Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit EL11-0657 - WESTFIELD SOUTHCENTER MALL - PANDORA JEWELRY
PANDORA JEWELRY 516 SOUThCENTER MALL EL1 1 -0657 City oPi'ukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: / /www.TukwilaWA.gov Parcel No.: 9202470010 Address: 516 SOUTHCENTER MALL TUKW Project Name: PANDORA JEWELRY ELECTRICAL PERMIT Permit Number: EL11 -0657 Issue Date: 09/02/2011 Permit Expires On: 02/29/2012 Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA Contact Person: Name: STEPHEN WOOD Address: 1124 EASTLAKE AV EAST, STE 201 , SEATTLE WA Contractor: Name: EAGLE ELECTRIC OF AUBURN LLC Address: PO BOX 1422 , AUBURN WA Contractor License No: EAGLEEA911LC Phone: 206 957 -6400 X 205 Phone: 253 833 -9230 Expiration Date: 06/06/2013 DESCRIPTION OF WORK: EXISTING FEEDER UPSIZED FROM 90 AMP TO 100 .AMP. INSTALL LIGHTING AND LIGHTING CONTROLS, NEW RECEPTACLES FOR CASEWORK AND CONVENIENCE, NEW ELECTRICAL CONNECTIONS TO HVAC EQUIPMENT, AND NEW FA SYSTEM ADDED. Value of Electrical: NRES: $16,000.00 RES: $0.00 Fees Collected: Type of Fire Protection: SPRINKLERS /AFA National Electrical Code Edition: Electrical service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: ,kuu $459.63 2008 Date: Oq, �2I I hereby certify that I have read and x ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complie with, hether specified herein or not. The granting of this permit does not pre e to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the perf• - ance of work. I am authorized to sits and obtain this electrical permit. Signature: Print Name: Date: -fleto 1 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/10 EL1 1-0657 Printed: 09 -02 -2011 PERMIT CONDITIONS Permit No. EL11 -0657 * *ELECTRICAL ** 1: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 2: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 3: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 4: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 5: The issuance of art electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 6: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. doc: EL -4/10 EL11 -0657 Printed: 09 -02 -2011 00 X205 i CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto://www.TukwilaWA.00v [SITE LOCATION Electrical Permit No. M1 Project No. (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print** Site Address: � SOU TliC a �' Tenant Name: P p. P► DO INN Jew L. Property Owners Name: WES: aO sapiA Mailing Address1AM £ OIA .4 10 1� 1 M , King Co Assessor's Tax No.: 112-02.q100 ID Suite Number. 5 5 Floor: 1 New Tenant: Tfle- 9t-prpdv vviksta, Yes ❑..No 91 69 Zip ICONTACT PERSON — Who do we contact when your permit is ready to be Issued Name:SlatigN tl a 00 1� Day Telephone: Mailing Address: 1 1 144 ONTO - P"V citlYrr LE guile 01 i3 10� y�p�� City z;p E -Mail Address:Sla VI v WI) C�ir 1 �* Fax Number: � • 194 e 4 ELECTRICAL CONTRACTOR INFORMATION Company Name: T8 0 Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Slate Zip Valuation of Project (contractor's bid price): $ 6 1 ID / 000 /� Scope of Work (please provide detailed information): 'MST Lit P.i ratuft 90A 'T ‘00k. NEW 1..16 45 I-110 CoNTP -01-S, 11� W a c V i f t L op - c w u-13 c.:oN v5N 1 evx Nan/ etec caves e cm o Td H vac. E Si S $i 1 �,. S LOOUT. Will service be altered? X Yes ❑ No Siydding more than 50 amps? ❑ Yes Type of Use: P. f r L cTottt Type of work: ❑ New ❑ Addition ❑ Service Change XRemodel ❑ Tenant Improvement I( Low Voltage ❑ Generator Fire Alarm ❑ Telecommunication ❑ Temporary Service Pro . e ed b : Puget Sound Energy ❑ Seattle City Light HAAppticaiwnsFanns•Applications On Ltnc1010 App icanons'7 -2010 - Electrical Pennii Applicanondoe bh Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings (including an attached garage) ❑ Garages, pools, spas and outbuildings ❑ Low voltage systems (alarm, furnace thermostat) $152.85 581.90 ea 559.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration 581.90 (no added/altered circuits) ❑ Service change with added/altered circuits S81.90 number of added circuits $11.55 ea ❑ Circuits added/altered without service change 554.60 (up to 5 circuits) ❑ Circuits added/altered without service change 554.60 (6 or more circuits) 57.65 ea ❑ Meter /mast repair 568.25 ❑ Low voltage systems 559.85 (alarm, furnace thermostat) MULTI - FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) 563.00 ❑ Temporary service (generator) $78.75 ❑ Manufactured/mobile home service 584.00 (excluding garage or outbuilding) ❑ Carnivals S78.75 Number of concessions 510.50 ea PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED F RIZZED �E tTO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR/ ELeC11 1 ti ENbitV- Signature: Liskiatied- Azie.uss Print Name: ROW S 1LON Mailing Address: fZ.5 Wt r W th-r & Date Application Accepted: m174 LI Date: —4• .21911 w�D�aynTelle Xt r ephone: Si` •• LH 2. • 110 UP Cily Stalc Zip Date Application Expires: JI 2 ' n Staff Initials: 1 11 PPIi i -Appl caner On Line 20I0 Apphcatiam`7•2010 • Electrical Penns AppliwioKdoc bh Page 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -43 1 -3670 Fax: 206-431-3665 Web site: http: / /www.TukwilaWA.gov Parcel No.: 9202470010 Address: Suite No: Applicant: PANDORA JEWELRY 516 SOUTHCENTER MALL TUKW RECEIPT Permit Number: Status: Applied Date: Issue Date: EL11 -0657 ISSUED 07/20/2011 09/02/2011 Receipt No.: R11 -02123 Initials: WER User ID: 1655 Payee: Payment Amount: Payment Date: Balance: $63.00 09/28/2011 10:42 AM $0.00 SHRADER & MARTINEZ CONSTRUCTION INC TRANSACTION LIST: Type Method Descriptio Amount Payment Check Authorization No. ACCOUNT ITEM LIST: Description 32214 63.00 Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.00 Total: $63.00 63.00 doc: Receipt -06 Printed: 09 -28 -2011 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: / /www.TukwilaWA.gov RECEIPT Parcel No.: 9202470010 Permit Number: EL11 -0657 Address: 516 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 07/20/2011 Applicant: PANDORA JEWELRY Issue Date: Receipt No.: R11 -01808 Initials: LAW User ID: 1632 Payment Amount: $367.70 Payment Date: 08/19/2011 10:01 AM Balance: $0.00 Payee: SHRADER & MARTINEZ CONSTRUCTION INC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 31610 367.70 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.00 367.70 Total: $367.70 doc: Receiot -06 Printed: 08 -19 -2011 CAP of Tukwila. so Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: /Avww. ci. tukw ila. wa. us SET RECEIPT RECEIPT NO: R11 -01527 Initials: JEM Payment Date: 07/20/2011 User ID: 1165 Total Payment: 3,084.45 Payee: BEN BRIDGE SET ID: S000001532 SET NAME: Tmp set/Initialized Activities SET TRANSACTIONS: Set Member Amount D11 -240 2,885.20 EL11 -0657 91.93 M11 -104 66.11 PG11 -109 41.21 TOTAL: 2,885.20 TRANSACTION LIST: Type Method Description Amount Payment Check 334464 3,084.45 TOTAL: 3,084.45 ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - NONRES ELECTRICAL PLAN - NONRES PLAN CHECK - NONRES 000.322.100 000.345.832.00.0 000.345.830 TOTAL: 1,660.34 91.93 1,332.18 3,084.45 INSPECTION RECORD !f i �- �b5 Retain a copy with permit t.L INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Fp (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: ��� Type of Inspection: 2. too Address: 51 19 � Date Called: Special Instructions: • Date Wanted:. m: Requester: Phone No: Approved per applicable codes. a Corrections required prior to approval. COMMENTS: kficifickls nor* 'Inspector: (Date: ��1 „n�30 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD ri r O .x/57 Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TU.KWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 tit (206) 431 -367 Permit Ins ection Request Line (206) 431. -2451 AD OZA fail/620 Address: s/e Special Instructions Project: T pe of Inspection: ;/00 Date Called: Date Wanted: Requester: 9/4 Phone No: EJApproved per applicable codes. Corrections required prior to approval. . COMMENTS: Q • , / Ol.t =.�l et KTO N ii0)%tfrx6 SSE • S i f ‘©N cd i® giSk (c .il c -- Kpower K . To gE tisrs> imewn.vics Os%Scam, • 17-C MM? NW) O 1 tf REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. W r ■ 3 INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF' TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 f_ (206) 431 -36 Permit Inspection Request Line (206) 431 -2451 Project: I)PA h J kk V Type of Inspection: 700 , Address: Date Called: Special Instructions: Date Wanted:. 9l r� a.m p.m. Requester: I Phone No: Approved per applicable codes. 1 Corrections required prior to approval. COMMENTS: 0-K Ultd- Inspector: Date: toty 1 LI REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD eu Retain a copy with permit r- 57 INSPECTION NO. PERMIT NO. CITY OF' TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3 Permit Inspection Request Line (206) 431 -2451 Project: 3rr'1hO(kk Type of Inspection: 7 00, Address: / Sti9 t1k Date Called: ,Special Instructions: Date Wanted:. 'Requester: � �3 ' a. ` Phone No: JApproved per applicable codes. El Corrections required prior to approval. COMMENTS: AtTf�► ,. r tia,9Lip �• 14 !Inspector: Date: 093 / rei REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. - i INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION '! 6300 Southcenter Blvd., #100, Tukwila. WA 98188 R (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: AADO ikfk Type of Inspection:, 740/ Address: 540 11444./ Date Called: Special Instructions: Date Wanted:. P Requester: Phone No: • Approved per applicable codes. D Corrections required prior to approval. OMMENTS: o.� f l0d CAJNti-5 Inspector: 17 'Date: 01/0411 i ri REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. HERMIT COORD CAFE PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL11 -0657 DATE: 09/19/11 PROJECT NAME: PANDORA JEWELRY SITE ADDRESS: 516 SOUTHCENTER MALL Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # X Revision # 1 after Permit Issued DEPARTMENTS: 0146-t■ Building ivision Public Works • Fire Prevention Structural Planning Division ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete cXI Incomplete DUE DATE: 09/20/11 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route lAl Structural Review Required No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 10 /18 /11 Approved ❑ Approved with Conditions N- Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit'Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 IIPERMIT COORD COOP PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL11 -0657 DATE: 07/20/11 PROJECT NAME: PANDORA JEWELRY SITE ADDRESS: 516 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMENrTS:^ Buuilaing Division Public Works i❑ Fire Prevention Structural Planning Division Permit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete DUE DATE: 07/21/11 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required n No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 08 /18 /11 Approved Approved with Conditions Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit•Center Use Only • CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 PROJECT NAME: PA 140 v - PERMIT NO: • E' SITE ADDRESS: 51,Q C,C M PrLt- ORIGINAL ISSUE DATE: REVISION LOG REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS 1 OPI ICit i nV,?-9// r Aw Summary of Revision: (oip� 01 @ tie coll--trX Etett P t, m--- Received by: 5 il; ge9 f ) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Web site: http: //www.ci.tukwila.wa.us REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: it J ct - 2° ( Plan Check/Permit Number: e (-- 11 — 01:N7 ❑ Response to Incomplete Letter # Response to Correction Letter # Revision # ( after Permit is Issued Revision requested by a City Building Inspector or Plans Examiner Project Name: TAN) 002 J Eu0 L % S-ro R E Project Address: StAp Sod- r K G t= N TiE 2 u t' '∎ LL .4 Contact Person: 5 7 E t( E rJ W'0 P Phone Number: Summary of Revision: "- . -CH F ro o r-t (o Z t' AC_ F- o o (`t l ° I 1 L k p 9 -To M A K E S�c�J €a-(-- it . cc) N) E� 11 — uP GLA&0E c-LE-L- r(LicAL FRSEL 'FEE.° uECAcU -RO To 4(i-r& AP PE D TO t /} C Ct U N 1-Z5-Pr W ST l LrA So° T 1 C Arks; -2.e) C, R 7- Cy-tmxzc ,.,TALC:, Oc jbk„14f,L A 1 91011 ' -EgMtT t*F Sheet Number(s): 0 0 / t. t. 01 // E 2.0Z- "Cloud" (G or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: 0( Entered in Permits Plus on H:\ApplicationsTorms- Applications On Line \2010 Applications N7-2010 - Revision Submithl.doc Crated: 8-13 -2004 Revised: 7 -2010 Contractors or Tradespeople Pjer Friendly Page • Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company EAGLE ELECTRIC OF AUBURN LLC 2538339230 Po Box 1422 Auburn WA 98071 King Limited Liability Company UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 602921724 Active EAGLEEA911LC Electrical Contractor 6/3/2009 6/6/2013 General Unused Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status EAGLEEC140P6 EAGLE ELECTRIC CO Electrical Contractor General Unused 10/2/1986 10/2/2002 Archived EAGLEEC161PDEAGLE ELECTRIC CO Electrical Contractor Residential Unused 10/4/1984 12/31/1986 Archived EAGLEEL991BU EAGLE ELECTRIC LLC Electrical Contractor General Unused 1/31/2001 1/31/2011 Expired Electrical Administrator INFORMATION License FISCHJT921P9 Name FISCHER, JEFFREY T Status Active Business Owner Information Name Role Effective Date Expiration Date FISCHER, JEFFREY T Agent 06/05/2009 5/11/2010 MCMANUS, BRIAN Partner /Member 06/03/2009 $250.00 FISCHER, JEFFREY T Partner /Member 06/03/2009 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 RLI INS CO LSM0095335 06/02/2009 Until Cancelled $4,000.00 06/03/2009 Assignment of Savings Information No records found for the previous 6 year period Insurance Information No records found for the previous 6 year period Summons /Complaint Information Summons and Complaints are not filed with the department for this contractor type Warrant Information Warrants are not filed with the department for this contractor type Infractions /Citations Information Infraction / Citation Date RCW Code Type Status Violation Amount EBEAK00277 5/11/2010 19.28.101 RCW ELECTRICAL CITATION Satisfied $250.00 https://fortress.wa.gov/lni/bbip/Print.aspx 09/02/2011 e SCHEDULE NOTES 1. Conduit sizing based on Rigid Galvanized Steel Conduit, Type THW wire taking into account both conduit fill & Jamb ratio. 2. Ampacities (NEC Table 310 -16) are based on the following: a. 75° Rating for wire sizes upto & including AWG #1. b. 90° rating for 5W feeders de -rated to 80% where predominantly harmonic currents are present. Neutrals > or = to 1/0 are paralleled on 5W feeders. 3. Increase raceway size for other types of raceways & difficult or long pulls. 4. Set of Phase, Neutral and Ground conductors are to be installed in each raceway noted. REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. Nt1 T 7: Fev signs will require a new plan submittal may include additional plan review fees. Project: Subject: Equip. No. COPPER FEEDER SCHEDULE, 34) XFMR 480D PANELS XFMR 208Y/120V MAX LOAD AMPS SYSTEM TAG NO" OF RACEWAYS RACEWAY SIZE PHASE CONDUCTORS NEUTRAL GROUND AMPSICOND AMPS CB BY cut # 30kVA 83.3A 104 4W 125.4 1 1-1/2" 3 #1 1 #1 1 #6 130 130 125 SCHEDULE NOTES 1. Conduit sizing based on Rigid Galvanized Steel Conduit, Type THW wire taking into account both conduit fill & Jamb ratio. 2. Ampacities (NEC Table 310 -16) are based on the following: a. 75° Rating for wire sizes upto & including AWG #1. b. 90° rating for 5W feeders de -rated to 80% where predominantly harmonic currents are present. Neutrals > or = to 1/0 are paralleled on 5W feeders. 3. Increase raceway size for other types of raceways & difficult or long pulls. 4. Set of Phase, Neutral and Ground conductors are to be installed in each raceway noted. REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. Nt1 T 7: Fev signs will require a new plan submittal may include additional plan review fees. Project: Subject: Equip. No. PANDORA WESTFIELD MEP COORDINATION SCHEDULE PANEL SCHEDULE PANEL: pi LOCATION: STARTER DISCONNECT General Comments Service /Description Location OC PROTECT FEEDER FED FROM: 1 LOAD CIRCDTFDESCRIPTION TYPE TYPE FURNISHED BY FURNISHED TYPE BY cut # 1 Quantity Voltage phase FRAME TRIP C WIRE MCA TOTAL KW 15 16 15 16 1 208V 3 PHASE SECTION A B C A B C A 2 I 20 0.75 MLSC REFRIGERATOR WEST CASEWORK REC 0.85 20 I 3 4 1 ' - • - : • • • ' ' 0 • MICROWAVE • : REC 1 20 ''� i 1 5 6 1 20 1,00 MISC STEAMER DUPLEX CASHWRAP (2) QUADS ACU-R-1 (HTR) ROOF TOP UNIT HEAT ROOF 1 208 3 30 25 3/4" 3 #10 &1 #10G 21 7.6 NA GENERAL (4) RECEPS IN RETAIL SPACE REC FUSED 20 X 9 1 : 1 PH' 5 1 10 1 20 _ MISC VIDEO EQUIP RECEP DEW-2 REC 4.16 50 2 11 12 1 20 DWH -1 WATER HEATER BATHROOM 1 208 1 30 30 3/4" 2 #10 &1 #10G 20 4.2 NA 30 2.18 FUSED ACU -R 1 X REC DWH -2 WATER HEATER BACK ROOM 1 208 1 60 50 2" 2 #3/0 & 1 #2G 40 8.3 NA - REC FUSED - X 17 120V 1 PHASE SECTION 18 - - 2.18 MISC - RETAIL LIGHTING LTG 1.11 20 1 19 A B C 20 1 EF -1 BATHROOM EXHAUST L1 1 120 1 20 15 1/2" 2 #12 & 1 #12G 1 0.08 X ' : ' 1 $ - : • N' Controlled by occupancy sensor 20 1 23 9A 3 25 251 MISC ACTT R 1 HEATER 20 I 1ST FLOOR MAIN ELECTRICAL ROOM ------------------ -- - - -- SECION f -SEC-ION 2 TSECION 3 TSECION 4 TSECION 5 TSECION 6 i SECION 7 1 SEC-1E44-8 1 1 1 1 1 . 1 1 1 1 1 1., 1 1 1 1 1 1 ' INCOMING' L SECT1ONI 1 1 1 1 i 1 (6) EXST ___ ____1____1_____1 ■ LMETEO J____ M _I_ . N M J MAIN DISTRIBUTION PANEL 2. 4. NEW PANDORA BACK OFFICE ----- -- ---1 I � 1 P1 LOAN. MOM MON IMO IEWA aw■Imm Mb MN WW1 I L 3000A,208Y/120V, 65kAIC SEPARATE PERMIT REQUIRED FOR: 'Methanicsi 0 Electrical L+I'Plumbing Ginn Piping City of Tukwila BIDING DIVISION !Ai FILE COPY Permit No. $ 7 Plan review approval is subject to errors and =helms. Approval of onln documents does not authorize th: v oiation of any adopted code or oniinance. Receipt el cpproved Field Copy and conditions is al mowledg d: B Date: City Of Tukwila BUILDING DIVISION SECTION 6 METER INFORMATION: 1. HDS SPACE #576, SUITE 1: 200A/3P 2. LA CHATEL SPACE #580, SUITE 504: 200A/3P 3. SPARE, 200A/3P 4. FRANCESCA'S COLLECTION, SUITE 611: 100A/3P 5. CHAROLETTE RUSSE, SUITE 621: 200A/3P 6. EXISTING M'S STORE (NEW PANDORA METER), SUITE 516: 100N3 REVIEWED FOR COMPLIANCE WITH NFPA70 -NEC s P 20 2011 FLAG NOTES: WORK BY LANDLORD AS DESCRIBED IN THE WESTFIELD MALL ENGINEERING CRITERIA MANUAL: PULL BACK BUSTING 90A FEEDER TO PANEL P1 IN PANDORA SPACE. PULL NEW 125A FEEDER THROUGH EXISTING 1 -1/2" CONDUIT. REMOVE EXISTING 90A MCB IN PANEL P1. PROVIDE NEW 125A MAIN CIRCUIT BREAKER IN PANEL P1. EC TO PROVIDE NEW CIRCUIT BREAKERS AS NECESSARY TO ACCOMODATE NEW EQUIPMENT IN PANDORA SPACE. REPLACE EXISTING 100A METER SOCKET SERVING THE PANDORA SPACE (IN POSITION 6 IN SECTION 6 IN MAIN ELECTRICAL ROOM) WITH THE EXISTING 200A SPARE METER POSITION (IN POSITION 3 IN SECTION 6). REPLACE EXISTING 200A METER SOCKET IN POSITION 6 WITH THE 100A METER SOCKET REMOVED. City of Tukwila, UILDING DIVISION S A G A rc h itects 1124 Eastlake Ave East Suite 201 Seattle, WA 98109 0 206 957 6400 Q 206 957 6404 RU WING Engineering - Essentials - Delivery 1725 WESTLAKE AVE N SUITE 300 SEATTLE, WA 98109 P: (206) 285 -7100 F: (206) 285 -7111 9.16.2017 PANDORA" WESTFIELD SOUTHCENTER 633 SOUTHCENTER STOREFRONT 588 SEATTLE, WA 98188 DATE DESCRIPTION 09 -06-11 CCD -1 09 -16-11 PERMIT REV ELECTRICAL RISER & MEP COORDINATION SCHEDULE EL1 1-O61 RECEIVED_ LA SEP 19 2011 PERMIT CENTER SCALE: DRAWN: CHECKED: PROJECT NO: 10008.03 E0.01 R PANEL SCHEDULE PANEL: pi LOCATION: PANDORA BOH VOLTS: 208 Y/ 120 P 3 MC RATING: 65,000 NEUTRAL: 100% W: 4 MLOD MCB X MOUNT: X SURFACE FLUSH TYPE: EXISTING X NEW STYLE: FED FROM: 1 LOAD CIRCDTFDESCRIPTION TYPE WAD KVA OCT BKR P cut # 1 P H OR it P CKT BKR LOAD KVA LOAD TYPE CIRCUITDBBCRIPTION EAST CASEWORK REC 0.84 20 1 1 A B C A B C A 2 I 20 0.75 MLSC REFRIGERATOR WEST CASEWORK REC 0.85 20 I 3 4 1 20 0.50 MLse MICROWAVE CENTER CASEWORL & FRONT CASEWORK REC 033 20 1 5 6 1 20 1,00 MISC STEAMER DUPLEX CASHWRAP (2) QUADS REC 0.72 20 I 7 8 1 20 1.08 REC BOH GENERAL (6) RECEPS GENERAL (4) RECEPS IN RETAIL SPACE REC 0.72 20 I 9 10 1 20 1.00 MISC VIDEO EQUIP RECEP DEW-2 REC 4.16 50 2 11 12 1 20 0.72 REC BOH (2) QUADS - REC 4.16 - - 13 14 3 30 2.18 MISC ACU -R 1 DHW -1 REC 2.08 30 2 15 11 C 16 - - 2.18 MISC - - REC 2.08 - - 17 18 - - 2.18 MISC - RETAIL LIGHTING LTG 1.11 20 1 19 A B C 20 1 20 0.08 MTR EXHAUST FAN RETAIL LIGHTING LTG 1.23 20 1 21 ' : ' 1 $ - : • N' 20 1 23 9A 3 25 251 MISC ACTT R 1 HEATER 20 I 25 A 26 - - 2.51 MISC - 20 1 27 B C A B C 28 30 - - 251 MISC - 20 I 29 20 1 31 32 1 20 20 1 33 34 I 20 20 1 35 36 I 20 20 1 37 A B C 38 1 20 20 1 39 40 I 20 20 1 41 42 1 20 ESTIMATED MAXIIIUM DEMAND (EMD) CALCULATIONS WAD SUMMARY: WAD TYPE: CONNECTED NEC DEMAND 1 CONNECTED PHASE LOADING LIGHTING LTG 234 KVA RESIDENT LTG/RECPT RES 0.00 KVA SMALL APPLIANCE RES 0.00 KVA LARGEST MOTOR 0.00 KVA REMAININGMOTOIS MTR 0.08 KVA GEN PURPOSE RECPT REC 18.13 KVA COMPUTER REC1 F MISC 0.00 KVA EQUIP/OTHER MISC 9.79 KVA HEATING MISC 7.53 KVA ELEVATOR ELEV 0.00 KVA KITCHEN EQPT KITCH 0.00 KVA 2.93 KVA (125 %) 0.00 KVA ( 100/35/25 %) 0.00 KVA ( 100/35/25 %) 0.00 KVA (125 %) 0.08 KVA (100%) 14.06 KVA ( 50% > 10KVA) 0.00 KVA (100%) 9.79 KVA (100%) 7.53 KVA (100%) 0.00 1CVA ® 100% 0.00 KVA ® 65% 34.39 KVA 95.45 AMPS AT INDICATED DEMAND AT 100% PHASE A: 13.43 KVA PHASE B: 11.25 KVA PHASE C: 13.18 KVA NOTES: 1 NOTES TOTALS 37.87 KVA 105.11 AMPS LOAD TYPE NOTES: "COMB" = COMBINATION LOAD TYPES ON INDICATED CIRCUIT "RES "= RESIDENTIAL LTG/RECPT OR SMALL APPLIANCE LOAD TAKEN "MISC" = EQUIP, COMPUTER REC OR HTG LOAD ON INDICATED CIRCUIT SECION f -SEC-ION 2 TSECION 3 TSECION 4 TSECION 5 TSECION 6 i SECION 7 1 SEC-1E44-8 1 1 1 1 1 . 1 1 1 1 1 1., 1 1 1 1 1 1 ' INCOMING' L SECT1ONI 1 1 1 1 i 1 (6) EXST ___ ____1____1_____1 ■ LMETEO J____ M _I_ . N M J MAIN DISTRIBUTION PANEL 2. 4. NEW PANDORA BACK OFFICE ----- -- ---1 I � 1 P1 LOAN. MOM MON IMO IEWA aw■Imm Mb MN WW1 I L 3000A,208Y/120V, 65kAIC SEPARATE PERMIT REQUIRED FOR: 'Methanicsi 0 Electrical L+I'Plumbing Ginn Piping City of Tukwila BIDING DIVISION !Ai FILE COPY Permit No. $ 7 Plan review approval is subject to errors and =helms. Approval of onln documents does not authorize th: v oiation of any adopted code or oniinance. Receipt el cpproved Field Copy and conditions is al mowledg d: B Date: City Of Tukwila BUILDING DIVISION SECTION 6 METER INFORMATION: 1. HDS SPACE #576, SUITE 1: 200A/3P 2. LA CHATEL SPACE #580, SUITE 504: 200A/3P 3. SPARE, 200A/3P 4. FRANCESCA'S COLLECTION, SUITE 611: 100A/3P 5. CHAROLETTE RUSSE, SUITE 621: 200A/3P 6. EXISTING M'S STORE (NEW PANDORA METER), SUITE 516: 100N3 REVIEWED FOR COMPLIANCE WITH NFPA70 -NEC s P 20 2011 FLAG NOTES: WORK BY LANDLORD AS DESCRIBED IN THE WESTFIELD MALL ENGINEERING CRITERIA MANUAL: PULL BACK BUSTING 90A FEEDER TO PANEL P1 IN PANDORA SPACE. PULL NEW 125A FEEDER THROUGH EXISTING 1 -1/2" CONDUIT. REMOVE EXISTING 90A MCB IN PANEL P1. PROVIDE NEW 125A MAIN CIRCUIT BREAKER IN PANEL P1. EC TO PROVIDE NEW CIRCUIT BREAKERS AS NECESSARY TO ACCOMODATE NEW EQUIPMENT IN PANDORA SPACE. REPLACE EXISTING 100A METER SOCKET SERVING THE PANDORA SPACE (IN POSITION 6 IN SECTION 6 IN MAIN ELECTRICAL ROOM) WITH THE EXISTING 200A SPARE METER POSITION (IN POSITION 3 IN SECTION 6). REPLACE EXISTING 200A METER SOCKET IN POSITION 6 WITH THE 100A METER SOCKET REMOVED. City of Tukwila, UILDING DIVISION S A G A rc h itects 1124 Eastlake Ave East Suite 201 Seattle, WA 98109 0 206 957 6400 Q 206 957 6404 RU WING Engineering - Essentials - Delivery 1725 WESTLAKE AVE N SUITE 300 SEATTLE, WA 98109 P: (206) 285 -7100 F: (206) 285 -7111 9.16.2017 PANDORA" WESTFIELD SOUTHCENTER 633 SOUTHCENTER STOREFRONT 588 SEATTLE, WA 98188 DATE DESCRIPTION 09 -06-11 CCD -1 09 -16-11 PERMIT REV ELECTRICAL RISER & MEP COORDINATION SCHEDULE EL1 1-O61 RECEIVED_ LA SEP 19 2011 PERMIT CENTER SCALE: DRAWN: CHECKED: PROJECT NO: 10008.03 E0.01 R CASEWORK SCHEDULE Tag Casework Name Quantity Connection Type AFF WIUnit Comments C1 UD.1 Receptacle - 72W Located next to a SEK.2 or 3, plugs directly into SEK.2 or 3. C2 SP.1 Receptacle 18" 36W Cord provided with casweork assembly. Plugs into standard duplex. C3 SEK.2 Hardwired 18" 54W Casework hardwired to junction box recessed in wall. C4 SEK.3 Hardwired 18" 81W Casework hardwired to junction box recessed in wall. C5 PL.1 Receptacle 50" 24W TV unit plugs directly into receptacle. C6 GL.1 Floorbox - 30W Cord provided with casweork assembly. Plugs into duplex located in a floorbox, or daisy chain to adjacent equipment. C7 G1.2 Floorbox - 30W Cord provided with casweork assembly. Plugs into duplex located in a floorbox, or daisy chain to adjacent equipment. C8 GL.3 Floorbox - 30W Cord provided with casweork assembly. Plugs into duplex located in a floorbox, or daisy chain to adjacent equipment. C9 GL.5 Floorbox - 30W Cord provided with casweork assembly. Plugs into duplex located in a floorbox, or daisy chain to adjacent equipment. C10 HJ.4 Floorbox - 24W Cord provided with casweork assembly. Plugs into duplex located in a floorbox, or daisy chain to adjacent equipment. C11 WIN.3A Floorbox - 12W Casework located in front window. Provide a floor mounted NEMA L5 -20R receptacle located below the left leg from the customer side. C12 WIN.3B Receptacle 36" 12W Casework located adjacent to a wall. Provide a flush mounted NEMA 15 -20R located at 36" AFF C13 JT.2 Floorbox - 54W Cord provided with casweork assembly. Plugs into duplex located in a floorbox. Cord comes from underneath the right leg from the customer side ELECTRICAL FLOOR PLAN - POWER & LOW VOLTAGE E-E SCALE: 1/4" = r-m GENERAL NOTES: 1. ALL CASEWORK RECEPTACLES THAT CONTAIN LIGHTING TO BE ON A RELAY TO SHUT OFF DURING UNOCCUPIED HOURS. OVERRIDE SWITCH TO BE PROVIDED IN BACK OFFICE. REFER TO SHEET E2.02 FOR RELAY SCHEDULE. 2. CCTV CAMERAS TO BE PROVIDED BY AND INSTALLED BY CAMERA VENDOR, AND ARE POWERED BY VIDEO EQUIPMENT IN BACK. VENDOR TO PROVIDE CABLING TO EQUIPMENT. SHOWN ON PLANS FOR LOCATION ONLY. 3. ELECTRICIAN TO PULL CATSE TO ALL TELECOM LOCATIONS FROM THE EXISTING TELECOM BACKBOARD. TERMINATIONS WILL BE DONE BY THE PHONE INSTALLER. 4. ALL FIRE ALARM DEVICES TO BE TIED IN TO BUSTING BUILDING FA SYSTEM. 5. REFER TO MEP COORDINATION SCHEDULE ON SHEET E0.1 FOR WIRING REQUIREMENTS TO MECHANICAL EQUIPMENT. 6. REFER TO ARCHITECTURAL DRAWINGS FOR DEVICE LOCATIONS AND ELEVATIONS. 7. PROVIDE CONDUIT AND WIRE FOR CIRCUITING SHOWN. 1 /2 "C, #12AWG OR MC CABLE AS PERMITTED BY LANDLORD. FLAG NOTES: SAW CUT SLAB FOR CONDUIT AND WIRING ROUTING TO FLOOR BOX LOCATION. CONFIRM FLOOR BOX LOCATION WITH CASEWORK PRIOR TO TRENCHING. SAW CUT SLAB AND PROVIDE 3/4 "C TO SERVE TELECOM CABLING TO TELECOM OUTLETS LOCATED ON FLOATING CASEWORK. CONFIRM TELECOM ROUTE PRIOR TO PERFORMING ANY WORK. CONFIRM LOCATION OF OUTLETS WITH ARCHITECT PRIOR TO ROUGH PROVIDE WATTSTOPPER LP12 OR EQUIVALENT RELAY PANEL. PROVIDE TELEPHONE BACK BOARD FOR PHONE SYSTEM IF REQUIRED. CONFIRM REQUIREMENTS WITH PANDORA AND TELECOM PROVIDER PRIOR TO INSTALLATION. PROVIDE SURFACE MOUNTED DUPLEX RECEPTACLES FOR CASH REGISTER AND COMPUTER LOCATED ON CASEWORK. FELD VERIFY LOCATION OF RECEPTACLES IN CASEWORK AND CONFIRM WITH ARCHITECT PRIOR TO ROUGH -IN. SAW CUT SLAB FOR (2) 3/4" CONDUITS TO CASEWORK RECEPTACLES. EXISTING 208Y/120V, 90A, 65kAIC PANEL "P1" TO BE RELOCATED TO EXISTING LOCATION SHOWN BY OWNER AND RE -USED FOR THE NEW PANDORA SPACE. PANEL TO BE UPSIZED. REFER TO RISER FOR ADDITIONAL DETAILS. EXHAUST FAN TO BE CONTROLLED BY OCCUPANCY SENSOR SWITCH. SEE E2.02. CASEWORK DAISY CHAINED TOGETHER AND PLUGGED INTO FLOOR BOX. PLUG AND CORD PROVIDED WITH CASEWORK. REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC nP 2 u 2011 City of Tukwila BUILDING DIVISION SA B A rc h itects 1124 Eastlake Ave East Suite 201 Seattle, WA 98109 0 206 957 6400 0 206 957 6404 RUS�fING Engineering-Essentials-Delivery 1725 WESTLAKE AVE N SUITE 300 SEATTLE, WA 98109 P: (206) 285 -7100 F: (206) 285 -7111 9.16.2011 PANDORA` WESTFIELD SOUTHCENTER 633 SOUTHCENTER STOREFRONT 588 SEATTLE, WA 98188 DATE DESCRIPTION 09 -06-11 CCD -1 09 -16-11 PERMIT REV ELECTRICAL FLOOR PLAN - POWER & LOW VOLTAG E REVISION N0:1 SCALE: DRAWN: CHECKED: PROJECT NO: ELi d (Os 7 CITY OF i�UKNALA SEP 19 2011 PERMIT CENTER 10008.03 E2.01 E ISTIC REDREW! PANEL —LOWED e PLj: 'WOOD SL HON- PANLL PANEL AL WINK _ JP LIGHTING FIXTURE SCHEDULE Tag # Lamps Lamp Type Wattage. Mfger Fixture Cat. No. Fixture Description p 1 T10 HALOGEN 150 FLOS ZEPPELIN S1- FU9$0009 Dimmable Decorative chandelier for focal areas. Dimensions: 43.3" X 29 "H. Confirm mounting height with architect. N1 1 LED 30 Amerlux C3R -1 -26- LED -E -WT- 120- FL -WT- 3000 -DIM Dimmable White LED retail accent light with electronic constant current LED driver and (1) head. Confirm beam spread with architect. N2 2 LED 60 Amerlux C3R -2 -26- LED -E -WT- 120- FL- FL -WT- 3000 -DIM Dimmable White LED retail accent Tight with electronic constant current LED driver and (2) heads. Confirm beam spread with architect. w 2 LED 60 Amerlux C3R -2 -26- LED -E -WT- 120- WF- WF -WT- 3000 -DIM Dimmable White LED retail accent Tight for main pathways with electronic constant current LED driver and (2) heads. Confirm beam spread with architect. W3 1 LED 68 Amerlux CAV- II -64- LED -E -WT- 120 -WF -3000 Recessed adjustable graphic LED wall washer for back wall. High performance aluminum heat sink with white powder coat paint. Confirm beam spread with architect. B 2 CFL 64 Metalux 2GR8- 232- A- UNV -EB8 Recessed 2x4 Fluorescent with (2) T8 lamps for back of house space. T - - - Amerlux GES204 -3 Track for window lights. Confirm track length with architect. T1 1 LED 35 Amerlux C3TV 30- LED- E- WT -TN1- 120 -FL -3000 -DIM Dimmable White LED track heads along window display. Confirm beam spread with architect. EX 1 LED 0.71 _ Lithonia LQM- S- W -EL -N Termoplastic LED exit sign with emergency operation. Provide white with green lettering. EXE 1 LED 3.7 Juno NXESBA- 1 -G -WH Surface mount edge -lit exit sign with battery back -up and green letters and white finish. EM 2 5.4W, 6V lamps 10.8 Lithonia ELM Back of house emergency lighting unit. White thermoplastic quick mount unit with lead- calcium battery. EM1 2 20W LED 45 Sure -Lites CEL- 4020 -70 -120 Sales floor concealed emergency lighting with sealed lead calcium battery with 120 minutes of run time. ELECTRICAL FLOOR PLAN - LIGHTING GENERAL NOTES: 1. PROVIDE UNSWITCHED CIRCUIT TO EXIT SIGNS AND EMERGENCY LIGHTING UNITS. 2. ALL UGHTING IN RETAIL -SPACE TO BE ON A RELAY TO SHUT OFF ALL UGHTING DURING UNOCCUPIED HOURS. OVERRIDE SWITCH TO BE LOCATED IN BACK ROOM. REFER TO RELAY SCHEDULE FOR RELAY ZONES. 3. CIRCUIT ALL LIGHTING TO PANEL Pl. REFER TO PLAN FOR CIRCUIT NUMBERS /LINE VOLTAGE SWITCH LEGS. 4. PROVIDE CONDUIT AND WIRE FOR CIRCUITING SHOWN. 1/2 "C, #12AWG OR MC CABLE AS PERMITTED BY LANDLORD. FLAG NOTES: PROVIDE ELECTRICAL CONNECTION TO SIGNAGE LIGHTING. CIRCUIT TO PANEL P1/21 VIA RELAY 5. PROVIDE A DOUBLE GANG BOX WITH (5) LOW VOLTAGE OVERRIDE PUSH BUTTONS TO INTERFACE WITH RELAYS, WATTSTOPPER #RS OR EQUIVALENT. REFER TO LOW VOLTAGE SWITCH DETAIL ON SHEET E0.02. PROVIDE LABELS AS SHOWN IN DETAIL. REFER TO SWITCH BANKTAIL ON SHEET EO.02 FOR LINE VOLTAGE ITCH DETAILS. CONTRACTOR TO PROVIDE LABELS AS SHOWN IN DETAIL. LIGHTING CONTROL PANEL: LCP 1 208Y/120V RELAY LOCATION SERVED FIXTURE TYPE(S) CIRCUIT CONTROL ON OFF OVERRIDE 1 EAST CASEWORK - P1/1 TC TC S 2 WEST CASEWORK - P1/3 TC TC S 3 CENTRAL CASEWORK - P1/5 TC TC S 4 WINDOW CASEWORK - P1/5 TC TC S 5 STOREFRONT SIGNAGE - P1/21 TC TC S 6 WINDOW LIGHTING T1, N1 P1/21 TC TC S 7 STORE LIGHTING W, N1, W3 P1/19 TC TC S 8 STORE LIGHTING (CENTRAL) N1, N2, P P1/21 TC TC S 9 SPARE 10 SPARE 11 SPACE 12 SPACE ABBREVIATIONS: TC = TIMECLOCK (ASTRONOMICAL) S = LOW VOLTAGE SWITCH PC = PHOTO CELL PS = PHOTO SENSOR OS = OCCUPANCY SENSOR REVIEWED _F COMPLIANCE SCALE: 1/4" = 1' -0" OR JVITH NI-FA /U - NEC SIP 2 g 2011 City of Tukwila BUILDING DIVISION RECEN CITY OFTU L1+ SEP 19 20b1 PERMIT CENTER SABArchitects 1124 Eastlake Ave East Suite 201 Seattle, WA 98109 Q 206 957 6400 D 206 957 6404 RUSHING Engineering-Essentials-Delivery 1725 WESTLAKE AVE N SUITE 300 SEATTLE, WA 98109 P: (206) 285 -7100 F: (206) 285 -7111 9 -16 -/i 9.16.2011 PANDORA" REVISION N�.iL WESTFIELD SOUTHCENTER 633 SOUTHCENTER STOREFRONT 588 SEATTLE, WA 98188 DATE DESCRIPTION 09 -06-11 CCD -1 09 -16-11 PERMIT REV ELECTRICAL FLOOR PLAN - LIGHTING �L I1ObS7 SCALE: DRAWN: CHECKED: PROJECT NO: 10008.03 E2.02 WP ACU -R 1 WP �08V/30 18.2 MCA P1/14,16,181 ELECTRICAL ROOF PLAN SCALE: 1/4" = 1'-O" GENERAL NOTES: 1. REFER TO MEP COORDINATION SCHEDULE ON SHEET E0.1 FOR WIRING REQUIREMENTS TO MECHANICAL EQUIPMENT. FLAG NOTES: PROVIDE NEW RECEPTACLE ON ROOF WITHIN 30' OF NEW MECHANICAL UNIT. MOUNT ON UNIT IF POSSIBLE. OTHERWISE FIELD VERIFY BEST MOUNTING LOCATION. ALTERNATIVELY, FIELD VERIFY IF A RECEPTACLE IS ALREADY PRESENT WITHIN 30' AND PROVIDE A CREDIT TO THE PROJECT IF AVAILABLE. CIRCUIT TO PANEL P1/22. REVISION N0.1 REVIEWED FOR COMPLIANCE WITH NFPA70 -NEC EP 28 2011 City of Tukwila BUILDING DIVISION RfiCEI,�F� ciT VOF L+ SEP 19 2011 PERMIT CENTER SABA rc h itects 1124 Eastlake Ave East Suite 201 Seattle, WA 98109 0 206 957 6400 Q 206 957 6404 RUS4IINO Engineering-Essentials-Delivery 1725 WESTLAKE AVE N SUITE 300 SEATTLE, WA 98109 P: (206) 285 -7100 F: (206) 285 -7111 9.16.2011 PANDORA' WESTFIELD SOUTHCENTER 633 SOUTHCENTER STOREFRONT 588 SEATTLE, WA 98188 DATE DESCRIPTION 09 -06-11 CCD -1 09 -16-11 PERMIT REV ELECTRICAL ROOF PLAN L.11-0(0S1-7 SCALE: DRAWN: CHECKED: PROJECT NO: 10008.03 E2.03 ABBREVIATIONS A AH] AHU AIC AL C CAT CU DISC (E) EC FA G, GND GC GFI GFQ HP IBC JB kVA KW KCMIL MCB MDP MIN MISC MLA MSB (N) N/A NEC NTS OS PH, 0 Pvc REV SCL SWBD TBB TBD TYP UG UNO VA VFD w WP XFMR Y AMPERE AUTHORI TIES HAVING JURISDICTION AIR HANDLING UNIT AMPERE INTERRUPTING CURRENT ALUMINUM CONDUIT CATEGORY COPPER DISCONNECT EXISTING ELECTRICAL CONTRACTOR FIRE ALARM GROUND GENERAL CONTRACTOR GROUND FAULT INTERRUPTER GROUND FAULT CIRCUIT INTERRUPTER HORSE POWER INTERNATIONAL BUILDING CODE JUNCTION BOX KILOVOLT AMPERE KILOWATT THOUSAND CIRCULAR MILS MAIN CIRCUIT BREAKER MAIN DISTRIBUTION PANEL MINIMUM MISCELLANEOUS MAIN LUGS ONLY MAIN SWITCHBOARD NEW NOT APPLICABLE NATIONAL ELECTRICAL CODE NOT TO SCALE OCCUPANCY SENSOR PHASE POLYVINYL CHLORIDE REVISION SEATTLE CITY LIGHT SWITCHBOARD TELECOMMUNICATIONS BACKBOARD TO BE DETERMINED TYPICAL UNDERGROUND UNLESS NOTED OTHERWISE VOLTS VOLT AMPERES VARIABLE FREQUENCY DRIVE WATT; WIRE WEATHERPROOF TRANSFORMER WYE SCHEMATIC / ONE LINE CURRENT TRANSFORMER WITH METER ENCLOSURE (METER PROVIDED BY UTILITY UNO) 400A/3P CIRCUIT BREAKER 'N— NUMBER OF POLES BREAKER SIZE GROUND CONNECTION MISCELLANEOUS EQUIPMENT AS NOTED GENERIC TAG VOLTAGE HP /MCA MECHANICAL EQUIPMENT TAG FLAG NOTE DETAIL / PLAN IDENTIFIER REVISION CALLOW' CASEWORK TAG FOR EXISTING CONSTRUCTION: EXISTING DEMO NEW DESCRIPTION GI, II '.Ri 1 DUPLEX RECEPTACLE WIRING EXISTING CONDUIT CONDUIT, EXPOSED OR CONCEALED CONDUIT (UNDERGROUND) CONDUIT OR CABLE DOWN o CONDUIT OR CABLE UP CABLE CAPPED CONDUIT CONTINUATION /BREAK ' f HOME RUN - INDICATES PHASE CONDUCTORS INDICATES NEUTRAL - INDICATES GROUND - INDICATES ISOLATED GROUND FEEDER DESIGNATIONS: ( ) 2 "C, 3#1/0, 1#2 GND T I Z GROUND CONDUCTOR QTY & SIZE PHASE CONDUCTOR QTY & SIZE CONDUIT SIZE QTY RUNS LIGHTING WALL SWITCH - SUBSCRIPT INDICATES: 3 = 3 -WAY 4 = 4-WAY M = MOTOR RATED WP = WEATHERPROOF LV = LOW- VOLTAGE NS = NIGHT SETBACK a = LOWER CASE LETTERS INDICATES SWITCHING GROUP DESIGNATION OS = OCCUPANCY SENSOR DIMMER SWITCH OCCUPANCY SENSOR, CEILING MOUNTED F1 NJ FLUORESCENT LIGHT FIXTURE, SIZES VARY. REFER TO 6a,b FIXTURE TYPE TYPICAL ALL FIXTURES: ADJACENT NUMBER INDICATES CIRCUIT GROUPING LOWER CASE LETTER INDICATES SWITCHING GROUP FLUORESCENT FIXTURE ON EMERGENCY CIRCUIT SIZES VARY. REFER TO FIXTURE TYPE. PENDANT FIXTURE RECESSED TRACK HEAD ILLUMINATED EXIT SIGN - SINGLE FACE DIRECTION OF ALL ARROWS AS SHOWN, WHERE INDICATED SEPARATE PERMIT REQUIRED FOR: Mechanical ❑ Electrical r Plumbing tat Gas Piping City of Tukwila FIRE ALARM HORN/STROBE I; ;! 1=r '' EMERGENCY LIGHTING UNIT FIRE ALARM CLG WALL MTD MID 0 Q4 01 FIRE ALARM STROBE OUTLET MOUNTING HEIGHTS SPECIAL OUTLET HEIGHTS ARE SHOWN ON THE ELECTRICAL DRAWINGS OR ON THE ARCHITECTURAL DRAWINGS. IF SPECIAL OUTLET HEIGHTS ARE NOT SHOWN OR REQUIRED, LOCATE OUTLETS AS NOTED BELOW. OUTLET HEIGHTS ARE MEASURED FROM THE CENTERLINE OF THE OUTLET TO THE FINISHED ROAM, UNO. RECEPTACLES +18 INCHES VERTICAL LIGHT SWITCHES +48 INCHES ET VERTICAL PANEL BOARDS +6 FEET TO TOP OF PANEL BOARD TELECOM OUTLET -DESK +18 INCHES VERTICAL TELECOM OUTLET WAU +18 INCHES VERTICAL MANUAL STATION . +48 INCHES VERTICAL FIRE ALARM CONTROL PANEL +6 FEET TO TOP LIRE ALARM VISUAL ALARM LIGHT +80 INCHES OR 6 INCHES BELOW CEILING, WI $EHEVER IS LOWER FIRE ALARM SPEAKER HORN, CHIME +, i INCHES OR 6 INCHES BELOW CEILING, WHEREVER IS LOWER POWER RECEPTACLE OUTLET: SUBSCRIPT NUMBER INDICATES PANEL CIRCUIT NUMBER SUBSCRIPT LETTER INDICATES: WP - WEATHERPROOF DUPLEX RECEPTACLE GFQ DUPLEX RECEPTACLE ABOVE COUNTER DUPLEX RECEPTACLE EQUIPMENT CONNECTION SPECIAL PURPOSE RECEPTACLE, DEVICE RATING AS SHOWN cD J -Box FLOOR BOX, DEVICES AS SHOWN NON -FUSED DISCONNECT SIZE AS INDICATED �30A 4% FUSED DISCONNECT AMP FUSE SIZE (40 AF) AMP SWITCH SIZE (60 AS) ® MOTOR STARTER �+ COMBINATION MOTOR STARTER - DISCONNECT SWITCH ■01 MOTOR CONNECTION MOTOR CONNECTION - 3 PHASE 480Y/277V ELECTRICAL PANEL 208Y/120V ELECTRICAL PANEL PANEL, TYPE AS NOTED LCP - LIGHTING CONTROL PANEL DATA / COMMUNICATION vx TELECOM OUTLET, ONE CAT5E CABLE EACH UNO BY SUBSCRIPT X - QTY CAT5E CABLES CAMERA (BY OTHERS) GENERAL NOTES: 1. ALL ROUGH -IN AND DEVICE MOUNTING HEIGHTS SHALL BE VERIFIED WITH ARCHITECTURAL ELEVATIONS. 2. COMPLY WITH NATIONAL ELECTRIC CODE 2008 AND WAC 296-46. THE LOCATIONS OF ELECTRICAL DEVICES AND LIGHTING FIXTURES INDICATED ON ARCHITECTURAL PLANS AND ELEVATIONS OR SECTIONS TAKE PRECEDENCE OVER LOCATIONS INDICATED ON THE ELECTRICAL DRAWINGS. ELECTRICAL DRAWING INDEX — REVIEWED FOR COMPLIANCE WITH NFPA70 -NEC JUL 23 2011, City of ila BUILDING 1 ISION FILE COPY r+snnh Na, Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Cop :,•:s ion . r owledte - BY Date: toy .2- a7-0 City Of Tukwila BUILDING DIVISION SHEET NUMBER SHEET TITLE SHEET SCALE PERMIT SET 7/19/2011 E0.00 ELECTRICAL SYMBOLS AND ABBREVIATIONS NTS X E0.01 ELECTRICAL RISER & MEP COORDINATION SCHEDULE NTS X E0.02 WSEC ANQ'SWITCH BANK DETAILS NTS X E2.01 ELECTRICAL FLOOR PLAN - POWER & LV 1/4" =1'-0" X E2.02 ELECTRICAL FLOOR PLAN - LIGHTING 1/4" =1' -0" X E2.03 ELECTRICAL ROOF PLAN ^ M 1/4" =1' -0" X E3.00 ELECTRICAL OUTLINE SPECIFICATIONS NTS X REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submitti and may include additional plan review fats.. cttYRAWRIA JUL 20 2011 PERMIT CENTER *E1,110(091 SAB Arch itects 1124 Eastlake Ave East Suite 201 Seattle, WA 98109 0 206 957 6400 Q 206.957 6404 RUSHING Engineering-Essentials- Delivery 1725 WESTLAKE AVE N SUITE 300 SEATTLE, WA 98109 P: (206) 285 -7100 F: (206) 285 -7111 PERMIT SET 7.19.2011 PAN D�RAM WESTFIELD SOUTHCENTER STOREFRONT 588 TUKWILA, WA ELECTRICAL SYMBOLS AND ABBREVIATIONS SCALE: DRAWN: CHECKED: PROJECT NO: 10008.03 E0.00 Project: Subject: Equip. No. PANDORA WESTFIELD MEP COORDINATION SCHEDULE PANEL: PI LOCATION: PANDORA BON VOLTS: 208 Y/ 120 P 3 AIC RATING: 65,000 NEUTRAL: 100% W: 4 STARTER DISCONNECT General Comments Service /Description Location OC PROTECT FEEDER P CIR I! 1 TYPE FURNISHED BY FURNISHED TYPE BY LOAD KVA LOAD TYPE Quantity Voltage phase FRAME TRIP C WIRE MCA TOTAL KW 15 16 15 16 REFRIGERATOR 208V 3 PHASE SECTION REC 0.65 20 1 3 4 1 20 0.50 MISC MICROWAVE CENTER CASEWORK & FRONT CASEWORK REC 0.53 20 1 5 ACU -R -1 ROOF TOP UNIT ROOF 1 208 3 30 30 3/4" 3 #10 &1 #10G 18 6.5 NA 1 20 Fused REC X GENERAL (4) RECBPS IN RETAIL SPACE REC 208V 1 PHASE SECTION 20 1 9 10 1 20 100 M[SC 'VIDEO EQUIP RECEP DHW -2 REC 4.16 50 2 11 n 1 DWH -1 WATER HEATER BATHROOM 1 208 1 30 30 3/4" 2 #10 &1 #10G 20 4.2 NA 2,18 MISC Fused DHW 1 X 2.08 DWH -2 WATER HEATER BACK ROOM 1 208 1 60 50 2" 2 #3/0 & 1 #2G 40 8.3 NA - 17 Fused 18 X - 2.18 120V 1 PHASE SECTION - RETAIL LIGHTING LTG 1.11 20 1 19 A B C A B 20 1 20 0.08 MTR EXHAUSTFAN RETAIL LIGHTING LTG 123 EF -1 BATHROOM EXHAUST L1 1 120 1 20 15 1/2" 2 #12 & 1 #12G 1 0.08 20 1 X 24 1 20 occup lied by occupancy sensor 20 1 25 26 1 20 20 1 MAIN ELECTRICAL ROOM 1■ ww MIMEO w w w- w w w --m. w w w wiw w w w .-w w w w MEMO w I w w■ w ww 1 1 1 1 w w w -w w w ww.ww -. www w-. ■■•■■• rw w -r- w w w1 1 piEfak 1 SECION 2 SECION 3 SECION 4w SECION 5 SEN Tikiiiiii SECION S 1 �I 7 T j&&7 1 �1 I 1 1 1 1 1 1 1 1 1 1 1 1 1-: 2. 1 1 I 1 1 1 1 l® a 1 1 1 I 1 I 1 I 14 I 1 1 I 1 1 1 1 1 1 Ili .4) 1 1 1 1 1 1 1 1 1 1 1 1 1 1 rre` �N• i 1 `' `' f I 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 INCOMING' 1 I 1 1 (6) EXST 1 1 1 I 1 LSE� wlw 1 L �MErERS J J J 1 www www w w wi.-www wwww w.rwww www ww ww.ww -.wwww I 1 MAIN DISTRIBUTION PANEL 1 1ST FLOOR 1 3000A,208Y/120V, 65kAIC I NEW PANDORA BACK OFFICE NO OM* -w-w w w MOWN www =MOM www - -1 P1 208V 100A PANEL SCHEDULE PANEL: PI LOCATION: PANDORA BON VOLTS: 208 Y/ 120 P 3 AIC RATING: 65,000 NEUTRAL: 100% W: 4 AMP: 100 MLOD MCB X MOUNT: X SURFACE FLUSH TYPE: EXISTING X NEW❑ STYLE: FED FROM: 1 LOAD CIRCUIT DESCRIPTION TYPE LOAD KVA CET DKR P CIR I! 1 P H CM # r Off BER LOAD KVA LOAD TYPE CIRCUITDESCRUW7'ION BAST CASEWORK REC 0.84 20 1 1 A B C A B C A B 2 1 20 0.75 MISC REFRIGERATOR WEST CASEWORK REC 0.65 20 1 3 4 1 20 0.50 MISC MICROWAVE CENTER CASEWORK & FRONT CASEWORK REC 0.53 20 1 5 6 1 20 1.00 MisC STEAMER DUPLEX CASHWRAP (2) QUADS REC 0.72 20 1 7 8 1 20 1.08 REC BOH GENERAL (6) RECEPS GENERAL (4) RECBPS IN RETAIL SPACE REC 0.72 20 1 9 10 1 20 100 M[SC 'VIDEO EQUIP RECEP DHW -2 REC 4.16 50 2 11 n 1 20 0.72 RBC BOH (2) QUADS - REC 4.16 - - 13 14 3 30 2,18 MISC ACU -R 1 DHW 1 REC 2.08 30 2 15 16 - - 2.18 MISC - - REC 2.08 - - 17 C 18 - - 2.18 MISC - RETAIL LIGHTING LTG 1.11 20 1 19 A B C A B 20 1 20 0.08 MTR EXHAUSTFAN RETAIL LIGHTING LTG 123 20 1 21 22 1 20 0.18 REC ROOF RECEP 20 1 23 24 1 20 20 1 25 26 1 20 20 1 27 28 1 20 20 1 29 C A B C A B C 30 1 20 20 1 31 32 1 20 20 1 33 34 1 20 20 1 35 36 1 20 20 1 37 38 1 20 20 1 39 40 1 20 20 1 41 42 1 20 ESTIMATED MAXIMUM DEMAND (EMD) CALCULA7'!ONS LOAD SUMMARY: LOAD TYPE: CONNECTED NEC DEMAND CONNECTED PHASE LOADING LIGHTING LTG 2.34 KVA RESIDENTLTG/RECPT RES 0.00 KVA SMALL APPLIANCE RES 0.00 KVA LARGEST MOTOR 0.00 KVA REMAINING MOTORS MTR 0.08 KVA GEN PURPOSE RECPf REC 18.13 KVA COMPUTER RECPF MISC 0.00 KVA EQUIP/OTHER MISC 9.79 KVA HEATING MISC 0.00 KVA ELEVATOR ELEV . 0.00 KVA K1tCHEN EQPT ETCH 0.00 KVA 2.93 KVA (125%) 0.00 KVA (100/35/25 %) 0.00 KVA ( 100/35/25 %) 0.00 KVA (125 %) 0.08 KVA (100%) 14.06 KVA (50%> 10KVA) 0.00 KVA (100%) 9.79 KVA (100%) 0.00 KVA (100%) 0.00 KVA @ 100% 0.00 KVA @ 65% 26.86 KVA 7435 AMPS AT INDICATED DEMAND AT 100% PHASE A: 10.92 KVA PHASE IR 8.74 KVA PHASE C: 10.67 KVA NOTES: 1 NOTES TOTALS 30.34 KVA 84.20 AMPS LOAD TYPENOTES: "COMB" = COMBINATION LOAD TYPES ON INDICATED CIRCUIT "RES" = RESIDENTIAL LTG/RECPC OR SMALL APPLIANCE LOAD TAKEN "MISC" = EQUIP, COMPUTER. REC OR HTG LOAD ON INDICATED CIRCUIT w w w -w w w ww.ww -. www w-. ■■•■■• rw w -r- w w w1 1 piEfak 1 SECION 2 SECION 3 SECION 4w SECION 5 SEN Tikiiiiii SECION S 1 �I 7 T j&&7 1 �1 I 1 1 1 1 1 1 1 1 1 1 1 1 1-: 2. 1 1 I 1 1 1 1 l® a 1 1 1 I 1 I 1 I 14 I 1 1 I 1 1 1 1 1 1 Ili .4) 1 1 1 1 1 1 1 1 1 1 1 1 1 1 rre` �N• i 1 `' `' f I 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 INCOMING' 1 I 1 1 (6) EXST 1 1 1 I 1 LSE� wlw 1 L �MErERS J J J 1 www www w w wi.-www wwww w.rwww www ww ww.ww -.wwww I 1 MAIN DISTRIBUTION PANEL 1 1ST FLOOR 1 3000A,208Y/120V, 65kAIC I NEW PANDORA BACK OFFICE NO OM* -w-w w w MOWN www =MOM www - -1 P1 208V 100A SCHEDULE NOTES 1. Conduit sizing based on Rigid Galvanized Steel Conduit, Type THW wire taking into account both conduit fill & Jamb ratio. 2. Ampacities (NEC Table 310 -16) are based on the following: a. 75° Rating for wire sizes upto & including AWG #1. b. 90° rating for 5W feeders de -rated to 80 %where predominantly harmonic currents are present. Neutrals > or = to 1/0 are paralleled on 5W feeders. 3. Increase raceway size for other types of raceways & difficult or long pulls. 4. Set of Phase, Neutral and Ground conductors are to be installed in each raceway noted. REVIEWEDFON COMPLIANCE WITH NFPA 70 - NEC JUL 2 3 2011 City of Tukwila BUILDING DIVISION SECTION 6 METER INFORMATION: 1. HDS SPACE #576, SUITE 1: 200A/3P 2. LA CHATEL SPACE #580, SUITE 504: 200A/3P 3. SPARE, 200A/3P 4. FRANCESCA'S COLLECTION, SUITE 611: 100A/3P 5. CHAROLETTE RUSSE, SUITE 621: 200A/3P 6. EXISTING MS STORE (NEW PANDORA METER), SUITE 516: 100A/3P FLAG NOTES: WORK BY LANDLORD AS DESCRIBED IN THE WESTFIELD MALL ENGINEERING CRITERIA MANUAL: PULL BACK EXISTING 90A FEEDER TO PANEL P1 IN PANDORA SPACE. PULL NEW 100A FEEDER THROUGH EXISTING CONDUIT IF POSSIBLE. OTHERWISE, PROVIDE NEW CONDUIT FROM EXISTING 100A METER SOCKET (POSITION 6 IN SECTION 6 IN MAIN ELECTRICAL ROOM) TO EXISTING PANEL FOR PANDORA SPACE. REMOVE EXISTING 90A MCB IN PANEL P1. PROVIDE NEW 100A MAIN CIRCUIT BREAKER IN PANEL P1. EC TO PROVIDE NEW CIRCUIT BREAKERS AS NECESSARY TO ACCOMODATE NEW EQUIPMENT IN PANDORA SPACE. EL\\Obs7cn�„ .I1.1L 2 0-2011 PERMIT CENTER SA BArchitects 1124 Eastlake Ave East Suite 201 Seattle, WA 98109 0 206 957 6400 0 206 957 6404 RUSHING Engineering- "'Essentials- Delivery 1725 WESTLAKE AVE N SUITE 300 SEATTLE, WA 98109 P: (206) 285 -7100 F: (206) 285 -7111 PERMIT SET 7.19.2011 PAND�RAM WESTFIELD SOUTHCENTER STOREFRONT 588 TUKWILA, WA ELECTRICAL RISER & MEP COORDINATION SCHEDULE SCALE: DRAWN: CHECKED: PROJECT NO: 10008.03 E0.01 COPPER FEEDER SCHEDULE, 34 XFMR 4800 PANELS XFMR 208Y/120V MAX LOAD AMPS SYSTEM TAG NO. OF RACEWAYS RACEWAY SIZE PHASE CONDUCTORS NEUTRAL GROUND AMPS/COND AMPS CB 100A 76 4W 100.4 1 1-1/4" 3 #2 1 #2 1 #8 95 95 100 SCHEDULE NOTES 1. Conduit sizing based on Rigid Galvanized Steel Conduit, Type THW wire taking into account both conduit fill & Jamb ratio. 2. Ampacities (NEC Table 310 -16) are based on the following: a. 75° Rating for wire sizes upto & including AWG #1. b. 90° rating for 5W feeders de -rated to 80 %where predominantly harmonic currents are present. Neutrals > or = to 1/0 are paralleled on 5W feeders. 3. Increase raceway size for other types of raceways & difficult or long pulls. 4. Set of Phase, Neutral and Ground conductors are to be installed in each raceway noted. REVIEWEDFON COMPLIANCE WITH NFPA 70 - NEC JUL 2 3 2011 City of Tukwila BUILDING DIVISION SECTION 6 METER INFORMATION: 1. HDS SPACE #576, SUITE 1: 200A/3P 2. LA CHATEL SPACE #580, SUITE 504: 200A/3P 3. SPARE, 200A/3P 4. FRANCESCA'S COLLECTION, SUITE 611: 100A/3P 5. CHAROLETTE RUSSE, SUITE 621: 200A/3P 6. EXISTING MS STORE (NEW PANDORA METER), SUITE 516: 100A/3P FLAG NOTES: WORK BY LANDLORD AS DESCRIBED IN THE WESTFIELD MALL ENGINEERING CRITERIA MANUAL: PULL BACK EXISTING 90A FEEDER TO PANEL P1 IN PANDORA SPACE. PULL NEW 100A FEEDER THROUGH EXISTING CONDUIT IF POSSIBLE. OTHERWISE, PROVIDE NEW CONDUIT FROM EXISTING 100A METER SOCKET (POSITION 6 IN SECTION 6 IN MAIN ELECTRICAL ROOM) TO EXISTING PANEL FOR PANDORA SPACE. REMOVE EXISTING 90A MCB IN PANEL P1. PROVIDE NEW 100A MAIN CIRCUIT BREAKER IN PANEL P1. EC TO PROVIDE NEW CIRCUIT BREAKERS AS NECESSARY TO ACCOMODATE NEW EQUIPMENT IN PANDORA SPACE. EL\\Obs7cn�„ .I1.1L 2 0-2011 PERMIT CENTER SA BArchitects 1124 Eastlake Ave East Suite 201 Seattle, WA 98109 0 206 957 6400 0 206 957 6404 RUSHING Engineering- "'Essentials- Delivery 1725 WESTLAKE AVE N SUITE 300 SEATTLE, WA 98109 P: (206) 285 -7100 F: (206) 285 -7111 PERMIT SET 7.19.2011 PAND�RAM WESTFIELD SOUTHCENTER STOREFRONT 588 TUKWILA, WA ELECTRICAL RISER & MEP COORDINATION SCHEDULE SCALE: DRAWN: CHECKED: PROJECT NO: 10008.03 E0.01 r 6" NORTH LIGHTING ob SOUTH LIGHTING OG 0 D3ate . 7/12/2011 s oserscat 589 e t'*.,Ua. WA e e Applicant Phexte: 201.799.457e Project Dee®cripiHon ® New Hulking 0 Addflcn C1 Alteration • indr,del Refer to W ` -C Section 1513 for controls and commissioning requirements. 100111}l7alCe " o n ens) • Prssciptly e • Lighting Power Allowance • Syetern9 Anatnis I (See Qualification Checklist (over), Mdicate Prescriptive & LPAspaces *tidy at p Alteration Exceptions (cheek appNopr••• box - sec. 1132.3) a No changes are being made to the lighting and space use not changed • Less than 60%d the fixtures new, installed wattage nal increased, & space use not changed. 1nDDATIODUL Wet tap DAM AREA o 311 e e e e 64 • 128 e t i DEcuaRTIVE Iwmarr NORTH LIGHTING ob SOUTH LIGHTING OG WALL WASHERS CENTRAL MERCHANDISE Oe TRACK UGHTS sf LINE VOLTAGE SWITCH BANK DETAIL SCALE: NOT TO SCALE INTERIOR INTERIOR WINDOW EXTERIOR CASEWORK LIGHTS UGHTS LIGHTS SIGN LOW VOLTAGE SWITCH DETAIL SCALE: NOT TO SCALE 2009 Washin, • n State Ene Code Co Lance Form for Nonresidential and Mul#famli Residential Interior Lighting Summary LTG-INT project info e D3ate . 7/12/2011 s oserscat 589 e t'*.,Ua. WA e ApplicentAddress". 1726 rosilek• avenue Meath Applicant Phexte: 201.799.457e Project Dee®cripiHon ® New Hulking 0 Addflcn C1 Alteration • indr,del Refer to W ` -C Section 1513 for controls and commissioning requirements. 100111}l7alCe " o n ens) • Prssciptly e • Lighting Power Allowance • Syetern9 Anatnis I (See Qualification Checklist (over), Mdicate Prescriptive & LPAspaces *tidy at p Alteration Exceptions (cheek appNopr••• box - sec. 1132.3) a No changes are being made to the lighting and space use not changed • Less than 60%d the fixtures new, installed wattage nal increased, & space use not changed. 1nDDATIODUL Wet tap DAM AREA 0.60 311 e e e WALL WASHERS CENTRAL MERCHANDISE Oe TRACK UGHTS sf LINE VOLTAGE SWITCH BANK DETAIL SCALE: NOT TO SCALE INTERIOR INTERIOR WINDOW EXTERIOR CASEWORK LIGHTS UGHTS LIGHTS SIGN LOW VOLTAGE SWITCH DETAIL SCALE: NOT TO SCALE 2009 Washin, • n State Ene Code Co Lance Form for Nonresidential and Mul#famli Residential Interior Lighting Summary LTG-INT project info PrnledAddfress tanaoaa raettleld Enid D3ate . 7/12/2011 s oserscat 589 For Suik rig Depatment Use t'*.,Ua. WA Applicant Name: Maley Ltsamenbuek ApplicentAddress". 1726 rosilek• avenue Meath Applicant Phexte: 201.799.457e Project Dee®cripiHon ® New Hulking 0 Addflcn C1 Alteration • indr,del Refer to W ` -C Section 1513 for controls and commissioning requirements. 100111}l7alCe " o n ens) • Prssciptly e • Lighting Power Allowance • Syetern9 Anatnis I (See Qualification Checklist (over), Mdicate Prescriptive & LPAspaces *tidy at p Alteration Exceptions (cheek appNopr••• box - sec. 1132.3) a No changes are being made to the lighting and space use not changed • Less than 60%d the fixtures new, installed wattage nal increased, & space use not changed. Maximuum. Allowed Lighting Wattage Looatkin (floor pannoom r8) Occupancy Desolption Allowed Watts Der 112 " Sanwa ornerier keie in le Allowed X Area LEVt1. l RATA= a acrr 1.33 951 3.268 LS ADDITIONAL s'let tans sUMSnDMx 52en211i6 2.50 420 r 120a Li 1nDDATIODUL Wet tap DAM AREA 0.60 311 187 "'From From Tabbies 15.1(o+nr) - document a$I exceptions cn form LTG-LPA Total Allowed Watt 2651 Proposed Lighting Wattage Location (floor plank oom 8) Fixture Description Number of Mures Watts/ Fbttum Watts Proposed LEVt1. l 1m scones mats Vitt) air LED MEADS, VIDE seMa►v 12 60. 720 LEVEL 1 t2 i WNW ISM 11/(2) 3012 LED MEADE, J2RPOr 9 60 540 WA 1 Rl t ACCENT trtSRP W/ (i) VW MAD 7 18 126 L18VML 1 p8: MECUM U LL VMMA r /(l) LED MEAD 2 64 • 128 Laves 1 t i DEcuaRTIVE Iwmarr 2 150 300 LEVU 1 xtt LW (MACK MAW (5eMUM tat e*YLCM, . 4 50 200 Lay r. a Mt t,xe= s r 110O21e(1e51 3 84 192 matt 1 OtOwsrMow UMW: 1 200. 200 Indicate separate controls N.A. 15133 6deriar shut -off Schedule with type and features, indicate location F.A. (a) timer w kup Indicate location To Proposed Waits mey not exceed TOM Alkfwed Welts for Intoner Total Proposed Wstti 2406 State Energy Code Compliance Form for Nonreaidenbai and Mu€Itfarnaiy Rebid Lighting, Motor, and Transformer Permit Hans Checklist LTG -CHK 2009 was *i.ton istida Energy Coda Compliance Forms fir Nerameldwalal and lMul itemly RsaldexMlal Revised Novenber 2010 Pretend Address tandem* Ws tt te1d Mall 7/12/2011 The ffrillaMng Intimation is necessary to deck a puma application for comp ante with the lighting, mdor, Ind trausfarmer requirements in the 2009 Washington Abe Nonresidential sideMntial Energ, Code. ApplIcabilty Code (yes, no, n.a.) Section Component Information Requirec Locttcn on Plans Bulking Department Notes LIGHTING CONTROLS (Section 1513 Tee 1513.1 Local control/access S ale with type, indicate Locations Yes 1 132 Area =drab Maximum limit per swlten N.A. 1513.3 Daylight zone control Schedule with type and features, indicate locations R.A. vertical glazing Indicate vertical glaang an plans F.A, overhead glazing Mdicate overhead glazing cn plans Yes 1513.4 Di splayiexhibISpedal Indicate separate controls N.A. 15133 6deriar shut -off Schedule with type and features, indicate location F.A. (a) timer w kup Indicate location N .A. (b) photoaeN. Wirete location Yes 1513.6 inter. auto shut -oar tndieate location Toe 1513,6 (M) vaccup. sensors Schedule with type and locations Y ss 151346.2 (b) auto switches Schedule with type and features (back -up, override capability); indicate size of zone en plans F.A. 1513,7 Hotel/Instal controls indicate location of room master controls Yes 1513.a Commissionixng _ Indicate requirements for fighhting controls commissioning EXIT SIGNS (Section 1614I Yea 1 1514 1Max. wens Indicate traits for each exit sign J LIGHTING POWER ALLOWANCE Section 1530.1632 tfsa 4 liti! ' wltr idfuro t�pea Blasts, watts • fixture F.A. MI Extedor Lighting Summery Form Completed and attached. Schedule with 1bdure types, beeps, beiluuts, watts per fixture MOTORS Section 1811 II .A. 1511 Elea motor efficiency MECH -MOT or Emfipment Schedule with to, rpm, ellcterlcy TRANSFORMERS (Section 1540) a .A. 1540 1 anttormers knd Ste size and efficiency If "no" is circled for any question, provide explanation: REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC JUL 23 2011 City of Tukwila BUILDING DIVISION 4•LII%ft• DIo57 crtra JUL 2 0 2011 PERMIT CENTER S A B A rc h itects 1124 Eastlake Ave East Suite 201 Seattle, WA 98109 Q 206 957 6400 0 206 957 6404 RUSHING Engineering-Essentials-Delivery 1725 WESTLAKE AVE N SUITE 300 SEATTLE, WA 98109 P: (206) 285 -7100 F: (206) 285 -7111 PERMIT SET 7.192011 PAN D�RAM WESTFIELD SOUTHCENTER STOREFRONT 588 TUKWILA, WA WSEC AND SWITCH BANK DETAILS SCALE: DRAWN: CHECKED: PROJECT NO: 10008.03 E0.02 Clo 0 D FB A A P1 /5, VIA RELAY 4 P1 /5, VIA RELAY 4 1'I i► l;Rl -17R11-- •' l;IU ED) Eloggimi 0 iirim !T• mm MEM -- -Cis -- sr:2 D m i'► P111, VIA RELAY 1 FB 5,R3 P1 /5, VIA RELAY 3 ii) P1 /5, VIA ■ i RA ORE C 100 ) 774 SF LAY3 ED Go /1 C6 GO iJ ;:t 1,R1 1,R1 P1 P1/7 P1 /3, VIA av"""°...-- RELAY 2 3/R2 3,R2 iii.. A ' ANIMINVAIW MINIMUM IN r JbE»0 4 O V V .oi worm r illt . EQI BACKRC1OI%a ' C. 101 ) 10 sJ 12 8 MW +66" 66' 10 DHW -2 REI? r 1 RESTPOOM 11 208V/10 8.32 KW 13 HALLWAY AEVIEWEL) I-0Ih COMPLIANCE WITH NFPA70 -NEC JILL 28 2011 City of Tukwila. BUILDING DIVISION DHW -1 208V/10 4.16 KW P1/15,17 CASEWORK SCHEDULE Tag Casework Name Quantity Connection Type AFF W /Unit . Comments C1 UD.1 Receptacle - 72W Located next to a SEK.2 or 3, plugs directly into SEK.2 or 3. C2 SP.1 Receptacle 18" 36W Cord provided with casweork assembly. Plugs into standard duplex. C3 SEK.2 Hardwired 18" 54W Casework hardwired to junction box recessed in wall. C4 SEK.3 Hardwired 18" 81W Casework hardwired to junction box recessed in wall. C5 PL.1 Receptacle 50" 24W TV unit plugs directly into receptacle. C6 GL.1 Floorbox - 30W Cord provided with casweork assembly. Plugs into duplex located in a floorbox, or daisy chain to adjacent equipment. C7 GL.2 Floorbox - 30W Cord provided with casweork assembly. Plugs into duplex located in a floorbox, or daisy chain to adjacent equipment. C8 GL.3 Floorbox - 30W Cord provided with casweork assembly. Plugs into duplex located in a floorbox, or daisy chain to adjacent equipment. C9 GL.5 Floorbox - 30W Cord provided with casweork assembly. Plugs into duplex located in a floorbox, or daisy chain to adjacent equipment. C10 HJ.4 Floorbox - 24W Cord provided with casweork assembly. Plugs into duplex located in a floorbox, or daisy chain to adjacent equipment. C11 WIN.3A Floorbox - 12W Casework located in front window. Provide a floor mounted NEMA L5 -20R receptacle located below the left leg from the customer side. C12 WIN.3B Receptacle 36" 12W Casework located adjacent to a wall. Provide a flush mounted NEMA 15 -20R located at 36" AFF C13 JT.2 Floorbox - 54W Cord provided with casweork assembly. Plugs into duplex located in a floorbox. Cord comes from underneath the right leg from the customer side EF-1 120V/10 80W \\P1/8 MEN TRASH ELECTRICAL FLOOR PLAN - POWER & LOW VOLTAGE ED * S AB Architects GENERAL NOTES: 1. ALL CASEWORK RECEPTACLES THAT CONTAIN LIGHTING TO BE ON A RELAY TO SHUT OFF DURING UNOCCUPIED HOURS. OVERRIDE SWITCH TO BE PROVIDED IN BACK OFFICE. REFER TO SHEET E2.02 FOR RELAY SCHEDULE. CCTV CAMERAS TO BE PROVIDED BY AND INSTALLED BY CAMERA VENDOR, AND ARE POWERED BY VIDEO EQUIPMENT IN BACK. VENDOR TO PROVIDE CABLING TO EQUIPMENT. SHOWN ON PLANS FOR LOCATION ONLY. 3. ELECTRICIAN TO PULL CAT5E TO ALL TELECOM LOCATIONS FROM THE EXISTING TELECOM BACKBOARD. TERMINATIONS WILL BE DONE BY THE PHONE INSTALLER. 4. ALL FIRE ALARM DEVICES TO BE TIED IN TO EXISTING BUILDING FA SYSTEM. REFER TO MEP COORDINATION SCHEDULE ON SHEET E0.1 FOR WIRING REQUIREMENTS TO MECHANICAL EQUIPMENT. 6. REFER TO ARCHITECTURAL DRAWINGS FOR DEVICE LOCATIONS AND ELEVATIONS. 7. PROVIDE CONDUIT AND WIRE FOR CIRCUITING SHOWN. 1 /2 "C, #12AWG OR MC CABLE AS PERMITTED BY LANDLORD. FLAG NOTES: SAW CUT SLAB FOR CONDUIT AND WIRING ROUTING TO FLOOR BOX LOCATION. CONFIRM FLOOR BOX LOCATION WITH CASEWORK PRIOR TO TRENCHING. SAW CUT SLAB AND PROVIDE 3/4 "C TO SERVE TELECOM CABLING TO TELECOM OUTLETS LOCATED ON FLOATING CASEWORK. CONFIRM TELECOM ROUTE PRIOR TO PERFORMING ANY WORK. CONFIRM LOCATION OF OUTLETS WITH ARCHITECT PRIOR TO ROUGH PROVIDE WATTSTOPPER LP12 OR EQUIVALENT RELAY PANEL. PROVIDE TELEPHONE BACK BOARD FOR PHONE SYSTEM IF REQUIRED. CONFIRM REQUIREMENTS WITH PANDORA AND TELECOM PROVIDER PRIOR TO INSTALIATLONI PROVIDE SURFACE MOUNTED DUPLEX RECEPTACLES FOR CASH REGISTER AND COMPUTER LOCATED ON CASEWORK. FELD VERIFY LOCATION OF RECEPTACLES IN CASEWORK AND CONFIRM WITH ARCHITECT PRIOR TO ROUGH -IN. SAW CUT SLAB FOR (2) 3/4" CONDUITS TO CASEWORK RECEPTACLES. EXISTING 208Y/120V, 90A, 65kAIC PANEL "P1" TO BE RELOCATED TO EXISTING LOCATION SHOWN BY OWNER AND RE -USED FOR THE NEW PANDORA SPACE. PANEL TO BE. UPSIZED. REFER TO RISER FOR ADDITIONAL DETAILS. EXHAUST FAN TO BE CONTROLLED BY OCCUPANCY SENSOR SWITCH. SEE E2.02. CASEWORK DAISY CHAINED TOGETHER AND PLUGGED INTO FLOOR BOX. PLUG AND CORD PROVIDED WITH CASEWORK. ELl1O7 •• cxry JUL 20 2011 PERMIT CENTER 1124 Eastlake Ave East Suite 201 Seattle, WA 98109 Q 206 957 6400 Q 206 957 6404 RUSHING Engineering -- Essentials - Delivery 1725 WESTLAKE AVE N SUITE 300 SEATTLE, WA 98109 P: (206) 285 -7100 F: (206) 285 -7111 PERMIT SET 7.19.2011 PAN D�RAM WESTFIELD SOUTHCENTER STOREFRONT 588 TUKWILA, WA ELECTRICAL FLOOR PLAN - POWER & LOW VOLTAGE SCALE: DRAWN: CHECKED: PROJECT NO: 10008.03 E2.01 OMB 21f 21f 19b fri 21DEM1 0 21e i9c • 19b 19b m 21e 21e N2 2143 21e 19c 19b N2 N2 ® m 21e 21e 21DEM1 Ei3 21e 21e 21e 19c 19c 19b 21a N1 21e ED 19c tI3 19b E13 0 19b a 19b 0 19c 4 19d 19d AirrAmmi 19 LIGHTING FIXTURE SCHEDULE Tag # Lamps Lamp Type Wattage Mfger Fixture Cat. No. Fixture Description P 1 T10 HALOGEN 150 FLOS ZEPPELIN S1- FU980009 Dimmable Decorative chandelier for focal areas. Dimensions: 43.3" X 29 "H. Confirm mounting height with architect. N1 1 LED 30 Amerlux C3R -1 -26- LED -E -WT 120- FL -WT- 3000 -DIM Dimmable White LED retail accent light with electronic constant current LED driver and (1) head. Confirm beam spread with architect. N2 2 LED 60 Amerlux C3R -2 -26- LED -E -WT- 120- FL -FL -WT 3000 -DIM Dimmable White LED retail accent light with electronic constant current LED driver and (2) heads. Confirm beam spread with architect. W 2 LED 60 Amerlux C3R- 2- 26- LED -E -WT 120- WF- WF -WT- 3000 -DIM Dimmable White LED retail accent light for main pathways with electronic constant current LED driver and (2) heads. Confirm beam spread with architect. W3 1 LED 68 Amerlux CAV- 11 -64- LED -E -WT- 120 -WF- 3000 Recessed adjustable graphic LED wall washer for back wall. High performance aluminum heat sink with white powder coat paint. Confirm beam spread with architect. B 2 CFL 64 Metalux 2GR8- 232- A- UNV -EB8 Recessed 2x4 Fluorescent with 12) T8 lamps for back of house space. T - - - Amerlux GES204 -3 Track for window lights. Confirm track length with architect. T1 1 LED 35 Amerlux C3TV 30- LED -E -WT TN1- 120 -FL- 3000 -DIM Dimmable White LED track heads along window display. Confirm beam spread with architect. EX 1 LED 0.71 Lithonia LQM- S- W -EL -N Termoplastic LED exit sign with emergency operation. Provide white with green lettering. EXE 1 LED 3.7 Juno NXESBA- 1 -G -WH Surface mount edge -lit exit sign with battery back -up and green letters and white finish. EM 2 5.4W, 6V lamps 10.8 Lithonia ELM Back of house emergency lighting unit. White thermoplastic quick mount unit with lead- calcium battery. EM1 2 20W LED 45 Sure -Lites CEL- 4020 -70 -120 Sales floor concealed emergency lighting with sealed lead calcium battery with 120 minutes of run time. ELECTRICAL FLOOR PLAN - LIGHTING REVIEWED _i-Ui COMPLIANCE ITH NFPA 70 JUL 2 8 2011 City BUILDING DIVISION Ci of Tukwila GENERAL NOTES: PROVIDE UNSWITCHED CIRCUIT TO EXIT SIGNS AND EMERGENCY LIGHTING UNITS. 2. ALL UGHTING IN RETAIL SPACE TO BE ON A RELAY TO SHUT OFF ALL UGHTING DURING UNOCCUPIED HOURS. OVERRIDE SWITCH TO BE LOCATED IN BACK ROOM. REFER TO RELAY SCHEDULE FOR RELAY ZONES. 3. CIRCUIT ALL UGHTING TO PANEL P1. REFER TO PLAN FOR CIRCUIT NUMBERS /LINE VOLTAGE SWITCH LEGS. 4. PROVIDE CONDUIT AND WIRE FOR CIRCUITING SHOWN. 1 /2 "C, #12AWG OR MC CABLE AS PERMITTED BY LANDLORD. FLAG NOTES: PROVIDE ELECTRICAL CONNECTION TO SIGNAGE LIGHTING. CIRCUIT TO PANEL P1 /21 VIA RELAY 5. PROVIDE A DOUBLE GANG BOX WITH (5) LOW VOLTAGE OVERRIDE PUSH BUTTONS TO INTERFACE WITH RELAYS, WATTSTOPPER #RS OR EQUIVALENT. REFER TO LOW VOLTAGE SWITCH DETAIL ON SHEET E0.02. PROVIDE LABELS AS SHOWN IN DETAIL REFER TO SW11CH BANK DETAIL ON SHEET EO.02 FOR LINE VOLTAGE SWITCH DETAILS. CONTRACTOR TO PROVIDE LABELS AS SHOWN IN DETAIL. LIGHTING CONTROL PANEL: LCP 1 208Y/120V RELAY LOCATION SERVED FIXTURE TYPE(S) CIRCUIT CONTROL ON OFF OVERRIDE 1 EAST CASEWORK - P1/1 TC TC S 2 WEST CASEWORK - P1/3 TC TC S 3 CENTRAL CASEWORK - P1/5 TC TC S 4 WINDOW CASEWORK - P1/5 TC TC S 5 STOREFRONT SIGNAGE - P1/21 TC TC S 6 WINDOW LIGHTING T1, N1 P1121 TC TC S 7 STORE LIGHTING W, N1, W3 P1/19 TC TC S 8 STORE LIGHTING (CENTRAL) N1, N2, P P1/21 TC TC S 9 SPARE 10 SPARE 11 SPACE 12 SPACE ABBREVIATIONS: TC = TIMECLOCK (ASTRONOMICAL) S = LOW VOLTAGE SWITCH PC = PHOTO CELL PS = PHOTO SENSOR OS = .00CUPANCY SENSOR SCALE: 1/4" =1'-0" O'57 crry JUL 2 0 2011 PERMIT CENTER SABArchitects 1124 Eastlake Ave East Suite 201 Seattle, WA 98109 0 206 957 6400 0 206 957 6404 RUS -SING Engineering-Essentials-Delivery 1725 WESTLAKE AVE N SUITE 300 SEATTLE, WA 98109 P: (206) 285 -7100 F. (206) 285 -7111 PERMIT SET 7.19.2011 PAND�RAM WESTFIELD SOUTHCENTER STOREFRONT 588 TUKWILA, WA ELECTRICAL FLOOR PLAN - LIGHTING SCALE: DRAWN: CHECKED: PROJECT NO: 10008.03 E2.02 WP egi ACU -R -1 WP -208W30 18.2 MCA P1/14,16,18 ELECTRICAL ROOF PLAN REVIEWEt) f-Oh COMPLIANCE WITII NFPA 70 - NEC AIL 2 8 2011 City of .Tukwila BUILDING DIVISION SCALE: 1/4" =1' -0" GENERAL NOTES: 1. REFER TO MEP COORDINATION SCHEDULE ON SHEET E0.1 FOR WIRING REQUIREMENTS TO MECHANICAL EQUIPMENT. FLAG NOTES: PROVIDE NEW RECEPTACLE ON ROOF WITHIN 30' OF NEW MECHANICAL UNIT. MOUNT ON UNIT IF POSSIBLE. OTHERWISE FIELD VERIFY BEST MOUNTING LOCATION. ALTERNATIVELY, FIELD VERIFY IF A RECEPTACLE IS ALREADY PRESENT WITHIN 30' AND PROVIDE A CREDIT TO THE PROJECT IF AVAILABLE. CIRCUIT TO PANEL P1/22. ELlO(oS7 cnYRNSIu JUL 20 7011 PERMPTCENTER SA BArchitects 1124 Eastlake Ave East Suite 201 Seattle, WA 98109 0 206 957 6400 0 206 957 6404 RUSHING Engineering - Essentials- Delivery 1725 WESTLAKE AVE N SUITE 300 SEATTLE, WA 98109 P: (206) 285 -7100 F: (206) 285 -7111 PERMIT SET 7.19.2011 PA.N D�RA1M WESTFIELD SOUTHCENTER STOREFRONT 588 TUKWILA, WA ELECTRICAL ROOF PLAN SCALE: DRAWN: CHECKED: PROJECT NO: 10008.03 E2.03 1 r ELECTRICAL OUTLINE SPECIFICATIONS SECTION 2600 00 -1 PANDORA JULY 18, 2011 SECTION 26 05 03 EQUIPMENT WIRING CONNECTIONS t PROVIDE EQUIPMENT CONNECTIONS AND COORDINATION IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. 2. OBTAIN AND REVIEW SHOP DRAWINGS, PRODUCT DATA, MANUFACTURER'S WIRING DIAGRAMS, AND MANUFACTURER'S INSTRUCTIONS FOR EQUIPMENT FURNISHED UNDER OTHER SECTIONS. 3. DETERMINE CONNECTION LOCATIONS AND REQUIREMENTS. 4. SEQUENCE ROUGH -IN OF ELECTRICAL CONNECTIONS TO COORDINATE WITH INSTALLATION OF EQUIPMENT. 5. SEQUENCE ELECTRICAL CONNECTIONS TO . COORDINATE WITH START -UP OF EQUIPMENT. SECTION 26 0519 LOW VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES 1. PROVIDE BUILDING WIRE AND CABLE AND METAL CLAD CABLE; AND WIRING CONNECTORS AND CONNECTIONS. 2. IN DOOR WIRING SHALL BE THHN OR THWN. 3. OUTDOOR WIRING IN CONDUIT SHALL BE TYPE THWN. 4. WIRING SHALL BE CU. STRANDED FOR #8 AND LARGER; SOLID OR STRANDED FOR #10AWG; SOLID FOR #12AWG AND SMALLER. 5. INSULATION RATING 600V. 6. PROVIDE CONDUIT AND WIRE FOR ALL FEEDERS AND BRANCH CIRCUITS, EXCEPT TYPE MC CABLE IS ACCEPTABLE FOR FINAL VERTICAL DROPS TO RECEPTACLES ONLY 7. TERMINAL LUGS FOR WIRES 6 AWG AND SMALLER: SOLDERLESS, COMPRESSION TYPE COPPER. 8. LUGS FOR WIRES 4 AWG AND LARGER: COLOR KEYED, COMPRESSION TYPE COPPER, WITH INSULATING SEALING COLLARS. SECTION 26 05 33 RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS 1. PROVIDE CONDUIT AND TUBING, SURFACE RACEWAYS, WIREWAYS, OUTLET BOXES, PULL AND JUNCTION BOXES, AND HANDHOLES PER THE CONTRACT DOCUMENTS. 2. RACEWAY AND BOXES LOCATED AS INDICATED ON DRAWINGS, AND AT OTHER LOCATIONS REQUIRED FOR SPLICES, TAPS, WIRE PULLING, EQUIPMENT CONNECTIONS, AND COMPLIANCE WITH REGULATORY REQUIREMENTS. RACEWAY AND BOXES ARE SHOWN IN APPROXIMATE LOCATIONS UNLESS DIMENSIONED. PROVIDE RACEWAY TO COMPLETE WIRING SYSTEM. 3. UNDERGROUND MORE THAN 5 FEET OUTSIDE FOUNDATION WALL: PROVIDE PVC SCHEDULE 40. PROVIDE CAST METAL BOXES OR NONMETALLIC HANDHOLE. 4. UNDERGROUND WITHIN 5 FEET FROM FOUNDATION WALL: PROVIDE RIGID STEEL CONDUIT. PROVIDE CAST METAL OR NONMETALLIC BOXES. 5. IN OR UNDER SLAB ON GRADE: PROVIDE THIN -WALL NONMETALLIC CONDUIT, PVC SCHEDULE 40. PROVIDE CAST OR NONMETALLIC METAL BOXES. 6. IN SLAB ABOVE GRADE: THICKWALL NONMETALLIC CONDUIT. PROVIDE NONMETALLIC BOXES. 7. CONCEALED DRY LOCATIONS: PROVIDE ELECTRICAL METALLIC TUBING. PROVIDE SHEET-METAL. BOXES. PROVIDE FLUSH MOUNTING OUTLET BOX IN FINISHED AREAS. PROVIDE HINGED ENCLOSURE FOR LARGE PULL BOXES. 8. EXPOSED DRY LOCATIONS: PROVIDE RIGID STEEL CONDUIT OR INTERMEDIATE METAL CONDUIT. PROVIDE SHEET -METAL BOXES. PROVIDE FLUSH MOUNTING OUTLET BOX IN FINISHED AREAS. PROVIDE HINGED ENCLOSURE FOR LARGE PULL BOXES. 9. RIGID STEEL CONDUIT: ANSI C80.1. 10. RIGID ALUMINUM CONDUIT: ANSI C80.5. 11. INTERMEDIATE METAL CONDUIT (IMC): RIGID STEEL. 12. FITTINGS AND CONDUIT BODIES: NEMA FB 1; MATERIAL TO MATCH THE CONDUIT. SECTION 26 05 34 FLOOR BOXES FOR ELECTRICAL. SYSTEMS 1. SECTION INCLUDES FLOOR BOXES; FLOOR BOX SERVICE FITTINGS; POKE THROUGH FITTINGS; AND ACCESS FLOOR BOXES. 2. ALL FLOOR BOXES TO HAVE RECESSED LIDS TO ALLOW THE FLOOR FINISH TO BE INSERTED AND LEVEL THROUGH WITH THE REST OF THE RETAIL FLOOR SURFACE. SECTION 26 05 53. IDENTIFICATION FOR ELECTRICAL SYSTEMS 1. PROVIDE THE FOLLOWING NAMEPLATES, LABELS,WIRE MARKERS, CONDUIT MARKERS AND UNDERGROUND WARNING TAPE FOR ELECTRICAL IDENTIFICATION AS FOLLOWS: 2. INSTALL IDENTIFYING DEVICES AFTER COMPLETION OF PAINTING. a. NAMEPLATE INSTALLATION: i. INSTALL NAMEPLATES FOR THE FOLLOWING: 1. PANELBOARDS. 2. SERVICE DISCONNECTS. SECTION 26 05 73 OVERCURRENT PROTECTIVE DEVICE COORDINATION STUDY 1. SECTION INCLUDES SHORT CIRCUIT AND PROTECTIVE DEVICE COORDINATION STUDY ENCOMPASSING PORTIONS OF ELECTRICAL DISTRIBUTION SYSTEM FROM NORMAL POWER SOURCE OR SOURCES UP TO AND INCLUDING BREAKERS IN SERVICE ENTRANCE SWITCHBOARD; MAIN BREAKER IN SUB - DISTRIBUTION AND MAIN BREAKER IN EACH PANELBOARD. 2. COMPLETE SHORT CIRCUIT AND PROTECTIVE DEVICE COORDINATION STUDY TO MEET REQUIREMENTS OF NFPA 70. 3. REPORT PREPARATION: a. PREPARE STUDY PRIOR TO ORDERING DISTRIBUTION EQUIPMENT TO VERIFY EQUIPMENT RATINGS REQUIRED. b. PERFORM STUDY WITH AID OF COMPUTER SOFTWARE PROGRAM. c. OBTAIN ACTUAL SETTINGS FOR LARGE MECHANICAL EQUIPMENT ITEMS TO BE INCLUDED IN THE WORK. 4. CALCULATE SHORT CIRCUIT INTERRUPTING AND, WHEN APPLICABLE, MOMENTARY DUTIES FOR ASSUMED 3 -PHASE BOLTED FAULT SHORT CIRCUIT CURRENT AND PHASE TO GROUND FAULT SHORT CIRCUIT CURRENT AT EACH OF THE FOLLOWING: a. UTILITY SUPPLY BUS. b. BRANCH CIRCUIT PANELBOARDS. c. BUSWAY. SECTION 26 09 23 LIGHTING CONTROL DEVICES 1. PROVIDE LIGHTING CONTACTORS, LIGHTING RELAYS, AND OCCUPANCY SENSORS FOR A COMPLETE AND FULLY OPERATIONAL SYSTEM. ALL DEVICES TO BE WHITE IN. FINISH. 2. WHERE INDICATED ON DRAWINGS OR REQUIRED BY APPLICABLE CODE, PROVIDE AUTOMATIC SHUTOFF FOR LIGHTING INSIDE BUILDING LARGER THAN 5000 SQUARE FEET (465 SQUARE METERS). CONTROL SHUTOFF BY METHOD CONFORMING TO ICC IECC. SECTION 26 2416 PANELBOARDS 1. MOLDED CASE CIRCUIT BREAKERS: NEMA AB 1, BOLT -ON TYPE THERMAL MAGNETIC TRIP CIRCUIT BREAKERS, WITH COMMON TRIP HANDLE FOR ALL POLES, LISTED AS TYPE SWD FOR LIGHTING CIRCUITS, TYPE HACR FOR AIR CONDITIONING EQUIPMENT CIRCUITS, CLASS A GROUND FAULT INTERRUPTER CIRCUIT BREAKERS AS INDICATED ON DRAWINGS. DO NOT USE TANDEM CIRCUIT BREAKERS. SECTION 26 27 26 WIRING DEVICES 1. SECTION INCLUDES WALL SWITCHES; WALL DIMMERS; RECEPTACLES; DEVICE PLATES AND DECORATIVE BOX COVERS. 2. PRODUCT DESCRIPTION: NEMA WD 1, GENERAL -DUTY GENERAL USE RECEPTACLE. 3. DEVICE BODY: WHITE PER ARCHITECTS SELECTION IN THERMOPLASTIC. 4. CONVENIENCE RECEPTACLE: TYPE 5 -20 AS NOTED ON DRAWINGS 5. GFCI RECEPTACLE: CONVENIENCE RECEPTACLE WITH INTEGRAL GROUND FAULT CIRCUIT INTERRUPTER TO MEET REGULATORY REQUIREMENTS. SECTION 26 2813 FUSES 1. SECTION INCLUDES FUSES AND SPARE FUSE CABINET. 2. SELECT FUSES TO PROVIDE APPROPRIATE LEVELS OF SHORT CIRCUIT AND OVERCURRENT PROTECTION FOR THE FOLLOWING COMPONENTS: WIRE, CABLE, BUS STRUCTURES, AND OTHER EQUIPMENT. DESIGN SYSTEM TO MAINTAIN COMPONENT DAMAGE WITHIN ACCEPTABLE LEVELS DURING FAULTS. 3. SELECT FUSES TO COORDINATE WITH TIME CURRENT CHARACTERISTICS OF OTHER OVERCURRENT PROTECTIVE ELEMENTS, INCLUDING OTHER FUSES, CIRCUIT BREAKERS, AND PROTECTIVE RELAYS. DESIGN SYSTEM TO MAINTAIN OPERATION OF DEVICE CLOSEST TO FAULT OPERATES. 4. MOTOR LOAD FEEDER SWITCHES: CLASS RK1 (TIME DELAY). SECTION 26 2819 ENCLOSED SWITCHES 1. SECTION INCLUDES FUSIBLE AND NONFUSIBLE SWITCHES. 2. MANUFACTURER: COMPANY SPECIALIZING IN MANUFACTURING PRODUCTS SPECIFIED IN THIS SECTION WITH MINIMUM THREE YEARS EXPERIENCE. 3. PRODUCT DESCRIPTION: NEMA KS 1, TYPE GD WITH EXTERNALLY OPERABLE HANDLE INTERLOCKED TO PREVENT OPENING FRONT COVER WITH SWITCH IN ON POSITION, ENCLOSED LOAD INTERRUPTER KNIFE SWITCH. HANDLE LOCKABLE IN OFF POSITION. 4. FUSE CLIPS: DESIGNED TO ACCOMMODATE NEMA FU 1, CLASS R FUSES. 5. ENCLOSURE: NEMA KS 1, TO MEET CONDITIONS. FABRICATE ENCLOSURE FROM [STEEL FINISHED WITH MANUFACTURER'S STANDARD GRAY ENAMEL. a.INTERIOR DRY LOCATIONS: TYPE 1. b. EXTERIOR LOCATIONS: TYPE [3R] [4]. 6. SWITCH RATING: HORSEPOWER RATED FOR AC OR DC AS INDICATED ON DRAWINGS. 7. SHORT CIRCUIT CURRENT RATING: UL LISTED FOR 10,000 RMS SYMMETRICAL AMPERES WHEN USED WITH OR PROTECTED BY CLASS H OR K FUSES (30 -600 AMPERE). SECTION 26 5100 INTERIOR LIGHTING 1. SECTION INCLUDES INTERIOR LUMINAIRES, LAMPS, BALLASTS, AND ACCESSORIES. 2. PRODUCT DESCRIPTION: COMPLETE INTERIOR LUMINAIRE ASSEMBLIES, WITH FEATURES, OPTIONS, AND ACCESSORIES AS SCHEDULED. 3. BALLASTS a. STANDARD FLUORESCENT: ELECTRONIC BALLAST, INSTANT START, LESS THAN 10 PERCENT THD, SUITABLE FOR LAMPS SPECIFIED, WITH VOLTAGE TO MATCH LUMINAIRE VOLTAGE. b. CONTROL UNIT: LINEAR SLIDE TYPE, RATED 1000 WATTS AT 120 VOLTS. c. BALLAST: SELECTED BY DIMMING SYSTEM MANUFACTURER AS SUITABLE FOR OPERATION WITH CONTROL UNIT AND SUITABLE FOR LAMP TYPE AND QUANTITY SPECIFIED FOR LUMINAIRE. d.LAMPS: HIGH CRI, LOW MERCURY, T -5, T5H0 AND T8 AS INDICATED IN THE FIXTURE SCHEDULE. SECTION 28 31 00 FIRE ALARM SYSTEM 1. SECTION INCLUDES FA STROBES AND HORN/STROBES. 2. NEW FA DEVICES SERVING NEW TENANT SPACE TO BE TIED INTO THE EXISTING BUILDING FA SYSTEM. VERIFY THE MANUFACTURER WITH THE BUILDING LANDLORD. 3. NOTIFICATION DEVICES: a. HORN: ELECTRIC - VIBRATING POLARIZED TYPE, 24-V DC, WITH PROVISION FOR HOUSING THE OPERATING MECHANISM BEHIND A GRILLE. HORNS PRODUCE A SOUND- PRESSURE LEVEL OF 96DB, MEASURED 10 FEET FROM THE HORN. b. VISABLE ALARM DEVICES: XENON STROBE LIGHTS LISTED UNDER UL 1971 WITH CLEAR LENS. THE WORD "FIRE" IS ENGRAVED IN MINIMUM 1" HIGH LETTERS. FLASH RATE SHALL NOT EXCEED TWO FLASHES PER SECOND NOR BE LESS THAN ONE FLASH PER SECOND. SHALL BE SUIETABLE FOR INSTALLATION IN A SINGLE GANG OUTLET AND SHOULD BE WHITE IN ALL FINISHED AREAS. END OF SECTION REVIEWLL) .run COMPLIANCE WITH NFPA 70 - NEC 2 3 2011 City of Tukwila BUILDING DIVISION �LI1�06s7 SABA _ rch itects 1124 Eastlake Ave East Suite 201 Seattle, WA 98109 Q 206 957 6400 Q 206 957 6404 RUSHING Engineering -- Essentials- Delivery 1725 WESTLAKE AVE N SUITE 300 SEATTLE, WA 98109 P: (206) 285 -7100 F: (206) 285 -7111 PERMIT SET 7.19.2011 PANDORA` cITYRNKIu► JUL 20 2011 PERMIT CENTER WESTFIELD SOUTHCENTER STOREFRONT 588 TUKWILA, WA ELECTRICAL OUTLINE SPECIFICATIONS SCALE: DRAWN: CHECKED: PROJECT NO: 10008.03 E3.00