Loading...
HomeMy WebLinkAboutPermit M11-050 - BOEING #14-01 C STOREBOEING #14-01 8701 EAST MARGINAL wys M11-050 Parcel No.: Address: City oftukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov MECHANICAL PERMIT 0007400033 8701 EAST MARGINAL WY S TUKW Project Name: BOEING #14 -01 C STORE Permit Number: M11 -050 Issue Date: 05/24/2011 Permit Expires On: 11/20/2011 Owner: Name: Address: Contact Person: Name: Address: Email: Contractor: Name: Address: BOEING COMPANY THE PROPERTY TAX DEPT , PO BOX 3707 M/C 20 -00 98124 ALECSIS SMITH 4600 S 134 PL , SEATTLE WA 98168 ALECSISS @HO LADAYPARKS. C OM Phone: 206 835 -8287 HOLADAY PARKS, INC. Phone: 206 248 -9700 PO BOX 69208 , SEATTLE, WA 98188 Contractor License No: HOLADPI379NO Expiration Date: 09/03/2011 DESCRIPTION OF WORK: TENANT IMPROVEMENT FOR CAFE/SERVERY AND NEW SHOWER ROOMS. ADD (3) SPLIT SYSTEM A/C UNITS, MISCELLANEOUS DUCTWORK REVISIONS, AND (2) NEW EXHAUST FANS. Value of Mechanical: 110,000.00 Type of Fire Protection: SPRINKLERS /AFA Electrical Service Provided by: Permit Center Authorized Signature: Fees Collected: $1,412.06 International Mechanical Code Edition: 2009 Date: I I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this permit. Signature: Print Name: Q &. QX This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Date: S'' 11 doc: IMC -4/10 M11-050 Printed: 05 -24 -2011 • PERMIT CONDITIONS Permit No. M11 -050 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IMC -4/10 M11-050 Printed: 05 -24 -2011 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto://wwwci.tukwila.wa.us Building Permit No. Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No. Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION p j (� /� j� ( King Co Assessor's Tax No.: 0 00 Site Address: ©t \ `-� - " `'�' V l ACA \Aot't( S Suite Number: Tenant Name: �j0 el i1 /4-0/ c—J.S ►-2- New Tenant: Property Owners Name: —.Z' l J-e ill CD I'YI p GL 11 Mailing Address: 1/0 u rC 3'7 o 1 1 t f City +600 33 l� Yes Floor: state Zip CONTACT PERSON — contact when your permit is ready to b issued Name: Mailing Address: pte iS Svttt� ti60 o S, h `i PI E -Mail Address: 41 C C.- S t S S@ 110Lkor t t � rt. Day Telephone: 706 S S 2 �� hit v'k 1216 Si state Zip City Fax Number: GENERAL CONTRACTOR INFORMATION (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: Mailing Address: City Day Telephone: Fax Number: Expiration Date: Contact Person: E -Mail Address: Contractor Registration Number: State Zip ARCHITECT OF RECORD — All plans mu be stamped by Architect of Record Company Name: Mailing Address: City Day Telephone: Fax Number: Contact Person: E -Mail Address: State Zip ENGINEER OF RECORD — All plans must be stamped by Engineer of Record Company Name: Mailing Address: City Day Telephone: Fax Number: Contact Person: E -Mail Address: H:\Applications\Fonns- Applications On Line \2010 Applications \7 -2010 - Permit Application.doc Revised: 7 -2010 bh State Zip Page 1 of 6 MECHANICAL PERMIT INFORMATION - 206- 431 -3670 MECHANICAL CONT Company Name: Mailing Address: Contact Person: E -Mail Address CTOR INFORMATION kktiCi1 -Vat -V6 V C- 1+600 s 131- el CE w 99M II State _ zi^p l P c5 l S i Day Telephone: s 6 s 3 S $ Z T .-- City QGSLSS e Iit.0 a6QaI'nactc$,civvi Fax Number: 7/6 6 Tit I V 6 Contractor Registration Number: A b' 3 Expiration Date: 3 l 14 (( Valuation of Mechanical work (contractor's bid price): $ ` t 0, 00 064 Scope of Work (please provide detailed information): 1--Q Tvig ►-J Ve-14-42-0- cA s vv4- fi to _AA) S1/1QV v Y176\44. - /14-1- �3 ) 5I l' Use: Residential: New .... ❑ Commercial: New .... Replacement .... ❑ Replacement .... ❑ Fuel Type: Electric ❑ Gas .... Other: Indicate type of mechanical work being installed and the quantity below: Unit Type: Qty Unit Type: Qty , Unit Type: Qty Boiler /Compressor: Qty Furnace<100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace >100K BTU Evaporator Cooler Diffuser 10 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 3 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig /Cooling System Incinerator - Domestic Other Mechanical Equipment r 44,1 0 �y' 1 514 S A-C-- 3 Air Handling Unit <10,000 CFM Incinerator — Comm/Ind H:\Applications\Forms- Applications On Line \2010 Applications \7 -2010 - Permit Application.doc Revised: 7 -2010 bh Page 4 of 6 PERIVIIT,>APPI ICATION ''NOTES - Applicable: to all:permits in tliis application ..'14', i<Ad �:_ : }: -�_. _ :. �(Yi }tr'i. i$k•:' .. ':1:I:'t:�: \�•J!i:f .:�i v :p _i ... !'¢ Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWN Signature: Print Name: Mailing Address: L+( 00 5,13Yt -'1I IDate Application Accepted: Date: Day Te hone: ( i CO 3 +( � WA- 98/ City Date Application Expires: ti O State Zip H: Appfications\Fonns- Applications On Line \2010 Applications \7 -2010 - Permit Application.doc Revised: 7 -2010 bh Staff Initials: .{ Page 6 of 6 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.TukwilaWA4ov RECEIPT Parcel No.: 0007400033 Permit Number: M11 -050 Address: 8701 EAST MARGINAL WY S TUKW Status: APPROVED Suite No: Applied Date: 04/27/2011 Applicant: BOEING #14 -01 C STORE Issue Date: Receipt No.: R11 -01053 Payment Amount: $1,129.65 Initials: WER Payment Date: 05/24/2011 11:45 AM User ID: 1655 Balance: $0.00 Payee: HOLADAY PARKS INC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 183300 1,129.65 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts MECHANICAL - NONRES 000.322.102.00.00 1,129.65 Total: $1,129.65 doc: Receiot -06 Printed: 05 -24 -2011 Cif! of Tukwila, Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206-431-3665 Web site: http://www.ci.tukwila.wa.us SET RECEIPT RECEIPT NO: R11 -00833 Initials: JEM User ID: 1165 Payee: HOLADAY- PARKS, INC. Payment Date: 04/27/2011 Total Payment: 375.66 SET ID: S000001498 SET TRANSACTIONS: Set Member Amount 282.41 PG11 -065 93.25 TOTAL: 282.41 SET NAME: Tmp set/Initialized Activities TRANSACTION LIST: Type Method Description Amount Payment Check 182958 ACCOUNT ITEM LIST: Description TOTAL: 375.66 375.66 Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 TOTAL: 375.66 375.66 INSPECTION NO. INSPECTION RECORD . h . Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Projeu: k 4 14— ok Type of 1A e op �1 /A�.1� • �� Address: �/ F<I E• 4/�%6.AJ4L. Date Called: . Special Instf uctions: Date Wanted: —? _— --1�I. .a.m: Requester: Phone No: Approved per applicable codes. El Corrections required prior to approval. COMMENTS: AAA C) r r PA--; 3/1S AAA tat /ut ( Co pi • • nsp,ctor: Date: -�. _--- f 1 n REINSPECTION FEE REQUIRED. Pr' r to next inspection..fee must be paid at 6300 Southcenter Blvd.. S a 100. Call to schedule- reinspection... 1 • •7 ,,r1:11` �!`.'.�.%- .. '•7Y •�Y?• -+�.z fir... _ r.V. .:. ^Y.a. dA4 INSPECTION NO. INSPECTION RECORD Retain a copy with permit MI( -05D PERMIT NO. CITY OF' TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 1 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 • • • Project: , Lso- AG I -I- a Typ f Inspection: ; NrfrL Lke,,On• Address: s(d I . ){�r% J fr[ Date Called: • Special Instructions: C,s--ctore Date Wanted: - Q a (kU . BJ(, ~5n es' a.m. Requester: Phone N nn d ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: (1 ) i∎J eg I kc.)v 1 A .g../-e • Q a (kU . BJ(, ~5n es' tr -A d ( `"04 cc ess 5(-e rA, /:s A - - -- - Ilns ector: Dater / 1! ri REINSPECTION FEE REQUIRED. Prior to next inspection._ fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule'reins,pection. • = INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 ILA (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 M)(-d5 O Rro' ct: Type of Inspection: -----; Address: 101 f- Ak G.'`lh�� Date Calied: M&). Special Instructions: - S` -J . Date Wanted: aa.mm.. Requester: 41-r f Phone CO— S'5 2 — 052I ElApproved per applicable codes. aCorrections required prior to approval. /Q COMMENTS: 410 0[C J'\' tO) las 41-r f t4- &et� Ar..s- s s7 S 11r'' 1 ti . -k ICJ . Vro kkal ict-f-n .er-A=T-N,,I ! / , "------, k w A 1nn 1 C^- Date` 11( ri ❑ REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. _- ..414+ .. - INSPECTION RECORD Retain a copy with permit INSPECTION NO: PERMIT NO. mu -o l CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 P L5-� 14-'6( Type of Inspecti n: Abet �-. 2 o1� .. Address: .4 Atkins Date Called: Special Instructions: 17 bate Wanted: V { Y a.m. Requester: Phone No: Approved per applicable codes. El Corrections required prior to approval. 7 COMMENTS: CA) .5-1- S.Jiti (0J, 1� , Ins &tor: I Date: f 14 V - n� REtNSP ION FEE REQUIRED. Prior to next inspection, fee must be • paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. ti • �v ti• `r. i;7� ? ' e� : . • INSPECTIO.N..RECORD. Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Plo e.k_ t4 -- 3 , Type of qs c n: ,-- jl j n } a L Li Add 1 e' 0 Date Called: Special Instructions: ^ (Q� 3) lJ � -1 Date Wanted: 6 J.__ (( a.m. Requester: Pho2.,4 --_c r P —40'24 El Approved per applicable c des. COMMENTS: ElCorrections required pyor to approval. rA-r-r-c AP pro Sip v� 11 D (�- sLJ( •�4- P Inspe tor: (Date: / 3 (/ n REINSPECT IN FEE REQU D. Prio to next inspection. fee mutt be paid at 6300 Southcenter Blvd.. Suite 100, Call to schedule reinspection. L. May 13, 2011 • City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director Alecsis Smith Holaday Parks Inc 4600 S 134 P1 Tukwila,WA 98168 RE: Correction Letter #1 Mechanical Permit Application Number M11 -050 Boeing #14-01 — 8811 East Marginal Wy S Dear Ms. Smith, This letter is to inform you of corrections that must be addressed before your mechanical permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. The Fire Department has no corrections at this time. Building Department: Dave Larson at 206 431 -3678 if you have questions regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that two (2) sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3670. Sincerely, IrZ149 Bill Rambo Permit Technician encl File: MI 1 -050 W:\Pennit Center \Correction Letters\2011\M11 -050 Correction Letter #1.doc 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 Tukwila Building Division Dave Larson, Senior Plan Examiner Building Division Review Memo Date: May 12, 2011 Project Name: Boeing #14 -01 C Store Permit #: M11 -050 Plan Review: Dave Larson, Senior Plans Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and /or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. The refrigeration piping cannot run inside the wall of an exit stairway enclosure per the following IBC code section: 1022.4 Penetrations. Penetrations into and openings through an exit enclosure are prohibited except for required exit doors, equipment and ductwork necessary for independent ventilation or pressurization, sprinkler piping, standpipes, electrical raceway for fire department communication systems and electrical raceway serving the exit enclosure and terminating at a steel box not exceeding 16 square inches (0.010 m2). Such penetrations shall be protected in accordance with Section 713. There shall be no penetrations or communication openings, whether protected or not, between adjacent exit enclosures. Please reroute the refrigeration piping as necessary to avoid the stair enclosure. Should there be questions concerning the above requirements, contact the Building Division at 206 -431- 3670. No further comments at this time. • °PERMIT PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M11 -050 DATE: 05 -18 -11 PROJECT NAME: BOEING #14 -01 C STORE SITE ADDRESS: 8811 EAST MARGINAL WY S Original Plan Submittal Response to Incomplete Letter # X Response to Correction Letter # 1 Revision # After Permit Issued DEPART ENTS: c ` il C. uilding ivision Public Works n Fire Prevention Structural Planning Division n ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete n DUE DATE: 05-19-11 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: n APPROVALS OR CORRECTIONS: DUE DATE: 06 -16 -11 Approved Approved with Conditions Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 � PERMITCOQRDCOHM PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M11 -050 DATE: 04/27/11 PROJECT NAME: BOEING #14 -01 C STORE SITE ADDRESS: ., • ;1 0 EAST MARGINAL WY S X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # after Permit Issued DEPART ENT : t % S - -ti building Ivislon Public Works ❑ '0 tl Fire Prevention Structural Planning Division nPermit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete �J Comments: Incomplete DUE DATE: 05/03/11 Not Applicable n Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUTING: Please Route Structural Review Required No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 05/31/11 Approved ❑ Approved with Conditions n Not Approved (attach comments) kl Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only ` CORRECTION LETTER MAILED: �` t 1, ' AIQ Departments issued corrections: Bldg. Fire ❑ Ping ❑ PW ❑ Staff Initials: V'_/.�` Documents/routing slip.doc 2 -28 -02 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite # 100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http : //www.ci.tukwila,waus Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fa; etc. Date: 18 Mav 2011 Plan Check/Permit Number: M11-050 ❑ Response to Incomplete Letter # ® Response to Correction Letter # 1 ❑ Revision # ^ after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Boeing #14-01 C Store Project Address: 8811 East Marginal Wy S Contact Person: Brian Emtman Phone Number. (206) 623 0717 Summary of Revision: Refrigerant piping will be routed inside the MMR rack rooms (levels 2 and 3) and maintenance room ceiling (level 1). Refrigerant piping shall not penetrate the rated portion of the wall. OITV O TIF JCWIL MAY ►1.8 2011 PERMIT CENTER Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: - ntered in Permits Plus on t t lapplications\fonns- applications on Iinelrevision submittal Created: 8 -13 -2004 Revised: Contractors or Tradespeople *ter Friendly Page • General /Specialty Contractor A business registered as a construction contractor with LEI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name HOLADAY PARKS INC UBI No. 578004089 Phone 2062489700 Status Active Address 4600 S 134Th Pl License No. HOLADPI379NO Suite /Apt. License Type Construction Contractor City Seattle Effective Date 1/21/1983 State WA Expiration Date 9/3/2011 Zip 98168 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status HOLADI'00105 HOLADAY PARKS INC Electrical Contractor Hvac /Rfrg Ltd Energy Unused 9/25/2000 4/21/2013 Active HOLADPF376NO HOLADAY PARKS FABRCTRS INC Construction Contractor General Unused 8/20/1963 1/1/1983 Archived Business Owner Information Name Role Effective Date Expiration Date PARKS, GERALD T JR Chief Executive Officer 01/21/1983 Amount BECK, DAVID CLARENCE Vice President 01/21/1983 A1CG96431001 OCONNOR, BONNY K Vice President 01/21/1983 NAILON, JUNE ANNETTE Vice President 01/21/1983 OLD REPUBLIC GENERAL INS VAN DER VEEN, ERIC M Vice President 11/04/2010 NELSON, MICHAEL Secretary 01/01/1980 11/04/2010 PARKS, DAVID L Treasurer 01/01/1980 11/04/2010 TALBOT, PAUL Treasurer 01/01/1980 11/04/2010 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 7 LIBERTY MUTUAL INS CO 23000452 09/01/2002 Until Cancelled $12,000.00 08/23/2002 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 23 OLD REPUBLIC GENERAL INS A1CG96431001 11/01/2010 11/01/2011 $1,000,000.00 10/28/2010 22 OLD REPUBLIC GENERAL INS A1CG96430900 11/01/2009 11/01/2010 $1,000,000.00 10/29/2009 21 NATIONAL FIRE INS CO OF HARTFO 2077698833 09/01/2008 11/01/2009 $1,000,000.00 08/26/2009 20 NATIONAL FIRE INS CO OF HAR C2077698833 09/01/2005 09/01/2008 $1,000,000.00 09/02/2005 19 NATIONAL FIRE INS CO OF HART C2077698833 09/01/2004 09/01/2005 $1,000,000.00 08/25/2004 https://fortress.wa.gov/lni/bbip/Print.aspx 05/24/2011 B�EIA'& 14 -01 P -8 PROGRAM ACTIVATION 8621 EAST MARGINAL WAY SOUIH �E p� fiauw�,ER eo we: LOCAT TUKWILA, WA 98108 (P -8 C- STORE) MUKILTEO EVERETT TO EVERETT JORGENSEN CORP P1 LYNNW•OD EDMOND PROJECT SITE 14 -07 11111111111111001111111111111 111111111I--•• KENWORTH CORP ISSAQUAH RHONE POULENC Sao _.= 01 AUBURN AUBURN C7 echanical El iectricat % lumbing le Gas Piping City of Tukwila BJ..DINO DIVISION REVISIONS No changes shall be to the scope of work without prior approval of Tukwila Building Division. NOT!: Revisions will require a new plan submittal and may include additional plan review fees. C T F' A PROul-CT DhSCR PT 0\ TI RENOVATION OF THE FIRST FLOOR OF THE 14 -01 BUILDING: SCOPE INCLUDES MODIFICATIONS TO EXISTING ROOMS AND NEW GWB PARTITIONS TO ACCOMMODATE NEW C STORE FOOD SERVICE AND SHOWERS. MEP SYSTEMS ARE MODIFIED ACCORDINGLY TO SUPPORT THE NEW LAYOUT. FLOORING, PAINT, CEILING REPLACEMENT, CASEWORK, ETC. WILL ALSO BE PROVIDED DLR Group Architecture Engineering. Planning Interiors FILE COPY Permit Ntlr. 0 PI -kr review approval is subject to enure and omissions. oval. of C ;ontructlon documents does not authorize 1 <, , a' loit of any adopted code or ordinance. Receipt o. i rprovea Field Copy .. , conditions is admowiedged: By ifill ( Dom: City Of ThkevNa BUILDING DIVISION CODH LD \ C DATA HOP \LW WORD) EXISTING PERMITTED DATA — NO CHANGE TO OCCUPANCY OR USE: A\D A. INTERNATIONAL BUILDING CODE: 2009 EDITION 1. FLOOR AREAS: a) BUILDING STATUS: FIRST FLOOR OFFICE: FIRST FLOOR HIGH BAY: FIRST FLOOR MEZZANINES: SECOND FLOOR OFFICE: THIRD FLOOR OFFICE: FOURTH FLOOR MEZZANINE: GROSS AREA: b) COVERED LOADING DOCK (14 -16): 2. OCCUPANCY ALLOWED: NO CHANGE a) ACTUAL OCCUPANT LOAD: FIRST SHIFT HIGH BAY: FIRST SHIFT OFFICE TOWER: SECOND SHIFT HIGH BAY AND OFFICE: TOTAL ALL SHIFTS: b) OCCUPANCY GROUP: 3. CONSTRUCTION TYPE: \0 CHANGE 4. FIRE RESISTIVE REQUIREMENTS: NO CHANGE a) EXTERIOR NON— BEARING WALL: b) STRUCTURAL FRAME: c) PARTITIONS PERMANENT: d) SHAFT ENCLOSURES: e) FLOORS — CEILING /FLOORS: f) ROOF — CEILING /ROOF: g ) STAI RWAYS: 5. EXITS: NO CHANGE a) CORRIDORS: b) STAIR ENCLOSURES: 6. BUILDING HEIGHT: NO CHANGE a) HEIGHT (14 -01): 7. BUILDING HEIGHT IN STORIES: NO CHANGE a) FLOORS: 8. SEISMIC ZONE: B. BUILDING ACCESSIBILITY: C WIND LOAD: BASIC WIND SPEED: 85 MPH EXPOSURE CATEGORY: C 31,280 SF 187,680 SF 1,242 SF 31,280 SF 31,280 SF 31,280 SF 314,042 SF 5518 SF 300 OCCUPANTS 460 OCCUPANTS 90 OCCUPANTS 850 OCCUPANTS F -1 FACTORY (HIGH BAY) B -2 OFFICE TYPE II —B (2009 IBC) NON— COMBUSTIBLE NON— COMBUSTIBLE NON— COMBUSTIBLE 1 HOUR NON — COMBUSTIBLE NON— COMBUSTIBLE NON— COMBUSTIBLE 1 HOUR 1 HOUR 3 S.TORIES 1 MEZZANINE STORY D IBC CHAPTER 11 & ICC A117.1 REVIEWED FOR CODE COMPLIAN 4a APPROVED MAY 232011 ity of Tukwila BUILDING DIVISION IMPORTANCE FACTOR: 1.0 (FOR OCCUPANCY CATEGORY II) cmoRKnu► APR z 7 2011 PERMIT CENTER 050 REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE RECORD DRAWING (FDS) REDUCE OFFICE OFFLOAD 7 -127 BLDG. 14 -01 RE- ACTIVATION - OFFICE 993021 -00 P -8 PHASE 2 - DEMOLITION PACKAGE 1 DP JH PJ G PJ G S.CHIN DLR GROUP GC 3.31.95 E P -8 PHASE 2 - IFC PACKAGE 1 4.15.97 F P -8 PHASE 2 - IFC PACKAGE 2 3.18.99 G P -8 C -STORE - IFC DLR GROUP DLR GROUP DLR GROUP RH RH RH 02.06.11 02.13.11 04.21.11 JHILL 7.15.10 01.28.11 — � BOE /NG ROBERT HOF'MAN STATE OF WASHINGTON ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN D. PLAGENS DATE CHECKED J. HILLIER SUBTITLE COVER SHEET - OFFICE CURRENT REVISION SYMBOL DATE G 04.21.11 -ENGINEER D. PLAGENS CHECKED T. DRAG00 APPROVED G.CULTUM 6.27.94 APPROVED TITLE P -8 POSEIDON PROGRAM, PHASE 2 BUILDING 14 -001 ARCHITECTURAL MASTER COL. THOMPSON, WA SHEET GO JOB NO. 8093 -10 COMP NO, DWG NO. 14- 001 —A0 1 0:42:45 AM RJVAN LI ERE: 4/18/2011 \DI- X O1- DRAW \GS INCLUDED IN SET DRAWING NO. SHEET NO. DRAWING SUBTITLE REV DATE GF ORAL • • • 14- 001 —GO 14- 001 —G2a 14- 001 —G2b GO G2a G2b COVER SHEET INDEX OF DRAWINGS INDEX OF DRAWINGS F A A 04.21.11 04.21.11 04.21.11 ARC IT- CT"RAE 14- 001 -1A01 1A01 CODE 8c EXIT PLAN O O • 14 -001 -1 A1 OAR 14 -001 -1 Al OBR 14- 001- 1A11AR 14- 001- 1A11BR 14- 001- 2A1OAR 14 -001- 2A1OBR 14 -001 -2A11 AR 14 -001 -2A11 BR 14 -001- 3A1OAR O 14 -001 -3A1OBR O 14- 001 -3A11 AR O 14 -001 -3A11 BR 1A1 OAR FLOOR PLAN 1A1 OBR FLOOR PLAN 1A1 1 AR FLOOR PLAN 1A1 1 BR FLOOR PLAN 2A1OAR FLOOR PLAN 2A1OBR FLOOR PLAN 2A11 AR FLOOR PLAN 2A11 BR FLOOR PLAN 3A1OAR FLOOR PLAN 3A1OBR FLOOR PLAN 3A11 AR FLOOR PLAN 3A11 BR FLOOR PLAN 02.06.11 02.06.11 04.21.11 C B D C C B C 0 14 -001 —A6OR A6OR EXTERIOR BUILDING ELEVATIONS B 01.28.11 02.06.11 01.28.11 02.06.11 02.06.11 02.06,11 02.06.11 02.06.11 02.06.11 14- 001- 1A280AR 14 -001 -1 A280BR 14 -001 -1 A281 AR 14 -001 -1A281 BR 14- 001- 2A280AR 14- 001- 2A280BR 14- 001 -2A281 AR 14- 001 -2A281 BR 14- 001- 3A280AR 14- 001- 3A280BR 14- 001 -3A281 AR 14- 001 -3A281 BR 1 A28OAR REFLECTED CEILING PLAN 1 A280BR REFLECTED CEILING PLAN 1 A281 AR REFLECTED CEILING PLAN 1 A281 BR REFLECTED CEILING PLAN 2A280AR REFLECTED CEILING PLAN 2A280BR REFLECTED CEILING PLAN 2A281 AR REFLECTED CEILING PLAN 2A281 BR REFLECTED CEILING PLAN 3A280AR REFLECTED CEILING PLAN 3A280BR REFLECTED CEILING PLAN 3A281 AR REFLECTED CEILING PLAN 3A281 BR REFLECTED CEILING PLAN A B C D B B C C C D B C 01.28.11 01.28.11 04.21.11 01.28.11 02.06.11 02.06.11 02.06.11 01.28.11 02.06.11 02.06.11 02.06.11 02.06.11 0 O • O 0 0 14 -001 -1 A10A 14 -001 -1 Al OB 14- 001 -1A11A 14- 001 -1A11B 14- 001 -2A10A 14- 001 -2A10B 14- 001 -2A11 A 14- 001 -2A11B 14- 001 -3A1 OA 14- 001 -3A10B 14- 001 -3A11 A 14- 001 -3A11 B 1 A10A FLOOR PLAN 1 A10B FLOOR PLAN 1 A11 A FLOOR PLAN 1 A11 B FLOOR PLAN 2A10A FLOOR PLAN 2A10B FLOOR PLAN 2A11A FLOOR PLAN 2A11B FLOOR PLAN 3A10A FLOOR PLAN 3A10B FLOOR PLAN 3A11A FLOOR PLAN 3A11 B FLOOR PLAN B C G H C C C E C C B C 02.13.11 02.13.11 04.21.11 02.13.11 02.13.11 02.13.11 02.13.11 02.13.11 02.13.11 02.13,11 02.13,11 02.13.11 14- 001 -1 L1 OA 14 -001 -1 L1 OB 14- 001 -1L11A 14- 001 -1L11B 14- 001 -2L10A 14- 001-2L1OB 14- 001 -2L11 A 14- 001 -2L11 B 14- 001 -3L1 OA 14- 001 -3L1 OB 14— 001— 3L11 A 14- 001 -3L11 B 1L10A WORKSTATION LAYOUT PLAN 1 L1 OB WORKSTATION LAYOUT PLAN 1 L11 A WORKSTATION LAYOUT PLAN 1 L11 B WORKSTATION LAYOUT PLAN 2L10A WORKSTATION LAYOUT PLAN 2L1OB WORKSTATION LAYOUT PLAN 2L11A WORKSTATION LAYOUT PLAN 2L11B WORKSTATION LAYOUT PLAN 3L10A WORKSTATION LAYOUT PLAN 3L1OB WORKSTATION LAYOUT PLAN 3L11A WORKSTATION LAYOUT PLAN 3L11B WORKSTATION LAYOUT PLAN ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG • 14- 001 —A60 A60 EXTERIOR BUILDING ELEVATIO S E 02.06.11 02.06.11 02.06.11 02.06.11 02.06.11 02.06.11 02.06.11 02.06.11 02.06.11 02.06.11 02.06.11 02.06.11 04.21.11 0 14- 001 —A110 A110 BUILDING SECTIONS A 02.06.11 0 0 • 14- 001- 1A280A 14 -001 -1 A280B 14 -001 -1 A281 A 14- 001- 1A281B 14- 001- 2A280A 14- 001- 2A280B 14- 001 -2A281 A 14- 001 -2A281 B 1A280A REFLECTED CEILING PLAN 1A280B REFLECTED CEILING PLAN 1 A281 A REFLECTED CEILING PLAN 1 A281 B REFLECTED CEILING PLAN 2A280A REFLECTED CEILING PLAN 2A280B REFLECTED CEILING PLAN 2A281A REFLECTED CEILING PLAN 2A281B REFLECTED CEILING PLAN A B C 02.13.11 02.13.11 04.21.11 0 INCLUDED IN SET DRAWING NO, SHEET NO. DRAWING SUBTITLE REV DATE ARC ITECT.,RAL NCO \T'D 14- 001- 3A280A 14- 001- 3A280B 14- 001 -3A281 A 14- 001- 3A281B 14- 001- 4A280A 14 -001- 4A280B 14- 001 -4A281 A 14- 001- 4A281B 3A280A 3A280B 3A281A 3A281B 4A280A 4A280B 4A281A 4A281B REFLECTED CEILING PLAN REFLECTED CEILING PLAN REFLECTED CEILING PLAN REFLECTED CEILING PLAN REFLECTED CEILING PLAN REFLECTED CEILING PLAN REFLECTED CEILING PLAN REFLECTED CEILING PLAN B D B B 02.06,11 02.13,11 02.13.11 02.06.11 O 14- 001 —A200 O 14- 001 —A201 O 14- 001 —A202 A200 A201 A202 MISCELLANEOUS INTERIOR DETAILS MISCELLANEOUS INTERIOR DETAILS VIISCELLANEOUS INTERIOR DETAILS • 14- 001 —A350 A350 O 14- 001 —A351 • 14- 001 —A352 • 14- 001 —A353 A351 A352 A353 WALL TYPES RELITE TYPES DOOR SCHEDULE DOOR TYPES 14- 001 —A354 A354 replaced by A354A and A354B • 14- 001 —A354A • 14 -001 —A354B • 14 -001 —A355 A354A COLOR & MATERIAL SCHEDULE A ORIG A A354B COLOR & MATERIAL SCHEDULE A A355 DOOR AND WINDOW DETAILS ORIG O 14- 001 —A374 A374 INTERIOR ELEVATIONS ORIG • 14- 001 —A375 A375 INTERIOR ELEVATIONS ORIG • 14 -001 —L450 L450 ENLARGED PLANS — VCT LAYOUT PATTERNS ORIG • 14- 001 —A461 • 14- 001 —A462 A461 A462 ENLARGED PLANS ENLARGED PLANS ORIG ORIG O 14- 001 —A504 • 14- 001 —A506 A504 DOOR AND WINDOW DETAILS A506 CEILING DETAILS O 14- 001 —A511 O 14- 001 —A512 A511 WINDOW DETAILS A512 DETAILS • 14- 001 —A513 A513 DETAILS B ORIG ORIG ORIG 03.31.95 01.12.06 03, 31.95 04.21.11 02.06.11 04.21.11 04.21.11 02.06.11 04.21.11 04.21.11 04.21.11 02.06.11 04.21.11 04.21.11 02.06.11 04.21.11 03.31.95 04.01.99 02.06.11 02.13.11 04.21.11 FOOD S -RVi • 14- 001 —EQ100 EQ100 EQUIPMENT PLAN & SCHEDULE (FOR REF. ONLY) • 14- 001 —EQ101 EQ101 EQUIPMENT SCHEDULE (FOR REF. ONLY) 03.01.11 03.01.11 S TR CT„ RAC • 14- 001 —S212 • 14- 001 —S260 O 14- 001 —S400 S212 S260 S400 PARTIAL NORTH FRAMING ELEVATON 02.06.11 STRUCTURAL STEEL SCHEDULE STRUCTURAL STEEL DETAILS 03.31.95 03.31.95 v EC A \ICAL O 14 -001- 1M1OAR O 14- 001- 1M1OBR • 14- 001- 1M11AR O 14- 001- 2M1OAR O 14- 001-2M1OBR O 14- 001- 2M11AR O 14- 001- 2M11BR O 14- 001- 3M1OAR O 14- 001- 3M1OBR O 14- 001- 3M11AR O 14- 001- 3M11BR O 14- 001- 1M6OBR O 14- 001- 2M6OBR O 14- 001- 3M6OBR O 14 -001 -1 M110AR A B C C 02.06.11 02.13.11 02.13.11 02.06.11 14 -001 -1 M110BR O 14- 001- 1M111AR O 14- 001- 2M110AR O 14- 001- 2M110BR O 14- 001- 3M110AR O 14- 001- 3M110BR O 14- 001- 3M111BR 1M1OAR 1M1OBR 1M11AR 2M1OAR 2M1OBR 2M 11 AR 2M11BR 3M1OAR 3M1OBR 3M 11 AR 3M11 BR 1M6OBR 2M6OBR 3M6OBR 1M110AR 1M110BR 1M111AR 2M110AR 2M110BR 3M110AR 3M110BR 3M111BR DUCTWORK DUCTWORK DUCTWORK 04.21.11 DUCTWORK DUCTWORK DUCTWORK DUCTWORK DUCTWORK DUCTWORK DUCTWORK DUCTWORK HVAC PIPING HVAC PIPING HVAC PIPING PLUMBING PLUMBING PLUMBING PLUMBING PLUMBING PLUMBING PLUMBING PLUMBING INCLUDED IN SET DRAWING NO, SHEET NO. DRAWING SUBTITLE REV DATE v A 1CAL (CO\T'D • • • • 14- 001 —M2B 14- 001 —M2C 14- 001 —M2E 14- 001 —M2F M2B M2C M2E M2F EQUIPMENT SCHEDULES EQUIPMENT SCHEDULES EQUIPMENT SCHEDULES EQUIPMENT SCHEDULES C B O O • 14- 001 -1M10A 1M10A 14- 001 -1M1OB 1M1OB DUCTWORK DUCTWORK F O O O 14- 001 -1M11A 14- 001 -1M11B 14 -001 -2M10A 14- 001 -2M1OB 14- 001 -2M11A 14-001-2M11B 1M11A 14 -001 -3M10A 14 -001 -3M1OB 14- 001 -3M11 A 14- 001 -3M11 B 14- 001 -4M11A 1M11B 2M10A 2M10B 2M11A 2M11B 3M10A 3M1OB 3M11A DUCTWORK DUCTWORK DUCTWORK DUCTWORK DUCTWORK DUCTWORK DUCTWORK DUCTWORK DUCTWORK 3M11B 4M11A DUCTWORK DUCTWORK B B C A B A O • • O • O • • O O • 14 -001 -1 M60A 14 -001-1M6OB 14- 001 -1M61A 14 -001 -1M61B 14 -001 -2M60A 14- 001 -2M60B 14- 001 -2M61A 14- 001 -2M61B 14- 001 -3M60A 14- 001 -3M60B 14- 001 -3M61 A 14- 001 -3M61 B 14- 001 -4M60A 14- 001 -4M61A 1M60A 1M6OB 1M61A 1M61B 2M60A 2M60B 2M61A 2M61 B 3M60A HVAC PIPING HVAC PIPING HVAC PIPING HVAC PIPING HVAC PIPING HVAC PIPING HVAC PIPING HVAC PIPING HVAC PIPING A C A 3M60B 3M61A HVAC PIPING HVAC PIPING A B 3M61B 4M60A 4M61A HVAC PIPING HVAC PIPING HVAC PIPING O 14- 001 -4M61 B 4M61B HVAC PIPING B A A A A • O • O O 14- 001— UGM111 A 14- 001- 1M110A 14- 001- 1M110B 14- 001- 1M111A 14- 001- 1M111B 14- 001 -2M11 OA 14- 001- 2M110B UGM111A 1M110A PLUMBING PLUMBING A C 1M110B 1M111A 1M111B 2M11 OA 2M110B PLUMBING PLUMBING B PLUMBING PLUMBING PLUMBING A B O O 14- 001- 2M111A 14- 001- 2M111B 14- 001- 3M110A 2M111 A 2M111B 3M 11 OA PLUMBING PLUMBING PLUMBING 14- 001- 3M110B O 14- 001- 3M111A 14- 001- 3M111B 3M11 0B 3M111A 3M111B PLUMBING PLUMBING PLUMBING • • 14- 001 -1M452 14- 001 —M530 1M452 DUCTWORK M530 DUCTWORK 04.21.11 04.21.11 04.21.11 04.21.11 02.13.11 02.13.11 04.21.11 02,06.11 02.06.11 02.06.11 02.06.11 02.06.11 02,06.11 02.06.11 02.06.11 04.21.11 04.21.11 04.21.11 04.21.11 02.06.11 04.21.11 02.13.11 04.21.11 04.21.11 02.06.11 02.13.11 04.21.11 02.13.11 04.21.11 04.21.11 04.21.11 02.06.11 02.06.11 02.06.11 02.06.11 02.06.11 04.21.11 04.21.11 1111-05-6 100% SUBMITTAL ISSUED FOR CONSTRUCTION SSUE LEGE \D )9( NOT YET ISSUED PREVIOUSLY ISSUED FOR CONSTRUCTION. THIS ISSUE CONTAINS ADDITIONAL INFORMATION. PREVIOUSLY ISSUED AND NOT PART OF THIS ISSUE, OR PENDING NOT YET ISSUED. INCLUDED IN THIS ISSUE PREL PRELIMINARY ISSUE FOR REVIEW OR INFORMATION ONLY NOT FOR CONSTRUCTION ORIG A ORIGINAL ISSUE FOR PERMIT, BID, PROCUREMENT OR CONSTRUCTION DRAWING REVISION — SEE SPECIFIC DRAWING FOR NATURE OF REVISION ? REVIEWED FOR CODE COMPLIANCE t APPROVED MAY 2 3 2011 / Cityof kila !U6T8ixfl,tI ILDIN CITY ORSL4 APR 2 7 2011 PERMIT CENTER DLR Group Architecture Engineering Planning int in SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE ORI P -8 PHASE 2 - IFC PACKAGE 1 A P -8 PHASE 2 - IFC PACKAGE 2 DLR GROUP NM DLR GROUP RJV 02.06.11 02.13.11 B P -8 PHASE 2 - DEMOLITION PACKAGE 2 DLR GROUP RJV 02.16.11 C P -8 C -STORE - IFC DLR GROUP RH 04.21.11 Q�BOE /NG ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED DRAWN DATE APPROVED BY DEPT. DATE CHECKED ENGINEER SUBTITLE INDEX OF DRAWINGS CURRENT REVISION SYMBOL C DATE 04.21.11 CHECKED APPROVED APPROVED TITLE P -8 POSEIDON PROJECT, PHASE 2 ARCHITECTURAL MASTER BUILDING 14 -001 SHEET G2A JOB NO. COMP NO. THOMPSON, WA DWG NO. 14- 001 —G2A LEGE \D 1. FOR MECHANICAL LEGENDS AND ABBREVIATIONS SEE SHEETS M 1 a, M 1 b AND M 1 c. 14/24 LOUVER 400 CFM 210 CFM SA 165 CFM ©(TYP 6) TRANSFE 80 TYP 4 �12 6 FOR RA 0 cD 48/14 TRANSFER DUCT GE \ERAL \OTES 1. ITEMS SHOWN AS "LIGHT" LINEWEIGHT ARE EXISTING AND TO REMAIN. ITEMS SHOWN AS "BOLD" LINEWEIGHT AND "DASHED" ARE TO BE REMOVED OR RELOCATED. 2. THE NEW LOCATION OF ITEMS INDICATED AS RELOCATED IS SHOWN ON THE NEW DESIGN DRAWINGS. SEE CONSTRUCTION NOTES THIS SHEET FOR ADDITIONAL INFORMATION. 3. CONTRACTOR SHALL SALVAGE AND RETAIN ALL EXISTING DIFFUSERS, GRILLES, AND REGISTERS INDICATED TO BE REMOVED. RE —USE EXISTING SALVAGED ITEMS WHERE POSSIBLE DURING CONSTRUCTION OF NEW DESIGN AND LAYOUT. 4. CONTRACTOR SHALL SALVAGE AND RETAIN ALL EXISTING VAV TERMINAL UNITS INDICATED TO BE REMOVED. WHERE EXISTING UNITS WILL BE RE —USED, LOCATION WILL BE INDICATED ON THE NEW DESIGN DRAWINGS. SA 130 1: CFM 41/12 -e- UP TO 220 FIRE DAMPER AT FLOOR PENETRATION PARTIAL PLA\ VIEW - RE SCALE: 1/8"=1"-0" REFERE 1M11A \CE DRAWI \GS CO \STRUCTIO\ NOTES REMOVE EXISTING DIFFUSER, GRILLE, OR REGISTER. RELOCATE EXISTING DIFFUSER, GRILLE, OR REGISTER. REMOVE EXISTING BRANCH DUCTWORK AS INDICATED. CAP EXISTING BRANCH DUCTWORK AT MAIN DUCT BRANCH. REMOVE EXISTING BRANCH DUCTWORK AS INDICATED, EXISTING DIFFUSER SHALL REMAIN. EXISTING THERMOSTAT TO BE RELOCATED WHEN NEW PARTITIONS HAVE BEEN INSTALLED. EXISTING VAV TERMINAL UNIT TO BE RELOCATED. EXISTING COMPUTER ROOM A/C UNIT TO BE REMOVED. COFFMAN N GIN E E R S 1601 Fifth Avenue Suite 900 Seattle, Washington 98101 -1625 206 623 0717 Fax 206 624 3775 REMOVAL 1M1OAR 1M1OBR 1M11AR 1M11BR 1M12 1M13 1M14 1M15 1M16 1M17 1M18 1M19 KEY PLAN SCALE: NONE cmr�W APR 2 7 2011 PERMIT CENTER SCALE: 1 /8 " =1' -0" REVISION APPROVED B 1 REMODEL QA OFFICE J D83P0202 GAVRAS REVISION APPROVED GAVRAS 03.02.98 CAD CONVERSION CADDNW 04.22.98 C I P -8 PHASE 2— DEMOLITION PACKAGE 1 D I P -8 PHASE 2— DEMOLITION PACKAGE 2 01.28.11 02.16.11 LBOE /NG ° d� ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DRAWN S. LOPER CHECKED SCHELLPFEFFER ENGINEER SCHELLPFEFFER CHECKED K. WIKSTROM APPROVED K. RAMSEY APPROVED SUBTITLE CURRENT REVISION DUCTWORK SYMBOL E 04.21.11 TITLE P -8 POSEIDON PROGRAM, PHASE 2 07.25.94 E P -8 C— STORE —IFC CEI MS 04.21.11 MECHANICAL MASTER BUILDING 14 -001 COL.B— C/12.4 -16 THOMPSON. WA SHEET IMIIAR JOB NO. DWG NO. COMP NO. M N U 14- 001 - 1M11AR VARIABLE AIR VOLUME TERMINAL UNIT SCHEDULE MARK NUMBER VFW -101 PRIMARY AIR QT(. MAX. MIN. (CFM) 340/140 PRIMARY AIR STATIC INLET (INCHES W.G.) MAX. NC LEVEL 1.5" WG INLET SIZE INLET /ORIFICE (INCHES) HEATING FAN COIL CFM HP VOLT PH HZ MBH GPM EWT T LWT T REMARKS 1.36 35 155 1/10 120 1 60 10 1.0 200 180 TEMPMASTER, SIZE B W/ FAN VFW -102 1605/645 .82 35 10 "/- 725 1/4 120 1 60 17 .50 200 124 TEMPMASTER, SIZE E W/ FAN VFW -103 2110/844 .98 35 12 "/- 950 1/3 120 1 60 28 .90 200 140 TEMPMASTER, SIZE F W/ FAN VFW -104 300/120 1.22 35 6" 135 1/10 120 1 60 11 1.0 200 180 W/ FAN VFW -105 1739/695 1.23 35 10"/- 783 1/4 120 1 60 18 .50 200 123 TEMPMASTER, SIZE E W/ FAN VFW -106 1160/464 1.1 35 10"/- 522 1/4 120 1 60 13 .50 200 143 TEMPMASTER, SIZE E W/ FAN VFW -107 1145/458 1.05 35 10"/- 515 1/4 120 1 60 15 .50 200 133 TEMPMASTER, SIZE E W/ FAN VFW -108 2400/960 .70 35 14 "/- 1080 1/2 120 1 60 31 .90 200 133 W/ FAN VFW -108A 440/175 .70 35 6" 200 1/10 120 1 60 10 1.0 200 180 TEMPMASTER, SIZE B W/ FAN VFW -109 900/360 1.04 35 8» 405 1/6 120 1 60 13 .50 200 146 TEMPMASTER, SIZE D W/ FAN VFW -110 160/65 .93 35 6" 75 1/10 120 1 60 7 .50 200 174 TEMPMASTER, SIZE B W/ FAN VFW -111 291/116 1.20 35 6" 131 1/10 120 1 60 8 1.0 200 184 TEMPMASTER, SIZE B W/ FAN VCC -112 530/320 1.22 35 6" TEMPMASTER, SIZE B VCC -113 550/220 1.10 35 6" TEMPMASTER, SIZE B VCC -114 253/101 1.08 35 5" /- 114 TEMPMASTER, SIZE A VFW -115 223/89 VCC -116 VFW -117 VFW -118 VFW -1 92/396 VCC -12 288/115 1.27 35 6" 100 1/10 120 1 60 7 1.0 200 186 TEMPMASTER, SIZE B W/ FAN 1.04 35 8» . 98 35 6 "/4.0 .79 35 .69 35 1 1.06 35 225 446 574.5 130 TEMPMASTER, SIZE D 1/10 120 1 60 .50 200 177 TEMPMASTER, SIZE B W/ FAN 1/10 120 1 60 11 1.0 200 178 TEMPMASTER, SIZE B W/ FAN 1/4 120 1 60 19 1.1 200 166 TEMPMASTER, SIZE E W/ FAN TEMPMASTER, SIZE A VFW -121 1400/560 .77 35 10"/- 630 1/4 120 60 18 .50 200 122 TEMPMASTER, SIZE E W/ FAN VCC -122 324/129 1.15 35 6 "/4.5 146 TEMPMASTER, SIZE B VFW -123 764/305 .76 35 8" 344 1/6 120 1 60 13 .50 200 145 TEMPMASTER, SIZE D W/ FAN VFW -124 972/388 .72 35 437 1/6 120 60 14 .50 200 137 W/ FAN VFW -125 713/285 1.29 35 8" / 321 1/6 120 1 60 13 .50 200 145 TEMPMASTER, SIZE D W/ FAN VFW -126 1701/680 . 92 35 10 "/9.5 765 1/4 120 1 60 17 .50 200 124 TEMPMASTER, SIZE E W/ FAN VCC -127 1231/492 1.03 35 1078.0 554 TEMPMASTER, SIZE E VCC -128 152/60 .76 35 673.0 68 TEMPMASTER, SIZE B VCC -129 777/310 1.06 35 8 "/6.5 350 VFW -130 526/210 .80 35 6" 237 1/10 120 1 60 11.0 .50 200 157 TEMPMASTER, SIZE B W/ FAN VFW -131 420/190 1.42 35 6" 216 1/10 120 1 60 .60 200 167 TEMPMASTER, SIZE B W/ FAN VFW -132 1761/704 .99 35 10 "/- 792 1/4 120 1 60 18 .50 200 123 TEMPMASTER, SIZE E W/ FAN VFW -133 770/310 1.21 35 8" 350 1/6 120 1 60 14 .50 200 139 TEMPMASTER, SIZE D W/ FAN VFW -134 260/104 .81 35 6 "/4.0 117 1/10 120 1 60 8 . 60 200 174 TEMPMASTER, SIZE B W/ FAN VFW -135 296/118 1.24 35 6 "/4.5 133 1/10 120 1 60 9 . 90 200 181 TEMPMASTER, SIZE B W/ FAN VFW -136 1000/400 35 10"/- 450 1/10 120 1 60 15 200 160 NAILOR 35NW, SIZE 2 VCC -137 500/200 35 7" NAILOR 3001, SIZE 7 VFW -138 300/135 35 150 1/10 120 1 60 7 200 160 NAILOR 35NW, SIZE 2 VFW -201 422/168 1.23 35 6" 190 1/10 120 1 60 10 .50 200 158 TEMPMASTER, SIZE B W/ FAN VFW -202 2245/900 1.01 35 147- 1010 1/2 120 1 60 29 .90 200 137 TEMPMASTER, SIZE G W/ FAN SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE RECORD DRAWING (FDS) MJC KW KR 03.31.95 A OFFLOAD 7-127 BUILDING MAF TLD 03.18.99 B P-8 PHASE 2 - DCN 1 CEI MS 02.24.11 C P-8 PHASE 2 - DCN 4 CEI MS 03.04.11 D P-8 C-STORE-IFC CEI MS 04.21.11 VARIABLE AIR VOLUME TERMINAL UNIT SCHEDULE MARK NUMBER PRIMARY AIR QTY. MAX./MIN. (CFM) PRIMARY AIR STATIC INLET (INCHES W.G.) MAX. NC LEVEL INLET 1.5" WG INLET SIZE HEATING REMARKS /ORIFICE FAN COIL (INCHES) • CFM HP VOLT PH HZ MBH GPM EWT T LWT `F VCC -203 1045/420 1.21 35 10 "/- - - - - - - - - TEMPMASTER, SIZE E VFW -204 560/225 .74 35 10 "/- 250 1/4 120 1 60 15 .50 200 135 TEMPMASTER SIZE E W /FAN VFW -205 1150/460 1.18 35 107- 520 1/4 120 1 60 16 .50 200 130 TEMPMASTER AN SIZE E W /F VFW -206 600/240 1.07 35 6'/- 270 1/10 120 1 60 9 .50 200 163 TEMPMASTER SIZE B W /FAN VFW -207 230/100 1.10 35 6 "/3.5 105 1/10 120 1 60 6 .50 200 175 TEMPMASTER SIZE B W /FAN VCC -208 300/120 1.08 35 67- - - - - - - - - - TEMPMASTER SIZE B VFW -209 1039/415 .72 35 10 "/- 468 1/4 120 1 60 15 .50 200 135 TEMPMASTER SIZE E W /FAN VFW -210 1636/654 .81 35 12 "/- 736 1/3 120 1 60 25 .90 200 146 TEMPMASTER SIZE F W /FAN VFW -211 320/130 .70 35 " 674.0 145 1/10 120 1 60 8 .50 200 167 TEMPMASTER SIZE B W /FAN VFW -212 530/210 1.04 35 6 "/4.5 240 1/10 120 1 60 8 .50 200 167 TEMPMASTER SIZE B W /FAN VCC -213 270/110 1.27 35 6 "/- - - - - - - - - - TEMPMASTER SIZE B VFW -214 419/167 1.24 35 6"/- 189 1/10 120 1 60 10 .50 200 158 TEMPMASTER SIZE B W /FAN VFW -215 1560/625 1.10 35 12"/- 700 1/3 120 1 60 24 .90 200 147 TEMPMASTER SIZE F W /FAN VFW -216 1505/602 1.14 35 12 "/- 677 1/3 120 1 60 24 .90 200 148 TEMPMASTER SIZE F W /FAN VFW -217 1384/553 1.1 35 �� 107- 623 1/4 120 1 60 17 .50 200 138 TEMPMASTER SIZE E W /FAN VFW -218 364/145 1.22 35 6"/- 164 1/10 120 1 60 9 .50 200 161 TEMPMASTER SIZE B W /FAN VFW -219 530/215 .97 35 6 /- 240 1/10 120 1 60 11 .50 200 153 TEMPMASTER SIZE B W /FAN VFW -220 523/209 .87 35 6 "/- 235 1/10 120 1 60 11 .50 200 152 TEMPMASTER SIZE B W /FAN VFW -221 416/166 .92 35 6 "/- 187 1/10 120 1 60 10 .50 200 158 TEMPMASTER SIZE B W /FAN VFW -222 1556/622 .85 35 12"/- 700 1/3 120 1 60 24 .90 200 147 TEMPMASTER SIZE F W /FAN VFW -223 1744/697 .68 35 12 "/- 785 1/3 120 1 60 26 .90 200 144 TEMPMASTER SIZE F W /FAN VFW -224 808/323 .78 35 8 "/- 363 1/6 120 1 60 13 .50 200 142 TEMPMASTER SIZE D W /FAN VFW -225 221/88 .89 35 6 "/4.0 99 1/10 120 1 60 7 .50 200 170 TEMPMASTER SIZE B W /FAN VFW -226 370/148 1.05 35 6 "/- 167 1/10 120 1 60 9 .50 200 161 TEMPMASTER SIZE B W /FAN VCC -227 440/180 1.11 35 6 "/- - - - 1 - - - - - TEMPMASTER SIZE B VFW -228 600/240 1.16 - 67- 270 1/10 120 1 60 12 .50 200 149 TEMPMASTER FAN SIZE B W / VFW -229 1240/500 1.20 - 107- 560 1/4 120 1 60 15 .50 200 135 TW /FAN EMPMASTER SIZE E VFW -230 680/270 - - 87- 310 1/10 120 1 60 - - 200 160 NAILOR 35NW, SIZE 2 VFW -300 415/166 1.20 35 6"/- 186 1/10 120 1 60 10 .50 200 158 TEMPMASTER SIZE B W /FAN VFW -301 540/220 .91 35 67- 245 1/10 - - - 11 .50 200 151 TEMPMASTER SIZE B W /FAN VFW -302 1117/446 1.24 35 107- 503 1 /4 - - - 15 .50 200 133 TEMPMASTER SIZE E W /FAN VFW -303 206/82 .79 35 �� 67- 93 1/10 120 1 60 7 .50 200 171 TEMPMASTER SIZE B W /FAN VFW -304 200/80 .99 35 6"/4.0 90 1/10 120 1 60 7 .50 200 168 TEMPMASTER SIZE B W /FAN VFW -305 1136/454 1.25 35 107- 511 1/4 120 1 60 15 .50 200 133 TEMPMASTER SIZE E W/FAN VFW -306 545/220 .91 35 6 "/- 245 1/10 120 1 60 11 .50 200 152 TEMPMASTER SIZE B W /FAN VFW -307 530/215 1.12 35 6 "/- 240 1/10 120 1 60 11 .50 200 152 TEMPMASTER SIZE B W /FAN VFW -308 932/372 .87 35 8 "/- 419 1/6 120 1 60 14 .50 200 138 TEMPMASTER SIZE D W /FAN VFW -309 355/145 1.40 35 67- 160 1/10 120 1 60 9 .50 200 159 TEMPMASTER SIZE B W /FAN VFW -310 870/350 .82 35 8 "/- 395 1/6 120 1 60 14 .50 200 140 TEMPMASTER SIZE D W /FAN 111 1%.-0 Sur) REVIEWED FOR r CODE COMPLIANCE APPROVED MAY 2 3 2011 ciARIviuk City ot Tukwila BUILDING niviRinrg AFOFFMAN 1601 Fifth Avenue Suite 900 PERMIT CENTER Seattle, Washington 98101-1625 206 623 0717 Fax 206 624 3775 100% SUBMITTAL ISSUED FOR CONSTRUCTIO THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN D. DAVIS CHECKED SCHELLPFEFFER ENGINEER SCHELLPFEFFER CHECKED K. WIKSTROM APPROVED K. RAMSEY APPROVED DATE SUBTITLE EQUIPMENT SCHEDULES CURRENT REVISION SYMBOL DATE 04.21.11 07.25.94 TITLE P-8 POSEIDON PROJECT, PHASE 2 MECHANICAL MASTER BUILDING 14-001 THOMPSON, WA SHEET M2B JOB NO. COMP NO. DWG NO. NMILLER: 01/25/11 16:39 NMILLER: 01/25/11 16:45 VARIABLE AIR VOLUME TERMINAL UNIT SCHEDULE AIR DIFFUSER / REGISTER / GRILLE SCHEDULE `" 1 MARK NUMBER PRIMARY AIR QTY. MAX. /MIN. (CFM) PRIMARY AIR STATIC INLET (INCHES W.G.) MAX. NC LEVEL © 1.5" WG INLET SIZE INLET /ORIFICE (INCHES) HEATING REMARKS MARK NUMBER EA -1 TYPE EGG CRATE MATERIAL ALUMINUM 1/2x1/2x1/2 FINISH WHITE INLET /NECK SIZE, INCHES 18X18 MAX. NOISE COEFFICIENT 25 MAX. TP INCH WG. .049 MAXIMUM SET CFM 1344 REMARK J & J MODEL ALEC -5, FRAME 33, LAYIN FAN COIL CFM HP VOLT PH HZ MBH GPM EWT T LWT °F VFW -312 635/255 .67 35 8 "/- 285 1/6 120 1 60 14 .50 200 137 TEMPMASTER, SIZE D W /FAN EA -2 CEILING GRILLE STEEL WHITE 6X6 _ _ _ J & J MODEL S9OZH, FRAME WITH SCREW HOLES VFW -313 621/249 1.03 35 8"/- 279 1/6 120 1 60 12 .50 200 149 TEMPMASTER, SIZE D W /FAN EA -3 EGG CRATE ALUMINUM 1/2x1/2x1/2 WHITE 12X12 - .07 540 J & J MODEL ALEC -5, FRAME 33, LAYIN VFW -314 864/346 .81 35 8 "/- 389 1/6 120 1 60 14 .50 200 140 TEMPMASTER, SIZE D W /FAN EA -4 EGG CRATE 1 ALUMINUM WHITE 9x9 10 .079 300 SURFACE MODEL ALEC -5, FRAME 32, VFW -315 796/319 .80 35 8 "/- 358 1/6 120 1 60 13 .50 200 142 TEMPMASTER, SIZE D W /FAN EA -5 EGG CRATE ALUMINUM 1/2x1/2x1/2 WHITE 10x10 - .07 300 J & J MODEL ALEC -5, FRAME 33, LAYIN VFW -316 480/194 .96 35 6 "/- 217 1/10 - - - 11 .50 200 154 TEMPMASTER, SIZE B W /FAN EA -6 EGG CRATE ALUMINUM 1/2x1/2x1/2 WHITE 14x 14 - 05 500 J & J MODEL ALEC -5, FRAME 32, WITH SCREW HOLES VFW -317 _ _ _ _ _ _ _ _ _ _ _ - - NOT USED EA -7 EGG CRATE ALUMINUM WHITE 12X12 - .07 540 J & J MODEL ALEC -5, FRAME 32, WITH SCREW HOLES VFW -318 259/104 1.3 35 6 "/- 117 1/10 120 1 60 7 .50 200 168 TEMPMASTER, SIZE B W /FAN EL--; FI . 1 B, I e U ■ M W. 8 A: 1; 2.' TITUS MODEL 350FL . . . • VFW -319 185/75 '1.02 35 6 "/4.0 85 1/10 - - - 7 .50 200 171 TEMPMASTER; SIZE B W /FAN EA -9 EGG CRATE ALUMINUM CORE 1/2x1/2x1/2 WHITE 22X10 - .024 550 TITUS MODEL 50F VFW -320 495/200 .90 35 6 "/- 225 1/10 120 1 60 11 .50 200 152 TEMPMASTER, SIZE B W /FAN 'A -1 GG 'ATE 1/2x1/2x1/2 " IT 2X1 • 30 - LAYIN VFW -321 840/336 1.14 35 8 "/- 378 1/6 120 1 60 14 .50 200 141 TEMPMASTER, SIZE D W /FAN RA -2 EGG CRATE ALUMINUM CORE WHITE 22X22 30 -1/2x1/2x1/2 J & J MODEL ALEC -5, FRAME 33, LAYI N VFW -322 450/180 .97 35 6 "/4.0 205 1/10 120 1 60 7 .50 200 169 TEMPMASTER, SIZE B W /FAN RA -3 EGG CRATE ALUMINUM CORE 1 /2x 1 /2x 1 /2 WHITE - 30 - - J & J MODEL ALEC -5, FRAME 32, SURFACE MOUNTED VFW -323 800/320 1.22 35 8 "/- 360 1/6 120 1 60 12 .50 200 147 TEMPMASTER, SIZE D W /FAN RA -4 SIDE WALL STEEL WHITE 48X96 37 .12 22500 J & J MODEL S9OZH, FRAME WITH SCREW HOLES VFW -324 580/235 .71 35 8 "/- 260 1/6 120 1 60 15 .50 200 136 TEMPMASTER, SIZE D W /FAN RA -6 EGG CRATE ALUMINUM CORE 1/2x1/2x1/2 WHITE 14X10 33 .165 . 800 J & J MODEL ALEC -5, FRAME 32, SIDEWALL MTG. VFW -325 800/320 .79 35 8 "/- 360 1/6 120 1 60 13 .50 200 142 TEMPMASTER, SIZE D W/FAN RA -7 EGG CRATE ALUMINUM CORE 1/2x1/2x1/2 WHITE 22X10 - .024 550 TITUS MODEL 50F VFW -326 870/350 .84 35 8 "/- 395 1/6 120 1 60 13 .50 200 142 TwE/MFANASTER, SIZE D RA -8 EGG CRATE ALUMINUM CORE 1/2x1/2x1/2 WHITE 22X22 - .024 1200 TITUS MODEL 50F VFW -327 300/120 .84 35 8 "/- 135 1/6 - - - 12 .50 200 146 TEMPMASTER, SIZE D W /FAN RA -9 DUCT MOUNTED GRILLE STEEL WHITE 10X8 24 .10 340 TITUS MODEL 350RL VFW -328 750/300 .73 35 8 "/- 340 1/6 120 1 60 14 .50 200 138 TEMPMASTER, SIZE D W /FAN SA -1 4 -WAY STEEL WHITE 6X6 15 .092 130 J & J MODEL 1444, FRAME 33, LAYI N VFW -329 525/210 .93 35 6 "/- 240 1/10 - - - 10 .50 200 158 TEMPMASTER, SIZE B SA -2 4 -WAY STEEL WHITE 8X8 17 .092 260 J & J MODEL 1444, FRAME 33, LAYIN VFW -330 436/175 .84 35 6 "/- 196 1/10 120 1 60 10 .50 200 157 TEMPMASTER, SIZE B W /FAN SA -3 4 -WAY STEEL WHITE 10X10 19 092 410 J & J MODEL 1444, FRAME 33, LAYIN VFW -331 540/216 1.15 35 6 "/- 243 1/10 120 1 60 11 .50 200 151 TEMPMASTER, SIZE B W /FAN SA -4 4 -WAY ALUMINUM WHITE 14X14 15 .092 125 J & J MODEL AL -1444, FRAME 32, SURFACE MOUNTED VFW -332 270/110 1.04 35 6 "/4.5 125 1/10 120 1 60 8 .50 200 164 TEMPMASTER, SIZE B W /FAN SA -5 4 -WAY ALUMINUM WHITE 6X6 15 .059 125 J & J MODEL AL -1444, FRAME 32, SURFACE MOUNTED VFW -333 473/190 1.00 35 6"/- 213 1/10 120 1 60 11 .50 200 154 W M ANASTER, SIZE B / SA -6 4 -WAY STEEL WHITE 6X6 10 019 100 TITUS MODEL MCD LAYI N VFW -334 713/285 .77 35 8 "/- 321 1/6 120 1 60 13 .50 200 145 TEMPMASTER, SIZE D W /FAN SA -7 4 -WAY STEEL WHITE 8X8 12 .035 200 TITUS MODEL MCD LAYIN VFW -335 745/298 .79 35 8 "/- 335 1/6 120 1 60 13 .50 200 144 TEMPMASTER, SIZE D W /FAN SA -8 4 -WAY STEEL WHITE 10X10 20 .060 380 TITUS MODEL MCD LAYI N VFW -336 1342/537 .77 35 10"/- 604 1 /4 120 1 60 16 .50 200 129 TEMPMASTER, SIZE E W /FAN SA -9 SQUARE DIFFUSER STEEL WHITE 80 11 .036 200 TITUS MODEL TMS LAYIN VFW -337 1121/449 .97 35 10 "/- 504 1/4 120 1 60 15 .50 200 133 W /FANASTER, SIZE E SA -10 SQUARE DIFFUSER STEEL WHITE 100 14 .051 380 TITUS MODEL TMS LAYIN VFW -338 300/120 300 / 1.02 35 6 "/- 135 1/10 120 1 60 7 .50 200 170 TEMPMASTER, SIZE B W /FAN SA -11 LINEAR SLOT ALUMINUM WHITE 80 30 .060 110 TITUS MP -39, 24" LENGTH, (2) 1" SLOTS W/ TITUS MPI -39 INSULATED PLENUM VFW -339 480/195 .86 35 6 "/- 220 1/10 120 1 60 10 .50 200 156 TEMPMASTER, SIZE B W /FAN A SPIRAL �DUCT MOUNTED T W- a 6 1 U 01 SA -13 4 -WAY ALUMINUM WHITE 6X6 15 .03 130 TITUS MCD -AA SURFACE MOUNTED VFW -340 586/235 1.19 35 6 "/- 264 1/10 120 1 60 12 .50 200 150 TEMPMASTER, SIZE B W /FAN - 'GRILLE DOUBLE DEFLECTION • IT 3 1180 J i J le DEL • • OH VFW -341 510/205 - - 8 "/- 230 1/10 120 1 60 11 - 200 150 NAILOR 35NW, SIZE 2 SG-2 GRILLE DOUBLE DEFLECTION J & J MODEL 990H SG -3 SIDEWALL GRILLE STEEL DOUBLE DEFLECTION WHITE 10X6 12 .02 200 J & J MODEL 990H M l SG -5 SIDEWALL GRILLE STEEL WHITE 12X8 10 .01 100 J & J MODEL S9OZH, FRAME WITH SCREW HOLES SG -6 SIDEWALL GRILLE STEEL WHITE 12X8 10 .01 100 J& J MODEL S9OZH, FRAME WITH SCREW HOLES REVIEWED FOR CODE COMPLIANCE . APPROVED SR -1 SUPPLY GRILLE STEEL WHITE 12X4 31 .20 250 J & J MODEL 990H WITH OBD DAMPER SR -2 SUPPLY GRILLE STEEL WHITE 14X6 26 .13 340 J & J MODEL 990H WITH OBD DAMPER \ MAY 2 3 2011 City of Tukwila BUILDING IDIVIRION NOTE: STATIC PRESSURE DOWN STREAM OF VAV BOX, 0.5 INCH WG COOLING, 0.35 INCH WG HEATING. SPACE HEATING FLOW= MINIMUM PRIMARY FLOW + FAN FLOW. CONNECTIONS ON 10 ", 12 ", & 14" DIAMETER ARE EQUIVALENT FLAT OVAL. SR -3 SUPPLY GRILLE STEEL WHITE 24X10 31 .14 750 J & J MODEL 990H WITH OBD DAMPER SR -4 SUPPLY GRILLE STEEL WHITE 16X10 26 .09 1000 J & J MODEL 990H WITH OBD DAMPER 040$41 LA APR 27 2011 PERMIT CENTER COFFMAN 1601 NfthGAvenuN SEiteE90R S Seattle, Washington 98101 -1625 10 0 % SUBMITTAL SR -5 SUPPLY GRILLE STEEL WHITE 30X12 34 .13 1660 J & J MODEL 990H WITH OBD DAMPER ISSUED FOR CONSTRUCTIO TG -1 SIDEWALL GRILLE STEEL WHITE 16X 12 24 .04 1000 J & J MODEL S9OZH, FRAME WITH SCREW HOLES TG -2 FIXED BLADE ALUMINUM WHITE 10X10 10 .03 230 TITUS MODEL 350FL SURFACE MOUNT 206 623 0717 Fax 206 624 3775 SYM A B C REVISION RECORD DRAWING (FDS) P -8 PHASE 2 - DCN 1 P -8 PHASE 2 - DCN 4 P -8 C- STORE -IFC BY KW MJC K CEI CEI CEI APPROVED KR MS MS MS DATE 03.31.95 02.24.11 03.04.11 04.2, .11 SYM REVISION BY APPROVED DATE eL411417E,AW®' L S ,~��� O� &• ��. ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED DRAWN D.DAVIS DATE SUBTITLE EQUIPMENT SCHEDULES CURRENT REVISION SYMBOL c I\/ DATE 04.21.11 SCHELLPFEFFER SHEET M2C ENGINEER SCHELLPFEFFER TITLE P -8 POSEIDON PROJECT, PHASE 2 % APPROVED BY DEPT. DATE �i .� ? CHECKED K. WIKSTROM 1 BUILDING 1400 1 JOB NO. COMP N0. t � X88 .o K PROMSEY 07.25.94 APPROVED MECHANICAL MASTER THOMPSON, WA DWG N0. 14- 001 -M2C /am c►L NMILLER: 01/25/11 16:45 PUMP SCHEDULE MARK NUMBER LOCATION MARK NUMBER SERVICE FLUID TEMP T CAPACITY APPROX OPERATING WEIGHT (POUNDS) SIZE (IN) CONSTRUCTION PERFORMANCE MOTOR PUMP TYPE MANUFACTURER AND MODEL REMARK GPM TDH SUCT DISCH BODY FITTINGS EFF NPF HR DRIVE TYPE HP VOLTS PH HZ RPM HWHP -1 TOWER H2O 200 670 80 - 6 - 4 - - - - DIRECT 20 460 60 3 1760 END SUCTION PACO SMART PUMP 11- 40127- 2A6201 - HWHP -2 TOWER H2O 200 670 80 ELECTRIC WATER COOLER 6 1 1/2 6 - - - - DIRECT 25 460 60 3 1770 END SUCTION BYRON JACKSON 6x6 x11 TXP BAR SINK HWHP -3 HIGH BAY H2O 200 432 50 P -8 6 3 4 - - - - DIRECT 7 1/2 460 60 3 1755 END SUCTION BYRON JACKSON 4x6x 9 TRX -P P -9A HWHP -4 HIGH BAY H2O 200 432 50 NOT USED 6 EYE -WASH AND SAFETY- SHOWER 4 - - - - DIRECT 7 1/2 460 60 3 1755 END SUCTION BYRON JACKSON 4x6x 9 TRX -P NOT USED HWHP -5 HIGH BAY RTAHU H2O 200 350 80 - 4 P -12A 3 CI - - - DIRECT 10 460 60 3 1745 END SUCTION PACO SMART PUMP 11- 30955 - 233201 - HWHP -6 HIGH BAY RTAHU H2O 200 350 80 - 4 SEE PLAN FOR SIZE 3 CI - - - DIRECT 10 460 60 3 1745 END SUCTION PACO SMART PUMP 11- 30955 - 233201 - CHWP -1 TOWER H2O 95 66 80 1 1 /4 1 1 /4 CI CI 55.1 7.71 DIRECT 3 460 60 3 1750 SUCTION 1B81 /45 BC SINGLE MECHANICAL SEAL CHWP -2 TOWER DATA CLOSET H2O 95 66 80 1 1 /4 1 1 /4 CI CI 55.1 7.71 DIRECT 3 460 60 3 1750 SUCTION 16&G1510 1 1/4 BC SINGLE MECHANICAL SEAL HWCP -1 HWH -1 H2O 140 10 8 3/4 3/4 BRONZE BRONZE - - DIRECT 1/25 115 60 1 1750 INLINE S�LC -30B ALL BRONZE SELF LUBRICATING SP -7 SEWAGE LIFT H2O 140 510 55 - 4 - - - - - 15 480 60 3 1750 SUBMERSIBLE PACO DUPLEX SEWAGE LIFT STATION CHEMICAL FEED POT (CFP) SCHEDULE MARK NUMBER LOCATION SERVICE CAPACITY GALLONS MAX WORKING PRESSURE PSIG INLET /OUTLET SIZE (INCH) OVERALL DIMENSION INCHES APPROX OPERATING WEIGHT (POUNDS) REMARKS CFP -1 4TH FLR COL. B/14.4 CHILLED WATER 5 200 3/4 "/3/4" 10 "DIAx21 5/8 "H 100 J.L. WINGART F -511D W /40 MICRON FILTER - 16 1/4 "DIAx56" 125 20 ASME B &G D -80V (H) HANDICAP P -3 LAVATORY VESSEL — EXPANSION TANK (EXT) SCHEDULE MARK NUMBER SERVICE CAPACITY GALLONS DIAMETER x LENGTH PRESS. PSIG CODE STAMP REMARKS DESIGN GAL. WORK GAL. DESIGN CU. FT. WORK CU. FT. DESIGN WORK EXT -1 CHILLED WATER 44.4 22.2 - - 16 1/4 "DIAx56" 125 20 ASME B &G D -80V (H) HANDICAP P -3 LAVATORY 1 1/2 1 1/2 1/2 1/2 COUNTER TOP RECESSED (H) HANDICAP P -4 MOP SINK AIR SEPARATOR (AS) SCHEDULE MARK NUMBER SYSTEM MAX. CAPACITY GPM OVERALL DIMINSIONS (INCHES) L OUTLET /INLET SIZE/CLASS INLET /OUTLET FACE TO FACE DIM. (INCHES) APPROX. OPERATING WEIGHT (LBS) REMARKS AS -1 CHILLED WATER 90 8 3 /4 "DIAx 17 3/8"H 2 1/2"NPT 9 3/4" 120 B &G R -2 1/2" W /STRAINER 3/4" 3/4" WATTS 009QT INCLUDE AIRGAP DRAIN 1 1/2 - 3/4 WALL -HUNG FLUSH VALVE DOMESTIC WATER BACKFLOW PREVENTER (BFP) SCHEDULE MARK NUMBER LOCATION TYPE CONSTRUCTION CONFIGURATION MANUFACTURER AND MODEL REMARKS BODY INTERNALS INLET OUTLET BFP -1 4TH FLR COL B/14.4 REDUCED PRESSURE BRONZE BRONZE RELIEF S.S. SPRING 3/4" 3/4" WATTS 009QT INCLUDE AIRGAP DRAIN 1 1/2 - 3/4 WALL -HUNG FLUSH VALVE (H) HANDICAP P -3 LAVATORY 1 1/2 1 1/2 AFOFFMAN 4IX FE AS G I N E E R S 1601 Fifth Avenue Suite 900 Seattle, Washington 98101 -1625 206 623 0717 Fax 206 624 3775 PLUMBING FIXTURE CONNECTION SCHEDULE MARK NUMBER DECRIPITION CONNECTION (INCHES) TYPE REMARKS SAN VENT HW CW P -1 WATER CLOSET 4 2 - 1 WALL -HUNG FLUSH VALVE (H) HANDICAP P -2 URINAL 2 1 1/2 - 3/4 WALL -HUNG FLUSH VALVE (H) HANDICAP P -3 LAVATORY 1 1/2 1 1/2 1/2 1/2 COUNTER TOP RECESSED (H) HANDICAP P -4 MOP SINK - - - - FLOOR MOUNTED - P -5 SHOWER - - - - - NOT USED P -5A SHOWER - - - - - NOT USED P -6 ELECTRIC WATER COOLER 1 1/2 1 1/2 - 1/2 WALL HUNG - P -6A ELECTRIC WATER COOLER 1 1/2 1 1/2 - 1/2 WALL HUNG - P -7 BAR SINK 1 1/2 1 1/2 1/2 1/2 COUNTER TOP RECESSED - P -8 SERVICE SINK 3 2 1/2 1/2 WALL HUNG - P -9 EYE -WASH FOUNTAIN - - - 1/2 - - P -9A LAV EYE -WASH - - - - - NOT USED P -10 EYE -WASH AND SAFETY- SHOWER NA - 1 1/4 - W /PRIVACY CURTAIN P -11 FREEZE PROOF EYE WASH AND SAFETY- SHOWER 120 _ _ _ NOT USED P -12 WASH FOUNTAIN - - - - - NOT USED P -12A WASH FOUNTAIN 2 1 1/2 1" 1" SEMI - CIRCULAR - P -12B WASH FOUNTAIN - - - - - NOT USED FD -1 FLOOR DRAIN VARIES VARIES - - 1/2 "TRAP PRIMER (SAN ONLY) SEE PLAN FOR SIZE FFD -1 FUNNEL FLOOR DRAIN VARIES VARIES - - 1/2 "TRAP PRIMER (SAN ONLY) SEE PLAN FOR SIZE FUD -1 FUNNEL DRAIN VARIES VARIES - - 1/2 "TRAP PRIMER (SAN ONLY) SEE PLAN FOR SIZE HUD -1 HUB DRAIN VARIES VARIES - - 1 2 "TRAP PRIM R S N Y S E PLAN FOR SI E FS -1 SANITARY FLOOR SINK VARIES VARIES - - 1/2"TRAP PRIMER (SAN ONLY) SEE PLAN FOR SIZE DOMESTIC HOT WATER HEATER (HwH) SCHEDULE MARK NUMBER INPUT RATING KW TANK STORAGE GALLONS DELIVERY RATE ELEMENTS REMARKS CODE STAMP RECOVERY GPM PHASE NUMBER KW VOLTS 100'F RISE 80T RISE HWH -1 5/3 120 ASME - - 3 2 5/3 208/480 NATIONAL ARGL -120 HWH -2 54 120 ASME 221 277 3 3 18 480 A.O. SMITH DSE -120 HWH -3 1.5 4 - 7 8.3 1 1 1.5 120 A.O. SMITH ELC -4 HWH -4 1.5 4 - 7 8.3 1 1 1.5 120 A.O. SMITH ELC -4 HWH -5 1.5 4 - 7 8.3 1 1 1.5 120 A.O. SMITH ELC -4 HWH -6 1.5 4 - 7 8.3 1 1 1.5 120 A.O. SMITH ELC -4 HWH -7 1'5 4 - 7 8.3 1 1 1.5 120 A.O. SMITH ELC -4 HWH -8 12 80 ASME 49 61 3 1 12 480 A.O. SMITH DSE -80 HWH -9 8 NA - NA NA 1 NA 8 277 CHRONOMITE LABORATORIES MODEL 5 -901 TANKLESS ELECTRIC WATER HEATER HWH -10 9 120 ASME 37 46 3 1 9 240 A.O. SMITH DSE -120 -9 HWH -11 1.5 4 - 7 8.3 1 1 1.5 120 A.O. SMITH ELC -4 HWH-12 1.5 4 - 7 8.3 1 1 1.5 120 A.O. SMITH ELC -4 100% SUBMITTAL ISSUED FOR CONSTRUCTIO REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE RECORD DRAWING (FDS) MJC KW KR 03.31.95 P -8 PHASE 2 — DCN 1 CEI MS 02.24.11 P -8 C— STORE —IFC MS MS 04.21.11 P ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN G. MCCLUNG ChMKED SCHELLPFEFFER ENGINEER SCHELLPFEFFER C ECKED K. WIKSTROM APPROVED K. RAMSEY DATE M(1OSO REVIEWED FOR CODE COMPLIAMof } APPROVED MAY 232011 City of Tukwila BUILDING DIVIsPON a4BFETSIu► APR 2 7 2011 PERMIT CENTER SUBTITLE EQUIPMENT SCHEDULES CURRENT REVISION SYMBOL DATE 04.21.11 07.25.94 APPROVED TITLE P -8 POSEIDON PROJECT, PHASE 2 BUILDING 14 -001 MECHANICAL MASTER THOMPSON. WA SHEET M2E JOB NO. COMP NO. DWG NO. 14- 001 -M2E NMILLER: 01/25/11 16:38 EXHAUST FAN (EF) SCHEDULE MARK NUMBER LOCATION AREA SERVED (ROOM NO.) EXHAUST FAN SECTION REMARKS FAN DIA SIZE MFG. SIZE NUMBER ARRNGMT. NUMBER CFM TOTAL STATIC PRESS. INCHES WG MAX. OUTLET VELOCITY FPM APPROX. RPM DRIVE SIDE INLET GUIDE VANES BHP MOTOR HP VOLTS PH HZ RFI -1 -10 ROOF HIGHBAY - - - 8000 .125 - - - - - 15 460 3 60 - EF -2 ELEV EQUIPMENT RM 106 12.6 SQB -135 - 1145 .25 900 1078 - - - 1/4 120 1 60 ILG EF -3 ROOF EAST RESTROOMS 27 CRB -300 R� NF 5430 .356 1300 490 NA NA - 1.5 480 3 60 ILG W /FACTORY CURB EF -4 ROOF WEST RESTROOMS 1 ST & 2ND FLOORS 27 - ROOF FAN 3660 .625 - - NA NA - 1.0 480 3 60 - EF -5 TELE RM 419 (419) - - CEILING 477 .1 - 1175 - - - 1/10 120 1 60 PACE DD -450G EF -6 LIFT STATION LIFT STATION - 350FT INLINE 350 .1 - 1175 - - - 1/50 120 1 60 PACE DD -350T EF -7 STORAGE ROOM GRID E -10.4 HIGH BAY STORAGE NA CWD -150 WALL FAN 1199 .5 NA 1070 NA NA - 1 /4 120 1 60 ILG WALL FAN, DIRECT DRIVE, WITH GRAVITY BACKDRAFT DAMPER, 7.4 SONES AT 5 FEET. EF -8 PAINT BOOTH GRID D.8 -6 PAINT BOOTH EXHAUST 24 3C411 INLINE 6000 1910 1312 NA NA - 1 208 1 60 DAYTON 3C411 BELT DRIVEN TUBE AXIAL FAN EF -9 WIRE SHOP GRID E -9.4 SOLDERING TABLE NA PWB -245 WALL FAN 2800 .5 NA 675 NA NA - 1/2 480 3 60 ACME WALL FAN, BELT DRIVE, WITH GRAVITY BACKDRAFT DAMPER, 7.4 SONES AT 5 FEET. EF -10 NORTH WALL COL B -13.4 FIRST FLOOR RESTROOM NA 148 WALL FAN 1920 .125 NA - NA NA - 1/4 120 1 60 JENN AIR MODEL 148CW EF -11 ROOF WEST RESTROOM 3RD FLOOR - - ROOF FAN 1700 .25 - - NA NA - 1/3 120 1 60 CARNES ERBA16M4 EF -12 SOUTH WALL COL E -11 FIRST FLOOR CENTER TOILET _ _ ROOF FAN 1920 .125 - - NA NA - 1 4 / 120 1 60 JENN AIR MODEL 148CW EF -13 RACK 27B12 276 MMR RACK 27B12 - COOK GC -640 CEILING 450 .25 - 1075 NA Nq - - 120 1 60 351 WATTS, FAN SHALL OPERATE AT ROOM TEMPS ABOVE 80T EF -14 MMR RACK • . MMR RACK • - - COOK 6, . EILIN II. 450 AIM. Adllb. .25 Adlb■ AIM. Ill. - AMIMIL Adllb■ AMINI■ 1075 AM. AIM. NA AIM. AM& Adlillb. AIM. - AM. - Alai. 120 1 60 351 WATTS, FAN SHALL OPERATE AT ROOM TEMPS , .. ;.• ■ EF -15 KITCHEN 13B13 KITCHEN 13613 _ COOK GN -842 CEILING 900 0.5 - 957 NA NA - 1 /3 120 1 60 WITH FAN SPEED CONTROLLER FOR AIR BALANCING. CONTROL BY CMCS SCHEDULE. EF -16 KITCHEN 13B13 C STORE 19B13 I - COOK GN -740 CEILING 700 .5 0.5 - 1550 NA NA - - 120 1 60 300 WATTS, WITH FAN SPEED CONTROLLER FOR AIR BALANCING. CONTROL BY CMCS SCHEDULE. FAN COIL UNIT SCHEDULE B MARK NUMBER AREA SERVED TYPE NOMINAL CAPACITY TONS FAN COIL COOLING CAPACITY REFRIGERANT TYPE DRAIN SIZE (IN.) ELECTRICAL REMARKS SENSIBLE (BTUH) TOTAL (BTUH) ROOM TEMP MCA FAN MOTOR FLA SPEED CFM MOTOR OUTPUT (WATTS) DB WB FCU -101 DATA 12B8 WALL - MOUNTED 3 MED 810 56 24,400 33,100 78 64 R -410A 5/8 1 0.57 HI NOTES 611 -4PKA -A36KA U- • k dIT 1 FCU -103 KITCHEN 13B13 CASSETTE 3 HIGH 1060 120 23,550 31,150 72 61 R -410A 1-1/4 2 1.00 MITSUBISHI PLA -A36BA NOTES 1 -3, 5 FCU -104 C STORE 19B13 CASSETTE 3 HIGH 1060 120 23,550 31,150 72 61 R -410A 1-1/4 2 1.00 NITS NOTE S S 1 1 - 3, P 5 A36BA 1-3, 5 FCU -105 C STORE 19B13 CASSETTE 3 HIGH 1060 120 23,550 31,150 72 61 R -410A 1 -1 4 / 2 1.00 NITS S 1- P 5 A36BA NOTES 1 -3, 5 FCU -201 DATA 23B8 WALL - MOUNTED 3 MED 810 56 24,400 33,100 78 64 R -410A 5/8 1 0.57 NOTES 1 -4 208 -230 FCU -301 DATA 32B8 WALL- MOUNTED 3 MED 810 56 24,400 33,100 78 64 R -410A 5/8 1 0.57 MITSUBISHI PKA -A36KA NOTES 1 -4 FCU -302 DATA 33B16 WALL - MOUNTED 3 MED 810 56 24,400 33,100 78 64 R -410A 5/8 1 0.57 MITSUBISHI PKA - A36KA NOTES 1 -4 NOTES: 1. WITH FACTORY PROGRAMMABLE THERMOSTAT. 2. FCU WIRING AND DISCONNECT BY ELECTRICAL CONTRACTOR. FCU UNIT POWER SUPPLY FROM CONDENSING UNIT, SEE CONDENSING UNIT SCHEDULE. 3. LOW VOLTAGE CONTROL WIRING BETWEEN FCU AND CU IS BY CONTROLS CONTRACTOR. •; : , ; . :: ; • . , ' 1 : • - ; 0 - . ': , R SUPPLY FROM FCU. INTERLOCK PUMP WITH SAFETY CUT -OFF IN FCU. 5. PROVIDED WITH BUILT -IN -0 CONDENSATE LIFT MECHANISM WITH 22" LIFT CAPACITY /\._ /1/4_ � ' COFFMAN N G I N E E R S 1601 Fifth Avenue Suite 900 Seattle, Washington 98101 -1625 206 623 0717 Fax 206 624 3775 SILENCER (SL) SCHEDULE NUMBER LOCATION SERVICE SIZE IN CFM MAX PRESS DROP INCHES WG PHYSICAL SIZE DIA x L REMARKS SL -1 AQUEOUS CLEANER PF -1 120 480 .05 28" x 36" INDUSTRIAL ACOUSTICS CO MODEL 12FCL36 W /TAILCONE FB01 C SL -2 AQUEOUS CLEANER EF -13 240 6100 .08 40" x 48" INDUSTRIAL ACOUSTICS CO MODEL 24FCL48 W /TAILCONE FBOIC ST -2B AQUEOUS CLEANER P -2B 3" 75 130 CU -103 SARCO S T STEEL STAINLESS S STEEEE ST -2C AQUEOUS CLEANER P -2C 3" 80 130 1 SARCO S T STAINLESS SP STEEL STRAINER (ST) SCHEDULE MARK NUMBER LOCATION SERVICE SIZE (IN) GPM Cv ELECTRICAL REMARKS ST -1B AQUEOUS CLEANER P -1B 3" 75 130 LIQUID (IN) SARCO TYP 527 STAINLESS STEEL ST-1C AQUEOUS CLEANER P -1 C 3" 80 130 208 -230 SARCO TYP 5E7 STAINLESS STEEL ST -2B AQUEOUS CLEANER P -2B 3" 75 130 CU -103 SARCO S T STEEL STAINLESS S STEEEE ST -2C AQUEOUS CLEANER P -2C 3" 80 130 1 SARCO S T STAINLESS SP STEEL ST -3B AQUEOUS CLEANER P -3B 3" 75 130 3 SARCO S T STAINLESS S STEEEE STEEL ST -3C AQUEOUS CLEANER P -3C 3" 80 130 170 SARCO TYP 527 EL STEEL CU -105 C STORE 19B13 OPEN MEZZ 4018 3 14.2 5/8 / 3 8 / 208 -230 CONDENSING UNIT SCHEDULE MARK NUMBER AREA SERVED LOCATION NOMINAL CAPACITY TONS SEER REFRIGERANT PIPING ELECTRICAL WEIGHT (L S) REMARKS VOLTAGE PHASE BREAKER SIZE MCA GAS (IN) LIQUID (IN) CU -101 DATA 12B8 OPEN MEZZ 4006 3 14.0 5/8 3/8 208 -230 1 30 25 170 NOTES MITSUBISHI PUY - A36NHA3 1 . . . • • CU -103 KITCHEN 13B13 OPEN MEZZ 4018 3 14.2 5/8 / 3 8 / 208 -230 1 30 25 170 MITSUBISHI PUY - A36NHA3 NOTES 1 CU -104 C STORE 19B13 OPEN MEZZ 4018 3 14.2 5/8 / 3 8 / 208 -230 1 30 25 170 MITSUBISHI PUY - A36NHA3 NOTES 1 CU -105 C STORE 19B13 OPEN MEZZ 4018 3 14.2 5/8 / 3 8 / 208 -230 1 30 25 170 MITSUBISHI PUY - A36NHA3 NOTES 1 CU -201 DATA 23B8 NoUgPv OPEN MEZZ 4006 NMI NMI 3 NMI 14.0 NMI NMI 5/8 NMI NMI 3/8 NMI NINO/ 208 -230 NMOW NMI/ 1 NMOV 30 NMI NMOPy 25 NRIMPr NMI 170 ∎rIlwMP;s►7-I - NOTES 1 CU -301 DATA 32B8 OPEN MEZZ 4006 3 14.0 5/8 3/8 208 -230 1 30 25 170 NOTES B11H1 PUY - A36NHA3 CU -302 DATA 33B16 OPEN MEZZ 4018 3 14.0 5/8 3/8 208 -230 1 30 25 170 MITSU NOTES B11HI PUY - A36NHA3 NOTES: 1. OUTDOOR UNIT WIRING AND DISCONNECT BY ELECTRICAL CONTRACTOR. SINGLE POINT POWER CONNECTION. POWER WIRING BETWEEN INDOOR AND OUTDOOR UNITS BY ELECTRICAL CONTRACTOR. LOUVER (L) SCHEDULE MARK NUMBER LOCATION SERVICE CFM MAX PRESS DROP INCHES WG PHYSICAL SIZE W X H REMARKS L -1 KITCHEN 13B13 EF -15 & EF -16 1600 0.10 42" X 18" RUSKIN ELF375DX. PROVIDE WITH KYNAR BAKED ENAMEL FINISH, COLOR ASCOT WHITE ( #19). 100% SUBMITTAL ISSUED FOR CONSTRUCTIO SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE RECORD DRAWING (FDS) MJC KW KR 03.31.95 A P -8 PHASE 2 - DCN 1 CEI MS 02.24.11 B P -8 C- STORE -IFC CEI MS 04.21.11 pirOE /NC° ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN G. MCCLUNG CHECKED SCHELLPFEFFER ENGINEER SCHELLPFEFFER CHECKED K. WIKSTROM APPROVED K. RAMSEY DATE M WOsO REVIEWED FOR c CODE COMPLIAN APPROVED r MAY 232Ui( City of Tukwila BUILDING DI'►mir/%! crNOSNALn APR 2 7 2011 PERMIT CENTER SUBTITLE EQUIPMENT SCHEDULES CURRENT REVISION SYMBOL B DATE 04.21.11 07.25.94 APPROVED TITLE P -8 POSEIDON PROJECT, PHASE 2 BUILDING 14 -001 MECHANICAL MASTER THOMPSON, WA SHEET M2F JOB NO. COMP NO. DWG NO. 14- 001 -M2F NMILLER: 01/25/11 16:40 00 CFM 2 �(TYP 7) 14/8 ®12 6 Q FOR RA / / / / / 0 / / \ rr '24/14 RA OPENING ABOVE CEILING 8/10 80 TYP 9 /RA 2 (TTYP) 1 0 14/12 / / / / / / / / / / / 70 / / / 48/14 TRANSFER DUCT 18 12 °O14 12 12/12 78/14 TRANSFER DUCT 0 00 100 LEGEND 1. FOR MECHANICAL LEGENDS AND ABBREVIATIONS SEE SHEETS M1a, M1b AND M1c. GE \ERAL \OTES ITEMS SHOWN AS "LIGHT" LINEWEIGHT ARE EXISTING AND TO REMAIN. ITEMS SHOWN AS "BOLD" LINEWEIGHT ARE NEW, RELOCATED OR REUSED. 41/12 - UP TO 220 REFERENCE DRAWI \GS FIRE DAMPER AT FLOOR PENETRATION 300 CFM (TIP 2) 250 CFM (TYP 2) 088 PARTIAL PLA SCALE: 1/8"=1"-0" VIEW AFOFFMAN 6IX EE FS NGINEERS N E E R S 1601 Fifth Avenue Suite 900 Seattle, Washington 98101 -1625 206 623 0717 Fax 206 624 3775 100% SUBMITTAL SSUED FOR CONSTRUCTIO SYM B REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE REMODEL QA OFFICE J D83P0202 GAVRAS GAVRAS CAD CONVERSION CADDNW C P -8 PHASE 2 — IFC PACKAGE 2 D P -8 PHASE 2 — DCN 1 E P -8 C —STORE —IFC CO CEI CO MS MS 03.02.98 04.22.98 02.13.11 02.24.11 MS 04.21.11 eLA OE /N G' ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN S. LOPER DATE t1w%oso CONSTRUCTIO\ NOTES 112.4 i REVIEWED FOR CODE COMPLIANCE APPROVED MAY 2 3 2011 City of Tukwila BUILDING DIVIsifw KEY PLAN SCALE: NONE 8' 4' 0 4' 8' 16' SCALE: 1 /8 " =1' —O" CITY 0 LA APR 2 7 2011 PERMIT CENTER CHECKED SCHELLPFEFFER ENGINEER SCHELLPFEFFER CHECKED K. WIKSTROM APPROVED K. RAMSEY APPROVED SUBTITLE DUCTWORK CURRENT REVISION SYMBOL DATE E 04.21.11 11:23:26 AM 07.25.94 TITLE P -8 POSEIDON PROGRAM, PHASE 2 BUILDING 14 -001 MECHANICAL MASTER COL.B— C/12.4 -16 THOMPSON, WA SHEET 1M11A JOB NO. COMP NO. DWG NO. 14- 001 -1M11A n I I 1M10A 1M1OB 1M11A 1M118 1M12 1M13 1M14 1M15 1M16 1M17 1M18 1M19 i i REVIEWED FOR CODE COMPLIANCE APPROVED MAY 2 3 2011 City of Tukwila BUILDING DIVIsifw KEY PLAN SCALE: NONE 8' 4' 0 4' 8' 16' SCALE: 1 /8 " =1' —O" CITY 0 LA APR 2 7 2011 PERMIT CENTER CHECKED SCHELLPFEFFER ENGINEER SCHELLPFEFFER CHECKED K. WIKSTROM APPROVED K. RAMSEY APPROVED SUBTITLE DUCTWORK CURRENT REVISION SYMBOL DATE E 04.21.11 11:23:26 AM 07.25.94 TITLE P -8 POSEIDON PROGRAM, PHASE 2 BUILDING 14 -001 MECHANICAL MASTER COL.B— C/12.4 -16 THOMPSON, WA SHEET 1M11A JOB NO. COMP NO. DWG NO. 14- 001 -1M11A MIN CLEARANCE FOR MAINTENANCE 34" 30 "X18" OA LOUVER COFFMAN N G I N E E R S 1601 Fifth Avenue Suite 900 Seattle, Washington 98101 -1625 206 623 0717 Fax 206 624 3775 20/10 DN W /FD...__r___, 14/46 DN W /FD 34 1/2/34 1/2 UP TO EF -3 100% SUBMITTAL ISSUED FOR CONSTRUCTIO REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE CAD CONVERSION CADDNW 04.24.98 P -8 C— STORE —IFC CEI MS 04.21.11 Q�BOE /NG' o�— ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN ADEE CHECKED DATE - -- M 280 LEGE \D 1. FOR MECHANICAL LEGENDS AND ABBREVIATIONS SEE SHEETS Mb, M 1 b AND M 1 c. GE \ERAL \OTES 1. SEE SHEET 1M10 FOR NOTES. REFERE\CE DRAWI \GS CO \STRUCTIO OTES REVIEWED FOR CODE COI II 'LIANOr MAY232011 City of Tukwila BUILDING DIVISION 1 SUBTITLE DUCTWORK KEY PLAN SCALE: NONE CURRENT REVISION SYMBOL A c►TVORNnLA APR 2 7 2011 PERMIT CENTER DATE 04.21.11 ENGINEER CHECKED APPROVED APPROVED TITLE P -8 POSEIDON PROJECT, PHASE 2 MECHANICAL MASTER BUILDING 14 -001 COL. B— C/12.4 -16 THOMPSON, WA SHEET 4M11A JOB NO. COMP NO. DWG NO. 14- 001 -4M11A NMILLER: 01/27/11 15:20 n 4M1OB I 4M11A 4M116 I_____( 1 4M10A SUBTITLE DUCTWORK KEY PLAN SCALE: NONE CURRENT REVISION SYMBOL A c►TVORNnLA APR 2 7 2011 PERMIT CENTER DATE 04.21.11 ENGINEER CHECKED APPROVED APPROVED TITLE P -8 POSEIDON PROJECT, PHASE 2 MECHANICAL MASTER BUILDING 14 -001 COL. B— C/12.4 -16 THOMPSON, WA SHEET 4M11A JOB NO. COMP NO. DWG NO. 14- 001 -4M11A NMILLER: 01/27/11 15:20 • ..... _............ R REMOVE DOOR HEATER MD & ASSOCIATED PIPING .................. 4' CHWS U HWR U • : i ! LEGE\ D 1. FOR MECHANICAL LEGENDS AND ABBREVIATIONS SEE SHEETS M1a, M1b AND M1c. GENERAL \ 2 "HWR 2 "HWS 2" EXP JOINT IN UP POSITION WITH VENT 1 /2 "CHWS 1 1 /2 "CHWR PARTIAL PLA\ VIEW SCALE: 1 /8 " =1' -0" AFOFFMAN � GI Effli G I N E E R S 1601 Fifth Avenue Suite 900 Seattle, Washington 98101 -1625 206 623 0717 Fax 206 624 3775 100% SUBMITTAL ISSUED FOR CONSTRUCTIO SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE CAD CONVERSION CADDNW 04.23.98 A OFFLOAD 7 -127 BUILDING J #993021 -00 MAF TLD 03.18.99 B P -8 PHASE 2 — IFC PACKAGE 2 CEI MS 02.13.11 C P -8 C —STORE —IFC CEI MS 04.21.11 ANFOEFAW® FW 136 2 1/2" EXP JOINT IN UP POSITION TES REFERE \CE DRAWINGS /4 "DRAIN (TYP) 1 1 /2 "CHWR DN 1 1 /2 "CHWS DN t4LIOS° REVIEWED F014- O Gc CODE COMPLIAN APPROVED 2 3 Za11 City of Tukwila BUILDING [)IIIIRIn!' CO \STRUCTIO\ N TES T I I� 1M60A 1M6OB 1M61A 1M61B 1M62 1M63 1M64 1M65 1M66 1M67 1M68 1M69 I KEY PLAN SCALE: NONE crtvRIFIinu► APR 2 7 2011 PERMIT CENTER ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN D. MCCLUNG CHECKED D. MCCLUNG ENGINEER D. MCCLUNG DATE SUBTITLE HVAC PIPING CURRENT REVISION SYMBOL DATE 04.21.11 CHECKED K. WIKSTROM APPROVED K. RAMSEY APPROVED 07.25.94 TITLE P -8 POSEIDON PROGRAM, PHASE 2 MECHANICAL MASTER BUILDING 14 -001 COL. B —C/9.2 -12.4 THOMPSON, WA SHEET 1 M606 JOB NO. COMP NO. DWG NO. 14 -001 -1 M6OB NMILLER: 01/25/11 11:46 'ti.•C.. ., JE`ti'i .... .)(i) F.,..I. ,, _I. :8) PARTIAL PLA\ VIEW SCALE: 1/8"=1'-0" COFFMAN X61X EF0.S N NGINEERS N E E R S 1601 Fifth Avenue Suite 900 Seattle, Washington 98101 -1625 206 623 0717 Fax 206 624 3775 HWR 1 HWS 2 1/2" 2" 100% SUBMITTAL ISSUED FOR CONSTRUCTIO SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE CAD CONVERSION CADDNW 04.23.98 P -8 C— STORE —IFC CEI MS 04.21.11 BOE /NG° ssf 4"CHWR 4 "CHWS U ALIGNMENT GUIDE TYPICAL SEE DETAIL 1 M60A M509 M IOSO • r i REVIOWED FOR CODE COMPLIAMO� t APPROVED MAY 2 3 2011 City of Tukwila BUILDING ma nn' LEGE\ D 1. FOR MECHANICAL LEGENDS AND ABBREVIATIONS SEE SHEETS M1 a, M1 b AND M1 c. SENERAL \OTES 1. SEE SHEET 1M60 FOR NOTES. REFERE\CE DRAWI \GS CO \STRUCTIC N NOTES 1:2.4 KEY PAN SCALE: NONE cmo�ualu+ APR 2 7 2011 PERMIT CENTER ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN D. MCCLUNG CHECKED D. MCCLUNG ENGINEER D. MCCLUNG CHECKED K. WIKSTROM APPROVED K. RAMSEY APPROVED DATE SUBTITLE HVAC PIPING CURRENT REVISION SYMBOL A DATE 04.21.11 07.25.94 TITLE P -8 POSEIDON PROGRAM, PHASE 2 MECHANICAL MASTER BUILDING 14 -001 COL. B— C/12.4 -16 THOMPSON, WA SHEET 1M61A JOB NO. COMP NO. DWG NO. 14 -001 -1M61A NMILLER: 01/25/11 T_/-1 1M616 � 1M60A 1M608 1M61A 1M62 1M63 1M64 1M65 1M66 1M67 1M68 1M69 J KEY PAN SCALE: NONE cmo�ualu+ APR 2 7 2011 PERMIT CENTER ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN D. MCCLUNG CHECKED D. MCCLUNG ENGINEER D. MCCLUNG CHECKED K. WIKSTROM APPROVED K. RAMSEY APPROVED DATE SUBTITLE HVAC PIPING CURRENT REVISION SYMBOL A DATE 04.21.11 07.25.94 TITLE P -8 POSEIDON PROGRAM, PHASE 2 MECHANICAL MASTER BUILDING 14 -001 COL. B— C/12.4 -16 THOMPSON, WA SHEET 1M61A JOB NO. COMP NO. DWG NO. 14 -001 -1M61A NMILLER: 01/25/11 2"HWR 2 "HWS 3 /4 "(TYP IF 3 13 HWR HWS HWR \Mt fI`,I.< PARTIAL PLAN SCALE: 1 /8 " =1' -0" VIEW COFFMAN N G I N E E R S 1601 Fifth Avenue Suite 900 Seattle, Washington 98101 -1625 206 623 0717 Fax 206 624 3775 ..081:3Y 312 4 "CHINS UP 4" CHWR UP "CHWR`° "6N "CHWS DN 2" EXP JOINT (/P'j RAIN FW 229 0:1:N 100% SUBMITTAL ISSUED FOR CONSTRUCTIO il REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE CAD CONVERSION CADDNW 04.23.98 P -8 PHASE 2 — IFC PACKAGE 1 CEI MS 02.06.11 P -8 C —STORE —IFC CEI MS 04.21.11 Q�BOE /NG' ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN D. MCCLUNG CHECKEb D. MCCLUNG ENGINEER D. MCCLUNG CHECKED K. WIKSTROM APPROVED K. RAMSEY APPROVED DATE fTh E , f• LEGE \D 1. FOR MECHANICAL LEGENDS AND ABBREVIATIONS SEE SHEETS M 1 a, M 1 b AND M 1 c. 5/8" GAS & 3/8" LIQ. UP &DN IN WALL (TYP 3) [{ ) R 1 1 /2 "CHWR DN 1 1 /2 "CHWS DN GE \ERAL \OTES REFERENCE DRAWINGS CO \STRUCTIO\ \OTES PROVIDE OIL TRAP AS REQUIRED BY MANUFACTURER. Ilftw05-0 E OPNC C�bCML COMPLIANCE APPROVED MAY 2 s 2011 City of Tukwila BUILDING fIVI!ifN 112.4 T I I---1 2M60A 2M608 2M61A 2M616 1 J SUBTITLE HVAC PIPING KEY PLAN SCALE: NONE CURRENT REVISION SYMBOL crOrRSEn APR 2 7 2011 PERMIT CENTER DATE 04.21.11 07.25.94 TITLE P -8 POSEIDON PROGRAM, PHASE 2 BUILDING 14 -001 COL. B -C/9.2 -12.4 MECHANICAL MASTER THOMPSON, WA SHEET 2M606 JOB NO. COMP NO. DWG NO. 14- 001 -2M60B NMILLER: 01/25/11 12:14 l v. FW 310 E�E ___._._.__...__..l r- 1 f/ I FW ANC OR SEE.I b.ETAIL( 3/4 /VFW \3 14 PARTIAL PLA\ VIEW SCALE: 1/8"H'-0" K)I AFOFFMAN 41XEf G I N E E R S 1601 Fifth Avenue Suite 900 Seattle, Washington 98101 -1625 206 623 0717 Fax 206 624 3775 FW 319 4 "CHW 4 "CHW 4 'CHWR UP & DN 4 "CHWS UP & DN OI NT-�' ' 32� 5/8" GAS & 3/8" LIQ. DN IN WALL (TYP 3) -2" ....EXP JOINT 100% SUBMITTAL ISSUED FOR CONSTRUCTIO II SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE CAD CONVERSION CADDNW 04.23.98 A P -8 PHASE 2 —IFC PACKAGE 1 CEI MS 02.06.11 B P -8 C —STORE —IFC CEI MS 04.21.11 Q1BOE /NG' ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN DATE 1 1 /2 "CHWR UP 1 1 /2 "CHWS UP LEGE\ D 1. FOR MECHANICAL LEGENDS AND ABBREVIATIONS SEE SHEETS M1 a, M1 b AND M1 c. GE \ERAL \OTES REFERE\ CE DRAWI \GS New pi`pibegi sd. 1/ 0.4 GNl�iO S�r't, tvM Ids Ni tLO50 1 REVI AWED FOR CODE COMPLIANG t APPROVED MAY 231ii11 City of Tukwila BUILDING nt ii i w CO\ STRUCTIO\ \OTES 112.4 T - T - T_/-■ 3M60A jiM60B 3M61A 3M61B I KEY PLAN SCALE: NONE crtvEOMILA APR 2 7 2011 PERMIT CENTER CHECKED SUBTITLE HVAC PIPING CURRENT REVISION SYMBOL B DATE 04.21.11 ENGINEER CHECKED APPROVED APPROVED TITLE P -8 POSEIDON PROJECT, PHASE 2 BUILDING 14 -001 MECHANICAL MASTER COL. B -C/9.2 -12.4 THOMPSON, WA SHEET 3M60B JOB NO. COMP NO. DWG NO. 14- 001 -3M60B NMILLER: 01/25/11 14:24 ∎ .� CONNECT TO EXISTING HWR AND HWS MAINS ;�: I !'l r (. )PH { ,35 4. ANCHOR SEE DETAIL gTYP) iI Ij PARTIAL PLA\ VIEW SCALE: 1/8"=1' —0" COFFMAN N G I N E E R S 1601 Fifth Avenue Suite 900 Seattle, Washington 98101 -1625 206 623 0717 Fax 206 624 3775 4 "HWR UP & DN 100% SUBMITTAL ISSUED FOR CONSTRUCTIO 2 "HWS UP & DN 2 "HWR UP 8c DN .,I tit ■ ��oso CODE FOR E COMPLIAMG APPROVED MAY232011 City of Tukwila BUILDING DIVl If N LEGEND 1. FOR MECHANICAL LEGENDS AND ABBREVIATIONS SEE SHEETS M 1 a, M 1 b AND M 1 c. GE \ERAL \OTES REFERE \CE DRAWI \GS CO \STRUCTI3 \ \CTES 112.4 KEY PLAN SCALE: NONE cmo�iuWn�n APR 2 7 2011 PERMIT CENTER O SYM REVISION BY APPROVED DATE 6I7 3M60B 3M61A 3M61B DATE 41'�L Sol, ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED DRAWN —, l CURRENT REVISION SYMBOL B DATE 04.21.11 KEY PLAN SCALE: NONE cmo�iuWn�n APR 2 7 2011 PERMIT CENTER O SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE 41'�L Sol, ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED DRAWN DATE SUBTITLE HVAC PIPING CURRENT REVISION SYMBOL B DATE 04.21.11 Cr s� 6. 4' AV 1 - i0E,AW ® r %� ���j88 1 CHECKED — CAD CONVERSION CADDNW 04.23.98 SHEET 3M61A ENGINEER TITLE P -8 POSEIDON PROJECT, PHASE 2 _ BUILDING 14-001 — — MECHANICAL MASTER COL. B C /12.4 16 THOMPSON, WA A P -8 PHASE 2 — IFC PACKAGE 1 CEI MS 02.06.11 APPROVED BY DEPT. DATE CHECKED B — — R —IFC P 8 C STO E CEI MS 04.21.11 JOB NO. COMP N0. APPROVED APPROVED DWG N0. 14-001-3M61A I i c�,L NMILLER: 01/25/11 14:24 2'" 6" 2" 6" 3" 6" �- w =1 �) W+ W I C) W' Q 3/4 "CHWS 3/4 "CHWR CHWR CHWR CHWS ►— HWS CHWS HWR 3/4 "CHWS 3/4 "CHWR ET 2 1/2" 6" 2 1/2" 6" 3" 6" CHILLER AREA PLAN DETAIL • 2 1/2"CHWS 2 1/2"CHWR COIL PULL NCi - -- c ci ci CI) U = U /AHU\ �33� 2 1/2"X3/4" r I ALIGNMENT GUIDE TYPICAL SEE DETAIL 4M60A M509 PARTIAL P LA \ VIEW SCALE: 1/8"=1' -0" COFFMAN X6IN EERI N NGINEERS N E E R S 1601 Fifth Avenue Suite 900 Seattle, Washington 98101 -1625 206 623 0717 Fax 206 624 3775 3/4" 6" 3/4" 6" 3" 6 "X4 ow— CHWR CHWS :•.'CHWR CHWS HWS 3/4" DRAINS 100% SUBMITTAL ISSUED FOR CONSTRUCTIO SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE CAD CONVERSION CADDNW A P -8 C— STORE —IFC CEI MS 04.27.98 04.21.11 HWR 4 "CHWR 4 "CHWS D �/4" 6" 3/4" 6" 3" N'tw'oo REVIOWED FOR _ . CODE COMPLIAtG1 APPROVED MAY 232011 City of `Tukwila BUILDING DIVISION LEGE \D 1. FOR MECHANICAL LEGENDS AND ABBREVIATIONS SEE SHEETS M1a, M1b AND M1c. GENERAL \OTES 1. SEE SHEET 1M60 FOR NOTES. REFERENCE DRAWINGS CO \STRUCTIO\ \OTES INSTALL WITH RE QUIRED MANUFACTURER CLEARANCES. 1 T n I T_/-1 4M61B _1 4M60A 4M606 4M61A KEY PLAN SCALE: NONE 0 ciTV�Rw APR 212011 PERMIT CENTER ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN MCCLUNG CHECKED ENGINEER DATE SUBTITLE HVAC PIPING CURRENT REVISION SYMBOL DATE A 04.21.11 CHECKED APPROVED APPROVED TITLE P -8 POSEIDON PROJECT, PHASE 2 MECHANICAL MASTER BUILDING 14 -001 COL. B- C/12.4 -16 THOMPSON, WA SHEET 4M61A JOB NO. COMP NO. DWG NO. 14-001-4M61A NMILLER: 01/27/11 15:40 1. FOR MECHANICAL LEGENDS AND ABBREVIATIONS SEE SHEETS M1a, M1b AND M1a. FOR EN BARGED PLAN SEE DETAILS 1M111A11M451 M111A 1M451 SEWAGE LIFT STATION SEE DETAIL /1� ' SAN LIP y-- kk 2N UP ERN_ \OT UGM110AIM506 \IISHED FLOOR EL 116' -0 ". 2. SEE ( fl 1S260 S281 FOR TRENCH DETAILS & FLOOR PATCH. 3. SEE PLUMBING RISERS SHEETS M512 & M513 FOR ADDITIONAL PLUMBING DETAILS. -R- \CE DRAW FOR ENJARGED PLAN SEE DETAILS 1M111A 1M4551M111A 1M455 PARTIAL PLA\ VIEW SCALE: 1 /8 " =1' -0" CO \STRUCTIOf� NOTES ALL FLOOR DRAINS AND FLOOR SINK TRAPS TO BE CONNECTED TO 1 /2 "CW TRAP PRIMER. TYPICAL THROUGHOUT. T - - - Ty-■ UGM11OA UGM1106 UGM111A UGM111B I KEY PLAN SCALE: NONE COFFMAN N G I N E E R S 1601 Fifth Avenue Suite 900 Seattle, Washington 98101 -1625 206 623 0717 Fax 206 624 3775 100% SUBMITTAL ISSUED FOR CONSTRUCTION C1TY OFETUKV'nLA APR 2 7 no i PERMIT CENTER REVISION APPROVED REVISION APPROVED CAD CONVERSION CADDNW 04.23.98 ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED P -8 C— STORE —IFC 04.21.11 APPROVED BY DEPT. DRAWN D. MCCLUNG C ECKED D. MCCLUNG ENGINEER D. MCCLUNG SUBTITLE CURRENT REVISION PLUMBING SYMBOL A 04.21.11 TITLE CHECKED K. WIKSTROM APPROVED K. RAMSEY APPROVED 07.25.94 P -8 POSEIDON PROJECT, PHASE 2 BUILDING 14 -001 SHEET UGM111A JOB NO. COMP NO. MECHANICAL MASTER COL. B— C/12.4 -16 THOMPSON, WA DWG NO. 14- 001 —UGM 111 A 100% SUBMITTAL ISSUED FOR CONSTRUCTIO II 1 FOR GREASE INTERCEPTOR PLUMBING SEE 1M1\ N FOR PLAN ENLARGED DETAILS 1M111A 1M4511M111A 1M451 4 "RWL UP 3/4 "HWH RELIEF VALVE DRAIN DN TO OPEN GRATE BELOW PROVIDE 1 /2 "CW ANGLE VALVE FOR ICE MAKER 3/4 "HWH RELIEF VALVE DRAIN 1 -1/ 3 "FCO 1 -1/4 AK ?"FS— 1I INK 1 " "HW 1 "A �N T0SMP 3 "CW DN 3/4' CW 1 "A 2 "SAN 2"V 3 "CW UP :l 1/2 CW DN TO Prt6 ,& P -7 —7 172" , C 1 "A UP W, BALL VALVE & CAP 3/4 "HWH RELIEF VALVE DRAIN (BELOW SINK) i8 FOR ENLARGED PLAN DETAILS PARTIAL PLAN VIEW SCALE: 1 /8 " =1 " -0 3 � 1M111A 1M4551M111A 1M455 AFOFFMAN GINEERS 1601 Fifth Avenue Suite 900 Seattle, Washington 98101 -1625 206 623 0717 Fax 206 624 3775 SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE CAD CONVERSION CADDNW 04.22.98 A P -8 PHASE 2 — IFC PACKAGE 2 CEI MS 02.13.11 B P -8 C —STORE —IFC CEI MS 04.21.11 pirArEFAW • t4W'OS0 S AF�M��i' VQ:Oalko 4*-z)4 LEGEND 1. FOR MECHANICAL LEGENDS AND ABBREVIATIONS SEE SHEETS M1a, M1b AND M1c. GE \ERAL \OTES REFERE \CE DRAWINGS CONSTRUCTIO\ \OTES PROVIDE NON— ADJUSTABLE TYPE, PRESSURE DROP ACTIVATED, AUTOMATIC TRAP SEAL PRIMER VALVE, ABLE TO ACTIVATE AT A PRESSURE DROP OF 5 -10 PSIG, INTEGRAL VACUUM BREAKER PORTS, 1/2 "COPPER NPT CONNECTIONS. TRAP PRIMER MUST BE IN ACCESSIBLE LOCATION. SEE DETAIL 2/M530 112.4 T - T - 1M111B T_/-1 1M110A 1M110B 1M111A 1M112 1M113 1M114 1M115 -� 1M116 1M117 1M118 1M119 KEY PAN SCALE: NONE O 16' SCALE: 1 /8 "= CITY d TLI LA APR 272011 PERMIT CENTER ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN D. MCCLUNG C-II ECKED SCHELLFPEFFER ENGINEER SCHELLFPEFFER DATE SUBTITLE PLUMBING CURRENT REVISION SYMBOL DATE 04.21.11 CHECKED K. WIKSTROM APPROVED K. RAMSEY 07.25.94 APPROVED TITLE P -8 POSEIDON PROGRAM, PHASE 2 MECHANICAL MASTER BUILDING 14 -001 COL. B— C/12.4 -16 THOMPSON. WA SHEET 1M111A JOB NO. COMP NO. DWG NO. 14- 001 - 1M111A 1/14/2011 11:51:44 AM (3 —WAY THROW) X35 CFM EXHAUST LOUVER PROVIDE BAFFLE PLENUM W /2” INSUL 42x18x36 42x18 SA 50 CFM 13 (TYP 2) HARD ALUMINUM DUCT TO DIFFUSER EF \ 100 20x10 6 f' 28/14 TRANSFER DUCT j, 250 CFM Ki (TYP 2) 120 1 iIi I;f (_) SA 300 CFM 10 (TYP 3) 7 < �> 20/9 .41:"." `\.. , ....I.. 0 (E)CABLE TRAY Y 1 / r r 6 12 a PARTIAL PLA SCALE: 1/4"=1"-0” \ VIEW COFFMAN N G I N E E R S 1601 Fifth Avenue Suite 900 Seattle, Washington 98101 -1625 206 623 0717 Fax 206 624 3775 0 >5 OMENF 100% SUBMITTAL ISSUED FOR CONSTRUCTIO REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE P -8 C— STORE —IFC CEI MS 04.21.11 ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN S. LOPER CHECKED SCHELLPFEFFER ENGINEER SCHELLPFEFFER CHECKED K. WIKSTROM APPROVED K. RAMSEY APPROVED DATE LEGEND 1. FOR MECHANICAL LEGENDS AND ABBREVIATIONS SEE SHEETS M1a, M1b AND M1c. GENERAL NOTES ITEMS SHOWN AS "LIGHT" LINEWEIGHT ARE EXISTING AND TO REMAIN. ITEMS SHOWN AS "BOLD" LINEWEIGHT ARE NEW, RELOCATED OR REUSED. REFERENCE DRAWI \GS CO \STRUCTIO\ \OTES EXISTING CEILING DIFFUSER RELOCATED. PROVIDE NEW BRANCH DUCTWORK AND /OR FLEXIBLE DUCTWORK AS NECESSARY. PROVIDE NEW CEILING DIFFUSER. PROVIDE NEW GRILLE. EXISTING GRILLE RELOCATED. PROVIDE NEW BRANCH DUCTWORK AND VOLUME DAMPER. / CAP EXISTING DUCT. EXISTING TERMINAL UNIT RELOCATED. REBALANCE TO CFM VALUES INDICATED ON THE TERMINAL UNIT SCHEDULE. 8 REBALANCE EXISTING TERMINAL UNIT TO CFM VALUES INDICATED ON THE TERMINAL UNIT SCHEDULE. EXISTING THERMOSTAT RELOCATED. SET TO 707 (ADJ) PROVIDE NEW THERMOSTAT. SET TO 707 (ADJ) PROVIDE NEW SPLIT DX FAN COIL UNIT. M 1%- o smo (ObE OMP ANNE APPROVED j MAY 2 3 2011 City of Tukwila BUILDING fIVIRIfN SUBTITLE DUCTWORK CURRENT REVISION SYMBOL arr�6�ETRIu+ APR 2 7 2011 PERMIT CENTER DATE 04.21.11 07.25.94 TITLE P -8 POSEIDON PROGRAM, PHASE 2 BUILDING 14 -001 COL.B— C/12.4 -16 MECHANICAL MASTER THOMPSON. WA SHEET 1M452 JOB NO. COMP NO. DWG NO. 14-001-1M452 1/14/2011 11:23:26 AM 2"V r 2 "V v CUSTOM SINK (BY OTHERS) �-- 1 -1/2 "V IN WALL SINK (BY OTHERS) REQUIRED TRAP (TYP) r-- 1 -1/2 "V IN WALL ONE —PIECE ESCUTCHEONS (TYP) 1 -1/2 "V 1 -1/2 "W 10-1/2" 2 "W PROVIDE HEAVY DUTY RUBBER NO —HUB CONNECTOR TO GREASE INTERCEPTOR (TYP) GREASE INTERCEPTOR r— 2 "V IN WALL CUSTOM SINK (BY OTHERS) 1 -1/2"V IN WALL --N 1-1/2"V �— 2 "V SINK (BY OTHERS) \ 2 "W TO GREASE INTERCEPTOR INLET PIPE 2 "W LONG RADIUS SWEEP THRU WALL WITH CLEANOUT AND VENT GREASE INTERCEPTOR PLUMBING DETAIL SCALE: NONE P SLEEVE THRU SLAB 1/2" TRAP PRIMER SUPPLY DOMESTIC COLD WATER BRANCH LINE SERVING FLUSH VALVE FIXTURE BALL SHUT —OFF VALVE (N.0.) PRESSURE DIFFERENTIAL AUTOMATIC TRAP PRIMER VALVE DISTRIBUTION UNIT (AS REQ'D) (2 — 4 DRAIN TRAPS) 1/2" TRAP PRIMER LINE FLOOR DRAIN OR FLOOR SINK FLOOR ALL FLOOR DRAINS, EXCEPT FOR SHOWER DRAINS, SHALL HAVE TRAPS PRIMED TYPICAL TRAP SEAL PRIMER SCALE: NONE COFFMAN N G I N E E R S 1601 Fifth Avenue Suite 900 Seattle, Washington 98101 -1625 206 623 0717 Fax 206 624 3775 PROVIDE COPPER DWV PIPING AND FITTINGS FOR ALL EXPOSED WASTE & VENT PIPING (TYPICAL) FLOOR SINK J.R. SMITH SANI — CEPTOR FIG. 3100Y -12 W /NB 1/2 GRATE 100% SUBMITTAL ISSUED FOR CONSTRUCTIO REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE P -8 C— STORE —IFC CEI MS 04.21.11 gLAiralelrivio® b-- ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DRAWN DATE SUBTITLE r SEPARATE PERMIT AND APPROVAL REQUIRED CURRENT REVISION SYMBOL cmaFam.n APR 2 7 2011 PERMIT CENTER DATE CHECKED DETAILS 04.21.11 ENGINEER TITLE DATE P -8 POSEIDON PROJECT, PHASE 2 CHECKED APPROVED BUILDING 14 -001 JOB NO. COMP NO. APPROVED MECHANICAL MASTER THOMPSON, WA DWG NO. 14- 001 -M530