Loading...
HomeMy WebLinkAboutPermit EL11-0763 - STARBUCKSSTARBUCKS COFFEE COMPANY 3301 S NORFOLK ST EL1 1 -0763 City oPfukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: htto: / /www.TukwilaWA.gov Parcel No.: 0323049024 Address: 3301 S NORFOLK ST TUKW Project Name: STARBUCKS COFFEE COMPANY ELECTRICAL PERMIT Permit Number: EL11 -0763 Issue Date: 10/21/2011 Permit Expires On: 04/18/2012 Owner: Name: ASSOCIATED GROCERS Address: P.O. BOX 3763 , SEATTLE, WA Contact Person: Name: ERIC HOPP Address: 2401 UTAH AV S, SUITE 800 , SEATTLE WA Contractor: Name: MASTERCRAFT ELECTRIC INC Address: 19717 62 AVE S D 10 , KENT WA Contractor License No: MASTEEI127B8 Phone: 206 - 318 -9309 Phone: 253 - 872 -2400 Expiration Date: 02/01/2012 DESCRIPTION OF WORK: ELECTRICAL FOR NEW RESTAURANT Value of Electrical: NRES: $25,000.00 RES: $0.00 Type of Fire Protection: UNKNOWN Electrical service provided by: Permit Center Authorized Signature: Fees Collected: $653.13 National Electrical Code Edition: 2008 � L4Lkk � Date: IO)1 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to • 've authority to violate or cancel the provisions of any other state or local laws regulating constructiapn or the performance of work. I - authorized to sign and obtain this electrical permit. Signature: Print Name: Date: 1 `c� 0-°4 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/10 EL11 -0763 Printed: 10 -21 -2011 1 PERMIT CONDITIONS Permit No. EL11 -0763 * *ELECTRICAL ** 1: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 2: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 3: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 4: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 5: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 6: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. doc: EL -4/10 EL11 -0763 Printed: 10 -21 -2011 CITY OF TUKWW Community Develop nt Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http: / /www.TukwilaWA.gov Electrical PertNo. 1 1' 0 -7 (p3 Project No. (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION King Co Assessor's Tax No.: / Site Address: 1 0 1 OU cal �u r 1 p cA 1 U y r Suite Number: /v Q Floor: Tenant Name: S %frt r-ia •� L h s Co ` l r C. G o.�^+ r.. s / New Tenant: V Yes ❑ .. No Property Owners Name: J l i ) Cb�t Mailing Address: ) Z L a( Ti..i k w, '1 1-1 /3) v d City State 9 rip/ Zip CONTACT PERSON — Who do we contact when your permit is ready to be issued Name: Pr` . ' L A 1 Day Telephone: Z O C Mailing Address: Z y b i Vl T a I+ A l/F -f Zoe. / q [/ D 4 E -Mail Address: G L /47/19 c9 L .c o ✓� City State Zip Fax Number: ELECTRICAL CONTRACTOR INFORMATION Company Name: Mailing Address: Contact Person: E -Mail Address: Contractor Registration Number: City Day Telephone: Fax Number: Expiration Date: State Zip Valuation of Project (contractor's bid price): $ 2 SP- /000 r Scope of Work (please provide detailed information): El, _ 1!� t c.-t / L v / AJCA-'4j , 4.c Will service be altered? ❑ Yes ❑ No Adding more than 50 amps? ❑ Yes ❑ No Type of Use: Type of work: ❑ New ❑ Addition ❑ Service Change ❑ Remodel ❑ Tenant Improvement ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service Property Served by: El Puget Sound Energy ❑ Seattle City Light H:\Applications\Porms- Applications On Line\2010 Applications \7 -2010 - Electrical Permit Application doc Revised: May 2011 bh Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $152.85 (including an attached garage) ❑ Garages, pools, spas and outbuildings $81.90 ea ❑ Low voltage systems (alarm, furnace thermostat) $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $81.90 (no added/altered circuits) ❑ Service change with added/altered circuits $81.90 number of added circuits $11.55 ea ❑ Circuits added/altered without service change $54.60 (up to 5 circuits) ❑ Circuits added/altered without service change $54.60 (6 or more circuits) $7.65 ea ❑ Meter /mast repair $68.25 ❑ Low voltage systems $59.85 (alarm, furnace thermostat) MULTI - FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $63.00 ❑ Temporary service (generator) $78.75 ❑ Manufactured/mobile home service $84.00 (excluding garage or outbuilding) ❑ Carnivals $78.75 Number of concessions $10.50 ea PERMIT APPLICATION NOTES - Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: Print Name: 4 -17e-N v -.t Mailing Address: /7 Z 4l / Date Application Accepted: JG �/ Date: ee r to k,,' Z,^1A) /lv4 Day Telephone: Z D ti Z P / F7 City State Zip Date Application Expires: Staff Initials: H:1ApplicationsTor s- Applications On Line12010 Applications17 -2010 - Electrical Permit Application.doc Revised: May 2011 bh Page 2 of 2 • • �J�` - - -- w City of Tukwila / \2 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov RECEIPT Parcel No.: 0323049024 Permit Number: EL11 -0763 Address: 3301 S NORFOLK ST TUKW Status: APPROVED Suite No: Applied Date: 08/16/2011 Applicant: STARBUCKS COFFEE COMPANY Issue Date: Receipt No.: R11 -02312 Initials: WER User ID: 1655 Payment Amount: $522.50 Payment Date: 10/21/2011 09:35 AM Balance: $0.00 Payee: MASTERCRAFT ELECTRIC INC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 27937 522.50 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.00 522.50 Total: $522.50 doc: Receipt -06 Printed: 10 -21 -2011 SET RECEIPT RECEIPT NO: R11 -01774 Initials: WER Payment Date: 08/16/2011 User ID: 1655 Total Payment: 958.23 Payee: DALE SPENCER SET ID: 08 -16 -11 SET NAME: STARBUCKS SET TRANSACTIONS: Set Member Amount D11 -282 655.79 EL11 -0763 130.63 M11 -116 85.71 PG11 -124 86.10 TOTAL: 655.79 TRANSACTION LIST: Type Method Description Amount Payment Credit C MC 958.23 TOTAL: 958.23 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES 000.345.832.00.0 PLAN CHECK - NONRES 000.345.830 130.63 827.60 TOTAL: 958.23 • INSPECTION RECORD ,Retain a copy with permit �a . INSPECPION NO: • PERMIT NO. -CITY OF TUKWILA BUILDING DIVISION • 6300 So"iithcenteY BI'vd.; #100, Tukwila. WA 98188 V-1 (206) 431 -36 t' • • Perth it. Inspectiori' Reis est Line (206) 431 -2451 rv. • • • • : • Project: (C `S Type of Inspection: 2400 Address:' 1 AQ'-ti Date Called: Special I nstructiont: . • Date Wanted:. 'Q a Requester: Phone No: Approved per applicable codes. a•Corrections required prior to approval. lz COMMENTS: • CoWIEu b,Js nvA+>6 Inspectbi:: Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Sbuthcenter Blvd.. Suite 100. Call to schedule reinspection. • • • • INSPECTION NO. INSPECTION.. RECORD Retain a copy with permit (tit 673 P MIT N0. . CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -36 Permit Inspection Request Line (206) 431 -2451 Project: t� Type of Inspection: 2/00 ' Address: Ag Date Called: T JI€.t Rif Afar kkviictilkl Special Instructions: . - Date Wanted:. / U a.m p.m. Requester: I L. "7.b e b {r1 ik 6 Amp Phone No: IJ.Approved per applicable codes. ® Corrections required prior to approval. COMMENTS: - Sot p 01JAI ri OA/ i -taAi roc a IA'C ( 0. 0 J ' SelIZAA a i fc,t -P Al rick ti . fie -rD fit 6tecA T JI€.t Rif Afar kkviictilkl ..., • t11. - arikers doKetrAiod5 scDpi6� L� ff ,, 45-rime It$na id i D►nt� �ISC�4 I L. "7.b e b {r1 ik 6 Amp a► P(ii > twil P Af i Inspector: N . REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be Date: paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 7 Project: ^., Type of Inspection: Z/0O Address: 330 t tCalled: Jb(d,Date . \ . . `" c1 dam' sr- 011/ Special Instructions: Date Wanted:. r 240‘ pm. Requester: Phone No: DApproved per applicable codes. Corrections required prior to approval. COMMENTS: ik- . . `" c1 dam' sr- 011/ t_vRk . — t.4 tL KTU u4 r ni ()Mr I R GIs) C,Rwir - tlissir41 Sf- ''s (4L i Si ) ript iwytilKik &E RRR°5 wkAiDtt aatif e, Opt NI. DJA0 try ( WI 6t.t- (S ,X NI. ICT�. ri REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspectiop. - a... - s.,,_. - ,44.41...41.. --- N INSPECTION NO. INSPECTION RECORD Retain a copy with permit RMIT NO CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -367 Permit Inspection Request Line (206) 431 -2451 Project: -C"",at)s Type of Inspection: . 70C$ 3 (0,6414 `'_ Address: 4)RJol..\Date Called: Special Instructions: ? Date Wanted:. f i /z._ a.m: Requester: Phone No: Approved per applicable codes. ElCorrections required prior to approval. COMMENTS: X' Co 6 cfc (tool. K61 (40 I a LOT Inspector: t (0,6414 `'_ \ Date: it REINSPECTION FEE REQUIRED. I?rior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 61 0. PERMIT N . • • • CITY OF TUKWILA BUILDING DIVISION .. 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: 1.1f f� Type of Inspection: 7 Address: 330 I Al Date Called: Special Instruction!: • . Date Wanted:. /I /2-2., a.m p.m. Requester: Phone No: id • INSPECTION RECORD Retain a copy with id ' . 'Inspector: �"''; Date: It 1124 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Approved per applicable codes. • • Corrections required prior to approval. COMMENTS: 1 . .., i id • • itt.lp / eifil 11M1 ©M5 • 6 6eaaV 41)I411 6134Di • • • 'Inspector: �"''; Date: It 1124 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. r. 4. INSPECTION NO. INSPECTION RECORD Retain a copy with permit FBI 0703 PERMIT NO. CITY OF' TUKWILA BUILDING DIVISION (� •63005outhcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: JlC.tC. 5 Type of Inspection: 700 3 Address: A • 1 • ._A) o .IVaR�g- Date Called: Special Instructions: .6-14... 1 IA . j )& t Date Wanted: . II Ka gi.. Requester: Phone No: Approved per applicable codes. •Corrections required prior to approval. COMMENTS: Te-K16 �lows min PIA-POLID5 Inspector: Critt&elisleik„ Date: 1 1 1 1 ( 9 1 1 1 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. - I INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT N CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -36 Permit Inspection Request Line (206) 431 -2451 Project: C S64c4( f� Type of Inspection: �/ 7 / Address: 3301 4ofLK. Date Called: Special Instructions: Date Wanted:. „ D ! a.m. Requester: Phone No: ElApproved per applicable codes. a Corrections required prior to approval. COMMENTS: dib St, %,11)hhTS 4i1T)PIIP( CW 4. co PR tie Inspector: i ,..1 . ! Date: lif r b T7 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. OP PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL11 -0763 DATE: 08 -16 -11 PROJECT NAME: STARBUCKS COFFEE COMPANY SITE ADDRESS: 3301 S NORFOLK ST X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: po__ Building Division !' Public Works Fire Prevention Structural Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 08-18-11 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Approved with Conditions Notation: REVIEWER'S INITIALS: DATE: DUE DATE: 09-15-11 Not Approved (attach comments) ri Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 Contractors or Tradespeople Peer Friendly Page • Electrical Contractor A business licensed by LEH to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company MASTERCRAFT ELECTRIC INC 2538722400 19717 62Nd Ave S D 110 Kent WA 98032 King Corporation UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 601059585 Active MASTEEI127B8 Electrical Contractor 1/28/1988 2/1/2012 General Unused Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status MASTEE'145BG MASTERCRAFT ELECTRIC Electrical Contractor General Unused 1/7/1986 1/31/1989 Archived ATOMEC'184KCATOM ELECTRIC CO Electrical Contractor General Unused 5/3/1982 12/31/1985 Archived Electrical Administrator INFORMATION License WALIOC'896JD Name WALIOR, CHAD Status Active Business Owner Information Name Role Effective Date Expiration Date WALIOR, CHAD P Agent 04/01/2007 Bond Amount WALIOR, CHAD P President 04/01/2007 SH4972 DARLING, GARY President 01/01/1980 04/01/2007 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 3 CBIC SH4972 08/29/2007 Until Cancelled $4,000.00 09/04/2007 2 AMERICAN STATES INS CO 6111711 05/03/2001 Until Cancelled 11/01/2007 $4,000.0003/28/2001 Assignment of Savings Information No records found for the previous 6 year period Insurance Information No records found for the previous 6 year period Summons /Complaint Information Summons and Complaints are not filed with the department for this contractor type Warrant Information Warrants are not filed with the department for this contractor type Infractions /Citations Information Infraction / Citation Date RCW Code Type Status Violation Amount EMABQ00232 8/6/2008 19.28.271 RCW ELECTRICAL CITATION Satisfied $250.00 https: / /fortress.wa. gov /lni/bbip /Print.aspx 10/21/2011 TELEPHONE SYSTEM NOTES: SECURITY SYSTEM NOTES ELECTRICAL ABBREVIATIONS ELECTRICAL LEGEND LEED SYSTEM COMMISSIONING ' co GENERAL CONTRACTOR SHALL CONTACT STARBUCKS GLOBAL NETWORK OPERATIONS CENTER (GNOC) PRIOR TO BEGINNING CONSTRUCTION TO ORDER TELEPHONE LINES. B REPORT ANY TELEPHONE INSTALLATION ISSUES IMMEDIATELY TO STARBUCKS GLOBAL NETWORK OPERATIONS CENTER (GNOC) VIA EMAIL: GNOGOSTARBUCKS.COM CONFIRM PRIOR TO BEGINNING CONSTRUCTION THAT LANDLORD HAS FURNISHED AND INSTALLED (1) 1h" CONDUIT INCLUDING PULL STRING FROM THE TELEPHONE POINT OF PRESENCE TO THE STARBUCKS WORKROOM. NOTIFY STARBUCKS CONSTRUCTION MANAGER (SEE SHEET G1.0) IMMEDIATELY IF CONDUIT AND PULL STRING ARE NOT INSTALLED. 0 ALL TELEPHONE /NETWORK CABLING IS THE SCOPE OF WORK OF THE TELEPHONE NETWORK CABLING VENDOR AND THE SECURITY SYSTEM VENDOR. TELEPHONE /NETWORK CABUNG VENDOR SHALL BE SCHEDULED SUCH THAT CABLING IS COMPLETE PRIOR TO ARRIVAL OF SECURITY SYSTEM VENDOR. GENERAL CONTRACTOR SHALL SCHEDULE ON -SITE WORK PERFORMED BY THE TELEPHONE EIYVORK CABLING VENDOR AND THE SECURITY SYSTEM /N VENDOR. THE TELEPHONE; //NETWORK CABLING VENDOR SHALL BE SCHEDULED SUCH THAT CABLING IS COMPLETE PRIOR TO ARRIVAL OF THE SECURITY SYSTEM VENDOR. 0 STARBUCKS SECURITY FOR TO FOR SCHEDULE CONTRACTS DIRECTLY WITH SECURITY VENDOR TO SUPPLY & INSTALL THE SYSTEM. CONTRACTOR TO SCHEDULE INSTALLATION OF SECURITY SYSTEM TWO TIMES, ROUGH -IN PRIOR TO DRYWALL INSTALLATION AND FINAL TRIM PRIOR STORE TURNOVER, SECURITY VENDOR REQUIRES A MINIMUM TWO WEEKS LEAD TIME EACH INSTALLATION. SECURITY VENDOR WILL COORDINATE REGIONAL INSTALLERS. ULE ACCORDINGLY WILL BE INCURRED TO THE RESPONSIBILITY OF THE CONTRACTOR. SECURITY VENDOR AFF AHJ APPROX 8L00 CLG CONST CW CM DL DEG DTI. DM DN DWG(S) EC ELEC EM (E) OR EXT EG F&I RR FT GC GFCI GND HR HVAC HW ABOVE FINISHED FLOOR LL LANDLORD AUTHORITIES HAVING JURISDICTION LV LOW VOLTAGE APPROXIMATE MAX MAXIMUM BUILDING CEILING MECH MECHANICAL MC MECHANICAL CONTRACTOR CONSTRUCTION MDP MAIN DISTRIBUTION PANEL COLD WATER MEP MECHANICAL, ELECTRICAL STARBUCKS CONST. MANAGER AND PLUMBING UGHTS W/IN DAYLIGHT ZONE MFG MANUFACTURER DEGREES MIN MINIMUM DETAIL NL NIGHTUGHT STARBUCKS DESIGN MANAGER NTS NOT TO SCALE DOWN OCP OVERCURRENT PROTECTION DRAWINGS) PM PROJECT MANAGER REF REFERENCE ELECTRICAL CONTRACTOR REQ('D) REQUIRE(D) ELECTRICAL REV REVISION/REVISION EMERGENCY SILT SHEET (EX) EXISTING SPECS SPECIFCAT1ON(S) EXTERIOR SF SQUARE FEET EXHAUST GRILLE SS STAINLESS STEEL FURNISH &INSTALL TEL TELEPHONE FLOOR TEMP TEMPORARY FOOT TYP TYPICAL /FEET GENERAL CONTRACTOR LINO UNLESS NOM OTHERWISE $ $ 3 M $ K $$$ SWITCH 0 JUNCTION BOX THREE WAY SWITCH 0 L.A.N. RECEPTACLE (OCCUPANCY) RECEPTACLE; SEE E -002 COMMISSIONING NOTES. �-+ /� ENERGY CODE CALCULATIONS SENSOR 0 UPL RECEPTACLE: KEYED SWITCH � 110 DEDICATED DUPLEX GFI SEE SEPARATE FORMS FOR ENERGY CODE COMPLIANCE. THE DIEBOLD COMPANY CONTACT: STARBUCKS PROJECT MANAGEMENT TEAM PHONE 206 318 6688 EMAIL: DOCC.STARBUCKSCDIEBOLD.COM SWITCHBANK L1 T ® {� 110 RECEPTACLE: RECEPTACLE TELEPHONE '• . 110 QUAD RECEPTACLE: /� POS i DATA LINE NOTES /� LANDLORD REC IREMENTS REQUIREMENTS 0 DATA TELEPHONE 0 STARBUCKS CATEGORY INSTALLATION A INSTALLERS, SCHEDULE REGISTER/MANAGER'S TECHNICIAN SCHEDULE DIRECTLY DELIVERY. � DATA ALL DATA DRAWERS F STARBUCKS DELIVERY CONTACTED CLUNG REFERENCED IN THIS SECTION IS SEPARATE FROM THE AND T -1 ORCUITS CONTRACTS DIRECTLY WITH THE DATA CABLING VENDOR TO SUPPLY AND INSTALL 5 LAN GABLE AND CONNECTORS F� THE POS SYSTEM. CONTRACTOR TO SCHEDULE OF DATA CABLING W/ DATA CABLING VENDOR. DATA CABLING VENDOR REQUIRES LEAD TIME FOR INSTALLATION, DATA CABLING VENDOR WILL COORDINATE REGIONAL ALL ADDITIONAL EXPENSES INCURRED DUE TO THE CONTRACTOR'S FAILURE TO ACCORDINGLY WILL BE THE RESPONSIBILITY OF THE CONTRACTOR. ANAGER'SNWORKSATION EQUIPMENT AND DEUVERY OF A DATA ACABLING FOR 'TWO DAYS PRIOR TO CONSTRUCTION END, CONTRACTOR TO VERIFY DELIVERY TWO WEEKS PRIOR TO DELIVERY AND INSTALLATION DATE. EQUIPMENT IS SHIPPED TO THE STORE, CONTRACTOR TO ACCEPT POS EQUIPMENT DEUVERY, DO NOT REFUSE CABLING TECHNICIAN TO PROVIDE ALL CATEGORY 5 LAN CABUNG AND CONNECTIONS TO DESIGNED AND FUTURE GASH REGISTER CATEGORY RY AND MANAGER'S WD CON ECTI CABLING TECHNIgAN TO REMOVE PACKAGING, INSTALL AND TEST CASH REGISTERS, CASH AND MANAGERS WORKSTATION. NEW STORE GROUP IS RESPONSIBLE FOR COORDINATING STARBUCKS POS SYSTEM AND INSTALLATION WITH THE DATA CABLING VENDOR. THIS GROUP MAY BE AT: NEWSTOREOSARBUCKS.COM ,� - . _ A SEDATE PERMIT REQUIRED FOR: e Mechanical THERMOSTAT 208V OR 220V THERMOSTAT SENSOR 2 GROUNDING ELECTRODE = CONNECTION DISCONNECT SWITCH DIMMER FUSED, IF NEEDED TIME CLOCK RACEWAY RACEWAY TO PANEL OR BETWEEN OUTLETS- CONCEALED UNO. WIRE QUANTITIES NOT SHOWN. SEE POWER AND LIGHTING SHEETS FOR WIRING REQUIREMENTS. Q PRIOR TO BID: THE CONTRACTOR SHALL COORDINATE WITH CONSTRUCTION f B UILDING OWNER SHALL BECOME /SPECIFICATIONS AND OWNER THAN SHOWN IN THESE LANDLORD /BUILDING SHALL COMPLETE WITH STARBUCKS IN K LANDLORD'S SCOPE OF PLANS, IT SHALL BE ANY BE BROUGHT TO 07(93 LANDLORD/BUILDING OWNER FOR ANY REQUIREMENTS /SPECIFICATIONS. IF LANDLORD DOES HAVE REQUIREMENTS, CONTRACTOR COMPLETELY FAMILIAR WITH REQUIREMENTS ADHERE TO THEM, WHERE LANDLORD /BUILDING REQUIREMENTS ARE MORE STRINGENT PLANS ON THE OWNER REQUIREMENTS OF THE GOVERN. ENGINEER), B LANDLORD'S SCOPE OF K: THE LANDLORD � TC T- MOBILE / T1 NOTES: GROUND FAULT CIRCUIT WP HEMET PROOF GROUND HOUR HEATING, VENTILATION, AIR CONDITIONING HOT WATER ric,�a PWAUIWas. 3301 S. Norfolk St. Tukwila, WA 98168 ALL CABLING AND INFRASTRUCTURE TO SUPPORT THE T- MOBILE T -1 HOTSPOT OR Wt -FI NETWORK SHALL BE FURNISHED AND INSTALLED BY T- MOBILE. THE T- MOBILE T -1 CIRCUIT WILL BE ORDERED BY T- MOBILE AND ALL STORES IDWILLRHAVE THIS RCtRCUITwNSTA�LEDA DEPLOYMENT NEW STORE NOT OPENING DATE, BUT A CABLE EXTENSION FOR THIS CIRCUIT WILL BE PROVIDED BY STARBUCKS TELEPHONE/NETWORK CABLING VENDOR AT THE SAME TIME AS THE TELEPHONE/NETWORK EXTENSIONS FOR FUTURE USE. OR THE SCOPE OF WORK AS UPON THE LANDLORD'S WORK LETTER. WHERE WORK IS INDICATED /CLARIFIED IN THESE FURNISHED AND INSTALLED AS SPECtFlED/INDICATED, QUESTIONS AND /OR DISCREPANCIES SHALL STARBUCKS ATTENTION FOR CLARIFICATION. FILE COPY mat No. EL 1 VI' GENERAL ELECTRICAL NOTES 1. EC SHALL VERIFY THE LOCATION OF ALL EXISTING UTILITIES PRIOR TO 5. DRAWINGS ARE DIAGRAMMATIC AND INDICATE GENERAL INTENT OR ARRANGEMENT OF CONSTRUCTION AND BE RESPONSIBLE FOR SITE INVESTIGATION PRIOR TO START OF SYSTEM(S). FOLLOW DRAWINGS IN LAYING OUT WORK AND COORD. WITH OTHER WORK TO REVEAL THE FULL SCOPE OF WORK. IN ADDITION, THE EC SHALL TRADES TO VERIFY SPACE CONDITIONS AND CLEARANCES, MAINTAIN HEADROOM AND THOROUGHLY EXAMINE ALL AREAS WHERE EQUIPMENT, CONDUIT, AND WIRING WILL SPACE CONDITION. -MAKE APPROPRIATE ADJUSTMENTS AT STARBUCKS DIRECTION, BE INSTALLED AND WILL REPORT ANY CONDITION THAT PREVENTS THE PROPER INSTALLATION OF THE ELECTRICAL WORK. 6, COORDINATE WITH OTHER TRADES FOR ANY NEEDED LOW VOLTAGE CONTROL WIRING AND DEVICES THAT IS NEEDED BUT MAY NOT BE SHOWN IN THESE DRAWINGS. 2 EC SHALL COORDINATE WITH THE GC TO PATCH AND REPAIR ALL EXISTING 7. UNLESS OTHERWISE NOTED SEE ARCH. SHEETS), THE CONTRACTOR SHALL REMOVE WALLS, FLOORS, CEILINGS OR OTHER SURFACES IDENTIFIED TO REMAIN THAT MAY ALL EXISTING ELECTRICAL EQUIPMENT INCLUDING INKING CONDUIT AND ALL OTHER BECOME DAMAGED LIKING THE COURSE OF WORK. MISC. DEVICES AS • DIRECTED BY THE GC THAT IS NOT BEING SALVAGED OR REUSED. 3. EXPOSED /SURFACE MOUNTED CONDUITS SHALL BE ROUTED IN A ORDERLY EQUIPMENT INDICATED ON DRAWINGS TO BE REUSED SHALL BE INSPECTED AND IF FASHION. SEE ADDITIONAL REQUIREMENTS ON E -111. DEFECTIVE, REPLACED. COORD. WITH GC AND STARBUCKS. 4. VERIFY LOCATION OF ALL OUTLETS AND SWITCHES WITH ARCHITECTURAL DRAWINGS, 8. THE EC SHALL BE RESPONSIBLE FOR DEENERGIZING CIRCUITS IN DEMOLITION AREAS INTERIOR DETAILS FINISH SCHEDULES, GENERAL CONTRACTOR, EQUIPMENT TO INSURE A SAFE CONDITION. ELECTRICAL DEVICES AND ASSOCIATED WIRING VENDORS, STARBUCKS AND EXISTING SITE CONDITIONS. VERIFY FINAL. DOOR HINGE LOCATED WITHIN THE DEMOLITION AREA 'NAT WILL NO LONGER BE USED LOCATION PRIOR TO SWITCH INSTALLATION AND ADJUST SWITCH LOCATION IF SHALL BE REMOVED AND PROPERLY DISPOSED OF AT CONTRACTORS EXPENSE NEEDED. DO NOT MOUNT RECEPTACLES /SWITCHES IN LOCATIONS THAT WOULD UNLESS OTHERWISE NOTED. CONFLICT WITH MIRRORS, SEAMS OF WALLS, WAINSCOTS, TILE TRANSITIONS, ETC. 9. THE EC SHALL SCHEDULE ALL ELECTRICAL SYSTEM(S) OUTAGES WITH THE GENERAL CONTRACTOR AND LANDLORD AT LEAST 24 HOURS IN ADVANCE. UNLESS APPROVED OTHERWISE ALL OUTAGES SHALL OCCUR BETWEEN 11:00PM AND 5 :00AM (AND DURING NON -STORE HOURS). MUSIC SYSTEM NOTES: C) PROVIDE AND INSTALL A COMPLETE WIRING SYSTEM FOR ALL SPEAKERS, _ ALL SPEAKERS TO THE OWNER PROMDED MUSIC SYSTEM. NOUN OWNER FURNISHED SPEAKERS WHERE SHOWN AND IN COORDINATION WITH ARCHITECTURAL PLANS AND DETAILS. FOLLOW MANUFACTURER'S INSTALLATION REQUIREMENTS. r is subject to errors and omissions. . construction documents does not authorize 1 of any adopted code or ordinance. Receipt .i Field Copy and conditions is a • 4 ,I Wedged: ■ Electrical &Plumbing Cirras Piping City of Tukwila BL IL DING DIVISION COMM U N I CAT ION SYSTEMS ,. ,., I l • lta-Yt at.Y Of Tukwila BUILDING DIVISION 0 STARBUCKS CONTRACTS DIRECTLY WITH THE LANDLORD TO PROVIDE FOUR (4) CAT5 (WHITE) COMMUNICATION CABLES TO THE SPACE. FOUR (4) CAT5 CABLES ARE MICAI D TO STORE OPERATIONS/COMMUNICATIONS. RACEWAYS CONDUCTORS AND TERMINATIONS NAMEPLATES GENERAL PANELBOARDS PROVIDE CODE APPROVED WIRING METHODS FOR BRANCH CIRCUITING INDOORS, SUCH AS EMT CONDUIT WITH COPPER CONDUCTORS OR MC CABLE(PROVIDED IT IS CONCEALED FROM VIEW AND NOT EXPOSED). ALL ABOVE GROUND CONDUITS SHALL BE EMT OR RIGID, MINIMUM 1/2" IN SIZE (LION). CONDUITS SHALL BE SIZED PER CODE AND AS NEEDED TO INSTALL CONDUCTORS. CONDUIT CONNECTORS SHALL BE DOUBLE LOCKNUT TYPE, UL LISTED AND LABELED, WITH COMPRESSION OR SET SCREW FITTINGS. PVC CONDUITS ARE NOT ALLOWED ABOVE SLAB UNLESS CODE AND AHJ APPROVED/LISTED FOR THAT USE CONDUIT RUNS ON EXTERIOR OF BUILDING SHALL BE CONCEALED AND BE RIGID STEEL CONDUIT WITH WEATHER TIGHT, CORROSION- RESISTANT FITTINGS (OR PVC WHERE LISTED FOR EXTERIOR- DIRECT SUNLIGHT USE). CONDUIT SHALL NOT BE RUN EXPOSED WITHOUT SPECIFIC PERMISSION FROM THE CONSTRUCTION MANAGER, WHERE RACEWAYS ARE INSTALLED FOR OTHERS TO USE, OR FOR FUTURE USE, PROVIDE NYLON PULL STRINGS END TO END WITH A LABEL ON BOTH ENDS STATING USE AND LOCATION OF OTHER STUB (E.G. DATA -FRONT POS). PENETRATIONS THROUGH FIRE RATED CONSTRUCTION SHALL BE SEALED USING 3M FIRE BARRIER CAULK, NELSON ELECTRIC FLAMESEAL OR T &B FLAMESAFE OR OTHER METHOD APPROVED BY THE ARCHITECT AND AHJ. RUNS CONCEALED IN CONCRETE OR UNDERGROUND SHALL BE 3/4" MINIMUM, UNLESS OTHERWISE NOTED W/RIGID STEEL ELBOWS, CONDUIT CONNECTORS SHALL BE DOUBLE LOCKNUT TYPE, UL LISTED AND LABELED, WITH COMPRESSION OR SET SCREW FITTINGS, IF CONDUIT RACEWAYS CANNOT BE RECESSED IN WALLS DUE TO CONSTRUCTION OR EXISTING CONDITIONS, PROVIDE A STEEL SURFACE MOUNTED RACEWAY SYSTEM (WIREMOLD, HUBBEL OR APPROVED EQUAL) WITH ALL COMPATIBLE DEVICES. THIS TYPE OF SYSTEM IS ONLY ALLOWED WHERE APPROVED BY STARBUCKS INCLUDING LAYOUT, CONFIRM COLOR AND ANY CUSTOM FINISHES WITH STARBUCKS. CONDUCTORS; SHALL BE COPPER, INSULATED FOR 600V, TYPE THWN /114HN, NUMBER 12 AWG MINIMUM UNO. MOTORS AND OTHER WIRING: THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL NEEDED CONDUIT, WIRING, CONNECTIONS, AND SAFETY SWITCHES FOR ALL MOTORS, AND EQUIPMENT, EVEN IF THE MOTORS AND EQUIPMENT ARE SUPPLIED BY OTHERS. MOTORS, CONTROLS, ETC. MAY BE FURNISHED BY THE SUPPLIER OF THE DRIVEN EQUIPMENT. THE ELECTRICAL CONTRACTOR SHALL INCLUDE ALL WORK AND CONNECTIONS NEEDED TO MAKE THE SYSTEM COMPLETE AND OPERATIONAL. ALL CONNECTIONS TO MECHANICAL EQUIPMENT SHALL BE DONE BY THE ELECTRICAL CONTRACTOR, THE ELECTRICAL CONTRACTOR SHALL VERIFY EQUIPMENT LOCATION AND SIZES WITH THE TRADE AND VENDOR SUPPLYING THE EQUIPMENT PRIOR TO ROUGH --IN. PROVIDE PHENOLIC NAMEPLATES ON ELECTRICAL DEVICES SUCH AS DISCONNECTS AND PANELS WITH THEIR DESIGNATION (E,G, "PANEL A "). PROVIDE DIRECTORY FOR PANELS AND LABEL ALL BREAKERS. 1F A TRANSFORMER IS INSTALLED, PROVIDE NAMEPLATE ON TRANSFORMER AS FOLLOWS: "HOT SURFACE, DO NOT PLACE ANY " ITEMS ON TOP OR ON SIDES OF TRANSFORMER". NOTE: "CONTRACTOR" MEANS "ELECTRICAL CONTRACTOR" WHEN REFERENCED ANYWHERE IN THE ELECTRICAL CONSTRUCTION DOCUMENTS UNLESS WORK AND EQUIPMENT HAS BEEN COORDINATED BETWEEN THE ELECTRICAL AND GENERAL CONTRACTORS TO BE PROVIDED BY THE GENERAL CONTRACTOR, "NEEDED", PROVIDE ", AND INSTALL MEANS ALL ITEMS CALLED OUT IN THE CONTRACT DOCUMENTS AND ANY ADDITIONAL ITEMS NOT CALLED OUT BUT REQUIRED TO MAKE A COMPLETE AND OPERATIONAL SYSTEM. THE INTENT OF THE SPECIFICATIONS AND THE DRAWINGS IS TO PROVIDE A COMPLETE AND FULLY OPERATIONAL ELECTRICAL SYSTEM. THE ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL LABOR, MATERIAL AND EQUIPMENT NECESSARY TO COMPLETE THE ELECTRICAL WORK. PERMITS AND FEES: THE ELECTRICAL CONTRACTOR SHALL PROCURE AND PAY FOR ALL PERMITS, FEES AND INSPECTIONS NECESSARY TO COMPLETE THE ELECTRICAL SCOPE OF WORK PRIOR TO STARTING THE WORK. WARRANTY: THE ELECTRICAL CONTRACTOR SHALL UNCONDITIONALLY WARRANT ALL WORK TO BE FREE OF DEFECTS IN MATERIAL AND WORKMANSHIP FOR A PERIOD OF ONE (1) YEAR FROM THE DATE OF FINAL ACCEPTANCE BY STARBUCKS AND WILL REPAIR OR REPLACE ANY OTHER EX WORK WORK PROMPTLY M AND WITHOUT CHARGE AND RESTORE ANY OTHER EXISTING WORK DAMAGED IN THE COURSE OF REPAIRING DEFECTIVE MATERIALS AND WORKMANSHIP. TEMPORARY POWER: REUSE EXISTING PANEL (IF IN GOOD CONDITION) AND SERVICE FOR TEMPORARY CONSTRUCTION PO R. ALL RECEPTACLES TO BE USED DURING CONSTRUCTION SHALL BE GFI PROTECTED. PERFORM ALL WORK IN ACCORDANCE WITH THE CURRENT NATIONAL ELECTRICAL CODE, STATE CODES, CITY ELECTRICAL, CODES, AND ALL OTHER APPLICABLE CODES INCLUDING ANY STATE OR LOCAL ENERGY CODES. ALL WORK SHALL ALSO BE IN COMPLIANCE WITH BUILDING OWNER'S CRITERIA. IN CASE OF CONFLICT BETWEEN THE DRAWINGS, SPECIFICATIONS, CODES, ORDINANCES, AND AUTHORITIES HAVING JURISDICTION, THE MOST STRINGENT STANDARD (IN THE OPINION OF THE ENGINEER) SHALL APPLY. THE EC SHALL SATISFY CODE, AHJ, DRAWINGS, AND SPECIFICATIONS AS A MINIMUM STANDARD WITHOUT ANY EXTRA COST. EQUIPMENT AND MATERIALS SHALL CONFORM WITH APPROPRIATE PROVISIONS OF NEC, WAC, AST I, UL, ETL, NEMA, ANSI, AND OTHER APPLICABLE AGENCY AS THEY APPLY TO EACH INDIVIDUAL UNIT OR ASSEMBLY. ALL ELECTRICAL :YcSiltromfMau,S73gSHriecsAtivLsiLthhaBoiE TESTED FOR PROPER OPERATION, BALANCE ALL BRNCH CIRCUIT LOADS BETWEEN THE PHASES OF THE SYSTEM TO WITHI 1O OF TH£ HIGHEST PHASE LOAD IN EACH PANELBOARD, REVISIONS l be made to the sco pQ ut pnor approval of f Tuk�r,ta Building Division. I t!T : s�is €Qn ,,j[viii,Jr�e1 ♦wire a new plan submittal La , may in:lude additional n6an rn. • . t_ PANELBOARDS SHALL HAVE PLUG -IN OR BOLT LUGS ONLY OR MAIN BREAKERS AS NEEDED PANELBOARDS SHALL BE CONSTRUCTED WITH ENCLOSED IN NEMA 1 HOUSING (OR AS REVD MANUFACTURED BY SQUARED , CUTLER HAMMER CAPABLE OF ACCEPTING GFI BREAKERS. ENCLOSURE(S) COMPLETE WITH A HINGED DOOR, CYLINDER LOCK, CIRCUIT BREAKER DIRECTORY UNDER PLASTIC DOOR, ALL MULTIPLE POLE BREAKERS (AND CODE) SHALL HAVE A COMMON TRIP HANDLE. 111%- ON BREAKERS AND MAIN OR REQUIRED. ALUMINUM BUS AND BE BY CODE) AS ", OR EQUAL AND SHALL BE AND A NEATLY TYPED COVER IN EACH PANEL OTHER BREAKERS REQ'D BY ' t MOUNT 1 N G G MOUNT DISCONNECTS TO STRUCTURE, INDEPENDENT OF THE MECHANICAL UNIT HOUSING OR WITH INDEPENDENT UNISTRUT SUPPORT. DISCONNECTS MOUNTED TO UNITS ARE ONLY ALLOWED WHERE ACCEPTED BY THE LOCAL CODE AUTHORITY AND LOCATED SO AS TO NOT BLOCK ACCESS OR LABELS OF UNIT, REVIEWED FOR CODE COMPLi NCE APPROVED AUG 1 q 2011 City of Mita& BUILDING DIVISION LOW V0LTAG E GROUNDING ALL LOW VOLTAGE WORK SHALL COMPLY, BE PERMITTED AND INSPECTED PER STATE (AND AHJ) REQUIREMENTS. ALL LOW VOLTAGE WORK SHALL BE INSTALLED BY A LICENSED CONTRACTOR IN ACCORDANCE WITH THE STATE AND AHJ REQUIREMENTS. ALL LOW VOLTAGE CABLING INSTALLED UNDERGROUND SHALL BE ROUTED IN A CONDUIT RACEWAY AND - CABLING /CONDUCTORS SHALL BE LISTED F O R USE IN WET LOCATIONS, FOR LOW VOLTAGE APPLICATION AND PER AHJ, ALL LOW VOLTAGE CABUNG ROUTED INDOORS SHALL BE ROUTED CONCEALED IN WALLS /CEILINGS IN A CONDUIT RACEWAY (UNLESS OWNER AND AHJ AUTHORIZE IT TO BE ROUTED EXPOSED THROUGH WALL /CEILING). IF APPROVED BY OWNER & AHJ TO BE ROUTED EXPOSED, CABUNG SHALL BE PROPERLY FASTENED /SUPPORTED PER CODE, AHJ, AND INDUSTRY STANDARDS, CABLING NOT ROUTED IN CONDUIT SHALL BE PLENUM RATED WHERE REQUIRED BY CODE OR AHJ (CONFIRM WHETHER CEILING SPACE IS BEING USED AS AN AIR PLENUM.) ALL LOW VOLTAGE CABLING OUTDOORS (E.G. ON ROOF) SHALL BE ROUTED IN CONDUIT PER CODE AND AHJ REQUIREMENTS UNLESS SPECIFICALLY USTED AND LABELED FOR EXTERIOR USE ALL MAJOR PARTS NOT CARRYING CURRENT, INCLUDING BUT NOT UNITED TO, SECONDARY FEEDER CIRCUIT, EQUIPMENT AND PANELBOARD ENCLOSURES, PULL AND JUNCTION BOXES AND OTHERS DEFINED BY CODE, SHALL BE PROPERLY GROUNDED. METALLIC RACEWAYS SHALL UTILIZE DOUBLE LOCKNUTS AND OTHER FITTINGS TO PROVIDE GROUND CONTINUITY, 0 7 ‘t3 UGH-TING 1 �•�► SHEET L E' rTR I CAL �.7 E ET INDEX V V E INSTALL LIGHTING SYSTEMS) COMPLETE AND FULLY OPERATIONAL AND IN CONFORMANCE WITH CODE, AHJ AND FIXTURE LISTING AGENCY REQUIREMENTS. CLEAN ALL FIXTURES AT TIME OF JOB COMPLETION UTILIZING MANUFACTURERS APPROVED OR RECOMMENDED CLEANING SOLUTIONS. ALL FIXTURES AND LAMPS SHALL BE AS SCHEDULED AND APPROVED BY STARBUCKS, E -041 ELECTRICAL SPECIFICATIONS E -002 ELECTRICAL PANEL. SCHEDULES & ONE -LINE DIAGRAM E -111 POWER PLAN E -112 LIGHTING PLAN & SCHEDULE E -113 UPPER LEVEL POWER & LIGHTING PLAN E -501 ELECTRICAL DETAILS -�* AND u ��++ C MATERIALS 1 ERIAL AND METHODS BASIC M �1�t BA MATERIALS: PROVIDE ALL NEW MATERIAL AND EQUIPMENT UNLESS NOTED OTHERWISE. ALL EQUIPMENT SHALL BE UL APPROVED, LABELED, AND LISTED OR OTHER APPROVED TESTING ORGANIZATION WHICH HAS ACCEPTANCE BY THE AUTHORITIES HAVING JURISDICTION FOR THE PURPOSE FOR WHICH THEY ARE USED IN ADDITION, MEETING ALL REQUIREMENTS OF THE CURRENT APPLICABLE CODES AND REGULATIONS, NO SUBSTITUTION OF MATERIALS SPECIFIED WILL BE ALLOWED UNLESS NOTED OTHERWISE, ALL ITEMS ARE NEW UNLESS OTHERWISE NOTED, CUTTING AND FITTING; PERFORM CUTTING, CORING, FITTING, REPAIRING AND FINISHING OF THE WORK NECESSARY FOR THE INSTALLATION OF THE EQUIPMENT. HOWEVER, NO CUTTING OF THE WrORK OF OTHER TRADES OR OF ANY STRUCTURAL MEMBER SHALL BE DONE WITHOUT THE CONSENT OF THE ARCHITECT, CONSTRUCTION MANAGER, GC, AND /OR OWNER. PROPERLY FILL, SEAL, FIREPROOF, AND WATERPROOF ALL OPENINGS, SLEEVES AND HOLES IN SLABS, WALLS, AND CASEWORK. SWITCHES AND RECEPTACLES SWITCHES: LUTON COMMERCIAL GRADE OR APPROVED EQUAL WITH DURABLE COVERPLATES. COORDINATE WITH STARBUCKS DM FOR COVERPLATE TYPE ( E.G. STAINLESS STEEL) AND FOR COLOR OF SWITCH AND PLATE. RECEPTACLES: LE1ITON COMMERCIAL GRADE' OR APPROVED EQUAL WITH DURABLE COVERPLATES, COORDINATE i1H STARBUCKS DM FOR COVERPUATE TYPE (E.G. STAINLESS STEEL) AND FOR COLOR OF RECEPACLE AND PLATE. INSTALL RECEPACLES PLUMB, LEVEL, AND SECURE TO J -BOX. PROVIDE GFCI TYPE WHERE INDICATED AND WHERE REQUIRED BY CODE AND AHJ. GFCI RECEPTACLES SHALL BE CLASS A RATED FOR PERSONNEL PROTECTION. OCCUPANCY SENSORS• SENSORSWITCH WSD SERIES FOR SINGLE OCCUPANT RESIROOMS AND CLOSETS AND FOR P SWITCH WSD -1'DT SERIES (PER AND ULTRASONIC SOUND ACTIVATED) FOR PARTITIONED RESTROOMS. ECEIVED AUG 1 6 2011 PRMITCENTER , ��T�T =R 4�? vi' ` M t �a I l'' s;ia �' s OIST%- '5!on' �+ �+ u I U S E D SWITCHES FUSED SWITCHES: HEAVY DUTY TYPE, HORSEPOWER RATED WITH INTERLOCKING COVER. NEMA 1 TYPICAL OUTDOOR AND WET LOCATION SWITCHES SHALL BE RAINTIGHT TYPE NEMA 3R. ALL SWITCHES SHALL BE LOCKABLE. FUSES IN CIRCUITS RATED AT 600 TIME DELAY CURRENT AMPERE =S OR LESS SHALL BE UL CLASS RK1 DUAL- �EL£MENT, , LIMITING FUSEES. FUSES IN CIRCUITS RATED AT 601 AMPERES OR LARGER SHALL BE UL CLASS L TIME - DELAY, CURRENT LIMITING SWITCHES. I EXPIRES A> z e/ J Starbucks Coffee Company 2401 Utah Avenue South Seattle, Washington 98134 (206) 318 -1575 These Drawings and Specifications are confidential and shall remain the sole property of Starbucks Corporation. They shall not be reproduced (in whole or in part), shared with third parties or used In any manner on other projects or extensions to this project without the prior written consent of Starbucks Corporation. These drawings and specifications are intended to express Design intent for a prototypical Starbucks store (which is subject to change at anytime) and do not reflect actual site conditions. Neither party shall have any obligation nor liability to the other (except as stated above) until a written agreement is fully executed by both parties. RENBCH ENQINIB�RINQ 4►C 111 AVL C SUM 104, SNOHOMISH, 98290 PIO 3604165.6877 Ma 4254494099 ronsch.englneeringQcomcast.net Revision Schedule Rev Date By Description ric,�a PWAUIWas. 3301 S. Norfolk St. Tukwila, WA 98168 Store #: Project #: Issue Date: Sbux Design Manager: Designed by: Drawn by: Checked by: TBD 5/2/11 Anthony Perez Chris Rensch Yumi Roth Chris Rensch Sheet Title: Scale: Electrical Specifications Sheet Number: E -QO1 ALL IS NEW UNLESS OTHERWISE NOTED. OUTSIDE OF STARUCKS SPACE IN STARBUCKS SPACE TO UTILITY TRANSFORMER 400 AMP CT COMPARTMENT, NEMA 3R, "CIRCLE AWW" ENCLOSURE WITH CT MOUNTING BASE. CONFIRM REQUIRED BOX SIZE AND REQUIREMENTS WITH POWER COMPANY. POWER METER AND SOCKET PER LOCAL POWER COMPANY'S REQUIREMENTS. 2 EACH - 2 -1/2 "C EACH WITH 4 #250KCM AL., THWN & GND 100A /3P�� ., PANE A" PANELL "B" 42 SPACE 42 SPACE 400A /3P MAIN 4 #3 CU. & GND, 1 -1/4 "C NOTE: EQUIPMENT AIC RATINGS SHALL EXCEED THE AVAILABLE FAULT CURRENT. CONTRACTOR SHALL VERIFY AVAILABLE FAULT CURRENT WITH UTILITY PRIOR TO CONSTRUCTION. SYSTEM SHALL BE SERIES RATED IF NECESSARY TO LIMIT SHORT CIRCUIT CURRENT TO BELOW 22,000 AIC (FOR GFI BREAKERS). COORDINATE WITH LANDLORD. SERVICE ONE LINE DIAGRAM NTS NOTES GA GR GFI GFI GFI PANEL A VOLTAGE: 208 V/120V 3PH, 4W MAIN BREAKER: 400 AMP FED FROM: MDP AIC RATING: EXCEED AVAILABLE (SEE RISER) BUS: 400 AMP LOCATION: WORKROOM SERVES TYPE LOAD CKT BRKR CKT NO. . CKT LOAD PHASE LOADS CKT LOAD CKT N0. CKT BRKR TYPE LOAD SERVES AMP 1 PULE A B C AMP POLE RTU -1 H 40 /3 1 4,378 4,578 600 200 2 20 /1 CL TRASH EXHAUST FAN HOT BOX H 3 - 4,378 4,778 0 400 4 20 /1 L TRASH LIGHTING SPARE H 5 4,378 4,738 360 6 20 /1 R HVAC REC ESPRESSO MACHINE K 40 /2 7 3,300 3,660 700 360 8 20 /1 NC - HVAC SMOKE DETECTOR SPARE K 9 3,300 7,800 - 1,500 4,500 10 60 /2 K HOT WATER TANK ESPRESSO MACHINE K 40 /2 11 3,300 7,800 4,500 12 12 K NC PHONEBOARD K 13 3,300 4,860 0 1,560 14 20 /1 K BLENDER TWIN BREWER K 50 /2 15 4,100 4,460 1,200 360 16 20 /1 R HVAC REC / LIGHT MANAGERS DESK K 17 4,100 4,460 360 18 20 /1 R HVAC REC / LIGHT DISHWASHER K 50 /2 19 3,952 6,770 1,700 Z818 20 30 /3 H RTU -2 M_ A RS !.t;,_ _. _ K K 21 3,952 1,900 6,770 Z200 2,818 22 22 H L WARMER K 20 /1 23 660 3,478 2,818 24 24 H L WARMING U/C REFRIG K 15 /1 25 840 1,040 1,080 200 26 20 /1 NC DT WINDOW GRINDER/SCALE K 20 /1 27 1,400 2,240 1,000 840 28 20 /1 NC DT POS CUP LABELER K 20 /1 , 29 360 1,260 900 30 20 /1 NC DT POS EQUIPMENT RESTROOM HEATER H 20 /1 31 1,000 1,200 1,040 200 32 . 20 /1 NC SAFE SPARE HOT TAP 20 /1 33 33 1,356 0 1,356 34 20 /1 20 /1 SPARE SPARE WARMING OVEN 20 /1 35 35 2,950 1,560 1,560 36 20 /1 K BLENDER SUBFEED TO PANEL B 100 /3 37 8,870 9,710 3,750 840 38 15 /1 K U/C REFRIG SPEAKER POST SPARE 39 6,956 6,956 0 40 20 /1 20 /1 SPARE SPARE SPARE 41 7,610 7,610 0 42 20 /1 20 /1 SPARE PANEL TOTAL KITCHEN LOAD = TOTAL LIGHTING LOAD = TOTAL NON -CONL LOAD = TOTAL RECEPTACLE LOAD = TOTAL CONTINUOUS. LOAD = TOTAL HVAC LOAD = LARGEST MOTOR LOAD = TOTAL KVA = TOTAL AMPS = PHASE A PHASE CONN. KVA CONNECTED CONNECTED AMPS WATTS = AMPS = DEMAND FACTOR 31,818 33,004 ' 30,906 LOAD TYPE KEY: K = KITCHEN LOAD L = LIGHTING LOAD NC = NON - CONTINUOUS LOAD R = RECEPTACLE LOAD CL = CONTINUOUS LOAD H = HVAC LOAD I-N = LARGEST MOTOR LOAD /120V 3PH, 4W 265 275 258 = = = = = = = = DEMAND = DEMAND KVA UNDER 1OKW AMPS0208V 56.72 3.30 9.74 2.58 0.80 22.59 0.00 X 0.65 X 1.25 X 1.0 X 1.0 X 1.25 X 1.0 X 1.25 36.87 4.13 9.74 2.58 1.00 22.59 0.00 95.7 76.9 CONN. AMPS 266 1 214 NOTES GFI GF1 NOTES: GFI - F&I NEW GFI BREAKERS (RATED FOR PERSONNEL PROTECTION PER CODE) AND DEDICATED NEUTRALS FOR THESE CIRCUITS TO PREVENT FALSE TRIPPING. EQUIPMENT AIC RATINGS SHAM EXCEED THE AVAILABLE FAULT CURRENT. CONTRACTOR SHALL VERIFY AVAILABLE FAULT CURRENT WITH UTILITY PRIOR TO CONSTRUCTION. SYSTEM SHALL BE SERIES RATED IF NECESSARY TO LIMIT SHORT CIRCUIT CURRENT TO BELOW 22,000 AIC (FOR GFI BREAKERS). NOTES GR GFI GR GA GFI GR OR GFI GFI PANEL B VOLTAGE: 208 V /120V 3PH, 4W MAIN BREAKER: MLO FED FROM: PANEL. A AIC RATING: EXCEED AVAILABLE BUS: 200 AMP LOCATION: WORKROOM SERVES TYPE LOAD CKT BRKR CKT NO. CKT LOAD PHASE LOADS CKT LOAD CKT N0. CKT BRKR TYPE LOAD SERVES AMP I KM A 8 C AMP POLE RESTROOM EXHAUST FAN CL 20 /1 1 200 600 400 2 20 /1 CL HOT BOX SPARE 20 /1 3 0 4 20 /1 SPARE SPARE 20 /1 5 0 6 20 /1 SPARE BAR /WORKROOM LIGHTING L 20 /1 7 700 , 700 -8 20 /1 SPARE SPARE 20 /1 9 - 1,500 1,500 10 20 /1 R WORKROOM OUTLET SPARE 20 /1 11 360 360 12 20 /1 NC PHONEBOARD SPARE 20 /1 13 0 14 20 /1 SPARE SPARE 20 /1 15 1,200 1,200 16 20 /1 NC MANAGERS DESK SPARE 20 /1 17 1,200 1,200 18 20 /1 NC MANAGERS DESK REACH --IN REFER K 15 /1 19 1,200 1,700 �.. _. • _ 0 1 _ N M_ A RS !.t;,_ _. _ ICE MACHINE K 20 /1 ' 21 1,900 Z200 300 22 20 /1 L EXTERIOR LIGHTS SPARE 20 /1 23 1,500 1,500 24 20 /1 L EXTERIOR LGHTS SPARE 20 /1 25 1,080 ,r :i 26 20 NC D •'-i'3. 'ON • - YISC.M-S SPARE 20 /1 27 1,000 1,000 28 20 /1 NC DT COMM BASE /CCTV SPARE 20 /1 29 900 900 30 20 /1 NC DT POS & EXPEDITOR U/C REFRIG K 15 /1 31 840 1,040 200 32 20 /1 NC DT WINDOW HOT TAP K 20 /1 33 1,356 1,356 34 20 /1 SPARE WARMING OVEN K 30 /2 35 2,950 4,150 1,200 36 20 /1 L DT MENU BOARD/ IGNAGE/UGHTS K 37 2450 3,750 800 38 20 /1 NC SPEAKER POST SPARE 20 /1 39 0 40 20 /1 SPARE SPARE 20 /1 41 0 42 20 /1 SPARE TOTAL KITCHEN LOAD = TOTAL LIGHTING LOAD = TOTAL NON -CONT. LOAD = TOTAL RECEPTACLE LOAD = TOTAL CONTINUOUS LOAD = TOTAL HVAC LOAD = LARGEST MOTOR LOAD = TOTAL KVA = 1 TOTAL AMPS - PHASE PHASE CONN. KVA CONNECTED CONNECTED AMPS WATTS = AMPS = DEMAND FACTOR 8,870 7,256 8,110 LOAD TYPE KEY: K = KITCHEN LOAD L = LIGHTING LOAD NC = NON - CONTINUOUS LOAD R = RECEPTACLE LOAD CL = CONTINUOUS LOAD H = HVAC LOAD LM = LARGEST MOTOR LOAD /120V 3PH, 4W 74 60 68 = = = = = = = = DEMAND = DEMAND KVA UNDER 10KW 1AMPSS208V 11.20 3.70 7.24 1.50 0.60 0.00 0.00 X 0.65 X 1.25 X 1.0 X 1.0 X 1.25 X 1.0 X 1.25 7.28 4.63 7.24 1.50 0.75 0.00 0.00 24.2. CONN. AMPS -67 1 1 59 NOTES: GFI - F&I NEW GFI BREAKERS (RATED FOR PERSONNEL PROTECTION PER CODE) AND DEDICATED NEUTRALS FOR THESE CIRCUITS TO PREVENT FALSE TRIPPING. EQUIPMENT AIC RATINGS SHALL EXCEED THE AVAILABLE FAULT CURRENT. CONTRACTOR SHALL VERIFY AVAILABLE FAULT CURRENT WITH UTILITY PRIOR TO CONSTRUCTION. SYSTEM SHALL BE SERIES RATED IF NECESSARY TO UMIT SHORT CIRCUIT CURRENT TO BELOW 22,000 AIC (FOR GFI BREAKERS). NOTES GFI GFI GFI LEED SYSTEM COMMISSIONING CONTRACTOR RESPONSIBILITIES FOR BUILDING COMMISSIONING CONTRACTOR SHALL PROVIDE SUPPORT AND WORK AS SPECIFIED, NEEDED AND REQUIRED TO CONDUCT AND FACILITATE STARBUCKS STAFF BUILDING COMMISSIONING EFFORTS. THIS WORK WILL BE COMPRISED OF THREE DISTINCT EFFORTS: 1) SUPPORT STARBUCKS COMMISSIONING AGENT (CXA) DURING INSTALLATION VERIFICATION AND CORRECT DISCLOSED DEFICIENCIES; 2) PERFORM TESTING, ADJUSTING, BALANCING AND SYSTEM STARTUP AND SUPPORT FUNCTIONAL PERFORMANCE TESTING BY STARBUCKS CXA; 3) CORRECT DEFICIENCIES DISCLOSED BY FUNCTIONAL PERFORMANCE TESTING AND SUBMIT REPORTS. CONTRACTOR SHALL PERFORM AND PROVIDE THE FOLLOWING: A. SYSTEMS SUBJECT TO COMMISSIONING MAY INCLUDE, BUT ARE NOT LIMITED TO DOMESTIC HOT WATER GENERATION, HVAC SYSTEMS, ROOFTOP UNITS, EXHAUST FANS, HVAC CONTROLS, LIGHTING CONTROLS, AIR CURTAINS, BUILT -IN REFRIGERATION EQUIPMENT, AND RENEWABLE ENERGY SYSTEMS. B. CONTRACTORex SHALL INCLUDE COMMISSIONING ACTIVITIES IN PROJECT SCHEDULE AND SHOW INTERVALS FOR PERFORMANCE OF WORK FOR WHICH CONTRACTOR IS RESPONSIBLE AND INTERVALS FOR WORK PERFORMED BY STARBUCKS- CXA. CONTRACTOR SHALL SHOW RESOURCES FOR PERFORMING ALL WORK RELATED TO COMMISSIONING ACTIVITIES ON A LINE ITEM IN THE SCHEDULE OF VALUES. C, CONTRACTOR SHALL INSTALL EQUIPMENT IN ACCORDANCE WITH THE MANUFACTURER'S REQUIREMENTS AND ALL CONTRACT DOCUMENTS. ENSURE THAT ALL EQUIPMENT IS INSTALLED TOTALLY COMPLETE, AND ACCESSIBLE TO STARBUCKS CXA FOR INSTALLATION VERIFICATION AND FUNCTIONAL PERFORMANCE TESTING PRIOR TO THE SCHEDULED START OF INSTALLATION VERIFICATION. D. INSTALLATION VERIFICATION SHALL BE PERFORMED BY STARBUCKS' CXA. CONTRACTOR SHALL SUPPORT STARBUCKS CXA INSTALLATION VERIFICATION EFFORTS AS NECESSARY. PROVIDE ALL ACCESS AND EQUIPMENT NECESSARY FOR STARBUCKS STAFF TO VERIFY THAT THE EQUIPMENT IS INSTALLED CORRECTLY. E. CONTRACTOR SHALL BE READILY AVAILABLE DURING INSTALLATION VERIFICATION TO CORRECT ANY DEFICIENCIES OR DEFECTS DISCLOSED BY THE INSTALLATION VERIFICATION PROCESS. CORRECTIONS SHALL BE MADE IN A TIMELY MANNER WITHOUT DISRUPTION OF THE CONSTRUCTION SCHEDULE. F. ALL HVAC, EXHAUST FAN, AND AIR CURTAIN EQUIPMENT SHALL BE TESTED, ADJUSTED AND BALANCED BY THE CONTRACTOR'S TESTING, ADJUSTING AND BALANCE AGENT (SEE TESTING, ADJUSTING AND BALANCING) AFTER THE SYSTEM IS VERIFIED TO BE COMPLETE AND CORRECT BY STARBUCKS CXA, IN ACCORDANCE WITH THE REQUIREMENTS OF THESE DOCUMENTS. ALL HVAC CONTROL SYSTEMS SHALL BE TESTED TO ENSURE THAT CONTROL DEVICES, COMPONENTS, EQUIPMENT AND SYSTEMS ARE CALIBRATED, ADJUSTED AND OPERATE IN ACCORDANCE WITH THESE PLANS AND SPECIFICATIONS. SEQUENCES OF OPERATION SHALL BE TESTED TO ENSURE THAT THEY OPERATE IN ACCORDANCE WITH THE CONTRACT REQUIREMENTS. DELIVERABLES: PRELIMINARY, WRITTEN TESTING AND AIR BALANCE REPORT CONFORMING TO THE REQUIREMENTS SPECIFIED HEREIN, DOCUMENTING THE INFORMATION SPECIFIED, ETC. TO THE STARBUCKS CXA IMMEDIATELY UPON COMPLETION OF THE WORK. G. CONTRACTOR SHALL INFORM STARBUCKS CXA WHEN EQUIPMENT IS READY FOR FUNCTIONAL PERFORMANCE TESTING. ALL EQUIPMENT SHALL BE READY FOR FUNCTIONAL PERFORMANCE TESTING PRIOR TO STARTING TESTING, CONTRACTOR SHALL OPERATE EQUIPMENT FOR STARBUCKS CXA AND VERIFY BY DEMONSTRATION THE CORRECT OPERATION OF EQUIPMENT, RESPONSE OF SENSORS, AND PROPER EXECUTION OF HVAC CONTROL AND UGHTING SEQUENCES; INCLUDING BUT NOT LIMITED TO, AIR MOVEMENT, TEMPERATURE, SOUND, AND CONTROL RESPONSE. PROVIDE ANY SECURITY ACCESS, HARDWARE, SOFTWARE, OR OTHER SUPPORT AS NEEDED FOR THE STARBUCKS CXA TO EFFICIENTLY WITNESS AND DOCUMENT ALL EQUIPMENT TESTING. STARBUCKS CXA WILL RECORD THE EQUIPMENT OPERATION AND RESPONSE TO TESTING SEQUENCES AND PREPARE A LIST OF ANY DEFICIENCIES DISCLOSED BY THE FUNCTIONAL PERFORMANCE TESTS FOR CORRECTION BY THE CONTRACTOR. EQUIPMENT INCLUDES, BUT IS NOT LIMITED TO, AIR HANDLING UNITS, ROOFTOP AND SPLIT TYPE, CONDENSING UNITS, EXHAUST FANS, LIGHTING CONTROLS, ETC. DELIVERABLES: PROVIDE COMPLETED COPIES OF ALL START UP REPORTS, FILLED OUT ON THE MANUFACTURERS' FORMS, TO THE STARBUCKS CXA. H. CONTRACTOR IS RESPONSIBLE FOR CORRECTING ANY ISSUES OR DEFICIENCIES DISCLOSED DURING THE FUNCTIONAL PERFORMANCE TESTING PROCESS. CORRECTIONS SHOULD BE MADE IN A TIMELY MANNER WITHOUT DISRUPTION TO THE SYSTEM AND CONSTRUCTION SCHEDULE. I. CONTRACTOR SHALL BE READILY AVAILABLE FOR ANY RE- TESTING OF EQUIPMENT DEEMED NECESSARY BY STARBUCKS CXA DURING INSTALLATION VERIFICATION AND FUNCTIONAL PERFORMANCE TESTING. CONTRACTOR IS RESPONSIBLE FOR CORRECTING ANY ISSUES OR DEFICIENCIES FOUND IN THE SYSTEM DURING ANY AND ALL RE- TESTING. CORRECTIONS SHOULD BE MADE IN A TIMELY MANNER WITHOUT DISRUPTION TO THE SYSTEM AND CONSTRUCTION SCHEDULE. DELIVERABLES: FINAL BALANCE REPORT, DEFICIENCIES LIST NOTING CORRECTIVE ACTIONS PERFORMED BY CONTRACTOR IN RESPONSE TO INSTALLATION VERIFICATION AND FUNCTIONAL PERFORMANCE TEST RESULTS. J. CONSTRUCTION AND POST CONSTRUCTION TESTING: ADDITIONAL TESTING MAY BE REQUIRED BY LEED AND OTHER PROCESSES THAT MAY OCCUR OUT OF SEQUENCE WITH COMMISSIONING SERVICE. CONTRACTOR SHALL CONDUCT, DOCUMENT, SUPPORT AND SCHEDULE THIS TESTING AS DIRECTED BY STARBUCKS CXA. 1 UO7 63 REVIEWED FOR CODE APPR01�Ei� COMPLIANCE AUG 1 g 2011 City of Tukwila BUILDING DIVISION RECEIVED AUG 16 2011 PERMIT CENTEE Starbucks Coffee Company 2401 Utah Avenue South Seattle, Washington 98134 (206) 318 -1575 These Drawings and Specifications are confidential and shall remain the sole property of Starbucks Corporation. They shalt not be reproduced (in whole or in part), shared with third parties or used in any manner on other projects or extensions to this project without the prior written consent of Starbucks Corporation. These drawings and specifications are Intended to express Design Intent for a prototypical Starbucks store (which is subject to change at anytime) and do not reflect actual site conditions. Neither party shall have any obligation nor liability to the other (except as stated above) until a written agreement is fully executed by both parties. RENO H ENaINEINRUNa 111 AVE. C SUITE 104, SNOHOMISH, 98290 PH: 360.8834677 M: 425. 949.6099 rensch.engineering @ comcast.net Revision Schedule Rev Date By Description 1 05/27/11 Ext. Lighting Addition r igije L t- uurebb. 3301 S. Norfolk St. Tukwila, WA 98168 Store #: Project #: Issue Date: Sbux Design Manager. Designed by: Drawn by: Checked by: TBD 5/2/11 Anthony Perez Chris Rensch Yumi Roth Chris Rensch Sheet Tit Scale: Electrical Panel Schedules & One -Line Diagram Sheet Number: E -002 P INSTALL CONDUIT UNDERGROUND TO MAIN BUILDING W/ GND WIRE PER CODE. ■nwm���∎ ∎ice ∎r ■-■■r ■���.�� W∎''i STORAGE UNIT POWER PLAN CONFIRM LAYOUT & RECEPTACLE MOUNTING FOR ALL DT POS EQUIPMENT. fIMIINNWOPY 4IIIUV '15 �3if9 ii'', 38 Eit.149,11 CD l'r otnii . mrarap iii-40 110191 Ilii12§1 B -26,2 B -31,33 A -11,13 INSTALLATION NOTES: 2. SURFACE MOUNT ALL RACEWAYS, J— BOXES & RECEPTACLES. COORDINATE ROUTES 8c SPACE CONDITIONS WITH OTHER TRADES & STARBUCKS CM. 3. ALL SURFACE MOUNTED RACEWAYS ABOVE COUNTERS, ON WALLS & CEILINGS SHALL BE TYPE EMT CONDUIT. RACEWAYS BELOW COUNTER MAY BE MC CABLE WHERE APPROPRIATE. 4. MOUNT CONDUITS TO UNISTRUT MOUNTS (AS TIGHT AS POSSIBLE). 5. ALL LOW VOLTAGE WIRING SHALL BE ROUTED IN CONDUIT. CONFIRM REQUIREMENTS WITH VENDORS. 6. SEE E -501 MENU BOARD DETAILS FOR ADDITIONAL SITE POWER REQUIREMENTS. UNDERGROUND SERVICE LATERAL (COORD. W/ LL) CT CAN & METER (COORD Wf LL & SEE RISER). B -35,37 PANELS A &B A -23,25 A -15,17 ` A -27,29 A -19,21 B -10,12 B- 16,18,20 A- 14,36,38 J - I I HOT BOX FOR WATER SERVICE. CONFIRM LOCATION & REQUIREMENTS. B -2 2 #10, 3/4 "C W/ GND Iv `" T T 1 1 1 J L J POWER PLAN 0 1 2 3 4 12 GENERAL POWER NOTES POWER PLAN KEY NOTES PROVIDE ALL BRANCH CIRCUITING AND DEVICES, EVEN IF NOT SHOWN. PROVIDE ALL WIRING AND WIRE QUANTITIES TO ACCOMPLISH CIRCUITING TO MEET SPEC REQUIREMENTS AND APPUCABLE CODES. ALL 1S NEW UNLESS OTHERWISE NOTED. WIRE QUANTITIES ARE NOT SHOWN. FURNISH & INSTALL PER NOTES, CODE AND AS NEEDED WITH DEDICATED NEUTRALS FOR ALL GFI BREAKER PROTECTED CIRCUITS (TO PREVENT FALSE TRIPS). INSTALL A NEUTRAL CONDUCTOR FOR ALL CIRCUITS INCLUDING 208V 1 —PHASE LOADS TO ALLOW FOR CONTROL POWER AND FOR FUTURE UPGRADES. nl NOT ALL CONDUITS /CIRCUITS CALLED FOR IN NOTES ARE SHOWN IN PLAN `v.:1 VIEW. Q VERIFY ALL EQUIPMENT RATINGS IN FIELD AND ADJUST CIRCUIT BREAKER RATINGS AS MAY BE NEEDED. CONFIRM CIRCUIT VOLTAGE IS AT A VOLTAGE RECOMMENDED BY EQUIPMENT MANUFACTURERS. IF NEEDED, THE CONTRACTOR SHALL PROVIDE AND INSTALL BUCK —BOOST TRANSFORMERS TO BE LOCATED IN ACCESSIBLE LOCATIONS ABOVE THE CEILING WITHIN 6' OF THE ELECTRICAL PANEL. IF LOCAL CODES DO NOT ALLOW INSTALLATION ABOVE THE CEILINGS, THE TRANSFORMERS SHALL BE MOUNTED TO THE WALL JUST BELOW THE CEILING. ACCEPTABLE TRANSFORMERS INCLUDE ACME. FURNISH AND INSTALL ANY ADDITIONAL O.C.P. NEEDED. SEE ARCH. SHEETS FOR PAINTING AND COLORS FOR ANY EXPOSED J— BOXES, CONDUIT, ETC. 0 VERIFY ACTUAL RATINGS /LISTINGS OF EQUIPMENT AND ADJUST BREAKER, OUTLET & CIRCUIT SIZES/RATINGS AS MAY BE NEEDED PER CODE. (H IF ANY CORD AND PLUG IS OBSTRUCTED BY CABINET PARTITIONS, PROVIDE '' ADDITIONAL OUTLET. 1110) 0 j Description 1 J - I I HOT BOX FOR WATER SERVICE. CONFIRM LOCATION & REQUIREMENTS. B -2 2 #10, 3/4 "C W/ GND Iv `" T T 1 1 1 J L J POWER PLAN 0 1 2 3 4 12 GENERAL POWER NOTES POWER PLAN KEY NOTES PROVIDE ALL BRANCH CIRCUITING AND DEVICES, EVEN IF NOT SHOWN. PROVIDE ALL WIRING AND WIRE QUANTITIES TO ACCOMPLISH CIRCUITING TO MEET SPEC REQUIREMENTS AND APPUCABLE CODES. ALL 1S NEW UNLESS OTHERWISE NOTED. WIRE QUANTITIES ARE NOT SHOWN. FURNISH & INSTALL PER NOTES, CODE AND AS NEEDED WITH DEDICATED NEUTRALS FOR ALL GFI BREAKER PROTECTED CIRCUITS (TO PREVENT FALSE TRIPS). INSTALL A NEUTRAL CONDUCTOR FOR ALL CIRCUITS INCLUDING 208V 1 —PHASE LOADS TO ALLOW FOR CONTROL POWER AND FOR FUTURE UPGRADES. nl NOT ALL CONDUITS /CIRCUITS CALLED FOR IN NOTES ARE SHOWN IN PLAN `v.:1 VIEW. Q VERIFY ALL EQUIPMENT RATINGS IN FIELD AND ADJUST CIRCUIT BREAKER RATINGS AS MAY BE NEEDED. CONFIRM CIRCUIT VOLTAGE IS AT A VOLTAGE RECOMMENDED BY EQUIPMENT MANUFACTURERS. IF NEEDED, THE CONTRACTOR SHALL PROVIDE AND INSTALL BUCK —BOOST TRANSFORMERS TO BE LOCATED IN ACCESSIBLE LOCATIONS ABOVE THE CEILING WITHIN 6' OF THE ELECTRICAL PANEL. IF LOCAL CODES DO NOT ALLOW INSTALLATION ABOVE THE CEILINGS, THE TRANSFORMERS SHALL BE MOUNTED TO THE WALL JUST BELOW THE CEILING. ACCEPTABLE TRANSFORMERS INCLUDE ACME. FURNISH AND INSTALL ANY ADDITIONAL O.C.P. NEEDED. SEE ARCH. SHEETS FOR PAINTING AND COLORS FOR ANY EXPOSED J— BOXES, CONDUIT, ETC. 0 VERIFY ACTUAL RATINGS /LISTINGS OF EQUIPMENT AND ADJUST BREAKER, OUTLET & CIRCUIT SIZES/RATINGS AS MAY BE NEEDED PER CODE. (H IF ANY CORD AND PLUG IS OBSTRUCTED BY CABINET PARTITIONS, PROVIDE '' ADDITIONAL OUTLET. RECEPTACLES AND FACEPLATE COLORS SHALL BE: BAR AREA: STAINLESS STEEL PLATES WITH WHITE OUTLETS. WORKROOM AREA: STAINLESS STEEL PLATES WITH WHITE OUTLETS. 1 ENTRY MONUMENT SIGN ( COORD. W/ ARCH. & SITE PLANS) 2 #10, 3/4 "C W/ GND 0 0 0 ELECTRIC HOT WATER HEATER (9KW — 208V/10). 2#6 CU. W/ GND IN 3/4 "C. RETAIL GRINDER/ SCALE: PROVIDE 4 —PLEX RECEPTACLE 0 26" AFF. TWIN BREWER: NEMA 14-50R RECEPTACLE 0 26" AFF, 3/4 "C -3#6 AND 410 GROUND, CONTRACTOR TO PROVIDE A NEMA 14 -50P CORD CAP FOR THE BREWER, BRYANT OR EQUAL. 0 FOR ESPRESSO MACHINE, FURNISH AND INSTALL NEMA 6 -50R RECEPTACLE HUBBELL HBL9367 SERIES OR EQUAL AT 30" AFF. ROUTE 3/4" CONDUIT — (2) #6 AND (1) #10 GROUND FROM MACHINE BACK TO PANEL. FURNISH AND INSTALL NEMA 6 -50P ANGLED PLUG, HUBBELL HBL9368 SERIES OR EQUAL UNDER COUNTER REFRIGERATOR: PROVIDE RECEPTACLE 0 26" AFF. REFRIGERATOR AND /OR FREEZER: RECEPTACLE AT 84" AFF. ICE MACHINE (AIR COOLED): PROVIDE RECEPTACLE AND POWER CONNECTION PER MANUFACTURER / CODE REQUIREMENTS. CONFIRM MOUNTING HEIGHT. 0 SURFACE MOUNTED ELECTRIC FAN FORCED WALL HEATER WITH INTEGRAL THERMOSTAT. KING 'AWS -12 W/ PT -1 STAT (750W -120V) 0 DISHWASHER (HIGH TEMP): NEMA 14 -50R RECEPTACLE 0 18" AFF, 3/4 "C — 3#6 AND 1110 GROUND. 0 NOTE NOT USED. 11 NOTE NOT USED. 12 COFFEE WARMERS: PROVIDE RECEPTACLE(S) 0 26" AFF. -13 BLENDERS: RECEPTACLES 0 48" AFF IN 2 DUPLEX BOXES. 0 Q 14 17 NOTE NOT USED. NOTE NOT USED. 18 SAFE: FURNISH AND INSTALL DUPLEX RECEPTACLE AND SECURITY J —BOX AT 18" AFF. GC TO F &I CABLING AND COORDINATE WTH DIEBOLD FOR SAFE INSTALLATION & SETUP. 0 HOT TAP: PROVIDE RECEPTACLE AT 26" AFF. 20 NOTE NOT USED. 21 EXHAUST FAN: FAN SHALL RUN CONTINUOUSLY. (COORDINATE WITH MECHANICAL). 22 MANAGER'S DESK: PROVIDE LAN / POS / ELECTRICAL DEVICES. SEE DETAILS ON E -501 FOR LOCATIONS AND REQUIREMENTS. ALL REQUIRED OUTLETS ARE NOT NECESSARILY SHOWN. 23 25 NOTE NOT USED. NOTE NOT USED. 2 ALARM KEYPAD AND EMERGENCY CALL PHONE: MOUNT 0 54" AFF. ROUTE CONDUIT FROM J —BOX TO SECURITY PANEL. 27 NOTE NOT USED. 0 NOTE NOT USED. 29 DUPLEX CONVENIENCE OUTLET 0 18 "AFF. 30 PHONE PANEL ABOVE CEILING (CONFIRM LOCATION). PROVIDE ADJACENT 4 —PLEX RECEPTACLE. NOTE NOT USED. 31 33 NOTE NOT USED. 34 CUP LABELER: PROVIDE ISOLATED GROUND RECEPTACLE AND BACKBOX FOR LAN CONNECTION 0 26" AFF. 35 NOTE NOT USED. I v%, -07 36 NOTE NOT USED. - 37 WARMING OVEN REFRIGERATOR: F &I 120V POWER RECEPTACLE 028 "AFF. MATCH RECEPTACLE /CIRCUIT RATING WITH EQUIPMENT UL RATING (CONFIRM). 38 WARMING OVEN: FURNISH & INSTALL NEMA 6 -30R RECEPTACLE 0 28" AFF, & ALL NECESSARY CONDUIT, WIRE ( #10CU., THWN) & CONNECTIONS BACK TO SERVING PANEL. NOTE NOT USED. D/T AUTOMATIC SLIDER WINDOW: PROVIDE (1) CONDUIT AND J —BOX WITH 120V, 20A BRANCH CIRCUIT. SEE MANUFACTURER'S SPECIFICATIONS FOR REQ. 41 WARMING OVEN DATA: F &I FLUSH DATA OUTLET 028 "AFF AND CAT5 DATA CABLE FROM OUTLET BACK TO DATA RACK. D/T MISC. POS EQUIPMENT: PROVIDE A 4 —PLEX RECEPTACLE 0 26" AFF. D/T COMM. BASE UNIT / CCTV MONITOR / MONITOR: PROVIDE (2) DUPLEX RECEPTACLES WITH 120V, 20A DEDICATED GROUND CIRCUIT. SEE ARCH DETAILS FOR MOUNTING HEIGHTS. 0 D/T COMMUNICATION / CCTV SYSTEM: PROVIDE RECEPTACLES AND (3) J— BOXES. J —BOX #1 (BELOW COUNTER HEIGHT): INTERCEPT CONDUIT FROM DRIVE —THRU OCS SPEAKER POST OR MENU BOARD SPEAKER LOCATION AND - REAR BUILDING CCTV CAMERA, PROVIDE 2 —GANG J —BOX AND ROUTE A 1" CONDUIT UP TO CCTV BOX. J —BOX #2 (CCTV MONITOR HEIGHT): INTERCEPT CONDUIT FROM J —BOX #1, AND ROUTE A 1" CONDUIT UP TO WIRELESS BASE SYSTEM J —BOX. J —BOX #3 (WIRELESS BASE SYSTEM HEIGHT): INTERCEPT CONDUIT FROM J —BOX #2. (CONDUITS NOT SHOWN): SEE DETAIL ON E -501. 45 NOTE NOT USED. 46 D/T REGISTER AND EXPEDITOR REGISTER: PROVIDE RECEPTACLE AND DATA OUTLET AT 26" AFF. ROUTE 3/4" DATA CONDUIT BACK TO DATA RACK. 0 REVIEWED FOR CODE COMPLIANCE APPROVED AUG 1 g 2011 City of Tukwila BUILDING DIVISION RECEIVED AUG 16 2011 PERMIT CENTER Starbucks Coffee Company 2401 Utah Avenue South Seattle, Washington 98134 (206) 318 -1575 These Drawings and Specifications are confidential and shall remain the sole property of Starbucks Corporation. They shall not be reproduced (in whole or in part), shared with third parties or used in any manner on other projects or extensions to this project without the prior written consent of Starbucks Corporation. These drawings and specifications are intended to express Design Intent for a prototypical Starbucks store (which is subject to change at anytime) and do not reflect actual site conditions. Neither party shall have any obligation nor liability to the other (except as stated above) until a written agreement is fully executed by both parties. FIENH ENQINE1EPIINQ 111 AVE. C SUITE 104, SNOHOMISH, 98290 PH: 360.86346877 Mt 425- 9494099 rensch.engineeringecomcast.net Revision Schedule IMPORTANT GFI AND CIRCUIT NOTES: ALL 120V OUTLETS IN BACK BAR, FRONT BAR, WORKROOM (AND AS DEFINED BY INSPECTOR & AHJ) AND AS INDICATED ELSEWHERE SHALL BE GFI PROTECTED. GFCI RECEPTACLES ARE ONLY ALLOWED WHERE SHOWN IN PLAN. ALL OTHER GFCI PROTECTED CIRCUITS SHALL BE PROTECTED BY GFI BREAKERS. Description RECEPTACLES AND FACEPLATE COLORS SHALL BE: BAR AREA: STAINLESS STEEL PLATES WITH WHITE OUTLETS. WORKROOM AREA: STAINLESS STEEL PLATES WITH WHITE OUTLETS. 1 ENTRY MONUMENT SIGN ( COORD. W/ ARCH. & SITE PLANS) 2 #10, 3/4 "C W/ GND 0 0 0 ELECTRIC HOT WATER HEATER (9KW — 208V/10). 2#6 CU. W/ GND IN 3/4 "C. RETAIL GRINDER/ SCALE: PROVIDE 4 —PLEX RECEPTACLE 0 26" AFF. TWIN BREWER: NEMA 14-50R RECEPTACLE 0 26" AFF, 3/4 "C -3#6 AND 410 GROUND, CONTRACTOR TO PROVIDE A NEMA 14 -50P CORD CAP FOR THE BREWER, BRYANT OR EQUAL. 0 FOR ESPRESSO MACHINE, FURNISH AND INSTALL NEMA 6 -50R RECEPTACLE HUBBELL HBL9367 SERIES OR EQUAL AT 30" AFF. ROUTE 3/4" CONDUIT — (2) #6 AND (1) #10 GROUND FROM MACHINE BACK TO PANEL. FURNISH AND INSTALL NEMA 6 -50P ANGLED PLUG, HUBBELL HBL9368 SERIES OR EQUAL UNDER COUNTER REFRIGERATOR: PROVIDE RECEPTACLE 0 26" AFF. REFRIGERATOR AND /OR FREEZER: RECEPTACLE AT 84" AFF. ICE MACHINE (AIR COOLED): PROVIDE RECEPTACLE AND POWER CONNECTION PER MANUFACTURER / CODE REQUIREMENTS. CONFIRM MOUNTING HEIGHT. 0 SURFACE MOUNTED ELECTRIC FAN FORCED WALL HEATER WITH INTEGRAL THERMOSTAT. KING 'AWS -12 W/ PT -1 STAT (750W -120V) 0 DISHWASHER (HIGH TEMP): NEMA 14 -50R RECEPTACLE 0 18" AFF, 3/4 "C — 3#6 AND 1110 GROUND. 0 NOTE NOT USED. 11 NOTE NOT USED. 12 COFFEE WARMERS: PROVIDE RECEPTACLE(S) 0 26" AFF. -13 BLENDERS: RECEPTACLES 0 48" AFF IN 2 DUPLEX BOXES. 0 Q 14 17 NOTE NOT USED. NOTE NOT USED. 18 SAFE: FURNISH AND INSTALL DUPLEX RECEPTACLE AND SECURITY J —BOX AT 18" AFF. GC TO F &I CABLING AND COORDINATE WTH DIEBOLD FOR SAFE INSTALLATION & SETUP. 0 HOT TAP: PROVIDE RECEPTACLE AT 26" AFF. 20 NOTE NOT USED. 21 EXHAUST FAN: FAN SHALL RUN CONTINUOUSLY. (COORDINATE WITH MECHANICAL). 22 MANAGER'S DESK: PROVIDE LAN / POS / ELECTRICAL DEVICES. SEE DETAILS ON E -501 FOR LOCATIONS AND REQUIREMENTS. ALL REQUIRED OUTLETS ARE NOT NECESSARILY SHOWN. 23 25 NOTE NOT USED. NOTE NOT USED. 2 ALARM KEYPAD AND EMERGENCY CALL PHONE: MOUNT 0 54" AFF. ROUTE CONDUIT FROM J —BOX TO SECURITY PANEL. 27 NOTE NOT USED. 0 NOTE NOT USED. 29 DUPLEX CONVENIENCE OUTLET 0 18 "AFF. 30 PHONE PANEL ABOVE CEILING (CONFIRM LOCATION). PROVIDE ADJACENT 4 —PLEX RECEPTACLE. NOTE NOT USED. 31 33 NOTE NOT USED. 34 CUP LABELER: PROVIDE ISOLATED GROUND RECEPTACLE AND BACKBOX FOR LAN CONNECTION 0 26" AFF. 35 NOTE NOT USED. I v%, -07 36 NOTE NOT USED. - 37 WARMING OVEN REFRIGERATOR: F &I 120V POWER RECEPTACLE 028 "AFF. MATCH RECEPTACLE /CIRCUIT RATING WITH EQUIPMENT UL RATING (CONFIRM). 38 WARMING OVEN: FURNISH & INSTALL NEMA 6 -30R RECEPTACLE 0 28" AFF, & ALL NECESSARY CONDUIT, WIRE ( #10CU., THWN) & CONNECTIONS BACK TO SERVING PANEL. NOTE NOT USED. D/T AUTOMATIC SLIDER WINDOW: PROVIDE (1) CONDUIT AND J —BOX WITH 120V, 20A BRANCH CIRCUIT. SEE MANUFACTURER'S SPECIFICATIONS FOR REQ. 41 WARMING OVEN DATA: F &I FLUSH DATA OUTLET 028 "AFF AND CAT5 DATA CABLE FROM OUTLET BACK TO DATA RACK. D/T MISC. POS EQUIPMENT: PROVIDE A 4 —PLEX RECEPTACLE 0 26" AFF. D/T COMM. BASE UNIT / CCTV MONITOR / MONITOR: PROVIDE (2) DUPLEX RECEPTACLES WITH 120V, 20A DEDICATED GROUND CIRCUIT. SEE ARCH DETAILS FOR MOUNTING HEIGHTS. 0 D/T COMMUNICATION / CCTV SYSTEM: PROVIDE RECEPTACLES AND (3) J— BOXES. J —BOX #1 (BELOW COUNTER HEIGHT): INTERCEPT CONDUIT FROM DRIVE —THRU OCS SPEAKER POST OR MENU BOARD SPEAKER LOCATION AND - REAR BUILDING CCTV CAMERA, PROVIDE 2 —GANG J —BOX AND ROUTE A 1" CONDUIT UP TO CCTV BOX. J —BOX #2 (CCTV MONITOR HEIGHT): INTERCEPT CONDUIT FROM J —BOX #1, AND ROUTE A 1" CONDUIT UP TO WIRELESS BASE SYSTEM J —BOX. J —BOX #3 (WIRELESS BASE SYSTEM HEIGHT): INTERCEPT CONDUIT FROM J —BOX #2. (CONDUITS NOT SHOWN): SEE DETAIL ON E -501. 45 NOTE NOT USED. 46 D/T REGISTER AND EXPEDITOR REGISTER: PROVIDE RECEPTACLE AND DATA OUTLET AT 26" AFF. ROUTE 3/4" DATA CONDUIT BACK TO DATA RACK. 0 REVIEWED FOR CODE COMPLIANCE APPROVED AUG 1 g 2011 City of Tukwila BUILDING DIVISION RECEIVED AUG 16 2011 PERMIT CENTER Starbucks Coffee Company 2401 Utah Avenue South Seattle, Washington 98134 (206) 318 -1575 These Drawings and Specifications are confidential and shall remain the sole property of Starbucks Corporation. They shall not be reproduced (in whole or in part), shared with third parties or used in any manner on other projects or extensions to this project without the prior written consent of Starbucks Corporation. These drawings and specifications are intended to express Design Intent for a prototypical Starbucks store (which is subject to change at anytime) and do not reflect actual site conditions. Neither party shall have any obligation nor liability to the other (except as stated above) until a written agreement is fully executed by both parties. FIENH ENQINE1EPIINQ 111 AVE. C SUITE 104, SNOHOMISH, 98290 PH: 360.86346877 Mt 425- 9494099 rensch.engineeringecomcast.net Revision Schedule Rev Date By Description 1 05/27/11 Ext. Lighting Addition Store #: Project #: Issue Date: Sbux Design Manager: Designed by: Drawn by: Checked by: TBD 5/2/11 Anthony Perez Chris Rensch Yumi Roth Chris Rensch Sheet Title: Power Plan Scale: Sheet Number: E -111 0143 4X014 (7) STORAGE UNIT LIGHTING PLAN POWER PANELS 11611 SEE E -111 FOR INSTALLATION NOTES. COMMISSIONING REQUIREMENTS THE CONTRACTOR SHALL FURNISH AND INSTALL LIGHTING CONTROLS AS INDICATED. TEST TO ENSURE THAT CONTROL DEVICES, COMPONENTS, EQUIPMENT AND SYSTEMS ARE CALIBRATED, ADJUSTED AND OPERATE IN ACCORDANCE WITH THESE PLANS AND SPECIFICATIONS. SEQUENCES OF OPERATION SHALL BE FUNCTIONALLY TESTED TO ENSURE THEY OPERATE IN ACCORDANCE WITH THESE PLANS AND SPECIFICATIONS WITH STARBUCKS AGENT PRESENT. A COMPLETE REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND FILED WITH STARBUCKS ALONG WITH A ONE PAGE NARRATIVE EXPLAINING HOW TO CONTROL THE SYSTEM FOR THE STORE PARTNERS. SEE E -002 FOR FURTHER REQUIREMENTS. GENERAL LIGHTING NOTES LIGHTING PLAN KEY NOTES ALL IS NEW UNLESS OTHERWISE NOTED. aCOORDINATE WITH GC AS TO WHOM IS TO PROVIDE ALL LIGHT FIXTURES AND LAMPS UNLESS NOTED OTHERWISE. 0 REFER TO ARCHITECTURAL PLANS FOR EXACT FIXTURE LOCATIONS. 0 NOTE NOT USED. �.E ALL LAMPING IN FOOD PREP AREAS SHALL BE SHATTERPROOF LAMPS IF THE FIXTURE DOES NOT HAVE A LENSE. F REFER TO ARCHITECTURAL PLANS FOR EXACT FIXTURE LOCATIONS. 0 CONDUCTOR QUANTITIES ARE NOT SHOWN. F &I PER CODE WITH SWITCHING AS INDICATED BY LElILR DESIGNATION, NOTE, OR LOCAL SWITCH. CONFIRM WIRING DIAGRAMS AND REQUIREMENTS OF ANY SPECIAL LIGHTING CONTROLS. 6) TIMING DEVICE FOR EXTERIOR LIGHTS AND SIGNAGE TO BE LOCATED ADJACENT TO POWER PANELS. SET TIMING DEVICE SO THAT SIGNAGE IS ON AT 5:00 AM AND OFF AT 1:O0AM (AT STARBUCKS DIRECTION) ON A 24HR /DAY LOCK ON CIRCUIT. (SEE DETAIL) (2.) LIGHTS IDENTIFIED WITH "NL" & EMERGENCY FIXTURES TO BE ON 24 HOUR PER DAY LOCK -ON CIRCUIT CONNECTED TO THE UNSWITCHED HOT LEG. 0 MOTION DETECTOR SWITCH MOUNTED 48" AFF. EXTERIOR BUILDING LIGHTS AT DRIVE -THRU WINDOW TO BE CONTROLLED BY TIMECLOCK. SEE TIMECLOCK DETAIL. L 5 CEILING MOUNTED OCCUPANCY SENSOR TO CONTROL LIGHTS A$ INDICATED. SET FOR 30 MINUTE DELAY OFF. coMOUNT FLUORESCENT LIGHTS IN UNIT ABOVE. SEE ARCH. DETAILS FOR REQUIREMENTS & MOUNTING POSITION. 0 SEE ARCH. PLANS FOR MOUNTING. LIGHTS CONTROLLED BY PE CELL. FIELD LOCATE PE CELL (NOT SHOWN) ON NORTH FACE OF BUILDING. 9 INSTALL LOW VOLTAGE UGHTS & TRANSFORMER PER CODE & MANUF. REQUIREMENTS. Lighting Fixture Schedule Design ID 1 Count 1 Description ( Responsibility 1 Bulb 1 Comments Ext. Lighting Addition 11519 4 Track - Rail Surface Mounted - 48in - Black VD 11443 Io ., LED 7W-R63 PAR20 or Equal Emergency Lighting Equipment 11611 I 1 'Emergency Exit Light - White I VD 'LED 5W Low Energy or Equal I Additional Fixtures X0140 2 4ft Lensed Surface Mount Fluorescent Lithonia #LB332MV -1/3 VD (3) 32w T8 Lamps - Elec. Ballast 93w Input X0141 1 4ft Lensed Surface Mount Fluorescent Lithonia #SB232MV- GEB1OIS VD a.. (2) 32w T8 Lamps - Elec. Ballast 64w Input X0142 1 4ft Lensed Surface Mount Fluorescent Lithonia #LB332MV- 1 /3 -EL VD (3) 32w T8 Lamps - Elec. Ballast 93w Input w/ Emergency Backup X0143 10 4ft lensed weatherproof Fluorescent Lithonia #DMW- 1- 48T8HC- MV- GEB101S ' 11 II• : — iiiiirri is ' idl It .. a ;, jI TIMECLOC_KF B-36 VIAI a:. ' '!` i! 410, ' 0 F &I Compatible 50VA Transformer _ ._ z I , :_. a a b , ■ 0 I -4 i b 60w A -Lamp 60w Maximum Input 11519 .... - • 4ft Fluorescent Strip w/ Wire Cage Lithonia #Z132MV- GEBIOIS ill ._ -.••••1111■. I -36 - :— L• X0147 'Ill rallir II VD STORAGE UNIT LIGHTING PLAN POWER PANELS 11611 SEE E -111 FOR INSTALLATION NOTES. COMMISSIONING REQUIREMENTS THE CONTRACTOR SHALL FURNISH AND INSTALL LIGHTING CONTROLS AS INDICATED. TEST TO ENSURE THAT CONTROL DEVICES, COMPONENTS, EQUIPMENT AND SYSTEMS ARE CALIBRATED, ADJUSTED AND OPERATE IN ACCORDANCE WITH THESE PLANS AND SPECIFICATIONS. SEQUENCES OF OPERATION SHALL BE FUNCTIONALLY TESTED TO ENSURE THEY OPERATE IN ACCORDANCE WITH THESE PLANS AND SPECIFICATIONS WITH STARBUCKS AGENT PRESENT. A COMPLETE REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND FILED WITH STARBUCKS ALONG WITH A ONE PAGE NARRATIVE EXPLAINING HOW TO CONTROL THE SYSTEM FOR THE STORE PARTNERS. SEE E -002 FOR FURTHER REQUIREMENTS. GENERAL LIGHTING NOTES LIGHTING PLAN KEY NOTES ALL IS NEW UNLESS OTHERWISE NOTED. aCOORDINATE WITH GC AS TO WHOM IS TO PROVIDE ALL LIGHT FIXTURES AND LAMPS UNLESS NOTED OTHERWISE. 0 REFER TO ARCHITECTURAL PLANS FOR EXACT FIXTURE LOCATIONS. 0 NOTE NOT USED. �.E ALL LAMPING IN FOOD PREP AREAS SHALL BE SHATTERPROOF LAMPS IF THE FIXTURE DOES NOT HAVE A LENSE. F REFER TO ARCHITECTURAL PLANS FOR EXACT FIXTURE LOCATIONS. 0 CONDUCTOR QUANTITIES ARE NOT SHOWN. F &I PER CODE WITH SWITCHING AS INDICATED BY LElILR DESIGNATION, NOTE, OR LOCAL SWITCH. CONFIRM WIRING DIAGRAMS AND REQUIREMENTS OF ANY SPECIAL LIGHTING CONTROLS. 6) TIMING DEVICE FOR EXTERIOR LIGHTS AND SIGNAGE TO BE LOCATED ADJACENT TO POWER PANELS. SET TIMING DEVICE SO THAT SIGNAGE IS ON AT 5:00 AM AND OFF AT 1:O0AM (AT STARBUCKS DIRECTION) ON A 24HR /DAY LOCK ON CIRCUIT. (SEE DETAIL) (2.) LIGHTS IDENTIFIED WITH "NL" & EMERGENCY FIXTURES TO BE ON 24 HOUR PER DAY LOCK -ON CIRCUIT CONNECTED TO THE UNSWITCHED HOT LEG. 0 MOTION DETECTOR SWITCH MOUNTED 48" AFF. EXTERIOR BUILDING LIGHTS AT DRIVE -THRU WINDOW TO BE CONTROLLED BY TIMECLOCK. SEE TIMECLOCK DETAIL. L 5 CEILING MOUNTED OCCUPANCY SENSOR TO CONTROL LIGHTS A$ INDICATED. SET FOR 30 MINUTE DELAY OFF. coMOUNT FLUORESCENT LIGHTS IN UNIT ABOVE. SEE ARCH. DETAILS FOR REQUIREMENTS & MOUNTING POSITION. 0 SEE ARCH. PLANS FOR MOUNTING. LIGHTS CONTROLLED BY PE CELL. FIELD LOCATE PE CELL (NOT SHOWN) ON NORTH FACE OF BUILDING. 9 INSTALL LOW VOLTAGE UGHTS & TRANSFORMER PER CODE & MANUF. REQUIREMENTS. Lighting Fixture Schedule Design ID 1 Count 1 Description ( Responsibility 1 Bulb 1 Comments Ext. Lighting Addition 11519 4 Track - Rail Surface Mounted - 48in - Black VD 11443 12 Track - Fixture Shrouded - Black VD LED 7W-R63 PAR20 or Equal Emergency Lighting Equipment 11611 I 1 'Emergency Exit Light - White I VD 'LED 5W Low Energy or Equal I Additional Fixtures X0140 2 4ft Lensed Surface Mount Fluorescent Lithonia #LB332MV -1/3 VD (3) 32w T8 Lamps - Elec. Ballast 93w Input X0141 1 4ft Lensed Surface Mount Fluorescent Lithonia #SB232MV- GEB1OIS VD (2) 32w T8 Lamps - Elec. Ballast 64w Input X0142 1 4ft Lensed Surface Mount Fluorescent Lithonia #LB332MV- 1 /3 -EL VD (3) 32w T8 Lamps - Elec. Ballast 93w Input w/ Emergency Backup X0143 10 4ft lensed weatherproof Fluorescent Lithonia #DMW- 1- 48T8HC- MV- GEB101S VD (1) 44w T8 HO Lamps - Elec. Ballast 46w Input X0144 2 Low Voltage MR16 Adj. Downlight - Bronze B -K #DSMR- 9BZP9B VD 50w MR16 - 60 °W Food F &I Compatible 50VA Transformer X0145 4 plus Site (note 2) Exterior Light - Coord. w/ Starbucks VD 60w A -Lamp 60w Maximum Input X0146 6 4ft Fluorescent Strip w/ Wire Cage Lithonia #Z132MV- GEBIOIS VD (1) 32w T8 Lamps - Elec. Ballast 32w Input w/ Symmetric Reflector & Wire Guard. X0147 7 LED Undercounter Task Light - 24in Bronze - CSL # ECL -24BZ VD 14.4w LED Per Fixture 15w input - w/ lea EWM -IBZ Hard Wire Connector w/ Switch & 18° BZ Linking Cords as needed. X0148 2 Low Voltage Adjustable/Recessed Downli • ht Bronze B -K #VS R7- BZP -9AJ VD 50w MR16 - 26° N Flood F &I Compatible 50VA Transformer X0149 dditiona Lig 9 Starbucks Custom Exterior Lighting ting Equipment VD 50w Metal Hallide 65w Input CL 1 Current Limiter for R series Track - Juno RCFL2IBL w/ TCL1 BL - Black VD lAmp Current Limiter -Black Lighting Schedule Notes: 1. Contractor shall coordinate with schedule and Starbucks to ensure that all light fixtures in food preparation areas are provided with shatter proof lamps or lenses. 2. See Site Plan & Architectural Details for additional fights. LIGHTING PLAN B -24 PER TIMECLOCK X0149 (2) DT ENTRY SIGN (COORD. W/ ARCH. & SITE PLANS) LtkO7 b3 REVIEWED FOR CODE COMPLIANCE APPROVED AUG 1 A 2011 City of Tukwila BUILDING DIVISION RECEIVED AUG 16 2011 PERMIT CENTER Starbucks Coffee Company 2401 Utah Avenue South Seattle, Washington 98134 (206) 318 -1575 These Drawings and Specifications are confidential and shall remain the sole property of Starbucks Corporation. They shall not be reproduced (in whole or in part), shared with third parties or used in any manner on other projects or extensions to this project without the prior written consent of Starbucks Corporation. These drawings and specifications are intended to express Design Intent for a prototypical Starbucks store (which is subject to change at anytime) and do not reflect actual site conditions. Neither party shall have any obligation nor liability to the other (except as stated above) until a written agreement is fully executed by both parties. RENSCH ENI INEER1ND ua 111 AVE. C SUITE 104, SNOHOMISH, 98290 PH: 3004634677 M: 425449 -6099 rensch.engineering0camcast.net Revision Schedule Rev Date By Description 1 05/27/11 Ext. Lighting Addition J 1 v. lJI MAIN vt. kwila, WA 98168 Store #: Project #: Issue Date: Sbux Design Manager Designed by: Drawn by: Checked by: TBD 5/2/11 Anthony Perez Chris Rensch Yumi Roth Chris Rensch Sheet Title: Scale: Lighting Plan Sheet Number E -112 r ACCESS PANEL COORD. W /GC #8, 3/4 "C B -1 1 A- 20,22,24 4 ! r I f ACCESS PANEL ( COORD. W /GC) LJ UPPER LEVEL POWER & LIGHTING PLAN 0 1 2 3 4 8 12 POWER PLAN KEY NOTES 0 MOTION SENSOR LIGHT SWITCH. 0 EXHAUST FAN: CONNECT TO TIMECLOCK (SEE DETAIL ON E -501). FAN SHALL RUN CONTINUOUSLY DURING OCCUPIED MODE. COORDINATE WITH MECHANICAL. 0 FURNISH AND INSTALL MAINTENANCE RECEPTACLE, LIGHT & SWITCH AS NEEDED FOR HVAC UNIT. (FIELD VERIFY BEST LOCATIONS). EL\tO7 63 REVIEWED FOR CODE COMPLIANCE APPROVED AUG 19 2011 City of Tukwila BUILDING DIVISION RECEIVED AUG 16 2011 PERMIT CENTER Starbucks Coffee Company 2401 Utah Avenue South Seattle, Washington 98134 (206) 318,1575 These Drawings and Specifications are confidential and shall remain the sole property of Starbucks Corporation, They shall not be reproduced (in whole or in part), shared with third parties or used in any manner on other projects or extensions to this project without the prior written consent of Starbucks Corporation. These drawings and specifications are intended to express Design Intent for a prototypical Starbucks store (which is subject to change at anytime) and do not reflect actual site conditions. Neither party shall have any-obligation nor liability to the other (except as stated above) until a written agreement is fully executed by both parties. REN88CH ENGIINEE INGI 111 AVE. C SUITE 104, SNOHOMISH, 98290 3604634677 M:425- 949.6099 rensch;englneering © comcast.net Revision Schedule Rev Date By Description rru=Uci I L1fUbb: 3301 S. Norfolk St. Tukwila, WA 98168 Store #: Project #: Issue Date: Sbux Design Manager: Designed by: Drawn by Checked by: TBD 5/2/11 Anthony Perez Chris Rensch Yumi Roth Chris Rensch Sheet Title: Scale: Upper Level Power & Lighting Plan Sheet Number: E -113 TELEPHONE LINES -2 CAT5 CABLES (BY OTHERS). T1 'HOTSPOT' LINE -1 CAT5 CABLE (BY OTHERS) DSL/FRAME RELAY LINE -1 CAT5 CABLE (BY OTHERS) DEDICATED POWER CIRCUIT TO PANEL DEDICATED POWER CIRCUIT TO PANEL J -BOX FOR 'HOTSPOT' T1 INTERNET CONNECTIONS- MOUNT 0 92" AFF. PROVIDE AN ORANGE COVER PLATE. J -BOX FOR TELECOMMUNICATION WIRING -MOUNT ABOVE CEILING, ROUTE BACK TO DEMARC PANEL (2) 1" EMT CONDUITS FOR SECURITY AND VIDEO PLENUM CABLES. SECURITY PANEL J -BOX -MOUNT 0 92" DEDICATED 1/2" EMT , - AFF & 15" OVER FROM ADJACENT DUPLEX. CONDUIT TO SECURITY PANEL J -BOX RECEPTACLE FOR MUSIC BLACKBOX. J -BOX FOR DSL/FRAME RELAY LINE -MOUNT 0 92" AFF. DUPLEX FOR SECURITY PANEL -MOUNT 0 92" AFF. QUADPLEX FOR SECURITY CAMERA POWER SUPPLIES -MOUNT 0 92" AFF. POWER CIRCUIT TO PANEL DUPLEX OUTLET FOR MUSIC SYSTEM SQUARE BOX FOR QUAD RECEPTACLE 12" AFF. J -BOX FOR (2) TELEPHONE JACKS. MANAGER'S STATION NOTES: 1) COORDINATE ALL J -BOX LOCATIONS WITH SECURITY VENDOR PRIOR TO ROUGH IN INCLUDING SECURITY PANEL SAFE, KEYPAD, STROBE, FRONT DOOR CAMERA, MOTION DETECTOR, MICROPHONE /SPEAKER, AND CAMERA. 2) COORDINATE "SECURITY J -BOX" AND "SECURITY STROBE J -BOX" LOCATIONS WITH SECURITY VENDOR PRIOR TO ROUGH -IN. 3) CONDUCTORS ARE NOT SHOWN. J -BOX FOR SECURITY KEYPAD. DUPLEX FOR SECURITY -MOUNT 0 48" AFF. DISPLAY MONITOR, CCTV, & COMM BASE POWER OUTLETS WORKSTATION DEDICATED DUPLEX (ORANGE) PLUG IN ONLY ISOBAR HERE -MOUNT 0 42" AFF. J BOX FOR POS TELEPHONE. 4 SQUARE BOX FOR LAN. REGISTER/EXPEDITOR POWER & DATA OUTLETS TO DT CAMERA TO SPEAKER POST COMM L}� VOLTAGE BASE J -BOX (TYP) POS STATION ccTv EXPEDITOR STATION -J CONFIRM MOUNTING HEIGHTS W /ARCH. SHEETS. J -BOX FOR POS TELEPHONE. DEDICATED DUPLEX FOR POS. LINE OF CEILING / / 1 ■ (IF PRESENT) ' I EACH C SAFE ARE (¢Y OTHERS) MOTION DETECTOR MICROPHONAMERA I E /SPEAKER OTHERS) (BY OTHERS) MISC. POS EQUIPMENT 4- SQUARE BOX FOR LAN. P TO IT RACK TO POWER PANELS POS STATION DEDICATED 1" EMT CONDUIT TO SECURITY PANEL J -BOX. DEDICATED 3/4" EMT CONDUIT TO SECURITY PANEL J -BOX. SECURITY STROBE J -BOX STROBE LOCATION J -BOX 3/4" EMT CONDUIT FRONT DOOR CAMERA J -BOX SECURITY J -BOX RECEPTACLES FOR CHECK VALIDATION & CASH DRAWERS J -BOX LOCATED ADJACENT TO SAFE DEDICATED DUPLEX OUTLET FOR SAFE (ORANGE) TO POWER PANELS DEDICATED CONDUIT — TO POWER PANELS DT POS LAN /POWER /PHONE/SECURITY SYSTEM DIAGRAM DT POS TO SECURITY PANEL J -BOX SAFE ASTRONOMIC (2 CHANNEL TIMESW ITCH, TORK fWZ201, SET TO TURN ON SIGNAGE/LIGHTING AT 5:00 AM AND OFF AT 1:00 AM (CONFIRM WITH STARBUCKS) AND TURN EXHAUST FAN ON /OFF WITH STORE HOURS. CONNECT TO 24 HRS /DAY LOCK ON CIRCUIT. B -36 B 1---r) RESTROOM EXHAUST FAN SIGNAGE/MENU BOARD /DT LIGHTS SIGNAGE AND EXHAUST FAN CONTROL DETAIL (WITH UPDATED TIMECLOCK SPEC) MAIN BONDING JUMPER TO NEUTRAL BUS GROUND BUS BOND TO BLDG. STEEL PER CODE. BUILDING STEEL SERVICE DISCONNECT SWITCH OR PANEL BOARD BOND TO METAL WATER PIPE. MAIN WATER SHUT -OFF VALVE BOND TO EQUIPMENT CONQCTORTYPIG ELECTRODE Riff-DAN AHJ) FOOTING 5' -0" MAX MAIN WATER SERVICE COPPER WATER LINE UNDERGROUND. CONNECT TO REBAR AT A CLEANED POINT WITH EXOTHERMIC WaELD. REBAR SHALL BE A MIN, i" DIA. AND 20 FT. IN LENGTH, ENCLOSED BY MIN, OF 2" OF CONCRETE. NOTES: 1. THIS DETAIL IS APPLICABLE WHEN STARBUCKS IS MODIFING AN EXISTING OR - INSTAWNG A NEW BUILDING SERVICE. IF MAIN BUILDING POWER SERVICE IS BY OTHERS, CONTRACTOR SHALL ENSURE GROUNDING SYSTEM INSTALLED BY OTHERS IS PER CODE. 2. GROUNDING ELECTRODE SYSTEM INSTALLATION SHALL BE IN STRICT COMPLIANCE WITH LOCAL CODES AND /OR AUTHORITIES HAVING JURISDICTION. 3. ALL GROUNDING ELECTRODE CONDUCTORS AND BONDING JUMPERS TO BE SIZED PER CODE. GROUNDING DETAIL NTS DETECTOR LOOP gENTERED ON SPEAKER POST 2 BELOW TOP OF ROADWAY. COORD. WITH 1 GENERAL SO THAT PAVEMENT 1 DOES NOT NEED TO BE CUT 1 FACE OF CONCRETE CURB TO PANELS S-- � CONCRETE FOOTING B -36 (TYP.) C" ONDUIT ONLY 1 S— DRIVE -THRU LANE SPEAKER POST: F &I J -BOX INSIDE SPEAKER POST AS NEEDED BOLLARD B -38 -� ir OUTLINE OF MENU " BOARD ABOVE MENU BOARD DETAIL NTS - EXACT ORIENTATION NOT SHOWN. SEE SITE PLAN & ARCH. DETAILS. TO L PREVIEW BOARD & DT SIGNAGE DETAIL GENERAL NOTES 0 PROVIDE A COMPLETE & OPERATING SYSTEM. ALL ITEMS ARE NOT NECESSARILY SHOWN. PROVIDE CORE DRILLS, CONCRETE CUTTING, UNDERGROUND BORING, AND PATCHING TO ROUTE RACEWAY(S) THROUGH FLOOR SLAB INTO WALLS AND THRU/BELOW EXISTING CONCRETE/PAVING. COORDINATE WITH STARBUCKS AND GENERAL CONTRACTOR TO DETERMINE SPECIFIC APPROVED METHODS AND EXACT LOCATIONS. 0 CONTRACTOR IS RESPONSIBLE FOR SITE INVESTIGATION PRIOR TO START OF WORK TO REVEAL THE FULL SCOPE OF WORK. D A LOCATING SERVICE SHALL BE USED TO LOCATE ALL EXISTING UNDERGROUND PIPES AND CONDUITS PRIOR TO TRENCHING. ri) REVIEW ALL CIVIL DRAWINGS AND COORDINATE TRENCHING ROUTES PRIOR TO TRENCHING. STARBUCKS CONTRACTOR IS RESPONSIBLE FOR ALL WORK NOT BEING FURNISHED AND INSTALLED BY LANDLORD'S CONTRACTOR (COORDINATE WITH GC & SEE WORKLETTER). cSEE ARCHITECTURAL SHEETS FOR SIGNAGE INFORMATION AND EXACT LOCATIONS. H FURNISH AND INSTALL PULL STRINGS IN ALL CONDUITS. ALL CONDUIT STUBS SHALL BE TYPE RMC CONDUIT WITH BUSHINGS. OTHER PORTIONS OF UNDERGROUND CONDUIT MAY BE PVC. (IF ALLOWED BY AHJ AND PER LOCAL CONDITIONS). ALL CONDUITS ABOVE GRADE SHALL BE EMT UNLESS OTHERWISE NOTED. NOTE NOT USED. 0 CONTRACTOR SHALL LABEL ALL CONDUITS SO THAT VENDORS WILL KNOW WHICH CONDUITS TO USE. F &I HAND HOLES WHERE NEEDED PER CODE AND TO INSTALL CABLE /WIRE. NOTE NOT USED. SEE E1.0 FOR LOW VOLTAGE CABLE AND SPECIFICATION REQUIREMENTS. 0 0 DETAIL KEY NOTES ; J SPEAKER POST POWER: FM 120V POWER FROM STARBUCKS POWER PANEL t:..1 1" UNDERGROUND CONDUIT VNTH 2 #10 & 1 #10 G, CU CONDUCTORS. DT SIGNAGE AND MENU BOARD: F &I 120V POWER FROM STARBUCKS PANEL(S) VIA STARBUCKS TIMECLOCK. 3/4" UNDERGROUND CONDUIT WITH 2 #10 & 1 #10 G, CU. 8 4 3 CONDUIT STUBBED UP THROUGH FOUNDATION. NOTE NOT USED. 8 6 5 NOTE NOT USED. SPEAKER POST DATA.. F &I 1" UNDERGROUND CONDUIT TO STARBUCKS "IT" RACK AND STUB IN WALL BEHIND RACK. 0 DETECTOR LOOP: STUB 3/4" UNDERGROUND CONDUIT FOR DETECTOR LOOP. SPEAKER POST AUDIO/VIDEO: ROUTE I" CONDUIT UNDERGROUND TO STARBUCKS DT P.O.S. AREA AT DT WINDOW FOR AUDIO/DETECTOR LOOP WIRING (SEPARATE CABLES - SAME CONDUIT). ELUO7 63 REVIEWED FOR CODE COMPLIANCE APPROVED AUG 1 . 2011 City of Tukwila BUILDING DIVISION RECEIVED AUG 16 2011 PERMITGENTgR 1 EXPIRES /, ?o er Starbucks Coffee Company 2401 Utah Avenue South Seattle, Washington 98134 (206) 318 -1575 These Drawings and Specifications are confidential and shall remain the sole property of Starbucks Corporation. They shall not be reproduced (in whole or in part), shared with third parties or used in any manner on other projects or extensions to this project without the prior written consent of Starbucks Corporation. These drawings and specifications are intended to express Design Intent for a prototypical Starbucks store (which is subject to change at anytime) and do not reflect actual site conditions. Neither party shall have any obligation nor liability to the other (except as stated above) until a written agreement is fully executed by both parties. REN$CH ENQINEERIN® 111 AVE. C SUITE 104, SNONOMISN, 98290 PHA 3804834677 Me 4259494099 rensch.englneering © comaastnet Revision Schedule Rev Date By Description r I VjGCA HuuIe��. 3301 S. Norfolk St. Tukwila, WA 98168 Store #: Project #: Issue Date: Sbux Design Manager: Designed by: Drawn by: Checked by: TBD 5/2/11 Anthony Perez Chris Rensch Yumi Roth Chris Rensch Sheet Title: Scale: Electrical Details Sheet Number: E -501