Loading...
HomeMy WebLinkAboutPermit M11-015 - BATTELLE RESEARCHBATEI.I.F RESEARCH 12822 GATEWAY DR Mi 1 -015 City 4lukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 -431 -2451 Web site: http: //www.ci.tukwila.wa.us MECHANICAL PERMIT Parcel No.: 2716000050 Address: 12822 GATEWAY DR TUKW Project Name: BATTELLE RESEARCH Permit Number: M11 -015 Issue Date: 02/08/2011 Permit Expires On: 08/07/2011 Owner: Name: RREEF AMERICA REIT II CORP/ Address: PO BOX 4900 #207 , SCOTTSDALE AZ 85261 Contact Person: Name: JESSICA BRUCE Address: 3602 S PINE ST , TACOMA WA 98409 Email: JESSICAB( ASEI.WS Contractor: Name: AIR SYSTEMS ENGINEERING INC Address: 909 S 28 ST , TACOMA, WA 98409 Contractor License No: AIRSYE *229KN Phone: 253 - 572 -9484 Phone: 206 628 -9484 Expiration Date: 02/01/2012 DESCRIPTION OF WORK: INSTALL EXHAUST SYSTEM INCLUDING THREE EXHAUST FANS AND ONE ROOFTOP INTAKE HOOD. INSTALL MAIN EXHAUST PLENUM DUCT WITH TWO FLEXIBLE HOSE EXHAUST DROPS. INSTALL CONTROL DAMPERS FOR EF -1 & MAH -1 Value of Mechanical: $6,445.00 Fees Collected: $269.31 Type of Fire Protection: UNKNOWN International Mechanical Code Edition: 2009 Permit Center Authorized Signature: Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this permit. Signature: Print Name: Date: ✓ �/ ° I This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -4/10 M11 -015 Printed: 02 -08 -2011 • • PERMIT CONDITIONS Permit No. M11 -015 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: Manufacturers installation instructions shall be available on the job site at the time of inspection. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IMC -4/10 M11 -015 Printed: 02 -08 -2011 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Mechanical Permit No. Project No. MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *please print ** SITE LOCATION ff C� ,/p King Co Assessor's Tax No.: R ! 1 190 6 60 Site Address: 1 u 2 Re-5 . L Q(1 V 1, Tenant Name: eC� �t f e-5 di Property Owners Name: R.r F �-[/1 u[ � L� /w--t I 11 CD Mailing Address: P 4166 �� # •-61 Suite Number: New Tenant: Floor: ❑ Yes ..No /4 2, 2. is, I City State Zip CONTACT PERSON - who do we contact when your permit is ready to be issued Name: e-G4 L - 0 (,(f4 Mailing Address: '3 Lsio,A 5 ` T" U fie_ St E -Mail Address: X551 C1i,b( e..061 - W5 Day Telephone: d5."3 - Ta.c00 ma. WA 4 -Oq City t="5---g t'g Fax Number: MECHANICAL CONTRACTOR INFORMATION Company Name: Air 6 n 6 t( �1 L,) g-�-,� r Mailing ddress: ✓ e . Y [ 'Ile, ✓ ✓✓ 1 aLiti W f1 g mGl, Contact Person: j ( 1 4 L / ��F&V' L^1 , , l E -Mail Address:��6 � t ll d4 . 1.0 Contractor Registration Number: ill 5 Y a (7,q f City State Day Telephone: 7 Fax Number: (. 5 -3 - 77 Expiration Date: tR "" 1 - 1 (9 ARCHITECT OF RECORD All plans must be stamped by architect of record Company Name: Mailing Address: Contact Person: - E -Mail Address: City Day Telephone: Fax Number: State Zip ENGIN ROF. COR -A Pi ans; be stamped by engine eco Company Name: Pi-if ap -1 -0 r I 1 d ' )e)(_44L - Mailin Address: '3 W ° (. om 5-F z.6 (dL. Log, . c(g `Cvq City S to ZipQ" Contact Person: [6 -6- r (.C. Day Telephone: ! -(4 7Jj • cJ ��rff KJ � �-�l • Lug F � E-Mail Address: J� � � Fax Number: ��� H:Wpplications\Ponns- Applications On Line \2010 Applications \7-2010 - Mechanical Permit Application.doc Revised: 7 -2010 bh Page 1 oft Valuation of project (contractor's bid price): $ (s) -7��`TJ,, 9 '^ / , t / Scope of work (please provide detailed information): 1.06 k .J� / '(L_k6 f 51 7` , = j ()LI LIL d S •ThSitut metuti e}c 1n v- l e r) u rr, cle.ikLbLe, d4f6 5, ►' 61 e.( (EF -(' nn 4E4 -1, Use: Residential: New ❑ Replacement ❑ Commercial: New Replacement ❑ Fuel Type: Electric Gas ❑ Other: Indicate type of mechanical work being installed and the quantity below: Unit Type; Qty Unit Type: ; Qty Unit Type: Qty Bioler /Compressor 0 -3 hp /100,000 btu Qty furnace <100k btu air handling unit >10,000 cfm fire damper furnace >100k btu evaporator cooler diffuser 3 -15 hp /500,000 btu floor furnace ventilation fan connected to single duct thermostat 15 -30 hp /1,000,000 btu suspended/wall /floor mounted heater ventilation system ' wood/gas stove b0 50 hp /1,750,000 btu appliance vent hood and duct emergency generator 50+ hp /1,750,000 btu repair or addition to heat /refrig/cooling system Incinerator — domestic other mechanical equipment air handling unit <10,000 cfm incinerator — comm/ind PERMIT APPLICATION NOTE Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 international building code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING WNER O A THO ED AGELT: Signature: Date: F r 1 1 Print Name: ae_ 41 Lat. l 1LL Mailing Address: als?-v• » Pme, Day Telephone: v� ' i. 4 Z7 q -r ma 1.01 1 Q 1(..e<4 City State Zip Date Application Accepted: �� ` 1 Date Application Expires: B - Staff Initials: ('N_ H:1Applications\Fonns- Applications On Line \2010 Applications17 2010 - Mechanical Permit Application.doc Revised: 7 -2010 bh Page 2 of 2 . • wqs City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: //www.ci.tukwila.wa.us Parcel No.: 2716000050 Address: 12822 GATEWAY DR TUKW Suite No: Applicant: BATTELLE RESEARCH RECEIPT Permit Number: M11 -015 Status: PENDING Applied Date: 02/01/2011 Issue Date: Receipt No.: R11 -00186 Payment Amount: $269.31 Initials: WER Payment Date: 02/01/2011 11:08 AM User ID: 1655 Balance: $0.00 Payee: SANDRA COLVER TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 013169 ACCOUNT ITEM LIST: Description 269.31 Account Code Current Pmts MECHANICAL - NONRES PLAN CHECK - NONRES 000.322.102.00.00 215.45 000.345.830 53.86 Total: $269.31 doc: Receiot -06 Printed: 02 -01 -2011 • INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWI.LA BUILDING DIVISION �' ... 6300 Southcenter Blvd:, #100, Tukwila: WA 98188 (206) 431 =3670 Permit Inspection Request Line (206) 431 -2451 mu oi$ ojec�t: { (�n a t1 `42 Js t Type of nspection. ACOMMENTS:.r ,_ .. Z CoANtIA,U 6441S - Ad ress ,,y,� Daye�C Ilgd /, S AA d 4CG Special Instructions: I . ,.. 04 iQ9�� e ,ls v , & - 2 Date Wanted .� f w t ! -'—„,2 m. Reque ter: f 6! It M _ -t! `' dil_ fto a & iiv 114 .4 tiot- ph // - �Vrrnit Corn 0 1-f, m (J Approved per applicable codes. CorrectionS-required prior to approval. - ACOMMENTS:.r ,_ .. Z CoANtIA,U 6441S - 7 c e a - I1 +ilii t p(en tai obi' OU - %4)l2- 6-40 iL t`Q f 9 •�,S r i"'_ gip: 6/1.!' A 1 -,Q )4--1-t ` /- Af -- "J„ -4' ,44,44---7: j ,pp,R4r x Ec (✓ 31O er i 4_ p to t1 dpi cakes F-i P 44 1, i ��n ///��� %%% t /p�/� �! �(+ �%k� r (A 4 I t a LYE+ • w t -.� \ c i t 44.Q+�8 ).0 r_AiteA • • It M _ -t! `' dil_ fto a & iiv 114 .4 tiot- 10 n.40A tif/+-� .1- A724. - // - �Vrrnit Corn 0 1-f, m (J ❑ REINSPECTION FEE REQUIRED. Prior to next inspection; fee must be paid at 6300 Southcenter Blvd:, Suite 100. Call to schedule reinspection. • sr; fdt FILE COPY CarbcP11371Mae-f001-SMIWPM Gas Detection System DESCRIPTION Wall- mounted gas monitor with built -in carbon monoxide (CO) sensor, accepts one analog remote device such as a secondary gas sensor, temperature or humidity sensor. APPLICATION To detect and control levels of carbon monoxide (CO) and other gases in a wide variety of commercial and industrial applications such as Carbon Monoxide level in parking structures, engine repair shops, equipment rooms and ventilation systems, etc. The controller can communicate with any compatible electronic analog control, DDC /PLC control or automation system via binary and /or analog output signal. FEATURES • Continuous monitoring • One (1) built -in CO electrochemical sensor • Easy plug -in sensor • One (1) remote analog input, 4 -20 mA • One (1) digital input • Two (2) relay outputs: - Four stage control - Fail -safe assignable • One (1) analog output, (0)4 -20 mA / (0)2 -10 VDC - Selectable for low, high, or averaging • One (1) 24 VDC switched output • Liquid Crystal Display (LCD) SPECIFICATIONS • LED status indicators • Accepts toxic or combustible gas, refrigerant, temperature T or humidity temperature .�� remote sensor inptjt REVIE ED Rrformance Tested & Certified • Built -in horn • Keypad user interf • Simple menu -drive programming • Modular technolog C O N T R O L S PolyGard SPC3 -1112 CE City of Los Angeles Approved CObE CO�IPLLANG n UL 2075STD APPRnvED FEB 07 1U11 • Overload & short- cfrcuit protected • NEMA 12 enclosur • Easy maintenance Electric Power Supply Power Consumption Sensor Performance Gas detected Sensor element Range Stability & Resolution Repeatability Long term ouput drift Response time Sensor life expectancy Sensor coverage Installation Location Mounting height City of Tukwila BUILDING DIVISION RECEIVED FEB 012011 r t, TCEMR Type of Control 24 VACNDC, - 20 %/ +15% General 50/60 Hz, reverse polarity protected 5 VA (0.2 A) w/ (1) remote sensor connected Carbon monoxide (CO) Electrochemical, diffusion Span field adjustable from 0 -200 to 0 -300 ppm via calibration, 0 -250 ppm factory set ± 3.0 ppm of reading ± 3.0 % of reading < 0.4% signal loss /month tso < 50 sec. 3 -5 years, normal operating environment 5,000 sq. ft., max 10,000 sq. ft. (465 m2, max 930 m2), under "ideal conditions" 5 to 6 ft. (1.5 -1.8 m) above floor Analog input Analog reading Stage level / setpoint - hysteresis/ switching differential Digital input - application Four -stage (S1 to S4) control, assignable up to two (2) binary/ relay, horn /audible alarm, and 24 VDC / 50 mA switched outputs, i.e. low -high stage for relay output, horn / audible alarm and switched 24 VDC at any stage for remote alarming One (1) 4 -20 rA, for additional remote sensor, , load < 55 mA / 200 Q, reverse polarity protected Current and mean (average) value Field adjustable over full range, four (4) stages (S1 to S4) per analog input, assignable to current or mean (average) value Selectable for each sensor point One (1); can be assigned to any relay (R1, R2). Remote audio /visual alarm reset or override function Customer Services (858) 578 -7887 & (888) GO INTEC Fax (858) 578 -4633 & (888) FX INTEC INTEC Wilson Mohr, 9730 Distribution Ave., San Diego, CA 92121 www.inteccontrols.com Specification subject to change without notice. Page 1 of 5 Printed in USA 100511 1 ,GREENHECK Building Value in Air. FILE COPY Printed Date: 1/20/2011 Job: Battelle Product Type: Fan Mark: SE 28 °SE1 24.25 AirFlow Note. Wall Housing Sizes 42 and Larger with heavy motors and all Filtered Wag Housings need additional bracing. NOTES: All dimensions shown are in units of inches Fan weight is without accessories DIMENSIONS Approx. Fan Weight (lb) Recommended Roof/Wall Opening: (in) 35 25.25 x 25.25 PERFORMANCE (Elevation ft = 1,243, Airstream Temperature F = Sidewall Direct Drive Exhaust Fan Tag SE STANDARD CONSTRUCTION FEATURES • Fan panels of galvanized steel • Aluminum blade propeller • Die formed, galvanized steel drive frame assembly • Corrosion resistant fasteners SELECTED OPTIONS & ACCESSORIES Aluminum Propeller Class B Motor Insulation or Greater UL/cUL -705 - "Power Ventilators" Motor w/ Thermal Overloads Wall Housing - Kit w/ OSHA Guard Galt'. Weatherhood 45 Degree w/ B.S. REVIEWED FOR CODE COMPLIANCE ApDonVED FEB 07 2011 City of Tukwila BUILDING DIVISION Qty Model Volume (CFM) SP (in wg) FRP M Operating Power (hp) Motor Information Size (hp) V /C /P Encl: Motor RPM: Windings 1 SE1- 18- 429 -B4 2,369 0.25 1,160 0.24 1/4 115/60/1 ODP 1160 1 Static Pressure (in wg) 1.0 0.8 0.6 0.4 0.2 0.0 LwA - A weighted sound power level, based on ANSI S1.4. Sones calculated using AMCA 301 at 5.0 ft. dBA - A weighted sound pressure level, based on 11.5 dB attenuation per octave band at 5.0 ft. dBA levels are not licensed by AMCA International. 0.5 i W¢ 0 5 RPM Curve ' 'System Curve Brake Power Curve Do not select to the left of this surge curve CAPS 4.5.1251 10 15 20 Volume (CFM) x 100 25 30 P: \Matt \wincaps \Jobs \Battelle.gcj 1 35 0.4 0.3 0.2 0.1 0.0 ke Power (hp) amca amino EMI! 1OYnD AIR nln MID cony nmot nttocmnon InitnafTlOOnt. Inc. ECEIvED FEB 01 2E1 CENTEF , Page 1 of 8 niet Sound Power by Octave Band Lwa dBA Sones 62.5 125 250 500 1000 2000 4000 8000 78 70 69 67 67 65 61 52 71 60 10.1 Static Pressure (in wg) 1.0 0.8 0.6 0.4 0.2 0.0 LwA - A weighted sound power level, based on ANSI S1.4. Sones calculated using AMCA 301 at 5.0 ft. dBA - A weighted sound pressure level, based on 11.5 dB attenuation per octave band at 5.0 ft. dBA levels are not licensed by AMCA International. 0.5 i W¢ 0 5 RPM Curve ' 'System Curve Brake Power Curve Do not select to the left of this surge curve CAPS 4.5.1251 10 15 20 Volume (CFM) x 100 25 30 P: \Matt \wincaps \Jobs \Battelle.gcj 1 35 0.4 0.3 0.2 0.1 0.0 ke Power (hp) amca amino EMI! 1OYnD AIR nln MID cony nmot nttocmnon InitnafTlOOnt. Inc. ECEIvED FEB 01 2E1 CENTEF , Page 1 of 8 e RVF SERIES EXTERIOR -MOUNT EXHAUST FANS DIMENSIONAL DATA 1 MI" A • -D model A' B C B D E RVF 4 4 101/4 13 6 23/4 RVF 4xL 4 101/4 13 6 23/4 RVF 6 6 101/4 13 6.._..........23 /4 RVF 6x1. 6 141/4...._.. 17 6 23/4 RVFBxt 8 141/4 17 .... 6 23/4 All dimensions in inches. `Duct connection is 1 /s" smaller than duct size. PERFORMANCE DATA FIVE YEAR WARRANTY VI� CERTIFIED C UL US SP. VUS MOM lank la the Energy Star Rated Models in Pafoenerce Data Dart 2. 1.4 1. ; too y 0.80 0.60 0.90 0 20 0m AIR PERFORMANCE GRAPHS 0 ihibt Es Nem ■ mai WM son IN NM mei MI IIII MIL 100 150 200 250 300 Row Rate MR 4) 350 400 450 Fan Energy Rated Max. : +' ; St agc Pre ssyreiitflnchts.Vd4; .. Max. Duct ,t _:�'4 :`; Model Star RFM Volts Watts Wattage Range Amps 0 Or 0.2" 0.4" 0.6" 0.8" 1.0" 1.5" Ps Dia. RVF 4 ✓ 3060 115 19 15 –19 0.17 134 120 112 83 37 "----- RVF4XL — 2700 115 92 73 – 92 0.84 193 180 172 154 136 118 91 — 0.78" 4" RVF6 — 2550 115 92 78 – 93 0.84 242 220 204 177 150 123 68 _— 1.27" 4" RVF6XL — 3000 115 149 145 – 157 1.46 381 360 346 315 285 258 213 64 1.74" 6" RVFBXI — 2900 115 151 140 – 155 1.42 435 410 392 348 312 282 235 102 1.82" 8" RVF Series performance is shown with ducted inlet. Per HVF's Certified Ratings Program, charted air flow performance has been derated by a factor based on actual test results and the certified rate at .1 inches WG. 500 RECEIVE FEB 0 1 2011 PERIITCENTER • ° FantechUnited States 1712 Northgate Blvd. • Sarasota, FL. 34234 • 1.800.747.1762 • www.fantech.net Item J: 450483 Canada 50 Kanalflakt Way • Bouctouche. NB E4S 3M5 • 1.800.565.3548 • www.fantech.ca Rev Date: 082208 Fantech, reserves the right to modify, at any time and without notice, any or all of its products' features, designs, components and specifications to maintain their technological leadership position. Tay: 6F-3 _ meamommosammewriaissamandes Direct Drive Pressure Blower, With Foot Mount Base Series D -FMB, 0.5 HP - 3 HP TECHNICAL. INFORMATION PROJECT: LOCATION: ARCHITECT ENGINEER: SALES ENGINEER DATE: www.monoxivent.com info@monoxivent.com 309 -794 -1000 Blower Is constructed of cast aluminum (both housing and wheel) Wheel is radial blade type TEFC motors are standard UL, CSA approved Motor is 3450 RPM Blower may be rotated (360 degrees) in 90 degree increments, allowing discharge orientation to meet requirements Provided with clockwise rotation only uoun._ a_. •_ - -. _.._. 08/230 VoT) ase: 208/230/460 Volt" 1- Phase: 1 Single ibmg base ase CFM c Static Pressure DBA Motor ode/ Model ae RPM r 2" 3" 4" 5" 6" 7" at 5' Frame X05- 005 -3 0.5 3450 450 435 390 350 260 150 -- 85 56 D1r -1 010 -3 1.0 3450 -- -- -- 770 665 540 320 -- 83 56 D15- 015 -3 1.5 3450 965 910 840 780 675 550 330 - -- - -- 83 56 D20 -1 020 -3 2.0 3450 - -- -- 1237 1140 1070 990 915 825 735 86 145T 030 -1 030 -3 3.0 3450 1490 1420 1275 1213 1140 1070 990 915 825 86 145T Single Phase: 115/230 Volts; Three Phase: 208/230/460 Volts 10.5" Wheel: D05; 12" Wheel: D10, D15; 13.5" Wheel: D20, D30 -= Unstable operating range 0 Series Dimensions Model Wheel Dia. Jnlet Dia. Outlet Dia A B Q Ja E a H. I ,J 6 005 10.75 5 4 9.25 6.5 7.5 7.5 6.25 5.13 12.25 3.25 5 4 11.5 C 10 ) 11.63 7 D15 11.63 7 D20 13.5 7 D30 13.5 7 6 12 7.5 10 9 8 5.13 12.25 3.25 7 6 13.25 6 12 7.5 10 9 8 5.13 12.25 3.25 7 8 13.25 6 12 7.5 10 9 8 5.13 12.25 3.25 7 6 14 6 12 7.5 10 9 8 5.13 12.25 3.25 7 6 14 RECEIVED FEB 011Q - io TCFATER arm ho x cavity 1 Mode F'GI A 7/8 Throat Width Curb Cap Width Qimensio al Optional ; Damper Width x Length ;Throat: Throat Area Width x Length Curb Cap Width x Length All dimensions shown in inches Throat Length Curb Cap Length Hs- 11/2 ti 0 030 0.047 0.07 0.089 0.119 0.-149 0.196 " a 11 1 NON DUCT60 STATIC PRESSURE DROP (IN, VViy p .21 mi 0.053 , 0.085 0.127 ! 0.158 0.212 0.267 ; 0.350 . •a m s (Fr /MIN) ..........1 ..........:.. 527/1065604/1220 4262 4880 5328 6100 } 6393 7320 • 7459 _8539 ; 8524` 9759 9590 19979..' 10655 ; : 12199.. 11721 „13419 ' !! ; 12786 14639 HOOD INTAKE VELOCITY../ THROAT VELOCITY 235/475 297/600 ; 364/735 406/820 , 4.70/950 yiu 4.00• 24' x 24.1..48 x 30 24„x24, 52 39 19 . 5 , 1899 2405 2939 3279 3798 5;00 24.x•30, ;, 30_ 36, 24 x 30 ; 49 51 1.9 ; 5 . 2374 3005 „,3874 4998 4747 6 00 24. x 36 1!.k41.5 x 42, 24.x 36 47, 63',19 I • 5 ' •2848 , ' , 3607. I 4.469.,;,11 4998 + • 5897_ 700 _' 24 x 42 ; 30 x 48 24 x 42 54 , 63 , 19 . 5 i 3329 I 4208 5144., 5738 6646 • 8 00 : 24 x 48 30 x 54... 24 x 48 ` 52 '. 75 ' 19 5 I,,. 3798 ' 4809 , 5679 6557 - 7596m, 9.00 24x54_•, 30.x60 24x54 : 50 ,87 19 ; 5 • 4272 5411 6614 7377 8545 1.0 00 ; 24 x 60 .30 x 66 24 x60' 55 ' :87 • 19 • 5 4747 6012 7349. .8196. . 9494._ 11..00 : 24 x 66. ! 30 x 72....ri 24x 66 54:99 : 19 5 5222 : I 6613 8093 I • 9016 10444 112.00 24x 72 30 x78 24 x 72 58. l 99 19 5 5697 7214. 8818 9836 ,, 11393 ..13.00 24x 78 [ 30X:84 .., 24 x78 56 111 19 5 6171 7815... 9553 10655 ! 12343 14.00 24 x 84 , 30 x 90 24x84 : 60 ..111 ! 19.... 5 6646 8417, 10288 11.475• • 13292 15.00 24x 90 .30: x 96 .' 24;x;90 58 `.123 19 • 5 . 7121 9018. : 11023 12295 ' 14242 . •6.25 ' 30x 30 1 36 x 36... 30x 30 60; 51 ; 19 • 5 2967 3757 4593 5123 5934.. . 7.50 30 x 36 :36 x 42 30 x 36 58 63 19 5 3560 . 4509 5511 . 6147 7121 8.75 • 30 x 42 36 x 48 30 x 42 • 57 75 : 19 5 4154 5260 6430 ; 7172 8308 10.00 30 x 48 1 36 x 54 30 x 48 64 75 19 5 4747 ! 6012_._ 7349 8196 9494 11.25 30x 54 ,.; 36 x 60.., 30 x54 62 .. 87 : 19 5 5341 6763 8267 ' 9221 10681 • 12.50 30 x 60 ; _36 x 66 I 30 x 60 ' 60 99 19 5 5934 7515 i 9186 10246 11868 ,13.75; 30 x66 : 36 x 72 I 30 x 66 66 • 99 ;19 5 ; 6527 : 8266 10104 11270 j 13055 ........ 71 _._. 11023 12295 , 14242 15.00 30 x 72 36 x 78 30 x 72 64 i. 111 • 19 5 21 9018 .25 ! 30 x78 36 x84 7714 9 629 11941 1 13319 15428 17.50 30 x 84....36 x 90 30 x 78 . 67 123: 19 5 7 __. .... 7 4 8__. 10. 1 12860 14344 16615 18 75 30 x 90 • 36 x 96 , 30 x 90 ! 72 ; 123: 19 • 5 8901 . 11272 13779 15368 17802 9:.00: 36 x 36 42 x 42....:;. 36 x36 .... 69. ; 63 ; 19: 5 • 4272........ :5411 661:4;. 1•• 7377 ,18545 10:50.•;• 36.x 42 42 x 48 36 x 42, 67 : 75 19 5 4985 6312 :.: 7716 9606•:;,;;; 9969 • • 12.00. 36 x 48; 42 x 54 ,1 36x 49 ; 66 87 : 19 5 5697 : 7214,.,. 8818 9836 11393 . 13.50 30x 54 42 x 60 ; 36 x 54 73 87 19 • 5 6409 :1 8116 ; 9921 11065 12817 15.00 36 x 60 t 42 x 66 ; 36 x 60 72 ! 99: ; 19 5 7121 9018. 11023 12295 14242 . 16.50 36 x 66 : 42 x 72 36 x 66 78 ' 99 19 . 5 7833 9930. .1._ 12125 13524 15666 18.00 36x72..,: 42x 78 36 x 72 76' 111; 19•5 8545 : 10821,. 13227 14754 17090 • 19.56; 36x 78 x42 x 84 ; 36 x 78 74 123 - .19 5 9257 11723 14330 15983 ; 18514 22.50 36 x 90 421x 96 36 x 90 78 135::••19., 5 10681 i 13527 16534 184 , 29332 21.00 : 36 x 84 42 x90 36 x 84 80 123 19.;! 5 9969 12625 15432 17213 42 4 "21362, • 24.00 36 x 96 42x 102. q§)...5....94. • 83 ? 135 , 1:9 ' 5 ; ,.11393, 1 14428.. 17637 , : 19672 • 22787 25.50: 36 x10? i 42 x 108 ::.36 x 102 81 A47 19 • 5 12105 15330 18739 20901 24211 . 12.25 42. x 42 .48 x 48. 42 x 42 78 75 .;. 23 : 5 ' 5815 ' 7365 ; 9002 10.041 11631 • 14.00 42 x 48 48 x 54. 42 x 48 76.87: 23 • : 5 • • 6646 8417 10288 11475 13292 • 15.75 ,, 42 x.54. 48 x.60 42,x 54. 85 87 , 23 5 7477 9469 . 11574 12909 14954 17.50 42 x 60. !48 x 66. 42 x 60 83 99 ; 23 , 5 r 8308 10521 ; 12860 • 14344 16615 19.25 42. x 66 48 x 72 42 x66 : 81 :111 • 23 ; 5 i 9138 11573 14146 , 15778 • ,..18277 : 21.00 ; 42. x 72 48 x 78__. 42 x 72 88 :111 ' 23 ! 5 9969 . 12625 15432 17213 19938 . 22.75 • 42. x 78 : 48 x 84 42 x 78 86 1 1231.23 : 5 10800 13677 16718 ' 18647 21600 24.50: 42 x 84. 48 x 90 . ` 42 x 84 84 1135;i; 23 5 . 11631 147.2.9....j. 18004 20081 23261 26.25 ' 42. x 90 :.48x•96•• , 42 x_90 90 i 1351 23 5 :.12461 . 15781 , 19290 • 21516 24923 28.00 42.x 96 : 492c 102., 42 x.96 , 88 ;147 ; 23 5 13292 16833 20576 22950 1 26584 29.75 42 x 102 48x 108 42 x 102 93 :147: 23 .5 14123 17885 21862 • 24385 1 28246 31.50 42 x 108 48 x 114 42 x 108 91 .159 23 5 14954 18937 23148 25819 29907 16.00. 48 x 48 54.x 54 ' 49:x 48. 86 • 87. 25. 5.... 7596 9619 11758 13114 . 15.191,. 18 :00 48 x 54 54 x 60 48 x 54 • 85 99 , 25 5 8545 10821 13227 14754 1.709D 20.00 48 x60 54 x 66 48,x.60 94 99:25 5 .. 9494 12024. 14697 16993 18989 . 22.00 48 x 66 54 x 72. 48x66 92. 111 25 5 . 10444 - 13226 16167 18032 20888 24.00 .48 x 72 . 54..x• 78:.. 48 x 72 90..123. 25 : 5 .:.11393 14428 17637 19672 22787 26.00 48 x.78 54 x 84 48 x 78 98 " 123 ' 25 5 12343 15631 19106 21311 24685 28.00 48 x 84 54 x 90 48 x•84 92 ;135 25 5 13292 16833 20576 22950 26584 30.00 48x 90•. " 54 x 96.....;:48:x90 s .98".:135. 25 5 14242 18036 22046 24589 28483. 32.00 • .48 x.96.: 54 x 102 - 48 x;96 96 147... 25 5 15191 19238. 23515 26229 30382. 34.00 48 x 102: 54 x 108.•••••;;48.,x 102 94 1591 25 . 5 16140 20440 24985 27868 32281 36.00 • 48 x 108 54 x 114 48 x 108 100 159' 25 . 5 17090 21643 26455 29507 34180 38.00 48 x 114 54 x 120. 48.x 114 98 171 25 5 18039 22845 27924 31147 36079 0 <1 POUNDS Yes i 82 ,. Yes 91 • Yes,_! Yes . 163 Yes 174 Yes ; 185" ,13852 15859 Yes „!, 14917 17079.. Yes 230. rvl 15983. . 18299. • 6659 : 7625.. • Yes 108 .7991 • 9149 Yes 119_. _ 9323 10674 Yes „10655_ • 12199 Yes , 43 , 1 11987., 13724 , Yes 174 13319 15249 Yes ; 186, 14651 16774 Yes 1 200 15983 I 18299 Yes 225 17314 19824 Yes ; 251 18646.,_,. 21349 Yes ' _ 264 ;.. 19978 22874 Yes 278! 9590 1,Q979.. Yes : • .11188 12809.... Yes ' 141_.. :12786 ` 14639! Yes.1_ •176. 14384! 16469 Yes,' 198,_..., y 15983 18299:_:. Yes 208, ! 17581 20129 Yes 214.• 19179 :: 21959 Yes_! 252 20777 23789. " Yes _j. 280. • 22376 r 25618 "1 •Yes, 295 23974 27448•_; Yee 311 '2,5512 29278 Yes ; 324 ,27170,..,,, 31108 .! No 340 13052 14944. Yes 178. 14917 17079 Yes 221 16782 ` 19214 1 Yes ! 252 18646 21349 Yes 261 20511 23484 i Yes ' 291 .22376 25618,•, Yes ' 320 24240 •._.27753 Yes 355 26105 29888 Yes___ 373._. 27970 32023 Yes E 392 29834 34158, No.. , 412_ 31699 36293 No 429 33563 38428 : No 450 17048 19.519 Yes. 257 1.9179: ;21959 • Yes.•: .278 21310 24399 ,Yes ;299 23441 26838 Yes.I 832.... 25572 ..29278 Ye,.� 353 277,03 . 31718 .:... •N,.0<... 383. .. :298.34.: 341:58; ' NQ 441:2 31965 34096 36227 41478 . j No rip • 38358 40489 2O 4 `1Vb X117 PERMIT CENTER 9 06 -30 -2011 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director JESSICA BRUCE 3602 S PINE ST TACOMA WA 98409 RE: Permit No. M11 -015 12822 GATEWAY DR TUKW Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and /or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 08/15/2011. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period, , provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 08/15/2011, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, 'IA ---'81 Bill Rambo Permit Technician File: Permit File No. M11-015 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 • N �1 • PE PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M11 -015 PROJECT NAME: BATTELLE RESEARCH SITE ADDRESS: 12822 GATEWAY DR X Original Plan Submittal Response to Incomplete Letter # DATE: 02 -01 -11 Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: 1 building Division Public Works ,4w\ N% Fire Prevention Structural n Planning Division Permit Coordinator Ilk DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 02 -03 -11 Complete '711 Incomplete ❑ Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route 7 Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Notation: Approved with Conditions DUE DATE: 03 -03 -11 Not Approved (attach comments) ❑ REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 Contractors or Tradespeople Prater Friendly Page • General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name AIR SYSTEMS ENGINEERING INC UBI No. 600099211 Phone 2535729484 Status Active Address 3602 5 Pine St License No. AIRSYE'229KN Suite /Apt. License Type Construction Contractor City Tacoma Effective Date 5/15/1978 State WA Expiration Date 2/1/2012 Zip 984098197 Suspend Date County Pierce Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Business Owner Information Name Role Effective Date Expiration Date CRAWFORD, KANDI K President 01/07/2010 Bond Amount COLYER, SANDRA K Secretary 01/07/2010 08358752 GEORGE, WILLIAM Vice President 01/27/2010 CRAWFORD, DOUGLAS D Vice President 01/07/2010 VIGILANT INS CO ANDERSON, CURTIS M 02/01/2008 01/01/1980 01/07/2010 ANDERSON, LORINE $12,000.00 01/01/1980 01/07/2010 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 8 FIDELITY & DEPOSIT CO OF MD 08358752 02/01/2010 Until Cancelled $12,000.00 01/27/2010 7 VIGILANT INS CO 82138376 02/01/2008 Until Cancelled $12,000.00 02/04/2008 6 TRAVELERS CAS & SURETY CO 081510353581BCN 02/01/2002 02/01/2008 $12,000.0001/15 /2002 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 30 LEXINGTON I INS 014180670 11/01/2010 11/01/2011 $2,000,000.00 10/25/2010 28 LEXINGTON INS CO 049159165 11/01/2009 11/01/2010 $2,000,000.00 11 /02/2009 27 CO LEXINGTON INS 004052434 11/01/2008 11/01/2009 $2,000,000.00 11/06/2008 26 ACE AMERICAN INS CO HDOG23734941 11/01/2007 11/01/2009 $2,000,000.00 10/15/2008 25 CONTINENTAL CASUALTY CO 2048527545 02/01/2007 02/01/2008 $1,000,000.00 01/16/2007 24 TRANSPORTATION INS CO TCP2048527545 02/01/2004 02/01/2008 $1,000,000.00 01/10/2007 Summons /Complaint Information Cause County Complaint Judgment Status Payment Paid By 07 -2- 06730 -8 PIERCE Date: 07/16/2007 https://fortress.wa.gov/lni/bbip/Print.aspx Date: Open Date: 02/08/2011 Contractors or Tradespeople Poter Friendly Page HRISTOPHER E WALLIS nterPlead: No Warrant Information Education Information Amount: $0.00 Amount: $0.00 0 Amount: Page 2 of 2 https: // fortress .wa.gov /lni/bbip/Print.aspx 02/08/2011 EF -2 TO RUN CONTINUOUSLY. SHEET METAL SCREW I" x 24 GA. GALV. SHEET METAL STRAP; SECURE UNIT TO CURB AT EACH CORNER WOOD SCREW INTO GURB NAILER METAL FLASHING BY ASEI RUN ROOFING TO TOP OF CURB GASKET BY A5E1 CURB NAILER. INSULATION ALL AROUND CURB, MAX. THICKNESS TO MATCH CURB NAILER GANT BY OTHERS Rooftop II VAC Not to Scale nit FACTORY ROOF CURB BY ASEI LEVEL BASE nstcllctio De�ai Fan Schedule I.D. No. Area Served Mfr. Model Type CFM S.P. RPM Sones Voltage Ph. HP or W Op. Wt. BDD Controlled By Notes EF -1 Testing Area Greenheck SE1 Side wall direct drive 2,350 0.25" 1160 10.1 115 1 1/4 HP 35 lbs. MD -1 CO Sensor EF -2 Testing Area Fantech RVF 4XL Exterior mount 180 0.1" 2700 N/A 115 1 92 W 20 lbs. None Continuous operation EF -3 Testing Area Monoxivent D10 Centrifugal Blower 700 4.5" 3450 N/A 115 1 1 HP 100 lbs. Internal Wall Switch Control Damper Schedule I.D. No. Mfr. Model Type Damper Leakage Actuator Size Quantity Mfr. & Model Voltage MD -1 Greenheck VCD -23 Low Leakage Control Damper 3 CFM @ 1" Belimo TF120 24 x 24 2 Intake Hood Schedule I.D. No. Mfr. Model Unit Served Relief or Intake Performance Data Opening Dimensions CFM S.P. Wt. Curb Free Area BDD MAH -1 Greenheck FGI EF -1 Intake 2350 0.09" 82 lbs 24 x 24 4 ft ^2 MD -1 Control Schedule I.D. No. Mfr. & Model Type Controls Power Output Quantity CO Intec SPC3 -1112 CO Sensor - Wall Mount EF -1 24 VAC (1) SPDT dry contacts 1 MD-1 DAMPER TO BE SPRING CLOSE, POWER OPEN. DAMPER WILL OPEN WHEN EF -I IS ENERGIZED. EF-I WILL OPERATE WHEN GALLED BY A CARBON MONOXIDE SENSOR (GO). DUCT THRU ROOF TO 135° GOOSENECK 8"0 10 "0 8' -0" A.F.F. 20' HOSE DROP FOR VEHICLE EXHAUST (E) 100,000 BTU UNIT HEATER TO REMAIN AS FOUND 25' HOSE DROP FOR VEHICLE EXHAUST MAR- l ON ROOF MD-1 DAMPER TO BE SPRING CLOSE, POWER OPEN. DAMPER WILL OPEN WHEN EF -I 15 ENERGIZED. WALL SWITCH FOR EF -3 VAC P 1/4" = C n SE`�ARATE PERMIT REQUIRED FOR: ❑ Mechanical �Iectrical [plumbing E as Piping City of Tukwila BUILDING DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will requite a new plan submittal and may include additional plan review fees. G. _ NOTES 1. All duct sizes shown are clear inside dimensions. 2. All duct gauges and supports per 2009 IMC. 3. ASEI to air balance all systems to within 10% of design airflow upon project completion. 4. All ducts to be sealed per the Washington State Energy Code. 5. Materials within ducts or plenums shall have a flame spread rating less than 25 and a flame smoke development rating less than 50. 6. All dampers are to be installed per manufacturer's instructions. COMPLETION As -Built Record Drawings 1. Provide record drawings with minimum information specified in WSEC 1416.2.4.3 to Owner within 90 days of system acceptance. O &M Manuals 1. Provide Operating and Maintenance Manuals with minimum information specified in WSEC 14162.4.2 to Owner. Systems Balancing 1. Provide a written balancing report documenting testing and balancing of air systems as specified in WSEC 1416.2.1 to Owner. Systems Commissioning 1. All HVAC control systems shall be tested in accordance with WSEC 1416.2.3.2. 2. A Preliminary Commissioning Report shall be prepared, with minimum information specified in WSEC 1416.2.5.1 and provided to owner. 3. A Final Commissioning Report per WSEC 1416.2.5.2 shall be prepared and filed with the Owner. SCOPE OF IAA: 1. Provide and install (1) exhaust fan rated at 2,100cfm to be mounted on unused roll -up door to provide required exhaust level of warehouse space for vehicle research purposes. 2. Provide and 'install (1) Intec brand carbon monoxide sensor to control operation of exhaust fan. 3. Provide andxinstall (1) roof mounted outside air hood with motorized damper to be interlocked with exhaust fan :operation. 4. Provide roofing services for sealing penetration made in roof for routing duct drop to warehouse space from Outside air hood on roof. 5. Install (1) continuous exhaust fan rated at 135cfm to be mounted on unused roll -up door panel. This fan will be controlled by a combination timer wall switch. 6. Install line vltage power to each exhaust fan and outside air damper by utilizing in -house licensed electricians,, FILE COPY Permit No., 16 11- • o $ 1 Plan review approval Is sued to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved F .: td • and ...} ► : is adurowiedged: � � / ,, p BY Date: City Oflbkwila BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE APDrn VEn FEB 072011 L U/A-. City of Tukwila BUILDING DIVISION Mu-o15 bAllentown RECEIVED FEB 012011 PERMIT CENTER cL. CaoyiIah1Saxl.(P .)- 194 3 017 6Mcrasoilfiarparalanatidrbrlb ;skimIlers..4JI dahlr resent (1. REVISIONS APPROVED Battelle Research z Schedules, Tukwila, WA 98168 AIR CONDITIONING /SHEET METAL /REFRIGERATION /PROFESSIONAL ENGINEERS /SERVICE Sc MAINTENANCE BATTELLE RESEARCH PARCEL # 2-7160000 REEVJEWED FOR COMPLIANCE APD Ir vFD FEB 0 7 2011 15 City 01 Tukwjla BUILDING DIVISION RECEIVED FEB 012011 PERMIT CENTER REVISIONS q 0 APPROVED Gateway Dr. C■t C■2 CO Tukwila, WA 98168 AIR CONDITIONING /SHEET METAL /REFRIGERATION /PROFESSIONAL ENGINEERS /SERVICE & MAINTENANCE 0