Loading...
HomeMy WebLinkAboutPermit M11-028 - JC PENNEYJ C PENNEY 1249 SOUTHCENTER MALL EXPIRED 12 -13 -11 M11-028 City (*Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspectio n Request Line: 206- 431 -2451 Web site: http: / /www.ci.tukwila.wa.us MECHANICAL PERMIT Parcel No.: 9202470010 Address: 1249 SOUTHCENTER MALL TUKW Project Name: J C PENNEY Permit Number: M11 -028 Issue Date: 03/30/2011 Permit Expires On: 09/26/2011 Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA 92013 Contact Person: Name: LARRY MAYOTTE Address: 22745 29TH DR SE, SUITE 100 , BOTHELL WA 98021 Email: LAWRENCE.A.MAYOTTE @JCI.COM Contractor: Name: JOHNSON CONTROLS, INC. Address: PO BOX 2012 , MILWAUKEE, WI 53201 Contractor License No: JOHNSC *2720S Phone: 425 419 -3916 Phone: 425 - 827 -7810 Expiration Date: 10/23/2012 DESCRIPTION OF WORK: REPLACEMENT OF B.A.C. COOLING TOWER WITH CUSTOMER PROVIDED EVAPCO COOLING TOWER. Value of Mechanical: $99,400.00 Type of Fire Protection: UNKNOWN Electrical Service Provided by: Permit Center Authorized Signature: Fees Collected: International Mechanical Code Edition: Date: $1,309.56 2009 l I hereby certify that I have read and examin- ` this pe J t and know the same to be true and correct. All provisio o law an ordinances governing this work will be complied with, whether s / cified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this permit. Print Name: /qeg 4 ,j4 iciyeTrap This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Date: _006( doc: IMC -4/10 M11-028 Printed: 03 -30 -2011 • PERMIT CONDITIONS Permit No. M11-028 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: The special inspections for steel elements of buildings and structures shall be required. All welding shall be done by a Washington Association of Building Official Certified welder. 5: Installation of high- strength bolts shall be periodically inspected in accordance with AISC specifications. 6: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 7: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. 8: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 9: Manufacturers installation instructions shall be available on the job site at the time of inspection. 10: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 11: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431- 3670). 12: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IMC -4/10 M11-028 Printed: 03 -30 -2011 CITY OF TUKIh,.A Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 httol/www.ci.tukwila.wa.us Mechanical Permit No. % f' Project No. (For office us e only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *please print ** SITE LOCATION Site Address: 1 2 MAC_ King Co Assessor's Tax No.: Suite Number: Floor: Tenant Name: A3k) New Tenant: El Yes j,..No Property Owners Name: to-es.t -f t t Id :f rou p Mailing Address: City State Zip CONTACT PERSON — who do we contact when your permit is ready to be issued Name: LA eel K'U' foirr Day Telephone: 426- - 911 - .31 l (o Mailing Address: 22.7 1 S 2'1 1-"' r `]r , SO,-t /OD 6c nl _ COA �F,c�21 City State Zip Fax Number: 42 S" - 301 e, - (c /1,56 E -Mail Address: / 4 ' .e €.nst C.. /4_ k.4 A t(o rrr j C t t e i - MECHANICAL CONTRACTOR INFORMATION Company Name: Mailing Address: 1►Jc- 2774 21'n1 t2 �� 5 :7 100 -Z4:571-1FLA City Contact Person: 1At2J2-` /WA 7T �JA State 18ort Zip Day Telephone: zas - y ►y - 351(0 E -Mail Address: / At.o czeA3ce_ , A . 4 /o rrE_ 1. c vr^i Fax Number: Li ZS - 3r1h - (0`1SZ) 10[2,[ Ls Contractor Registration Number: 30 Y 'vee t •f-1 Lc‘, Expiration Date: ARCHITECT OF RECORD — All plans must be stamped by, architect of record Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: State Zip ENGINEER OF RECORD — All plans must be stamped by engineer of ecord Company Name: Mailing Address: Contact Person: A 60 As Y r'l1 0N(; i, a.i t,zj.-1,vC+l L_I__L 7Ioc i17 *" Ave .-*C-- 2cl_ 6f.t.LCva:.. City State Zip Day Telephone: LIZS- - u6/2. - 41441 LA) RCN . i1ABtJ Lk)°AAA( k E -Mail Address: 61A a1.. We?AAALL (( ARcvAg1n . ccw1 Fax Number: 4Z5 - y(OL. - '1415-1 H :\Applications\Forns- Applications On Line \2010 Applications \7 -2010 - Mechanical Permit Application.doc Revised. 7-20W bh Page 1 of 2 • • Valuation of project (contractor's bid price): $ �1� 400 "na' Scope of work (please provide detailed information): RQp,_AcpM(nor etr Z.A C. CooLIA(.14 -TOWER W1--0% (vsrnnnr.2 eaevioro CVAPU A3c-, TOWER. Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement Fuel Type: Electric gi Gas ❑ Other: Indicate type of mechanical work being installed and the quantity below: Unit Type: Qty Unit Type: . Qty Unit Type: Qty Bioler /Compressor Qty furnace <100k btu air handling unit >10,000 cfm fire damper 0 -3 hp /100,000 btu furnace >100k btu evaporator cooler 1 diffuser 3 -15 hp /500,000 btu floor furnace ventilation fan connected to single duct thermostat 15 -30 hp /1,000,000 btu suspended/wall/floor mounted heater ventilation system wood/gas stove 30 -50 hp /1,750,000 btu appliance vent hood and duct emergency generator 50+ hp /1,750,000 btu repair or addition to heat/refrig/cooling system Incinerator — domestic ee meical eqghuipp mennhant air handling unit <10,000 cfm incinerator — comm/ind 'PERMITIAPPLICATIOWNOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 international building code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Name: \k\N‘ 414)A-/\ ��OY Mailing Addr ess: Date Application Accepted: d ?, /, De 5E Date: 2 I 1 \ Day Telephone: 'I2- S 1 I `' 3 I Ib -14141 I City �,pc 95oz1 State Zip Date Application Expires: 08415-iii Staff Initials,4 ki H:\Applications\Forms- Applications On Line\2010 Applications \7 -2010 - Mechanical Permit Application.doc Revised: 7 -2010 bh Page 2 of 2 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http:/lwww.ci.tulcwita.wa.us RECEIPT Parcel No.: 9202470010 Permit Number: M11 -028 Address: 1249 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 02/25/2011 Applicant: J C PENNY Issue Date: Receipt No.: R11 -00346 Payment Amount: $1,309.56 Initials: LAW Payment Date: 02/25/2011 11:37 AM User ID: 1632 Balance: $0.00 Payee: JAN GOUGH TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 095464 ACCOUNT ITEM LIST: Description 1,309.56 Account Code Current Pmts MECHANICAL - NONRES 000.322.102.00.00 PLAN CHECK - NONRES 000.345.830 Total: $1,309.56 1,047.65 261.91 doc: Receiot -06 Printed: 02 -25 -2011 4SPECTiONRECCR/,4 LI � 6Z1 }R p y pmit INSPECTION NO. PERMIT NO. .. CITY' OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 ‘e- (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Proj ct: 6e. �ENi,.)F9 Typ�a�o,f Inspection: f���Gq' Date Called: C AJ me J, Adi 2, ..±49 S M. , C , ! _ Special Instructions: y r 1 �/ la Date Wanted: — I — •�.m.: —1/ Req / c. 12 Phone No 4ZS -1 15 -31,t,61 Approved per applicable codes. a Corrections required prior to approval. - — CO MMENTS: (2) R t nn l J % p 4/4AL -J 0; n I IAaiG - 0 re 6 / r 1 �/ la - 0^, A r z Rte. - ;NJ -apVAltq 1 nspect • f: Dat : ri EINS ° ECTION FEE REQUI' D. Prior to r1ext inspection, fee must be t aid . t 6300 Southcenter. Blvd Suite 100. Call to schedule reinspection. waRa.��VfY AAAA 25' 90' Mechanical Mezzanine 65' 250' 10 co 'c� REVIEWED FOR � ��OMPLIANCE t,u -,1 (, 1 4c, t ; Cityof Tukwila BUILDINR nriiicrnn► oacENED FEB 25 2011 QERMR CENTER Drawing Title Visio - Roof Plan REFERENCE DRAWING Santa Enginaar prop,. Manapar Larry Mayotte NO. ApnII ation Enpnwr Project Title JC Penny Cooling Tower Replacement J'. Johnson /� fi Controls REVISION - LOCATION DRAWN BY LM I DATE 2/24/2011 Branch Information ECN DATE BY APPROVED BY I DATE CONTRACT NUMBER 1- 2293827498 DRAWING NUMBER Roof Plan Structural Calculations for Permit Submittal JC Penney Cooling Tower REVIEWED ANCE CODE COMPLIANCE AcconvFo MAiK 21 1011 City of Tukwila BUILDING fIVlClflna 1200 Southcenter Mall Tukwila, WA Client: Abossein Engineering Date: February 2, 2011 ECEVED CITY OF TUKWIL4 'FEB 2.5.2011, PERMIT CENTER irnl -Od8' Seismic Design Loads (ASCE 7 -05) for attachment of Mechanical Equipment at roof OCCUPANCY CAT. 1 . Table 1 -1 IMP. FACTOR 1 Table 11.5 -1 SITE CLASS d Table 20.3 -1 SEISMIC Rp = 6.0 Table 13.6 -1 DESIGN CATEGORY D 11.6.1.1 ap = 2.5 Table 13.6 -1 S8= 1.423 S1= 0.487 Fa = 1.00 Table 11.4 -1 F„ = 1.51 Table 11.4 -2 hx/r 1.0 Sos= 0.949 Sp,= 0.491 FPuLr= FPnsn= 0.474 xW 0.339 xW Vertical Design Loads Eqn. 13.3 -1 FPmin= Fp,naX 0.28 xW 1.52 xW Live Loads Snow (roof) 25 psf Project: JC Penney Date: 2/1/2011 Southcenter Project #: 0029 - 2011 -02 Design: EAF Sheet Criteria 1 Wind Design Loads (ASCE 7 -05) Method 2 - Analytical Procedure Exposure b Roof Angle = 0 degrees V= 05 mph Ground to top of roof 50 ft Kd= 0.85 Table 6-4 Bottom of roof to top of roof 0 ft I= 1 (mean roof height) h= 50 ft G= 0.85 6.5.8.2 Kt= 1.00 Section 6.5.15.1 F= 1.9xgZGCfAf Egn.6 -28 q: C+f 14 psf 1.4 F= 31.7 psf xAf Pressures: Pressure Coefficients from Figure 6-6: Bldg Face Cp Windward Wall 0.8 Leeward Wall -0.5 Windward Roof 0 Leeward Roof -0.6 *Note= Cp values are conservative worst case values Ht Kz qZ Pwwwalls Phinvalis PwaUs (Psf) 0 -15 0.57 8.96 6.09 5.41 11.51 15 -20 0.62 9.75 6.63 5.41 12.04 20-25 0.66 10.38 7.06 5.41 12.47 25 -30 0.7 11.01 7.48 5.41 12.90 50 0.81 12.73 8.66 5.41 14.07 P.m roof Pew roof Proof (psf) 0.00 6.49 6,49 Project JC Penney Date: 2/1 /2011 Southcenter Project #: 0029 - 2011 -02 Design: EAF Sheet Criteria 2 Conterminous 48 States 2005 ASCE 7 Standard Latitude = 47.45863 Longitude = - 122.25536 Spectral Response Accelerations Ss and S1 Ss and S1 = Mapped Spectral Acceleration Values Site Class B - Fa = 1.0 ,Fv = 1.0 Data are based on a 0.05000000074505806 deg grid spacing Period Sa (sec) (g) 0.2 1.423 (Ss, Site Class B) 1.0 0.487 (S1, Site Class B) Conterminous 48 States 2005 ASCE 7 Standard Latitude = 47.45863 Longitude = - 122.25536 Spectral Response Accelerations SMs and SM1 SMs = Fa x Ss and SM1 = Fv x S1 Site Class D - Fa = 1.0 ,Fv = 1.513 Period Sa (sec) (g) 0.2 1.423 (SMs, Site Class D) 1.0 0.737 (SM1, Site Class D) Conterminous 48 States 2005 ASCE 7 Standard Latitude= 47.45863 Longitude = - 122.25836 Design Spectral Response Accelerations SDs and SDI SDs= 2/3x SMs and SD1 = 2 /3xSM1 Site Class D- Fa= 1.0,Fv =1.513 Period Sa (sec) (g) 0.2 0.949 (SDs, Site Class D) 1.0 0.491 (SDI, Site Class D) CR3 sp� D � 17L p e r _ p r 1, 11 114 CO �D121G ' (() CoO�l►�G TO w6i2 / U nl 1 "iff. : Lbl M s s i d m 3 Ct- j -1A4 AtsD_A7til,Crt nl (-tW7 41 N 17-15 , - j New 4 oie tot,* A 4 = (-0 D✓, l S ' 423,!//z 311-1 2-1.10 4 i/i I/a aCo.-/ Itzou //2: — . (WS-1,W! a .r . g of 4- �' _ (f Z. >..7?-..o _ - 7' = 1 - l i_x 2r' �f i t. 3 . 177-7k0.3 S_ . -- _ PEA-A4 A 517EFQ.1 -d. .1 Z F►2A-ME._. > W S P4v I b _ PL,L,uii-1 ?-1 CI -- ,--,--FM.A'i? — (E����t� , ,_ ..r _� • _ Cow- J Kt Li • iiil-Pg4 . �. UOI$ 01 J h G i_S�/ �,>• i2.1 .636." O L 0 ' Illti ii/ Mii 1 EX(611tJ r . , 1 N_C_ UIJ ► M 1'Z WI : 2.0. +SJp _ Y�--r u) =-_ _ Q. 55 to i'o , J- - : . — 42.3, ,1�'r. M 0b. i UNLIT, :W_ : 0‹_ - 4qr . < Qc (S NGt = ICI** /MS' r.T1 da��..41�� ∎•►... �._ H ;- k tiq .0 .. , OT-. _ _ !M1h? - Pu T71 I2.:bo.. /.) _774. , : oT'_;.. _ M,, 3 0 .*1 211: : -L U to a l .FRANK. FRANK CO. 4742 42nd Ave SW #297 Seattle, WA 98116 Ph_ 206579.8160 Pro, J Peinn 30-IA-HA newly( 0-1Z- 11 Date 009 —Zo1 1 02— Prof. No� Design Sheet 0.3361( Up 1404+) (ku.ew�,,� 31.1- �C219 I'k - CO 500 . 6-At to 0E: . ... -T188 A-551A (6) 5%b 01101e . 136 spy .pL -2s 6 Disr - aUev) Valluv) 4 T - i4j Pr. e 4 Pt( /1/40-7-1 ce-raie_ 1341- 2.60611 w�o (NsP11-416 i 471- Noe O s/j 21,V) -FRANK. FRANK CO. 4742 42nd Ave SW #297 Seattle, WA 98116 • Ph: 206579.8160 Project I Scolitekrw--- Date 7-11 II( 00 ZCI ZO I I -oz Prof. Na 2 Design Sheet -.423 Loads: BLC 1, 1 Results for LC 1, 1111111111111 111E111111 11111 A. • IIIIIHIIIIIII__1111111 1 1 . Lim! • •..... • ■ ■ ■1 Nv • ilimm11111111 19E111 11E1 • • • ILA I "liaigniTh ■ t■ IMP ,1I,II,Ij,Al,��i, . W !a P.1M�1,1.,1^R. me �maac �1� Feb 2, 2011 at 9;50 AM 61 r2d Beam: M2 Shape: Material: Length: 18.25 ft I Joint: N2 J Joint: N3 41 .0 �' LC 1: Code Check: 0.814 (bending) Report Based On 97 Sections A k fa ksi 3.86 at O ft V k -3.86 at 18.25 ft 11.355 at 9.125 ft fc ksi .215 at 18.06 ft .4 at 18.25 ft M k -ft - 17.211 at 9.125 ft -.215 at 18.06 ft - 11.355 at 9.125 ft ksi AISC ASD 9th Ed. Cock Check Max Bending Check 0.814 Max Shear Check 0.093 Location 9.125 ft Location 18.25 ft Equation H1 -2 Max Defl Ratio L/466 Compact Fy 50 ksi Out Plane In Plane Fa 4.938 ksi Cm .85 Ft 30 ksi Lb 18.25 ft 18.25 ft Fb 13.95 ksi KL/r 173.895 62.638 Fy 20 ksi Sway No No Cb 1 L Comp Flange 18.25 ft 4 EVAPCO, INC. LE.... c° UNIT COOLING TOWER MODEL # AT- 29-121 - SCALE I DWG. # 4 T309212DRB -ST REV. I DATE 1 11/11/2010 I SERIAL # ' NOTES: 1. (M)- FAN MOTOR LOCATION 2. HEAVIEST SECTION IS UPPER SECTION 3. MPT DENOTES MALE PIPE THREAD FPT DENOTES FEMALE PIPE THREAD Q'1) ACCESS DOOR (M) AOCESS DCOR BFW DENOTES BEVELED FOR WEL ' I 4. +UNIT WEIGHT DOES NOT INCLUD' ACCESSORIES (SEE ACCESSORY D • • I S) 5. MAKE -UP WATER PRESSURE 20 psi MIN [137 kPa), 50 psi MAX [344 kPa [ 25781]/2 VIE 6jt'*+ ii1i� gi = _ = _ x.111 ` I� = = `�` // =���/ 21' -O" / 8 — [ 6401] FACE 1 [543j m ' 51 :e. An J LLTJL -J , A [ ] 841/2 [ 2148 ] -3 4" ] - `. 12' [ 3677 1 4 J 63 [ 1600 ] a ��Ia _ II [ 1600 ] �WAYt���w� ...:....:.:.:.:.:. 60 99 [2527] 1/2 z (sol MPT. IjIIIIIIIIIIIII ....••.. .•.00.4,00 ..•.•. �. ,. �. ,.. .••,•1.•.1.1.1• • •.e••.• 41004.,.x.400 �. •...�.,.;4.,.152 .�.�.•.�.�.�.�. ;'iIiIIFIiIIf1I! 8' -5 1/2" 23 1/8 / [ 587 ] / [ 3787 71/2—' [ 19b] 3/8 8 3 [ 92 5/g ] _ / [ 133] [ 229] —' ..E._. F 7 [ER FPT OVERFLOW 3 Iso7 FPT DRAIN [ 1600 ] s BFW /GVD OUTLET 21'-0" [ 1600 ] [ 2578 J ' [ 10 ] [ 6401 ] >FACEA FACE 1 SHIPPING WEIGHT 9200 Ibs+ [4173] kg+ OPERATING I WEIGHT 16140 Ibs [7321] kg+ HEAVIEST SECTION I WEIGHT 6410 [bs+ [2908] kg+ ] N0. OF SHIPPING SECTIONS 2 • Cooling Tower Data Sheet JCPenney Project JCP Seattle WA #0969 Equipment Reference: Product Type: AT- Cooling Tower Rick Froebe Texas AirSystems, Inc. 2932 West Story Road Irving, TX, 75038, USA 972 - 570-4700 Fax: 9725704207 Selection Criteria Capacity (Tons): 600.00 Capacity (MBH): 9,000.000 Fluid: Water Flow (GPM): 1,800.0 Entering Fluid Temp (F): 95.00 Leaving Fluid Temp (F): 85.00 Wet Bulb (F): 66.00 Date: 11/11/10 Page: 1 IBC Design Criteria Seismic Design Force (g) Velocity Pressure (psf) CTI Certified Selection Qty Model Capacity Percent Capacity (Tons) 1 AT -29 -121 684.00 114.0 All Weights, Dimensions and Technical Data are Shown per Unit # Fans: 2 Overall Length: 21' 0.000" # Fan Motors @ HP: (2) @ 7.50 (460/3/60) Overall Width: 8' 5.500" # Heaters @ kW: (2) @ 7.00 Overall Height 12' 0.750" Air Flow (CFM): 91,800 Inlet Pressure Drop (PSI): 2.8 Operating Weight (Ibs): 15,940 Evaporated Water Rate (gpm): 14.4 Shipping Weight (Ibs): 9,000 Heaviest Section (Ibs): 6,210 Options Selected: IBC Compliant up to 1g Ladder Ladder Extension : 3 foot Sump Sweeper Piping Vibration Switch 304 Stainless Steel Cold Water Basin El. Heaters (OF / -18C ambient) (2) @ 7 kW Fan Motor. Inverter Duty iES Version: June 2010 EVAPCO, INC. eY= c° ' STEEL SUPPORT CONFIGU' ' 1 UNIT' 8.5x21 INDUCED DRAFT TOWERS I DWG. # SLIX0921 -DC 51 CI) iI / 66 1391 ] 66 3/4 "` [ 51 ] C/L OF UNIT LOAD 716 [ 21/ 99 537]8 [ C/L OF MOUNTING [ ] j'--- [ ] [ ] �� [ r [ 1391 ] HOLES — 1 /- UNIT OUTLINE PIP [ 8, 4 [4178 -`' 13/16 [ 21 ] f , 1 (12)0 3/4" [19mm] MOUNTING HOLES - UNIT [ 21/]16 MO PLAN VIEW NOTES: 1. BEAMS SHOULD BE SIZED IN ACCORDANCE WITH AC • 9 • UCTURAL PRACTICE 6. ANCHORING ARRANGEMENT SHOWN HAS A MAXIMUM WIND RATING OF 60 PSF [2.87 )(Pal ON MAXIMUM DEFLECTION OF BEAM UNDER UNIT TO B:4lit:r7. F U 1 ' • ' s • w D 1/2" [13mm]. CASED VERTICAL SURFACES. 2. DEFLECTION MAY BE CALCULATED BY USIN I. 55% OF THE OPERATING WEIG AS 7. THE FACTORY RECOMMENDED STEEL SUPPORT CONFIGURATION IS SHOWN. - A UNIFORM LOAD ON EACH BEAM. SEE CER - • " IGHT. CONSULT THE FACTORY FOR ALTERNATE SUPPORT CONFIGURATIONS. 3. SUPPORT BEAMS AND ANCHOR HARDWARE ARE TO BE FURNISHED BY OTHERS. 8. UNIT SHOULD BE POSITIONED ON STEEL SUCH THAT THE ANCHORING HARDWARE FULLY ANCHOR HARDWARE TO BE ASTM - A325 518" [16mm] BOLT OR EQUIVALENT. PENETRATES THE BEAM'S FLANGE AND CLEARS THE BEAM'S WEB. 4. BEAMS MUST BE LOCATED UNDER THE FULL LENGTH OF THE PAN SECTION. 5. SUPPORTING BEAM SURFACE MUST BE LEVEL DO NOT LEVEL THE UNIT BY PLACING SHIMS BETWEEN THE UNIT MOUNTING FLANGE AND THE SUPPORTING BEAM. WEIGHTS DO NOT USE FOR CONSTRUCTION. REFER TO FACTORY FOR CERTIFIED DIMENSIONS SECTION DATA FAN MOTOR HORSEPOWER APPS Oper. Heaviest Section (Surface) Net Wt. Minimum Sedion Clearance Dimensions MODEL TMA 0" ESP %" ESP 14" ESP MODEL TPA 14" ESP 0" ESP MODEL NO 275B 40 - 100% 10614 4914 100% 10614 4914 6314 x 11714 64500 3408 . 47% 108% 114% 49% 6314 x117% 68000 63% x117% 72000 2 -15 2.15 2-20 6414 12416 131 4914 4208 79% 14016 14614 4914 4408 40 100% 100% 4396 4958 47% 108% 108% 4396 57% u11711 102000 57% x117% 105000 6414 x11714 6414 124% 124% 4314 7915 140% 14016 43% 110000 4-15 4-15 4.15 4-20 4,20 6 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director LARRY MAYOTTE 22745 29TH DR SE, SUITE 100 BOTHELL WA 98021 RE: Permit No. M11 -028 J C PENNEY 1249 SOUTHCENTER MALL TUKW Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 12/13/2011. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 12/13/2011, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File: Permit File No. M11 -028 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 • • P T PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M11 -028 DATE: 02 -25 -11 PROJECT NAME: J C PENNEY SITE ADDRESS: 1249 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENT : auu' l in Ivl g"D' i sion Public Works MA- 3 -1 Ire Prevention Structural Planning Division ❑ Permit Coordinator • DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete DUE DATE: 03-01-11 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 03 -29 -11 Not Approved (attach comments) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 Contractors or Tradespeople Per Friendly Page • General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company JOHNSON CONTROLS INC 4145247765 Attn: Ssc A33 Barb PO BOX 2012 Milwaukee WI 532012012 Out Of State Corporation UBI No. 409000328 Status Active License No. J0HNSC *27205 License Type Construction Contractor Effective Date 9/10/1973 Expiration Date 10/23/2012 Suspend Date Specialty 1 General Specialty 2 Unused Business Owner Information Name Role Effective Date Expiration Date ROELL, STEPHEN A President 11/08/2010 Amount OKARMA, JEROME DENNIS Secretary 11/08/2010 HDG025521390 VOLTOLINA, FRANK A Treasurer 11/08/2010 MCDONALD, ROBERT BRUCE Vice President 11/08/2010 ACE AMERICAN INSURANCE COMPANY KEYES, JAMES H Secretary 01/01/1980 11/08/2010 KENNEDY, JOHN P Secretary 01/01/1980 11/08/2010 OLIVER, WALTER M Secretary 01/01/1980 11/08/2010 WILSON, JAMES F Secretary 01/01/1980 11/08/2010 BASTIANEN, BEN C M Treasurer 01/01/1980 11/08/2010 WILLIAMS, RONALD M Treasurer 01/01/1980 11/08/2010 KILLIAN, WILLIAM P Treasurer 01/01/1980 11/08/2010 LEWIS, JOSEPH W Treasurer 01/01/1980 11/08/2010 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 5 SAFECO INS CO OF AMERICA 2539749 10/01/2001 Until Cancelled $12,000.00 10/23/2001 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 26 Ace American Insurance Company HDG025521390 10/01/2010 10/01/2011 $1,000,000.00 09/30/2010 25 ACE AMERICAN INSURANCE COMPANY HDOG24934056 10/01/2009 10/01/2010 $5,000,000.0011 /12/2009 24 ACE AMERICAN INS CO HDOG23746396 10/01/2008 10/01/2009 $5,000,000.0009 /12/2008 23 ACE AMERICAN INS CO HDOG2373283A 10/01/2007 10/01/2008 $5,000,000.00 09/17/2007 22 ILLINOIS UNION INS CO HDOG1723551 10/01/2005 10/01/2007 $5,000,000.0009 /29/2006 21 ILLINOIS UNION INS CO HD02171124A 10/01/2004 10/01/2005 $5,000,000.00 10/01/2004 https://fortress.wa.gov/lni/bbip/Print.aspx 03/30/2011 r REVISIONS No changes she!! be m t' t' ^ -cope of Work rA40^-‘!t pr c r apps ovc: l r4 `r'' " ",v:la Building Division. t: r : ^svisions will require a new plan submiffal and may include additional plan review fees. Criteria General Structural Notes The following apply unless shown otherwise on the drawings 1. ALL MATERIALS, WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO THE DRAWINGS, SPECIFICATIONS, AND THE INTERNATIONAL BUILDING CODE (2009 EDITION). 2. DESIGN LOADING CRITERIA: RETAIL FLOOR LIVE LOAD (DINING ROOMS AND RESTAURANTS) 100 PSF FLOOR LIVE LOAD (STORES - RETAIL FIRST FLOOR) 100 PSF FLOOR LIVE LOAD (STORES - RETAIL UPPER FLOORS) 75 PSF FLOOR LIVE LOAD (STORES - WHOLESALE) 125 PSF FLOOR CONCENTRATED LOAD (STORES) 1000 LBS ROOF ROOF LIVE LOAD 25 PSF ROOF LIVE LOAD (TENANT ACCESSIBLE) 60 PSF ROOF LIVE LOAD (PUBLIC ACCESSIBLE) 100 PSF MISCELLANEOUS LOADS MECHANICAL UNITS WEIGHTS FURNISHED BY MANUFACTURER ENVIRONMENTAL LOADS SNOW Ce =1.0, Is =1.0, Ct =1. 1, Pg =25 PSF, Pf =20 PSF WIND I w =1.0, GCp i =O. 18, 85 MPH, EXPOSURE "B" EARTHQUAKE ANALYSIS PROCEDURE: NON- STRUCTURAL COMPONENTS SITE CLASS =D, Ss =1.42, Sds =0.95, S1 =0.49, SD1 =0.49, SDC D, Ip =1.0, Ap =2.5 Rp =6.0 3. STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH ARCHITECTURAL DRAWINGS FOR BIDDING AND CONSTRUCTION. ARCHITECTURAL DRAWINGS ARE THE PRIME CONTRACT DRAWINGS. ANY DISCREPANCIES FOUND AMONG THE DRAWINGS, THE SPECIFICATION, THESE GENERAL NOTES AND THE SITE CONDITIONS SHALL BE REPORTED TO THE ARCHITECT, WHO SHALL CORRECT SUCH DISCREPANCY IN WRITING. ANY WORK DONE BY THE GENERAL CONTRACTOR AFTER DISCOVERY OF SUCH DISCREPANCY SHALL BE DONE AT THE GENERAL CONTRACTOR'S RISK. 4. PRIMARY STRUCTURAL ELEMENTS NOT DIMENSIONED ON THE STRUCTURAL PLANS AND DETAILS SHALL BE LOCATED BY THE ARCHITECTURAL PLANS AND DETAILS. VERTICAL DIMENSION CONTROL IS DEFINED BY THE ARCHITECTURAL WALL SECTIONS, BUILDING SECTION, AND PLANS. DETAILING AND SHOP DRAWING PRODUCTION FOR STRUCTURAL ELEMENTS WILL REQUIRE DIMENSIONAL INFORMATION CONTAINED IN BOTH ARCHITECTURAL AND STRUCTURAL DRAWINGS. 5. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND THE METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES REQUIRED TO PERFORM THE CONTRACTORS WORK. THE STRUCTURAL ENGINEER HAS NO OVERALL SUPERVISORY AUTHORITY OR ACTUAL AND /OR DIRECT RESPONSIBILITY FOR THE SPECIFIC WORKING CONDITIONS AT THE SITE AND /OR FOR ANY HAZARDS RESULTING FROM THE ACTIONS OF ANY TRADE CONTRACTOR. THE STRUCTURAL ENGINEER HAS NO DUTY TO INSPECT, SUPERVISE, NOTE, CORRECT, OR REPORT ANY HEALTH OR SAFETY DEFICIENCIES TO THE OWNER, CONTRACTORS, OR OTHER ENTITIES OR PERSONS AT THE PROJECT SITE. 6. CONTRACTOR SHALL PROVIDE TEMPORARY BRACING FOR THE STRUCTURE AND STRUCTURAL COMPONENTS UNTIL ALL FINAL CONNECTIONS HAVE BEEN COMPLETED IN ACCORDANCE WITH THE PLANS. CONFORM TO ASCE 37-02 "DESIGN LOADS ON STRUCTURES DURING CONSTRUCTION ". 7. CONTRACTOR- INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE ARCHITECT AND STRUCTURAL ENGINEER FOR APPROVAL PRIOR TO FABRICATION OR CONSTRUCTION. CHANGES SHOWN ON SHOP DRAWINGS ONLY WILL NOT SATISFY THIS REQUIREMENT. 8. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE NOT SPECIFICALLY INDICATED BUT ARE OF SIMILAR CHARACTER TO DETAILS SHOWN, SIMILAR DETAILS OF CONSTRUCTION SHALL BE USED, SUBJECT TO REVIEW AND APPROVAL BY THE ARCHITECT AND THE STRUCTURAL ENGINEER. ALL TYPICAL AND NOTES SHOWN ON DRAWINGS SHALL APPLY, UNLESS NOTED OTHERWISE. TYPICAL DETAILS MAY NOT NECESSARILY BE INDICATED ON THE PLANS BUT SHALL STILL APPLY AS SHOWN OR DESCRIBED IN THE DETAILS. WHERE TYPICAL DETAILS ARE NOTED ON THE PLANS, THE SPECIFIED TYPICAL DETAIL SHALL BE USED. WHERE NO TYPICAL DETAIL IS NOTED, IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO CHOOSE THE APPROPRIATE TYPICAL DETAIL FROM THOSE PROVIDED. THE CONTRACTOR SHALL SUBMIT ALL PROPOSED ALTERNATE TYPICAL DETAILS TO THOSE PROVIDED WITH RELATED CALCULATIONS TO THE ENGINEER FOR APPROVAL PRIOR TO SHOP DRAWING PRODUCTION AND FIELD USE. I 11 11 11 11 ll (1=) Co Nc. PL) N174. "I AM 17132 P`M\? REVIEWED FOR CODE COMPLIANCE AODDAVFD MAR 21 2011 PL o CityofT ila BUILDING LgInM Renovation 9. DEMOLITION: CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS BEFORE COMMENCING ANY DEMOLITION. SHORING SHALL BE INSTALLED TO SUPPORT EXISTING CONSTRUCTION AS REQUIRED AND IN A MANNER SUITABLE TO THE WORK SEQUENCES. DEMOLITION DEBRIS SHALL NOT BE ALLOWED TO DAMAGE OR OVERLOAD THE EXISTING STRUCTURE. LIMIT CONSTRUCTION LOADING (INCLUDING DEMOLITION DEBRIS) ON EXISTING FLOOR SYSTEMS TO 40 PSF. 10. CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS, MEMBER SIZES, AND CONDITIONS PRIOR TO COMMENCING ANY WORK. ALL DIMENSIONS OF EXISTING CONSTRUCTION SHOWN ON THE DRAWINGS ARE INTENDED AS GUIDELINES ONLY AND MUST BE VERIFIED. Concrete 11. NON- SHRINK GROUT SHALL BE FURNISHED BY AN APPROVED MANUFACTURER AND SHALL BE MIXED AND PLACED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S PUBLISHED RECOMMENDATIONS. GROUT STRENGTH SHALL BE AT LEAST EQUAL TO THE MATERIAL ON WHICH IT IS PLACED (3000 PSI MINIMUM). Steel 12. STRUCTURAL STEEL DESIGN, FABRICATION, AND ERECTION SHALL BE BASED ON: A.AISC 360 AND SECTION 2205.2 OF THE INTERNATIONAL BUILDING CODE. Abossein Engineering MECHANICAL - ELECTRICAL FIRE PROTECTION - ENERGY 2100 112TH AVE. NE BELLEVUE, WA 98004 PH: (425) 462 -9441 FAX: (425) 462 -9451 E -Mail: cservice@abossein.com Website: miabossein,com B. MARCH 18, 2005 AISC CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES AMENDED AS FOLLOWS. 1. AS NOTED IN THE CONTRACT DOCUMENTS. 2. BY THE DELETION OF PARAGRAPH 4.4.1. 3. REVISE REFERENCE FROM "STRUCTURAL DESIGN DRAWINGS" TO "CONTRACT DOCUMENTS" IN PARAGRAPH 3.1. C. SPECIFICATION FOR STRUCTURAL JOINTS USING ASTM A325 OR A490 BOLTS. 13. WIDE FLANGE SHAPES SHALL CONFORM TO ASTM A992, Fy = 50 KSI. OTHER ROLLED SHAPES INCLUDING PLATES, SHALL CONFORM TO ASTM A36, Fy = 36 KSI. STEEL PIPE SHALL CONFORM TO ASTM A -53, TYPE E OR S, GRADE B, Fy = 35 KSI. STRUCTURAL TUBING SHALL CONFORM TO ASTM A500, GRADE B, Fy = 42 KSI (ROUND), Fy = 46 KSI (SQUARE AND RECTANGULAR). CONNECTION BOLTS SHALL CONFORM TO ASTM A307. 14. ARCHITECTURALLY EXPOSED STRUCTURAL STEEL SHALL CONFORM TO SECTION 10 OF THE AISC CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES. 15. ALL A -325N CONNECTION BOLTS NEED ONLY BE TIGHTENED TO A SNUG TIGHT CONDITION, DEFINED AS THE TIGHTNESS THAT EXISTS WHEN ALL PLIES IN A JOINT ARE IN FIRM CONTACT. THIS MAY BE ATTAINED BY A FEW IMPACTS OF AN IMPACT WRENCH OR THE FULL EFFORT OF AN IRONWORKER USING AN ORDINARY SPUD WRENCH. 16. ALL ANCHORS EMBEDDED IN MASONRY OR CONCRETE SHALL BE A307 HEADED BOLTS OR A36 THREADED ROD WITH AN ASTM 563 HEAVY HEX NUT TACK WELDED ON THE EMBEDDED END. 17. ALL WELDING SHALL BE IN CONFORMANCE WITH A. I. S. C. AND A. W. S. STANDARDS AND SHALL BE,PERFORMED BY W.A.B.O. CERTIFIED WELDERS USING E70 XX ELECTRODES. ONLY PREQUALIFIED WELDS (AS DEFINED BY A.W.S.) SHALL BE USED. ALL COMPLETE JOINT PENETRATION GROOVE WELDS SHALL BE MADE WITH A FILLER MATERIAL THAT HAS A MINIMUM CVN TOUGHNESS OF-20-FT-LBS-AT -20-DEGREES_F AND_. 40 FT_ - _LBSJALJ1 _ DEGREES F, AS DETERMINED BY AWS CLASSIFICATION OR MANUFACTURER CERTIFICATION. FILE COPY Permit Plan review approval Is stigeot to ants and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy and is admowiedged: BY City Of 1Ukwila BUILDING DIVISION !_. _.rte .......;..__. FACE OF SUPPORTING MEMBER size per schedule BEAM SIZE PER PLAN SHEAR PLATE SIZE AND BOLTS PER SCHEDULE W/ STD. ROUND HOLES IN PLATE Shear Plate Schedule f LkN. V 1.El1'4 Beam Size No. of Bolts Bolt Size Plate Thickness Weld Size W8, W10 2 3/4"O 1/4" 3/16° W12 3 3/4"0 1/4" 3/16" W14 '3 3/4 "0 1/4" 3/16" W16 4 3/4 "O 1/4" 3/16" W18 5 WO 1/4" 3/16" W21 4 1'10 3/8" 5/16" W24 5 1"O 3/8" 5/16" W27 6 1"0 3/8" 5/16" W30 7 1"0 3 /8" 5/is" BOLT TYPE - A325N, R MATERIAL - A36 ?LAN GAOL /NGt TDWER. )34, 492S N( (14.5 r 71525 CaAvN 660- 3/!. J - - - f-3I s 1 "LB/EUnI4 4 ocJr -- CM J 41r -._. e,'6 orPon! Revisions: A 8 m,A rte.?Lm4 - Cowl Pet A kIL (E) con.... p..rNrH.�_ 570" ep A F 'S *1W" FOR 3/4"0 BOLTS 13/4" FOR 1 "0 BOLTS Vsi &x221 EX►s11NG lG'�if� GONG 1'Lll\1119. it each covaler SEPARATE PERMIT' REQUIRED FOR: - 0 Mechanical Electrical Plumbing as Piping _ City of Tukwila C'i Pi; VI:73 A,- Job No.: 211010 Date: 2/1/11 0001- (4 -law e TLAT or M /NCI l CITYREOPTluveD FEB 25 2011 nrii1-000ag (OF 1) MEN