Loading...
HomeMy WebLinkAboutPermit EL11-1096 - MUSEUM OF FLIGHTMUSEUM OF FLIGHT 9404 EAST MARGINAL wys EL1 1 -1096 City okukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov ELECTRICAL PERMIT Parcel No.: 3324049019 Address: 9404 EAST MARGINAL WY S TUKW Project Name: MUSEUM OF FLIGHT Permit Number: EL11 -1096 Issue Date: 12/08/2011 Permit Expires On: 06/05/2012 Owner: Name: MUSEUM OF FLIGHT FOUNDATION Address: 9404 EAST MARGINAL WAY S , SEATTLE WA Contact Person: Name: ANTHONY STEWART Phone: 202 - 329 -7491 Address: 300E ST SW , WAHINGTON DC Contractor: Name: Address: Contractor License No: Phone: Expiration Date: DESCRIPTION OF WORK: INSTALL TEMPORARY GENERARTOR FOR NASA FUTURE FORUM Value of Electrical: NRES: $0.00 RES: $0.00 Type of Fire Protection: UNKNOWN Electrical service provided by: SEATTLE CITY LIGHT Permit Center Authorized Signature: Fees Collected: National Electrical Code Edition: $78.75 2008 Date: 1)--9— L' I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied wit hether specified herein or not. The granting of t construction or Signature: e to give authority to violate or cancel the provisions of any other state or local laws regulating I am authorized to sign and obtain this electrical permit. Date: This permit shall become n and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/10 EL11 -1096 Printed: 12 -08 -2011 PERMIT CONDITIONS • Permit No. EL11 -1096 * *ELECTRICAL ** 1: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 2: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 3: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 4: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 5: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 6: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. doc: EL -4/10 E L 11 -1096 Printed: 12 -08 -2011 CITY OF TUKWILd Community Developm )epartment Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http: / %www.TukwilaWA.gov ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** Site Address: / (/C)L/ t tA..D1” PICA Tenant Name: i\AU SQJsf- - King Co Assessor's Tax No.: • Sn 41raArl Suite Number: Floor: Name: Address: City: State: Zip: New Tenant: ❑ Yes ❑.. No Name: A ti � 1.-3 1L Address: 300 -...c1: ..t S 1_ �1n1 at I City: v V a S 11�, �b -n State: c Zips. 4 bi b Phone: act .)-- 3 °l _ 7 4 ` Email :a .,./ Ot it- „ ti t nas a , e. ml New Tenant: ❑ Yes ❑.. No Valuation of Project (contractor's bid price): $ / 660 Scope of Work (please provide detailed information): Will service be altered? ❑ Yes ❑ No Adding more than 50 amps? ❑ Yes ❑ No Type of Use: Type of work: ❑ New ❑ Addition ❑ Service Change ❑ Remodel ❑ Tenant Improvement ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service Property Served by: ❑ Puget Sound Energy ❑ Seattle City Light H: \Applications\Forms- Applications On Line \2011 Applications\Electrical Permit Application Revised 8-9-11 docx Revised. August 2011 bh Page 1 of 2 Company Name: ;t-e_ Q Lk s Address: �3 6 Li 1,1 a4,` S �' S+ J City: State: .Tai0"..,, Zip:() "ll ti S Phone: Ste`( ir- AL- F a. N Contr Reg No.: Exp Date: Tukwila Business License No.; Valuation of Project (contractor's bid price): $ / 660 Scope of Work (please provide detailed information): Will service be altered? ❑ Yes ❑ No Adding more than 50 amps? ❑ Yes ❑ No Type of Use: Type of work: ❑ New ❑ Addition ❑ Service Change ❑ Remodel ❑ Tenant Improvement ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service Property Served by: ❑ Puget Sound Energy ❑ Seattle City Light H: \Applications\Forms- Applications On Line \2011 Applications\Electrical Permit Application Revised 8-9-11 docx Revised. August 2011 bh Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $152.85 (including an attached garage) ❑ Garages, pools, spas and outbuildings $81.90 ea ❑ Low voltage systems (alarm, furnace thermostat) $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES MULTI - FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $63.00 Temporary service (generator) $78.75 ❑ Manufactured/mobile home service $84.00 ❑ Service change or alteration $81.90 (excluding garage or outbuilding) (no added/altered circuits) ❑ Service change with added/altered circuits $81.90 number of added circuits $11.55 ea ❑ Circuits added/altered without service change $54.60 (up to 5 circuits) ❑ Circuits added/altered without service change $54.60 (6 or more circuits) $7.65 ea ❑ Meter /mast repair $68.25 ❑ Low voltage systems $59.85 (alarm, furnace thermostat) ❑ Carnivals $78.75 Number of concessions $10.50 ea TION4INOTE Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWN 1 R ELECTRICAL CONTRACTOR: fIr Signature: Print Name: ),N `^ S■74.A.^.) Q� d Mailing Address: 3f b G-. J-I- S l N K4 j . 1k1 J .�� 1 F' 7 U U 0, � w� W t g_o S (cn City �l State Zip Date: Boa— �� -7 Day Telephone: ?q,/ H:1Applications\Forms- Applications On LinA2011 Applications\Elearical Permit Application Revised 8 -9 -1 l.docx Revised: August 2011 bh Page 2 of 2 • C City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.TukwilaWA.gov RECEIPT Parcel No.: 3324049019 Permit Number: EL11 -1096 Address: 9404 EAST MARGINAL WY S TUKW Status: PENDING Suite No: Applied Date: 12/08/2011 Applicant: MUSEUM OF FLIGHT Issue Date: Receipt No.: R11 -02675 Initials: User ID: Payee: WER 1655 Payment Amount: $78.75 Payment Date: 12/08/2011 03:42 PM Balance: $0.00 ANTHONY STEWART TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 83857H ACCOUNT ITEM LIST: Description 78.75 Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.00 78.75 Total: $78.75 doc: Receiot -06 Printed: 12 -08 -2011 INSPECTION NO. INSPECTION RECORD Retain a copy with permit 64- 1076 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION (� 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: l V of 644 1 Type of Inspection: �� Address. 1144 Date Called: Special Ins ructio : Date Wanted:. /� P a.m: Requester: 1 Phone No: ALApproved per applicable codes. E Corrections required prior to approval. COMMENTS: -/c/- r i:19v Inspector: Date: /210? /r ri REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.