HomeMy WebLinkAboutPermit M11-015 - BATTELLE RESEARCHBATEI.I.F RESEARCH
12822 GATEWAY DR
Mi 1 -015
City 4lukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Inspection Request Line: 206 -431 -2451
Web site: http: //www.ci.tukwila.wa.us
MECHANICAL PERMIT
Parcel No.: 2716000050
Address: 12822 GATEWAY DR TUKW
Project Name: BATTELLE RESEARCH
Permit Number: M11 -015
Issue Date: 02/08/2011
Permit Expires On: 08/07/2011
Owner:
Name: RREEF AMERICA REIT II CORP/
Address: PO BOX 4900 #207 , SCOTTSDALE AZ 85261
Contact Person:
Name: JESSICA BRUCE
Address: 3602 S PINE ST , TACOMA WA 98409
Email: JESSICAB( ASEI.WS
Contractor:
Name: AIR SYSTEMS ENGINEERING INC
Address: 909 S 28 ST , TACOMA, WA 98409
Contractor License No: AIRSYE *229KN
Phone: 253 - 572 -9484
Phone: 206 628 -9484
Expiration Date: 02/01/2012
DESCRIPTION OF WORK:
INSTALL EXHAUST SYSTEM INCLUDING THREE EXHAUST FANS AND ONE ROOFTOP INTAKE
HOOD. INSTALL MAIN EXHAUST PLENUM DUCT WITH TWO FLEXIBLE HOSE EXHAUST DROPS.
INSTALL CONTROL DAMPERS FOR EF -1 & MAH -1
Value of Mechanical: $6,445.00 Fees Collected: $269.31
Type of Fire Protection: UNKNOWN International Mechanical Code Edition: 2009
Permit Center Authorized Signature:
Date:
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the
back of this permit.
Signature:
Print Name:
Date: ✓ �/ ° I
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
doc: IMC -4/10
M11 -015 Printed: 02 -08 -2011
• •
PERMIT CONDITIONS
Permit No. M11 -015
1: ** *BUILDING DEPARTMENT CONDITIONS * **
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
4: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
5: Manufacturers installation instructions shall be available on the job site at the time of inspection.
6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila
Building Department (206- 431 - 3670).
7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206- 431 - 3670).
8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
doc: IMC -4/10
M11 -015 Printed: 02 -08 -2011
CITY OF TUKWILA
Community Development Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.ci.tukwila.wa.us
Mechanical Permit No.
Project No.
MECHANICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *please print **
SITE LOCATION
ff C� ,/p King Co Assessor's Tax No.: R ! 1 190 6 60
Site Address: 1 u 2 Re-5 . L Q(1 V 1,
Tenant Name: eC� �t f e-5 di
Property Owners Name: R.r F �-[/1 u[ � L� /w--t I 11 CD
Mailing Address: P 4166 �� # •-61
Suite Number:
New Tenant:
Floor:
❑ Yes ..No
/4 2, 2. is, I
City
State Zip
CONTACT PERSON - who do we contact when your permit is ready to be issued
Name: e-G4 L - 0 (,(f4
Mailing Address: '3 Lsio,A 5 ` T" U fie_ St
E -Mail Address: X551 C1i,b( e..061 - W5
Day Telephone: d5."3 -
Ta.c00 ma. WA 4 -Oq
City t="5---g t'g
Fax Number:
MECHANICAL CONTRACTOR INFORMATION
Company Name: Air 6 n 6 t( �1 L,) g-�-,� r
Mailing ddress: ✓ e . Y [ 'Ile, ✓ ✓✓ 1 aLiti W f1
g mGl,
Contact Person: j ( 1 4 L / ��F&V' L^1 , , l
E -Mail Address:��6 � t ll d4 . 1.0
Contractor Registration Number: ill 5 Y a (7,q f
City State
Day Telephone: 7
Fax Number: (. 5 -3 - 77
Expiration Date: tR "" 1 - 1
(9
ARCHITECT OF RECORD All plans must be stamped by architect of record
Company Name:
Mailing Address:
Contact Person:
- E -Mail Address:
City
Day Telephone:
Fax Number:
State
Zip
ENGIN
ROF.
COR
-A
Pi
ans;
be stamped by engine
eco
Company Name:
Pi-if ap -1 -0 r I 1 d ' )e)(_44L
- Mailin Address: '3 W ° (. om 5-F z.6 (dL. Log, . c(g `Cvq
City S to ZipQ"
Contact Person: [6 -6- r (.C. Day Telephone: ! -(4 7Jj
• cJ ��rff KJ � �-�l • Lug F �
E-Mail Address: J� � � Fax Number: ���
H:Wpplications\Ponns- Applications On Line \2010 Applications \7-2010 - Mechanical Permit Application.doc
Revised: 7 -2010
bh
Page 1 oft
Valuation of project (contractor's bid price): $ (s) -7��`TJ,, 9 '^ / , t /
Scope of work (please provide detailed information): 1.06 k .J� / '(L_k6 f 51 7` , = j ()LI LIL d S
•ThSitut metuti e}c 1n v- l e r) u rr, cle.ikLbLe,
d4f6 5, ►' 61 e.( (EF -(' nn 4E4 -1,
Use: Residential: New ❑ Replacement ❑
Commercial: New Replacement ❑
Fuel Type: Electric
Gas ❑ Other:
Indicate type of mechanical work being installed and the quantity below:
Unit Type;
Qty
Unit Type: ;
Qty
Unit Type:
Qty
Bioler /Compressor
0 -3 hp /100,000 btu
Qty
furnace <100k btu
air handling unit
>10,000 cfm
fire damper
furnace >100k btu
evaporator cooler
diffuser
3 -15 hp /500,000 btu
floor furnace
ventilation fan connected
to single duct
thermostat
15 -30 hp /1,000,000
btu
suspended/wall /floor
mounted heater
ventilation system
'
wood/gas stove
b0 50 hp /1,750,000
btu
appliance vent
hood and duct
emergency
generator
50+ hp /1,750,000 btu
repair or addition to
heat /refrig/cooling system
Incinerator — domestic
other mechanical
equipment
air handling unit <10,000
cfm
incinerator — comm/ind
PERMIT APPLICATION NOTE
Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the permit center to comply with current fee schedules.
Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing
and justifiable cause demonstrated. Section 105.3.2 international building code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING WNER O A THO ED AGELT:
Signature: Date: F r 1 1
Print Name: ae_ 41 Lat. l 1LL
Mailing Address:
als?-v• » Pme,
Day Telephone: v� ' i. 4 Z7 q
-r ma 1.01 1 Q 1(..e<4
City
State Zip
Date Application Accepted: �� ` 1
Date Application Expires: B
-
Staff Initials: ('N_
H:1Applications\Fonns- Applications On Line \2010 Applications17 2010 - Mechanical Permit Application.doc
Revised: 7 -2010
bh
Page 2 of 2
. •
wqs City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 - 431 -3665
Web site: http: //www.ci.tukwila.wa.us
Parcel No.: 2716000050
Address: 12822 GATEWAY DR TUKW
Suite No:
Applicant: BATTELLE RESEARCH
RECEIPT
Permit Number: M11 -015
Status: PENDING
Applied Date: 02/01/2011
Issue Date:
Receipt No.: R11 -00186
Payment Amount: $269.31
Initials: WER Payment Date: 02/01/2011 11:08 AM
User ID: 1655 Balance: $0.00
Payee: SANDRA COLVER
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Credit Crd VISA
Authorization No. 013169
ACCOUNT ITEM LIST:
Description
269.31
Account Code Current Pmts
MECHANICAL - NONRES
PLAN CHECK - NONRES
000.322.102.00.00 215.45
000.345.830 53.86
Total: $269.31
doc: Receiot -06 Printed: 02 -01 -2011
•
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWI.LA BUILDING DIVISION �' ...
6300 Southcenter Blvd:, #100, Tukwila: WA 98188 (206) 431 =3670
Permit Inspection Request Line (206) 431 -2451
mu oi$
ojec�t: { (�n a
t1 `42 Js t
Type of nspection.
ACOMMENTS:.r ,_ .. Z CoANtIA,U 6441S -
Ad ress ,,y,�
Daye�C Ilgd
/, S AA d
4CG
Special Instructions: I .
,.. 04 iQ9��
e ,ls v , & - 2
Date Wanted
.� f
w t ! -'—„,2
m.
Reque ter: f
6!
It M _ -t! `' dil_ fto a & iiv 114 .4 tiot-
ph
//
- �Vrrnit Corn 0 1-f, m (J
Approved per applicable codes. CorrectionS-required prior to approval. -
ACOMMENTS:.r ,_ .. Z CoANtIA,U 6441S -
7 c e a - I1 +ilii t p(en tai obi'
OU - %4)l2- 6-40 iL t`Q f 9 •�,S r i"'_ gip:
6/1.!' A 1 -,Q )4--1-t ` /- Af -- "J„ -4' ,44,44---7: j
,pp,R4r
x Ec (✓ 31O er
i 4_ p to t1 dpi cakes F-i
P
44 1, i ��n ///��� %%% t /p�/� �! �(+ �%k�
r (A 4 I t a LYE+ • w t -.� \ c i t 44.Q+�8 ).0
r_AiteA • •
It M _ -t! `' dil_ fto a & iiv 114 .4 tiot-
10 n.40A tif/+-� .1- A724. -
//
- �Vrrnit Corn 0 1-f, m (J
❑ REINSPECTION FEE REQUIRED. Prior to next inspection; fee must be
paid at 6300 Southcenter Blvd:, Suite 100. Call to schedule reinspection.
•
sr;
fdt
FILE COPY
CarbcP11371Mae-f001-SMIWPM Gas Detection System
DESCRIPTION
Wall- mounted gas monitor with built -in carbon monoxide (CO) sensor,
accepts one analog remote device such as a secondary gas sensor,
temperature or humidity sensor.
APPLICATION
To detect and control levels of carbon monoxide (CO) and other gases in a
wide variety of commercial and industrial applications such as Carbon
Monoxide level in parking structures, engine repair shops, equipment rooms
and ventilation systems, etc. The controller can communicate with any
compatible electronic analog control, DDC /PLC control or automation
system via binary and /or analog output signal.
FEATURES
• Continuous monitoring
• One (1) built -in CO electrochemical
sensor
• Easy plug -in sensor
• One (1) remote analog input,
4 -20 mA
• One (1) digital input
• Two (2) relay outputs:
- Four stage control
- Fail -safe assignable
• One (1) analog output,
(0)4 -20 mA / (0)2 -10 VDC
- Selectable for low, high, or averaging
• One (1) 24 VDC switched output
• Liquid Crystal Display (LCD)
SPECIFICATIONS
• LED status indicators
• Accepts toxic or combustible
gas, refrigerant, temperature T
or humidity temperature .��
remote sensor inptjt REVIE ED Rrformance Tested & Certified
• Built -in horn
• Keypad user interf
• Simple menu -drive
programming
• Modular technolog
C O N T R O L S
PolyGard
SPC3 -1112
CE
City of Los Angeles Approved
CObE CO�IPLLANG n UL 2075STD
APPRnvED
FEB 07 1U11
• Overload & short- cfrcuit
protected
• NEMA 12 enclosur
• Easy maintenance
Electric
Power Supply
Power Consumption
Sensor Performance
Gas detected
Sensor element
Range
Stability & Resolution
Repeatability
Long term ouput drift
Response time
Sensor life expectancy
Sensor coverage
Installation Location
Mounting height
City of Tukwila
BUILDING DIVISION
RECEIVED
FEB 012011
r t,
TCEMR
Type of Control
24 VACNDC, - 20 %/ +15% General
50/60 Hz,
reverse polarity protected
5 VA (0.2 A) w/ (1) remote sensor
connected
Carbon monoxide (CO)
Electrochemical, diffusion
Span field adjustable
from 0 -200 to 0 -300 ppm
via calibration,
0 -250 ppm factory set
± 3.0 ppm of reading
± 3.0 % of reading
< 0.4% signal loss /month
tso < 50 sec.
3 -5 years, normal operating
environment
5,000 sq. ft., max 10,000 sq. ft.
(465 m2, max 930 m2),
under "ideal conditions"
5 to 6 ft. (1.5 -1.8 m) above floor
Analog input
Analog reading
Stage level / setpoint
- hysteresis/
switching differential
Digital input
- application
Four -stage (S1 to S4) control,
assignable up to two (2) binary/
relay, horn /audible alarm, and
24 VDC / 50 mA switched
outputs, i.e. low -high stage for
relay output, horn / audible alarm
and switched 24 VDC at any
stage for remote alarming
One (1) 4 -20 rA, for additional
remote sensor, , load < 55 mA /
200 Q, reverse polarity protected
Current and mean (average)
value
Field adjustable over full range,
four (4) stages (S1 to S4) per
analog input, assignable to
current or mean (average) value
Selectable for each sensor point
One (1); can be assigned to any
relay (R1, R2).
Remote audio /visual alarm reset
or override function
Customer Services (858) 578 -7887 & (888) GO INTEC Fax (858) 578 -4633 & (888) FX INTEC
INTEC Wilson Mohr, 9730 Distribution Ave., San Diego, CA 92121 www.inteccontrols.com
Specification subject to change without notice.
Page 1 of 5 Printed in USA 100511
1 ,GREENHECK
Building Value in Air.
FILE COPY
Printed Date: 1/20/2011
Job: Battelle
Product Type: Fan
Mark: SE
28
°SE1
24.25
AirFlow
Note. Wall Housing Sizes 42 and Larger with heavy motors and all
Filtered Wag Housings need additional bracing.
NOTES: All dimensions shown are in units of inches
Fan weight is without accessories
DIMENSIONS
Approx. Fan
Weight (lb)
Recommended
Roof/Wall Opening: (in)
35
25.25 x 25.25
PERFORMANCE (Elevation ft = 1,243, Airstream Temperature F =
Sidewall Direct Drive Exhaust Fan
Tag SE
STANDARD CONSTRUCTION FEATURES
• Fan panels of galvanized steel • Aluminum blade propeller • Die formed,
galvanized steel drive frame assembly • Corrosion resistant fasteners
SELECTED OPTIONS & ACCESSORIES
Aluminum Propeller
Class B Motor Insulation or Greater
UL/cUL -705 - "Power Ventilators"
Motor w/ Thermal Overloads
Wall Housing - Kit w/ OSHA Guard
Galt'. Weatherhood 45 Degree w/ B.S.
REVIEWED FOR
CODE COMPLIANCE
ApDonVED
FEB 07 2011
City of Tukwila
BUILDING DIVISION
Qty
Model
Volume
(CFM)
SP (in
wg)
FRP
M
Operating
Power
(hp)
Motor
Information
Size (hp)
V /C /P
Encl:
Motor RPM:
Windings
1
SE1- 18- 429 -B4
2,369
0.25
1,160
0.24
1/4
115/60/1
ODP
1160
1
Static Pressure (in wg)
1.0
0.8
0.6
0.4
0.2
0.0
LwA - A weighted sound power level, based on ANSI S1.4.
Sones calculated using AMCA 301 at 5.0 ft.
dBA - A weighted sound pressure level, based on 11.5 dB
attenuation per octave band at 5.0 ft.
dBA levels are not licensed by AMCA International.
0.5
i
W¢
0
5
RPM Curve
' 'System Curve
Brake Power Curve
Do not select to the left of this surge curve
CAPS 4.5.1251
10
15
20
Volume (CFM) x 100
25
30
P: \Matt \wincaps \Jobs \Battelle.gcj
1
35
0.4
0.3
0.2
0.1
0.0
ke Power (hp)
amca
amino
EMI!
1OYnD
AIR
nln
MID cony nmot
nttocmnon
InitnafTlOOnt. Inc.
ECEIvED
FEB 01 2E1
CENTEF
,
Page 1 of 8
niet Sound Power by Octave Band
Lwa
dBA
Sones
62.5
125
250
500
1000
2000
4000
8000
78
70
69
67
67
65
61
52
71
60
10.1
Static Pressure (in wg)
1.0
0.8
0.6
0.4
0.2
0.0
LwA - A weighted sound power level, based on ANSI S1.4.
Sones calculated using AMCA 301 at 5.0 ft.
dBA - A weighted sound pressure level, based on 11.5 dB
attenuation per octave band at 5.0 ft.
dBA levels are not licensed by AMCA International.
0.5
i
W¢
0
5
RPM Curve
' 'System Curve
Brake Power Curve
Do not select to the left of this surge curve
CAPS 4.5.1251
10
15
20
Volume (CFM) x 100
25
30
P: \Matt \wincaps \Jobs \Battelle.gcj
1
35
0.4
0.3
0.2
0.1
0.0
ke Power (hp)
amca
amino
EMI!
1OYnD
AIR
nln
MID cony nmot
nttocmnon
InitnafTlOOnt. Inc.
ECEIvED
FEB 01 2E1
CENTEF
,
Page 1 of 8
e RVF SERIES
EXTERIOR -MOUNT EXHAUST FANS
DIMENSIONAL DATA
1 MI"
A
• -D
model A' B C
B
D
E
RVF 4 4 101/4 13 6 23/4
RVF 4xL 4 101/4 13 6 23/4
RVF 6 6 101/4 13 6.._..........23 /4
RVF 6x1. 6 141/4...._.. 17 6 23/4
RVFBxt 8 141/4 17 .... 6 23/4
All dimensions in inches.
`Duct connection is 1 /s" smaller than duct size.
PERFORMANCE DATA
FIVE
YEAR
WARRANTY
VI�
CERTIFIED
C UL US
SP.
VUS
MOM
lank la the Energy
Star Rated Models
in Pafoenerce
Data Dart
2.
1.4
1.
;
too
y 0.80
0.60
0.90
0 20
0m
AIR PERFORMANCE GRAPHS
0
ihibt
Es
Nem
■
mai
WM
son
IN
NM
mei
MI
IIII
MIL
100
150
200 250 300
Row Rate MR 4)
350
400
450
Fan Energy Rated Max. : +' ; St agc Pre ssyreiitflnchts.Vd4; .. Max. Duct ,t _:�'4 :`;
Model Star RFM Volts Watts Wattage Range Amps 0 Or 0.2" 0.4" 0.6" 0.8" 1.0" 1.5" Ps Dia.
RVF 4 ✓ 3060 115 19 15 –19 0.17 134 120 112 83 37
"----- RVF4XL — 2700 115 92 73 – 92 0.84 193 180 172 154 136 118 91 — 0.78" 4"
RVF6 — 2550 115 92 78 – 93 0.84 242 220 204 177 150 123 68 _— 1.27" 4"
RVF6XL — 3000 115 149 145 – 157 1.46 381 360 346 315 285 258 213 64 1.74" 6"
RVFBXI — 2900 115 151 140 – 155 1.42 435 410 392 348 312 282 235 102 1.82" 8"
RVF Series performance is shown with ducted inlet. Per HVF's Certified Ratings Program, charted air flow performance has been derated by a factor based on actual test results and
the certified rate at .1 inches WG.
500
RECEIVE
FEB 0 1 2011
PERIITCENTER
• °
FantechUnited States 1712 Northgate Blvd. • Sarasota, FL. 34234 • 1.800.747.1762 • www.fantech.net Item J: 450483
Canada 50 Kanalflakt Way • Bouctouche. NB E4S 3M5 • 1.800.565.3548 • www.fantech.ca Rev Date: 082208
Fantech, reserves the right to modify, at any time and without notice, any or all of its products' features, designs, components and specifications to maintain their technological leadership position.
Tay: 6F-3
_
meamommosammewriaissamandes
Direct Drive Pressure Blower,
With Foot Mount Base
Series D -FMB, 0.5 HP - 3 HP
TECHNICAL.
INFORMATION
PROJECT:
LOCATION:
ARCHITECT
ENGINEER:
SALES ENGINEER
DATE:
www.monoxivent.com info@monoxivent.com
309 -794 -1000
Blower Is constructed of cast aluminum (both housing and wheel)
Wheel is radial blade type
TEFC motors are standard
UL, CSA approved
Motor is 3450 RPM
Blower may be rotated (360 degrees) in 90 degree increments, allowing discharge
orientation to meet requirements
Provided with clockwise rotation only
uoun._ a_. •_ - -. _.._.
08/230 VoT)
ase: 208/230/460 Volt"
1- Phase: 1
Single ibmg
base ase CFM c Static Pressure DBA Motor
ode/ Model ae RPM r 2" 3" 4" 5" 6" 7" at 5' Frame
X05- 005 -3 0.5 3450 450 435 390 350 260 150 -- 85 56
D1r -1 010 -3 1.0 3450 -- -- -- 770 665 540 320 -- 83 56
D15- 015 -3 1.5 3450 965 910 840 780 675 550 330 - -- - -- 83 56
D20 -1 020 -3 2.0 3450 - -- -- 1237 1140 1070 990 915 825 735 86 145T
030 -1 030 -3 3.0 3450 1490 1420 1275 1213 1140 1070 990 915 825 86 145T
Single Phase: 115/230 Volts; Three Phase: 208/230/460 Volts 10.5" Wheel: D05; 12" Wheel: D10, D15; 13.5" Wheel: D20, D30
-= Unstable operating range
0 Series Dimensions
Model Wheel Dia. Jnlet Dia. Outlet Dia A B Q Ja E a H. I ,J 6
005 10.75 5 4 9.25 6.5 7.5 7.5 6.25 5.13 12.25 3.25 5 4 11.5
C 10 ) 11.63 7
D15 11.63 7
D20 13.5 7
D30 13.5 7
6 12 7.5 10 9 8 5.13 12.25 3.25 7 6 13.25
6 12 7.5 10 9 8 5.13 12.25 3.25 7 8 13.25
6 12 7.5 10 9 8 5.13 12.25 3.25 7 6 14
6 12 7.5 10 9 8 5.13 12.25 3.25 7 6 14
RECEIVED
FEB 011Q - io
TCFATER
arm ho x cavity 1
Mode F'GI
A
7/8
Throat Width
Curb Cap Width
Qimensio al
Optional ;
Damper
Width x
Length
;Throat: Throat
Area Width x
Length
Curb Cap
Width x
Length
All dimensions
shown in inches
Throat Length
Curb Cap Length
Hs- 11/2
ti 0 030 0.047 0.07 0.089 0.119 0.-149 0.196 " a 11 1
NON DUCT60 STATIC PRESSURE DROP (IN, VViy p .21
mi 0.053 , 0.085 0.127 ! 0.158 0.212 0.267 ; 0.350 . •a m s
(Fr /MIN) ..........1 ..........:..
527/1065604/1220
4262 4880
5328 6100 }
6393 7320 • 7459 _8539 ;
8524` 9759
9590 19979..'
10655 ; : 12199..
11721 „13419
' !! ; 12786 14639
HOOD INTAKE VELOCITY../ THROAT VELOCITY
235/475 297/600 ; 364/735 406/820 , 4.70/950
yiu
4.00• 24' x 24.1..48 x 30 24„x24, 52 39 19 . 5 , 1899 2405 2939 3279 3798
5;00 24.x•30, ;, 30_ 36, 24 x 30 ; 49 51 1.9 ; 5 . 2374 3005 „,3874 4998 4747
6 00 24. x 36
1!.k41.5 x 42, 24.x 36 47, 63',19 I • 5 ' •2848 , ' , 3607. I 4.469.,;,11 4998 + • 5897_
700 _' 24 x 42 ; 30 x 48 24 x 42 54 , 63 , 19 . 5 i 3329 I 4208 5144., 5738 6646
• 8 00 : 24 x 48 30 x 54... 24 x 48 ` 52 '. 75 ' 19 5 I,,. 3798 ' 4809 , 5679 6557 - 7596m,
9.00 24x54_•, 30.x60 24x54 : 50 ,87 19 ; 5 • 4272 5411 6614 7377 8545
1.0 00 ; 24 x 60 .30 x 66 24 x60' 55 ' :87 • 19 • 5 4747 6012 7349. .8196. . 9494._
11..00 : 24 x 66. ! 30 x 72....ri 24x 66 54:99 : 19 5 5222 : I 6613 8093 I • 9016 10444
112.00 24x 72 30 x78 24 x 72 58. l 99 19 5 5697 7214. 8818 9836 ,, 11393
..13.00 24x 78 [ 30X:84 .., 24 x78 56 111 19 5 6171 7815... 9553 10655 ! 12343
14.00 24 x 84 , 30 x 90 24x84 : 60 ..111 ! 19.... 5 6646 8417, 10288 11.475• • 13292
15.00 24x 90 .30: x 96 .' 24;x;90 58 `.123 19 • 5 . 7121 9018. : 11023 12295 ' 14242
. •6.25 ' 30x 30 1 36 x 36... 30x 30 60; 51 ; 19 • 5 2967 3757 4593 5123 5934..
. 7.50 30 x 36 :36 x 42 30 x 36 58 63 19 5 3560 . 4509 5511 . 6147 7121
8.75 • 30 x 42 36 x 48 30 x 42 • 57 75 : 19 5 4154 5260 6430 ; 7172 8308
10.00 30 x 48 1 36 x 54 30 x 48 64 75 19 5 4747 ! 6012_._ 7349 8196 9494
11.25 30x 54 ,.; 36 x 60.., 30 x54 62 .. 87 : 19 5 5341 6763 8267 ' 9221 10681
•
12.50 30 x 60 ; _36 x 66 I 30 x 60 ' 60 99 19 5 5934 7515 i 9186 10246 11868
,13.75; 30 x66 : 36 x 72 I 30 x 66 66 • 99 ;19 5 ; 6527 : 8266 10104 11270 j 13055
........ 71 _._. 11023 12295 , 14242
15.00 30 x 72 36 x 78 30 x 72 64 i. 111 • 19 5 21 9018
.25 ! 30 x78 36 x84 7714 9 629 11941 1 13319 15428
17.50 30 x 84....36 x 90 30 x 78 . 67 123: 19 5 7
__. .... 7 4
8__. 10. 1 12860 14344 16615
18 75 30 x 90 • 36 x 96 , 30 x 90 ! 72 ; 123: 19 • 5 8901 . 11272 13779 15368 17802
9:.00: 36 x 36 42 x 42....:;. 36 x36 .... 69. ; 63 ; 19: 5 • 4272........ :5411 661:4;. 1•• 7377 ,18545
10:50.•;• 36.x 42 42 x 48 36 x 42, 67 : 75 19 5 4985 6312 :.: 7716 9606•:;,;;; 9969 •
• 12.00. 36 x 48; 42 x 54 ,1 36x 49 ; 66 87 : 19 5 5697 : 7214,.,. 8818 9836 11393
.
13.50 30x 54 42 x 60 ; 36 x 54 73 87 19 • 5 6409 :1 8116 ; 9921 11065 12817
15.00 36 x 60 t 42 x 66 ; 36 x 60 72 ! 99: ; 19 5 7121 9018. 11023 12295 14242
. 16.50 36 x 66 : 42 x 72 36 x 66 78 ' 99 19 . 5 7833 9930. .1._ 12125 13524 15666
18.00 36x72..,: 42x 78 36 x 72 76' 111; 19•5 8545 : 10821,. 13227 14754 17090
• 19.56; 36x 78 x42 x 84 ; 36 x 78 74 123 - .19 5 9257 11723 14330 15983 ; 18514
22.50 36 x 90 421x 96 36 x 90 78 135::••19., 5 10681 i 13527 16534 184 , 29332
21.00 : 36 x 84 42 x90 36 x 84 80 123 19.;! 5 9969 12625 15432 17213 42
4 "21362,
• 24.00 36 x 96 42x 102. q§)...5....94. • 83 ? 135 , 1:9 ' 5 ; ,.11393, 1 14428.. 17637 , : 19672 • 22787
25.50: 36 x10? i 42 x 108 ::.36 x 102 81 A47 19 • 5 12105 15330 18739 20901 24211 .
12.25 42. x 42 .48 x 48. 42 x 42 78 75 .;. 23 : 5 ' 5815 ' 7365 ; 9002 10.041 11631
• 14.00 42 x 48 48 x 54. 42 x 48 76.87: 23 • : 5 • • 6646 8417 10288 11475 13292
• 15.75 ,, 42 x.54. 48 x.60 42,x 54. 85 87 , 23 5 7477 9469 . 11574 12909 14954
17.50 42 x 60. !48 x 66. 42 x 60 83 99 ; 23 , 5 r 8308 10521 ; 12860 • 14344 16615
19.25 42. x 66 48 x 72 42 x66 : 81 :111 • 23 ; 5 i 9138 11573 14146 , 15778 • ,..18277
: 21.00 ; 42. x 72 48 x 78__. 42 x 72 88 :111 ' 23 ! 5 9969 . 12625 15432 17213 19938
. 22.75 • 42. x 78 : 48 x 84 42 x 78 86 1 1231.23 : 5 10800 13677 16718 ' 18647 21600
24.50: 42 x 84. 48 x 90 . ` 42 x 84 84 1135;i; 23 5 . 11631 147.2.9....j. 18004 20081 23261
26.25 ' 42. x 90 :.48x•96•• , 42 x_90 90 i 1351 23 5 :.12461 . 15781 , 19290 • 21516 24923
28.00 42.x 96 : 492c 102., 42 x.96 , 88 ;147 ; 23 5 13292 16833 20576 22950 1 26584
29.75 42 x 102 48x 108 42 x 102 93 :147: 23 .5 14123 17885 21862 • 24385 1 28246
31.50 42 x 108 48 x 114 42 x 108 91 .159 23 5 14954 18937 23148 25819 29907
16.00. 48 x 48 54.x 54 ' 49:x 48. 86 • 87. 25. 5.... 7596 9619 11758 13114 . 15.191,.
18 :00 48 x 54 54 x 60 48 x 54 •
85 99 , 25 5 8545 10821 13227 14754 1.709D
20.00 48 x60 54 x 66 48,x.60 94 99:25 5 .. 9494 12024. 14697 16993 18989
. 22.00 48 x 66 54 x 72. 48x66 92. 111 25 5 . 10444 - 13226 16167 18032 20888
24.00 .48 x 72 . 54..x• 78:.. 48 x 72 90..123. 25 : 5 .:.11393 14428 17637 19672 22787
26.00 48 x.78 54 x 84 48 x 78 98 " 123 ' 25 5 12343 15631 19106 21311 24685
28.00 48 x 84 54 x 90 48 x•84 92 ;135 25 5 13292 16833 20576 22950 26584
30.00 48x 90•. " 54 x 96.....;:48:x90 s .98".:135. 25 5 14242 18036 22046 24589 28483.
32.00 • .48 x.96.: 54 x 102 - 48 x;96 96 147... 25 5 15191 19238. 23515 26229 30382.
34.00 48 x 102: 54 x 108.•••••;;48.,x 102 94 1591 25 . 5 16140 20440 24985 27868 32281
36.00 • 48 x 108 54 x 114 48 x 108 100 159' 25 . 5 17090 21643 26455 29507 34180
38.00 48 x 114 54 x 120. 48.x 114 98 171 25 5 18039 22845 27924 31147 36079
0
<1
POUNDS
Yes i 82 ,.
Yes 91
• Yes,_!
Yes . 163
Yes 174
Yes ; 185"
,13852 15859 Yes „!,
14917 17079.. Yes 230. rvl
15983. . 18299.
• 6659 : 7625.. • Yes 108
.7991 • 9149 Yes 119_.
_ 9323 10674 Yes
„10655_ • 12199 Yes , 43 , 1
11987., 13724 , Yes 174
13319 15249 Yes ; 186,
14651 16774 Yes 1 200
15983 I 18299 Yes 225
17314 19824 Yes ; 251
18646.,_,. 21349 Yes ' _ 264
;.. 19978 22874 Yes 278!
9590 1,Q979.. Yes : •
.11188 12809.... Yes ' 141_..
:12786 ` 14639! Yes.1_ •176.
14384! 16469 Yes,' 198,_...,
y 15983 18299:_:. Yes 208, !
17581 20129 Yes 214.•
19179 :: 21959 Yes_! 252
20777 23789. " Yes _j. 280. •
22376 r 25618 "1 •Yes, 295
23974 27448•_; Yee 311
'2,5512 29278 Yes ; 324
,27170,..,,, 31108 .! No 340
13052 14944. Yes 178.
14917 17079 Yes 221
16782 ` 19214 1 Yes ! 252
18646 21349 Yes 261
20511 23484 i Yes ' 291
.22376 25618,•, Yes ' 320
24240 •._.27753 Yes 355
26105 29888 Yes___ 373._.
27970 32023 Yes E 392
29834 34158, No.. , 412_
31699 36293 No 429
33563 38428 : No 450
17048 19.519 Yes. 257
1.9179: ;21959 • Yes.•: .278
21310 24399 ,Yes ;299
23441 26838 Yes.I 832....
25572 ..29278 Ye,.� 353
277,03 . 31718 .:... •N,.0<... 383.
.. :298.34.: 341:58; ' NQ 441:2
31965
34096
36227 41478 . j No rip
• 38358
40489 2O 4 `1Vb X117
PERMIT CENTER 9
06 -30 -2011
City of Tukwila
Jim Haggerton, Mayor
Department of Community Development Jack Pace, Director
JESSICA BRUCE
3602 S PINE ST
TACOMA WA 98409
RE: Permit No. M11 -015
12822 GATEWAY DR TUKW
Dear Permit Holder:
In reviewing our current records, the above noted permit has not received a final inspection by the City of
Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform
Plumbing Code and /or the National Electric Code, every permit issued by the Building Division under the
provisions of these codes shall expire by limitation and become null and void if the building or work authorized
by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work
authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180
days. Your permit will expire on 08/15/2011.
Based on the above, you are hereby advised to:
1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final
inspection. Each inspection creates a new 180 day period, , provided the inspection shows progress.
-or-
2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is
due to expire. Address your extension request to the Building Official and state your reason(s) for
the need to extend your permit.
The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is
determined that your extension request is granted, you will be notified by mail.
In the event you do not call for an inspection and/or receive an extension prior to 08/15/2011, your permit will
become null and void and any further work on the project will require a new permit and associated fees.
Thank you for your cooperation in this matter.
Sincerely,
'IA ---'81
Bill Rambo
Permit Technician
File: Permit File No. M11-015
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665
• N �1 •
PE
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: M11 -015
PROJECT NAME: BATTELLE RESEARCH
SITE ADDRESS: 12822 GATEWAY DR
X Original Plan Submittal Response to Incomplete Letter #
DATE: 02 -01 -11
Response to Correction Letter #
Revision # After Permit Issued
DEPARTMENTS:
1
building Division
Public Works
,4w\ N%
Fire Prevention
Structural
n
Planning Division
Permit Coordinator
Ilk
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
DUE DATE: 02 -03 -11
Complete '711 Incomplete ❑ Not Applicable ❑
Comments:
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES/THURS ROUTING:
Please Route 7 Structural Review Required ❑ No further Review Required ❑
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS:
Approved
Notation:
Approved with Conditions
DUE DATE: 03 -03 -11
Not Approved (attach comments) ❑
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents/routing slip.doc
2 -28 -02
Contractors or Tradespeople Prater Friendly Page
•
General /Specialty Contractor
A business registered as a construction contractor with L &I to perform construction work within the scope of
its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Business and Licensing Information
Name AIR SYSTEMS ENGINEERING INC UBI No. 600099211
Phone 2535729484 Status Active
Address 3602 5 Pine St License No. AIRSYE'229KN
Suite /Apt. License Type Construction Contractor
City Tacoma Effective Date 5/15/1978
State WA Expiration Date 2/1/2012
Zip 984098197 Suspend Date
County Pierce Specialty 1 General
Business Type Corporation Specialty 2 Unused
Parent Company
Business Owner Information
Name
Role
Effective Date
Expiration Date
CRAWFORD, KANDI K
President
01/07/2010
Bond Amount
COLYER, SANDRA K
Secretary
01/07/2010
08358752
GEORGE, WILLIAM
Vice President
01/27/2010
CRAWFORD, DOUGLAS D
Vice President
01/07/2010
VIGILANT INS CO
ANDERSON, CURTIS M
02/01/2008
01/01/1980
01/07/2010
ANDERSON, LORINE
$12,000.00
01/01/1980
01/07/2010
Bond Information
Page 1 of 2
Bond
Bond Company Name
Bond Account Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Bond Amount
Received Date
8
FIDELITY & DEPOSIT
CO OF MD
08358752
02/01/2010
Until Cancelled
$12,000.00
01/27/2010
7
VIGILANT INS CO
82138376
02/01/2008
Until Cancelled
$12,000.00
02/04/2008
6
TRAVELERS CAS &
SURETY CO
081510353581BCN
02/01/2002
02/01/2008
$12,000.0001/15
/2002
Assignment of Savings Information No records found for the previous 6 year period
Insurance Information
Insurance
Company Name
Policy Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Amount
Received Date
30
LEXINGTON I INS
014180670
11/01/2010
11/01/2011
$2,000,000.00
10/25/2010
28
LEXINGTON INS
CO
049159165
11/01/2009
11/01/2010
$2,000,000.00
11 /02/2009
27
CO LEXINGTON INS
004052434
11/01/2008
11/01/2009
$2,000,000.00
11/06/2008
26
ACE AMERICAN
INS CO
HDOG23734941
11/01/2007
11/01/2009
$2,000,000.00
10/15/2008
25
CONTINENTAL
CASUALTY CO
2048527545
02/01/2007
02/01/2008
$1,000,000.00
01/16/2007
24
TRANSPORTATION
INS CO
TCP2048527545
02/01/2004
02/01/2008
$1,000,000.00
01/10/2007
Summons /Complaint Information
Cause
County
Complaint
Judgment
Status
Payment
Paid By
07 -2- 06730 -8
PIERCE
Date: 07/16/2007
https://fortress.wa.gov/lni/bbip/Print.aspx
Date:
Open
Date:
02/08/2011
Contractors or Tradespeople Poter Friendly Page
HRISTOPHER E WALLIS
nterPlead: No
Warrant Information
Education Information
Amount: $0.00
Amount: $0.00
0
Amount:
Page 2 of 2
https: // fortress .wa.gov /lni/bbip/Print.aspx 02/08/2011
EF -2 TO RUN
CONTINUOUSLY.
SHEET METAL SCREW
I" x 24 GA. GALV. SHEET METAL STRAP;
SECURE UNIT TO CURB AT EACH CORNER
WOOD SCREW INTO GURB NAILER
METAL FLASHING BY ASEI
RUN ROOFING TO
TOP OF CURB
GASKET BY A5E1
CURB NAILER.
INSULATION ALL AROUND
CURB, MAX. THICKNESS
TO MATCH CURB NAILER
GANT BY OTHERS
Rooftop II VAC
Not to Scale
nit
FACTORY ROOF CURB BY ASEI
LEVEL BASE
nstcllctio
De�ai
Fan Schedule
I.D. No.
Area Served
Mfr.
Model
Type
CFM
S.P.
RPM
Sones
Voltage
Ph.
HP or W
Op. Wt.
BDD
Controlled By
Notes
EF -1
Testing Area
Greenheck
SE1
Side wall direct drive
2,350
0.25"
1160
10.1
115
1
1/4 HP
35 lbs.
MD -1
CO Sensor
EF -2
Testing Area
Fantech
RVF 4XL
Exterior mount
180
0.1"
2700
N/A
115
1
92 W
20 lbs.
None
Continuous operation
EF -3
Testing Area
Monoxivent
D10
Centrifugal Blower
700
4.5"
3450
N/A
115
1
1 HP
100 lbs.
Internal
Wall Switch
Control Damper Schedule
I.D. No.
Mfr.
Model
Type
Damper Leakage
Actuator
Size
Quantity
Mfr. & Model
Voltage
MD -1
Greenheck
VCD -23
Low Leakage Control Damper
3 CFM @ 1"
Belimo
TF120
24 x 24
2
Intake Hood Schedule
I.D. No.
Mfr.
Model
Unit Served
Relief or
Intake
Performance Data
Opening Dimensions
CFM
S.P.
Wt.
Curb
Free Area
BDD
MAH -1
Greenheck
FGI
EF -1
Intake
2350
0.09"
82 lbs
24 x 24
4 ft ^2
MD -1
Control Schedule
I.D. No.
Mfr. & Model
Type
Controls
Power
Output
Quantity
CO
Intec SPC3 -1112
CO Sensor - Wall Mount
EF -1
24 VAC
(1) SPDT dry contacts
1
MD-1 DAMPER TO BE
SPRING CLOSE, POWER
OPEN. DAMPER WILL
OPEN WHEN EF -I IS
ENERGIZED.
EF-I WILL OPERATE WHEN
GALLED BY A CARBON
MONOXIDE SENSOR (GO).
DUCT THRU ROOF TO
135° GOOSENECK
8"0
10 "0 8' -0" A.F.F.
20' HOSE DROP FOR
VEHICLE EXHAUST
(E) 100,000 BTU
UNIT HEATER TO
REMAIN AS FOUND
25' HOSE DROP FOR
VEHICLE EXHAUST
MAR- l ON ROOF
MD-1 DAMPER TO BE
SPRING CLOSE, POWER
OPEN. DAMPER WILL
OPEN WHEN EF -I 15
ENERGIZED.
WALL SWITCH
FOR EF -3
VAC P
1/4" =
C
n
SE`�ARATE PERMIT
REQUIRED FOR:
❑ Mechanical
�Iectrical
[plumbing
E as Piping
City of Tukwila
BUILDING DIVISION
REVISIONS
No changes shall be made to the scope
of work without prior approval of
Tukwila Building Division.
NOTE: Revisions will requite a new plan submittal
and may include additional plan review fees.
G. _ NOTES
1. All duct sizes shown are clear inside dimensions.
2. All duct gauges and supports per 2009 IMC.
3. ASEI to air balance all systems to within 10% of design airflow upon project
completion.
4. All ducts to be sealed per the Washington State Energy Code.
5. Materials within ducts or plenums shall have a flame spread rating less than 25 and a
flame smoke development rating less than 50.
6. All dampers are to be installed per manufacturer's instructions.
COMPLETION
As -Built Record Drawings
1. Provide record drawings with minimum information specified in WSEC 1416.2.4.3 to
Owner within 90 days of system acceptance.
O &M Manuals
1. Provide Operating and Maintenance Manuals with minimum information specified in
WSEC 14162.4.2 to Owner.
Systems Balancing
1. Provide a written balancing report documenting testing and balancing of air systems
as specified in WSEC 1416.2.1 to Owner.
Systems Commissioning
1. All HVAC control systems shall be tested in accordance with WSEC 1416.2.3.2.
2. A Preliminary Commissioning Report shall be prepared, with minimum information
specified in WSEC 1416.2.5.1 and provided to owner.
3. A Final Commissioning Report per WSEC 1416.2.5.2 shall be prepared and filed with
the Owner.
SCOPE OF IAA:
1. Provide and install (1) exhaust fan rated at 2,100cfm to be mounted on unused roll -up door to
provide required exhaust level of warehouse space for vehicle research purposes.
2. Provide and 'install (1) Intec brand carbon monoxide sensor to control operation of exhaust fan.
3. Provide andxinstall (1) roof mounted outside air hood with motorized damper to be interlocked with
exhaust fan :operation.
4. Provide roofing services for sealing penetration made in roof for routing duct drop to warehouse
space from Outside air hood on roof.
5. Install (1) continuous exhaust fan rated at 135cfm to be mounted on unused roll -up door panel. This
fan will be controlled by a combination timer wall switch.
6. Install line vltage power to each exhaust fan and outside air damper by utilizing in -house licensed
electricians,,
FILE COPY
Permit No., 16 11- • o $
1
Plan review approval Is sued to errors and omissions.
Approval of construction documents does not authorize
the violation of any adopted code or ordinance. Receipt
of approved F .: td • and ...} ► : is adurowiedged:
� � /
,, p
BY
Date:
City Oflbkwila
BUILDING DIVISION
REVIEWED FOR
CODE COMPLIANCE
APDrn VEn
FEB 072011
L U/A-.
City of Tukwila
BUILDING DIVISION
Mu-o15
bAllentown
RECEIVED
FEB 012011
PERMIT CENTER
cL.
CaoyiIah1Saxl.(P .)- 194 3 017 6Mcrasoilfiarparalanatidrbrlb ;skimIlers..4JI dahlr resent (1.
REVISIONS
APPROVED
Battelle Research
z
Schedules,
Tukwila, WA 98168
AIR CONDITIONING /SHEET METAL /REFRIGERATION /PROFESSIONAL ENGINEERS /SERVICE Sc MAINTENANCE
BATTELLE RESEARCH
PARCEL # 2-7160000 REEVJEWED FOR
COMPLIANCE
APD Ir vFD
FEB 0 7 2011
15
City 01 Tukwjla
BUILDING DIVISION
RECEIVED
FEB 012011
PERMIT CENTER
REVISIONS
q 0
APPROVED
Gateway Dr.
C■t
C■2
CO
Tukwila, WA 98168
AIR CONDITIONING /SHEET METAL /REFRIGERATION /PROFESSIONAL ENGINEERS /SERVICE & MAINTENANCE
0