Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit EL11-0978 - PAETEC
PAETEC 3311 S 120 PL EL1 1 -0978 Parcel No.: Address: City of/Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov 1023049069 3311 S 120 PL TUKW Project Name: PAETEC ELECTRICAL PERMIT Permit Number: EL11 -0978 Issue Date: 11/15/2011 Permit Expires On: 05/13/2012 Owner: Name: Address: Contact Person: Name: Address: SABEY CORPORATION 12201 TUKWILA INTL BLVD 4THFL , SEATTLE WA JASON PECOTTE 900 N 34 ST, STE 108 , SEATTLE WA Contractor: Name: TITAN ELECTRIC INC Address: 900 N 34 ST, SUITE 108 , SEATTLE WA Contractor License No: TITANEI963OB Phone: 206 633 -2811 Phone: 206 - 633 -2811 Expiration Date: 09/02/2012 DESCRIPTION OF WORK: INSTALL (1) 125 AMP FEED TO (1) 75KV TRANSFORMER, INSTALL (1) 225 AMP PANEL, AND INSTALL (3) 60 AMP CIRCUITS TO COMMERCIAL SPACE. Value of Electrical: NRES: $11,500.00 Fees Collected: RES: $0.00 Type of Fire Protection: UNKNOWN Electrical service provided by: SEATTLE CITY LIGHT Permit Center Authorized Signature: I hereby certify that I have read and e governing this work will be complied The granting of t construction or tl e Signature: permit does not pre perform a of work 'th, National Electrical Code Edition: Date: $373.62 2008 III�S�(I ed this permit and know the same to be true and correct. All provisions of law and ordinances hether specified herein or not. e to give authority to violate or cancel the provisions of any other state or local laws regulating . I am authorized to sign and obtain this electrical permit. Print Name: \s^ PEOT Date: f ^IS=1 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/10 EL11 -0978 Printed: 11 -15 -2011 • PERMIT CONDITIONS Permit No. EL11 -0978 * *ELECTRICAL ** 1: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 2: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 3: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 4: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 5: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 6: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. doc: EL -4/10 EL11 -0978 Printed: 11 -15 -2011 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto://www.TukwilaWA.gov Electrical Permit No. WI 4 ✓ OCki U Project No. Date Application Accepted: Date Application Expires: (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION King Co Assessor's Tax No.: 10219014 — ACV Site Address: 3311 S 120th Place, Tukwila WA 98168 Suite Number: 110 Floor: Main New Tenant: ❑ Yes ®..No Tenant Name: PAETEC PROPERTY OWNER Name: Jason Pecotte Name: PAETEC City: Seattle State: WA Zip: 98103 Address: 3311 South 120th Place # 110 Email: JasonP @TitanFlect jc.Net City: Tukwila State: WA Zip: 98168 CONTACT PERSON — person receiving all project communication Name: Jason Pecotte Address: 900 N 34th St, Suite 108 City: Seattle State: WA Zip: 98103 Phone: (206) 633 -2811 Fax: (206) 374 -2128 Email: JasonP @TitanFlect jc.Net ELECTRICAL CONTRACTOR INFORMATION Company Name: Titan Electric Address: 900 N 34th St, Suite 108 City: Seattle State: WA Zip: 98103 Phone: (206) 622 -2811 Fax: (206) 374 -2128 Contr Reg No.: TitanE19630B Exp Date: 09/02/2012 Tukwila Business License No.: Valuation of Project (contractor's bid price): $ 11,500 Scope of Work (please provide detailed information): Install (1) 125A Feed to (1) 75KV Transformer, Install (1) 225A Panel, Install (3) 60A Circuits.Commercial Will service be altered? ❑ Yes (J No Adding more than 50 amps? © Yes ❑ No Type of Use: Commercial Type of work: ❑ New m Addition ❑ Service Change ❑ Remodel ❑ Tenant Improvement ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service Property Served by: ❑ Puget Sound Energy ® Seattle City Light H :UpplicationeTornwApplicatiors On Line\2011 Applications\Elearical Permit Application Revised 8- 9- 11.docx Revised: August 2011 bh Page 1 of 2 • RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $152.85 (including an attached garage) ❑ Garages, pools, spas and outbuildings $81.90 ea ❑ Low voltage systems (alarm, furnace thermostat) $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $81.90 (no added/altered circuits) ❑ Service change with added/altered circuits $81.90 number of added circuits $11.55 ea ❑ Circuits added/altered without service change $54.60 (up to 5 circuits) ❑ Circuits added/altered without service change $54.60 (6 or more circuits) $7.65 ea ❑ Meter /mast repair $68.25 ❑ Low voltage systems $59.85 (alarm, furnace thermostat) • MULTI - FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $63.00 ❑ Temporary service (generator) $78.75 ❑ Manufactured/mobile home service $84.00 (excluding garage or outbuilding) ❑ Carnivals $78.75 Number of concessions $10.50 ea PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWN " • 1 R ELECTRICAL CONTRACTOR: Signature: Print Name: Jaso ' ecotte Mailing Address: 900 N. 34th St, Suite 108 HAApplicatio s\Forms- Applications On Line \2011 Applications\Electriral Permit Application Revised 8 -9-11. docx Revised' August 2011 bh Date: 10/26/2011 Day Telephone: (206) 511 -7195 Seattle WA 98103 city State Zip Page 2 of 2 CM of Tukwila, • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: //www. ci. tukw ila. wa. us SET RECEIPT RECEIPT NO: R11 -02342 Initials: JEM Payment Date: 10/26/2011 User ID: 1165 Total Payment: 552.12 Payee: TITAN ELECTRIC, INC. SET ID: S000001592 SET NAME: Tmp set/Initialized Activities SET TRANSACTIONS: Set Member EL11 -0977 EL11 -0978 EL11 -0979 TOTAL: Amount 63.00 373.62 115.50 63.00 TRANSACTION LIST: Type Method Description Amount Payment Check 12315 552.12 TOTAL: 552.12 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.0 ELECTRICAL PLAN - NONRES 000.345.832.00.0 477.40 74.72 TOTAL: 552.12 INSPECTION RECORD Retain a copy with permit INSPECTION No. PERMIT NO. CITY: OF' TUKWILA BUILDING DIVISION Y' 6800 Sotithcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 431 -2451 eu,'-o'rr7 Project: � Type of Inspection: Z.../00 Address: zo pit.. Date Called: Special instructions` • Date Wanted:. / / Clyren Requester: Phone No: • Approved per applicable codes. • a•Corrections required prior to approval. COMMENTS: Date: 43/1 3 " REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 63'00 Southcenter Blvd., Suite 100. Call to schedule reinspection. r.' 3. ••• 1:INSPECTION RECORD :Retain a copy with permit INSPECTION NO. P RMIT NO. CITY.OF::TUKWILA BUILDING DIVISION 6300 Southcenter B.ivd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: . p • Type of Inspection: -/00 (�� Address: • • 33-11- ji.a f��- Date Called: Special Instructions:: • Date Wanted:. /2./07 ra.ry m. Requester: Phone No: Approved per applicable codes. E Corrections required prior to approval. COMMENTS: (Inspector: Date: 7/1 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. e e PAETEC FILE COPY Port$ No$ LL I t PI ^- resew approval is subject to errors and omissions. of construction documents does not authorize if, .ion of any adopted code or ordinance. Receipt o'::proveo Fief Copy and is acknowledged: By Date: City Of Ttakwila BUILDING DIVISION SEPARATE PERMIT REQUIRED FOR: Ernechanical 0 Electrical CrPlumbing %was Piping of Tukwila 7.!G DIVISION' SYMBOLS AND ABBREVIATIONS REVIEWED KAI COMPLIANCE' WITH NFPA70 -- NEC NOV 0110 2011 City' of. Tukwila BUILDINGS DIVISION. ELECTRICAL RISER WORK DEFINITION 117- \ RIDER SZE NO41WlCATRN FLAG NOTE ) AVAILABLE FAULT CURRENT NIEN1NWCA1NN © RENSNN I0EN11i1CATIDI' I AUNTS/AK RINSER PATCH IEOUPMENT gENINTCANRI t"a CIROAT BREAKER ECU I PMENT IDENTIFICATION DETAIL REFERENCE GROUND TRANSFORMER' \BIIIIIVAETEC \CM1008VC03 Oct 25. 201 PROJECT NORTH REFERENCE NEW KW ENSTNG FUME REMOTE EXISTING ELECTRICAL EMINENT OUTLET MOUNT1NGIHEIGHTS SPECIAL OUTLET HEIGHTS-ARE SHORN DN NE ELECTRICAL D2AWNCS OR D TI( ARCHITECTURAL DRAWINGS SPECIAL OURET NEWNTS ARE NOT SNOIIN OR REWIRED, NEN 1CCATE OUTLETS AS NOTED BELOW OUTLET NERNTS ARE MEASURED FROM NE FNISHED'FLOON TO NE CENTERLK Cr THE CURET UNLESS ONERNSE NOTED. PNIEIBONOS 172 NOTES (1670 mm) TO TOP Or PAIIIBONiV GENERAL NOTES ti COMPLY NN NE NATIONAL ELECTRICAL COOS AS. ADOPTED' AND MOOED B1' THE LOCAL AUNOBITV NAVNRAJRISDCTNN 2. CCORDNAIE RE LOCARDS Or ELECTRICAL DEVICES N1/1,010ER,PRID2 TO RWD -el REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building DivisionL. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. I ABBREVIATIONS' AMP ATS AOC CB OFT C. CU G.DD J BOOT N.NEUT AMPERE AUTOMATIC TRANSFER SNTD AMERICAN TARE GAUGE CIRCUIT BREMER CIRCUIT CDdJT COPPER GROUND (ROUND FAULT CNQIIT INTERRUPTER ANCTNN BOA NEUTRAL NC Pll RECUT SPECS SNBO TIP IEMR NOT,N CDITRACT emu., PNELBOARD RECEPTACLE SPENICARDS S111TC•3OARD TINCAL VOLT NRE.,MAR, CP AUNINNE TRANSFORMER PHASE RECEIVED, CI 1 I'OFTUKVVI A OCT 2 6 2.0111 PERMIT CENTER tt,kt--(rns TITAN ELECTRIC Full Service El.ctrIcali Technology Controctor von N lay 5.ve IM. Seale. WA 9a101 Mee 2016114811 Far 206-1,2128 p....i 401410melecen[w' SPARLING� RD OOve Way: Slim 1400 Seattle; Wsstangton • 90101.1051. 2166070555 A006620610 mac 9^lwg ca pm t.tl.Tele: PAETEC TKWLWANNI 3311 South 120th, Place Tukwila; WA. SNM rer ELECTRICAL SYMBOLS AND ABBREVIATIONS Designed By Drawn By Prc,c1 No' TMa. Ten Jan. Jon &Wm19 1025eQ0„ SIN.t Num.- E000 e ' 05 (SE.. AP, 1221 20004 4807/2r, ::a ••Al• SINGLE-LINE DIAGRAM 125/3 PROVIDE NEW 115A 3-ROLE BREAKER PI 632010(6.0 90001 E0151340 BREAKER 34C RAMOS 3-1/1.C. 311. I/66 40' 363 0330 73064, 0-13 3405-2100/100 35 45 IL_ NEW PANEL SCHEDULE Spero% p..., Name NEW PANEL -411 120/208V 370 4W 225A Nlam CB Type, Pane !pearl, Locum 5101a2e 141ounled 10 030 AK Serves. %Ike Lugs • Deacnpnon Lead CB I* AIR IC CB l• Lc. Descrevon 0 Spare 003 60/2 CH, X . 0/1 003 Space • 0.03 Space, 5 • Spare 01:0 50/2 03' A10/1 Saxe, 003 Space, 9 Spare 00) 50/1 C8' X EMI 0.03 Space 10 0.03 Space, 12 13. Space 00) 0/1 X 0/1 Space, 14' 15 Space 00)0/1 X 0/1 003 Space. 16 17 Space 00)0/1 00/1 002 Space, 18 19 Space 00)0/1 X 0/1 0.00 Space! 21 Space 0(00/2 ■ X 0/1 003 Space 22 23 Space 0.0)0/1 I X 0/1 003 Space, 24 05 Spn 0(0 0/1 x 0/1 003 Space 27 Space 0.02 0/1 I X 0/1 000 Space 28 29. Space 000 0/1 , X 0/1 003 Space, 30 31 Space 000 0/1 X 0/1 0.00 Spue 32 33 Space 0(0 0/1 x 0/1 000 Space 34 35 Space 00) 0/1 x on ow Saxe 37 Space 00) 0/1 x 0/1 ow Space 39' Space 00)0/1 X 0/1 0.00 Space 401 AI Space 030 0/1 0 o,n 010 Space 42 Rev- Rewsed 073 Marked • Emsing Ckts Marked I 817118 File. IAP17118 \ Paetec \ Sched \ Paetec PK PH A PH 0 71 Gra, Baker Code re G • GEC! 1• 19D Rated 5. 5Iwnt Trip C • KACR Rated D • Sentch•le Dvly a • 554 Note A 4 AFC! Conneced KVA. ' 0(0 00 MOO t , Notes: P307106 21034 NEUTRAL BAR Dem load Type, Conn KVA NEC 0.191)0 Factor 006 De Arm NEC 1.30 34 NEC Feed Amps Space 0(0 ace 0 C 010 _ _ 0 Amps _ 00) 0 qI LOAD)CALtULATIONS' -e PADP12003304804/77791 - EXISTIN)0 = 1259,0 Peak 30day metered load I Added NEC calcul ated I oad from new transform,' S Total Load on UPS 3.3 243 A 12Sli - 304 A 90 A 394 A C. 5-250)er11, (pc 225434� '<11 120/2(00 35. 4* 20.7410.1T . REVIEWED FOR' COMPLIANCE WITH NFPAM- NEC NOV 00 2011 City of Tukwila BUILDING DIVISI'0N1 FLAG1NOTES: [>GOORDiNATE WIN' OWNER FOR NAMING coNveenay RECEIVED' CITY OF TUKIMLA Of7 2 & 2011 PERMIT CENTER TITAN ELECTRIC, F. all Service Electrical I Technology Contractor WON L.. %me Ne. Seale . Phone 315•43,-V111 205-1/4.., I 2111 Paaml Infottutanekoalc.xei SPARLING nORP toGEI,FR IT,. 0,4,7..1 720 olIxe Way.. Sem. 1401 5.406. 0M1503,113171-135" 00 667 0551 01331010(0! nytt•• Prop. Tele PAETEC TICWLWANN 33111South 120th Mice Tukwila; WA Sheet Tele FIFCTRICAL RISERS & PANEL SCHEDULES' 01.19030 90 r.510.3 Drown By Jon &WTI nropct No Oate 10/2542011 Sheet NurriPer. E501 "PERMIT COORD CORY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL11 -0978 DATE: 10/26/11 PROJECT NAME: PAETEC SITE ADDRESS: 3311 S 120 PL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # after Permit Issued Daing EPARTMMEE �S: 1 ,n "Qivision V, Public Works Fire Prevention Structural Planning Division Permit Coordinator ri DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 10/27/11 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: • TUES/THURS ROUTING: Please Route 4] Structural Review Required ri REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: DUE DATE: 11/24/11 Approved Approved with Conditions Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 Contractors or Tradespeople *ter Friendly Page Electrical Contractor A business licensed by LEI to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company TITAN ELECTRIC INC 2066332811 900 N 34Th Ste 108 Seattle WA 98103 King Corporation UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 602250925 Active TITANEI9630B Electrical Contractor 9/2/2004 9/2/2012 General Unused Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status TITANE'986Q5 TITAN ELECTRIC Electrical Contractor General Unused 11/25/2002 11/25/2004 Expired Electrical Administrator INFORMATION License CROOKT *011 PB Name CROOK, TRAVIS Status Active Business Owner Information Name Role Effective Date Expiration Date FUNG, LAWRENCE H Agent 09/02/2004 Bond Amount BURKE, PATRICK D President 09/02/2004 9808431 FUNG, LAWRENCE H Secretary 09/02/2004 ELECTRICAL CITATION CROOK, TRAVIS J Vice President 09/02/2004 COLONIAL AM CAS & SURETY OF MD Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 2 Lexon Ins Co 9808431 08/03/2011 Until Cancelled 19.28.101 RCW ELECTRICAL CITATION $4,000.0008/08/2011 $250.00 1 COLONIAL AM CAS & SURETY OF MD LPM4066933 08/03/2004 Until Cancelled 08/03/2011 $4,000.0008/10/2004 Assignment of Savings Information No records found for the previous 6 year period Insurance Information No records found for the previous 6 year period Summons /Complaint Information Summons and Complaints are not filed with the department for this contractor type Warrant Information Warrants are not filed with the department for this contractor type Infractions /Citations Information Infraction / Citation Date RCW Code Type Status Violation Amount EREEB00416 8/10/2009 19.28.101 RCW ELECTRICAL CITATION Satisfied $1,000.00 EREEB00206 2/20/2009 19.28.101 RCW ELECTRICAL CITATION Satisfied $250.00 ECHAE00321 8/25/2008 19.28.101 RCW ELECTRICAL CITATION Satisfied $250.00 https: // fortress .wa.gov /lni/bbip /Print.aspx 11/15/2011