HomeMy WebLinkAboutPermit EL11-0673 - CORELINK DATA CENTERCORELINK DATA CENTER 3311 S 120 PL EL1 1 -0673 City olkukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.TukwilaWA.gov Parcel No.: 1023049069 Address: 3311 S 120 PL TUKW Project Name: CORELINK DATA CENTER ELECTRICAL PERMIT Permit Number: EL11 -0673 Issue Date: 08/29/2011 Permit Expires On: 02/25/2012 Owner: Name: SABEY CORPORATION Address: 12201 TUKWILA INTL BLVD 4THFL , SEATTLE WA Contact Person: Name: JASON PECOTTE Phone: 206 - 551 -7195 Address: 900 N 34 ST, SUITE 108 , SEATTLE WA Contractor: Name: TITAN ELECTRIC INC Address: 900 N 34 ST, SUITE 108 , SEATTLE WA Contractor License No: TITANEI963OB Phone: 206 - 633 -2811 Expiration Date: 09/02/2012 DESCRIPTION OF WORK: INSTALL AND WIRE (6) 75 KVA PDU'S Value of Electrical: NRES: $50,000.00 RES: $0.00 Type of Fire Protection: UNKNOWN Electrical service provided by: SEATTLE CITY LIGHT Permit Center Authorized Signature: Fees Collected: $1,190.63 National Electrical Code Edition: 2008 Date: (/ 6-- C I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of permit do: not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction • the •erform.. c . of work. I am authorized to sign and obtain this electrical permit. Date: Ct 2 ( ) / Signature: Print Name: JT�SJ�.1c�TTI� This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/10 EL 11 -0673 Printed: 08 -29 -2011 PERMIT CONDITIONS • Permit No. EL11 -0673 * *ELECTRICAL ** 1: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 2: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 3: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 4: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 5: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 6: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. doc: EL -4/10 EL11 -0673 Printed: 08 -29 -2011 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 tittp://Www.ci.tukwila.wa.us Electrical Permit No. t/-11- Q & 73 Project No. - (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: c . /Z0114 eLLE Tenant Name: E.L.I 1)41 -A C TF&. King Co Assessor's Tax No.: Suite Number: Floor: New Tenant: ❑ Yes ❑ .. No Property Owners Name: Mailing Address: City State Zip CONTACT PERSON - Who do we contact when your permit is ready to bp issued Name: JASON FEZ 6TIE_ Mailing Address: 'lap N g —1114 ST. Sl)1 T"E /tB E -Mail Address:jA`SON 'P �T ITAIJELE.LTEAC. f.1 Day Telephone: f060 • 55- 1 ' 9'11C SEA CTLE- bvA 18iOS City State Zip Fax Number: '.O(. - 2128 ELECTRICAL CONTRACTOR INFORMATION Company Name: -17-1-. 41.1 Et-EC-T E.1e— %Ne.. Mailing Address: 1O0 /4 Viral 'ST. 5U1TE. \A q$iO3 Contact Person: jAS154 City State Zip Day Telephone: 2.66, •ass• 2_8 I E -Mail Address: 3466 NIP 111- 4tJEC.EGTILI e-• 1.1 E-rr Fax Number: 2.teo• S'74/•2.1Z4g- Contractor Registration Number: '771-2431EI1CO2/O13 Expiration Date: q • Z,.• IZ Valuation of Project (contractor's bid price): $ SOt 000 Scope of Work (please provide detailed information): .TNISTA, t,1._ -4 WIQ_s (( -7S -JA POul Will service be altered? ❑ Yes [_No Adding more than 50 amps? Yes ❑ No Type of Use: Type of work: ❑ New ❑ Addition ❑ Service Change ❑ Remodel Tenant Improvement ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service Property Served by: ❑ Puget Sound Energy [Seattle City Light HMpplications\Forms- Applications On Line \4-2007 - Electrical Permit Application.doc bh Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $140.00 (including an attached garage) ❑ Garages, pools, spas and outbuildings $75.00 ea ❑ Low voltage systems (alarm, furnace thermostat) $55.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $75.00 (no added /altered circuits) ❑ Service change with added/altered circuits $75.00 number of added circuits $10.00 ea ❑ Circuits added /altered without service change $50.00 (up to 5 circuits) ❑ Circuits added /altered without service change $50.00 (6 or more circuits) $7.00 ea ❑ Meter /mast repair $65.00 ❑ Low voltage systems $55.00 (alarm, furnace thermostat) MULTI- FAMILY AND COMMERCIAL Fees are based on the valuation'of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $58.00 ❑ Temporary service (generator) $75.00 ❑ Manufactured /mobile home service $80.00 . (excluding garage orbutbuilding) ❑ Carnivals $75.00 Number of concessions $10.00 ea PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: Print Name: .fJ (jsBpZNe— Mailing Address: 4100 AI giqr1 Jr . SU ITS /ti Date: Day Telephone: VIA • t^c 3 3 • ZS 11 City 11/A ?8/ °3 State Zip Date Application Accepted: d )) ` t1 1 Date Application Expires: Staff Initials: l: i,/J H:Wpplications\Forms- Applications On Unee4 -2007 - Electrical Permit Application.doc hh Page 2 of 2 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http://www.TukwilaWA.gov Parcel No.: 1023049069 Address: 3311 S 120 PL TUKW Suite No: Applicant: CORELINK DATA CENTER RECEIPT Permit Number: EL11 -0673 Status: APPROVED Applied Date: 07/22/2011 Issue Date: Receipt No.: R11 -01882 Initials: WER User ID: 1655 Payment Amount: $1,003.63 Payment Date: 08/29/2011 08:14 AM Balance: $0.00 Payee: TITAN ELECTRIC INC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 12060 1,003.63 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR ELECTRICAL PLAN - NONRES 000.322.101.00.00 952.50 000.345.832.00.00 51.13 Total: $1,003.63 doc: Receiot -06 Printed: 08 -29 -2011 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: / /www.TukwilaWA.gov Parcel No.: 1023049069 Address: 3311 S 120 PL TUKW Suite No: Applicant: CORELINK DATA CENTER RECEIPT Permit Number: EL11 -0673 Status: PENDING Applied Date: 07/22/2011 Issue Date: Receipt No.: R11 -01555 Payment Amount: $187.00 Initials: WER Payment Date: 07/22/2011 02:18 PM User ID: 1655 Balance: $1,003.63 Payee: TITAN ELECTRIC INC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 11946 187.00 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES 000.345.832.00.00 187.00 Total: $187.00 doc: Receiot -06 Printed: 07 -22 -2011 Z INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -36 Permit Inspection Request Line (206) 431 -2451 R' Project: eye +4 Type of Inspection: A) 0 ` Address: 5iti _S- acilt. Date Called: Special Instructions: Date Wanted:. 47/221 623n p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. I COMMENTS: . 11.6a RluJ,DE9 o K Inspector: %/1Date: ilir h i ri REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD • . • f Retain a copy with permit . 'INSPECTION NO • PERMIT NO. 601-00 CITY OF' TUKWILA BUILDING DIVISION 6300 Southcenter. Blvd:., #100, Tukwila. WA 98188 a ▪ (206) 431 -36 • Permit Inspection Request Line (206) 431 -2451 t�. r. . • • • • Project: ! 4-114 Type of Inspection: iaa Address: ' 311......5 /20/1 Date Called: �a�rr Special Instructions: • . . • Date Wanted: .7/9 � s P.m. Requester: Phone No: . LJ Approved per applicable codes. Corrections required prior to approval. COMMENTS: /94Grze f'ix/% eg 1 . 4 “ 4 4 c , (uox bc-b S Aocc.4 r O f)&autne- t '4 , mac. i— Qa4 0 (Inspector: Date: Or/30/1 1 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. • FILE COPY Permit No., tjLh00Q(�73 PIS^ review approval is subject to errors and omissions. of construction documents does not authorize .:oltion of any adopted code or ordinance. Receipt o' proveo ► ' Copy ;, is acknowledged: By Date: City Of Tukwila BUILDING DIVISION SEPARATE PERMIT REQUIRED FOR ertiechanical ❑ Electrical rjpmbing as Piping :v of Tukwila DIVISION • SWITCN804RD 510 (3000. 4809/2770. 30. 48. 65KAIC W1 - YAM SWITCHBOARD (4180/2400. 20004 r yWrc l- l-GEN / 220. tA -Y A Y 1 L 2708. 4100V GENERATOR - GENERATOR ION. 415W 0010 - 0610180001 SV10B00 (4180. 20004 akT iA .15 i1,15 T2WIA 2500kVA 0189 41805, 4009/2774 SECONDARY 2000AF 2tID 6T §11 T es eS es 8 8 REVISIONS I'!o changes shall be made to the scope of work without prior approval of Tukwila Building Division. ; v lions will require a new plan submittal cnd may include additional plan review fees. -1 3-1/21 - 3/500 901 01 & 1/1/0 CU OND r �, uPU-il r L____JL_J LLJ__JL_ r FUTURE 005 M00I11ES 01 • /2 J 4t - 3 5E15 135001 1/250 090I Cu e GND- U1S0 2500. 480 B00/3 3-1/21 - 31500 001 01 t 111/0 CU CNO- 000/3 003/3 STARE : • TIN Consulting Electrical Engineers 1 PANEL SCHEDULE 1 11 1an.4A4.1 R gq ... .0.0 " •"RMARRA2ARASV 3i A is 18 1 3m k m 4.4.4 g R R A ARJ ,R' ,� r /,1 -141 (1 4141 'I I I I I I I I 'I 71 (I (I (I 1 AIR R R R R R 11 101 II& L A A .1 A A A g i 1 1 sae IN gg -,-"'- PANEL SCHEDULE 1 % R' gii«.000 ^•''RPARAAAMRR37 ii 14 `3J haw g p p p p ; ; $ t $ i i i i i aaaaeaeaaae E A A A AA A R R A ARJ ,R' ,� r /,1 ' 11 11 101 II& 3 '1 '1'1 'I '1 1 '1 �1 l l '1 '1 '1 ', (, (, (1 (1 (1 (1 P12 A A A A A R g A A A A A A A 1 A T ;1111E1 % ease gg -...,,-0 "r1- O'aRRnRAA: PANEL SCHEDULE a g i i R 1 El Xg «.00 "1f °ORA,gARAxAR3: A x 11 i 1 4 s g p p p p ; ; $ t $ i i i i i aaaaeaeaaae E 0n A 0n A A 052 R R R R �1 1{1 1 1 1 (1 1 1 (i (1�e��- (1 �1� ' 11 �(1 -{(I (14F �1{1 (7(e ( '1 l '1 `I �I 'Ir '1 'I c c (.(1 AIR A RR 2 2 2 2 2 g 1 g A A A A A A A A A i UMW Iggi 1E gg ------- "*-A AAR ARA AM; PANEL SCHEDULE vi q B9 «•ems .V.- .RnzAAR Ax AR 0 11 1 9 1111111111111121111N1 51 a ( 1( 1(( 1eeee(1e(1e(1(1e(1(1(1(jc (j 14 0 118 IN Pi (1(1 f(1(1(1e e(1e (I f (1(I(1 (Ie e(I(1(1 `1(,(, (, (1 (, (1 (I (, (I (I (1 (, (1 (1 (1 (, ( ( (1 (, (, Pi a li (1 (I (1 (1 (� (I (� (� (I (1 (1 (1 (1 (I (1 1 (1 (I��(,1�(1 (1 (1 (i 1 rtrt & &vtrt rf rt 2 a rt 89 -.n 0 - .,,.0- aRFRxRAFA: PANEL SCHEDULE 208Y/12O VOLTS 3 PHASE 4 WI 225 AYP .nA WAIN FEED —ORU LUGS g¢ «•e0 ^• "RAARRRAAANS. si 0 EE 0 1 9 eaeeeeeeaeeaeeeaeeaaa 51 a 22211221111NNINNINM 14 ifl R Pi (1(1 f(1(1(1e e(1e (I f (1(I(1 (Ie e(I(1(1 `1(,(, 11 ��jj L SC li (1 (I (1 (1 (� (I (� (� (I (1 (1 (1 (1 (I (1 1 (1 (I��(,1�(1 (1 (1 (i (, (I (,(,(I(,(1(11 (1 (1�(, (,(, (, (,(,(,(,(, (I` (,(1(1 (, (1( (1(I (rT' ATI( Pi a 111 y 10 112A12121111g1lIgNIINg - •101.0 . aRARggRRA' PANEL SCHEDULE . B2..00 "'• gmIARARxAA3: ii A 9 eaaaaaaaaeeeeeeeeee ae 51 22211221111NNINNINM 111 118 ifl R (1 (1 (1� 'I (1 (1 (1(1(1(1 1(1 of L li (1 (I (1 (1 (� (I (� (� (I (1 (1 (1 (1 (I (1 1 (1 (I��(,1�(1 (1 (1 (i g 3 (, (1( (1(I (rT' ATI( Pi a 1 y lIgg22121N211g1g1IIINg r=4 °-' N � ^a �- I-, N < < W " p E UQU MH PANEL SCHEDULE 206Y/120 MOLTS 3 PHASE 4 WIRE 225 AP orRh MAN LUGS gQ ft.04 ... ° °RAR19RAxRR3. t 1 eaaaaaaaaeeeeeeeeee ae a of P(1(((e((`(/ ((�(1((I (1P(1(If (' 111 118 H WBER LOrATKN: GOREUNK 383 SERVING: DATA RACKS (1 (1 (1� 'I (1 (1 (1(1(1(1 1(1 of L g 3 && of &rtutaa Esaa2vs rt PANEL SCHEDULE 208Y/120 VOLTS 3 PHASE 4 WE 225 MP NA YAN LUGS gQ ft.04 ... ° °RAR19RAxRR3. V i R 1. 11 eaaaaaaaaeeeeeeeeee ae a Pi c( 1( Ic ec(1e(Ic(I(I(1(I(1ee(Ie(I(1 111 118 (1(1(1(1( 1(((1(1(,(1(1(,(1(1(1(1(1(1(1(1 Pi L & 91 °N °N a °u{81°iA aNArt IN PANEL SCHEDULES LU O �p �� ®® N 0 LU 41° P WY* PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL11 -0673 DATE: 07 -22 -11 PROJECT NAME: CORELINK DATA CENTER SITE ADDRESS: 3311 S 120 PL X Original Plan Submittal Response to Correction Letter # Revision # Response to Incomplete Letter # After Permit Issued DEPARTMENTS: cNa 441.4 Building Division M. Fire Prevention Public Works ❑ Structural n Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 07 -26 -11 Complete Incomplete ❑ Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved 1-1 Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: DUE DATE: 08-23-11 Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 Contractors or Tradespeople Prater Friendly Page • Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company TITAN ELECTRIC INC 2066332811 900 N 34Th Ste 108 Seattle WA 98103 King Corporation UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 602250925 Active TITANEI9630B Electrical Contractor 9/2/2004 9/2/2012 General Unused Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status TITANE'986Q5 TITAN ELECTRIC Electrical Contractor General Unused 11/25/2002 11/25/2004 Expired Electrical Administrator INFORMATION • License CROOKT'011 PB Name CROOK, TRAVIS Status Active Business Owner Information Name Role Effective Date Expiration Date FUNG, LAWRENCE H Agent 09/02/2004 Bond Amount BURKE, PATRICK D President 09/02/2004 9808431 FUNG, LAWRENCE H Secretary 09/02/2004 ELECTRICAL CITATION CROOK, TRAVIS J Vice President 09/02/2004 COLONIAL AM CAS & SURETY OF MD Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 2 Lexon Ins Co 9808431 08/03/2011 Until Cancelled 19.28.101 RCW ELECTRICAL CITATION $4,000.0008/08/2011 $250.00 1 COLONIAL AM CAS & SURETY OF MD LPM4066933 08/03/2004 Until Cancelled 08/03/2011 $4,000.0008/10/2004 Assignment of Savings Information No records found for the previous 6 year period Insurance Information No records found for the previous 6 year period Summons /Complaint Information Summons and Complaints are not filed with the department for this contractor type Warrant Information Warrants are not filed with the department for this contractor type Infractions /Citations Information Infraction / Citation Date RCW Code Type Status Violation Amount EREEB00416 8/10/2009 19.28.101 RCW ELECTRICAL CITATION Satisfied $1,000.00 EREEB00206 2/20/2009 19.28.101 RCW ELECTRICAL CITATION Satisfied $250.00 ECHAE00321 8/25/2008 19.28.101 RCW ELECTRICAL CITATION Satisfied $250.00 https: // fortress .wa.gov /lni/bbip /Print.aspx 08/29/2011