 r— 1 CO u PED POLE •1A SIGNAL HEAD 41 -R -641 R -0- -6- -8-644 646 14A5T ARM ERE o (10 642 Y 643 G 01 N Z l r Nx 1 0 0 0 0 > 1 1 1 1 1 02222 Z CO 0 0 0 z N r N x 0 w= Z CO Cf00 1 1 1 1 1 O JUNCTION BOX 2 -2CS 68 '8'd'd _8 -SBL 0 68L� BI• 310d 03d TO CONTROLLER CABINET JUNCTION BOX 4 -3CS. 14 -5C. 19 -2CS. 3 -CC 1 648 64A JUNCTION BOX 1 658 65A CONTROLLER t#EVIEWED Fir COMPLIANCE WIT in NFPA 70 m NEC JUL 0 7 2011 City of Tukwila BUILDING DIpVIsior CITY 0 TOP/ILA JUN 2 8 2011 TERMIPERMIT CENTER NAL CABINET DO- R 0 C B Y R - G ==▪ ==0 =8 R 0 V 0 8 E.V.P. 4 a541 -0- 542`Y- 543 -OL- SIGNAL POLE .1 -0 -A -O Eit1! 68L ESL 68 OV3H 03d =fA =MI [31 LIll Ern DTI tal usta LEU -I iF7>t IJ 0 •0 WWN 501 _9-B �+ 502 0= W- 1 :5-551 :e- BL _ow:764- w ,I1-653-161- _s- 0 c4 554 Via- w o; -GN ;:1,73:1-67f4- w 537�a BR 7.3,174-7*- W 9 _ 4N- S x•'561_ BL 34z R 6111 R :.2-61.3_13104-G -- Z5-81-4-141 B --- 4 :4 BIB 14N-W -- - --=- G 27 44-R --, "t>`-0 - (4 823 �It-G -24S8 0 626 :y W la 631 0- 74- -32 t- 534 .,- .7- 8359/ 641 -0 1:y1_442_1114 . ,C4 6AL3 ;..444_ X645 =� a R --YZt_ G_i22 -� r 0 .= 9 ..4772 R_` G a. w = 0 -,0_774;175 B ;11171_477 F R G ;= W 0 r_284,1r B F 7 €5 -E3/ R C.t'78z�E F w 0 "16_7B4? r B B -?. 811 '• w -ADO= r- B -+; 92. W 22.- ! B 823-?2 w'8241'l -B ( j W - B -' B1_ ,F 1. w�84 -2- -i B - i_1115l -W 1973152-..! B -1. W i B .111a6.7 -±A - w Byy_ is r- B - W B -1Z3: .J_w- o46n,', -B-. -P w 8aA921`z3 '-8 w -1. 884 e� -4 3 =r, ! :1 Jor ,N iT 1 E PUBLICWORKS DEPT. L . OCURT 4 .. - ENGINEERING- STREETS- WATER- SEWER-PARKS- BUILDING- �N�� TUKWILA URBAN ACCESS IMPROVEMENT PROJECT ,,,,.._ Sono , A� 135 p 196 SG11 / WIRING DIAGRAM SOUTHCENTER PARKWAY / DOUBLETREE ENTRANCE .4* .05 , 6CSG1NW1 mbE- 0 tD18HG 06 A00ENDUU 'WO= °O1° Mrs 4.. 08113/10 • SIGNAL SIGNAL PED. PED. HEAD HEAD HEAD HEAD 62 11 /61 49 68 ^N fITItO ^NI1Vt0 ^040 01 ^NAVY) wwwIt0 eQQQQmmmlmm 10 10 1010 10 mom„ 41, • ¢O1:)a)7,a:0002CCC )7,oms0som TERMINAL CABINET 125A I258I I25C1, 24A c I24BI I24CI 3 -2CS 10 O I I I I I W ¢000)i 0) 1 1 l N N 10 V 101010/0 10 010 t0 = 0(0000100 /0100010 JUNCTION BOX JUNCTION BOX PED POLE E 3A 0 Co W 0. ¢07,00) 1 1 1 1 SIGNAL POLE •3 11 0)0= 0a SIGNAL HEAD 81 '° I1 R- m ©682 0- C 683 G- 6841-8- 686 W- 10 E.V.P. 3 0— 1'532 SIGNAL HEAD 82 lq- 6BI-R- Y1' -0 - G1- -G - r8 -W - 682 683 684 686 m tap0.. u1 I . I e l CooaOa 0 R G w -0 -B PED. HEAD 88 PEO. HEAD 69 PEO. HEAD 88 SIGNAL HEAD 81.82 mm mm m Comm Comm mm N A 410 NA4N�Otp4N.- n T Y co co 1r11 n 1r n 1 r, ( u 1 n1 100 :00) 010 :00) 0000 II I II II II 11111111 ® SL- SIGNAL POLE •4 9 ra co y r mm a I 1 CD 1 PED POLE •4B JUNCTION BOX 153 1 238 23C 0. 52 / 22A 228 22C 51 )ziAI )2181 J21C PED POLE 2A JUNCTION BOX 5 -2CS 0 8 75T84 ° OPED POLE •4B P.P.B. 88 0 PED POLE •4A —0 -B JUNCTION BOX 764 P.P.B. 69 5-2CS I618I I61AI I11I SOUTHCENTER PARKWAY 5 —J 2 tal 0 W W 10 0 628 r--- I62AI 112( 4 MCDONALDS DRIVEWAY TERMINAL CABINET JUNCTION BOX 2 -2CS 638 "163AI 13 kipac a 0)00) 1 1 1 1 JUNCTION BOX 2 -2CS NI 648 164A1 JUNCTION BOX 658 CONTROLLER 551:_;e BL 35wak W 0 554140; w w Ss ° -BR 559 a W 659..8- S i� O it W s "4 get a- BL '-66-1761- R 1 15 BL -- SB4__M 0 �58SS�4i" -Y L5a8_ -BL 722-5-62 :oI-o —, (;,:30187113-y BL —. y = S2a Y - -- . 5X2_! BL (7R - -, 613 4o.0 47'4 r 614 *-B u 616_A -W! 7 El W 41_-812 -- B AZ-41-47N W -ALAI-LEA B roAR ' - w ITT 024 B�'tsri. W'._ = W 411, 842 r- B -851 t� '--W 40-052-ZS '.'.`j' 8 44-1.18-,-- -" W 4LBfi2_. = B - w Bed 8 is 671 :CI W- -8- a-7 W 974 ws B-re�a - w' - B -47-663-71 -`- W •' 884 :.. 6 .s N 01 04 = m000) °o 11 1 I N 8 JUNCTIO SOX 3 -2CS 7 -2CS 8 -2CS JUNCTION BOX 8 -2CS 1 -CC 3 -5C, 1 -3C5 TERMINAL CABINET JUNCTION BOX P.P.B. 48 1 I IU it ICI ¢ 00107,¢ o 0)010¢ 0s0m i ERG1E i HEEAD 48 E.V.P. SIGNAL -R -0 -G -8 _t rii! B 6,710 0- 513 Y- HEAD 42 641 642 43 644 646 MAST ARM R 6 W 0 B P.P.B. 48 PED. HEAD 48 SIGNAL POLE •2 N 0 ¢0001n aug D I 1 1 -9 o ra • aN 0)0 PED POLE •1A SIGNAL HEAD 41 - R- 641 R -0- -C- -8-644 - W- 646 642HY 643 C Zm000) N r x 1 1 1 1 0 N 68 '8•d'd - -8J 0 58L 68L 0 81. 310d 03d TO — CONTROLLER CABINET JUNCTION BOX 4 -3CS, 14 -5C, 19 -2C5, 3 -CC TERMINAL CABINET 0 p 622 22 21 G- 623 8 W126 R 651 --4652 .7 °r, • 653 Mt' B ;I.'" M- 656 R 781 G 782 W 787 O 87 T B 785 R x22 .0 W -723 D =724°-= G ioN NSP1 WWO a•x SIGNAL POLE •1 - 8- SBL -O e -8- ESL -dam E.V.P. 4 rip 0- Y- ':4 4k r rM- 111947, "1 X842 ;,'X 7.111)1_95.1._1,4 �e�e3i�1 74#196.1...1c) 1E-962 '01 ^O' 984 P_d .40 922 ':;,`X -17 .981. -10 902 ?:.14 y4C + yka r2 N W 0 CI OFTUKIMLA JUN 2 8 2011 co) ERMITCENT R 8s 68 OV3H '03d PUB C WORKS DEPT. -ENGI RING- STREETS WATER - SEWER - PARKS- BUILDING- 11110 10109 P40, 106 'INTB TUKWILA URBAN ACCESS IMPROVEMENT PROJECT SG11 / WIRING DIAGRAM SOUTHCENTER PARKWAY 1 DOUBLETREE ENTRANCE 1a Y uri a' 96B 96A 5 -2CS. 3 -5C JUNCTION BOX .--. -- 2 -2CS PED. HEAD 99 P.P.B. 89 t0 R G W- 0- B- SIGNAL HEAD 61.62 SIGNAL 111E.12 SIGNAL HEAD 81.82 SIGNAL HEAD A1.A2 -N P14 (0- N /1<to- N P1 P (0 NP1 <w btO ww (0- -- - 0{0(0(0(aaCaC www (0(0 (0ww (0w (0 (0(0 (0{0{0{0 (0 (0w 111111 Ill lo III 11111 nu 111rlrIo term lifnfnr in In zoo(s20oms zooms Qo0 (0(0 11!]!! I.IIIII/ TO CONTROLLER CABINET JUNCTION BOX 2-SC. 11 -2CS. 1 -3CS. l -CC SIGNAL POLE '4 TERMINAL CABINET PEO. POLE '3 0 u DERE N 1 1 1 1 u 10 ID I Egg E.V.P. 2 MAST ARM SIGNAL HEAD AI -R- 6A1 R -0- 6A2 Y - C- 6A3 - B- 6A4 - w- 6A6 G JUNCTION BOX r 3 -2C5 SIGNAL HEAD A2 - R- 6A1 R - 0 -G -6A3 G - 8- 6A4 - W - 6A6 -R -681 R 0- 682 Y - G- 683 - B- 684 -W- 686 SIGNAL HEAD 81 G -R -681 R -0- -C -683 G - 6- 684 - w- 686 SIGNAL HEAD 82 682 Y 642 Y — 0 Y —BL E.V.P. 3 _ ®It 2 SOUTHCENTER PARKWAY 8 A 6 STRANDER BLVD REVItVVEU Wh COMPLIANCE �CTH NFPA JUL 07 2011 City of .Tukwila BUILDING DIVISION PED. POLE '2A JUNCTION BOX PED. HEAD 08 3 -2CS. 2 -SC R -� W - 0- 6- 94B 2 -2CS 94A LIGHT POLE '2 N 0 1 I 1 I 20(00(0 PUBLIC WORKS DEPT. - ENGINEERING- STREETS WATER - SEINER - PARKS- BItlILDING- 81A 82A et 618 2 -2CS JUNCTION BOX JUNCTION 80X 638 1 -2CS JUNCTION BOX 1-2C5 JUNCTION 80X 648 BIB ALA IMB1 828 A2A —\ A28 JUNCTION BOX = CO 0 0 73 1 1 1 0 r 01 m ro SIGNAL POLE •I PED POLE '1A JUNCTION 80X 183A owsw 80 doom *Wad -q �1= a 18 leak ro 838 A3A a1NTB A3B 0 O u z 1 -2CS 0 4 -2CS —R — G — W — 0 — 8 658 PEO. HEAD 28 P.P.B. 28 E.Y.P. 4 0 Y 4 MO BL TERMINAL CABINET Rg 62; 0= 622 <a°: -G'623 _R2 _ 6 =_ 624 _ W 626 R 721 G= 722 O.,' W- 723 c 4 -2CS 725 JUNCTION BOX 92A 92B 92C 920 CONTROU-EF1 2 1 1 1 4 BL 52 =0 W _ �► 0 3Sf I W 5.50" ;_a -ON W BR 36_s-W E: 5.9_ . S . .0 — 60-W r` J J BL R x586 :a`; -0 - ... -. - -, e8 y - -• 589 -` BL _. -. 590 10 -0 --- 91yiY --! �S 592 r BL 1 `,%:_6]L. is -R 0.632_AW -0 L 6]1L� G Ea 611 -W -B ; f: 81 :. W '- BT2Ts0— 62 _12.4 i-B ---:' ts.125_ . W ---- -- =..631 r -R- e3i 034 B - -- Sz_41J!, 0042.. 644 rev 6 6�tta 552 k ;._8.53 : D1.70 5i kS 6g-1 TN -R --_, .ATE -0 - ky:S64j.8 ._.- r6e6 2l 3 get iM -0 3. BG k3-78K-111-18 -_ -4 BAU -R 3.A3 HM-G 584 F 8 Y4 6A8r-.W ..7.....110- s-a y_ K 1a - TUKWILA URBAN ACCESS IMPROVEMENT PROJECT 10 - B -?.! 921 4- W •'`$22 B i W -9ti 924 =5. 8 -Lr 925.tss W i e W - 8 —ALIAT _D: -1- W -4 964 Kk -1.' 971 101 -1:: 2- -B 984 lO 407 1c9 AS$41SLA omi JUN 2 8 2011 ci) PERMIT CENTER SG12 / WIRING DIAGRAM SOUTHCENTER PARKWAY 1 STRANDER BLVD CO revisions 136 196 � fie m SOSGW002 wis m. 89t13N0 1 r PED. HEAD 39 FA1 735 P.P.B. 39 JUNCTION BOX R - - W 0 - LIGHT POLE *3 0 co z 0 z 0 JUNCTION BOX all-octet 0 0 45 44 42 41 95A 953 JUNCTION BOX PED HEAD 38 P.P.B. 38 SOUTHCENTER PARKWAY 5 2 JUNCTION BOX 0 R PED. POLE '2 PUBLIC WORKS DEPT. -ENGINEERING-STREETS-WATER-SEWER-PARICS-BUILDING- 4 KLICKITAT DRIVE E.V.P. 1 511 512 513 -0 - 7 - -84- SIGNAL HEAD 81 Fa, 681 ..0-R r - -8 - 11.031111 dlawa snood Jp salsa CSC 5ws, JOS 682 683 684 686 REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC 1 JUL 07 2011 i City of Tukwila BUILDING DIVISIQN TERMINAL CABINET 2-3C5. 4-5C, 1-CC SIGNAL HEAD 41 R - 641 -R 0 - G 643 -G - 646 -5 - 0 z HNTB SIGNAL POLE •1 1 1 1 1 CO 0 0 72 11011 tibia, MI Ut 1 1 1 1 1 2 CD 0 0 72 griRR 6661321 117, ai 9 686 :6 643 R _5624 w= 6666662424444642: 0= ..azi 622 31.37! 0= 623 gR 5/ 6 4 1,9= 6 65266 g:":..M653 54E! S--4- .7'.. an r rn= an C11-101 CO 0 0 b. 2 0. X P1 0 CONTROLLER - R 417-12111 G .5147-fig= W 0 9 44-7157.7.5 f-;77.55 17* BL 70:27k• w iT5r $.317.1* 0 W 7 56L- BR W S W 8L if;LaLito:- 9 581...Lor 0 y S83-BL 3!6- 0 ---, .;113L565_Y K1586 1-8L --1 kfiff8=4;-y ---4 BL 5913_:47 0 - •- -- =5.11:1*-`r — -- Z__769:217#1 BL L',Fgafflf-o 62 42,3_,A,-0 zr-g24 rig-a w ar:1117-t- R.7-"a2 ? 634 4- Ur. 836-744- R51-64Lick- R 7:4-64-1-W- 0 G 73.1 644 B k..71-tr-46 W 6.;51:41 R 6523�0 TjT-B 66_1_46-W Qt. Waif 664 44- uratirre, ---H TUKWILA URBAN ACCESS IMPROVEMENT PROJECT 8 -04 981 44 W B -10=0:03:33 RECEIVE CITY OF TUKVVI JUN 2 8 2011 PERMIT CENTENO. SG13 / WIRING DIAGRAM SOUTHCENTER PARKWAY / KLICKITAT dab 137N ... 196, mrs£9:9091003 dab MI3,111 4 1 1 42 4 TO CONTROLLER CABINET 8-2CS, 5-3CS, 8-5C, 4-CC 4-5C. 3-3CS, 4-CC SIGNAL HEAD 43 - R- 641 - 0- -6- - 8- - w- 642 643 644 646 E.V.P. IA rah SIGNAL HEAD 31 SIGNAL HEAD 32 HEVIEWLU 1-01-1 COMPLIANCE WITH. NFPA 70 - NEC JUL 07 2011 City of Tukwila BUILDING DIVISION 2-3CS. 4-5C. 1-CC 0 631 R - 07632 Y -G 633 G - 87 634 - w- 636 MAST ARM 010 0 2,114 41 N el, .2c 7 1 - R- 631 -0- R 632 Y 633 HG G- - g- 634 - 636 ci E.V.P. 3 —y —8 JUNCTION BOX TERMINAL CABINET 6-2C5 I 61 C JUNCTION BOX 6- 2CS JUNCTION BOX 3 2CS 62C r- 618 11 SOUTHCENTER PARKWAY 2 NORDSTROM DRIVEWAY 628 12 4 63C 638 13 JUNCTION BOX 3-2CS 64C 648 14 JUNCTION BOX 65C I 658 15 I 8 6 JUNCTION BOX as. as a,ce ca o ID EEtmigam SIGNAL HEAD 41.42 SIGNAL POLE n SIGNAL HEAD 42 - R - -8 -w E.V.P. 1 — 0 —Y — BL 511 512 513 - 641 NR - 644 646 642 Y 643H6 SIGNAL HEAD 41 - R- 641 R 0--i 642 Y Lai 1X031.003 MAST ARM _ 8- - 8- 644 - V- 646 1-3CS. 2-5C. 1-CC maa Zaggi =WOO . M M N IV IV W UI r 0 I- x 11 1 m acasoom 1 1 1 1 41 TERMINAL CABINET SIGNAL POLE .1 ID co0 01 7, CONTROLLER 1 w- - KEW74,BL • w 553 , 0 — ■<•'-aW15E w • GN W BR 17-5lCTLF- w Sar ws a:14E4- BL 15#27_141- R t., sat 4-0 rEartyp--y 11-583-14- BL 27:513-4..74,- 0 ''t...3_51375 "( BL --L F_':t.187__Atro Kel_SIRTaf-Y BL E5_173-9t 0 K5759J-Twy Y aL R F.176.F2:4--. 0 .-7-6F3-7-0-O ra_821. JA-R LI.1122_1_81-0 —4 1:111 826 lw-W 631 At-. 633 IF- KT-631-811i- bl 636 IV- )I 641 Sf R ni 642 16I- 0 zw-sTrnet- G 01 644 i4k- W rgi_651 fg-1 cr576-5TW- Mar_IA-. 654 4,- 1:31-8WTICk- R jV ,45; 722f1 w o 41-7-1-4-Z3 -- 8 407'725 B -*==3 i • A. a7 KL.q w 491-1124-R, B W 882 C1 B 44170,-13,v W-114Liga_g -19 911 C- ;!j_ 711K 922_ 681 Na.-R Lti 682 A-0 iT-r6r83 G --1 rrga-r#:-W FJ c140$E4VALImi JUN 2 8 Zoil r PERMIT CENTER'''. . , . . - .. i . i . PUBLIC WORKS DEPT. . ... ENGINEEFIING•STREETS•WATEM•SEINER•PARKS•MUILDING.• ....._ , [ t a Q•INTB TUKVVILA URBAN ACCESS IMPROVEMENT PROJECT Ss Nv ■ - 4 4.117.1 all RWP '138) "2%."' ,196 RiR1 0C SG14 / WIRING DIAGRAM SOUTHCENTER PARKWAY / MALL ENTRANCE Mi .fr As no SCSGWDDI Mines A MON ADDENDUM a scab, wTs dabs 8913110 TO CONTROLLER CABINET 8 -2CS, 5 -3C5. 8 -5C, 4 -CC 42 41 4 -5C. 3 -3CS. 4 -CC SHEEAD 11 H SIGNAL HEAD -.Nn r.d•+N Ip id la id u to ulioi 1110 1 1 If11111(1 n e ¢ 000Ii S 0002, 00001 ¢00' mZ SIGNAL SIGNAL HEAD HEAD �61.62 �`.3311.332I Wfmin fm IU 1�W4 q 2-3C5, 4 -5C. 1 -CC 11/ '1x41 SIGNAL POLE d3‘ n 1 1 1 1 1 ivv d n 440.OI,ON to to a 1 1 1 1 1 6 0 0 CI 3, a 0 > 0 X an to 10 SIGNAL HEAD 43 -R-641 R -0- -G -643 G -8- 644 -W -646 642 Y SIGNAL HEAD 31 R- 631 R 0- G- 5- 634 W- 636 632 Y 633 G E.Y.P. IA — 0 Y --BL 51 ®1t SIGNAL HEAD 32 -R-1-311 - {{{R��� -0 632HY -C -633 G -B- 634 -11/- 636 MAST ARM 2 0 0 0 30 E.V.P. 3 — 0 —Y ---BL ®, 6 -2C5 JUNCTION BOX 6 -2CS JUNCTION BOX 3 2CS 61C 1616 / 11 SOUTHCENTER PARKWAY 2 NCTION BOX TERMINAL CABINET U�GGC 0C'ttI323,[Ca 0610600 NiECil:iga2g. SIGNAL HEAD PEO. HEAD 29 SIGNAL POLE .2 0 0 Z 62C 628 4 L- r-- 6 163C 638 13 JUNCTION BOX 3 -26S 64B 14 JUNCTION 80X 1 65C 6581 CONTROLLER i "5Qfvi:B • - -- R2mE-w - - . -. BL w O 554_x= w • GN 5sr - w BR `s2 37 Via- - aja—ia- w 'za_= s 6.o_±f W Ede=-$ fl' - EL ter BL -w 6; :sit 1i 4-R -- ftfi Aw -- 01 01 al N N N N a a, N 1 1 1 1 = CO 0 0 A 1 1 1 1 In 0 X 0 Z m w 4077. Off -g �! - ---,7' ;o3, 16'.11 :g 1 8 SIGNAL HEAD 42 SIGNAL HEAD 41 E.Y.P. 1 - R- 641 R -0 -511 -0- —Y -512 D -G- -BL 513 -8- 644 -W- 646 642HY 643HG at N O MAST ARM R- 641 R O- 642 Y G- 643 8- 644 W- 646 G 1 -3CS, 2 -5C. 1 -CC JUNCTION BOX 1 1 1 1 1 u 1 TERMINAL CABINET SIGNAL POLE '1 0000A x O R_ 621 0= G=- B= WE R G W. 8 5 622 623 624 626 723 724 . aalz 3,o N 2T WWN ax RECEIVF,p_ r1 CITY OFTUICVnLA JUN 2 8 2011 PERMIT CEIdTERCIIII PUBLIC WORKS DEPT. -ENGINEERING-STREETS-WATER-SEWER-PARKS-BUILDING- oaA1� 00 del NIL/ ctodad 1.4.9 06 CAA as MAW 'INTB TUKWILA URBAN ACCESS IMPROVEMENT PROJECT SG14 / WIRING DIAGRAM SOUTHCENTER PARKWAY / MALL ENTRANCE • • City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director ANNETTE O'HARE PO BOX 9169 COVINGTON WA 98042 RE: Permit No. EL11 -0568 D B E ELECTRIC, INC. Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 03/21/2012. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 03/21/2012, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, ifer Marshall it Technician File: Permit File No. EL11 -0568 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 "ERNI COORD COPY• PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL11 -0568 DATE: 06/28/11 PROJECT NAME: DBE ELECTRIC LOCATION: SW CORNER OFSOUTHCENTER PY & KLICKITAT X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: Bull rng Divis on Ol, I Public Works Fire Prevention Structural Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete 1K Incomplete n DUE DATE: 06/30/11 Not Applicable n Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 07/28/11 Approved ❑ Approved with Conditions IJ Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 Contractors or Tradespeople linter Friendly Page 1 Electrical Contractor A business licensed by Lal to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company DBE ELECTRIC INC 2538878089 Po Box 9169 Kent WA 98042 King Corporation DBE ELECTRIC INC UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 602952513 Active DBEELEI912PM Electrical Contractor 10/14/2009 10/14/2011 General Unused Electrical Administrator INFORMATION License GUTHMMT924PZ Name GUTHMILLER, MARY T Status Active Business Owner Information Name Role Effective Date Expiration Date LAWRENCE GLOSSER AHLERS CRESS Agent 10/14/2009 GUTHMILLER, MARY T President 10/14/2009 GUTHMILLER, MARY T Secretary 10/14/2009 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 American Contractors Indem CO 100098755 09/28/2009 Until Cancelled $4,000.00 10/14/2009 Assignment of Savings Information No records found for the previous 6 year period Insurance Information No records found for the previous 6 year period Summons /Complaint Information Summons and Complaints are not filed with the department for this contractor type Warrant Information Warrants are not filed with the department for this contractor type https: // fortress .wa.gov /lni/bbip /Print.aspx 07/28/2011