HomeMy WebLinkAboutPermit M11-056 - SAFEWORKSSAFEWORKS 365 UPLAND DR EXPIRED I1 -09 -11 Mi 1 -056 City oilkukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206 -431 -2451 Web site: http: / /www.TukwilaWA.gov MECHANICAL PERMIT Parcel No.: 8836500070 Address: 365 UPLAND DR TUKW Project Name: SAFEWORKS Permit Number: M11 -056 Issue Date: 05/13/2011 Permit Expires On: 11/09/2011 Owner: Name: TRIPLE H DEVELOPMENT LLC Address: 1006 SPRAGUE ST , EDMONDS WA 98020 Contact Person: Name: KELVIN BATTLE Address: 25500 74 AV S , KENT WA 98032 Email: KELVIN @PMGHVAC.COM Contractor: Name: PERFORMANCE HEATING Address: 7649 S 180 ST , KENT WA 98032 Contractor License No: PERFOHA150RT Phone: 425 - 251 -0356 Phone: 425 251 -0356 Expiration Date: 04/30/2013 DESCRIPTION OF WORK: REPLACE EXISTING FAILED MITSUBISHI SPLIT SYSTEM WITH NEW. SAME SIZE AND SAME LOCATION AS EXISTING TO SERVE SERVER ROOM. Value of Mechanical: $6,800.00 Type of Fire Protection: UNKNOWN Electrical Service Provided by: Permit Center Authorized Signature: Fees Collected: $269.31 International Mechanical Code Edition: 2009 Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this permit. Signature: Print Name: Date: J // This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -4/10 M11-056 Printed: 05 -13 -2011 PERMIT CONDITIONS Permit No. M11 -056 1: ** *BUILDING DEPARTMENT CONDmONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431- 3670). 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IMC-4/10 M11 -056 Printed: 05 -13 -2011 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Building Permit No. Mechanical Permit No. tI( (1— OS 4 Plumbing /Gas Permit No. Public Works Permit No. Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION King Co Assessor's Tax No.: 2613200133 S(�'ij(asp— 077o Site Address: 365 Upland Drive Tukwila Wa 98188 Tenant Name: Safeworks Suite Number: Property Owners Name: Triple H Development LLC Mailing Address: 1006 Sprague St Edmonds Server room New Tenant: ❑ Yes [4..No Wa 98020 City State Zip CONTACT PERSON - who do we contact when your permit is ready to be issued Name: Kelvin Battle Day Telephone: 425- 251 -0356 Mailing Address:25500 74th Ave S Kent, WA City State E -Mail Address: kelvin @pmghvac.com Fax Number:253- 867 -5775 98032 Zip GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: Performance Heating & Air Conditioning Mailing Address: 25500 74th Ave S Kent, WA City State Contact Person: Kelvin Battle Day Telephone: 425 -251 -0356 E -Mail Address: kelvin @pmghvac.com Fax Number: 253 -867 -5775 Contractor Registration Number: PERFOHA 15ORT Expiration Date: 98032 Zip 4/30/12 ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: city Contact Person: Day Telephone: E -Mail Address: Fax Number: Q `, Applications \Forms- Applications On Lme 3 -2006 - Permit Application doc Revised- 9 -2006 bh State Zip Page 1 of 6 MECHANICAL PERMIT INFORMATION - 206 - 431 -3670 MECHANICAL CONTRACTOR INFORMATION Company Name: Performance Heating and Air Conditioning Mailing Address: 25500 74th Ave S Contact Person: Kelvin Battle E -Mail Address: kelvin @pmghvac.com Contractor Registration Number:PERFOHA 15ORT Kent WA City State Day Telephone: 425- 2581 -0356 Fax Number: 253-867-5775 Expration Date: 4/30/14 98032 Zip Valuation of Mechanical work (contractor's bid price): $ 6.800.00 Scope of Work (please provide detailed information): Replace existing failed Mitsubishi split system with new. Same size and same location as existing to serve Server Rm. Use: Residential: New .... ❑ Replacem ent .... ❑ Com mercial: New .... ❑ Replacem ent .... Fuel Type: Electric x ❑ Gas ....❑ Oth er: Indicate type of mechanical work being installed and the quantity below: Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace <100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100.000 BTU Furnace >100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1.000.000 BT11 Suspended /Wall /Floor Mounted Heater Ventilation System Wood /Gas Stove 30 -50 HP /1.750.000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat /Refrig /Cooling System Incinerator - Domestic Other Mechanical Equipment 1 Cooling only split system Air Handling Unit <10.000 CFM Incinerator — Comm /Ind Q.AApplications \Forms - Applications On Line A3 -2006 - Permit Application. doe Revised 9 -2006 hh Page 4 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction – In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review – Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Date: 5/3/2011 Print Name: Kelvin Battle D ay Telephone: 425 -251 -0356 Mailing Address: 25500 74th Ave S Kent City WA 98032 State Zip Date Application Accepted: Date Application Expires: r. 1— 14-4/ Staff Initials: j � /f Q- \Applications \Forms - Applications On Line \3-2006 - Permit Application. doc Revised- 9-2006 bit Page 6 of 6 • City of Tukwila r�Z Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: //www. ci. tukwi la. wa. us Parcel No.: 8836500070 Address: 365 UPLAND DR TUKW Suite No: Applicant: SAFEWORKS RECEIPT Permit Number: M11 -0S6 Status: PENDING Applied Date: 05/04/2011 Issue Date: Receipt No.: R11 -00895 Initials: User ID: WER 1655 Payment Amount: $269.31 Payment Date: 05/04/2011 02:22 PM Balance: $0.00 Payee: PERFORMANCE HEATING & A/C TRANSACTION LIST: Type Method Descriptio Amount Payment Check 52107 269.31 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts MECHANICAL - NONRES PLAN CHECK - NONRES 000.322.102.00.00 215.45 000.345.830 53.86 Total: $269.31 doc: Receiot -06 Printed: 05 -04 -2011 mtMITSUBISHI ELECTRIC HVAC Advanced Products Division t4t 05(0 FILE enrol F r. SLLII Split - ductless A/C and Heat Pumps SUBMITTAL DATA: PCA - A24KA4 flk PUY - A24NHA4 24, 000BTU/ H CEILING-SUSPENDED AIR -CONDITIONINGSYSTEM Job Name: S wl�rr'C ,Strve Location: Date: Purchaser: Engineer: Submitted to: For ❑ Reference ['Approval ['Construction Unit Designation: Schedule No.: GENERAL FEATURES • Ceiling- suspended indoor unit for residential and commercial applications • Shiny white cabinet; compact design • Standard air filter is included with indoor unit; high - efficiency filter is available as an option • Setback down to 50 °F when used with MRCH1 Central Controller • Quiet operation —both indoor and outdoor units • Self -check function— integrated diagnostics • Limited prey: five years on parts ariiae lG V on compressors OPTIONAL ACCESSORIES CO ®E COMPLI Indoor Unit o Mini Condensate Pump (PAC- SH84DM, 230V) ® j lr- o High - efficiency Filter (PAC- SH89KF) PA o i -see Sensor with Mount (PAC -SH9101 -E) Outdoor Unit o Drain Pan (PAC- SG64DP) o Drain Socket (PAC -SG61 DS) o Three-pole Disconnect Switch (TAZ -MS o Wind Baffle (\NB -PA2) o Air Outlet Guide (PAC- SG59SG) o Mounting Base (DSD -400N) o Mounting Pad (ULTRILITE2) o Wall- mounting Brackets (CWMB1) Controller Options o Wireless Remote Controller Kit (MHK1) with Wall- mounted Central Controller (MRCH1), Wireless Receiver (MIFH1), and cable` o Wall- mounted Central Controller (MRCH1)' o Wireless Receiver (MIFH1)* o Portable Central Controller (MCCH1; for use with Wireless Remote Controller Kit MHK1)' o Outdoor Air Sensor (MOS1; for use with Central Controller (MRCH1), Wireless Remote Controller Kit (MHK1) and Portable Central Controller (MCCH1)` 'See Submittal for information on each option. 3 OR co MAY 052Q1 City ofTu BUILDING nn o Wall- mounted Wired Remote Controller (PAR -21 MAA) o M -NET Adapter (PAC -SF81 MA) o CN51 Connector for Multiple Remote Controller Adapters /Duct Fan Controller (PAC- 725AD) o CN32 Connector for Remote On/Off (PAC- 715AD) o Remote Temperature Sensor (PAC-SE41TS) o Remote Operation Adapter - Display and On/Off (PAC- SF4ORM) o Wireless Remote Controller Kit (PAR- SL93B) o i -See Sensor and Wireless Remote Controller Kit (PAR- SA92MW) o Lockdown Bracket for Handheld Controller (RCMKP1CB) o ControUService Tool (PAC- SK52ST) Cooling* Rated Capacity 24,000 Btu /h Minimum Capacity 12,000 Btu /h SEER 16.8 Btu /h/W EER 10.3 Btu /h/W Total Input 2,340 W * Rating Conditions (Cooling) - Indoor: 80°F (27 °C) DB / 67 °F (19°C) WB. Outdoor: 95 °F (35 °C) DB / 75 °F (24 °C) WB. Electrical Requirements Power Supply 208 / 230V, 1- Phase, 60 Hz Recommended Fuse /Breaker Size .25 A Voltage Indoor - Outdoor S1 -S2 AC 208 / 230V Indoor - Outdoor S2 -S3 DC 24V OPERATING CONDITIONS With optional wind baffle accessory installed. If not installed, the minimum emperature will be 23 °F ( -5 °C) DB. Indoor Unit: PCA - A24KA4 Indoor Unit MCA Fan Motor ji6an Motor Output ii airflow (Lo - Mid1 - Mid2 - Hi) Outdoor Unit: PUY - A24NHA4 1A 0 54 F.L.A. 95 W 530 - 565 - 600 - 670 Dry CFM 495 - 530 - 565 - 635 Wet CFM �r Polypropylene Honeycomb Sound Pressure Level (Lo - Midi - Mid2 - Hi) 33 - 35 - 37 - 40 dB(A) SHF 0.73 Moisture Removal 5 8 pt. /h DIMENSIONS Indoor Intake Air Temp. Outdoor Intake Air Temp. Maximum 95°F (35°C) DB, 71°F (22°C) WS 115 °F (46°C) DB Cooling Minimum 67°F (19°C) DB, 57°F (14°C) WB 0°F** (-18°C) DB With optional wind baffle accessory installed. If not installed, the minimum emperature will be 23 °F ( -5 °C) DB. Indoor Unit: PCA - A24KA4 Indoor Unit MCA Fan Motor ji6an Motor Output ii airflow (Lo - Mid1 - Mid2 - Hi) Outdoor Unit: PUY - A24NHA4 1A 0 54 F.L.A. 95 W 530 - 565 - 600 - 670 Dry CFM 495 - 530 - 565 - 635 Wet CFM �r Polypropylene Honeycomb Sound Pressure Level (Lo - Midi - Mid2 - Hi) 33 - 35 - 37 - 40 dB(A) SHF 0.73 Moisture Removal 5 8 pt. /h DIMENSIONS UNIT INCHES / MM W 50 -3/8 / 1,280 D 26 -3/4 / 680 H 9-1/16 / 230 Weight 71 lbs. / 32 kg External Finish Munsell No. 6.4Y 8.9 / 0.4 Field Drainpipe Size O.D. 1- 1/16" / 26 mm Outdoor Unit Compressor DC Inverter - driven Twin Rotary MCA . 18 A MOCP 30 A Fan Motor 0 75 F.L.A. Sound Pressure Level Cooling .48 dB(A) DIMENSIONS INCHES / MM W 37 -3/8 / 950 D 13 + 1 -3/16 /330 + 30 H 37 -1/8 / 943 Weight External Finish Refrigerant Type Refrigerant Pipe Size O.D. Gas Side Liquid Side Max. Refrigerant Pipe Length Max. Refrigerant Pipe Height Difference Co . - n ethod EWED 163 lbs. / 74 kg Munsell No. 3Y 7.8/ 1.1 R410A MAY 04 2011 T I 5/8 "/15.88mm 3/8" / 9.52 mm 165'/50m 100'/30m Flared [FRONT VIEW LOOKING THROUGH THE UNIT] Electrical box © 0 10-1/4(260) 0 1�d Citirt i1I nn a4 1f11 -12 36 /S.t.f/S4SZS(. Ceiling !6(6CLfLlL /8/ 2 -15/16 7 3- 3/8(86) 1/16(2) [BACK VIEW] 18 1/8 461) 15-1/4(387) When electrical box 'spoiled down Electrical box If the piping is installed in the back of the unit, remove the shaded portions from the component at right. Then, reinstall the component in its original position (the heat exchanger might be dogged beause of dust. 5/1.8 1 -7 0 0 0 0 0 0 0 0 93/1 9-11/ When drain socket is installed Drainage Incase of wireless remote centroter and kee sensor (Optional Paris) Drainage pipe connection(1 "[26mm] I.D) Drainage pipe connection(for the left arrangement) Knockout hole for left drain- piping arrangement Refrigerant -pipe connection(gas pipe sidelflared connection) Refrigerant -pipe connection(liquid pipe side /flared connection) Knockout hole for upper drain pipe arrangement Knockout hole for ventilation air intake 03- 15116(0100) Knockout hole for wiring arrangement 0718(022) Accessory...Drain socket (1" [26mm] I.D.) In case of wireless remote controller and i -see sensor(Optional Parts) Emergency operation switch <Cood ,c switch <Hee/ .> Emergency operation im term Receha DEFROST/SAM BYbry Irrro squid 0318(09.52) gas 5518(01518) When dram soda e mated Drainage NOTES. 1.Use M10 or W3/8 screw for anchor bolt. 2.Please be sure when installing the drain lift mechanism(option parts),refrigerant pipe will be only upward. (ww) you! :mun m cn O cn -D ) NA —D ZV -v3d - dS 0 KA4 - PUY- A24NHA4 - 201011 @ MITSUBISHI ELECTRIC / HVAC 2010 1 FREE SPACE (Around the unit) The diagram below shows a basic example. Explantion of particular details are given in the installation manuals etc. Chin. tOmm, <3/8, 13 2 SERVICE SPACE 3 FOUNDATION BOLTS Dimensions of space needed Please secure the unit firmly for service access are with 4 foundation (M10<W3/8>) shown in the below diagram. bolts. (Bolts and washers must be purchased locally.) C Min. 500mm 09 -1516> 11 C Mm, 100mm 0115116, Example of Notes 5)--Refrigerant GAS pipe connction (FLARE) 115.88'578' CO—Refrigerant LIQUID pipe connection {FLARE)oS 9.5203/80 '1 —Indication of STOP VALVE connection location. Art Intake Piping Knockout Hole Details 4 PIPING - WIRING DIRECTIONS Piping and wiring connections can be made from 4 directions: front, right, rear and below. <Foundation bolt height> Rear Ai Intake Do:Whole Side Air Intake Handle Handle t kir .0000. Side Air Intake When installing the conduiL Set the attachment to the inner side of each panel. I Rear Air Intake 2-U Shaped notched 9010 Foundfakon Bdl M10<M718> 175 4-71, - 600 <23 -5/80 17 Disdarge 6602 -MB> 101 V 2 -12"76 Oval M o a Foundation Bolt M1001V3/8 -VHNPZV-Afld :SNOISIONI KELVIN BATTLE 25500 74 AV S KENT WA 98032 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director RE: Permit No. M11 -056 SAFEWORKS 365 UPLAND DR TUKW Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 11/09/2011. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 11/09/2011, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician ,,ig -4, File: Permit File No. M11 -056 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 • t CAP PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M11 -056 PROJECT NAME: SAFEWORKS SITE ADDRESS: 365 UPLAND DR X Original Plan Submittal _ Response to Correction Letter # _ DATE: 05 -04 -11 Response to Incomplete Letter # Revision # After Permit Issued D PARTMENTS: Cc.' ui ding Division Public Works 5155' 1t Cg't� Fire Prey ntion Structural ❑ Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete DUE DATE: 05-05-11 Not Applicable n Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route n Structural Review Required ❑ No further Review Required M REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 06-02-11 Approved ❑ Approved with Conditions A Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 Contractors or Tradespeople enter Friendly Page • Page 1 of 1 General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name PERFORMANCE HEATING & A/C INC UBI No. 600601386 Phone 4252510356 Status Active Address 25500 74Th Ave 5 License No. PERFOHA15ORT Suite /Apt. License Type Construction Contractor City Kent Effective Date 12/30/1985 State WA Expiration Date 4/30/2013 Zip 98032 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Business Owner Information Name Role Effective Date Expiration Date MILLER, DANIEL E President 11/27/2007 Bond Amount ERDAHL, DARRIN Vice President 11/27/2007 748802C GOWIN, RICHARD L Vice President 01/01/1980 04/26/2011 GOWIN, CONSTANCE F Vice President 01/01/1980 11/15/2007 Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 10 DEVELOPERS SURETY & INDEM CO 748802C 10/01 /2007 Until Cancelled $12,000.0011/27 /2007 9 DEVELOPERS SURETY & INDEM CO 853803C 04/28/2002 Until Cancelled 12/24/2007 $12,000.0004/23 /2002 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 20 Ohio Caslns Co BKA54440798 04/28/2011 04/28/2012 $1,000,000.00 04 /26/2011 19 OOHIO CAS INS BKA54440798 04/28/2010 04/28/2011 $1,000,000.00 04/27/2010 18 OHIO CAS INS BK00853621857 04/28/2007 04/28/2010 $1,000,000.0004 /22/2009 17 BURLINGTON INS CO HGL0012730 04/28/2006 04/28/2008 $1,000,000.00 04/24/2007 16 BURLINGTON INS CO HGL00006025 04/28/2005 04/28/2006 $1,000,000.00 04/27/2005 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https://fortress.wa.gov/lni/bbip/Print.aspx 05/13/2011 ±90' -0' UPLAND DR NORTH It -H CU -1 48dB(a) SOUTH ft. SITE PLAN SCALE: 1/64" = 1.O" • VICINITY MAP NO SCALE REVIEWED FOR CODE COMPLIANCE APPROVED MAY 0 5 2011 K- City BUILDIN Ia VIRION HVAC PLAN SCALE: 1/4" = 1 =0" SEPARATE PERMIT REQUIRED FOR: 0 Mechanical Electrical )i4i Plumbing Gas Piping City of Tukwila Et.ell,OING DIVISION. REPLACE � WITH LIKE SEISMIC N SLEEPER EXISTING IN SAME WH UNIT ICH AR FAILED UNIT LOCATION. TO EXISTING E ROOFED IN. CU -1. 31' -i0" OOF ED E KING COUNTY PARCEL NO.: 883650 -0070 LEGAL DESCRIPTION: UPLANDS TUKWILA INDUSTRIAL PARK HVAC EQUIPMENT SCHEDULE TAG MFCR DESCRIPTION MODEL NO. NOMINAL TONS CAPAC /TY- BTUH HEATING COOLING SEER/EER CFM ELECTR /CAL VOLTS PHASE MCA MCOP SOUND dB(A) WEIGHT (LBS.) REMARKS FC -1 MITSUBISHI SPLIT SYSTEM A/C UNIT — INDOOR PCA— A24KA4 2 800 16.8/10.3 800 37 71 LOW AMBIENT CONTROL, COOLING ONLY CU -1 MITSUBISHI SPLIT SYSTEM A/C UNIT— OUTDOOR PUK— A24NHA4 » ,, » » » » ,► 115 10 18A 30A 48 163 REVISIONS No changes shall be made to the scope Of work without prior approve: l of Tukwila Building Division.. NOTE: Revisions will require a new plan submittI and may include additional plan review tees. 0 CV 6 x128 GLB 4x14 PURLIN 0 8' O.C. TYP. ROOF EDGE PARTIAL ROOF PLAN SCALE: 1/4" =1 =0" 10x10 WOOD COLUMNS TYP. FILE COPY Permit NO. AA 1 Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the. violation of any adopted code or ordinance. Receipt Of approved Field Copy and conditions is acknowledged: By. r-e 4.1 - Date:., S /'9h .. .. City Of Ithkw fa BUILDING DIVISION SCOPE OF WORK INSTALL (1) NEW MITSUBISHI COOLING ONLY SPOT SYSTEM TO REPLACING FAILING EXISTING UNIT. CODE NOTES: (PER W.S.E.C.) 1) INSULATE PIPING PER W.S.E.C. TABLE 14 -6 2) COOLING EQUIPMENT EXEMPT FROM AIR ECONOMIZER REQUIREMENTS W.S.E.C. SECTION 1433, EXCEPTION #9 WITH OPTION 9A 3) A 110V CONVENIENCE OUTLET SHALL BE WITHIN 25-0" OF OUTDOOR EQUIPMENT PER I.M.C. SECTION 306. 4) ROOF ACCESS TO EQUIPMENT TO COMPLY WITH I.M.C. SECTION 306. floGb RECEIVED rtiAY a4 Elf PERMIT CEEB , Dynamic Solutions for the Built Enviroment Q 0 o) z 0 u) /\CITY PLAN REVIEW CORRECTIONS 2 0 z 0 0 y DATE: 5/3/2011 DRAWN: KB ENGR: MS APPVD: JOB NUMBER: 3497 -11 M1 SHEET 1 OF 1 _ _ LC_ SERVER _ _ 1 . IM 1 II I NEW INDOOR UNIT TO REPLACE THE EXISTING IN SAME LOCATION. NEW COPPER REFRIGERANT LINES INSTALLED FROM CU -2 THRU EXISTING DOGHOUSE ON ROOF DOWN TO FC -2. c_r___, EXTERIOR WEST WALL F-P 11 11 _1L _ J yF 7 I I NEW CONDENSATE PIPING AND PUMP TO TERMINATE AT THE ROOF. 2 HVAC PLAN SCALE: 1/4" = 1 =0" SEPARATE PERMIT REQUIRED FOR: 0 Mechanical Electrical )i4i Plumbing Gas Piping City of Tukwila Et.ell,OING DIVISION. REPLACE � WITH LIKE SEISMIC N SLEEPER EXISTING IN SAME WH UNIT ICH AR FAILED UNIT LOCATION. TO EXISTING E ROOFED IN. CU -1. 31' -i0" OOF ED E KING COUNTY PARCEL NO.: 883650 -0070 LEGAL DESCRIPTION: UPLANDS TUKWILA INDUSTRIAL PARK HVAC EQUIPMENT SCHEDULE TAG MFCR DESCRIPTION MODEL NO. NOMINAL TONS CAPAC /TY- BTUH HEATING COOLING SEER/EER CFM ELECTR /CAL VOLTS PHASE MCA MCOP SOUND dB(A) WEIGHT (LBS.) REMARKS FC -1 MITSUBISHI SPLIT SYSTEM A/C UNIT — INDOOR PCA— A24KA4 2 800 16.8/10.3 800 37 71 LOW AMBIENT CONTROL, COOLING ONLY CU -1 MITSUBISHI SPLIT SYSTEM A/C UNIT— OUTDOOR PUK— A24NHA4 » ,, » » » » ,► 115 10 18A 30A 48 163 REVISIONS No changes shall be made to the scope Of work without prior approve: l of Tukwila Building Division.. NOTE: Revisions will require a new plan submittI and may include additional plan review tees. 0 CV 6 x128 GLB 4x14 PURLIN 0 8' O.C. TYP. ROOF EDGE PARTIAL ROOF PLAN SCALE: 1/4" =1 =0" 10x10 WOOD COLUMNS TYP. FILE COPY Permit NO. AA 1 Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the. violation of any adopted code or ordinance. Receipt Of approved Field Copy and conditions is acknowledged: By. r-e 4.1 - Date:., S /'9h .. .. City Of Ithkw fa BUILDING DIVISION SCOPE OF WORK INSTALL (1) NEW MITSUBISHI COOLING ONLY SPOT SYSTEM TO REPLACING FAILING EXISTING UNIT. CODE NOTES: (PER W.S.E.C.) 1) INSULATE PIPING PER W.S.E.C. TABLE 14 -6 2) COOLING EQUIPMENT EXEMPT FROM AIR ECONOMIZER REQUIREMENTS W.S.E.C. SECTION 1433, EXCEPTION #9 WITH OPTION 9A 3) A 110V CONVENIENCE OUTLET SHALL BE WITHIN 25-0" OF OUTDOOR EQUIPMENT PER I.M.C. SECTION 306. 4) ROOF ACCESS TO EQUIPMENT TO COMPLY WITH I.M.C. SECTION 306. floGb RECEIVED rtiAY a4 Elf PERMIT CEEB , Dynamic Solutions for the Built Enviroment Q 0 o) z 0 u) /\CITY PLAN REVIEW CORRECTIONS 2 0 z 0 0 y DATE: 5/3/2011 DRAWN: KB ENGR: MS APPVD: JOB NUMBER: 3497 -11 M1 SHEET 1 OF 1