Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M11-054 - BUTTAR & CANTOR LLP
BUTTAR & CANTOR LLP 16600 WEST VALLEY HY M11-054 City (SOTukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206 -431 -2451 Web site: http: / /www.TukwilaWA.gov MECHANICAL PERMIT Parcel No.: 2523049085 Address: 16600 WEST VALLEY HY TUKW Project Name: BUTTAR & CANTOR LLP Permit Number: M11 -054 Issue Date: 05/16/2011 Permit Expires On: 11/12/2011 Owner: Name: AULAKH BUTTAR & CANTOR LLC Address: 16600 WEST VALLEY HWY , TUKWILA WA 98188 Contact Person: Name: RICK OWEN Address: 18318 SE 259 CT , COVINGTON WA 98042 Email: PATRIOTHEATING @MSN.COM Contractor: Name: PATRIOT HEATING & A/C INC Address: 18318 SE 259 CT , COVINGTON WA 98042 Contractor License No: PATRIHA936CN Phone: 253 631 -0601 Phone: 253 631 -0601 Expiration Date: 02/15/2013 DESCRIPTION OF WORK: REPLACE (2) ROOFTOP PACKAGE GAS /ELECTRIC HEATING UNITS. LIKE IN KIND REPLACEMENT IN EXACT SAME SPOT. Value of Mechanical: $10,800.00 Fees Collected: $318.31 Type of Fire Protection: UNKNOWN International Mechanical Code Edition: 2009 Electrical Service Provided by: Permit Center Authorized Signature/ I hereby certify that I have read and examitned this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be compli d with whether specified herein or not. Date: OS lit The granting of this permit does not es e to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of wor I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this permit. Signature: Print Name: Date: /// -/7 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -4/10 M11-054 Printed: 05 -16 -2011 • 0 PERMIT CONDITIONS Permit No. M11 -054 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: AU construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Manufacturers installation instructions shall be available on the job site at the time of inspection. 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). doc: IMC -4/10 M11-054 Printed: 05 -16 -2011 CITY OF TUKWO Community DevelopErnt Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http: / /www. ci. tkwila. wa. us Mechanical Pait No. - o Project No. (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *please print ** SITE LOCATION / King Co Assessor's Tax No.: 2 " �v"1 1 OCK / 46 Site Address: o(, GYi;s9(i%I / /B/ ■'hey Suite Number: /06 Floor: I Tenant Name: /g0)711Go< Ca/2Y'/' New Tenant: ❑ Yes A.. No Property Owners Name: A 7/z K LGr/7 t/J/- Mailing Address: Me,a7 /V86-')l l07 /G/ i9ir7 54/ /tfi /O16 7.- A/iy / /Gi fil/li6/% i,'/ rf- City State Zip CONTACT PERSON — who do we contact when your permit is ready to be issued Name: G/4 `%I //°'% Day Telephone: -, V "DI '/ Mailing Address: jf:W. 9 14/AlY ?f09z City State Zip E -Mail Address: Ar/YO %%jl19G1r //7Nj 'i/7 ,e0'7 Fax Number: 2S3 - X V '6P %9 MECHANICAL CONTRACTOR INFORMATION Company Name: G/�r /Q� // 2'Q77/2 /a /G Mailing Address: 6"'" 5 C 59 G -27/4 J---- Contact Person: E -Mail Address: 40"//0/4147/7, /175/?/ %j2 7 Contractor Registration Number: P/1-rili/it 9s.36 G 1pvl.�j�o�? 4/4, ?OF 2— City State Zip Day Telephone: R3 ,13/— D6D/ Fax Number: AS, 3 - 3x3d - 157/9 Expiration Date: 42-, /S - 27/3 ARCHITECT OF RECORD — All plans must be stamped by architect of record Company Name: Mailing Address: City Contact Person: Day Telephone: Fax Number: E -Mail Address: State Zip ENGINEER OF RECORD — All plans must be stamped by engineer of record Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: State Zip H:\Applications\Forms- Applications On Line\2010 Applications \7 -2010 - Mechanical Permit Application.doc Revised: 7 -2010 bh Page 1 of 2 • Valuation of project (contractor's bid price): $ /19/ flP0 Scope of work (please provide detailed information): 7P T O /Yee)7- 9 ///7 /l` 1, /l'% , /nGV Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement Fuel Type: Electric Gas f� Other: Indicate type of mechanical work being installed and the quantity below: Unit Type: Qty Unit Type: Qty Unit Type: Qty Bioler /Compressor Qty furnace <100k btu 7,..2., air handling unit >10,000 cfin fire damper 0 -3 hp /100,000 btu furnace >100k btu evaporator cooler diffuser 3 -15 hp /500,000 btu floor furnace ventilation fan connected to single duct thermostat 15 -30 hp /1,000,000 btu suspended/wall/floor mounted heater ventilation system wood/gas stove 30 -50 hp /1,750,000 btu appliance vent hood and duct emergency generator 50+ hp /1,750,000 btu repair or addition to heat/refrig/cooling system Incinerator - domestic other mechanical equipment air handling unit <10,000 cfm Q�- �j incinerator - comm/ind PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 international building code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWN R OR AUTHORIZED AGENT: Signature: Date: -3 - J/ Print Name: , f;2 ' OGY, Mailing Address: , J." IDate Application Accepted: Dc Day Telephone: ' 'e3/ 060 tooj % ri City State Zip ll Date Application Expires: L 1 10) (I H:1Application\Forms- Application On Line12010 Applications17 -2010 - Mechanical Permit Application.doc Revised: 7.2010 bh Staff Initials: Nom/ Page 2 of 2 • 40 C City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone : 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 2523049085 Address: 16600 WEST VALLEY HY TUKW Suite No: Applicant: BUTTAR & CANTOR LLP RECEIPT Permit Number: M11 -054 Status: PENDING Applied Date: 05/03/2011 Issue Date: Receipt No.: R11 -00877 Initials: User ID: JEM 1165 Payment Amount: $318.31 Payment Date: 05/03/2011 01:30 PM Balance: $0.00 Payee: PATRIOT HEATING AND A/C INC. TRANSACTION LIST: Type Method Descriptio Amount Payment Check 1568 318.31 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts MECHANICAL - NONRES PLAN CHECK - NONRES 000.322.102.00.00 254.65 000.345.830 63.66 Total: $318.31 doc: Receipt -06 Printed: 05 -03 -2011 INSPECTION RECORD. Retain a copy with permit IN ECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 42" 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 1(-051 e( it r 4 ckt)Tb� Type of-Inspection: n/At, e. J , •A' dress: t(42(acid W L/44-4-ey Date Called: Special Instructions: Q c( 7, 33 -JI ark(' As4F4t 2 P-- i.) j eipt qz e Date Wanted: -7 - Z - f / '-- a.m. p.m. Requester: Phone Co -- (0 - 2S 405 ‘17Asor Approved per applicable codes. CO # ENTS: Corrections required prior to approval. 7 4cfr) /)%ck Date: 7.-/. L /I SPECTION FEE REQUr ED. Prior toxt inspection, fee must be id at 6300 Southcenter Blvtl.. Suite 100. Call to schedule reinspection. .�- �` INSPECTION RECORD t . Retain a copy with permit 127/I-054/ INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: 13 7/I'M & al (1L9Nr7// Type of Inspection: I-- / i//1 L Address- /6 00 t:-rv4' /,ci f/t6 Date Called: 6/ F.). p 1 (vr Ri,'R / Special Instructions: AJ,,,,,,/ Date Wanted: m` Requester: Phone .svo —24/65 . ❑ Approved per applicable codes. Corrections required prior to approval. ('-) COMMENTS: ‘...) 9 ileiv 0 - . );.1 !of 111/ F.). p 1 (vr Ri,'R / i_-/„/„/ / t Nay AJ,,,,,,/ ),1t ,,, ti - , //ye / . Date)._ f iy 7,/,/ nsp�.L� EINS ECTION FEE REQUIRED. Prior to ext inspection, fee must be paid t 6300 Southcenter Blvd., ite 10 . Call to schedule reinspection. • REQUIRED OR IT ❑ Mechanical �/Ciectrical itITPiumbing 1as Piping City of Tukwila DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additi HEET FILE COPY Permit No. 1" Pe' r'view approval is subject to errors and omission. :..;a! of construction documents does not authorize i: of any adopted code or ordinance. Receipt Lpproved Field Copy and contitions is acknowledged: By. Date: City Of lbkwila BUILDING DMSION ECHELONTM SINGLE PACKAGE AIR CONDITIONER GAS /ELECTRIC (13 SEER, R -410A) 2 - 5 TON MODELS: D_YZ024 thru 060 JOB NAME: LOCATION: PURCHASER: ORDER NO: ENGINEER: SUBMITTED TO: FOR: REF: APPROVAL: CONSTRUCTION: SUBMITTED BY: DATE: UNIT DESIGNATION: COOLING PERFORMANCE TOTAL CAPACITY (NET) MBH SENSIBLE CAPACITY (NET) MBH OUTDOOR DESIGN IMP. °F DB /WB TOTAL SUPPLY AIR CFM TEMP. OF AIR ENTERING EVAPORATOR COIL °F DB/WB POWER INPUT REQ. KW (LESS BLOWER MOTOR) HEATING PERFORMANCE GAS FIRED HEAT EXCHANGER INPUT /OUTPUT CAPACITY - - / MBH SUPPLY AIR BLOWER PERFORMANCE TOTAL SUPPLY AIR CFM TOTAL RESISTANCE EXTERNAL TO UNIT IWG BLOWER SPEED (Circle) HI MED LOW MOTOR RATING HP POWER INPUT REQ. WATT ELECTRICAL DATA POWER SUPPLY / / TOTAL UNIT AMPACITY AMPS MINIMUM WIRE SIZE AWG MAX. OVERCURRENT DEVICE FUSES CIRCUIT BREAKER - AMPS UNIT WEIGHT \ OTAL UNIT WEIGHT (operational) - LB� CLEARANCES FRONT 36" BACK 0" LEFT SIDE (FILTER ACCESS) 24" RIGHT SIDE 12" BELOW UNIT 0" \ABOVE UNIT2 36" 1. Units may be installed on combustible floors made from wood or Class A, B or C roof covering material. 2. Units must be installed outdoors. Overhanging struc- tures or shrubs should not obstruct condenser air discharge outlet SCHEDULE NO. MODEL No. DL yz.Fo304/o1va5 STANDARD FEATURES / J J • R -410A Refrigerant. • Low and high pressure switches on all products. • Condenser coils are constructed of Micro - Channel aluminum tube, aluminum fins for long lasting durability and efficient operation. • Evaporator coils are constructed of highly efficient rifled copper tubes with enhanced aluminum fins. • Internal compressor protection (temperature and pressure). _ t.. • Standard cooling operation down to 45° F (Low ambient I4it to REVIEWED FOR available). • Refrigerant system strainer. CODE COMPLIANCE • Single or two stage gas heat. APPROVED • Blow thru heat exchanger design with aluminized steel tub s. MA) . 2 ���� • Induced draft "POST- PURGE" gas control logic. • Reliable spark to pilot ignition. T— Vit • Ignition control provides a red LED for diagnostic error cod ' (�f T 111�a • Compact size cabinet with single footprint. ® CSI u • Bottom and /or side electrical and gas utility connections. DUILDING nIUI�InN • Top discharge condenser air design with flush mounted grille guard. • Full perimeter, removable base rails with built in rigging and shipping provisions. • Heavy gauge galvanized steel cabinet with a paint finish which has industry leading 1000 hour salt spray rating per ASTM -B117 federal test standards. • Easily field convertible from side to bottom discharge. No other accessory needed. • Attractive cabinet design with single piece "watershed" top cover and drip edge to extend cabinet life and deter water collection. • Factory Installed, attractive protection condenser coil grille. • Foil face insulation which does not emit fibers into air stream. • Permanently lubricated condenser and evaporator motors. • Slide out blower assembly with multi speed (5) direct drive motors on all models. • Non corrosive condensate pan internally sloped to meet strict requirements of ASHRAE 62 -89 Indoor Air Quality standard. • Ridged mounted, protected refrigerant access ports externally accessible. • Both numbered and colored wires. • All three phase models have built in filter rack with cleanable filters and 75 VA transformer with resettable circuit breaker. • Warranties on all product applications: • 10 year single phase compressor warranty and 5 or 10" year limited warranty on parts. To qualify for the extended 10 -year parts warranty, the unit must be registered online at www,upgproductregistration.com within 90 days of install. • 5 year 3 phase compressor warranty and 1 year limited warranty on parts. • 20 year gas heat exchanger warranty. NOTE: • A 1" clearance must be provided between any combustible material and the supply air duct work. • The products of combustion must not be allowed to accumulate within a confined space and recirculate. • Refer to the Technical Guide for unit specifications. • Unit may be installed on combustible floors made from wood or class A, B or C roof covering material. • Units must be installed outdoors. Overhanging structures or shrubs should not obstruct air discharge outlet. Johnson Controls Unitary Products 288799 -CSD -D -1009 i1 INSTALLATION LIMITATIONS These units must be installed in accordance with the follow- ing national and local safety codes. 1. National Electrical Code ANSI /NFPS No. 70 or Canadian Electrical Code Part 1, C22.1 (latest editions). 2. National Fuel Gas Code Z223.1 or CSA B149.1 Installa- tion Code. 3. Local gas utility requirements. PRODUCT CATEGORY D = Single Package Air Conditioner PRODUCT GENERATION A = 1st Generation B = 2nd Generation PRODUCT IDENTIFIER Y YP = 13 SEER Gas Heat/Electric VOLTAGE CODE F = 208/230 -1 -60 T = 208/230 -3 -60 W = 460 -3 -60 FIGURE 1 - PRODUCT NOMENCLATURE TABLE 1: UNIT APPLICATION DATA 176230- BIM -A -0206 4. Local plumbing and waste water codes and other appli- cable local codes. Refer to Table 1 for unit application data and to Tables 3 and 4 for gas heat application data. If components are to be added to a unit to meet local codes, they are to be installed at the dealer's and /or the customer's expense. Size of unit for proposed installation should be based on heat loss /heat gain calculations made in accordance with industry recognized procedures identified by the Air Conditioning Contractors of America. 1101 16In10I I51 NOMINAL COOLING CAPACITY (MBH) 024 = 24,000 BTUH 030 = 30,000 BTUH 036 = 36,000 BTUH 042 = 42,000 BTUH 048 = 48,000 BTUH 060 = 60,000 BTUH Voltage Variation Min. / Max.1 208/230V2 187 / 252 460V 575V 432 / 504 540 / 630 Wet Bulb Temperature ( °F) of Air on Evaporator Coil, Min. / Max. 57/72 Dry Bulb Temperature ( °F) of Air on Condenser Coil, Min.3 / Max. 45 / 120 1. Rated in accordance with ARI Standard 110, utilization range "A ". 2. "T1" transformer primary tap must be moved from the 230 volt connection to the 208 volt connection for low voltage applications of 208 volt and below 3. A low ambient accessory is available for operation down to 0 °F. LOCATION Use the following guidelines to select a suitable location for these units. 1. Unit is designed for outdoor installation only. NOMINAL GAS HEATING OUTPUT CAPACITY 045 = 45,000 BTUH 070 = 70,000 BTUH 080 = 80,000 BTUH 090 = 90,000 BTUH 110 = 110,000 BTUH 135 = 135,000 BTUH FACTORY INSTALLED GAS HEAT N = Natural Gas Heat Installed REVIOWED FOR CODE COMPLIANCE APPROVED h1AY 12 2011 2. Condenser must have an unlimited supply of ai a choice of location is possible, position unit o north or east side of building. of Tukwila ING rnVISiflnl AWARNING Excessive exposure of this furnace to contami- nated combustion air may result in equipment damage or personal injury. Typical contaminates include: permanent wave solution, chlorinated washes and cleaners, chlorine based swimming pool chemicals, water softening chemicals, carbon tetrachloride, halogen type refrigerants, cleaning solvents (e.g. perchloroethylene), printing inks, paint removers, varnishes, hydrochloric acid, cements and glues, antistatic fabric softeners for clothes dryers, masonry acid washing materials. 3. For ground level installation, a level pad or slab should be used. The thickness and size of the pad or slab used should meet local codes and unit weight. Do not tie the slab to the building foundation. Unitary Products Group 2i33 1Ma2d 0 co N Table 7: Single Stage Physical Data 508821 - BIM -C -0211 1 Models `■■J. "I"'I MI" DYZ024 `p,y,Z030a'"t DYZ036 DYZ042 DYZ048 DYZ060 Nominal Tonnage 2.0 i2t5 3.0 3.5 4.0 5.0 ARI COOLING PERFORMANCE 51'. Gross Capacity @ ARI A point (Btu) 24.7 '3018 35.6 43.0 50.0 59.5 ARI net capacity (Btu) 24.0 '30,0 34.2 41.5 48.0 57.5 EER 11.6 fi't1'•1' 5 � 11.1 11.6 11.1 10.9 SEER 13.2 :11112 13.2 13.4 13.4 13.0 Nominal CFM 850 '4940 1200 1300 1540 1600 System power (KW) 2.1 IP 3.2 3.6 4.4 5.3 Refrigerant type R -410A R41i0A R -410A R -410A R -410A R -410A Refrigerant charge (lb-oz) 3 -10 Wp. 4 -0 4 -14 4 -4 5 -2 ARI HEATING PERFORMANCE % -° Mz.r Heating model N045 N070 N045-- r;, (V0Z€ N045 N070 N110 N080 N110 N080 N110 N135 N080 N110 N135 Heat input (K Btu) 45 70 45 1)Fpoqi 45 70 90 80 108 80 108 135 80 108 135 Heat output (K Btu) 36 56 36 3'56 36 56 72 64 87 64 87 108 64 87 108 AFUE % 80.0 80.0 80.0( :08010 :.; 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 Steady state efficiency ( %) 80 80 80 . non, 80 80 80 80 80 80 80 80 80 80 80 No. burners 2 3 2 VIM ;r 2 3 4 3 4 3 4 5 3 4 5 No. stages 1 1 1 1 } '. 1 1 1 1 1 1 1 1 1 1 1 Temperature Rise Range ( °F) 25 -55 30 -60 25-55g 1130 6Q1. 25 -55 25 -55 30 -60 25 -55 45 -75 25 -55 35 -65 45 -75 25 -55 35 -65 45 -75 Gas Limit Setting ( °F) 140 160 140 :; t 1,60 140 160 160 150 175 150 175 160 150 175 160 Gas piping connection (in.) 1/2 1'/2. - 1/2 1/2 1/2 1/2 DIMENSIONS (inches) Length 491/8 49'1/8 491/8 491/8 491/8 491/8 Width 471/4 47.314 471/4 471/4 471/4 471/4 Height,.,,,, - -.r, ,s, „ 33 1/2 331/2 33 1/2 41 1/2 41 1/2 41 1/2 1 QP, ERA�TING Abs).:`, . ', ' 437.8 - t:,;.'. j 398 402 460 465 480 COMPRESSORS Type Recip 1 -spd Recip'1 -spd Recip 1 -spd Recip 1 -spd Scroll 1 -spd Scroll 1 -spd Quantity 1 VI: 1 1 1 1 CONDENSER COIL DATA '• • • Face area (Sq. Ft.) 11.9 °.11'.9 11.9 15 15 15 Rows 1 ;',...f 1 1 1 1 Fins per inch 23 14,3 23 23 23 23 Tube diameter (in.) 0.71 / 18 0571 / 18 0.71 / 18 0.71 / 18 0.71 / 18 0.71 / 18 Circuitry Type 2 -pass Micro - Channel EVAPORATOR COIL DATA Face area (Sq. Ft.) 3.4 3:4 3.4 4.4 4.4 4.4 Rows 2 ..:3. 3 3 3 4 Fins per inch 15 . 13 13 16 16 13 Tube diameter 3/8 1/8 3/8 3/8 3/8 3/8 Circuitry Type Interlaced Interlaced Interlaced Interlaced Interlaced Interlaced Refrigerant control Orifice Orifice Orifice Orifice TXV TXV CONDENSER FAN DATA Quantity 1 1• 1 1 1 1 Fan diameter (Inch) 22 22 22 22 22 22 Type Prop Prop Prop Prop Prop Prop Drive type Direct Direct Direct Direct Direct Direct No. speeds 1 1 1 1 1 1 Number of motors 1 1 1 1 1 1 Motor HP each 1/4 1/4 1/4 1/3 1/3 1/2 RPM 1100 1100 1100 1120 1120 1090 Nominal total CFM 2400 2400 2400 3200 3200 3200 DIRECT DRIVE EVAP FAN DATA Quantity 1 1 1 1 1 1 Fan Size (Inch) 10 x 8 10 x 8 11 x 10 11 x 10 11 x 10 11 x 10 Type Centrifugal Centrifugal Centrifugal Centrifugal Centrifugal Centrifugal Motor HP each 1/2 3/4• 3/4 3/4 1 1 RPM Variable Variable Variable Variable Variable Variable Frame size 48 48 48 48 48 48 FILTERS Quantity - Size 1- 20x20x1 11- 20x20x1 1- 20x20x1 2- 20x12x1 2- 20x12x1 2- 20 x 12 x 1 Johnson Controls Unitary Products REVIEWED FOR CODE COMPLIANCE APPROVED MAY 12 2011 City of Tukwila BUILDING rnVISION 13 REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. (NOTE: Revisions will require a new plan submittal and may include additional plan review fees. SEPARATE PERMIT REQUIRED FOR: ❑ Mechanical Electrical l umbing t!TGas Piping City of Tukwila FsU DING DIVISION FILE COPY Pewit No.. tal ( �• OS'1 Plerl review approval is subject to errors and omissions. k2 :: rO f& of construction documents does not authorize th' t. oration of any adopted code or ordinance. Receipt of approved Field Copy and conditions is acknowledged: By Dete: /h -// City Of Tukwila DI ITI I'%T111, F TIJTCTd'1i111 'JOB NAME LOCATION PURCHASER ORDER NO. ENGINEER SUBMITTED TO FOR: Reference Approval Construction SUBMITTED BY DATE IUNIT DESIGNATION: Schedule No. MODEL NO.122 E.0 ©JO PRODUCT DATA COOLING PERFORMANCE TOTAL CAPACITY MBH SENSIBLE CAPACITY MBH OUTDOOR DESIGN .... °F DB/WB TOTAL SUPPLY AIR CFM TEMPERATURE OF AIR ENTERIING EVAPORATOR COIL °F DB/WB POWER INPUT REQUIREMENT (LESS BLOWER MOTOR) KW HEATING PERFORMANCE RESISTANCE HEAT KW CAPACITY MBH VOLTS SUPPLY AIR BLOWER PERFORMANCE TOTAL SUPPLY AIR CFM TOTAL RESISTANCE EXTERNAL TO UNIT IWG BLOWER SPEED (Circle) HI MED LOW MOTOR RATING HP POWER INPUT REQ WATT. ELECTRICAL DATA POWER SUPPLY / / MINIMUM CIRCUIT AMPS AMPS MAXIMUM OVERCURRENT DEVICE ❑ FUSES ❑ CIRCUIT BREAKER . AMPS. UNIT WEIGHT (operating) TOTAL UNIT WEIGHT LBS.. CLEARANCES Front 12" Back 0" Left Side (Filter Access) 24" Right Side 24" Below Unit1 0" Above Unite 36" Units may be installed on combustible floors made from wood or class A, B or C roof covering material. 2 Units must be installed outdoors. Overhanging structures or shrubs should not obstruct condenser air discharge outlet. STANDARD FEATURES • Compact single size cabinet and footprint. • Bottom and or side electrical utility connections. • Top discharge condenser air design with flush mounted grille guard . • Full perimeter, removable base rails with built in rigging and shipping provisions. • Heavy gauge galvanized steel cabinet with paint finish which has industry leading 750 hour salt spray rating per ASTM -B117 federal test standards. • Easily field convertible from side to bottom discharge. No other accessory needed. • Attractive cabinet design with single piece "Water- Shed" top cover and drip edge to deter water collection and increase life. • Factory installed, attractive protection condenser coil grille. • High efficient rifled tube with enhanced fin condenser and evaporator coils. • Foil face insulation which does not emit fibers into airstream. • Permanently lubricated condenser and evaporator motors. • Multi speed (3) direct drive high static motor and slide out blower assembly. • Non corrosive condensate pan internally sloped to meet strict requirements of ASHRAE 62 -89 Indoor Air Quality standard. • Internal compressor protection (temperature and pressure). • Standard cooling operation down to 45° F (Low ambient kit to 0° F available). • Refrigerant system strainer. • Ridged mounted, protected refrigerant access ports externally accessible. • Both numbered and colored wires. • All three phase models have built in filter rack with cleanable filters and 75 VA transformer with re- setable circuit breaker. • 5 year compressor warranty. • 1 year limited warranty on all other parts. • 5 year electric heat element warranty. REVIEWED FOR CODE COMPLIANC E . APPROVED MAY 12 2011 its `"I. City di Tukwila BUILDING DIVISION NOTES; • A 1" clearance must be provided between any combustible material and the supply air ductwork. • Unit may be installed on combustible floors made from wood or class A, B or C roof covering material. • Units must be installed outdoors. Overhanging structures or shrubs should not obstruct condenser air discharge outlet. I � Q rn SINGLE PACKAGE COOLING UNITS (10 SEER) ° i� THRU 5 TON, MODELS D`PB018 THRU 060 w y —• a N FORM 036 - 22435 - 001 -A -0203 Supersedes: Nothing 4641,M14n)104.1 N4 c4I4' n.& 1 SINGLE PACKAGE AIR CONDITIONER GAS /ELECTRIC AIR COOLED Supersedes: 530.30 -N2Y (4831 MODELS D2EC018 THRU D2EC060 GENERAL YORK Model D2EC units are factory assembled cooling/ heating air conditioners designed for outdoor installation on rooftop or a slab. These units offer gas heat combined with electric cooling. The units are completely assembled on a rigid base. All piping, refrigerant charging, and electrical wiring is factory installed and tested. The units require only electric power, gas piping and duct connections at the point of installation. These units shall be installed in accordance with all National and Local Safety Codes. APPROVALS Design certified by A.G.A. as follows: 1. For use as a forced air furnace with cooling unit. 2. For outdoor installation only. 3. For installation on combustible material. 4. For use with. Natural Gas or Propane Gas. Not suitable for use with conventional venting systems. REFERENCE Additional information on the design, installation, operation, and service of this equipment is available in the following reference forms: Tab DEC 530.30 -N2Y (384) 035 - 06085 REVILWED FOR CODE COMPLIANCE A DDROVED MAY 122011 City of Tukwila BUILDING nIVI,SION Form 530.30-N1.3 — Vent Cap Form 530.30 -N1.4 -- L.P. Conversion Kit Renewal Parts: Refer to parts microfiche for additional parts. The above forms may be ordered from: BWCES Publications Distribution Center P.O. Box 1592, York, PA 17405 Installer should pay particular attention to the words: NOTE, CAUTION, and WARNING. NOTES are intended to clarify or make the installation easier. CAUTIONS are given to prevent equipment damage. WARNINGS are given to alert the installer that personal injury and /or equipillCnt damage may result if installation procedures are not handled properly. INSPECTION As soon as a unit is received, it should be inspected for possible damage during transit. If damage is evident, the extent of the damage should be noted on the carrier's freight bill. A separate request for inspection by the carrier's agent should be made in writing. ec o o Aio?066:_ PRODUCT NOMENCLATURE PRODUCT CATEGORY D= Single Package Air Conditioner - Air Cooled PRODUCT GENERATION 1 = NEW or Current Design PRODUCT IDENTIFIER EC = Single Package Air Conditioner cL cs.✓2.vr 31,E �y VOLTAGE CODE 06 = 208/230 -1 -60 25 = 208/230 -3 -60 46 = 460-3-60 FACTORY INSTALLED HEAT N= Natural Gas NOMINAL COOLING CAPACITY 018 = 18,000 Btuh 024 = 24,000 Btuh 030 = 30,000 Btuh 036 = 36,000 Btuh 042 = 42,000 Btuh 048 = 48,000 Btuh 060 = 60,000 Btuh D T PRODUCT CATEGORY D= Single Package Air Conditioner - Air Cooled 2 PRODUCT GENERATION 1 = 1st Generation 2 = New or Current Design PRODUCT NOMENCLATURE E :C PRODUCT IDENTIFIER EC = Single Package Air Conditioner [o 3 6 0 : 6 :0" NOMINAL HEATING CAPACITY 045 = 45 MBH 060 = 60 MBH 080 = 80 MBH 096 = 96 MBH 100 = 100 MBH 140 = 140 MBH VOLTAGE CODE 06 = 208/230 -1 -60 25 = 208/230 -3 -60 46 = 460 -3 -60 FACTORY INSTALLED HEAT N = Natural Gas NOMINAL COOLING CAPACITY 018 = 18,000 Btuh 042 = 42,000 Btuh 024 = 24,000 Btuh 048 = 48,000 Btuh 030 = 30,000 Btuh 060 = 60,000 Btuh 036 = 36,000 Btuh 0 T PRODUCT CATEGORY D= Single Package Air Conditioner - Air Cooled PRODUCT GENERATION 3 = 3rd Generation PRODUCT NOMENCLATURE E PRODUCT IDENTIFIER EC =Sunline Air Conditioner 0i3 6 T NOMINAL HEATING CAPACITY 045 = 45 MBH 060 = 60 MBH 080 = 80 MBH 096 = 96 MBH 100 = 10. MBH 140 40 MBH 0,6;oj FACTORY INSTALLED HEAT N = Natural Gas [0:6 REVIEWED FOR CODE COMPLIANCE APPROVED MAY 12 2011 VOLTAGE C� 06 = 208/230 25 = 208/230 46 = 460 -3 -6C 1-60 otTukwila 3 ILDING nevisION NOMINAL COOLING CAPACITY 024 = 2 TON 042 = 31/2 TON 030 = 21/2 TON 048 = 4 TON 036 = 3 TON 060 = 5 TON NOMINAL HEATING CAPACITY (INPUT) 060 = 60 MBH 080 = 80 MBH 096 = 96 MBH 100 = 100 MBH 140 = 140 MBH -... .. r, .. .,' /.• >... .. ... -..n ..n.. r... •.1,.. .y... ..•.m.. .. ..... i. rxn!. ��. nn.. rv,, r» w.,... �eM: Wr ,..i1ii!'S!f�!`rr1,,_,,,, -. -,^ • TABLE 7 -- HEATING DATA REVIEWED FOR CODE COMPLIANCE APPROVED MAY 12 2011 :- BUILDING nIVl.51��1_._ Nominal Cooling (Tons) - ., ... _ . . Rated Voltage 1feat Input BTUH Certified Rise Range "F Allowable CFM ^ Fan Control ._ Limit Control Gas Sizn. zr; 1.P.S. Max. Min. 1 -1/2 Max.. 45,000t 30 • 60 1042 521 Adjustable _ Preset -Auto 1/2 48.0 1.4 45,000t 30 - 60 1042 521 Adjustable Preset.Auto 1/2 __ 2 54,0 60,000 45 - 75 926 556 Adjustable Preset -Auto 1/2 1 �; ;} s{ .3 60,000 0I 0ti0 45 - 75 _ r aZQ Zitz 926 ° ' 0 ::. 556 1:4: Adjustable c .A41abo• _ . _. Preset -Auto - .. P L r� . ut /2 , ?. . 187 252 60,000 30.60 1389 694 Adjustable Preset -Auto 1/2 3 252 100,000 45 • 75 1543 926 Adjustable Preset-Auto 1/2 414 504 80,000 45 - 75 1234 740 Adjustable Preset -Auto 1/2 3 -1/2 187 100,000 45 - 75 1543 926 Adjustable Preset -Auto 1/2 40A 187 96,000t 30.60 2220 1110 Time 0n•Tirne Off SPDT 1/2 4 60 140,000 45 - 75 2160 1300 Time On -Time Off SPDT 1/2 27.4 35 96,0001 30 - 60 2220 1110 Time On -Time Off SPOT 1/2 5 20 140,000 45 • 75 2160 1300 Time On•Time Off SPDT 1/2 *Heating - to stay with n certified rise range. t Low heat (aerated) models not certified for L.P. gas. TABLE 8 -- ELECTRICAL DATA Cooling (Tons) ., ... _ . . Rated Voltage _.. - Min. Circuit r Ampacity Max. Over- Current #� Protection .. --_.._ Normal Operating U Voltage Range' "" .•4 .. Compressor _ .. Condenser Fan Full Load Amps. ...� .. Evap, Blower Motor F.L. Amps R.L. Amps, L.R. Amps. • Min, Max.. 1-1/2 208/230.1 -60 16.0 25A 187 252 10.0 48.0 1.4 2.1 2 208/230-1-60 19,0 30A 187 252 12.5 54,0 1.4 2.1 2 -1/2 208/230 -1 -60 23,0 35A 187 252 15.5 65.0 1.4 2.1 ' 3 208/230-1-60 27.0 40A 187 252 17.0 75.8 2.2 3.5 208/230-3-60 22.0 30A 187 252 12,6 65,0 2.2 3.5 460.3.60 11.0 16A 414 504 6.3 32.0 1.1 1.8 3 -1 /2 208/230.1 -60 34.0 50A 187 252 22.0 96.0 3.0 3.5 208/230.3.60 26.0 40A 187 252 15.5 82.0 3,0 3.5 4 208/230-1-60 38.4 60 187 252 24.0 114.0 3.5 4.9 208/230-3-60 27.4 35 187 252 15.2 84.0 3.5 4.9 460.3 -60 12.9 20 414 504 7.6 42.0 1.8 1.6 5 208/2.30.1 -60 47.0 60 187 252 29.0 125.0 3.5 6.9 s.,_.--___ 208/230 -3.60 33.0 45 187 252 18.0 90.0 3.5 6.9 460 -3 -60 15.0 20 414 504 9.0 45.0 1.8 1.6 R.L. = Rated Load, L.R. = Locked Rotor, 1=,L, = Full Load *Field connections must he sized for copper wire only. '''Dual Element Fuse or HACR Circuit Breaker. """'' Utilization Range "A" in accordance with ARI Standard 110, NAT. C, 0046' 410./..78 ?J'Ic' w^cY/Vr i=S• C/4 q f /i",4 Me eM v7"S ef41 /7'.VA/600/k,47-6 ‚‚/&r - A/O 7:0704 NORMAL MAINTENANCE CAUTION: Prior to any of the following main- tenance procedures, shut off all power to the unit, or personal injw y could result. Periodic maintenance normally required consists of changing or cleaning filters, lubricating the blower and evaporator motors, and, under some conditions, cleaning the plain burners. FILTERS Inspect once a month, Replace Disposable or clean Permanent Type as necessary. DO NOT replace Permanent "Cype with Disposable. MOTORS - Blower and Fan lvlot.ors with sleeve bearings and oilers should be oiled annually with. SAE 10 or 20 weight oil. Use only 20 -30 drops -- DO NOT OVER OIL. Borg - Warner Central Environmental Systems Inc. The blower motor is shipped with an oil supply which will last, under normal operating conditions, for Several years. After this time it should be oiled annually with 100 drops (approximately 5 cc) of SAE 20 oil with an. SJ.) orSl. rating in each bearing. CAUTION: DO NOT over- lubricate motor. BURNER & PILOT --- Periodically -at least. annually at thc beginning of each heating season -make a visual check of the pilot and main burner flame and if necessary adjust main burner primary air shutters to give a distinct, sharp blue flame as explained under "BURNER AIR SHUTTER ADJUSTMENT." If it is not possible to adjust for the proper flame, the burners May need cleaning. TO CLEAN BURNERS: Remove then) from the furnace as explained in "Burner Instructions." Clean burners with hot water applied along top of the burrlcr. • �il.� l.. . it•• r '11 TABLE 2 --- AIR TEMPERATURE Unit Nominal Cooling - Tons Air Temp. -- ° F On Evaporator On Condenser Min. WB Max. WB Min. DB Max. DB 1- 1/2thru3 -1/2 4 &5 67 57* 72 72 55 45* 115 115 TABLE 3 -- EXTERNAL STATIC PRESSURE External Static Pressures (Maximum) 1-1/2 th ru 3-1/2 Ton 4 &5Ton .5" W.C. 1 "W.C. LOCATION Use the following guidelines to select a suitable location for these units. 1. Unit is designed for outdoor installation only. 2. Condenser must have an unlimited supply of air and, where a choice of location is possible, position unit on either north or east side of building. 3. For ground level installation, use a 4 -inch minimum . thick concrete, level slab, at least 6 inches wider and longer than unit casing. Do not tie slab to building foundation. 4. For rooftop installation, be sure structure will support a weight of at least 40 pounds per square foot. Unit must be installed on a solid level platform or appro- priate angle iron frame. CLEARANCES All units require certain clearances for proper operation and service. Clearances below are those required for com- bustable construction, for servicing, and for proper unit operation: Duct. Panel Condenser Inlet Side Burner Access Side Blower Access Compressor Access Top Bottom Vent Cap -- 6" Minimum — 36" Min. (1 -1/2 - 3 -1/2 Ton) 24" Min. (4 & 5 Ton) --- 24" Minimum — 24" 24" — No obstruction _. Combustible material — 14" Minimum WARNING: Do not permit overhanging structures or shrubs to obstruct condenser stir discharge outlet or combustion air inlet. Borg - Warner Central Environmental Systems Inc. C REVIEWED FOR ODE COMPLIANCE APPROVED MAY 12 2011 CityofTukwi1a BUILDING DIVIL N RIGGING OR HANDLING Care must be taken when moving the unit to the place of installation. Do not remove any crating until the unit is near the place of installation. Rig unit by attaching chain Or cable slings to the holes or lifting Tugs provided on the base rail. Spreaders, whose length exceeds the largest dimension across the unit, should be used across the top of the unit. On units which have skids attached, the slings should he placed around the bottom skid. BEFORE LIFTING A UNIT, MAKE SURE THAT ITS WEIGHT IS DISTRIBUTED EQUALLY ON THE CABLES SO THAT IT WILL LIFT EVENLY. TABLE 4 — UNIT WEIGHTS rs Approx. Nomi aI Cooling (Tons) Shipping 11/2 2 2 %a 3 31/2 4 5 Wt. /Lbs. 280 300 325 420 427 829 845 DUCTWORK Ductwork should be designed and sized according to the methods of the Air Conditioning Contractors of America (ACCA), as set forth in their Manual K. A closed return duct system shall be used. This shall not preclude use of economizers or outdoor fresh air intake. It is recommended supply and return duct connections at the unit be made with flexible joints to minimize noise. CAUTION: When fastening return air duct to return air inlet, insert screws through one- inch. flanges 0111)'. DO NOT insert screws through casing. Outdoor ductwork must be insulated and watcrproo./ed. FILTERS Filters must always be used ahead of evaporator coil and must be kept clean or replaced with. same size and type. Dirty filters will reduce capacity and will result in frosted coils or safety shutdown. Minimum filter area for disposal type is given in the specification sheet for the specific unit. Filters must be furnished and installed locally unless filter frame assembly is obtained as an optional item. CONDENSATE DRAIN Plumbing must conform to local codes. Use a sealing compound on male pipe threads. Install the condensate drain line (3/4" IPS or 5/8" ID tubing) to spill into an open drain. NOTE: The condensate drain line should be trapped to provide proper drainage. 3 *PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M11 -054 DATE: 05/03/11 PROJECT NAME: BUTTAR & CANTOR LP SITE ADDRESS: 16600 WEST VALLEY HY X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: � \ 4din 'vision J Public Works OgVFire Prevention ❑ Structural Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete IA Comments: Incomplete ❑ DUE DATE: 05/05/11 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route Il REVIEWER'S INITIALS: Structural Review Required ❑ No further Review Required DATE: APPROVALS OR CORRECTIONS: DUE DATE: 06/02/11 Approved ❑ Approved with Conditions 1J Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 Contractors or Tradespeople Peter Friendly Page • General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name PATRIOT HEATING & A/C INC Phone 2536310601 Address 18318 Se 259Th Ct Suite /Apt. City Covington State WA Zip 980425052 County King Business Type Corporation Parent Company UBI No. 602686888 Status Active License No. PATRIHA936CN License Type Construction Contractor Effective Date 2/15/2007 Expiration Date Suspend Date Specialty 1 2/15/2013 Heating /Vent /Air - Conditioning And Refrig (Hvac /R) Specialty 2 Unused Business Owner Information Name Role Effective Date Expiration Date OWEN, RICK JAMES President 02/15/2007 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 WESTERN SURETY CO 70240444 02/01/2007 Until Cancelled $6,000.00 02/15/2007 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 2 TRUCK INS EXCHANGE 035140503 02/09/2011 02/09/2012 19.28.041 RCW ELECTRICAL CITATION $1,000,000.00 01/04/2011 1 FARMERS INS EXCHANGE 035140503 02/09/2007 02/09/2011 $1,000,000.00 02/15/2010 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period Infractions /Citations Information Infraction / Citation Date RCW Code Type Status Violation Amount ENESM00352 4/11/2011 19.28.101 RCW ELECTRICAL CITATION Satisfied $250.00 ENESM00351 4/11/2011 19.28.041 RCW ELECTRICAL CITATION Satisfied $500.00 https: // fortress .wa.gov /lni /bbip /Print.aspx 05/16/2011