Loading...
HomeMy WebLinkAboutPermit EL11-1130 - WESTFIELD SOUTHCENTER MALL - VANSVANS 811 S OTJTH CENTER MALL EL1 1 -1130 City ofTukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206-431-3665 Web site: http: / /www.TukwilaWA.gov Parcel No.: 9202470010 Address: 811 SOUTHCENTER MALL TUKW Project Name: VANS ELECTRICAL PERMIT Permit Number: EL11 -1130 Issue Date: 02/22/2012 Permit Expires On: 08/20/2012 Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA Contact Person: Name: STARR DE LA CRUZ Address: 2413 PACIFIC COAST HY, SUITE 202 , LOMITA CA Contractor: Name: B B ELECTRIC Address: 2721 S ASH ST , TACOMA WA Contractor License No: BBELEBE950P1 Phone: 310 - 606 -2078 Phone: 253 -573 -1373 Expiration Date: 10/22/2013 DESCRIPTION OF WORK: TENANT IMPROVEMENT: EXISTING ELECTRICAL SERVICE & PANELS, NEW BRANCH CIRCUITS FOR NEW LIGHTING FIXTURES & POWER Value of Electrical: NRES: $20,000.00 RES: $0.00 Type of Fire Protection: UNKNOWN Electrical service provided by: PUGET SOUND ENERGY Fees Collected: $545.63 National Electrical Code Edition: 2008 Permit Center Authorized Signature: t‘..) � Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or t pe • rmance of work. I ' ed to sign and obtain this electrical permit. / Signature: � / Date: 2G i- }6/ Y' Print Name: L3 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/10 EL11 -1130 Printed: 02 -22 -2012 PERMIT CONDITIONS Permit No. EL 11 -1130 * *ELECTRICAL ** 1: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 2: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 3: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 4: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 5: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 6: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. dm: EL -4/10 EL11 -1130 Printed: 02 -22 -2012 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto: //www, ci.tukwila.wa.us Site Address: 2` �►) Tenant Name: V Property Owners Name: Mailing Address: ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print ** { '411 4:t '. 1,3 91 -y'3 f4 7 ! xe i,03 rx 01Ht 3 Eh3 i ! ES'1 gl i' ! it i i Bit 3 `71, vL ii.F . IBak{ a dCl a4 ,o )4.• MAri N coreeepAo► t King Co Assessor's Tax No.: l Suite Number: 54 d4 New Tenant: Floor: 1 ❑.....Yes ❑..No Name: J 6N h tlVtif - J� Mailing Address: 1564-0 N 1i • 1 `1 E -Mail Address: 304 e pie c er • 1 `r E "1 . c dAA n s...7nn�xri n! ^Sk t .,.. Rlidl}C _:ii k� itndtrli: Day Telephone: p *We , /}Z T5O2 City State Fax Number: 662 2'(4 ,c C G' Company Name: ¶ 92 R/ Mailing Address. Contact Person: E -Mail Address: Contractor Registration Number: City Day Telephone: Fax Number: Expiration Date: State Zip Valuation of Project (contractor's bid price): $ ZJ, 000 Scope of Work (please provide detailed information): go WV. 14 Will service be altered? ❑ Yes No Type of Use: Me Ka 11-h (,h4'J Type of work: ❑ New ❑ Addition ❑ Low Voltage 0 Generator Property Served by: ❑ Puget Sound Energy ❑ Seattle City Light Adding more than 50 amps? ❑ Yes No ❑ Service Change ❑ Fire Alarm A lApplicationafformo-Applicanans On Line%2010 Application \7 -2010 -Electrical Permit Application doe bh Page 1 of 2 Remodel ❑ Telecommunication Tenant Improvement ❑ Temporary Service h • • RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $152.85 (including an attached garage) ❑ Garages, pools, spas and outbuildings $81.90 ea ❑ Low voltage systems (alarm, furnace thermostat) $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $81.90 (no added/altered circuits) ❑ Service change with added/altered circuits $81.90 number of added circuits $1155 ea ❑ Circuits added/altered without service change $54.60 (up to 5 circuits) ❑ Circuits added/altered without service change 554.60 (6 or more circuits) $7.65 ea ❑ Meter/mast repair $68.25 ❑ Low voltage systems ....... $59.85 (alarm, furnace thermostat) Iftlii4l;l� �'' MULTI - FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $63.00 ❑ Temporary service (generator) $78.75 ❑ Manufactured/mobile home service $84.00 (excluding garage or outbuilding) ❑ Carnivals $78.75 Number of concessions $10.50 ea Cc.�iySZ := q�;•e! D{Nt4h ti�7ti1�ii1t0, :.1 :,L' '- M"Mf.n.... ll1iL•weu.�_. - -_. % !.inln��} Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: Date: /-2 / d Print Name: W ! ' l l/t Day Telephone: 3 1 0- 10 (per U %64(f7 state Zip Mailing Address: city IDate Application Accepted: Date Application Expires: (e Staff Initials: } Nh \Applicationalfionne- Applications On Lon1201D Applications17 -2010 - Electrical Permit Appliadon.doe Page 2 of 2 ( 1 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov RECEIPT Parcel No.: 9202470010 Permit Number: EL11 -1130 Address: 811 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 12/20/2011 Applicant: VANS Issue Date: Receipt No.: R12 -00742 Initials: User ID: WER 1655 Payment Amount: $436.50 Payment Date: 02/22/2012 11:27 AM Balance: $0.00 Payee: STEVEBN ANDERSON TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 435881 ACCOUNT ITEM LIST: Description 436.50 Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.00 436.50 Total: $436.50 doc: Receipt -06 Printed: 02 -22 -2012 SET RECEIPT RECEIPT NO: R11 -02762 Initials: Payment Date: 12/20/2011 User ID: 1655 Total Payment: 1,514.70 Payee: PERMITS DIRECT SET ID: 122011 SET NAME: VANS SET TRANSACTIONS: Set Member Amount D11 -401 1,332.11 EL11 -1130 109.13 M11 -179 73.46 TOTAL: 1,332.11 TRANSACTION LIST: Type Method Description Amount Payment Check 2154 1,514.70 TOTAL: 1,514.70 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES 000.345.832.00.0 PLAN CHECK - NONRES 000.345.830 TOTAL: 109.13 1,405.57 1,514.70 INSPECTION RECORD 64160 Retain a copy with permit INSPECTfON NO. MIT NO. . . :CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 R. (206) 431 -367 Permit Inspection Request Line (206) 431 -2451 Project: V • Type of Inspection: Ito() Address :. ip Date Called: Special Instructions: • Date Wanted: 311 Requester: Phone No: Approved per applicable codes. EJ Corrections required prior to approval. COMMENTS: Au 60 wi o i s C Date: 03111 ri REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. r. 3 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION (206) 431 -3670 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 431 -2451 Project:` Type of Inspection: 2400 -- -1141 i u+s /111“44 3trs!a /5 Address: '(% Date Called: JW-01-4631/4 1 LLC 441PMCif. LTA- -6& Kt 40105 Special Instructions: . Date Wanted:. 3 r Q...,„n. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: — 1NIar go-by -- -1141 i u+s /111“44 3trs!a /5 K.0. s64-1.--5 4,— PA4JCt-- &K AA 6 4kd 5k( Co41W b+(-5 JW-01-4631/4 1 LLC 441PMCif. LTA- -6& Kt 40105 - t t L-IAtt 4 PA4t-L -15eC i s f, ct;P - COAKeieDuo. - gEt4t4tArrtk611. d4rA . Aka41..-- ••" itisSatJAIE c r ock i-ocd,D ■W l Ft it, WA timirti (Inspector: / 1Date: 63 ,3 /f ❑ REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. C. • F L_ 2- INSPECTION Na INSPECTION RECORD Retain a copy with permit ei4( i/3o PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -36 Permit Inspection Request Line (206) 431 -2451 Project: V 1� Type of Inspection: Address: �� � Ma 41)(../ Called: Special Instructions: Date Wanted:. 24 E. a.m m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: &lot /f)0/11161 Inspector: • Alop (Date: .., /Z,ozi REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. no. .-_....ti.... - __ INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (k-, (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: V ii Type of Inspection: QO, Address: RI 4 / �'V Date Called: / / / /// ecial Instructions: Special p Date Wanted:. 2, p.m Requester: Phone No: EiApproved per applicable codes. aCorrections required prior to approval. COMMENTS: Inspector: "1 (Date: ^' n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. euf- 1130 CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -36 . Permit Inspection Request Line (206) 431 -2451 Project: Type of Inspection: oo� %.gOO1 Address: vi ( • mi t Date Called: - Cl/JbM58 (bNOtjrT Special Instructions: Date Wanted:. IZ (/ ca4rn. Requester: Phone No: Y • Approved per applicable codes. D Corrections required prior to approval. COMMENTS: 7001 - Cl/JbM58 (bNOtjrT x'60 3 • 64,..4 C Roopi (A/A vt,,5 P 9 11 1)5 • pest's /fill 6,114 .// - _yoke (oor /co12tODi‘ AAA / ;Inspector: Date: a z3 2_ :0 •REINSP.ECTION FEE REQUIRED. Prior to next inspection. fee must be paid:at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. • �'r. "y 4 4g a ^hit • .. PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL11 -1130 DATE: 12 -20 -11 PROJECT NAME: VANS SITE ADDRESS: 811 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued EPARTMECNrTS:� (� 741 BulTding Division I I Public Works Fire Prevention Structural Planning Division Permit Coordinator 4 DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 12 -22 -11 Complete Incomplete Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: DATE: DUE DATE: 01 -19-12 Not Approved (attach comments) ❑ Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 Contractors or Tradespeople Prier Friendly Page • Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Business and Licensing Information Name B B ELECTRIC UBI No. 602541064 Phone 2535731373 Status Active Address 2721 S Ash St License No. BBELEBE950P1 Suite /Apt. License Type Electrical Contractor City Tacoma Effective Date 10/21/2005 State WA Expiration Date 10/22/2013 Zip 98409 Suspend Date County Pierce Specialty 1 General Business Type Limited Liability Company Specialty 2 Unused Parent Company S J A ELECTRIC LLC Electrical Administrator INFORMATION License ANDERS'954PE Name ANDERSON, STEVE Status Active Business Owner Information Name Role Effective Date Expiration Date ANDERSON, STEVE J Agent 10/21/2005 10/6/2006 ANDERSON, STEVE Partner /Member 10/21/2005 $250.00 ANDERSON, KIM Partner /Member 10/21/2005 ELECTRICAL CITATION Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 AMERICAN STATES INSURANCE CO 6383316 10/21/2005 Until Cancelled $4,000.00 10/21/2005 Assignment of Savings Information No records found for the previous 6 year period Insurance Information No records found for the previous 6 year period Summons /Complaint Information Summons and Complaints are not filed with the department for this contractor type Warrant Information Warrants are not filed with the department for this contractor type Infractions /Citations Information Infraction / Citation Date RCW Code Type Status Violation Amount EMUTR00191 10/6/2006 19.28.101 RCW ELECTRICAL CITATION Satisfied $250.00 ELEIS00286 3/17/2008 19.28.271 RCW ELECTRICAL CITATION Satisfied $250.00 EBRIC01065 10/12/2007 19.28.101 RCW ELECTRICAL CITATION Satisfied $250.00 https: // fortress .wa.gov /lni/bbip /Print.aspx 02/22/2012 8 KEYED POWER PLAN NOTES 0 0 0 0 0 0 0 0 0 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 J -BOX FOR STOREFRONT SIGN, VIA 7 DAY, 24 -HR TIME CLOCK. VERIFY EXACT LOCATION WITH SIGN INSTALLER. PROVIDE DISCONNECTING MEANS FOR SIGN AS REQUIRED BY THE N.E.C. DUPLEX CONVENIENCE OUTLET MOUNTED IN WALL AT +18" A.F.F. (U.N.O.) DUPLEX CONVENIENCE OUTLET MOUNTED IN SOFFIT AT SHOW WINDOW PER N.E.C. REQUIREMENTS. DEDICATED DUPLEX OUTLET WITH ISOLATED /DEDICATED GROUND MOUNTED IN CASH WRAP FOR COMPUTER / POS SYSTEM. FOUR -PLEX OUTLET MOUNTED IN CASH WRAP FOR DIRTY POWER (GENERAL USE) TEL / DATA BOX MOUNTED IN CASH WRAP WITH 3/4" CONDUIT BACK TO T.T.B. PROVIDE PULL STRING FOR TENANT'S PHONE / DATA INSTALLER'S USE. DUPLEX RECEPTACLE AT 24" A.F.F. BEHIND BACK WRAP FOR DVD PLAYER. SEE TV /DVD OUTLET DETAIL THIS SHEET. 3/4" CONDUIT BETWEEN (2) OUTLET BOXES (ONE AT 24" A.F.F AND ONE AT 78" A.F.F.) FOR T.V. AUDIO / VIDEO CABLES. SEE T.V. /DVD OUTLET DETAIL THIS SHEET. RECESSED SINGLE "CLOCK" OUTLET AT 78" A.F.F. FOR FLAT SCREEN T.V. (ON SAME CIRCUIT AS DVD PLAYER). SEE T.V. /DVD OUTLET DETAIL THIS SHEET. RUN CONDUITS UNDER SLAB FOR CASH WRAP POWER, PHONE AND DATA. J -BOX FOR ANTI THEFT SYSTEM ABOVE SOFFIT. PROVIDE IN ACCESSIBLE LOCATION NEAR ACCESS PANEL. VERIFY DETAILS WITH THE SYSTEM MANUFACTURER. FLUSH J -BOX FOR TRAFFIC COUNTER DEVICE. CENTER OVER OPENING ON THE STORE SIDE OF THE ROLL -UP GRILLE (OR DOORS) RUN 3/4" CONDUIT BACK TO T.T.B. WITH PULL STRING FOR THE SYSTEM INSTALLER'S USE. J -BOX FOR BUZZER / CHIME TRANSFORMER MOUNTED TO WALL IN STOCKROOM (LOCATION PER PLAN). SEE SCHEMATIC THIS SHEET. TRANSFORMER FOR BUZZER / CHIME TRANSFORMER MOUNTED TO WALL IN STOCKROOM (LOC. PER PLAN). SEE SCHEMATIC THIS SHEET. BUZZER MOUNTED TO WALL IN STOCKROOM (LOCATION PER PLAN). SEE SCHEMATIC THIS SHEET. CHIME MOUNTED TO WALL AT 12' -6" A.F.F. OR 6" ABOVE PAINT LINE. (LOCATION PER PLAN) RUN BELL WIRE IN 1/2" CONDIUT TO TRANSFORMER LOCATION. SEE SCHEMATIC THIS SHEET. BUZZER BUTTON AT 42" A.F.F. ON STRIKE SIDE OF SERVICE DOOR ON MALL SIDE. RUN BELL WIRE IN 1/2" CONDUIT TO TRANSFORMER LOCATION. SEE SCHEMATIC THIS SHEET. THE G.0 SHALL INTERCEPT THE TELEPHONE AND DATA CONDUITS WHERE THEY ENTER THE SPACE (V.I.F.) AND EXTEND TO THE T.T.B. LOCATION. WHEN THE T.T.B. IS ON LESS THAN A FULL HT. WALL RUN THE CONDUITS(S) HORZONTALLY IN THE WALL TO THE NEAREST FULL HT. WALL AND STUB OUT AT THE T.T.B. LOCATION. SURFACE MOUNTED & FIRE TREATED 48" X 48" (OR CUT TO FIT SPACE) UN- PAINTED 3/4" PLYWOOD TELEPHONE TERMINAL BOARD (T.T.B.) MOUNT BOTTOM AT 6' A.F.F. OR AS OTHERWISE NOTED. PROVIDE MINIMUM NO. 6 CU. GRD. PER N.E.C. REQUIREMENTS. 4 -PLEX OUTLET MOUNTED ON OR NEAR T.T.B. FOR TELEPHONE / STEREO SYSTEM / SECURITY SYSTEM POWER FLUSH TEL / DATA BOX MOUNTED AT 18" A.F.F. BEHIND MANAGERS DESK WITH 3/4" CONDUIT BACK TO T.T.B. PROVIDE PULL STRING FOR TENANT'S PHONE / DATA INSTALLER'S USE. 4 -PLEX OUTLET AT +18" A.F.F. FOR MANAGER'S DESK USE (2) PROVIDE EACH ON A SEPARATE CIRCUIT DEDICATED DUPLEX OUTLET AT 96" A.F.F. FOR LIGHTED GRAPHIC PANEL. EXIST. DUPLEX G.F.I. OUTLET MOUNTED AT 42" A.F.F. ADJACENT TO TOILET ROOM SINK. RE- CIRCUIT AS SHOWN. (PROVIDE IF NOT EXISTING) EXIST. J -BOX FOR WATER HEATER. PROVIDE NEW IF NOT EXISTING. RE- CIRCUIT AS SHOWN. VERIFY EXACT LOCATION WITH PLUMBING TRADE PRIOR TO ROUGH -IN. EXISTING PANEL 'L'. SEE ONE -LINE DIAGRAM ON SHEET E3. PROVIDE NEW 24/7 TIMECLOCK FOR STOREFRONT LIGHTS AND SIGNAGE, CAT. NO. INTERMATIC #T7401B, 4PST, 120V OR APPROVED EQUAL IF NOT EXISTING. SEE AUTOMATIC LIGHTING CONTROL DIAGRAM ON SHEET E2. NEW SUB -PANEL 'CLS'. SEE ONE -LINE DIAGRAM ON SHEET E3 AND SCHEDULE ON SHEET E2. EXISTING PLYWOOD BACKER BOARD AT ELECTRICAL PANELS TO REMAIN LINE OF TENANT'S MUSIC SYSTEM / COMPUTER RACK ABOVE (BY OTHERS) MOUNTED TO T.T.B. 60A, 208V, 3P WP, DISCONNECT SWITCH FOR COMPLETE CONNECTION OF CONDENSING UNIT (CU -1), 28.1FLA, 208V, 3 -PH. PROVIDE FRN FUSES SIZED PER MANUFACTURER'S SPECIFICATIONS. VERIFY EXACT LOCATION AND COMPLETE REQUIREMENTS WITH MECHANICAL DRAWINGS PRIOR TO ROUGH -IN. 60A, 208V, 3P DISCONNECT SWITCH FOR COMPLETE CONNECTION OF AIR HANDLING UNIT (AHU -1), 1.5HP, 208V, 3 -PH WITH 10KW HEAT. PROVIDE FRN FUSES SIZED PER MANUFACTURER'S SPECIFICATIONS. VERIFY EXACT LOCATION AND COMPLETE REQUIREMENTS WITH MECHANICAL DRAWINGS PRIOR TO ROUGH -IN. PROVIDE J -BOX AND COMPLETE CONNCTION TO DUCT SMOKE DETECTOR. INTERLOCK WITH HVAC UNIT TO PROVIDE SYSTEM SHUTDOWN IF SMOKE IS DETECTED. PROVIDE LOW VOLTAGE TRANSFORMER SIZED AS REQUIRED. VERIFY EXACT LOCATION AND COMPLETE REQUIREMENTS WITH MECHANICAL DRAWINGS. TIE -IN OR PROVIDE CONNECTION TO MALL FIRE ALARM SYSTEM AS REQUIRED. WP, GFI DUPLEX RECEPTACLE WITH "WHILE -IN -USE" COVER FOR HVAC UNIT SERVICING. LOCATE WITHIN 25 FEET OF UNIT. GENERAL POWER PLAN NOTES 1. SEE SHEET E3 FOR GENERAL ELECTRICAL SPECIFICATIONS AND GENERAL ELECTRICAL NOTES. 2. ALL RECEPTACLES, SWITCHES AND COVER PLATES IN THE SALES AREA ARE TO BE WHITE 3. ALL COVER PLATES IN THE STOCK ROOM, CORRIDOR / HALLWAY AND TOILET ROOM ARE TO BE STAINLESS STEEL 4. ALL CONDUITS SHALL BE CONCEALED IN WALLS, OUTLET AND SWITCH BOXES SHALL BE FLUS WITH FINISHED DRYWALL SURFACE UNLESS OTHERWISE NOTED. 5. THE ELECTRICAL CONTRACTOR SHALL PROVIDE A TYPED ELECTRICAL PANEL DIRECTORY AFFIXED TO THE INSIDE OF THE DOOR PANEL. 6. ALLOWANCES ARE TO BE INCLUDED FOR UNFORSEEN CONDITIONS THAT MAY AFFECT THE CONTRACTORS SCOPE OF WORK. MINOR DEVIATIONS REQUIRED FOR ACCOMPLISHING THE INTENT OF THE DESIGN ARE TO BE INCLUDED IN THE ALLOWANCE. 7. ANY EMPTY CONDUITS INSTALLED SHALL BE PROVIDED WITH A PULL STRING. 8. ALL LOW VOLTAGE CABLING FOR DATA, PHONE, AUDIO, VIDEO, ETC IS TO BE FURNISHED AND INSTALLED BY OTHERS AND SHALL BE PLENUM RATED WHEN REQUIRED. ALL SUCH WIRING SHALL BE HELD AS HIGH AS POSSIBLE TO THE DECK, GROUPED TOGETHER AS MUCH AS POSSIBLE, PULLED TIGHT SECURED WITH CABLE TIES AND RUN PARALLEL AND / OR PERPENDICULAR TO THE DEMISING WALLS. NO DIAGIONAL, SAGGING OR RANDOM WIRE RUNS WILL BE APPROVED. 9. THE CONTRACTOR SHALL COORDINATE ALL WORK ABOVE THE CEILING LINE TO PROVIDE THE GREATEST POSSIBLE CLEARANCE FROM THE FLOOR BELOW. 10. DOOR CHIME SYSTEM SHALL INCLUDE ALL WIRING, PUSHBUTTON AND 120/24V TRANSFORMER. VERIFY TONE REQUIRED WITH OWNER PRIOR TO INSTALLATION OF SYSTEM. TRANSFORMER IS TO LOCATED IN ACCESSIBLE CEILING SPACE. INSTALL PLENUM RATED CABLE FOR ALL PORTIONS OF LOW VOLTAGE WIRING. SIZE OF CONDUCTORS TO BE AS RECOMMENDED BY SYSTEM MANUFACTURER. T.V./ DVD OUTLET BUZZER SYSTEM STOCK ROOM SALES AREA SERVICE DOOR ALL WIRING TO BE RUN IN 1/2" E.M.T. +42" w z J 1 0 T.T.B. L -2,4,6 L -8 +96" 23 FILE COPY Porn* No. , 1k1— �l 3Q O rtlfiGW approval Is subject to eiiors and OMISSIoils, -a! of construction documents does not author's .# any adopted code or ordinance. Receipt Ldproved =xd Copy and *Mons Is acknowledged: By Date: City Of Ibkwila NAM ■� -5, J�11.1 Iwo o'dli M ■ ■ 000 000 000 L -1 VIA TIMECLOCK 23 9.6" 0 ELECTRICAL POWER PLAN SCALE: 1/4" = 1' -0" 29 27 26 28 0 REQUIRED : rafotedustioal ectriCal P rnbinp "'"Gas C!ty of Tukwila BL` W ;NG DIVISION No changes R�SK3T� t3r . s sail be made to the scope without Prior approval of Tukwila Building Division. Nom Rvisionss will require a new and Incv plan include additional plan review fees. 6" L -29 i•. L-38,40,42 (E) + + + w 0 0) ABOVE DOOR L-28,30 L -32,3 ,36 OADA NOTES 33 (TIE -I LIGHT SWITCHES, ELECTRICAL OUTLETS, THERMOSTATS AND OTHER ENVIRONMENTAL CONTROLS SHALL HAVE OPERABLE PARTS OF THE CONTROLS LOCATED NO HIGHER THAN 48" AND NO LOWER THAN 15" ABOVE THE FLOOR. IF THE REACH IS OVER AN OBSTRUCTION BETWEEN 20" AND 25" IN DEPTH, THE MAXIMUM HEIGHT IS REDUCED TO 44" FOR FORWARD APPROACH OR 46" FOR SIDE APPROACH, PROVIDED THE OBSTRUCTION IS NO MORE THAN 24" IN DEPTH. OBSTRUCTIONS SHALL NOT EXTEND MORE THAN 25" FROM THE WALL BENEATH A CONTROL. ELlHt3 ELECTRICAL POWER PLAN (Cont.) SCALE: 1 /4" = 1' -0" REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC DEC 2 8 2011 City of Tukwila BUILDING DIVISION RECEIVED DEC 2 0 2011 PERMIT CENTER NP INC. 4115 N. 15TH AVE PHOENIX. AZ 85015 (602) 265 -1559 PROJECT NO, 1 1 1 — 2 31 - - -7 _ E N CO CC ti s E C �'C! QC (I) oa 9 O CO N O L t CCU in`'‘ en • l7 p S z ION E tID I— W z z 0 cc W LJJ Z 6-1 w bb J J W W ■ ; 1 5 7 00 00 co 4-) ea 01 +.• C ajc 11-10: C C t'o Z O a� -0 cis vi 0 N trf REVISIONS: SEAL: DATE: 12 -13 -11 DRAWN BY: NPE FILE NAME: PH 11- 095 -E 1 PROJECT NUMBER: PH11 -095 uJ LU GENERAL LIGHTING PLAN NOTES 1. WIRING FOR EMERGENCY / EXIT & NIGHT LIGHTS SHALL BE AHEAD OF ANY OTHER CONTROLS 2. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATION OF LIGHTING FIXTURES. VERIFY CEILING TYPES AND PROVIDE NECESSARY MOUNTING HARDWARE TO ACCOMMODATE LIGHT FIXTURES USED. 3. ALL LIGHT FIXTURES & LAMPS ARE TO BE SUPPLIED BY THE OWNER AND INSTALLED BY THE GENERAL CONTRACTOR. 4. THE GENERAL CONTRACTOR SHALL SUPPLY ALL UNISTRUT, THREADED ROD AND ATTACHMENT MECHANISMS FOR ANY SUSPENDED LIGHTING FIXTURES AS REQUIRED SUCH AS HI —BAY LIGHTS, TRACK LIGHTS, ETC. 5. ANY LIGHT FIXTURE WITH THE SYMBOL "NL" SHALL BE PROVIDED WITH CONTINIOUS 24 HR. OPERATION AND BE AHEAD OF ANY SWITCHING. 6. THE ELECTRICAL CONTRACTOR SHALL ADJUST (AIM) TRACK HEADS DURING FINAL OWNER WALK —THRU AS DIRECTED BY THE OWNER'S REPRESENTITIVE OR PROJECT MANAGER. KEYED LIGHTING PLAN NOTES O OCCUPANCY SENSOR SWITCHES: RAB #LOS1000 "SMART SWITCH" WHITE 120V. FURNISHED AND INSTALLED BY THE ELECTRICAL CONTRACTOR. E ILLUMINATED EXIT SIGN WITH SELF— CONTAINED BATTERY BACK —UP MINIMUM, 90 MINUTES ILLUMINATION UPON LOSS OF AC POWER. (UNSWITCHED) O EMERGENCY LIGHT WITH SELF — CONTAINED BATTERY BACK —UP, MINIMUM 90 MINUTES ILLUMINATION UPON LOSS OF AC POWER. (UNSWITCHED) O NIGHT LIGHT (NL). UNSWITCHED (TYPICAL) 0 NIGHT LIGHT (NL) /EMERGENCY LIGHT (EM). PROVIDE FIXTURE WITH EMERGENCY BATTERY BACK —UP, MINIMUM 90 MINUTES ILLUMINATION UPON LOSS OF AC POWER. (UNSWITCHED) ADA NOTES LIGHT SWITCHES, ELECTRICAL OUTLETS, THERMOSTATS AND OTHER ENVIRONMENTAL CONTROLS SHALL HAVE OPERABLE PARTS OF THE CONTROLS LOCATED NO HIGHER THAN 48" AND NO LOWER THAN 15" ABOVE THE FLOOR. IF THE REACH IS OVER AN OBSTRUCTION BETWEEN 20" AND 25" IN DEPTH, THE MAXIMUM HEIGHT IS REDUCED TO 44" FOR FORWARD APPROACH OR 46" FOR SIDE APPROACH, PROVIDED THE OBSTRUCTION IS NO MORE THAN 24" IN DEPTH. OBSTRUCTIONS SHALL NOT EXTEND MORE THAN 25" FROM THE WALL BENEATH A CONTROL. LIGHTING CONTROL SCHEMATIC L 120 VOLT CONTROL CIRCUIT "L -23" • • • TC 0 LOAD 1 1 LOAD 2 L_ — i O C3 o b C1 "L "_5,7,9 • STOREFRONT /SIGNAGE• SHOW WINDOW "L "- 1,3,18,20 C2 SALES TRACK• LIGHTS SALES & BACKROOM• LIGHTS "L"-11,13,15,17 0 LIGHTING CONTROL KEYED NOTES 1O LIGHTING CONTACTOR SWITCH 20A, 120V, SINGLE POLE SINGLE THROW. 2O RE —USE EXISTING LIGHTING CONTACTORS IF FEASIBLE. OTHERWISE, PROVIDE NEW LIGHTING CONTACTOR, ELECTRICALLY HELD, 120V COIL IN NEMA 1 ENCLOSURE IF NOT FOUND EXISTING. SIZE NUMBER OF POLES AS REQUIRED. USE SQUARE D "TYPE L" PRODUCTS WITH CAT. NOS. LISTED BELOW: "LG40" (4 POLES), "LG60" (6 POLES), "LG80" (8 POLES), "LG1000" (10 POLES), "LG1200" (12 POLES), 0 BYPASS TIMER SWITCH. ADJUSTABLE 0 -120 MINUTES MAXIMUM. LOCATE NEAR CONTACTOR SWITCHES. 4O PROVIDE NEW TIMECLOCK INTERMATIC CAT. #T7401 B, 4PST, 120V OR APPROVED EQUAL IF NOT EXISTING. NOTES: PRIOR TO MAKING ANY CONDUIT, PIPE OR DUCT —ROOF PENETRATION AND /OR POSITIONING ANY EQUIPMENT ON THE ROOF, ALL THE PROPOSED LOCATIONS AND /OR PENETRATIONS SHALL MATCH LOCATIONS, AS INDICATED ON THE LANDLORD APPROVED PLANS AND BE APPROVED BY LANLORD'S ON —SITE REPRESENTATIVE. ALL TENANT EQUIPMENT ON THE ROOF SHALL BE LABELED WITH TENANT NAME AND SUITE NUMBER. ALL TENANT EQUIPMENT MUST BE LOCATED IN THE LANDLORD APPROVED LOCATION. ALL ROOF PENATRATIONS SHALL BE MADE AT THE TENANT'S EXPENSE BY LANDLORD APPROVED ROOFING CONTRACTOR PER THE LANDLORD SPECIFICATIONS. ALL WATERPROOFING SHALL BE DONE AT THE TENANT'S EXPENSE BY A LANDLORD APPEOVED WATERPROOFING CONSULTANT PER THE LANDLORD SPECIFICATIONS. ON COMPLETEION OF INSTALLATION, TENANT SHALL OBTAIN AT THE TENANT'S EXPENSE, A SPECIAL INSPECTION SIGN —OFF FROM THE LANDLORD'S DESIGNATED ROOFING CONTRACTOR AND SHALL DELIVER PROOF OF SIGN —OFF TO THE LANDLORD TENANT COORDINATOR REPRESENTATIVE ON SITE. z J 0 NOTE: THE ELECTRICAL CONTRACTOR SHALL ADJUST (AIM) TRACK HEADS DURING FINAL OWNER WALK -THRU AS DIRECTED BY THE OWNER'S REPRESENTITIVE OR PROJECT MANAGER. ®m..�_ �. { 1�1 /./ 1:1 1:1= Ill ' '.111 LI 11 1:1 ila 1 NOTE: ALL SALES LIGHTING SHALL BE CONTROLLED THRU TWO LIGHTING CONTACTORS (C1 & C2) THE TEN. G.C. SHALL PROVIDE, INSTALL & WIRE THESE CONTACTORS. L -19�, - __1P -11 IF II 11 TRACK CURRENT LIMITER SUB -PANEL "CLS6M" Breaker # Line Circuit Limit Rating (Amps.) 1 L -5 4 2 L -7 4 3 L -9 3 4 SPARE - 5 SPARE ' - 6 SPARE - JUNO CURRENT LIMITING SUB —PANEL "CLS6M" NOTE: ROUTE ALL TRACK LIGHTING CIRCUITS FROM BREAKER PANEL "L" TO "CLS" LANDING EACH TRACK CIRCUIT ON THE INPUT SIDE OF THE SUPPLEMENTARY BREAKER. 11 11 II II 1 711 1,1,8 II L 1 11 1711 11H8 11 1 I II II III II 11 11 II 1 11 II 11 11 II II 11 1 IL_. II .. i !I 11 11 0 ELECTRICAL LIGHTING PLAN (Cont 0_11-'11,3 REVIEWED .F COMPLIANCE TH NFPA70 - NEC GEC 2 8 2011 ^ill e# Tukwila BUILDING DIVISION 1 1 w1 z J SCALE: 1 /4" = 1' -0" LANDLORD NOTES: MINIMUM CIRCUIT WIRE SIZE SHALL BE #12 AWG EXCLUDING CONTROL WIRING. ALL MAIN AND BRANCH CIRCUIT WARING SHALL BE COPPER. ALL WIRING IS TO HAVE 600 —VOLT INSULATION, TYPE TW, THW, THWN OR THHN FOR MAIN FEEDERS. SAME COLOR SHALL IDENTIFY SAME PHASE THROUGHOUT THE SYSTEM. AT NO TIME CAN FLEXIBLE CONDUIT BE USED AS COMMON ROUTING FOR WIRES. PANEL CONNECTED LOADS WITHIN THE TENANT SPACE AND MAIN FEEDER CONDUCTORS (FROM LANDLORD SWITCHGEAR TO PANEL) SHALL BE BALANCED WITHIN PLUS OR MINUS TEN PERCENT (10 %) ACROSS ALL PHASES. ALL CONDUIT SHALL BE CONCEALED IN FINISHED AREAS. MINIMUM CONDUIT SHALL BE ONE —HALF INCH (1/2 ") DIAMETER AND CONCEALED IN SLAB SHALL BE THREE — QUATER INCH (3/4 "). CO CONDUIT IS ALLOWED TO BE INSTALLED IN THE SLAB UNLESS ABSOLUTELY NECESSARY. COORDINATE ALL IN SLAB WORK WITH LANDLORD'S STRUCTURAL ENGINEER. LANDLORD NOTES: (CONTINUATION) ALL WIRING SHALL BE INSTALLED IN CONDUIT. CONDUIT SHALL BE GALVANIZED STEEL, RIGID HEAVY WALL OR ELECTRICAL METALLIC TUBING. WATERTIGHT FITTINGS SHALL BE USED WHERE REQUIRED BY CODE. CONDUIT HANGERS, CLAMPS, LIGHT FIXTURE SUPPORTS, ETC. SHALL BE FASTENED TO BAR JOISTS OR BEAMS. NO ATTACHMENT OR SUPPORT FROM ANY ROOF DECK IS ALLOWED. EXPOSED CONDUITS SHALL BE IN STRAIGHT LINES OR PARALLEL WITH OR AT RIGHT ANGLES TO COLUMN LINES OR BEAMS AND SEPARATED AT LEAST THREE INCHES (3 ") FROM WATER OR GAS LINE, WHEREVER THEY RUN ALONGSIDE OR ACCROSS SUCH LINE. FLEXIBLE METAL CONDUIT SHALL BE USED ONLY FOR CONNECTIONS INSIDE CASEWORK AND AS THE FINAL CONNECTION FOUR FEET (4' -0 ") MAXIMUM LENGTH, MINMUM ONE —HALF (1 /2 ") ELECTRICAL TRADE SIZE TO RECESSED FIXTURES, MOTORS AND ELECTRICAL EQUIPMENT THAT MAY GENERATE VIBRATION THROUGH THE CONDUIT SYSTEM. NO BX, AC, MC OR ROMEX TYPE WIRING CAN BE ALLOWED. FURNISH LIQUID —TIGHT FLEXIBLE CONDUITS FOR OUTDOOR INSTALLATIONS AND FLOOR BOXES SHALL BE WATERTIGHT WITH CAST THREADED CONDUIT HUBS. PULL BOXES OR JUNCTION BOXWS ARE REQUIRED TO BE OF MINIMUM TWELVE (12) GAUGE GALVANIZED STEEL. BOXES IN WALLS SHALL BE GALVANIZED PRESSED STEEL OR CAST METAL. CAULK AROUND BOXES TO ELIMINATE NOISE TRANSMISSION. THE ELECTRICAL SYSTEM SERVING THE SPACE SHALL BE GROUNDED IN ACCORDANCE WITH THE LATEST REQUIREMENTS OF THE N.E.C. GROUND FAULT CIRCUIT INTERRUPTERS SHALL BE INSTALLED IN BRANCH CIRCUITS, WHERE REQUIRED BY CODE. AS REQUIRED, PROVIDE LOCK —ON DEVICES ON PANEL CIRCUIT BREAKERS FOR EXIT AND EMERGENCY LIGHT AND FIRE /SMOKE ALARM SYSTEM. FURNISH A COMPLETE TYPE WRITTEN IDENTIFICATION DIRECTORY CARD FOR ALL MAIN AND BRANCH CIRCUITS IN THE PANEL DOOR. TENENT'S ELECTRICAL CONTRACTOR SHALL FURNISH AN IDENTIFICATION NAMEPLATE ON TENANT'S MAIN DISCONNECT SWITCH IN LANDLORD'S SWITCHBOARD. NAMEPLATES SHALL BE ONE —EIGHT (1/8 ") THICK PLASTIC, BLACK ON WHITE AND ETCHED LETTERS. THE MINIMUM SIZE SHALL BE ONE INCH (1") WITH ONLY THE TENANT'S SPACE NUMBER ENGRAVED ON SUCH, PERMANENTLY AFFIXED. RECEIVE DEC:. PERMIT CENTER NP INC. 4115 N. 15TH AVE PHOENIX. AZ 85015 (602) 265 -1559 PROJECT NO, 1 1- 2 31 - -- 0 • • • 0 a 157 00 00 00 a V 4 O +- c c cu I, D O O o uO v c 00 a > cNi REVISIONS: SEAL: DATE: 12 -13 -11 DRAWN BY: NPE FILE NAME: PH 11- 095 -E2 PROJECT NUMBER: PH 11 -095 • GENERAL ELECTRICAL NOTES CONTRACTOR SHALL VISIT THE SITE AND FAMILIARIZE HIMSELF WITH THE EXISTING CONDITIONS UNDER WHICH HE IS TO PERFORM HIS WORK. NO ALLOWANCE WILL BE MADE FOR FAILURE TO COMPLY. INFORMATION SHOWN ON PLANS AS EXISTING SHALL BE FIELD VERIFIED BY ELECTRICAL CONTRACTOR. ANY DISCREPANCY SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER FOR CLARIFICATION PRIOR TO STARTING WORK. ALL ELECTRICAL WORK SHALL BE DONE IN ACCORDANCE WITH THE 2008 (LATEST ADOPTED) NATIONAL ELECTRICAL CODE AND ALL APPLICABLE FEDERAL, STATE AND LOCAL CODES AND ORDINANCES. VERIFY EXACT LOCATION, MOUNTING HEIGHT AND ALL ELECTRICAL REQUIREMENTS OF ALL EQUIPMENT PROVIDED BY OTHERS INCLU- DING BUT NOT LIMITED TO HVAC, WATER HEATERS, GENERATORS, ETC. CONTRACTOR SHALL COMPARE NAMEPLATE RATINGS OF EQUIPMENT SUPPLIED WITH THE REQUIREMENTS NOTED ON THESE DRAWINGS AND ADVISE ENGINEER OF ANY DISCREPANCY PRIOR TO ROUGH –IN AND WIRING OF EQUIPMENT. ADDITIONAL EXIT SIGNS AND EMERGENCY LIGHTING MAY BE REQUIRED. ADDITIONAL FIXTURES SHALL BE LOCATED AS DIRECTED BY THE LOCAL BUILDING INSPECTOR OR ARCHITECT. DUPLEX RECEPTACLES MOUNTED WITHIN 6 FEET OF SINK OR LAVATORY SHALL BE GFCI. NEW PANELBOARD(S) SHALL BE BOLT –ON TYPE CIRCUIT BREAKER PANEL, TO MATCH EXISTING PANELBOARDS IN THE PREMISES AS TO MANUFACTURER AND TYPE. THE GROUNDING SYSTEM WITHIN THE PREMISES SHALL BE CONTINUOUS FROM THE SYSTEM GROUND BUSS IN THE LANDLORD'S ELECTRICAL ROOM. WHERE NEW TRANSFORMERS ARE INSTALLED THE TRANSFORMER SECONDARY SHALL BE GROUNDED PER N.E.C. REQUIREMENTS FOR A SEPARATELY DERIVED SYSTEM. ALL WIRING METHODS AND MATERIALS SHALL BE IN ACCORDANCE WITH LOCAL AND NATIONAL CODES IN COMPLIANCE WITH LANDLORD'S REQUIREMENTS. ALL POWER WIRING SHALL BE INSTALLED IN CONDUIT. EMT SHALL BE USED WHERE EXPOSED. CONDUCTOR SHALL BE COPPER WITH TWHN /THHN INSULATION. ROMEX AND BX CABLES ARE NOT ALLOWED. MC SHALL BE ALLOWED WHERE APPROVED BY LANDLORD AND LOCAL AHJ AND WHERE NOT IN PUBLIC VIEW OR EXPOSED. LAYOUT BRANCH CIRCUIT WIRING AND ARRANGEMENT OF HOME RUNS FOR MAXIMUM ECONOMY AND EFFICIENCY. INCREASE WIRE SIZE IF VOLTAGE DROP EXCEEDS 3% OR 100 FEET OF LENGTH. TENANT ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE TO VERIFY ACCURACY OF ELECTRICAL SERVICE AS SHOWN ON THE ONE –LINE DIAGRAM AS WELL AS COORDINATION WITH LOCAL POWER COMPANY. TENANT ELECTRICAL CONTRACTOR TO FIELD VERIFY ALL EXISTING EQUIPMENT AS SHOWN ON DESIGN DRAWINGS AND ARE IN GOOD WORKING CONDITION PRIOR TO RE– USING. IF EXISTING CONDITIONS ARE NOT AS SHOWN OR ARE NOT IN GOOD WORKING CONDITION, CONTRACTOR SHALL PROVIDE EQUIPMENT, CONDUIT AND /OR WIRE AS INDICATED TO PROVIDE A "LIKE –NEW" AND CODE COMPLIANT INSTALLATION. CONTRACTOR IS RESPONSIBLE FOR RELOCATING ANY EXISTING ITEMS BEING REUSED. ANY EQXISTING EQUIPMENT, CONDUIT OR WIRE NOT BEING REUSED SHALL BE REMOVED BY THIS CONTRACTOR. PROPER CLEARANCE MUST BE MAINTAINED ABOUT ELECTRICAL EQUIPMENT PER N.E.C. FIELD VERIFY EXACT MOUNTING SPACE AVAILABLE IN EXISTING ELECTRICAL PRIOR TO INSTALLATION OF NEW ELECTRICAL EQUIPMENT. ALL ELECTRICAL EQUIPMENT SHALL BE ADJUSTED AND TESTED FOR PROPER OPERATION. COMPLETED WIRING SYSTEM SHALL BE FREE FROM SHORT CIRCUIT. ALL PANELBOARDS, SWITCHBOARDS AND LINE VOLTAGE CONTROL EQUIPMENT SHALL BE FIELD MARKED TO WARN QUALIFIED PERSON OF POTENTIAL ELECTRIC ARC FLASH HAZARDS. MARKING SHALL BE LOCATED SO AS TO BE CLEARLY VISIBLE TO QUALIFIED PERSON BEFORE EXAMINATION, ADJUSTING, SERVICING OR MAINTENANCE OF EQUIPMENT. MARKING SHALL BE SELF ADHESIVE, COMMERCIAL LABEL CONFORMING TO N.E.C. 110.16 A.N.S.I. Z535.4 AS MANUFACTURED BY IDEAL OR APPROVED EQUAL. EVERY CIRCUIT AND CIRCUIT MODIFICATION SHALL BE LEGIBLY IDENTIFIED AS TO ITS CLEAR, EVIDENT, AND SPECIFIC PURPOSE OR USE. THE IDENTIFICATION SHALL INCLUDE SUFFICIENT DETAIL TO ALLOW EACH CIRCUIT TO BE DISTINGUISHED FROM ALL OTHERS. THE IDENTIFICATION SHALL BE INCLUDED IN A CIRCUIT DIRECTORY THAT IS LOCATED ON THE FACE OR INSIDE OF THE PANEL DOOR IN THE CASE OF PANELBOARDS AND LOCATED AT EACH SWITCH ON A SWITCHBOARD. PROVIDE WITH NUMBER OF POLES INDICATED OR SPECIFIED. CONTACTORS SHALL BE FURNISHED WITH NEMA 1, SURFACE MOUNTED ENCLOSURES UNLESS CALLED FOR OTHERWISE ON DRAWINGS. EACH CONTACTOR SHALL BE PROVIDED WITH ENGRAVED LAMINATED PLASTIC NAMEPLATE WITH BLACK BACKGROUND AND 1/4" WHITE LETTERS TO DESIGNATE USE OF CONTACTOR. INFORMATION SHOWN ON ONE –LINE DIAGRAM IS BASED ON RECORD DRAWINGS AND /OR LANDLORD INFORMATION. ELECTRICAL CONTRACTOR SHALL VISIT SITE TO VERIFY EXISTING ELECTRICAL CONDITIONS PRIOR TO SUBMITTING BID. BID SHALL INCLUDE ALL COST REQUIRED TO MODIFY EXISTING SYSTEM AS REQUIRED TO ACCOMODATE NEW WORK. ELECTRICAL CONTRACTOR SHALL MAKE ALL FINAL ELECTRICAL CONNECTIONS FOR A COMPLETE ELECTRICAL DISTRIBUTION SYSTEM. 8 FIRE ALARM NOTE 1. TENANT SHALL CONTRACT WITH LANDLORD'S DESIGNATED FIRE ALARM CONTRACTOR FOR DESIGN AND PROGRAMMING. 2. FIRE ALARM CONTRACTOR SHALL CONFIRM COMPLETE FIRE ALARM SYSTEM REQUIREMENTS WITH FIRE MARSHALL OR ANY LOCAL AGENCIES HAVING JURISDICTIONS. A COMPLETE OPERATIONAL AND APPROVED FIRE ALARM SYSTEM FOR THIS PROJECT IS DEEMED PART OF THE FIRE ALARM CONTRACTOR'S CONTRACT. THIS SYSTEM SHALL BE COMPATIBLE WITH THE MALL FIRE ALARM SYSTEM. 3. REUSE ALL EXISTING FIRE ALARM COMPONENTS AND DEVICES WHERE FEASIBLE. OTHERWISE, PROVIDE NEW AS REQUIRED. MATCH EXISTING FIRE ALARM MAKE AND MADE. REUSE OF EXISTING FIRE ALARM SYSTEM IS SUBJECT TO THE APPROVAL OF LANDLORD'S AND BLDG. INSPECTOR. 4. ALL CONNECTIONS AND /OR MODIFICATIONS TO LANDLORD'S FIRE ALARM SYSTEM ARE TO BE COMPLETED BY LANDLORD'S DESIGNATED FIRE ALARM CONTRACTOR AT TENANT EXPENSE. CONTACT MALL MANAGEMENT FOR DETAILS. a ELECTRICAL SYMBOLS (NOT ALL SYMBOLS SHOWN MAY BE USED) DUPLEX CONVENIENCE OUTLET ® +18" A.F.F. U.N.O. -h DUPLEX CONVENIENCE OUTLET, SPLIT WIRED, CAD +18" A.F.F. U.N.O. 1 :.• II EV DUPLEX CONVENIENCE OUTLET CO +42" A.F.F. U.N.O. FOURPLEX RECEPTACLE FLOOR OUTLET SPECIAL OUTLET, VERIFY NEMA CONFIGURATION WITH EQUIPMENT JUNCTION BOX, IN ACCESSIBLE LOCATION JUNCTION BOX IN ACCESSIBLE LOCATION WITH FLEXIBLE CONDUIT CONNECTION TO LIGHTING FIXTURE OR EQUIPMENT AS NOTED TELEPHONE /DATA OUTLET (WITH 3/4" C. STUBBED ABOVE V CEILING U.N.O.) CP +18" A.F.F. ®TELEPHONE OUTLET, FLOOR MOUNTED (STUB 3/4" E.G. ABOVE ACCESSIBLE CEILING V7 DATA OUTLET AT +18" OR AS NOTED. STUB 3/4" E.C. INTO ACCESSIBLE CEILING SPACE. SD DS INDICATES CIRCUIT IN CONDUIT CONCEALED IN OR UNDER FLOOR CONSTRUCTION OR BELOW GRADE INDICATES CIRCUIT IN CONDUIT CONCEALED IN WALL OR CEILING SPACE INDICATES HOMERUN TO PANELBOARD OR AS NOTED. HASH MARKS INDICATE NUMBER OF CONDUCTORS. NO HASH MARKS INDICATES 2 #12 AWG, 1 #12 BOND, 1/2" CONDUIT PANELBOARD DISCONNECT SWITCH - SIZE AND FUSES PER MANUFACTURER'S RECOMMENDATIONS (WEATHER- PROOF WHERE OUTSIDE). THERMOSTAT OUTLET, +48" A.F.F. WITH 4S BOX AND PLASTER RING. MOTOR – SIZE AS INDICATED IN DRAWINGS SINGLE POLE SWITCH H.P. RATED MANUAL MOTOR STARTER WITH THERMAL OVERLOAD PROTECTION. (WEATHERPROOF WHERE OUTSIDE) SMOKE DETECTOR (MATCH EXISTING) DUCT SMOKE DETECTOR (MATCH EXISTING) TIMECLOCK "INTERMATIC, T7401 B. A.F.F. ABOVE FINISHED FLOOR A.D.A. AMERICAN WITH DISABILITIES ACT C. CONDUIT C/B CIRCUIT BREAKER E.C. EMPTY CONDUIT WITH PULL CORD. E.D.F. ELECTRICAL DRINKING REQUIREMENTS) EF EXHAUST FAN F.B.O. FURNISHED BY OTHERS, INSTALLED BY ELECTRICAL CONTRACTOR GFI GROUND FAULT INTERRUPTER GFCI GROUND FAULT CIRCUIT – INTERRUPTER GND GROUND ISO ISOLATED IG ISOLATED GROUND NL NIGHT LIGHT REC RECEPTACLE S.E.S. SERVICE ENTRANCE SECTION T.M.B. TELEPHONE MOUNTING BOARD. 4'Wx8'Hx3 /4 "D PLYWOOD WITH #6 CU. GROUND WIRE TO APPROVED GROUND. FOUNTAIN (VERIFY ROUGH.. -IN T.T.C. TELEPHONE TERMINAL CABINET. 30 "Wx36 "Hx6 "D 16 GA. WEATHERPROOF E/W HINGED LOCKABLE COVER 5/8" PLYWOOD BACKBOARD, PROVIDE A #6 CU. GROUND WIRE TO APPROVED BUILDING GROUND. U.N.O. U/C WH WP XFMR UNLESS NOTED OTHERWISE UNDER COUNTER WATER HEATER WEATHERPROOF (RAINTIGHT) TRANSFORMER PANELBOARDNOTE: PROVIDE A TWO /THREE SINGLE POLE CIRCUIT BREAKERS WITH AN IDENTIFIED HANDLE TIE OR TWO /THREE POLE CIRCUIT BREAKER TO SIMULTANEOUSLY DISCONNECT ALL UNGROUNDED CONDUCTORS OF EACH MULTIWIRE BRANCH CIRCUIT AT THE POINT WHERE THE BRANCH CIRCUIT ORIGINATES AS REQUIRED BY NEC 210.4. LOAD CALCULATIONS LOAD CALCULATIONS LIGHTS at 125% SIGN at 125% OUTLETS, MISC. POWER (1ST 10KVA at 100 %) REMAINDER at 50% WATER HEATER at 100% HVAC: NEW CU -1 at 100% NEW AHU -1 at 100% LARGEST MOTOR at 25% DUCT SMOKE DETECTOR 5,594 1,500 9,600 1,500 (10,116) 12,375 2,250 200 VA VA VA VA VA VA VA VA VA TOTAL DEMAND LOAD TOTAL. AMPS AT 208V, 3Ph, 4W 33,019 VA 92 AMPS PANEL SCHEDULE NOTES PANELBOARD SCHEDULE NOTES: 1 - CONTINUOUS LOAD OR LARGEST MOTOR TAKEN AT 125 %. 2 - THRU 24/7 TIMECLOCK 3 - CIRCUIT BREAKER VVITH LOCK -ON DEVICE. 4 - CIRCUIT BREAKER CAPABLE OF BEING LOCKED IN THE OPEN POSITION 5 - THRU LIGHTING CONTACTOR C1 & C2 SEE LIGHTING CONTROL DIAGRAM ON SHEET E2. 6 - PROVIDE NEW CIRCUIT BREAKER TO MATCH EXISTING MAKE, MODEL, TYPE, RATING, ETC. 7 - NON - COINCIDENTAL LOAD (LARGEST OF CLG /HTG LOAD USED) PANEL SCHEDULE LII - PANELBOARD SCHEDULE ( L 10.000 A.I.C. BREAKER MINIMUM 120 / 208 VOLTS I 3 PHASE I 4 WIRE SURFACE MOUNTED 200A MCB MAINS I EXIST. TYPE NOTE WIRE SIZE USE AND 1 OR AREA SERVED C 1 C LOADS CKT C / B USE AND 1 OR AREA SERVED WIRE SIZE NOTE NO Ph A Ph B 1 Ph C NO 1,2 12 STOREFRONT SIGN 20/1 1 1500 F2 PANEL 'L' 2011 RECEPT - P.O.S. 12 3 6 200 2 1,2 12 LIGHTS - STOREFRONT/SHOW WINDOW 20/1 3 H4* 200 SIMKAR #CH232 –B11 –UNV 4' FLUORESCENT OPEN STRIP LIGHT SUSPEND OR SURFACE MOUNT PER PLAN. EL= PROVIDE EMERGENCY BATTERY PACK EM= CONNECT TO NIGHT LIGHT CIRCUIT (2) PHILIPS F32T8 TL830 ALTO II 32 WATT T8 20/1 RECEPT - P.O.S. 12 3 (4) HILIPS 32T8 TL830 ALTO II 32 WATT T8 4 1,5 12 LIGHTS - SALES TRACK 2011 5 L8 473 CON –TECH LUX BEAM #LB122 SERIES SILVER TRACK HOUSING BEAM (LEGNTH PER PLAN) WITH CON –TECH LT SERIES TRACK SECTION OF MATCHING LENGTH. SPECIFY CURRENT LIMITERS AS NEEDED PER CODE 2011 RECEPT - P.O.S. 12 3 200 6 1,5 12 LIGHTS - SALES TRACK 20/1 7 520 Y 8 2011 RECEPT - CASHWRAP COUNTER 12 #657 (OR EQUAL) RECESSED EXHAUST FAN. SEE MECHANICAL DRAWINGS 12 LIGHTS - SALES TRACK 2011 = 10 20/1 RECEPT - SALES AREA 12 720 12 LIGHTS - SALES AREA 20/1 688 20/1 RECEPT - T.V.IDVD 12 12 LIGHTS - SALES AREA 20/1 13 508 2011 RECEPT - GRAPHIC • 12 1,5 LIGHTS - RT. RM. /REST RM. /CORRIDOR 5 640 20/1 RECEPT - GRAPHIC 12 1,5 12 LIGHTS - OFFICE/STORAGE 20/1 _ 20/1 RECEPT - SHOW WINDOW 12 2 1200 18 1,3 12 LIGHTS - EM/EXIT/NL 20/1 19 1202 2011 RECEPT - SHOW WINDOW 12 2 1200 20 3 12 DUCT SMOKE DETECTOR 2011 21 2011 SPACE 0 22 3 12 TIMECLOCKICONTACTOR 2011 23 500 2011 SECURITY 12 3 500 24 ■■SPARE 4 12 2011 20/1 SPARE 0 26 WATER HEATER 20/1 27 2011 RECEPT - MGRS DESK v12 360 28 12 RECEPT - T.T.B. 20/1 29 360 20/1 RECEPT - MGRS DESK 12 360 30 ■■ ■ 12 SPARE 2014 6013 NEW CU -1 4 6,7 3372 32 RECEPT - STOCK ii • a ._ . •• 20/1 33 - 1080 „ „ 4 6,7 3 34 ■■ SPARE 2011 ' 0 �� 4 6,7 337 36 ■■ SPARE 2014 37 0 38 70/3 NEW AHU -1 4 6,7 4125 ■■ SPACE ■ 39 0 40 4 6,7 4125 SPACE 41 0 4 6,7 412 42 TOTAL LOAD PER PHASE 14058 13276 13551 14058 VA / 120 V = 117 AMPS PANELBOARDNOTE: PROVIDE A TWO /THREE SINGLE POLE CIRCUIT BREAKERS WITH AN IDENTIFIED HANDLE TIE OR TWO /THREE POLE CIRCUIT BREAKER TO SIMULTANEOUSLY DISCONNECT ALL UNGROUNDED CONDUCTORS OF EACH MULTIWIRE BRANCH CIRCUIT AT THE POINT WHERE THE BRANCH CIRCUIT ORIGINATES AS REQUIRED BY NEC 210.4. LOAD CALCULATIONS LOAD CALCULATIONS LIGHTS at 125% SIGN at 125% OUTLETS, MISC. POWER (1ST 10KVA at 100 %) REMAINDER at 50% WATER HEATER at 100% HVAC: NEW CU -1 at 100% NEW AHU -1 at 100% LARGEST MOTOR at 25% DUCT SMOKE DETECTOR 5,594 1,500 9,600 1,500 (10,116) 12,375 2,250 200 VA VA VA VA VA VA VA VA VA TOTAL DEMAND LOAD TOTAL. AMPS AT 208V, 3Ph, 4W 33,019 VA 92 AMPS PANEL SCHEDULE NOTES PANELBOARD SCHEDULE NOTES: 1 - CONTINUOUS LOAD OR LARGEST MOTOR TAKEN AT 125 %. 2 - THRU 24/7 TIMECLOCK 3 - CIRCUIT BREAKER VVITH LOCK -ON DEVICE. 4 - CIRCUIT BREAKER CAPABLE OF BEING LOCKED IN THE OPEN POSITION 5 - THRU LIGHTING CONTACTOR C1 & C2 SEE LIGHTING CONTROL DIAGRAM ON SHEET E2. 6 - PROVIDE NEW CIRCUIT BREAKER TO MATCH EXISTING MAKE, MODEL, TYPE, RATING, ETC. 7 - NON - COINCIDENTAL LOAD (LARGEST OF CLG /HTG LOAD USED) CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO SUBMITTING HIS BID. ANY CHANGES REQUIRED DUE TO INCORRECT EXISTING INFORMATION WILL BE THE CONTRACTOR'S RESPONSIBILITY. 1LWW 1130 IMPORTANT NOTE: EXISTING PANEL 'L' MUST BE SERIES RATED TO UPSTREAM FUSES 22K -10K AIC SYSTEM. ELECTRICAL CONTRACTOR SHALL FIELD VERIFY THIS CONDITION FROM EXISTING PANEL MANUFACTURER PRIOR TO COMMENCEMENT OF WORK. IF PANEL CANNOT BE SERIES RATED, REPLACE EXISTING PANEL AND ITS COMPONENTS WITH NEW. 0 FAULT CURRENT CALCULATIONS FAULT CURRENT CALCULATIONS (THREE PHASE) MARK FAULT ORIGIN POINT OF CALCULATED FAULT FAULT @ ORIGIN AFC1 LINE VOLTS EL CU -MAG =1 CU- NMAG =2 AL -MAG =3 AL- NMAG =4 AL -NM SER =5 WIRE LENGTH L WIRE SIZE NO OF SETS N "C" VALUE If FACTOR "m" FACTOR CALCULATED FAULT AFC2 ** F1 SWITCHBOARD PANEL '1..' 65,000 208 1 82 4/0 1 15082 2.94 0.25 16,500 F2 PANEL 'L' TIMECLOCK 16,500 120 1 6 12 1 617 2.31 0.30 4,980 SERIES RATING NOTES: 1. PROVIDE ENGRAVED NAMEPLATES TO COMPLY WITH NEC - 110 -22 AS FOLLOWS A. NAMEPLATE AT SERVICE SHALL READ: "CAUTION SERIES RATED SYSTEM: 42,000 AMPS AVAILABLE. IDENTIFIED REPLACEMENT COMPONENTS REQUIRED." B. NAMEPLATE AT EACH DOWNSTREAM PANEL'HDP1' TO READ: FOR TWO TIERED SERIES RATED SYSTEMS: "CAUTION - SERIES RATED 42,000 / 14,000 SYSTEM. ** SHORT CIRCUIT AMPS AVAILABLE. IDENTIFIED REPLACEMENT COMPONENTS REQUIRED." 2. NO DESIGN CHANGES MAY BE MADE TO THE SYSTEMS WITHOUT PRIOR APPROVAL FROM THE DESIGN ELECTRIQAL ENGINEER ANp ThE ELECTRICAL INSPECTOR. ** DENOTES CALCULATED FAULTAFC2 ABOVE. NOTE: REFER TO PANELBOARD SCHEDULES FOR PANEL RATING. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO SUBMITTING HIS BID. ANY CHANGES REQUIRED DUE TO INCORRECT EXISTING INFORMATION WILL BE THE CONTRACTOR'S RESPONSIBILITY. 1LWW 1130 IMPORTANT NOTE: EXISTING PANEL 'L' MUST BE SERIES RATED TO UPSTREAM FUSES 22K -10K AIC SYSTEM. ELECTRICAL CONTRACTOR SHALL FIELD VERIFY THIS CONDITION FROM EXISTING PANEL MANUFACTURER PRIOR TO COMMENCEMENT OF WORK. IF PANEL CANNOT BE SERIES RATED, REPLACE EXISTING PANEL AND ITS COMPONENTS WITH NEW. 0 LIGHT FIXTURE SCHEDULE MARK SYMBOL MANUFACTURER / MODEL / DESCRIPTION LAMPS A O JUNO # TM54100E– S– SL /TMP1120SL /TMP1222HZ 100 WATT 12" METAL HALIDE HIGH BAY (1) PHILIPS 100 WATT CMH ED17 MHC100 /U /M /3K /ALTO B2 CONTECH #RAN15038– X2– B -21LBL RECESSED, ADJUSTABLE COMPARTMENTAL LIGHT FIXTURE HOUSING (2) SOLAIS #LR38/25/30/1200 21W. PAR 38 L.E.D. 0 41, B3 CONTECH #RAN15038– X3– B -21LBL RECESSED, ADJUSTABLE COMPARTMENTAL LIGHT FIXTURE HOUSING (3) SOLAIS #LR38/25/30/1200 21W. PAR 38 L.E.D. ;.k 4 c) C CON –TECH #RL38- 21LBL/ 6" RECESSED DOWN LIGHT WITH 21 WATT LABEL. SPECULAR REFLECTOR & WHITE TRIM (1) SOLAIS #LR38/25/30K/21W/ 1275/GY 21W PAR38 LED D _ CONTECH #LT SERIES TRACK (SILVER) LEGNTH PER PLAN. SUPPLY WITH ALL CONNECTORS AND END FEEDS AS REQUIRED. N/A D2,4,6,8,12 E SEASCAPE #THA016X9 BLACK AND WHITE CHECKER "LAMPDHADE" PENDANT FIXTURE W/ WHITE BOTTOM DIFFUSER & CANOPY W/ 3' CORD. (1) TCP, 32 WATT CF SPRING LAMP -28932 l F CON –TECH LIGHTING #CTL838 /2 –U PAR38 ADJUSTABLE TRACK FIXTURE WITH BLACK FINISH. (1) SOLAIS #LR38/25/30K/21 W/ 1275/GY 21W PAR38 LED H4* 11 II SIMKAR #CH232 –B11 –UNV 4' FLUORESCENT OPEN STRIP LIGHT SUSPEND OR SURFACE MOUNT PER PLAN. EL= PROVIDE EMERGENCY BATTERY PACK EM= CONNECT TO NIGHT LIGHT CIRCUIT (2) PHILIPS F32T8 TL830 ALTO II 32 WATT T8 H8* 11 11 SIMKAR #CH2232 –B11 –UNV 8' FLUORESCENT OPEN STRIP LIGHT SUSPEND OR SURFACE MOUNT PER PLAN. EL= PROVIDE EMERGENCY BATTERY PACK EM= CONNECT TO NIGHT LIGHT CIRCUIT (4) HILIPS 32T8 TL830 ALTO II 32 WATT T8 K SIMKAR #JBH- 2- 17 –B11 –UNV WALL MOUNTED FLUORESCENT FIXTURE MOUNTED OVER LAVATORY (2) 17W T8 -24 is L8 CON –TECH LUX BEAM #LB122 SERIES SILVER TRACK HOUSING BEAM (LEGNTH PER PLAN) WITH CON –TECH LT SERIES TRACK SECTION OF MATCHING LENGTH. SPECIFY CURRENT LIMITERS AS NEEDED PER CODE 'LB,4,6,8,12 ' X -EN- BEST LIGHTING #EZXTEU1RW –EM SURFACE MOUNTED THERMOPLASTIC EXIT – WHITE WITH RED LETTERS (LED INCLUDED) X1 BEST LIGHTING #ELXTE– U- 1– RC –A –EM SURFACE MOUNTED EDGE LIT EXIT SIGN WITH UNIVERSAL MOUNTING CANOPY. (CLEAR PANEL – RED LETTERS) 3.2W. L.E.D. (INCLUDED) Y BEST #R1 SURFACE MOUNTED EMERGENCY LIGHTING UNIT WITH SEALED BATTERY BACK –UP (LED INCLUDED) ) #657 (OR EQUAL) RECESSED EXHAUST FAN. SEE MECHANICAL DRAWINGS N/A �!� NOTE: ALL FIXTURES MAY NOT BE USED ON ALL PROJECTS MANUFACTURER TO PROVIDE PERMANENT PRE - PRINTED MAXIMUM RE– LAMPING LABEL PER LIGHTING FIXTURE SCHEDULE * PROVIDE ELECTRONIC NORMAL OTPUT INSTANT START BALLAST PARTIAL ONE LINE DIAGRAM EXIST. LANDLORD DISTRIBUTION SWITCHBOARD 120/208V, 3PH, 4W L.L. SPACE TENANT SPACE REMOVE AND COMPLETELY DISCONNECT EXIST. PANEL AND RETURN TO OWNER /TENANT FOR STORAGE. (NOT USED IN THIS PROJECT) I(\M 1IF– RE –USE EXIST. METER IF L_TJ FEASIBLE, OTHERWISE PROVIDE 1 NEW PER POWER CO. AND ``1 LANDLORD REQUIREMENT E— EXIST. 200A, 3P DISC. SWITCH I I WITH (3) 200A FUSES. c� VERIFY) F1 EXIST. 4 #4/0 CU., 1 # BOND, 2-1/2"C. (FIELD VERIFY) VIE FOR COMPLIANCE H NFPA70 - NEC DEC 282011 City of Walla ILDING DIVISION EXIST. 200A, 3P, MCB L____J PANEL "L" (EXIST.) ONE –LINE DIAGRAM NOTES: 1. THE ELECTRICAL CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO BID. 2. PROVIDE ENGRAVED NAMEPLATES ON EACH SERVICE, PANEL, TRANSFORMER, DISCONNECT SWITCH, MOTOR STARTER, ETC. 3. PROVIDE LISTING OF ALL BREAKERS & LOADS, CLEARLY TYPED AND PERMANENTLY ATTACHED INSIDE THE DOOR OF EACH PANELBOARD. 4. ALL WORK IN LANDLORD'S DISTRIBUTION SECTION SHALL BE PERFORMED BY LANDLORD'S CONTRACTOR AT TENANT EXPENSE. 5. ALL CONDUCTORS SHALL BE COLOR CODED AS REQUIRED BY TEANT CRITERIA MANUAL AND N.E.C. 6. TENANT'S EQUIPMENT IN THE MALL ELECTRIC ROOM MUST BE CLEARLY IDENTIFIED WITH TENANT'S NAME AND SPACE NUMBER. • :i CURRENT LIMITING SUB – PANEL 'CLS' NUMBER OF CONDUITS AS REQUIRED. TO TRACK LIGHTING LOADS 24/7 TIMECLOCK. SEE LIGHTING CONTROL DIAGRAM ON SHEET E2. MIN. 6 FEET WIRE LENGTH RECEIVED DEC 2 0 2011 PERMITCENTEF NENGINEERING INC. 4115 N. 15TH AVE PHOENIX, AZ 85015 (602) 265 -1559 PROJECT NO, 1 I 1 -23 1 zo 0 u u 0oo Z+ • C w o O fl- J LL z o_W g0 Z Q W J _I • • • • • 00 00 na — 00 c C L u �I–r c r. ‘g- �.0 � o o �. - EZ ' Gj CU 0 V Q) Q 00 � V) V'f REVISIONS: i SEAL: DATE: 12 -13 -11 DRAWN BY: NPE FILE NAME: PH11- 095 -E3 PROJECT NUMBER: PH 11 -095 w 2 rn uJ