Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M11-080 - TACO TIME
TACO TIME 15037 TUKWILA INTERNATIONAL BL Mi 1 -080 City olPTukwila 0 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: htto: / /www.TukwilaWA.gov MECHANICAL PERMIT Parcel No.: 0041000493 Address: 15037 TUKWILA INTERNATIONAL BL TUKW Project Name: TACO TIME Permit Number: M11 -080 Issue Date: 11/15/2011 Permit Expires On: 05/13/2012 Owner: Name: Address: Contact Person: Name: Address: Email: HAWLEY ENTERPRISES INC PO BOX 1002 , ENUMCLAW WA 98022 HOWARD G KIMURA HG KIMURA ARCHITECT , PO BOX 59415 98058 H G KIMURA@ C O MCAST. NET Contractor: Name: EMERALD AIRE INC. Address: 22043 68TH AVENUE SOUTH , KENT, WA 98032 Contractor License No: EMERAAI055BL Phone: 425 - 271 -1875 Phone: 206 872 -5665 Expiration Date: 04/01/2013 DESCRIPTION OF WORK: HVAC FOR NEW RESTAURANT. (2) NEW ROOFTOP UNITS (GAS HEATING & ELECTRIC COOLING), (1) TYPE I HOOD & EXHAUST, (1) TYPE II HOOD & EXHAUST, (1) MAKEUP AIR UNIT Value of Mechanical: $75,000.00 Type of Fire Protection: UNKNOWN Electrical Service Provided by: Permit Center Authorized Signature: Fees Collected: $1,053.31 International Mechanical Code Edition: 2009 Date: I hereby certify that I have read and 4xami d this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complie with, Nether specified herein or not. The granting of this permit does not pre construction or the performance of work. back of this permit. Signature: Print Name: to give authority to violate or cancel the provisions of any other state or local laws regulating I am authorized to sign and obtain this mechanical permit and agree to the conditions on the vin 12,-> v c, -f r` \'\,(1 Date: ► 115l 1 1 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -4/10 M11-080 Printed: 11 -15 -2011 • PERMIT CONDITIONS Permit No. M11-080 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: Readily accessible access to roof mounted equipment is required. 5: All construction shall be done in conformance with the approved plans and the requirementsiof the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Manufacturers installation instructions shall be available on the job site at the time of inspection. 7: All plumbing and gas piping work shall be inspected and approved under a separate permit'issued by the City of Tukwila Building Department (206- 431 - 3670). 8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 10: ** *FIRE DEPARTMENT CONDITIONS * ** 11: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 12: A Type 1 hood shall be installed at or above all commercial cooking appliances and domestic cooking appliances used for commercial purposes that produce grease vapors. Each required commercial kitchen exhaust hood and duct system required by section 610 of the International Fire Code to have a Type 1 hood shall be protected with an approved automatic fire - extinguishing system installed in accordance with this code. (IFC 610.2, IFC 904.2.1 and IFC 904.11) Automatic fire- extinguishing systems shall comply with UL 300 or other equivalent standards and shall be installed in accordance with the requirements of the listing. (NFPA 96, 10.2.3) 13: Type I hood systems shall be designed and installed to automatically activate the exhaust fan whenever cooking operations occur. The activation of the exhaust fan shall occur through an interlock with the cooking appliances, by means of heat sensors or by means of other approved methods. (IMC 507.2.1.1) 14: All new automatic fire - extinguishing systems and all modifications to existing automatic fire - extinguishing systems shall have fire department review and approval of drawings prior to installation or modification. 15: Portable fire extinguishers shall be provided within a 30 -foot (9144 mm) travel distance of commercial -type cooking equipment. Cooking equipment involving vegetable or animal oils and fats shall be protected by a Class K rated portable extinguisher. (IFC 904.11.5) 16: U.L. central station supervision is required. (City Ordinance #2050) 17: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 18: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spacesiwithin buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air- moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) doc: IMC -4/10 • M11-080 Printed: 11 -15 -2011 19: Remote indicator lights are re lik d on all above ceiling smoke detectors. (Cill)rdinance #2051) 20: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) 21: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 22: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 23: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 24: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 25: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 26: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 27: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: IMC -4/10 M11-080 Printed: 11 -15 -2011 J CITF Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www,ci.tukwila.wa.us Building Permit No. Mechanical Permit No. VL k l - O t Plumbing/Gas Permit No. Pry 11-- 0 PL Public Works Permit No. Project No. (For office use onp) . Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print** 1 SITE LOCATION' dts4ie- p — o �.” King Co Assessor's Tax No.: Site Address: /j 3 7 TU/CWI Lit iN 1 ed/An A/R 1. ,8N/0 Suite Number: Teams me: 7 i4't.v 11111.* B Property Owners Name: PA1 -bwzA f}>rtii Y PO475ps,.e,Pr Mailing Address: 2 (4 / L Se' 'i 3 2•.. 1 Jr e'su -, 1 Ja- — o4F94 — 049D Floor. .....Yes .. No City 1444- T ', 2L Smote Zip CONTACT:PERSON —.who do we contact when your penait is ready to be issued Name: Auroral( 6- J4»,o s7 /ft Xlnw/n A124 4 Day Telephone: Mailing Address: E-Mail Address: Pp ok 4F/S-- Red, Ptah, Wkt /War 4z.r 27/- 1r7.r i11�k.1 es nr t GowibosJl: iu1 City Fax Number. // state zip .2cr' _271-71,P? - GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg4) for Plumbing and Gas Piping (pg 5)) Company Name: 6 Mailing Address: City Contact Person: Day Telephone: E-Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Slate Zip ARCHITECT OF RECORD — All plans must be stamped by Architect of Record Company Name: A'i.s a AS G0/4"TrreT —va 1•n/ Mailing Address: City Contact Person: Day Telephone: E-Mail Address: Fax Number: State Zip ENGINEER OF RECORD — All plans must be stamped by Engineer of Record 1 Company Name: lie ellei - R1vn.lAJ e?e 404 6— 6-2e v crrz t►_ €e7-44 7 =7'°- Mailing Address: City Day Telephone: .'/2J 'tfl - 4'f .s, Fax Number Contact Person: E-Mail Address: II/ / //G 1" e 414e 1(..e- c /ftva -C r4..?- 9e004/ 9:Mppticm6omuamrAnyptinuons On t%no12010 A{plicntian17-20t0 -Flom, Appliahon.doe Revised: 7 -2010 bb State Zip Page 1 of 6 IMECHANICAL PERMIT INFORMATION — 206 -431 -3670 MECHANICAL CONTRACTOR INFORMATION Company Name: Mailing Address: city Contact Person: Day Telephone: E-Mail Address: Pax Number: Contractor Registration Number. Expiration Date: State Zip Valuation of Mechanical work (contractor's bid price): $_ r%J 000 ??�,� Scope of Work (please provide detailed infotmatiofi / !x l Vui4 COft S 1 �}'r, ! - v, CooLJ 146 } p5NPe Z iJooi fi wALs -Tia 2 kicogikixescrao Art, ofirr tJsc: Residential: New .... ❑ Replacement .... ❑ Commercial: New .... Replacement .... ❑ fuel Tyne: Electric .....❑ Gas ....O Other. Indicate type of mechanical work being installed and the quantity below: Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Funtacc<100K BTU Air Handling Unit >10,000 CFM Fire Damper - 0-3 HP /I00,000 BTU Futnace>100K BTU Evaporator Cooler Diffuser is-- 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Z Thermostat Z. 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/GasStove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ 1•IP/I,750.000 BTU Repair or Addition to Hcat /Rcfrig/Cooling System Incinerator - Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM Incinerator — Cotntn/1nd tt:tAppthai4n,Ah'u ns- Apptiratinm on U ne1201OAry iaaUw, 7 -into- Axmit Appliratiw,.doc Ravncd: 7-2010 hh Page 4 of 6 PERMIT APPLICATION NOTES = Applicable to all permits in this- application Valve of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no pennit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Pcmlit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 1053.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). 1 HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER O1j AbRIZED A Signature: Print Name: Mailing' Address: ?AI 33 o .AuQpie Vag, 117h4we y rDate Application Accepted: Date:// 41./ l j Day Telephone: 441 27.G I G SZ A€12h,'2. l trig •ErtrI-237 City State Zip Date Application Expires: Staff Initials: H:1ApplimtociW - Applialim& On lino12010 AivliclionA7 -2010 -rhnit Application-duo Revised: 7 -2010 bU Page 6 of 6 SET RECEIPT Copy Reprinted on 11 -15 -2011 at 15:42:19 11/15/2011 RECEIPT NO: R11 -02491 Initials: WER Payment Date: 11/15/2011 User ID: 1655 Total Payment: 935.05 Payee: EMERALD AIRE INC. SET ID: 1115 SET NAME: Temporary Set SET TRANSACTIONS: Set Member EL11 -1033 M11 -080 TOTAL: Amount 92.40 842.65 842.65 TRANSACTION LIST: Type Method Description Amount Payment Check 1583 935.05 TOTAL: 935.05 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.0 MECHANICAL - NONRES 000.322.102.00.0 92.40 842.65 TOTAL: 935.05 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov RECEIPT Parcel No.: 0041000493 Permit Number: M11 -080 Address: 15037 TUKWILA INTERNATIONAL BL TUKW Status: PENDING Suite No: Applied Date: 06/16/2011 Applicant: TACO TIME Issue Date: Receipt No.: R11 -01229 Payment Amount: $210.66 Initials: WER Payment Date: 06/16/2011 02:27 PM User ID: 1655 Balance: $842.65 Payee: TACO TIME TRANSACTION LIST: Type Method Descriptio Amount Payment Check 601478 210.66 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 210.66 Total: $210.66 doc: Receiot -06 Printed: 06 -16 -2011 INSPECTION RECORD Retain a copy with permit ' INSPECITION NO. PERMIT NO. CITY OF TUKWILA' BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -367 Permit Inspection Request Line (206) 431 -2451 ill II- 080 Project: Type offInspection: ' Address: 6 Date Called: O. a.7. Special Instructions: • ,i4„-,p,;--,i4„-,p,;--/ 4 14,40 /09k/7-7A' 4 / Date Wanted:. a.m_ Requester: Phone No: • tilAp.s., . proved per applicable codes. Corrections required prior to approval. • COMMENTS: k,). ' . t0 .Y,N4fi 4P %f r Ii.e.44•/ *lc, // r'. ,i4„-,p,;--,i4„-,p,;--/ 4 14,40 /09k/7-7A' 4 / f • • Inspectoft Date: �" -z /� SPECTION FEE REQU - ED. Prio o next inspection. fee must be id at 6300 Southcenter Blv Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit /1_a'o .INSPECTION NO. PERMIT NO. ,�,( CITY OF BUILDIN ,:DIVISION �'_\ 63Q0 Southcenter Blvd., #100, Tukwila. WA 98188 ' (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project : -. �--{ Type f Inspec on: 04 j AA e Address: _ : t) ,�- Date Iled: /� s,I - (- 0 ,, . ,, Speaal Instructions: ialY Ef 44 e U 0 ..7-7/.e /-143 d I Date Wantec :. r (�"t� �a.m , p.m. Requester: Phone No: Approved per applicable codes. ElCorrections required prior to approval. / -3 COMMENTS: • Vic.4 Fie 3 (^.V J'' r\ A P gee. or M e,.,>tt . [ I &J A'{ 4f�T'.� . i.ti +-I- - _ #10 r Al AJ er— /�4. -v.6__ gr. # 1 "" J f'dI Spec -f'4 -? </U' c4. .6. in t ;to6 -,Y /hi . ..c,u.640..c. .1 e.,4 Imo' r:' its okkstk. LN P I N FEE , RE . S ECT 0 E E REQUIRED. rior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit in►t -o8() INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 it (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: Type of Inspecti n: 1'5 3-7 -VT- Date Called: 'Special Instructions: Date Wanted: : /Z p q / m : a: Requester: Phone No: 121Approved per applicable codes. E Corrections required prior to approval. COMMENTS: CD✓.v./sc° cY App ro/,9 ?v4 ►(e7rni Fes.+ I• Date: y4_?.- REI = • ECTION FEE REQUIRED .'rior to i 6xt inspection, fee must be id at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. • • • • INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. • CITY OF TUKWILA BUILDING DIVISION •6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 :Permit Inspection Request Line (206) 431 -2451 ProjeE' ' -4..--.1 - I '- (, SAL... -. Type of Inspection: (�DJ (�{-t �,i--#0 (14A1C(14 Address: t 0.3'i� Date Called: Speci�Instructions: - . Date Wanted:. -- am: 2 -30 k( p.m. Requester: Phone No. 7,0(0-2q2.--e(„E( Approved per applicable codes. orrections required prior to approval. COMMENTS: .i.-L_7 AA_ t -e_ ms's 4.: , fz,,� ,S1 r# - rrs ' 6 J it-L. bYC.15 'e is ._.4 Q1.' elst_ otc- ,-, iIns ector: Dater 6 'II REINSPECTION FEE REQUIRE'Prior to next inspection. fee must be ipaid.at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION tt 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 1)111 - d O Project: 7A Ov 7 »i € Type of Inspection: gc ?/6 t/ • V Address: /503- 'T-:-.L 3 Date Called: Special Instructions: Date Wanted:. (gym: Requester: Phone No: a0 4 - Goi✓ 22.6c ElApproved per applicable codes. D Corrections required prior to approval. COMMENTS: 4. 6/< f j _TA /67/1. i47 /y1/ S ?i+°A I- nspecto EIINSPECTION FEE REQUIRED. Priyf to next inspection, fee must be • Al at 6300 Southcenter lvd., Suit 100. Call to schedule reinspection. .alb ',A A '•44... Date: /1 -21- 1/ INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit ). { - oYO PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT ver Park East, Tukwila, Wa. 98188 206 -575 -4407 Project: Sprinklers: f,- Fire Alarm: Type of Inspection: , / Address: 15 0 3.7 Suite #: 7 . ; Contact Person! Special Instructions: Occupancy Type: Phone No.: Approved per applicable codes. cti Corrections required prior to approval. COMMENTS: Sprinklers: f,- Fire Alarm: tri Hood & Duct: Monitor: 47' i" ... Pre -Fire: Permits:- Occupancy Type: 1+ - i-- ow .. r- r.) 0 2, L j TO It. '`r-`) q C: 11 ( 'ia.CiL. 1 t �t� HiAC- O K 1 (4 T' i Al , i..� i...w .. • 1• 1� • • .e . J r .,.,1 - i ,' _ 3 d•�, �JS J p{ Pb: ?tie ci 1:2).r .),_../., \" k6 -,71 ?,..., .1^_ f•'_.4 w Needs Shift Inspection: ,- Sprinklers: f,- Fire Alarm: tri Hood & Duct: Monitor: 47' i" ... Pre -Fire: Permits:- Occupancy Type: Inspector: ., `.. �, ' , .. Date: r "�, / ( Hrs.: ;. . $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. CaII to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word /Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 MAYES TESTING ENGINEERS, INC. r _•: jai.. January 19, 2012 City of Tukwila Building Department 6200 South Center Blvd Tukwila, WA 98188 -8188 Attention: Building Official Re: Taco Time 15037 Tukwila International Boulevard Tukwila, WA Project No. L11431 REVISED 10:36 am, Jan 19, 2012 Final Letter Permit No. D11 -172 Ii— o 20225o3darVafeyRoad Stie110 Ly rmood, WA 980E6 ph 4257429360 at425.74S1737 Ta arsafoe 100293TammaWay Stir: E2 Taaarrrd WA 98499 ph 253584.3720 fat2535843707 PonlandalBoe 7911 nE331daM Sub 190 PatIsr0 CR97211 015=81.7515 fac503281.7579 This is to inform you that registered special inspections have been completed for this project as per our reports, copies of which have been sent to you. Special inspection was provided for: • Reinforced Concrete • Proprietary Anchors • Structural Steel Erection • Stainless Steel Duct Welding (Fire Suppression Hood) To the best of our knowledge, all work inspected was either performed in accordance with, or corrected to conform to, the city approved drawings, or engineer approved changes. We trust this provides you with the information that you require. Should you have any questions please call us at 425/742 -9360. Sincerely, Mayes Testing Engineers, Inc. Timothy G. Beckerle, P.E. Branch Manager 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Mechanical Summary MECH -SUM 2009 Washington State Energy Code Compliance Forms tor Nonresidential and Multifamily Residential 'If Project Info Project Address Taco Time Date 6/15/20111 15037 Tukwila International Blvd For Building Dept. Use 1 t �/ Tukwila, WA FILECOPY Applicant Name: Applicant Address: Applicant Phone: Project Description Briefly describe mechanical system type and features. ❑ Includes Plans i 2 Rooftop Gas Packs, Kitchen exhaust and Makeup Air System Include documentation requiring compliance with commissioning requirements, Section 1416. Compliance Option 0 Simple System 0 Complex System 0 Systems Analysis (See Decision Flowchart (over) for qualifications. Use separate MECH -SUM for simple & complex Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. Cooling Equipment Schedule Equip. ID Equip Type Brand Name' Model No.' Capacity2 Btu/h OSA CFM or Econo? SEER or EER IPLV3 Econmizer Option or Exception° Heat Recovery Y/N See Sheet M01 Heating Equipment Schedule Equip. ID Equip Type Brand Name' Model No.' Capacity2 Btu/h OSA cfm or Econo? Input Btuh Output Btuh Efficiency' Heat Recovery Y/N See Sheet 1(01 Fan Equipment Schedule Equip. ID Equip Type Brand Name' Model No.' CFM SP' HP/BHP Flow Controls Location of Service See Sheet M01 'REVIFWFn F CODE COIJPLIANCE i - availiaPROMED accord' g to Table 14 -1A through 14 -1G. 3 If required. ° COP, HSPF, Combustion Efficiency, or AFUE, as applicable. 5 Flow control types: variable air v me(VAV), constant volume (CV), or variable speed (VS). 6 Exception number from Section 1433. SEP 13 2011 City of Tukwila BUILDING DIVISION t1ttQ�o RECEIVED JUN 16 2011 PPRMITC NThR 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Mechanical - Complex Systems Checklist MECH =COMP 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised August 2010 Project Address Taco Time Date 6/15/2011 The following additional information is necessary to check a mechanical permit application for a complex mechanical system for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Use the checklist as a reference for notes added to the mechanical drawings (see the MECH -CHK checklist for additional requirements). This information must be on the plans since this is the official record of the permit. Having this information in separate specifications alone is NOT an acceptable alternative. For Building Department Use Applicability (yes, no, na) Code Section Component Information Required Location on Plans Building Department Notes ADDITIONAL CHECKLIST ITEMS FOR COMPLEX SYSTEMS ONLY N.A. 1431.1 Field assem. sys. Provide calculations for total onsite energy input/output to equip. Yea 1431.2 System Sizing Indicate equipment & system sizing complies with 1431.2 N.A. 1432.1 Setback & shut -off Indicate separate systems or show isolation devices on plans N.A. 1432.2.1 Air system reset Indicate automatic temperature reset & operation sequence N.A. 1432.2.2 Hydr. Sys. reset Indicate automatic temperature reset & operation sequence N.A. 1432.3.1 Hydr. Var. Flow Indicate variable flow method for all applicable systems N.A. 1432.3.X Hydronic Isolation Indicate method of isolation for all applicable systems N.A. 1432.4 DDC Capabilities Indicate control capabilities induding demand response setpoind adj. N.A. 1432.4 DDC data mgmt Indicate metering and trending capabilities. N.A. 1432.5 Pressure Reset Indicate static pressure reset for VAV systems Yes 1433 Air Economizer Indicate economizer on equipment schedule or provide calculations to justify exemption. Demonstrate higher efficiency equipment if required. N.A. 1433 Water Economizer Indicate water economizer and provide calculations showing compliance with 1413 if 1433 Exception 31s utilized N.A. 1434 Separate air sys. Indicate special requirement zones and Indicate systems N.A. 1435 Simul. htg. & clg. Indicate method of prohibiting simultaneous heating and cooling, or state excpetion and show supporting calculations N.A. 1436 Heat recovery Indicate heat recovery of all applicable systems on plans; complete and attach heat recovery calculations Yea 1437 Elec. motor effic. MECH -MOT or Equip. Schedule with hp. rpm, efficiency N.A. 1438 Variable speed drives Indicate VS control or equivalent on schedules for all applicable equip. N.A. 1438.1 Heat Rejection Indicate heat rejection equipment types and fan types N.A. 1438.2 Hot Gas Bypass Indicate cooling equipment staging and capacity modulation abilities N.A. 1438.3 Large Volume sys Indicate multiple system rooms & indicate ventilation control Yea 1439.1 Kitchen Hoods Indicate source and conditioning of make -up air N.A. 1439.2 Laboratory Exhaust Indicate HR, VAV, semi - conditioned makeup, or CORM calc r r•v••'•�• vnMwa��wwvn. Decision Flowchart ( Start Herd Section 1411.1 Equipment Efficiency Shall Meet Tables 14 -1A through 14 -1G Use flowchart to determine how the requirements of the Complex Systems Option apply to the project. Refer to the indicated Code sections for complete information on the requirements. GBs /Oil Furnace` input ? 225,000 Buh or Any Unit' 'Meat' may. Yes 1411.1110 & Power Venting or Damper. If input ? 225,000 Btuh then 1412.6 Modulating Controls Required • • field- Assembled.., Air Ne` wue c' >..NOI _...�` Equipment? ' No ✓.\ System input 225,000f people Zones? SevingMultipl-e •. No Btuh? . Yes `•1000S�i' Yes Section 1411.1 I..... Section 1412.8 1 0.75% Maximum I I Ventilation Controls Jacket Loss 1 for High-Occupancy Areas Yes ..... — .. Section 1431.1 1 Calculations of Total On -Site Energy Input & Ouput Required J (continued on back) Yes f Section 1432.2.1 Supply Air Reset Controls Required ; L 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Electric Motors MECH -MOT 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised August 2010 ProjeQt Address Taco Time Date 6/15/2011 Complete the following for all design A & B squirrel -cage, T -frame induction permanently wired polyphase motors of 1 hp or more having synchronous speeds of 3600, 1800 or 1200 rpm (unless one of the exceptions below applies). For Building Department Use Motor No. or Location HP Type (open/closed) Description of Application or Use Synch. Speed Min.Nom. Full load Efficiency RTU -1 1 closed Supply air blower motor 3600 86.0% RTU -2 1 closed Supply air blower motor 3600 86.0% Ij4nirr un Boffins! Full -Load Efficiencies (%) As of 12/1912010 Exceptions: 1. Motors in systems designed to use more than one speed of a multi -speed motor. 2. Motors already Included in the efficiency requirements for HVAC equipment (Tables 14- 1A or 14-1B) . 3. Motors that are an integral part (i.e. not easily removed and replaced) of specialized process equipment (Le. equipment which requires a special motor, such as an explosion - proof motor). 4. Motors integral to a listed piece of equipment for which no qualifying motor has been approved (i.e. if the only U.L. listing for the equipment is with a less - efficient motor and there is no energy - efficient motor option). For motors claiming an exception, fist motor and note which exception applies. I Open Motors I Enclosed Pbtorm Synchronous Speed (RPM} 3,600 1,800 1,200 I 3,600 1,800 1200 Motor H P 1.0 77.0 85.5 82.5 77.0 85.5 62.5 1.5 84.0 86.5 86.5 84.0 86.5 87.5 2.0 85.5 86.5 67.5 85.5 86.5 88.5 3.0 85.5 5.5 89.5 88.5 138.5 5 89.5 89.5 5.0 89.5 89.5 88.5 8 89.5 84.5 5 5.0 88.5 91.0 90.2 89.5 .5 91. 10.0 89.5 91.7 91.7 90.2 91.7 91.0 15.0 90.2 93.0 91.7 91.0 92.4 91.7 20.0 91.0 93.0 92.4 91.0 93.0 91.7 25.0 91.7 93.6 93.0 91.7 93.6 93.0 30.0 91.7 94.1 93.8 91.7 93.6 93.0 40.0 92.4 94.1 94.1 92.4 94.1 94.1 50.0 93.0 94.5 94.1 93.0 94.5 94.1 60.0 93.6 95.0 94.5 93.8 95.0 94.5 75.0 93.6 95.0 94.5 93.6 95.4 95.4 100.0 93.6 95.4 95.0 94.1 95.4 95.0 1260 94.1 95.4 95.0 95.0 95.4 95.0 150.0 94.1 95.8 95.4 95.0 95.8 95.8 200.0 95.0 95.8 95.4 95.4 96.2 95.8 250.0 95.0 95.8 95.4 95.8 96.2 95.8 300.0 95.4 95.8 95.4 95.8 96.2 95.8 350.0 95.4 95.8 95.4 95.8 96.2 95.8 400.0 95.8 95.8 95.8 95.8 96.2 95.8 450.0 95.8 98.2 96.2 95.8 96.2 95.8 500.0 95.8 96.2 96.2 95.8 96.2 95.8 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Mechanical'Permit Plans Checklist Continued E MECH -CHK 2009 Washington Slate Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised August 2010 Project Address Taco Time Pate 6/15/2011 The foliowin information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Applicability (yes, no, na) Code Section Component 'Information Required Location on Plans Building Department I Notes SERVICE WATER HEATING AND HEATED POOLS (Sections 1440-1454) 1440 Service water htg. N.A. 1441 Elec. water heater Indicate R -10 insulation under tank N.A. 1442 Shut -off controls Indicate automatic shut -off of circulators or heat trace Yes 1443 Pipe Insulation Indicate R -value of Insulation on piping N.A. 1444 Pump Energy Indicate method of pump energy management (Sec 1438) N.A. 1445 Heat Recovery Indicate preheat capacity as % of peak service water demand. N.A. 1452 Heat Pump COP Indicate minimum COP of 4.0 N.A. 1452 Heater Efficiency Indicate pool heater efficiency N.A. 1453 Pool heater controls Indicate switch and 65 degree control N.A. 1454 Pool covers Indicate vapor retardant cover N.A. 1454 Pools 90+ degrees Indicate R -12 pool cover N.A. 1455 Heat Recovery Indicate method and capacity of exhaust air temperature reduction 1460 Cold Storage N.A. 1463 Evaporators Indicate motor type and speed control N.A. 1464 Condensors Indicate condenser cooling type, design wb temp and control N.A. 1465 Compressors Indicate design minimum condensing temp and control. If "no" is indicated for any item in Sactinna 1d01.149d nr 1ddn.1AAR rovide ex tan t' • , p p a ton. 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Mechanical Permit Plans Checklist. Continued MECH -CHK 2009 Washington State Energy Code Compliance Forams for Nonresidential and Multifamily Residential Revised August 2010 Project Address Taco Time Pate 6/15/2011 The followin information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Applicability (Yes, no, na) I Code Section (Component 'Information Required I Location on Plans I Building Department Notes SERVICE WATER HEATING AND HEATED POOLS (Sections 1440 -1454) 1440 Service water htg. N.A. 1441 Elec. water heater Indicate R -10 insulation under tank N.A. 1442 Shut -off controls Indicate automatic shut -off of circulators or heat trace Yea 1443 Pipe Insulation Indicate R -value of Insulation on piping N.A. 1444 Pump Energy Indicate method of pump energy management (Sec 1438) N.A. 1445 Heat Recovery Indicate preheat capacity as % of peak service water demand. N.A. 1452 Heat Pump COP Indicate minimum COP of 4.0 N.A. 1452 Heater Efficiency Indicate pool heater efficiency N.A. 1453 Pool heater controls Indicate switch and 65 degree control N.A. 1454 Pool covers Indicate vapor retardant cover N.A. 1454 Pools 90+ degrees Indicate R -12 pool cover N.A. 1455 Heat Recovery Indicate method and capacity of exhaust air temperature reduction 1460 Cold Storage N.A. 1463 Evaporators Indicate motor type and speed control N.A. 1464 Condensors Indicate condenser cooling type, design wb temp and control N.A. 1465 Compressors Indicate design minimum condensing temp and control. If "no" is indicated for any item in Seetiens 1af71 -14 i1 nr 1ean.leas nrnvi.ie e.. tft..ft•i..... p FILE COPY ^rrwOA R11,4, Navien America Inc. Tt•ni.nr,as imavoeN Specification Details for the Navien models: CC -240 CC -240A For Potable Water Heating and Space Heating CORRECTION REVIEWED FOR CODE COMPLIANCE APPROVED SEP 13 2011 City of Tukwila BUILDING DIVISION NAVIEN AMERICA INC. 17855 FITCH AVENUE IRVINE, CALIFORNIA, USA 92614 Toll Free: 800 -519 -8794 Tel. (949) 955 -9009 FAX. (949) 955 -9229 http://www.navienamerica.com MtO8O RECEIVED AUG 0 3 2011 PERMITCENTER Accessories included with the Navien water heater: Item Description Qty Navien Condensing Water Heater 1 ' Mar Remote Controller 1 now Dom Operating and Installation Manual ...I@. • •- "' NiIV4 @N 1 Wall Mounting Bracket •. 7111am,; '_...., � �s �_.' -. �, 1 Condensate Drain Hose .�►v ""'0� �►) �earuu[g+ .% il, 1 Tapping Screws & Anchors �:- 4 tv 4 Vent terminators = = 2 Wall Flanges 4 (tf, Q -, 2 Dimensional information: CC -A / CC -A I CR -A -- CC -A ® CR -A - CC -A Type Dimensions Model Oesaription i Diameter A Exhaust 3" B Air Intake 3" C Hot Water Outlet 34" D Recirculation Inlet 3/4" E Cold Water Inlet 34" i F Condensate Drain 3/4" G Gas Connection 3/4" ® CR -A - CC -A Type Dimensions Model 0 1 0 '- 0 180 107" 1 30" 10.4" 17.3" 210 12.7" 30" 12.4" 17.3" 240 12.7" 1 30" 12.4" 17.3" • • 4 .reRUToa riavuem E u 0 3 t ' • Jt t I`'_ '- L .reRUToa riavuem E u 0 3 Dimensional information: CC / CC ICR -CC CR - CC Type Dimensions Model • Description • Diameter A B Exhaust Air Intake . 3" 3" C Hot Water Outlet j 3/4" D Condensate Drain 3/4" E Colo Water Inlet ! 34" F Gas Connection 3/4" CR - CC Type Dimensions Model .O C 0 0 1. O 180 10.7" , 30" 10.4" ' 17.3" 210 12.7" . 30" 12.4" 17.3" 240 12.7" : 30" 12.4" • 17.3" Q 4 rot ).®: V Nawlem 4 --Y 4 NAVIEN CC- 240(A) SPECIFICATIONS: Item CC 240, CC 240A Heat Capacity (Input) Natural Gas Min: 17,000 Btu/h Max: 199,000 Btu/h LP Gas Min: 17,000 Btu/h Max: 199,000 Btulh Hot Water Production Capacity (Oct) 35°F Rise 11 Gahm 46°F Rise 8.6 GaUm 77°F Rise 6.0 GaJm Dimensions W17" x H28" x D12" Weight CC-A 95 Ibs Weight CC 87 Ibs Installation Type Indoor Wall- Hanging Venting Type Forced Draft Direct Vent Ignition Electronic Ignition Water Pressure (min -max) 16 -160 PSI Gas Supply Pressure (from source; min-max) NG: 3" WC - 10.5"WC LP: 8" WC - 13.5" WC 180 Manifold Gas Pressure (min -max) NG: 0.4" WC - 3.7"WC LP: 0.8" WC - 8" WC 210 Manifold Gas Pressure (min -max) NG: 0.4" WC - 3.0"WC LP: 0.8" WC • 6.6" WC 240 Manifold Gas Pressure (min-max) x) NG: 0.4" WC - 4.0"WC LP: 0.8" WC •• 7.1" WC Minimum Flow Rabe 0 GPM for "A" models (no minimum flow rate requirement); 0.6 GPM for non-"A" models Connection Sizes Cold Water Inlet 314" NPT Hot Water Outlet 3/4" NPT Gas Inlet 3/4" NPT Power Supply Main Supply 120VAC, 60Hz Maximum Power Consumption 200W ( 2A) Materials Casing Cold Rolled Carbon Steel Heat Exchangers Primary Heat Exchanger Stainless Steel Condensing Heat Exchanger. Stainless Steel Venting Exhaust (03" & e4 ") 03" PVC (or 03" Type BH Special Gas Vent (Class IIA (PVC) in Canada), 04" Navien Concentric Stainless Steel Intake (o3 ") PVC, Galvanized Steel, Flex Aluminum, Flex Stainless Steel, ABS, Vent Clearances 0" to combustibles Safety Devices Flame Rod, Overheat Cut Off device APFS, GPFS, Gas -Valve Operation Detector, Ignition Operation Detector, Water Temperature High Limit Switch, Exhaust Temperature High Limit Switch Optional Accessories Plumb Easy Valve Set, Venting Kit, Condensate Neutralizer, Condensate Pump, 5 • The Contractor shall supply and install 1 (or more) Navien CC- 240(A) Condensing Residential instantaneous water heater(s); • The contractor may combine multiple CC- 240(A) units to operate as a fully modulating system. Please see the installation manual for detailed multiple unit installation instructions. A connection wire required to Zink multiple CC- 240(A) units together is not included with each CC- 240(A) and is an optional accessory that must be purchased separately; • The dimensions of each CC- 240(A) unit are 28" (H) x 17" (W) x 12" (D); the weight of each CC -240 unit is 87 lbs and each CC- 240(A) unit is 95 lbs. • Each CC- 240(A) unit shall be a fully modulating, low mass, condensing water heater with a modulating input of between 17,000 BTU /H and 199,000 BTU /H and shall have an efficiency of 97.3% and an Energy Factor (EF) of .95; • All Navien water heaters are available in natural gas (NG) or propane gas (LP); field conversions must be completed only by trained factory personnel; unauthorized conversions are not permitted; • The primary heat exchanger shall be a stainless steel, fin -tube exchanger; the condensing (or secondary) heat exchanger shall be a stainless, plate type exchanger, • All intemal waterways to and from the heat exchangers shall be made of stainless steel; • The water heaters' combustion system shall be premixed, forced draft combustion and contain a variable speed fan (DC), an aluminum cast and stainless steel bumer, an electronic spark ignition system with a flame sensing electrode and Navien's GARC control using its APS and GPS technology; • Modulation of the input shall be controlled by an on -board microcontroller (MCU) using thermistors (to sense the input and output water temperatures) and a flow sensor (to measure the volume rate); based on those input values, the MUC and vary the gas flow (through a modulating gas valve) and the fan speed to match the BTU /H output requirements and maintain ideal combustion; • The Contractor must allow sufficient clearances around the water heater. Top of Heater Min. 9 inches Back of Heater Min. 0.5 inches Front of Heater Min. 4 inches Sides of heater Min. 0.5 inches Bottom of heater Min. 12 inches • All Navien units come with an upper mounting bracket pre - drilled at 16" on center for easy installation on standard stud walls. The Contractor shall affix the bracket to the wall securely, ensuring that it is level and that it will support the weight of the water heater. If the strength of the wall is not sufficient, reinforcements must be made to prevent unsafe situations; • The cold water inlet and hot water outlet of each CC- 240(A) are 3 /e" NPT connections. The allowable water pressure range is from 15psi to 150psi. The Contractor shall install manual shut -off ball valves on the cold water inlet and the hot water outlet of each CC- 240(A) unit. In addition, WI union connections and hose bibs are recommended to be installed on the cold water inlet and the hot water outlet of each CC- 240(A) unit to 6 facilitate future maintenance should it be required; • Although the water fittings on the Navien water heater are % ", if the installation site has only 1/2" plumbing throughout the building, it is NOT necessary to upsize the water lines to s /4° when installing a single unit; • When installing multiple units to supply high volumes of hot water either in residential (multi-head shower systems for example) applications or in commemial applications, the number of Navien water heaters required and the header pipe need to be properly sized to meet the total hot water demand; o Each Navien water heater has a temperature high limit shut off switch built in to the outlet water piping as a standard safety feature. Therefore, a "pressure only" relief valve is required to be installed. This unit does not come with a pressure relief valve. The Contractor shall supply an approved 3/4°, maximum 150 psig pressure relief valve and must install it on the hot water outlet, as close to the unit as possible. The maximum input BTU /H rating on the presuure relief valve must be equal to or greater than the maximum199,000 BTU /H input rating of this water heater, • The discharge piping for the pressure relief valve must be directed so that the hot water will not splash on anyone or on nearby equipment. Attach the discharge tube to the pressure relief valve and run the end of the tube to within 6" from the floor. This discharge tube must allow free and complete drainage without any restrictions; No reducing coupling or other restriction may be installed in the discharge line. o This Navien water heater is a high efficiency gas appliance that creates condensation when it operates. This condensation has an acidity (pH) of approximately 4. A condensate trap comes factory installed inside each water heater. A 5 foot length of %" condensate line is included with the water heater. The condensate must be drained in accordance with all local regulations; o Navien recommends draining the condensate to a laundry tub where the soap from the washing machine will neutralize the acidic condensate. If a laundry tub is not close by, Navien recommends the install of a condensate pump to push the condensate to the nearest laundry tub or consider installing a condensate neutralizer, 9 Navien recommends the water heater be the first appliance installed downstream of the gas meter to ensure it will have sufficient supply of gas; o The gas connection fitting on all Navien water heaters is 3/4° NPT. The Contrator must not use less than g/° gas piping. The Contractor shall size the gas line appropriately to ensure a gas supply of 199,000 BTU /H per unit is delivered; O The allowable natural gas supply pressure range is from 3° W.C. to 10.5" W.C. For optimal performance, a minimum of 7" WC is recommended. The Navien water heater will automatically reduce the hot water volume production if the gas supply pressure is insufficient to meet demand; O When using flexible gas line, ensure the pipe's inner diameter is sufficient to supply the required BTU /Hs. Ensure the flexible line has no crimps or tight bends that will restrict gas flow. The Contractor shall install a manual gas shut -off valve between on the gas supply line close to the water heater, o When using rigid gas pipe, the Contractor shall install a union on the gas supply pipe close to the water heater to facilitate any future maintenance and service; o Navien recommends whenever possible, that its water heaters be used as direct vent (or sealed combustion) units which draw all of their required combustion air directly from outside the building and where the combustion air supply is connected directly to the air intake collar of the water heater. • If, in the room .in which the unit is to installed, there is a continuous and sufficient supply of combustion and ventilation air in accordance with all local codes, the Navien units may then communicate with that indoor air and a direct outdoor supply is not required. This non - direct vent method of venting is not recommended for residential installations in areas subject to below freezing air temperatures; • All Navien water heaters use round 3" exhaust and round 3" air supply vent pipe. To ensure the draw and exhaust of air directly to and from the outside, the exhaust vent and air intake vent must be sealed airtight from unit collar to terminator, • The air intake vent materials may be made of ABS, PVC, galvanized steel, corrugated aluminum or any other such materials. If using a corrugated material, ensure there is no inadvertent crimping of, or damage to, the air intake vent. Maximum allowable intake vent length, either vertically or horizontally, is 100' subtracting 5' for each 90 °elbow and 2' for each 45° elbow in the venting system to a maximum of 6 elbows. Each CC- 240(A) may be sidewall vented (horizontally) or vented through the roof (vertically). • This Navien water heater may be vented with plastic or stainless steel. Plastic vent may be used in all cases EXCEPT when the incoming or recirculation return water temperatures exceed 160 °F (70 °C). IF you set the water heater at a temperature higher than 160 °F (70 °C) AND are running an external recirculation loop or a combination heating system, you MUST use the Navien 4" concentric stainless steel venting or any 3" venting system approved for use with Category IV appliances for temperatures above 65 °C (typically Type BH Special Gas Vent Class II B, C or D approved to UL1738- S636). Navien Recommended Vent Materials Model Type USA CANADA CC -240, CC- 240A PVC Schedule 40** ABS Schedule 40** Navien's Stainless Steel Vent Kit Navien's Stainless Steel Vent Kit or Type BH Special Gas Vent Class IIA (PVC) ** ** except cellular core • The water heaters shall be exhaust vented with 3" PVC (in Canada, Special Gas Vent - Type BH Class IIA certified to UL1738/ULC -S636 approved for use with Category IV appliances). Maximum allowable vent length, either vertically or horizontally, is 100' subtracting 5' for each 90 °elbow and 2' for each 45° elbow in the venting system to a maximum of 6 elbows. Each CC- 240(A) may be sidewall vented (horizontally) or vented through the roof (vertically). There shall be an upward slope of %" per foot (2 %) from the flue collar of the unit to venting system terminator; • When installing multiple Navien water heaters, the exhaust venting may be combined into a common vent. The multi-unit system software design is such that the fan in each individual unit will begin automatically when the burner of any unit fires creating a positive pressure in the common vent. The size of the common vent trunk line is dependent on the number of units installed. The table below identifies the inner diameter requirement of the truck line given the total number of units installed in the multi- system: 8 IS of Units in Multi - System Required Minimum Diameter of Common Vent Trunk Line 2 units 4" 3 units 4" 4 units 6" 5 units 6" 6 units 8" 7 units 8" 8 units 10" 9 units 10" 10 units 12" • A ventilation air opening of sufficient size shall be provided if necessary in accordance with all local codes; • The electrical supply required by the water heater is 110- 120VAC at 60 Hz with a maximum 2 A rating; • All units come with a factory installed 3- pronged (grounded) plug end. The water heater may be plugged into any electrical outlet close to the unit. It is not necessary to run a dedicated electrical line to the water heater; • If the local jurisdiction requires the unit to be wired directly, the Contractor may remove and discard the factory installed plug. An on/off switch controlling the main power between the breaker and the Navien water heater must be provided to facilitate end - user maintenance and servicing; • The heater must be electrically grounded. Ensure the electical receptacle, in which the water heater will be plugged into, is properly grounded; if wiring directly, do not attach the ground wire to either the gas or the water piping as plastic pipe or dielectric unions may isolate the water heater electrically; • Do not plug electrical power to the unit until all plumbing and gas piping is complete and the water heater has been filled with water; • Disconnect the power to the water heater before installing the remote control; • The remote control connects to the computer board inside the water heater using 18 gauge wire; DO NOT connect 110- 120VAC to this remote control; • The maximum length of wire between the water heater and the remote control installation location is limited to a maximum of 300 feet; • There is no polarity; • The remote control is water resistant but not water proof; • The standard parts warranty is 3 years on all components except for the heat exchanger which has a 6 year warranty. • Navien America Inc. is continuously improving our products therefore specifications are subject to change without prior notice. • Follow all local codes, or in the absence of local codes, follow the most recent edition of the National Fuel Gas Code (ANSI Z223.1/NFPA 54) or the CAN /CSA- B149.1 -05 Natural Gas and Propane Installation Code. 9 • Flow Rates: Flow Rate Specifications NCCn 240A Navien CC 240 Output BTU (NG) 195,020 195,020 Combustion Efficiency (NG) 98% 9 8% Input BTU (NG) 199,000 199,000 GPM @ 35 °F Temperature Rise (70 °F to 105 °F for example) (theoretical value based on BTUs; may be subject to manufacturer's heat exchanger flow limits) 11.1 11.1 GPM © 45 °F Temperature Rise (60 °F to 105 °F for example) (theoretical value based on BTUs: may be subject to manufacturer's heat exchanger flow limits) 8.7 8.7 GPM @ 50 °F Temperature Rise (70 °F to 120 °F for example) 7.8 7.8 GPM @ 55 °F Temperature Rise (65 °F to 120 °F for example) 7.1 7.1 GPM @ 60 °F Temperature Rise (60 °F to 120 °F for example) 6.5 6.5 GPM @ 65 °F Temperature Rise (55 °F to 120 °F for example) 6.0 6.0 GPM @ 70 °F Temperature Rise (50 °F to 120 °F for example) 5.6 5.6 GPM @ 75 °F Temperature Rise (45 °F to 120 °F for example) 5.2 5.2 GPM © 80 °F Temperature Rise (40 °F to 120 °F for example) 4.9 4.9 # of Simultaneous Showers with 40 °F Ground Water (2.5 GPM Heads) 2.4 2.4 # of Simultaneous Showers with 55 °F Ground Water (2.5 GPM Heads) 3.2 3.2 # of Simultaneous Showers with 70 °F Ground Water (2.5 GPM Heads) 4.6 4.6 10 Pressure Drop Chart: •c0 90 8c 7C 60 40 30 ,,C. 10 0 Pressure Drop —0— cc:CR- 210!2 CA:22410.240A ZC;CR- 180,'ISCA 3 Water Flow Rate (GPM) b 8 4! 40 35. 3C a 20 10 Pressure Drop '-0 -cC •CR- ^_tw ^_IOA:2- 0:_ =3A CC ' CR - 8G: 18C•A 0 3 4 5 Water Flow Rate (GPM) 8 11 11 -01 -2011 • City of Tukwila 4 Jim Haggerton, Mayor Department of Community Development Jack Pace, Director HOWARD G KIMURA HG KIMURA ARCHITECT PO BOX 59415 98058 RE: Permit Application No. M11 -080 TACO TIME 15037 TUKWILA INTERNATIONAL BL TUKW Dear Permit Applicant: In reviewing our current application files, it appears that your permit applied for on 06/16/2011, has not been issued by the City of Tukwila Permit Center. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and /or National Electrical Code every permit application not issued within 180 days from the date of application shall expire and become null and void. Your permit application will expire on 12/13/2011. If you still plan to pursue your project, a written request for extension of your application must be submitted to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit application. If it is determined that an extension is granted, your application will be extended for an addtional 90 days from the expiration date and you will be notified by mail. In the event that we do not receive your written request for extension or request was denied, your permit application will expire, become null and void and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, c —V__ Bill Rambo Permit Technician File: Permit File No. M11 -080 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 • • ABOSSEIN ENGINEERING, LLC August 31, 2011 I.. CI l',,f 41t1'fl,�Nl ;'A. i :vi f u(r rf:UIurt uy;\ f.rrn Dave Larson City of Tukwila Community Development Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA Ref: Taco Time Restaurant, 15037 Tukwila Int.. Blvd, Permit #M11080 Dear Mr. Larson: Below are responses to your letter datcd August 25. 2011 — Building Revision Review Merno2. 1. See Sheet M03 for requested roof Blau. 2. See revised Sheet 1■401 for hood section. 3. Sec revised Sheet P03 for water heater riser diagram. Please contact. me, if any additional questions or information is needed. Sincerely, qft Gernac/, Gary Womack Mechanical Dept. CORRECTION LTR# Z t,'t 1toao RECEIVED SEP 07 2011 PERMIT CENTER 2100 112111 Avenue NE, Suite 201 • [Bellevue, OVA 98004 0 PH: 425/462 -9441 • FAX: 425/462 -9451 0 EMAIL: general @abosscin.com 0 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director August 26, 2011 Howard Kimura HG Kimura Architect PO Box 59415 Renton, WA 98058 RE: Correction Letter #2 Mechanical Permit Application Number M11 -080 Taco Time —15037 Tukwila International BI Dear Mr. Kimura, This letter is to inform you of corrections that must be addressed before your mechanical permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. The Fire Department has no concerns at this time. Building Department: Dave Larson at 206 431 -3678 if you have any questions regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3670. hAltjAL4 shall ician enc File: M11 -080 W:\Permit Center \Comction Letters \2011\M11 -080 Correction Letter #2.doc 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 • Tukwila Building Division Dave Larson, Senior Plan Examiner Building Division Review Memo #2 Date: August 25, 2011 Project Name: Taco Time Permit #: M11 -080 Plan Review: Dave Larson, Senior Plans Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and /or other applicable documentation. 1. We will need a roof plan submitted with this mechanical permit application to show required clearances of the mechanical equipment. The one you refer to in your response was submitted with the building permit application. It shows a 10 ft. circle around the hood exhaust intersecting one of the HVAC units. The air intake of the HVAC unit is not shown and needs to be to verify clearance. 2. Please provide a cross - section of the hood installation to show exhaust duct protection, exhaust termination, hood clearances and adjoining construction. 3. Please provide a cross - section of the tankless water heater installation to show type, location and termination of venting. Show make -up air also. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) Should there be questions concerning the above requirements, contact the Building Division at 206 -431- 3670. No further comments at this time. H.G. KI MU RA A1it.:11 1111.1.1'1I Howard G. Kimura, Principal August 1 2011 Mr. Bill Rambo. Permit Technician City of Tukwila Dept. of Community Development 6300 Southcenter Blvd. Suite 100 Tukwila, WA 98188 RE: Tukwila Taco Time Mechanical Permit Application No. M11 -080 15037 Tukwila International Blvd Tukwila, WA Dear Mr. Rambo. We are in receipt of your letter dated Jul- 8`h, 2011 and will respond to the comments in the same order received: BUILDING DIVISION REVIEW ( Mr. Dave Larson): 1. Refer to letter from Mechanical Engineer (see sheet labeled A) 2. Refer to letter from Mechanical Engineer (see sheet labeled A) 3. Refer to letter from Mechanial Engineer (see sheet labeled A) 4. Refer to letter from Mechanical Engineer (see sheet labeled A) 5. Refer to sheet Floor Plan, Sheet A2.1, the roof hatch is labeled next to Food Prep 107. Or, Reflected Ceiling Plan, Sheet A4.2 for roof plan showing the location of the roof hatch and a cross section. This is in the original set of drawings. FIRE PREVENTION BUREAU REVEIW ( Mr. Al Metzler): 1. Refer to Hood Drawings HI thru H3, attached as part of the resubmittal. This concludes our response to agency comments with regard to the mechanical permit. Please call me if you have further questions on the above. We would like to thank you in advance for your assistance on our project. Sincerely, HG Kimura Architect PLLC CORRECTION Howard G. Kimura, Principal M U RECEIVED AUG 0 3 2011 PERMITCENTER 18012 West Lake Desire Drive Southeast • Renton, Washington 98058 • Tel: 425.766.5000 • Fax: 425.271.2383 • email: hgkimura @comcast.net July 26, 2011 Dave Larson City of Tukwila Community Development Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA Ref: Taco Time Restaurant, 15037 Tukwila Int. Blvd Dear Mr. Larson: Below are responses to your letter dated July 8, 2011— Building Revision Review. 1. There is no drop ceiling in the Dining Room. All ductwork is exposed. 2. See submitted hood drawings from CaptiveAire. 3. See architectural roof plan for rooftop equipment layout. 4. See attached installation guide for tankless water heater. 5. See architect's response. Please contact me, if any additional questions or information is needed. Sincerely, Gary Womack Mechanical Dept. CORRECTION RECEIVED LTR # AUG 03 2011 PERMIT CENTER MtlO8O 2100 112th Avenue NE, Suite 201 • Bellevue, WA 98004 • PH: 425/462 -9441 • FAX: 425/462 -9451 • EMAIL: general@abossein.00m July 8, 2011 • Gity of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director Howard Kimura HG Kimura Architect PO Box 59415 Renton, WA 98058 RE: Correction Letter #1 Mechanical Permit Application Number M11 -080 Taco Time —15037 Tukwila International Bl Dear Mr. Kimura, This letter is to inform you of corrections that must be addressed before your mechanical permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building and Fire Departments. Building Department: Dave Larson at 206 431 -3678 if you have any questions regarding the attached memo. Fire Department: Al Metzler at 206 971 -8718 if you have questions regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3670. Sincerely` ,Q Bill Rambo Permit Technician encl File: M 11 -080 W:\Pennit Center\Correction Letters \2011\M11 -080 Correction Letter #1.doc 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 Tukwila Building Division Dave Larson, Senior Plan Examiner Building Division Review Memo Date: July 7, 2011 Project Name: Taco Time Permit #: M11 -080 Plan Review: Dave Larson, Senior Plans Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and /or other applicable documentation. 1. It is not clear if the return air is ducted to the ceiling grid or not. Combustible spaces above the ceiling can't be used as a plenum. Please show ducted returns if this is the case or add notes to the plans to clarify. 2. Note (1) in the kitchen grease hood schedule says refer to hood drawings for additional information. We did not get these drawings. 3. Please provide a rooftop plan to show required separations between intakes and outlets and separation as required between kitchen hood exhaust and parapet sidewalls if applicable. 4. Please provide the installation specs. for the tankless water heater venting, An elevation or side view may be helpful. 5. Is rooftop access provided for equipment access? Please provide details for location, ladder, and hatch if applicable. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) Should there be questions concerning the above requirements, contact the Building Division at 206 -431- 3670. No further comments at this time. Tukwila Fire Prevention I3ureau AI Metzler, Fire Project1Coordinator Fire Prevention Bureau Review Memo Date: June 22, 2011 Project Name: Taco Time Address: 15037 Tukwila International BI Permit #: MI 1 -080 Plan Reviewer: Al Metzler, Fire Project Coordinator The Fire Prevention Bureau conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and /or other applicable documentation. 1. The scope of work description includes the installation of a Type I and a Type II hood. However, there are no hood details included in the submittal. Please include the hood details or remove the hoods from the scope of work description and apply for a separate mechanical permit. Should there be questions concerning the above requirements, contact the Fire Prevention Bureau at 206- 971 -8718. No further comments at this time. E 1 PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M11 -080 DATE: 09 -07 -11 PROJECT NAME: TACO TIME SITE ADDRESS: 15037 TUKWILA INTERNATIONAL BL Original Plan Submittal X Response to Correction Letter # 2 Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: uilding ivision Public Works Fire Prevention Structural Planning Division ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete DUE DATE: 09 -08 -11 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ LETTER OF COMPLETENESS MAILED: Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route Structural Review Required No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 10-06-11 Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 • P PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M11 -080 DATE: 08 -03 -11 PROJECT NAME: TACO TIME SITE ADDRESS: 15037 TUKWILA INTERNATIONAL BL Original Plan Submittal Response to Incomplete Letter # X Response to Correction Letter # 1 Revision # After Permit Issued DEPA THE TS: uilding Div slonv u Public Works ❑ IAA 74c-- 'Fire Prevention Structural i • P PLAN R 0 VIEW /ROUTING SLIP ACTIVITY NUMBER: M11 -080 DATE: 06 -16 -11 PROJECT NAME: TACO TIME SITE ADDRESS: 15037 TUKWILA INTERNATIONAL BL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPA TMENTS: bding Division t J Public Works n 4w\ (�a \ ' ,- I I ire PreJention Structural ❑ Planning Division Permit Coordinator 11 DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete DUE DATE: 06 -21 -11 Not Applicable n Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required nNo further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 07 -19 -11 Not Approved (attach comments) Kf DATE: Permit Center Use Only CORRECTION LETTER MAILED: --g-1 I Departments issued corrections: Bldg Fire' Ping ❑ PW ❑ Staff Initials: U Documents/routing slip.doc 2 -28 -02 i City of Tukwila Department of Comnuinity Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Web site: littp://NNw■N.TukwilaWA.gov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: Plan Check/Permit Number: A4it - D(r0 Response to Incomplete Letter # Response to Correction Letter # f Revision # after Permit is Issued Revision requested by a City Building Inspector or Plans Examiner Project Name: Project Address: SD OP Person: N�At�I /t f,.-n4, -7, Phone Number: 424- -7 G G - J vdd Summary of Revision: /2%490i—el d," VOW 1-24 VYD a, Go K- r- r-rcord f Xoa Afb /47771-0l f CG1lo ti neae4 S t Gkiffi fee4601.1 TK.wilei R Go 71ti-7 �. 15a 31 TNk4 4 4h Jam ,t3) s4 Sheet Number(s): M' / ',440 K PO / - P93 "Cloud" or highlight all areas of revision including da Received at the City of Tukwila Permit Center by: 'Entered in Permits Plus on t 7 t fiLGEMED Crty OF TUKWILA SEP 0 7 2011' NIRMIT CENTER H:Wpplications \Forms - Applications On Line \2010 Applications \7 -2010 - Revision Submittal.doc Revised: May 2011 • 0 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431 -3670 Fax: 206 -431 -3665 Web site: http: //www.ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: d'=L —// Plan ChecWPermit Number: M11-080 ❑ Response to Incomplete Letter # ®. Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Taco Time Project Address: 15037 Tukwila International B1 Contact Person: ar71( Phone Number: _ 2 i — 74 b p Summary of Revision: 41-0 fi o -fit �{Ut -4 � M -e-4( � neceessa n of AUG :0 3 2011 PERMITCENTER Sheet Number(s): 441, / 12,, }/- 3 "Cloud" or highlight all areas of revision including date of re • i n (3.1 W Received at the City of Tukwila Permit Center by: [ Entered in Permits Plus on 8- 3 t1! \applicatiionslforms- applications on linerevision submittal Created: 8 -13 -2004 Revised: Contractors or Tradespeople *ter Friendly Page 0 General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name EMERALD AIRE INC UBI No. 600591552 Phone 2538725665 Status Active Address 5108 D Street Nw License No. EMERAAI055BL Suite /Apt. License Type Construction Contractor City Auburn Effective Date 1/13/1995 State WA Expiration Date 4/1/2013 Zip 98001 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status SOUNDAI1580W SOUND AIR INC Construction Contractor General Unused 9/16/1985 8/15/1995 Archived Business Owner Information Name Role Effective Date Expiration Date HAPPE, DOUGLAS A President 01/01/2000 Bond Amount RIDGE, JOHN PATRICK Vice President 01/01/2000 1977929 RICHARDS, RON Secretary 01/13/1995 06/01/2000 TREMAINE, DAVIS WRIGHT Agent 01/13/1995 12/31/1999 DUPUIS - FRICKE, LINDA President 01/13/1995 12/31/1999 HAPPE, DOUGLASA President 01/13/1995 12/31/1999 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 4 THE HANOVER INSURANCE COMPANY 1977929 01/01/2011 Until Cancelled $12,000.0001/06 /2011 3 INS CO OF THE WEST 1352839 10/18/2001 Until Cancelled 01/01/2011 $12,000.00 03/29/2002 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 16 Continental Western Ins Co CWP2434476 04/01/2011 04/01/2012 $1,000,000.00 03/08/2011 15 Continental Western Ins Co CWP2434476 04/01 /2010 04/01 /2011 $1,000,000.0003 /29/2010 14 Continental Western Ins Co CWP2434476 04/01/2009 04/01/2010 $1,000,000.00 03 /20/2009 13 CONTINENTAL WESTERN INS CO CWP2434476 04/01/2008 04/01/2009 $1,000,000.00 03/18/2008 12 CONTINENTAL WESTERN INS CWP2434476 04/01/2007 04/01/2008 $1,000,000.0003 /09/2007 11 CONTINENTAL WESTERN INS CWP2434476 04/01 /2006 04/01 /2007 $1,000,000.00 03/16/2006 https://fortress.wa.gov/lni/bbip/Print.aspx 11/15/2011 E a, 0 0 0) 0 0) 0 0 0 0 0 J w z 1- 0 : \211047 \211047_MO REVDATE: FILE NAME: GENERAL NOTES 1) COMPLETE INSTALLATION OF THE MECHANICAL SYSTEM SHALL BE PER THE CITY OF TUKWILA'S BUILDING, MECHANICAL, ENERGY, PLUMBING, FIRE AND HEALTH CODES AND REGULATIONS AS ADOPTED BY THE LOCAL JURISDICTION. 2) ALL AIR - CONDITIONING UNITS WITHOUT INTERNAL TRAP SHALL HAVE A P -TRAP FOR THE CONDENSATE PAN WITH PLUG TEES FOR CLEANING AND CONDENSATE PIPES SHALL BE DISCHARGED TO EXISTING CONDENSATE WASTE PIPING. VERIFY SIZE AND LOCATION AT SITE. 3) MECHANICAL CONTRACTOR SHALL COORDINATE DIFFUSER LOCATIONS AND DUCT ROUTING CLEARANCES WITH THE STRUCTURAL, REFLECTED CEILING AND LIGHTING PLANS. 4) PLUMBING CONTRACTOR SHALL COORDINATE PLUMBING VENT STACKS WITH THE EQUIPMENT TO MAINTAIN A MINIMUM OF 10 FT. FROM THE OUTSIDE AIR INTAKES. 5) ALL FIRE RATED STRUCTURE SHALL BE FIRE DAMPERED. VERIFY WITH THE ARCHITECTURAL AND INSTALL PER THE LOCAL JURISDICTIONS. 6) ALL AIR DISTRIBUTION OUTLETS SHALL HAVE VOLUME CONTROL DEVICES. 7) ALL VOLUME DAMPERS IN NON- ACCESSIBLE CEILINGS SHALL HAVE A CONTROL ARM EXTENDED TO AN ACCESSIBLE LOCATION ( "YOUNG" REGULATIONS OR EQUAL). EXACT LOCATION OF CONTROL DEVICES VISIBLE IN FINISHED SPACES SHALL BE COORDINATED WITH THE ARCHITECT. 8) ALL 90 DEGREE TRUNK DUCT ELBOWS SHALL BE SMOOTH -ROUND OR SQUARE WITH TURNING VANES. 9) MECHANICAL CONTRACTOR SHALL LOCATE AND COORDINATE EXACT LOCATION OF PIPING AND DUCTWORK AND PENETRATIONS WITH THE STRUCTURE. 10) MAXIMUM LENGTH OF FLEXIBLE DUCTS SHALL BE 6' OR AS SHOWN ON DRAWINGS. 11) ALL DUCTWORK, EQUIPMENT AND PIPING SHALL BE SEISMICALLY SUPPORTED PER SMACNA AND LOCAL REGULATIONS. 12) ALL AIR FILTERS SHALL HAVE EFFICIENCY BASED ON THE ASHRAE STANDARD 52 -76 (ATMOSPHERIC DUST SPOT). 13) ALL MECHANICAL EQUIPMENT SHALL CONFORM TO SMACNA AND LOCAL REGULATIONS FOR SEISMIC RESTRAINT (INCLUDING PIPING AND DUCTWORK). 14) ALL EQUIPMENT AND ACCESSORIES IN CONCEALED SPACES REQUIRING ACCESS SHALL HAVE ACCESS DOORS. 15) TOTAL SYSTEM SHALL BE WARRANTED FOR ONE YEAR; STARTING FROM THE TIME OF OWNER /ENGINEER'S FINAL ACCEPTANCE. 16) HVAC NOTES: A) PROVIDE FLEXIBLE CONNECTION IN ALL DUCTS CONNECTING TO AIR MOVING EQUIPMENT AS CLOSE TO FAN AS POSSIBLE. FLEXIBLE CONNECTION SHALL CONSIST OF 6" OR • MORE OF AIR TIGHT, FIREPROOF FLEXIBLE NEOPRENE COATED WOVEN FIBROUS GLASS MATERIAL. VENT FABRICS, INC. OR APPROVED EQUAL. B) ALL DUCTWORK SHALL BE SHEET METAL. SOUND LINE RECTANGULAR SUPPLY AND RETURN DUCTS WITHIN 10 FEET FROM THE UNIT OPENINGS. C) ALL SUPPLY AND RETURN FLEXIBLE DUCTS SHALL BE CONSTRUCTED OF DOUBLE LAMINATION OF POLYESTER ENCAPSULATED STEEL WIRE HELIX FOR INNER CORE HIGH DENSITY FIBERGLASS INSULATION AND GRAY POLYESTER FILM WITH SPIRAL REINFORCEMENTS EQUAL TO "ATCO -70 SERIES" (MIN. POS. PRESS. = 6" W.G., NEG. PRESS = 0.75" W.C.). FLEXIBLE DUCTS AND CONNECTORS SHALL BE U.L. 181 LISTED AND MEET ALL REQUIREMENTS OF IMC 603.6. D) PROVIDE LOCKABLE VOLUME DAMPERS IN ALL AIR DISTRIBUTION OUTLETS. E) DUCT HANGERS, SUPPORTS AND METHODS OF INSTALLATION SHALL CONFORM TO ASHRAE AND SMACNA RECOMMENDATIONS. F) DUCT SIZES SHOWN ON PLANS INDICATE INSIDE FREE AREA. G) ALL DUCTWORK SHALL BE CLASS 1 AIR DUCT AS APPROVED BY U.L. -181. H) DUCTS - SHEET METAL DUCTS SHALL BE INSULATED WITH THE INSULATION AND THICKNESSES AS SHOWN HEREIN (REDUCE THE INSULATION THICKNESS BY THERMAL VALUE OF SOUND LINING). 1. SUPPLY AIR DUCTS IN HEATED SPACE; NO INSULATION REQUIRED IF SOUNDLINED, OTHERWISE 1" THICK K = 0.23 © 75 DEGREES F. 2. SUPPLY AIR DUCTS IN NON- HEATED SPACE; APPROXIMATELY 3" THICK K =0.23 (4 75 DEGREES F., TO PROVIDE A MINIMUM THERMAL RESISTANCE VALUE OF MINIMUM R -11. 3. SUPPLY AIR DUCTS OUTSIDE OF BUILDING SAME AS CONDITIONED SPACE EXCEPT WITH WEATHERPROOF BARRIER. 4. RETURN AIR DUCTS; SHALL HAVE SAME INSULATION AS THE SUPPLY AIR DUCTS. 5. EXHAUST AIR DUCTS; NO INSULATION REQUIRED. 6. INDOOR DUCTS HANDLING OUTSIDE AIR SHALL HAVE FIBERGLASS BLANKET WITH VAPOR BARRIER JACKET ASJ, 1" THICK, K = 0.23 ® 75 DEGREES F. (ALL DUCTWORK FOR THE BUILDING SUPPLY FAN AND OUTSIDE AIR INTAKES TO INDIVIDUAL HEAT PUMPS). 17) DUCTWORK ALL DUCT SIZES SHOWN ON PLANS INDICATED INSIDE FREE AREA. ALL DUCTWORK SHALL BE CLASS 1 AIR DUCT AS APPROVED BY U.L. -181. A. INSTALL ALL DUCTWORK IN CONFORMANCE WITH RECOMMENDED CONSTRUCTION STANDARDS FOR RECTANGULAR AND ROUND SHEET METAL AND FLEXIBLE DUCTS IN ACCORDANCE WITH SMACNA DUCT CONSTRUCTION STANDARDS AND ALL OTHER AUTHORITIES HAVING JURISDICTION. MINIMUM SHEET METAL THICKNESS SHALL BE 26 GA. B. ALL DUCT JOINTS LONGITUDINAL AND TRANSVERSE ARE TO BE SEALED USING 181A OR 181B LISTED TAPES AND MASTICS. MECHANICAL FASTENERS MUST BE USED TO FASTEN DUCTS. C. STRAP HANGERS SHALL NOT BE LESS THAN 1" BY 1/8" THICK ON SIX (6) FOOT CENTERS AND ATTACHED TO SIDE OF DUCT WITH SHEET METAL SCREWS. INSULATED FLEXIBLE DUCT MAY BE USED FOR LOW PRESSURE RUN OUTS TO INDIVIDUAL DIFFUSERS IN LENGTHS NOT TO EXCEED FIVE (5) FEET FOR EACH DIFFUSER. SEAL ALL SHEET METAL SCREW PENETRATIONS. D. ALL RECTANGULAR AND ROUND SUPPLY DUCTWORK SHALL BE EXTERNALLY INSULATED WITH A MINIMUM THICKNESS THAT CONFORMS TO THE STANDARD OF THE LOCAL CODE AND SHALL AND SHALL HAVE A CONTINUOUS VAPOR BARRIER JACKET W /ALL JOINTS TAPED AND SEALED. FRESH AIR DUCT SHALL HAVE 2" INTERNAL DUCT LINER FROM POINT OF OUTSIDE AIR CONNECTION TO POINT OF CONNECTION AT PLENUM BOX OR MIXING BOX. ALL EXPOSED SPIRAL DUCT SHALL HAVE INTERNAL DUCT LINER. E. ALL INSULATION, JOINING MATERIALS, SEALER, ETC.. SHALL HAVE A U.L. FLAME SPREAD CLASSIFICATION OF NO MORE THAN 25 AND A SMOKE DEVELOPMENT RATING NOT MORE THAN 50. 18) MECHANICAL CONTRACTOR SHALL LOCATE AND COORDINATE THE EXACT LOCATION OF DUCTWORK WITHIN THE STRUCTURE WITH STRUCTURAL AND GENERAL CONTRACTOR PRIOR TO INSTALLATION OF ANY STRUCTURE OR EQUIPMENT. 19) ALL DUCT PENETRATIONS THROUGH RATED ENCLOSURES SHALL BE FIRE AND /OR SMOKE DAMPERED. 20) ALL ROOF PENETRATIONS SHALL BE MIN. OF 5 FEET AWAY FROM THE 2 -HR AREA SEPARATION WALLS. ALL PIPE, DUCT AND CONDUIT PENETRATIONS THROUGH RATED ASSEMBLIES SHALL BE FIRE AND SMOKE STOPPED PER CODE. 21) ALL MECHANICAL EQUIPMENT SHALL CONFORM TO SMACNA AND LOCAL REGULATIONS FOR SEISMIC RESTRAINT (INCL. PIPING AND DUCTWORK). 22) THE CONTRACTOR SHALL NOT OPERATE THE EQUIPMENT FOR TEMPORARY HEATING OR VENTILATION DURING THE CONSTRUCTION. (ALL EQUIPMENT SHALL RUN FOR TESTING AND BALANCING PURPOSES ONLY). NOTIFY THE ENGINEER 48 HOURS (MINIMUM) IN ADVANCE TO ARRANGE A FINAL FIELD INSPECTION PRIOR TO COVERING UP THE CEILING. 23) EACH FAN UNIT OVER 2000 CFM SHALL HAVE A DUCT SMOKE DETECTOR CTOR PER 2009 IMC 606 IN RETURN DUCTS AS REQUIRED BY THE JURISDICTIONS. UNIT SHALL SHUT DOWN UPON SMOKE DETECTION (COORDINATE WITH FIRE ALARM CONSULTANT /CONTRACTOR PRIOR TO BIDDING/ CONSTRUCTION). 24) CONTRACTOR IS TO BRING UP THE DISCREPANCIES AND ITEMS WHICH ARE NOT SPECIFICALLY CALLED FOR OR SHOWN BUT ARE REQUIRED FOR A COMPLETE MECHANICAL SYSTEM AND AFFECT HIS CONTRACT PRIOR TO ENTERING AND SIGNING THE CONTRACT; AFTER AWARDING THE . CONTRACT ALL SUCH ITEMS REQUIRED FOR A COMPLETE SYSTEM READY FOR THE OWNER'S BENEFICIAL USE SHALL BE FURNISHED AND INSTALLED INCLUDING ALL SUCH DISCREPANCY ITEMS MENTIONED ABOVE, AT NO ADDITIONAL COST TO THE OWNER AND PER LOCAL CODES. MANUFACTURER'S RECOMMENDATIONS AND APPLICABLE STANDARDS WITH THE ARCHITECT /ENGINEER'S APPROVAL. 25) ALL EQUIPMENT SUPPLIED FOR THESE SPECIFICATIONS SHALL BE FREE FROM DEFECTS IN MATERIAL, WORKMANSHIP, AND TITLE, AND SHALL BE OF THE KIND AND QUALITY DESCRIBED HEREIN. IF IT APPEARS WITHIN ONE YEAR FROM DATE OF FINAL ACCEPTANCE THAT EQUIPMENT DOES NOT MEET THE WARRANTIES ABOVE, THE CONTRACTOR SHALL IMMEDIATELY CORRECT ANY DEFECT AND SHALL RESTORE THE SYSTEM TO THE ORIGINAL SATISFACTORY CONDITIONS AT HIS EXPENSE. THE FOREGOING WARRANTY IS EXCLUSIVE AND IN LIEU OF OTHER WARRANTIES, WHETHER WRITTEN, ORAL, IMPLIED OR STATUTORY. NO WARRANTY OF MERCHANT ABILITY OF FITNESS FOR PURPOSE SHALL APPLY. (THE WARRANTY SHALL START FROM THE TIME OF ARCHITECT /ENGINEER'S FINAL ACCEPTANCE.) 26) ENTIRE INSTALLATION OF ALL EQUIPMENT, CONTROL, PIPING, DUCTWORK AND RELATED ACCESSORIES SHALL BE PER BASIC OWNERS' STANDARDS. MECHANICAL CONTRACTOR IS TO FAMILIARIZE HIMSELF WITH THESE STANDARDS. 27) MECHANICAL CONTRACTOR SHALL VISIT THE SITE AND VERIFY THE ROUTING AND INSTALLATION FEASIBILITY OF ALL EQUIPMENT, PIPING AND DUCTWORK PRIOR TO SUBMITTING HIS BID AND INCLUDE IN HIS BID ADDITIONAL PIPING, DUCTWORK, FITTINGS, OFFSETS, ETC. WHICH MIGHT BE REQUIRED FOR A COMPLETE SYSTEM READY FOR OWNER'S BENEFICIAL USE. 28) COORDINATE THE CONSTRUCTION SCHEDULE WITH THE ARCHITECT AND PERFORM ALL REQUIRED WORK IN STRICT ACCORDANCE WITH THE OWNER'S SCHEDULE. 29) MECHANICAL CONTRACTOR SHALL PAY FOR AND OBTAIN ALL REQUIRED PERMITS AND CERTIFICATES REQUIRED BY THE AUTHORITIES HAVING JURISDICTION. 30) ADJUST ALL EQUIPMENT AND PERFORM A COMPLETE AIR - BALANCING AND PUT ALL MECHANICAL SYSTEMS IN OPERATION AND SUBMIT MINIMUM 4 COPIES OF BALANCING REPORTS TO THE OWNER /ARCHITECT. GAS ROOFTOP AIR- CONDITIONING SCHEDULE DESIGNATION: RTU -1 RTU -2 ZONE: DINING KITCHEN MANUFACTURER: TRANE "PRECEDENT" TRANE "PRECEDENT" MODEL: YSC -092 YSC -092 DISCHARGE: DOWN DOWN GAS TYPE: NAT. NAT. NOMINAL TON OF CLG 7.5 7.5 COOLING © ARI (MBH): 94.0 94.0 HEATING INPUT (MBH): 120 120 HEATING OUTPUT (MBH): 96.2 96.2 E.E.R.: 11.2 11.2 IPLV -- -- AFUE: (STEADY STATE) (80 %) (80 %) FAN MOTOR DRIVE: BELT BELT CFM: 3000 3000 E.S.P. (IN -H20): .6" .6" INDOOR FAN(HP /FLA): 1 HP 1 HP OUTDOOR FAN(FLA): 4.0 4.0 COMPRESSOR RLA/LRA: 16/91 16/91 COMB. FAN (FLA): .40 .40 MCA/MOCP 41.2/50 41.2/50 VOLTAGE: 208 208 PHASE: 3 3 WEIGHT (LBS): 1000 1000 REMARKS: (1) (1) NOTES: (1) WITH ECONOMIZER / POWER EXHAUST / CRANK CASE HEATER / COMPR. SHORT -CYCLE PROTECTION, ROOF CURB, RACK AND 2" FILTERS UNIT STANDARD SAFETY FEATURES / BELT DRIVE OPTION / HI /LO PRESSURE SWITCH / SMOKE DUCT DETECTOR IN RETURN AIR. MAKE -UP AIR UNIT SCHEDULE DESIGNATION: MAU -1 ZONE: KITCHEN MANUFACTURER: CAPTIVEAIRE MODEL: A2 -G15 DISCHARGE: DOWN C.F.M.: 3240 E.S.P. (IN -H20): .75" FAN HP: 1.5 HEATING INPUT (MBH): • N/A HEATING OUTPUT (MBH): N/A AFUE N/A VOLTAGE: 208 PHASE: 3 OPERATING WEIGHT (LBS): 382 REMARKS: (1)(2)(3)(4) EGG CRATE ALUMINUM (1) WITH MOTORIZED OUTSIDE AIR DAMPER INTERLOCKED WITH FAN MOTOR, 2" PLEATED FILTER AND RACK, MIN. 20 -GAUGE CONSTRUCTION - FULLY INSULATED UNIT ENCLOSURE, SPRING VIBRATION ISOLATION OR 2" THICK ISOLATION PAD, BELT DRIVE, DOWN DISCHARGE PLENUM, WEATHER HOOD. (2) SINGLE SPEED HIGH EFFICIENCY OPEN DRIP PROOF MOTOR, DISCONNECT AND MAGNETIC STARTER, SINGLE POINT CONNECTION. (3) INTERLOCK WITH KEF -1. COORDINATE AND VERIFY VOLTAGE WITH ELECTRICAL. INCLUDE 120V CONTROL TRANSFORMER AS REQUIRED. DIFFUSER & GRILLE SCHEDULE MARK APPLICATION MFR. / MODEL PATTERN MAT'L. FINISH BORDER ACCESSORIES REMARKS S -1 CEILING TITUS /300 -RL ADJ. STEEL 26 1 OPPOSED BLADE DAMPER DUCT MTD S -2 CEILING TITUS /MCD ADJ. STEEL 26 3 MODULE CORE LAY -IN T -BAR R -1 CEILING TITUS 50F EGG CRATE ALUMINUM 26 3 N/A LAY -IN T -BAR R -2 SIDEWALL TITUS 350ZRL HORIZONTAL ALUMINUM 26 1 BLADES W /0' DEFLECTION SIDEWALL RETURN R -3 CEILING TITUS 50F -NT EGG CRATE ALUMINUM 26 1 N/A DUCT MTD (2)(7) RTU -1 (1) SOURCE SPECIFIC FAN SHALL BE AMCA 210 OR HVI 916. (2) CONTROLLED BY LIGHT SWITCH. (3) CONTROLLED BY WALL SWITCH. (4) INTERLOCKED WITH DISHWASHER WITH MOUNTING HARDWARE AND SPEED CONTROLLER FOR AIR BALANCING. CONTROLLED VIA WALL SWITCH WITH LED INDICATOR. Dining Room 1078 7.5 65 0.06 15 - DEVICES SHALL BE TITUS OR APPROVED EQUAL. SEE SPECIFICATIONS - FLEXIBLE OR RIGID RUNOUT DUCT SIZE SHALL BE SAME SIZE AS DIFFUSER NECK UNLESS OTHERWISE SPECIFICALLY SHOWN ON DRAWINGS. - MAXIMUM NC FOR ANY DEVICE WITH SPECIFIED CFM AND WIDE -OPEN DAMPER SHALL BE NO GREATER THAN NC25. - CEILING MODULE SHALL BE 24X24 UNLESS OTHERWISE NOTED. - AIR PATTERN SHALL BE 4 -WAY UNLESS SHOWN OTHERWISE ON DRAWINGS. - DUCT MOUNTED AIR DEVICES SHALL BE INSTALLED AS SHOWN ON DETAIL. KITCHEN GREASE HOOD ROOFTOP EXHAUST FAN SCHEDULE DESIGNATION: KEF -1 ZONE: GREASE HOODS MANUFACTURER: CAPTIVEAIRE MODEL: NCA18FA DISCHARGE: UP CFM: 3600 TYPE: UPBLAST -BELT DRIVE E.S.P. (IN -H20): 1.30" FAN H.P.: 1.5 VOLTAGE: 208 PHASE: 3 WEIGHT (LBS): 155 REMARKS: (1)(2)(3)(4)(5)(6)(7) (') REFER TO HOOD DRAWINGS FOR ADDITIONAL INFORMATION. (2) PROVIDE ADDITIONAL MOTOR STARTERS & RELAYS FOR INTERLOCK TO MAKEUP AIR UNITS AND INTERLOCK WITH A HEAT DETECTOR(S) AS REQUIRED UNDER HOOD PER IMC 507.2.1.1. FALLOW MANUFACTURERS INSTRUCTIONS FOR START -UP AND INSTALLATION. (3) U.L. 762 LISTED EXHAUST FAN FOR GREASE KITCHEN HOOD PER NFPA #96 WITH GREASE TRAP, GREASE TRAP PILLOWS, DRAIN CONNECTION, BIRD GUARD, WEATHERPROOF DISCONNECT SWITCHES AND EXTRA LONG CABLES, HINGING KIT, FACTORY ROOF CURB. INSTALL DISCHARGE LIP AT MINIMUM 40" ABOVE ROOF PER NFPA #96 AND AS REQUIRED BY THE LOCAL JURISDICTIONS. (4) FACTORY ROOF CURB SHALL HAVE A VENTED CURB EXTENSION SECTION UNDER EXHAUST FAN TO VENT RATED SHAFT TO OUTSIDE. (5) COORDINATE EXACT LOCATION AND CONFIGURATION OF ROOF CURBS WITH STRUCTURAL FOR SUPPORT AND INSTALLATION. (VERIFY AT SITE) (6) VERIFY VOLTAGE WITH ELECTRICAL. COORDINATE WITH ELECTRICAL AND FIRE ALARM FOR EMERGENCY SHUT -DOWN REQUIREMENTS. (7) FAN SHALL BE U.L. LISTED FOR GREASE APPLICATIONS, INCLUDE CONTROL PACKAGE, SPEED CONTROLLER, SENSORS. CONTROL WIRING AND ALL REQUIRED ACCESSORIES FOR A COMPLETE INSTALLATION. CONSULT WITH MANUFACTURER FOR ALL REQUIRED ACCESSORIES. EXHAUST FAN SCHEDULE DESIGNATION: EF -1 KEF -2 QT /®S ZONE: TOILET RM DISHWASHER r, r- me MANUF.: BROAN CAPTIVEAIRE VD MODEL: L100 DU12HFA RIGID DUCT TYPE: CEILING DOWNBLAST FLEXIBLE DUCT DRIVE: DIRECT DIRECT CFM: 109 525 Occupancy Category E.S.P. (IN -H20): 0.125" 0.275" Area Outdoor Air Rate (cfm /sf) (Table 403.3) SONES: 0.9 -- Zone Outdoor Air Flow (Voz /(CFM) HP )FLA(: €1.1• .18 HP (2.0) Proposed Outdoor Air Intake Flow (CFM) VOLTAGE: 120 120 SQUARE CEILING GRILLE PHASE: 1 1 -CD WEIGHT: , :ii 41 SMOKE • DUCT DETECTOR REMARKS: (2)(4) (2)(7) RTU -1 (1) SOURCE SPECIFIC FAN SHALL BE AMCA 210 OR HVI 916. (2) CONTROLLED BY LIGHT SWITCH. (3) CONTROLLED BY WALL SWITCH. (4) INTERLOCKED WITH DISHWASHER WITH MOUNTING HARDWARE AND SPEED CONTROLLER FOR AIR BALANCING. CONTROLLED VIA WALL SWITCH WITH LED INDICATOR. HINGING KIT FOR FUTURE MAINTENANCE FLASH & COUNTER FLASH EXHAUST FAN 10' -0" (MIN.) OUTSIDE AIR INTAKES UP -BLAST TYPE DISCHARGE SHALL BE f 40" MINIMUM TO FAN DISCHARGE FROM ROOF. PROVIDE CURB HEIGHT ACCORDINGLY. 16 Ga. WELDED CARBON STEEL EXHAUST DUCT. INSIDE 1 -HR VENTED SHAFT, SEE ARCH'L. MIN. 6" - 12" MAX. FROM DUCT TO SHAFT. 3" AIR SPACE MIN. 0 CO 0 1 z 0 z VENTED CURB EXTENSION (4 SIDES) FOR VENTING THE RATED SHAFT. (SEE ARCH'L) ROOF 1.MIN. 18" (TYP) MINIMUM CLEARANCE TO COMBUSTIBLE MATERIAL PER I.M.C. WELDED GREASE DUCT • i GREASE TROUGH COOKING APPLIANCE -U 1 HR RATED SHAFT COORD. WITH ARCH'L U.L. CLASSIFIED BAFFLE TYPE GREASE FILTER STAINLESS STEEL FLASHING (18" AROUND HOOD -TYP) CEILING FIRE EXTINGUISHING HEAD PER NFPA 96 REQUIREMENTS BY KITCHEN CONTRACTOR. TYPE -1 EXHAUST HOOD BY OTHERS SCHEMATIC KITCHEN HOOD VENTILATION DETAIL A NO SCALE M1 TYPE 1 HOOD AND DUCTWORK GENERAL NOTES: A) COMPLETE INSTALLATION OF THE HOOD, FAN AND DUCTWORK SYSTEM SHALL BE PER THE I.M.C. - CHAPTER -5 AND N.F.P.A. #96 AS ADOPTED BY THE LOCAL JURISDICTIONS B) ALL JOINTS SHALL BE CONTINUOUSLY WELDED LIQUID TIGHT. C) ALL OFFSETS, ELBOWS AND TRANSITIONS SHALL BE SMOOTH - ROUND. D) HOOD AND DUCTWORK ABOVE CEILING (NON- VISIBLE) SHALL BE INSIDE A RATED ENCLOSURE (BY GENERAL CONTRACTOR) WITH AIR SPACE ALL AROUND THE DUCT AND HOOD VENTED TO THE OUTSIDE AT ROOF. CURB HEIGHT SHALL BE MINIMUM 18" ABOVE COMBUSTIBLE ROOF. • CLEANOUTS SHALL BE PROVIDED AT EACH CHANGE OF DIRECTION AND AS REQUIRED BY THE LOCAL JURISDICTIONS WITH ACCESS DOORS AT DUCT AND RATED ENCLOSURES. BOTTOM EDGE OF CLEANOUT SHALL NOT BE LESS THAN 2" ABOVE THE BOTTOM OF DUCT. CLEAN -OUT DOOR AND FRAME SHALL BE FABRICATED OF THE SAME GAUGE METAL AS THE DUCT. PROVIDE 1/8" THICK HIGH TEMPERATURE GASKET, APPROVED FOR USE ON KITCHEN EXHAUST DUCTS BETWEEN FRAME AND DUCT AND BETWEEN DOOR AND FRAME. ALL SEALANT MATERIALS SHALL BE APPROVED FOR HIGH TEMPERATURE INSTALLATION. F) THE COMPLEiti °.`SYSTEM SHALL BE AIR BALANCED AND THE FINAL REPORT SHALL BE SUBMITTED FOR APPROVAL. 0) SLOPE DUCTWORK TOWARD HOOD FOR GREASE DRAINAGE. H) INSTALL FLASH NG FROM THE BACK OF THE HOOD TO THE BACK WALL. WHERE APPLICABLE INSTALL FLASHING AT CEILING FROM HOOD TO 1 HR RATED SHAFT STARTING ABOVE CEILING. FLASHING SHALL BE SAME GAUGE AS HOOD. I) APPLIANCES UNDER HOOD, HOOD AND GREASE DUCTWORK SHALL HAVE A COMPLETE WET CHEMICAL FIRE SUPPRESSION SYSTEM EQUAL TO ANSUL R -102. COORDINATE WITH KITCHEN CONTRACTOR. COMPLETE INSTALLATION SHALL MEET N.F.P.A.,. U.L. AND LOCAL JURISDICTIONS' REQUIREMENTS. J) HOOD EXHAUST FANS SHALL BE HINGED OPEN FOR CLEANING WITH EXTRA LONG WIRING. K) ROOFTOP FAN DISCHARGE SHALL BE MINIMUM OF 40 INCHES APIEI1rr ECOPY _Minimum Outside Air Ventilation Schedule SYMBOL ABBREVIATION DESCRIPTION QT /®S T'STAT /SENSOR THERMOSTAT /SENSOR M4 r, r- me __ DUCTWORK W/ TURNING VANE AND FLEX CONN. VD VOLUME DAMPER 1 RIGID DUCT Ventilation Rate per 2009 SMC 403 (based on ASHRAE Std. 62.1 -2007) -- FLEXIBLE DUCT -- ROUND SPIN -IN WITH V.D. FD Equip. Tag Zone Occupancy Category Area (sf) People Outdoor Air Rate (dm/person) Table 403.3 Zone Population. Number of people in space.* Area Outdoor Air Rate (cfm /sf) (Table 403.3) Occupant p Density ( #/1000 sf) Breathing Zone Outdoor it Al Flow Vbz /(CFM) Zone Air Distribution Effectivene ss Ez (Table 403.3.1.2) Zone Outdoor Air Flow (Voz /(CFM) System Ventilation Efficiency Ev cV (Table 403.3.2.3.2 Min. Design Outdoor Air Intake Flow Vot /(CFM) Minimum Outdoor Air Intake Flow (CFM) Proposed Outdoor Air Intake Flow (CFM) SQUARE CEILING DIFFUSER CG SQUARE CEILING GRILLE CD CONDENSATE DRAIN LINE -CD , :ii -- SMOKE • DUCT DETECTOR A.F.F. ABOVE FINISHED FLOOR RTU -1 Dining Room Dining Room 1078 7.5 65 0.06 15 552.18 1.00 552.18 0.90 497 447 600 RTU -2 Office Office spaces 32 5.0 1 0.12 5 8.84 1.00 8.84 0.90 8 7 Kitchen Kitchens 1094 NA 6 NA NA NA NA NA NA NA 90 Total 544 600 * In some cases occupancy is less than maximums as allowed per 403.3 exception, in no case shall the occupancy be less than one half per Table 403.3. INSTRUCTION TO BIDDERS: 1) VERIFY WITH THE GENERAL CONTRACTOR FOR FIRE ALARM (SMOKE /FIRE DAMPERS, ETC.) PRIOR TO BIDDING. 2) INTERLOCK ALL AIR HANDLING EQUIPMENT WITH OUTSIDE AIR MOTORIZED DAMPER. 3) CONTRACTOR TO VERIFY ALL OWNER FURNISHED AND OWNER INSTALLED EQUIPMENT. 4) CONTRACTOR TO VERIFY AND COORDINATE ALL EQUIPMENT AND INSTALLATION BY ALL BIDDER DESIGN SUB - CONTRACTORS (I.E. COMM. SYSTEMS, SECURITY SYSTEMS, ETC.) E -' " . ... a1 :i:-1 TE PERMIT F': 2UIRED FOR: M�I ¶'Etectrrcat 3chanh rP►umbing *Ss Piping of Tukwila � aivrsroN REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. ENERGY CODE NOTES: 1) THERMOSTATS SHALL BE A 7 DAY PROGRAMMABLE TYPE WITH A 5 DEGREE DEADBAND AND AUTOMATIC SETBACK CONTROL PER 1 41 2.2 WASHINGTON STATE ENERGY CODE. 2) DAMPER SHALL MEET THE LEAKAGE RATE AND CONTROLS PER 1412.4.1 WSEC. 3) WHEN A HEAT PUMP IS INSTALLED THE EQUIPMENT SHALL MEET THE HEAT PUMP CONTROLS REQUIREMENT OF 1412.5 WSEC. 4) EACH AIR SUPPLY OUTLET, AIR OR WATER TERMINAL DEVICE SHALL HAVE A MEANS FOR BALANCING PER 1 41 2.7 5) SYSTEMS THAT SERVES ZONES WITH DIFFERENT USES AS DEFINED PER TABLE 15 -1 SHALL INCLUDE SETBACK AND SHUT -OFF FEATURES PER 1432.1 WSEC. 6) WHEN ECONOMIZER ARE REQUIRED THE ECONOMIZER SHALL BE CAPABLE OF MODULATING OUTSIDE AIR AND RETURN AIR DAMPERS OF THE 100% DESIGN SUPPLY AND ALSO SHALL PROVIDE A MEANS OF RELIEF DURING THE ECONOMIZER CYCLE. IN ADDITIONS THE CONTROLS SHALL ALLOW ECONOMIZER OPERATION WHEN MECHANICAL COOLING IS REQUIRED SIMULTANEOUSLY FOR PROVIDING PARTIAL COOLING PER 1413.1 AND 1413.3 WSEC. 7) HVAC EQUIPMENT SHALL MEET THE MINIMUM ENERGY EFFICIENCY RATINGS PER TABLE 14 -1, 14 -2 AND 14 -3 OF THE WSEC. 8) SUPPLY AND RETURN DUCTS IN UNCONDITIONED SPACES SHALL BE INSULATED TO MIN. R -8. ROOFTOP HVAC DUCTWORK SHALL HAVE A WEATHER BARRIER. DUCT INSULATION, TESTING AND SEALING SHALL BE PER 1414.1 AND 1 41 4.2 WSEC AND PER TABLE 14 -5 WSEC. PIPING INSULATION SHALL MEET THE REQUIREMENTS OF TABLE 14 -6 9) CONTRACTOR SHALL SUBMIT RECORD DRAWINGS AND OPERATING AND MAINTENANCE MANUALS PER 1416 WSEC. 10) CONTRACTOR SHALL PERFORM AND SUBMIT AN AIR BALANCE REPORT PER 1416.3.1 PER WSEC. 11) CONTRACTOR SHALL SUBMIT A COMMISSIONING REPORT AND DOCUMENTATION PER 1 41 6.4 PER WSEC AND PER COMMISSIONING COMPLIANCE CHECKLIST FIGURE 1 4B. 12) WHEN ELECTRIC WATER HEATER ARE PRESENT THEN R10 SHALL BE PROVIDED UNDER TANK PER 1441. 13) WHEN HOT WATER CIRCULATORS ARE PROVIDED THEN AUTOMATIC SHUT OFF CONTROLS OR HEAT TRACING SHALL BE PROVIDED PER 1443. REVIEWED FOR CODE COMPLIANCE APPROVED SEP 13 2011 tL VAL City of Tukwila JILDING DIVISION Permit �ca.1 �1 -DSO rewlew approval l3 subject to errors and (,r•;s °'SDI of construction documents does not ft: ...a: ion of any adopted code or pr 4 1 A ti e r :f'l rt`4l'.I't' 19/ I '1[ By Dix, I rze Receipt ,iraCiolowledged: RECEIVED 1 aty Of I Ykvil'a L P41419AMIa vW�vi SYMBOL ABBREVIATION DESCRIPTION QT /®S T'STAT /SENSOR THERMOSTAT /SENSOR M4 r, r- me __ DUCTWORK W/ TURNING VANE AND FLEX CONN. VD VOLUME DAMPER -- RIGID DUCT -- FLEXIBLE DUCT -- ROUND SPIN -IN WITH V.D. FD FIRE DAMPER - SFD SMOKE FIRE DAMPER • CFD CEILING RADIATION FIRE DAMPER CD ROUND CEILING DIFFUSER CG ROUND CEILING GRILLE i CD SQUARE CEILING DIFFUSER CG SQUARE CEILING GRILLE CD CONDENSATE DRAIN LINE -CD , :ii -- SMOKE • DUCT DETECTOR A.F.F. ABOVE FINISHED FLOOR Cern7CTION LT PLAN INDEX: MO1 GENERAL NOTES, SCHEDULES AND LEGEND M2 FLOOR PLAN - HVAC M3 ROOF PLAN - HVAC M4 SPECIFICATIONS - HVAC 080 s�o7ZO�, PERMITCEMTER ABOSSEIN ENGINEERING L.L.0 MECHANICAL - ELECTRICAL CIVIL - LEED - STRUCTURAL FIRE PROTECTION 2100 112TH AVE. NE BELLEVUE, WA 98004 OFFICE: (425) 462 -9441 FAX: (425) 462 -9451 EMAIL: CService@abossein.com WEBSITE: www.abossein.com C 4t E-4 GENERAL NOTES, SCHEDULES AND LEGEND TUKWILA, WASHINGTON 15037 TUKWILA INTERNATIONAL Revisions: PERMIT SET 6/14/11 ADDENDUM 1 6/22/11 2- ADDENDUM 2 6/28/11 /,PITY COMMENTS 8/29/11 Job No.: 211047 Date: 05/23/2011 MO1 (1 OF 4) LAYOUT NAME: La 1047 \211047_M02.dw REVDATE: FILE NAME: ROUND DUCT SPECIFICATIONS: EXPOSED ROUND DUCTWORK IN SALES AREA SHALL BE 24 GAUGE, SINGLE WALL GALVANIZED STEEL, SPIRAL LOCKSEAM. FITTINGS SHALL BE SINGLE WALL GALVANIZED STEEL, STANDING SEAM OR SOLID WELDED CONSTRUCTION. ELBOWS SHALL BE STANDING SEAM, GORED ELBOWS. GRILLE COLLARS SHALL BE ATTACHED TO THE DUCTWORK WITH POP RIVETS WITH A FINISHING FILLET OF ELASTOMER SEAL AT THE JUNCTION OF THE COLLAR • TO THE DUCT. DUCT -TO -DUCT JOINTS SHALL BE MADE WITH THE SPIRAL SEAM ROTATED SO THAT THE STANDING SEAM FORMS A CONTINUOUS HELICAL PATTERN ACROSS THE JOINT. ALL DUCTWORK AND FITTINGS SHALL BE MANUFACTURED IN ACCORDANCE WITH SMACNA'S HVAC DUCT CONSTRUCTION STANDARDS LATEST EDITION. ALL EXPOSED ROUND DUCTWORK AND FITTINGS IN THE SALES AREA SHALL BE CLEANED OF ALL OILS AND COATINGS PRIOR TO INSTALLATION AND PROVIDED WITH A MILL PHOSPHITIZED FINISH ( "PAINT GRIP ", "ZINC GRIP ", OR SIMILAR ETCH TREATMENT) TO ALLOW THE DUCTWORK TO BE PAINTED. SUPPORT FROM STRUCTURE WITH 1/4" THREADED ROD 1" WIDE 22 GAUGE HANGER BAND MAX 12' -0" SPACING NOTE: • MATERIALS AND INSTALLATION SHALL BE PER SMACNA STANDARDS 24 GAUGE, ROUND SPIRAL SEAM DUCT. SEE DWG'S. FOR SIZES. SHEET METAL BOOT TO MATCH DUCT SIDEWALL DIFFUSER. (S2) SEE SCHEDULE SEAL ALL AROUND WITH ELASTOMER GASKET EXPOSED SPIRAL SUPPLY DUCT DETAIL SCALE: NONE NOTE: EXHAUST TERMINATION AND PLUMBING VENT TERMINATIONS SHALL BE A MINIMUM OF 10 FEET FROM OUTSIDE AIR INTAKES (TYP.) LIGHTING NOTES: IRE 112 lIGHTING TIME IRRIGATION TIMER SRIf\,8 Ed ROOF WITH CAP 101 EXI T (` n ) W2 -1— 2466SQ NA . PONY WALL �- 6 "0 CELL LOCATED UNDER COVER NORTH SIDE OF BUILDING, ALL I XTERIOR BUILDING LIGHTS SHALL BE ON TIMER PROGRAMMED TO SHUT OFF AT DAYB'EAK AND ON AT DUSK, TIMER SHALL BE OVER`IDDEN BY PHOTOCELL CONTROL, cp?, SITE IGHTS WILL BE CONTROLLED BY OVERALL SHOP'ING CENTER TIMER & PHOTOCELL W2 40x14 .:EENED OPENING (FACING TOWARD CEILING) BOARD' W2 W /OPENINGS R4�1(��� t5 ARITION OOFfh BACK fir! --s1 0 2 W2 u � WON f F°11V IiViY 47,' BAfF HT, H. WAL /OPENIN VD S -1 W 360CFM 16X6 ■ 1 • W4 • (ON ROOF) CCHN WAUS !f I111�1u 11 5 7 r> ne_- I��I���, ,A�.,,:L!s��._.__ ICJ � coil: ... ., 1 . J z FLOOR PLAN-HVAC SCALE: 1/4" = 1' -0" NORTH KEYED NOTES: OA EXPOSED RIGID SHEET METAL DUCTWORK (AT DINING ROOM AREA ONLY). DUCTWORK SHALL BE FABRICATED AND SUPPORTED PER THE LATEST SMACNA "HVAC DUCT CONSTRUCTION STANDARDS" HANDBOOK. • SEE DETAIL THIS SHEET. DUCT MOUNTED DIFFUSERS WITH OPPOSED BLADE DAMPERS. (TYPICAL) © SADDLE TAP WITH SHEET METAL BOOT AND VOLUME DAMPER (TYPICAL) OD VERIFY & COORD. EXACT LOCATION AND ROUTING OF DUCTWORK WITH STRUC'L., CLG., LIGHTS AND AT SITE (TYP.). © MAXIMUM 6 FEET LONG FLEXIBLE DUCT (TYP.). 0 SEE AIR DIST. SCHEDULE, THIS SHT. (TYP.). © DUCTWORK ABOVE CLG. (TYP.) OH 7 -DAY PROGRAMMABLE THERMOSTAT © 66" AFF - WITH LOCKING COVER OR TAMPERPROOF FEATURES. O DUCT /SMOKE DETECTOR IN RETURN AIR DUCT. COORDINATE WITH ELECTRICAL AND FIRE ALARM. JO SPIN -IN VOLUME DAMPER (TYP.) O TRANSITION FROM SQUARE TO ROUND AT SUPPLY /RETURN OPENING. INCLUDE FLEXIBLE CONNECTION (VENTFABRICS OR EQUAL) (TYP.) © RECTANGULAR SUPPLY /RETURN DUCTWORK SHALL HAVE 1" SOUNDLINING . FOR THE FIRST 10 FEET AND DUCTWORK SHALL BE INSULATED WITH MINIMUM R -4 (TYP.) . ® TRANSITION FROM 10X34 OPENING AT HOOD COLLAR TO 18X18 16 GA. CARBON STEEL WELDED LIQUID TIGHT. GREASE DUCT INSIDE 1 -HR RATED SHAFT. SEE HOOD DWGS FOR ADDITIONAL INFORMATION. • 12"0 GALVANIZED SHEET METAL DISHWASHER DUCTWORK. TRANSITION AS REQUIRED TO BOTTOM OF FAN OPENING. M REVIEWEp OF R CODE COMPLIANCE APPROVED SEP 13 2011 ABOSSEIN 'ENGINEERING L.L.0 MECHANICAL - ELECTRICAL CIVIL - LEED - STRUCTURAL FIRE PROTECTION 2100 112TH AVE. NE BELLEVUE, WA 98004 OFFICE: (425) 462 -9441 FAX: (425) 462 -9451 EMAIL: CService@abossein.com WEBSITE: www.abossein.com 8 O L) TUKWILA, WASHINGTON 15037 TUKWILA INTERNATIONAL BLVD. City of Tukwila 'tJILDING DIVISION RECEIVED SEP 0 7 2011 PERMIT CENTER Revisions: PERMIT SET 6/14/11 A ADDENDUM 1 6/22/11 /s. ADDENDUM 26/28/11 ©CITY COMMENTS 8/29/11 Job No.: 211047 Date: 05/23/2011 M02 2 O 3) D: Wednesday, August 3 0 7 0 1047 \211047_M03.dwg LAYOUT NAME: N FILE NAME: NOTE: EXHAUST TERMINATION AND PLUMBING VENT TERMINATIONS SHALL BE A MINIMUM OF 10 FEET FROM OUTSIDE AIR INTAKES (TYP.) 5' l / / / / / ' \` - --r 8'; UP ROOF WIH ,CAP - -- - ■ / / / / / / / / / i MOTORIZED DAMPER CD 0 / '`` i f ` \\ I \\i \ 1 °'/ \ I \ I(___ /' ,�\ 1\ _ -- tI i ?1 �.1 0 FLOOR PLAN-HVAC SCALE: 1/4" = 1' -0" NORTH f KEYED NOTES: 0 DUCT /SMOKE DETECTOR IN RETURN AIR DUCT. COORDINATE WITH ELECTRICAL AND FIRE ALARM. © VERIFY (Sc. COORD. EXACT LOCATION AND ROUTING OF DUCTWORK WITH STRUC'L., CLG., LIGHTS AND AT SITE. TRANSITION TO UNIT OPENING AS REQUIRED WITH FLEXIBLE CONNECTION (TYP.). © OUTSIDE AIR INTAKES SHALL BE A MINIMUM OF 10 FEET FROM EXHAUST AND PLUMBING VENTS. (TYP.) 0 MOTORIZED DAMPER INTERLOCKED' WITH FAN MOTOR. © REMOTE WALK —IN COOLER CONDENSERS BY 'OTHERS (TYP.) TOP OF FAN DISCHARGE SHALL BE AT SAME ELEVATION AS ROOF PARAPET HEIGHT. ELEVATE FAN AS REQUIRED. (TYP.) 1 I 4) 0 REVIEWED FOR CODE COMPLIANCE APPROVED SEP 13 2011 City of Tukwila WILDING DIVISION RECEIVED SEP 0 7 2011 PERMIT CENTER ABOSSEIN ENGINEERING L.L.0 MECHANICAL - ELECTRICAL CIVIL - LEED - STRUCTURAL FIRE PROTECTION 2100 112TH AVE. NE BELLEVUE, WA 98004 OFFICE: (425) 462 -9441 FAX: (425) 462 -9451 EMAIL: CService @abossein.com WEBSITE: www.abossein.com 11II1 �JI./1/ 111 E 0 L) TUKWILA, WASHINGTON 15037 TUKWILA INTERNATIONAL BLVD. Revisions: PERMIT SET 6/14/11 /I\ ADDENDUM 1 6/22/11 ADDENDUM 2 6/28/11 3 CITY COMMENTS 8/29/11 _011/1111•11 , . Job No.: 211047 Date: 05/23/2011 M03 3OF 0 N N) 0 0 a) 0 0 L 0 J 0 T 0 J w z z 1- 0 0 0 N 0 N w z z w 1'� HVAC SPECIFICATIONS - DIVISION #23 PART 1.00 GENERAL 1.01 LOCAL CONDITIONS: VISIT AND INSPECT THE PREMISES TO ASCERTAIN THE EXISTING CONDITIONS BEFORE SUBMITTING A BID. NO EXTRA PAYMENT WILL BE ALLOWED FOR THE LACK OF KNOWLEDGE OF THESE CONDITIONS. 1.02 CODES: STRICTLY COMPLY WITH ALL APPLICABLE LOCAL, STATE, AND FEDERAL CODES AND REGULATIONS. IMC - MECHANICAL CODE IPC - PLUMBING CODE IFGC - FUEL GAS CODE 1.03 STANDARDS: THE FOLLOWING PUBLICATIONS (LATEST EDITION) FORM A PART OF THESE REQUIREMENTS TO THE EXTENT INDICATED BY THE REFERENCES THERETO: SHEET METAL AND AIR CONDITIONING CONTRACTOR NATIONAL ASSOCIATION (SMACNA) LOW VELOCITY DUCT MANUAL 1.04 PLANS AND SPECIFICATIONS: THE MECHANICAL DRAWINGS ARE DIAGRAMMATIC IN CHARACTER INTENDED TO COVEY THE SCOPE OF WORK AND INDICATE THE GENERAL ARRANGEMENT OF EQUIPMENT, DUCTS, PIPING, ETC., AND APPROXIMATE SIZES AND LOCATIONS OF EQUIPMENT AND OUTLETS. DETERMINE THE EXACT LOCATION OF THE ELEMENTS OF THE SYSTEM FROM THE STRUCTURE AND FROM THE EQUIPMENT, NOT FROM THE DRAWINGS. DO NOT SCALE DRAWINGS FOR MEASUREMENTS NOR USE AS SHOP DRAWINGS. 1.05 PROVIDE ALL ITEMS, EQUIPMENT, MATERIALS, OPERATIONS, OR METHODS LISTED, MENTIONED OR SCHEDULED ON THE DRAWINGS, AND /OR HEREIN INCLUDING ALL INCIDENTALS AND ACCESSORIES NECESSARY AND REQUIRED FOR INSTALLATION OR MOUNTING, OR NORMALLY SUPPLIED BY COMMON PRACTICE WHETHER SPECIFICALLY MENTIONED OR NOT, TO PROVIDE COMPLETE AND PROPERLY FUNCTIONING SYSTEMS. 1.06 BRING ANY NON- COMPLIANCES WITH ALL APPLICABLE LOCAL, STATE AND FEDERAL CODES AND REGULATIONS, CONFLICTS AND DISCREPANCIES TO THE ENGINEER'S ATTENTION BEFORE SUBMITTING BID. A CORRECT, COMPLETE AND EASILY MAINTAINED SYSTEM IS INTENDED. 1.07 THE CONTRACTOR'S BID WILL BE CONSTRUED AS AN AGREEMENT TO COMPLETE THE WORK WITHOUT ADDITIONAL COST TO THE OWNER. WHERE CONFLICTS BETWEEN PLANS AND SPECIFICATIONS OR CONFLICTING INFORMATION ON THE PLANS OCCURS, THE CONFLICTS SHALL BE REPORTED TO THE ARCHITECT PRIOR TO BIDDING. THE MORE COSTLY ALTERNATIVE SHALL BE INCLUDED IN THE BID PRICE. 1.08 MAKE NO CHANGES IN THE WORK SPECIFIED, UNLESS SUCH CHANGES ARE AUTHORIZED IN WRITING BY THE OWNER, ARCHITECT AND /OR ENGINEER. NO CHARGES - FOR EXTRA WORK WILL BE PAID UNLESS SUCH EXTRA WORK HAS BEEN AUTHORIZED AND THE AUTHORIZATION CONTAINS A STATEMENT OF THE WORK TO BE ACCOMPLISHED AND THE CHARGES TO BE MADE FOR THE WORK. 1.09 IT IS THE INTENT OF THESE SPECIFICATIONS TO PROVIDE A MECHANICAL SYSTEM COMPLETE, FULLY ADJUSTED, AND READY TO USE. 1.10 IT IS THE INTENTION OF THESE SPECIFICATIONS AND DRAWINGS TO CALL FOR FINISHED WORK, TESTED, AND READY FOR- OPERATION. WHEREVER THE WORK "PROVIDE" IS USED, IT SHALL MEAN "FURNISH AND INSTALL COMPLETE AND READY TO USE." MINOR DETAILS NOT USUALLY SHOWN OR SPECIFIED, BUT NECESSARY FOR THE PROPER INSTALLATION AND OPERATION, SHALL BE INCLUDED IN THE WORK, THE SAME AS IF HEREIN SPECIFIED OR SHOWN. 1.11 THE CONTRACTOR SHALL GIVE ALL NECESSARY NOTICES, OBTAIN ALL PERMITS AND PAY ALL GOVERNMENT SALES TAXES, FEES AND OTHER COSTS, INCLUDING UTILITY CONNECTIONS OR EXTENSIONS, IN CONNECTION WITH HIS WORK; FILE ALL NECESSARY PLANS, PREPARE ALL DOCUMENTS AND OBTAIN ALL NECESSARY APPROVALS OF ALL GOVERNMENTAL DEPARTMENTS HAVING JURISDICTION; OBTAIN ALL REQUIRED CERTIFICATES OF INSPECTION OF HIS WORK AND DELIVER SAME TO THE ARCHITECT BEFORE REQUEST FOR ACCEPTANCE AND FINAL PAYMENT FOR WORK. 1.12 THE CONTRACTOR SHALL INCLUDE IN THE WORK, WITHOUT EXTRA COST TO THE OWNER, ANY LABOR, MATERIALS, SERVICES, APPARATUS, DRAWINGS, IN ORDER TO COMPLY WITH ALL APPLICABLE LAWS, ORDINANCES, RULES AND REGULATIONS, WHETHER OR NOT SHOWN ON DRAWINGS AND /OR SPECIFIED. PART 2.00 PRODUCTS 2.01 MATERIALS AND EQUIPMENT SUBSTITUTIONS: THE BID PRICE SHALL BE BASED ON THE MATERIALS, EQUIPMENT AND /OR SERVICES AS SCHEDULED ON THE DRAWINGS AND /OR SPECIFIED HEREIN, AND /OR AS ACCEPTED PRIOR TO BIDDING. 2.02 REQUESTS FOR ACCEPTANCE OF ALTERNATIVES SHALL BE SUBMITTED TEN (10) DAYS PRIOR TO BID. ( ) 2.03 ACCEPTANCE OF ALTERNATE OR SUBSTITUTE EQUIPMENT IN NO WAY VOIDS MATERIAL OR PERFORMANCE REQUIREMENTS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PERFORMANCE OF ANY MATERIAL OR EQUIPMENT SUBSTITUTED FOR SPECIFIED ITEMS ACCEPTED BY THE ARCHITECT AND /OR ENGINEER BEFORE OR AFTER THE BID DATE. CONTRACTOR SHALL BE RESPONSIBLE FOR INCORPORATING ANY SUBSTITUTE EQUIPMENT IN THE SYSTEM DESIGN. 2.04 CONTRACTOR SHALL PAY FOR ALL EXTRA COSTS BY ANY TRADE FOR CHANGES NECESSITATED BY MATERIAL OR EQUIPMENT SUBSTITUTIONS REGARDLESS OF ACCEPTANCE WITHOUT FURTHER COST TO THE CLIENT. 2.05 REVIEW OF MATERIALS AND EQUIPMENT: WITHIN 30 DAYS OF CONTRACT AWARD, SUBMIT FIVE COPIES OF EACH 2.06 GENERAL MATERIALS AND EQUIPMENT: ALL MATERIAL AND EQUIPMENT SHALL BE NEW AND OF THE BEST OF CATALOG GRADE INDICATED AND /OR SPECIFIED AND SHALL BE FREE FROM ALL DEFECTS. 2.07 MATERIAL AND EQUIPMENT SPECIFIED HEREIN SHALL BE GUARANTEED BY THE MANUFACTURER TO PERFORM TO STANDARDS INDICATED OR INFERRED IN PUBLISHED LITERATURE OR CATALOG DATA. MANUFACTURER'S RECOMMENDATIONS SHALL BE CLOSELY FOLLOWED ON INSTALLATION. 2.08 REFRIGERANT PIPING: TYPE "L" OR TYPE "K" WITH BRAZED HIGH TEMPERATURE SOLDER JOINTS. PIPE SHALL BE CLEAN AND TESTED FOR LEAKS. INSULATE SUCTION PIPING WITH 1 INCH THICK FIBERGLASS WITH FRJ JACKET SEALED WATER TIGHT. COVER OUTDOOR INSULATION WITH ALUMINUM OR PLASTIC JACKET APPLIED IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. 2.09 ALL INSULATION SHALL HAVE A COMPOSITE (INSULATION, JACKET OR FACING, AND ADHESIVE) FIRE HAZARD RATING AS TESTED BY ASTM E -84, NFPA 255, OR UL 723, NOT TO EXCEED 25 FLAME SPREAD AND 50 SMOKE DEVELOPED. ACCESSORIES SUCH AS COATINGS, TAPES, AND ADHESIVES SHALL HAVE THE SAME COMPONENT RATINGS. ALL INSULATING MATERIALS OR THEIR CONTAINERS SHALL HAVE A LABEL INDICATING COMPLIANCE WITH THE ABOVE RATING. REFERENCE STANDARDS: NFPA D-255, A.S.T.M. E -84, UL -723, ASHRAE 90 -75 AND THE STATE ENERGY CODE. ACCEPTABLE MANUFACTURERS: CERTAINTEED, OWENS- CORNING, KNAUF AND MANVILLE. PART 3.00 EXECUTION 3.01 PERMITS AND INSPECTIONS: APPLY AND PAY FOR ALL PERMITS AND CERTIFICATES OF INSPECTION REQUIRED FOR THE WORK, AND AT COMPLETION, PRESENT THE OWNER WITH THE SIGNED CERTIFICATES OF FINAL INSPECTION. 3.02 UTILITIES: CHARGES BY UTILITY COMPANIES FOR PROVIDING SERVICES SHALL BE PAID BY OWNER AND WILL NOT BE A PART OF THIS CONTRACT. THE CONTRACTOR SHALL DO INSTALLATION WORK NORMALLY PROVIDED IN THIS CONTRACT. 3.03 PLACE AND ARRANGE EQUIPMENT, PIPING, DUCTS, CONTROLS, ETC., TO FIT THE SPACE AVAILABLE. INCLUDING ALL OFFSETS IN PIPING OR DUCTS, DUCT TRANSFORMATIONS, ETC. REQUIRED. 3.04 SUBMIT SHOP DRAWINGS FOR TEMPERATURE CONTROL SYSTEMS, MECHANICAL EQUIPMENT WIRING, MECHANICAL EQUIPMENT AND MATERIALS WHICH CANNOT BE ADEQUATELY DESCRIBED BY MANUFACTURER'S PRINTED SHEETS, AND FOR SUCH ADDITIONAL ITEMS AS THE ARCHITECT /ENGINEER MAY DIRECT. 3.05 CLEARLY MARK SUBMITTALS AS TO PLAN CODE, SPECIFIC ITEM PROPOSED, CATALOG NUMBERS, RECESS OPENINGS, DIMENSIONS, CAPACITIES, ELECTRICAL CHARACTERISTICS, ETC.. SUBMITTALS WHICH ARE INCOMPLETE WILL BE REJECTED. 3.06 THE ENGINEER'S CHECK SHALL BE GENERAL, AND DOES NOT RELIEVE THE CONTRACTOR OF FINAL RESPONSIBILITY OF COMPLIANCE TO THE INTENT OF THE PLANS AND SPECIFICATIONS. 3.07 SUPERVISION AND WORKMANSHIP: QUALIFIED SUPERVISION FOR EACH TRADE SHALL BE IN CHARGE OF THE WORK AT ALL TIMES AND SHALL BE ON THE JOB SITE WHENEVER WORK IN THAT TRADE IS BEING ACCOMPLISHED. 3.08 ALL WORK SHALL BE DONE IN A FIRST -CLASS MANNER BY WORKMEN SKILLED IN THE TRADE AFFECTED. 3.09 CLEANING PIPING, DUCTS, EQUIPMENT: THOROUGHLY CLEAN ALL DUCTS AND EQUIPMENT OF DIRT, CUTTINGS, AND OTHER FOREIGN SUBSTANCES. REMOVE FROM PREMISES ALL RUBBISH AND DEBRIS, LEAVING THE AREA CLEAN AND READY FOR USE. 3.10 EQUIPMENT START -UP: ADJUST ALL BELTS, OR OTHER DRIVES AND CHECK MOTOR ROTATIONS. 3.11 INSTALL TEMPORARY AIR FILTERS IN AIR HANDLING EQUIPMENT THAT IS BEING USED FOR HEATING OR VENTILATION DURING CONSTRUCTION. INSTALL A NEW SET OF THE SPECIFIED AIR FILTERS FOR THE EQUIPMENT AT THE COMPLETION OF THE JOB. 3.12 COMPLETION: OPERATE ALL MECHANICAL SYSTEMS, INCLUDING ALL EQUIPMENT FURNISHED UNDER THIS DIVISION FOR A PERIOD OF TIME NOT TO EXCEED 5 DAYS OR AS MAY BE REQUIRED AT THE DIRECTION ON THE ARCHITECT /ENGINEER TO PROVE THAT ALL COMPONENTS ARE PROPERLY OPERATING AND THAT THE COMPLETE INSTALLATION IS FUNCTIONING SMOCTHLY AND NOISELESSLY TO THE FULL EXTENT OF PLANS AND SPECIFICATIONS, ANY REBALANCING, READJUSTING OF SYSTEM ELEMENTS FOUND NECESSARY WHEN THE SYSTEMS ARE SUBJECT TO ACTUAL OPERATING CONDI TIONS SHALL BE DONE BY THE CONTRACTOR AT NO EXTRA COST TO THE OWNER. 3.13 OPERATING INSTRUCTIONS: SUBMIT 30 DAYS PRIOR TO COMPLETION OF THE PROJECT, FOUR (4) SETS OF OPERATING BROCHURES. EACH BROCHURE SHALL INCLUDE OPERATING INSTRUCTIONS, MAINTENANCE INSTRUCTIONS, INSTALLATION INSTRUCTIONS, PARTS LISTS AND WIRING DIAGRAMS FOR EACH ITEM OF MECHANICAL EQUIPMENT WITH MIXING OR MOVABLE PARTS. THE BROCHURE SHALL ALSO INCLUDE OPERATIONAL AND DIAGRAMS OF TEMPERATURE CONTROL SYSTEMS. 3.14 PROVIDE TYPEWRITTEN OPERATING INSTRUCTIONS IN THE BROCHURE COVERING EACH PIECE OF MOTORIZED MECHANICAL EQUIPMENT, GIVE NORMAL STARTING AND STOPPING PROCEDURES, ALONG WITH PROPER PARTIES TO CONTACT IN THE EVENT OF EMERGENCY, FAILURE OF CONTROLS OR EQUIPMENT. OUTLINE OF INSTRUCTIONS AS FOLLOWS: NORMAL STARTING, STOPPING AND EMERGENCY SHUT -DOWN OF EACH PIECE OF MOTORIZED EQUIPMENT. PROVIDE LUBRICATION INSTRUCTIONS FOR EACH MOTOR BEARING OR OPERABLE PIECE OF EQUIPMENT. GIVE FREQUENCY OF LUBRICATION, TYPE AND BRAND OF OIL OR GREASE. INCLUDE CALIBRATION, CLEANING AND ADJUSTMENT SCHEDULES AND PROCEDURES. INCLUDE COPIES OF MANUFACTURER'S LJTERATURE ON MAINTENANCE AND OPERATION OF EACH PIECE OF EQUIPMENT, INCLUDING INSTALLATION INSTRUCTIONS, DIAGRAMS, AND PARTS LISTS, IN EACH BROCHURE. 315 AS -BUILT DRAWINGS: SUBMIT AS -BUILT DRAWINGS AT COMPLETION OF WORK. WORK, 3.16 GUARANTEE: THE MECHANICAL SYSTEM SHALL BE LEFT IN PROPER WORKING ORDER. REPLACE ANY WORK MATERIAL OR EQUIPMENT PROVIDED UNDER THIS CONTRACT WHICH DEVELOPS DEFECTS WITHIN ONE (1) YEAR FROM DATE OF SUBSTANTIAL COMPLETION WITHOUT ADDITIONAL CHARGES. A NEW ONE (1) YEAR GUARANTEE ON THE AFFECTED ITEM OR ITEMS SHALL BE PROVIDED COMMENCING ON THE DATE OF THE APPROVED REPAIR OR REPLACEMENT. 3.17 MECHANICAL EQUIPMENT WIRING AND CONNECTIDNS: FURNISHED INSTALLED BY WIRED AND/OR ITEM BY OR MOUNTED BY CONNECTED BY EQUIPMENT MOTORS MC MC EC MOTOR CONTROLLERS, PUSHBUTTON STATIONS, PILOT LIGHTS, ETC. MC EC EC MULTI -SPEED SWITCHES LINE VOLTAGE THERMOSTATS MC EC EC DISCONNECT SWITCHES, (FUSED OR UNFUSED), HP RATED SWITCHES, THERMAL OVERLOAD SWITCHES, ETC. MC EC EC LOW VOLTAGE T THERMOSTATS, CONTROL RELAYS, TIME CLOCKS, CONTROL TRANSFORMER, CONTROL PANELS, PRESURESTATS, MOTOR VALVES, DAMPER MOTORS, SOLENOID VALVES, EP & PE SWITCHES, ETC. AND ALL INTERLOCK WIRING MC MC MC MC - MECHANICAL CONTRACT EC - ELECTRICAL CONTRACT ' THE MECHANICAL CONTRACTOR SHALL FURNISH ALL MAGNETIC STARTERS OR CONTACTORS. 3.18 ALL MANUAL OR AUTOMATIC CONTROL AND PROTECTIVE OR SIGNAL DEVICES REQUIRED BUT NOT INDICATED ON ELECTRICAL PLANS SHALL BE FURNISHED AND INSTALLED UNDER THIS DIVISION OF THE SPECIFICATIONS. THE WIRING INSTALLATION SHALL CONFORM TO ELECTRICAL DIVISION. 3.19 ALL WIRING CONNECTIONS TO CONTROLS ATTACHED TO DUCT WORK, OR MECHANICAL EQUIPMENT SHALL BE MADE WITH FLEXIBLE CONNECTIONS TO PREVENT VIBRATION. 3.20 COORDINATE WITH THE ELECTRICAL CONTRACTOR BEFORE ORDERING MOTORS AND /OR OTHER ELECTRICAL EQUIPMENT TO ASSURE ELECTRICAL EQUIPMENT BEING OF PROPER ELECTRICAL CHARACTERISTICS. 3.21 FURNISH PROPER NEMA TYPE ENCLOSURES FOR ALL STARTERS AND /OR CONTACTORS AS REQUIRED BY USAGE OR CODE. 3.22 PROVIDE HEAVY DUTY SPEED SELECTOR SWITCHES, THERMAL MAGNETIC SWITCHES, START STOP PUSH BUTTON STATIONS ETC. AS REQUIRED. 3.23 CUTTING AND PATCHING: CAREFULLY PERFORM ALL WORK WHERE CUTTING, CHANNELING, CHASING, OR DRILLING OF FLOORS, WALLS, PARTITIONS, CEILINGS OR OTHER SURFACES IS NECESSARY FOR PROPER INSTALLATION OR SUPPORT OF DUCTS, PIPINGS, OR OTHER MECHANICAL EQUIPMEN T. 3.24 ANY DAMAGE TO BUILDING, PIPING, EQUIPMENT, PLASTER, WOODWORK OR METAL WORK SHALL BE REPAIRED BY SKILLED MECHANICS OF TRADES INVOLVED, AT NO ADDITIONAL COST TO THE OWNER. 3.25 DO NOT CUT, CHANNEL, CHASE OR DRILL MASONRY OR TILE; OR CUT, DRILL OR WELD STRUCTURAL MEMBERS OF THE BUILDING, ETC., WITHOUT FIRST OBTAINING ARCHITECT'S PERMISSION, IF PERMISSION IS GRANTED, PERFORM THIS WORK IN A MANNER APPROVED BY THE ARCHITECT. 3.26 CAULKING & WATERPROOFING: CAULK AROUND ALL PIPES, ETC. TO PREVENT AIR AND MOISTURE LEAKAGE WITH COMPOUND APPROVED BY ARCHITECT /ENGINEER. 3.27 SEAL AROUND ALL PIPES AND DUCTS WITH FIREPROOF CAULKING OR GROUT WHERE THEY PASS THROUGH FLOORS, FIREWALLS, AND SHAFTS. 3.28 PROVIDE FLASHINGS WHERE ALL PIPES AND DUCTS PIERCE OUTSIDE WALLS OR ROOF AS NECESSARY TO PREVENT MOISTURE ENTRY. 3.29 INSERTS, SLEEVES & BLOCKOUTS: FURNISH AND INSTALL, PRIOR TO CONCRETE POURING OR OTHER CONSTRUCTION, INSERTS, SLEEVES, OR BLOCKOUTS IN WALLS, FLOOR SLABS, ROOFS AND PARTITIONS FOR PASSAGE OF ALL WORK INSTALLED UNDER THIS DIVISION. 3.30 PROVIDE GALVANIZED IRON AND STEEL PIPE SLEEVES FOR IRON PIPES. USE COPPER SLEEVES FOR COPPER PIPES. PROVIDE WOOD OR STEEL BLOCKOUTS FOR LARGE OPENINGS. SECURE ALL SUCH ITEMS FIRMLY IN POSITION. 3.31 VIBRATION - ABSORBING MOUNTINGS AND CONNECTIONS: ISOLATE EACH ITEM OF EQUIPMENT WITH MOVING PARTS FROM THE BUILDING STRUCTURE ALONG WITH ANY PIPING, CONDUITS, OR DUCTS ATTACHED THERETO. UNLESS OTHERWISE INDICATED, UNITS ISOLATING EQUIPMENT FROM STRUC TURE SHALL BE PROPERLY DESIGNED SPRING -TYPE ISOLATORS. 3.32 BELT DRIVE GUARDS: PROVIDE BELT DRIVE GUARDS FOR ALL EQUIPMENT AND SAFETY SCREENS ON EXPOSED FAN INLETS. 3.33 VALVES: NIBCO BALL VALVES OR EQUAL. 3.34 AIR CONDITIONING UNITS: PER EQUIPMENT SCHEDULE WITH CAPACITY AS INDICATED. UNIT SHALL BE AN AIR - COOLED CONDENSING UNIT, AIR HANDLING UNIT WITH DX -COILS OR HEAT PUMPS OR GAS FURNACE OR HOT WATER COILS, FILTER MIXIMG BOX AND VIBRATION ISOLATORS. TOTAL CAPACITY OF EACH UNIT SHALL BE AS SCHEDULED ON THE DRAWINGS. 3.35 CONTROLS - THE COOLING SYSTEM SHALL BE PROTECTED WITH HIGH PRESSURE STAT, LOW PRESSURE STATS, LOSS -OF- CHARGE PROTECTION, INDOOR COIL FREEZESTATS, CURRENT AND TEMPERATURE SENSITIVE OVERLOAD DEVICES. 3.36 PROVIDE PRODUCTS OF COMBUSTION DETECTOR IN SUPPLY AND RETURN AIR IN ALL UNITS 2000 CFM OR OVER TO SHUT DOWN UNIT ON ALARM CONDITION. 3.37 EXHAUST FANS: FANS SHALL MEET CAPACITIES SCHEDULED AND NOT EXCEED SOUND LIMITATIONS SPECIFIED. 3.38 GRILLES & REGISTERS: SCHEDULED ON DRAWINGS. TITUS OR EQUAL. 3.39 DUCT LINING: 1/2" THICKNESS, 3 PCF DENSITY, NEOPRENE COATED DUCT LINER MEETING FIRE HAZARD RATING REQUIREMENTS FOR INSULATION. INSTALL WITHIN MINIMUM 10' DUCT LENGTH FROM FANS. 3.40 DUCTWORK: SHEET METAL DUCTWORK SHALL BE CONSTRUCTED OF GALVANIZED STEEL. DUCTS SHALL CONFORM ACCURATELY TO THE DIMENSIONS INDICATED AND SHALL BE STRAIGHT AND SMOOTH ON THE INSIDE WITH JOINTS NEATLY FINISHED. DUCT CONSTRUCTION SHALL BE IN ACCORDANCE WITH SMACNA LOW PRESSURE DUCT MANUAL, 2" WG FOR SUPPLY & 1" WG FOR EXHAUST DUCTS. ELBOWS, FITTINGS AND BRANCH TAKE -OFFS SHALL BE DESIGNED, CONSTRUCTED AND INSTALLED AS RECOMMENDED IN SMACNA "DUCT CONSTRUCTION STANDARDS" WITH THE USE OF TURNING VANES OR RADIUS ELBOWS. FLEXIBLE RUNOUTS FROM BRANCHES, RISERS OR MAINS TO AIR TERMINAL UNITS, AND OUTLETS SHALL BE FACTORY- FABRICATED, CLASS I, VAPOR BARRIER INSULATED FLEXIBLE CONNECTORS COMPLYING WITH NFPA STANDARD NO. 90A AND UL 181. FLEXIBLE CONNECTORS SHALL NOT EXCEED 10' IN LENGTH. PRESSURE RATING SHALL BE 4" W.G. FLEXIBLE DUCT CONNECTIONS TO EQUIPMENT AND OTHER DUCTS SHALL BE MADE WITH DRAW BANDS. PROVIDE DAMPER IN RUN OUT, TO AIR OUTLETS. 3.41 HINGED DUCT ACCESS DOORS SHALL BE PROVIDED AT ALL AUTOMATIC DAMPERS, FIRE DAMPERS, AND OTHER APPARATUS REQUIRING SERVICE AND INSPECTION IN THE DUCT SYSTEM. DOORS SHALL BE 15 X 18 INCHES UNLESS OTHERWISE INDICATED. WHERE SIZE OF DUCT WILL NOT ACCOMMODATE THIS SIZE, THE DOOR SHALL BE MADE AS LARGE AS PRACTICAL. DOORS SHALL BE PROVIDED WITH AIRTIGHT GASKETS, GALVANIZED HINGES AND APPROVED BRASS FASTENERS. DOORS IN INSULATED DUCTS SHALL BE OF THE INSULATED TYPE. DOORS SHALL SO SWING THAT FAN PRESSURE OR SUCTION HOLD DOOR CLOSED. 3.42 PROVIDE NON- COMBUSTIBLE APPARATUS FLEXIBLE CONNECTIONS OF NOT LESS THAN 15 OUNCE WOVEN FABRIC APPROVED MATERIAL WHERE SHEET METAL DUCTS ARE CONNECTED TO FANS OR OTHER MOVING EQUIPMENT. THE FLEXIBLE CONNECTIONS SHALL BE SECURELY FASTENED. 3.43 DUCT LINER INSULATION: INSULATE INTERIOR SURFACES OF ALL HP -1, HP -2 SUPPLY DUCTS FROM AIR CONDITIONING UNIT SUPPLY FANS TO AIR OUTLETS AND INDICATED RETURN OR EXHAUST DUCTS WITH ACOUSTICAL MATERIAL. 3.44 APPLY AND SECURE INSULATION AS RECOMMENDED BY MANUFACTURER AND AS APPROVED. ANY LOOSENING OF INSULATION LINER WILL REQUIRE REMOVAL AND REINSTALLATION OF ALL DUCT WORK, AT NO EXTRA COST. 3.45 INCREASE INDICATED DUCT SIZES TO COMPENSATE FOR THICKNESS OF DUCT LINER INSULATION. SEALING: ALL TRANSVERSE JOINTS ON THE LOW PRESSURE SYSTEM SHALL BE SEALED WITH "HARDCAST" DUCT TAPE SYSTEM APPLIED IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS OR OTHER APPROVED SYSTEM. 3.46 IN LIEU OF RECTANGULAR LINED DUCT, RECTANGULAR DUCT INSULATED WITH 1" VAPOR BARRIER DUCT WRAP OR ROUND DUCT OF EQUIVALENT CROSS SECTIONAL AREA AND INSULATED WITH 1" VAPOR BARRIER INSULATION, MAY BE USED. ALL HP -1, HP -2 SUPPLY DUCTS SHALL BE LINED OR EXTERNALLY INSULATED. 3.47 GREASE DUCT FROM RANGE HOODS WHERE APPLICABLE TO EXHAUST FAN - 16 GAUGE BLACK IRON - WITH WELDED SEAMS AND JOINTS. WRAP DUCT WITH 2 LAYERS OF THERMAL CERAMICS FIREMASTER DUCT WRAP APPLIED AS RECOMMENDED BY THE MFR. TO MAKE A 2 HOUR RATED INSTALLATION. WRAP TO EXTEND FROM HOOD TO EXHAUST FAN. 3.48 DESCRIPTION: PERFORM TESTING AND BALANCING IN ACCORDANCE WITH THE PROCEDURE OF THE ASSOCIATED AIR BALANCE COUNCIL'S "NATIONAL STANDARDS FOR FIELD MEASUREMENTS AND INSTRUMENTATION TOTAL SYSTEM BALANCE." 3.49 USE ACCURATE INSTRUMENTS FOR BALANCING AIR SYSTEMS THAT HAVE BEEN CALIBRATED WITHIN 6 MONTHS PRIOR TO BALANCING. TYPES, SERIAL NUMBERS, AND DATE OF CALIBRATION OF ALL INSTRUMENTS SHALL BE LISTED IN THE FINAL AIR BALANCE REPORTS. 3.50 MAKE AIR QUANTITY MEASUREMENTS IN MAIN AND BRANCH DUCTS BY PITOT TUBE TRAVERSE OF THE ENTIRE CROSS SECTIONAL AREA OF THE DUCT. DUCTS HAVING VELOCITIES OF 1000 OR MORE FEET PER MINUTE SHALL BE MEASURED WITH INCLINED MANOMETERS (DRAFT GAUGE) OR MAGNEHELIC GAUGES. DUCTS HAVING VELOCITIES OF LESS THAN 1000 FT. PER MINUTE SHALL BE MEASURED WITH MICROMANOMETERS, HOOD GAUGES OR SIMILAR LOW PRESSURE INSTRUMENTS. OPENINGS IN DUCTS FOR PITOT TUBE INSERTION SHALL BE SEALED WITH SNAP -IN PLUGS AFTER AIR BALANCE IS COMPLETE. OUTLET AND INLET AIR QUANTITIES SHALL BE DETERMINED BY AN APPROVED METHOD. 3.51 TOTAL AIR QUANTITIES SHALL BE OBTAINED BY ADJUSTMENT OF FAN SPEEDS. THE BALANCING CONTRACTOR SHALL FURNISH AND INSTALL ANY REQUIRED FAN DRIVE CHANGES AS PART OF THIS CONTRACT. 3.52 VOLUME ADJUSTERS MAY BE USED TO BALANCE AIR QUANTITIES AT OUTLETS AND INLETS PROVIDING FINAL ADJUSTMENTS ARE MINOR AND DO NOT PRODUCE OBJECTIONABLE DRAFTS OR EXCESSIVE SOUND LEVELS. 3.53 CERTIFIED BALANCE REPORTS: THREE (3) COPIES OF THE AIR AND WATER BALANCE REPORT, CERTIFIED BY THE BALANCING FIRM, SHALL BE SUBMITTED TO THE ARCHITECT /ENGINEER SEVEN (7) DAYS PRIOR TO FINAL ACCEPTANCE OF THE PROJECT. THE REPORT SHALL INCLUDE ALL AIRAND WATER BALANCE DATE AND HEAT TRANSFER EQUIPMENT TEST DATA LISTED BELOW, AND OTHER DATA AS REQUIRED BY THE "NATIONAL STANDARD FOR FIELD MEASUREMENTS AND INSTRUMENTATION ". A.C. UNIT: CFM, STATIC PRESSURE, MOTOR HP, RPM, AND AMPS, PERCENT OF OUTSIDE AIR (OR CFM AS 3.54 APPLICABLE), FAN RPM, FAN BHP, INLET AND OUTLET DRY AND WET BULB TEMPERATURE, FAN DRIVE TYPE AND SIZE, WATER FLOW - 3.55 INDIVIDUAL OUTLET AND INLET TEST RESULTS: OUTLET AND INLET IDENTIFICATION (LOCATION AND NUMBER DESIGNATION). 3.56 FOLLOWING FINAL ACCEPTANCE OF THE SYSTEM BALANCE BY THE OWNER; THE CONTRACTOR SHALL PERMANENTLY MARK THE SETTINGS OF ALL VALVES, SPLITTERS, DAMPERS, AND OTHER ADJUSTMENT DEVICES SO THAT ADJUSTMENT CAN BE RESTORED IF DISTURBED AT ANY TIME. DEVICES SHALL NOT BE MARKED BEFORE FINAL ACCEPTANCE. NO NO STRUCTURAL MEMBERS SHALL BE CUT WITHOUT THE APPROVAL OF THE ARCHITECT, AND ALL SUCH CUTTING SHALL BE DONE IN A MANNER DIRECTED BY HIM. 3.58 PROVIDE THE BUILDING FLASHING AT ALL DUCT, PIPE, ETC. DESIGNED . AND INSTALLED THROUGH THE BUILDING WALLS AND ROOF. FLASHING SHALL BE DESIGNED AND INSTALLED PER SMACNA AND SHALL BE GUARANTEED WEATHER PROOF FOR THE DURATION OF THE GUARANTEE. 3.59 FIRE AND /OR SMOKE DAMPER 1. FURNISH AND INSTALL AT LOCATION SHOWN ON PLANS FIRE /SMOKE DAMPERS MEETING OR EXCEEDING THE FOLLOWING SPECIFICATIONS: FRAME SHALL BE A MINIMUM OF 16 GAUGE GALVANIZED STEEL FORMED INTO A STRUCTURAL HAT CHANNEL SHAPE WITH TABBED CORNERS FOR REINFORCEMENT. THE BLADES SHALL BE SINGLE SKIN 16 GAUGE MINIMUM GALVANIZED WITH THREE LONGITUDINAL GROOVES FOR REINFORCEMENT. BEARING SHALL BE STAINLESS STEEL SLEEVE TURNING IN AN EXTRUDED HOLE IN THE FRAME. BLADE EDGE SEALS SHALL BEW SILICON RUBBER MECHANICALLY LOCKED IN BLADE EDGE (ADHESIVE OR CLIP FASTENED SEALS ARE NOT ACCEPTABLE). JAMB SEALS SHALL BE STAINLESS STEEL FLEXIBLE METAL COMPRESSION TYPE. 2. EACH COMBINATION FIRE /SMOKE DAMPER SHALL BE RATED FOR 1.5 HOURS UNDER UL STANDARD 555 AND SHALL FURTHER BE CLASSIFIED BY UL AS A LEAKAGE RATED DAMPER FOR USE IN SMOKE CONTROL SYSTEMS UNDER UL 555S AND BEAR THE UL LABELS FOR BOTH UL 555 AND UL 555S. FIRE /SMOKE DAMPERS IN TUNNEL CORRIDOR SHALL BE UL LISTED FOR TUNNEL CORRIDOR CONSTRUCTION 3. IN ADDITION TO THE LEAKAGE RATING ALREADY SPECIFIED HEREIN, THE DAMPERS AND THEIR ACTUATORS SHALL BE QUALIFIED UNDER UL 555S TO MINIMUM ELEVATED TEMPERATURE OF 250 DEGREES (F). APPROPRIATE 120 VOLT ELECTRIC ACTUATORS SHALL BE INSTALLED BY THE DAMPER MANUFACTURER AT THE TIME OF DAMPER FABRICATION. DAMPER AND ACTUATOR SHALL BE INSTALLED AS S SINGLE ENTITY WHICH MEETS ALL APPLICABLE UL 555 AND UL 555S QUALIFICATIONS FOR BOTH DAMPERS ANDACTUATORS. ACTUATORS. DAMPERS MUST OPEN AND CLOSE WITHIN 15 SECONDS OF APPROPRIATE SIGNAL AND DAMPERS MUST CLOSE UPON LACK OF POWER. 4. FIRE ALARM CONTRACTOR SHALL PROVIDE ALL NECESSARY SWITCHES AND RELAYS ETC. TO INTERFACE DAMPER BUILDING FIRE ALARM AND CONTROL SYSTEM AS REQUIRED. 5. IN SYSTEMS. REQUIRING A SMOKE CONTROL SYSTEM, PROVIDE REMOTE SENSING OF DAMPER POSITION AND DAMPER OVERRIDE OF DAMPER CLOSURE TO PERMIT CONTROLLED OPERATION IN A DYNAMIC SMOKE MANAGEMENT SYSTEM. DEVICE SHALL BE RUSKIN MODEL TS 150 FIRE STAT OR APPROVED. 6. COMBINATION SMOKE /FIRE DAMPERS SHALL BE MANUFACTURED BY SAFEAIR, RUSKIN, GREENHECK, AIR BALANCE, NATIONAL CONTROLLED AIR AND PREFCO. E \GINEERI _! ®SSEI1 y I L. C L G MECHANICAL - ELECTRICAL CIVIL - LEED - STRUCTURAL FIRE PROTECTION 2100 112TH AVE. NE BELLEVUE, WA 98004 OFFICE: (425) 462 -9441 FAX: (425) 462 -9451 425 X: EMAIL: CService@abossein.com WEBSITE: www.abossein.com HIM '' �moss■mus° ` ~0} : 0 ,Ii: dF �' e ' � . i . ;. �. REVIEWED FOR GODS COMPLIANCE APPROVED �.. 3 2011 City of Tukwila UILDING DIVISION Revisions: PERMIT SET 6/14/11 / \ ADDENDUM 1 6/22/11 2 ADDENDUM 2 6/28/11 3 FY COMMENTS 8/29/11 ii n_,_ Job No.: 21 1047 RECEIVED Date: 05/23/201 1 JJJJ4. 4 OF 4 SEP 07 2011 til 1 i 0 8 it) PERMIT G NTER MEW a0 L E 0 to 10 ao 0 0 E 4) Q a 0 s 0 w 0 3- REVDATE: FILE NAME: J: \211047 \211047_PO1.dwg LAYOUT NAME: Layoutl PLU V1BING GE \ERAL \OTES 1. COMPLETE INSTALLATION OF THE MECHANICAL SYSTEM SHALL BE PER THE STATE OF WASHINGTON BUILDING, MECHANICAL ENERGY, FIRE, PLUMBING AND HEALTH CODES AND REGULATIONS AS ADOPTED BY LOCAL JURISDICTIONS. 2. ALL EQUIPMENT /FIXTURES SHALL BE THE CAPACITY AND TYPES AS SHOWN ON THE PLUMBING SCHEDULE AND SHALL BE THE LISTED MANUFACTURER AND MODEL NUMBER OR SHALL BE AN EQUAL APPROVED BY THE OWNER /ENGINEER. 3. THE CONTRACTOR SHALL SUBMIT MINIMUM OF SIX COPIES OF EQUIPMENT /FIXTURE SUBMITTALS FOR APPROVAL. 4. CONTRACTOR IS TO BRING UP THE DISCREPANCIES AND ITEMS WHICH ARE NOT SPECIFICALLY CALLED FOR OR SHOWN BUT ARE REQUIRED FOR A COMPLETE MECHANICAL SYSTEM AND AFFECT HIS CONTRACT PRIOR TO ENTERING AND SIGNING THE CONTRACT; AFTER AWARDING THE CONTRACT ALL SUCH ITEMS REQUIRED FOR A COMPLETE SYSTEM READY FOR THE OWNER'S BENEFICIAL USE SHALL BE FURNISHED AND INSTALLED INCLUDING ALL SUCH DISCREPANCY ITEMS MENTIONED ABOVE, AT NO ADDITIONAL COST TO THE OWNER AND PER LOCAL CODES. MANUFACTURER'S RECOMMENDATIONS AND APPLICABLE STANDARDS WITH THE ARCHITECT /ENGINEER'S APPROVAL. 5. ALL EQUIPMENT /FIXTURES SUPPLIED FOR THESE SPECIFICATIONS SHALL BE FREE FROM DEFECTS IN MATERIAL, WORKMANSHIP, AND TITLE, AND SHALL BE OF THE KIND AND QUALITY DESCRIBED HEREIN. IF IT APPEARS WITHIN ONE YEAR FROM DATE OF FINAL ACCEPTANCE THAT EQUIPMENT DOES NOT MEET THE WARRANTIES ABOVE, THE CONTRACTOR SHALL IMMEDIATELY CORRECT ANY DEFECT AND SHALL RESTORE THE SYSTEM TO THE ORIGINAL SATISFACTORY CONDITIONS AT HIS EXPENSE. THE FOREGOING WARRANTY IS EXCLUSIVE AND IN LIEU OF OTHER WARRANTIES, WHETHER WRITTEN, ORAL, IMPLIED OR STATUTORY. NO WARRANTY OF MERCHANT ABILITY OF FITNESS FOR PURPOSE SHALL APPLY. (THE WARRANTY SHALL START FROM THE TIME OF ARCHITECT /ENGINEER'S FINAL ACCEPTANCE.) 6. ENTIRE INSTALLATION OF ALL EQUIPMENT, FIXTURES, PIPING, PLUMBING AND RELATED ACCESSORIES SHALL BE PER BASIC OWNERS' STANDARDS. MECHANICAL CONTRACTOR IS TO FAMILIARIZE HIMSELF WITH THESE STANDARDS. 7. COORDINATE WITH THE STRUCTURAL ENGINEER TO PROVIDE STRUCTURAL SUPPORT FOR ALL EQUIPMENT. 8. COORDINATE THE CONSTRUCTION SCHEDULE WITH THE ARCHITECT AND PERFORM ALL REQUIRED WORK IN STRICT ACCORDANCE WITH THE OWNER'S SCHEDULE. 9. PLUMBING CONTRACTOR SHALL PAY FOR AND OBTAIN ALL REQUIRED PERMITS AND CERTIFICATES REQUIRED BY THE AUTHORITIES HAVING JURISDICTION. 10. ADJUST ALL EQUIPMENT AND PERFORM A COMPLETE WATER - BALANCING AND PUT ALL PLUMBING SYSTEMS IN OPERATION. 11. AIR - CONDITIONING UNIT COIL WITHOUT INTERNAL TRAP SHALL HAVE A P -TRAP (3" MIN. SEAL) FOR THE CONDENSATE PAN. DISCHARGE CONDENSATE DRAIN TO ROOF DRAIN. 12. PLUMBING CONTRACTOR SHALL VISIT THE SITE TO DETERMINE THE EXACT IMPACT OF THE NEW CONSTRUCTION FOR THE PLUMBING SYSTEM AND SHALL INCLUDE IN HIS BID ALL THE WORK WHICH MIGHT NOT BE SPECIFICALLY MENTIONED BUT ARE REQUIRED FOR A COMPLETE PLUMBING SYSTEM READY FOR OWNER'S BENEFICIAL USE. 13. COLD WATER LINES WITH OVER 70 -80 PSIG PRESSURES REQUIRE PRESSURE REDUCING VALVE AND STRAINER. 14. SCOPE OF WORK: THE CONTRACTOR SHALL INCLUDE IN HIS BID ALL THE COST RELATED TO INSTALLING NEW PIPING TO ALL NEW FIXTURES AS SHOWN AND AS REQUIRED BY THE UNIFORM PLUMBING CODE AND THE LOCAL JURISDICTIONS. ALL PLUMBING SYSTEM (PIPING, FIXTURES, EQUIPMENT, ETC.) INSIDE THE BUILDING SHALL BE NEW AND CONNECT TO NEW SANITARY AND NEW WATER PIPES OUTSIDE THE BUILDING. THE CONTRACTOR SHALL INCLUDE IN HIS BID ALL THE COST RELATED TO INVESTIGATING THE ROUTING OF SITE UTILITY PIPES IN ORDER TO MAKE NEW CONNECTIONS FOR THE NEW FIXTURES. (THE PIPE ROUTING AND CONNECTIONS MAY NOT BE SPECIFICALLY SHOWN ON THE DRAWINGS) THE CONTRACTOR SHALL INCLUDE IN HIS BID ALL THE COSTS REQUIRED FOR ALL THE PIPING TO MEET THE PIPE SIZES PER THE UNIFORM PLUMBING CODES TABLES -6 -4 & 7 -5. 15. SEE ARCHITECTURAL DRAWINGS AND SPECIFICATIONS FOR ADDITIONAL SCOPE OF WORK, INSTRUCTION TO BIDDERS AND EXACT LOCATION OF ALL FIXTURES. 16. PLUMBING CONTRACTOR SHALL INSTALL ALL HOT AND COLD WATER PIPING WITHIN THE HEATED AREAS FOR FREEZE PROTECTION. 17. COORDINATE EXACT LOCATION OF ALL EQUIPMENT, FIXTURES, PIPING, ETC. AND PENETRATIONS WITH THE ARCHITECTURAL STRUCTURAL AND AT SITE. 18. ALL APPLICABLE CODES AND LOCAL JURISDICTION REGULATIONS SHALL SUPERSEDE THE CONSTRUCTION DOCUMENTS IF THEY ARE MORE STRINGENT. 19. INSTALL ALL TRAP ARMS SUCH THAT THE MAXIMUM LENGTH WILL NOT EXCEED THE CODE REQUIREMENTS. 20. ALL FIXTURES REQUIRING PLUMBING SHALL BE CONNECTED TO BUILDING WASTE, VENT, COLD WATER AND HOT WATER SYSTEM AS REQUIRED BY THE CODES. 21. INSTALL CLEANOUTS PER THE 2009 UPC - SECTION 707 AND AS REQUIRED BY LOCAL JURISDICTIONS. 22. PIPE MATERIAL: COLD WATER & HOT WATER COPPER "L" (ABOVE GROUND)(LEAD FREE) COLD WATER & HOT WATER COPPER "K "(UNDERGROUND)(LEAD FREE) WASTE AND VENT CAST IRON, DWV COPPER, ABS. NOTE: JOINTS AND METHOD OF CONNECTIONS SHALL BE PER THE 2003 UPC - CHAPTER #14, ASTM STANDARDS AND MANUFACTURERS RECOMMENDATIONS FOR EACH PIPE TYPE AND APPLICATIONS. 23. PIPE INSULATION: . COLD WATER - 1/2" INSULATION WITH VAPOR BARRIER JACKETS. HOT WATER - 1" INSULATION FOR ALL PIPING UP TO 2" DIAMETER. UNDERGROUND PIPING WITH 1/2" CLOSED CELL FOAM INSULATION. 24. PIPE HANGERS AND SUPPORTS: PIPE HANGERS AND SUPPORTS SHALL BE IN STRICT ACCORDANCE WITH THE 2003 UPC - SECTION -314 AND PIPE MANUFACTURERS RECOMMENDATIONS. ALL PIPES SHALL BE SEISMICALLY RESTRAINED PER LATEST EDITION OF S.M.A.C.N.A. SEISMIC RESTRAINT MANUAL AND AS REQUIRED BY LOCAL JURISDICTION. 25. THE CONTRACTOR SHALL INCLUDE ALL EXCAVATION AND BACKFILLING REQUIRED FOR UNDERGROUND WORK IN HIS BID UNLESS OTHER ARRANGEMENTS ARE MADE WITH THE GENERAL CONTRACTOR PRIOR TO BIDDING. (COORDINATE WITH SITE /CIVIL ENGINEER). 26. DOMESTIC HOT WATER SYSTEM SHALL BE SET FOR 120'F OR AS REQUIRED BY LOCAL JRSD. 27. ALL WATER LINES SHALL BE STERILIZED IN ACCORDANCE WITH THE A.W.W.A. STANDARDS AND LOCAL REGULATIONS. 28. WATER SUPPLY LINE TO AIR /WATER STATION SHALL HAVE BACK FLOW PREVENTIONS AS REQUIRED BY THE JURISDICTIONS. 29. WATER HEATER RELIEF SHALL BE PIPED TO OUTSIDE. 30. ALL MATERIALS USED SHALL BE NEW AND BEAR U.L. LABEL WHEN REQUIRED. 31. FINAL AS BUILT DRAWINGS SHALL BE SUBMITTED TO ENGINEER /OWNER. 32. ALL OPENINGS AND PENETRATIONS THROUGH ROOF AND /OR WALLS SHALL BE PROPERLY SEALED, WEATHERTIGHT, AND AESTHETICALLY. ACCEPTABLE. 33. ALL CUTTING AND PATCHING REQUIRED FOR INSTALLATION OF NEW EQUIPMENT, FIXTURES AND PIPING TO BE BY CONTRACTOR. 34. INSTALL AIR CHAMBERS BEHIND EACH OUTLET OR WADE - SHOKSTOPS FOR EACH FIXTURE GROUP FOR WATER HAMMER ARRESTORS. GE \ERAL SPECIFICATIO \S A. B. C. D. E. F. G. H. J. K. L. M. N. IT IS THE INTENT OF THESE SPECIFICATIONS TO PROVIDE A MECHANICAL SYSTEM COMPLETE, FULLY ADJUSTED, AND READY TO USE. INSPECTION: PRIOR TO ALL WORK OF THIS DOCUMENT, CAREFULLY INSPECT THE INSTALLED WORK OF ALL OTHER TRADES AND VERIFY THAT ALL SUCH WORK IS COMPLETE TO THE POINT WHERE THIS INSTALLATION MAY PROPERLY COMMENCE. VERIFY THAT THE WORK MAY BE COMPLETED IN STRICT ACCORDANCE WITH ALL PERTINENT CODES AND REGULATIONS, THE APPROVED SHOP DRAWINGS, AND THE MANUFACTURERS' RECOMMENDATIONS. DISCREPANCIES: IN THE EVENT OF DISCREPANCY, IMMEDIATELY NOTIFY THE ARCHITECT /ENGINEER. DO NOT PROCEED IN AREAS OF DISCREPANCY UNTIL ALL SUCH DISCREPANCIES HAVE BEEN FULLY RESOLVED. INSPECTION: CHECK EACH PIECE OF EQUIPMENT IN THE SYSTEM FOR DEFECTS, VERIFYING THAT ALL PARTS ARE PROPERLY FURNISHED AND INSTALLED, THAT ALL ITEMS FUNCTION PROPERLY, AND THAT ALL ADJUSTMENTS HAVE BEEN MADE. GENERAL: DO NOT ALLOW OR CAUSE ANY OF THE WORK OF THIS SECTION TO BE COVERED UP OR ENCLOSED UNTIL IT HAS BEEN INSPECTED, VIEWED AND ACCEPTED BY THE LANDLORD /ARCHITECT/ ENGINEER AND BY ALL OTHER AUTHORITIES HAVING JURISDICTIONS. DO ALL THINGS NECESSARY TO COOPERATE WITH OTHER TRADES IN ORDER THAT ALL SYSTEMS IN THE WORK MAY BE INSTALLED IN THE BEST ARRANGEMENTS. COORDINATE AS REQUIRED WITH ALL OTHER TRADES TO SHARE SPACE IN COMMON AREAS AND TO PROVIDE THE MAXIMUM OF ACCESS TO EACH SYSTEM. IT IS THE INTENT OF THESE SPECIFICATIONS THAT ALL WORK, INCLUDING THE INSIDE OF EQUIPMENT, FIXTURES, PIPING, DUCTWORK, ETC. BE LEFT IN A CLEAN CONDITION. ALL CONSTRUCTION DIRT SHALL BE REMOVED FROM MATERIAL SITE AND EQUIPMENT. IT IS THE INTENTION OF THESE SPECIFICATIONS AND DRAWINGS TO CALL FOR FINISHED WORK, TESTED, AND READY FOR OPERATION. WHEREVER THE WORK "PROVIDE" IS USED, IT SHALL MEAN "FURNISH AND INSTALL COMPLETE AND READY TO USE." MINOR DETAILS NOT USUALLY SHOWN OR SPECIFIED, BUT. NECESSARY FOR THE PROPER INSTALLATION AND OPERATION, SHALL BE INCLUDED IN THE WORK, THE SAME AS IF HEREIN SPECIFIED OR SHOWN. THE CONTRACTOR SHALL GIVE ALL NECESSARY NOTICES, OBTAIN ALL PERMITS AND PAY ALL GOVERNMENT SALES TAXES, FEES AND OTHER COSTS, INCLUDING UTILITY CONNECTIONS OR EXTENSIONS, IN CONNECTION WITH HIS WORK; FILE ALL NECESSARY PLANS, PREPARE ALL DOCUMENTS AND OBTAIN ALL NECESSARY APPROVALS OF ALL GOVERNMENTAL DEPARTMENTS HAVING JURISDICTION; OBTAIN ALL REQUIRED CERTIFICATES OF INSPECTION OF HIS WORK AND DELIVER SAME TO THE ARCHITECT BEFORE REQUEST FOR ACCEPTANCE AND FINAL PAYMENT FOR WORK. THE CONTRACTOR SHALL INCLUDE IN THE WORK, WITHOUT EXTRA COST TO THE OWNER, ANY LABOR, MATERIALS, SERVICES, APPARATUS, DRAWINGS, IN ORDER TO COMPLY WITH ALL APPLICABLE LAWS, ORDINANCES, RULES AND REGULATIONS, WHETHER OR NOT SHOWN ON DRAWINGS AND /OR SPECIFIED. SURVEYS AND MEASUREMENTS: THE CONTRACTOR SHALL BASE ALL MEASUREMENTS, BOTH HORIZONTAL AND VERTICAL, FROM ESTABLISHED BENCH MARKS. ALL WORK SHALL AGREE WITH THESE ESTABLISHED LINES AND LEVELS. VERIFY ALL MEASUREMENTS AT SITE AND CHECK THE CORRECTNESS OF SAME AS RELATED TO THE WORK. DRAWINGS: DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS AND WORK INCLUDED IN THE CONTRACT. DRAWINGS ARE NOT TO BE SCALED. THE ARCHITECTURAL DRAWINGS AND DETAILS SHALL BE EXAMINED FOR EXACT LOCATION OF FIXTURES AND EQUIPMENT. WHERE THEY ARE NOT DEFINITELY LOCATED, THIS INFORMATION SHALL BE OBTAINED FROM THE ARCHITECT. PROTECTION: THE CONTRACTOR SHALL BE RESPONSIBLE FOR WORK AND EQUIPMENT UNTIL FINALLY INSPECTED, TESTED, AND ACCEPTED; HE SHALL PROTECT WORK AGAINST THEFT, INJURY OR DAMAGE; AND SHALL CAREFULLY STORE MATERIAL AND EQUIPMENT RECEIVED ON SITE WHICH ARE NOT IMMEDIATELY INSTALLED. HE SHALL CLOSE OPEN ENDS OF WORK WITH TEMPORARY COVERS OF PLUGS DURING STORAGE AND CONSTRUCTION TO PREVENT ENTRY OF OBSTRUCTING MATERIAL. THE CONTRACTOR SHALL FURNISH ALL SCAFFOLDING, RIGGING, HOISTING, AND SERVICES NECESSARY FOR ERECTION AND INSTALLATION OF THE MECHANICAL SYSTEM. 0. CONTRACTOR SHALL LOCATE ALL EQUIPMENT WHICH MUST BE SERVICED, OPERATED, OR MAINTAINED IN FULLY ACCESSIBLE POSITIONS. P. Q. R. S. T. U. V. THIS CONTRACTOR SHALL PROVIDE ALL CUTTING AND PATCHING NECESSARY TO INSTALL THE WORK SPECIFIED IN THIS SECTION. PATCHING SHALL MATCH ADJACENT SURFACES. NO STRUCTURAL MEMBERS SHALL BE CUT WITHOUT THE APPROVAL OF THE ARCHITECT, AND ALL SUCH CUTTING SHALL BE DONE IN A MANNER DIRECTED BY HIM. THIS CONTRACTOR SHALL PROVIDE AND LOCATE ALL SLEEVES AND INSERTS REQUIRED BEFORE THE FLOORS AND WALLS ARE BUILT, OR SHALL BE RESPONSIBLE FOR THE COST OF CUTTING AND PATCHING REQUIRED FOR PIPES WHERE SLEEVES AND INSERTS WERE NOT INSTALLED, OR WHERE INCORRECTLY LOCATED. THE CONTRACTOR SHALL DO ALL DRILLING REQUIRED FOR THE INSTALLATION OF HIS HANGERS. SLEEVES SHALL BE PROVIDED FOR ALL MECHANICAL PIPING PASSING THROUGH CONCRETE FLOOR SLABS AND CONCRETE, MASONRY, TILE AND GYPSUM WALL CONSTRUCTION. ALL INSULATION SHALL HAVE A COMPOSITE (INSULATION, JACKET OR FACING, AND ADHESIVE) FIRE HAZARD RATING AS TESTED BY ASTM E -84, NFPA 255, OR UL 723, NOT TO EXCEED 25 FLAME SPREAD & 50 SMOKE DEVELOPED. ACCESSORIES SUCH AS COATINGS, TAPES, AND ADHESIVES SHALL HAVE THE SAME COMPONENT RATINGS. ALL INSULATING MATERIALS OR THEIR CONTAINERS SHALL HAVE A LABEL INDICATING COMPLIANCE WITH THE ABOVE RATING. REFERENCE STANDARDS: NFPA D -255, A.S.T.M. E -84, UL -723, ASHRAE 90 -75 AND THE STATE ENERGY CODE. ACCEPTABLE MANUFACTURERS: CERTAINTEED, OWENS- CORNING, KNAUF AND MANVILLE. THE CONTRACTOR SHALL PROVIDE THE OWNER WITH A COMPLETE OPERATING AND MAINTENANCE MANUAL AND ONE SET OF MYLAR REPRODUCIBLES SHOWING ALL AS -BUILT CONDITIONS. THE MANUALS SHALL INCLUDE ALL MANUFACTURER'S SPECIFICATIONS, OPERATION, MAINTENANCE, INSTRUCTIONS, WARRANTY, LOCAL SOURCE OF SUPPLY FOR SPARE PARTS AND SERVICES, ETC. PROVIDE WEATHER -PROOF FLASHING AT ALL DUCT, PIPE, ETC. MECHANICAL PENETRATIONS THROUGH THE BUILDING WALLS AND ROOF. FLASHING SHALL BE DESIGNED AND INSTALLED PER SMACNA AND SHALL BE GUARANTEED WEATHER PROOF FOR THE DURATION OF THE GUARANTEE. COVER FINISHED FLOOR CLEANOUT PLUG AND BODY. SEE SPECIFICATIONS FLOW -. ADJUSTING COLLA RISER CONCRETE ENCASEMENT GRADE CLEA\IOUT DETAIL SCALE: NONE FLOW -NI- PLUMBING FIXTURE CON \ECTIO\ SCHEDULE FIXTURE DESCRIPTION CW HW P -TRAP W VENT NOTES P1 WATER CLOSET 1/2" - 3" 3" 2" 2 P2 LAVATORY 1 /2" 1 /2" 1 -1 /4" 1 -1 /2" 1 -1 /2" P3 URINAL 3/4" - - 2" 1 -1/2" GREASE INTERCEPTOR CAPACITY = 750 GALLON, PER THE 2009 UPC CHAPTER 10, TABLE 10 -3 (GRAVITY GREASE INTERCEPTOR) 41 PREP -SINK _ - - 1 -1/2 - VENT PIPE aPREP -SINK FAUCET 1 /2" 1 /2" - WASTE PIPIE - P1 58 MOP /HAND SINK - - 2" 2" 1 -1/2" 59 MOP /HAND SINK FAUCET 1/2" 1/2" - - • - GV 64 PRE -RINSE SINK - - _ 1 -1/2" - INDIRECT DRAIN PIPE TO FLOOR SINK 66 PRE -RINSE SINK FAUCET 1 /2" 1 /2" - - - © C.)7 QUICK DRAIN - - - 1" - INDIRECT DRAIN PIPE TO FLOOR SINK 69 DISHWASHER - 1/2" - 2" - INDIRECT DRAIN PIPE TO FLOOR SINK 70 2- COMPARTMENT SINK - - - 2" - INDIRECT DRAIN PIPE TO FLOOR SINK WCO 2- COMPARTMENT STAINLESS FAUCET 1/2" 1/2" - - - 90. POT FILL FAUCET 3/4" - - - - 3/4" PIPE SIZE 94 HAND SINK - - 1 -1/2" 2" 1 -1/2" CHECK VALVE 95 HAND SINK FAUCET 1/2" 1/2" - - - lit COFFEE BREWER 1/2" - - - - D1 FLOOR DRAIN - - 2" 2" 1 -1/2" PRESSURE CI)2 FLOOR SINK - - 2" 2" 1 -1 /2" O4 ICE DISPENSER 1 /2" - - 1" - INDIRECT DRAIN PIPE TO FLOOR SINK SODA. MACHINE 1/2" - - 1 -1/2" - INDIRECT DRAIN PIPE TO FLOOR SINK NOTES: (1) ALL FIXTURES IN THIS SCHEDULE ARE PROVIDED BY OWNER INSTALLED BY PLUMBING CONTRACTOR. PLUMBING CONTRACTOR SHALL PROVIDE ALL P- TRAPS, STOP VALVES AND RISERS TO PROVIDE A OPERATING FIXTURE READY FOR USE. P -TRAPS SHALL BE CHROME PLATED CAST BRASS, STOP VALVES SHALL BE METAL CHROME PLATED, RISER SHALL BE FLEXIBLE METAL. (2) ALL FLOOR DRAINS WITHOUT RECEIVING CONTINUOUS WATER SHALL HAVE TRAP PRIMERS. GREASE INTERCEPTOR SIZI \G FIXTURE DESCRIPTION #FIXF FU TOUAL NOTES D1 FLOOR DRAIN 1 2 2 NAVIEN MODEL # CC -240A, GAS FIRED WATER HEATER, 199 MBH INPUT 195.2 MBH OUTPUT © 98% COMBUSTION EFFICIENNCY PROVIDED BY OWNER INSTALLED BY PLUMBING CONTRACTOR 42 PREP -SINK 1 2 2 COLD WATER PIPIE CI) PRE -RINSE SINK 1 2 2 42 3- COMPARTMENT SINK 1 6 6 TOTAL FU'S 12 GREASE INTERCEPTOR CAPACITY = 750 GALLON, PER THE 2009 UPC CHAPTER 10, TABLE 10 -3 (GRAVITY GREASE INTERCEPTOR) 0.5 GPM FLOW CONTROL (MUST BE INSTALLED) ON HEATER OUTLET SECURE TO WALL WITH TOGGLE BOLTS ELECTRICAL CONNECTION WITH ACCESS DOOR NOTE: MOP SINK PIPING SIMILAR NOTE: INSTALL WATER HEATER PER AND PER THE LOCAL CODES, INSULATED PIPES WITH HANDI -LAV -GUARD 3 -WAY STOP _ 1/2" COLD WATER NPT 1/2" TO LAVATORY INSTANT -FLOW HEATER 3/8" TO HEATER 3/8" FPT INLET & OUTLET THE MANUFACTURER'S RECOMMENDATIONS UNIT MUST BE HARD WIRED. INSTA\T FLOW WATER HEATER 2 SCALE: NONE (MODEL SR -15L) P01 PLUMBING LEGEND (Sc ABBREVIATIO \S SYMBOL ABBR DESCRIPTION SYMBOL ABBR DESCRIPTION AM GREASE INTERCEPTOR - GREAT BASIN # GB -250, 250 GALLON CAPACITY PROVIDED BY OWNER INSTALLED BY PLUMBING CONTRACTOR v NAVIEN MODEL # CC -240A, GAS FIRED WATER HEATER, 199 MBH INPUT 195.2 MBH OUTPUT © 98% COMBUSTION EFFICIENNCY PROVIDED BY OWNER INSTALLED BY PLUMBING CONTRACTOR ® v COLD WATER PIPE SIZE CW COLD WATER PIPIE 1" HOT WATER PIPE SIZE HW HOT WATER PIPE HWR HOT WATER RETURN PIPE - -- ® WASTE /SOIL PIPE SIZE ______ V VENT PIPE 1 ' VENT PIPE SIZE W WASTE PIPIE P1 PLUMBING FIXTURE TAG GW GREASE WASTE PIPE CONDENSATE PIPE GW ® PLAN NOTE #1 CD CD GV GATE VALVE -Pi- FD EQUIPMENT TAG BALL VALVE -41 © FFD FLOOR DRAIN W/ FUNNEL Q PRESSURE GAUGE FS FLOOR SINK 0 FD FLOOR DRAIN SIP- UNION 0 FCO FLOOR CLEANOUT _1 1 L- VTR VENT THROUGH ROOF WCO WALL CLEANOUT % VTR VENT THRU ROOF -1 0.5" 1/2" PIPE SIZE BURIED PIPE ,S' 0.75" 3/4" PIPE SIZE 1" 1" PIPE SIZE -n- CHECK VALVE 1.25" 1.5" 1 -1 /4" PIPE SIZE 1 -1 /2" PIPE SIZE DN DOWN 2" 2" PIPE SIZE CONN CONNECT 2.5" 2 -1/2" PIPE SIZE EXIST. EXIST 3" 3" PIPE SIZE PRESS PRESSURE 0- PIPE ELBOW UP PSI POUNDS PER SQUARE o- PIPE ELBOW DOWN INCH -0-- PIPE TEE UP -e- PIPE TEE DOWN EQUIP EQUIPMENT RPBP REDUCED PRESSURE BACKFLOW ASSEMBLE MIN MINIMUM Typ TYPICAL PLUMBING EQUIPMENT SCHEDULE MARK DESCRIPTION ELECTRIC WATER HEATER - CRONOMITE MODEL # SR -15L, 4150W- 208V -1 PHASE 57 °F TEMP RISE © 0.3 GPM, PROVIDE WITH 0.5 GPM FLOW RESTRICTOR ® ® AM GREASE INTERCEPTOR - GREAT BASIN # GB -250, 250 GALLON CAPACITY PROVIDED BY OWNER INSTALLED BY PLUMBING CONTRACTOR v NAVIEN MODEL # CC -240A, GAS FIRED WATER HEATER, 199 MBH INPUT 195.2 MBH OUTPUT © 98% COMBUSTION EFFICIENNCY PROVIDED BY OWNER INSTALLED BY PLUMBING CONTRACTOR ® v BAC <FLOW PREVENTER OTES AS MANUFACTURED BY "WATTS" OR EQUAL: RPBA = REDUCED PRESSURE #009QT DCVA = DOUBLE CHECK #007QT AVB = VACUUM BREAKER 2. VALVES TO BE LINE SIZE. 3. INSTALL AT THE FOLLOWING LOCATIONS (MINIMUM): A. RPBA AT ICE MAKER B. RPBA AT COFFEE BREWER /ESPRESSO MACHINE (IF INSTALLED) C. WASHINGTON STATE APPROVED RPBA AT BEVERAGE BAR / CARBONATOR (POP MACHINE PIPING DOWNSTREAM OF CARBONATOR SHALL BE PLASTIC IN ORDER TO AVOID CARBONIC POISONING. BACKFLOW PREVENTERS SHALL BE MOUNTED 5 FEET MAXIMUM ABOVE FLOOR PER UPC 2006, SEC. 603.3.4. DISCHARGE DRAINS WITH AIRGAP, TYP. 4. BACKFLOW PREVENTERS SHALL BE FULLY INSTALLED AND TESTED PRIOR TO PRE - OPENING INSPECTION M � � A/C UNIT ON ROOF (120 MBH) A/C UNIT ON ROOF (120 MBH) f) 23' (789 MBH) 8' (590 MBH) 2" 1-1/2" 6' (470 MBH) 30' (120 MBH) WATER HEATER (199MBH) GAS PIPE SIZING GAS PIPING SIZED PER 2009 UPC TABLE 12 -8 "SCHEDULE 40 METALLIC PIPE, LESS THAN 7 'WC 77 LINEAR FEET + 30% FITTINGS LOSS =100' TOTAL DEVELOPED LENGTH, 789 MBH TOTAL GAS LOAD GAS DIAGRAM 1-1/4" GAS MANIFOLD w z m 0 CO w w SCALE: NONE SEPARATE E PERMIT AND APPROVAL REQUIRED m 0 m w >- w 0 m w Ct w RECEIVED SEP 07 2011 PERMIT CENTER ABOSSEDN ENGINEERING L.L.0 MECHANICAL - ELECTRICAL CIVIL - LEED - STRUCTURAL FIRE PROTECTION 2100 112TH AVE. NE BELLEVUE, WA 98004 OFFICE: (425) 462 -9441 FAX: (425) 462 -9451 EMAIL: CService@abossein.com WEBSITE: www.abossein.corn �O V E-1 TUKWILA, WASHINGTON 15037 TUKWILA INTERNATIONAL BLVD. AEI Revisions: PERMIT SET 6/14/11 ADDENDUM 1 6/22/11 ADDENDUM 2 6/28/11 ©CITY COMMENTS 8/29/11 Job No.: 211047 Date: 05/23/2011 P01 (1 OF 3) ABOSSEIN ENGINEERING L.L.0 GOO SEE 3/P01 /- 4 "GW Sc 4W FOR CONTINUATION SEE PARTIAL SITE PLAN' THIS SHT. MECHANICAL - ELECTRICAL CIVIL - LEED - STRUCTURAL FIRE PROTECTION 4'DRAIN WITI-NRIF1 GOO SEE DETAIL 3/P01 / 2 "V FOR CONTINUATION SEE PARTIAL SITE PLAN THIS SHT. 2100 112TH AVE. NE BELLEVUE, WA 98004 OFFICE: (425) 462 -9441 FAX: (425) 462 -9451 EMAIL: CService@abossein.com WEBSITE: www.abossein.com L BE ALL 2466SQ. NA N TUKWILA, WASHINGTON TACO TIME 4 "W FOR CONTINUATION SEE CIVIL DWG'S. STRAIGHT TEE GCO COORDINATE EXACT LOCATION WITH ARCH. 15037 TUKWILA INTERNAT x-- x— x- -x-- -x —'•- x--•— x--- x---- x---- �c---- x--- x-- -3c- -x x--- x--- K -�--x x x mac-- -tt PRE -RINSE SINK E 0 N PARTIAL SITE PLA\ SCALE: NONE 0 aEi o_ 0 0 0 I) 0 0 T 0 J w Z 0) 0 N 0 d- o N N 0 - w J GENERAL NOTES SS TABLE 6" STANDPIPE LAYOUT NAME: L FLOOR " P -TRAP STANDPIPE DRAI SCALE: NONE 1) COORDINATE WITH STRUCTURAL FOR EXACT LOCATION OF ALL STRUCTURAL FRAMING AND FOOTINGS AND FINALIZE THE EXACT ROUTING OF ALL PIPES WITH STRUCTURAL AND AT SITE PRIOR AND DURING THE CONSTRUCTION. 2) COORDINATE WITH ARCHITECTURAL AND AT SITE FOR EXACT LOCATION OF ALL PLUMBING FIXTURES. 3) ALL FIXTURES REQUIRING PLUMBING SHALL BE CONNECTED TO BUILDING WASTE, VENT, COLD WATER AND HOT WATER SYSTEM AS REQUIRED BY THE CODES. WASTE AND VENT PIPE SIZES SHALL NOT BE SMALLER THAN UPC 2006 TABLE 7 -5. 4) SEE PLUMBING FIXTURE CONNECTION SCHEDULE ON SHEET "Pr. 5) COORDINATE WITH OWNER /ARCHITECT FOR PLMBG. FIX. PRIOR TO BIDDING. 6) INSTALL CLEANOUTS PER UPC 2006 SECTION 707, SIZED PER TABLE 7 -6 AND AS REQUIRED BY LOCAL JURISDICTIONS. ALL CLEANOUTS SHALL BE LOCATED IN WALLS /FLOORS IN A NOT HIGHLY VISIBLE LOCATION AS APPROVED BY THE ARCHITECT. 7) ALL EXPOSED PIPING FOR HANDICAPPED FIXTURES SHALL BE INSULATED WITH HANDI -LAV GUARD (OR EQUAL). OFFSET P -TRAPS TO CLEAR WHEEL CHAIR ACCESS. 8) CONNECT TO EACH FIXTURE, EQUIPMENT, ETC. WITH ALL ACCESSORIES, VALVES, VACUUM BREAKERS, REGULATORS, UNION, ETC., AS REQUIRED AND AS RECOMMENDED BY THE MANUFACTURERS. 9) COORDINATE WITH THE STRUCTURAL ENGINEER AND GENERAL CONTRACTOR TO PROVIDE STRUCTURAL SUPPORT FOR ALL EQUIPMENT. 10) PLUMBING CONTRACTOR SHALL VERIFY ALL SPACE CONDITIONS AND DIMENSIONS AT JOB SITE PRIOR TO FABRICATION AND INSTALLATION OF MATERIALS AND EQUIPMENT. 1 1 ) PLUMBING CONTRACTOR SHALL COORDINATE PLUMBING VENT STACKS WITH THE HVAC CONTRACTOR TO MAINTAIN A MINIMUM OF 10 FT. FROM THE OUTSIDE AIR INTAKES. 12)INSTALL SHUT OFF VALVES /STOPS AT HOT AND COLD WATER SUPPLY TO EACH FIXTURE EQUIPMENT. 1 3) INSTALL ALL TRAP ARMS SUCH THAT THE MAXIMUM LENGTH WILL NOT EXCEED THE CODE REQUIREMENTS. ALL TRAPS WITHOUT HAVING CONTINUOUS WATER DISCHARGE TO BE PROTECTED AGAINST TRAP EVAPORATION AND TO HAVE AUTOMATIC TRAP PRIMERS CONNECTED TO NEAREST MOST FREQUENTLY USED FIXTURE. 14) SUDS RELIEF SHALL COMPLY WITH UPC 2006 SECTION 711. 15) ROUTE /DISCHARGE CONDENSATE PIPES FOR HEAT PUMPS /FURNACES TO LAVATORY TAILPIECE IN RESIDENTIAL UNITS OR TO APPROVED LOCATION PER LOCAL JURISDICTIONS. 16) ALL ROOF PENETRATIONS SHALL BE MINIMUM .5 FEET AWAY FROM AREA /OCCUPANCY SEPARATION WALLS. 17) VERIFY WITH GENERAL CONTRACTOR FOR FURRING OUT PIPES OUTSIDE OF WALLS DUE TO FLOOR STRUCTURAL FRAMING IN LINE WITH WALLS PRIOR TO BIDDING. �I ~. r41 ix r=4 g o 00 0�^Z LI Ew �PLI IRVIC Revisions: 18) VERIFY WITH GENERAL CONTRACTOR AND ARCHITECT FOR OUTSIDE ROOF AND DECK DRAINAGE LOCATIONS PRIOR TO BIDDING. (MAY NOT BE SHOWN ON THE DRAWINGS) 19) ALL DRAINAGE PIPING INSIDE BUILDING SHALL BE SLOPED AT MINIMUM 1/4" PER FOOT (2 %) UNLESS OTHERWISE APPROVED BY LOCAL JURISDICTIONS. (OTHER THAN 2% SLOPE WILL REQUIRE ADJUSTMENT FACTOR [0.80 FOR 1% SLOPE] FOR TOTAL F.U. COUNT CAPACITIES PER UPC 2006 TABLE 7 -5) 20) ALL WATER PIPING SHALL BE INSTALLED ON THE WARM SIDE OF INSULATION, INSULATE AND HEAT TRACE IN EXPOSED AREAS AS REQUIRED BY LOCAL CODE. 21) ALL PLUMBING, PIPING AND EQUIPMENT SHALL CONFORM TO SMACNA & LOCAL REGULATIONS FOR SEISMIC RESTRAINTS. 22) ALL PIPING SHALL BE INSULATED PER THE STATE ENERGY CODE. 23) ALL SUMP PUMPS TO HAVE ACCESSIBLE SHUT -OFF AND CHECK VALVE. 24) INSULATE ALL P -TRAPS IN EXPOSED AS REQUIRED BY CODE. 34" A.F.F. PERMIT SET 6/14/11 ADDENDUM 1 6/22/11 2 ADDENDUM 2 6/28/11 ACITY COMMENTS 8/29/11 Job No.: 211047 Date: 05/23/2011 FLOOR PLA\ - WASTE & VE SCALE: 1 /4" = 1' -0" SEPARATE PERMIT AND APPROVAL REQUIRED RECEIVED SEP 0 7 2011 PERM TCENTER ,_- _.:•urn Thursday, September 0 047_P03.dwg LAYOUT NAME: REVDATE: FILE NAM GENERAL NOTES 1) COORDINATE WITH STRUCTURAL FOR EXACT LOCATION OF ALL STRUCTURAL FRAMING AND FOOTINGS AND FINALIZE THE EXACT ROUTING OF ALL PIPES WITH STRUCTURAL AND AT SITE PRIOR AND DURING THE CONSTRUCTION. 2) COORDINATE WITH ARCHITECTURAL AND AT SITE FOR EXACT LOCATION OF ALL PLUMBING FIXTURES. 3) ALL FIXTURES REQUIRING PLUMBING SHALL BE CONNECTED TO BUILDING WASTE, VENT, COLD WATER AND HOT WATER SYSTEM AS REQUIRED BY THE CODES. WASTE AND PIPE SIZES SHALL NOT BE SMALLER THAN UPC 2006 TABLE 7 -5. 4) SEE PLUMBING FIXTURE CONNECTION SCHEDULE ON SHEET "P1 ". 5) COORDINATE WITH OWNER /ARCHITECT FOR PLMBG. FIX. PRIOR TO BIDDING. 6) INSTALL CLEANOUTS PER UPC 2006 SECTION 707, SIZED PER TABLE 7 -6 AND AS REQUIRED BY LOCAL JURISDICTIONS. ALL CLEANOUTS SHALL BE LOCATED IN WALLS /FLOORS IN A NOT HIGHLY VISIBLE LOCATION AS APPROVED BY THE ARCHITECT. 7) ALL EXPOSED PIPING FOR HANDICAPPED FIXTURES SHALL BE INSULATED WITH HANDI -LAV GUARD (OR EQUAL). OFFSET P -TRAPS TO CLEAR WHEEL CHAIR ACCESS. 8) CONNECT TO EACH FIXTURE, EQUIPMENT, ETC. WITH ALL ACCESSORIES, VALVES, VACUUM BREAKERS, REGULATORS, UNION, ETC., AS REQUIRED AND AS RECOMMENDED BY THE MANUFACTURERS. 9) COORDINATE WITH THE STRUCTURAL ENGINEER AND GENERAL CONTRACTOR TO PROVIDE STRUCTURAL SUPPORT FOR ALL EQUIPMENT. 10) PLUMBING CONTRACTOR SHALL VERIFY ALL SPACE CONDITIONS AND DIMENSIONS AT JOB SITE PRIOR TO FABRICATION AND INSTALLATION OF MATERIALS AND EQUIPMENT. 1 1) PLUMBING CONTRACTOR SHALL COORDINATE PLUMBING VENT STACKS WITH THE HVAC CONTRACTOR TO MAINTAIN A MINIMUM OF 10 FT. FROM THE OUTSIDE AIR INTAKES. 12) INSTALL SHUT OFF VALVES /STOPS AT HOT AND COLD WATER SUPPLY TO EACH FIXTURE EQUIPMENT. 13) INSTALL ALL TRAP ARMS SUCH THAT THE MAXIMUM LENGTH WILL NOT EXCEED THE CODE REQUIREMENTS. ALL TRAPS WITHOUT HAVING CONTINUOUS WATER DISCHARGE TO BE PROTECTED AGAINST TRAP EVAPORATION AND TO HAVE AUTOMATIC TRAP PRIMERS CONNECTED TO NEAREST MOST FREQUENTLY USED FIXTURE. 14) SUDS RELIEF SHALL COMPLY WITH UPC 2006 SECTION 711. 15) ROUTE /DISCHARGE CONDENSATE PIPES FOR HEAT PUMPS /FURNACES TO LAVATORY TAILPIECE IN RESIDENTIAL UNITS OR TO APPROVED LOCATION PER LOCAL JURISDICTIONS. 16) ALL ROOF PENETRATIONS SHALL BE MINIMUM 5 FEET AWAY FROM AREA /OCCUPANCY SEPARATION WALLS. 17) VERIFY WITH GENERAL CONTRACTOR FOR FURRING OUT PIPES OUTSIDE OF WALLS DUE TO FLOOR STRUCTURAL FRAMING IN LINE WITH WALLS PRIOR TO BIDDING. 18) VERIFY WITH GENERAL CONTRACTOR AND ARCHITECT FOR OUTSIDE ROOF AND DECK DRAINAGE LOCATIONS PRIOR TO BIDDING. (MAY NOT BE SHOWN ON THE DRAWINGS) 19) ALL DRAINAGE PIPING INSIDE BUILDING SHALL BE SLOPED AT MINIMUM 1/4" PER FOOT (2 %) UNLESS OTHERWISE APPROVED BY LOCAL JURISDICTIONS. (OTHER THAN 2% SLOPE WILL REQUIRE ADJUSTMENT FACTOR [0.80 FOR 1% SLOPE] FOR TOTAL F.U. COUNT CAPACITIES PER UPC 2006 TABLE 7 -5) 20) ALL WATER PIPING SHALL BE INSTALLED ON THE WARM SIDE OF INSULATION, INSULATE AND HEAT TRACE IN EXPOSED AREAS AS REQUIRED BY LOCAL CODE. 21) ALL PLUMBING, PIPING AND EQUIPMENT SHALL CONFORM TO SMACNA Sc LOCAL REGULATIONS FOR SEISMIC RESTRAINTS. 22) ALL PIPING SHALL BE INSULATED PER THE STATE ENERGY CODE. 23) ALL SUMP PUMPS TO HAVE ACCESSIBLE SHUT -OFF AND CHECK VALVE. 24) INSULATE ALL P- TRAPS IN EXPOSED AS REQUIRED BY CODE. z N) ROOF SOFFIT LINE 3" DIA. INTAKE & EXHAUST FLUES SCHEDULE 40 PVC —VENT TERMINATOR OUTLET (TYP) —12 MIN. MOUNT HEATER TO f� WALL PER MANUFACTURERS RECOMENDATIONS CW, HW & G PIPING SIZE AS SHOWN ON PLANS GRADE GAS WATER HEATER DETAIL / SCALE: NONE �.. %\. 1-1/2" CW FOR CONTINUATION I SEE CIVIL DWG' PRESSURE REDUCING VA CIVIL PLANS FOR EXAC LOCATION SPRI\ <L GAS METER BY PUGET SOUND ENERGY 789 MBH © 7'WC OUTLET PRESS. C TO PAY A tTIO N NTRACTOR L FEE ASSOC LLATION & CONN ( COORDINATE RCH ) 139" 2466SQ NA DINING 101 1" G UP TO AIR HANDLER ON ROOF 1 PAY WINDOW J JKY I UKAGE — IR HANDLER ON ROOF MANUAL AND AUTOMATIC COOKLINE GAS SHUT -OFF VALVE AT ±6' -6" A BELOW CEILING. (VERIFY LOCATION) 1-1/4" GAS MANIFOL F.F. 0.75" COOL 3/4 "G DROP CONN 1 COUNTER TOP BURNE 3/4 "G DROP CONN T FRYER RPBP MOUNT IN ACCESSIBLE LOCATI •ICI SIC 1111111111111101111111211111111.1 _ PROVIDE 1/2"CW CONIIJ TO ICE MAKE DLER F DRIVE -T RJ S -RVICE SEE 26ETAIL 2/P01 F.F. RPBP MOUNT IN ACCESSIBLE LOCATION PROVIDE 1 /2 "CW CONN TO ICE MAKER ENTRY SEE DETAIL 2/P01 FLOOR PLA\ PLUVB \ G SCALE: 1/4" = 1' -0" PLUVB \G FLOOR PLA\ Mai \OTES PROVIDE SHUT OFF VALVE AND DRIP LEG AT CONNECTION TO AIR HANDLER �. - -- _.,--..�,- -.,f•- °.a-- -,r--N.. -__ ,--, ---N - GAS FIRED WATER HEATER ( SEE SCHEDULE )PROVIDE GAS FLUE & TERMINATE MAX 4' -0" ABOVE WATER HEATER FIELD VERIFY AVAILABLE SPACE, PROVIDE PRESS RELIEF VALVE & PIPE 3/4" CONDENSATE DRAIN TO MOP SINK 5s SEE DETAIL THIS SHEET. RUN 1/2" H & CW PIPING UNDER SINK COUNTER TO FAUCET 42 TO FAUCET 42 0 8 4P wqrAliv RP pkq /D wtriZo RECEIVED SEP 07 2011 PPRMITCENTER ABOSSEIN ENGINEERIN G L. L. C MECHANICAL - ELECTRICAL CIVIL - LEED - STRUCTURAL FIRE PROTECTION 2100 112TH AVE. NE BELLEVUE, WA 98004 OFFICE: (425) 462 -9441 FAX: (425) 462 -9451 EMAIL: CService@abossein.com WEBSITE: www.abossein.com o H TUKWILA, WASHINGTON TUKWILA INTERNATIO LCD Revisions: PERMIT SET 6/14/11 A ADDENDUM 1 6/22/11 /IL ADDENDUM 2 6/28/11 ITY COMMENTS 8/29/11 iL- Job No.: 211047 Date: 05/23/201 1 P03 3 OF 3 '1111t WV HOOD INFORMATION HOOD N❑' MODEL LENGTH MAX, C❑ ❑KING TEMP, EXHAUST PLENUM SUPPLY PLENUM HOOD CONSTRUCTION HOOD CONFIG, TOTAL EXH, CFM RISER(S) TOTAL SUP, CFM RISER(S)' END TO END ROW WIDTH LENG, DIA, CFM S.P. WIDTH LENG, DIA, CFM S.P. 1. 5424 ND -2 -PSP -F 15' 0,00" 600 Deg, 3600 10" 34" Ansul R102 3600 - 1.013" 3240. Outside YES 782 LBS MUA 304 SS Where Exposed ALONE ALONE 1080 0,306" 0 2 4224 VHB -G 3' 6,00" 700 Deg, 525 10" 525 - 0,069" 0 304 SS 100% ALONE ALONE HOOD INFORMATION HOOD NO FILTER(S) LIGHT(S) UTILITY CABINET(S) FIRE SYSTEM PIPING HOOD HANGING WGHT TYPE QTY, HEIGHT LENGTH QTY, TYPE WIRE GUARD L❑CATI ❑N FIRE SYSTEM ELECTRICAL SWITCHES TYPE SIZE MODEL # QUANTITY LOCATI ❑N 1 Captrate Solo Filter wi 9 20" 20" 5 Screw In Compact Fluore p NO Right Ansul R102 3,0/3,0 311110KT 1 Light 1 Fan Outside YES 782 LBS MUA 10" 2 1080 0,306" 0 NO 136 LBS HOOD OPTIONS HOOD N❑. ❑PTI ❑N 1 INSULATI ❑N FOR BACK OF HOOD PERFORATED SUPPLY PLENUMS HOOD N❑, POS, LENGTH WIDTH HEIGHT TYPE RISERS) WIDTH LENG, DIA, CFM S,P, 1 Front 192" 16' 6" MUA 10" 28" 1,78 1080 0,306" 0,45 16 x 16 15 -5/8' x 15 -5/8' x 1 -7/8" 1,39 7,4 MUA 10" 28" DATE: 5/12/2011 1080 0,306" SCALE: 1/16 MASTER DRAWING MUA 10" 28" 1080 0,306" ND -2 Series with PSP Accessory Specification The ND -2 series hood with PSP accessory is a compensating canopy hood system rated for all types of cooking equipment, The hood shall have the size, shape and performance specified on drawings. Construction shall be type 430 stainless steel with a #3 or #4 polish where exposed, Individual component construction shall be determined by the manufacturer and ETL. Construction shall be dependent on the structural application to minimize distortion and other defects. All seams, joints and penetrations of' the hood enclosure to the lower outermost perimeter that directs and captures grease -laden vapor and exhaust gases shall have a liquid- tight continuous external weld in accordance with NFPA 96. Hood shall be wall type with fully welded 10 gauge corner hanging angles. Corner hanging angles have o. ,625 x 1,500 slot pre - punched at the factory, allowing hanging rods to be used for quick and safe Installations. Hanging rod and connect Is provided by and installed by others. Ventilator shall be furnished with U.L. classified captrate solo baffle filters, supplied in size and quantity as required by ventilator, The filters shall extend the full length of the hood and the filler panels shall not be more than 6" in width. The hood manufacturer shall supply complete computer generated submittal drawings Including hood section views) and hood plan view(s), These drawings must be available to the engineer, architect and owner for their use in construction, operation and maintenance, Exhaust duct collar to be 4" high with 1' flange, Duct sizes, CFM and static pressure requirements shall be as shown on drawings, Static pressure requirements shall be precise and accuratei air velocity and volume information shall be accurate within 1 -ft increments along the length of the ventilator, U.L. Incandescent light fixtures and globes shall be installed and pre -wired to a junction box. The light fixtures shall be installed with a maximum of 4'0" spacing on center and allow up to a 100 watt standard light bulb, The hood shall have' - A double wall Insulated front to eliminate condensation and increase rigidity. The insulation shall have a flexural modulus of' 475 EI, meet UL 181 requirements and be in accordance with NFPA 90A and 90B, - An integral front baffle to direct grease laden vapors toward the exhaust filter bank, - A built -in wiring chase provided for outlets and electrical controls on the hood face and shall not penetrate the capture area or require an external chaseway, - Low velocity make -up air (up to 90%) provided through front and side plenums (PSP accessory), - A removable grease cup for easy cleaning. The hood shall be ETL Listed as "Exhaust Hood Without Exhaust Damper ", ETL Sanitation Listed and built in accordance with NFPA 96, The hood shall be listed for 450 °F cooking surfaces at 150 CFM /ft, 600 °F cooking surfaces at 200 CFM /ft, and 700 °F cooking surfaces at 250 CFM /ft, RTD SENSOR INSTALLATION DETAIL NOTES' One RTD er Exhaust Riser 1 RTD has 3 wires that will need to be field wired to temp controller RTD will be factory Installed If exhuost risers are factory Installed If RTD Is to be field Installed It Is to be Installed no further than 4' from top of hood, . 1/2' NPT Ouk Seal (Adopter Body) Part 0 32 -0000 ose Buct (External Surface) 1 1/8' - 11/4' Diameter Hole e' Q i3k Seal (Lack Vosher tort 2 -00002 ng�TE TPBBT 3E Istance Temperature edor Part 0 M00- 3V -PO-4' PPoorrt i 32 -0000 ) 1/2' NPT Si* Seal (Nut) Part 032 -00002 BE 100-11V on Ring Cover t 100 90. eo m 60 90 40 90 10 FILTER COT,T,RCTION EFFICIENCY 2" Capt • Gtease -Stop Solo Filter 0.1 PARTICT :P. DIAMETER (») 10 RESISTANCE VS. AIRFLOW - 2" Cap, a GreamrStop°soio FA= 1.6 02 a 400 600 AIRFLOW (cfm) e0o SPECIFICATI ❑NI CAPTRATE. GREASE -ST ❑P° SOLO FILTER THE CAPTRATE GREASE-STOP SOLO FILTER IS A SINGLE -STAGE FILTER FEATURING A UNIQUE S- BAFFLE DESIGN IN C❑NJUNCTI ❑N WITH A SLOTTED REAR BAFFLE DESIGN, TO DELIVER EXCEPTIONAL FILTRATI ❑N EFFICIENCY, FILTER IS CONSTRUCTED OF 430 STAINLESS STEEL, AND SIZED TO FIT INTO STANDARD 2 -INCH DEEP HOOD CHANNEL <S), 100 UNITS SHALL INCLUDE STAINLESS STEEL HANDLES AND A FASTENING DEVICE TO SECURE THE TWO COMPONENTS WHEN ASSEMBLED, GREASE EXTRACTI ❑N EFFICIENCY PERFORMANCE SHALL REMOVE AT LEAST 75% OF GREASE PARTICLES FIVE MICRONS IN SIZE, AND 907. GREASE PARTICLES SEVEN MICRONS IN SIZE AND LARGER, WITH A CORRESPONDING PRESSURE DROP NOT TO EXCEED 1,0 INCHES OF WATER GAUGE, FILTER INFORMATION - CAPTRATE GREASE -STOP° SOLO NOMINAL SIZE (H x W) ACTUAL DIMENSIONS (H x W x D) FREE AREA (SQ. FEET) WEIGHT (POUNDS) VELOCITY (FEET PER MINUTE) STATIC PRESSURE (WATER GAUGE) 20 x 20 19 -5/8" x 19 -5/8' x 1 -7/8" 228 11 100 0,25 20 x 16 19 -5/8" x 15 -5/8' x 1 -7/8" 1,78 8.9 125 0,35 16 x 20 15 -5/8" x 19 -5/8' x 1 -7/8" 1,78 9,1 150 0,45 16 x 16 15 -5/8' x 15 -5/8' x 1 -7/8" 1,39 7,4 175 0,75 CAPTRATE FILTERS ARE BUILT IN COMPLIANCE WITH BUILT IN ACCORDANCE WITH NFPA No 96 NFPA #96 NSF STANDARD #2 UL STANDARD #1046 INT, MECH. CODE (IMC) ■ff, Ae".1 Zile/ 54" 16' U.L. Listed Screw In Compact Fluorescent Bulb 28' 7 Field Cut 10' X 34" Exhaust Riser 32' 64" FIELD CUT EXHAUST RISER HANGING ANGLE 20" CAPTRATE SOLO FILTER WITH HOOK 1' LAYER ❑F INSULATION FACTORY INSTALLED IN 3" INTERNAL STANDOFF, MEETS 0 INCH REQUIREMENTS FOR CLEARANCE TO COMBUSTIBLE SURFACES, 15' 0.00 "Nom. /15' 0,00 " ❑D 64' 10" 28' 8' 32' Utility Cabinet PLAN VIEW - Hood #1 15' 0.00" LONG 5424ND -2 -PSP -F NOTE' Additional hanging angles provided for hoods longer than 12 ft, SCREW IN COMPACT FLUORESCENT BULB, INCANDESCENT LIGHT FIXTURE -HIGH TEMP ASSEMBLY, INCLUDES CLEAR THERMAL AND SHOCK RESISTANT GLOBE 54' ATTACHING PLATES SUPPLY RISER WITH VOLUME DAMPER 2 3/4' 23.5% OPEN STAINLESS STEEL PERFORATED PANEL 6" - 24" N ❑M, IT IS THE RESPONSIBILITY OF THE ARCHITECT /OWNER TO ENSURE THAT THE HOOD CLEARANCE FROM LIMITED - COMBUSTIBLE AND COMBUSTIBLE MATERIALS IS IN COMPLIANCE WITH LOCAL CODE REQUIREMENTS. GREASE DRAIN WITH REMOVABLE CUP 48,0" MAX 104" 80" AFF TYP. EQUIPMENT BY OTHERS SECTION VIEW - MODEL 5424ND -2 -PSP -F --- 12" — REVIEWED FOR CODE COMPLIANCE APPROVED SEP 1 3 2011 City of Tukwila r UILDING DIVISION CORRECTION LTR #A. -- RECEIVED AUG 03 2011 PERMIT CENTER 14111-osa REVISIONS DESCRIPTION DATE: 0 A A A Seattle, WA DATE: 5/12/2011 DWG. #: 1345542 DRAWN BY: SCALE: 1/16 MASTER DRAWING SHEET NO. 1 PLENUM PROTECTION NOZZLE DUCT PR❑TECTI ❑N Y NOZZLE lk 1111441. 'N111.41111111111114: • C� J DETECTORS OPTIONAL PRE -WIRED ELECTRICAL TERMINAL BOX WITH TERMINAL STRIPS, 3 -PHASE CONTACTORS AND OVERLOADS (IF APPLICABLE) FAN AND LIGHT CONTROL PANEL ELECTRICAL PACKAGES TYPICAL ANSUL R -102 SYSTEM LAYOUT REMOTE MANUAL PULL STATI ❑N REMOVABLE STAINLESS STEEL SERVICE DOOR AGENT TANK OEM RELEASE/ BRACKET ASSEMBLY SPECIFICATIONS THE RESTAURANT FIRE SUPPRESSI ❑N SYSTEM SHALL BE THE PRE - ENGINEERED TYPE WITH A FIXED NOZZLE AGENT DISTRIBUTI ❑N NETWORK, IT SHALL BE LISTED WITH UNDERWRITERS LABORATORIES, INC, CUL) THE SYSTEM SHALL BE CAPABLE OF AUTOMATIC DETECTION AND ACTUATI ❑N WITH LOCAL OR REMOTE MANUAL ACTUATI ❑N, ACCESSORIES SHALL BE AVAILABLE FOR MECHANICAL OR ELECTRICAL GAS LINE SHUT -OFF APPLICATIONS, THE EXTINGUISHING AGENT SHALL BE A POTASSIUM CARBONATE, POTASSIUM ACETATE -BASED FORMULATI ❑N DESIGNED FOR FLAME KNOCKDOWN AND SECUREMENT OF GREASE RELATED FIRES. IT SHALL BE AVAILABLE IN PLASTIC CONTAINERS WITH INSTRUCTI ❑NS FOR LIQUID AGENT HANDLING AND USAGE, THE REGULATED RELEASE MECHANISM SHALL BE COMPATIBLE WITH A FUSIBLE LINK DETECTION SYSTEM. THE FUSIBLE LINK SHALL BE SELECTED AND INSTALLED ACCORDING TO THE OPERATING TEMPERATURE IN THE VENTILATING SYSTEM. THE FUSIBLE LINK SHALL BE SUPPORTED BY A DETECTOR BRACKET/ LINKAGE ASSEMBLY. N❑, TAG PACKAGE # LOCATION SWITCHES ROOFTOP STARTERS ❑PTI ❑N FANS CONTROLLED L ❑CATI ❑N QUANTITY TYPE 0 H.P. VOLT FLA 1 3 311110KT Utility Cabinet Right Utility Cabinet Right 1 Light 1 Fan Exhaust On Fire, Fans On/Off Thermostatically/Lights out fir Exhaust 3 1.500 208 4,7 Hood # 1 Supply 3 1.500 208 4.7 6 ELECTRICAL PREWIRE PACKAGE JOB NAME Taco Thee- Tukwila -Final DATE 5/12/2011 DRAWING NUMBER 311110KT JOB NUMBER 1345542 DRAWN BY CONTROL INPUT 120VAC H1 =LINE, N1= NEUTRAL 15A BKR - DO NOT WIRE TO SHUNT TRIP BREAKER H11 FS -01 N1 BL Q L - - (Fan Switch Shown Installed) 2 Al ST -1 OL -1 TC -01 4 OR '' 0; A 96 95 WH 3 4 5 8 8 10 11 -'1 E 1 Amp Max ST -2 /120A2 A2 OL -2 96.95 H 12 MS -1NC 13 0- 14 C1 NO O ,.TR1' 15 LIGHT INPUT 120VAC H2 -H5 =LINE, N2 -N5= NEUTRAL 15A BKR (MAX 1400W PER CIRCUIT) LS -00_11 1 Jumper Mat �C�- - B I-1--12) 1--12) LS 6'@ H ME 16 17 B R -- H2 LIGHTS OUT IN • FIRE CONDITION. 18 INPUT - 3 WIRE - 3 PHASE_ 19 20 21 22 23 24 3 PHASE 208V ST -1 OL -1 L1 T1 TT1 TLT3 3 PHASE 208V ST-2 L1 T1 OL T1 T -_- L3 �T2_ T3 l— ,Txti- -- NOTE 1: RTD TEMP SENSOR FIELD WIRED WHEN. RISERS SHIPPED LOOSE. WHEN MULTIPLE TEMP SENSORS USED ON ONE FAN SWITCH, EACH SENSOR IS WIRED TO ITS OWN CONTROLLER AND THE CONTROLLER TERMINALS 4. 7, 10 AND 11 ARE WIRED IN PARALLEL. A 1 AMP SLO -BLO FUSE CONNECTS BETWEEN TERMINALS 6 AND 8 ON EACH CONTROLLER. 3 Phase, W/ 1 Exhaust Fan, 1 Supply Fan, Exhaust in Fire, Lights out in Fire, Fan On /Off Thermostatically Controlled. COMPONENT PARTS LIST I sacl DESCRIPTION C -x Contactor ST -x Starter OL -x Overload FS -xx Fan Switch (Lighted) FUSE 1 AMP SLO -BLO FUSE- PS- 11_FUSE LS -xx Light Switch L Hood Ught(a) MS -x MicroSwitch (Ansul /PyroChem) Rx Relay DPDT - 34.110.0146.0 + Socket C -XX TEMPERATURE CONTROLLER PXR4- WAS1 -GV0A8 SN -X Temp Sensor A/100- 3W- PO- 4 " -EXPL (Note 1) SPARE FIRE DRY CONTACTS SPARE RELAY CONTACTS USED WHEN FIRE SYSTEM DISCHARGES TO SHUT DOWN SHUNT TRIP, EQUIPMENT... OR PROVIDE SIGNALS. R2 -1 __emu - -0AR2 Np - - C2 1TR: Tripped, AR: Armed, C: Common 1 Rx RELAY SOCKET STYLE "COON" C -RD NO NO -BL NC NC -PR COIL. COM 4 -r 8 7 615 MS -x MicroSwitch C -RD NO -BK NC -BR MOTOR TAG PH VLT HP FLA BRK EXH -1 3 208 1.5 4.7 15A SUP -2 3 208 1.5 4.7 -- NOTES - - -- DENOTES FIELD WIRING DENOTES INTERNAL WIRING WIRE COLOR BK - BLACK YW - YELLOW BL - BLUE GY - GRAY BR - BROWN PR - PURPLE OR - ORANGE OR /BL - ORANGE /BLUE (STRIPE) RD - RED BL /RD - BLUE /RED (STRIPE) . WH - WHITE RD /GN - RED /GREEN (STRIPE) DRAWING SHOWN DE- ENERGIZED NOTE: IF WALL MOUNT PREWIRE, OR FIELD INSTALLED FIRE SYSTEM MICROSWITCH, THE TERMINALS SHOWING FACTORY WIRING MUST BE FIELD WIRED. 12 x 18 x 6 Box **SOME WIRING DETAILS 1. CONTROL PANEL INSTALLATI ❑N v AY \DT APPLY JOB NAME Taco Time-Tukwila-Final DATE 5/12/2011 DRAWING NUMBER 311110KT JOB NUMBER 1345542 DRAWN BY 2 HOOD TO CONTROL PANEL HOOD LIGHT GN WH BK BR 4 CONTROL PANEL - GROUND B (No Lights out in Fire or LS (Lights out in fire) LIGHT SWITCH �� - - -- Hi 1 RED WEL -I N1 I PILOT OR -Dal SWITCH 5 Light switch and fan switch mounted on the face of the hood and control panel mounted separately then field wire to the control panel as shown. POWER FEED FOR CONTROLS AND LIGHTIN BREAKER PANEL CONTROL 120V 15A BREAKER- LIGHT 120V 15A BREAKER- 1 - J CONTROL PANEL -I Hl I -IN1I 6 FIELD WIRED SWITCHES TO CONTROL PANEL RED PILOT FAN SWITCH BL 7 r -- L 8 9 OR WH LIGHT SWITCH BK BR HOOD LIGHTS] 10 L BK Y!H -H Hi 1 CONNECTIONS IN CONTROL 1 Ni 1 PANEL - - H21 H B I B (No Lights out in Fir or LS (Lights out in fire) -H w1 DUCT STAT WIRING FOR FAN SWITCH OVERRIDE TEMPERATURE CONTROLLER BASE RTD SENSOR BROWN SHOWN HERE WITH TEMP CONTROLLER REMOVED TO EXPOSE TERMINALS 11 FIRE SYSTEM MICROSWITCH 120VAC SHUNT TRIP WIRING TO CONTROL PANEL BREAKER WIRING 12 ANSUL OR PYROCHEM FIRE SYSTEM 13 MICROSWITCH 14 15 MS -1 SPARE FIRE RELAY CONTACTS CONTROL PANEL PR BL SHUNT NEUTRAL 1.1134- NOTE2: IF NO FIRE SYSTEM ON HOOD, JUMPER C1 AND AR1 TOGETHER NOTE1: BUILDING FIRE ALARM IS TO BE WIRED TO THE "ALARM INITIATING SWITCH" INSIDE THE FIRE SYSTEM AUTOMAN MICRO - SWITCHES WIRING WHEN MULTIPLE FIRE SYSTEMS CONNECTED TO ONE ELECTRICAL PANEL (3 SHOWN HERE) NORMALLY CLOSED FS #1 NORMALLY OPEN LCOMMON 1 NORMALLY CLOSED] FS #2 NORMALLY OPEN LCOMMON NORMALLY CLOSED] FS #3 NORMALLY OPEN LCOMMON CONTROL PANEL -1 ci 1 FAN WIRING TO CONTROL 16 PANEL 3 PHASE 208/480/575 VOLT 17 18 19 20 21 22 23 24 FAN BREAKER PANEL, SEE DRAWING MOTOR TABLE FOR BREAKER SIZING STARTER STARTER 1 PHASE 115 VOLT 1 PHASE 208/230 VOLT --1 TO FAN #1 -I TO FAN #2 TO FAN #1 TO FAN #2 TO FAN #1 TO FAN #2 ELECTRIC GAS VALVE WITH RESET RELAY r MANUAL RESET RELAY ELECTRIC GAS VALVE (INSTALLED BY PLUMBER CONTROL PANEL -I Ni 1 HMI NOTES - - - -- DENOTES FIELD WIRING DENOTES INTERNAL WIRING WIRE COLOR BK - BLACK YW - YELLOW BL - BLUE GY - GRAY BR - BROWN OR - ORANGE RD - RED WH - WHITE GN - GREEN PR - PURPLE OR /BL - ORANGE/BLUE (STRIPE) BL /RD - BLUE /RED (STRIPE) RD /GN - RED /GREEN (STRIPE) EXHAUST RISER HANGING ANGLE IT IS THE RESPONSIBILITY OF THE ARCHITECT /OWNER TO ENSURE THAT THE HOOD CLEARANCE FROM LIMITED - COMBUSTIBLE AND COMBUSTIBLE MATERIALS IS IN COMPLIANCE WITH LOCAL CODE REQUIREMENTS. 4 42' 1 DRAIN 3/4 PERIMETER GUTTER EQUIPMENT BY OTHERS 24' NOM. Me" dfferAr SECTION VIEW — MODEL 4224VHB —G 4 2' 10' 21' 21' 21' 3' 6,00'Norn, /3' 6,00'0 PLAN VIEW — Hood #2 3' 6.00" LONG 4224VHB —G 104' 80" AFF TYP, VHB —G Series Specification The VHB -G series heat /condensate hood Is a single wall vent hood used In non - grease applications for the removal of' heat, vapor etc. Hood shall have the size, shape and performance specified on the drawings. Construction shall be type 304 stainless steel with a #3 or #4 polish where exposed, Hood shall have o. full perimeter gutter with a 1/2" ❑D Bolt thread drain connection. Hood shall be wall or Island type with fully welded 10 gauge corner hanging angles, Corner hanging angles have a .625 x 1.500 slot pre- punched at the factory, allowing hanging rods to be used for quick and safe Installations. Hanging rod and connection is provided by and installed by others. The hood manufacturer shall supply complete submittal drawings including hood section views(s) and hood plan view(s). These drawings must be made available to the engineer, architect and owner for their use In construction, operation and maintenance. Exhaust duct collar to be 4" high with 1" flanges, Duct sizes, CFM and static pressure requirements shall be as shown on the drawings. Hood shall be ETL Sanitation listed. M 1 REVIEWED FOR CODE COMPLIANCE APPROVED SEP 1 3 2011 City of Tukwila pUILDING DIVISION RECEIVED AUG 0 3 2011 PERMIT CENTER REVISIONS DESCRIPTION DATE: A SEATTLE OFFICE 2804 GRAND AVE., SUITE 203, EVERETT, WA, 98204 PHONE: (425) 212-5996 FAX: (425) 212-5998 EMAIL: reg85@captiveaire.com Tine-Tukwila 0 U d W f 0J DATE: 5/12/2011 DWG. #: 1345542 DRAWN BY: SCALE: 1/16 MASTER D WING SHEET NO. 2 EXHAUST FAN INFORMATION FAN ❑PTI ❑N (Qty, - Descr,) EXHAUST SUPPLY 1 1 - Grease Box SIDE DISCHARGE GRAVITY DAMPER MOTORIZED DAMPER 1 - Extra Set of Belts UNIT FAN UNIT MODEL # MODEL TAG CFM SP. RPM H.P. 0 VOLT FLA WEIGHT (LBS,) N❑, WEIGHT (LBS,) N❑, YES 31.000 "W x 31.000 "L x 20.000 "H 3 # 3 25 LBS 1 NCA18FA NCA18FA 2 3600 1.300 1030 1.500 3 208 4.7 155.77 3 DU12HFA DU12HFA 382.60 525 0275 1458 0.180 1 115 2.0 41.11 HEATER /MUA FAN INFORMATION FAN ❑PTI ❑N (Qty, - Descr,) EXHAUST SUPPLY 1 1 - Grease Box SIDE DISCHARGE GRAVITY DAMPER MOTORIZED DAMPER 1 - Extra Set of Belts 1 UNIT FAN UNIT MODEL # BLOWER H ❑USING TAG CFM S.P. RPM H.P. 0 VOLT FLA WEIGHT (LBS,) N❑, YES 31.000 "W x 31.000 "L x 20.000 "H 3 # 3 25 LBS Curb 2 A2 -G15 G15 -PB A2 3240 0.750 650 1.500 3 208 4.7 382.60 FAN OPTIONS FAN UNIT N❑, ❑PTI ❑N (Qty, - Descr,) EXHAUST SUPPLY 1 1 - Grease Box SIDE DISCHARGE GRAVITY DAMPER MOTORIZED DAMPER 1 - Extra Set of Belts 1 YES 2 1 - Extra Set of Belts 26.500 "L x 20,000 "H 1,000112,000 Pitch Vented 1 - Motorized Backdraft Damper for Size 2 Housing 3 1 - SCR -12 Bird Screen YES FAN ACCESSORIES FAN UNIT NO FAN UNIT TAG EXHAUST SUPPLY GREASE CUP GRAVITY DAMPER WALL MOUNT SIDE DISCHARGE GRAVITY DAMPER MOTORIZED DAMPER WALL MOUNT 1 1 YES Curb 26.500 "W x 26.500 "L x 20,000 "H 1,000112,000 Pitch Vented 2 2 # 2 42 LBS Curb YES CURB ASSEMBLIES NO FAON N WEIGHT ITEM SIZE 1 # 1 41 LBS Curb 26.500 "W x 26.500 "L x 20,000 "H 1,000112,000 Pitch Vented Hinged 2 # 2 42 LBS Curb 31.000 "W x 31.000 "L x 20.000 "H 3 # 3 25 LBS Curb 17,500 "W x 17.500 "L x 20.000 "H 1,000112.000 Pitch FAN #3 DU12HFA - EXHAUST FAN FEATURES: - ROOF MOUNTED FANS - UL705 - VARIABLE SPEED CONTROL - INTERNAL WIRING - WEATHERPROOF DISCONNECT - THERMAL OVERLOAD PR❑TECTI ❑N (SINGLE PHASE) OPTIONS SCR -12 BIRD SCREEN 17 1/2" 17 1/2' 20" 13" 13" FAN #1 NCA18FA - EXHAUST FAN 38 7/8' 33 318" 29 1/2' GREASE DRAIN 42" CURB 20 GAUGE STEEL C❑NSTRUCTI ❑N 3" FLANGE PITCHED CURBS ARE AVAILABLE FOR PITCHED ROOFS. ROOF OPENING DIMENSI ❑NS SPECIFY PITCH 12' EXAMPLE: 7/12 PITCH = 30° SLOPE " DUCTWORK BETWEEN EXHAUST RISER ON HOOD AND FAN (BY OTHERS) FEATURES: - ROOF MOUNTED FANS - RESTAURANT MODEL - UL705 AND UL762 - AMCA SOUND AND AIR CERTIFIED - WIRING FROM MOTOR TO DISCONNECT SWITCH - WEATHERPROOF DISCONNECT - HIGH HEAT ❑PERATI ❑N 300 °F (149 °C) - GREASE CLASSIFICATION TESTING NORMAL TEMPERATURE TEST EXHAUST FAN MUST OPERATE CONTINUOUSLY WHILE EXHAUSTING AIR AT 300 °F (149 °C) UNTIL ALL FAN PARTS HAVE REACHED THERMAL EQUILIBRIUM, AND WITH ❑UT ANY DETERI ❑RATING EFFECTS TO THE FAN WHICH WOULD CAUSE UNSAFE OPERATION. ABNORMAL FLARE -UP TEST EXHAUST FAN MUST OPERATE CONTINUOUSLY WHILE EXHAUSTING BURNING GREASE VAPORS AT 600 °F (316 °C) FOR A PERI ❑D OF 15 MINUTES WITH ❑UT THE FAN BECOMING DAMAGED TO ANY EXTENT THAT COULD CAUSE AN UNSAFE C❑NDITI ❑N, ❑PTI ❑NS GREASE BOX EXTRA SET OF BELTS 20" 26 1/2' 426 1/21 _Ivy 4,14/ FAN #2 A2 -G15 - SUPPLY FAN 1. UNTEMPERED SUPPLY UNIT WITH 15' .BLOWER IN SIZE #2 H ❑USING 2. INTAKE HOOD WITH EZ FILTERS 3, DOWN DISCHARGE - AIR FLOW RIGHT -> LEFT 4. EXTRA SET OF V- BELTS. ONLY TO BE ORDERED AS FAN ❑PTI ❑N AT TIME FAN IS ORDERED, 5. MOTORIZED BACK DRAFT DAMPER 22" X 24', STANDARD GALVANIZED C❑NSTRUCTI ❑N, 1 1/4' REAR FLANGE, WITH H- 2000A/8 MOTOR, WALL SUPPLY MOUNT, FOR SIZE 2 UNTEMPERED FAN H ❑USING (5192) LIFTING LUG 3 3/4' 20' EQUIPMENT CURB 37 3/8' 00 31' ROOF OPENING 2' SMALLER THEN CURB DIMENSI ❑N, 16 1/4' 5 1/2' BLOWER DISCHARGE CURB -� / 24' VENTED CURB 20 GAUGE STEEL C❑NSTRUCTI ❑N 3" FLANGE PITCHED CURBS ARE AVAILABLE FOR PITCHED ROOFS. ROOF OPENING DIMENSIONS SPECIFY PITCH: 12" EXAMPLE: 7/12 PITCH = 30° SLOPE 18 3/4' 6 1/8' 36 3/4' L_ " 16' FLEX CONDUIT FOR FIELD - WIRING REVIEWED FOR CODE COMPLIANCE APPROVED City of Tukwila pUILDING DIVISION M I 0 9 ° RECEIVED AUG 03 2011 PERMIT CENTER REVISIONS DESCRIPTION DATE: 0 A A 1 c (425) 212-5998 EMAIL: reg85@captiveaire.com 0a Lo C■ LO N w z 0 S fV (0 0) 1 w tY w w 0 (v w E- cn Z 0 Time-Tu-<w1( 0 u d Oi d Cu DATE: 5/12/2011 DWG.#: 1345542 DRAWN BY: SCALE: 1/16 MASTER DRAWING SHEET NO. 3 - 40 1/8' - AIRFL ❑W 4....... SERVICE DISCONNECT SWITCH BLOWER/MOTOR ACCESS DOOR 24' SERVICE _ CLEARANCE REQ. - REVIEWED FOR CODE COMPLIANCE APPROVED City of Tukwila pUILDING DIVISION M I 0 9 ° RECEIVED AUG 03 2011 PERMIT CENTER REVISIONS DESCRIPTION DATE: 0 A A 1 c (425) 212-5998 EMAIL: reg85@captiveaire.com 0a Lo C■ LO N w z 0 S fV (0 0) 1 w tY w w 0 (v w E- cn Z 0 Time-Tu-<w1( 0 u d Oi d Cu DATE: 5/12/2011 DWG.#: 1345542 DRAWN BY: SCALE: 1/16 MASTER DRAWING SHEET NO. 3