HomeMy WebLinkAboutPermit M11-059 - BOEING #9-53BOEING #9 -53 9725 EAST MARGINAL wys Mi 1 -059 City oftukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov MECHANICAL PERMIT Parcel No.: 0003400018 Address: 9725 EAST MARGINAL WY S TUKW Project Name: BOEING #9 -53 Permit Number: M11 -059 Issue Date: 05/27/2011 Permit Expires On: 11/23/2011 Owner: Name: BOEING COMPANY THE Address: PROPERTY TAX DEPT , PO BOX 3707 M/C 20 -00 98124 Contact Person: Name: KOREY DUNKEL Address: 1221 2 AV N , KENT WA 98032 Email: KDUNKEL @HERMANSON.COM Contractor: Name: HERMANSON COMPANY LLP Address: 1221 2ND AV N , KENT, WA 98032 Contractor License No: HERMACLOO5BJ Phone: 206 575 -9700 Phone: 206 - 575 -9700 Expiration Date: 08/25/2012 DESCRIPTION OF WORK: DIFFUSER SHUFFLE AND DUCT ROUTE REVISIONS. Value of Mechanical: $36,250.00 Type of Fire Protection: SPRINKLERS /AFA Electrical Service Provided by: Permit Center Authorized Signature: Fees Collected: $636.81 International Mechanical Code Edition: 2009 Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this permit. , Signature: Print Name: Wiroffat. w Abb. Date: 5 I 1 This permit shall become null and void if t - work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -4/10 M11 -059 Printed: 05 -27 -2011 • • PERMIT CONDITIONS Permit No. M11 -059 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: All plumbing and gas piping work shall be inspected and approved under a separate permit issued Ploy the City of Tukwila Building Department (206- 431 - 3670). 6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of'Ikwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 8: ** *FIRE DEPARTMENT CONDITIONS * ** 9: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 10: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 11: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the powei source of the air- moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 12: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) 13: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) 14: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 15: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 16: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is, required for this project. 17: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 18: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 19: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 20: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: IMC -4/10 M11-059 Printed: 05 -27 -2011 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.cLtukwila.wa.us Mechanical Permit No. O Project No. (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: Tenant Name: 9725 East Marginal Way South King Co Assessor's Tax No.: 0003400018 Boeing Suite Number: Property Owners Name: Boeing New Tenant: Floor: ❑ Yes m ..No Mailing Address: Boeing DC Seattle WA City State Zip CONTACT PERSON - Who do we contact when your permit is ready to be issued Name: Korey Dunkel Day Telephone: (206) 575 -9700 Mailing Address: 1221 2nd Ave N Kent WA 98032 City E -Mail Address: kdunkel @hermanson.com Fax Number: State (206) 575 -9800 Zip MECHANICAL CONTRACTOR INFORMATION Company Name: Hermanson Co LLP Mailing Address: 1221 2nd Ave N Kent WA 98032 City Contact Person: Korey Dunkel Day Telephone: E -Mail Address: kdunkel @hermanson.com Fax Number: Expiration Date: Contractor Registration Number: 09 -459 State (206) 575 -9700 (206) 575 -9800 1 2/31 /2Dka 2i tt Zip ARCHITECT OF RECORD All plans must be wet stamped by Architect of Record Company Name: Mailing Address: City Day Telephone: E -Mail Address: Fax Number: Contact Person: State Zip ENGINEER OF RECORD - All plans must be et stamped by Engineer of Record Company Name: 1i:1'e— t 't Mailing Address: q 7 Z frIckrit tics 1 in>L. 5 Contact Person: X t.. City Day Telephone: E -Mail Address: Fax Number: State Zip 1-1:\Applications\Forms- Applications On Line \2009 Applications \1 -2009 - Mechanical Permit Application.doc Revised: 1 -2009 bh Page 1 of 2 Valuation of Project (contractor's bid price): $ 36,250 Scope of Work (please provide detailed information): Diffuser shuffle and duct route revisions Use: Residential: New Commercial: New Fuel Type: Electric ❑ Replacement Replacement Gas ❑ Other: Indicate type of mechanical work being installed and the quantity below: Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace <100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace >100K BTU Evaporator Cooler Diffuser 13 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall /Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or addition to Heat/Refrig /Cooling System Incinerator — Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM Incinerator — Comm/Ind PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature:_ (3 Print Name: " ----Ta- . 6 tv- Mailing Address: 1221 2nd Ave N Date: 5-76/ z"7 (( Day Telephone: (206) 575 -9700 Kent WA 98032 City State Zip Date Application Accepted: 5(0 6 (// Date Application Expires: Staff Initials: H:\ Applications \Forms - Applications On Line \2009 Applications \I -2009 - Mechanical Permit Application.doc Revised: 1 -2009 bh Page 2 of 2 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: / /www.TukwilaWA.eov RECEIPT Parcel No.: 0003400018 Permit Number: M11 -059 Address: 9725 EAST MARGINAL WY S TUKW Status: APPROVED Suite No: Applied Date: 05/06/2011 Applicant: BOEING #9 -53 Issue Date: Receipt No.: R11 -01085 Payment Amount: $509.45 Initials: WER Payment Date: 05/27/2011 10:55 AM User ID: 1655 Balance: $0.00 Payee: JESICA ROGERS TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 217245 ACCOUNT ITEM LIST: Description 509.45 Account Code Current Pmts MECHANICAL - NONRES 000.322.102.00.00 509.45 Total: $509.45 doc: Receipt -06 Printed: 05 -27 -2011 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: ht4,://www.ci.tukwi la. wa. us RECEIPT Parcel No.: 0003400018 Permit Number: M11 -059 Address: 9725 EAST MARGINAL WY S TUKW Status: PENDING Suite No: Applied Date: 05/06/2011 Applicant: BOEING Issue Date: Receipt No.: R11 -00916 Initials: User ID: LAW 1632 Payment Amount: $127.36 Payment Date: 05/06/2011 02:43 PM Balance: $509.45 Payee: HERMANSON TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 616014 ACCOUNT ITEM LIST: Description 127.36 Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 127.36 Total: $127.36 doc: Receiot -06 Printed: 05 -06 -2011 2,-/' INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Projec� isoAo q —5j Type Ins : r-1Af4-L Ad e si:^ ; f pate Called: Special Instructions: Date Wanted: .-- r —�' p.m. Requester: Phone No: Approved per applicable codes. E1 Corrections required prior to approval. / COMMENTS: Ate p( Inspe tor: exkita.Q tit ,/,._,j I E ION FEE REQUIRED. rior to Date: / '7 — ri RE NSP CT next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. 'Ci; :�-.. zx }:T ;;nor -• C`: +rte -w�l ��:r4"�.. - - - - '..�- a. ;y- �'...rk:- .x;.�•.'4 - r.' .7.7. a'• INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 R (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Pro& N —.Si Type of 'on: J r tjL.` �� _l-a a Address: d� nn]��. f DateJC�alled: Special Instructions: Date Wanted: 19— 8 a.mrry . Requester: Phone No: Approved per applicable codes. Il Corrections required prior to approval. COMMENTS: l akit) 111 ❑ REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Inspe tor: Dater , [ — 1 • 0 Hermanson Hermanson Company LLP 1221 2nd Avenue North Kent, WA 98032 David Larson Tukwila Building Department 6300 Southcenter Blvd Tukwila, WA 98188 RE: Correction Letter #1 Mechanical Permit Number M11 -059 Boeing 9 -53 — 9725 East Marginal Way Tel 206 - 575 -9700 fax 206 - 575 -9800 • 1. Construction note # 3 refers to a CAC Station. What is a CA Station? A CA Station is a Control Air Station. The drawings have been noted. 2. Page 2M112 has no clouded areas. Please remove this page if it is not needed. Page 2M112 Has been Removed. 3. Sheets 2M261 & M21262 are sprinkler plans and any sprinkler work will be under a separate fire department permit issued directly from the Tukwila Fire Department. Please remove these pages from the application. These pages have been removed. Thank you, Jesica Rogers Specialty Services Group Hermanson Company, LLP 1221 2ND Ave North Kent, WA 98032 253 - 796 -5814 Mechanical Construction, Engineering and Service www.hermanson.com May 17, 2011 • City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director Korey Dunkel Hermanson Co 1221 2nd Av N Kent, WA 98032 RE: Correction Letter #1 Mechanical Permit Application Number M11 -059 Boeing #9 -53 — 9725 East Marginal Wy S Dear Mr. Dunkel, This letter is to inform you of corrections that must be addressed before your mechanical permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. The Fire Department has no corrections at this time. Building Department: Dave Larson at 206 431 -3678 if you have questions regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that two (2) sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3670. Sincerely, 9)-44iLP Bill Rambo Permit Technician encl File: M11 -059 W:\Permit Center \Correction Letters\2011\M11 -059 Correction Letter #1.doc 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 Tukwila Building Division Dave Larson, Senior Plan Examiner Building Division Review Memo Date: May 13, 2011 Project Name: Boeing #9 -53 Permit #: M11 -059 Plan Review: Dave Larson, Senior Plans Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and /or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be theisame size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. Construction note #3 refers to CA station. What is a CA station? 2. Page 2M112 has no clouded areas. Is there any scope of work in this area. Please remove this page if it is not needed. 3. Sheets 2M261 and 2M262 are sprinkler plans and any sprinkler work will be under a separate Fire Dept. permit issued directly by the Tukwila Fire Department. Please remove these pages from this application. Should there be questions concerning the above requirements, contact the Building Division at 206 -431- 3670. No further comments at this time. SRMffCOORDCOPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M11 -059 DATE: 05/23/11 PROJECT NAME: BOEING #9 -53 SITE ADDRESS: 9725 EAST MARGINAL WY S Original Plan Submittal X Response to Correction Letter # 1 Response to Incomplete Letter # Revision # after Permit Issued DEPARTME TS: pry B it ing Division Public Works II Fire Prevention Structural Planning Division ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete 174 Incomplete DUE DATE: 05/24/11 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route REVIEWER'S INITIALS: Structural Review Required No further Review Required DATE: APPROVALS OR CORRECTIONS: DUE DATE: 06/21/11 Approved Approved with Conditions Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 ERMT COORD COPY • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M11 -059 DATE: 05/06/11 PROJECT NAME: BOEING #9-53 SITE ADDRESS: 9725 EAST MARGINAL WY S X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # after Permit Issued DEPAR MENT : e uilding Division Public Works n ,/W\ /wC S ®'tI ire Prevention Structural ❑ Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete n DUE DATE: 05/10/11 Not Applicable u Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route Structural Review Required n REVIEWER'S INITIALS: No further Review Required ❑ DATE: APPROVALS OR CORRECTIONS: Approved Notation: REVIEWER'S INITIALS: Approved with Conditions DUE DATE: 06/07/11 Not Approved (attach comments) g DATE: Permit Center Use Only CORRECTION LETTER MAILED: 'N11". 11 Departments issued corrections: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: JIVI /IU Documents/routing slip.doc 2 -28 -02 • City of Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: Plan Check/Permit Number: M11-059 ❑ Response to Incomplete Letter # Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Boeing #9-53 Project Address: 9725 Est Marginal wy S X5:1°14 Contact Person: Phone Number: Summary of Revision: ern'' OF ru kwu MAY 232011 PERMIT CENTER t Sheet Number(s): • 11t 2 %-A1.1 t N` \ Z � 1 z ` 1 " f5b1 "Cloud" or highlight all areas of revision including date of revision' -A, v1) ,\ J u a. Received at the City of Tukwila Permit Center by: Entered in Permits Plus on \applications \forms- applications on Tine \revision submittal Created: 8 -13 -2004 Revised: Contractors or Tradespeople Peer Friendly Page • General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name HERMANSON COMPANY LLP UBI No. 602004844 Phone 2065759700 Status Active Address 1221 2Nd Ave N License No. HERMACLOO5BJ Suite /Apt. License Type Construction Contractor City Kent Effective Date 1/11/2000 State WA Expiration Date 8/25/2012 Zip 980322945 Suspend Date County King Specialty 1 General Business Type Limited Liability Partnership Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status HERMAC'016RN HERMANSON CORPORATION Construction Contractor General Unused 1/11/2000 8/21 /2002 Archived HERMAC'217NT HERMANSON CORPORATION Construction Contractor Air Heat,Ventilation,Evaporat Metal Fabrication 8/30/1979 8/21/2000 Archived Business Owner Information Name Role Effective Date Expiration Date NICOLAISEN, KNUT H Partner /Member 08/05/2010 Bond Amount BROCK, DANIEL L Partner /Member 08/05/2010 929381801 FOX, DEAN M Partner /Member 08/05/2010 HENGEL, STEPHEN A Partner /Member 08/05/2010 TRAVELERS CAS Et SURETY CO DYCKMAN, KENNETH A Partner /Member 08/05/2010 01/01/2006 ROBINETT, PAUL J Partner /Member 08/05/2010 HERMANSON, RICHARD L Partner /Member 01/01/1980 ALMON, KEVIN Partner /Member 01/01/1980 08/05/2010 MACDONALD, JAMES Partner /Member 01/01/1980 08/05/2010 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 4 WESTERN SURETY CO 929381801 01/01/2006 Until Cancelled $12,000.00 12/01 /2005 3 TRAVELERS CAS Et SURETY CO 081S103514123BCM 07/22/2001 Until Cancelled 01/01/2006 $12,000.0008/21 /2001 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 9 American GL0370326107 08/21/2010 08/21/2011 $1,000,000.00 08/18/2010 Zurich Ins Co ZURICH 8 AMERICAN INS GL0370326106 08/21/2008 08/21/2010 $1,000,000.00 08/24/2009 CO 7 AMERICAN GL03703261 08/21/2004 08/21/2008 $1,000,000.00 08/20/2007 ZURICH INS CO 04 6 AMERICAN ZURICH INS CO GL03703261 03 08/21/2004 08/21/2007 $1,000,000.00 08/18/2006 https: // fortress .wa.gov /lni/bbip /Print.aspx 05/27/2011 AIR DIFFUSER /REGISTER /GRILLE SCHEDULE MARK NUMBER TYPE MATERIAL FINISH FACE SIZE INCHES INLET/ NECK INCHES SIZE MAXIMUM NOISE COEFFICIENT MAXIMUM TP INCH WG MAXIMUM SET CFM REMARKS CD -1 SQUARE CEILING DIFFUSER STEEL WHITE 12x12 60 20 .060 140 CARNES SJTA CD -2 SQUARE CEILING DIFFUSER STEEL WHITE 24x24 80 21 .110 275 CARNES SJTA CD -3 SQUARE CEILING DIFFUSER STEEL WHITE 24x24 100 24 .130 425 CARNES SJTA CD -4 SQUARE CEILING DIFFUSER STEEL WHITE 24x24 - 120 23 - .127 550 CARNES SJTA CD -5 SQUARE CEILING DIFFUSER STEEL WHITE 24x24 140 29 .240 950 CARNES SJTA CD -6 ROUND CEILING DIFFUSER STEEL WHITE 240 80 26 .08 260 CARNES SSAA CD -7 ROUND CEILING DIFFUSER STEEL WHITE 300 100 26 .07 315 CARNES SSAA CD -8 ROUND CEILING DIFFUSER STEEL WHITE 400 1 140 24 .03 750 CARNES SSAA RG -1 PERFORATED CEILING RETURN GRILLE STEEL WHITE 24x24 80* 21 .04 550 CARNES SPRB222 RG -2 PERFORATED CEILING RETURN GRILLE STEEL WHITE 24x24. 120 20 .03 800 CARNES SPRB222 RG -3 PERFORATED CEILING RETURN GRILLE STEEL WHITE 12x24 - -- 20 .02 300 CARNES SPRB222 EG -1 CEILING EXHAUST GRILLE STEEL WHITE VARIES - -- 44 .07 VARIES CARNES RSLAM * INLET DUCT SIZE TO PLENUM PLUMBING FIXTURE CONNECTION SCHEDULE MARK NUMBER DESCRIPTION CONNECTION (INCHES) REMARKS SAN VENT HW CW P -1 ' WATER CLOSET 4 2 - 1 WALL -HUNG FLUSH VALVE P-1A WATER CLOSET 4 2 - 1 WALL -HUNG FLUSH VALVE (HANDICAP) P -2 URINAL 2 1 1/2 - 3/4 WALL -HUNG FLUSH VALVE P -3 LAVATORY 1 1/4 1 1/4 1/2 1/2 OVAL COUNTER RECESSED P -3A LAVATORY 1 1/4 1 1/4 1/2 1/2 OVAL COUNTER RECESSED (HANDICAP) P -4 SERVICE SINK 3 2 1/2 1/2 FLOOR TYPE P -5 ELECTRIC WATER COOLER 1 1 /4 1 1 /4 - 1 /2 WALL MOUNTED (HANDICAP) P -6 SINK 2 1 1/2 1/2 1/2 - P-7 EMERG EYE WASH 1 1/4 1 1/4 - 1/2 - FD-1 FLOOR DRAIN 2 2 - - - FD -2 FLOOR DRAIN 2 - - - W/ FUNNEL FS -1 FLOOR SINK 6 3 - - FLOOR SINK SEPARATE' PERMIT IT REQUIRED FOR: ❑ Mechanical Electrical Plumbing Gas Piping City of Tukwila BUILDING DIVISION EXHAUST FAN (EF) SCHEDULE MARK NUMBER LOCATION AREA SERVED (ROOM NO.) EXHAUST FAN SECTION REMARKS FAN SIZE MFG. SIZE NO. ARRNGMT. NUMBER CFM (* MAX) TOTAL STATIC PRESS. INCHES WG MAX. OUTLET VELOCITY FPM APPROX. RPM DRIVE SIDE INLET GUIDE VANES MOTOR HP EFRCC10 ROOF TOILET ROOM(S) 18" CRE -18F - 2650 3/4 1400 510 - - 1 GREENHECK LB -18 -10 W/ BIRD SCREEN AND B.D. EFRCC3 ROOF STORAGE 9" CRE -9F - 875 3/4 1550 1029 - - 1/2 GREENHECK LB -10 -5 W/ BIRD SCREEN AND B.D. EF2CC2 FAN ROOM FIRST FLOOR 44" 44 1 20,000* 1.5 1620 771 - - 10 TRANE MODEL Q, AXIAL FLOW EF2BB2 FAN ROOM SECOND FLOOR 40" 40 1 16,200* 1.5 1480 852 - - 7.5 TRANE MODEL Q, AXIAL FLOW DOMESTIC HOT WATER HEATER (HWH) SCHEDULE MARK NUMBER KW INPUT TANK STORAGE GALLONS CODE STAMP RECOVERY ELECTRICAL REMARKS GPM d VOLTS /PH /HZ HW -1 9 65 ASME 37 100 480/3/60 A.O.SMITH MOD. DSE -65 HW -2 1.5 6 100 6 100 120/1/60 A.O.SMITH MOD. DEL -6 if- IS I. 1 • 10 4 0 '.8 I - 10 W -3 200 -600 0.30 35 8 600 6 VARIABLE AIR VOLUME TERMINAL UNIT (VAV) SCHEDULE MARK NUMBER AIR QUANT. RANGE CFM PRIMARY AIR PRESSURE DROP AT MAXIMUM INCH WG MAX. NC LEVEL © 1.5" WG INLET COOLING HEATING DISCHARGE DUCT REMARKS SIZE (INCH) CFM INLET SIZE CFM SIZE SOUND LINE LENGTH FEET VV -1 0 -150 0.30 35 4 150 4 100 8x6 4 TITUS EDV -3100 - if- IS I. 1 • 10 4 0 '.8 I - 10 W -3 200 -600 0.30 35 8 600 6 300 12x10 6 TITUS EDV -3100 t■-4 1: -,1: :. 0 _ 1 •:I . 4 , 4 1- IY- if VV -5 400 -1500 0.30 35 12 1400 10 750 20x12 10 TITUS EDV -3100 REVISIONS Na changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. 90% DESIGN REVIEW SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE A RECORD DRAWING MJC KMR /RB 8.30.91 B THE DALLAS PROJECT J #12010 -10/11 FSi 05.02.11 Q�BOE /NG' o-- ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN L DEWALT CHECKED W. HENCKEL ENCINEER D.MEYER DATE SUBTITLE SCHEDULES MEp �R ADE C ADDROVED MAY 2 5 0 �L City of u ila BUILDING icim FILEnnCOPY Permit No. l �+ � 1 Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approve • Fi : Id Copy b conditions is acknowledged: By Date:. J '� RECEIV6,p_ CYf`/ OFTUitvmLA MAY 2 3 2011 PERMIT CENTER City Of Tukwila BUILDING DIVISION CORRECTION M1LO561 CURRENT REVISION J #12010 -10/11 SYMBOL B DATE 05.02.11 CHECKED W. HENCKEL APPROVED K. RAMSEY TITLE BUILDING 9 -53 SHEET M3 JOB NO. COMP NO. 13, COMPUTER ROOM COOLING UNIT (CRU) SCHEDULE MARK NUMBER LOCATION (ROOM NUMBER) TYPE NOMINAL CAPACITY TONS FAN COIL COOLING CAPACITY CHILLED WATER HUMIDIFIER ELECTRIC REHEAT COIL # /HR AIR FILTER REMARKS * HP* CAPACITY ESP IN WG CAPACITY MBH RM TEMP F FLOW GPM EWT °F LWT °F MAX PD © MAX FLOW FT H2O CAP # /HR KW* TYPE & DEPTH EFFICIENCY ER ASHRAE 52 -76 MAX FINAL SP WG - SENSIBLE TOTAL DB WB CR1BB6 NCO LAB SELF CONTAINED 30 15 16,500 0.5 392 517 75 62.5 110 45 55 46.4 22.1 9.6 127,900 10 -8X24 4" 30 0.3 LIEBERT CW114UCVA2, UP -FLOW, 2WAY VALVE CR2BB11 HI LAB SELF CONTAINED 12 2.0 5250 0.3 94.5 109.8 75 62.5 22 45 55 9.4 11.0 4.8 - -- 4 -18 x24 30 0.6 LIEBERT, FLOOR MOUNTED,DOWN -FLOW CR2CC8 K4 LAB SELF CONTAINED 25 5.0 9300 0.3 188.8 225.1 75 62.5 45 45 55 7.5 17.4 6.4 - -- 6 -18x24 4„ 30 0.6 LIEBERT, FLOOR MOUNTED,DOWN -FLOW CR2CC7 K3 LAB SELF CONTAINED 25 5.0 , 9300 0.3 188.8 225.1 75 . 62.5 45 45 55 7.5 17.4 6.4 - -- 6 -18x24 30 0.6 LIEBERT, FLOOR MOUNTED,DOWN -FLOW C FARR 12" RLGAFIOW ' ' - 0 TRANE/21B • 9 ' ! 8 4.0 9,500 15 1750 - -- - -- - -- 4 • 4 - -- 6- 18x24 . • . : . 11? , _ ∎ T • I t i , - • XXX 21C7 SELF CONTAINED 5 1 -1/2 2800 0.3 56.5 69.5 75 62.5 14.7 45 55 16.6 N/A N/A - -- 28.5x29.5 30 0.3 LIEBERT, CHALLENGER 3000, DOWN - FLOW ** NOTES * 460V/30/60HZ ** EQUIPMENT PROVIDED BY BOEING, INSTALLED BY CONTRACTOR FAN COIL UNIT (FC) SCHEDULE MARK NUMBER LOCATION SERVED TYPE TOTAL STAT.PR. IN. WG CFM MOTOR COOLING DATA HEATING DATA FILTER DATA MANU./MODEL / REMARKS HP* RPM MBH TOTAL MAX FACE VELOCITY ° EAT °F ° LAT F EWT F LWT F GPM MAX PD FT WATER MBH TOTAL EAT F LAT F EWT F LWT 'F GPM MAX PD FT WATER PREFILTER FINAL FILTER FACE VEL FPM DB WB DB WB FC2CC1 FIRST FLOOR COOLING 5.0 23,500 30 1750 598 580 77.0 62.7 56.7 54.2 45 55 120 10 --- - -- - -- - -- - -- - -- - -- FARR 30/30 RIGFARAFLR OW 12" 500 TRANE / 41H 30" AIR FOIL WHEEL FC2BB1 SECOND FLOOR COOLING 5.0 19,000 30 1750 610 540 77.1 61.5 52.7 50.7 45 55 122 10 - -- - -- - -- - -- - -- - -- - -- FARR 30/30 12 " GAF RJ FARR L9W 500 TRANE /35K 24.5" AIR FOIL WHEEL FC2CC2 FIRST FLOOR HEATING ! 4.0 11,750 15 1750 - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- 366.5 75 101 170 140 25 1.0 FARR 30/30 / FARR 12" RLGAFIOW 500 TRANE/21B 22" FC WHEEL FC2BB2 SECOND FLOOR HEATING 4.0 9,500 15 1750 - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- 397.0 75 109 170 140 27 1.0 FARR 30/30 FARR 12" R LGAFLOW 500 TRANE /21B 22" FC WHEEL * 460V/30/60HZ CHILLE "- _ _ ULE MARK NUMBER TYPE CAPACITY TONS MAX* KW EVAPORATOR CONDENSER REMARKS FLOW GPM EWT `F LWT `F • PASS MAX PD ' ' FT H2O FOULING A. _ A REFRIG FLOW GPM EWT `F NO ' , MAX PD FT H20 11 LING FACTOR REMARKS CH1B-2 SCREW 280 208 750 53 44 3 24.43 . • • • _ BRONZE 75 8 DIRECT 20.52 .00025 TRANE RTHA 300, LONG SHELL OR APPROVED • -22 900 i CONDENSER WATER 85° 900 50 6 5 CAST IRON BRONZE 77 9 DIRECT 20 1750 END SUCTION PACO, 5095 -7 BRG FRAME 62 COOLING TOWER (CT) SCHEDULE MARK NUMBER GPM EWT 'F LWT `F AMBIENT AIR FANS FAN MOTORS SUMP HEATER REMARKS °F DB °F WB NO. TYPE CFM NO. HP* NO. KW CTRB -2 900 94 85 85 68 3 CENTRIF. 49770 1 1 ©7.5 ©10 1 5 BALTIMORE AIR COIL VXTN215 OR APPROVED (SPECIAL ORDER) BRONZE 75 8 DIRECT 15 1750 END SUCTION PACO, 4095 -7 BRG FRAME 62 PU1B -1B CONDENSER WATER 85° 900 50 6 5 CAST IRON BRONZE 77 9 DIRECT 20 1750 END SUCTION PACO, 5095 -7 BRG FRAME 62 * 460V/30/60HZ PUMP (PMP) SCHEDULE MARK NUMBER SERVICE FLUID TEMP °F CAPACITY SIZE (IN) CONSTRUCTION PERFORMANCE MOTOR PUMP TYPE MANUFACTURER AND MODEL REMARK GPM TDH SUCT DISCH BODY FITTINGS E% NPFTR DRIVE TYPE HP* RPM PU1 B -1 A CHW WATER 53° 750 40 a 5 4 CAST IRON BRONZE 75 8 DIRECT 15 1750 END SUCTION PACO, 4095 -7 BRG FRAME 62 PU1B -1B CONDENSER WATER 85° 900 50 6 5 CAST IRON BRONZE 77 9 DIRECT 20 1750 END SUCTION PACO, 5095 -7 BRG FRAME 62 * 460V/30/60HZ SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE A R1 LAB REVISION MJC KMR /LL 9.7.90 B RECORD DRAWING MJC KMR /RB 8.30.91 C THE DALLAS PROJECT J #12010 -10/11 FSi 05.02.11 Q� BOE /NG' ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN L. DEWALT CHECKED W. HENCKEL ENGINEER D.MEYER CHECKED W. HENCKEL DATE SUBTITLE REVIEWED FOR CODE COMPLIANCE APPROVED MAY 25 2011 City of Tukwila BUILDINGnIVICInM 90% DESIGN REVIEW SCHEDULES M CITY OF TUKWILA MAY 2 3 2011 PERMIT CENTER CURRENT REVISION J #12010 -10/11 SYMBOL DATE 05.02.11 APPROVED K. RAMSEY TITLE BUILDING 9 -53 SHEET M4 JOB NO. COMP NO. 14x10 22x18 1310 65 20x12 20x12 14x10 86x50 .M Iu ����•� ■I■ RAR -1 20x16 22x18 420 -RAR -1 420 RAR -1 800 15x8 VD 22x15 18x12 960 18x12 50 86x50 20x14 100 CFM VD 20x18 (H) 480CFM 12X10 SUPPLY AIR GRILLE, TITUS 300RL CAP LOS RAR - 1390 RAR -1 715 CFM Z3C ! %H 14'10 MANBARS & ACCESS DOOR 10"O 910CFM, 18X18 RETURN AIR GRILLE, TITUS 350RL W/ OBD & MOTORIZED FIRE DAMPERS RAR -1 420 VD All rs -rii— .� � 4■WAI n 61 10 17X11 mrimmool ■■ IN 62x37 (H) 28x18 22x18 18x12 19x12 990 2M11 M501 24x18 72x42 430CFM 12X10 SUPPLY AIR GRILLE, TITUS 300RL LOI KED CLOSED 1980 56 NUM 64x32 12x14 VD 20x16 22x14 1670 58 22x 14 14x10 560 20x14 14x10 RAR -1 800 18x12 16x10 RAR -1 610 CFM VD BOTTOM OF SUP'LY & RETURN DIFFUSERS IN THIS AREA TO BE 12' -0" AFF 20x14 Z3D 14x12 20x18 RA 77 22x16 MM MW RAR -1 310 CF -18X1 900 99 15 15 72x42 AR -1 00 CFM 15x10 500 8 610 �' 10 18x12 RAR -1 610 CF 16x10 RAR- 1 1390 CFM BOTTOM AT 25' -0" AFF 42X37 74x42 RAR -1, 440 CFM RAR 1 1390 CFM 1120 14x11 55 11x11 17X14 14x10 10x14 22x16 (H) 24x20 19x12 16x14 14X1 VD 19x12 32x26 RAR -1 560 CFM VD (H) 14x11 22x16 440 8 ■ ■ I RAR -1, 1390 CFM 560 ■IMI F [Ll ► 32x 12 .. 1 1 I .I,._c.�..�....i.:rai.:�r^ �!� RAR -1 5 in ���� 11 Id 1r► -I �►' - - - Iii■ mm x 14 ■ 16x 10 III1iL!I • �� 10x 10 1■ Ia ll.1�■IMM111 ■7�, ,� V[ 6x 16 '- 780 12x9 RAR -1 310 CFM 20x14 16x10 1 560 CFM 32x26 �� ■�I AVM 16x VALWARIIIIM%/ff 32x18 // E��c 32x22 r -14x10 20x16 1500 1500 46 47 24x 18 ��t� ■ 5600 4x11 R 300 ` 10 1'iii �� .. 8 "I- 860 iiII MIEINKI 111E111, I -�•� ;.0 ,4 ..► 300 C �`- , �� '�i 0�� �1�11i� nnn 26x14 840 10 14x14 DO CONNECT C UNIT MODEL CSF 2360CFM © .75 "SP VD 840 10 26x16 DN LEGEI\ D 18x16 RAG -1, 1:80 CFM, MOUNT 10FT. AFF 20TON EDPAC 92 "X33" BOEING 07502594 24x18 16x12 RAR -1 1125 CFM 62x32 16x12 '� 2 6x32 800 0 VD VD 18x14 14 VD igi 0 1150 r��, VD ,I III ;/�_ 1 45 24x14 iii I 18 14,�'I1�■ 11, 660 2 7 Ib111ir—''i 4x 14 al %Ii���l•tIIII @mai ♦ II I1 trIlaSE !.10 H r •AR - ►0x1. 1�1Mr ig, NI (H) 0 CF 1 non i 1 31I Ira ■ msmi ° ■ ii �►it • I -2x16 1 400 10 1050 43 14x12 14x10 24x22 f. 20x16 8 32x26 24x20 12x9 22x16 30 RAR -1 1150 CFM BOTTOM AT 575 14 VD 16x10 14x13 22x13 16x12 DOWN RETURN AIR, 186' BOX FOR (3) FILT INSTALLED ABOVE 1 310 CFM 22x16 24x22 32x 32x26 SECO\D FLOOR HVAC PLA\ SCALE: 1/8' =1' -0" SYM N R S REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE INSTALL RETURN AIR DIFFUSER D.M.V. R.W.S. 1.7.00 U E5118 —EPME DESIGN F -22 TRAINING LAB 9575682 M.WONG RWS 10.06.09 INSTALL MOTOR DRIVES J #775361 -04 S.L.B. E.J.C. 3.16.98 V THE DALLAS PROJECT J #12010 -10/11 FSi 05.02.11 INSTALL DIFFUSER J #700009 —L0 D.M.V. R.W.S. 1.7.00 CONVERSION FROM MYLAR TO CAD CCSI 12.10.00 QLBOE /A/G' ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN Y.L CHAN CHECKED D.P.N. ENGINEER DATE 9.20.85 10.10.85 SUBTITLE REVIEWED OF R ,ODE COMPLIANCE. ha DPROVED a MAY 2 5 2011 City of Tukwila BUILDING DIVISIfnl M L 90% DESIGN REVIEW SECOND FLOOR HVAC PLAN INDICATES MANBARS INSTALLED IN DUCT INDICATEDS LOCATION OF CAPACITANCE GRID AND LOCKABLE ACCESS WITH INSET VIEWING PANEL ACCESS FOR DUCT CLEANING GENERAL OTES 1 1 > LOCATION OF DUCT MOUNTED WHITE NOISE GENERATOR. CCNSTRUCTION \ OTES 4. RELOCATE EXISTING DIFFUSER. SEE DETAIL X/M638 FOR DUCT CONNECTION. RELOCATE EXISTING DUAL -DUCT TERMINAL UNIT. PROVIDE VIEWPORT AT (E) MAN -BARS AT WALL PENETRATION. SEE 2/M504 CONTRACTOR SHALL PROVIDE TAB SERVICES, AND SHALL VERIFY AND ADJUST AIRFLOW AT ALL DIFFUSERS IN PROJECT AREA. PROVIDE METAL NOSING ON EXPOSED DUCT LINER EDGES. VIBRATIONALLY ISOLATE DUCT FROM WALL SEE 1/M504. COVER AND SEAL DUCT PENETRATION LEFT BY DUCT DEMO. DO NOT SHORTCUT DUCT. EXTRA ELBOWS AND DUCT INDICATED ARE REQUIRED TO MEET SOUND CRITERIA. ADJUST GRILLE LOCATIONS AS REQUIRED FOR NEW CEILING GRID LOCATION. PROVIDE FLEX DUCT FOR FINAL CONNECTION TO THE DIFFUSER. SEE DETAIL X /M5XX. REFERENCE DRAWINGS RECEIVO! CITY OF TUK MLA MAY :2 3 2011 PERMIT CENTER 2M 3 2M14 2M10 —© 2M12 r KEY PLAN SCALE: NONE CURRENT REVISION J #12010 -10/11 SYMBOL DATE 05.02.11 CHECKED APPROVED TITLE BUILDING 9 -53 SHEET 2M11 JOB NO. COMP NO. A.6 RAR -1 960 CFM Be5 C.5 D./ L.25 —.4 -.5 12 1 1460 37 26x12 w C1 It■! 640 38 62x 62x26 22x16 730 RAR -1 730 CFM 320 8 14x8 CF RAR - 640 CF 16x1 (H) P741 20x18 46x32 x 10x8 400 TY -8 1860 1860 30x20 42 8) 1 12x9 RAR -1 310 CFM 14x10 38x26 10x8 RAR -1 400 JP 26x16 320 8 BOTTOM AT 30' -0" AFF 1860 15 30x20 OPEN TO BELOW 8"0 INL TITU PESV W/ TITUS 24X18 PACE A/C UNIT 12" 2360 CFM @ .50 SP MODEL SCF 114 -B MI 14' -0" A.F.F. ONE =M� ,30x20 A. F. F. 14X12 m s Warm 22x16 32x20 900 35 20x14 RAR -1, 1390 14' -0" A.F.F. ovamEnniorffibm ■ 1111=011 12 "0 590 CFM TITUS XC -310 (TYP. OF 4) D 14x14 28x15 950 12 22x16 RAR 411I'm Ira 310 CFM 20x14 j 14xl1 �►�__.�_ 480 �1` •11 ■tea: 8 36 i-I1i �'�I'll�►- PACE A/C UNIT CFM SCF 114 B4M .59 BHP 32x14 23x14 840 12 14x14 RETURN AIR, 1860 CFM W/ FILTER BOX FOR (3) COALESING FILTER RACKS. MANUAL DAMPER ABOVE FILTER RAN.SITION_ 16x12 18x12 10.3 P.O.C. 12 "0 550 CFM C -310 TYP. OF 2) 26x14 2M12 1M504 14x14 950 CFM 18x12' AR -1 50 CFM 30' -0" DOME SIMULATOR SEE DWG 1M512 �&Tti 26x14 14x14 16 "0 ELBOW DN TO A/C UNIT 14 "0 840 CFM TITUS XC -310 (TYP. OF 2) 950 12 BOTTOM OF SUP LY & RETURN DIFFUSE "S IN THIS AREA TO BE 12' -0" AFF BOTTOM AT 25' -0" AFF 840 12 (H) 1100 12 17x14 REVIEWED F R ODE COMPLIANCE . APPROVED MAY 2 5 2011 City of Tukwila UILDINGnIVIsirw 26 1/2 x 16 1/2 DN 18x16 RAG -1, 1680 CFM MOUNT 10 FT AFF MANBAR ASSEMBLY SHALL BE FURNISHED AT EVERY DUCT PENETRATION OVER 90 SQ. IN. THROUGH WALLS SURROUNDING SECURE AREAS. (INDICATED BY SHADING) SEE DETAIL 2M12 1M517 FLOOR PLA\ SCALE: 1 /8 "= 1' -0" 18x16 RAG -1, 1680 CFM MOUNT 10 FT AFF SYM H J K REVISION BY APPROVED DATE SYM REVISION BY APPROVED INSTALL MOTOR DRIVE J #775361 -04 S.L.B. E.J.C. 3.16.98 M DOME REMOVAL J #150655 -00 M.WONG RWS NEW RM @ B9 -8 RA GRILLS J #792418 R.A.D. R.W.J. 7.8.99 N RELOCATE BATTERY LAB 6132 RWS RWS CONVERSION FROM MYLAR TO CAD CCSI 12.10.00 0 THE DALLAS PROJECT J #12010 -10/11 FSi DATE 06.13.06 12.07.09 05.02.11 INSTALL DAMPERS AND BALANCE SYSTEM 545931 -00 RWS RWS 03.26.04 g)LAraPEzisw ® ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN Y.L. CHAN CHECKED D.P.N. ENGINEER DATE 9.20.85 10.10.85 SUBTITLE M 1 90% DESIGN REVIEW HVAC - SECOND FLOOR PLAN INDICATES MANBARS IN DUCT J° INDICATEDS LOCATION OF / CAPACITANCE GRID AND � LOCKABLE ACCESS WITH f INSET VIEWING PANEL ACCESS FOR DUCT CLEANING GENERAL \OTES 1. ALL DUCT SIZES SHOWN ARE INTERNAL CLEAR DIMENSIONS WITH ONE INCH SOUND LINING IN THE INSIDE OF ALL SUPPLY, RETURN AND EXHAUST DUCTWORK. 2. FOR EXACT LOCATIONS OF SUPPLY AND RETURN DIFFUSERS SEE ARCH. REFLECTED CEILING PLANS. 3. MOTORIZED DAMPERS FOR HALON FIRE SUPPRESSION SYSTEM TO BE LOCKED BACK TO RELEVANT ZONE HALON CONTROL PANEL BY CONTROL CONTRACTOR 1 1 > LOCATION OF DUCT MOUNTED WHITE NOISE GENERATOR. CONSTRUCTION NOTES RELOCATE EXISTING DIFFUSER. SEE DETAIL X/M638 FOR DUCT CONNECTION. PROVIDE MAN -BARS, AND VIEWPORT AT WALL PENETRATION. SEE 2 /M5XX El> REMOVE EXISTING DAMPER AND ACTUATOR. ISOLATE DUCT FROM WALL SEE 1 /M5XX. PROVIDE DRYWALL FRAME FOR EXISTING GRILLES AND DIFFUSERS, WHERE LOCATED IN DRYWALL CEILING. PROVIDE ELBOWS WITH TURNING VANES. PROVIDE DUAL -DUCT VAV BOX, W -3, SEE VARIABLE AIR VOLUME TERMINAL UNIT SCHEDULE /M3. CONNECT TO EXISTING TRUNK DUCT. PROVIDE FLEX DUCT FOR FINAL CONNECTION TO THE DIFFUSER. SEE DETAIL X /M5XX. RECEIVpIp. CITY OF TUKINILA MAY 2 6 2011 PERMIT CENTER 2M13 2M10 2M14 2M11 =0) 2M12 KEY PLAN SCALE: NONE CD CURRENT REVISION J #12010 -10/11 SYMBOL DATE 05.02.11 CHECKED APPROVED TITLE BUILDING 9-,53 SHEET 2M12 JOB NO. COMP NO. 541 c It 540 —1 1/2" 1/2" 2 2M6 iM506 539 3"0 VALVED TEE W /BLIND FLANGE (TYP) UNLESS OTHERWISE NOTED 538 EISMIC BRACING LATERAL LONGITUDINAL 537 536 535 534 1/2" CHWS & R (UNDER RAISED FLR) 3" Are- Ade- AIMIIPf A IN 533 LINES RUN BELOW RAISED FLR �IJNISTRUT SUPPORT (NP) 529 0\ 528 3 1/2" If -- SEISMIC BRACING LATERAL LONGITUDINAL FUTURE 527 26 " 3/4" 2" DROP THROUGH FLR & CAP 2" 1 1/2" (/'1� 2M61 1M506 filS41 ea T)1) AC1C05A FUTURE 2" 4" 473 474 -.5 -.6 MATCHLINE —FOR CONTINUA ION SEE S—IT. 2M60 1\-3" XH'c) 2 1/2" CHWS & R ABOVE CEILING 2" 477 'EDPAC' A/C PROCESS COOLING UNIT 20— TON,MDL CD -8037 480V, 30 LIEBERT CHALLENGER 000 460V, BELOW RAISED FLOOR 491 14' -0" 11) 478— 184 481 -� 183 ir?■:11 TT I `; � ) 482- 1 1/4" 1" 486 485 483 484-1 CI IWR ) M -20 AC2E5 1Q TON LIE ERT MDL #UH24 C PIPING UNDER RAISED FLR (TYP) 1 242 ® 1 a 1+1 - .+o+ -_I c IJ 243 244 , 'e• X239 \I240 I _ 241 DN TO 1ST FLR CLG (6 TYP) FOR CONT SEE 1M61 IN CLG SPACE 487 488-1 489 ABOVE CEILING CHWR REVIEWED FOR C CDE COMPLIANCE APPROVED MAY 2 5 2011 City of Tukwila ByILDING QIUI.SI(1N 0 SECOND FLOOR PLA\ SCALE: 1/8' = 1' -0" 490 MATCHLINE —FOR CONTINUA ION SEE S —IT. 2M61 LIEBERT MD4UH2O0C 2" CHWS & RAISED FLR LEGE D GE \ERAL \OYES .i STRAINER: 1n MUELLER 125B, BRONZE, WITH ISOLATION AND ASS BALL VALVES. • SEE 4 /M5XX FOR CHWS &R CONNECTION DETAIL. REFERE \CE DRAWI \GS CONSTRUCTION NOTES INSTALL FLOOR— MOUNTED CRAC UNIT PROVIDED BY BOEING. INSTALL PER MANUFACTURER'S RECOMMENDATIONS. EQUIPMENT START —UP WILL BE PROVIDED BY EMERSON NETWORK POWER (CONTACT JAMES SWEET, 206 - 414 - 7999). CONNECT NEW 1-1/2" CHW TO EXISTING UNDER FLOR ROUTE TO NEW CRAC UNIT. 1" BRASS BASKET STRAINER 1" BALL VALVE — TYP • DIELECTRIC UNION BOTH ENDS OUTLINE OF 13 "W X 39 "L X 28 "H "HOT BOX" ENCLOSURE R DROP INTO C7) M 1N059 90% DESIGN REVIEW BRASS PIPING — P I _—I RECBV CITY 4F TUK' LA riM 2 3 2011 PERMIT CENTER PLAN VIEW 2M 63 2M60 2M64 KEY PLAN SCALE: NONE ,�BOE /NG' d� ACCEPTABILITY THIS DESIGN AND /OR SPECIRCATION IS APPROVED DRAWN AR DATE 8.5.85 CHECKED DPN 10.10.85 SUBTITLE CHILLED & HOT WATER PIPING CURRENT REVISION J #12010 -10/11 SYMBOL DATE 05.02.11 APPROVED BY DEPT. DATE ENGINEER CHECKED APPROVED TITLE BUILDING 9 -53 SHEET 2M61 JOB NO. COMP NO. BY APPROVED DATE SYM REVISION BY APPROVED DATE SYM REVISION — CONVERSION FROM MYLAR TO CAD CCSI 12.10.00 A CHWS STRAINER TO PAO COOLER 55676300 HARR RWS 12.07.09 B CHECK AC UNIT FOR BATTERY LAB 6132 RWS RWS 12.07.09 C THE DALLAS PROJECT 412010-10/11 FSi 05.02.11 490 MATCHLINE —FOR CONTINUA ION SEE S —IT. 2M61 LIEBERT MD4UH2O0C 2" CHWS & RAISED FLR LEGE D GE \ERAL \OYES .i STRAINER: 1n MUELLER 125B, BRONZE, WITH ISOLATION AND ASS BALL VALVES. • SEE 4 /M5XX FOR CHWS &R CONNECTION DETAIL. REFERE \CE DRAWI \GS CONSTRUCTION NOTES INSTALL FLOOR— MOUNTED CRAC UNIT PROVIDED BY BOEING. INSTALL PER MANUFACTURER'S RECOMMENDATIONS. EQUIPMENT START —UP WILL BE PROVIDED BY EMERSON NETWORK POWER (CONTACT JAMES SWEET, 206 - 414 - 7999). CONNECT NEW 1-1/2" CHW TO EXISTING UNDER FLOR ROUTE TO NEW CRAC UNIT. 1" BRASS BASKET STRAINER 1" BALL VALVE — TYP • DIELECTRIC UNION BOTH ENDS OUTLINE OF 13 "W X 39 "L X 28 "H "HOT BOX" ENCLOSURE R DROP INTO C7) M 1N059 90% DESIGN REVIEW BRASS PIPING — P I _—I RECBV CITY 4F TUK' LA riM 2 3 2011 PERMIT CENTER PLAN VIEW 2M 63 2M60 2M64 KEY PLAN SCALE: NONE ,�BOE /NG' d� ACCEPTABILITY THIS DESIGN AND /OR SPECIRCATION IS APPROVED DRAWN AR DATE 8.5.85 CHECKED DPN 10.10.85 SUBTITLE CHILLED & HOT WATER PIPING CURRENT REVISION J #12010 -10/11 SYMBOL DATE 05.02.11 APPROVED BY DEPT. DATE ENGINEER CHECKED APPROVED TITLE BUILDING 9 -53 SHEET 2M61 JOB NO. COMP NO. 1" PVC CONDENSATE DRAIN-. 2'X2' PLYWOOD PAINTED BLACK Y2" CW 561 % 4 "DN W/ BALL VALVE %" CD FS -1 (9) TYP 2" V DN 2" V DN cl =A v 3/4" CD 1Y "V DN 2" V 3/4" COND DRAIN 4" RL BTW ROOF JOISTS ABOVE DUCTS SLOPE ©1 /2 " /FT 191 FUTURE A/C UNIT 2" V V FLR MTD A/C UNIT FUTURE A/C UNIT 2x1 1/2" V DN 1/2" TRAP PRIMER 4" RL UP TO RD -1 2" V 2 "VDN v 1 /2" TRAP PRIMER �3" VTR 563 (THRU GRD PLANE) 2 1/2" V 2" V IN CLG SPACE (TYP) RL DN 1 1/2" V DN - 3/4" CD 1/2" TRAP PRIMER 3/4" CD DRAIN ON SUNKEN FLR (TYP) SECO \D FLOOR PLU SCALE: 1/8' = 1' -0" 573 VIBI\ 572 563 MATCHLINE -FOR CONTINUATION SEE SHT. 2M110 1/2" CW� AC2E5 10-TON---- "------3/4" CD n -�� 4" RL DN 4" RL BELOW SUPPLY /RETURN DUCTS & ABOVE CLG v 1 4 "RLUP TO RD -1 4" RL DN 1/2" TRAP PRIMER 1 1/2" V > �-1 1/2 "V G PLA\ 569 1 1/2" V DN IF LIEBERT MDL #UH2O0C II 4" RL DN & �UP TO RD -1 1 /2" TRAP PRIMER 3/4" DISCHARGE LINE WITH CHECK VALVE TO FLOOR SINK /2" DRAIN FROM AUTOMATIC AIR VENT MATCHLINE -FOR CONTINUATION SEE SHT. 2M112 SELF CONTAINED CONDENSATE PUMP CP -X MAY BE NEXT TO A/C UNIT BELOW RAISED FLOOR OR ATTACHED TO CLG HUNG UNITS W /BRACKET A/C UNIT FLOOR OR CLG MOUNTED COOLING COIL -DRAIN PAN BELOW COOLING COIL FLOOR TYPICAL PUMP DETAIL SCALE: NONE REVIEWED FOR CODE COMPLIANC E QDDROVED MAY 2 5 201 City of Tukwila BUILDINGnnncinM M (1%-oo ASBESTOS NOTIFICATION A GOOD FAITH SURVEY OF THE BUILDING HAS BEEN CONDUCTED AND NO ASBESTOS CONTAINING MATERIAL WAS DISCOVERED WITHIN THIS BUILDING. SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE CONVERSION FROM MYLAR TO CAD CCSI 12.10.00 A PROVIDE AIR DROP J # 711552 -00 DMV B DESIGN COMPRESSED AIR DROPS 10971894 M.WONG RWS 08.03.10 C THE DALLAS PROJECT 412010 -10/11 FSi 05.02.11 BOE //VG' ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED DRAWN TGT APPROVED BY DEPT. DATE CHECKED LMM ENCINEER DATE 8.30.85 8.30.85 SUBTITLE LEGE \D GENERAL NOTES 1. HVAC REFERENCE DRAWINGS (SHEET METAL) 1M10, 1M11, AND 1M12. 2. SEE ALSO A/C UNIT NOTES, SHEET M103. 3. TRAP PRIMER VALVE IN CLG SPACE W /THREE OPENING DISTRIBUTION UNIT. RUN 1/2" COPPER DISCHARGE LINES DOWN WALL AND ON SUNKEN FLR TO EACH FLOOR SINK (FS -1). (9) TYPICAL. CONSTRUCTION NOTES CONNECT EXISTING CD TO CRAC UNIT CONDENSATE PUMP DRAIN CONNECTION. CONNECT TO EXISTING TEE. PROVIDE ISOLATION VALVE. LOCATE EXISTING CA STATION ABOVE CEILING, SUPPORT FROM WALL. CONNECT TO EXISTING CA PIPING. Control Air (Pneumatic Control System) REFERENCE DRAWINGS RE CffY OF CEIV�p_ TUromLA MAY .232011 1 90% DESIGN REVIEW 1 PERMITCENTER SECOND FLOOR PLUMBING PLAN DD 2M113 2M 110 2M114 0 2M112 p KEY PLAN SCALE: NONE CURRENT REVISION J #12010 -10/11 SYMBOL DATE 05.02.11 CHECKED APPROVED TITLE BUILDING 9 -53 SHEET 2M111 JOB N0. COMP N0. LONGITUDINAL BRACE 501 BOLT DIA. PER SCHEDULE L60° DETAIL 3/4" = r-O" 4- WAY /2 -WAY BRACING BENT ?: BAR 3 1/2x1/4 TYPICAL OR UNISTRUT P 1546 LATERAL BRACE 2M261 M501 2x2x 1 /4"PLATE BOTTOM CHORD OF TRUSS 1/2" OR 3/8" ROD SWIVEL RING TYPICAL PIPE HANGER (2 SCALE: NONE 2M2611 1v1501 (FOR PIPES RUNNING PERPENDICULAR TO TRUSS JOIST) DIAMETER OF PIPE "0" LENGTH OF BRACE "L" LATERAL BRACE MATERIALS LONGITUDINAL BRACE MATERIALS BOLT DIA 0 < 4"0 < 8' UNISTRUT P1000 P1000 3/8 "0 8' -10' UNISTRUT P5500, J 3x3x1/4 P5500 10' -15' 3 "0 PIPE 3"0 PIPE 5 " -6 "� < 10' UNISTRUT P5500, J 3x3x1/4 P5500 2 MEMBERS REQ. 1/2 "0 10'-15' -15 , 3 N 0 PIPE 3"0 PIPE 8"-12"0 < 5' UNISTRUT P5500 P5500 2 MEMBERS REQ. 5/8 "0 FOR 80 PIPE 3/4 "0 FOR LARGER 5' -10' 2 "0 PIPE, / 3-1/2 x 3-1/2 x 1/4 2 "0 PIPE 2 MEMBERS REQ. 10' -15' 3 "0 PIPE 3"0 PIPE 2 MEMBERS REQ. GREATER THAN 12 "0 GREATER THAN 15' CONSULT W /ENGINEER CONSULT W /ENGINEER NOTE: 1. ALL BRACING MATERIAL LISTED ARE THE MINIMUN FOR EACH PIPE SIZE AND BRACE LENGTH. STRONGER MATERIALS MAY BE SUBSTITUTED. 6 2. ON 6 "0 AND LARGER PIPES ANY P1546 ANGULAR FITTINGS USED WILL REQUIRE TWO BOLTS FOR FASTENING THE FITTING TO THE UNISTRUT TO PREVENT SLIPPAGE. 3. A TWO -WAY LATERAL BRACE WOULD FOLLOW THE SAME BRACING SCHEDULE, BUT NO LONGITUDINAL MEMBER WOULD BE USED. A TWO WAY LONGITUDANAL BRACE WOULD NOT REQUIRE THE LATERAL MEMBER. 4. ALL FIRE SPRINKLER CROSS MAINS AND FEED MAINS SHALL BE LATTERALLY BRACED AT 40' -0" O.C. MAX AND LONGITUDINALLY BRACED 80' -0" 0.C. MAX. AS PER DRAWING. LATERAL BRACING MAY BE OMITTED IF PIPES ARE SUPPORTED BY RODS LESS THAN 6" LONG. SEE NFPA 13 FOR FURTHER DETAILS. EXIST CEILING BEAM LONGITUDINAL BRACE L YP LONGITUDINAL BRACE LATERAL BRACE VIEW N.T.S. NOTE: rc� 501 NOT ALL LONGITUDINAL BRACING REQUIRES TWO MEMBERS. REFERENCE ABOVE SCHEDULE FOR APPLICATIONS REQUIRING ONLY ONE LONGITUDINAL MEMBER. 10"0 18x18 (2) 14"x10" MOTORIZED FIRE��� DAMPERS Q ROOF 18X18 RETURN AIR GRILLE, TITUS 350RL W/ OBD 910 CFM *21' TO 24'1 ABOVE ACCESS FLOOR TILES 18x24 - 11.1.1 -1 - EXISTING 12' ABOVE ACCESS FLOOR EXISTING WALL TO REMAIN (A� 2M11 M501 S ECTI O SCALE: 1/2"=1'-0" ROOF 480CFM 10X12 �z SUPPLY AIR GRILLE, TITUS 300RL T .$21' TO 24'1 ABOVE ACCESS FLOOR 1LES SECTION SCALE: 1/2"=1'-0" . EXISTING 12' ABOVE ACCESS FLOOR EXISTING WALL TO REMAIN 1 /2 "SQ WIRE MESH BETWEEN CROSS BARS 1/2"SQ WIRE MESH BETWEEN CROSS BARS 1/2"O STEEL BAR SYM REVISION A RELOCATE P730 TO Z -1 LAB BY KGP /RWS APPROVED DATE SYM REVISION BY APPROVED DATE EJC B EPME DESIGN F -22 TRAINING LAB 9575682 M.WONG RWS 10.06.09 C THE DALLAS PROJECT J #12010 -10/11 FSi 05.02.11 BOE /A/G' ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED DRAWN K. PENROD CHECKED DATE 05.27.95 SUBTITLE (B 2M11 M501 , REVIEWED FOR OODE COMPLIANCE A°DROVED MAY 25 1611 City of Tukwila BUILDINR nivIcinMM LEGEND GE \ERAL NOTES CONSTRUCTION \OTES REFERENCE DRAWINGS M(k0S9 90% DESIGN REVIEW 1 SECTIONS & DETAILS CITY OF TaLA MAY :2 3 2011 PERMIT CENTER CURRENT REVISION J #12010 -10/11 SYMBOL DATE 05.02.11 APPROVED BY DEPT. DATE ENGINEER CHECKED APPROVED TITLE BUILDING 9 -53 SHEET M501 JOB NO. 157075 -00 COMP NO. STRAPS OF ISOLATOR HANGERS AS REQUIRED CAULK OPENINGS FROM WALL SURFACE TO DUCT OR CONDUIT WITH NON HARDENING ACOUSTICAL SEALANT BOTH SIDES OF WALL USE FIRE -RATED SEALANT AS REQUIRED. MAN -BARS, SEE 3/M501 FOR CONFIGURATION. WELD AT ALL CROSS AREAS PACK ANNULAR SPACE COMPLETELY WITH MINERAL FIBER OR BULK CERAMIC FIBER AS REQUIRED FOR FIRE RATING. RECESS FIBROUS MATERIAL INTO SLEEVE 0.5 IN OR AS REQUIRED BY THE SPECIFIC U.L.SYSTEM FOR REQUIRED SEALANT THICKNESS. LOCKABLE ACCESS HANDHOLE W/ INSET VIEWING PANEL METAL SLEEVE 0.5" TO .75" LARGER THAN OUTSIDE DIMENSION OF DUCT. 9 GAUGE DUCT SECTION WITH 1 STEEL MANBARS BLY FOR DUCT OF SECURE AREAS - DETAIL SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE A THE DALLAS PROJECT J #12010 -10/11 FSi 05.02.11 giASFAIEIAW ® a� ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED DRAWN DATE APPROVED BY DEPT. DATE CHECKED NCINEER SUBTITLE REVIEWED FOR , E COMPLIANCE 'PROVED MAY 2 5 ail City of Tukwila BUILDING nil/ mink, M(kOS1 90% DESIGN (VIEW R�GEIT � CITYdF LA MAY 2 3 2011 PERMIT CENTER DETAILS CURRENT REVISION J #12010 -10/11 SYMBOL A DATE 05.02.11 CHECKED APPROVED TITLE BUILDING 9 -53 SHEET M504 JOB NO. COMP NO. FABRICATE INTERIOR FRAME FROM 2" X 1/4" FLAT BAR TO FIT SNUG INSIDE DUCT - -____,,, WELD 1/2" DIA. CROSS BARS TO INTERIOR FRAME & AT BAR INTERSECTIONS 5" O.C. EACH DIRECTION -- 3/8" DIA. CARRIAGE BOLT 24" O.C. OR 2 EACH SIDE MINIMUM, THRU INTERIOR FRAME TO EXTERIOR FRAME WITH BOLT HEAD ON INSIDE OF THE DUCT. DISTRESS THE THREADS AFTER ASSEMBLY. 0 0 0 0 L -- 0 -- FABRICATE EXTERIOR FRAME FROM 2" X 2" X 1/4" ANGLE 0 SECURITY GRILLE DETAIL 1/2" WIRE MESH SCREEN (HARDWARE CLOTH) POSITIONED BETWEEN CROSS BARS SECURE HARDWARE CLOTH WITH 16 GA. SHEET METAL ANGLE (POP RIVET TO FLAT BAR & WELD AT EACH CROSS BAR.) (6 NO SCALE M -505 M -505 EXTERNAL PIPE JOINT DIELECTRIC - -� 6 "MAX. CEILING ALL OR ` DIELECTRIC SLEEVE \ j /41 (ONE PER BOLT) - ---„, SLEEVE DIELECTRIC WASHER / (TWO PER BOLT)-----/' SECURE AREA-1 WALL PENETRATION DETAIL 1 L2 1/2"SIZE & LARGER PRESSURE PIPING WATER( *),GAS,AIR L- UNSECURED AREA (3 NO SCALE 1M -113 M -505 ( *) DOMESTIC,CHILLED AND FIRE MAINS DIELECTRIC UNION SECURE AREA SLEEVE STEEL PIPE OR COPPER TUBE FOR WATER( *),GAS,AIR PRESSURE SYSTEM 2" SIZE & SMALLER 40 DB GB WALL OR CEILING 6 "MAX UNSECURE AREA WALL PE \ETRATIC\ DETAIL NO SCALE ( *) DOMESTIC,CHILLED AND FIRE MAINS (2)L 212 "X 2 "X X16 "BRACING ENCLOSED BY FIELD MOUNTED 20 GA.GALV.SHT.STL.SPACER -- 40 OR 45 DB WALL- --\ DUCTWORK -- AS CLOSE AS POSSIBLE (12" MAX.) 1 SECURITY GRILLE SEE DETAIL SECURE AREA DUCT LINER DUCT SILENCER UNSECURED AREA -- ACCESS PANEL \-----DIELECTRIC ISOLATION (FLEXIBLE CONNECTOR) WALL PENETRATION DETAIL NO SCALE 12' (5 M -505 M -505 11 COL. LINE AHU -55 �— 24 "X 30" EXHAUST / DISCHARGE BEYOND 1 OPENING & DAMPER IN RET.AIR PLENUM ROOF(REF.) SQUARE OR RECTANGULAR BRANCH TAKE -OFF --ROOF TRUSS AT COL.B.5 6 "DEEP CHANNEL SUPPORT (REF.ONLY) LCUTOUT (2) IN SPACER TO FACILITATE SEALING OF PENETRATING in BRACING & TO CLEAR GUSSET PLATE SPACER DETAIL SCALE:1 /2" =1'-O" ATTACH 16" WIDE SPACER TO OSA & EXHAUST AIR PLENUMS & SEAL. METHOD OF FASTENING SHALL BE THE SAME AS FACTORY MOUNTED SECTIONS. BLANK OFF & SEAL CUTOUT OPENINGS IN SUPPLY RETURN PLENUMS (4)LOCATIONS —0" PLATFORM PLATFORM EL. 114' -6" tit (i%19 5-43 SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE A ISSUE FOR CONSTRUCTION APH M. WON PJD MING 04 -29 -88 B THE DALLAS PROJECT J #12010 -10/11 FSi 05.02.11 g)LAFISIEZAW ® ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN SRL CHECKED LM M ENCINEER LMM DATE SUBTITLE 90% DESIGN REVIEW DETAILS CORDEVIMED FOR E COMPLIANCE A DPROVED MAY 25t 11 City of Tukwila BUILDIN flIvI �r CITY TIUKI ILA MAY:2 2011 PERMIT CENTER CHECKED SEL APPROVED TITLE BUILDING 9 -53 CURRENT REVISION J #12010 -10/11 SHEET SYMBOL DATE 05.02.11 M638 JOB NO. COMP NO. E.5 F.6 14x10 22x18 20x12 86x50 •>• ��— ∎■orit 1310 65 20x12 14x10 20x16 RAR -1 22x18 420 RAR -1 420 RAR -1 800 18x12 960 18x12 60 20x14 100 CFM 20x18 VD (H) 80CFM 12X10 SUPPLY AIR GRILLE, TITUS 300RL CAP RAR — 1390 RAR -1 715 CFM 15x8 j I VD 24x22 22x15 1111111F:i!W Z3C 20x18 40x28 16x10 C4) L.1 62x37 (H) 28x18 22x18 14 "0 MAN BARS & ACCESS DOOR 10"0 910CFM, 18X18 RETURN AIR GRILLE, TITUS 350RL W/ OBD & MOTORIZED FIRE DAMPERS IN1 ._. 2M11 M501 72x42 20x14 AR -1 15 CFM VD 20x16 22x14 1670 58 22x14 14x10 VD 550 16x10 RAR -1 610 CFM VD 14x12 18x14 VD 20x14 14x10 560 VD 550 14 14 14x10 RAR -1 800 800 15 20x14 Z3D 9 14x12 610 10 18x12 —� RAR -1 610 CFNM 16x10 430CFM 12X10 SUPPLY AIR GRILLE, TITUS 300RL 16x12 18x12 64x32 L04 ED CLo ►ED 22x16 16x12 RAR -1 310 CF �-18X 1 72x42 RAR 1 1390 CFM 770 VD 10 74x42 1120 14x11 55 11x11 22x11 VD (H) 14x11 24x20 AR -1 00 CFM 15x10 500 8 Iri1F' •1113 RAR -1 1390 CFM BOTTOM AT 25' —0" AFF 42X37 30' — DOME SIM SEE DIA LATOR (F- WG. 1M51 RAR -1, 440 CFM 17X14 —' Lfla 16x10 1 560 CFM 14x10 E1111111101111 22x16 440 8 12x9 RAR -1 310 CFM 20x14 RAR -1, 1390 CFM 32x12 It SW RAR -1 560 CFM 32x26 16x14 10x10 VD,,�r� 14X1 VD 32x18 26x14 VD 840 10 14x14 DO N AND CONNECT TO DIFFUS C UNIT MODEL CSF I 2360CFM I§ .75 "SP Orr RAR -1 1391 20x1 A--14x 10 20x16 1500 1500 46 47 24x18 EMS MOON BMA WAN MEM R 26x16 DN (H) 18x16 RAG -1, 1 80 CFM, MOUNT 10FT. AFF 62x32 20TON EDPAC 92 "X33" BOEING 07502594 26x12 32x22 26x12 1 N■■ NOM R -1 51 380 CFM 4x10 6 18x14 575 14 VD RAR -1 =NIL. 1150 CFM BOTTOM A T 24x18 24x18 1150 24x14 — VD 62x32 RAR -1 VD 560 CFM 575 14 VD 660 24x14 16x10 14x13 16x12 RAR— 1 1125 CFM 22x13 1 16x12 22x16 ' 18x14 30x20 15 RAR - 510 C 6x10 MN, ■ V •' R 60 18x12 16x12 DOWN 430 8 13x10 12x9 4x10 22x16 RETURN AIR, 186 BOX FOR (3) FILT INSTALLED ABOVE 20x16 Mir* w1 30x20 16x12 22x16 24x22 SECOND FLOOR HVAC PLA\ SCALE: 1 /8' =1' -0" 310 CFM SYM N R S REVISION BY APPROVED DATE SYM REVISION APPROVED DATE INSTALL RETURN AIR DIFFUSER D.M.V. R.W.S. 1.7.00 U E5118 —EPME DESIGN F -22 TRAINING LAB 9575682 M.WONG RWS 10.06.09 INSTALL MOTOR DRIVES J#775361 —04 S.L.B. E.J.C. 3.16.98 V THE DALLAS PROJECT J #12010 -10/11 FSi 05.02.11 INSTALL DIFFUSER J #700009 —LO D.M.V. R.W.S. 1.7.00 CONVERSION FROM MYLAR TO CAD CCSI 12.10.00 Q� BOE /NG' o'— REMOVAL ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN Y.L. CHAN CHECKED D.P.N. ENCINEER DATE 9.20.85 10.10.85 SUBTITLE 7.5 LEGE \D INDICATES MAN BARS TO BE INSTALLED IN DUCT INDICATES LOCATION OF CAPACITANCE GRID AND LOCKABLE ACCESS WITH INSET VIEWING PANEL ACCESS FOR DUCT CLEANING GE \ERAL \OTES RE v OVAL OYES RETAIN DUAL —DUCT TERMINAL UNIT FOR INSTALLATION AT NEW LOCATION. DUCT WITH MAN —BAR INSPECTION VIEWPORT SHALL REMAIN. D> RETAIN DIFFUSERS AND GRILLES FOR INSTALLATION AT NEW LOCATION. WALL SHALL BE PATCHED /REPAIRED TO MEET STC REQUIREMENTS, SEE ARCH. DISCONNECT EXISTING CRAC UNIT AND PROVIDE SALVAGED UNIT TO BOEING. DISCONNECT AND CAP CONNECTIONS TO CHILLED WATER SUPPLY /RETURN FOR REUSE. R WREV ED O CCODE COMPLIANCE A 3 ROVED MAY 2tiO City of Tukwila BUILDINP n fIllcInk, REFERENCE DRAWI \GS REGEIVf�. CIT/dFTUKn�nLA MAY 0 61011 PERMIT CENTER VI I V-O51 90% DESIGN REVIEW SECOND FLOOR HVAC PLAN 2M 3 2M14 2M10 (D 2M12 r KEY PLAN SCALE: NONE CURRENT REVISION J #12010 -10/11 SYMBOL ` ! DATE 05.02.11 CHECKED APPROVED TITLE BUILDING 9 -53 SHEET 2M11R JOB NO. COMP NO. A6 1460 11 37 9C), 640 38 62x RAR -1 960 CFM Boy C5 D.% 25 —.4 —.5 22x16 730 RAR -1 730 CFM 320 8 14x8 CF 640 CF 20x18 46x32 14x10 12x9 16x12 H 38x26 RAR -1 310 CFM 480 8 30x20 i ■ 32x26 Ifg1 • �' 70 \\ ■'��(20x`- i ►I�„►A";t�''• 180 (H■ -- , 10 % w R� CFM �� 340 G I. � @i�7�■ i� 18x1 40 -. F �p'l`�7► , �� 70 CF M 9x14 i 01 Ai r4 ,lgtlia,41 . ;i(;Irii /i: /..: / / / / /ir 41 um All VD ® ►' , 18 10 W II / *//// I S ■���� . -- . . AL 30x20 PACE A/C UNIT 12" 2360 CFM © .50 SP MODEL SCF 114 —B MI 8 "o INL PESV W/ TITUS 24X18 14' -0" A.F.F. itg :.!1 MIME IL Kt I ■IWINIIIIMIllWa= w_r - Yet ! 11111111■■-1"41- ►�ENNUI. © 1 Ilk 1lli�'�:y, 111111L■■. 1 MIL II A.F.F. 14X12 14' -0" A.F.F. IAEA 711 ��• .." �� VD iI_ <G0 8 \'.L =1[ 480 kir . ∎ = 18x10 10 RAR -1 560 CFM 16x10 1860 1860 30x20 6 42 • 22x1 BOTTOM AT 30' -0" AFF 15 22x16 RAR 310 CFM 20x14 RETURN AIR, 1860 CFM W/ FILTER BOX FOR (3) COALESING FILTER RACKS. MANUAL DAMPER ABOVE FILTER ITRANlS1TI0N. -+ i ■11 ,30x20 20x14 22x16 1,390CFM RAR -1 (TYP. OF 2) 111 N VD VD .■ 32x20 2780 20x14 36 RAR -1, 1390 CFM 28x15 12 "0 590 CFM TITUS XC -310 (TYP. OF 4) rimmi P.O.C. 12 "0 550 CFM i C -310 TYP. OF 2) 32x14 23x14 18x12 2112 1111504 RAR -1 950 CFM 18x12 RAR -1 950 CFM 30' -0" DOME SIMULATOR SEE DWG 1M512 16 "0 ELBOW DN TO A/C UNIT 14 "0 840 CFM TITUS XC -310 (TYP. OF 2) 26 1/2 x 16 1/2 DN 18x16 RAG-1, 1680 CFM MOUNT 10 FT AFF 12 BOTTOM OF SUPPLY & RETURN DIFFUSERS IN THIS AREA TO BE 12' -0" AFF MANBAR ASSEMBLY SHALL BE FURNISHED AT EVERY DUCT PENETRATION OVER 90 SQ. IN. THROUGH WALLS SURROUNDING SECURE AREAS. (INDICATED BY SHADING) SEE DETAIL BOTTOM AT 25' -0" AFF 26 1/2x16 2M1211 M517 18x16 RAG -1, 1680 CFM MOUNT 10 FT AFF REMOVAL 8� SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED H INSTALL MOTOR DRIVE 4775361 -04 S.L.B. E.J.C. 3.16.98 M DOME REMOVAL J #150655 -00 M.WONG RWS J NEW RM ® B9 -8 RA GRILLS J #792418 R.A.D. R.W.J. 7.8.99 N RELOCATE BATTERY LAB 6132 RWS RWS CONVERSION FROM MYLAR TO CAD CCSI 12.10.00 0 THE DALLAS PROJECT J #12010 -10/11 FSi DATE 06.13.06 12.07.09 05.02.11 K INSTALL DAMPERS AND BALANCE SYSTEM 545931 -00 RWS RWS 03.26.04 i W"VG' ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN Y.L. CHAN CHECKED D.P.N. ENCINEER DATE 9.20.85 10.10.85 SUBTITLE 10.3 1005 11 GEC ERAL \OYES 1. ALL DUCT SIZES SHOWN ARE INTERNAL CLEAR DIMENSIONS WITH ONE INCH SOUND LINING IN THE INSIDE OF ALL SUPPLY, RETURN AND EXHAUST DUCTWORK. 2. FOR EXACT LOCATIONS OF SUPPLY AND RETURN DIFFUSERS SEE ARCH. REFLECTED CEILING PLANS. 3. MOTORIZED DAMPERS FOR HALON FIRE SUPPRESSION SYSTEM TO BE LOCKED BACK TO RELEVANT ZONE HALON CONTROL PANEL BY CONTROL CONTRACTOR INDICATES MANBARS IN DUCT INDICATEDS LOCATION OF CAPACITANCE GRID AND 47 LOCKABLE ACCESS WITH INSET VIEWING PANEL RE ACCESS FOR DUCT CLEANING VIM/AL COTES RETAIN DIFFUSERS FOR INSTALLATION AT NEW LOCATION. DUCT WITH MAN -BAR INSPECTION VIEWPORT SHALL REMAIN. WALL SHALL BE PATCHED /REPAIRED TO MEET STC REQUIREMENT, SEE ARCH. CODE REVI�WE p FOR COMPLIANCE A" 'ROVED MAY 252;ii city of Tukwila B UILDING niCIn nl till%0059 90% DESIGN R VIEW HVAC - SECOND FLOOR PLAN RECEIV ;.. CITY OF TU LA MAY 06 2011 PERMIT CENTER 2M 3 2M10 2M14 2M11 7-0 KEY PLAN SCALE: NONE CURRENT REVISION J #12010 -10/11 SYMBOL 0 DATE 05.02.11 CHECKED APPROVED TITLE BUILDING 53 SHEET 2M12R JOB NO. COMP NO. oq c.)t-4- 1 541 H 2» 540 '73" O1_ _0 ( 1 1/2" 3 1/2" 2 2M61 1 M506 539 3"0 VALVED TEE VV/BLIND �— FLANGE (TYP) UNLESS OTHERWISE NOTED 538 SEISMIC BRACING LATERAL LONGITUDINAL 537 536 1 1/2" CHWS & R (UNDER RAISED FLR) 3" i LINES RUN BELOW RAISED FLR UNISTRUT SUPPORT (TYP) 0 )II RR. Ar 529 528 3 1/2" 3" SEISMIC BRACING LATERAL LONGITUDINAL FUTURE 527 2" DROP THROUGH FLR & CAP 'EDPAC' A/C PROCESS COOLING UNIT 20- TON,MDL CD -8037 480V, 30 1 1/2" 2M61 1M506 ACICOSA FUTURE ff 4" 4734 111141 4747 MATCHLINE -FOR CONTINUAtION SEE SHT. 2M60 2 1/2" CHWS & R ABOVE CEILING 2" 475 477 478 'CONTEMPO' MDL CEMC -1234 S/N 21156 460V, 30 184 � 481 - I ii ITT1()() 482-' 1 1/4" 1" 14' -0" 1-=14 ) 183 21 C7 491 26 OPEN PLENUM BELOW COMP. FLR (AS FIELD CHK) 492 T (-) 486 485 483 484J 23C7 ) ) it AC2E5 19-TON LIE ERT M L #UH24 CM -20 � I PIPING UNDER RAISED FLR (TYP) 242 DcH l 243 � 239 240 241 DN TO 1ST FLR C G (6 TYP FOR CONT SEE 1 M•1 244 IN CLG SPACE 487 I 488-" 25C7 24C7 SECO \D FLOOR PLA\ SCALE: 1/8' = 1' -0" 489 490 REVIEWED OR CODE COMPLIANCE a AOoROVED '~,) 2 5 2011 City of Tukwila BUILDING DIUrgIIDn, LIEBERT MDL #UH200C MATCHLINE -FOR CONTINUATION SEE SHT. 2M61 2" CHWS & RAISED FLR REMOVAL SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE CONVERSION FROM MYLAR TO CAD CCSI 12.10.00 A CHWS STRAINER TO PAO COOLER 55676300 HARR RWS 12.07.09 B CHECK AC UNIT FOR BATTERY LAB 6132 RWS RWS 12.07.09 C THE DALLAS PROJECT J #10210 -10/11 FSi 05.02.11 OISIU rE,AW ® ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN AR CHECKED DPN ENGINEER DATE 8.5.85 10.10.85 SUBTITLE R DROP INTO LEGEND GE\ ERAL COTES STRAINER: 1" MUELLER 1258, BRONZE, WITH ISOLATION AND BYPASS BALL VALVES. REFERENCE DRAWI \CS REMOVAL OYES DISCONNECT CHILLED WATER SUPPLY AND RETURN, AND PREPARE FOR CONNECTION TO NEW UNIT. REMOVE EXISTING CRAC UNIT AND RETURN TO BOEING. 1" BRASS BASKET STRAINER 1" BALL VALVE - TYP DIELECTRIC UNION BOTH ENDS OUTLINE OF 13 "W X 39 "L X 28 "H "HOT BOX" ENCLOSURE M ll%i-osq 1 90% DESIGN REVIEW , BRASS PIPING - T�'P FRONT VIEW U cITY RE oGEIf TU C V LA MAT 06 2011 PERMIT CENTER PLAN VIEW 2M63 2M60 2M64 2M62 p KEY PLAN SCALE: NONE 0 (ij) CHILLED & HOT WATW PIPING CURRENT REVISION J #12010 -10/11 SYMBOL DATE 05.02.11 CHECKED APPROVED TITLE BUILDING 9 -3 SHEET 2M61 R JOB NO. COMP NO. 1" PVC CONDENSATE DRAIN 4" 2'X2' PLYWOOD PAINTED BLACK [ 1 1 % 4 "DN W/ Y" CW 561 BALL VALVE 3/4" CD FS -1 (9) TYP c 2 "VDN ��- 2" V DN 3/4" CD 1Y "V DN 2" V 3/4" COND DRAIN 4" RL BTW ROOF JOISTS ABOVE DUCTS SLOPE 01 /2 " /FT FUTURE A/C UNIT 2" V 4" RL UP TO RD -1 v v 1 /2" TRAP PRIMER 3" VTR 563 (THRU GRD PLANE) ��- FUTURE A/C UNIT FLR MTD A/C UNIT 1/2" TRAP PRIMER 2 1/2" V 2 "VDN v 1 1/2" V DN RL DN 2 "" V 2" V IN CLG SPACE (TYP) v 572 563 19MCHLINE -FOR 4" RL BELOW SUPPLY /RETURN DUCTS & ABOVE CLG v SECO \D FLOOR PLU v 1/2" TRAP PRIMER 3/4" CD DRAIN ON SUNKEN FLR (TIP) BI \G PLA 1/2" TRAP PRIMER 1/2" V �v 569 573- 1 1/2" TRAP PRIMER 3/4" DISCHARGE LINE WITH CHECK VALVE TO FLOOR SINK SELF CONTAINED CONDENSATE PUMP CP -X MAY BE NEXT TO A/C UNIT BELOW RAISED FLOOR OR ATTACHED TO CLG HUNG UNITS W /BRACKET 4" RL DN 4" RL UP TO RD -1 RL DN -.5 CONTINUATION SEE SHT. 2M1 10 -6 1/2" CW� AC2E5 AC2E5 10 -TON -- 1 1/2" V DN N`L-- 3/4" CD LIEBERT MDL #UH2O0C 4" RL DN & UP TO RD -1 jr/2° DRAIN FROM AUTOMATIC AIR VENT i MATCHLINE -FOR CONTINUATION SEE SHT. 2M112 A/C UNIT FLOOR �OR CLG MOUNTED COOLING COIL DRAIN PAN BELOW (,,---DRAIN COIL FLOOR •-- TYPICAL PUMP DETAIL SCALE: NONE SYM REVISION CONVERSION FROM MYLAR TO CAD BY CCSI APPROVED DATE SYM REVISION BY APPROVED DATE 12.10.00 A PROVIDE AIR DROP J # 711552 -00 DMV B DESIGN COMPRESSED AIR DROPS 10971894 M.WONG RWS 08.03.10 C THE DALLAS J #12010 -10/11 FSi 05.03.11 �BOE /iVG' CY- 4.9 5) 6% M(14) ASBESTOS NOTIFICATION A GOOD FAITH SURVEY OF THE BUILDING. HAS BEEN CONDUCTED AND NO ASBESTOS CONTAINING MATERIAL WAS DISCOVERED WITHIN THIS BUILDING. REMOVAL 90% DESIGN REVIEW LEGEND GE \ERAL \OTES 1. HVAC REFERENCE DRAWINGS (SHEET METAL) 1M10, 1M11, AND 1M12. 2. SEE ALSO A/C UNIT NOTES, SHEET M103. 3. TRAP PRIMER VALVE IN CLG SPACE W /THREE OPENING DISTRIBUTION UNIT. RUN 1/2" COPPER DISCHARGE LINES DOWN WALL AND ON SUNKEN FLR TO EACH FLOOR SINK (FS -1). (9) TYPICAL. RENOVAL NOTES DISCONNECT CD FROM EXISTING CRAC UNIT, AND PREPARE FOR CONNECTION AT NEW UNIT. REMOVE CA PIPING IN WALL, RELOCATE CA STATION TO ABOVE CEILING. SEE ARCH FOR WALL PATCH /REPAIR TO MEET STC REQUIREMENTS. REFERE ,0 EVIEWEI- FOR OE COMPLIANCE hY 2 ;`i 1 City of Tukwila S IJILflINs nom►nni \CE DRAWINGS RECEIV� CITYOFTU LA MAY D 6 2011 PERMIT CENTER 2M113 2M110 2M114 1ZM111 tr. (D 2M112 Lj KEY PLAN SCALE: NONE ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN TGT CHECKED LMM ENGINEER DATE 8.30.85 8.30.85 SUBTITLE SECOND FLOOR PLUMBING PLAN CURRENT REVISION J #12010 -10/11 SYMBOL DATE C 05.03.11 CHECKED APPROVED TITLE BUILDING 9 -53 5X� 2MIIIR JOB NO. COMP NO.