HomeMy WebLinkAboutPermit EL11-0703 - WESTFIELD SOUTHCENTER MALL - JIMMY JOHN'SJIMMY JOHN'S 728 SOTJTHCENTER MALL EL1 1 -0703 City olTukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: httn: / /www.TukwilaWA.gov Parcel No.: 9202470010 Address: 728 SOUTHCENTER MALL TUKW Project Name: JIMMY JOHN'S ELECTRICAL PERMIT Permit Number: EL11 -0703 Issue Date: 08/19/2011 Permit Expires On: 02/15/2012 Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA Contact Person: Name: MITCH HART Address: 234 5 AV S , EDMONDS WA Contractor: Name: R -C TRUE LINE CORPORATION Address: 15321 105 AV CT E , PUYALLUP WA Contractor License No: RCTRULC038QG Phone: 425 - 774 -4185 Phone: 253 845 -8775 Expiration Date: 11/07/2011 DESCRIPTION OF WORK: EXISTING ELECTRICAL PANEL TO REMAIN. NEW CIRCUITS FOR FOOD SERVICE EQUIPMENT. NEW LIGHTING. Value of Electrical: NRES: $15,000.00 Fees Collected: $438.13 RES: $0.00 Type of Fire Protection: UNKNOWN Electrical service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: National Electrical Code Edition: 2008 iajl- Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this electrical permit. Signature: Date: O / �f // / Print Name: ✓S e:_j a�- This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/10 EL1 1-0703 Printed: 08 -19 -2011 • PERMIT CONDITIONS Permit No. EL 11 -0703 * *ELECTRICAL ** 1: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 2: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 3: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 4: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 5: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 6: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. doc: EL -4/10 EL11 -0703 Printed: 08 -19 -2011 a CITY OF TUKL4 A Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.dov Electrical Permit No. EL` 0 70 3 Project No. (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: 728 Southcenter Mall Tenant Name: Jimmy John's King Co Assessor's Tax No.: Suite Number: 1480 Floor: 1 New Tenant: I Yes ❑ ..No Property Owners Name: Sandwich LLC Mailing Address: 111 E. Jefferson Ave. Ste. 1N Naperville IL 60540 City State Zip CONTACT PERSON — Who do we contact when your permit is ready to be issued Name: Mitch Hart - Wilcox Construction Mailing Address: 234 5th Ave. S. Day Telephone: (425) 774 4185 Edmonds WA 98020 E -Mail Address: mhart@wilcoxconstruction.com City State Fax Number: (425) 774 -4187 Zip ELECTRICAL CONTRACTOR INFORMATION Company Name: Mailing Address: T.B.D. Contact Person: E -Mail Address: Contractor Registration Number: City Day Telephone: Fax Number: Expiration Date: State Zip Valuation of Project (contractor's bid price): $ 15,000 Scope of Work (please provide detailed information): Existing electrical panel to remain. New circuits for food service equipment. New lighting. Will service be altered? ❑ Yes m No Adding more than 50 amps? ❑ Yes VI No Type of Use: Restaurant Type of work: ❑ New ❑ Addition ❑ Low Voltage ❑ Generator Property Served by: m Puget Sound Energy ❑ Seattle City Light ❑ Service Change ❑ Fire Alarm HAApplicanons\Forms- Applications on Line \2010 Apphcation0-2010 - Electncal Permit Application doc bh Page I of 2 ❑ Remodel VI Tenant Improvement ❑ Telecommunication ❑ Temporary Service RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings ........... ............ ..$152.85 (including an attached garage) ❑ Garages, pools, spas and outbuildings .. $81.90 ea ❑ Low voltage systems (alarm, furnace them2ostat) ... $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $81.90 (no added/altered circuits) ❑ Service change with added/altered circuits $81.90 number of added circuits $11.55 ca ❑ Circuits added/altered without service change $54.60 (up to 5 circuits) ❑ Circuits added/altered without service change $54.60 (6 or more circuits) $7.65 ea ❑ Meter /mast repair $68.25 ❑ Low voltage systems $59.85 (alarm, furnace thermostat) MULTI- FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $63.00 ❑ Temporary service (generator) $78.75 ❑ Manufactured /mobile hone service $84.00 (excluding garage or outbuilding) ❑ Carnivals $78.75 Number of concessions 510.50 ea PERMIT APPLICATION NOTES - Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 clays following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: y Print Name: Date: '7A2/ 1 Day Telephone: ?/‘:,2-.S71.- D, cdS Mailing Address: /// f . ;if/r ,C'J=n/ .45 ->TF_ /Ai Pf/� ✓i LL City �c_ State G, 5/o lDate Application Accepted: 1./)4_ ` Date Application Expires: Staff Initials: ie 1 n:V■ppticnlions\l'onna- Applications On I.inet2010 ApplicxuonsV -tout 19ee ".'l Permit Applicetinn.doe bh Page 2 of 2 • 0 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.ov RECEIPT Parcel No.: 9202470010 Permit Number: EL11 -0703 Address: 728 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 07/29/2011 Applicant: JIMMY JOHN'S Issue Date: Receipt No.: R11 -01805 Initials: User ID: Payee: WER 1655 Payment Amount: $350.50 Payment Date: 08/19/2011 09:03 AM Balance: $0.00 ANDREW SHARPE TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 06875C ACCOUNT ITEM LIST: Description 350.50 Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.00 350.50 Total: $350.50 doc: Receiot -06 Printed: 08 -19 -2011 • r i"--- wqs City of Tukwila .3 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -43 1 -3670 Fax: 206-431-3665 Web site: http: / /www.TukwilaWA.gov RECEIPT Parcel No.: 9202470010 Permit Number: EL11 -0703 Address: 728 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 07/29/2011 Applicant: JIMMY JOHN'S Issue Date: Receipt No.: R11 -01621 Initials: WER User ID: 1655 Payment Amount: $87.63 Payment Date: 07/29/2011 02:45 PM Balance: $350.50 Payee: CHIPMAN DESIGN ARCHITECTURE TRANSACTION LIST: Type Method Descriptio Amount Payment Check 22552 87.63 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES 000.345.832.00.00 87.63 Total: $87.63 doc: Receipt -06 Printed: 07 -29 -2011 • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL11 -0703 DATE: 07 -29 -11 PROJECT NAME: JIMMY JOHN'S SITE ADDRESS: 728 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS. \ M�J ing Division Public Works Fire Prevention Structural Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: tx Incomplete DUE DATE: 08-02-11 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route I x I Structural Review Required n No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Notation: Approved with Conditions DUE DATE: 08-30-11 Not Approved (attach comments) REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 r • : r. • F• 2 • F• • • INSPECTION RECORD Retain a copy with permit 'INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION • 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3 • Permit Inspection Request Line (206) 431-2451 041-070 Address: 5pecial, Instructions: Type of Inspection: 4/00 10Pproved per applicable codes. COMMENTS: Date Called: Date Wanted: . Requester: Phone No: OCorrections required prior to approval. #s) Inspector: Date: iD/2-4/1/ REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. • INSPECTION NO. INSPECTION RECORD j tie -0703 / ,f Retain a copy with permit d� + PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -36 Permit Irispecti� Request Line (206) 431 -2451 Project: j �� li Type of Inspection: A493 Address: mr P Date Called: i Special .Instructions: Date Wanted:. m. /oU 6%', Requester: Phone No: IAApproved per applicable codes. D Corrections required prior to approval. COMMENTS: cefull coki\ � ioU4 u rni Coy%i,eil Jot: 60Ab ubr To Ali uh nspector: Date: 1'r /o REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be . paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit Sul -a103 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: • j0--- 11 / r L-WAI5 Type of Inspection: X403 Address: t � tint/ Date Called: Special Instr - Lions: • ' Date Wanted:. % m Requester: j Phone No: ' Approved per applicable codes. aCorrections required prior to approval. COMMENTS: v t.�nuh SID SoFftrs 04.6142 Iritpector: I r /1 rW1j Date: CV,/ • ❑ REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. , • • , • INSPECTION RECORD Retain a copy with permit 61(*) ' INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter BIvd., #100, Tukwila. WA 98188 .„ (206) 431-36 Perrnit Inspection Request Line (206) 431-2451 • peo,ect:Li . frinilotoi3 Type of Inspection: 700/ Ad d Fels: Izy rotte, Date Called: .---. Special Instructions: • • • Date Wanted:. 1 m. . . Requester: Phone No: Approved.per applicable codes. El Corrections required prior to approval. COMMENTS: COPJtJ1To ruid\ Inspector: rate: 01 bo • Fl:REINSPECTION FEE REQUIR D. Prior to next inspection. fee must be 11 paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. ..111.•■• Contractors or Tradespeople Prer Friendly Page • IP Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company R -C TRUE LINE CORPORATION 2538458875 15321 105Th Ave Ct E Puyallup WA 98374 Pierce Corporation UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 601828382 Active RCTRULC038QG Electrical Contractor 11/7/1997 11/7/2011 General Unused Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status TRUEL "'035KH TRUE LINE Electrical Contractor General Unused 5/8/1997 5/8/1999 Archived Master Electrician INFORMATION License RAU'RRH967C3 Name RAU, ROBERT H Status Active Business Owner Information Name Role Effective Date Expiration Date RAU, ROBERT H Violation Amount 01/01/1980 8/10/2009 RAU, CARLOTTA ELECTRICAL CITATION 01/01/1980 $250.00 RAU, ROBERT H Agent 01/01/1980 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 DEVELOPERS SURETY & INDEM CO 445594C 11/01/1997 Until Cancelled $4,000.00 06/15/2001 Assignment of Savings Information No records found for the previous 6 year period Insurance Information No records found for the previous 6 year period Summons /Complaint Information Summons and Complaints are not filed with the department for this contractor type Warrant Information Warrants are not filed with the department for this contractor type Infractions /Citations Information Infraction / Citation Date RCW Code Type Status Violation Amount EREEB00414 8/10/2009 19.28.161 RCW ELECTRICAL CITATION Satisfied $250.00 https: // fortress .wa.gov /lni/bbip/Print.aspx 08/19/2011 EQUIPMENT POWER SCHEDULE co PH REC LTG EQP 1. ELECTRICAL CONTRACTOR SHALL VERIFY THE EXACT LOCATION, HEIGHT AND ELECTRICAL CHARACTERISTICS OF ALL . EQUIPMENT PRIOR TO ROUGH -IN WITH KITCHEN EQUIPMENT SUPPLIER, AND KITCHEN ROUGH -IN DRAWINGS. 2. ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL AU. REQUIRED LOCAL DISCONNECTS AND SPECIAL ENCLOSURES (LE., NEMA 3R, STAINLESS STEEL, ETC.) PER LOCAL CODE. 3. ELECTRICAL CONTRACTOR SHALL CHECK ROTATION OF ALL THREE PHASE MOTORS AND CORRECT ROTATION F REVERSED. 4. ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL CIRCUIT BREAKER LOCK -ON DEVICES FOR ALL BRANCH CIRCUITS SERVING REFRIGERATION EQUIPMENT. 5. ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL FINAL EQUIPMENT POWER AND CONTROL TERMINATIONS. 6. ELECTRICAL COMPONENTS FURNISHED LOOSE BY KITCHEN EQUIPMENT SUPPUER (OR BY THE ELECTRICAL CONTRACTOR . AS NOTED) SHALL BE MOUNTED AND WIRED BY THE ELECTRICAL CONTRACTOR. 7. ALL FLEXIBLE CONDUIT EQUIPMENT CONNECTIONS SHALL BE "SEAL WIGHT'. TAG DESCRIPTION VOLTAGE PHASE LOAD (FIA) FROM PANEL CIRCUIT NO. WIRE & CONDUIT TYPE OF CONNECTION MOUNTING HEIGHT BREAKER REMARKS E -3 P.O.S. SYSTEM 120V/10 • 4.1A A 12 2 #12, 3/4 "C 1 X12 GRD. DUPLEX I.G. RECEPTACLE IN CASEWORK 1P, 20A LOCATE RECEPTACLE WITHIN 41 -0" OF P.O.S. STATION AND APC UPS E -8 ICE/DRINK DISPENSER 120V/10 4A • A . 26,28 2 #12, 3/4 "C DOUBLE DUPLEX RECEPTACLE 12" A.F.F. 1P, 20A LOCATE RECEPTACLE WITHIN CASEWORK E -13 REFRIGERATED PREP TABLE 120/V10 12.8A A 8 2 X12, 3/4 "C DUPLEX RECEPTACLE 12" A.F.F. 1P, 20A 0.48 __ 0.80 POWER - EXHAUST FANS EF -1, DAMPER • 20 GFI 0.80 A 10 E -15 OVEN/PROOFER 208V/30 18.4A A 2,4,6 t4 0' 3/ 60A /3P DISCONNECT +18 A,F.F . 50A UNIT REQUIRES (OUND 3 HOT, 1 NEUTRAL E -17 ICE MAKER (WATER COOLED) 208V/10 8.1A A 33,35 GRD 23/4 C. J-BOX 72" A.F.F. 21), 20A LIGHTING - DINING TRACK VIA CURRENT LIMITER 20 1 0.72 0.90 ___ LIGHTING - FOOD AREA TROFFERS, SIGN LTS 20 1 E -23 WALK -IN FREEZER COMPRESSOR 208V/10 8.8A q 1,3 3 #12, 1 012 GRD., 3/4 C. 30A /2P NF DISCONNECT VERIFY 2P, 20A INTERLOCK WITH . FREEZER EVAPORATOR. VERIFY LOCATION. WITH INSTALLER E -23a WALK-IN . COOLER COMPRESSOR 208V/10 7.ZA A 5,7 3 /12, 1 it2 GRD., 3/4 "C. 30A /2P NF DISCONNECT �' 20A INTERLOCK WITH COOLER EVAPORATOR. VERIFY LOCATION WITH INSTALLER E -23b WALK -IN FREEZER LIGHTS, EVAPORATOR, DOOR H1R. 120V/10 1.97A A 7 2 #12, 3/4 "C J-BOX VERIFY 1P, 20A PROVIDE LOCAL DISCONNECT FOR EVAPORATOR E -27. SUCER 120V/10 6.0A A 14 2 #12, 3/4 "C DUPLEX RECEPTACLE FL MOOUNOTRED 1P, 20A WALKER/WIREMOLD FLOOR MOUNTED BOX 44 r LANDLORD DISTRIBUTION SERVICE VOLTAGE: 480Y/277V 00- 00 0 0 N c c POWER RISER FLAG NOTES : EXST'G EXISTING LANDLORD DISTRIBUTION /SWITCHGEAR. NO CHANGE. EXISTING CONDUIT /FEEDER. NO CHANGE EXISTING 100A 3P FUSED DISCONNECT. NO CHANGE EXISTING 75kVA 480- 208Y/120V TRANSFORMER. NO CHANGE EXISTING 200A, 200A MAIN BREAKER, 208Y/120V, 3P4W, 42 SPACE PANELBOARD. CONFIGURE BRANCH CIRCUITS PER PANEL SCHEDULE, THIS SHEET. a TENANT PACE EXISTING PANELBOARD LOCATION: BACKROOM PANEL A LOAD DISTRIBUTION FEED FROM: LANDLORD FEEDER: 200 AMP 3P4W + GND . PH REC LTG EQP HTG KIT CKT DESCRIPTION PH AMP POLE LOAD kVA . AMP: 200 VOLTS: 208/120 PHASE: 3 WIRE: 4 BUS TYPE: CU A.I.C.: 10K M.L.O.: MAIN CB: 200 FLUSH: SURFACE: XXX GND. BAR: XXX ISO GND: 200 %NEU: FEED THRU: DEL LUG: TOP FEED: BTM FEED PANELT.C.L. LOAD (kVA) A B C A B C A B C A B C A B C A B C A B C :A ._��� B C A B C A E C A 8 C' A B C A B C A 8 C• EF -1 EXHAUST FAN 120V/10• 1/4 HP 1.24 1 3 5 7 9 11 13 • 15 17 19 21 23 25 27 29 31 33 35 37 39 41 ...•BREADOVEN/PROOFER 4 6 8 10 12 14 18 18 20 22 24 WALK IN FREEZER COMPRESSOR A 8 C A B C A B C A 0 C A 0 C A B C A B C s A:. B C A B C A B C A 8 C A B C 20 2 1.24 ____ 124 - - - 1.24 0.84 WALK IN COOLER COMPRESSOR 20 2 0.84 __ - - 0.84 0.48 - - - 0.84 WALK IN LIGHTS /DEFROST _ 20 1 0.48 __ 0.80 POWER - EXHAUST FANS EF -1, DAMPER • 20 1 0.80 020 POWER - CEILING FANS 20 1 0.20 SPARE 20 1 0,72 ___ LIGHTING - DINING TRACK VIA CURRENT LIMITER 20 1 0.72 0.90 ___ LIGHTING - FOOD AREA TROFFERS, SIGN LTS 20 1 0.90 _____ 0.38 SPARE 20 1 RECEPTACLES -SHOW WINDOWS 20 1 0.36 1.20 POWER - EXTERIOR SIGNAGE 20 1 1.20 . 1.20 _S_ _S_ POWER - EXTERIORSIGNAGE 20 1 1.20 a 0.20 1.00 RECEPTACLE - JIMMY CLOCK 20 1 0.20 ___ 0.84. RECEPTACLES - NEON SIGNS 20 1 1.00 ICE MACHINE 20 2 0.84 ____ 6.00 0,84 - • - 0.84 WATER HEATER 60 3 6.00 _ __ ____ 6.00 - - - 6.00 8.00 __ ....1.:2 2. 20 .. . ............... ..:. s50 r... 3. 6.00 ,. . .................. 2. 20 2.20 - - - 2.20 2.20 - • - 2.20 REC 2.9 LTG 5.4 EQP 18.8 HTG 14.4 KIT 18.3 1.53 REFRIGERATED PREP TABLE 20GFI 1 1.53 ____ 0.54 __a_ 0.38 ____ ____ 1.53 laigal,,j(ggafjIIIIIIIMIIIII1M 20GFI 1 1.53 RECEPTACLES - P.O.S. SYSTEM 200F1 1 0.54 0.72 SLICER 20GFI 1 0.72 RECEPTACLES - PHONE BANK 20GFI 1 0.38 TOTAL 59.8 0.18 RECEPTACLES • CONSOLE TABLES 20GFI 1 0.18 FEEDER T.C.L. LOAD (kVA) 0.54 RECEPTACLES - MAKE LIP LINE (PRINTERS) 20GFI 1 0.54 0.72 RECEPTACLES - MGR DESK 20GF1 1 0.72 0.18 ____ RECEPTACLE- LOWELLCABINET /RACK 20GFI 1 0.18 REC 2.9 LTG 6.8 EQP 18.8 HTG 14.4 KIT 18.3 _•111111111_® 26 28 30 32 34 38 38 40 42 RECEPTACLES - ICE/DRINK DISPENSER 20GFI 1 0.60 ____ 0.50 RECEPTACLES - ICE/DRINK DISPENSER 20GFI 1 0.50 0.60 REACH IN REFRIGERATOR 20GFI 1 . 0.60 SPARE 20 1 S____ SPARE 20 1 TOTAL 61.2 _____ 4.80 SPARE 20 1 FEEDER DEMAND kVA 54.8 AMPERES 152.1 VAV -1 50 3 4.80 4.80 - 4.80 - 4.80 •:•:•:•.••••:•:•:•:t A •. • •♦ •0.5 •• ••3.3 • •6.0 • •• ♦4.8 ••••••7.0, MsnuracturedType• Circuit Breaker Type: RECEPTACLES (1ST 10KVA): Remarks: 1 RECEPTACLES OVER 10KVA: • = PROVIDE BREAKER HANDLE LOCIOFF - LIGHTING: EQUIPMENT: HEATING: 1 KITCHEN: 1 25% OF LARGEST MOTOR: CONNECTED: 1 2.9 5.4 18.8 14.4 18,3 kVA kVA kVA kVA kVA kVA ' kVA kVA 100% 2.9 kVA 50% kVA 125% 8.8 - kVA 100% 18.8 kVA 100% 14.4 kVA 85% 11.9 kVA 25% kVA B 1.1 1.2 8.0 4.8 8,8 C 1.3 0.9 6.8 4.8 4.5 •T•• •- • -2,9, •• 5.4 __ _ 14.4, ••18.3 18.8 TOTAL CONNECTED LOAD PER PHASE: 59.8 DEMAND: 64.8 kVA PHASEA: 21.7 SERVICE LOAD CALCULATIONS MECHANICAL EQUIPMENT POWER SCHEDULE TAG DESCRIPTION VOLTAGE/ PHASE KW/HP/FLA REMARKS VAV -1 VAV BOX WITH 12kW HEATER 208V/30 41 FLA EXISiiNG UNIT/DISCONNECT. NO CHANGE WH -1 WATER HEATER 208V/30 50 FLA 18kW ELECTRIC HEATER EF -1 EXHAUST FAN 120V/10• 1/4 HP MECHANICAL EQUIPMENT POWER SCHEDULE NOTES: 1. ELECTRICAL CONTRACTOR SHALL REFER TO ALL MECHANICAL, PLUMBING AND ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS AND CHARACTERISTICS OF ALL EQUIPMENT LISTED BELOW. ANY MODIFICATION AND /OR ADDITIONAL WORK NECESSARY SHALL BE INCLUDED IN THE BASE BID. 2. ELECTRICAL CONTRACTOR SHALL CHECK THE ROTATION OF ALL THREE PHASE MOTORS AND CORRECT THE ROTATION IF REVERSED. 3. ALL TEMPERATURE CONTROL AND INTERLOCK WIRING SHALL BE BY HVAC CONTRACTOR UNLESS NOTED OTHERWISE. 4. ELECTRICAL CONTRACTOR SHALL SUBMIT EIGHT (8) SETS OF CATALOG CUTS FOR ALL SCHEDULED EQUIPMENT FURNISHED BY THIS CONTRACTOR FOR ARCHITECT/ENGINEER REVIEW. 5. ELECTRICAL CONTRACTOR SHALL COORDINATE THE ROUTING OF POWER WIRING TO ROOF - MOUNTED . EQUIPMENT WITH MECHANICAL PIPE CURB ASSEMBLY. NO SEPARATE ROOF PENETRATIONS WILL BE PERMITTED. 6. ELECTRICAL CONTRACTOR SHALL FURNISH AND WIRE DUCT SMOKE DETECTORS IN THE RETURN AIR PLENUM AND A FAN SHUT DOWN RELAY FOR ALL AIR SUPPLY UNITS. DETECTORS TO BE INSTALLED BY MECH. CONTR. 7. ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL A WEATHER PROOF, GROUND FAULT INTERRUPTER TYPE RECEPTACLE, AT AN ACCESSIBLE LOCATION FOR SERVICING ON ROOFTOP HEATING AND AIR CONDITIONING EQUIPMENT. THIS RECEPTACLE SHALL BE LOCATED WITHIN 25 FEET AND AT THE SAME LEVEL OF THIS EQUIPMENT. GROUND UP \ �o Uy 0 0 GROUND DOWN RECEPTACLE MOUNTED 0 37" OR LOWER RECEPTACLE MOUNTED 0 38" OR HIGHER RECEPTACLE GROUND ORIENTATION DETAIL SEPARATE REQUIRED FOR: 14 Mechanical ❑ Electrical Xi Plumbing Gas Piping City of Tukwila B III-DING DIVISION KEYED NOTES: (x) 1. STORE FRONT SIGN CONTROLLED BY TIME SWITCH LOCATED NEAR DESK IN BACK AREA. E.C. TO VERIFY LOCATION OF SIGN JUNCTION BOX AND QUANTITY OF CIRCUITS NEEDED WITH SIGN CONTRACTOR AND ARCHITECT. 2. SEE ELECTRICAL/DATA PHONE BANK DETAIL, SHEET COM1. 3. RECESSED MOUNTED RECEPTACLE FOR CLOCK. VERIFY EXACT LOCATION WITH FIELD REPRESENTATIVE BEFORE INSTALLING. 4. FLUSH MOUNTED 120V RECEPTACLE MOUNTED AT 6" ABOVE WINDOW FOR NEON SIGNS. SEE KEYNOTE 1 SHEET Al FOR HEADER /SOFFIT NOTES 5. RECEPTACLE FOR COMPONENT CABINET. SEE "NETWORK CABINET DETAIL ELEVATION ", SHEET COM1 FOR MOUNTING HEIGHT REQUIREMENTS. 6• FLUSH MOUNTED RECEPTACLE AT +128" AFF FOR NEON SIGN. GENERAL ELECTRICAL NOTES: 1. RUN WIRING TO P.O.S. AND PREPERATiON TABLES THRU WIRING CHASE PROVIDED IN THE CABINETS. CONCEAL CONDUIT RISER TO CEILING BEHIND WALL. ARRANGE CONDUIT SO DATA WIRING CAN BE DAISY CHAINED ONE OUTLET TO THE NEXT. 2. AU. 120V RECEPTACLES IN PREP AREA ARE TO BE GFI PROTECED. ANY OTHER RECEPTACLES IDENTIFIED AS GFI PROTECTED SHALL BE GFI DEVICES, OR CONNECTED TO GFI CIRCUIT BREAKER OR CONNECTED DOWNSTREAM OF AND PROTECTED BY A GFI DEVICE. 3. TELEPHONE BOARD /PUNCHDOWN BLOCK IS TO BE MOUNTED ABOVE REFRIGERATOR IN BACK PREP AREA, NOT EXPOSED TO PUBUC. 4. E.C. SHALL COORDINATE REQUIRED CONDUIT AND CONDUIT INSTALLATION LOCATIONS WITH COMMUNICA1iONS/DATA CONTRACTOR. 5, NO SURFACE MOUNTED CONDUIT ALLOWED ON WALL SURFACES IN EXPOSED AREAS. ALL CONDUIT SERVING DEVICES IN EXTERIOR WALLS MUST BE CONCEALED WITHIN THE WALLS. 6. ANY EXISTING MC CABLE WHICH WILL BE IN EXPOSED AREAS TO BE REPLACED WITH RIGID CONDUIT. • Y v v • LANDLORD REQ'D NOTES: HEVIEWEU FOR COMPLIANCE WITH NFPA70 - NEC AUG 18 2011 City of BUILDING VISION COOLER FREEZER FXLZ COPY Permit No -EU. I 'O i 0.19, Plan review approval is subiect to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy and ctions is acknowledged: By Date: / c/ / / / City Of Tukwila BUILDING DIVISION DINING A 11IIi111I DINING A STORAGE PANEL A 9,41 KITCHEN I PREP -201 �\ +601 \1\ 20 \ \ IMP 0 A -25,27 VIA TiMESWITCH A -11 LE: 1/4• = r -o° RECEIVED JUL 29 2011 Ll tL � � � PERMIT CENTEF 3 J LETTERS. MINIMUM SIZE SHALL BE ONE. (1) INCH WITH ONLY THE TENANT'S SPACE NUMBER ENGRAVED ON SUCH, PERMANENTLY AFFIXED. INSTALL A COMPLETE TYPEWRITTEN IDENTIFICATION DIRECTORY CARD OR ALL MAIN AND BRANCH CIRCUITS IN THE PANEL DOOR h REVISIONS No changes shall be made to the .Scope of work without prior approvc1 of .TUkyviia Building Division.. OT : Revisions will require a nevi plan-submit at - and may include additional plan review fees: m 0 Oft ce 1� J zz o = W 0) : c 00 Revisions ISSUE FOR JJ REVIEW 07/18/2011 A REVISION PER JIMMY LLAJOHN'S 07/26/11 REVISIDN PER LL /ISSUE ©FOR PERMIT 07/27/11 cri z -I < J 0 0 CL W< U - I� o-z ___ Q�. Cl_ ARCHITECT HEREBY CERTIFY THAT TIESE PLANS HAVE BEEN PRE- PARED UNDER NY SPERVISU1I AND 'NAT 10 THE WST OF NY *SLEDGE, SLEDGE, THE SAIE LIM1LY VIM ALL RULES, REGULATIONS AND URDDNANCES OF TUJKWILA. Vq RELATING TD STRUCTURES AND BUILDINGS, Drawn By Checked By Abossein Engineering, L.L.C. MECHANICAL- ELECTRICAL CIVIL - LEED FIRE PROTECTION 2100112TH AVE. NE BELLEVUE, WA 98004 PH: (425) 462.9441 FAX: (425) 462.9451 E -Mail: cservice @abossein,com www.abossein.com m 0 Oft ce 1� J zz o = W 0) : c 00 Revisions ISSUE FOR JJ REVIEW 07/18/2011 A REVISION PER JIMMY LLAJOHN'S 07/26/11 REVISIDN PER LL /ISSUE ©FOR PERMIT 07/27/11 cri z -I < J 0 0 CL W< U - I� o-z ___ Q�. Cl_ ARCHITECT HEREBY CERTIFY THAT TIESE PLANS HAVE BEEN PRE- PARED UNDER NY SPERVISU1I AND 'NAT 10 THE WST OF NY *SLEDGE, SLEDGE, THE SAIE LIM1LY VIM ALL RULES, REGULATIONS AND URDDNANCES OF TUJKWILA. Vq RELATING TD STRUCTURES AND BUILDINGS, Drawn By Checked By LIGHTING FIXTURE SCHEDULE NOTES: 1. ELECTRICAL CONTRACTOR SHALL SUBMIT EIGHT (8) SETS OF CATALOG CUTS FOR ARCHITECT /ENGINEER REVIEW, PRIOR TO ORDERING FIXTURES. REVIEW, PRIOR TO ORDERING FIXTURES. 2. ALL ACRYLIC LENS SHALL BE 100% VIRGIN ACRYLIC: 3. ALL FLUORESCENT LAMPS SHALL BE ENERGY SAVING TRIM UNE T8 WARM WHITE F32T8 /SP35/RS 4. ALL BALLASTS SHALL BE RAPID START ELECTRONIC ENERGY SAVING TYPE. 5. ALL EXIT SIGNS AND EMERGENCY LIGHT FIXTURES ARE TO BE STRICT ACCORDANCE WITH THE LOCAL FIRE PREVENTION CODE AUTHORITY. ANY MODIFICATIONS TO UPGRADE SYSTEM SHALL BE INCLUDED IN THE BASE BID. ALL EXIT SIGNS ARE TO BE INSTALLED IN A VISIBLE LOCATION. ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL WHERE NECESSARY TO DROP A SIGN BELOW AN OBSTRUCTION. 6. ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL THE NECESSARY CUPS, SCREWS, RIVETS, ETC., TO SECURELY FASTEN RECESSED LAY –IN UGHTING FIXTURES TO CEIUNG FRAMING GRID WORK. 7. ALL LIGHTING FIXTURES SHALL BEAR THE APPROPRIATE UL LABEL FOR THE APPUCATION AND UNION LABEL WHERE REQUIRED. 8. ALL UGHTING FIXTURES SHALL BE SHATTER PROOF OR COMPLETLEY SHIELDED /COVERED. LIGHTING FIXTURE SCHEDULE SYMBOL DESCRIPTION MOUNTING AS UGHTOUER XT2GVA24012003 3 -25 2' X 4' LAMP: (2) 32W – F32T8 /CW (57 WATT) RECESSED CEILING GRID ASE UGHTOUER XT2GVA24012003 –EM 2 -32 2' X 4' • LAMP: (2) 32W – F32T8 /CW (57 WATT) RECESSED CEIUNG GRID W/E BALLAST EMERGENCY UGHT . T – TRACK UGHTOUER – LYTESPAN 6000 MATTE BLACK C – BASIC MINI UNIVERSAL UGHTOUER #9021BK LAMP: (1) PAR 30 CFL 15W (UTETRONICS L -1372) D – UGHTOUER LYTEFLOOD COMPACT FLUORESCENT #8276EAL (2) 18W (22112) TWIN TUBE FLUORESCENT (36 WATT) E – UGHTOUER FSP501419 -MINI PENDANT WITH. CORD, ATTACHMENT FITTING & RED GLASS. LAMP: (1) A19 CFL 5W (UTETRONICS M8- 500DP) T - TRACK MOUNTED AT 1O' -6" A.F.F. (TYPICAL) C – TRACK MOUNT D – TRACK MOUNT E - TRACK PENDANT 72" A.F.F. OVER HIGH TABLES AND 60" A.F.F. OVER LOW TABLES AND BOOTHS. D F2 1-0 F2 – GOOSENECK ARM AND FIXTURE– McFADDEN LIGHTING #4417 -B2- 22.5- 3 /4 –ABO LAMP: (1) 32W CFL 32 WATTS MENU BOARD GOOSENECK- WALL MOUNTED 11' -0" A.F.F. X UGHTOUER #LLNURW – LED EXIT WITH EMERGENCY BATTERY BACK UP 3.9 WATTS SEE PLAN – MOUNT ON WALL OR CEIUNG. EX UGHTOUER #LC14NH71 RW – LED EXIT WITH EMERGENCY UGHTING HEADS BATTERY BACKUP 14.1 WATTS SEE PLAN – MOUNT ON WALL OR CEIUNG. . mill ' ei '• EM j=6 UGHTOUER118NT6W – EMERGENCY LIGHTING 2 HEAD UNIT W/ BATTERY BACKUP 9.2 WATTS SEE PLAN – MOUNT ON WALL OR CEIUNG. G UGHTOUER 1101 LED UGHTOUER #1126 REFLECTOR TRIM LAMP: LED 15 WATTS SEE PLAN – MOUNT IN SOFFIT CF HUNTER FAN COMPANY PARAMOUNT #3856 MOUNT AT 108" A.F.F. E.C. SHALL FIELD VERIFY THE LENGTH OF DOWNROD FOR CEIUNG FAN. DOWNROD SHALL EXTEND FROM CEIUNG FAN TO STRUCTURE ABOVE DOWNROD SHALL BE FLAT BLACK / / ` UGHTING FIXTURE SUPPUER: KEC CONTACT: DAN PROCTOR 301 E. MERCURY DRIVE SUITE #1 TEL: (888)356 -1640 CHAMPAIGN, IL 61822 FAX: (217)356 -1661 EMAIL danproctor®kecdesign.net NO SUBSTITUTIONS ON ANY FIXTURES. UNISTRUT TO BE MOUNTED PARALLEL TO TRACK INSTALLATION �-- THREADED ROD TRACK MOUNTED UNISTRUT 10' -6" AFF TYP DETAIL 0 HIGH TABLE (0 LOW TABLES, PENDANT HEIGHT IS 60" AFF) TYPICAL LIGHTING PLACEMENT DETAIL SCALE: NONE REFLECTED CEILING NOTES 1. REFER TO MECHANICAL FOR EXACT NUMBER, TYPE AND LOCATION OF SUPPLY, RETURN AND EXHAUST FIXTURES. 2. REFER TO ELECTRICAL FOR EXACT NUMBER, TYPE AND LOCATION OF OUTLETS. 3. G.C. WILL COORDINATE . THE WORK OF ALL TRADES INVOLVED IN THE CEILING WORK TO INSURE CLEARANCES FOR FIXTURES, DUCTS, PIPING, CEIUNG SUSPENSION SYSTEMS, ETC., NECESSARY TO MAINTAIN THE FINISHED CEILING HEIGHTS INDICATED ' ON . ARCHITECTURAL DRAWINGS. 4. PERIMETER CEILING ANGLE, WHERE OCCURS, SHALL BE INSTALLED TIGHT TO PARTITION SURFACES, FREE FROM CURVES, BREAKS OR OTHER IRREGULARITIES BY G.C. 5. PROVIDE CEILING ACCESS AS REQUIRED FOR EQUIPMENT AND SYSTEM MAINTENANCE VERIFY MANUFACTURER RECOMMENDATIONS. 6. ALL SWITCHES AND DIMMERS SHALL BE LOCATED 48" ABOVE FINISHED FLOOR, TO CENTER OF SWITCHES AND 6" FROM DOOR FRAME U.O.N. MULTIPLE SWITCHES AT ONE LOCATION SHALL BE GAINED TOGETHER AND FINISHED WITH ONE COVER PLATE. 7. ALL SPECIFIC INFORMATION CONCERNING INSTALLATION OF VARIOUS ABOVE CEIUNG ELEMENTS ARE TO BE FOUND IN THE HVAC, PLUMBING, FIRE PROTECTION, ELECTRICAL AND LIGHTING DRAWINGS. 8. CONTRACTOR TO NOTIFY ARCHITECT OF ANY CONFLICT OF LIGHT FIXTURE LOCATIONS WITH MAIN RUNNERS, DUCTS, ETC., PRIOR TO INSTALLATION. 9. FURNISH AND INSTALL UNDERWRITERS LABORATORY, INC (UL) LABELED DEVICES THROUGHOUT. 10. G.C. TO INSURE THAT EXIT SIGNS & EMERGENCY UGHTING TO MEET ADA /IBC REQUIREMENTS. 11. ANY EXPOSED CONDUIT IN DINING ROOM MUST BE METAL CONDUIT AND RUN TIGHT TO THE DECK. ONLY EXCEPTION IS MC CABLE MAY BE USED WHEN CONNECTING TRACK UGHTING TO THE JUNCTION BOX. NO MC CABLE CAN BE RUN LONGER THE 12" WHEN RUNNING HORIZONTALLY ON THE DECK TO THE JUNCTION BOX. 12. MC CABLE USED TO POWER THE TRACK UGHTING IS TO BE INSTALLED TIGHT TO THE THREADED RODS TO THE UVE END OF THE TRACK. 13. NO SURFACE MOUNTED CONDUIT ALLOWED ON WALL SURFACES IN EXPOSED AREAS. ALL CONDUIT SERVING DEVICES IN EXTERIOR WALLS MUST BE CONCEALED WITHIN THE WALLS. 14. ANY EXISTING MC CABLE WHICH WILL BE IN EXPOSED AREAS TO BE REPLACED WITH RIGID CONDUIT. 5/8" GYPSUM BOARD NUT WOOD BLOCKING /JOIST BLOCKING TO BE FIRE RATED. (2) NUTS FLAT WASHER SPRING NUT 1 -1/2" DEEP P100 UNISTRUT AY" • 3111e 3•I SAMMY 3/8" ALL– THREADED ROD SPACED HORIZONTIALLY AT 5' -0" 0.C. MAX. GHTING TRACK UNI -STRUT DETAIL #1 SCALE: NONE NOTE: UNI –STRUT IS TO STOP SHORT EXACTLY 6" FROM END OF TRACK. ALL JOINTS IN UNI –STRUT ARE TO BE SECURELY FASTENED USING HEAVY DUTY JOINING PLATES. BOTTOM OF UNI –STRUT TO BE AT 10' -6 ". SPRING NUT FLAT WASHER (2) NUTS (2) NUTS FLAT WASHER SPRING NUT 1 -1/2 DEEP P100 UNISTRUT STRUCTURAL MEMBER 1 -1/2" DEEP P1000 UNISTRUT - SP AT TOP OF BAR JOIST. NOT TO BE SECURED TO ROOF DECKING. ONLY TO BE SECURED TO UNISTRUT /STRUCTURAL MEMBERS. 3/8" ALL– THREADED ROD SPACED HORIZONTIALLY AT 5' -0" O.C. MAX. UGHTING TRACK UNI -STRUT DETAIL #2 SCALE: NONE A -17c VIA UGHTOUER #PLD720BK 720W C DINING A ±X-X" B.O. ROOF DEC PAINT PT -5 DINING A COOLER & FREEZER ■ FREEZER 6'x6' STORAGE. REFRIG. 6' x 6' 10' -6" CLNG. IL AS A -19d AS A -19d KITCHEN / PREP ASE –19 NL 1O-- CLNG. TILE C -1 7` -6" GYP. BD. S# • IT PAINT PT-4 CF A -13e LIGHTING PLAN SCALE: 1/4" = -0t.\\ °IT; REVIEWED f-OH COMPLIANCE WITH NPPA 70 - NEC AUS 18 2011 City of Tukwila BUILDING DIVISION RECEIVED 2 9 2011 PERMTCENTER Abossein Engineering, L.L.C. MECHANICAL - ELECTRICAL CIVIL - LEED FIRE PROTECTION 2100 112TH AVE, NE BELLEVUE, WA 98004 PH: (425) 462-9441 FAX: (425) 462.9451 E -Mail: cservice @abossein.com www.abossein.com co j trt Wu wA r4 Z VJ y A 41 a,� b L 0 • o re) V! o � 4..r,, .* 0 Revisions ISSUE FOR JJ.REVIEW 07/18/2011 A REVISION PER . JIMMY JOHN'S 07/26/11 REVISION PER LL /ISSUE ©FOR PERMIT 07/27/11 ARCHITECT �J Z < —1 W 0 Z 0 (f) W 0 1- I- -I X LL_ I KM CERTIFY THAT THESE PLANS HAVE TEEN PRE- PARED USER NY. SUERVISD]i AND THAT TO THE LEST IF NY KIHOVLEDfE, THE SNE COMPLY WITH ALL RUES, REGULATIONS AND ORDINANCES OF TU(VILA. Va RELATING TO STRUCTURES AND BUILDINGS, Drawn By Checked By Scale 1/4"=1'-0" Date 7/18/2011 Ibr 2101 Sheet No. E2 (OF 4) 120V Interior Lighting Summary LTG -INT 2009 Washington State Energy Code Compliance Forms for Nonresidential and M uitifamily Residential Revised December 20 Project Info Project Address JM M Y JOHNS Dafe 7/13/2011 so UTH C EN TER M ALL For Building Department Use TUKW3LAWA Applicant Name: Applicant Address: Applicant Phone: Project Description Applicability (yes, no, n.a.) ❑ New Building ❑ Addition la Alteration Plans Included Indicate controls (Sections 1513) including commissioning requirements on plans. Compliance Option Building Department Notes • Prescriptive 0 Lighting Power Allowance • Systems Analysis • Clear (See Qualification Checklist ( over). Indicate Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) changed III No changes are being made to the lightingand space use not ❑ Less than 60% of the fixtures near, installed wattage not increased, &space use not changed. Maximum Allowed Lighting Wattage Location (floor plan /room #) Occupancy Description Allowed Watts per ft2 ** Gross Interior Area in ft2 Allowed x Area Project Address RESTAURANT 1.20 560.0 672 Applicability (yes, no, n.a.) RESTAURANT -18' -0" CEII.3NG 1.43 575 822 Building Department Notes TRACK -720W CURRENT L14 3 TER 1 720.0 720 rom Table 15 -1 (over) - document all exceptions on form LTG -LPA Proposed Lighting Wattage Total Allowed Watts 1494 Location (floor plan /room #) Fixture Description . Number of Fixtures Watts/ Fixture Watts Proposed Project Address J24 M Y JOHNS Date . 7/13/2011 The following information is the 2009 Wash ington State necessaryto check a permit application fo rco mpliance with the lighting, motor, and transformer req uirements in Nonresidential Energy Code. Applicability (yes, no, n.a.) AS/ ASE - RECESSED LENSED TROFFER (2) 32W T8 - 9 57.0 513 Building Department Notes TRACK -720W CURRENT L14 3 TER 1 720.0 720 Local control /access F2 -SJ N GOOSENECK 3 32.0 96 G - RECESSED CAN 8 15.0 120 N.A. 1513.3 Daylight zone control Schedule w ith type and features, indicate locations E2 N.A vertical glazing Indicate vertical glazing on plans E2 N.A. overhead glazing Indicate overhead glazing on plans . N.A. • 1513.4 Display /exhib /special Indicate separate controls • . N.A. otal Proposed Watts may not exceed Total Allow ed Watts for Interior LIGHTING CONTROL Total Proposed Watts 1449 Lighting, 2009 Washington Motor, and Transformer Permit Plans Checklist LTG -CHK State Energy Code Compliance Forms for Nonresidential and M ultifamily Residential Revised December 2010 Project Address J24 M Y JOHNS Date . 7/13/2011 The following information is the 2009 Wash ington State necessaryto check a permit application fo rco mpliance with the lighting, motor, and transformer req uirements in Nonresidential Energy Code. Applicability (yes, no, n.a.) Code Section Component • Information Required • Location on Plans Building Department Notes LIGHTING CONTROLS (Section 1513) Yes ', 1513.1 Local control /access Schedule with type, indicate locations E2 Yes 1513.2 Area controls Maximum lint per sw itch E2 N.A. 1513.3 Daylight zone control Schedule w ith type and features, indicate locations E2 N.A vertical glazing Indicate vertical glazing on plans E2 N.A. overhead glazing Indicate overhead glazing on plans . N.A. • 1513.4 Display /exhib /special Indicate separate controls • . N.A. .1.513.5 Exterior shut -off Schedule with type and features, indicate location . N.A. (a) timer w /backup Indicate location E2.1 , El . N.A. (b) photocell. . Indicate location Yes N.A. Yes +: r, .1513.6 Inter. auto shut -off Indicate location 1513.6.1 (a) occup. sensors Schedule w ith type and locations E2 1513.6.2 (b) auto. sw itches Schedule with type and features (back -up, override capability); Indicate size of zone on plans E2.1 N.A. 1513.7 Hotel /motel controls Indicate location of room master controls Yes EXIT SIGNS •►: 1513.8 Commissioning Indicate requirements for lighting controls commissioning E2.1 (Section 1514) I• Yes '• 1514 Max. watts Indicate watts for each exit sign E2 LIGHTING POWER ALLOWANCE (Section 1530 -1532) Yes —.. 1531 Interior Lighting Sunmary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture E2.1 N A 1532 Exterior Lighting Summary Form Completed and attached. Schedule w ith fixture types, lamps, ballasts, watts per fixture . . MOTORS (Section 1511) . N.A. T. TRANSFORMERS 1511 Bec motor efficiency MECH -MOT or Equipment Schedule w ith hp, rpm, efficiency (Section 1540) N.A. 1540 Transformers Indicate size and efficiency DIAGRAM - INTERIOR /EXTERIOR CONSULT OWNER'S REPRESENTATIVE IN FIELD FOR TIME /OPERATION SCHEDULING. PROVIDE SEPERATE SURFACE MOUNT ENCLOSURES FOR CONTACTORS. SIZE PER NEC. TIMER POWER tai CIRCUIT #1 NO NC CIRCUIT #2 *—o /o PROVIDE TIMED OVERRIDE SWITCH PER NREC 1513.6.2 TORK SS20 OR EQUAL SET TO 2HR OVERRIDE MAX. LOCATE AT SWITCHBANK 20A1P A -13 0 0 20A1P A -17 0 0 20A1P A -19 0 20A1P 0 0 TORK ASTRONOMIC TIMESWITCH #EWZ201 OR EQUAL CIRCUIT #1 = INTERIOR LIGHTING CIRCUIT #2 = EXTERIOR LIGHTING 30A ELECTRICALLY HELD LIGHTING CONTACTOR (TYPICAL) CEILING FANS TRACK LIGHTING KITCHEN LIGHTING SPARE 20A1P A -25 0 0 20A1P. A -27 00 20A1P 0 0 20A1P /7■ 0 0 —0 120V REVIEWED' s+U►�t COMPLIANCE WITH NFPA 70 - NEC AUS 1 8 2011. City of Tukwila BUILDING DIVISION 30A ELECTRICALLY HELD LIGHTING CONTACTOR (TYPICAL) EXTERIOR SIGNAGE EXTERIOR SIGNAGE SPARE SPARE 1513.8 COMMISSIONING REQUIREMENTS: FOR UGHTING CONTROLS WHICH INCLUDE DAYLIGHT OR OCCUPANT SENSING AUTOMATIC CONTROLS, AUTOMATIC . SHUT —OFF CONTROLS, OCCUPANCY SENSORS, OR AUTOMATIC TIME SWITCHES, THE UGHTING CONTROLS SHALL BE TESTED TO ENSURE THAT CONTROL DEVICES, COMPONENTS, EQUIPMENT AND : SYSTEMS ARE CAUBRATED, ADJUSTED AND OPERATE . IN ACCORDANCE WITH APPROVED PLANS AND SPECIFICATIONS. SEQUENCES OF OPERATION SHALL BE FUNCTIONALLY TESTED TO ENSURE THEY OPERATE IN ACCORDANCE WITH APPROVED PLANS AND SPECIFICATIONS. SEE SECTION. 1416 FOR COMPLETE REQUIREMENTS. RECEIVED JUL 29 2011' PERMIT CENTER .k _ Abossein Engineering, L.L.C. MECHANICAL - ELECTRICAL CIVIL - LEED FIRE PROTECTION 2100 112TH AVE. NE BELLEVUE, WA 98004 PH: (425) 462.9441 FAX: (425) 462-9451 E-Mail: cselvice @abossein.com www.abossein.com 0 co I- D -J vJ�00 ZIW-co W 0 O U I- }-o� CO —ND �Nf-. 7• • Ci M W u a R .o O v C Qtr 0 a 44 %7 411.00• D -p N 0) O WE Pa M W :- 0 4— 0) w /4, `p CO W ii a�7o. u 2 t, So 0 j4 ,° 6' to : 4,1- Revisions ISSUE FOR JJ REVIEW L-7/18/2011 A REVISION PER JIMMY LLIJOHN'S 07/26/11 REVISION PER LL /ISSUE ©FOR PERMIT 07/27/11 (1) w cJ OOQ U w O 0 z 0. �<z w__Il=- z CL T w S 0 O —1 ARCHITECT U I IEREBY CERTIFY THAT TIESE PLANS HAVE BEEN RE- PARED MR SU'ERVISIai AND THAT TO TIE BEST IF NY KHCVLEDGE, THE SANE CORY PITH ALL RILES, REGULATIONS AND ORDINANCES OF TIEVILA. Vq RELATING TO STRUCTURES AND BUILDINGS, Drawn By Checked By Scale 1/4"=1'-;..0" Date 7/18/2011. Ibr 21 01 Sheet No. -2.1 (0F 4) ALL CABLING AND TERMINATION TO SUB — CONTRACTOR. COMM /DATA SUB — CONTRACTOR TO NECESSARY CONDUITS FOR CABLING BE COMPLETED BY COMM /DATA COORDINATE LOCATION AND SIZE OF WITH ELECTRICAL CONTRACTOR. DEDICATED DRIVERS DISPATCI EVERY COLD TA If PRINTER IS NOT NEXT TOA CASH REGISTER no All AODITIO,L&l PAINTER NUS). BC INSTAELEDAT IRE MAREUNE MANDATORY JACKS ;p;r����ar � .��.w� DRIVETHRU (ifapplicabI satti�;�ss.is�rlr�s;En� ABOVE :DRIVER'S BOXY Mack Jack =1,14 IMO Phone lack :. (for legacy credit card terminal dial-up backup) t iraNetwarklackTa future toeulderationor credit card terminal Orange lark =8145 Network lack EVERY WALLPLATE JACK IS A HOME RUN CATS TO RACKMOUNT PATCH PANEL s r� hus�czsy?x�X 4tP�� OFFICE f NEAR CEILIN„ LEGACY ((TERMINAL RAC KMOUNTPATCH PANEL ALL RACK EQUIPMENT INSIDE NETWORK CABINET Cer'L' Seta RACKMOUNT POWER DISTRIBUTION UNIT 3:ctr. RACKMOU NT 24 PORT SWITCH CABLE LEGEND CATS UTPCABLE HIDDEN IN WALL, CEILING OR FLOOR CATS CABLE PHONE LINE rna.ia•ir 6 -PORT SU RFACEMOUNT BOX FAX /DSL II NE ROUTER wI DIAL BACK -U P MI MODEM FAY IDSTII11 S SERVER OUTSIDE Abovedropteiltrg 812010 JIMMY JOHN'S FRANCHISE, LLC ALL RIGHTS RESERVED. DEMARCATION POINT — (DMARC) COMPONET BOX REQUIRED EQUIPMENT: COMPLETE COMPONENT BOX PROVIDED BY SIGNATURE SYSTEMS: NETWORK CABINET : MIDDLE ATLANTIC EWR817 OR EWR1017 REQUIRED EQUIPMENT VTHIN THE COMPONET CABINET: PATCH PANEL — PANDUIT CFAPPBL1 (QTY 1) POWER DISTRIBUTION UNIT — MIDDLE ATLANTIC PD- 915RV —R13 (QTY 1) 24 PORT NETWORK SWITCH — DELL POWER CONNECT 3524 (QTY 1) ROUTER WITH DIAL BACKUP — NETOPIA 4686XL WITH DIAL —UP (QTY 1) RACK SHELF — MIDDLE ATLANTIC U1R1 (QTY 2) CABLE STRAPS — MIDDLE ATLANTIC TW12 (QTY 1) PATCH CABLES —1' PATCH CABLES (QTY 10 * *) RACK SCREWS —10/32 RACK SCREWS (QTY 1 80X) VGA & USB WALL PLATE (QTY 2) VGA DUEL PANEL —MOUNT F/F CABLE QTY 1 USB 2.0 DUAL PANEL —MOUNT CABLE (QTY 1 CABLE ( 2.0 MINI COAX DH15MM (QTY 1) TY 1) * CALLER ID BOX IS ONLY REQUIRED FOR STORES THAT ARE INSTAWNG POS — PROVIDED BY SIGNATURE SYSTEMS. $* QTY IS NUMBER OF NETWORK RUNS PLUS 2 EXTRA VENDOR CONTACT: Signature, Systems, Inc 11 Penns Trail Newtown, PA 18940. Sales: (877) 968 -6430 or sales®pdgpos.com Fax: (215) 968 -6431 Dedicated JJ Tech Support: • (877) 844 -5313 DSL PHONE UNE MOUNTED WITHIN CABINET DUPLEX RECEPTACLE MOUNTED WITHIN CABINET DROP CEIUNG 10-6' A.F.F. NETWORK COMPONENT CABINET - EQUIP. WITHIN CABINET INCLUDE — 24 —PORT PATCH PANEL, ROUTER /SWITCH, DSL MODEM, CALLER ID RECESSED DATA UNE FROM ROUTER /SWITCH TO COMPUTER DATA FLUSH MOUNTED JUNCTION BOX FOR RECESSING SPEAKER WIRE KVM/VGA PORT PORT AND CABLE SUPPUED BY SIGNITURE SYSTEMS METRO DESK & SHELVES PROVIDED BY KEC AMOUNT OF HOMERUNS TO EQUAL THE AMOUNT OF DATA JACKS ON THE FLOOR PLANS. KVM/VGA PORT PORT AND CABLE SUPPUED BY SIGNITURE SYSTEMS AU. PHONE ONES ABOVE CEILING FROM PUNCHDOWN BLOCK TO 6 PORT SURFACE MOUNT BOX PANEL — ONE EA. FOR UNES A, B, C, & D AND TWO UNES FOR FAX/DSL UNE RECESSED 2' CONDUIT FOR VGA AND USB CABLES TO RUN BETWEEN VGA/USB PORTS — NO TURNS IN CONDUIT 3 DATA, 1 PHONE, & 2 QUAD RECEPTACLES SERIAL CABLE RECESSED 3 /4' CONDUIT STUBBED OUT ABOVE DROP CEILING FOR SPEAKER WIRE' RECESSED 2" CONDUIT FOR VGA AND USB CABLES TO RUN BETWEEN VGA/US8 PORTS — NO TURNS IN CONDUIT FOR THE DATASYM CASH REGISTER 0 iT) tp "to NETWORK CABINET DETAIL ELEVATION SCALE: NONE POWER DATA PHONES M 1' -6" 7 1/2" 6" 8 (0 CENTER UNE FRONT ELEVATION a CV in ELECTRICAL /DATA PHONE BANK DETAIL SCALE: NONE DINING A COOLER & FREEZER 1111.1111 FREEZER 6' x 6' REFRIG. 6' x 6' STORAGE 10' -6" CLNG. TILE C -1 D = VOICE D UNE 4 1- PHONE JACK `FROM FAX UN C = VOICE UNE 3 B = VOICE UNE 2 KITCHEN/PREP +X' -X "" B.O. ROOF DECK PAINT PT -5 DINING A 111111111 10' -6" CLNG. TILE C -1 7' -6" GYP. BD. SOFFIT PAINT PT-4 +12 "A.I•.1 -. al COMM /DATA PLAN DJSCALE: = 1'--0" 1 `i v k:•• Wli J 'r-L H b COMPLIANCE WITH NPPA70 -NEC N,,! ; 18 2011 City of Tukwila BUILDING DIVISION , RECEIVED JUL 29 2011 PERMIT CENTER Abossein Engineering, L.L.C. MECHANICAL - ELECTRICAL CIVIL - LEED FIRE PROTECTION 2100 112TH AVE. NE BELLEVUE, WA 98004 PH: (425) 462.9441 FAX: (425) 462.9451 E -Mail: cseivice @abossein.com wwvv.abossein.com 0 00 LLI ,D M co CO z CO = Ei O = �i co -D N c Du E U D Revisions A ISSUE FOR JJ REVIEW / \7/18/2011 A REVISION PER JIMMY JOHN'S 07/26/11 REVISION PER LL /ISSUE ©FOR PERMIT 07/27/11 ARCHITECT I t!REBY CERTIFY TWIT TIfSE PLANS HAVE BEEN PRE- PARED UNDER NT SUPERVISEN Attu THAT TO THE BEST ff NY IGUVLEDEE, THE SANE COFLY WITH ALL RULES, REGULATIONS AND ORDINANCES DF TLIKWILA. Va RELATING TO STRUCTURES AND BUILDINGS. Drawn By Checked By Scale 1/4"=1'-0" Date 7/18/2011 IT 21 01 Sheet No. C OV1 (OF 4) KEYED NOTES:' X 1. MOUNT THE NETWORK ELECTRONIC COMPONENT CABINET TIGHT TO CEIUNG ABOVE SHELVES IN THE BACK PREP AREA. SEE NETWORK CABINET DETAIL AND GENERAL NOTES ON THIS SHEET FOR INFORMATION ON CABUNG AND COMPONENTS WITHIN CABINET. SEE COMPONENT BOX EQUIPMENT UST ON COM -1 SHEET. 2. PROVIDE ONE (1) 3/4" CONDUITS STUBBED UP INTO ACCESSIBLE CEIUNG. VERIFY LOCATION IN FIELD FOR ALL VOICE AND DATA LOCATIONS.. SEE ELECTRICAL/DATA PHONE BANK DETAIL THIS SHEET. DATA LEGEND. . D DATA OUTLET (X) = AMT. OF DATA JACKS (JACK = ORANGE) 1 PHONE JACK (JACK = BLACK) O 2 DATA JACKS (JACK = ORANGE) & 1 PHONE JACK (JACK = BLACK) 3 DATA JACKS (JACK = ORANGE) & 1 PHONE JACK (JACK = BLACK) ® DATASYM POS — BELDEN STRANDED 4 —WIRE, UNTERMINATED VGA/USB PORT — 1 VGA JACK AND 1 USB JACK GENERAL NOTE: PHONE COMPANY TO PROVIDE 4 PHONE LINES ON ROLLOVER SERVICE & ONE (1) DSL/FAX LINE. GENERAL ELECTRICAL NOTES. . 1. RUN WIRING TO P.O.S. AND PREPARATION TABLES 1HRU WIRING CHASE PROVIDED IN THE CABINETS. CONCEAL CONDUIT RISER TO CEILING BEHIND WALL ARRANGE CONDUIT SO DATA WIRING CAN BE HOME RUNS TO THE PATCH PANEL WITHIN THE NETWORK CABINET ABOVE THE DESK. 2. SEE ELECTRICAL/DATA PHONE BANK DETAIL ON THIS SHEET FOR INSTALLATION OF PHONE/DATA EQUIPMENT 3. ALL PHONE CAT -5e HOME RUN TO PUNCHDOWN BLOCK. 4. ALL DATA CABLES TO TERMINATE ON RJ45 CATEGORY 5e JACKS AND WMRE TO EIA/11A 568 —B.1 STANDARDS. 5. ALL DATA CABLES TO HOMERUN AND TERMINATE ON 24 —PORT RACKMOUNT PATCH PANEL TO BE MOUNTED IN THE NETWORK CABINET. 6. ALL CABLES TO BE CONTINUITY TESTED FOR POLARITY AND CORRECT PIN CONFIGURATION AND MACHINE LABELED. 7. DAISY —CHAIN BELDEN STRANDED 4—WIRE (PROVIDED BY CASH REGISTER VENDOR) FROM EACH CASH REGISTER TO NEXT, THEN BACK TO MANAGER'S DESK. 8. AU. NETWORK CABUNG IN THE STORE MUST BE CATEGORY 5e CERTIFIED. YOU MUST OBTAIN A CERTIFICATION REPORT FROM YOUR COMMUNICATIONS /LOW VOLTAGE SUBCONTRACTOR. 9. STEREO SYTEM WIRING — SEE NETWORK CABINET DETAIL FOR JUNCTION BOX LOCATION AND RECESSED CONDUIT INSTRUCTIONS FOR STEREO SPEAKER IMRE. DINING A COOLER & FREEZER 1111.1111 FREEZER 6' x 6' REFRIG. 6' x 6' STORAGE 10' -6" CLNG. TILE C -1 D = VOICE D UNE 4 1- PHONE JACK `FROM FAX UN C = VOICE UNE 3 B = VOICE UNE 2 KITCHEN/PREP +X' -X "" B.O. ROOF DECK PAINT PT -5 DINING A 111111111 10' -6" CLNG. TILE C -1 7' -6" GYP. BD. SOFFIT PAINT PT-4 +12 "A.I•.1 -. al COMM /DATA PLAN DJSCALE: = 1'--0" 1 `i v k:•• Wli J 'r-L H b COMPLIANCE WITH NPPA70 -NEC N,,! ; 18 2011 City of Tukwila BUILDING DIVISION , RECEIVED JUL 29 2011 PERMIT CENTER Abossein Engineering, L.L.C. MECHANICAL - ELECTRICAL CIVIL - LEED FIRE PROTECTION 2100 112TH AVE. NE BELLEVUE, WA 98004 PH: (425) 462.9441 FAX: (425) 462.9451 E -Mail: cseivice @abossein.com wwvv.abossein.com 0 00 LLI ,D M co CO z CO = Ei O = �i co -D N c Du E U D Revisions A ISSUE FOR JJ REVIEW / \7/18/2011 A REVISION PER JIMMY JOHN'S 07/26/11 REVISION PER LL /ISSUE ©FOR PERMIT 07/27/11 ARCHITECT I t!REBY CERTIFY TWIT TIfSE PLANS HAVE BEEN PRE- PARED UNDER NT SUPERVISEN Attu THAT TO THE BEST ff NY IGUVLEDEE, THE SANE COFLY WITH ALL RULES, REGULATIONS AND ORDINANCES DF TLIKWILA. Va RELATING TO STRUCTURES AND BUILDINGS. Drawn By Checked By Scale 1/4"=1'-0" Date 7/18/2011 IT 21 01 Sheet No. C OV1 (OF 4)