HomeMy WebLinkAboutPermit EL11-1096 - MUSEUM OF FLIGHTMUSEUM OF FLIGHT
9404 EAST MARGINAL
wys
EL1 1 -1096
City okukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.TukwilaWA.gov
ELECTRICAL PERMIT
Parcel No.: 3324049019
Address: 9404 EAST MARGINAL WY S TUKW
Project Name: MUSEUM OF FLIGHT
Permit Number: EL11 -1096
Issue Date: 12/08/2011
Permit Expires On: 06/05/2012
Owner:
Name: MUSEUM OF FLIGHT FOUNDATION
Address: 9404 EAST MARGINAL WAY S , SEATTLE WA
Contact Person:
Name: ANTHONY STEWART Phone: 202 - 329 -7491
Address: 300E ST SW , WAHINGTON DC
Contractor:
Name:
Address:
Contractor License No:
Phone:
Expiration Date:
DESCRIPTION OF WORK:
INSTALL TEMPORARY GENERARTOR FOR NASA FUTURE FORUM
Value of Electrical:
NRES: $0.00
RES: $0.00
Type of Fire Protection: UNKNOWN
Electrical service provided by: SEATTLE CITY LIGHT
Permit Center Authorized Signature:
Fees Collected:
National Electrical Code Edition:
$78.75
2008
Date: 1)--9—
L'
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied wit hether specified herein or not.
The granting of t
construction or
Signature:
e to give authority to violate or cancel the provisions of any other state or local laws regulating
I am authorized to sign and obtain this electrical permit.
Date:
This permit shall become n and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
doc: EL -4/10
EL11 -1096 Printed: 12 -08 -2011
PERMIT CONDITIONS •
Permit No. EL11 -1096
* *ELECTRICAL **
1: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector
at each work site.
2: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector.
3: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter
296 -46B WAC.
4: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the
building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector.
5: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation
of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that
presumes to grant this authority are therefore not valid.
6: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where
approved plans have been issued, revisions to the plans and additional review may be required.
doc: EL -4/10
E L 11 -1096 Printed: 12 -08 -2011
CITY OF TUKWILd
Community Developm )epartment
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http: / %www.TukwilaWA.gov
ELECTRICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
Site Address: / (/C)L/ t tA..D1” PICA
Tenant Name:
i\AU SQJsf- -
King Co Assessor's Tax No.:
• Sn 41raArl Suite Number: Floor:
Name:
Address:
City:
State:
Zip:
New Tenant: ❑ Yes ❑.. No
Name: A ti
� 1.-3
1L
Address: 300 -...c1:
..t S 1_
�1n1
at I
City: v V a S 11�,
�b -n State:
c
Zips. 4 bi b
Phone: act .)-- 3
°l _ 7 4 `
Email :a .,./ Ot it-
„ ti t nas a , e. ml
New Tenant: ❑ Yes ❑.. No
Valuation of Project (contractor's bid price): $ / 660
Scope of Work (please provide detailed information):
Will service be altered? ❑ Yes ❑ No Adding more than 50 amps? ❑ Yes ❑ No
Type of Use:
Type of work:
❑ New ❑ Addition ❑ Service Change ❑ Remodel ❑ Tenant Improvement
❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service
Property Served by:
❑ Puget Sound Energy ❑ Seattle City Light
H: \Applications\Forms- Applications On Line \2011 Applications\Electrical Permit Application Revised 8-9-11 docx
Revised. August 2011
bh
Page 1 of 2
Company Name: ;t-e_ Q Lk s
Address: �3 6 Li 1,1 a4,` S �' S+
J
City: State:
.Tai0"..,,
Zip:()
"ll
ti S
Phone: Ste`( ir- AL- F a. N
Contr Reg No.: Exp Date:
Tukwila Business License No.;
Valuation of Project (contractor's bid price): $ / 660
Scope of Work (please provide detailed information):
Will service be altered? ❑ Yes ❑ No Adding more than 50 amps? ❑ Yes ❑ No
Type of Use:
Type of work:
❑ New ❑ Addition ❑ Service Change ❑ Remodel ❑ Tenant Improvement
❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service
Property Served by:
❑ Puget Sound Energy ❑ Seattle City Light
H: \Applications\Forms- Applications On Line \2011 Applications\Electrical Permit Application Revised 8-9-11 docx
Revised. August 2011
bh
Page 1 of 2
RESIDENTIAL
NEW RESIDENTIAL SERVICE
❑ New single family dwellings $152.85
(including an attached garage)
❑ Garages, pools, spas and outbuildings $81.90 ea
❑ Low voltage systems
(alarm, furnace thermostat) $59.85 ea
RESIDENTIAL REMODEL AND SERVICE CHANGES
MULTI - FAMILY AND COMMERCIAL
Fees are based on the valuation of the electrical contract.
MISCELLANEOUS FEES
❑ Temporary service (residential) $63.00
Temporary service (generator) $78.75
❑ Manufactured/mobile home service $84.00
❑ Service change or alteration $81.90 (excluding garage or outbuilding)
(no added/altered circuits)
❑ Service change with added/altered circuits $81.90
number of added circuits $11.55 ea
❑ Circuits added/altered without service change $54.60
(up to 5 circuits)
❑ Circuits added/altered without service change $54.60
(6 or more circuits) $7.65 ea
❑ Meter /mast repair $68.25
❑ Low voltage systems $59.85
(alarm, furnace thermostat)
❑ Carnivals $78.75
Number of concessions $10.50 ea
TION4INOTE
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing
and justifiable cause demonstrated.
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWN 1 R ELECTRICAL CONTRACTOR:
fIr
Signature:
Print Name: ),N `^ S■74.A.^.)
Q� d
Mailing Address: 3f b G-. J-I- S l N K4 j . 1k1 J .�� 1 F' 7 U U 0, � w� W t g_o S (cn
City �l State Zip
Date:
Boa— �� -7
Day Telephone: ?q,/
H:1Applications\Forms- Applications On LinA2011 Applications\Elearical Permit Application Revised 8 -9 -1 l.docx
Revised: August 2011
bh
Page 2 of 2
•
C City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.TukwilaWA.gov
RECEIPT
Parcel No.: 3324049019 Permit Number: EL11 -1096
Address: 9404 EAST MARGINAL WY S TUKW Status: PENDING
Suite No: Applied Date: 12/08/2011
Applicant: MUSEUM OF FLIGHT Issue Date:
Receipt No.: R11 -02675
Initials:
User ID:
Payee:
WER
1655
Payment Amount: $78.75
Payment Date: 12/08/2011 03:42 PM
Balance: $0.00
ANTHONY STEWART
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Credit Crd VISA
Authorization No. 83857H
ACCOUNT ITEM LIST:
Description
78.75
Account Code Current Pmts
ELECTRICAL PERMIT - NONR
000.322.101.00.00 78.75
Total: $78.75
doc: Receiot -06 Printed: 12 -08 -2011
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
64- 1076
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION (�
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670
Permit Inspection Request Line (206) 431 -2451
Project: l
V of 644 1
Type of Inspection:
��
Address.
1144
Date Called:
Special Ins ructio
:
Date Wanted:.
/�
P
a.m:
Requester:
1
Phone No:
ALApproved per applicable codes. E Corrections required prior to approval.
COMMENTS:
-/c/- r i:19v
Inspector: Date: /210? /r
ri REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.