Loading...
HomeMy WebLinkAboutPermit M11-038 - VULCAN EMPVULCAN EMP 3314 S 116 ST Mi 1 -038 City oftukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: //www.ci.tukwila.wa.us MECHANICAL PERMIT Parcel No.: 1023049011 Address: 3314 S 116 ST TUKW Project Name: VULCAN EMP Permit Number: M11 -038 Issue Date: 04/27/2011 Permit Expires On: 10/24/2011 Owner: Name: APOLLO HOLDINGS LLC Address: 505 5TH AVE S #900 , SEATTLE WA 98104 Contact Person: Name: SHANNON BUCKINGHAM Address: 5108 D ST NW , AUBURN WA 98001 Email: SHANNONB @EMERALDAIRE.COM Phone: 253 872 -5665 Contractor: Name: EMERALD AIRE INC. Phone: 206 872 -5665 Address: 22043 68TH AVENUE SOUTH , KENT, WA 98032 Contractor License No: EMERAAI055BL Expiration Date: 04/01/2013 DESCRIPTION OF WORK: INSTALL (2) 5 -TON SPLIT SYSTEM HEAT PUMPS, (2) UNIT HEATERS, (1) EXHAUST FAN, AND ALL ASSOCIATED DUCTWORK AND GRILLES. Value of Mechanical: 140,000.00 Fees Collected: $1,719.56 Type of Fire Protection: UNKNOWN International Mechanical Code Edition: 2009 Electrical Service Provided by: Permit Center Authorized Signature: Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performanp of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this permit. Signature: Print Name: 6han r1 0(P) This permit shall become null and void if the work is not c menced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -4/10 M11-038 Printed: 04 -27 -2011 • • PERMIT CONDITIONS Permit No. M11 -038 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: Readily accessible access to roof mounted equipment is required. 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 10: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or art approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IMC -4/10 M11-038 Printed: 04 -27 -2011 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.citukwila.wa. uS Mechanical Permit No. Project No. Vic( -o3, (For Grwc L, c only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** Site Address: Tenant Name: EM1P Property Owners Name: Mailing Address: 1 King Co Assessor's Tax No.: k , Suite Number: Floor: New Tenant: Yes 0.. No City State Zip CONTACT PERSON - Who do we contact when your permit is ready to be issued Name: S V\rs\ —60 C. \ 1r1 c':\\(\-(;,1 s Mailing Address: 5' O$ .� �� E -Mail Address: Day Telephone: SU-ac State Zip City Y\ esr r e %a1(C-COI-Fax Number: MECHANICAL CONTRACTOR INFORMATION Company Name: c p", p� Mailing Address: 3\v�S >�� ,.t tt r1 A - 1$(X�� State Zip Contact Person: .ryl ) CIA-)% City (Yl Day Telephone: E -Mail Address: ■CA1 -c1c ,,� Q.ft1�CCQC S(Q. •Cs 1r� Fax Number: a 3— T1 a -S�]c1 Contractor Registration Number: CE `� 1�1C� ��jl Expiration Date: ) I I It ARCHITECT OF RECORD All plans must be wet stamped by Architect of Record Company Name: Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: ENGINEER OF RECORD — All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: Contact Person: City Day Telephone: E -Mail Address: Fax Number: State Zip H: Apptications\Forms- Applications On Line\2009 Applications \I -2009 - Mechanical Permit Application.doc Revised. 1 -2009 bh Page 1 of 2 r • Valuation of Project (contractor's bid price): $ �i ? �,,rn Scope of Work (please provide detailed information): 1,( LII C 4 41 " k Mut -1 Use: Residential: New Commercial: New Replacement Replacement Fuel Type: Electric EV Gas ❑ Other: Indicate type of mechanical work being installed and the quantity below: Unit Type: Qty Unit Type: • Qty Unit Type:.: Qty. Boiler /Comp'resor:' .Qty . Furnace <100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace >100K BTU Evaporator Cooler Diffuser - 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct ' Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater , Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or addition to Heat/Refrig/Cooling System Incinerator — Domestic Other Mechanical Equipment �Q ' - i Air Handling Unit <10,000 CFM Incinerator — Comm/Ind Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWN OR AUTHORIZED AGENT: Signature: Date: Print Name: V k1G -1r' 7r xJ(,�d< Ct►•- .rh Mailing Address: 610% O 5 A) Day Telephone: City c253 7d tj(iS State Zip Date Application Accepted: �`� �V r Date Application Expires: �v�Lr� Staff Initials: I HrlApplications\Fonm- Applications On Line t2009 Applicationsll -2009 - Mechanical Permit Applicationdoc Revised. 1 -2009 bh Page 2 of 2 • City of Tukwila REVISION SUBMITTAL Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Web site: http: / /www.ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: L Ln 1 ( Plan Check/Permit Number: 11 ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Project Address: Contact Person: Summary of Revision: • Phone Number: a5 — 7 f 060' Pro VLCXkl ccO APR 27 2011 CENTER r I 3 ',I ,ir Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Entered in Permits Plus on 1A-1.--1-- ( 1 HA\Applications\rorms- Applications On Line\2010 Applications \7 -2010 - Revision Submittal.doc Created: 8 -13 -2004 Revised: 7 -2010 • City of Tukwila Department of CommuniV Development velo P ment 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov Parcel No.: 1023049011 Address: 3314 S 116 ST TUKW Suite No: Applicant: VULCAN EMP RECEIPT Permit Number: M11 -038 Status: ISSUED Applied Date: 03/24/2011 Issue Date: 04/27/2011 Receipt No.: R11 -01681 Payment Amount: $63.00 Initials: WER Payment Date: 08/04/2011 02:27 PM User ID: 1655 Balance: $0.00 Payee: SHANNON BUCKINGHAM (PHONE) TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 320751 ACCOUNT ITEM LIST: Description 63.00 Account Code Current Pmts MECHANICAL - NONRES 000.322.102.00.00 63.00 Total: $63.00 doe: Receipt -06 Printed: 08 -04 -2011 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.TukwilaWA.aov Parcel No.: 1023049011 Address: 3314 S 116 ST TUKW Suite No: Applicant: EMP VULCAN RECEIPT Permit Number: M11 -038 Status: ISSUED Applied Date: 03/24/2011 Issue Date: 04/27/2011 Receipt No.: R11 -01473 Payment Amount: $63.00 Initials: TLS Payment Date: 07/14/2011 03:33 PM User ID: 1670 Balance: $0.00 Payee: SARAH M BENHERDER TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. ACCOUNT ITEM LIST: Description 63.00 Account Code Current Pmts MECHANICAL - NONRES 000.322.102.00.00 63.00 Total: $63.00 doc: Receipt -06 Printed: 07 -14 -2011 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 1023049011 Address: 3314 S 116 ST TUKW Suite No: Applicant: VULCAN EMP RECEIPT Permit Number: M11 -038 Status: APPROVED Applied Date: 03/24/2011 Issue Date: Receipt No.: R11 -00824 Initials: User ID: WER 1655 Payment Amount: $1,577.50 Payment Date: 04/27/2011 01:43 PM Balance: $0.00 Payee: EMERALD AIRE INC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 1562 1,577.50 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts MECHANICAL - NONRES 000.322.102.00.00 PLAN CHECK - NONRES 000.345.830 Total: $1,577.50 1,375.65 201.85 doc: Receiot -06 Printed: 04 -27 -2011 • City of Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone : 206-431-3670 Fax: 206 -431 -3665 Web site: ht4x//www.ci.tuicwila.wa.us Parcel No.: 1023049011 Address: 3314 S 116 ST TUKW Suite No: Applicant: VULCAN EMP RECEIPT Permit Number: M11 -038 Status: PENDING Applied Date: 03/24/2011 Issue Date: Receipt No.: R11 -00581 Initials: User ID: Payee: WER 1655 Payment Amount: $142.06 Payment Date: 03/24/2011 03:33 PM Balance: $568.25 EMERALD AIRE INC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 1553 142.06 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 142.06 Total: $142.06 doc: Receiot -06 Printed: 03 -24 -2011 4s1 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 p (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 M II- oak Pro a Type f Inspectio (r r c -7s ; J" 1... . 41P/ove4 3froKe / ' /-Q o4ip Address:? ? L 3 3, , Date Called: rr�/�j ,U .1.1N-14: .1_. Special Instructions: �`"J / �`� Date Wanted:. (r /,a.m. P Requester: Pho a Noff __ Approved per applicable codes. ElCorrections required prior to approval. COMMENTS: - (r r c -7s ; J" 1... . 41P/ove4 3froKe / ' /-Q o4ip c) p-r'o,i tt 1 l S 1-.) J c)4J4 rr�/�j ,U .1.1N-14: .1_. W AI , 1 60 M� (eke ri REINSPECTION FEE REQI.JIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit 01 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -367 Permit Inspection Request Line (206) 431 -2451 Pro ec : k CA-V\ l Type /�jf�Inspect�'°n: ► + Addres_s:' l J� I Date Called: .3tvJ (( S/t- ■ ar e S t QJ Special lnstrt ctions: NRequester: /' A Date Wanted: c `.m i Phone No: Approved per applicable codes. a Corrections required prior to approval. COMMENTS: ilU, i 1----e, �(e"� ,A .3tvJ (( S/t- ■ ar e S t QJ 1 A ,/ 0 J r' k 1?. ,) J! f, k \,' . i r \, ii 3e41- A I ,' Inspec or: Date: ri REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. • INSPECTION RECORD' Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION G 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 • Project: D Type e.. pec�ion: ni:lrns.:( / / ! ,, `:(i Date Called: Special Instructions: 3co pS Date Wanted — (r--I/ "- �m� p.m. Requester: Phony oN(0 t4) Approved per applicable codes. Corrections required prior to approval. COMMENTS: A-.9,0)-3 JP 1) Prkk TPSiS 3co pS Insp q, tor: Date: -7- I k-' ❑ REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. _ . INSPECTION RECORD , o34/ Retain a copy with permit _ INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: / _ Type,Qf In ction: ..._.�LI M6 f-ef Ad lie : 1 Go ► . sr Date Called: Special Instructions: a Date �— / l/ m. r S P.m. Requester: Phone 29 4 — 4 /14 3 E i ❑ Approved per applicable codes. El Corrections required prior to approval. COMMENTS: eid( Inspdctor: Dat t (1. n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Bled.. Suite 100. Call to schedule reinspection: • / I o� EMERALD AIRE 5108 D STREET NW; AUBURN, WA 98001 VOICE: (254) 872 -5665 FAX: (253) 872 -5797 s JOB: SUBJECT: � 5 v iP ✓ A o t r i - Wilev &Ka afri/2 — . NOTES: /771 /1' DWG BY PAGE e(tr OFL DATE SCALE. REVIEWEp —F:0R CODE COMPLIANCE APPROVED AUG 0 3 2011 City of Tukwila G DIVISION 4-- _ ,V h) b41 p -S ( UXA) � l U Nth .q // rgeeesc , e_ 5ert-►Via dr• T o/ �,��" yr (J p IIIK J i e)c(ST zmi44piaas i v AI- A C, r .. DA g -a612 Nam► Foie_ 04-C1F 17 A sue' • CITYUK7NLA JUL 2 9 2011 PERMIT CENTER ittd'iON Na �llll- 03� r 4 4ii. AH -2 _i_?i i E. Lim -- REVIEWED FOR CODE COMPLIANCE APPROVED BUILDI 20X20 DUCT Mg UP TO DUCT DOWN THROUGH 16X10 c LIEF HOOD VAULT LID 4L5PCF6M 20x18 ,:; 1.31.E WALL r Fri7g coPY i L_J i 2420 DUCT( W %2'LINERi !I ECONOMIZER i' ©I DAMPERS �1 —� 11'4,11 a 111111 OSA INTAKE HOOD CURB LEVELING & ROOFING BY OTHERS ^o RLi„ CD4CRE1t sE_AtE TNrC .2•110UT Vka0C EXPOSED SPIRAL J!ID ST•`•CI1:;, Roov, DUCTWORK ^" -TLR ia..1 2000 0 SIMILAR A,:-PROVED 20X20 DUCT ! EC �—W ✓2 --- i i X71 20X20 DI CT —=_ WI FOR LEAD LAG SWTICHING 1 .— &P 20X20 50F RETURN GRILLE :r.A TE INTER MOTORIZED DAMPER W /OCCUPANCY SE POWER B 8' THROUGH CK EN OR EC UP OF q INTAKE HOOD /ECONOMIZER DETAIL Iw 20•A S -K -cNED OPENINCI'ii RELIEF HOOD Y(- UP THROUGH ROOF CURB LEVELING & ROOFING BY OTHERS A ila (VISION Plan reviiew$p . esu tQir of anri o"' s _ A3' pVaI of construction dominants does not aufirria thc v!o! lion of an a node or ordinance. Ret pt approved Field ,opy and pions is acnowledged: 1 -- Chip -- crtrwo�� u+ ,----4 2- 9-29- 1 _:_.-_:_- .. ' ..._u_ - -M R ?KLCIEF"DAMPER- -^-#-^ !MODULATE V/ ECONOMIZER OPERATION Tr 4' EVENT UP THROUGH ROOF — 20X20 50F RETURN GRILLE 1 ELIEF HOOD DETAIL - RE "IS1ONS No changes shall bo rn to th^ ^>^ooe of work without prier apt.: oar- I c: Tukwila Building Division NOTE: Revisions will require a new plan submit!c t and may include additional plan revisw lees. j 1 TIN LEVEL HVAC PLAN q � I•b` C: \User.\grenbn\DDDUments \Job VDUM \20 —0 —24 EYP Vault Prelim Permit \CXR— HDEOrg 2 IPIDT 2AIE 3/15120 1 1 Elms.. DEVELOPMENT DRAWING ElCOORDINATION 3.9.11 ▪ PERMIT ❑ CONSTRUCTION ❑ AS BUILT EMERALD AIRE, INC. z U U 1- FLOOR PLAN Scut AS NOIED M1 a01igipNS scope shallbea eto the alof No changes Without prior Division. °� Tukwila Building D vis plan submittal Ions Will require a cev►ew lees' N� dmay include adaional plan an Structural Calculations Vulcan EMP Vault Mechanical Support Structure Review Tukwila, Washington REVIEWED FOR CODE COMPLIANCE APPROVED JUL 12 2011 iia ISION City of BUILDING FILE COPY Pent* No. M\.V 1 Plan review approval is subject to errors and omission. Approval of construction documents does not authoriz the violation of any adopted code or ordinance. Rccei of approved Fief • •py = cations is admowledg. By Date: City Of Ttakwila BUILDING DIVISION SEPARATE PERMIT REQUIRED FOR: Mechanical Electrical Plumbing Gas Pipes BUiv GYDIVISION Magnusson Klemencic Associates 1301 5th Avenue, Suite 3200 Seattle, WA 98101 July 8, 2011 CITY OF TUKWILA JUL 0 8 2011 PERMIT CENTER 1• RVISION NO. _ M1kOSZ Design Sheet MAGNUSSON KLEMENCIC ASSOCIATES ■ Structural + Civil Engineer PROJECT TOIL w (-4 WARE Hc05 - VuL A! O1'? VAU%T SHEET LOCATION CLIENT DATE BY "Att.„, I"IG- Ut�ureAL SuPPOR-r STRUctoR,e I26VIGW CAGC1Gt,ATTOVS . THE CAL COLATro'1S ATTACHED ?Rota DE ft Review Of TR - F rs7wb Tv/0w11,A \A-ARC 1-IWSE j(1.0C7uRE PGRt:705 Br 12-ac 12-acr TRUSSES, At* 60 Mtn/ r t. Vie7GHT riF 48o ft. fort u»J /Ts w?T*I 4 007( ON 714-E RoCF pt:Rt•zvs SIZE spcaN To NAY& To , DACtATE CAffier TY P I h7TACHED st4f t2 f —HF i -ODT ilea At- L-&AO liCW6vt2, P 2 SFKws 'JFrI�T /FE 7+NGr[f/tSEp t.ci4 A cto -rife TRuSsE-S aF ;S, ; r Nett, L) 7tf Till THE rat irtAluGE oP THEIR 17E-C.7-60 - Thera rcn4s p. 3 s cs rN a DESTAN cts: SLEC i'E{'z DE M4 ro TRAN5FcR ykie 6►t,AV7TY k 5c-is t oAos ,F2cM role Wu/ Meal A NY CA L. GPI T Tel Toe t-At1.6e- Truitt SUprort.7 . Design Sheet MAGNUSSON KLEMENCIC ASSOCIATES • Structural + Civil Engineers PROJECT TVpw-' -H E"Y7S?706 Q.Pof CAP /G =Ty LUCCI( LOCATION CLIENT DATE SHEET y BY F'k'lST7,11G E2 OF PURL ?N C RAG7?Y_ 046a Fp(Z. 1V6 W MEL EE () &x L C_ i u u� 1 S �3 5 - AK,fr 27/,k (.(Sk 4 F10'441;1= h "3o = l(00 psi (f) puolos Do ,H3 0%4.4 -4/3 =160 ?v -rAL GGAO M 5coa- f+ M ; 32 243 Vz8b# X av 0E0,3$ o fie pf 'f 3pti -ff = g8� SPAUeO TO r(245ES. Nor I4AvE AOAQuATE MOMEuT GAAAL_'TY, Iro T V = t Fo" . 604 7 36o ✓ Design Sheet MAGNUSSON KLEMENCIC 1 ASSOCIATES • Structural + Civil Engineers PROJECT SHEET Z/ LOCATION CLIENT DATE BY C1.16cit ADD;T7com. L.CAc aF ac 4 TRusSES. OV62 THE 1LooF TRUSSCS Nl xa 70 ' SPA r' 0%* R. TN C ►J6W VAULT w/ A nu- (3urimy w20rW of 16' TILE NEW MEcN (AuT TU tee. Age TN F CTGRE D LOO D Ir3Y. 16'x 10' (I.z C[0rsf) t I.GCz5 F +) = 5fs. v4 it E- cc420.6M-r `c40 1,Zx4ao c— APDEto 576 71V CI A-56 7S 1. d /o 644 7cK TS VEu 117TN7N TM6 Te1ERAA►ct c# nf E TrluS5E.5 0E57GN. MERE RILE TilE TRvss6s CAu SvppcR -T Th'e ADWTatigt AA Cal ANTCAL LCA 13 rr /4 5L(96 19. BEA 1.1 ZS DESTGNED re, SP' 1A) rNE [GAP To Tfi E41 Design Sheet MAGNUSSON ' KLEMENCIC ASSOCIATES • Strudural + Cv7 Engineers PROJECT TI .12 C41413 CAI (A1.11 SUpToftI 065160. SIIEER ;./ JOCATTOB CLIENT OATS 6/M01 BY -Dvt. T ON F = o, Y aP s,� Wp P RP P c .'t (2,$)Ci) lawn) 3 \ _ 6 ` J 0HEu4- qX tZ 51,‘E964- empis alto y ►Z it - +'h 144-6 6 .(' = ISC� ((q6 Screw) 2-'e -vvY 14rf0 d" XIZ/� & LW (10as?oo ). h b 0.32��L) Iz Z 0t (4)01) tzZ) 6lo,ny oZ s /hi_ 04A'X 12nSycwt . STRLSS ). Sebes; 0,431• r ) k 3 I ,.L I.1 Fv y Cr) C( xfr )icp t;O ps: �L ID? NG swepot. AR•E ACL6?TABL e i3l( 7NS?eL?7f •i f tA6502(t, 320 4 \AP p ek W1= V L 6.5c (- = 3�S # - 3? Y/,6 7 6c4. 1.46 SCOW cawN . A N t .7N EMI &p teGr'V Design Sheet MAGNUSSON KLEMENC1C ASSOCIATES • Structural +Civil Engineers PROJECT SHEET LOCATION CLIENT DATE BY CE)_7RusS 4- (E) truss Design Sheet MAGNUSSON KLEMENCIC ASSOCIATES Structural + Civil Engineers PROJECT SHEET LOCATION CLIENT DATE BY ff _ 'Q, Es of soce6it Yt X437 THRO- a WI NEW XI2 SLECK 13E/iYy St c, xvw in — .T,. 1 '4 C4 Roar Spot TiRtg, '/z `4 LA& 5,11.E td %v/ 3" IM ?N EMIp. Z- TTZ USS TOP C (1 R p, or n2uct bP (KW, • 2" SC-C770N ERMIT COORD COP PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M11 -038 PROJECT NAME: VULAN EMP DATE: 07/29/11 SITE ADDRESS: 3314 S 116 ST Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # X Revision # 2 after Permit Issued DEPARTMENTS: B i ingfviselllon Public Works 0 Fire Pr Oention Structural Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete DUE DATE: 08/02/11 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required n No further Review Required NI REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 08/30/11 Approved Approved with Conditions n Not Approved (attach comments) Notation: REVIEWER'S INITIALS: n DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 °PERMIT COORD COO PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M11 -038 PROJECT NAME: EMP DATE: 07/08/11 SITE ADDRESS: 3314 S 116 ST Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # X Revision # 1 after Permit Issued DEPARTMENTS: Bu 9 ildin - Division Public Works Fire Prevention ❑ Structural Planning Division Permit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete ❑ DUE DATE: 07/12/11 Not Applicable Comments: Permit Center Use:Only. INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 08 /09 /11 Approved Approved with Conditions Ti Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit'Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 • PE ; ` WtIM�`� .�. PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M11 -038 PROJECT NAME: VULCAN EMP SITE ADDRESS: 3314 S 116 ST X Original Plan Submittal Response to Correction Letter # DATE: 03 -24 -11 Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: =LB • • Division Public Works Ire Prevent on -i111--t1 Structural ❑ Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete ❑ DUE DATE: 03 -29 -11 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route Structural Review Required No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 04-26-11 Not Approved (attach comments) n DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 PROJECT NAME: G V SITE ADDRESS: PERMIT NO ORIGINAL ISSUE DATE: REVISION LOG 01-117-1 tt REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS STAFF INI • S 11Fr! Minn 01 21 1 k Summary of Revision: Gj�y (� tAvh' 6 (-g? S 1'p� V\ I { L, — w Q�1 1rk 1 , V\CD V \ 44\0 AAAS n r P L4 1 Received by: Shamin Sham Ti x.k in a Mr\ REVISION NO. DATE RECEIVED STAFF INITIALS STAFF INITIALS ILITMI \DATA WC ISSUED DATE SMIMI STAFF INI • S 11Fr! Minn I Summary of Revision: Summary of Revision: pKOO IM? ;- Received by: t 5-Ad/ (,j `j D/f.. (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) • City of Tukwila Steven M Mullet, Mayor Department of Community Development 6300 Southcenter Boulevard, Suite # 100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: //www.ci.tukwila.wa.us Steve Lancaster, Director RECEIVED CITY OF TUKWILA IJUL 29 2011 EMIT CEN wf•'~ Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fay etc. Date: n 2- t t 1 Plan ChecWPermit Number: M 11 _( JC ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # Er Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: FANA VJ Project Address: 3N LA � ars- �k Contact Person: Sha fin( T UC Irv- {i�(I, M Phone Number: �53-�S 1� SLP (o Summary of Revision: (', (i4.. •litre. Sr 'E \CO (Q (QAA til7 l)C Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: / Z Qf Entered in Permits Plus on lepplic ations\%anu- applications on line%revision submittal meat ii• 11.11-,nna • 41! City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Web site: http: / /www.ci.tukwila.wa.us REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: ts Plan Check/Permit Number: rn o ?- ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # U Revision # \ after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: P- lo air) Project Address: 331 S 11( ' Contact Person: ha n p nln ?)c y,k,ll V (Utz Phone Number: OS 2)- Vr-D L;(.0 Summary of Revision: CRVRo�L4 JUL 0 8 2071 '"ERMR CENTER lk 1■411iSui.. :1.J . _ k __ i d ._.1 Ill 1.. Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Entered in Permits Plus on 0 1ApplicationsWozms- Applications On Line \2010 Applications \7 -2010 - Revision Submittal.doc +• Created: 8 -13 -2004 Revised: 7 -2010 Contractors or Tradespeople P tter Friendly Page • General /Specialty Contractor A business registered as a construction contractor with LEI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name EMERALD AIRE INC UBI No. 600591552 Phone 2538725665 Status Active Address 5108 D Street Nw License No. EMERAAI055BL Suite /Apt. License Type Construction Contractor City Auburn Effective Date 1/13/1995 State WA Expiration Date 4/1/2013 Zip 98001 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status SOUNDA11580W SOUND AIR INC Construction Contractor General Unused 9/16/1985 8/15/1995 Archived Business Owner Information Name Role Effective Date Expiration Date HAPPE, DOUGLAS A President 01/01/2000 Bond Amount RIDGE, JOHN PATRICK Vice President 01/01/2000 1977929 RICHARDS, RON Secretary 01/13/1995 06/01/2000 TREMAINE, DAVIS WRIGHT Agent 01/13/1995 12/31/1999 DUPUIS - FRICKE, LINDA President 01/13/1995 12/31/1999 HAPPE, DOUGLASA President 01/13/1995 12/31/1999 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 4 THE HANOVER INSURANCE COMPANY 1977929 01/01/2011 Until Cancelled $12,000.00 01/06/2011 3 INS CO OF THE WEST 1352839 10/18/2001 Until Cancelled 01/01/2011 $12,000.0003/29 /2002 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 16 Continental Western Ins Co CWP2434476 04/01/2011 04/01/2012 $1,000,000.00 03/08/2011 15 Continental Western Ins Co CWP2434476 04/01/2010 04/01/2011 $1,000,000.00 03/29/2010 14 Continental Western Ins Co CWP2434476 04/01/2009 04/01/2010 $1,000,000.0003 /20/2009 13 CONTINENTAL WESTERN INS CO CWP2434476 04/01/2008 04/01/2009 $1,000,000.0003 /18/2008 12 CONTINENTAL WESTERN INS CWP2434476 04/01/2007 04/01/2008 $1,000,000.00 03/09/2007 11 CONTINENTAL WESTERN INS CWP2434476 04/01/2006 04/01/2007 $1,000,000.00 03/16/2006 https://fortress.wa.gov/lni/bbip/Print.aspx 04/27/2011 PCJECT LOCATIO\ 3314 SOUTH 116TH STREET TUKW ILA, WA PROJECT :ESCRIPTIO\ TWO 5 -TON LIEBERT UNITS WITH LEAD /LAG CONTROL, SPLIT SYSTEM HEAT PUMP, TWO UNIT HEATERS AND VENT FAN, COMMISSIONING AND BALANCING PER PLAN. V C CO \TRACTOR EMERALD AIRE, INC. 5108 D STREET NW AUBURN, WA 98001 PROJECT MANAGER VD ICE: ( 253) 872 -5665 FAX: ( 253) 872 -5797 c \ERAL CO \TRACTOR WILCDX CONSTRUCTION 234 5TH AVE S EDMONDS, WA 98020 CONTACT PAUL CARTER VOICE: ( 425) 774 -4185 FAX: ( 425) 774 -4187 W. Si E. C. \CITES THERMOSTATS SHALL BE INTERLOCKED TO PREVENT SIMULTANEOUS HEATING AND COOLING PER WSEC 1422. GENERAL CONTRACTOR TO PROVIDE ACCESS TO FIRE AND /OR COMBINATION FIRE /SMOKE DAMPERS. INSULATE REFRIGERANT PIPING PER SEC, TABLE 14 -6. SEAL DUCTWORK PER SEC 1414.1 INSULATE DUCTWORK PER SEC TABLE 14 -5. COMMISSIONING PER SEC SECTION ,t t ;2 c,°t- c'J (5 E C - . r .... V P Th V PORAR VI CI \TY MAP PERMIT v '.RED FOR: w., Ey.± : Y�ChaniCal Ciectricat Plumbing Gks Piping of Tukwila t,; . '). DIVISION SEQUENCE OF OPERATION THE VAULT IS SERVED BY (2) LIEBERT SPLIT SYSTEMS AH -1, AH -2 1, TEMPERATURE AND HUMIDITY CONTROL FOR AH -1 AND AH -2 IS PERFORMED VIA THE FACTORY MOUNTED CONTROLS, THE UNITS HAVE BOTH HUMIDIFICATION AND DEHUMIDIFICATION CAPABILITIES, THE UNIT SETPOINTS ARE AS FOLLOWS: -SPACE TEMP 70F (ADJ) - HUMIDITY 50% (ADJ) 2. LEAD /LAG /BACKUP CONTROL: - AH -1 AND AH -2 ARE CONTROLLED BY A LIEBERT CONTROL PANEL. UPON DETECTION OF A LEAD UNIT FAILURE THE LAG UNIT IS AUTOMATICALLY TURNED ON. THE LEAD UNIT IS ROTATED EVERY 7 DAYS TO EQUALIZE RUNTIME, OR A DURATION SPECIFIED BY LIEBERT, - MOTORIZED DAMPERS ARE CYCLED ACCORDINGLY TO LEAD LAG CONTROL - ECONOMIZER CONTROL SHALL BE THROUGH SEIMENS CONTROL LOGIC 3. AH -1 & AH -2 ARE TO BE MONITORED BY THE BAS VIA A MODBUS COMMUNICATION CARD. THE FOLLOWING ALARMS WILL NOTIFY THE OPERATOR: - AH -1 AND AH -2 COMMUNICATION LOSS FOR 3 MINUTES, - SPACE TEMP (VIA SIEMENS SENSOR): HIGH = 74F LOW = 66F - SPACE HUMIDITY (VIA SIEMENS SENSORS): HIGH = 60% LOW = 40% REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. HVAC �RAWI \G <EY N E•CK SI TYPE CFM —I — 1 E N CFM E GRD IDENTIFIER II SIDE WALL GRILL 0 0 r \e..4 AHU -1 SUPPLY GRILLE THERMAFUSER RETURN AIR GRILLE EXHAUST GRILLE EXHAUST FAN EQUIPMENT TAG Q T -STAY L/V WIRE DUCT RUN ELBOW P d [0, ---L EDU FD♦ :F3 SDI SD P a SFD r SFD O 1- VFD REDUCER SIDE TAPS 90 ELBOW W/ TURNING VANES F-REVItWEDF-INT /C ODE COMPLIANCE APPROVED APR 21 2 f l AAr City ° 'la tY o ILDINS incou FLEXIBLE DUCT MANUAL ' DAMPER FIRE DAMPER SMOKE DAMPER SMOKE /FIRE DAMPER MOTORIZED DAMPER BACKDRAFT DAMPER VARIABLE VOLUME /TEMPETURE VARIABLE FREQUENCY DRIVE ELECTRIC SPLIT SYSTEM UNITS — INDOOR TAG MANUF. MODEL AREA SERVED HEATING SOURCE MBH /(KW) COOLING TONS MBH CFM @S. P. MIN OSA ELECTRICAL VOLTS PH FLA WSA(MCA) OPD WT CONTRL REMARKS. AH -1 LIEBERT MMD6OE VAULT AH -2 LIEBERT MMD6OE VAULT FC -1 MITSUBISHI PEAR —A30AA INTAKE NOTES: CONDENSATE REMOVAL REQUIRED ON ALL UNITS, BY PLUMBER OUTDOOR UNITS TAG MFR, CU -1 LIEBERT CU -2 LIEBERT HP -1 MITSUBISHI MODEL PFH067A —H PFH067A —H PUZ— A3ONHA4 ELEC ELEC HP (16.5) (16, 5) 32 5 61, 2 5 61. 2 2. 5 30 2500 @, 5 400 2500 @, 5 400 740@ , 4 150 460 3 26 32.5 35 460 3 26 32, 5 35 208 1 2. 73 (2. 7) N/A 498 498 73 TONS SEER VOLTS 5 N/A 460 5 N/A 460 2.5 15,5 208 PH FLA WSA( MCA) ODP 3 :11,7 14,2 20 3 11.7 14.2 20 1 -- (25) 40 WT. 351 351 185 UNITS SERVED AH -1 AH -1 FC -1 REMARKS 7DAY PWR FROM HP -1 UNIT BY EC NO ECONOMIZER PER WSEC 1433 EXCEPTION 1, EXHAUST FANS TAG MANUF. MODEL AREA SERVED CFM @ S, P. H, P, RPM ELECTRICAL VOLTS PH MCA WT. dBA CONTROL REMARKS FILE COPY Plan review approval Is subject to errors and omleslons. Approval of constnx tlon documents does not authorize the violation of an A : 0 ' . = code or ordinance. Receipt of approved Field: ' . . , Cordiens Is admowledged: By .Ilul►. Oft 102 City Of ltikwila Mat* DIVISION EF -1 COOK 70C10DH CRATE STORAGE 100 @ 0,1' 1/25 1050 120 1 15 2, 1 SNS CUNT FAN TO RUN CONTINUOUS RECEIVED MAR 241011 PERMIT CENTER UNIT HEATERS TAG UH -1 UH -2 MANUF, REZNOR REZNOR MODEL UDAP -30 UDAP -30 AREA SERVED INTAKE CRATE STORAGE CFM 456 456 HEATING SOURCE MBH AFUE NAT GAS 30 82% NAT GAS 30 82% ELECTRICAL VOLTS PH FLA 120 1 1, 9 120 1 1, 9 WT, 115 115 CONTROL FREEZE STAT FREEZE STAT REMARKS BVENT THROUGH ROOF VERIFY SIZE (24V CONTROL) BVENT THROUGH ROOF VERIFY SIZE (24V CONTROL) Ml1 -038 EXPUIES 2/17/!Z C:\ Users \arantm \Documents \Jobs \EMP Vault \2011 -02 -24 Vulcan EMP Vault Prelim Permit \CXR— HDE_clwa PLOT DATE 3/15/2011 DESIGN DEVELOPMENT DRAWING . COORDINATION 3.9.1 1 ❑ PERMIT CONSTRUCTION AS BUILT a_ LJ uJ J F- EMERALD AIRE, F- LJJ U DRAWN BY: TITLE SHEET SCALE: 1 /4" = 1' -0" V 0 i D SPIRAL DUCTWORK 300RS 16X10 415 CFM ( TYP 6) DUCT ELEVATI ❑N 1/8' = 1' -0' 20X20 DUCT W/2 "LINER ECONOMIZER DAMPERS 6 OSA INTAKE HOOD CURB LEVELING & ROOFING BY OTHERS 20X20 DUCT W /2" L --INER ECI 20X20 DUET OR LEAD LAG SWTICHING 20X20 50F RETURN GRILLE INTAKE H❑ ❑D /EC ❑N❑MIZER DETAIL Ml /1/4' = 1' -0' RELIEF HOOD CURB LEVELING & ROOFING BY OTHERS EL.TTF� IA•t4 E-R^ ....._ _ _. MODULATE W/ ECONOMIZER OPERATION DRAIN 6 L OF CON \IEC PIPE: INTA 20 D TO R E_.......H 20X20 DUCT UP TO 300RS R.. LIEF HOOD UCT DOWN THROUGH 16X10 _._ AULT LID 415 CFM ( TYP 6) --r VAPOR RETARDA T CONCRETE E SEALE' .I.FIROUGHOU..f.. VAULT. EXPOSED SPIRAL AM) SAGIUG ROOv, DUCTWORK K O S 1 E R V A I' - - -1 2000 OR SIv1ILAR AT' 'ROPED - )RODUCT 10'......x„ TAI....I... REMOVABI_.F WALL AREA FOR FUTURE ROLL -UP DOOR REVIEWED FOR CODE COMPLIANCE APPROVED APR 21 211 City of Tukwila BUILDING DIVISION 12M o 440 CFM ( TYP 2) FFICE 'EMAIN CRATE STORAGE: 204 l INTER MOTORIZED DAMPER W /OCCUPANCY SE POWER B 8" THROUGH OCK PEN SOR EC UP OOF 20X10 ❑PENIN UP THROUGH ROOF ENCLOSE EXISTING DOWNSPOUTS. - ROVIDE ACCESS PNI.._S AS \IECESSARY 4" BVENT UP THROUGH ROOF IREVISIONS DESCRIPTION DATE PLOT DATE 3/15/2011 ❑ DESIGN DEVELOPMENT DRAWING • COORDINATION 3.9.11 ❑ PERMIT CONSTRUCTION AS BUILT Ld J F- E EMERALD AIRE, INC. DRAWN BY: RECEIVED MAR 24 2011 PERMIT CENTER MAIN LEVEL HVAC PLAN EW CONCRETE 1/8' = 1' -0' 3698 r.\ I Icorc\ nrnnfm\ Mews' imcn+c \.Inhc\ DAAD \ /ni.l+ \')(11 'I _llrl_')d WI ilnnn rkAD \ /nn.l+ DrelPm Der.,,; +\ /`VD_LIf1C At." FLOOR PLAN SCALE: AS NOTED V 1 C 1 A A301 A302 INTAKE HOOD CU -2 CU -1 EXTENTS OF TENANT ...1MPROVDENT, BELOW UNITS ON SLEEPERS BY GC SECURITY GRILLE, 1YR AT 3 LOCATIONS EE -1 RELIEF HOOD -\\ / Ty r) A605 8 "0 NTAKE MAINTAIN 1OF FROM EX AUST 4" BVENT HP- UNIT ON SLEEPERS BY GC A 1 ■ A302,) REVIEWED FORCE ! CODE COMPLIANCE. An nclOVED City of Tukwila o t RECEIVED MAR 24 2011 PERMIT CENTER U) z a- DESCRIPTION I I DATE PLOT DATE 3/15/2011 ❑ DESIGN DEVELOPMENT DRAWING ■ COORDINATION 3.9.1 1 ❑ PERMIT ❑ CONSTRUCTION AS BUILT U z EMERALD AIRE, F- z w J U CD DRAWN BY: ROOF PLAN SCALE: 1 SS/OIYALG EXPIRES 2J17 /IL I C:\ Users \arantm \Documents \Jobs \EMP Vault \201 1 -02 -24 Vulcan EMP Vault Prelim Permit \CXR— HDE_dwa /8" = 1' -0" V2