Loading...
HomeMy WebLinkAboutPermit EL11-0650 - JIMMY JOHN'SJIMMY JOHN'S 16864 SOUTHCENTER PY EL1 1 -0650 City *Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov Parcel No.: 2623049129 Address: 16864 SOUTHCENTER PY TUKW Project Name: JIMMY JOHN'S ELECTRICAL PERMIT Permit Number: EL11 -0650 Issue Date: 08/12/2011 Permit Expires On: 02/08/2012 Owner: Name: PARKWAY SQUARE Address: C/0 ROSEN PROPERTIES , PO BOX 5003 Contact Person: Name: MITCH HART Address: 234 - 5 AV S , EDMONDS WA Contractor: Name: R -C TRUE LINE CORPORATION Address: 15321 105 AV CT E , PUYALLUP WA Contractor License No: RCTRULC038QG Phone: 425 774 -4185 Phone: 253 845 -8775 Expiration Date: 11/07/2011 DESCRIPTION OF WORK: ADD LIGHTS AND OUTLETS PER PLAN Value of Electrical: NRES: $10,000.00 RES: $0.00 Type of Fire Protection: SPRINKLERS Electrical service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: Fees Collected: National Electrical Code Edition: $330.63 2008 Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of construction o Signature: ermit , o erfo %' a no3.pregsum e of work. I e authority to violate or cancel the provisions of any other state or local laws regulating thorized to sign and obtain this electrical permit. Print Name: Date: 69-42 (� This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/10 EL11 -0650 Printed: 08 -12 -2011 IIII II PERMIT CONDITIONS Permit No. EL11 -0650 * *ELECTRICAL ** 1: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 2: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 3: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 4: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 5: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 6: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. doc: EL -4/10 EL 11 -0650 Printed: 08 -12 -2011 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.qov • Electrical Permit No. .eot .Project No. (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION.. King Co Assessor's Tax No.: 262304/9/37 Site Address: / & t..JAy Sn, .sA/z£ -co.nHC ;.n(e ft: AV Suite Number: Floor: 1 Tenant Name: It AA ,r•y NN'.1" New Tenant: [r Yes ❑..No Property Owners Name: .5.4.vnt.,)i l SC L.C. C Mailing Address: /1/ E 5(FFE4So", Avi• SiL CJAPRZU /LLE City State 69zya Zip CONTACT PERSON — Who contact when your permit is ready to be issued �3•. Name: /s ,7c• 4 ,,z-r - td, ��e5c (�,�,�T2vcT.o.✓ Mailing Address: 7.3'7 5.1.** 4va E -Mail Address: "11174.--/ e ia,lcex�A/lr�i�vc7ien.�pM Day Telephone: &-2S- 4Ae^or-lA s City Fax Number: '%f - 771 5/465 19.< State Zip 771 -z(a ELECTRICAL CONTRACTOR INFORMATION Company Name: 713 Mailing Address: City Day Telephone: Fax Number: Expiration Date: Contact Person: E -Mail Address: Contractor Registration Number: State Zip Valuation of Project (contractor's bid price): 40005 • °-= Scope of Work (please provide detailed information): / b n✓770 11- PE4 PL4 1J Will service be altered? ❑ Yes I /No Type of Use: Q 5R. , iL h(tIP Type of work: ❑ New ❑ Addition ❑ Low Voltage ❑ Generator Property Served by: E' Puget Sound Energy ❑ Seattle City Light Adding more than 50 amps? ❑ Yes Er ❑ Service Change ❑ Fire Alarm HAApplications\Porms- Applications On Line\2010 Applications \7 -2010 - Electrical Permit Application.doc bh Page 1 of 2 ❑ Remodel ❑ Telecommunication "Tenant Improvement ❑ Temporary Service RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $152.85 (including an attached garage) ❑ Garages, pools, spas and outbuildings $81.90 ea ❑ Low voltage systems (alarm, furnace thermostat) $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $81.90 (no added/altered circuits) ❑ Service change with added/altered circuits $81.90 number of added circuits $11.55 ea ❑ Circuits added/altered without service change $54.60 (up to 5 circuits) ❑ Circuits added/altered without service change $54.60 (6 or more circuits) $7.65 ea ❑ Meter /mast repair $68.25 ❑ Low voltage systems $59.85 (alarm, furnace thermostat) MULTI - FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $63.00 ❑ Temporary service (generator) $78.75 ❑ Manufactured/mobile home service $84.00 (excluding garage or outbuilding) ❑ Carnivals $78.75 Number of concessions $10.50 ea PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: Print Name: .a0/2.1 _ )Meet Mailing Address: /l/ 1 ,1ifF,E.4TenJ .-5'T£. 1"/ Date Application Accepted: I I f " Date: 7/1/1 Day Telephone: 61.1) 5(9 -csdS thPER.1 e_cE City Date Application Expires: State Zip Staff Initials: H_\Applications \Forms - Applications On Line '1010 Apphcations17 -2010 - Electrical Permit Application doc bh Page 2 of 2 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: / /www.TukwilaWA.gov RECEIPT Parcel No.: 2623049129 Permit Number: EL11 -0650 Address: 16864 SOUTHCENTER PY TUKW Status: APPROVED Suite No: Applied Date: 07/19/2011 Applicant: JIMMY JOHN'S Issue Date: Receipt No.: RI 1 -01750 Payment Amount: $301.75 Initials: WER Payment Date: 08/12/2011 09:50 AM User ID: 1655 Balance: $0.00 Payee: ROBERT RAU TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd MC Authorization No. B55160 ACCOUNT ITEM LIST: Description 301.75 Account Code Current Pmts ELECTRICAL PERMIT - NONR ELECTRICAL PLAN - NONRES 000.322.101.00.00 264.50 000.345.832.00.00 37.25 Total: $301.75 doc: Receipt -06 Printed: 08 -12 -2011 of Tukwila. Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: httto : //www. ci. tukw ila. wa. us SET RECEIPT RECEIPT NO: R11 -01504 Initials: JEM Payment Date: 07/19/2011 User ID: 1165 Total Payment: 1,462.73 Payee: CHIPMAN DESIGN ARCHITECTURE INC. SET ID: S000001531 SET NAME: JIMMY JOHN'S SET TRANSACTIONS: Set Member Amount D11 -237 1,283.68 EL11 -0650 28.88 M11 -100 73.46 PG11 -107 76.71 TOTAL: 1,283.68 TRANSACTION LIST: Type Method Description Amount Payment Check 22500 1,462.73 TOTAL: 1,462.73 ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - NONRES ELECTRICAL PLAN - NONRES PLAN CHECK - NONRES 000.322.100 000.345.832.00.0 000.345.830 TOTAL: 58.82 28.88 1,375.03 1,462.73 INSPECTION NO. INSPECTION RECORD Retain a copy with permit DUI - �65� PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 it,. (206) 431 -3 Permit Inspection Request Line (206) 431 -2451 Project: kM joi-1j Type of Inspection: il Address: / / � n . Special Instructions: Date Called: Date Wanted: . 2jav /0 /2.— Requester: Phone No: Approved per applicable codes. E Corrections required prior to approval. COMMENTS: Inspector: Date: i 0/ Z b i REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. 3 INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. • CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 vc., (206) 431 -36 Permit Inspection Request Line (206) 431 -2451 Project: .� • Address: 16Uf$c -i% Special Instructions: Type of Inspection: Gov Date Called: Date Wanted: Requester: Phone No: ❑ Approved per applicable codes. Corrections required prior to approval. COMMENTS: k vc. t h4T tidal -Pa tii War 145941 ' oR StAvi.r sos LOCAL but INASe. Pc41), trIA J ki - 14 Obicterc LocienokkF O Q - 0 tc at_ ciAk&ir cmazillJil Nixic-Fol-c likl 601440 !tr. lb D6\ARE 10 50:76 - f►s-mwd 6Itihnv, 14 PAAJa. _ ❑ REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit P RMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 a (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: 7O 5 Type of Inspection: �� Address: �j/ �t Date Called: Special Instructions: Date Wanted: . /0 v /7 m: Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS • etitAAki_S tAi ivai 3sgi+toonj Inspector: Date: /0/01/1/ • • E REINSPECTION FEE REQUIRE. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Cr t . A� Retain a copy with permit ‘-14 O INSPECTION NO. P RMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -36 Permit Inspection Request Line (206) 431 -2451 Project: •_ b( +41� Type of Inspection: 7003 Address: 14814 s -C- q Date Called: Special Instructions. Date Wanted:. (� 1 / p.m Requester: Phone No: Approved per applicable codes. a Corrections required prior to approval. OMMENTS: C/ -r ELI. Wd1n/J5 , /krehA DSr 'varf Inspector: 'Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. •PERMIr COORD COPIIA PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL11 -0650 DATE: 07/19/11 PROJECT NAME: JIMMY JOHN'S SITE ADDRESS: 16864 SOUTHCENTER PY X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # after Permit Issued DEPARTMENT S� Building ,Davis V 1`I Bullding Division Public Works Fire Prevention Structural Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 07/21/11 Not Applicable n Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 08 /18 /11 Approved Approved with Conditions 14 Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 Contractors or Tradespeople Pry^ er Friendly Page • Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company R -C TRUE LINE CORPORATION 2538458875 15321 105Th Ave Ct E Puyallup WA 98374 Pierce Corporation UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 601828382 Active RCTRULC038QG Electrical Contractor 11/7/1997 11/7/2011 General Unused Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status TRUEL "035KH TRU LINE LINE E Electrical Contractor General Unused 5/8/1997 5/8/1999 Archived Master Electrician INFORMATION License RAU *RRH967C3 Name RAU, ROBERT H Status Active Business Owner Information Name Role Effective Date Expiration Date RAU, ROBERT H Violation Amount 01/01/1980 8/10/2009 RAU, CARLOTTA ELECTRICAL CITATION 01/01/1980 $250.00 RAU, ROBERT H Agent 01/01/1980 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 DEVELOPERS SURETY & INDEM CO 445594C 11/01/1997 Until Cancelled $4,000.00 06/15/2001 Assignment of Savings Information No records found for the previous 6 year period Insurance Information No records found for the previous 6 year period Summons /Complaint Information Summons and Complaints are not filed with the department for this contractor type Warrant Information Warrants are not filed with the department for this contractor type Infractions /Citations Information Infraction / Citation Date RCW Code Type Status Violation Amount EREEB00414 8/10/2009 19.28.161 RCW ELECTRICAL CITATION Satisfied $250.00 https: // fortress .wa.gov /lni/bbip/Print.aspx 08/12/2011 EQUIPMENT POWER SCHEDULE co . 1. ELECTRICAL CONTRACTOR SHALL VERIFY THE EXACT LOCATION, HEIGHT AND ELECTRICAL CHARACTERISTICS OF ALL EQUIPMENT PRIOR TO ROOGH -IN WITH KITCHEN EQUIPMENT SUPPLIER, AND KITCHEN ROUGH -IN DRAWINGS. 2. ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL REQUIRED LOCAL DISCONNECTS AND SPECIAL ENCLOSURES (I.E, NEMA 3R, STAINLESS STEEL, ETC.) PER LOCAL CODE. 3. ELECTRICAL CONTRACTOR SHALL CHECK ROTATION OF ALL THREE PHASE MOTORS AND CORRECT ROTATION IF REVERSED. 4. ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL CIRCUIT BREAKER LOCK -ON DEVICES FOR ALL BRANCH_ aRCUITS SERVING REFRIGERATION .EQUIPMENT. 5. ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL FINAL EQUIPMENT POWER AND CONTROL TERMINATIONS. 6. ELECTRICAL COMPONENTS FURNISHED LOOSE BY KITCHEN EQUIPMENT SUPPLIER (OR BY THE ELECTRICAL CONTRACTOR AS NOTED) SHALL BE MOUNTED AND WIRED BY THE ELECTRICAL CONTRACTOR. 7. ALL FLEXIBLE CONDUIT EQUIPMENT CONNECTIONS SHALL BE: "SEAL TIGHT". TAG DESCRIPTION VOLTAGE PHASE LOAD (FLA) FROM PANEL aRCUIT NO. WIRE & CONDUIT • TYPE OF . CONNECTION MOUNTING HEIGHT BREAKER REMARKS E -3 P.O.S. SYSTEM 120V/10 4.1A A 12 2 #12, 3/4 "C 1 #12 GRD DUPLEX I.G. RECEPTACLE IN CASEWORK 1P, 20A LOCATE RECEPTACLE WITHIN 4' -0" OF P.O.S. STATION AND APC UPS E -8 ICE/DRINK DISPENSER 120V/10 4A A 26,28 2 in 3/4 "C RECEPTACLE 12" A.F.F. 1P, 20A CASEWORK RECEPTACLE WITHIN E -13 REFRIGERATED PREP TABLE 120/V10 12.8A A 8 2#12, 3/4 "C DUPLEX RECEPTACLE • 12' A.F.F. 1P, 20A 0.48 WALK IN LIGHTS /DEFROST A 10 0.48 GFI E -15 OVEN/PROOFER 208V/30 18.4A A 2,4,6 4 18 GRD., 3/4 • C 60A /3P DISCONNECT +18 A.F.F. 3P. 50A UNIT REQUIRES 3 HOT, 1 NEUTRAL AND 1 GROUND E -17 ICE MAKER (WATER COOLED) 208V/10 8.1A A 33,35 D 2'3/4 #1 J-BOX 72" A.F.F. 2P, 20A 1 E -23 WALK -IN FREEZER COMPRESSOR 208V/10 8.8A A 1,3 3 #12, 1#12 GRD., 3/4 "C. 30A /2P NF DISCONNECT VERIFY 2P, 20A INTERLOCK WITH FREEZER EVAPORATOR. VERIFY LOCATION WITH INSTALLER E -23a WALK -IN COOLER COMPRESSOR 208V/10 7.2A A . 57 , 3 #12, 1 #12 GRD., 3/4 C. 30A /2P NF DISCONNECT . VERIFY . 2P, 20A INTERLOCK WITH COOLER EVAPORATOR. VERIFY LOCATION WITH INSTALLER E -23bWALK -IN FREEZER LIGHTS, EVAPORATOR, DOOR HTR. 120V 10 / 1.97A A 9 2 12, 3/4 "C # J-BOX VERIFY 1P, 20A PROVIDE LOCAL DISCONNECT FOR EVAPORATOR E -27 SLICER 120V/10 6.0A A 14 2#12, 3/4 "C DUPLEX RECEPTACLE 44" A.F.F. 1P, 20A 20 • 1 1.20 1.20 POWER - EXTERIOR SIGNAGE 20 1 1.20. SERVIC AZlra( I,..y I E VOLTAGE: 208Y/120V 0 0 0 0 0 0 LTG EQP HTG PANEL 'A' POWER RISER FLAG NOTES: EXISTING LANDLORD DISTRIBUTION /SWITCHGEAR. EXISTING METER AND 200A 3P BREAKER. NO CHANGE EXISTING 2 1/2" CONDUIT WITH (4) #250kCMIL AL THWN & (1) #6 CU THWN EGC. NO CHANGE EXISTING 200A, MAIN LUG ONLY, 208Y/120V, 3P4W, 42 SPACE PANELBOARD. RECONFIGURE BRANCH CIRCUITS PER PANEL SCHEDULE. EXISTING PANELBOARD LOCATION: BACKROOM PANEL A LOAD DISTRIBUTION FEED FROM: LANDLORD METER CENTER . FEEDER: 200 AMP 3P4W + GND PH REC LTG EQP HTG KIT CKT DESCRIPTION PH AMP POLE LOAD kVA AMP: 200 VOLTS: 208/120 PHASE: 3 WIRE: • 4 BUS TYPE: CU A:I.C.: • 10K M.L.O.: XXX MAIN CB: FLUSH: SURFACE: XXX GND. BAR: XXX ISO GND: 200% NEU: FEED THRU: .DBL LUG: TOP FEED: BTM FEED: PANEL T.C.L. LOAD (kVA) A B C A B C A 8 C A B C A B C A B C A B C WH -1 WATER HEATER 208V/30 50 FLA 1.24 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 . 31 33 . 35 37 39 41 WALK IN FREEZER COMPRESSOR O w D O w D O w D O w D 0 w D •: o w 9' -O w>O wDO w DOw D O w D O w D 20 2 1.24 EXHAUST FAN 120V/10 1.1 FLA 1.24 - - - 1.24 0.84 WALK IN COOLER COMPRESSOR 20 2 0.84 0.84 - - - 0.84 0.48 WALK IN LIGHTS /DEFROST 20 1 0.48 0.80 POWER - EXHAUST FANS EF -1, DAMPER 20 1 0.80 0.20 POWER - CEILING FANS 20 1 0.20. SPARE 20 1 0.98 •. LIGHTING - DINING TRACK VIA CURRENT LIMITER ' 20 1 0,98 1.24 LIGHTING - FOOD AREA TROFFERS, SIGN LTS 20 • 1 124 0.14 0.20 LIGHTING /FANS' - BATHROOMS . 20 1 0.34 0.36 RECEPTACLES -SHOW WINDOWS 20 1 0.36 1.20 POWER - EXTERIOR SIGNAGE 20 • 1 1.20 1.20 POWER - EXTERIOR SIGNAGE 20 1 1.20. 0.20 RECEPTACLE - JIMMY CLOCK 20 1 0.20 1.00 RECEPTACLES - NEON SIGNS 20 1 1.00 0.84 ICE MACHINE 20 2 0.84 0.84 - - - 0.84 6.00 WATER HEATER 60 3 6.00 6.00 - - 6.00 6.00 - 50 - 3 6.00 2.20 A B C A B C A B C A B C A 6 C A B C A 8 C 2:20 2 4 6 8 10 12 14 16 18 20 22 24 26 .. 28 30 32 34 38 38 40 42 BREAD OVEN /PROOFER 2.20 - - 2.20 2.20 - 2.20 REC 3.2 LTG 6.1 EQP 19.0' HTG 18.0 KIT . 17.7 1.53 REFRIGERATED PREP TABLE 20GFI 1 1.53 1.53 REFRIGERATED PREP TABLE 20GFI 1 1.53 0.64 RECEPTACLES - P.O.S. SYSTEM 20GFI 1 0.54 0.72 SLICER 20GFI 1 . 0.72 0.36 RECEPTACLES - PHONE BANK 20GFI 1 0.36 TOTAL 62.0 ' 0.18 RECEPTACLES - CONSOLE TABLES 20GFI 1 0.18 . FEEDER T.C.L. LOAD (kVA) 0.64 RECEPTACLES - MAKE UP LINE (PRINTERS) 20GFI 1 0.54 0.72 RECEPTACLES - MGR DESK 200FI 1 0.72 0.18 RECEPTACLE - LOWELL CABINET /RACK 20GFI 1 0.18 REC 3.2 LTG 7.7 EQP 19.0 HTG 16.0 KIT 17.7 0.50 RECEPTACLES - ICE /DRINK DISPENSER 20GFI 1 0.50 0.50 RECEPTACLES - ICE/DRINK DISPENSER 200F1 1 0.50 0.36 RECEPTACLES - ROOFTOP CD HVAC UNITS 20 1 0.36 2.30 HVAC UNIT - RTU -1 30 3 2.30 2.30 - - 2.30 TOTAL 63.6 2.30 - - 2.30 FEEDER DEMAND kVA 57.4 AMPERES 159.4 3.02 HVAC UNIT - RTU -2 40 3 3.02 3.02 - - - 3.02 3.02 - - - 3.02 :::X•••:•:::::•:..::::::•:•:•:',:•:•:::::•:• •;•: •:•. •:•:•: ::•:. Manutacturer/Type: Circuit Breaker Type: Remarks :. • = PROVIDE BREAKER HANDLE LOCK , RECEPTACLES (1ST IOWA): RECEPTACLES OVER 10KVA 3FF LIGHTING: EQUIPMENT: HEATING: KITCHEN: 25% OF LARGEST MOTOR: CONNECTED: CONNECTED: SERVICE 3.2 . 6.1 19.0 16.0 17.7 kVA kVA kVA kVA kVA kVA kVA kVA Amps CALCULATIONS 100% 32 kVA 50% kVA 125% 7.7 kVA 100% 19.0 kVA 100% 18.0 kVA 65% 11.5 kVA 25% kVA A 0.5 338 6.0 5.3 7.0 B 1.1 1.3 8.2 5.3 6.8 C 1.6 1.2 6.8 5.3 3.9 ::::.....„.....:,,...:**„..........% : • •'.•''•'' • •'''•:: •:' • • :•:•... -19.0• •':•'''•:''•'' t••;_•...:A•O••••••••• • -• 16.0 •'•:'• 17.7 T 3.2 8.1 TOTAL CONNECTED LOAD PER PHASE: 62.0 172.3 LOAD DEMAND: 57.4 kVA DEMAND: 159.4 Amperes PHASE A: 22.5 kVA PHASE 6: 20.7 kVA PHASE C: ., 18.8 kVA MECHANICAL. EQUIPMENT POWER SCHEDULE TAG DESCRIPTION VOLTAGE/ PHASE Kw/HP /FLA REMARKS AC -2 ROOFTOP HVAC UNIT 208V/30 19.2 FLA EXISTING UNIT/DISCONNECT. NO CHANGE AC -1 ROOFTOP HVAC UNIT 208V/30 25.2 FLA . NEW UNIT. PROVIDE 30A 3P 240V DISCONNECT AND CIRCUIT TO PANEL AS SHOWN WH -1 WATER HEATER 208V/30 50 FLA 18kW ELECTRIC HEATER EF -1 EXHAUST FAN 120V/10 1/4 HP EF -2 EXHAUST FAN 120V/10 1.1 FLA EF -3 EXHAUST FAN 120V/10 1.1 FLA MECHANICAL EQUIPMENT POWER SCHEDULE NOTES. 1. ELECTRICAL CONTRACTOR SHALL REFER TO ALL MECHANICAL PLUMBING AND ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS AND CHARACTERISTICS OF ALL EQUIPMENT LISTED BELOW. ANY MODIFICATION AND /OR ADDITIONAL WORK NECESSARY SHALL BE INCLUDED IN THE BASE BID. 2. ELECTRICAL CONTRACTOR SHALL CHECK THE ROTATION OF ALL THREE PHASE MOTORS AND CORRECT THE ROTATION IF REVERSED. 3. ALL TEMPERATURE CONTROL AND INTERLOCK WIRING SHALL BE BY HVAC CONTRACTOR UNLESS NOTED OTHERWISE. 4. ELECTRICAL CONTRACTOR SHALL SUBMIT EIGHT (8) SETS OF CATALOG CUTS FOR ALL SCHEDULED EQUIPMENT FURNISHED BY THIS CONTRACTOR FOR ARCHITECT/ENGINEER REVIEW. 5. ELECTRICAL CONTRACTOR SHALL COORDINATE THE ROUTING OF POWER WIRING TO. ROOF - MOUNTED EQUIPMENT WITH MECHANICAL PIPE CURB ASSEMBLY. NO SEPARATE ROOF PENETRATIONS WILL BE PERMITTED. 6. ELECTRICAL CONTRACTOR SHALL FURNISH AND WIRE DUCT SMOKE DETECTORS IN THE RETURN AIR PLENUM AND A FAN SHUT DOWN RELAY FOR ALL AIR SUPPLY UNITS. DETECTORS TO BE INSTALLED BY MECH. CONTR. 7. ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL A WEATHER PROOF, GROUND FAULT INTERRUPTER TYPE RECEPTACLE, AT AN ACCESSIBLE LOCATION FOR SERVICING ON ROOFTOP HEATING AND AIR CONDITIONING EQUIPMENT. THIS RECEPTACLE SHALL BE LOCATED WITHIN 25 FEET AND AT THE SAME LEVEL OF THIS EQUIPMENT. GROUND UP o GROUND DOWN D) RECEPTACLE MOUNTED 0 37" OR LOWER RECEPTACLE MOUNTED ® 38" OR HIGHER RECEPTACLE GROUND ORIENTATION. DETAIL KEYED NOTES: x ) 1. STORE FRONT SIGN CONTROLLED BY TIME SWITCH LOCATED NEAR DESK IN BACK AREA. E.C. TO VERIFY LOCATION OF SIGN JUNCTION BOX AND QUANTITY OF CIRCUITS NEEDED WITH SIGN CONTRACTOR AND ARCHITECT. 2. SEE ELECTRICAL/DATA PHONE BANK DETAIL, SHEET COM1. 3. RECESSED MOUNTED RECEPTACLE FOR CLOCK. VERIFY EXACT LOCATION WITH FIELD REPRESENTATIVE BEFORE INSTALLING. 4. FLUSH MOUNTED 120V RECEPTACLE MOUNTED AT 6" ABOVE WINDOW FOR NEON SIGNS. SEE KEYNOTE 1 SHEET Al FOR HEADER /SOFFIT NOTES 5. RECEPTACLE FOR COMPONENT CABINET. SEE "NETWORK CABINET DETAIL ELEVATION ", SHEET COM1 FOR MOUNTING HEIGHT REQUIREMENTS. 6. FLUSH MOUNTED RECEPTACLE AT +128" AFF FOR NEON SIGN. GENERAL ELECTRICAL NOTES: FILE COPY Penult No. _0 Plan review app. )vat is subject to errors and omilonl. Approval of construction documents does not the violetio dopted e o r ordi of appro 1. RUN WIRING TO P.O.S. AND PREPERA11ON TABLES THRU WIRING CHASE PROVIDED IN THE CABINETS. CONCEAL CONDUIT RISER TO CEILING BEHIND WALL ARRANGE CONDUIT SO DATA WIRING CAN BE DAISY CHAINED ONE OUTLET TO THE NEXT. 2. ALL 120V RECEPTACLES IN PREP AREA ARE TO BE GFI PROTECED. ANY OTHER RECEPTACLES IDENTIFIED AS Gil PROTECTED SHALL BE GFI DEVICES, OR CONNECTED TO GA CIRCUIT BREAKER OR CONNECTED DOWNSTREAM OF AND PROTECTED BY A GFI DEVICE. 3. TELEPHONE BOARD /PUNCHDOWN BLOCK IS TO BE MOUNTED ABOVE REFRIGERATOR IN BACK PREP AREA, NOT EXPOSED TO PUBLIC. 4. E.C. SHALL COORDINATE REQUIRED CONDUIT AND CONDUIT INSTALLATION LOCATIONS WITH COMMUNICAT1ONS /DATA CONTRACTOR. 5. NO SURFACE MOUNTED CONDUIT ALLOWED ON WALL SURFACES IN EXPOSED AREAS. ALL CONDUIT SERVING DEVICES IN EXTERIOR WALLS MUST BE CONCEALED WITHIN THE WAILS. . ANY EXISTING MC CABLE WHICH WILL BE IN EXPOSED AREAS TO BE REPLACED WITH RIGID CONDUIT. 9 y + SEPARATE PERMIT REQUIRED FOR: bil Mechanical Electrical Plumbing Gas Piping s P ping City of Tukwila BUILDING DIVISION WOMEN 104 DINING C PANEL A MEN itt4irY //.I. (,,.1479k7'' .f ./ FREEZER A -1. 13'x6' COOLER & FREEZER 9,41 G STORAGE REVIEWED .FOH OMPLIANCE WITH NFPA 70 - NEC JUL 282011 0 0. City of- UILDING ila VISION #8 WG1 Al 1 A -18 +12" KITCHEN/PREP Revisions ISSUE FOR JJ REVIEW 006/30/11 ISSUE FOR PERMIT/ . LL REVIEW 07/15/11 DINING A ri00 DINING B 4 IA -23h WP 0 A25,27 A 11MESNATCH POWER PLAN SCALE: 1 /4" = 1' -0" CITY OF TUK LA JUL 19 2011 PERMIT CENTER REVISIONS No changes shall be made to. the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submitt2l and may include additional plan review f�ca City Of 1likwile BUILDING DIVISION Emessmeassmassei Abossein Engineering, L.L.C. MECHANICAL - ELECTRIC 4L CIVIL . LEED FIRE PROTECTION 2100 112TH AVE. NE BELLEVUE, WA 98004 PH: (425) 462.9441 FAX: (425) 462 -9451 E -Mail: cservice @abossein,com www.abossein.com ARCHITECT HEREBY CERTIFY IUAT THESE PLANS HAVE SEEN ME- UNDER MY SUPERVISION AND THAT TO THE BEST IF NY IIWVLEDGE, 71E SALE COMPLY VITH ALL RILES, REGULATIONS AND ORDINANCES OF TWCVILA. Vq RELATING TO STRUCTURES AND BUILDINGS. Drawn By Checked By Scale Date 1 /4 " =1' -0" 06/30/2011 Job No. 1 1 2100 Sheet No. E 1 (0F4). LIGHTING FIXTURE SCHEDULE NOTES: 1. ELECTRICAL CONTRACTOR SHALL SUBMIT EIGHT (8) SETS OF CATALOG CUTS FOR ARCHITECT /ENGINEER REVIEW, PRIOR TO ORDERING FIXTURES. REVIEW, PRIOR TO ORDERING FIXTURES. . 2. ALL ACRYLIC LENS SHALL BE 100% VIRGIN ACRYLIC. 3. ALL FLUORESCENT LAMPS SHALL BE ENERGY SAVING TRIM UNE T8 WARM WHITE F32T8 /SP35 /RS 4. ALL BALLASTS SHALL BE RAPID START ELECTRONIC ENERGY SAVING TYPE. . 5. ALL EXIT SIGNS AND EMERGENCY UGHT FIXTURES ARE TO BE STRICT ACCORDANCE WITH THE LOCAL FIRE PREVENTION CODE AUTHORITY. ANY MODIFICATIONS TO UPGRADE SYSTEM SHALL BE INCLUDED IN THE BASE BID. ALL EXIT SIGNS ARE TO BE INSTALLED IN A VISIBLE LOCATION. ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL WHERE NECESSARY TO DROP A SIGN BELOW AN OBSTRUCTION. . 6. ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL THE NECESSARY CUPS, SCREWS, RIVETS, ETC., TO SECURELY FASTEN RECESSED LAY —IN LIGHTING FIXTURES TO CEIUNG FRAMING GRID WORK. 7. ALL UGHTING FIXTURES SHALL BEAR THE APPROPRIATE UL LABEL FOR THE APPUCATION AND UNION LABEL WHERE REQUIRED. 8. ALL UGHTING FIXTURES SHALL BE SHATTER PROOF OR COMPLETLEY SHIELDED /COVERED. NO SUBSTITUTIONS ON ANY FIXTURES. (304: UNISTRUT TO BE MOUNTED PARALLEL TO TRACK INSTALLATION THREADED ROD TRACK MOUNTED TO UNISTRUT 1 72" AFF 10' -6" AFF } 60" AFF IJ TYP DETAIL 0 HIGH TABLE (0 LOW TABLES, PENDANT HEIGHT IS 60" AFF) TYPICAL LIGHTING PLACEN ENT DETAIL SCALE: NONE REFLECTED CEILING NOTES 1. REFER TO MECHANICAL FOR EXACT NUMBER, TYPE AND LOCATION OF SUPPLY, RETURN AND EXHAUST FIXTURES. 2. REFER TO ELECTRICAL FOR EXACT NUMBER, TYPE AND LOCATION OF OUTLETS. 3. G.C. WILL COORDINATE THE WORK OF ALL TRADES INVOLVED IN THE CEILING WORK TO INSURE CLEARANCES FOR FIXTURES, DUCTS, PIPING, CEILING SUSPENSION SYSTEMS, ETC, NECESSARY TO MAINTAIN THE FINISHED CEILING HEIGHTS INDICATED ON ARCHITECTURAL DRAWINGS. 4. PERIMETER CEILING ANGLE. WHERE OCCURS, SHALL BE INSTALLED TIGHT TO PARTITION SURFACES, FREE FROM CURVES, BREAKS OR OTHER IRREGULARITIES BY G.C. 5. PROVIDE CEILING ACCESS AS REQUIRED FOR EQUIPMENT AND SYSTEM MAINTENANCE VERIFY MANUFACTURER RECOMMENDATIONS. 6. ALL SWITCHES AND DIMMERS SHALL BE LOCATED 48" ABOVE FINISHED FLOOR, TO CENTER OF SWITCHES AND 6" FROM DOOR FRAME U.O.N. MULTIPLE SWITCHES AT ONE LOCATION SHALL BE GAINED TOGETHER AND FINISHED WITH ONE COVER PLATE. 7. ALL SPECIFIC INFORMATION CONCERNING INSTALLATION OF VARIOUS ABOVE . CEILING ELEMENTS ARE TO BE FOUND IN THE HVAC, PLUMBING, FIRE PROTECTION, ELECTRICAL AND LIGHTING DRAWINGS. 8. CONTRACTOR TO NOTIFY ARCHITECT OF ANY CONFLICT OF LIGHT FIXTURE LOCATIONS WITH MAIN RUNNERS, DUCTS, ETC., PRIOR TO INSTALLATION. 9. FURNISH AND INSTALL UNDERWRITERS LABORATORY, INC (UL) LABELED DEVICES THROUGHOUT. 10. G.C. TO INSURE THAT EXIT SIGNS & EMERGENCY LIGHTING TO MEET ADA /IBC REQUIREMENTS. 11. ANY EXPOSED CONDUIT IN DINING ROOM MUST BE METAL CONDUIT AND RUN TIGHT TO THE DECK. ONLY EXCEPTION IS MC CABLE MAY BE USED WHEN CONNECTING TRACK UGHTING TO THE JUNCTION BOX. NO MC CABLE CAN BE RUN LONGER THE 12" WHEN RUNNING HORIZONTALLY ON THE DECK TO THE JUNCTION BOX. 12. MC CABLE USED TO POWER THE TRACK UGHTING IS TO BE INSTALLED TIGHT TO THE THREADED RODS TO THE UVE END OF THE TRACK. 13. NO SURFACE MOUNTED CONDUIT ALLOWED ON WALL SURFACES IN EXPOSED AREAS. ALL CONDUIT SERVING DEVICES IN EXTERIOR WALLS MUST BE CONCEALED WITHIN THE WALLS. 14. ANY EXISTING MC CABLE WHICH WILL BE IN EXPOSED AREAS TO BE REPLACED WITH RIGID CONDUIT. 5/8" GYPSUM BOARD NUT WOOD BLOCKING /JOIST BLOCKING TO BE FIRE RATED. (2) NUTS FLAT WASHER SPRING NUT 1 -1/2" DEEP P100 UNISTRUT • 101 151 SAMMY 3/8" ALL— THREADED ROD SPACED HORIZONTALLY AT 5' -0" 0.C. MAX. GH11NG TRACK UNI —STRUT DETAIL # SCALE: NONE NOTE: UNI —STRUT IS TO STOP SHORT EXACTLY 6" FROM END OF TRACK. ALL JOINTS IN UNI -STRUT ARE TO BE SECURELY FASTENED USING HEAVY DUTY JOINING PLATES. BOTTOM OF UNI —STRUT TO BE AT 10' -6 ". SPRING NUT FLAT WASHER (2) NUTS (2) NUTS FLAT WASHER STRUCTURAL MEMBER SPRING NUT 1 -1/2" DEEP P100 UNISTRUT UNI 1 -1/2" DEEP P1000 UNISTRUT SP AT TOP OF BAR JOIST. NOT TO BE SECURED TO ROOF DECKING. ONLY TO BE SECURED TO UNISTRUT /STRUCTURAL MEMBERS. 3/8" ALL— THREADED ROD SPACED HORIZONTALLY AT 5' -0" 0.C. MAX: UGHTING TRACK STRUT DETAIL #2 SCALE: NONE REVIEWED 1-01 COMPLIANCE CNECTH JUL 23 2011 City ofTptV1SI0N � BUILDINg A -17c VIA UGHTOUER 720W CURRENT OMEN 104 DINING C 100 5 u E1 A -17 1 R A -17 DINING A 100 E E EM A -1 4) 11 11 u 11 11 4C qC A -17b (MINIz RELAY 'B') VIA UGHTOUERLD120BK 120W CURRENT UMITER A -17a (MINIz RELAY 'A') VIA UGHTOUER #PLD120BK 120W CURRENT UMITER 1!i 0 ml FS C *21m m I i FSIC Ir -• n' MIT FC A -:t1 N S 19d FREEZER 6'x6` REFRIG. 6'x6' zl IN ACCESSIBLE CEIUNG (-1 ASE —19 NL A -19 d- MEN 105 COOLER & FREEZER <..a.h. w~.d.e..h...k......�.. AS A -19d Af - 9d 9d OG A -19 A -419 ASE A -19 NL 0 .__.. A 19 G OFG A19d TO MINIz PHO OCELL O CF A -13e EX • IN d 9d STORAGE 102 KITCHEN / PREP 101 !J. SOFF,l` PAINT P'F PAINT ET-5 DINING B LIGHTING PLAN PROVIDE LEVITON MINIZ DAYLIGHT MANAGEMENT SYSTEM WITH (2) ZONES /RELAYS MMIZB00 -102, COMPLETE WITH INDOOR PHOTOCELL #PCIND AND LOW VOLTAGE SWITCH #LV240 FOR OVERRIDE. SCENARIO ALLOWS FOR (3) LEVELS OF AUTOMATIC DAYLIGHT ZONE CONTROL ALL LAMPS ON (ZONES 'A' & 'B' BOTH ON) HALF OF LAMPS OFF (ZONE 'A' ON, ZONE 'B' OFF) ALL LAMPS OFF (ZONES 'A' & 'B' BOTH OFF) 100 RECEIVEP CITY OF TUKWILA JUL 19 2011 PERMIT CENTER Abossein Engineering, L.L.C. MECHANICAL - ELECTRICAL CIVIL - LEED FIRE PROTECTION 2100 112TH AVE. NE BELLEVUE, WA 98004 PH: (425) 462.9441 FAX: (425) 462-9451 E -Mail: cselvice @abossein.com vwwv.abossein.com ESEMENIEMIEEDEDIDIEDIE 1/2,0 M N Qo ti tlk 0 Te4 04 o. Bin WA Dil Fa '4 BM ji ifiv L'1 0 O (n W CO zwCo = C. O O �4-- 00 —00D Revisions LAISSUE FOR JJ REVIEW 06/30/11 OISSUE FOR PERMIT/ LL REVIEW 07/15/11 „J D < —1 I..IJ 0 _ U 0 () z W O D —J X LL ARCHITECT I HEREBY CERTIFY TINT THESE PLANS HAVE BEEN PRE- PARED UNDER HY SUPERVISION AND THAT TU TIE BEST IF NY MUM TIE SNE CORY WITH ALL RIN.ES, REGULATIONS AND ORDINANCES OF TUKVILA. VA RELATING TO STRUCTURES AND BUILDINGS. Drawn By Checked By. Scale 1 /4 " =1' -0" Date 06/30/2011 Job No. 11 2100 Sheet No. E2 (0F4) LIGHTING FIXTURE SCHEDULE SYMBOL DESCRIPTION MOUNTING AS UGHTOUER XT2GVA24012003 3 -25 2' X 4' LAMP: (2) 32W — F32T8 /CW (57 WATT) RECESSED CEILING GRID ASE UGHTOUER XT2GVA24012003 —EM 2 -32 2' X 4' LAMP: (2) 32W — F32T8 /CW (57 WATT) RECESSED CEIUNG • GRID W/E BALLAST EMERGENCY LIGHT . C T T — TRACK UGHTOUER— LYTESPAN 6000 MATTE BLACK C — BASIC MINI UNIVERSAL UGHTOUER #9021 BK LAMP: (1) PAR 30 CFL 15W ( UTETRONICS L -1372) D — UGHTOUER LYTEFLOOD COMPACT FLUORESCENT #8276EAL (2) 18W (22112) TWIN TUBE FLUORESCENT (36 WATT) E — UGHTOUER FSP501419 —MINI PENDANT WITH CORD, ATTACHMENT FITTING & RED GLASS. LAMP: (1) A19 CFL 5W (UTETRONICS MB- 500DP) T —TRACK MOUNTED AT 10' -6" A.F.F. (TYPICAL) C - TRACK MOUNT D = TRACK MOUNT E — TRACK PENDANT 72" A.F.F. OVER HIGH TABLES AND 60" A.F.F. OVER LOW TABLES AND BOOTHS. O . 1 E D F2 1....3 F2 — GOOSENECK ARM AND FIXTURE— McFADDEN UGHTING • #4417—B2- 22.5- 3/4 —AB0 LAMP: (1) 32W CFL 32 WATTS MENU BOARD GOOSENECK - WALL MOUNTED 11' -0" A.F.F. X ® UGHTOUER #LLNURW — LED EXIT WITH EMERGENCY BATTERY BACK UP 3.9 WATTS SEE PLAN — MOUNT ON WALL OR CEIUNG. EX UGHTOUER #LC14NH71RW — LED EXIT WITH EMERGENCY UGHTING HEADS BATTERY BACKUP 14.1 WATTS SEE PLAN — MOUNT ON WALL OR CEILING. . me ' A ''' EM LGHTOUER #E118NT6W — EMERGENCY UGHTING 2 HEAD UNIT W/ BATTERY BACKUP 9.2 WATTS SEE PLAN — MOUNT ON WALL OR CEIUNG. FS l FS — BATH RM LT., RAB LIGHTING VXLED13DG LAMP: LED 14 WATTS • . SEE PLAN — MOUNT ON WALL AT . +84" A.F.F. G 0 UGHTOUER #1101 LED UGHTOUER #1126 REFLECTOR TRIM LAMP: LED 15 WATTS SEE PLAN —. MOUNT IN SOFFIT CF /\ HUNTER FAN COMPANY PARAMOUNT #3856 MOUNT AT 108" A.F.F. E.C. SHALL FIELD VERIFY THE LENGTH OF DOWNROD FOR CEIUNG FAN. DOWNROD SHALL EXTEND FROM CEIUNG FAN TO STRUCTURE ABOVE. DOWNROD SHALL BE FLAT BLACK UGHTING FIXTURE SUPPUER: KEC CONTACT: DAN PROCTOR 301 E. MERCURY DRIVE SUITE #1 TEL (888)356 -1640 CHAMPAIGN, IL 61822 FAX: (217)356 -1661. EMAIL danproctorekecdesign.net NO SUBSTITUTIONS ON ANY FIXTURES. (304: UNISTRUT TO BE MOUNTED PARALLEL TO TRACK INSTALLATION THREADED ROD TRACK MOUNTED TO UNISTRUT 1 72" AFF 10' -6" AFF } 60" AFF IJ TYP DETAIL 0 HIGH TABLE (0 LOW TABLES, PENDANT HEIGHT IS 60" AFF) TYPICAL LIGHTING PLACEN ENT DETAIL SCALE: NONE REFLECTED CEILING NOTES 1. REFER TO MECHANICAL FOR EXACT NUMBER, TYPE AND LOCATION OF SUPPLY, RETURN AND EXHAUST FIXTURES. 2. REFER TO ELECTRICAL FOR EXACT NUMBER, TYPE AND LOCATION OF OUTLETS. 3. G.C. WILL COORDINATE THE WORK OF ALL TRADES INVOLVED IN THE CEILING WORK TO INSURE CLEARANCES FOR FIXTURES, DUCTS, PIPING, CEILING SUSPENSION SYSTEMS, ETC, NECESSARY TO MAINTAIN THE FINISHED CEILING HEIGHTS INDICATED ON ARCHITECTURAL DRAWINGS. 4. PERIMETER CEILING ANGLE. WHERE OCCURS, SHALL BE INSTALLED TIGHT TO PARTITION SURFACES, FREE FROM CURVES, BREAKS OR OTHER IRREGULARITIES BY G.C. 5. PROVIDE CEILING ACCESS AS REQUIRED FOR EQUIPMENT AND SYSTEM MAINTENANCE VERIFY MANUFACTURER RECOMMENDATIONS. 6. ALL SWITCHES AND DIMMERS SHALL BE LOCATED 48" ABOVE FINISHED FLOOR, TO CENTER OF SWITCHES AND 6" FROM DOOR FRAME U.O.N. MULTIPLE SWITCHES AT ONE LOCATION SHALL BE GAINED TOGETHER AND FINISHED WITH ONE COVER PLATE. 7. ALL SPECIFIC INFORMATION CONCERNING INSTALLATION OF VARIOUS ABOVE . CEILING ELEMENTS ARE TO BE FOUND IN THE HVAC, PLUMBING, FIRE PROTECTION, ELECTRICAL AND LIGHTING DRAWINGS. 8. CONTRACTOR TO NOTIFY ARCHITECT OF ANY CONFLICT OF LIGHT FIXTURE LOCATIONS WITH MAIN RUNNERS, DUCTS, ETC., PRIOR TO INSTALLATION. 9. FURNISH AND INSTALL UNDERWRITERS LABORATORY, INC (UL) LABELED DEVICES THROUGHOUT. 10. G.C. TO INSURE THAT EXIT SIGNS & EMERGENCY LIGHTING TO MEET ADA /IBC REQUIREMENTS. 11. ANY EXPOSED CONDUIT IN DINING ROOM MUST BE METAL CONDUIT AND RUN TIGHT TO THE DECK. ONLY EXCEPTION IS MC CABLE MAY BE USED WHEN CONNECTING TRACK UGHTING TO THE JUNCTION BOX. NO MC CABLE CAN BE RUN LONGER THE 12" WHEN RUNNING HORIZONTALLY ON THE DECK TO THE JUNCTION BOX. 12. MC CABLE USED TO POWER THE TRACK UGHTING IS TO BE INSTALLED TIGHT TO THE THREADED RODS TO THE UVE END OF THE TRACK. 13. NO SURFACE MOUNTED CONDUIT ALLOWED ON WALL SURFACES IN EXPOSED AREAS. ALL CONDUIT SERVING DEVICES IN EXTERIOR WALLS MUST BE CONCEALED WITHIN THE WALLS. 14. ANY EXISTING MC CABLE WHICH WILL BE IN EXPOSED AREAS TO BE REPLACED WITH RIGID CONDUIT. 5/8" GYPSUM BOARD NUT WOOD BLOCKING /JOIST BLOCKING TO BE FIRE RATED. (2) NUTS FLAT WASHER SPRING NUT 1 -1/2" DEEP P100 UNISTRUT • 101 151 SAMMY 3/8" ALL— THREADED ROD SPACED HORIZONTALLY AT 5' -0" 0.C. MAX. GH11NG TRACK UNI —STRUT DETAIL # SCALE: NONE NOTE: UNI —STRUT IS TO STOP SHORT EXACTLY 6" FROM END OF TRACK. ALL JOINTS IN UNI -STRUT ARE TO BE SECURELY FASTENED USING HEAVY DUTY JOINING PLATES. BOTTOM OF UNI —STRUT TO BE AT 10' -6 ". SPRING NUT FLAT WASHER (2) NUTS (2) NUTS FLAT WASHER STRUCTURAL MEMBER SPRING NUT 1 -1/2" DEEP P100 UNISTRUT UNI 1 -1/2" DEEP P1000 UNISTRUT SP AT TOP OF BAR JOIST. NOT TO BE SECURED TO ROOF DECKING. ONLY TO BE SECURED TO UNISTRUT /STRUCTURAL MEMBERS. 3/8" ALL— THREADED ROD SPACED HORIZONTALLY AT 5' -0" 0.C. MAX: UGHTING TRACK STRUT DETAIL #2 SCALE: NONE REVIEWED 1-01 COMPLIANCE CNECTH JUL 23 2011 City ofTptV1SI0N � BUILDINg A -17c VIA UGHTOUER 720W CURRENT OMEN 104 DINING C 100 5 u E1 A -17 1 R A -17 DINING A 100 E E EM A -1 4) 11 11 u 11 11 4C qC A -17b (MINIz RELAY 'B') VIA UGHTOUERLD120BK 120W CURRENT UMITER A -17a (MINIz RELAY 'A') VIA UGHTOUER #PLD120BK 120W CURRENT UMITER 1!i 0 ml FS C *21m m I i FSIC Ir -• n' MIT FC A -:t1 N S 19d FREEZER 6'x6` REFRIG. 6'x6' zl IN ACCESSIBLE CEIUNG (-1 ASE —19 NL A -19 d- MEN 105 COOLER & FREEZER <..a.h. w~.d.e..h...k......�.. AS A -19d Af - 9d 9d OG A -19 A -419 ASE A -19 NL 0 .__.. A 19 G OFG A19d TO MINIz PHO OCELL O CF A -13e EX • IN d 9d STORAGE 102 KITCHEN / PREP 101 !J. SOFF,l` PAINT P'F PAINT ET-5 DINING B LIGHTING PLAN PROVIDE LEVITON MINIZ DAYLIGHT MANAGEMENT SYSTEM WITH (2) ZONES /RELAYS MMIZB00 -102, COMPLETE WITH INDOOR PHOTOCELL #PCIND AND LOW VOLTAGE SWITCH #LV240 FOR OVERRIDE. SCENARIO ALLOWS FOR (3) LEVELS OF AUTOMATIC DAYLIGHT ZONE CONTROL ALL LAMPS ON (ZONES 'A' & 'B' BOTH ON) HALF OF LAMPS OFF (ZONE 'A' ON, ZONE 'B' OFF) ALL LAMPS OFF (ZONES 'A' & 'B' BOTH OFF) 100 RECEIVEP CITY OF TUKWILA JUL 19 2011 PERMIT CENTER Abossein Engineering, L.L.C. MECHANICAL - ELECTRICAL CIVIL - LEED FIRE PROTECTION 2100 112TH AVE. NE BELLEVUE, WA 98004 PH: (425) 462.9441 FAX: (425) 462-9451 E -Mail: cselvice @abossein.com vwwv.abossein.com ESEMENIEMIEEDEDIDIEDIE 1/2,0 M N Qo ti tlk 0 Te4 04 o. Bin WA Dil Fa '4 BM ji ifiv L'1 0 O (n W CO zwCo = C. O O �4-- 00 —00D Revisions LAISSUE FOR JJ REVIEW 06/30/11 OISSUE FOR PERMIT/ LL REVIEW 07/15/11 „J D < —1 I..IJ 0 _ U 0 () z W O D —J X LL ARCHITECT I HEREBY CERTIFY TINT THESE PLANS HAVE BEEN PRE- PARED UNDER HY SUPERVISION AND THAT TU TIE BEST IF NY MUM TIE SNE CORY WITH ALL RIN.ES, REGULATIONS AND ORDINANCES OF TUKVILA. VA RELATING TO STRUCTURES AND BUILDINGS. Drawn By Checked By. Scale 1 /4 " =1' -0" Date 06/30/2011 Job No. 11 2100 Sheet No. E2 (0F4) Interior Lighting Summary LTG -INT 2009 Washington State Energy Code Compliance Forms for Nonresidential and M ultifamily Residential Revised December 2010 Project Info Project Address JD1 M Y JOHNS Date 6/29/2011 16 864 S O U T H C E N T E R .PKWY For Building Department Use TUKW ]LA W A Applicant Name: Applicant Address: Applicant Phone: Project Description n ecessary to check a permit ap pli cation for compliance with th e lighting, motor, and transformer requirements In Nonresidential Energy Code. ❑ New Building ❑ Addition v Alteration 4, Plans Included Indicate controls (Sections 1513) including commissioning requirements on plans. Compliance Option Location on Flans • Prescriptive 0 Lighting Power Allowance • Systems Analysis lj Clear (See Qualification Checklist ( over). Indicate Prescriptive & LPA spaces cleariyon plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting and space use not changed • Less than 60% of th e fixtures new, installed wattage not increased, & space use not changed. Maximum Allowed Lighting Wattage Location (floor plan /room #) Occupancy Description Allow ed Watts per ft2 ** Gross Interior Area in ft2 Allow ed x Area Compliance Forms for Nonresidential and M ultifamily Residential Revised December 20'0 RESTAURANT 1.20 685.0 822 n ecessary to check a permit ap pli cation for compliance with th e lighting, motor, and transformer requirements In Nonresidential Energy Code. RESTAURANT- 17'CEII,NG HEIGHT 1.40 730 1022 Location on Flans TRACK -720W CURRENT L]M IPER 1 720.0 720 ** From Table 15 -1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts 1844 Proposed Lighting Wattage Location (floor plan/room #) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Compliance Forms for Nonresidential and M ultifamily Residential Revised December 20'0 FS - BATHROOM FIXTURE -LED 6 14.0 84 n ecessary to check a permit ap pli cation for compliance with th e lighting, motor, and transformer requirements In Nonresidential Energy Code. AS/ASE - RECESSED LENSED TROFFER (2) 32W T8 10 57.0 570 Location on Flans TRACK -720W CURRENT L]M IPER 1 720.0 720 1513.1 TRACK -120W CURRENT L47 ITER 2 120.0 240 F2 -S3;N GOOSENECK - (1) 32W CFL . 3 32.0 96 E2 0 - RECESSED CAN -LED 8 15.0 120 Daylight zone control Schedule w ith type and features, indicate locations E2 Yes vertical glazing Indicate vertical glazing on plans E2 N.A. overhead glazing Indicate overhead glazing on plans N.A. 1513.4 Display /exhib /special Indicate separate controls Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts 1830 Lighting, 2009 Washington Motor, and Transformer Permit Plans Checklist LTG -CHK State Energy Code Compliance Forms for Nonresidential and M ultifamily Residential Revised December 20'0 Project Address J$a M Y do H N S Date 6/29/2011 The following information is the 2009 Washington State n ecessary to check a permit ap pli cation for compliance with th e lighting, motor, and transformer requirements In Nonresidential Energy Code. Applicability (yes, no, n.a.) Code Section Component Information Required Location on Flans Building Department Notes LIGHTING CONTROLS (Section 1513) Yes 1513.1 Local control/access Schedule with type, indicate locations E2 } 1513.2 Area controls Maximum limit per sw itch E2 Yes 1513.3 Daylight zone control Schedule w ith type and features, indicate locations E2 Yes vertical glazing Indicate vertical glazing on plans E2 N.A. overhead glazing Indicate overhead glazing on plans N.A. 1513.4 Display /exhib /special Indicate separate controls Yes 1513.5 Exterior shut -off Schedule with type and features, indicate location Yes (a) timer w /backup Indicate location E2 .1, E1 N.A. gl (b) photocell. Indicate location Yes 1513.6 Inter. auto shut -off Indicate location 1513.6.1 (a) occup. sensors Schedule with type and locations E2 1513.62 (b) auto. switches Schedule with type and features (back -up, override capability); Indicate size of zone on plans . E2.1 N.A. 1513.7 Hotel/motel controls Indicate location of room master controls Yes 1513.8 Commissioning Indicate requirements for lighting controls commissioning E2.1 EXIT SIGNS (Section 1514) Yes . 1514 Max. w atts Indicate w atts for each exit sign E2 LIGHTING POWER ALLOWANCE (Section 1530 -1532) Yes w 1531 Interior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, w atts per fixture E2.1 N.A. 'v 1532 Exterior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, w atts per fixture MOTORS (Section 1511) N.A. ED 1511 Bec motor efficiency MECH -MOT or Equipment Schedule w ith hp, rpm, efficiency TRANSFORMERS (Section 1540) N.A. 0 1540 Transformers Indicate size and efficiency REVIEWED FON COMPLIANCE WITH NFPA 70 - NEC JUL 232011 City of Tukwila BUILDING DIVISION 1513.8 COMMISSIONING REQUIREMENTS: FOR LIGHTING CONTROLS WHICH INCLUDE DAYUGHT OR OCCUPANT SENSING AUTOMATIC CONTROLS, AUTOMATIC SHUT —OFF CONTROLS, OCCUPANCY SENSORS, OR AUTOMATIC TIME SWITCHES, THE UGHTING CONTROLS SHALL BE TESTED TO ENSURE THAT CONTROL DEVICES, COMPONENTS, EQUIPMENT AND SYSTEMS ARE CALIBRATED, ADJUSTED AND OPERATE IN ACCORDANCE WITH APPROVED PLANS AND SPECIFICATIONS. SEQUENCES OF OPERATION SHALL BE FUNCTIONALLY TESTED TO ENSURE THEY OPERATE IN ACCORDANCE WITH APPROVED PLANS AND SPECIFICATIONS. SEE SECTION 1416 FOR COMPLETE REQUIREMENTS. LIGHTI G CO \TROL DIAGRAM ERI OR/EXTERI OR 120V CONSULT OWNER'S REPRESENTATIVE IN FIELD FOR TIME /OPERATION SCHEDULING. PROVIDE SEPERATE SURFACE MOUNT ENCLOSURES FOR CONTACTORS. SIZE PER NEC. TIMER POWER CIRCUIT #1 CIRCUIT #2 C NO NC —oho PROVIDE TIMED OVERRIDE SWITCH PER NREC 1513.6.2 TORK SS20 OR EQUAL SET TO 2HR OVERRIDE MAX. LOCATE AT • SWITCHBANK 20A1P A -13 0 20A1P A -17 0 0 20A1P A -19 . 0 0 20A1P 0 0 TORK ASTRONOMIC TIMESWITCH #EWZ201 OR EQUAL CIRCUIT #1 = INTERIOR LIGHTING CIRCUIT #2 = EXTERIOR LIGHTING 30A ELECTRICALLY HELD LIGHTING CONTACTOR (TYPICAL) 20A1P CEILING FANS A -25 OHO 20A1P TRACK LIGHTING A -27 OHO 20A1P KITCHEN LIGHTING OHO 20A1P SPARE 0 —O �o- 120V 30A ELECTRICALLY HELD LIGHTING CONTACTOR (TYPICAL) EXTERIOR SIGNAGE EXTERIOR SIGNAGE SPARE SPARE EL11 0 low RECEIVED CITY OF TUKWILA JUL 19 2011 PERMIT CENTER Essismasammena Abossein Engineering, L.L.C. MECHANICAL-ELECTRICAL CIVIL - LEED FIRE PROTECTION 2100 112TH AVE. NE BELLEVUE, WA 98004 PH: (425) 462 -9441 FAX: (425) 462.9451 E-Mail: cseMce @abossein.com www.abossein.com NEMENNINIMENSINENSWEEIEN h Atv O r r • 0 .0 ■" s •O O u' c 0000 . :e ' f...- mo• 4) w co ov- 0 4j wCD iris /rte J-. 3 0 n I) : P •� .0 _ ev Revisions 0 ISSUE FOR JJ REVIEW 06/30/11 ISSUE FOR PERMIT/ L3LL REVIEW 07/15/11 (f) LLJ 0 0 0 0 z 0 0 Izz� L.tJ < —1 Z —I LIJ Q 0 ARCHITECT U I HEREBY CERTIFY THAT 1)ESE PLANS HAVE TEEN PRE- PARED UNDER NY SWERVISMN AND THAT TO TIE BEST W NY IOOYLEDGE, TIE SANE CONPI.Y VITH ALL RUES, REGILATIO TOAND ORDINANCES OF T1 Ctd1LA. V4. RELATING TO STRUCTURES AND'BUILDINGS. Drawn By Checked By Scale 1/4"=1 ' -on Date 06/30/2011 1e1-2100 Sheet No. ALL CABLING AND TERMINATION TO BE COMPLETED BY COMM /DATA SUB — CONTRACTOR. COMM /DATA SUB — CONTRACTOR TO COORDINATE LOCATION AND SIZE OF NECESSARY CONDUITS FOR CABLING WITH ELECTRICAL CONTRACTOR. DSL PHONE UNE MOUNTED WITHIN CABINET AMOUNT OF HOMERUNS TO EQUAL THE AMOUNT OF DATA JACKS ON THE FLOOR PLANS. DUPLEX RECEPTACLE MOUNTED WITHIN CABINET DEDICATED DRIVERS DISPATCH (if applicable) EVERY COLD TABLE IF PRINTERIS.NDTNEXT.TOA (ASH REGISTER: THENANADBITIONAL PEGNTER MUST BE INSTALLEDAT THEAMKEUNE.. NETWORK COMPONENT CABINET — EQUIP. WITHIN CABINET INCLUDE — 24 —PORT PATCH PANEL. ROUTER /SWITCH, DSL MODEM, CALLER ID RECESSED DATA UNE - FROM ROUTER /SWITCH. TO COMPUTER DATA FLUSH MOUNTED JUNCTION BOX FOR RECESSING SPEAKER WIRE KVM/VGA PORT PORT AND CABLE SUPPLIED BY SIGNITURE SYSTEMS METRO DESK & SHELVES PROVIDED BY KEC KW/VGA PORT PORT AND CABLE SUPPLIED BY SIGNITURE SYSTEMS ALL PHONE UNES ABOVE CEIUNG FROM PUNCHDOWN BLOCK TO 6 PORT SURFACE MOUNT BOX PANEL — ONE EA. FOR UNES A.B,C,&D AND TWO UNES FOR FAX/DSL UNE .-----RECESSED 2' CONDUIT FOR VGA AND USB CABLES TO RUN BETWEEN VGA/USB PORTS — NO TURNS IN CONDUIT RECESSED.3 /4' DUIT STUBBED OUT AB VE DROP CEILING FOR SP ER WIRE' FREEZER t3'x6' ER & FREEZER RECESSED 2' COI DUIT FOR VGA AND USB CABLES TO RUN BETWEEN VGA/US8 PORTS — NO TURNS IN COI DUIT WOMEN MANPATORY.illClt;S REFRIG. 6' x 6' DRIVE-THRU (if applicable) 3 DATA, — 1 PHONE, & 2 QUAD RECEPTACLES SERIAL CABLE — FOR THE DATASYM CASH REGISTER STORAGE 502 NETWORK CABINET DETAIL ELEVATION SCALE: NONE DINING C X100 PHONE JACK FROM FAX UN 'iii ?"14 ABOVE DRIVER'S BOX Blackly lt'= Fa<IJne P(oneltk _> . fnr ligacy credit card terminal diaL• up backup) E>itra NRWorklackf5r fu ture:conideratIori nr credit 6rd terminal .0.1*.lack; =R145: 4010k 44: POWER DATA PHONES ..EVER WALLPLATEJACK: IS A.HOME RU.N: CATS TO RACKMQUNT`PATCH PANEL . FRONT ELEVATION OFFICE — NEAR CEILING RACKMOUNT PATCH PANEL ALL RACK EQUIPMENT . INSIDE . NETWORK:CABINET RACKMOUNT POWER DISTRIBUTION UNIT" CABLE LEGEND CATS UTP CABLE HIADEN IN WALL, CEILING OR FLOOR..::: CAT5'CABLE GoIa,SeiGarr. PHONE LINE RA KMOI.INT24 POR.T5;:WIT H, (I It E111t2 TINE EWf +1f, V' EA%%DSLLINE EAXIN9:l.INES OFFICE Apgve`Drop(elllig ■ :.KVM ;DEI ARCATIONPaNT- (:DMARCj ©2010 JIMMY JO'HN'S FRANCMI,SE,L LC AI L RIGHTS RE..S'ERVED: COMPONET BOX REQUIRED EQUIPMENT: COMPLETE COMPONENT BOX PROVIDED BY SIGNATURE SYSTEMS: NETWORK CABINET : MIDDLE ATLANTIC EWR817 OR. EWR1017 REQUIRED QUIPMENT WITHIN THE COMPONET CABINET: PATCH PANEL — PANDUIT CFAPPBL1 (QTY 1) POWER DISTRIBUTION UNIT — MIDDLE ATLANTIC PD- 915RV —R13 (QTY 1) 24 PORT NETWORK SWITCH — DELL POWER CONNECT 3524 (QTY 1) ROUTER WITH DIAL BACKUP — NETOPIA 4686XL WITH DIAL —UP (QTY 1) RACK SHELF — MIDDLE ATLANTIC UTR1 (QTY 2) CABLE STRAPS - MIDDLE ATLANTIC TW12 (QTY 1) PATCH CABLES —1' PATCH CABLES (QTY 10 * *) RACK SCREWS —10/32 RACK SCREWS (QTY 1 BOX) VGA & USB WALL PLATE (QTY 2) VGA DUEL PANEL -MOUNT F/F CABLE QTY 1 USB 2.0 DUAL PANEL -MOUNT CABLE QTY 1) 2.0 MINI COAX DH15MM (QTY 1) 1) VENDOR CONTACT: Signature Systems, Inc 11 Penns Trail Newtown, PA 18940. Sales: (877) 968 -6430 or sales®pdgpos.com Fax: (215) . 968 -6431 Dedicated JJ Tech Support: (877) 844 -5313 * CALLER ID BOX IS ONLY REQUIRED FOR STORES THAT ARE INSTALLING POS — PROVIDED BY SIGNATURE SYSTEMS. ** QTY IS NUMBER OF NETWORK RUNS PLUS 2 EXTRA ELECTRICAL /DATA PHONE BANK DETAIL SCALE: NONE KEYED NOTES:( X 1. MOUNT THE NETWORK ELECTRONIC COMPONENT CABINET TIGHT TO CEILING ABOVE SHELVES IN THE BACK PREP AREA. SEE NETWORK CABINET DETAIL AND GENERAL NOTES ON THIS SHEET FOR INFORMATION ON CABLING AND COMPONENTS WITHIN CABINET. SEE COMPONENT BOX EQUIPMENT UST ON COM -1 SHEET. 2. PROVIDE ONE (1) 3/4" CONDUITS STUBBED UP INTO ACCESSIBLE CEILING. VERIFY LOCATION IN FIELD FOR ALL VOICE AND DATA LOCATIONS. SEE ELECTRICAL/DATA PHONE BANK DETAIL, THIS SHEET. DATA LEGEND: D DATA OUTLET (X) = AMT. OF DATA JACKS (JACK = ORANGE) 1 PHONE JACK (JACK = BLACK) k 2 DATA JACKS (JACK = ORANGE) & 1 PHONE JACK (JACK = BLACK) ® 3 DATA JACKS (JACK = ORANGE) & 1 PHONE JACK (JACK = BLACK) ty DATASY I POS — BELDEN STRANDED 4 —WIRE, UNTERMINATED VGA/USB PORT — 1 VGA JACK AND 1 USB JACK GENERAL NOTE: PHONE COMPANY TO PROVIDE 4 PHONE LINES ON ROLLOVER SERVICE & ONE (1) DSL/FAX UNE. GENERAL ELECTRICAL NOTES: 1. RUN WIRING TO P.O.S. AND PREPARATION TABLES THRU WIRING CHASE PROVIDED IN' THE CABINETS. CONCEAL CONDUIT RISER TO CEILING BEHIND WALL ARRANGE CONDUIT SO DATA WIRING CAN BE HOME RUNS TO THE PATCH PANEL WITHIN THE NETWORK CABINET ABOVE THE DESK. 2. SEE ELECTRICAL/DATA PHONE BANK DETAIL ON THIS SHEET FOR INSTALLATION OF PHONE/DATA EQUIPMENT 3. ALL PHONE CAT -5e HOME RUN TO PUNCHDOWN BLOCK. 4. ALL DATA CABLES TO TERMINATE ON RJ45 CATEGORY 5e JACKS AND WIRE TO EIA /11A 568 —B.1 STANDARDS. 5. ALL DATA CABLES TO HOMERUN AND TERMINATE ON 24 —PORT RACKMOUNT PATCH PANEL TO BE MOUNTED IN THE NETWORK CABINET. 6. ALL CABLES TO BE CONTINUITY TESTED FOR POLARITY AND CORRECT PIN CONFIGURATION AND MACHINE LABELED. 7. DAISY —CHAIN BELDEN STRANDED 4 —WIRE (PROVIDED BY CASH REGISTER VENDOR) FROM EACH CASH REGISTER TO NEXT, THEN BACK TO MANAGER'S DESK. 8. ALL NETWORK CABLING IN THE STORE MUST BE CATEGORY 5e CERTIFIED. YOU MUST OBTAIN A CERTIFICATION REPORT FROM YOUR COMMUNICATIONS /LOW VOLTAGE SUBCONTRACTOR. 9. STEREO SYTEM WRING — SEE NETWORK CABINET DETAIL FOR JUNCTION BOX LOCATION AND RECESSED CONDUIT INSTRUCTIONS FOR STEREO SPEAKER WIRE. +12 "A.F.F. (2) I KITCHEN 1 PREP 101 +12 "A.F.F. (4) +80 "A..F. ()I D = VOICE UNE 4 C = VOICE UNE 3 B = VOICE UNE2 Revisions ISSUE FOR JJ REVIEW 0 06/30/11 A ISSUE FOR PERMIT/ / \LL REVIEW 07/15/11 DINING A 100 COMM/DATA PLAN SCALE: 1 /4" = 1' -0" Abossein Engineering, L.L.C. ARCHITECT I IEREBY CERTIFY THAT THESE PLANS HAVE BEEN PRE- PARED TRITER NY SUPERVISION NO THAT TO THE BEST OF NY 10n4LEDli, THE SNE COMPLY VITN ALL RILES, REGULATDDNS AND ORDINANCES OF TLDi41ILA. VA; RELATING TO STRUCTURES AND BUILDINGS. MECHANICAL - ELECTRICAL CIVIL - LEED. FIRE PROTECTION 2100 112TH AVE. NE BELLEVUE, WA 98004 PH: (425) 462-9441 FAX: (425) 462-9451 E -Mail: cservice @abossein.com www.abossein.com Drawn By Checked By Scale 1 /4 " =1' -0" Date 06/30/2011 Sheet No. c 0 1 I (OF 4) MECHANICAL, ELECTRICAL, PLUMBING GENERAL NOTES 1. THE M /E /P CONTRACTORS SHALL REVIEW ENTIRE SET OF CONTRACT DOCUMENTS: INCLUDING BUT NOT NECESSARILY LIMITED TO ALL ARCHITECTURAL, ALL STRUCTURAL, ALL MECHANICAL, ALL ELECTRICAL, ALL PLUMBING, AND ENTIRE PROJECT MANUAL. ELECTRICAL CONTRACTOR SHALL ACKNOWLEDGE AND INCLUDE IN THE SCOPE OF WORK (CONTRACT) ALL CONDITIONS PERTINENT TO THE COMPLETION OF THE ELECTRICAL WORK. ELECTRICAL CONTRACTOR SHALL FULLY COORDINATE ELECTRICAL WORK WITH THE INSTALLATION OF WORK BY ALL OTHER TRADES AND MAKE NECESSARY FIELD ADJUSTMENTS AS REQUIRED TO ACCOMMODATE THE ELECTRICAL INSTALLATION. ALL OF THE ABOVE SHALL BE INCLUDED IN THE SCOPE OF WORK AT NO ADDITIONAL COST TO THE OWNER. 2. THE M /E /P CONTRACTORS SHALL CAREFULLY EXAMINE THE DRAWINGS AND SPECIFICATIONS, VISIT THE SITE OF THE WORK, AND FULLY INFORM HIMSELF AS TO ALL CONDITIONS AND MATTERS THAT CAN, IN ANY WAY, AFFECT THE WORK OR THE COST THEREOF, SHOULD THIS CONTRACTOR FIND DISCREPANCIES IN, OR OMISSIONS FROM, THE DRAWINGS, SPECIFICATIONS OR OTHER DOCUMENTS OR BE IN DOUBT AS TO THEIR MEANING, NOTIFY THE ARCHITECT /ENGINEER AT ONCE, IN WRITING, OF ANY DISCREPANCIES BETWEEN EXISTING CONDITIONS AND NEW WORK, OR BETWEEN ELECTRICAL WORK AND. THE WORK OF OTHER TRADES PRIOR AND OBTAIN CLARIFICATION PRIOR TO SUBMITTING ANY BID. LACK OF SUCH NOTIFICATION SHALL BE CONSTRUED TO INDICATE NO DISCREPANCIES OR CONFLICTING EXIST. ADDITIONAL COMPENSATION WILL NOT BE GRANTED AFTER AWARD OF CONTRACT FOR ANY WORK REQUIRED TO COMPLY WITH THESE REQUIREMENTS. 3. THE DRAWINGS INDICATE THE DIAGRAMMATIC. INTENT, GENERAL CHARACTER, REQUIREMENTS AND LOCATION OF THE WORK SHOWN AND INCLUDED. THE WORK INDICATED BUT HAVING MINOR DETAILS OBVIOUSLY OMITTED SHALL BE PROVIDED AT NO ADDITIONAL COST TO THE OWNER. 4. THE CONTRACTOR IS REQUIRED TO BID, AS SPECIFIED, ON THE DRAWINGS .WITHOUT DEVIATION. THIS CONTRACTOR IS INVITED TO SUBMIT SUBSTITUTIONS FROM THE BASE BID, ONLY IF THE SUBSTITUTIONS ARE APPROVED BY THE OWNER AND ENGINEER /ARCHITECT PRIOR TO SUBMITTING THE BID. 5. IT IS THE INTENT OF THESE DOCUMENTS THAT THE M /E /P CONTRACTOR PROVIDE ALL LABOR, MATERIAL, EQUIPMENT AND TOOLS FOR THE COMPLETE INSTALLATION OF ALL WORK SHOWN ON THE PLANS AND /OR DESCRIBED HEREIN, INCLUDING ALL DEVICES, CONTROLS AND APPURTENANCES REQUIRED TO SET NEW SYSTEMS INTO OPERATION. 6. THE CONTRACTOR SHALL VERIFY ALL MOUNTING, ALL ARRANGEMENTS, HEIGHTS AND LOCATIONS PRIOR TO ROUGH -IN. ANY MENTION OF . A SPECIFIC MOUNTING ARRANGEMENT, HEIGHT OR LOCATION SHALL NOT RELIEVE THE CONTRACTOR OF THE RESPONSIBILITY TO VERIFY THE SPECIFIC REQUIREMENT FURNISHED OR THE OTHER TRADES WORKING IN THE SAME AREA. NO ADDITIONS TO THE CONTRACT SUM WILL BE PERMITTED FOR ITEMS INSTALLED IN WRONG LOCATIONS, IN CONFLICT WITH OTHER WORK, ETC. 7. SHOULD CONDITIONS NECESSITATE ANY REARRANGEMENTS, OR IF DUCTWORK CAN BE RUN TO BETTER ADVANTAGE, PREPARE AND SUBMIT SHOP DRAWINGS SHOWING THE CHANGES BEFORE PROCEEDING WITH THE WORK. IF SUCH CHANGES ARE APPROVED BY ARCHITECT /ENGINEER, THEY SHALL BECOME A PART OF THE CONTRACT AFTER THEIR APPROVAL. 8. UPON COMPLETION OF THE WORK, THE CONTRACTORS SHALL REVIEW AND CHECK THE ENTIRE PORTION OF WORK, CLEAN EQUIPMENT AND DEVICES, REMOVE SURPLUS MATERIALS AND RUBBISH FROM THE OWNER'S PROPERTY, LEAVING THE WORK IN NEAT AND CLEAN ORDER AND IN COMPLETE WORKING CONDITION. THE CONTRACTORS SHALL BE RESPONSIBLE FOR REMOVAL OF ANY CARTON, DEBRIS, ETC. FOR EQUIPMENT INSTALLED BY THE CONTRACTOR INCLUDING EQUIPMENT FURNISHED BY THE OWNER. THE ABOVE SHALL ALSO APPLY TO ALL EQUIPMENT FURNISHED BY OTHERS AND UNPACKED OR REMOVED FROM CARTON, BY THE CONTRACTORS. . 9. THE M/P CONTRACTORS IS RESPONSIBLE FOR SCHEDULING DELIVERY, . . RECEIVING, UNLOADING, UNPACKING STORING SETTING IN PLACE, AND PROTECTING FROM DAMAGE, VANDALISM, THEFT OR WEATHER DURING CONSTRUCTION FOR ALL NEW EQUIPMENT FURNISHED BY THE ELECTRICAL CONTRACTOR. 10. THE M/P CONTRACTORS SHALL PAY ALL PERMIT FEES, PLAN REVIEW FEES, LICENSE FEES, INSPECTIONS AND TAXES APPLICABLE TO THIS DIVISION AND SHALL BE INCLUDED IN THE BASE BID AS PART OF THIS CONTRACT. 11. THE M/P CONTRACTORS SHALL GUARANTEE ALL WORK AND MATERIALS FOR A PERIOD OF ONE FULL YEAR AFTER FINAL ACCEPTANCE BY THE ARCHITECT /ENGINEER AND OWNER. 12. M /E /P CONTRACTORS SHALL FURNISH CONTRACT RECORD DOCUMENTS TO THE ARCHITECT /ENGINEER BEFORE FINAL PAYMENT WILL BE ISSUED. THE CONTRACT RECORD DOCUMENTS SHALL INDICATE THE DIAGRAMMATIC INSTALLED CONDITION AND BE IN REPRODUCIBLE DRAWING FORM. 13. THE WORK INSTALLED SHALL BE IN ACCORDANCE WITH ALL LOCAL CODES AND THE LOCAL UTILITY COMPANY'S REQUIREMENTS. 14. ALL EQUIPMENT /DEVICES SHALL BE NEW AND /OR FIRST QUALITY AND IS TO BEAR THE APPROPRIATE UL OR CSA APPROVED LABELS FOR SPECIFIC PURPOSE. 15. MECHANICAL CONTRACTOR SHALL FURNISH AND INSTALL A COMPLETE TEMPERATURE CONTROL SYSTEM AS REQUIRED. 16. ALL THERMOSTATS SHALL BE MOUNTED AT +54" ABOVE FINISHED FLOOR (UNLESS OTHERWISE SPECIFIED). THERMOSTATS SHALL NOT INTERFERE WITH SHELVING, VENDING MACHINES, OTHER FIXTURES OR CONTROLS. 17, THE CONTRACTOR SHALL BE LICENSED, BONDED, INSURED AND CAPABLE OF PERFORMING QUALITY WORKMANSHIP. THIS CONTRACTOR GUARANTEES ALL OF HIS WORK AND MATERIALS FOR A PERIOD OF ONE (1) FULL YEAR AND FINAL ACCEPTANCE BY THE OWNER AND ENGINEER. 18. THE MECH & PLMG CONTRS SHALL SUBMIT SHOP DRAWINGS (ONE SEPIA AND. THREE PRINTS) PRIOR TO THE START OF INSTALLATION FOR • . OWNER /ARCHITECT /ENGINEER APPROVAL. . 19. THE M /E /P CONTRACTORS SHALL FURNISH AS -BUILT DRAWINGS TO THE OWNER /ENGINEER BEFORE FINAL PAYMENT WILL BE ISSUED. THE AS -BUILT DRAWINGS SHALL BE SUBMITTED IN REPRODUCIBLE FORM. 20. THE M /E /P CONTRACTORS SHALL BE RESPONSIBLE FOR THE STARTUP OF ALL HEATING, VENTING, AND AIR - CONDITIONING EQUIPMENT. 21. THE M /E /P CONTRACTORS SHALL PROVIDE A COMPETENT OPERATING TECHNICIAN TO INSTRUCT THE OWNER IN THE OPERATION AND MAINTENANCE OF THE NEW EQUIPMENT. 22. DO ALL CUTTING AND PATCHING (TO ORIGINAL STATE) OF BUILDING MATERIALS AS REQUIRED FOR INSTALLATION OF A COMPLETE WORKABLE SYSTEM. 23. THIS CONTRACTOR SHALL FURNISH AND INSTALL ALL SLEEVES THRU WALLS AND CORING THRU FLOORS. 24. PLUMBING CONTRACTOR SHALL VERIFY EXACT LOCATION OF ALL EXISTING SANITARY, STORM AND WATER SUPPLY ON THE SITE PRIOR TO THE PERFORMANCE OF ANY WORK. . 25. PLUMBER SHALL PROVIDE SERVICE VALVES AT ALL BRANCH SUPPLY PIPING. SUCH SERVICE VALVES SHALL BE LOCATED ACCESSIBLY ABOVE THE CEILING. 26. PLUMBER SHALL BEFORE PLACING WATER SYSTEM IN OPERATION, CHLORINATE ENTIRE SYSTEM IN ACCORDANCE WITH THE REQUIREMENTS OF STATE AND LOCAL CODE AUTHORITY. PLUMBER TO SUPPLY CERTIFICATE OF COMPLIANCE. 27, ALL NEW SANITARY PIPING SHALL BE GIVEN A FULL STATIC PRESSURE TEST. METHOD OF TEST AND REQUIREMENTS TO BE MET SHALL BE AS PER THE LOCAL CODE REQUIREMENTS. BY PLUMBER. 28. PLUMBING CONTRACTOR SHALL BE RESPONSIBLE FOR THE, PUMPING AND DRAINING OF TRENCHES OR PITS NECESSARY FOR THE INSTALLATION OF HIS WORK. 29. THE GENERAL CONDITIONS AND SUPPLEMENTARY GENERAL CONDITIONS SHALL BE CONSIDERED AS PART OF THIS SPECIFICATION. 30. ALL WORK TO BE IN ACCORDANCE WITH THE RULES AND REGULATION OF THE LOCAL CODE AUTHORITIES AND THE MOST RECENT EDITION OF NATIONAL ELECTRIC CODE. 31 . CONTRACTOR SHALL FILE PLANS WITH AND OBTAIN APPROVALS FROM MUNICIPAL AGENCIES. ALL PERMITS AND CERTIFICATES OF INSPECTION SHALL BE OBTAINED AND PAID FOR BY THE CONTRACTOR. PERTINENT CERTIFICATES SHALL BE DELIVERED TO THE OWNER'S REPRESENTATIVE, PRIOR TO FINAL BILLING. 32. ELECTRICAL CONTRACTOR SHALL RECORD ALL FIELD CHANGES IN HIS WORK AS THE JOB PROGRESSES; AN ACCURATE RECORD. OF ALL WORK AS ACTUALLY INSTALLED. UPON COMPLETION OF THE WORK AND BEFORE FINAL PAYMENT IS AUTHORIZED, SHALL TURN OVER TO THE OWNER'S REPRESENTATIVE A RECORD SET OF PRINTS SHOWING THESE CHANGES. 33. SUBMIT MATERIAL LISTS AND. SHOP DRAWINGS FOR MAJOR EQUIPMENT TO THE OWNER'S REPRESENTATIVE FOR REVIEW. SUBMITTALS SHALL BE IN ACCORDANCE WITH GENERAL CONDITIONS AND SHALL BEAR THE STAMP OF THE ELECTRICAL CONTRACTOR SHOWING THAT HE HAS REVIEWED AND APPROVED THEM. LACK OF SUCH CONTRACTOR'S APPROVAL WILL BE CAUSE FOR REJECTION WITHOUT REVIEW BY THE OWNER. 34. THIS CONTRACTOR SHALL DO ALL CUTTING, CHASING, OR CHANNELING AND PATCHING REQUIRED FOR ANY WORK HEREIN SPECIFIED. ALL OPENINGS THROUGH STRUCTURALLY SUPPORTED SLABS MUST BE CORE - BORED, SLEEVED, GROUTED, SEALED AND MADE WATERPROOF. SLEEVES MUST EXTEND AT LEAST 2" AFF. ALL SLEEVES, OPENINGS, ETC. THROUGH FIRE RATED WALLS AND FLOORS SHALL BE SEALED AFTER CONDUIT INSTALLATION TO RETAIN FIRE RATING. 35. ALL ELECTRICAL WORK SHALL BE INSTALLED SO AS TO BE READILY ACCESSIBLE FOR OPERATING, SERVICING, MAINTAINING AND REPAIR. HANGERS SHALL INCLUDE ALL MISCELLANEOUS STEEL, SUCH AS CHANNELS, RODS, ETC., NECESSARY FOR THE INSTALLATION OF WORK AND SHALL BE SECURED TO THE BUILDING STRUCTURE, NOT TO PIPING OR DUCTWORK. ALL CONDUIT SHALL BE CONCEALED WHERE POSSIBLE. EXPOSED CONDUIT SHALL BE RUN IN STRAIGHT LINES . PARALLEL WITH OR AT RIGHT ANGLES TO COLUMN LINES AND SEPARATED AT LEAST 3" FROM WATER LINES WHEREVER THEY RUN ALONG SIDE OR ACROSS SUCH LINES. 36. EVERY PART OF THE INSTALLATION SHALL BE TESTED, OPERATED AND LEFT IN PERFECT WORKING ORDER. SHOULD TESTING REVEAL ANY OTHER DEFECTS, PROMPTLY CORRECT SUCH DEFECTS AND RERUN TESTS UNTIL THE ENTIRE INSTALLATION IS SATISFACTORY IN ALL RESPECTS. 37. GUARANTEE: CONTRACTOR IS TO GUARANTEE ALL WORK FOR A PERIOD OF ONE YEAR AFTER THE DATE OF ACCEPTANCE OF THE PROJECT BY THE OWNER. IT IS UNDERSTOOD BY HIS ACCEPTANCE OF THE CONTRACT THAT THIS CONTRACTOR WILL MAKE GOOD ANY AND ALL WORK WHICH IN ANY WAY HAS BECOME DEFECTIVE AS TO THE QUALITY OF MATERIALS AND WORKMANSHIP FOR ANY CAUSE OTHER THAN ORDINARY WEAR AND TEAR. FOR THE SAME PERIOD, ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO THE PREMISES CAUSED BY DEFECTS IN WORKMANSHIP OR IN THE WORK OR EQUIPMENT FURNISHED AND /OR INSTALLED BY HIM. 38. THE CONTRACTOR, BEFORE FINAL ACCEPTANCE BY THE OWNER WILL BE GRANTED, SHALL CLEAN ALL LIGHTING FIXTURES, DEVICE PLATES, SERVICE FITTINGS AND OTHER ITEMS FURNISHED UNDER THIS CONTRACT. HE SHALL INSURE THAT ALL DIRECTORIES ARE IN PLACE WITH COMPLETED OR REVISED SCHEDULES AND ALL IDENTIFICATIONS AND MARKINGS OF EQUIPMENT, CABLES AND OTHER ITEMS ARE COMPLETED. 39. THIS CONTRACTOR SHALL COORDINATE SEQUENCE OF WORK WITH ALL OTHER TRADES. CONTRACTOR SHALL VERIFY VOLTAGE OF MECHANICAL EQUIPMENT AND FLUORESCENT FIXTURE BALLASTS, PRIOR COMMENCING ANY WORK. NO REMOVALS SHALL BE MADE WITHOUT OWNER'S APPROVAL. ALL EXISTING EQUIPMENT, MATERIALS, ETC. THAT ARE NOT TO BE REUSED SHALL BE REMOVED COMPLETELY AND DISPOSED OF BY THIS CONTRACTOR. 40. THIS CONTRACTOR SHALL MAKE ARRANGEMENTS FOR TEMPORARY POWER AND SHALL PAY THE COST FOR THE UTILITY CONNECTION AND SHALL BE RESPONSIBLE FOR THE PROPER MAINTENANCE OF THE TEMPORARY WORK AND. FOR THE REMOVAL OF SAME. CONTRACTOR SHALL PAY ALL UTILITY CHARGES IN CONNECTION WITH THE TEMPORARY POWER. CONTRACTOR SHALL PROVIDE GROUND FAULT PROTECTION FOR ALL POWER EQUIPMENT USED ON THE PREMISES DURING CONSTRUCTION. 41. SCOPE OF WORK CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, SUPPLIES, EQUIPMENT AND FEES REQUIRED TO COMPLETELY INSTALL, TEST AND PLACE THE HEREIN SPECIFIED EQUIPMENT, COMPONENTS, CONTROLS, AND SYSTEMS IN SERVICE. COMPLETE POWER AND LIGHTING DISTRIBUTION SYSTEMS INCLUDING ALL PANELS AND COMPLETE BRANCH CIRCUIT WIRING SYSTEM COMPLETE UTILITY MOTOR WIRING SYSTEMS (EXCEPT AS NOTED) COMPLETE LIGHTING FIXTURE INSTALLATION COMPLETE TELEPHONE CONDUIT SYSTEM. CONDUIT FROM POINT OF CONNECTION TO LANDLORD'S SYSTEM AND ALL TERMINAL DEVICES, BOXES, CONDUIT, PLATES, ETC. TEMPORARY ELECTRICAL SERVICE AS REQUIRED FOR CONSTRUCTION WIRING AND FINAL CONNECTION TO ALL SIGNS AND GRAPHICS, FURNISHED BY THE OWNER PROVISIONS FOR • FIRE ALARM /SMOKE EVACUATION SYSTEM AND EXTENSION TO LANDLORD'S SYSTEM TESTING OF ALL CABLES AND CIRCUIT WIRING AFTER INSTALLATION TESTING OF ALL ELECTRICAL EQUIPMENT WARRANTY OF ALL WORK FOR A PERIOD OF ONE YEAR FROM DATED OF PROJECT CLOSE -OUT 42. ELECTRICAL SERVICE PROVIDE ELECTRICAL AS INDICATED ON THE DRAWING. ALL WORK NOT SPECIFICALLY NOTED AS BEING BY THE LANDLORD OR THE POWER COMPANY SHALL BE PROVIDED BY THE ELECTRICAL CONTRACTOR. CLOSELY COORDINATE ENTIRE INSTALLATION WITH THE POWER COMPANY. CONTRACTOR SHALL MAKE ARRANGEMENTS WITH THE LOCAL UTILITY FOR INSTALLATION OF METERING. 43. CONTRACTOR SHALL MAKE ARRANGEMENTS WITH THE LOCAL TELEPHONE UTILITY FOR TELEPHONE SERVICE TO THE SPACE, CONDUIT SYSTEM FOR TELEPHONE DISTRIBUTION TO THE LEASED PREMISES SHALL BE PROVIDED WHERE REQUIRED FOR UTILITY COMPANY WIRES. COORDINATE INSTALLATION OF TELEPHONE WORK AND INSTALL ALL CONDUIT FOR TELEPHONE SYSTEM. OUTLET BOXES SHALL BE 4" SQUARE MINIMUM WITH SINGLE DEVICE COVER AND TELEPHONE PLATE. PROVIDE INTERIOR TYPE 4 -D PLYWOOD 24" X 24" TO SERVE AS TELEPHONE TERMINAL BOARD 44. FURNISH ALL LABOR, MATERIALS, EQUIPMENT AND TOOLS TO PERFORM ELECTRICAL WORK SHOWN, NOTED OR SCHEDULED FOR A COMPLETE AND FINISHED INSTALLATION. 44.1 THE WORD "PROVIDE" AS USED HEREIN MEANS TO FURNISH AND INSTALL COMPLETE. 44.2 MATERIALS, PRODUCTS AND EQUIPMENT, INCLUDING COMPONENTS THEREOF, SHALL BE NEW AND SUCH AS APPEARS ON THE UNDERWRITER'S LABORATORY LIST OF APPROVED ITEMS ANC SHALL MEET THE REQUIREMENTS OF RECOGNIZED STANDARDS. 44.3 EQUIPMENT SHALL BE SIZED IN CONFORMITY WITH REQUIREMENTS OF THE NATIONAL ELECTRICAL CODE, THE LOCAL AND STATE CODES 45. CONDUIT SHALL BE STANDARD STEEL, RIGID, IMC OR EMT (THIN WALL) ACCORDING TO CODE REQUIREMENTS. CONDUIT SHALL BE CONCEALED IN FINISHED AREAS, EXCEPT AS OTHERWISE APPROVED BY OWNER'S REPRESENTATIVE. 46. RACEWAYS SHALL BE SURFACE METAL TYPE OF THE SIZE AND CHANNEL REQUIRED FOR SERVICE, CONSTRUCTED OF GALVANIZED STEEL WITH SNAP -ON COVERS, WITH 1/8" MOUNTING SCREW KNOCKOUTS IN BASE APPROXIMATELY 8" O.C. PROVIDE FITTINGS INDICATED WHICH MATCH AND MATE WITH RACEWAY. FINISH WITH MANUFACTURER'S STANDARD PRIME COATING SUITABLE FOR PAINTING. 47. ALL CONDUCTORS SHALL BE SOFT DRAWN, ANNEALED COPPER, WITH 600V INSULATION: 47.1 #10 AND SMALLER - SOLID WITH SINGLE BRAID OR STRANDED # 8 AND LARGER - STRANDED WITH AT LEAST DOUBLE BRAID. MINIMUM WIRE SIZE SHALL BE #12, EXCEPT #14 MAY BE USED FOR CONTROL APPLICATIONS. 47.2 ALL WIRE AND CABLE SHALL BE NEW AND SHALL BE BROUGHT TO THE SITE IN UNBROKEN PACKAGES. 47.3 GENERAL WIRING SHALL HAVE THW, THHN OR THWN INSULATION. 47.4 ALUMINUM CONDUCTORS ARE NOT PERMITTED FOR BRANCH CIRCUIT WIRING. 47.5 WIRES SHALL BE COLOR CODED IN KEEPING WITH NEC STANDARDS 48. OUTLET BOXES AND COVERS SHALL BE ONE PIECE, GALVANIZED OR SHERARDIZED STEEL, KNOCK -OUT TYPE W /FIXTURE STUDS AS REQ. JUNCTION BOXES, PULL BOXES AND COVERS SHALL BE GALVANIZED STEEL, CODE GAUGE AND SIZE. 49. WIRING DEVICES: WALL SWITCHES, SINGLE POLE, DOUBLE POLE, AND THREE WAY SHALL BE GENERAL DUTY, FLUSH, TOGGLE SWITCHES; SPECIFICATION GRADE, 20A, 120/277V, WITH SCREW TERMINALS: MANUFACTURES SHALL BE HUBBELL, BRYANT, PASS AND SEYMORE, OR LEVITRON. GENERAL DUTY DUPLEX RECEPTACLES SHALL BE 2 -POLE, 3 -WIRE GROUNDING TYPE, SPECIFICATION GRADE, 20A, 125V, NEMA 5 -20R UNLESS OTHERWISE INDICATED. MANUFACTURERS SHALL BE HUBBELL, BRYANT, PASS AND SEYMORE, OR LEVITRON. GROUND FAULT INTERRUPTER RECEPTACLE SHALL BE GENERAL DUTY, DUPLEX RECEPTACLES, GROUND FAULT CIRCUIT INTERRUPTER, FEED - THROUGH TYPE, CAPABLE OF PROTECTING CONNECTED DOWNSTREAM RECEPTACLES ON A SINGLE CIRCUIT, GROUNDING TYPE UL -RATED CLASS A, GROUP 1, 20A, 120V, 60 HZ; WITH SOLID -STATE GROUND FAULT SENSING AND SIGNALING; WITH 5 MILLIAMPERES GROUND -FAULT TRIP LEVEL; IN NEMA 5 -15R CONFIGURATION. MANUFACTURERS SHALL BE HUBBELL, BRYANT, PASS AND SEYMORE, OR LEVITRON. DUPLEX ISOLATED GROUND TYPE RECEPTACLE SHALL BE 2 -POLE, 4 -WIRE, 15A STRAIGHT BLADE DEVICE WITH SEPARATE ISOLATED GROUND AND BUILDING GROUND CONNECTIONS, IN NEMA 5 -15R CONFIGURATION, AS MANUFACTURED BY HUBBELL IG -5362. ANY RECEPTACLE THAT IS INSTALLED AT OF BELOW 37 INCHES SHALL BE INSTALLED GROUND UP AND ANY RECEPTACLE THAT IS INSTALLED AT OR ABOVE 38 INCHES SHALL BE INSTALLED GROUND DOWN. SEE DETAIL. 50. THIS CONTRACTOR SHALL PROVIDE, INSTALL AND CONNECT A COMPLETE SYSTEM OF GROUNDING FOR ALL EQUIPMENT AND STRUCTURES. A GOOD MECHANICAL AND ELECTRICAL CONNECTION SHALL BE MADE WITH APPROVED GROUNDING CONNECTORS. ELECTRICAL SYSTEM AND EQUIPMENT GROUNDS SHALL COMPLY WITH ALL THE LOCAL, STATE AND NEC CODES AND REGULATIONS. PANELS, CONDUIT SYSTEMS, MOTOR FRAMES, LIGHTING FIXTURES AND OTHER EQUIPMENT THAT ARE A PART OF THIS INSTALLATION SHALL BE SECURELY GROUNDED BOTH MECHANICALLY AND ELECTRICALLY IN ACCORDANCE WITH ALL LOCAL AND STATE CODES. MAIN GROUNDING SYSTEM SHALL BE SIZED TO CONFORM WITH SECTION 250, TABLE 250 -66 OF THE NATIONAL ELECTRICAL CODE. PROVIDE CONDUIT TO GROUND WIRE FROM DAMAGE TO AN AREA 6 FT. ABOVE FLOOR. PROTECT MAKE ALL JOINTS AND CONNECTIONS OF THE CONDUIT SYSTEM TIGHT TO MAINTAIN CONTINUITY OF MECHANICAL AND ELECTRICAL GROUND THROUGHOUT ENTIRE SYSTEM. GROUND ALL 3 WIRE RECEPTACLES TO THE OUTLET BOXES. GROUND NEUTRAL FROM THE TRANSFORMER CONNECTED TO WATER LINE. GROUND CONDUCTOR SHALL BE SUPPLIED IN ALL NON- METALLIC CONDUIT. 51, LIGHTING PANEL BOARD SHALL BE 3- PHASE, 4 -WIRE DISTRIBUTED PHASE TYPE WITH SOLID NEUTRAL GROUND LUG, GROUND BUS AND NUMBER OF CIRCUIT BREAKERS AS SHOWN ON THE PANEL SCHEDULE. BUSWAYS SHALL BE HARD DRAWN COPPER. CABINET SHALL BE CONSTRUCTED OF CODE GAUGE STEEL WITH HINGED DOOR HAVING DIRECTORY CARD, NEATLY AND PROPERLY INSCRIBED AND SET IN FRAME WITH TRANSPARENT COVER. ALL BREAKERS SHALL BE BOLTED TYPE, THERMAL MAGNETIC WITH ALL TWO OR THREE POLE BREAKERS HAVING COMMON TRIP. CIRCUIT BREAKERS SHALL BE RATED FOR MINIMUM 10,000 AMP SYMMETRICAL SHORT CIRCUIT CURRENT AT 120/208V. CIRCUIT BREAKERS SERVING LIGHTING CIRCUITS SHALL BE RATED FOR SWITCH SERVICE. PANELBOARDS AND BREAKERS SHALL BE AS MANUFACTURED BY SQUARE -D OR EQUAL. PANEL SHALL BE CIRCUITED SO THAT THE LOAD IS DISTRIBUTED EVENLY ACROSS ALL THREE PHASES. 52. PROVIDE SAFETY AND DISCONNECT SWITCHES, FUSED OR NON- FUSED, AS CALLED FOR ON DRAWING AND AS REQUIRED BY THE LOCAL AND STATE CODES. SWITCHES SHALL BE HEAVY DUTY, LOAD AND HORSEPOWER RATED AS MANUFACTURED BY SQUARE -D, GENERAL ELECTRIC, OR EQUAL. SWITCH ENCLOSURE TO BE SUITABLE FOR APPLICATION. FURNISH AND INSTALL DUAL ELEMENT CURRENT LIMITING FUSES OF TYPE AND AMPACITY DESIGNED TO PROTECT SYSTEM AGAINST AVAILABLE SHORT CIRCUIT FAULT CURRENT. 53. IF REQUIRED: PROVIDE DRY -TYPE TRANSFORMER WHICH SHALL BE COMPLETELY ENCLOSED EXCEPT FOR VENTILATING OPENINGS WITH KVA AND VOLTAGE RATINGS AS CALLED FOR ON THE DRAWING AS MANUFACTURED BY SQUARE -D. TRANSFORMER SHALL HAVE A MINIMUM OF CLASS 155 INSULATION SYSTEM, AND A MINIMUM OF (4) 2 -1/2 % TAPS BELOW AND (2) 2 -1/2 % TAPS ABOVE RATED PRIMARY VOLTAGE. SOUND LEVEL SHALL BE LOW AND INSTALLATION SHALL INCLUDE VIBRATION DAMPENING MOUNTS AND FLEXIBLE STEEL CONDUIT FOR PRIMARY AND SECONDARY. 54. LIGHTING FIXTURES: THE CONTRACTOR SHALL PROVIDE A NEW LIGHTING FIXTURE OF THE TYPE SPECIFIED FOR EACH LIGHTING OUTLET SHOWN WITH COMPLETE LAMPS OR TUBES. ALL FIXTURES SHALL BE HUNG AND MOUNTED IN PLACE, PROPERLY WIRED, TESTED AND LEFT READY FOR OPERATION. 55. PAINTING OF ELECTRICAL CONDUITS, ETC. IF REQUIRED, WILL BE BY GENERAL CONTRACTOR. 56. RECEPTACLES, SWITCHES, AND COVER PLATES IN CUSTOMER AREAS ARE TO MATCH THE SURROUNDING WALL COLOR. ALL RECEPTACLES AND SWITCHES IN PREP AREA AND RESTROOMS ARE TO BE WHITE WITH STAINLESS STEEL COVER PLATES 57. FINALLY: IT IS THE INTENT THAT THE FOREGOING WORK SHALL BE COMPLETE IN EVERY RESPECT AND THAT ANY MATERIAL OR WORK NOT SPECIFICALLY MENTIONED OR SHOWN ON THE DRAWINGS, BUT NECESSARY TO FULLY COMPLETE THE WORK SHALL BE FURNISHED. THE LOCATION OF RECEPTACLES AND FIXTURES SHOWN ON THE DRAWING IS APPROXIMATE AND THE OWNER SHALL HAVE THE RIGHT TO RELOCATE ANY RECEPTACLES OR FIXTURES BEFORE THEY ARE INSTALLED WITHOUT ADDITIONAL COST. 58. NO ROMEX OR BX WILL BE PERMITTED. 59. ALL WIRE SHALL BE INSTALLED IN THIN WALL (E.M.T.) CONDUIT UNLESS OTHERWISE NOTED. MINIMUM SIZE SHALL BE 3/4" EXCEPT FOR DROPS FOR DEVICES, SWITCH LEGS, TEMPERATURE CONTROL CONDUITS, WHERE INDICATED OR AS CALLED FOR ON DRAWINGS. 60. ALL THIN WALL FITTINGS SHALL BE OF THE STEEL COMPRESSION GLAND TYPE. 61. ALL UNDER FLOOR, UNDERGROUND OR EXPOSED -TO- WEATHER CONDUIT SHALL BE HEAVY WALL GALVANIZED RIGID STEEL (G.R.S.), MINIMUM 3/4 ". 62. ALL CONDUITS 2" OR LARGER SHALL BE GALVANIZED RIGID STEEL OR INTERMEDIATE METAL CONDUIT (I.M.C.). 63. ELECTRICAL CONTRACTOR SHALL INSTALL SIZE OF CONDUIT SHOWN AND AS SCHEDULED ABOVE AND SHALL NOT REDUCE SIZING OF CONDUITS TO SUIT WIRE FILL CAPACITY. 64. ALL CONDUIT FASTENERS, STRAPS, SUPPORTS ETC. MUST BE "BOLT-ON" GALVANIZED STEEL ON EXPOSED CONSTRUCTION AND IN WET AREAS. SNAP -ON BLACK METAL "CADDY" CUPS IN METAL PARTITION WALLS AND ABOVE SUSPENDED CEILINGS WILL BE PERMITTED. ALL FASTENERS, STRAPS, CLIPS, ETC. SHALL BE UL LISTED FOR THEIR USE. 65. NO CONDUITS SHALL BE ROUTED THROUGH HVAC AIR DUCTS. 66. ALL CONDUIT RACEWAYS SHALL BE CONCEALED IN OR WITHIN: WALLS, CEILING CAVITY, ROOF CONSTRUCTION (WHERE APPROVED), SLAB, GRADE, ETC. UNLESS OTHERWISE NOTED. ANY RACEWAY THAT IS TO BE ROUTED EXPOSED SHALL BE APPROVED BY THE ARCHITECT /ENGINEER PRIOR TO INSTALLATION. ALL CONDUIT SHALL BE ROUTED PARALLEL OR PERPENDICULAR TO WALLS AND STRUCTURAL MEMBERS WITH 90' F BENDS WHERE REQUIRED AND SHALL. BE RACKED. PULL AND JUNCTION BOXES SHALL BE HELD TO A MINIMUM. 67. NO WIREWAY, THROUGH OR JUNCTION SHALL BE UTILIZED WHERE MORE THAN 8 CONDUITS ARE ENTERING OR LEAVING. MULTIPLE WIREWAYS, TROUGHS OR JUNCTIONS SHALL BE UTILIZED. IN NO CASE SHALL FEED OR CONDUIT OR CABLING BE MIXED WITH BRANCH CONDUIT. 68. NO CONDUITS SHALL BE ROUTED ON ROOF. ELECTRICAL CONTRACTOR SHALL COORDINATE ROOF PENETRATIONS WITH MECHANICAL PIPE CURBS. WHERE CONDUIT MUST BE RUN ON ROOF, IT SHALL BE RACKED WITH OTHER TRADES WHERE POSSIBLE OR PROVIDED WITH ITS OWN ROOF RACK SUPPORT SYSTEM WITH PROPER ROOF PLATE SO AS NOT TO CAUSE DAMAGE TO ROOF COVERING. 69. ELECTRICAL CONTRACTOR SHALL FIREPROOF ALL CONDUIT OPENINGS BETWEEN FLOORS AND ANY INTERSPACE FIRE SEPARATION BLOCK WALLS WITH AN ENGINEER APPROVED UL LISTED FIRE RETARDANT MATERIAL. 70. ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL SLEEVES THRU WALLS AND CORING THRU FLOORS. ELECTRICAL CONTRACTOR SHALL WEATHERPROOF ALL PENETRATIONS THRU FOUNDATION AND EXTERIOR WALLS. 71. FINAL EQUIPMENT CONNECTION TO PILOT CONTROL DEVICES SHALL BE MADE WITH 1' -0" MINIMUM LENGTH OF FLEXIBLE CONDUIT CONNECTION (IE. SOLENOID VALVES, MOTORIZED DAMPERS, ETC.). ELii Ob50 RECEIVEQ CITY OF TUK LA JUL 19 2011 PERMIT CENTER sommessammisami Abossein Engineering, L.L.C. MECHANICAL - ELECTRICAL CIVIL - LEED FIRE PROTECTION 2100 112TH AVE. NE BELLEVUE, WA 98004 PH: (425) 462-9441 FAX: (425) 462 -9451 E -Mail: cservice @abossein.com www.abossein.com iiiic M N 1114 cs w-vi 01 la 0 WA Ir ax H W g Pi 111MI a a a �A IA 0 Revisions ISSUE FOR JJ REVIEW 06/30/11 OISSUE FOR PERMIT/ LL REVIEW 07/15/11 ARCHITECT SPECIFICATIONS I MEN CERTIFY THAT TIES£ PLANS HAVE TEEN PRE- PARED UNDER NT SUPERVISION MD THAT ID 11E BEST OF NY MIDGE, TIE SNE UM'LT UDR ALL RUES, REGULATIONS MID II DINANCES OF HIM A. Vg RELATING TO STRUCTURES AND BUILDINGS. Drawn By Checked By Scale 1/4"=1'-0" Date 06/30/2011 rilo -21 00. Sheet No. VI =P -1 (oF 2) HEVIEWED.FOR COMPLIANCE WITH NFPA 70 - NEC JUL 23 2011 City of Tukwila BUILDING DIVISION E.L11--06i 5-0 RECEIVED CITY OF TUKWILA JUL 1 U 1011 PERMIT CENTER Abossein Engineering, L.L.C•. MECHANICAL - ELECTRICAL CIVIL - LEED FIRE PROTECTION 2100 112TH AVE. NE BELLEVUE, WA 98004 PH: (425) 462-9441 FAX: (425) 462-9451 E -Mail: cselvice @abossein.com www.abossein.com ENEENERBEEMBEIMI y 0 N E4ok ''` wry+ WA. 0 01 NI%TA 'la' h H O: (Js o o Revisions ISSUE FOR 006/30/11 ISSUE FOR OLL REVIEW JJ REVIEW PERMIT/ 07/15/11 ARCHITECT I MY CERTIFY NAT THESE FLANS HAVE BEEN ME- NDED UNDER NY SU?ERVISIQI AND THAT 10 TIE BEST OF NY IDOVLEDGE, THE SAIi COMPLY HMI ALL RUES, REGULATIONS AND ORDINANCES OF TUKVILA. VA RELATING TO STRUCTURES AND BUILDINGS. Drawn By Checked By Scale 1/4 " =1' -0" Date 06/30/2011 Job No. 1 1 -2100 Sheet N P -2 (OF 2) MECHANICAL SYMBOL LIST MAT'L MECH. MAT L &PROCEDURE NOTES: MECHANICAL EQUIPMENT NOTES: PLUMBING MATT. & PROC. NOTES SYMBOL DESCRIPTION DUCTWORK: 1. ALL DUCTWORK SHALL BE FABRICATED FROM GALVANIZED METAL IN ACCORDANCE WITH SMACNA STANDARDS FOR LOW AND MEDIUM PRESSURE DUCT CONSTRUCTION, DUCT SIZES. SHOWN INDICATE INSIDE DIMENSIONS. 2. ALL DUCTWORK ACCESS DOORS SHALL BE OF SUFFICIENT SIZE TO PERMIT EASY ACCESS AND THE SERVICING OF DAMPERS, CONTROLS, DEVICES, ETC. ACCESS DOORS SHALL BE VENTLOK COMPLETE WITH #50 HINGES WITH BRASS PINS, #100 LATCHES, DOOR GASKETS, ETC. DOORS LOCATED IN INSULATED DUCTWORK SHALL HAVE 1/2" THICK FIBERGLASS INSULATION BETWEEN TWO THICKNESS OF SHEET . METAL. 3. DUCTWORK SHALL COMPLY WITH ALL LOCAL AND STATE REGULATIONS REGARDING FIRE STOPPING, PROOFING AND DAMPERING. ACCESS DOORS OF SUFFICIENT SIZE FOR EASY ACCESS AND SERVICING SHALL BE PROVIDED AT ALL FIRE DAMPERS. 4. AIR VELOCITY IN LOW PRESSURE MAIN SUPPLY TRUNKS SHALL NOT EXCEED 1500 FPM, IN SUPPLY BRANCHES VELOCITY SHALL NOT EXCEED 1200 FPM, AND IN RETURN AIR DUCT VELOCITY SHALL NOT EXCEED 1200 FPM. 5. MECHANICAL CONTRACTOR TO CORDINATE DUCT INSTALLATION WITH BRICK /TILE INSTALLERS TO ENSURE PROPER CLEARANCES. DUCT INSULATION: 1. ALL SUPPLY DUCTWORK FROM HEATING /COOLING UNITS SHALL BE LINED WITH 1 -1/2 LB DENSITY, 1/2" THICK FIBERGLASS DUCT LINER. DUCT LINING AND ADHESIVE SHALL BE IN CONFORMANCE WITH NFPA NO. 90A STANDARDS. 2. ALL RETURN DUCTWORK WITHIN 10'-0" OF HEATING / COOLING UNITS SHALL BE LINED WITH 1 -1/2 LB DENSITY, 1/2 THICK FIBERGLASS 1/2" DUCT LINER. DUCT LINING AND ADHESIVE SHALL BE IN CONFORMANCE WITH NFPA NO. 90A STANDARDS. 3. ALL EXHAUST DUCTWORK ON THE SUCTION SIDE OF EXHAUST FANS SHALL BE LINED WITH 1 -1/2 LB DENSITY, 1/2" THICK FIBERGLASS DUCT. LINER, FOR A MINIMUM DISTANCE OF 10' -0 ". 4. ALL DUCT INSULATION SHALL HAVE A FLAME SPREAD RATING OF NOT MORE THAN 25 AND A SMOKE- DEVELOPED RATING OF NOT MORE THAN 50. DUCT SMOKE DETECTOR: 1. DUCT SMOKE DETECTORS SHALL BE INSTALLED IN SUPPLY AND RETURN DUCTS ON ALL A/C EQUIPMENT 2000 CFM OR LARGER. ELECTRICAL CONTRACTOR TO SUPPLY AND WIRE DETECTOR. MECHANICAL CONTRACTOR TO DUCT MOUNT DETECTOR. ELECTRICAL AND MECHANICAL CONTRACTORS TO COORDINATE SIZES AND TYPES FOR INSTALLATION. GAS PIPING: 1. THIS CONTRACTOR SHALL CONTACT LOCAL GAS COMPANY TO COORDINATE: NEW GAS LOAD, METER LOCATION, AND PRESSURE REGULATOR ASSEMBLY. 2. GAS PIPING SHALL BE SCHED. 40 BLACK CARBON STEEL, WITH MALLEABLE IRON 150 LB. FITTINGS. GAS PIPING LARGER THAN 2" SHALL BE WELDED, PIPING UNDER 2" SHALL . BE THREADED CONNECTIONS. 3. GAS COCKS (CRANE #254 WITH CHECK OR EQUAL), AND DIRT LEGS (MIN. 6 ") SHALL BE INSTALLED IN THE PIPING TO EACH PIECE OF GAS FIRED EQUIPMENT. 4. BEFORE FINAL EQUIPMENT CONNECTIONS ARE MADE, PNEUMATICALLY TEST GAS PIPING AT 15 PSIG AIR PRESSURE. THE PRESSURE TEST SHALL BE DEEMED ACCEPTABLE IF THE PIPING SYSTEM HOLDS THE PRESSURE FOR. FOUR (4) HOURS. TESTING SHALL BE WITNESSED BY OWNER. 1. ALL EQUIPMENT /DEVICES SHALL BE NEW AND OF FIRST RATE QUALITY (UNLESS OTHERWISE SPECIFIED) AND IS TO BEAR THE APPROPRIATE ( ) AGA, CSA OR UL APPROVED LABELS, LISTINGS, AND CERTIFICATIONS FOR THE SPECIFIC DESIGN PURPOSE. 2. ALL EQUIPMENT SOUND LEVELS SHALL NOT EXCEED 50 DB AT PROPERTY LINE. 3. ALL INTERCONNECTING WIRING AT UNIT SHALL BE FACTORY PREWIRED AND REQUIRE ONLY ONE (1) POWER CONNECTION TO THE UNIT BY THE ELECTRICAL CONTRACTOR. DISCONNECT SWITCH SHALL BE BY THE ELECTRICAL CONTRACTOR UNLESS NOTED OTHERWISE. 4. ELECTRICAL CONTRACTOR SHALL FURNISH COMBINATION MAGNETIC STARTER-DISCONNECT SWITCHES AS REQUIRED (WEATHERPROOF FOR EQUIPMENT LOCATED OUTSIDE OF BUILDING). THE ELECTRICAL CONTRACTOR WILL INSTALL. 5. SUBMIT EIGHT (8) COPIES OF EACH CATALOG CUT, FOR THE EQUIPMENT SPECIFIED, TO THE ARCHITECT /ENGINEER FOR APPROVAL PRIOR TO. THE BEGINNING OF CONSTRUCTION. THIS CONTRACTOR SHALL ALSO ASSEMBLE PRINTED INSTRUCTIONS FOR THE OPERATION AND MAINTENANCE OF EACH ITEM INSTALLED AND BIND TOGETHER WITH EQUIPMENT CUTS AND CONTROL WIRING DIAGRAMS. SUBMIT EIGHT (8) COPIES TO THE OWNER /ARCHITECT /ENGINEER. 6. THIS CONTRACTOR SHALL FURNISH AND INSTALL ALL STRUCTURAL STEEL MEMBERS, SLEEVES, AND SHIMS REQUIRED TO LEVEL AND SUPPORT EQUIPMENT, ROOF CURBS AND EQUIPMENT SUPPORTS. MATERIALS: 1. ALL MATERIALS SHALL BE NEW, OF FIRST QUALITY AND UL LISTED FOR THE SPECIFIC DESIGN PURPOSE. 2. SANITARY, VENT AND STORM LINES SHALL BE CAST IRON AND AS PERMITTED BY THE LOCAL AND STATE CODE AUTHORITIES. PVC NOT PERMITTED WHERE DISCHARGE EXCEEDS 907 3. ALL WATER AND WASTE PIPING TO BE RUN ON WARM SIDE OF INSULATION. 4. DOMESTIC SUPPLY PIPING LOCATED ABOVE THE FINISHED FLOOR SHALL BE TYPE "L" COPPER. UNDERGROUND DOMESTIC SUPPLY PIPING SHALL BE TYPE "K" COPPER. 5. THREADED FITTINGS ON GALVANIZED STEEL PIPING SHALL BE 150# CLASS GALVANIZED MALLEABLE IRON FITTING CONFORMING TO ASTM A -197 SPECIFICATION. 6. FURNISH AND INSTALL UNIONS WHERE INDICATED OR NECESSARY FOR REPAIR OR SERVICE. UNIONS 2" AND SMALLER SHALL BE STANDARD GROUND JOINT BRASS TO IRON SEAT, MALLEABLE IRON, SCREWED. UNIONS 2 -1/2" AND LARGER SHALL BE STANDARD CAST IRON FLANGED UNIONS 125# CLASS. 7, VALVES SHALL BE MANUFACTURED BY CRANE, STOCKHAM. 8. DOMESTIC HOT WATER SUPPLY PIPING SHALL BE INSULATED WITH ONE OF THE FOLLOWING: (INSTALL AS RECOMMENDED BY MANUFACTURER). A. 1" THICK PREFORMED FIBERGLASS WITH "K" FACTOR OF 0.23 MAXIMUM AT 757. MEAN TEMPERATURE. JACKET TO BE FACTORY APPLIED KRAFT PAPER WITH VAPOR BARRIER. B. 1" THICK MOLDED RIGID PHENOLIC FOAM WITH "K" FACTOR OF 0.23 MAXIMUM AT 787 MEAN TEMPERATURE WITH FACTORY APPLIED LAMINATED ALUMINUM FOIL AND WHITE KRAFT PAPER VAPOR BARRIER JACKET. 9. DOMESTIC COLD WATER PIPING AND SUSPENDED HORIZONTAL STORM SEWERS AND ALL FITTINGS SHALL BE INSULATED WITH: (INSTALL AS RECOMMENDED BY MANUFACTURER). A. 1/2" THICK INSULATION W/ FRK WRAP FOR PIPING UP TO 1-1/4" DIAMETER. B. 1" THICK AT STORM C. SEAL BUTT & LONGITUDIAL JOINTS W/ WATERPROOF SEALANT. 10. PIPE INSULATION AT ALL PIPE HANGERS SHALL CONSIST OF INSUL- SHIELD. FIBERGLASS PIPE SUPPORTS AS MANUFACTURED BY INSUL-COUSTIC OR ARCHITECT /ENGINEER APPROVED EQUAL. 11. HANGERS SHALL BE OF STANDARD WEIGHT STEEL OR IRON ROD AND RING OR CLEVIS TYPE. PROCEDURES: 1. ALL SUSPENDED HORIZONTAL PIPING SHALL BE SUPPORTED BY HANGERS SPACED NO FURTHER THAN 8' - 0" APART (4' -0" APART FOR PVC PIPING). NO PIPING SHALL BE SELF- SUPPORTING NOR BE SUPPORTED FROM EQUIPMENT CONNECTIONS. 2. ALL PARALLEL PIPES [TWO (2) OR MORE] SHALL BE SUPPORTED ON A CHANNEL TYPE TRAPEZE HANGER. 3. SUPPORTS AND HANGERS SHALL BE INSTALLED TO PERMIT FREE EXPANSION AND CONTRACTION IN PIPING SYSTEMS UNLESS PIPE REQUIRES FIRM ANCHOR CONTROL. . 4 HORIZONTAL SOIL OR WASTE LINES SHALL BE AT A SLOPE OF NOT LESS THAN 1/8 " PER FOOT AND SHALL BE HELD CLOSE TO THE CONSTRUCTION TO MAINTAIN A MAXIMUM OF HEAD ROOM. ALL CHANGES OF DIRECTION AND JUNCTIONS SHALL BE MADE WITH "Y" FITTINGS AND 1/8" BENDS. NO LINES OF ANY KIND SHALL BE LOCATED BELOW FREEZERS. ALL DRAIN LINES SHALL BE PROTECTED FROM FREEZING. 5. HOT AND COLD WATER PIPING SHALL BE PROPERLY PITCHED TO LOW POINTS IN THE SYSTEM WHERE DRAINS SHALL BE INSTALLED. 6. 50' -OO" INTERVALS ON HORIZONTAL ARUNS, AOUT NOF� HIGH CTRAFFIC AREAS, NOT UNDER CASES) ETC. WHERE CLEANOUTS OCCUR IN CONCEALED SPACES, THEY SHALL BE PROVIDED WITH EXTENSIONS TO FLOOR ABOVE OR TO WALLS. A HAND -HOLE TEST TEE BE PLACED AT THE BASE OF EACH STACK. 7. VENT STACKS EXTENDING UP THROUGH THE ROOF SHALL BE FLASHED WITH SIX POUND SHEET LEAD. FLASHING SHALL EXTEND 12" IN ALL DIRECTIONS FROM THE VENT, CARRIED OVER AND TURNED DOWN THE INSIDE OF THE VENT. ALL SEAMS AND JOINTS OF FLASHING SHALL BE SOLDERED AND PROVEN WEATHERTIGHT. EXTEND VENTS A MIN. OF 12" ABOVE ROOF, AND 30" AWAY FROM PARAPET. 8. ALL SUPPLY PIPING TO BE RUN OVERHEAD, UNLESS NOTED OTHERWISE. 9. ALL SUPPLY PIPING TO BE A MINIMUM OF 3/4" DIA. 10. EACH FIXTURE WILL HAVE A 3/4" X 12" AIR CHAMBER. 11. PROVIDE SERVICE VALVE AT BRANCHES AND AT ALL APPLIANCES. 12, ALL FIXTURES WILL BE FURNISHED WITH INTEGRAL STOPS. 13, BURIED SANITARY AND WASTE LINES WILL BE A MINIMUM OF 4" DIA. 14. ALL FLOOR DRAINS AND FIXTURES TO BE VENTED IN ACCORDANCE WITH LOCAL CODES. 15. ALL HORIZONTAL VENT PIPING SHALL BE RUN ABOVE FINISHED CEILINGS AND SLOPED UP TOWARD MAIN STACK. 16. THE PLUMBING CONTRACTOR WILL NOT INSTALL COMBUSTIBLE PIPING MATERIAL IN OR THROUGH FIRE RATED ASSEMBLIES. 17. HORIZONTAL DRAINAGE PIPING SHALL BE PITCHED NOT LESS THAN 1/4" PER FOOT FOR PIPING 3" DIA. AND UNDER. 18. HORIZONTAL DRAINAGE PIPING SHALL BE PITCHED NOT LESS THEN 1/8" PER FOOT FOR PIPING 4 DIA. AND OVER. 19. ALL EQUIPMENT DEVICES SHALL BE INSTALLED WITH UNIONS IN SUCH A MANNER TO FACILITATE EASY REMOVAL AND MAINTENANCE OF EQUIPMENT WITHOUT DISRUPTING SERVICE AND CAUSING MAJOR PIPING REVISIONS. 20, ALL CONNECTIONS BETWEEN DISSIMILAR METALS SHALL BE MADE WITH DIELECTRIC UNIONS OR COUPLINGS. CFM CUBIC FEET OF AIR PER MINUTE DIFF DIFFUSER. EA EACH EF -# EXHAUST FAN ESP EXTERNAL STATIC PRESSURE FBO FURNISHED BY OTHERS GR GRILLE MVD MANUAL VOLUME DAMPER NK NECK OAI OUTSIDE AIR INTAKE RTU -# ROOFTOP UNIT U -CUT UNDERCUT DOOR SUPPLY DUCT UP THRU FLOOR/ ROOF ELECTRICAL SYMBOL LIST RETURN DUCT UP THRU FLOOR/ ROOF I. MANUAL VOLUME DAMPER SYMBOL DESCRIPTION + 1 A.F.F. ABOVE FINISHED FLOOR THERMOSTAT E.C. ELECTRICAL CONTRACTOR e EQUIPMENT TAG EM INDICATES FIXTURE CONNECTED TO EMERGENCY SERVICE -GAS GAS PIPING F.B.O. FURNISHED BY OTHERS GAS COCK F & I FURNISHED AND INSTALLED D�4 REDUCER GFI GROUND FAULT INTERRUPTER • ELECTRICAL DEMOLITION NOTES . GRD GROUND INDICATES GREEN GROUND CONDUCTOR CONNECTED TO EQUIPMENT AND PANEL NL NIGHT LIGHT, 24 HOUR OPERATION 1. ELECTRICAL CONTRACTOR SHALL REVIEW THE ARCHITECTURAL DRAWINGS TO VERIFY THE EXTENT OF THE DEMOLITION AND REMODELING WORK. ELECTRICAL CONTRACTOR SHALL SURVEY EXISTING SITE AND DETERMINE EXTENT OF NECESSARY REALLOCATIONS. REMOVALS AND REPAIRS TO EXISTING ELECTRICAL WORK REQUIRED TO AVOID CONFLICTS WITH NEW CONSTRUCTION TO MEET MINIMUM LOCAL AND STATE CODE REQUIREMENTS. ALL ELECTRICAL OUTLETS, FIXTURES RECEPTACLES, DEVICES, ETC. NOT BEING REUSED SHALL BE REMOVED AND OUTLETS ARE TO BE CAPPED ACCORDING TO NOTE #7: CONDUIT TO BE ABANDONED IN PLACE: AND ALL WIRING SHALL BE DISCONNECTED AT SOURCE AND REMOVED COMPLETELY. NO EXISTING JUNCTIONS OR CONDUIT COVERS SHALL BE BURIED IN NEW WALLS. ELECTRICAL CONTRACTOR TO RELOCATE SAME AS. REQUIRED. A FIELD SURVEY VERIFICATION IS MANDATORY IN ORDER TO SUBMIT AN ELECTRICAL BID, FAILURE TO DO SO SHALL . NOT RELIEVE THIS CONTRACTOR FROM PERFORMING THE WORK OF THIS CONTRACT. 2. EXISTING CONDUIT CAN BE REUSED. PROVIDING IT IS CHECKED FOR CONTINUITY OF GROUND, BLOWN FREE OF DEBRIS, AND DOES NOT INTERFERE WITH NEW CONSTRUCTION. 3. ALL CUTTING AND PATCHING OF EXISTING PLASTER, DRYWALL, WOOD, CONCRETE ETC., FOR THE ELECTRICAL INSTALLATION IS BY THE ELECTRICAL CONTRACTOR. BEFORE ANY CUTTING, APPROVAL FROM THE ARCHITECT IS NECESSARY. CARE IS TO BE TAKEN AND ALL CUTS OR CORING ARE TO BE SQUARE - NO CHOPPING! 4. ALL EXISTING EQUIPMENT IS TO REMAIN OPERATIONAL DURING THE CONSTRUCTION PERIOD. ANY TEMPORARY WIRING OR REROUTING OF CIRCUITRY TO ACHIEVE THIS IS BY THE ELECTRICAL CONTRACTOR, SHUTDOWN OF EXISTING SERVICES SHALL ONLY BE PERMITTED UPON WRITTEN APPROVAL FROM THE OWNER AND THEN ONLY FOR THE DATE AND DURATION AGREED UPON. INCLUDE ALL PREMIUM TIME CHARGES IN THE BASE BID. 5. UNLESS INDICATED OTHERWISE, ALL LIGHTING FIXTURES, ELECTRICAL DEVICES AND ALL ITEMS OF THE EXISTING HVAC SYSTEM SHALL REMAIN UNLESS IN CONFLICT WITH REMODELING. 6. ALL LIGHTING FIXTURES REMOVED AND NOT REUSED SHALL BECOME THE PROPERTY OF THE OWNER. IF THE OWNER ELECTS NOT TO RETAIN FIXTURES, ELECTRICAL CONTRACTOR SHALL REMOVE FIXTURES FROM JOB SITE AND DISPOSE OF PROPERLY. 7. ELECTRICAL CONTRACTOR SHALL BLANK WITH PROPER FINISH PLATE IF FLUSH OUTLET EXISTS FOR ITEMS TO BE REMOVED. ANY INTERRUPTION OF CIRCUITING TO AREAS NOT BEING REMODELED SHALL BE INTERCEPTED AT A LOCATION THAT DOES NOT INTERFERE WITH NEW CONSTRUCTION. HOMERUN CIRCUITING FOR THESE INTERRUPTED CIRCUITS IS TO BE NEW WIRING. AFTER REMOVAL, ALL CONTINUITY IS TO BE CHECKED FOR ALL OUTLETS IN THE AREAS NOT BEING REMODELED TO. INSURE PROPER FUNCTIONING. 8. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH GENERAL CONTRACTOR FOR REMOVAL OR RELOCATION OF EXISTING ELECTRICAL EQUIPMENT (FOR EXAMPLE: LIGHTING FIXTURES, RECEPTACLES, DEVICES, CONDUIT AND WIRING) THAT WILL BE ABANDONED OR IN CONFLICT WITH NEW CONSTRUCTION. NO ADDITIONAL COST WILL BE PERMITTED. REFER TO ARCHITECTURAL DRAWINGS FOR EXTENT OF REMODELING. 9. ALL CONDUIT, DEVICES, FIXTURES, ETC. SHOWN IN THE DEMOLITION DRAWINGS TO BE REMOVED OR RELOCATED ARE ONLY FOR THE CONVENIENCE OF. THE BIDDERS. ELECTRICAL CONTRACTOR SHALL FIELD VERIFY ALL ITEMS PRIOR TO SUBMITTING A BID. 10. NEW WORK AND EQUIPMENT IN THE EXISTING BUILDING HAS BEEN INDICATED ON THE DRAWINGS AS ACCURATELY. AS POSSIBLE. EACH CONTRACTOR SHALL ADJUST HIS WORK AS REQUIRED TO AVOID EXISTING DUCTS, PIPES, CONDUITS AND BEAM NOT SHOWN ON PLANS. • EACH CONTRACTOR SHALL ADAPT HIS WORK TO MEET ALL ACTUAL CONDITIONS ON. THE EXISTING PREMISES. WP WEATHERPROOF SINGLE POLE TOGGLE SWITCH, 20 AMPERE RATED, MOUNTED 48" A.F.F. UNLESS NOTED OTHERWISE. SUBSCRIPT: "a" - LOWER CASE LETTER INDICATES SWITCH S CONTROL "3" - DENOTES THREE WAY TOGGLE SWITCH "2P" - DENOTES TWO POLE TOGGLE SWITCH "P" - DENOTES LIGHTED HANDLE TOGGLE SWITCH, LIGHT IN SWITCH SHALL LIGHT WHEN EQUIPMENT IS OPERATING "4" - DENOTES FOUR WAY TOGGLE SWITCH T ZED R TOGGLE HEATERELLEMENTS, 48" A.F.F. PROPERLY F.F. UNLESS EQUIPMENT MOUNTED ,.....-74....,.. CONDUIT RUN ROUTED CONCEALED IN WALLS OR ABOVE CEILING IN FINISHED AREAS. CONDUIT EXPOSED IN UNFINISHED AREAS �� CONDUIT RUN ROUTED CONCEALED IN BELOW CONCRETE SLAB / OR BELOW GRADE. r INDICATES "GREEN" GROUND CONDUCTOR, SIZED AS NOTED ON DRAWINGS p�. DUPLEX RECEPTACLE, 120 VOLT, 20 AMPERE RATED, 18" A.F.F. UNLESS NOTED OTHERWISE. HUBBELL OR LEVITON #5362-I, MTD # HORIZONTALLY IN JUNCTION BOX. SUBSCRIPT: "GFI" - DENOTES GROUND FAULT INTERRUPTER TYPE RECEPTACLE DIG" - DENOTES ISOLATED GROUND TYPE RECEPTACLE HUBBELL OR LEVITON #IG -5362 O DOUBLE DUPLEX RECEPTACLE, 120V, 20 AMP RATED 18 ". A.F.F. UNLESS OTHERWISE NOTED. MOUNTED IN COMMON JUNCTION BOX. DUPLEX RECEPTACLE, 120V, 20 AMPERE RATED 6 ABOVE FINISHED COUNTER TOP MOUNTED HORIZONTALLY. AT .. LOCATIONS WHERE THERE IS NO COUNTER TOP, RECEPTACLE SHALL BE MOUNTED 40" A.F.F. SPECIAL PURPOSE RECEPTACLE, VOLTAGE, RATING AND MOUNTING AS NOTED ON PLANS ELECTRICAL SYMBOL NOTES: Jo JUNCTION BOX CEILING MOUNTED NOTE: JUNCTION BOX WALL MOUNTED 1. RECEPTACLES, SWITCHES, AND COVER PLATES IN DINING ROOM ARE TO MATCH THE SURROUNDING WALL FINISHES AND MOUNTED AS FOLLOWS: A. NO SUBSCRIPT INDICATED MOUNTED HORIZONTALLY B. "V" INDICATES MOUNTED VERTICALLY. 2. ALL RECEPTACLES AND SWITCHES IN PREP AREA AND RESTROOMS NEED TO BE WHITE. 3. ALL COVER PLATES IN THE PREP AREA AND RESTROOMS NEED TO BE STAINLESS STEEL. 4. ON ALL CONDUIT RUNS: A. ARROW INDICATE HOME RUN TO PANEL B. SLASHES INDICATE QUANTITY OF WIRES. 1. SHORT SLASHES INDICATE PHASE AND SWITCH LEGS. 2. LONG SLASHES INDICATE NEUTRAL CONDUCTORS.. 3. LONG SLASHES WITH DOT INDICATE GREEN GROUND CONDUCTORS. 5. DOTTED SYBOL ON PLAN INDICATES EXISTING FIXTURE, DEVICE OR EQUIPMENT. REFER TO DEMOLITION NOTES AND SYMBOLS FOR FIXTURE INFORMATION. O JUNCTION BOX WITH FLEXIBLE CONDUIT CONNECTION ' SINGLE GANG TELEPHONE OUTLET, 18" A.F.F., HORIZONTAL MOUNTED, STUB EMPTY CONDUIT 6" [" 6 INTO ACCESSIBLE CEILING SPACE UNLESS NOTED OTHERWISE MOTOR CONNECTION ELECTRICAL PANEL a FUSED DISCONNECT SWITCH, SIZE AND RATING AS NOTED ON DRAWINGS NON -FUSED DISCONNECT SWITCH, SIZE AND RATING AS NOTED ON DRAWING e MECHANICAL EQUIPMENT TAG -SEE MECHANICAL EQUIPMENT SCHEDULE a SINGLE GANG OUTLET, 18" AFF., HORIZONTAL MOUNTED, STUB [" EMPTY CONDUIT 6" INTO ACCESSIBLE CEILING SPACE FOR CRT CABLES. CABLES F.B.O. UNLESS NOTED OTHERWISE. HEVIEWED.FOR COMPLIANCE WITH NFPA 70 - NEC JUL 23 2011 City of Tukwila BUILDING DIVISION E.L11--06i 5-0 RECEIVED CITY OF TUKWILA JUL 1 U 1011 PERMIT CENTER Abossein Engineering, L.L.C•. MECHANICAL - ELECTRICAL CIVIL - LEED FIRE PROTECTION 2100 112TH AVE. NE BELLEVUE, WA 98004 PH: (425) 462-9441 FAX: (425) 462-9451 E -Mail: cselvice @abossein.com www.abossein.com ENEENERBEEMBEIMI y 0 N E4ok ''` wry+ WA. 0 01 NI%TA 'la' h H O: (Js o o Revisions ISSUE FOR 006/30/11 ISSUE FOR OLL REVIEW JJ REVIEW PERMIT/ 07/15/11 ARCHITECT I MY CERTIFY NAT THESE FLANS HAVE BEEN ME- NDED UNDER NY SU?ERVISIQI AND THAT 10 TIE BEST OF NY IDOVLEDGE, THE SAIi COMPLY HMI ALL RUES, REGULATIONS AND ORDINANCES OF TUKVILA. VA RELATING TO STRUCTURES AND BUILDINGS. Drawn By Checked By Scale 1/4 " =1' -0" Date 06/30/2011 Job No. 1 1 -2100 Sheet N P -2 (OF 2)