ELECTRICAL PERMIT
Permit Number: EL11 -1130
Issue Date: 02/22/2012
Permit Expires On: 08/20/2012
Owner:
Name: WESTFIELD PROPERTY TAX DEPT
Address: PO BOX 130940 , CARLSBAD CA
Contact Person:
Name: STARR DE LA CRUZ
Address: 2413 PACIFIC COAST HY, SUITE 202 , LOMITA CA
Contractor:
Name: B B ELECTRIC
Address: 2721 S ASH ST , TACOMA WA
Contractor License No: BBELEBE950P1
Phone: 310 - 606 -2078
Phone: 253 -573 -1373
Expiration Date: 10/22/2013
DESCRIPTION OF WORK:
TENANT IMPROVEMENT: EXISTING ELECTRICAL SERVICE & PANELS, NEW BRANCH CIRCUITS
FOR NEW LIGHTING FIXTURES & POWER
Value of Electrical: NRES: $20,000.00
RES: $0.00
Type of Fire Protection: UNKNOWN
Electrical service provided by: PUGET SOUND ENERGY
Fees Collected:
$545.63
National Electrical Code Edition: 2008
Permit Center Authorized Signature: t‘..) � Date:
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or t pe • rmance of work. I ' ed to sign and obtain this electrical permit. /
Signature: � / Date: 2G i- }6/ Y'
Print Name: L3
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
doc: EL -4/10
EL11 -1130 Printed: 02 -22 -2012
PERMIT CONDITIONS
Permit No. EL 11 -1130
* *ELECTRICAL **
1: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector
at each work site.
2: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector.
3: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter
296 -46B WAC.
4: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the
building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector.
5: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation
of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that
presumes to grant this authority are therefore not valid.
6: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where
approved plans have been issued, revisions to the plans and additional review may be required.
dm: EL -4/10
EL11 -1130 Printed: 02 -22 -2012
CITY OF TUKWILA
Community Development Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
htto: //www, ci.tukwila.wa.us
Site Address: 2` �►)
Tenant Name: V
Property Owners Name:
Mailing Address:
ELECTRICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**Please Print **
{ '411 4:t '. 1,3 91 -y'3 f4 7 ! xe i,03 rx
01Ht 3 Eh3 i ! ES'1 gl i' ! it i i Bit 3 `71, vL ii.F .
IBak{ a dCl a4
,o )4.• MAri
N
coreeepAo►
t
King Co Assessor's Tax No.: l
Suite Number: 54 d4
New Tenant:
Floor: 1
❑.....Yes ❑..No
Name: J 6N h tlVtif - J�
Mailing Address: 1564-0 N 1i
• 1 `1
E -Mail Address: 304 e pie c er • 1 `r E "1 . c dAA
n s...7nn�xri n! ^Sk t
.,.. Rlidl}C _:ii k� itndtrli:
Day Telephone:
p *We , /}Z T5O2
City State
Fax Number: 662 2'(4 ,c C G'
Company Name: ¶ 92 R/
Mailing Address.
Contact Person:
E -Mail Address:
Contractor Registration Number:
City
Day Telephone:
Fax Number:
Expiration Date:
State
Zip
Valuation of Project (contractor's bid price): $ ZJ, 000
Scope of Work (please provide detailed information):
go WV.
14
Will service be altered? ❑ Yes No
Type of Use: Me Ka 11-h (,h4'J
Type of work:
❑ New ❑ Addition
❑ Low Voltage 0 Generator
Property Served by:
❑ Puget Sound Energy
❑ Seattle City Light
Adding more than 50 amps?
❑ Yes No
❑ Service Change
❑ Fire Alarm
A lApplicationafformo-Applicanans On Line%2010 Application \7 -2010 -Electrical Permit Application doe
bh
Page 1 of 2
Remodel
❑ Telecommunication
Tenant Improvement
❑ Temporary Service
h •
•
RESIDENTIAL
NEW RESIDENTIAL SERVICE
❑ New single family dwellings $152.85
(including an attached garage)
❑ Garages, pools, spas and outbuildings $81.90 ea
❑ Low voltage systems
(alarm, furnace thermostat) $59.85 ea
RESIDENTIAL REMODEL AND SERVICE CHANGES
❑ Service change or alteration $81.90
(no added/altered circuits)
❑ Service change with added/altered circuits $81.90
number of added circuits $1155 ea
❑ Circuits added/altered without service change $54.60
(up to 5 circuits)
❑ Circuits added/altered without service change 554.60
(6 or more circuits) $7.65 ea
❑ Meter/mast repair $68.25
❑ Low voltage systems ....... $59.85
(alarm, furnace thermostat)
Iftlii4l;l� �''
MULTI - FAMILY AND COMMERCIAL
Fees are based on the valuation of the electrical contract.
MISCELLANEOUS FEES
❑ Temporary service (residential) $63.00
❑ Temporary service (generator) $78.75
❑ Manufactured/mobile home service $84.00
(excluding garage or outbuilding)
❑ Carnivals $78.75
Number of concessions $10.50 ea
Cc.�iySZ := q�;•e! D{Nt4h ti�7ti1�ii1t0,
:.1 :,L'
'- M"Mf.n.... ll1iL•weu.�_. - -_. % !.inln��}
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing
and justifiable cause demonstrated.
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR ELECTRICAL CONTRACTOR:
Signature:
Date: /-2 / d
Print Name: W ! ' l l/t Day Telephone: 3 1 0- 10 (per U %64(f7
state Zip
Mailing Address:
city
IDate Application Accepted:
Date Application Expires: (e
Staff Initials:
} Nh \Applicationalfionne- Applications On Lon1201D Applications17 -2010 - Electrical Permit Appliadon.doe
Page 2 of 2
( 1
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.TukwilaWA.gov
RECEIPT
Parcel No.: 9202470010 Permit Number: EL11 -1130
Address: 811 SOUTHCENTER MALL TUKW Status: APPROVED
Suite No: Applied Date: 12/20/2011
Applicant: VANS Issue Date:
Receipt No.: R12 -00742
Initials:
User ID:
WER
1655
Payment Amount: $436.50
Payment Date: 02/22/2012 11:27 AM
Balance: $0.00
Payee: STEVEBN ANDERSON
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Credit Crd VISA
Authorization No. 435881
ACCOUNT ITEM LIST:
Description
436.50
Account Code Current Pmts
ELECTRICAL PERMIT - NONR
000.322.101.00.00 436.50
Total: $436.50
doc: Receipt -06 Printed: 02 -22 -2012
SET RECEIPT
RECEIPT NO: R11 -02762
Initials: Payment Date: 12/20/2011
User ID: 1655 Total Payment: 1,514.70
Payee: PERMITS DIRECT
SET ID: 122011 SET NAME: VANS
SET TRANSACTIONS:
Set Member Amount
D11 -401 1,332.11
EL11 -1130 109.13
M11 -179 73.46
TOTAL: 1,332.11
TRANSACTION LIST:
Type Method Description Amount
Payment Check 2154 1,514.70
TOTAL: 1,514.70
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
ELECTRICAL PLAN - NONRES 000.345.832.00.0
PLAN CHECK - NONRES 000.345.830
TOTAL:
109.13
1,405.57
1,514.70
INSPECTION RECORD 64160 Retain a copy with permit
INSPECTfON NO. MIT NO.
. . :CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 R. (206) 431 -367
Permit Inspection Request Line (206) 431 -2451
Project: V
•
Type of Inspection:
Ito()
Address :. ip
Date Called:
Special Instructions: •
Date Wanted:
311
Requester:
Phone No:
Approved per applicable codes. EJ Corrections required prior to approval.
COMMENTS:
Au 60 wi o i s C
Date:
03111
ri REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
r.
3
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
(206) 431 -3670
6300 Southcenter Blvd., #100, Tukwila. WA 98188
Permit Inspection Request Line (206) 431 -2451
Project:`
Type of Inspection:
2400
-- -1141 i u+s /111“44 3trs!a /5
Address: '(%
Date Called:
JW-01-4631/4 1 LLC 441PMCif. LTA-
-6& Kt 40105
Special Instructions:
.
Date Wanted:.
3 r
Q...,„n.
Requester:
Phone No:
Approved per applicable codes.
Corrections required prior to approval.
COMMENTS:
— 1NIar go-by
-- -1141 i u+s /111“44 3trs!a /5
K.0. s64-1.--5 4,— PA4JCt--
&K AA 6 4kd 5k( Co41W b+(-5
JW-01-4631/4 1 LLC 441PMCif. LTA-
-6& Kt 40105
- t t L-IAtt 4 PA4t-L -15eC i s f, ct;P
- COAKeieDuo.
-
gEt4t4tArrtk611. d4rA . Aka41..--
••" itisSatJAIE c r ock i-ocd,D ■W l Ft it, WA timirti
(Inspector: / 1Date: 63
,3 /f
❑ REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.
C.
•
F
L_
2-
INSPECTION Na
INSPECTION RECORD
Retain a copy with permit
ei4( i/3o
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -36
Permit Inspection Request Line (206) 431 -2451
Project: V 1�
Type of Inspection:
Address: �� � Ma 41)(../
Called:
Special Instructions:
Date Wanted:.
24 E.
a.m
m.
Requester:
Phone No:
Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
&lot /f)0/11161
Inspector: •
Alop (Date: .., /Z,ozi
REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.
no. .-_....ti.... - __
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (k-, (206) 431 -3670
Permit Inspection Request Line (206) 431 -2451
Project: V ii
Type of Inspection:
QO,
Address: RI 4 /
�'V
Date Called:
/ / / ///
ecial Instructions:
Special
p
Date Wanted:.
2,
p.m
Requester:
Phone No:
EiApproved per applicable codes.
aCorrections required prior to approval.
COMMENTS:
Inspector:
"1
(Date: ^'
n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
euf- 1130
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -36
. Permit Inspection Request Line (206) 431 -2451
Project:
Type of Inspection:
oo� %.gOO1
Address: vi ( • mi t
Date Called:
- Cl/JbM58 (bNOtjrT
Special Instructions:
Date Wanted:.
IZ
(/
ca4rn.
Requester:
Phone No:
Y •
Approved per applicable codes. D Corrections required prior to approval.
COMMENTS:
7001
- Cl/JbM58 (bNOtjrT
x'60 3
•
64,..4 C Roopi (A/A vt,,5 P
9 11 1)5
• pest's /fill 6,114 .//
- _yoke (oor /co12tODi‘ AAA /
;Inspector:
Date: a z3 2_
:0 •REINSP.ECTION FEE REQUIRED. Prior to next inspection. fee must be
paid:at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
• �'r. "y 4 4g a ^hit •
..
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: EL11 -1130 DATE: 12 -20 -11
PROJECT NAME: VANS
SITE ADDRESS: 811 SOUTHCENTER MALL
X Original Plan Submittal
Response to Correction Letter #
Response to Incomplete Letter #
Revision # After Permit Issued
EPARTMECNrTS:� (� 741
BulTding Division
I I
Public Works
Fire Prevention
Structural
Planning Division
Permit Coordinator
4
DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 12 -22 -11
Complete
Incomplete
Not Applicable
Comments:
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES /THURS ROUTING:
Please Route Structural Review Required
REVIEWER'S INITIALS:
No further Review Required
DATE:
APPROVALS OR CORRECTIONS:
Approved ❑ Approved with Conditions
Notation:
REVIEWER'S INITIALS: DATE:
DUE DATE: 01 -19-12
Not Approved (attach comments) ❑
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents/routing slip.doc
2 -28 -02
Contractors or Tradespeople Prier Friendly Page
•
Electrical Contractor
A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical
Contractors must maintain a surety bond or assignment of savings account. They also must have a
designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time
supervisory employee.
Business and Licensing Information
Name B B ELECTRIC UBI No. 602541064
Phone 2535731373 Status Active
Address 2721 S Ash St License No. BBELEBE950P1
Suite /Apt. License Type Electrical Contractor
City Tacoma Effective Date 10/21/2005
State WA Expiration Date 10/22/2013
Zip 98409 Suspend Date
County Pierce Specialty 1 General
Business Type Limited Liability Company Specialty 2 Unused
Parent Company S J A ELECTRIC LLC
Electrical Administrator INFORMATION
License ANDERS'954PE
Name ANDERSON, STEVE
Status Active
Business Owner Information
Name
Role
Effective Date
Expiration Date
ANDERSON, STEVE J
Agent
10/21/2005
10/6/2006
ANDERSON, STEVE
Partner /Member
10/21/2005
$250.00
ANDERSON, KIM
Partner /Member
10/21/2005
ELECTRICAL CITATION
Bond Information
Page 1 of 1
Bond
Bond Company Name
Bond Account Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Bond Amount
Received Date
1
AMERICAN STATES
INSURANCE CO
6383316
10/21/2005
Until Cancelled
$4,000.00
10/21/2005
Assignment of Savings Information No records found for the previous 6 year period
Insurance Information No records found for the previous 6 year period
Summons /Complaint Information Summons and Complaints are not filed with the department for this contractor type
Warrant Information Warrants are not filed with the department for this contractor type
Infractions /Citations Information
Infraction / Citation
Date
RCW Code
Type
Status
Violation Amount
EMUTR00191
10/6/2006
19.28.101 RCW
ELECTRICAL CITATION
Satisfied
$250.00
ELEIS00286
3/17/2008
19.28.271 RCW
ELECTRICAL CITATION
Satisfied
$250.00
EBRIC01065
10/12/2007
19.28.101 RCW
ELECTRICAL CITATION
Satisfied
$250.00
https: // fortress .wa.gov /lni/bbip /Print.aspx 02/22/2012
8 KEYED POWER PLAN NOTES
0
0
0
0
0
0
0
0
0
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
J -BOX FOR STOREFRONT SIGN, VIA 7 DAY, 24 -HR TIME CLOCK. VERIFY EXACT
LOCATION WITH SIGN INSTALLER. PROVIDE DISCONNECTING MEANS FOR SIGN AS
REQUIRED BY THE N.E.C.
DUPLEX CONVENIENCE OUTLET MOUNTED IN WALL AT +18" A.F.F. (U.N.O.)
DUPLEX CONVENIENCE OUTLET MOUNTED IN SOFFIT AT SHOW WINDOW PER N.E.C.
REQUIREMENTS.
DEDICATED DUPLEX OUTLET WITH ISOLATED /DEDICATED GROUND MOUNTED IN CASH WRAP
FOR COMPUTER / POS SYSTEM.
FOUR -PLEX OUTLET MOUNTED IN CASH WRAP FOR DIRTY POWER (GENERAL USE)
TEL / DATA BOX MOUNTED IN CASH WRAP WITH 3/4" CONDUIT BACK TO T.T.B.
PROVIDE PULL STRING FOR TENANT'S PHONE / DATA INSTALLER'S USE.
DUPLEX RECEPTACLE AT 24" A.F.F. BEHIND BACK WRAP FOR DVD PLAYER. SEE TV /DVD
OUTLET DETAIL THIS SHEET.
3/4" CONDUIT BETWEEN (2) OUTLET BOXES (ONE AT 24" A.F.F AND ONE AT 78" A.F.F.)
FOR T.V. AUDIO / VIDEO CABLES. SEE T.V. /DVD OUTLET DETAIL THIS SHEET.
RECESSED SINGLE "CLOCK" OUTLET AT 78" A.F.F. FOR FLAT SCREEN T.V. (ON SAME
CIRCUIT AS DVD PLAYER). SEE T.V. /DVD OUTLET DETAIL THIS SHEET.
RUN CONDUITS UNDER SLAB FOR CASH WRAP POWER, PHONE AND DATA.
J -BOX FOR ANTI THEFT SYSTEM ABOVE SOFFIT. PROVIDE IN ACCESSIBLE LOCATION NEAR
ACCESS PANEL. VERIFY DETAILS WITH THE SYSTEM MANUFACTURER.
FLUSH J -BOX FOR TRAFFIC COUNTER DEVICE. CENTER OVER OPENING ON THE STORE SIDE
OF THE ROLL -UP GRILLE (OR DOORS) RUN 3/4" CONDUIT BACK TO T.T.B. WITH PULL
STRING FOR THE SYSTEM INSTALLER'S USE.
J -BOX FOR BUZZER / CHIME TRANSFORMER MOUNTED TO WALL IN STOCKROOM (LOCATION
PER PLAN). SEE SCHEMATIC THIS SHEET.
TRANSFORMER FOR BUZZER / CHIME TRANSFORMER MOUNTED TO WALL IN STOCKROOM
(LOC. PER PLAN). SEE SCHEMATIC THIS SHEET.
BUZZER MOUNTED TO WALL IN STOCKROOM (LOCATION PER PLAN). SEE SCHEMATIC
THIS SHEET.
CHIME MOUNTED TO WALL AT 12' -6" A.F.F. OR 6" ABOVE PAINT LINE. (LOCATION PER
PLAN) RUN BELL WIRE IN 1/2" CONDIUT TO TRANSFORMER LOCATION. SEE SCHEMATIC
THIS SHEET.
BUZZER BUTTON AT 42" A.F.F. ON STRIKE SIDE OF SERVICE DOOR ON MALL SIDE. RUN
BELL WIRE IN 1/2" CONDUIT TO TRANSFORMER LOCATION. SEE SCHEMATIC THIS SHEET.
THE G.0 SHALL INTERCEPT THE TELEPHONE AND DATA CONDUITS WHERE THEY ENTER THE
SPACE (V.I.F.) AND EXTEND TO THE T.T.B. LOCATION. WHEN THE T.T.B. IS ON LESS THAN
A FULL HT. WALL RUN THE CONDUITS(S) HORZONTALLY IN THE WALL TO THE NEAREST
FULL HT. WALL AND STUB OUT AT THE T.T.B. LOCATION.
SURFACE MOUNTED & FIRE TREATED 48" X 48" (OR CUT TO FIT SPACE) UN- PAINTED
3/4" PLYWOOD TELEPHONE TERMINAL BOARD (T.T.B.) MOUNT BOTTOM AT 6' A.F.F. OR AS
OTHERWISE NOTED. PROVIDE MINIMUM NO. 6 CU. GRD. PER N.E.C. REQUIREMENTS.
4 -PLEX OUTLET MOUNTED ON OR NEAR T.T.B. FOR TELEPHONE / STEREO SYSTEM /
SECURITY SYSTEM POWER
FLUSH TEL / DATA BOX MOUNTED AT 18" A.F.F. BEHIND MANAGERS DESK WITH 3/4"
CONDUIT BACK TO T.T.B. PROVIDE PULL STRING FOR TENANT'S PHONE / DATA
INSTALLER'S USE.
4 -PLEX OUTLET AT +18" A.F.F. FOR MANAGER'S DESK USE (2) PROVIDE EACH
ON A SEPARATE CIRCUIT
DEDICATED DUPLEX OUTLET AT 96" A.F.F. FOR LIGHTED GRAPHIC PANEL.
EXIST. DUPLEX G.F.I. OUTLET MOUNTED AT 42" A.F.F. ADJACENT TO TOILET ROOM SINK.
RE- CIRCUIT AS SHOWN. (PROVIDE IF NOT EXISTING)
EXIST. J -BOX FOR WATER HEATER. PROVIDE NEW IF NOT EXISTING. RE- CIRCUIT AS SHOWN.
VERIFY EXACT LOCATION WITH PLUMBING TRADE PRIOR TO ROUGH -IN.
EXISTING PANEL 'L'. SEE ONE -LINE DIAGRAM ON SHEET E3.
PROVIDE NEW 24/7 TIMECLOCK FOR STOREFRONT LIGHTS AND SIGNAGE, CAT.
NO. INTERMATIC #T7401B, 4PST, 120V OR APPROVED EQUAL IF NOT EXISTING.
SEE AUTOMATIC LIGHTING CONTROL DIAGRAM ON SHEET E2.
NEW SUB -PANEL 'CLS'. SEE ONE -LINE DIAGRAM ON SHEET E3 AND SCHEDULE ON SHEET
E2.
EXISTING PLYWOOD BACKER BOARD AT ELECTRICAL PANELS TO REMAIN
LINE OF TENANT'S MUSIC SYSTEM / COMPUTER RACK ABOVE (BY OTHERS) MOUNTED TO
T.T.B.
60A, 208V, 3P WP, DISCONNECT SWITCH FOR COMPLETE CONNECTION OF CONDENSING UNIT
(CU -1), 28.1FLA, 208V, 3 -PH. PROVIDE FRN FUSES SIZED PER MANUFACTURER'S
SPECIFICATIONS. VERIFY EXACT LOCATION AND COMPLETE REQUIREMENTS WITH MECHANICAL
DRAWINGS PRIOR TO ROUGH -IN.
60A, 208V, 3P DISCONNECT SWITCH FOR COMPLETE CONNECTION OF AIR HANDLING UNIT
(AHU -1), 1.5HP, 208V, 3 -PH WITH 10KW HEAT. PROVIDE FRN FUSES SIZED PER
MANUFACTURER'S SPECIFICATIONS. VERIFY EXACT LOCATION AND COMPLETE REQUIREMENTS
WITH MECHANICAL DRAWINGS PRIOR TO ROUGH -IN.
PROVIDE J -BOX AND COMPLETE CONNCTION TO DUCT SMOKE DETECTOR. INTERLOCK WITH
HVAC UNIT TO PROVIDE SYSTEM SHUTDOWN IF SMOKE IS DETECTED. PROVIDE LOW
VOLTAGE TRANSFORMER SIZED AS REQUIRED. VERIFY EXACT LOCATION AND COMPLETE
REQUIREMENTS WITH MECHANICAL DRAWINGS. TIE -IN OR PROVIDE CONNECTION TO MALL
FIRE ALARM SYSTEM AS REQUIRED.
WP, GFI DUPLEX RECEPTACLE WITH "WHILE -IN -USE" COVER FOR HVAC UNIT SERVICING.
LOCATE WITHIN 25 FEET OF UNIT.
GENERAL POWER PLAN NOTES
1. SEE SHEET E3 FOR GENERAL ELECTRICAL SPECIFICATIONS AND GENERAL ELECTRICAL NOTES.
2. ALL RECEPTACLES, SWITCHES AND COVER PLATES IN THE SALES AREA ARE TO BE WHITE
3. ALL COVER PLATES IN THE STOCK ROOM, CORRIDOR / HALLWAY AND TOILET ROOM ARE TO
BE STAINLESS STEEL
4. ALL CONDUITS SHALL BE CONCEALED IN WALLS, OUTLET AND SWITCH BOXES SHALL BE FLUS
WITH FINISHED DRYWALL SURFACE UNLESS OTHERWISE NOTED.
5. THE ELECTRICAL CONTRACTOR SHALL PROVIDE A TYPED ELECTRICAL PANEL DIRECTORY
AFFIXED TO THE INSIDE OF THE DOOR PANEL.
6. ALLOWANCES ARE TO BE INCLUDED FOR UNFORSEEN CONDITIONS THAT MAY AFFECT THE
CONTRACTORS SCOPE OF WORK. MINOR DEVIATIONS REQUIRED FOR ACCOMPLISHING THE
INTENT OF THE DESIGN ARE TO BE INCLUDED IN THE ALLOWANCE.
7. ANY EMPTY CONDUITS INSTALLED SHALL BE PROVIDED WITH A PULL STRING.
8. ALL LOW VOLTAGE CABLING FOR DATA, PHONE, AUDIO, VIDEO, ETC IS TO BE FURNISHED AND
INSTALLED BY OTHERS AND SHALL BE PLENUM RATED WHEN REQUIRED. ALL SUCH WIRING
SHALL BE HELD AS HIGH AS POSSIBLE TO THE DECK, GROUPED TOGETHER AS MUCH AS
POSSIBLE, PULLED TIGHT SECURED WITH CABLE TIES AND RUN PARALLEL AND / OR
PERPENDICULAR TO THE DEMISING WALLS. NO DIAGIONAL, SAGGING OR RANDOM WIRE RUNS
WILL BE APPROVED.
9. THE CONTRACTOR SHALL COORDINATE ALL WORK ABOVE THE CEILING LINE TO PROVIDE THE
GREATEST POSSIBLE CLEARANCE FROM THE FLOOR BELOW.
10. DOOR CHIME SYSTEM SHALL INCLUDE ALL WIRING, PUSHBUTTON AND 120/24V TRANSFORMER.
VERIFY TONE REQUIRED WITH OWNER PRIOR TO INSTALLATION OF SYSTEM. TRANSFORMER IS
TO LOCATED IN ACCESSIBLE CEILING SPACE. INSTALL PLENUM RATED CABLE FOR ALL
PORTIONS OF LOW VOLTAGE WIRING. SIZE OF CONDUCTORS TO BE AS RECOMMENDED BY
SYSTEM MANUFACTURER.
T.V./ DVD OUTLET
BUZZER SYSTEM
STOCK ROOM SALES AREA
SERVICE DOOR
ALL WIRING
TO BE RUN IN
1/2" E.M.T.
+42"
w
z
J
1
0
T.T.B.
L -2,4,6
L -8
+96"
23
FILE COPY
Porn* No. , 1k1— �l 3Q
O rtlfiGW approval Is subject to eiiors and OMISSIoils,
-a! of construction documents does not author's
.# any adopted code or ordinance. Receipt
Ldproved =xd Copy and *Mons Is acknowledged:
By
Date:
City Of Ibkwila
NAM
■� -5,
J�11.1
Iwo
o'dli
M
■
■
000 000 000
L -1 VIA
TIMECLOCK
23 9.6"
0 ELECTRICAL POWER PLAN
SCALE: 1/4" = 1' -0"
29 27 26 28
0
REQUIRED :
rafotedustioal
ectriCal
P rnbinp
"'"Gas
C!ty of Tukwila
BL` W ;NG DIVISION
No changes
R�SK3T�
t3r . s sail be made to the scope
without Prior approval of
Tukwila Building Division.
Nom Rvisionss will require a new
and Incv plan include additional plan review fees.
6"
L -29
i•.
L-38,40,42
(E)
+ + +
w 0 0)
ABOVE
DOOR
L-28,30
L -32,3 ,36
OADA NOTES
33 (TIE -I
LIGHT SWITCHES, ELECTRICAL OUTLETS, THERMOSTATS
AND OTHER ENVIRONMENTAL CONTROLS SHALL HAVE
OPERABLE PARTS OF THE CONTROLS LOCATED NO
HIGHER THAN 48" AND NO LOWER THAN 15" ABOVE THE
FLOOR. IF THE REACH IS OVER AN OBSTRUCTION
BETWEEN 20" AND 25" IN DEPTH, THE MAXIMUM HEIGHT
IS REDUCED TO 44" FOR FORWARD APPROACH OR 46"
FOR SIDE APPROACH, PROVIDED THE OBSTRUCTION IS NO
MORE THAN 24" IN DEPTH. OBSTRUCTIONS SHALL NOT
EXTEND MORE THAN 25" FROM THE WALL BENEATH A
CONTROL.
ELlHt3
ELECTRICAL POWER PLAN (Cont.)
SCALE: 1 /4" = 1' -0"
REVIEWED FOR
COMPLIANCE WITH
NFPA 70 - NEC
DEC 2 8 2011
City of Tukwila
BUILDING DIVISION
RECEIVED
DEC 2 0 2011
PERMIT CENTER
NP INC.
4115 N. 15TH AVE
PHOENIX. AZ 85015
(602) 265 -1559
PROJECT NO, 1 1 1 — 2 31
- - -7
_ E
N CO
CC
ti s E
C �'C!
QC (I) oa 9
O
CO
N
O
L
t
CCU
in`'‘
en
•
l7 p
S z
ION
E tID
I—
W
z
z
0
cc
W LJJ
Z
6-1
w
bb
J J
W W
■
; 1 5 7
00
00
co
4-) ea 01
+.• C
ajc
11-10: C C
t'o Z O
a�
-0 cis
vi
0
N trf
REVISIONS:
SEAL:
DATE:
12 -13 -11
DRAWN BY:
NPE
FILE NAME:
PH 11- 095 -E 1
PROJECT NUMBER:
PH11 -095
uJ
LU
GENERAL LIGHTING PLAN NOTES
1. WIRING FOR EMERGENCY / EXIT & NIGHT LIGHTS SHALL BE AHEAD OF ANY OTHER
CONTROLS
2. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATION OF LIGHTING
FIXTURES. VERIFY CEILING TYPES AND PROVIDE NECESSARY MOUNTING HARDWARE
TO ACCOMMODATE LIGHT FIXTURES USED.
3. ALL LIGHT FIXTURES & LAMPS ARE TO BE SUPPLIED BY THE
OWNER AND INSTALLED BY THE GENERAL CONTRACTOR.
4. THE GENERAL CONTRACTOR SHALL SUPPLY ALL UNISTRUT, THREADED ROD AND
ATTACHMENT MECHANISMS FOR ANY SUSPENDED LIGHTING FIXTURES AS REQUIRED
SUCH AS HI —BAY LIGHTS, TRACK LIGHTS, ETC.
5. ANY LIGHT FIXTURE WITH THE SYMBOL "NL" SHALL BE PROVIDED WITH CONTINIOUS
24 HR. OPERATION AND BE AHEAD OF ANY SWITCHING.
6. THE ELECTRICAL CONTRACTOR SHALL ADJUST (AIM) TRACK HEADS DURING FINAL
OWNER WALK —THRU AS DIRECTED BY THE OWNER'S REPRESENTITIVE OR PROJECT
MANAGER.
KEYED LIGHTING PLAN NOTES
O OCCUPANCY SENSOR SWITCHES: RAB #LOS1000 "SMART SWITCH" WHITE 120V.
FURNISHED AND INSTALLED BY THE ELECTRICAL CONTRACTOR.
E ILLUMINATED EXIT SIGN WITH SELF— CONTAINED BATTERY BACK —UP MINIMUM, 90
MINUTES ILLUMINATION UPON LOSS OF AC POWER. (UNSWITCHED)
O EMERGENCY LIGHT WITH SELF — CONTAINED BATTERY BACK —UP, MINIMUM 90
MINUTES ILLUMINATION UPON LOSS OF AC POWER. (UNSWITCHED)
O NIGHT LIGHT (NL). UNSWITCHED (TYPICAL)
0 NIGHT LIGHT (NL) /EMERGENCY LIGHT (EM). PROVIDE FIXTURE WITH EMERGENCY
BATTERY BACK —UP, MINIMUM 90 MINUTES ILLUMINATION UPON LOSS OF AC
POWER. (UNSWITCHED)
ADA NOTES
LIGHT SWITCHES, ELECTRICAL OUTLETS, THERMOSTATS AND OTHER ENVIRONMENTAL
CONTROLS SHALL HAVE OPERABLE PARTS OF THE CONTROLS LOCATED NO HIGHER
THAN 48" AND NO LOWER THAN 15" ABOVE THE FLOOR. IF THE REACH IS OVER AN
OBSTRUCTION BETWEEN 20" AND 25" IN DEPTH, THE MAXIMUM HEIGHT IS REDUCED
TO 44" FOR FORWARD APPROACH OR 46" FOR SIDE APPROACH, PROVIDED THE
OBSTRUCTION IS NO MORE THAN 24" IN DEPTH. OBSTRUCTIONS SHALL NOT EXTEND
MORE THAN 25" FROM THE WALL BENEATH A CONTROL.
LIGHTING CONTROL SCHEMATIC
L
120 VOLT CONTROL CIRCUIT "L -23"
•
•
•
TC
0
LOAD 1
1 LOAD 2
L_ — i
O
C3
o b C1
"L "_5,7,9
•
STOREFRONT /SIGNAGE•
SHOW WINDOW
"L "- 1,3,18,20
C2
SALES TRACK•
LIGHTS
SALES & BACKROOM•
LIGHTS
"L"-11,13,15,17
0 LIGHTING CONTROL KEYED NOTES
1O LIGHTING CONTACTOR SWITCH 20A, 120V, SINGLE POLE SINGLE THROW.
2O RE —USE EXISTING LIGHTING CONTACTORS IF FEASIBLE. OTHERWISE, PROVIDE NEW
LIGHTING CONTACTOR, ELECTRICALLY HELD, 120V COIL IN NEMA 1 ENCLOSURE IF
NOT FOUND EXISTING. SIZE NUMBER OF POLES AS REQUIRED. USE SQUARE D
"TYPE L" PRODUCTS WITH CAT. NOS. LISTED BELOW:
"LG40" (4 POLES),
"LG60" (6 POLES),
"LG80" (8 POLES),
"LG1000" (10 POLES),
"LG1200" (12 POLES),
0 BYPASS TIMER SWITCH. ADJUSTABLE 0 -120 MINUTES MAXIMUM. LOCATE NEAR
CONTACTOR SWITCHES.
4O PROVIDE NEW TIMECLOCK INTERMATIC CAT. #T7401 B, 4PST, 120V OR APPROVED
EQUAL IF NOT EXISTING.
NOTES:
PRIOR TO MAKING ANY CONDUIT, PIPE OR DUCT —ROOF PENETRATION AND /OR
POSITIONING ANY EQUIPMENT ON THE ROOF, ALL THE PROPOSED LOCATIONS AND /OR
PENETRATIONS SHALL MATCH LOCATIONS, AS INDICATED ON THE LANDLORD APPROVED
PLANS AND BE APPROVED BY LANLORD'S ON —SITE REPRESENTATIVE.
ALL TENANT EQUIPMENT ON THE ROOF SHALL BE LABELED WITH TENANT NAME AND
SUITE NUMBER. ALL TENANT EQUIPMENT MUST BE LOCATED IN THE LANDLORD
APPROVED LOCATION. ALL ROOF PENATRATIONS SHALL BE MADE AT THE TENANT'S
EXPENSE BY LANDLORD APPROVED ROOFING CONTRACTOR PER THE LANDLORD
SPECIFICATIONS. ALL WATERPROOFING SHALL BE DONE AT THE TENANT'S EXPENSE BY
A LANDLORD APPEOVED WATERPROOFING CONSULTANT PER THE LANDLORD
SPECIFICATIONS. ON COMPLETEION OF INSTALLATION, TENANT SHALL OBTAIN AT THE
TENANT'S EXPENSE, A SPECIAL INSPECTION SIGN —OFF FROM THE LANDLORD'S
DESIGNATED ROOFING CONTRACTOR AND SHALL DELIVER PROOF OF SIGN —OFF TO THE
LANDLORD TENANT COORDINATOR REPRESENTATIVE ON SITE.
z
J
0
NOTE:
THE ELECTRICAL CONTRACTOR SHALL ADJUST
(AIM) TRACK HEADS DURING FINAL OWNER
WALK -THRU AS DIRECTED BY THE OWNER'S
REPRESENTITIVE OR PROJECT MANAGER.
®m..�_ �.
{
1�1 /./ 1:1
1:1= Ill ' '.111 LI
11 1:1 ila
1
NOTE:
ALL SALES LIGHTING SHALL BE
CONTROLLED THRU TWO LIGHTING
CONTACTORS (C1 & C2) THE TEN.
G.C. SHALL PROVIDE, INSTALL &
WIRE THESE CONTACTORS.
L -19�,
- __1P -11 IF
II 11
TRACK CURRENT LIMITER SUB -PANEL
"CLS6M"
Breaker
#
Line
Circuit
Limit
Rating (Amps.)
1
L -5
4
2
L -7
4
3
L -9
3
4
SPARE
-
5
SPARE '
-
6
SPARE
-
JUNO CURRENT LIMITING SUB —PANEL
"CLS6M"
NOTE:
ROUTE ALL TRACK LIGHTING
CIRCUITS FROM BREAKER PANEL
"L" TO "CLS" LANDING EACH
TRACK CIRCUIT ON THE INPUT
SIDE OF THE SUPPLEMENTARY
BREAKER.
11 11 II II 1
711 1,1,8 II L 1
11 1711 11H8 11 1
I II II III II 11 11 II
1 11 II 11 11 II II 11
1
IL_. II .. i !I 11 11
0 ELECTRICAL LIGHTING PLAN (Cont
0_11-'11,3
REVIEWED .F
COMPLIANCE TH
NFPA70 - NEC
GEC 2 8 2011
^ill e# Tukwila
BUILDING DIVISION 1
1
w1
z
J
SCALE: 1 /4" = 1' -0"
LANDLORD NOTES:
MINIMUM CIRCUIT WIRE SIZE SHALL BE #12
AWG EXCLUDING CONTROL WIRING. ALL
MAIN AND BRANCH CIRCUIT WARING SHALL
BE COPPER. ALL WIRING IS TO HAVE
600 —VOLT INSULATION, TYPE TW, THW,
THWN OR THHN FOR MAIN FEEDERS. SAME
COLOR SHALL IDENTIFY SAME PHASE
THROUGHOUT THE SYSTEM.
AT NO TIME CAN FLEXIBLE CONDUIT BE
USED AS COMMON ROUTING FOR WIRES.
PANEL CONNECTED LOADS WITHIN THE
TENANT SPACE AND MAIN FEEDER
CONDUCTORS (FROM LANDLORD
SWITCHGEAR TO PANEL) SHALL BE
BALANCED WITHIN PLUS OR MINUS TEN
PERCENT (10 %) ACROSS ALL PHASES.
ALL CONDUIT SHALL BE CONCEALED IN
FINISHED AREAS. MINIMUM CONDUIT SHALL
BE ONE —HALF INCH (1/2 ") DIAMETER AND
CONCEALED IN SLAB SHALL BE
THREE — QUATER INCH (3/4 "). CO CONDUIT
IS ALLOWED TO BE INSTALLED IN THE
SLAB UNLESS ABSOLUTELY NECESSARY.
COORDINATE ALL IN SLAB WORK WITH
LANDLORD'S STRUCTURAL ENGINEER.
LANDLORD NOTES: (CONTINUATION)
ALL WIRING SHALL BE INSTALLED IN
CONDUIT. CONDUIT SHALL BE GALVANIZED
STEEL, RIGID HEAVY WALL OR ELECTRICAL
METALLIC TUBING. WATERTIGHT FITTINGS
SHALL BE USED WHERE REQUIRED BY
CODE.
CONDUIT HANGERS, CLAMPS, LIGHT
FIXTURE SUPPORTS, ETC. SHALL BE
FASTENED TO BAR JOISTS OR BEAMS. NO
ATTACHMENT OR SUPPORT FROM ANY
ROOF DECK IS ALLOWED. EXPOSED
CONDUITS SHALL BE IN STRAIGHT LINES
OR PARALLEL WITH OR AT RIGHT ANGLES
TO COLUMN LINES OR BEAMS AND
SEPARATED AT LEAST THREE INCHES (3 ")
FROM WATER OR GAS LINE, WHEREVER
THEY RUN ALONGSIDE OR ACCROSS SUCH
LINE.
FLEXIBLE METAL CONDUIT SHALL BE USED
ONLY FOR CONNECTIONS INSIDE CASEWORK
AND AS THE FINAL CONNECTION FOUR
FEET (4' -0 ") MAXIMUM LENGTH, MINMUM
ONE —HALF (1 /2 ") ELECTRICAL TRADE SIZE
TO RECESSED FIXTURES, MOTORS AND
ELECTRICAL EQUIPMENT THAT MAY
GENERATE VIBRATION THROUGH THE
CONDUIT SYSTEM. NO BX, AC, MC OR
ROMEX TYPE WIRING CAN BE ALLOWED.
FURNISH LIQUID —TIGHT FLEXIBLE CONDUITS
FOR OUTDOOR INSTALLATIONS AND FLOOR
BOXES SHALL BE WATERTIGHT WITH CAST
THREADED CONDUIT HUBS.
PULL BOXES OR JUNCTION BOXWS ARE
REQUIRED TO BE OF MINIMUM TWELVE (12)
GAUGE GALVANIZED STEEL. BOXES IN
WALLS SHALL BE GALVANIZED PRESSED
STEEL OR CAST METAL. CAULK AROUND
BOXES TO ELIMINATE NOISE TRANSMISSION.
THE ELECTRICAL SYSTEM SERVING THE
SPACE SHALL BE GROUNDED IN
ACCORDANCE WITH THE LATEST
REQUIREMENTS OF THE N.E.C.
GROUND FAULT CIRCUIT INTERRUPTERS
SHALL BE INSTALLED IN BRANCH CIRCUITS,
WHERE REQUIRED BY CODE.
AS REQUIRED, PROVIDE LOCK —ON DEVICES
ON PANEL CIRCUIT BREAKERS FOR EXIT
AND EMERGENCY LIGHT AND FIRE /SMOKE
ALARM SYSTEM.
FURNISH A COMPLETE TYPE WRITTEN
IDENTIFICATION DIRECTORY CARD FOR ALL
MAIN AND BRANCH CIRCUITS IN THE
PANEL DOOR.
TENENT'S ELECTRICAL CONTRACTOR SHALL
FURNISH AN IDENTIFICATION NAMEPLATE
ON TENANT'S MAIN DISCONNECT SWITCH IN
LANDLORD'S SWITCHBOARD. NAMEPLATES
SHALL BE ONE —EIGHT (1/8 ") THICK
PLASTIC, BLACK ON WHITE AND ETCHED
LETTERS. THE MINIMUM SIZE SHALL BE
ONE INCH (1") WITH ONLY THE TENANT'S
SPACE NUMBER ENGRAVED ON SUCH,
PERMANENTLY AFFIXED.
RECEIVE
DEC:.
PERMIT CENTER
NP INC.
4115 N. 15TH AVE
PHOENIX. AZ 85015
(602) 265 -1559
PROJECT NO, 1 1- 2 31
- --
0
• • •
0
a
157
00
00
00
a
V 4 O
+-
c c
cu
I,
D O O
o uO v
c 00 a
> cNi
REVISIONS:
SEAL:
DATE:
12 -13 -11
DRAWN BY:
NPE
FILE NAME:
PH 11- 095 -E2
PROJECT NUMBER:
PH 11 -095
•
GENERAL ELECTRICAL NOTES
CONTRACTOR SHALL VISIT THE SITE AND FAMILIARIZE HIMSELF WITH
THE EXISTING CONDITIONS UNDER WHICH HE IS TO PERFORM HIS
WORK. NO ALLOWANCE WILL BE MADE FOR FAILURE TO COMPLY.
INFORMATION SHOWN ON PLANS AS EXISTING SHALL BE FIELD
VERIFIED BY ELECTRICAL CONTRACTOR. ANY DISCREPANCY SHALL BE
BROUGHT TO THE ATTENTION OF THE ENGINEER FOR CLARIFICATION
PRIOR TO STARTING WORK.
ALL ELECTRICAL WORK SHALL BE DONE IN ACCORDANCE WITH THE
2008 (LATEST ADOPTED) NATIONAL ELECTRICAL CODE AND ALL
APPLICABLE FEDERAL, STATE AND LOCAL CODES AND ORDINANCES.
VERIFY EXACT LOCATION, MOUNTING HEIGHT AND ALL ELECTRICAL
REQUIREMENTS OF ALL EQUIPMENT PROVIDED BY OTHERS INCLU-
DING BUT NOT LIMITED TO HVAC, WATER HEATERS, GENERATORS, ETC.
CONTRACTOR SHALL COMPARE NAMEPLATE RATINGS OF EQUIPMENT
SUPPLIED WITH THE REQUIREMENTS NOTED ON THESE DRAWINGS AND
ADVISE ENGINEER OF ANY DISCREPANCY PRIOR TO ROUGH –IN AND
WIRING OF EQUIPMENT.
ADDITIONAL EXIT SIGNS AND EMERGENCY LIGHTING MAY BE REQUIRED.
ADDITIONAL FIXTURES SHALL BE LOCATED AS DIRECTED BY THE
LOCAL BUILDING INSPECTOR OR ARCHITECT.
DUPLEX RECEPTACLES MOUNTED WITHIN 6 FEET OF SINK OR
LAVATORY SHALL BE GFCI.
NEW PANELBOARD(S) SHALL BE BOLT –ON TYPE CIRCUIT BREAKER
PANEL, TO MATCH EXISTING PANELBOARDS IN THE PREMISES AS TO
MANUFACTURER AND TYPE.
THE GROUNDING SYSTEM WITHIN THE PREMISES SHALL BE
CONTINUOUS FROM THE SYSTEM GROUND BUSS IN THE LANDLORD'S
ELECTRICAL ROOM. WHERE NEW TRANSFORMERS ARE INSTALLED THE
TRANSFORMER SECONDARY SHALL BE GROUNDED PER N.E.C.
REQUIREMENTS FOR A SEPARATELY DERIVED SYSTEM.
ALL WIRING METHODS AND MATERIALS SHALL BE IN ACCORDANCE
WITH LOCAL AND NATIONAL CODES IN COMPLIANCE WITH LANDLORD'S
REQUIREMENTS. ALL POWER WIRING SHALL BE INSTALLED IN CONDUIT.
EMT SHALL BE USED WHERE EXPOSED. CONDUCTOR SHALL BE
COPPER WITH TWHN /THHN INSULATION. ROMEX AND BX CABLES ARE
NOT ALLOWED. MC SHALL BE ALLOWED WHERE APPROVED BY
LANDLORD AND LOCAL AHJ AND WHERE NOT IN PUBLIC VIEW OR
EXPOSED.
LAYOUT BRANCH CIRCUIT WIRING AND ARRANGEMENT OF HOME RUNS
FOR MAXIMUM ECONOMY AND EFFICIENCY. INCREASE WIRE SIZE IF
VOLTAGE DROP EXCEEDS 3% OR 100 FEET OF LENGTH.
TENANT ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE TO VERIFY
ACCURACY OF ELECTRICAL SERVICE AS SHOWN ON THE ONE –LINE
DIAGRAM AS WELL AS COORDINATION WITH LOCAL POWER COMPANY.
TENANT ELECTRICAL CONTRACTOR TO FIELD VERIFY ALL EXISTING
EQUIPMENT AS SHOWN ON DESIGN DRAWINGS AND ARE IN GOOD
WORKING CONDITION PRIOR TO RE– USING. IF EXISTING CONDITIONS
ARE NOT AS SHOWN OR ARE NOT IN GOOD WORKING CONDITION,
CONTRACTOR SHALL PROVIDE EQUIPMENT, CONDUIT AND /OR WIRE AS
INDICATED TO PROVIDE A "LIKE –NEW" AND CODE COMPLIANT
INSTALLATION. CONTRACTOR IS RESPONSIBLE FOR RELOCATING ANY
EXISTING ITEMS BEING REUSED. ANY EQXISTING EQUIPMENT, CONDUIT
OR WIRE NOT BEING REUSED SHALL BE REMOVED BY THIS
CONTRACTOR.
PROPER CLEARANCE MUST BE MAINTAINED ABOUT ELECTRICAL
EQUIPMENT PER N.E.C. FIELD VERIFY EXACT MOUNTING SPACE
AVAILABLE IN EXISTING ELECTRICAL PRIOR TO INSTALLATION OF NEW
ELECTRICAL EQUIPMENT.
ALL ELECTRICAL EQUIPMENT SHALL BE ADJUSTED AND TESTED FOR
PROPER OPERATION. COMPLETED WIRING SYSTEM SHALL BE FREE
FROM SHORT CIRCUIT.
ALL PANELBOARDS, SWITCHBOARDS AND LINE VOLTAGE CONTROL
EQUIPMENT SHALL BE FIELD MARKED TO WARN QUALIFIED PERSON OF
POTENTIAL ELECTRIC ARC FLASH HAZARDS. MARKING SHALL BE
LOCATED SO AS TO BE CLEARLY VISIBLE TO QUALIFIED PERSON
BEFORE EXAMINATION, ADJUSTING, SERVICING OR MAINTENANCE OF
EQUIPMENT. MARKING SHALL BE SELF ADHESIVE, COMMERCIAL LABEL
CONFORMING TO N.E.C. 110.16 A.N.S.I. Z535.4 AS MANUFACTURED BY
IDEAL OR APPROVED EQUAL.
EVERY CIRCUIT AND CIRCUIT MODIFICATION SHALL BE LEGIBLY
IDENTIFIED AS TO ITS CLEAR, EVIDENT, AND SPECIFIC PURPOSE OR
USE. THE IDENTIFICATION SHALL INCLUDE SUFFICIENT DETAIL TO
ALLOW EACH CIRCUIT TO BE DISTINGUISHED FROM ALL OTHERS. THE
IDENTIFICATION SHALL BE INCLUDED IN A CIRCUIT DIRECTORY THAT IS
LOCATED ON THE FACE OR INSIDE OF THE PANEL DOOR IN THE CASE
OF PANELBOARDS AND LOCATED AT EACH SWITCH ON A
SWITCHBOARD.
PROVIDE WITH NUMBER OF POLES INDICATED OR SPECIFIED.
CONTACTORS SHALL BE FURNISHED WITH NEMA 1, SURFACE MOUNTED
ENCLOSURES UNLESS CALLED FOR OTHERWISE ON DRAWINGS. EACH
CONTACTOR SHALL BE PROVIDED WITH ENGRAVED LAMINATED PLASTIC
NAMEPLATE WITH BLACK BACKGROUND AND 1/4" WHITE LETTERS TO
DESIGNATE USE OF CONTACTOR.
INFORMATION SHOWN ON ONE –LINE DIAGRAM IS BASED ON RECORD
DRAWINGS AND /OR LANDLORD INFORMATION. ELECTRICAL CONTRACTOR
SHALL VISIT SITE TO VERIFY EXISTING ELECTRICAL CONDITIONS PRIOR
TO SUBMITTING BID. BID SHALL INCLUDE ALL COST REQUIRED TO
MODIFY EXISTING SYSTEM AS REQUIRED TO ACCOMODATE NEW WORK.
ELECTRICAL CONTRACTOR SHALL MAKE ALL FINAL ELECTRICAL
CONNECTIONS FOR A COMPLETE ELECTRICAL DISTRIBUTION SYSTEM.
8 FIRE ALARM NOTE
1. TENANT SHALL CONTRACT WITH LANDLORD'S DESIGNATED FIRE ALARM
CONTRACTOR FOR DESIGN AND PROGRAMMING.
2. FIRE ALARM CONTRACTOR SHALL CONFIRM COMPLETE FIRE ALARM
SYSTEM REQUIREMENTS WITH FIRE MARSHALL OR ANY LOCAL
AGENCIES HAVING JURISDICTIONS. A COMPLETE OPERATIONAL AND
APPROVED FIRE ALARM SYSTEM FOR THIS PROJECT IS DEEMED PART
OF THE FIRE ALARM CONTRACTOR'S CONTRACT. THIS SYSTEM SHALL
BE COMPATIBLE WITH THE MALL FIRE ALARM SYSTEM.
3. REUSE ALL EXISTING FIRE ALARM COMPONENTS AND DEVICES WHERE
FEASIBLE. OTHERWISE, PROVIDE NEW AS REQUIRED. MATCH EXISTING
FIRE ALARM MAKE AND MADE. REUSE OF EXISTING FIRE ALARM
SYSTEM IS SUBJECT TO THE APPROVAL OF LANDLORD'S AND BLDG.
INSPECTOR.
4. ALL CONNECTIONS AND /OR MODIFICATIONS TO LANDLORD'S FIRE
ALARM SYSTEM ARE TO BE COMPLETED BY LANDLORD'S DESIGNATED
FIRE ALARM CONTRACTOR AT TENANT EXPENSE. CONTACT MALL
MANAGEMENT FOR DETAILS.
a ELECTRICAL SYMBOLS
(NOT ALL SYMBOLS SHOWN MAY BE USED)
DUPLEX CONVENIENCE OUTLET ® +18" A.F.F. U.N.O.
-h DUPLEX CONVENIENCE OUTLET, SPLIT WIRED, CAD +18"
A.F.F. U.N.O.
1
:.•
II EV
DUPLEX CONVENIENCE OUTLET CO +42" A.F.F. U.N.O.
FOURPLEX RECEPTACLE
FLOOR OUTLET
SPECIAL OUTLET, VERIFY NEMA CONFIGURATION WITH
EQUIPMENT
JUNCTION BOX, IN ACCESSIBLE LOCATION
JUNCTION BOX IN ACCESSIBLE LOCATION WITH
FLEXIBLE CONDUIT CONNECTION TO LIGHTING
FIXTURE OR EQUIPMENT AS NOTED
TELEPHONE /DATA OUTLET (WITH 3/4" C. STUBBED ABOVE
V CEILING U.N.O.) CP +18" A.F.F.
®TELEPHONE OUTLET, FLOOR MOUNTED (STUB 3/4"
E.G. ABOVE ACCESSIBLE CEILING
V7 DATA OUTLET AT +18" OR AS NOTED. STUB 3/4" E.C.
INTO ACCESSIBLE CEILING SPACE.
SD
DS
INDICATES CIRCUIT IN CONDUIT CONCEALED IN OR
UNDER FLOOR CONSTRUCTION OR BELOW GRADE
INDICATES CIRCUIT IN CONDUIT CONCEALED IN WALL
OR CEILING SPACE
INDICATES HOMERUN TO PANELBOARD OR AS NOTED.
HASH MARKS INDICATE NUMBER OF CONDUCTORS.
NO HASH MARKS INDICATES 2 #12 AWG, 1 #12 BOND,
1/2" CONDUIT
PANELBOARD
DISCONNECT SWITCH - SIZE AND FUSES PER
MANUFACTURER'S RECOMMENDATIONS (WEATHER-
PROOF WHERE OUTSIDE).
THERMOSTAT OUTLET, +48" A.F.F. WITH 4S BOX AND
PLASTER RING.
MOTOR – SIZE AS INDICATED IN DRAWINGS
SINGLE POLE SWITCH
H.P. RATED MANUAL MOTOR STARTER WITH THERMAL
OVERLOAD PROTECTION. (WEATHERPROOF WHERE
OUTSIDE)
SMOKE DETECTOR (MATCH EXISTING)
DUCT SMOKE DETECTOR (MATCH EXISTING)
TIMECLOCK "INTERMATIC, T7401 B.
A.F.F. ABOVE FINISHED FLOOR
A.D.A. AMERICAN WITH DISABILITIES ACT
C. CONDUIT
C/B CIRCUIT BREAKER
E.C. EMPTY CONDUIT WITH PULL CORD.
E.D.F. ELECTRICAL DRINKING
REQUIREMENTS)
EF EXHAUST FAN
F.B.O. FURNISHED BY OTHERS, INSTALLED BY ELECTRICAL
CONTRACTOR
GFI GROUND FAULT INTERRUPTER
GFCI GROUND FAULT CIRCUIT – INTERRUPTER
GND GROUND
ISO ISOLATED
IG ISOLATED GROUND
NL NIGHT LIGHT
REC RECEPTACLE
S.E.S. SERVICE ENTRANCE SECTION
T.M.B. TELEPHONE MOUNTING BOARD. 4'Wx8'Hx3 /4 "D
PLYWOOD WITH #6 CU. GROUND WIRE TO APPROVED
GROUND.
FOUNTAIN (VERIFY ROUGH.. -IN
T.T.C. TELEPHONE TERMINAL CABINET. 30 "Wx36 "Hx6 "D
16 GA. WEATHERPROOF E/W HINGED LOCKABLE
COVER 5/8" PLYWOOD BACKBOARD, PROVIDE
A #6 CU. GROUND WIRE TO APPROVED BUILDING
GROUND.
U.N.O.
U/C
WH
WP
XFMR
UNLESS NOTED OTHERWISE
UNDER COUNTER
WATER HEATER
WEATHERPROOF (RAINTIGHT)
TRANSFORMER
PANELBOARDNOTE:
PROVIDE A TWO /THREE SINGLE POLE CIRCUIT BREAKERS WITH AN IDENTIFIED HANDLE TIE OR TWO /THREE POLE
CIRCUIT BREAKER TO SIMULTANEOUSLY DISCONNECT ALL UNGROUNDED CONDUCTORS OF EACH MULTIWIRE
BRANCH CIRCUIT AT THE POINT WHERE THE BRANCH CIRCUIT ORIGINATES AS REQUIRED BY NEC 210.4.
LOAD CALCULATIONS
LOAD CALCULATIONS
LIGHTS at 125%
SIGN at 125%
OUTLETS, MISC. POWER (1ST 10KVA at 100 %)
REMAINDER at 50%
WATER HEATER at 100%
HVAC:
NEW CU -1 at 100%
NEW AHU -1 at 100%
LARGEST MOTOR at 25%
DUCT SMOKE DETECTOR
5,594
1,500
9,600
1,500
(10,116)
12,375
2,250
200
VA
VA
VA
VA
VA
VA
VA
VA
VA
TOTAL DEMAND LOAD
TOTAL. AMPS AT 208V, 3Ph, 4W
33,019 VA
92 AMPS
PANEL SCHEDULE NOTES
PANELBOARD SCHEDULE NOTES:
1 - CONTINUOUS LOAD OR LARGEST MOTOR TAKEN AT 125 %.
2 - THRU 24/7 TIMECLOCK
3 - CIRCUIT BREAKER VVITH LOCK -ON DEVICE.
4 - CIRCUIT BREAKER CAPABLE OF BEING LOCKED IN THE
OPEN POSITION
5 - THRU LIGHTING CONTACTOR C1 & C2
SEE LIGHTING CONTROL DIAGRAM
ON SHEET E2.
6 - PROVIDE NEW CIRCUIT BREAKER TO
MATCH EXISTING MAKE, MODEL, TYPE,
RATING, ETC.
7 - NON - COINCIDENTAL LOAD
(LARGEST OF CLG /HTG LOAD USED)
PANEL SCHEDULE
LII
-
PANELBOARD SCHEDULE (
L 10.000 A.I.C. BREAKER MINIMUM
120 / 208 VOLTS I 3 PHASE I 4 WIRE
SURFACE MOUNTED
200A MCB MAINS I EXIST. TYPE
NOTE
WIRE
SIZE
USE AND 1 OR AREA SERVED
C 1
C
LOADS
CKT
C / B
USE AND 1 OR AREA SERVED
WIRE
SIZE
NOTE
NO
Ph A
Ph B 1 Ph C
NO
1,2
12
STOREFRONT SIGN
20/1
1
1500
F2
PANEL 'L'
2011
RECEPT - P.O.S.
12
3
6
200
2
1,2
12
LIGHTS - STOREFRONT/SHOW WINDOW
20/1
3
H4*
200
SIMKAR #CH232 –B11 –UNV 4' FLUORESCENT OPEN
STRIP LIGHT SUSPEND OR SURFACE MOUNT PER PLAN.
EL= PROVIDE EMERGENCY BATTERY PACK EM= CONNECT
TO NIGHT LIGHT CIRCUIT
(2) PHILIPS
F32T8 TL830 ALTO II
32 WATT T8
20/1
RECEPT - P.O.S.
12
3
(4) HILIPS
32T8 TL830 ALTO II
32 WATT T8
4
1,5
12
LIGHTS - SALES TRACK
2011
5
L8
473
CON –TECH LUX BEAM #LB122 SERIES SILVER TRACK
HOUSING BEAM (LEGNTH PER PLAN) WITH CON –TECH
LT SERIES TRACK SECTION OF MATCHING LENGTH.
SPECIFY CURRENT LIMITERS AS NEEDED PER CODE
2011
RECEPT - P.O.S.
12
3
200
6
1,5
12
LIGHTS - SALES TRACK
20/1
7
520
Y
8
2011
RECEPT - CASHWRAP COUNTER
12
#657 (OR EQUAL) RECESSED EXHAUST FAN.
SEE MECHANICAL DRAWINGS
12
LIGHTS - SALES TRACK
2011
=
10
20/1
RECEPT - SALES AREA
12
720
12
LIGHTS - SALES AREA
20/1
688
20/1
RECEPT - T.V.IDVD
12
12
LIGHTS - SALES AREA
20/1
13
508
2011
RECEPT - GRAPHIC •
12
1,5
LIGHTS - RT. RM. /REST RM. /CORRIDOR
5
640
20/1
RECEPT - GRAPHIC
12
1,5
12
LIGHTS - OFFICE/STORAGE
20/1
_
20/1
RECEPT - SHOW WINDOW
12
2
1200
18
1,3
12
LIGHTS - EM/EXIT/NL
20/1
19
1202
2011
RECEPT - SHOW WINDOW
12
2
1200
20
3
12
DUCT SMOKE DETECTOR
2011
21
2011
SPACE
0
22
3
12
TIMECLOCKICONTACTOR
2011
23
500
2011
SECURITY
12
3
500
24
■■SPARE
4
12
2011
20/1
SPARE
0
26
WATER HEATER
20/1
27
2011
RECEPT - MGRS DESK
v12
360
28
12
RECEPT - T.T.B.
20/1
29
360
20/1
RECEPT - MGRS DESK
12
360
30
■■
■ 12
SPARE
2014
6013
NEW CU -1
4
6,7
3372
32
RECEPT - STOCK
ii • a ._ . ••
20/1
33
-
1080
„
„
4
6,7
3
34
■■
SPARE
2011 '
0
��
4
6,7
337
36
■■
SPARE
2014
37
0
38
70/3
NEW AHU -1
4
6,7
4125
■■
SPACE
■
39
0
40
4
6,7
4125
SPACE
41
0
4
6,7
412
42
TOTAL LOAD PER PHASE
14058 13276
13551
14058 VA / 120 V = 117 AMPS
PANELBOARDNOTE:
PROVIDE A TWO /THREE SINGLE POLE CIRCUIT BREAKERS WITH AN IDENTIFIED HANDLE TIE OR TWO /THREE POLE
CIRCUIT BREAKER TO SIMULTANEOUSLY DISCONNECT ALL UNGROUNDED CONDUCTORS OF EACH MULTIWIRE
BRANCH CIRCUIT AT THE POINT WHERE THE BRANCH CIRCUIT ORIGINATES AS REQUIRED BY NEC 210.4.
LOAD CALCULATIONS
LOAD CALCULATIONS
LIGHTS at 125%
SIGN at 125%
OUTLETS, MISC. POWER (1ST 10KVA at 100 %)
REMAINDER at 50%
WATER HEATER at 100%
HVAC:
NEW CU -1 at 100%
NEW AHU -1 at 100%
LARGEST MOTOR at 25%
DUCT SMOKE DETECTOR
5,594
1,500
9,600
1,500
(10,116)
12,375
2,250
200
VA
VA
VA
VA
VA
VA
VA
VA
VA
TOTAL DEMAND LOAD
TOTAL. AMPS AT 208V, 3Ph, 4W
33,019 VA
92 AMPS
PANEL SCHEDULE NOTES
PANELBOARD SCHEDULE NOTES:
1 - CONTINUOUS LOAD OR LARGEST MOTOR TAKEN AT 125 %.
2 - THRU 24/7 TIMECLOCK
3 - CIRCUIT BREAKER VVITH LOCK -ON DEVICE.
4 - CIRCUIT BREAKER CAPABLE OF BEING LOCKED IN THE
OPEN POSITION
5 - THRU LIGHTING CONTACTOR C1 & C2
SEE LIGHTING CONTROL DIAGRAM
ON SHEET E2.
6 - PROVIDE NEW CIRCUIT BREAKER TO
MATCH EXISTING MAKE, MODEL, TYPE,
RATING, ETC.
7 - NON - COINCIDENTAL LOAD
(LARGEST OF CLG /HTG LOAD USED)
CONTRACTOR SHALL FIELD VERIFY ALL EXISTING
CONDITIONS PRIOR TO SUBMITTING HIS BID. ANY
CHANGES REQUIRED DUE TO INCORRECT EXISTING
INFORMATION WILL BE THE CONTRACTOR'S
RESPONSIBILITY.
1LWW 1130
IMPORTANT NOTE:
EXISTING PANEL 'L' MUST BE SERIES RATED TO
UPSTREAM FUSES 22K -10K AIC SYSTEM.
ELECTRICAL CONTRACTOR SHALL FIELD VERIFY
THIS CONDITION FROM EXISTING PANEL
MANUFACTURER PRIOR TO COMMENCEMENT OF
WORK. IF PANEL CANNOT BE SERIES RATED,
REPLACE EXISTING PANEL AND ITS COMPONENTS
WITH NEW.
0
FAULT CURRENT CALCULATIONS
FAULT CURRENT CALCULATIONS (THREE PHASE)
MARK
FAULT
ORIGIN
POINT OF
CALCULATED
FAULT
FAULT @
ORIGIN
AFC1
LINE
VOLTS
EL
CU -MAG =1
CU- NMAG =2
AL -MAG =3
AL- NMAG =4
AL -NM SER =5
WIRE
LENGTH
L
WIRE
SIZE
NO OF
SETS
N
"C"
VALUE
If
FACTOR
"m"
FACTOR
CALCULATED
FAULT
AFC2 **
F1
SWITCHBOARD
PANEL '1..'
65,000
208
1
82
4/0
1
15082
2.94
0.25
16,500
F2
PANEL 'L'
TIMECLOCK
16,500
120
1
6
12
1
617
2.31
0.30
4,980
SERIES RATING NOTES:
1. PROVIDE ENGRAVED NAMEPLATES TO COMPLY WITH NEC - 110 -22 AS FOLLOWS
A. NAMEPLATE AT SERVICE SHALL READ: "CAUTION SERIES RATED SYSTEM: 42,000 AMPS AVAILABLE. IDENTIFIED REPLACEMENT
COMPONENTS REQUIRED."
B. NAMEPLATE AT EACH DOWNSTREAM PANEL'HDP1' TO READ:
FOR TWO TIERED SERIES RATED SYSTEMS:
"CAUTION - SERIES RATED 42,000 / 14,000 SYSTEM.
** SHORT CIRCUIT AMPS AVAILABLE. IDENTIFIED REPLACEMENT COMPONENTS REQUIRED."
2. NO DESIGN CHANGES MAY BE MADE TO THE SYSTEMS WITHOUT PRIOR APPROVAL FROM THE DESIGN ELECTRIQAL ENGINEER ANp ThE ELECTRICAL
INSPECTOR.
** DENOTES CALCULATED FAULTAFC2 ABOVE.
NOTE: REFER TO PANELBOARD SCHEDULES FOR PANEL RATING.
CONTRACTOR SHALL FIELD VERIFY ALL EXISTING
CONDITIONS PRIOR TO SUBMITTING HIS BID. ANY
CHANGES REQUIRED DUE TO INCORRECT EXISTING
INFORMATION WILL BE THE CONTRACTOR'S
RESPONSIBILITY.
1LWW 1130
IMPORTANT NOTE:
EXISTING PANEL 'L' MUST BE SERIES RATED TO
UPSTREAM FUSES 22K -10K AIC SYSTEM.
ELECTRICAL CONTRACTOR SHALL FIELD VERIFY
THIS CONDITION FROM EXISTING PANEL
MANUFACTURER PRIOR TO COMMENCEMENT OF
WORK. IF PANEL CANNOT BE SERIES RATED,
REPLACE EXISTING PANEL AND ITS COMPONENTS
WITH NEW.
0
LIGHT FIXTURE SCHEDULE
MARK
SYMBOL
MANUFACTURER / MODEL / DESCRIPTION
LAMPS
A
O
JUNO # TM54100E– S– SL /TMP1120SL /TMP1222HZ
100 WATT 12" METAL HALIDE HIGH BAY
(1) PHILIPS
100 WATT CMH ED17
MHC100 /U /M /3K /ALTO
B2
CONTECH #RAN15038– X2– B -21LBL RECESSED,
ADJUSTABLE COMPARTMENTAL LIGHT FIXTURE HOUSING
(2) SOLAIS
#LR38/25/30/1200
21W. PAR 38 L.E.D.
0 41,
B3
CONTECH #RAN15038– X3– B -21LBL RECESSED,
ADJUSTABLE COMPARTMENTAL LIGHT FIXTURE HOUSING
(3) SOLAIS
#LR38/25/30/1200
21W. PAR 38 L.E.D.
;.k 4 c)
C
CON –TECH #RL38- 21LBL/ 6" RECESSED DOWN LIGHT
WITH 21 WATT LABEL. SPECULAR REFLECTOR & WHITE
TRIM
(1) SOLAIS
#LR38/25/30K/21W/
1275/GY 21W PAR38 LED
D
_
CONTECH #LT SERIES TRACK (SILVER) LEGNTH PER
PLAN. SUPPLY WITH ALL CONNECTORS AND END
FEEDS AS REQUIRED.
N/A
D2,4,6,8,12
E
SEASCAPE #THA016X9 BLACK AND WHITE CHECKER
"LAMPDHADE" PENDANT FIXTURE W/ WHITE BOTTOM
DIFFUSER & CANOPY W/ 3' CORD.
(1) TCP,
32 WATT CF SPRING
LAMP -28932
l
F
CON –TECH LIGHTING #CTL838 /2 –U PAR38 ADJUSTABLE
TRACK FIXTURE WITH BLACK FINISH.
(1) SOLAIS
#LR38/25/30K/21 W/
1275/GY 21W PAR38 LED
H4*
11 II
SIMKAR #CH232 –B11 –UNV 4' FLUORESCENT OPEN
STRIP LIGHT SUSPEND OR SURFACE MOUNT PER PLAN.
EL= PROVIDE EMERGENCY BATTERY PACK EM= CONNECT
TO NIGHT LIGHT CIRCUIT
(2) PHILIPS
F32T8 TL830 ALTO II
32 WATT T8
H8*
11 11
SIMKAR #CH2232 –B11 –UNV 8' FLUORESCENT OPEN
STRIP LIGHT SUSPEND OR SURFACE MOUNT PER PLAN.
EL= PROVIDE EMERGENCY BATTERY PACK EM= CONNECT
TO NIGHT LIGHT CIRCUIT
(4) HILIPS
32T8 TL830 ALTO II
32 WATT T8
K
SIMKAR #JBH- 2- 17 –B11 –UNV WALL MOUNTED
FLUORESCENT FIXTURE MOUNTED OVER LAVATORY
(2) 17W T8 -24
is
L8
CON –TECH LUX BEAM #LB122 SERIES SILVER TRACK
HOUSING BEAM (LEGNTH PER PLAN) WITH CON –TECH
LT SERIES TRACK SECTION OF MATCHING LENGTH.
SPECIFY CURRENT LIMITERS AS NEEDED PER CODE
'LB,4,6,8,12 '
X
-EN-
BEST LIGHTING #EZXTEU1RW –EM SURFACE MOUNTED
THERMOPLASTIC EXIT – WHITE WITH RED LETTERS
(LED INCLUDED)
X1
BEST LIGHTING #ELXTE– U- 1– RC –A –EM SURFACE
MOUNTED EDGE LIT EXIT SIGN WITH UNIVERSAL
MOUNTING CANOPY. (CLEAR PANEL – RED LETTERS)
3.2W. L.E.D.
(INCLUDED)
Y
BEST #R1 SURFACE MOUNTED EMERGENCY LIGHTING
UNIT WITH SEALED BATTERY BACK –UP
(LED INCLUDED)
)
#657 (OR EQUAL) RECESSED EXHAUST FAN.
SEE MECHANICAL DRAWINGS
N/A
�!�
NOTE: ALL FIXTURES MAY NOT BE USED ON ALL PROJECTS
MANUFACTURER TO PROVIDE PERMANENT PRE - PRINTED MAXIMUM RE– LAMPING LABEL PER LIGHTING FIXTURE
SCHEDULE
* PROVIDE ELECTRONIC NORMAL OTPUT INSTANT START BALLAST
PARTIAL ONE LINE DIAGRAM
EXIST. LANDLORD DISTRIBUTION SWITCHBOARD
120/208V, 3PH, 4W
L.L. SPACE
TENANT SPACE
REMOVE AND COMPLETELY
DISCONNECT EXIST. PANEL
AND RETURN TO
OWNER /TENANT FOR
STORAGE. (NOT USED IN
THIS PROJECT)
I(\M 1IF– RE –USE EXIST. METER IF
L_TJ FEASIBLE, OTHERWISE PROVIDE
1 NEW PER POWER CO. AND
``1 LANDLORD REQUIREMENT
E— EXIST. 200A, 3P DISC. SWITCH
I I WITH (3) 200A FUSES.
c� VERIFY)
F1
EXIST. 4 #4/0 CU., 1 #
BOND, 2-1/2"C. (FIELD VERIFY)
VIE FOR
COMPLIANCE H
NFPA70 - NEC
DEC 282011
City
of Walla
ILDING DIVISION
EXIST. 200A, 3P, MCB
L____J
PANEL "L"
(EXIST.)
ONE –LINE DIAGRAM NOTES:
1. THE ELECTRICAL CONTRACTOR SHALL FIELD VERIFY
ALL EXISTING CONDITIONS PRIOR TO BID.
2. PROVIDE ENGRAVED NAMEPLATES ON EACH
SERVICE, PANEL, TRANSFORMER, DISCONNECT
SWITCH, MOTOR STARTER, ETC.
3. PROVIDE LISTING OF ALL BREAKERS & LOADS,
CLEARLY TYPED AND PERMANENTLY ATTACHED
INSIDE THE DOOR OF EACH PANELBOARD.
4. ALL WORK IN LANDLORD'S DISTRIBUTION SECTION
SHALL BE PERFORMED BY LANDLORD'S
CONTRACTOR AT TENANT EXPENSE.
5. ALL CONDUCTORS SHALL BE COLOR CODED AS
REQUIRED BY TEANT CRITERIA MANUAL AND N.E.C.
6. TENANT'S EQUIPMENT IN THE MALL ELECTRIC ROOM
MUST BE CLEARLY IDENTIFIED WITH TENANT'S NAME
AND SPACE NUMBER.
•
:i
CURRENT
LIMITING
SUB –
PANEL
'CLS'
NUMBER OF
CONDUITS AS
REQUIRED.
TO TRACK
LIGHTING
LOADS
24/7 TIMECLOCK.
SEE LIGHTING CONTROL
DIAGRAM ON SHEET E2.
MIN. 6 FEET
WIRE LENGTH
RECEIVED
DEC 2 0 2011
PERMITCENTEF
NENGINEERING INC.
4115 N. 15TH AVE
PHOENIX, AZ 85015
(602) 265 -1559
PROJECT NO, 1 I 1 -23 1
zo 0
u
u 0oo Z+
•
C w
o
O fl-
J
LL
z
o_W
g0
Z
Q W
J
_I
• • • • •
00
00
na
— 00
c C
L
u
�I–r
c
r.
‘g- �.0
� o o �.
- EZ ' Gj
CU 0 V
Q) Q 00
� V) V'f
REVISIONS:
i
SEAL:
DATE:
12 -13 -11
DRAWN BY:
NPE
FILE NAME:
PH11- 095 -E3
PROJECT NUMBER:
PH 11 -095
w
2
rn
uJ