Loading...
HomeMy WebLinkAboutPermit M11-063 - EMBASSY SUITESEMBASSY SUIES 15920 WEST VALLEY HY M11-063 City okukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206- 431 -2451 Web site: http: / /www.TukwilaWA.gov MECHANICAL PERMIT Parcel No.: 0005800024 Address: 15920 WEST VALLEY HY TUKW Project Name: EMBASSY SUITES Permit Number: M11 -063 Issue Date: 05/17/2011 Permit Expires On: 11/13/2011 Owner: Name: KOAR - SEATAC PARTNERS LP Address: C/O HASEMAN AMERICA INC , 370 AMAPOLA AVE #210 90501 Contact Person: Name: JESICA ROGERS Address: 1221 2 AV N , KENT WA 98032 Email: JROGERS @HERMANSON.COM Contractor: Name: HERMANSON COMPANY LLP Address: 1221 2ND AV N , KENT, WA 98032 Contractor License No: HERMACLOO5BJ Phone: 206 - 575 -9700 Phone: 206 - 575 -9700 Expiration Date: 08/25/2012 DESCRIPTION OF WORK: INSTALL A NEW SELF CONTAINED DEHUMIDIFICATION UNIT AND (1) EXHAUST FAN, INSTALL NEW ALUMINUM DUCT WORK AND ELECTRIC DUCT HEATER. Value of Mechanical: $19,280.00 Type of Fire Protection: UNKNOWN Electrical Service Provided by: Permit Center Authorized Signature: Fees Collected: $428.56 International Mechanical Code Edition: 2009 j6 (i2 \ Date: OS)//7// I I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this permit. Signature: Print Name: 13 r Date: 01 7-z ! This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -4/10 M11-063 Printed: 05 -17 -2011 • PERMIT CONDITIONS Permit No. M11 -063 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements', of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431- 3670). 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431- 3670). 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City,of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IMC -4/10 M11 -063 Printed: 05 -17 -2011 • CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http: //www. ci. tukwila. wa. us Mechanical Permit No. IA —0 le Project No. (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: 15920 West Valley HWY Tenant Name: Embassy Suites King Co Assessor's Tax No.: 000580 -0024 Suite Number: Floor: New Tenant: ❑ Yes ®..No Property Owners Name: Embassy Suites / William Leverenz Mailing Address: 15920 West Valley HWY, Tukwila, WA 98188 City State Zip CONTACT PERSON — Who do we contact when your permit is ready to be issued Name: Jesica Rogers Mailing Address: 1221 2nd Ave N Day Telephone: (206) 575 -9700 Kent WA 98032 E -Mail Address: jrogers @hermanson.com City State Fax Number: (206) 575 -9800 Zip MECHANICAL CONTRACTOR INFORMATION Company Name: Hermanson Co LLP Mailing Address: 1221 2nd Ave N Kent WA 98032 Contact Person: Jesica Rogers E -Mail Address: jrogers @hermanson.com Contractor Registration Number: 05 -208 City State Zip Day Telephone: (206) 575 -9700 Fax Number: (206) 575 -9800 Expiration Date: 12/31/2010 ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: Mailing Address: Contact Person: E -Mail Address: City Day Telephone: Fax Number: State Zip ENGINEER OF RECORD = All plans must be wet stamped by Engineer of Record Company Name: Hermanson Company Mailing Address: 1221 2nd Ave North, Kent, WA 98032 Contact Person: Carol Sherman E -Mail Address: csherman @hermanson.com H:\Applications\rotms- Applications On Line \2009 Applications \I -2009 - Mechanical Permit Application.doc Revised: I -2009 bh City State Zip Day Telephone: (253) 796 -5868 Fax Number: Page 1 of 2 • o Valuation of Project (contractor's bid price): $ 19,280 Scope of Work (please provide detailed information): install a new self contained dehumidification unit and (1) exhaust fan, install new aluminum duct work, and electric duct heater. Use: Residential: New ❑ Replacement ❑ Commercial: New ® Replacement ❑ Fuel Type: Electric Gas ❑ Other: Indicate type of mechanical work being installed and the quantity below: Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: 0 -3 HP /100,000 BTU Qty Furnace <100K BTU Air Handling Unit >10,000 CFM Fire Damper Furnace >100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or addition to Heat/Refrig/Cooling System Incinerator — Domestic Other Mechanical Equipment I Air Handling Unit <10,000 CFM Incinerator — Comm/Ind PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY B LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDIN OWNER OR AUT , O ri .. D A Signature 1 (___ Print Name: Jesica Rogers 11 Mailing Address: 1221 2nd Ave N Date: 06/11/2011 Day Telephone: (206) 575 -9700 Kent WA 98032 City State Zip Date Application Accepted: Date Application Expires: Staff Initials: w_ I H:\Applications \Forms - Applications On Line\2009 Applications \I -2009 - Mechanical Permit Application.doc Revised: 1 -2009 bh Page 2 of 2 IIP 0 • C w City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone:206- 431 -3670 Fax: 206 - 431 -3665 8 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 0005800024 Address: 15920 WEST VALLEY BY TUKW Suite No: Applicant: EMBASSY SUITES RECEIPT Permit Number: M11 -063 Status: PENDING Applied Date: 05/11/2011 Issue Date: Receipt No.: R11 -00945 Payment Amount: $428.56 Initials: WER Payment Date: 05/11/2011 10:30 AM User ID: 1655 Balance: $0.00 Payee: JESICA ROGERS TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 211192 ACCOUNT ITEM LIST: Description 428.56 Account Code Current Pmts MECHANICAL - NONRES PLAN CHECK - NONRES 000.322.102.00.00 342.85 000.345.830 85.71 Total: $428.56 doc: Receipt -06 Printed: 05 -11 -2011 + , • INSPECTION RECORD Retain a copy with permit . CITY OF TUKWILA BUILDI 6300 Southcenter Blvd., #100, Tukwila. WA 98188 It (206) 431-3670 DIVISION • Permit Inspection Request Line (206) 431 -2451 "1 '/A 06 PERMIT NO. Project: `AIgliSSei S 7i / •->-S - Type of Inspection: r A/I L Address: ..' 90Z6 itiAsT r/'► //x- ' Date Called: Special InstrOctions: • • Date Wanted :. ,/D — 7 - // p.m. Requester: Phone No: o?OG -57 / -63 b. Approved per applicable codes. COMMENTS: DCorrections required prior to approval. Sh • ■ • • tEl PECTION FEE REQUIRED. Prior to xt inspection. fee must be • id,at 6300 Southcenter Blvd.. 5 ite 100. Call to schedule reinspection. JESICA ROGERS 1221 2 AV N KENT WA 98032 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director RE: Permit No. M11 -063 EMBASSY SUITES 15920 WEST VALLEY HY TUKW Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 11/13/2011. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 11/13/2011, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, c Bill Rambo Permit Technician File: Permit File No. M11 -063 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 PE THr1COP COM PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M11 -063 PROJECT NAME: EMBASSY SUITES SITE ADDRESS: 15920 WEST VALLEY HY X Original Plan Submittal Response to Incomplete Letter # DATE: 05 -11 -11 Response to Correction Letter # Revision # After Permit Issued DEPARTMiNTg:. , \ Belding Division Iii Public Works n ire Prevention Structural Planning Division Permit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete n DUE DATE: 05-12-11 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS TING: Please Route Structural Review Required ❑ No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Notation: Approved with Conditions DUE DATE: 06 -09 -11 Not Approved (attach comments) REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 Contractors or Tradespeople ter Friendly Page 0 General /Specialty Contractor A business registered as a construction contractor with Lai to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name HERMANSON COMPANY LLP UBI No. 602004844 Phone 2065759700 Status Active Address 1221 2Nd Ave N License No. HERMACLOO5BJ Suite /Apt. License Type Construction Contractor City Kent Effective Date 1/11/2000 State WA Expiration Date 8/25/2012 Zip 980322945 Suspend Date County King Specialty 1 General Business Type Limited Liability Partnership Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status HERMAC'016RN HERMANSON CORPORATION Construction Contractor General Unused 1/11/2000 8/21 /2002 Archived HERMAC'217NT HERMANSON CORPORATION Construction Contractor Air Heat,Ventilation,Evaporat Metal Fabrication 8/30/1979 8/21/2000 Archived Business Owner Information Name Role Effective Date Expiration Date NICOLAISEN, KNUT H Partner /Member 08/05/2010 Bond Amount BROCK, DANIEL L Partner /Member 08/05/2010 929381801 FOX, DEAN M Partner /Member 08/05/2010 HENGEL, STEPHEN A Partner /Member 08/05/2010 TRAVELERS CAS a SURETY CO DYCKMAN, KENNETH A Partner /Member 08/05/2010 01/01/2006 ROBINETT, PAUL J Partner /Member 08/05/2010 HERMANSON, RICHARD L Partner /Member 01/01/1980 ALMON, KEVIN Partner /Member 01/01/1980 08/05/2010 MACDONALD, JAMES Partner /Member 01/01/1980 08/05/2010 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 4 WESTERN SURETY CO 929381801 01/01/2006 Until Cancelled $12,000.00 12/01 /2005 3 TRAVELERS CAS a SURETY CO 081S103514123BCM 07/22/2001 Until Cancelled 01/01/2006 $12,000.0008/21 /2001 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 9 American GL0370326107 08/21/2010 08/21/2011 $1,000,000.0008 /18/2010 Zurich Ins Co ZURICH 8 AMERICAN INS GL0370326106 08/21/2008 08/21/2010 $1,000,000.00 08/24/2009 CO 7 AMERICAN GL03703261 08/21/2004 08/21/2008 $1,000,000.0008 /20/2007 ZURICH INS CO 04 6 AMERICAN ZURICH INS CO GL03703261 03 08/21/2004 08/21/2007 $1,000,000.00 08/18/2006 https://fortress.wa.gov/lni/bbip/Print.aspx 05/17/2011 A AC ACH ACT AD ADD'L AFF AFG AHU ALU M AMP /AMPS AP ARCH BC BDD BF BHP BLDG BOD BOP BOT BS BTU BTUH CAP CC CD CDWR CDWS CFM CHWR CHWS CLG COL CONC COND CONN CONT CONTR COORD COP CT CU CW DB DBA DDC DEFL DEG DG DIA DMPR DN DT DWG EXH EA EAT EC EER EF EFF EL ELEC /ELECT EP EMCS ENT EQUIP ESP EWT EXIST F FAC FD FDC FF FIC FIO FLA FLEX FLR FOB FOIC FOS FOT FP FPM FSD FT FUT FV G GA GALV GC GEN GPM GR GRD GWB HD HORIZ HP HR HSPF HT HWTG HWR HWS HX AMPS AIR CONDITIONING AIR CHANGES PER HOUR ACOUSTICAL TILE CEILING ACCESS DOOR ADDITIONAL ABOVE FINISHED FLOOR ABOVE FINISHED GRADE AIR HANDLING UNIT ALUMINUM AMPERAGE ACCESS PANEL ARCHITECT BEADED COLLAR BACK DRAFT DAMPER BELOW FLOOR BRAKE HORSEPOWER BUILDING BOTTOM OF DUCT BOTTOM OF PIPE BOTTOM BIRD SCREEN BRITISH THERMAL UNIT BRITISH THERMAL UNITS PER HOUR CAPACITY CONTROLS CONTRACTOR CEILING DIFFUSER /CONDENSATE DRAIN CONDENSER WATER RETURN CONDENSER WATER SUPPLY CUBIC FEET PER MINUTE CHILLED WATER RETURN CHILLED WATER SUPPLY CEILING COLUMN CONCRETE CONDENSATE CONNECT /CONNECTED /CONNECTION CONTINUOUS- / CONTINUATION CONTRACTOR COORDINATE COEFFICIENT OF PERFORMANCE COOLING TOWER CUBIC / CONDENSER UNIT DOMESTIC COLD WATER /CONDENSER WATER DUCTBOARD /DRY BULB DECIBEL DIRECT DIGITAL CONTROL DEFLECTION DEGREE/ DEGREES MODULAR DIFFUSER DIAMETER DAMPER DOWN MODULAR DIFFUSER DRAWING EXHAUST EACH ENTERING AIR TEMPERATURE EGGCRATE GRILLE /END CAP /ELEC CONTRACTOR ENERGY EFFICIENT RATING EXHAUST FAN EFFICIENCY ELEVATION ELECTRICAL /ELECTRIC END PLUG ENERGY MANAGEMENT CONTROL SYSTEM ENTERING EQUIPMENT EXTERNAL STATIC PRESSURE ENTERING WATER TEMPERATURE EXISTING FAHRENHEIT FIRE ALARM CONTRACTOR FIRE DAMPER FIRE DEPARTMENT CONNECTION FINISHED FLOOR FURNISHED AND INSTALLED BY CONTRACTOR FURNISHED AND INSTALLED BY OWNER FULL LOAD AMPS FLEXIBLE FLOOR FLAT ON BOTTOM FURNISHED BY OTHERS. INSTALLED BY FLAT ON SIDE FLAT ON TOP FIRE PROTECTION FEET PER MINUTE FIRE /SMOKE DAMPER FOOT /FEET FUTURE FACE VELOCITY GRILLE GAUGE /GALLON GALVANIZED GENERAL CONTRACTOR GENERAL GALLONS PER MINUTE GRILLE GRILLE /REGISTER /DIFFUSER GYPSUM WALL BOARD HEAD HORIZONTAL HORSEPOWER HOUR HEATING SEASONAL PERFORMANCE FACTOR HEIGHT HIGH WALL TRANSFER GRILLE HOT WATER RETURN HOT WATER SUPPLY -TEAT EXCHANGER ABBREVIATIONS HZ IBC IOW ID IE IMC IN IN WG I'PLV KW LAT LB/ BS LD /LIN DIFF LF /LIN FT LPG LVG LWA LWG LWR LWT MAX MAU MBH MCA MD MFR MISC MIN MT MTD MUW N/A NC NG /NGAS NIC NO NPW N -R OA /OSA OB OBD OD P PCF PD PH POC PRESS PSI PSIG QTY R RA RD /RND REF REG REQ RESID RF RG RL RPM RS S SA SAT SD S/D SEER SENS SG SL SM SPEC SO SOG SP SQ FT SR SS STRUC T TA TEMP TBD TG TOG TOD TOS TOT TSP TSTAT TYP UH UNO V VIAQC VD VEL VERT VFD VOL W WB WG W/ W/O W /SF WSEC CONTRACTOR I " FOR: F : echanical ctrical Plumbing as Piping y of Tukwila ION HERTZ INTERNATIONAL BUILDING CODE INDUSTRIAL COLD WATER INSIDE DIAMETER /DIMENSION INVERT ELEVATION INTERNATIONAL MECHANICAL CODE INCHES INCHES WATER GAUGE INTEGRATED PART LOAD VALUE KILOWATTS LEAVING AIR TEMPERATURE POUND /POUNDS LINEAR DIFFUSER LINEAL FOOT /FEET LIQUID PROPANE GAS LEAVING SOUND POWER LOW WALL GRILLE LOW WALL REGISTER LEAVING WATER TEMPERATURE MAXIMUM MAKE UP AIR UNIT 1000 BRITISH THERMAL UNITS MINIMUM CIRCUIT AAPACITY` MOTORIZED DAMPER MANUFACTURER MISCELLANEOUS MINIMUM /MINUTE MOUNT MOUNTED MAKE -UP WATER NOT APPLICABLE NORMALLY CLOSED /NOISE CRITERIA NATURAL GAS NOT IN CONTRACT NORMALLY OPEN /NUMBER NON- POTABLE WATER NON - RESIDENTIAL OUTSIDE AIR OPPOSED BLADE OPPOSED BLADE DAMPER OUTSIDE DIAMETER /DIMENSION PUMP POUNDS PER CUBIC FOOT PRESSURE DROP PHASE POINT OF CONNECTION PRESSURE POUNDS PER SQUARE INCH POUNDS PER SQUARE INCH GAUGE QUANITY RETURN GRILLE /RELOCATED /RETURN RETURN AIR ROUND REFERENCE REGISTER REQUIRED RESIDENTIAL RELIEF RETURN GRILLE REFRIGERANT LIQUID REVOLUTIONS PER MINUTE REFRIGERANT SUCTION SUPPLY SUPPLY AIR SATURATION SMOKE DETECTOR SLIP & DRIVE CONNECTION SEASONAL ENERGY EFFICIENCY RATING SENSIBLE SUPPLY GRILLE SOUND LINED SPIRALMATE /SHEETM SPECIFICATION SCREENED OPENING SLAB ON GRADE STATIC PRESSURE SQUARE FEET SIDE WALL REGISTER STAINLESS STEEL STRUCTURAL TRANSFER TRANSFER AIR TEMPERATURE /TEMPORARY TO BE DETERMINED TRANSFER GRILLE TOP OF CONCRETE /CURB TOP OF DUCT TOP OF STEEL /TOP, OF SLAB TOTAL TOTAL STATIC PRESSURE THERMOSTAT TYPICAL UNIT HEATER UNLESS NOTED OTHERWISE VOLT VENT. AND INDOOR AIR QUALITY CODE VOLUME DAMPER, VELOCITY VERTICAL VARIABLE FREQUENCY DRIVE VOLUME WALL /WALLS, WRAPPED DUCT WET BULB WATER GAUGE WITH WITHOUT WATTS PER SQUARE FOOT WASHINGTON STATE ENERGY CODE MECHANICAL LEGEND 10X10 IX RECTANGULAR SUPPLY AIR DUCT - 10X10 TURNING UP OR TOWARD 10X1;.` 10X10 10X10 L/1 10X 1p 10X10',, 1 $10X10 10o 100 6 10o 100 0 0 100 1 100 100 100 RECTANGULAR SUPPLY AIR DUCT - TURNING DOWN OR AWAY RECTANGULAR EXHAUST OR RETURN AIR DUCT - TURNING UP OR TOWARD RECTANGULAR EXHAUST OR RETURN AIR DUCT - TURNING DOWN OR AWAY ROUND DUCT - TURNING UP OR TOWARD ROUND DUCT - TURNING DOWN OR AWAY FLATOVAL DUCT - TURNING UP OR TOWARD FLATOVAL DUCT - TURNING DOWN OR AWAY DUCT OVERLAP BOOT TAP 45' TAP VOLUME DAMPER CHANGE OF ELEVATION RISE(R) DROP(D) TRANSITION TURNING VANES /SPLITTERS DUCT MOUNTED SMOKE DETECTOR BACK DRAFT DAMPER FLEXIBLE DUCT AIR FLOW DIRECTION FORCED AIR) R AIR FLOW DIRECTION SD A AIR) ) MOTOR OPERATED DAMPER FLEX CONNECTION' SMOKE DAMPER FIRE DAMPER COMBINATION FIRE SOUND TRAP ACCESS DOORS SMOKE DAMPER 6X6SL � ACOUSTICALLY LINED DUCT �- 16X16D6 DUCT BOARD FABRIC DUCT VAV BOX O 0 CD1 -100 80 SOUND LINED) CEILING SUPPLY AIR DIFFUSER (SHOWN WITH REDIRECTED AIR CORE) CEILING RETURN, TRANSFER OR EXHAUST AIR GRILLE SLOTTED DIFFUSER (PLAN VIEW) REVISION CLOUD & TRIANGLE ROUND DUCT SYMBOL FLATOVAL DUCT SYMBOL DEGREES SYMBOL POINT OF CONNECTION GRD TAG IDENTIFIER = TYPE -CFM SIZE THERMOSTAT /TEMPERATURE SENSOR HUMIDITY SENSOR SMOKE DETECTOR STATIC PRESSURE SENSOR EXISTING DUCTWORK DEMO DUCTWORK WALL- MOUNTED GRILLE 0 PIPE ELBOW UP CHWS CHWR RL RS NG LPG CDWS CDWR HWS HWR COND PIPE ELBOW DN DIRECTION OF FLOW DIRECTION OF SLOPE DOWN PLUG OR CAP GAS PRESSURE REDUCING ASSEMBLY SOLENOID VALVE PUMP CHILLED WATER SUPPLY CHILLED WATER RETURN REFRIGERANT LIQUID REFRIGERANT SUCTION NATURAL GAS LIQUID PROPANE GAS CONDENSER WATER SUPPLY CONDENSER WATER RETURN HEATING WATER SUPPLY HEATING WATER RETURN CONDENSATE MECHANICAL GENERAL NOTES 1. ALL WORK SHALL CONFORM TO ALL APPLICABLE CODES AND REGULATIONS, INCLUDING, BUT NOT LIMITED TO THE 2009 IBC, 2009 WSEC, & 2009 IMC. 2. DIMENSIONS ARE TO FACE OF STUD, CONCRETE, OR MASONRY UNLESS NOTED OTHERWISE. 3. DO NOT SCALE DRAWINGS. DIMENSIONS GOVERN. 4. VERIFY ALL EXISTING CONDITIONS, DIMENSIONS, DETAILS, ETC. NOTIFY ENGINEER OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH THE WORK. VISIONS No changes shall b ade to the scope of work without prior approval of Tukwila Building Ilion. NOTE: Revisions will require a new plan submittal and may include additional la review fees. 5. WHEN CONSTRUCTION DETAILS A R E NOT SHOWN OR FOR ANY PART OF THE WORK, DETAILS SHALL BE THE SAME R NOTED AS FOR OTHER SIMILAR WORK. IF ADDITIONAL QUESTIONS REMAIN, CONTACT THE ENGINEER PRIOR TO PROCEEDING. THE ' GENERAL 6. ALL STRUCTURAL OPENINGS AND PLATFORMS SHALL BE PROVIDED BY T GE E AL CO NTRACTOR UNLESS NOTED OTHERWISE. 7. DUCT SEALING AND CONSTRUCTION TO MEET SMACNA AND ENERGY CODE REQUIREMENTS. UNLESS OTHERWISE NOTED, LOW PRESSURE DUCTWORK (DOWNSTREAM OF VAV BOXES, CONSTANT VOLUME AC SYSTEMS, TOILET EXHAUSTS, ETC.) TO MEET 2» CONSTRUCTION STANDARDS WITH SEAL CLASS C. MEDIUM PRESSURE DUCTWORK (UPSTREAM OF VAV BOXES, HIGH VELOCITY EXHAUSTS, ETC.) TO MEET 4" CONSTRUCTION STANDARDS WITH SEAL CLASS A. DUCT RISERS IN SHAFTS WITH DAMPERED PENETRATIONS TO MEET 6" CONSTRUCTION STANDARDS WITH SEAL CLASS A. 8. ALL CEILING DIFFUSERS ARE 4 -WAY THROW UNLESS NOTED OTHERWISE. 9. ALL DUCT DIMENSIONS ARE CLEAR INSIDE DIMENSIONS AFTER LINING HAS BEEN INSTALLED. 10. OUTSIDE AIR INTAKES ON ALL AIR HANDLING UNITS SHALL BE 10 FEET AWAY FROM ANY FUEL BURNING EQUIPMENT AND 10 FEET AWAY FROM, OR 3 FEET BELOW ANY PLUMBING VENT OR EXHAUST OUTLET. 11. ALL AIR ECONIMIZERS SHALL BE CAPABLE OF THE FOLLOWING: -0 TO 100% OF THE DESIGN SUPPLY AIR - CONTROLLED BY A CONTROL SYSTEM DETERMINING IF THE OUTSIDE AIR CAN MEET PART OR ALL OF THE BUILDING COOLING LOADS. - INTEGRATED TO PROVIDE PARTIAL COOLING EVEN WHEN MECHANICAL COOLING 15 REQUIRED. 12. OUTSIDE AIR INTAKE, RELIEF, AND EXHAUST OPENINGS S H ALL BE EQUIP P ED W ITH MOTORIZED ( OR GRAVITY DAMPERS PER EXCEPTIONS IN 1412.4.1) WHICH CLOSE AUTOMATICALLY WHEN SYSTEM 15 OFF OR UPON POWER FAILURE. 7-DAY BEING SET FOR SEVEN (7) DIFFERENT DAY TYPES PER WEEK, THE CONTROL SYSTEM SHALL BE DAY PPQGRAMABLE, CAPABLE OF BEI G S () , AND CAPABLE OF A DEADBAND SETTING OF AT LEAST 5 DEGREES F ((1OT FOR RESIDENTIAL), BETWEEN THE HEATING AND COOLING SETPOI \ITS. AHU CONTROL SYSTEM SHALL INCLUDE A MICROPROCESSOR AND BE CAPABLE OF RESETTING SUPPLY AIR TEMPERATURES BY REPRESENTATIVE BUILDING LOADS. 14. RECORD DRAWINGS OF THE ACTUAL INSTALLATION SHALL BE PROVIDED TO THE BUILDING OWNER WITHIN 90 DAYS OF THE DATE OF SYSTEM ACCEPTANCE PER THE WASHINGTON STATE ENERGY CODE. AN OPERATING MANUAL AND MAINTENANCE MANUAL SHALL BE PROVIDED TO THE BUILDING OWNER. ALL HVAC SYSTEMS SHALL BE BALANCED AND A WRITTEN BALANCING REPORT SHALL BE PROVIDED TO THE OWNER. HVAC CONTROL SYSTEMS SHALL BE TESTED TO ENSURE THAT THEY OPERATE IN ACCORDANCE WITH SPECIFICATIONS AND APPROVED PLANS. A PRELIMINARY COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED PRIOR TO ISSUANCE OF A FINAL CERTIFICATE OF OCCUPANCY. A COMPLETE FINAL COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PROVIDED TO THE OWNER. COMMISSIONING, SYSTEM BALANCING, RECORD DRAWINGS AS REQUIRED PER THE WASHINGTON STATE ENERGY CODE, 15. MECHANICAL SYSTEMS SHALL COMPLY _ WITH SEISMIC RESTRAINT REQUIREMENTS OF THE BUILDING CODE, SMACNA AND ASCE 7. ALL LIFE SAFETY HAZARDOUS MATERIAL RELATED SYSTEMS SHALL BE DEEMED AN I =1.5 FOR RESTRAINT METHODS OR AS NOTED FOR INSTALLATION R AND EXCEPTIONS BASED ON SIZING, THE DRAWINGS. REFER TO THE ABOVE NOTED CODES OR , WEIGHTS AND MOUNTING HEIGHTS. SHE M0.00 M2.01 NO. SHEET TI E LEGEND, ABBREVIATIONS, PARTIAL FLOOR PLANS L ENERAL NOTES, & SHEET INDEX -- HVAC HVAC APN NUMBER 000580 -0024 LEGAL DESCRIPTION DER HENRY -D C #46 POR OF HENRY MEADER DONATION NO 46 IN SW 1/4 OF SEC 24 -23 -04 LY E OF ELY LN OF STATE HWY NO 181 5M (SR KNOWN AS WEST VALLEY HWY ( 181) OF WLY LN OF PUGET SOUND POWER & LIGHT CO R/W SEA -TAC PSE RR S OF 5 LN OF RD ESMT KNOWN AS S 158TH ST & ALSO KNOWN AS LONGACRES WAY & N OF A LN 446.38 FT S & PLL WHEN MEAS AT R A TO SD 5 LN OF S 158TH ST PER CITY OF TUKWILA BOUNARY LINE ADJ NO 88 -4 -BLA RECORDING NO 88093011`16 - -- LESS 6.50 FT LY SLY & PLL .S AT R/A TO 5 LINE OF SOUTH 158TH ST ■ Hermanson Hermanson Company LLP 1221 2nd Avenue North Kent, Washington 98032 Tel: (206) 575 -9700 Fax: (206) 575 -9800 .hermanson.com Co or Reg #: HERMACLOO5BJ EMBASSY SUITES 15920 W VALLEY HWY TUKIILA WA 98188 EQUIPMENT RE UIRED BY SMACNA SEISMIC RESTRAINT MANUAL, SEISMIC HAZARD B. 16. PROVIDE EARTHQUAKE RESTRAINTS FOR HVAC AS REQUIRED FOR CEILING SYSTEM ETC. SHALL NOT BE HUNG OFF HVAC EQUIPMENT OR HVAC EQUIPMENT SUPPORTS. g 17. PROVIDE FIRE AND COMBINATION FIRE /SMOKE DAMPERS WHERE SHOWN ON PLANS AND WHERE REQUIRED PER CODE. 18. ALL PIPING PENETRATIONS THROUG-I RATED ASSEMBLIES SHALL BE SEALED WITH AN UL APPROVED FIRE CAULKING. 19, SMOKE DETECTORS PROVIDING AUTOMATIC SHUTDOWN SHALL BE PROVIDED FOR HVAC EQUIPMENT DELIVERING IN EXCESS OF 2000 CFM [INCLUDING MULTIPLE ` UNITS DUCTED INTO COMMON DISTRIBUTION OR RETURN, WITH AN AGGREGATE SUPPLY GREATER THAN 2000 CFM OR EACH STORY OF RETURN SYSTEMS OVER 15,000 CFM IN A MULTI -STORY INSTALLATION, PER CODE. SMOKE DETECTORS SHALL BE FURNISHED AND ' NSTALLED BY ELECTRICAL CONTRACTOR UNLESS NOTED OTHERWISE. POWER- WIRING AND INTERLOCK TO FIRE ALARM SYSTEM BY ELECTRICAL CONTRACTOR AS APPLICABLE. 20. ACCESS PANELS SHALL BE PROVIDED BY MECHANICAL CONTRACTOR AND INSTALLED BY GENERAL CONTRACTOR. 21. ALL MOTOR STARTERS NOT SHOWN IN EQUIPMENT SCHEDULES SHALL BE FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR. 22. FOR ALL "SEALED AIR TIGHT" SHAFTS OR ROOMS, THE FOLLOWING SHALL OCCUR: ALL VERTICAL JOINTS INSIDE THE SHAFT SHALL BE PROVIDED WITH A CONTINUOUS SEAL FOR THE LENGTH OF THE JOINT, INCLUDING THE SHAFT CORNERS (BY GC) -TOP AND BOTTOM WALL TRACKS S-IOULD BE CAULKED ALONG THEIR ENTIRE LENGTH (BY GC) -ANY FLOOR DECKING PERPENDICULAR TO THE SHAFT SHALL BE CAULKED (BY GC). FILLING WITH ROCK WOOL IS NOT ACCEPTABLE -ANY PENETRATIONS OF THE SHAFT CONSTRUCTION (DUCTWORK, CONDUIT, PIPING, ...) SHALL BE SEALED ON BOTH SIDES OF THE PENETRATION. -USE SECTION 905 OF THE 2009 IBC FOR MAXIMUM ALLOWABLE LEAKAGE AREA, FOLLOWING THE GUIDELINES FOR TIGHT STAIR SHAFT CONSTRUCTION. -ALL DOORS SHALL BE PROVIDED WITH TIGHT FITTING GASKETS AND OPEN AGAINST THE DIRECTION OF ROOM SHAFT PRESSURE. r ROOM/ SHAFT MAXIMUM LENGTH OF FLEXIBLE DUCT SHALL BE 12 FEET. REFER TO INSTALLATION DETAILS FOR SUPPORT REQUIREMENTS. FLEXIBLE DUCT FLAME SPREAD RATING SHALL BE '< 25 AND SMOKE DEVELOPED RATING SHALL BE < 50. USE FLEXIDUCT MODEL G -KM FOR LOW AND MEDIUM PRESSURE APPLICATIONS OR APPROVED EQUAL. INSULATE DUCT PER NOTE 11 ABOVE. 24. LOCATION AND DETAILS OF EQUIPMENT, DUCT ROUTING, AND CONNECTIONS ARE APPROXIMATE. COORDINATE FINAL LOCATIONS WITH OTHER TRADES. INSTALL IN ACCORDANCE WITH APPROVED SUBMITTALS AND DETAIL DRAWINGS WHEN APPLICABLE. 25. FOR RESIDENTIAL INSULATION ON DUCTWORK AND PIPING SEE ENERGY CODE CHAPTER 5 AND TABLES 5 -11 AND 5 -12. 26. ELECTRICAL SUBMETERING OF SYSTEMS AS REQUIRED BY ENERGY CODE CHAPTER 12 IS BY ELECTRICAL CONTRACTOR. DUCT INSULATION SUPPLY, RETURN OUTSIDE AIR INTAKE SUPPLY, RETURN, OUTSIDE AIR INTAKE SUPPLY WITH <55' OR >105' AIR TEMPERATURE R -VA LIE) NOT WITHIN CONDITIONED SPACE: ON EXTERIOR OF BUILDING, 0\I ROOF, IN ATTIC, IN ENCLOSED CEILING SPACE, IN WALLS, IN GARAGE, IN CRAWL SPACES WITHIN CONDITIONED SPACE NOT WITHIN CONDITIONED SPACE: IN CONCRETE, IN GROUND WITHIN CONDITIONED SPACE N -R INSULATION R -VALU E R -7 VARIES R -5.3 R -3.3 LAST UPDATED: 07/21 / 10 RESID. INSULATION R -VALUE R -8 R -8 R -5.0 NOT REQ. 1. REFER TO ENERGY CODE SECTION 1414.2 FOR FURTHER REQUIREMENTS 2. REQUIREMENTS APPLY TO HEATED AND MECHANICALLY COOLED DUCT SYSTEMS AS NOTED. INSULATED COOLED DUCTS REQUIRED A VAPOR RETARDER (PERM < 0.51 AND SEALED JOINTS. 3. WEATHERPROOF BARRIER REQUIRED AROUND DUCTWORK TO MAINTAIN WATER TIGHTNESS. 4. INSULATE OUTSIDE AIR DUCTS TO BUILDING ENVELOPE LEVEL PER ENERGY CODE CHAPTER 13 UNTIL CONNECTED TO EQUIPMENT SERVED OR TO THE CODE REQUIRED SHUTOFF DAMPER (THEN R -7 FOR REST OF WSTALLATION ). 5. R -7 CAN BE USED IN LIEU OF BUILDING ENVELOPE INSULATION LEVEL IF: DEDICATED OUTSIDE AIR SYSTEM AND LESS THAN 2,800 CFM. PIPE NSULATION SERVICE HWSCR HWS &R CH CHWS .CD WS&R FLUID TEMP T 41 -200 105 -140 40 -45 <40 40 -45 CONDENSER WATER NCHES) INSULATION CONDUCTIVITY CONDUCTIVITY RANGE 0.25 -0.29 0.24 -0.28 0.23.0.27 0.23 -0.27 0.23 -0.27 FOR NON -ECONO 125 00 75 75 75 ZER SYSTEMS SST UPDATED: 07/ NOMINAL RUN-OUTS UP TO 2 0.5 0.5 0.5 0.5 PIPE DIAMETER 5 5 :5 1.5 1 TION IS NOT REQUIRED) 5 REMARKS 1,2,3 1,2,4,5 1,2 1,2 SITE MAP Pe Plan revi p I Nod to Pr I of n nd u' n the violation of oved Field Copy aty Of BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE APPROVED RECEIVED MAY 1 1 2011 ENTER ISSUE FOR PERMIT Revisions 05/04/11 CS ISSUE FOR PERMIT No. Data By Description Design, Drown Des i gn Team s RR Checked DN Scab AS NOTED Drawing Number C- 0307 -1348 Project Number 14- 1-1348 Issue Date 05/04/ EGEND, ABBREVIATIONS, GENERAL NOTES, & SHEET INDEX HVAC M0.00 %` 22X22 48X30 SA FROM LOBBY / / / / / //i CD /.' iI %i,r: % // 12X12 COMBUSON AIR UP TVROOF CAP 22X22 (TYP 3) (EXISTING) i 770 CFM' ,v 4e# /;% BOILER OILER 22X22 (TYP 2) 770 CFM 126 /----- - \o� *1/29,„,/22o ///// % %, 22X22 (TYP 2) \\ A 1 EF -11 48X36 (4000 CFM) PARTIAL FLOOR DEMO PLAN LEVEL 1 - HVAC t REVIEWED FOR CODE COMPLIANCE " t APPROVED \� 880 CFM 41k X6 (—YP 2) 75 CFM 48X30 SA FROM LOBBY 22X22 JCAP CAPS, 1\60 AL CAS POOL BOILER `L > SPA BOILER OUTLINE OF SKYLIGHT ABOVE SCALE: 1/8" = 1' -0 N DEMO NOTES: 01 DEMO & DISPOSE EF -11. 02 DISCONNECT AND ABANDON IN PLACE SF -4 & ECD -10. DEMO ANY DUCT WORK FROM THIS SYSTEM AS NEEDED FOR NEW CONSTRUCTION. MAY 16 LJdi City of Tukwila BUILDIN( r�i�►lS�nnw N ® DH -1 48X36 PARTIAL FLOOR PLAN LEVEL 1- HVAC SCALE: 1/8" = r -o° SCALE: 1/8" = DESIGN NOTES: DESIGN NOTES: OA FURNISH & INSTALL DEHUMIDIFICATION UNIT & ELECTRIC DUCT HEATER. TEMPERATURE & HUMIDITY SENSORS INCLUDED. ® USE ALUMINUM DUCT IN POOL /SPA AREA. © DRAIN DEHUMIDIFIER TO FLOOR DRAIN IN BOILER ROOM. © EXHAUST TERMINATES AT EXISTING LOUVER DEHUMIDIFIER SCHEDULE LAST UPDATED: 04/19/11 UNIT TAG SERVES BASIS OF DESIGN TYPE CFM ESP MOISTURE REMOVAL SUPPLY FAN ELECTRICAL WEIGHT LBS REMARKS MCA MFS V /PH DH -1 POOL/SPA AREAS APPLIED ENERGY AHD -060 HORIZONTAL 1600 0.5 23 LBS /HR 1 HP 14.0 20 460/3 360 1,2,3 1 DISCONNECT BY ELECTRICAL 2 PROVIDE WITH EPDXY COATED AIR COILS AND BLOWER ASSEMBLY, R -410A REFRIG, HORIZONTAL SUPPLY & RETURN, THERMOSTAT AND HUMIDISTAT 3 3/4" CONDENSATE - ROUTE TO NEAREST DRAIN ELECTRIC DUCT HEATER SCHEDULE LAST UPDATED: 04/19/11 UNIT TAG LOCATION SERVES BASIS OF DESIGN KW TOTAL CFM DUCT ELECTRICAL WEIGHT LBS REMARKS WIDTH IN HEIGHT IN FLA V /PH EDH -1 DEHUMIDIFACTION DH -1 WARREN CBK 15.0 1,600 18.0 18.0 - 460/3 75 1,2,3 1 PROVIDE AIR PRESSURE SWITCH, MANUAL AND AUTO LIMIT C ONTROLS, MAGNETIC CONTACTORS, 24V CONTROLS TRANSFORMER AND ROOM T -STAT 2 DISCONNECT SWITCH BY ELECTRICAL 3 STAINLESS STEEL ELEMENT CONNECTIONS FAN SCHEDULE LAST UPDATED: 04/19/11 UNIT BASIS OF ESP MOTOR ELECTRICAL WEIGHT TAG LOCATION SERVES DESIGN TYPE CFM IN WG BHP W V /PH DBA LBS REMARKS EF -1 POOL AREA PLENUM POOL / SPA CFM AXC 355A INLINE 1,030 0.30 NA 334.0 120V/1 57 26 1,2 1 ELECTRICAL DISCONNECT AND MOTOR STARTER (AS REQUIRED) BY ELECTRICAL CONTRACTOR 2 FAN TO OPERATE CONTINUOUSLY M11-.013 SCALE: 8"1' RECEIVED MAY 112011 PERMIT CENTER 1 ' 3 5' 10' 15' 25' i 2' 4' ISSUE FOR PERMIT Hermanson Hermanson Company LLP 1221 2nd Avenue North Kent, Washington 98032 Tel: (206) 575 -9700 Fax: (206) 575 -9800 www.hermanson.com Contractor Reg 11: HERMACLOO5BJ EMBASSY SUITES 15920 W VALLEY HWY TUKWILA, WA 98188 Revisions 05/04/11 CS ISSUE FOR PERMIT No. Date By Description Design Design Team CS Drawn RR Checked DN Scale AS NOTED Drawing Number C- 0307 -1348 Project Number 14 -1 -1348 Issue Date 05/04/11 PARTIAL FLOOR PLANS LEVEL 1 - HVAC M2.01