Loading...
HomeMy WebLinkAboutPermit EL11-0838 - WESTFIELD SOUTHCENTER MALL - LUSH FRESH HANDMADE COSMETICS88OT iria 11dY1i IILNIaDHLLf1OS L09 SDILLEIJ/\tSOD RLVJ'\tUNVFT HS3UJ HSfYI City of/Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206-431-3665 Web site: http: / /www.TukwilaWA.gov ELECTRICAL PERMIT Parcel No.: 9202470010 Address: 507 SOUTHCENTER MALL TUKW Project Name: LUSH FRESH HANDMADE COSMETICS Permit Number: Issue Date: Permit Expires On: EL11 -0838 11/02/2011 04/30/2012 Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA Contact Person: Name: MIKE SLEVIN Address: 8920 SHAUGNESSY ST , VANCOUVER CANADA Contractor: Name: HAGGARD ELECTRICAL CONTRACTORS LLC Address: 16702 65 AV SE , SNOHOMISH WA Contractor License No: HAGGAEC960DA Phone: 604 263 -6601 Phone: 425 - 949 -4004 Expiration Date: 03/01/2012 DESCRIPTION OF WORK: INTERIOR FINISH OUT (TENANT IMPROVEMENT) LIMITED TO 650 SF WITHIN LEASE SPACE IN EXISTING COVERED MALL Value of Electrical: NRES: $90,000.00 RES: $0.00 Type of Fire Protection: SPRINKLERS /AFA Electrical service provided by: PUGET SOUND ENERGY Fees Collected: National Electrical Code Edition: Permit Center Authorized Signature: T �', I hereby certify that I have read an• ex. governing this work will be compli: • with The granting of this permit does not construction or the performance of wor $1,821.75 2008 Date: u1\o24t ned this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. e to give authority to violate or cancel the provisions of any other state or local laws regulating authorized to sign and obtain this electrical permit. Signature: Print Name: Date: /7.-- 2 2 Gam/ This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/10 EL11 -0838 Printed: 11 -02 -2011 • 0 PERMIT CONDITIONS Permit No. EL11 -0838 * *ELECTRICAL ** 1: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 2: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 3: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 4: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 5: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 6: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. doc: EL -4/10 E L 11 -0838 Printed: 11 -02 -2011 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http: / /www. TukwilaWA. qov Electrical Permit No. Project No. -e-L oi$A.2 LP 61) ' (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: Tenant Name: 5 6 int 0 5 I Sc King Co Assessor's Tax No.: coPmF?t c S Property Owners Name: Fi e7.49 s LLC yl* !J1'l -N1 Suite Number: 0-40 Floor: 6>e New Tenant: Yes ❑ :.No Mailing Address: // 6 0 at'v/LC'fr�i� /3i 4.D, / /�'' vc-, 1-0 f cr9 City State (ao'zc Zip CONTACT PERSON - Who do we contact when your permit is ready to be issued Name: M ( - - 5'L- ' / N Mailing Address: 601 2 s- fw (1E- s,r'i Day Telephone: O 4` 3, 66 o ( S'7, t- t cOu *:2 4 V c3 Q = / Cam' E -Mail Address:_ `1.1 (u 1' /9 • City State Zip Fax Number: 63 o ¢__ 629 , l 8 G ELECTRICAL CONTRACTOR INFORMATION Company Name: h" TO ;7 Mailing Address: Contact Person: E -Mail Address: Contractor Registration Number: City Day Telephone: Fax Number: Expiration Date: State Zip Valuation of Project (contractor's bid price): $ No - S �/M �y-�c �d / e O -- Scope of Work (please provide detailed information): iN T�)' to / / 1/4 Si-( d v T (TE/vmN i I n4 f'/ o v /S/7 S 1,( "4 , 7 ' TO e O t W r"%f f/ /V LEASE S�° -e0 (• / N (7 CO '-"e)e --- . Will service be altered? ❑ Yes piNo Adding more than 50 amps? ❑ Yes yi No Type of Use:C` -7��fi Type of work: New ❑ Addition ❑ Service Change ❑ Remodel Tenant Improvement ❑ Low Voltage ❑ Generator V Fire Alarm ) Telecommunication ❑ Temporary Service Property Served by: ❑ Puget Sound Energy ❑ Seattle City Light H:\Applications\Forms- Applications On Line\2010 Applications \7 -2010 - Electrical Permit Applieation.doc bh Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings - - -- - - -- $152.85 (including an attached garage) ❑ Garages, pools, spas and outbuildings - $81.90 ea ❑ Low voltage systems (alarm, fitnnace thermostat) $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $81,90 (no added/altered circuits) ❑ Service change with added/altered circuits $81.90 number of added circuits $11:55 ea ❑ Circuits added/altered without service change $54:60 (up t� 5 circuits) ❑ Circuits added/altered without service change -- - $54.60 (6 or more circuits) $7.65 ea ❑ Meter /mast repair - $68. -25 ❑ Low voltage systems — - - - $59.85 (alarm, furnace thermostat) MULTI - FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract: MISCELLANEOUS FEES ❑ Temporary:service (residential) $63.00 ❑ Temporary service (generator) — - $78.75 ❑ Manufactured/Mobile home service $84:00 (excluding garage or outbuilding) ❑ Carnivals - -- $78.75 Number of concessions - $10.50 ea PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject t� possible revision by the Permit Center to comply with current fee schedules: Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation: The Building Official may grant one extension of time for an additional period not to exceed 90 days: The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: Date: 09/6 Vi Print Na : :I r 121 X SCUT r ?/W)_77712.- Day Telephone: 32=5— 5 7a- 3 19- Mailing Address :_Z "-' Jr O_ Ii4t/1%%0a= _ 73 W2 l - '7Zj121,tW /t-A- _ 'Wig 1 k /f$ City State Zip IDate Application Accepted: f ' I �y� I 1 Date Application Expires: H:Wpplicationa\Fonns- Applications On Line \2010 Applications \7 -2010 - Electrical Penmt Application.doc bh Page 2 of 2 Staff Initials: 1 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov RECEIPT Parcel No.: 9202470010 Permit Number: EL11 -0838 Address: 507 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 09/07/2011 Applicant: LUSH FRESH HANDMADE COSMETICS Issue Date: Receipt No.: R11 -02316 Initials: WER User ID: 1655 Payment Amount: $1,750.92 Payment Date: 10/21/2011 11:57 AM Balance: $0.00 Payee: LUSH COSMETICS TRANSACTION LIST: Type Method Descriptio Amount Payment Check 19512 1,750.92 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.00 ELECTRICAL PLAN - NONRES 000.345.832.00.00 Total: $1,750.92 1,457.40 293.52 doc: Receipt -06 Printed: 10 -21 -2011 Cit of Tukwila. 1 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: /hvww.ci.tukwila.wa.us SET RECEIPT RECEIPT NO: R11 -01950 Initials: JEM Payment Date: 09/07/2011 User ID: 1165 Total Payment: 1,074.21 Payee: LUSH COSMETICS LLC SET ID: S000001574 SET NAME: Tmp set/Initialized Activities SET TRANSACTIONS: Set Member Amount D11 -306 890.11 EL11 -0838 70.83 M11 -125 85.71 PG11 -133 27.56 TOTAL: 890.11 TRANSACTION LIST: Type Method Description Amount Payment Check 19367 1,074.21 TOTAL: 1,074.21 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES 000.345.832.00.0 70.83 PLAN CHECK - NONRES 000.345.830 1,003.38 TOTAL: 1,074.21 INSPECTION RECORD _ -62? Retain a copy with permit INSPECTION NO. PE MIT NO. CITY OF TUKWILA BUILDING DIVISION II' 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: �L'L Type of Inspection: � � — 71Jd FM/ 15 ra SN-0( sad Address: JD� oat. Date Called: fiX- r ' Special Instructions: Date Wanted:. r' �� � l I q..n m. Requester: Phone No: 56 Approved per applicable codes. Corrections required prior to approval. e� COMMENTS: — 71Jd FM/ 15 ra SN-0( sad 566 6u /- 075 fiX- r ' Inspector: A (� 'Date: 7.- 11 REINSPECTION FEE REQUIRED\ Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. •ERMIT COORD COPV PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL11 -0838 DATE: 09/07/11 PROJECT NAME: LUSH FRESH HANDMADE COSMETICS SITE ADDRESS: 507 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: Biding fivision Public Works Fire Prevention Structural Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete qi Incomplete DUE DATE: 09/08/11 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: • TUES/THURS ROUTING: Please Route REVIEWER'S INITIALS: Structural Review Required No further Review Required ri DATE: APPROVALS OR CORRECTIONS: DUE DATE: 10/06/11 Approved Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 Contractors or Tradespeople *ter Friendly Page • I Electrical Contractor A business licensed by LEI! to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company HAGGARD ELECTRICAL CONTRS LLC 3606689361 16702 65Th Ave Se Snohomish WA 98296 Snohomish Limited Liability Company UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 602357747 Active HAGGAEC960DA Electrical Contractor 3/1/2004 3/1/2012 General Unused Electrical Administrator INFORMATION License HAGGAR'964CL Name HAGGARD, RYAN Status Active Business Owner Information Name Role Effective Date Expiration Date HAGGARD, RYAN L Partner /Member 03/01/2004 9/25/2009 HAGGARD, ELIZABETH A Partner /Member 03/01/2004 $250.00 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 3 PLATTE RIVER INS CO CLB2711966 01/20/2010 Until Cancelled $4,000.00 01/25/2010 2 WESTERN SURETY CO 69839977 01/23/2005 Until Cancelled 01/22/2010 $4,000.00 02/10/2005 Assignment of Savings Information No records found for the previous 6 year period Insurance Information No records found for the previous 6 year period Summons /Complaint Information Summons and Complaints are not filed with the department for this contractor type Warrant Information Warrants are not filed with the department for this contractor type Infractions /Citations Information Infraction / Citation Date RCW Code Type Status Violation Amount EMEHU02999 9/25/2009 19.28.161(6) RCW ELECTRICAL CITATION Satisfied $250.00 EMEHU02998 9/25/2009 19.28.271 RCW ELECTRICAL CITATION Not satisfied $500.00 EMABQ02512 11/4/2008 19.28.101 RCW ELECTRICAL CITATION Satisfied $1,000.00 EBLAG00280 12/18/2008 19.28.101 RCW ELECTRICAL CITATION Satisfied $1,000.00 EBLAG00279 12/18/2008 19.28.161 RCW ELECTRICAL CITATION Satisfied $250.00 EMOMJ00340 3/30/2010 19.28.101 RCW ELECTRICAL CITATION Not satisfied $500.00 EJORP01777 10/2/2007 19.28.101 RCW ELECTRICAL CITATION Satisfied $250.00 EHULR00241 1/12/2010 19.28.101 RCW ELECTRICAL CITATION Satisfied $250.00 ESTRL00821 3/19/2009 19.28.271 RCW ELECTRICAL CITATION Satisfied $250.00 EHULR00248 3/11/2010 19.28.101 RCW ELECTRICAL CITATION Not satisfied $500.00 https: // fortress .wa.gov /lni /bbip/Print.aspx 11/02/2011 1 FLOOR PLAN - LIGHTING El .1 SCALE 1/4" = 1' -0" GENERAL NOTES: A. MINIMUM WIRE /CONDUIT SIZE SHALL BE 2 #12,1 #12G. IN 1/2" CONDUIT. B. PROVIDE GROUNDING CONDUCTOR IN CIRCUITS SHOWN AND AS REQUIRED BY LOCAL CODES AND AUTHORITY HAVING JURISDICTION. C. WIRING DEVICES SHALL BE DECORA STYLE, WHITE NYLON WITH WHITE NYLON COVER PLATES. D. ALL CONDUITS SHALL BE CONCEALED EXCEPT IN THE ELECTRICAL AREA. E. ALL EXPOSED CONDUIT, STRAPS AND APPURTENANCES SHALL BE PAINTED TO MATCH ADJACENT SURFACE. REFERENCE ARCHITECTURAL PAINTING SPECIFICATIONS. F. FIRE STOP ALL PENETRATIONS THROUGH FIRE RATED PARTITIONS WITH AN APPROVED ASSEMBLY EQUAL TO OR GREATER THAN THE RATING OF THE PARTITION BEING PENETRATED. G. REMOVE ALL UNUSED CONDUIT /WIRING, OUTLET BOXES AND APPURTENANCES. THE FIRE ALARM CONTRACTOR MUST BE APPROVED BY "SOUTHCENTER" AND IS RESPONSIBLE FOR DESIGN, DESIGN APPROVAL, INSTALLATION AND FINAL ACCEPTANCE BY THE AUTHORITIES HAVING JURISDICTION. DEVICES AND EQUIPMENT SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. FINAL DEVICE TYPES, QUANTITIES AND LOCATIONS ARE THE RESPONSIBILITY OF THE CONTRACTOR. COORDINATE EXACT LOCATION OF DEVICES WITH ARCHITECT PRIOR TO ROUGH —IN. FAILURE TO COMPLY WITH THESE REQUIREMENTS WILL NOT RESULT IN ADDITIONAL COST TO THE TENANT AND /OR OWNER. i KEYED NOTES BY SYMBOL ' U': 1. SHOW WINDOW RECEPTACLE PER NEC 210.62. MOUNT RECEPTACLE FLUSH IN CEILING. 2. ROUTE ONE 3/4" CONDUIT WITH PULL CORD UP WALL TO ABOVE CEILING. CONTINUE CONDUIT AND PULL CORD ABOVE CEILING TO THE TELEPHONE SERVICE PUNCH DOWN. INSTALL A 90' LONG RADIUS BEND AND INSULATED BUSHING ON END OF CONDUIT. 3. ROUTE ONE 3/4" CONDUIT WITH PULL CORD INSIDE MILLWORK TO DEVICES SHOWN. COORDINATE ROUTING OF CONDUIT AND FINAL LOCATION OF DEVICE IN MILLWORK WITH ARCHITECT PRIOR TO ROUGH —IN. 4. ROUTE CIRCUIT SHOWN INSIDE MILLWORK TO DEVICES SHOWN. COORDINATE ROUTING OF CONDUIT AND FINAL 'LOCATION OF DEVICE IN MILLWORK WITH ARCHITECT PRIOR TO ROUGH —IN. 5. EXISTING 120/208 VOLT, THREE PHASE PANELBOARD TO REMAIN. REFERENCE ELECTRICAL RISER DIAGRAM, SHEET E2.0 FOR ADDITIONAL WORK REQUIRED. 6. PROVIDE OUTLET BOX AND 3/4" CONDUIT TO ABOVE CEILING. CONTINUE ROUTING ABOVE CEILING TO STORAGE ROOM AND INSTALL INSULATED BUSHING ON END OF CONDUIT. USE ONLY LONG RADIUS BENDS. 7. RECEPTACLE MOUNTED FLUSH AT CEILING FOR POWER TO LIGHT BOX. 8. LIGHTING CONTACTOR LC1, TIME CLOCKS 'TC1' AND TC2 ABOVE. REFERENCE SHEET E2.0 FOR ADDITIONAL WORK REQUIRED. EWH -1 (ABOVE CEILING) LA- 15,17,19 THRU VFD 3 #12,1 #12G.,3 /4" C. I FLOOR PLAN - POWER E1.� SCALE 1/4" = 1 -0 KEYED NOTES BY SYMBOL CONTINUED ' O': 9. SWITCH SHOWN SHALL CONTROL LIGHTING CONTACTOR LC1. REFERENCE SHEET E2.0 FOR ADDITIONAL WORK REQUIRED. 10. CEILING MOUNTED FIRE ALARM SPEAKER STROBE. COORDINATE INSTALLATION AND PERFORMANCE REQUIREMENTS WITH MALL MANAGER PRIOR TO ROUGH —IN. 11. POWER FOR OUTSIDE AIR MOTORIZED DAMPER MOTOR. COORDINATE LOCATION AND CONNECTION REQUIREMENTS WITH MECHANICAL CONTRACTOR PRIOR TO ROUGH —IN. ELECTRICAL CONTRACTOR SHALL MAKE ALL LINE VOLTAGE CONNECTIONS. MECHANICAL CONTRACTOR SHALL MAKE ALL LOW VOLTAGE CONNECTIONS. 12. VARIBLE FREQUENCY DRIVE (VFD) PROVIDED BY THE MECHANICAL CONTRACTOR. 13. PROVIDE A 24" WIDE X 48" HIGH X 3/4" THICK, AC GRADE PLYWOOD BACKBOARD FOR TELEPHONE SERVICE. PAINT PLYWOOD TO MATCH ADJACENT WALL SURFACE. COORDINATE MOUNTING WITH ARCHITECT PRIOR TO ROUGH —IN. PROVIDE ONE 2" CONDUIT WITH PULL CORD FROM THE BACKBOARD TO THE LANDLORD POINT OF DEMARCATION FOR TELEPHONE SERVICE. USE ONE LONG RADIUS BEND AND INSTALL INSULATED BUSHING ON ENDS OF CONDUIT. ARJO ENGINEERS, INC. Consulting Engineers 4140 LEMMON AVE. SUITE 275, LB 110 DALLAS, TEXAS 75219 -3763 PH. (214) 520 -7799 FAX. (214) 520 -7897 'SEPARATE E PERMIT REQUIRED FOR: D Electrical &Plumbing p-as piping City of Tukwila BL il_DING DIVISION FILE COPY Permit 839 Ple• rrvlevapproval is sit to effOIS and ornIssions. of construction documents does not authorize 1.. ..: of any adopted code or ordinance. Receipt a: Loprovei Field Copy and conc ionsisadmowledjed gym Daw , //-2 2 /2' City Of'Nkwila BUILDING DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. t`` 17: v ;sions will require a new plan submittal civil may include additional plan review fees. REVIEWED FOR COMPLIANCE WITH NFPA70 - NEC SEP 2 0 2011 UK— City of Tukwila BUILDING DIVISION CITY�FT�3Rr'"'r' SEP 07 2011 PERMIT CENTER DATE: 08.03.11 JOB NO: 1111 (5147) DRAWN: CM CHECKED: CM 711 N. FIELDER RD. ARLINGTON, TX 76012 PH: (817) 635 -5696 FAX: (817) 635 -5699 0 • — E 0 U SOUTHCENTER WA 98188 REVISIONS Q 05.27.11 REVISIONS AFTER LANDLORD COMMENTS 1,k1 -0 38 FLOOR PLAN - POWEF LIGHTING AND SHEET NUMBER E1.0 ELECTRICAL SPECIFICATIONS: GENERAL CONDITIONS THE GENERAL CONDITIONS, SPECIAL CONDITIONS, SUPPLEMENTARY CONDITIONS AND ELECTRICAL SPECIFICATIONS CONTAINED IN THE AIA "GENERAL CONDITIONS OF THE CONTRACT", CURRENT EDITION, SHALL APPLY TO ALL WORK ON THIS PROJECT EXCEPT AS MODIFIED HEREIN. THE CONTRACTOR SHALL ALSO REFER TO THE ARCHITECTURAL, STRUCTURAL, AND MECHANICAL PLANS AND SPECIFICATIONS, WHICH ARE CONTRACT DOCUMENTS. BIDDERS SHALL VISIT THE SITE AND FAMILIARIZE THEMSELVES WITH ALL CONDITIONS SURROUNDING THE WORK PRIOR TO SUBMITTING THEIR BID. REQUIREMENTS ALL WORK SHALL MEET THE CURRENT NATIONAL ELECTRICAL CODE, APPLICABLE LOCAL ELECTRICAL CODE, AND ALL OTHER APPLICABLE CODES, ALL UTILITY REQUIREMENTS, AND ALL OWNER REQUIREMENTS AS TO CONSTRUCTION AND INSURANCE. THE CONTRACTOR SHALL PROCURE AND PAY FOR ALL REQUIRED PERMITS AND UTILITY SERVICE CHARGES. GUARANTEE THE CONTRACTOR SHALL UNCONDITIONALLY GUARANTEE ALL WORK UNDER THIS CONTRACT TO BE FREE FROM DEFECTS IN WORKMANSHIP AND MATERIALS FOR A PERIOD OF ONE YEAR FROM THE DATE OF FINAL ACCEPTANCE OF THE WORK BY THE OWNER. CONTRACTOR SHALL MAKE GOOD ALL SUCH FAULTY ITEMS IDENTIFIED TO HIM DURING THIS PERIOD WITHOUT COST TO OWNER: PLANS AND SPECIFICATIONS IT IS THE INTENT OF THE PLANS AND SPECIFICATIONS TO PROVIDE FOR A COMPLETE INSTALLATION. EVERYTHING NECESSARY FOR THE COMPLETION AND SUCCESSFUL OPERATION OF THE WORK, WHETHER OR NOT HEREIN DEFINITELY SPECIFIED OR INDICATED SHALL BE FURNISHED AND INSTALLED AS IF SO SPECIFIED OR INDICATED WITHOUT ADDITIONAL COST TO OWNER. THE DRAWINGS ARE DIAGRAMMATIC AND NOT INTENDED TO SHOW EXACT LOCATIONS UNLESS DIMENSIONED. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND LENGTHS, AND SHALL ADJUST HIS EQUIPMENT AND RACEWAY LOCATIONS TO AVOID CONFLICTS WITH OTHER CONSTRUCTION OR EQUIPMENT. IF ANY ERRORS, DISCREPANCIES OR OMISSIONS APPEAR IN THE PLANS, SPECIFICATIONS OR OTHER CONTRACT DOCUMENTS, THE CONTRACTOR SHALL NOTIFY THE ARCHITECT, OR, FAILING TO DO SO BEFORE CONSTRUCTION AND /OR FABRICATION OF THE WORK, SHALL BE HELD RESPONSIBLE FOR THE RESULTS OF ANY SUCH ERRORS, DISCREPANCIES OR OMISSIONS AND THE COST OF RECTIFYING SAME. NOTWITHSTANDING ANY OTHER PROVISIONS OF THE CONTRACT DOCUMENTS, THE CONTRACTOR BEARS ULTIMATE RESPONSIBILITY FOR THE COMPLIANCE OF THE INSTALLATION WITH THE REQUIREMENTS OF THE OWNER AND OF THE LOCAL AUTHORITY HAVING JURISDICTION. MANUFACTURER'S NAMES ARE LISTED HEREIN AND ON THE DRAWINGS TO ESTABLISH A STANDARD FOR QUALITY AND DESIGN. WHERE ONE MANUFACTURER'S NAME IS MENTIONED, PRODUCTS OF OTHER MANUFACTURERS WILL BE ACCEPTABLE IF, IN THE OPINION OF THE ARCHITECT, THE SUBSTITUTE MATERIAL IS OF QUALITY EQUAL TO OR BETTER THAN THAT OF THE MATERIAL SPECIFIED. WHERE TWO OR MORE MANUFACTURER'S NAMES ARE SPECIFIED, MATERIAL SHALL BE BY ONE OF THE NAMED MANUFACTURERS ONLY. MODIFICATIONS MINOR ADJUSTMENTS TO THE PLANS AND SPECIFICATIONS, INCLUDING EQUIPMENT VOLTAGE REQUIREMENTS AND OUTLET LOCATIONS, MAY BE REQUESTED BY THE OWNER DURING THE PROJECT. CONTRACTOR SHALL MAKE SUCH ADJUSTMENTS WITHOUT ADDITIONAL COST TO THE OWNER WHERE SUCH ADJUSTMENTS ARE NECESSARY TO THE PROPER INSTALLATION AND OPERATION AND WITHIN THE INTENT OF THE CONTRACT DOCUMENTS. SUBMITTALS AFTER THE CONTRACT IS AWARDED, BUT PRIOR TO PROCEEDING WITH THE WORK, THE CONTRACTOR SHALL OBTAIN COMPLETE SHOP DRAWINGS, PRODUCT DATA AND SAMPLES FROM THE MANUFACTURERS, SUPPLIERS, VENDORS, AND SUBCONTRACTORS, FOR ALL MATERIALS AND EQUIPMENT SPECIFIED HEREIN, AND SUBMIT DATA AND DETAILS OF SUCH MATERIALS AND EQUIPMENT FOR REVIEW BY THE ARCHITECT AND ENGINEER. PRIOR TO SUBMISSION OF THE SHOP DRAWINGS, PRODUCT DATA AND SAMPLES TO THE ARCHITECT AND ENGINEERS, THE CONTRACTOR SHALL REVIEW AND CERTIFY THAT THE SHOP DRAWINGS, PRODUCT DATA AND SAMPLES ARE IN COMPLIANCE WITH THE CONTRACT DOCUMENTS. A MINIMUM PERIOD OF TEN WORKING DAYS, EXCLUSIVE OF TRANSMITTAL TIME, WILL BE REQUIRED IN THE ENGINEER'S OFFICE EACH TIME SHOP DRAWINGS, PRODUCT DATA AND /OR SAMPLES ARE SUBMITTED OR RESUBMITTED FOR REVIEW. THIS TIME PERIOD SHALL BE CONSIDERED BY THE CONTRACTOR WHEN SCHEDULING HIS WORK. THE CONTRACTOR SHALL PROVIDE THE ENGINEER WITH A MINIMUM OF FIVE CERTIFIED COPIES OF ALL SHOP AND EQUIPMENT DRAWINGS FOR HIS APPROVAL, TWO OF WHICH SHALL BE RETAINED BY THE ENGINEER, THE REMAINING COPIES WILL BE RETURNED TO THE CONTRACTOR. INSTALLATION, ALL ELECTRICAL WORK SHOWN AND REQUIRED SHALL BE BY THE CONTRACTOR, UNLESS OTHERWISE STATED, WHO SHALL FURNISH AND INSTALL MINOR ITEMS REASONABLY NECESSARY FOR THE COMPLETION OF THE WORK, AND MAKE FINAL CONNECTIONS. ALL CUTTING AND PATCHING OF EXISTING CONDITIONS REQUIRED FOR THE WORK OF THIS CONTRACT SHALL BE BY THE CONTRACTOR. ALL TEMPORARY WIRING SHALL BE FURNISHED, INSTALLED AND REMOVED BY THE CONTRACTOR. THE CONTRACTOR SHALL KEEP A SET OF DRAWINGS ON THE JOB, NOTING DAILY ALL CHANGES MADE IN THESE DRAWINGS AND IN CONNECTION WITH THE FINAL INSTALLATION, INCLUDING EXACT DIMENSIONED LOCATIONS OF ALL NEW AND UNCOVERED EXISTING UTILITY PIPING OUTSIDE THE BUILDING. PRIOR TO COMPLETION OF THE PROJECT, THE CONTRACTOR SHALL TRANSFER THE COMPLETE INFORMATION TO "CAD" DRAWINGS, AND SHALL, WITH HIS REQUEST FOR FINAL PAYMENT, TURN OVER A CLEAN, NEATLY PREPARED SET OF "CAD" REPRODUCIBLE DRAWINGS SHOWING "AS INSTALLED" WORK TO THE ARCHITECT FOR REVIEW AND SUBSEQUENT TRANSMITTAL TO THE OWNER. UPON ACCEPTANCE OF THE "CAD" DRAWINGS BY THE OWNER, THE CONTRACTOR SHALL PROVIDE THE ARCHITECT WITH ONE SET OF THE DRAWINGS ON A "CAD" CD AND ONE SET OF REPRODUCIBLE DRAWING PLOTS. "CAD" DRAWINGS SHALL BE IN AUTOCAD 2009 FORMAT. LIGHTING FIXTURES FLUORESCENT FIXTURES SHALL BE CONNECTED BY MEANS OF FLEXIBLE CONDUIT AND 150 DEGREE CENTIGRADE WIRE RUN TO A BRANCH CIRCUIT OUTLET BOX INDEPENDENT OF THE FIXTURE. CONDUIT AND WIRE ALL WIRING SHALL BE INSTALLED IN STEEL CONDUIT UNLESS OTHERWISE INDICATED OR SPECIFIED. CONDUIT SHALL BE EMT, EXCEPT SHORT FINAL CONNECTIONS TO MECHANICAL EQUIPMENT, LIGHTING FIXTURES, AND TRANSFORMERS SHALL BE FMC (OR LTFMC IF IN A WET LOCATION). CONDUIT SHALL BE CONCEALED IN ALL FINISHED AREAS OF THE SPACE. FITTINGS SHALL BE SETSCREW OR COMPRESSION TYPE AS APPROPRIATE. CONDUIT SHALL NOT BE RUN THROUGH OR ATTACHED TO HVAC DUCTS. ALL INTERIOR WIRE SHALL BE COPPER, TYPE THHN, OR AS NOTED, NO. 12 AWG MINIMUM, OR AS SHOWN. ALL EXTERIOR WIRE SHALL BE COPPER, TYPE XHHW, OR AS NOTED, NO. 12 AWG MINIMUM, OR AS SHOWN. ALL FLOOR PENETRATIONS SHALL USE FIRE RATED DEVICES AND SHALL MAINTAIN THE RATING OF THE FLOOR. ALL COMBINED CIRCUITS IN COMMON RACEWAY SHALL COMPLY WITH NEC FOR DISCONNECTING MEANS FOR MULTIWIRE BRANCH CIRCUITS. ELECTRICAL EQUIPMENT ALL EQUIPMENT SHALL BE NEW, UL LISTED, COMMERCIAL GRADE, AND WEATHERPROOF IF EXPOSED TO WEATHER. DISCONNECT SWITCHES SHALL BE NEMA RATED, HEAVY DUTY, 3P, N -F UNLESS SHOWN WITH FUSES. BRANCH CIRCUIT BREAKERS SHALL BE BOLT —ON, 10,000 AIC FOR 120/208 VOLT, CENTER TRIP. SINGLE POLE BREAKERS SHALL BE SWD RATED. MULTIPOLE BREAKERS SHALL BE COMMON TRIP. THE PANEL DOOR SHALL CONTAIN A TYPEWRITTEN BRANCH CIRCUIT DIRECTORY. TRANSFORMERS SHALL BE DRY —TYPE "TP1 ", 115 DEGREE C RISE, KVA RATING AS INDICATED ON PLANS. LABEL ALL EQUIPMENT AS REQUIRED BY 2011 NEC 110.24. WIRING DEVICES UNLESS OTHERWISE INDICATED ON PLANS: WIRING DEVICES SHALL BE SPECIFICATION GRADE, WHITE COLOR, SIDE WIRED, 20 AMP HUBBELL: 1221 SERIES SWITCHES, 5362 SERIES RECEPTACLE OR EQUAL PRODUCT OF P &S OR LEVITON. PLATES SHALL BE SMOOTH WHITE NYLON. WALL OUTLET BOXES SHALL BE KNOCKOUT TYPE, EXCEPT CAST WATERPROOF TYPE SHALL BE USED IN WET LOCATIONS. FLOOR BOXES SHALL BE CAST IRON, FULLY ADJUSTABLE, WITH BRASS COVER PLATE, BRASS CARPET FLANGE AND FLUSH FITTINGS, HUBBELL, THOMAS & BETTS, OR EQUAL. INSTALL SWITCHES AT 48" A.F.F. AND RECEPTACLES AT 18" A.F.F. UNLESS NOTED OTHERWISE. MECHANICAL EQUIPMENT THE PLANS ARE BASED UPON SERVICE REQUIREMENTS OF THE MECHANICAL EQUIPMENT SPECIFIED. THIS CONTRACTOR SHALL BE REIMBURSED BY THE MECHANICAL CONTRACTOR, NOT BY THE OWNER, FOR ANY COSTS INCURRED DUE TO MECHANICAL CONTRACTOR'S SUBSTITUTION OF EQUIPMENT HAVING DIFFERENT ELECTRICAL CHARACTERISTICS. COORDINATION: IT IS THE CONTRACTOR'S RESPONSIBILITY TO REVIEW THE DRAWINGS PERTAINING TO THE ARCHITECTURAL, MECHANICAL, AND PLUMBING DISCIPLINES. GROUND LEVEL ARJO ENGINEERS, INC. FLI Consulting Engineers 4140 LEMMON AVE. SUITE 275, LB 110 DALLAS, TEXAS 75219 -3763 PH. (214) 520 -7799 FAX. (214) 520 -7897 rl_l.. :X. 'LM 120/208 L!J ® 10 4 O ELECTRICAL RISER DIAGRAM scale = none LA -14 KEYED NOTES BY SYMBOL "O ": 1. EXISTING ELECTRIC SERVICE METER TO REMAIN. 2. EXISTING FEEDER AND CONDUIT TO REMAIN. 3. EXISTING 120/208 VOLT, 3 POLE, 200 AMP DISCONNECT TO REMAIN. 4. EXISTING ELECTRIC SERVICE GROUND TO REMAIN. 5. EXISTING 120/208 VOLT, 3 PHASE, 4 WIRE PANELBOARD WITH 200 AMP MAIN CIRCUIT BREAKER TO REMAIN. 6. LIGHTING CIRCUITS ROUTED THROUGH LIGHTING CONTACTOR LC1. REFERENCE WIRING DIAGRAM THIS SHEET FOR ADDITIONAL WORK REQUIRED. 7. LIGHTING CONTACTOR LC1. REFERENCE WIRING DIAGRAM THIS SHEET FOR ADDITIONAL WORK REQUIRED. 8. TIME CLOCK TC -1. TORK MODEL 7200Z OR ACCEPTABLE ALTERNATE. 9. LIGHT BOX CIRCUIT ROUTED THROUGH TIME CLOCK TC -2. 10. TIME CLOCK TC -2. TORK MODEL 7200Z OR ACCEPTABLE ALTERNATE. z J 0 z zzz 6 ca tea J -J LI J w tic 57 ;I 5141 iictw Cluj 6 POLE, ELECTRICALLY OPERATED LIGHTING CONTACTOR IN NEMA 1 ENCLOSURE LIGHTING CONTACTOR 'LC1' scale = none ___.______.�... 85 REVIEWED FOR COMPLIANCE WITH NFPA70 -NEC SEP 202011 City of Tukwila. BUILDING DIVISION crnSFAu SEP 0 7 2011 PERMIT CENTER DATE: 08.03.11 JOB NO: 1111 (5147) DRAWN: cm CHECKED: cm 711 N. FIELDER RD. ARLINGTON, TX 76012 PH: (817) 635 -5696 FAX: (817) 635 -5699 N 0 U O N w U 0 633 SOUTHCENTER REVISIONS 00 co 00 SEATTLE, WA A 05.27.11 REVISIONS AFTER LANDLORD COMMENTS ELECTRICAL SCHEDULES, DETAILS & SPECIFICATIONS SHEET NUMBER E2.0 LIGHT FIXTURE SCHEDULE LOAD TYPE DESCRIPTION VOLTAGE LAMPS REMARKS SERVES A LIGHTOLIER 70/302MRX- 70 /379WHX —W/ 50 WATT MAX LABEL LOW VOLTAGE CEILING MOUNTED ELBOW W/ 1 LAMP, MAGNETIC BALLAST, & WHITE FINISH 120 (1)Q50MR16/ CG25 DOWN LTS & PENDANTS 20/1 B1 LITELINE (4)J —UNI- 1190— WH/TK6004 —WH (4) LINE VOLTAGE TRACK HEADS W/ YOKE MOUNTING, ADJUSTABLE PORCELAIN SOCKET & WHITE FINISH / 4' SINGLE CIRCUIT TRACK & WHITE FINISH 120 (4)FLE13/ PAR20/827 PROVIDE ALL REQUIRED MOUNTING APERTENANCES RECEPTACLES B2 LITELINE (5)J— UNI - 1190— WH/TK6006 —WH (5) LINE VOLTAGE TRACK HEADS W/ YOKE MOUNTING, ADJUSTABLE PORCELAIN SOCKET & WHITE FINISH / 6' SINGLE CIRCUIT TRACK & WHITE FINISH 120 (5)FLE13/ PAR20/827 PROVIDE ALL REQUIRED MOUNTING APERTENANCES TRACK LIGHTING B3 LITELINE (8)J— UNI - 1190— WH/TK6008 —WH (8) LINE VOLTAGE TRACK HEADS W/ YOKE MOUNTING, ADJUSTABLE PORCELAIN SOCKET & WHITE FINISH / 8' SINGLE CIRCUIT TRACK & WHITE FINISH 120 (8)FLE13/ PAR20/827 PROVIDE ALL REQUIRED MOUNTING APERTENANCES B4 LITELINE (12)J— UNI - 1190— WH /(2)TK6008 —WH (12) LINE VOLTAGE TRACK HEADS W/ YOKE MOUNTING, ADJUSTABLE PORCELAIN SOCKET & WHITE FINISH / (2) 8' SINGLE CIRCUIT TRACKS & WHITE FINISH 120 (12)FLE13/ PAR20/827 PROVIDE ALL REQUIRED MOUNTING APERTENANCES 85 LITELINE (14)J— UNI - 1190— WH /(2)TK6008 —WH (14) LINE VOLTAGE TRACK HEADS W/ YOKE MOUNTING, ADJUSTABLE PORCELAIN SOCKET & WHITE FINISH / (2) 8' SINGLE CIRCUIT TRACKS & WHITE FINISH 120 (14)FLE13/ PAR20 /827 PROVIDE ALL REQUIRED MOUNTING APERTENANCES 20/1 C TMS LIGHTING GAS18AL— F05— DMICF32— CFDCB120 —F05 FLUORESCENT HIGH BAY W/ 1 LAMP, ELECTRONIC BALLAST, WHITE REFLECTOR & WHITE DROP CORD MOUNTING, 120/277 (1)F32TBX/ 835 /A /ECO COORDINATE FINAL MOUNTING HEIGHT W/ ARCHITECT PRIOR TO ROUGH —IN 20/1 D LIGHTOLIER SW4S232HPF -120S0 4' FLUORESCENT STRIP W/ 2 LAMPS, ELECTRONIC BALLAST, SYMEMETRICAL REFLECTOR, WIRE GUARD & WHITE FINISH 120 (2)F32T8/ 835/ECO E CONCEALITE F5- 12 -90 —WH RECESSED LOW VOLTAGE EMERGENCY EGRESS LIGHT W/ MOTORIZED DOOR, 2 LAMPS, & WHITE FINISH 120/277 INCLUDED FIXTURE IS UNSWITCHED 400 X1 LIGHTOLIER EX- 1R- 3— RC— C —N —WH LED SINGLE FACE EXIT SIGN W/ RED LETTERS, CLEAR PANEL, RECESSED CEILING MOUNTED, EMERGENCY BATTERY PACK & WHITE FINISH 120/277 INCLUDED FIXTURE IS UNSWITCHED UC REFRIGERATOR GROUND LEVEL ARJO ENGINEERS, INC. FLI Consulting Engineers 4140 LEMMON AVE. SUITE 275, LB 110 DALLAS, TEXAS 75219 -3763 PH. (214) 520 -7799 FAX. (214) 520 -7897 rl_l.. :X. 'LM 120/208 L!J ® 10 4 O ELECTRICAL RISER DIAGRAM scale = none LA -14 KEYED NOTES BY SYMBOL "O ": 1. EXISTING ELECTRIC SERVICE METER TO REMAIN. 2. EXISTING FEEDER AND CONDUIT TO REMAIN. 3. EXISTING 120/208 VOLT, 3 POLE, 200 AMP DISCONNECT TO REMAIN. 4. EXISTING ELECTRIC SERVICE GROUND TO REMAIN. 5. EXISTING 120/208 VOLT, 3 PHASE, 4 WIRE PANELBOARD WITH 200 AMP MAIN CIRCUIT BREAKER TO REMAIN. 6. LIGHTING CIRCUITS ROUTED THROUGH LIGHTING CONTACTOR LC1. REFERENCE WIRING DIAGRAM THIS SHEET FOR ADDITIONAL WORK REQUIRED. 7. LIGHTING CONTACTOR LC1. REFERENCE WIRING DIAGRAM THIS SHEET FOR ADDITIONAL WORK REQUIRED. 8. TIME CLOCK TC -1. TORK MODEL 7200Z OR ACCEPTABLE ALTERNATE. 9. LIGHT BOX CIRCUIT ROUTED THROUGH TIME CLOCK TC -2. 10. TIME CLOCK TC -2. TORK MODEL 7200Z OR ACCEPTABLE ALTERNATE. z J 0 z zzz 6 ca tea J -J LI J w tic 57 ;I 5141 iictw Cluj 6 POLE, ELECTRICALLY OPERATED LIGHTING CONTACTOR IN NEMA 1 ENCLOSURE LIGHTING CONTACTOR 'LC1' scale = none ___.______.�... 85 REVIEWED FOR COMPLIANCE WITH NFPA70 -NEC SEP 202011 City of Tukwila. BUILDING DIVISION crnSFAu SEP 0 7 2011 PERMIT CENTER DATE: 08.03.11 JOB NO: 1111 (5147) DRAWN: cm CHECKED: cm 711 N. FIELDER RD. ARLINGTON, TX 76012 PH: (817) 635 -5696 FAX: (817) 635 -5699 N 0 U O N w U 0 633 SOUTHCENTER REVISIONS 00 co 00 SEATTLE, WA A 05.27.11 REVISIONS AFTER LANDLORD COMMENTS ELECTRICAL SCHEDULES, DETAILS & SPECIFICATIONS SHEET NUMBER E2.0 EXISTING PANEL 'LA' 10,000 AMPS RMS SYM I.C. INTEGRATED EQUIPMENT RATING 208Y /120VOLTS, 3 PHASE, 4 WIRE 200 AMPS MAIN CIRCUIT BREAKER LOAD ZONE SERVES TRIP PHASE "A" PHASE "B" PHASE "C" TRIP SERVES ZONE LOAD L LC1 DOWN LTS & PENDANTS 20/1 oi• 210 720 ' 20/1 RECEPTACLES R •02 L LC1 TRACK LIGHTING 20/1 510 360 20/1 RECEPTACLES R 03 • •— • • • o4 L LC1 TRACK LIGHTING 20/1 270 720 •0s 20/1 POS RECEPTACLES R 0.5 L LC1 DOWN LIGHTS 20/1 07• 400 1 1000 • 20/1 UC REFRIGERATOR X •08 A A A RTU -1 45/3 2880 500 20/1 LIGHT BOX TC2 L 09 • • • • io 2880 1 •12 20/1 SPARE 11' • 13 • 2880 500 20/1 LIGHTING CONTROLS X '14 M M M EF -1 20/3 552 3000 40/2 EWH -1 X X 15_ • • • • i6 552 1 3000 •18. 17 • 19• 552 1 360 20/1 TELEPHONE RECEPT R • •20 SPACE 1 SPACE 21' • • •22 SPACE 1 •24 SPACE 23 • SPACE 25 • 1 SPACE •26 SPACE 27 ' SPACE • 28 SPACE • 30 SPACE 29' • SPACE 31 1 32 34 SPACE SPACE 33 35 SPACE SPACE 36 SPACE SPACE 37 1 38 40 SPACE SPACE 39 1 SPACE SPACE 41 1 42 SPACE LOAD DESCRIPTION 6622 1 7802 7422 L = LIGHTING R = RECEPT. X = MISC. TOTAL CONN. LOAD 21.8 KVA M = MOTOR LM = LARGEST MOTOR TOTAL DEMAND LOAD 22.3 KVA A = A/C H = HEAT RA = RANGE K = KITCHEN D = DRYER GROUND LEVEL ARJO ENGINEERS, INC. FLI Consulting Engineers 4140 LEMMON AVE. SUITE 275, LB 110 DALLAS, TEXAS 75219 -3763 PH. (214) 520 -7799 FAX. (214) 520 -7897 rl_l.. :X. 'LM 120/208 L!J ® 10 4 O ELECTRICAL RISER DIAGRAM scale = none LA -14 KEYED NOTES BY SYMBOL "O ": 1. EXISTING ELECTRIC SERVICE METER TO REMAIN. 2. EXISTING FEEDER AND CONDUIT TO REMAIN. 3. EXISTING 120/208 VOLT, 3 POLE, 200 AMP DISCONNECT TO REMAIN. 4. EXISTING ELECTRIC SERVICE GROUND TO REMAIN. 5. EXISTING 120/208 VOLT, 3 PHASE, 4 WIRE PANELBOARD WITH 200 AMP MAIN CIRCUIT BREAKER TO REMAIN. 6. LIGHTING CIRCUITS ROUTED THROUGH LIGHTING CONTACTOR LC1. REFERENCE WIRING DIAGRAM THIS SHEET FOR ADDITIONAL WORK REQUIRED. 7. LIGHTING CONTACTOR LC1. REFERENCE WIRING DIAGRAM THIS SHEET FOR ADDITIONAL WORK REQUIRED. 8. TIME CLOCK TC -1. TORK MODEL 7200Z OR ACCEPTABLE ALTERNATE. 9. LIGHT BOX CIRCUIT ROUTED THROUGH TIME CLOCK TC -2. 10. TIME CLOCK TC -2. TORK MODEL 7200Z OR ACCEPTABLE ALTERNATE. z J 0 z zzz 6 ca tea J -J LI J w tic 57 ;I 5141 iictw Cluj 6 POLE, ELECTRICALLY OPERATED LIGHTING CONTACTOR IN NEMA 1 ENCLOSURE LIGHTING CONTACTOR 'LC1' scale = none ___.______.�... 85 REVIEWED FOR COMPLIANCE WITH NFPA70 -NEC SEP 202011 City of Tukwila. BUILDING DIVISION crnSFAu SEP 0 7 2011 PERMIT CENTER DATE: 08.03.11 JOB NO: 1111 (5147) DRAWN: cm CHECKED: cm 711 N. FIELDER RD. ARLINGTON, TX 76012 PH: (817) 635 -5696 FAX: (817) 635 -5699 N 0 U O N w U 0 633 SOUTHCENTER REVISIONS 00 co 00 SEATTLE, WA A 05.27.11 REVISIONS AFTER LANDLORD COMMENTS ELECTRICAL SCHEDULES, DETAILS & SPECIFICATIONS SHEET NUMBER E2.0