Loading...
HomeMy WebLinkAboutPermit M11-092 - SPEC EASTSPEC EAST 12628 INTERURBAN AV S M11-092 City oli'ukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.Rov MECHANICAL PERMIT Parcel No.: 0004800003 Address: 12628 INTERURBAN AV S TUKW Project Name: SPEC EAST Permit Number: M11 -092 Issue Date: 07/15/2011 Permit Expires On: 01/11/2012 Owner: Name: GATEWAY OLYMPIA INC Address: PO BOX 4900 #207 , SCOTTSDALE AZ 85261 Contact Person: Name: MIKE NELSON Address: 899 WEST MAIN , AUBURN WA 98001 Email: MIKEN @SEATTLEMECHANICAL.COM Contractor: Name: IECS INC. Address: P.O. BOX 19252 , SEATTLE, WA 98109 Contractor License No: IECS * * *044QL Phone: 253 - 939 -9495 Phone: 206 939 -9495 Expiration Date: 11/20/2012 DESCRIPTION OF WORK: PROVIDE AND INSTALL NEW 3 TON ROOF TOP UNIT AND 2 NEW RESTROOM EXHAUST FANS Value of Mechanical: $14,000.00 Type of Fire Protection: UNKNOWN Electrical Service Provided by: Permit Center Authorized Signature: /A -% / I hereby certify that I have read and examined this pe and know same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether sp. ified herein or not. Fees Collected: $355.06 International Mechanical Code Edition: 2009 Date' 1 The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or erforman e of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this pit. Signature: Print Name: 1 r \ This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Date: `7 /IS /// doc: IMC -4/10 M11-092 Printed: 07 -15 -2011 • • PERMIT CONDITIONS Permit No. M11 -092 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: Readily accessible access to roof mounted equipment is required. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 8: Manufacturers installation instructions shall be available on the job site at the time of inspection. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431- 3670). 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of arty of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IMC -4/10 M11-092 Printed: 07 -15 -2011 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Building Permit No. Mechanical Permit No. M 1 Oq).. Plumbing/Gas Permit No. 136 a .g _ Public Works Permit No. \—O (•1 Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION King Co Assessor's Tax No.: 000480003 Site Address: rr21544' INTERURBAN AVE. Tenant Name: spec space Property Owners Name: RREEF PROPERTY MGMT. Mailing Address: 12720 GATEWAY DRIVE, SUITE 200 TUKWILA WA. 98168 City Suite Number: New Tenant: Floor: ❑ Yes ❑..No State Zip CONTACT PERSON - who do we contact when your permit is ready to be issued Name: MIKE NELSEN Mailing Address: 899 west main Auburn wa. Day Telephone: 2 5 3 9 3 9 9 4 9 5 E -Mail Address: MIKEN@SEATTLEMECHANICAL.COM City Fax Number: State 253- 939 -9260 Zip GENERAL CONTRACTOR INFORMATION = (Contractor Inform -Won for Mechanical (pg 4) for Plmiabing and Gas :Piping (pg 5)) Company Name: Mailing Address: Contact Person: E -Mail Address: Contractor Registration Number: City Day Telephone: Fax Number: Expiration Date: State Zip ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: Mailing Address: Contact Person: E -Mail Address: City Day Telephone: Fax Number: State Zip ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: CT Engineering inc . Mailing Address: 181 Nickerson st. Suite 302 City State Zip Day Telephone: 206- 285 -4512 E -Mail Address: Fax Number: 206-285-0618 Contact Person: Rick Hudson Q:\Applications\Fonns- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh Page 1 of 6 MECHANICAL CONTRACTOR INFORMATION Company Name: IECS INC Mailing Address: 899 WEST MAIN AUBURN WA. 98001 City State Zip Day Telephone: 253- 939 -9495 E -Mail Address: SEATTLE MEHCANICAL Fax Number: 253- 939 -9260 Contractor Registration Number: IECS * * * 044 QL Expiration Date: 11 / 20/ 2 011 Contact Person: MIKE NELSEN Valuation of Mechanical work (contractor's bid price): $ 14000 Scope of Work (please provide detailed information): PROVIDE AND INSTALL NEW 3 TON ROOF TOP UNIT . 2 NEW RR EXHAUST FANS . Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New .... ® Replacement .... ❑ Fuel Type: Electric ❑ Gas....® Other: Indicate type of mechanical work being installed and the quantity below: Unit Type: I Qty Unit Type: Qty Unit Type: Qty 1 Boiler /Compressor: Qty Furnace<100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace>100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct 2 Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM 1 Incinerator — Comm/Ind Q:\Applications'Foans- Applications On Line\3 -2006 - Permit Application.doc Revised: 9-2006 bh Page 4 of 6 PERMITAPPIICATIONNOTESappl>< ableto a11Mper utsintWs application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDIN ?RIZED_ ER AU AGENT: Signature: Print Name: MIKE NELSEN Mailing Address: 899 WEST MAIN AUBURN WA . 98001 Date: 7 -7 -2011 Day Telephone: 253-939-9495 City State Zip Date Application Accepted: .....-7` 4 I Date Application Expires: b.._ _./ y Staff Initials: l Q:WpplicationsTonns- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh Page 6 of 6 of Tukwila, Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 • Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: hup://www.ci.tukwila.wa.us SET RECEIPT RECEIPT NO: R11 -01389 Initials: WER Payment Date: 07/07/2011 User ID: 1655 Total Payment: 475.81 Payee: IECS INC SET ID: 070711 SET NAME: SPEC EAST SET TRANSACTIONS: Set Member Amount M11 -092 355.06 PG11 -094 120.75 TOTAL: 355.06 TRANSACTION LIST: Type Method Description Amount Payment Check 49154 475.81 TOTAL: 475.81 ACCOUNT ITEM LIST: Description Account Code Current Pmts GAS - NONRES MECHANICAL - NONRES PLAN CHECK - NONRES 000.322.103.00.0 000.322.102.00.0 000.345.830 96.60 284.05 95.16 TOTAL: 475.81 - INSPECTION RECORD Retain a copy with permit 3 INSPECTIOWNO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 12. (206) 431-367 Permit Inspection Request Line (206) 431-2451 Project: .s,-)M P/757- Type of Inspection: Address: /2 6,2,1 .,,sile'iit i idtvt,,,,, Date Called: Special Instructions: Date Wanted: q,..rnidn. Requester: Phone No: liaApproved per applicable codes. Corrections required prior to approval. COMMENTS: Date: 7'-/2-1 ) SPECTION FEE REWIRED. P or to next inspection. fee must be ‘id at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. ' INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 op.. (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project Pe 5( Type nA) AL • t Address:�v r ` 4. I�PV? to ate Called: Special Instructions: - ,- Date Wanted: / , - q•-- ( ( p.m. 1 Requester: Ph a No V, -39Co,- rs30 Approved per applicable codes. corrections required prior to approval. 7 COMMENTS: INJ p vAJ _ O'\ S f' Li i r R — & Q A o�►/�pi-A4"( ) A -s ,f 1 C �- t �� tn( - SC..J � � ICJ\ u \Q n 0 Inspector: Date: j /T ri ❑ REINSPECTION FEE REQUI D. Prior to next inspection. fee must be paid at 6300 Southcenter B4 d.. Suite 100. Call to schedule reinspection. M't(:- dgi2...y �.; - . - " .. • INSPECTION RECORD • Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISIONR'c---- 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 4313670 Permit Inspection Request Line (206) 431 -2451 Project;. p eASr_ Typ of Inspection: J Address: _ i 2 6 28 = Atre.J✓1 _4A-if Date Called:1 Special Instructions: v/ 5 ('7 2 �i of Date Wanted: --- % - 7-7 - If p.m. Requester: Phone Nob - !i 5 S - 0 045 Approved per applicable codes. D Corrections required prior to approval. COMMENTS: t7 r` to ' '`6 1)Jejr Inspector: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. ; INSPECTION NO. INSPECTION RECORD Retain a copy with permit 717 /'-52 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: 4r)ig efiC67 - Type of Inspection: . 1-4)0/4h -.A / Address: 1,.? ( e --,--Airi2>43/) Date Called: Ai .. Special Instructions: Date Wanted: Requester: Phone No: e-Q 4 --,-,2 5-5 -791S ....14'Approved per applicable codes. ElCorrections required prior to approval. COMMENTS: Inspecto Date: CTION FEE REQUI D. Prior to n t inspection. fe must be • 300 Southcenter Blvd.. Suite 100. raLt to schedule reinspection. • Load Express: Load Calculation Software FILE COPY Version 2.2 Title Page Load Express: Load Calculation Software By: Mike Nelsen General Job Job Description: Building Owner: Program User: Comments: Tukwila Comm Park C 105 CBR Richard Ellis Mike Nelsen Program was Run: 7/ 6/2011 at 7:53:58 AM Dataset Name: C: \CDS \LOADEXP \DATA \TCP105.LE Alternative 1 AIt1 Geographical Data Location: Tukwila Weather File: Seattle, Washington Latitude: 47 deg Elevation: 386 ft Design Data Summer Dsn Dry Bult Summer Dsn Wet Bul Winter Design Dry Bu Density-Sp Heat Prod Design Simulation per 80.0 deg F 64.0 deg F 26.0 deg F 1.0988 Btu - min /(hr -ft3 -F) Apr To Nov t,'t(L' 0q2 Building Peak Data Month /Hour: Jul / 14 Cooling Capacity: 32.1 Mbh Cooling Sensible: 26.9 Mbh Sensible Heat Ratio (.SH 0.875 Heating Capacity -40.2 Mbh REVIEWED FOR CODE COMPLIANCE APPROVED !JUL 14 2011 • City of Tukwila BUILDING DIVISION RECEIVED JUL 07 2011 PERMITCENTEf . Load Express: Load Calculation Software Version 2.2 Zone /Air Handler Descriptions Zone /Air Handler Descriptions Alternative - 1 AIt1 Air Handler Type Description 1 CONSTANT AHU1 Zone Type Description 1 Commercial Retail Zone1 Load Express: Load Calculation Software Alternative 1 Alt1 1 -2 Story Office Version 2.2 Zone Input Data ' General Job Data Weather Location: Seattle, Washington Weather Region: Northwest CIg Simulation Start Month: Apr CIg Simulation End Month: Nov Zone Data Alternative Number: 1 Zone Number: 1 Floor Width: 44 ft Floor Length: 27 ft Ceiling Height: 9 ft Flr- to -Flr Height: 14 ft No. of Dup Zones: 1 Ceiling U- Factor: 0.03 Btu /(hr -F -ft2) Floor Calculation Type: Slab -On -Grade Floor Loss Coefficient: 0.70 Btu /(hr -F -ft) Floor Perimeter Length142.00 ft W H ft ft Type Building Opening Time: Building Closing Time: Building Direction: CIg Sensible SF: Cooling Dry Bulb: Relative Humidity: Heating Dry Bulb: People Density: People Activity: People Sensible Load: People Latent Load: Misc. Equip. Type: 8 am Clg Latent SF: 0 6 pm Htg Sensible SF: 5 0 People Diversity: 100 % 5.00 Bldg Simulation Type: Cooling and Heating 73 deg F 50 % 70 deg F 10 people General Office Space 210 Btuh /pers 255 Btuh /pers Std appliances Misc. Equip. Sensible Load 0.50 Watt/ft2 Misc. Equip. Latent Load: 0.00 Watt/ft2 Misc. Equip. Sensible to RV 0 Btuh Lighting Intensity: 2.00 Watt/ft2 Lighting Type: ecessed fluorescent, not vented Ballast Factor: 1.00 % Percent Light to RA: 0 % Vent Type: General Office Space Vent Cool Design: 20.00 cfm /pers Vent Heat Design: 20.00 cfm /pers Supply Cool Design: 0 cfm Supply Heat Design: 0 cfm Infiltration Type: Pressurized, Average Construction Infilt. Cooling Desigi Infilt. Heating Desigi Room Exhaust: 0.30 0.30 160.00 ach /hr ach /hr cfm U- Factor Color Percent ( %) Direction Susp Ceil Tilt Cool Adj Heat Adj Dimension % Glass Shading Coeff Spc Temp Spc Temp degF deg F WALL 1 44 x GLASS 1 29 x WALL 2 27 x GLASS 1 12 x ROOF 1 44 x PART 1 44 x PART 2 27 x 9 Face Brick, 6" L.W. Concrete, 6" Ins 7 Double Clear 1/8 in. 9 8" L.W. Concrete Blk, 6" Ins 9 Double Clear 1/8 in. 27 4" Wood deck, 4" Ins 9 Frame, 0.75" gypsum board 9 Frame, 0.75" gypsum board 0.06 Light North 0.60 0 Plenum 0.04 Light East 0.60 0 Plenum 0.04 Light 100 RA North 0.39 0.39 0 0 0 0 0 0 0 0 Yes 0 0 0 85 0 85 0 0 Area 0 0 Area 0 55 55 0.00 0.88 0.00 0.88 0.00 0.00 0.00 Shading Extemal Extemal Load Express: Load Calculation Software Version 2.2 Air Handler Input Air Handler Input Alternative 1 Air Handler 1 Fan Configuration: Fan & Motor Efficiency: Cooling Supply Air Temp: Heating Supply Air Temp: Minimum Relative Humidity: Supply Fan Static Pressure: Return Fan Static Pressure: CONSTANT AHU1 Draw 77.00 % 55.00 deg F 0.00 deg F 45 % 1.00 in H2O 0.00 in H2O Supply Duct Location: Supply Duct Insulation: Supply Duct Temp Rise: Return Duct Insulation: Return Duct Temp Rise: Terminal Type: Total Cool Airflow: Total Heat Airflow: Zone(s) Connected: Retum Air R4 Duct Insulation 0.3 deg F TD R4 Duct Insulation 0.3 deg F TD CONSTANT 0 cfm 0 cfm 1 Load Express: Load Calculation Software versio2.2 Peak Load Information Altemative 1 Design Heating: Airflow (cfm) Space Total Heating Coil Total Outside % O.A. Sensible Sensible Entering Leaving Humidification Air Handler #!Type Btuh Btuh DB DB Btuh BLDG BLOCK - 21,034.90 - 40,162.20 - 6,422.9 BLDG PEAK - 21,034.90 - 40,162.20 - 6,422.9 1 CONSTANT 1,283.07 200.00 15.59 - 21,034.90 - 40,162.20 61.37 84.92 - 6,422.9 Design Cooling: Airflow (cfm) Cooling Cooling Coil Total Outside % O.A. Total Sensible S.H.R. Entering Leaving Air Handler it/Type Btuh Btuh DB WB DB WB BLDG BLOCK 32,128.70 28,291.50 0.88 BLDG PEAK 32,128.70 28,291.50 0.88 1 CONSTANT 1,283.07 200.00 15.59 32,128.70 28,291.50 0.88 74.28 61.00 54.23 52.25 ft2lton cfm/ton cfm/ft2 Total tons 443.72 2.7 443.72 2.7 443.72 479.2 1.1 2.7 Building Peak Load Components Cooling (Btuh) Heating (Btuh) Mo1Hr: Solar Cond Internal OA +Inf Misc Total Cond OA +Inf Misc Total Bldg 7/14 8,634.3 4,017.8 13,647.6 3,069.6 1,412.1 30,781.4 - 19,748.5 - 12,254.3 - 6,246.9 - 38,249.7 Air Hand 1 7/14 8,634.3 4,017.8 13,647.6 3,069.6 1,412.1 30,781.4 - 19,748.5 - 12,254.3 - 6,246.9 - 38,249.7 Zone 1 7/14 8,634.3 4,017.8 13,647.6 3,069.6 1,412.1 30,781.4 - 19,748.5 - 12,254.3 - 6,246.9 - 38,249.7 • Load Express: Load Calculation Software Psychrometric State Points - Alternative 1 AIt1 Zone 1 Dry Bulb Wet Bulb Temp Diff. Zonel ( deg F ) ( deg F ) ( deg F ) Space 73.0 60.3 Zone Retum Air Heat Pickup Return Fan Return Air 73.3 60.4 Outdoor Air 79.4 64.3 Retum /Outdoor Air Mix 74.3 61.0 Blow Through Fan Entering Coil 74.3 61.0 Leaving Coil 54.2 52.3 Draw Through Fan Supply Duct Heat Gain Supply Air 55.0 52.6 Percent Outside Air Space Sensible Heat Ratio (SHR) Coil Airflow 16.37 % 0.904 1,222 cfm 0.3 0.0 0.0 0.5 0.3 Version 2.2 Psychrometrics Load Express: Load Calculation Software Version 2.2 Sensible Load Profile Sensible Load Profile (Mbh)- Alternative 1 AIt1 Hour 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Air Hand 1 3 2 2 1 1 2 5 16 19 21 23 25 26 27 27 26 25 24 12 8 7 5 4 4 Bldg 3 2 2 1 1 2 5 16 19 21 23 25 26 27 27 26 25 24 12 8 7 5 4 4 Zone 1 3 2 2 1 1 2 5 16 19 21 23 25 26 27 27 26 25 24 12 8 7 5 4 4 Load Express: Load Calculation Software Version 2.2 Peak Load Summary Peak Load Summary - Alternative 1 Air Hand 1 AHU1 Areas ( ft2 ) Floor: 1,188.0 SlabOnG /ExFIr: 142.0 Roof: 1,188.0 Skylight: 0.0 Wall: 328.0 Wall Glass: 311.0 Partition: 639.0 AIt1 Space Sens Load Spc Sens Ld W /Sfty Fctr Cool Airflow Cool Airflw W /Sfty Fctor Cooling Check Cool Check W /Sfty Fctr Heat Airflow Heat Airflw W /Sfty Fctr 24,169.1 Btuh 25,377.6 Btuh 1,222 cfm 1,283 cfm 1.03 cfm /ft2 1.08 cfm /ft2 1,222 cfm 1,283 cfm Heating Coil Peak Outside Air: OADB: 26 Cooling Coil Peak Peaked at Time: Mo /Hr: 7 / 14 Outside Air: OADB: 79 WB: 64 RELHUM: 44.2% Cooling Coil Peak Heating Coil Peak Total Load Sens Load Percnt of Tot Peak Tot Sens Percnt of Tot ( Btuh) ( Btuh ) ( %) ( Btuh) ( %) ENVELOPE LOADS Solar Skylight Solar 0.00 0.00 0.00 Glass Solar 8,634.31 8,634.31 0.00 Sub Total 8,634.31 8,634.31 28.05 0.00 0.00 Conducted Skylight 0.00 0.00 0.00 Roof -47.68 -47.68 - 2,299.97 Glass 1,108.65 1,108.65 - 8,641.57 Wall -3.02 -3.02 - 733.52 Partition 2,959.85 2,959.85 - 3,699.81 SlabOnG /ExFIr 0.00 0.00 - 4,373.60 Sub Total 4,017.80 4,017.80 13.05 - 19,748.50 51.63 INTERNAL LOADS Lights 7,150.60 7,150.60 0.00 People 4,558.27 2,008.27 0.00 Misc 1,938.77 1,938.77 0.00 Sub Total 13,647.60 11,097.60 44.34 0.00 0.00 MISC LOADS Outside Air 2,422.14 1,406.49 - 9,669.63 Humidification 0.00 0.00 - 6,422.86 Infiltration 647.44 375.96 - 2,584.69 Sup. Fan Heat 634.79 634.79 0.00 Ret. Fan Heat 0.00 0.00 0.00 Duct Heat Pkup 805.64 805.64 0.00 Exhaust Heat -28.32 -28.32 175.91 Sub Total 4,481.69 3,194.55 14.56 - 18,501.30 48.37 OV /UNDR Sizing 0.00 0.00 0.00 Grand Total 30,781.40 26,944.30 - 38,249.70 W /Safety Factor 32,128.70 28,291.50 - 40,162.20 Loab Express: Load Calculation Software Version 2.2 Peak Load Summary Peak Load Summary - Alternative 1 AIt1 Bldg 1 Areas ( ft2 ) Floor: 1,188.0 SlabOnG /ExFIr: 142.0 Roof: 1,188.0 Skylight: 0.0 Wall: 328.0 Wall Glass: 311.0 Partition: 639.0 Heating Coil Peak Outside Air: OADB: 26 Cooling Coil Peak Peaked at Time: Mo /Hr: 7 / 14 Outside Air: OADB: 79 WB: 64 RELHUM: 44.2% Cooling Coil Peak Heating Coil Peak Total Load Sens Load Percnt of Tot Peak Tot Sens Percnt of Tot ( Btuh) ( Btuh ) ( %) ( Btuh) ( %) ENVELOPE LOADS Solar Skylight Solar 0.00 0.00 0.00 Glass Solar 8,634.31 8,634.31 0.00 Sub Total 8,634.31 8,634.31 28.05 0.00 0.00 Conducted Skylight 0.00 0.00 0.00 Roof - 47.68 -47.68 - 2,299.97 Glass 1,108.65 1,108.65 - 8,641.57 Wall -3.02 -3.02 - 733.52 Partition 2,959.85 2,959.85 - 3,699.81 SlabOnG /ExFIr 0.00 0.00 - 4,373.60 Sub Total 4,017.80 4,017.80 13.05 - 19,748.50 51.63 INTERNAL LOADS Lights 7,150.60 7,150.60 0.00 People 4,558.27 2,008.27 0.00 Misc 1,938.77 1,938.77 0.00 Sub Total 13,647.60 11,097.60 44.34 0.00 0.00 MISC LOADS Outside Air 2,422.14 1,406.49 - 9,669.63 Humidification 0.00 0.00 - 6,422.86 Infiltration 647.44 375.96 - 2,584.69 Sup. Fan Heat 634.79 634.79 0.00 Ret. Fan Heat 0.00 0.00 0.00 Duct Heat Pkup 805.64 805.64 0.00 Exhaust Heat -28.32 -28.32 175.91 Sub Total 4,481.69 3,194.55 14.56 - 18,501.30 48.37 OV /UNDR Sizing 0.00 0.00 0.00 Grand Total 30,781.40 26,944.30 - 38,249.70 W /Safety Factor 32,128.70 28,291.50 - 40,162.20 , Load`Express: Load Calculation Software Version 2.2 Peak Load Summary Peak Load Summary - Alternative 1 Zone 1 Zone1 Areas ( ft2 ) Floor: SlabOnG /ExFIr: Roof: Skylight: Wall: Wall Glass: Partition: 1,188.0 142.0 1,188.0 0.0 328.0 311.0 639.0 AIt1 Space Sens Load Spc Sens Ld W /Sfty Fctr Cool Airflow Cool Airflw W /Sfty Fctor Cooling Check Cool Check W /Sfty Fctr Heat Airflow Heat Airflw W /Sfty Fctr 24,169.1 25,377.6 1,222 1,283 1.03 1.08 1,222 1,283 Btuh Btuh cfm cfm cfm /ft2 cfm /ft2 cfm cfm Heating Coil Peak Outside Air: OADB: 26 Cooling Coil Peak Peaked at Time: Mo /Hr: Outside Air: OADB: WB: RELHUM: 7 / 14 79 64 44.2% Cooling Coil Peak Heating Coil Peak Total Load Sens Load Percnt of Tot Peak Tot Sens Percnt of Tot ( Btuh) ( Btuh ) ( %) ( Btuh) ( %) ENVELOPE LOADS Solar Skylight Solar 0.00 0.00 0.00 Glass Solar 8,634.31 8,634.31 0.00 Sub Total 8,634.31 8,634.31 28.05 0.00 0.00 Conducted Skylight 0.00 0.00 0.00 Roof - 47.68 -47.68 - 2,299.97 Glass 1,108.65 1,108.65 - 8,641.57 Wall -3.02 -3.02 - 733.52 Partition 2,959.85 2,959.85 - 3,699.81 SlabOnG /ExFIr 0.00 0.00 - 4,373.60 Sub Total 4,017.80 4,017.80 13.05 - 19,748.50 51.63 INTERNAL LOADS Lights 7,150.60 7,150.60 0.00 People 4,558.27 2,008.27 0.00 Misc 1,938.77 1,938.77 0.00 Sub Total 13,647.60 11,097.60 44.34 0.00 0.00 MISC LOADS . Outside Air 2,422.14 1,406.49 - 9,669.63 Humidification 0.00 0.00 - 6,422.86 Infiltration 647.44 375.96 - 2,584.69 Sup. Fan Heat 634.79 634.79 0.00 Ret. Fan Heat 0.00 0.00 0.00 Duct Heat Pkup 805.64 805.64 0.00 Exhaust Heat -28.32 -28.32 175.91 Sub Total 4,481.69 3,194.55 14.56 - 18,501.30 48.37 OV /UNDR Sizing 0.00 0.00 0.00 Grand Total 30,781.40 26,944.30 - 38,249.70 W /Safety Factor 32,128.70 28,291.50 - 40,162.20 7 / 14 79 64 44.2% Cooling Coil Cooling Coil Cooling Coil I Internal 44% Other 15% Internal 44% Other 48% Alternative -1 Zone1 Alternative -1 AHU1 Heating Coil Heating Coil Other 48% $ Other 15% Alternative -1 Building I Internal 44% I Other 15% Heating Coil $ Other 48% 30 25 20 15 10 5 0 1 Alternative -1 Zone1 Sensible Load Profile (Mbh) 30 - 25 - 20 - 15 10 5 0 8 1 + p i 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Time (Hours) Alternative -1 AHU1 Sensible Load Profile (Mbh) 1 1 t f 30 - 25 - 20 - 15- 10- 5- 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Time (Hours) Alternative -1 Building Sensible Load Profile (Mbh) 0ill1111---711—'11-1 1 2 3 4 5 6 7 8 1 4 9 X10 X11 12 13 X14 X15 X16 117 X18 X19 20 21 22 23 20 Time (Hours) a CT E N G I N E E R I N G Structural Engineers INC FILE COPY Permit No. STRUCTURAL CALCULATIONS NEW ROOF TOP UNIT AT TUKWILA COMMERCE PARK C105 TUKWILA WA GENERAL CONTRACTOR PRECISION BUILDERS INC. MECHANICAL CONTRACTOR SEATTLE MECHANICAL 180 Nickerson St. Suite 302 Seattle, WA 98109 (206) 285-4512(V) (206) 285-0618(F) REVIEWED FOR CODE COMPLIANCE APPROVED JUL 14 2011 City of Tukwila BUILDING DIVISION RECEIVE JUL 071011 PERMIT CENTER 6 19Al2-K-L - 120 LTDI c 4rr4-0 g-00F Tor u t k.-`f %) 2-011 50' 7 aagwnH and c 70 7V m z 0 m 0 re 0 C T E N G I N E E R I N G 1� ,� , "� M I NNjC. Project: Tuk.W %Lk cW�i]�' I�J144E - G . 1 oCj Client: P +J- Date: -7 )1 [Z4311 Page Number: 180 Nickerson St. Suite 302 Seattle, WA 98109 (206) 28S-4512 FAX: (206) 285 -0618 Structural Engineers • C T E N G I N E E R I N G I N C. Project: Tv MLw I L A COWVNEj Client: 19' `r. - G t0S Date: j ( f Zcil Page Number: ✓ 3 180 Nickerson St. Suite 302 Seattle, WA 98109 (206) 285 -4512 FAX: (206) 285-0618 t12 k S 05 erel9t: �-VNIr To 60E6. emu) 14- V P1•G W.1 Cc W1 PS CA Off` Vint Pct. 2x4 Stvn�S�N A aft a-pr, 510£ f XiM 1 NC, WOOP ST I., RE FOR-C.( N SEc,T1 -A- Jo -7c oIQ a> Structural Engineers C T E N G I N E E R I N G nINC. Project: "TVkWI COUVIYp , y.A. Pekrlt., C � l rj Client: r r t r ..L . Date: Page Number: 180 Nickerson St. Suite 302 Seattle, WA 98109 (206) 285 -4512 FAX: (206) 285 -0618 Structural Engineers 48TC Gas Heat /Electric Cooling Packaged Rooftop 3 to 12.5 Nominal Tons Product Data Turn to the Experts. FILE COPY r.,..,...,•� R 1 WeatherMaker' (Unit shown with optional economizer.) This product has been designed and manufactured to meet Energy Starib criteria for energy efficiency. However, proper refrigerant charge and proper elr flow are critical to achieve rated capechy and efficiency. Installation of this product should follow all manufacturer's refrigerant charging and air lbw instructions. Failure to confirm proper charge and eh flow may reduce energy efficiency and Morten equipment 1110. MU Puron s,..m0cnnuash sand r.bl,wN 92 C08514 REVIEWED FOR CODE COMPLIANCE APPROVED 'JUL 14 2011 City of Tukwila BUILDING DIVISION ECEOVED JUL 07 2011 PERMIT CENTER U H oo MODEL NUMBER NOMENCLATURE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 4 8 T C D A 0 4 A 1 A 5 A 0 A 0 Unit Heat Type 48 = Cooling /Gas Heat RTU Tier / Model TC = Entry tier (with Puron refrigerant) Heat Size D = Low heat E = Medium heat F = High heat L = Low NOx, low heat M = Low NOx, medium heat N = Low NOx, high heat S = Stainless steel, low heat R = Stainless steel, medium heat T = Stainless steel, high heat Refrig. System Options A = Standard 1 -stage cooling B = Standard 1 -stage cooling w /Humidi -MiZer D = 2 -stg. cooling comp. w /NOVATION'" coil Cooling Tons 04 = 3 Ton 05 = 4 Ton 06 = 5 Ton 07 = 6 Ton 08 = 7.5 Ton 09 = 8.5 Ton 12 =10Ton 14 = 12.5 Ton Sensor Options A = None B = RA smoke detector C = SA smoke detector D = RA & SA smoke detector E = CO2 sensor F = RA smoke detector & CO2 G = SA smoke detector & CO2 H = RA & SA smoke detector & CO2 Indoor Fan Options 1 = Standard static option 2 = Medium static option 3 = High static option 4 Brand / Packaging 0 = Standard 1 = LTL Electrical Options A = None C = Non -fused disc D = Thru the base F = Non -fused & thru the base Service Options 0 = None 1 = Unpowered convenience outlet 2 = Powered convenience outlet Intake / Exhaust Options A = None B = Temp econo w/ baro relief F = Enthalpy econo w/ baro relief K = 2- Position damper Base Unit Controls 0 = Electromechanical 1 = PremierLink DDC controller 2 = RTU -MP multi protocol controller Design Rev Factory assigned Voltage 1 = 575/3/60 3 = 208 - 230/1/60 5 = 208 - 230/3/60 6 = 460/3/60 1 -Stage Cooling Coil Options (Outdoor - Indoor) A = Al /Cu - Al /Cu B = Precoat Al /Cu - AI /Cu C = E coat Al /Cu - AI /Cu D = E coat Al /Cu - E coat Al /Cu E = Cu /Cu - Al /Cu F = Cu /Cu - Cu /Cu M = Al /Cu -Al /Cu - Louvered Hail Guards N = Precoat Al /Cu - Al /Cu - Louvered Hail Guards P = E coat Al /Cu - Al /Cu - Louvered Hail Guards O = E coat Al /Cu - E coat Al /Cu - Louvered Hail Guards R = Cu /Cu - Al /Cu - Louvered Hail Guards S = Cu /Cu - Cu /Cu - Louvered Hail Guards 2 -Stage Cooling Coil Options (Outdoor - Indoor) G = AI /AI - Al /Cu H = Al /AI - Cu /Cu J = Al /AI - E -coat Al /Cu K = E -coat AI /AI - Al /Cu L = E -coat AI /AI - E -coat Al /Cu T = AI /AI - Al /Cu - Louvered Hail Guards U = Al /AI - Cu /Cu - Louvered Hail Guards V = AI /AI - E -coat Al /Cu - Louvered Hail Guards W = E -coat Al /AI - Al /Cu - Louvered Hail Guards X = E -coat AI /AI - E -coat Al /Cu - Louvered Hail Guards U co TABLE 2 - ARI COOLING RATING TABLE 1 -STAGE COOLING UNIT COOLING STAGES NOM. CAPACITY (TONS) NET COOLING CAPACITY (MBH) TOTAL POWER (KW) SEER EER IPLV A04 1 3 34.6 3.1 13.00 11.00 N/A A05 7 1 4 45.0 4.0 13.00 11.00 N/A A06 1 5 59.0 5.5 13.00 10.75 N/A A07 1 6 70.0 6.4 N/A 11.00 N/A A08 1 7.5 88.0 8.0 N/A 11.00 N/A A09 1 8.5 97.0 8.8 N/A 11.00 N/A Al2 1 10 117.0 10.6 N/A 11.00 N/A TABLE 3 - ARI COOLING RATING TABLE 2 -STAGE COOLING UNIT COOLING STAGES NOM. CAPACITY (TONS) NET COOLING CAPACITY (MBH) TOTAL POWER (KW) SEER EER IPLV D08 D12 D14 2 2 2 7.5 10 12.5 83.0 114.0 140.0 7.5 10.3 12.9 N/A N/A N/A 11.00 11.10 10.80 12.0 12.2 11.4 LEGEND ARI - Air Conditioning, Heating and Refrigeration Institute Test Standard ASHRAE - American Society of Heating, Refrigerating and Air Conditioning, Inc. EER - Energy Efficiency Ratio IPLV - Integrated Part Load Value SEER - Seasonal Energy Efficiency Ratio ARI Standard 210/240 UAC US ARI Standard 340/360 �pSHR � i3. COMPLIA�NTf This product has been designed and manufactured to meet Energy Star ethane for energy efficiency. However. proper refrigerant charge and proper air flow are critical to achieve rated capacity and efficiency. Installation of this product should follow all manufacturers refrigerant charging and air 11010 instructions. Fagure to confirm proper charge and air flow may reduce energy efficiency and Morten equipment IMa. 8 NOTES: 1. Rated and certified under ARI Standard 210/240 -06 or 340/360 -07, as appropriate. 2. Ratings are based on: Cooling Standard: 80 °F (27 °C) db, 67 °F (19 °C) wb indoor air temp and 95 °F (35 °C) db outdoor air temp. IPLV Standard: 80 °F (27 °C) db, 67 °F (19 °C) wb indoor air temp and 80 °F (27 °C) db outdoor air temp. 3. All 48TC units comply with ASHRAE 90.1 2001, 2004 Energy Standard for minimum SEER and EER requirements. 4. 48TC units comply with US Energy Policy Act (2005). To evaluate code compliance requirements, refer to state and local codes or visit the following website: http://bcap-energy.org. TABLE 4 - HEATING RATING TABLE - NATURAL GAS & PROPANE Units Gas Heat AL/SS HEAT EXCHANGER TEMP RISE (DEG F) THERMAL EFFICIENCY 06) AFUE ( %) INPUT / OUTPUT STAGE 1 (MBH) INPUT / OUTPUT STAGE 2 (MBH) LOW - 72 / 59 25 - 55 82% 81% 04 MED - 115 / 93 55 - 85 80% 80% HIGH - - - - - LOW - 72 / 59 25 - 55 82% 81% e P 05 MED - 115 / 93 35 - 65 81% 80% HIGH - 150 / 120 50 - 80 80% 80% LOW - 72 / 59 20 - 55 82% 81% 06 MED - 115 / 93 30 - 65 81% 80% HIGH - 150 / 120 40 - 80 80% 80% Three Phase V LOW - 72 / 59 25 - 55 82% N/A 04 MED 82 / 66 115 / 93 55 - 85 80% N/A HIGH - - - - - LOW - 72 / 59 25 - 55 82% N/A 05 MED - 115 / 93 35 - 65 81% N/A HIGH 120 / 96 150 / 120 50 - 80 80% N/A LOW - 72 / 59 20 - 55 82% N/A 06 MED - 115 / 93 30 - 65 81% N/A HIGH 120 / 96 150 / 120 40 - 80 80% N/A LOW - 72 / 59 15 - 55 82% N/A 07 MED - 115 / 93 25 - 65 81% N/A HIGH 120 / 96 150 / 120 35 - 80 80% N/A LOW - 125 / 103 20 - 50 82% N/A 08 MED 120 / 98 180 / 148 35 - 65 82% N/A HIGH 180 / 147 224 / 184 45 - 75 82% N/A LOW - 125 / 103 20 - 50 82% N/A 09 MED 120 / 98 180 / 148 30 - 65 82% N/A HIGH 180 / 147 224 / 184 40 - 75 82% N/A LOW 120 / 98 180 / 148 25 - 65 82% N/A 12 MED 180 / 147 224 / 184 30 - 65 82% N/A HIGH 200 / 160 250 / 205 35 - 70 80% N/A LOW 120 / 98 180 / 148 20 - 65 82% N/A 14 MED 180 / 147 224 / 184 25 - 65 82% N/A HIGH 200 / 160 250 / 205 25 - 70 80% N/A 11t,: Heat ratings are for natural gas heat exchangers operated at or below 2000 ft (610 m). For information on Propane or alti- tudes above 2000 ft (610 m), see the Application Data section of this book. Accessory Propane /High Altitude kits are also available. In the USA the input rating for altitudes above 2000 ft (610m) must be derated by 4% for each 1000 ft (305 m) above sea level. In Canada, the input rating must be derated by 10% for altitudes of 2000 ft (610 m) to 4500 ft (1372 m) above sea level. 9 U H v TABLE 5 - HEATING RATING TABLE - LOW NOx' UNIT GAS HEAT LOW NOx HEAT EXCHANGER TEMP RISE (DEG F) THERMAL EFFICIENCY (96) AFUE (%) INPUT / OUTPUT STAGE 1 (MBH) INPUT / OUTPUT STAGE 2 (MBH) 1000 2000 LOW - 60 / 50 20 - 50 81% 80% 80 04 MED - 90 / 74 30 - 60 81% 81% 63.9 A05 HIGH - - - - - 76.5 71.1 LOW - 60 / 50 20 - 50 81% 80% le F 05 MED - 90/74 30 -60 81% 81% 1 78 HIGH - 120 / 101 40 - 70 81% 80% 66.3 62.7 LOW - 60 / 50 15 - 50 81% 80% 79.4 06 MED - 90 / 74 25 - 60 80% 81% 85.8 84.3 HIGH - 120 / 101 35 - 70 80% 81% Three Phase 1 7 LOW - 60 / 50 20 - 50 81% 80% 04 MED - 90 / 74 30 - 60 81% 81% 85.0 HIGH - - - - - D12 LOW - 60 / 50 20 - 50 81 % 80% 05 MED - 90/74 30 -60 81% 81% 87.0 HIGH - 120 / 101 40 - 70 81% 80% 72.9 LOW - 60 / 50 15 - 50 81 % 80% 06 MED - 90 / 74 25 - 60 80% 81% HIGH - 120 / 101 35 - 70 80% 81% NOTE: 1. Units meet California's South Coast Air Quality Management District (SCAQMD) Low -NOx emissions requirement of 40 nanograms per joule or less. TABLE 6 - SOUND PERFORMANCE TABLE UNIT COOLING OUTDOOR SOUND (dB) A- WEIGHTED 63 125 250 500 1000 2000 4000 8000 STAGES A04 1 80 90.6 80.9 80.2 76 74.6 71.3 68.5 63.9 A05 1 81 90.9 84.6 79.5 77.9 76.5 71.1 66.9 62.5 A06 1 78 84.0 82.2 76.3 74.8 72.5 68.8 65.6 61.8 A07 1 78 88.8 81.8 76.9 74.4 73.3 69.8 66.3 62.7 A08 1 82 90.1 82.6 81.0 79.4 77.0 73.0 70.4 66.7 D08 2 82 85.8 84.3 80.5 78.7 76.4 72.7 68.3 65.1 A09 1 83 91.2 86.4 81.9 81.0 78.3 73.9 71.4 67.3 Al2 1 82 88.6 85.0 81.6 79.5 77.4 74.1 71.0 66.3 D12 2 82 89.0 83.1 80.5 78.5 75.5 71.6 69.6 69.3 D14 2 87 87.0 85.2 84.6 84.9 82.2 78.4 75.3 72.9 LEGEND dB - Decibel NOTES: 1. Outdoor sound data is measure in accordance with ARI standard 270 -2008. 2. Measurements are expressed in terms of sound power. Do not compare these values to sound pressure values because sound pressure depends on specific environ- mental factors which normally do not match individual applications. Sound power values are independent of the environment and therefore more accurate. 3. A- weighted sound ratings filter out very high and very low frequencies, to better approximate the response of "average" human ear. A- weighted measurements for Carrier units are taken in accordance with ARI standard 270 -2008. 10 TABLE 7 - MINIMUM - MAXIMUM AIRFLOW RATINGS - NATURAL GAS & PROPANE U UNIT HEAT LEVEL COOLING HEATING MINIMUM MAXIMUM MINIMUM MAXIMUM LOW 990 2190 48TC * *04 MED 900 1500 1000 1550 7 HIGH - - LOW 990 2190 48TC * *05 MED 1200 2000 1330 2460 HIGH 1390 2220 LOW 990 2730 48TC * *06 MED 1500 2500 1330 2880 HIGH 1390 2780 LOW 990 3640 48TC * *07 MED 1800 3000 1330 3450 HIGH 1390 3170 LOW 1900 4750 48TC * *08 MED 2250 3750 2100 3900 HIGH 2270 3780 LOW 1900 4750 48TC * *09 MED 2550 4250 2100 4560 HIGH 2270 4250 LOW 2100 5470 48TC * *12 MED 3000 5000 2620 5670 HIGH 2650 5290 LOW 2100 6830 48TC * *14 MED 3600 6000 2620 6800 HIGH 2650 7410 11 U 1- co TABLE 8 - PHYSICAL DATA (COOLING) 3 - 6 TONS Refrigeration System # Circuits / # Comp. / Type Purone refrig. (R -410A) charge per circuit A/B (Ibs -oz) Operating charge (Ibs -oz) - Humidi -MiZer Unit Metering Device High - press. Trip / Reset (psig) Low - press. Trip / Reset (psig) 48TC *A04 48TC *A05 48TC *A06 48TC *A07 1 / 1 / Scroll 5 -10 / - 8 -12 Acutrol 630 / 505 54 / 117 1 / 1 / Scroll 8 -8 / - 14 -13 Acutrol 630 / 505 54 / 117 1 / 1 / Scroll 10 -11 / - 16 -0 Acutrol 630 / 505 54 / 117 1 / 1 / Scroll 14 -2 / - 22 -4 Acutrol 630 / 505 54 / 117 Evap. Coll Material Coil type Rows /FPI Total Face Area (ft2) Condensate Drain Conn. Size Cu / Al 3/8" RTPF 2/15 5.5 3/4" Cu / Al 3/8" RTPF 2/15 5.5 3/4" Cu / Al 3/8" RTPF 4/15 5.5 3/4" Cu / Al 3/8" RTPF 4/15 7.3 3/4" Evap. Fan and Motor Motor Qty / Drive Type Max BHP RPM Range Motor Frame Size Fan Qty / Type Fan Diameter (in) Motor Qty / Drive Type Max BHP RPM Range Motor Frame Size Fan Qty / Type Fan Diameter (in) Motor Qty / Drive Type Max BHP RPM Range Motor Frame Size Fan Qty / Type Fan Diameter (in) Motor Qty / Drive Type Max BHP RPM Range Motor Frame Size Fan Qty / Type Fan Diameter (in) Motor Qty / Drive Type Max BHP RPM Range Motor Frame Size Fan Oty / Type Fan Diameter (in) 1 / Belt 1.2 560 -854 48 1 / Centrifugal 10 x 10 1 / Belt 1.2 770 -1175 48 1 / Centrifugal 10 x 10 1 / Belt 1.2 560 -854 48 1 / Centrifugal 10 x 10 1 / Belt 1.2 770 -1175 48 1 / Centrifugal 10 x 10 1 / Belt 2.4 1035 -1466 56 1 / Centrifugal 10 x 10 1 / Belt 1.2 560 -854 48 1 / Centrifugal 10 x 10 1 / Belt 1.2 770 -1175 48 1 / Centrifugal 10 x 10 1 / Belt 1.2 560 -854 48 1 / Centrifugal 10 x 10 1 / Belt 1.2 770 -1175 48 1 / Centrifugal 10 x 10 1 / Belt 2.4 1035 -1466 56 1 / Centrifugal 10x 10 1 / Belt 1.2 770 -1175 48 1 / Centrifugal 10 x 10 1 / Belt 1.5 1035 -1466 56 1 / Centrifugal 10 x 10 1 / Belt 1.5 770 -1175 48 1 / Centrifugal 10x 10 1 / Belt 2.4 1035 -1466 56 1 / Centrifugal 10 x 10 1 / Belt 2.9 1303 -1687 56 1 / Centrifugal 10 x 10 - - - - - - - - - - - - 1 / Belt 2.4 1073 -1457 56 1 / Centrifugal 10 x 10 1 / Belt 2.9* 1173 -1518 56 1 / Centrifugal 10 x 10 1 / Belt 3.7 1474 -1788 56 1 / Centrifugal 10x 10 Standard Static 1 phase Medium Static 1 phase Standard Static 3 phase Medium Static 3 phase High Static 3 phase Cond. Coil Material Coil type Rows /FPI Total Face Area (ft2) Cu / Al 3/8" RTPF 1/17 14.6 Cu / Al 3/8' RTPF 2/17 16.5 Cu / Al 3/8" RTPF 2/17 16.5 Cu / Al 3/8" RTPF 2/17 21.3 Humidi - MiZer Coil Material Rows..Fins /in. Total Face Area (ft2) Cu / Al 1 / 17 3.9 Cu / Al 2 / 17 3.9 Cu / Al 2 / 17 3.9 Cu / Al 2 / 17 5.2 Cond. fan / motor Qty / Motor Drive Type Motor HP / RPM Fan diameter (in) 1/ Direct 1/4 / 1100 22 1/ Direct 1/4 / 1100 22 1/ Direct 1/4 / 1100 22 1/ Direct 1/4 / 1100 22 Filters RA Filter # / Size (in) OA inlet screen # / Size (in) 2/16x25x2 1/20x24x1 2/16x25x2 1/20x24x1 2/16x25x2 1/20x24x1 4/16x16x2 1/20x24x1 * 575V motor utilizes 3.7 BHP. 12 TABLE 9 - PHYSICAL DATA (HEATING) 3 - 6 TONS Gas Connection # of Gas Valves Nat. gas supply line press (in. w.g.) /(PSIG) Propane supply line press (in. w.g.) /(PSIG) Heat Anticipator Setting (Amps) 1st stage 2nd stage 48TC * *04 48TC * *05 48TC * *06 48TC * *07 1 4 -13 / 0.18 - 0.47 11 -13 / 0.40 - 0.47 0.14 0.14 1 4 -13 / 0.18 - 0.47 11 -13 / 0.40 - 0.47 0.14 0.14 1 4 -13 / 0.18 - 0.47 11 -13 / 0.40 - 0.47 0.14 0.14 1 4 -13 / 0.18 - 0.47 11 -13 / 0.40 - 0.47 0.14 0.14 Natural 0 J 0 I _ 0 = Gas, Propane Heat # of stages / # of burners (total) Connection size Rollout switch opens / closes Temperature rise range (F) # of stages / # of burners (total) Connection size Rollout switch opens / closes Temperature rise range (F) Connection size # of stages / # of burners (total) Rollout switch opens / closes Temperature rise range (F) 1 / 2 1/2" NPT 195 / 115 25 - 55 1 or 2 / 3 1/2" NPT 195 / 115 55 - 85 - - - - 1 / 2 1/2" NPT 195 / 115 25 - 55 1 / 3 1/2" NPT 195 / 115 35 - 65 1 or 2 / 3 1/2" NPT 195 / 115 50 - 80 1 / 2 1/2" NPT 195 / 115 20 - 55 1 / 3 1/2" NPT 195 / 115 30 - 65 1 or 2 / 3 1/2" NPT 195 / 115 40 - 80 1 / 2 1/2" NPT 195 / 115 15 - 55 1 / 3 1/2" NPT 195 / 115 25 - 65 1 or 2 / 3 1/2" NPT 195 / 115 35 - 80 Low O CI W = 0 = NO Gas Heat # of stages / # of burners (total) Connection size Rollout switch opens / closes Temperature rise range (F) # of stages / # of burners (total) Connection size Rollout switch opens / closes Temperature rise range (F) # of stages / # of burners (total) Connection size Rollout switch opens / closes Temperature rise range (F) 1 / 2 1/2" NPT 195 / 115 20 - 50 1 / 3 1/2" NPT 195 / 115 30 - 60 - - - - 1 / 2 1/2" NPT 195 / 115 20 - 50 1 / 3 1/2" NPT 195 / 115 30 - 60 1 / 3 1/2" NPT 195 / 115 40 - 70 1 / 2 1/2" NPT 195 / 115 15 - 50 1 / 3 1/2" NPT 195 / 115 25 - 60 1 / 3 1/2" NPT 195 / 115 35 - 70 - - - - - - - - - - - - 13 CURBS & WEIGHTS DIMENSIONS - CHASSIS 1 NOTES: 1. DIMENSIONS ARE IN INCHES DIMENSIONS IN ( ) ARE IN MILLIMETERS. 2. S CENTER OF GRAVITY 3. DIRECTION OF AIR FLOW 44 321/4 [8181 33 3/8 [6481 18/81 1 } [459] 1 [3631 ( 16-1/8 14-1/4 (312]4 [41111 1 -*10-1/2.- 1265] T 11-3 /81 12891 6-1/8 11551 E STD. — CONDENSATE DRAIN 16 -3/4 1427) SUPPLY AIR 25-1/8 16381 RETURN AIR 1 -1/4 1321 SEE THRU THE BASE CHART ECONOMIZER HOOD (OPTIONAL) 16 [4061 25-5/8 [652] RETURN AIR 10 -7/8 [277] E ALT. CONDENSATE DRAIN OPENIN6 IN BASEPAN 17 -3/4 [4511 SUPPLY AIR 6 -1/4 [151 1 — 6 -5/8 !1681 8. 1 26 3/4 16811 1177] SUPPLY 4 AIR 31 1// 1793) *RIGH 1. 6 [152] BAROMETRIC RELIEF FLOW RETURN AIR 1-5/8 11181 IECTRICAL DISCONNECT LOCATION OPTIONAL FACTORY INSTALLED CONVENIENCE OUTLET 19 -1/2 6-5/8 [1681 3 -3/4 195) 16 3/4 FT 25 16361 OPTIONAL FACTORY INSTALLED DISCONNECT ` --FLUE [1001 HOOD TOP RETURN AIR 26-1/2 29 -3/8 [6731 [1171 - 3 -3/8 12 -1/8 [ 307 ] 18 1/2 [4101 [85) SUPPLY AIR HANDLE 30 1/8 17611 4 3/8 18881 FRONT 8 -3/8 (213] FILTER ACCESS PANEL (TOOL -LESS) • CONNECTION SIZES A 1 3/8' DIA (35] FIELD POWER SUPPLY HOLE B 2' [50) DIA POWER SUPPLY KNOCKOUT C 1 3/4' DIA [51] GAUGE ACCESS PLUG D 1/8" DIA [22] FIELD CONTROL WIRING HOLE E 3/4 " -14 NPT CONDENSATE DRAIN F 1/2 "-14 NPT GAS CONNECTION 6 2 1/2 ' DIA [64] POWER SUPPLY KNOCK -OUT 25 16361 OPTIONAL FACTORY INSTALLED DISCONNECT ` --FLUE [1001 HOOD TOP RETURN AIR 26-1/2 29 -3/8 [6731 [1171 - 3 -3/8 12 -1/8 [ 307 ] 18 1/2 [4101 [85) SUPPLY AIR HANDLE 30 1/8 17611 4 3/8 18881 FRONT 8 -3/8 (213] FILTER ACCESS PANEL (TOOL -LESS) • • COMP. • ACCESS PANEL ' a - CONDENSER INDOOR COIL ACCESS PANEL 1 1/2' ACC. 7/8" (22.2) X THRU-THE-BASE CHART THESE HOLES REOUIRED FOR USE CRBTMPWR001A01, 003A01 J THREADED CONDUIT SIZE WIRE USE REVD HOLE SIZES (MAX.) W 1/2' ACC. 7/8" (22.2) X 1/2' 24V 1/8' (22.2) Y 4 3/4' (001,003) POWER 1 1/8' (28.4) 200 (003) 1/2' FPT GAS 1 3/16" (30.0) FOR 'THRU- THE - BASEPAN' FACTORY OPTION, FITTINGS FOR ONLY X,Y, 6 Z ARE PROVIDED 4 SELECT EITHER 3/4" OR 1/2" FOR POWER, DEPENDING ON WIRE SIZE f4 (001) PROVIDES 3/4" FPT THRU CURB FLANGE 6 FITTING. Fig. 1 - Dimensions 48TC 04 -07 16 BACK 2 -5/8 [671 TYP CURB WIDTH UNIT J K 48TC 404 33 3/8 [841] 18 5/8 [412] 48TC 405 33 3/8 [847] 14 7/8 [311] 48TC 406 33 3/8 [841] 14 7/8 [317] 48TC 401 41 3/8 [1051] 14 7/8 [377] C08517 CURBS & WEIGHTS DIMENSIONS - CHASSIS 1 (cont.) UNIT STD. UNIT WEIGHT CORNER WEIGHT (Al CORNER WEIGHT (B) CORNER WEIGHT (C1 CORNER WEIGHT ID) 13 C.G. Surface behind servicer is grounded (e.g., metal, masonry wall) Surface behind servicer is electrically non - conductive (e.g., wood, fiberglass) Check for sources of flue products within 10 -ft of unit fresh air intake hood HEIGHT LBS. KG. LBS. KG. LBS. KG. LBS. KG. LBS. KG. X Y Z 48TC -A04 483 219 111 50 125 57 131 59 116 53 39 [991] 23 [584) 16 3/8 [416] 48TC-A05 531 244 124 56 139 63 145 66 129 59 39 [991] 23 [584] 17 [432) 48TC-A06 569 258 131 59 141 67 154 10 137 62 39 [991] 23 [584) 17 1/4 [438) 48TC -A07 652 296 150 68 169 76 176 80 157 11 39 [991] 23 [584] 20 1/8 [511) 0' -3" [76] TOP 0'_3" [763 dl (11] (BOLT HEADS) SUPPLY AIR OPENING RETURN AI OPENING 0' -0 7/16" [11] (BOLT HEADS) 11' -7 13V16" 1 /6" [504) [3343 0' -3 "� [76) 3' -D" [914] Fig. 3 - Curb Dimensions CORNER B 11{ «10 0 CORNER C 0 `t. .1 : 00r J FRONT C08593 Fig. 2 - Dimensions 48TC 04 -07 2 " -7 5/8" [8033 0' -0 7/16" (11] (BOLT HEADS) 0' -0 7/16" [113 (BOLT HEADS) C07458 GASKET SUPPLIED WITH CURB) NAIL COUNTER FLASHING FIELD SUPPLIED) /ROOFING FELT (FIELD SUPPLIED) CANT STRIP Ar FIELD SUPPLIED) ROOFING FELT (FIELD SUPPLIED) C07457 Fig. 4 - Curb Installation Detail (Typical) Fig. 5 - Service Clearance C08337 LOC DIMENSION CONDITION A 48" (1219 mm) 18" (457 mm) 18" (457 mm) 12" (305 mm) Unit disconnect is mounted on panel No disconnect, convenience outlet option Recommended service clearance Minimum clearance 13 42" (1067 mm) 36" (914 mm) Special Surface behind servicer is grounded (e.g., metal, masonry wall) Surface behind servicer is electrically non - conductive (e.g., wood, fiberglass) Check for sources of flue products within 10 -ft of unit fresh air intake hood C 36" (914 mm) 18" (457 mm) Side condensate drain is used Minimum clearance D 48" (1219 mm) 42" (1067 mm) 36" (914 mm) Special No flue discharge accessory installed, surface is combustible material Surface behind servicer is grounded (e.g., metal, masonry wall, another unit) Surface behind servicer is electrically non - conductive (e.g., wood, fiberglass) Check for adjacent units or building fresh air intakes within 10 -ft of this unit's flue outlet 17 U 1- TABLE 12 - COOLING CAPACITIES 1 -STAGE COOLING 3 TONS 48TC•A04 AMBIENT TEMPERATURE 85 95 105 115 EAT (db) EAT (db) EAT (db) EAT (db) 75 80 85 75 80 85 75 80 85 75 80 85 TC 28.1 28.1 31.7 26.3 26.3 29.8 24.5 24.5 27.7 22.6 22.6 25.5 58 SHC 24.4 28.1 31.7 22.9 26.3 29.8 21.3 24.5 27.7 19.6 22.6 25.5 TC 30.3 30.3 31.0 27.8 27.8 29.8 25.1 25.1 28.4 22.6 22.6 26.5 62 SHC 22.6 26.8 31.0 21.5 25.7 29.8 20.2 24.3 28.4 18.7 22.6 26.5 TC 35.5 35.5 35.5 33.1 33.1 33.1 30.5 30.5 30.5 27.5 27.5 27.5 )00 AT 67 SHC 19.5 23.7 27.9 18.5 22.7 26.9 17.4 21.6 25.8 16.2 20.4 24.6 TC 39.0 39.0 39.0 37.1 37.1 37.1 35.1 35.1 35.1 32.7 32.7 32.7 72 SHC 15.3 19.5 23.7 14.5 18.8 23.0 13.7 17.9 22.2 12.9 17.1 21.3 TC - 41.4 41.4 - 39.6 39.6 - 37.6 37.6 - 35.4 35.4 76 SHC - 16.0 21.0 - 15.4 20.2 - 14.6 19.3 - 13.8 18.3 TC 30.2 30.2 34.2 28.4 28.4 32.2 26.5 26.5 30.0 24.5 24.5 27.7 58 SHC 26.3 30.2 34.2 24.7 28.4 32.2 23.1 26.5 30.0 21.3 24.5 27.7 TC 31.9 31.9 34.2 29.4 29.4 32.8 26.7 26.7 31.2 24.5 24.5 28.8 62 SHC 24.6 29.4 34.2 23.4 28.1 32.8 22.0 26.6 31.2 20.3 24.5 28.8 TC 36.7 36.7 36.7 34.8 34.8 34.8 32.2 32.2 32.2 29.1 29.1 29.1 050 ATE 67 SHC 20.6 25.4 30.2 19.8 24.6 29.4 18.8 23.6 28.4 17.6 22.4 27.2 TC 40.1 40.1 40.1 38.2 38.2 38.2 36.1 36.1 36.1 33.7 33.7 33.7 72 SHC 15.7 20.5 25.3 15.0 19.8 24.6 14.2 19.0 23.8 13.4 18.2 23.0 TC - 42.4 42.4 - 40.6 40.6 - 38.5 38.5 - 36.2 36.2 76 SHC - 16.6 22.2 - 15.9 21.3 - 15.2 20.4 - 14.4 19.5 TC 32.2 32.2 36.4 30.4 30.4 34.3 28.4 28.4 32.1 26.3 26.3 29.7 58 SHC 28.0 32.2 36.4 26.4 30.4 34.3 24.7 28.4 32.1 22.8 26.3 29.7 TC 33.3 33.3 37.0 30.8 30.8 35.5 28.4 28.4 33.4 26.3 26.3 30.9 62 SHC 26.4 31.7 37.0 25.1 30.3 35.5 23.4 28.4 33.4 21.7 26.3 30.9 TC 37.7 37.7 37.7 35.6 35.6 35.6 33.4 33.4 33.4 30.4 30.4 30.4 200 AT 67 SHC 21.7 27.0 32.4 20.9 26.3 31.6 20.0 25.4 30.8 18.8 24.2 29.6 TC 40.9 40.9 40.9 39.0 39.0 39.0 36.9 36.9 36.9 34.4 34.4 34.4 72 SHC 16.1 21.5 26.8 15.4 20.8 26.1 14.7 20.0 25.4 13.8 19.2 24.5 TC - 43.1 43.1 - 41.3 41.3 - 39.1 39.1 - 36.8 36.8 76 SHC - 17.1 23.1 - 16.4 22.3 - 15.7 21.4 - 14.9 20.5 TC - - - 32.1 32.1 36.3 30.0 30.0 34.0 27.9 27.9 31.5 58 SHC - - - 27.9 32.1 36.3 26.1 30.0 34.0 24.2 27.9 31.5 TC 28.4 28.4 30.5 32.2 32.2 37.8 30.1 30.1 35.3 27.9 27.9 32.8 62 SHC 17.6 24.1 30.5 26.6 32.2 37.8 24.8 30.1 35.3 23.0 27.9 32.8 TC 33.2 33.2 33.2 36.4 36.4 36.4 34.1 34.1 34.1 31.5 31.5 32.0 350 AT 67 SHC 15.0 21.4 27.9 21.9 27.8 33.7 21.0 26.9 32.9 20.0 26.0 32.0 TC 37.5 37.5 37.5 39.7 39.7 39.7 37.5 37.5 37.5 35.0 35.0 35.0 72 SHC 11.8 18.3 24.8 15.8 21.7 27.5 15.0 20.9 26.8 14.2 20.1 26.0 TC - 40.1 40.1 - 41.8 41.8 - 39.6 39.6 - 37.3 37.3 76 SHC - 15.3 22.7 - 16.8 23.2 - 16.1 22.3 - 15.3 21.5 EAT (wb) TC 28.1 28.1 34.2 33.7 33.7 38.1 31.6 31.6 35.7 29.3 29.3 33.2 58 SHC 21.9 28.1 34.2 29.3 33.7 38.1 27.4 31.6 35.7 25.5 29.3 33.2 TC 30.3 30.3 33.8 33.7 33.7 39.6 31.6 31.6 37.1 29.4 29.4 34.5 62 SHC 19.8 26.8 33.8 27.8 33.7 39.6 26.1 31.6 37.1 24.2 29.4 34.5 TC 35.5 35.5 35.5 36.9 36.9 36.9 34.6 34.6 34.9 32.0 32.0 34.0 500 67 SHC 16.7 23.7 30.7 22.8 29.2 35.7 21.9 28.4 34.9 21.0 27.5 34.0 TC 39.0 39.0 39.0 40.2 40.2 40.2 38.0 38.0 38.0 35.5 35.5 35.5 72 SHC 12.4 19.5 26.6 16.1 22.5 28.8 15.4 21.7 28.1 14.6 21.0 27.4 TC - 41.4 41.4 - 42.2 42.2 - 40.0 40.0 - - - 76 SHC - 16.0 24.3 - 17.2 24.0 - 16.5 23.2 - - - LEGEND: - Do not operate Cfm - Cubic feet per minute (supply air) EAT(db) - Entering air temperature (dry bulb) EAT(wb) - Entering air temperature (wet bulb) SHC - Sensible heat capacity TC - Total capacity 25 U H o TABLE 25 - 48TC * *04 FAN PERFORMANCE (cont.) 3 PHASE 3 TON HORIZONTAL SUPPLY CFM AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 0.2 0.2 0.4 0.6 1.6 1.8 0.8 2.0 1.0 RPM RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP Field- Supplied Drive' Medium Static Option Standard Static Option High Static Option 900 Medium Static Option 1019 900 553 0.14 681 0.22 782 0.32 870 0.42 948 0.53 975 575 0.16 700 0.25 801 0.35 888 0.46 965 0.57 1050 597 0.18 720 0.28 820 0.38 906 0.49 983 0.61 1125 620 0.21 741 0.31 839 0.42 925 0.54 1001 0.66 1200 643 0.23 762 0.34 859 0.46 944 0.58 1020 0.71 1275 667 0.27 783 0.38 879 0.50 963 0.63 1038 0.76 1350 691 0.30 805 0.42 900 0.55 983 0.68 1057 0.82 1425 715 0.34 827 0.47 920 0.60 1002 0.74 1076 0.88 1500 740 0.38 849 0.52 941 0.66 1023 0.80 1096 0.95 CFM AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 1.2 0.2 1.4 0.4 1.6 1.8 2.0 1.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP Field - Supplied Drivel Medium Static Option Medium Static Option High Static Option 900 900 1019 0.64 1084 0.76 1146 0.89 1203 1.02 1258 1.16 975 1036 0.69 1101 0.81 1162 0.94 1219 1.08 1274 1.22 1050 1053 0.74 1118 0.86 1179 1.00 1236 1.14 1290 1.28 1125 1071 0.79 1135 0.92 1196 1.06 1253 1.20 1307 1.35 1200 1089 0.84 1153 0.98 1213 1.12 1270 1.27 1324 1.42 1275 1107 0.90 1171 1.04 1231 1.19 1287 1.34 1341 1.50 1350 1126 0.96 1189 1.11 1249 1.26 1305 1.42 1358 1.58 1425 1144 1.03 1208 1.18 1267 1.34 1323 1.50 1376 1.66 1500 1163 1.10 1226 1.25 1285 1.41 1341 1.58 1394 1.75 NOTE: For more information, see General Fan Performance Notes on page 35. 1. Recommend using field - supplied drive (part no. KR11AG006) and belt (part no. KR3OAE039) TABLE 26 - 48TC * *04 3 PHASE 3 TON VERTICAL SUPPLY CFM AVAILABLE EXTERNAL STATIC PRESSURE (In. wg) 0.2 0.4 0.6 0.8 1.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP Field - Supplied Drivel Standard Static Option Medium Static Option 900 567 0.15 688 0.22 786 0.30 871 0.37 947 0.44 975 591 0.17 710 0.26 807 0.34 891 0.42 966 0.49 1050 615 0.20 732 0.29 828 0.38 911 0.47 985 0.55 1125 641 0.23 755 0.33 849 0.42 931 0.52 1005 0.61 1200 666 0.26 778 0.37 871 0.47 952 0.57 1025 0.67 1275 693 0.29 802 0.41 893 0.53 974 0.63 1046 0.74 1350 719 0.33 826 0.46 916 0.58 995 0.70 1067 0.81 1425 746 0.38 850 0.51 939 0.64 1017 0.76 1088 0.89 1500 773 0.42 875 0.57 963 0.70 1040 0.84 1110 0.96 AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) CFM 1.2 1.4 1.8 1.8 2.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP Medium Static Option High Static Option 900 1016 0.51 1080 0.57 1139 0.64 1195 0.71 1249 0.77 975 1034 0.57 1098 0.64 1157 0.72 1213 0.79 1266 0.86 1050 1053 0.63 1116 0.71 1176 0.79 1231 0.87 1284 0.95 1125 1073 0.70 1135 0.79 1194 0.87 1250 0.96 1302 1.04 1200 1093 0.77 1155 0.87 1213 0.96 1268 1.05 1321 1.14 1275 1113 0.85 1174 0.95 1232 1.05 1287 1.15 1339 1.25 1350 1133 0.92 1194 1.03 1252 1.14 1307 1.25 1358 1.35 1425 1154 1.01 1215 1.12 1272 1.24 1326 1.35 1378 1.46 1500 1175 1.09 1235 1.22 1292 1.34 1346 1.46 1397 1.58 NOTE: For more information, see General Fan Performance Notes on page 35. Boldface indicates field - supplied drive is required. 1. Recommend using field - supplied fan pulley (part no. KR11AG006) and belt (part no. KR30AE039). 41 TABLE 46 - 48TC *A04 ELECTRICAL INFORMATION 1 -STAGE COOLING 3 TONS V -Ph -Hz VOLTAGE RANGE COMP (ea) OFM (ea) IFM RLA LRA WATTS FLA TYPE Max WATTS Max AMP Draw EFF at Full Load FLA MIN MAX 208 -1 -60 187 253 16.6 79 325 1.5 Std Static 1000 5.1 70% 4.9 208-1-60 187 253 21.8 117 325 1.5 Med Static 1000 5.1 70% 4.9 230 -1 -60 187 253 21.8 117 325 1.5 Std Static 1000 5.1 70% 4.9 230 -1 -60 187 253 16.6 79 325 1.5 Med Static 1000 5.1 70% 4.9 Std Static 1000 5.1 70% 4.9 208 -3 -60 187 253 10.4 73 325 1.5 Med Static 1000 5.1 70% 4.9 High Static 2120 5.5 80% 5.2 Std Static 1000 5.1 70% 4.9 230 -3 -60 187 253 10.4 73 325 1.5 Med Static 1000 5.1 70% 4.9 High Static 2120 5.5 80% 5.2 Std Static 1000 2.2 70% 2.1 460 -3 -60 414 506 5.8 38 325 0.8 Med Static 1000 2.2 70% 2.1 High Static 2120 2.7 80% 2.6 Std Static 1000 2.0 71% 1.9 575 -3 -60 518 633 3.8 37 325 0.6 Med Static 1000 2.0 71% 1.9 High Static 2120 2.1 80% 2.0 TABLE 47 - 48TC *A05 1 -STAGE COOLING 4 TONS V -Ph -Hz VOLTAGE RANGE COMP (ea) OFM (ea) IFM RLA LRA WATTS FLA TYPE Max WATTS Max AMP Draw EFF at Full Load FLA MIN MAX 208 -1 -60 187 253 26.2 134 325 1.5 Std Static 1000 5.1 70% 4.9 208-1-60 187 253 21.8 117 325 1.5 Med Static 1850 7.4 78% 7.0 230 -1 -60 187 253 21.8 117 325 1.5 Std Static 1000 5.1 70% 4.9 230 -1 -60 187 253 26.2 134 325 1.5 Med Static 1850 7.4 78% 7.0 Std Static 1000 5.1 70% 4.9 208 -3 -60 187 253 13.7 83 325 1.5 Med Static 1000 5.1 70% 4.9 High Static 2120 5.5 80% 5.2 Std Static 1000 5.1 70% 4.9 230 -3 -60 187 253 13.7 83 325 1.5 Med Static 1000 5.1 70% 4.9 High Static 2120 5.5 80% 5.2 Std Static 1000 2.2 70% 2.1 460 -3 -60 414 506 6.2 41 325 0.8 Med Static 1000 2.2 70% 2.1 High Static 2120 2.7 80% 2.6 Std Static 1000 2.0 71% 1.9 575 -3 -60 518 633 4.8 37 325 0.6 Med Static 1000 2.2 71% 2.1 High Static 2120 2.1 80% 2.0 TABLE 48 - 48TC *A06 1 -STAGE COOLING 5 TONS V -Ph -Hz VOLTAGE RANGE COMP (ea) OFM (ea) IFM RLA LRA WATTS FLA TYPE Max WATTS Max AMP Draw EFF at Full Load FLA MIN MAX 208 -1 -60 187 253 26.2 134 325 1.5 Std Static 1000 5.1 70% 4.9 Med Static 1850 7.4 78% 7.0 Std Static 1000 5.1 70% 4.9 230 -1 -60 187 253 26.2 134 325 1.5 Med Static 1850 7.4 78% 7.0 Std Static 1000 5.1 70% 4.9 208 -3 -60 187 253 15.6 110 325 1.5 Med Static 2120 5.5 80% 5.2 High Static 2615 7.9 81% 7.5 Std Static 1000 5.1 70% 4.9 230 -3 -60 187 253 15.6 110 325 1.5 Med Static 2120 5.5 80% 5.2 High Static 2615 7.9 81% 7.5 Std Static 1000 2.2 70% 2.1 460 -3 -60 414 506 7.7 52 325 0.8 Med Static 2120 2.7 80% 2.6 High Static 2615 3.6 81% 3.4 Std Static 1000 2.0 71% 1.9 575 -3 -60 518 633 5.8 39 325 0.6 Med Static 1390 2.1 81% 2.0 High Static 3775 2.9 81% 2.8 53 . TABLE 56 - MCA/MOCP DETERMINATION NO C.O. OR UNPWRD C.O. 1- n NOM. V -Ph -Hz IFM TYPE COMBUSTION FAN MOTOR FLA POWER EXHAUST FLA NO C.O. or UNPWRD C.O. NO P.E. w/ P.E. (pwrd fr/ unit) MCA MOCP DISC. SIZE MCA MOCP DISC. SIZE FLA LRA FLA LRA STD 27.2 40.0 26 95 29.1 45.0 29 97 208/230 -1 -60 MED 0.48 1.9 27.2 40.0 26 95 29.1 45.0 29 97 STD 19.4 25.0 19 89 21.3 30.0 22 91 208/230 -3 -60 MED 0.48 1.9 19.4 25.0 19 89 21.3 30.0 22 91 HIGH 19.7 30.0 20 107 21.6 30.0 22 109 rc* STD 10.2 15.0 10 46 11.2 15.0 11 47 460 -3 -60 MED 0.25 1.0 10.2 15.0 10 46 11.2 15.0 11 47 HIGH 10.7 15.0 11 55 11.7 15.0 12 56 STD 7.3 15.0 7 44 9.2 15.0 9 46 575 -3 -60 MED 0.24 1.9 7.3 15.0 7 44 9.2 15.0 9 46 HIGH 7.4 15.0 7 50 9.3 15.0 10 52 STD 33.7 50.0 32 133 35.6 50.0 35 135 208/230 -1 -60 MED 0.48 1.9 33.7 50.0 32 133 35.6 50.0 35 135 STD 23.5 30.0 23 99 25.4 30.0 25 101 208/230 -3 -60 MED 0.48 1.9 23.5 30.0 23 99 25.4 30.0 25 101 HIGH 23.8 30.0 23 117 25.7 30.0 25 119 rc* STD 10.7 15.0 10 49 11.7 15.0 12 50 460 -3 -60 MED 0.25 1.0 10.7 15.0 10 49 11.7 15.0 12 50 HIGH 11.2 15.0 11 58 12.2 15.0 12 59 STD 8.5 15.0 8 44 10.4 15.0 11 46 575 -3 -60 MED 0.24 1.9 8.5 15.0 8 44 10.4 15.0 11 46 HIGH 8.6 15.0 9 50 10.5 15.0 11 52 208/230 STD 39.2 60.0 37 150 41.1 60.0 40 152 -1 -60 MED 0.48 1.9 41.3 60.0 40 175 43.2 60.0 42 177 STD 25.9 30.0 25 126 27.8 40.0 27 128 m 208/230 -3 -60 MED 0.48 1.9 26.2 40.0 26 144 28.1 40.0 28 146 Q HIGH 28.5 40.0 29 170 30.4 45.0 30 172 V STD 12.5 20.0 12 60 13.5 20.0 13 61 o 460 -3 -60 MED 0.25 1.0 13.0 20.0 13 69 14.0 20.0 14 70 HIGH 13.8 20.0 14 82 14.8 20.0 15 83 STD 9.8 15.0 10 46 11.7 15.0 12 48 575 -3 -60 MED 0.24 1.9 9.9 15.0 10 52 11.8 15.0 13 54 HIGH 10.7 15.0 11 63 12.6 15.0 13 65 STD 30.5 45 30 157 32.4 50 32 159 208/230 -3 -60 MED 0.48 1.9 32.8 50 32 183 34.7 50 34 185 HIGH 32.8 50 32 183 34.7 50 34 185 STD 15.5 25 15 79 16.5 25 16 80 rc* 460 -3 -60 MED 0.25 1.0 16.3 25 16 92 17.3 25 17 93 HIGH 17.3 25 17 101 18.3 25 18 102 STD 11.9 15 12 63 13.8 20 14 65 575 -3 -60 MED 0.24 1.9 12.7 20 12 74 14.6 20 15 76 HIGH 12.7 20 12 74 14.6 20 15 76 48TC *A08 STD 39.5 60 38 191 43.3 60 43 195 208/230 -3 -60 MED 0.48 3.8 41.8 60 41 228 45.6 60 45 232 HIGH 49.3 60 49 254 53.1 60 54 258 STD 19.5 30 19 113 21.3 30 21 115 460 -3 -60 MED 0.25 1.8 20.3 30 20 132 22.1 30 22 134 HIGH 24.3 30 24 145 26.1 30 26 147 STD 14.9 20 14 89 18.7 25 19 93 575 -3 -60 MED 0.24 3.8 15.3 20 15 104 19.1 25 19 108 HIGH 18.1 25 18 118 21.9 30 23 122 See notes on next page. 57 U co • • PER PLAN REVIEW /ROUTING SLIP . ,• ACTIVITY NUMBER: M11 -092 PROJECT NAME: SPEC EAST SITE ADDRESS: 12628 INTERURBAN AV S X Original Plan Submittal Response to Correction Letter # DATE: 07 -07 -11 Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: A3-- Al 7- r Building Division Public Works ❑ Aw\ N /A— Vl'L Fire Prevention Structural Planning Division Permit Coordinator El 1 DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete n DUE DATE: 07-12-11 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 08-09 -11 Approved ❑ Approved with Conditions W Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 Contractors or Tradespeople Priiter Friendly Page • General /Specialty Contractor A business registered as a construction contractor with L&l to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company IECS INC 2069399495 Po Box 19252 Seattle WA 981091252 King Corporation UBI No. 601639846 Status Active License No. IECS * * *044QL License Type Construction Contractor Effective Date 11/13/1996 Expiration Date 11/20/2012 Suspend Date Specialty 1 Specialty 2 Unused Heating /Vent /Air - Conditioning And Refrig (Hvac /R) Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status SEATTMI038NR SEATTLE MECHANICAL INC Construction Contractor Metal Fabrication Unused 8/19/1997 11 /4/2001 Archived Business Owner Information Name Role Effective Date Expiration Date HUMPHREY, GEORGE 01/01/1980 Bond Information No records found for the previous 6 year period Assignment of Savings Information Page 1 of 1 Savings Assignment of Savings Account Number Effective Date Release Date Assignment Type Impaired Date Amount Received Date 2 21221204 11/20/2001 Until Released Bond 56,000.00 11/20/2001 1 20736965 10/10/1996 3/4/2009 Bond 08/01/2010 $4,000.00 Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date WEST 12 AMERICAN INS BKW1153913555 08/01/2010 08/01/2011 $1,000,000.00 07/28/2010 CO LIBERTY 11 NORTHWEST BKW1053913555 08/01/2009 08/01/2010 $1,000,000.00 07/21/2009 INS CORP 10 FEDERAL MUTUAL INS CO 9821065 08/01/2007 08/01/2009 $1,000,000.00 06/26/2008 9 FEDERATED MUTUAL INS CO 5090561 08/01/2006 08/01/2007 $1,000,000.00 07/31/2006 8 OREGON AUTO INS CO C031557907 08/01/2005 08/01/2006 51,000,000.00 07/29/2005 7 AUTO NS C01161842 C01161842 11 /04/2004 11/04/2005 $1,000,000.00 11 /03/2004 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https://fortress.wa.gov/lni/bbip/Print.aspx 07/15/2011 LEGAL DESCRIPTION MP Ott r .'. aio. siaaoasoai. t . vo fe . ao:7 Aallih. : Ott . , 111021 33101; . Al P09±1011 OF c.c., tai: MUM* •#pip►. ; 3 lisctioil. to, loingB82P' 23 *Ms, 13151st 1r.![. , R1mCdRD1 or IMO am���my�.,�,�y1AT k/�i�! SC* -• M •e• ,'eeo • A MCI or 02'20. 1s FOWL K y ; ' po �3/�,4,�,.�tens BEI t5!1 � T I ' '2 •sat *AIVIS6 W. . i:Amnia ▪ . '3 #. t1041t 1Br i, . .Th C& 'NORTH 4, f 4 ON :1 • :fir• MVO? •!1(011 AND IA A LaL WITH THE t>a DANAlitni IKR M ClI NCTION ROB 1 Ca or'O ' :k Pp1111 cI1 3ETI#!S 9�t w 44R ja' :A O• Mail met MO* A • • • • 1101MSENT PAS, ' so Dtnaiditog louvy • a; XD : .61 BUMS' MP A 't ROX TELY 1200- AID 440 or Mt 244 cataa . s n eacrrhnr • u 00 14 . nCa • I 4s' *4 ► nsr lk =MAIM 07 -25311 ' -Hr, E 0 00•31, mat t ` A DISD*XCZ 0 O� TO .'198 'ALOE POINT 0r.HiG2911I Qit • • • TWINCI .9Dt]rY 82'"40 +9V.8 , •ice at t .TEIOI.= NORM Was r1O0 • >Ik � 'lam 642..15.1"Blir# moos NoRril bi•lti ■.�l#' ! 4r 341 r.1E'P•,,• • E: LE $1 To 'TEE. #ifl!: Or It•.D aI LOOTS DOIt>4 tB • Ouse use ��Y Y or C: C. T3 s 1I T1LY. LING 01 ' G'T 81 11 :A ib= '1'1!lt�lC! Svrirpi Oa *3a• WT A 'DT CR 0? 3.92 FT, NIR= ! I,ESS, 70 :IC Purer OF �t • . • . . jt au ut CXTY t�E� • nri>w► i oAr..12ta i, • evairs Or SEPARATE PERMIT REQUIRED FOR: ❑ Mechanical ErEtectrical T numbing t?as Piping City of Tukwila 3..PiNG DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: R visions will require a new plan submittal and may include additional plan review fees, I SITE ' AND BUILDING St4fICS BUILDING CODE: 2009 IBC W/ WA STATE AMENDMENTS ZONING: M -2 BUILDING AREA: 20,625 SF SITE AREA: 10.1 ACRES ASSESSOR PARCEL NUMBER: 0004800003 TENANT SPACE: OVERALL AREA: 5669 SF WAREHOUSE: 4,423 SP OFFICE (NE): 1,246 SF AREA OF WORK: 1,246 S.F. TYPE OF CONSTRUCTION: v -B SPRNCLERED OCCUPANCY: 5, 8 -1 AREA CALCULATION'. 3 SIDES OVER 20' 5 =9000 SF. 61 =9000 REVIEWED FOR CODE COMPLIANCE APPROVED JUL 14 2011 AT City of Tukwila a BUILDING DIVISION BUILDING IS HAS OVER 60' COMMON YARD ON ALL SIDES, THEREFORE BUILDING IS UNLIMITED IN AREA PER SECTION 501 SCOPE 0P WORK TO CONSTRUCT NEW SINGLE STO RY OPOICE t0 INCLUDE NON - SEARING UJ,4LLS, NEW SUSP. CEILING, NEW RESTROOMS, NEW EXTERIOR WINDOWS REPLACING EXISTING. FILE COPY Permit No., Hl O g . Ploy review approval is subject to errors and omissions. of construction documents does not authorize :D ton of any adopted code or ordinance. Receipt of approved Fief , ►y and cans is acknowledged: By Date: 7 (psi,/ City Of Tilkwila BUILDING DIVISION • RECEIVED JUL 07 2011 PERMIT CENTER M(1O92 Z: \CAD \2002 \0225 RREEF\Tukwlla Commerce Park \Building C\TI EAST 02- 15- 11 \SD1.dwg, 2 RTU -1 NEW 3TON ROOF TOP UNIT RREERTukwila Commerce Park\Buildina C \TI EAST 02- 15- 11 \TBOX.DWG 6 "0 UP THRU ROOF HVAC OFFICE PLAN SCALE:1 /46=1' -01 AREAS: GROSS OVERALL = 5,669 S.F OFFICE = 1,246 S.F. /SIZE 110X10 \TYP( °iES 285 F 4 tFm DIFFUSER LEGEND �-`- New rooftop unit Two 16 ga. dips per New roof cure 1 It —BEAM PER PLAN RTU CURB DETAIL NTS NEW ROOF TOP UNIT side.. 4-010 screws per clip 1/ 44i ELEVATION VIEW NORTH NTS SYSTEM DESCRIPTION PROVIDE NEW 3TON GAS /ELECTRIC ROOF TOP UNIT WITH NEW WITH DUCTWORK AND DIFFUSERS FOR NEW OFFICE SPACE. TWO NEW REST ROOM EXHAUST FANS. INSTALL GAS PIPING FROM EXISTING GAS LINE TO NEW ROOF TOP HVAC UNIT. REVIEWED FOR CODE COMPLIANCE APPROVED JUL 14 2011 City of Tukwila BUILDING DIVISION Equipment Schedule (new) Tag Make Model CFM Cooling Heating OA CFM V /Ph SOUND RATTING UNIT EER Net BTU'S AFUE db's WEIGHT RTU -1 CARRIER 48TCD004 1200 11 34,600 72,000 82.O% 200 460/3 80 483 EF -1,2 BROAN QTRN 80 80 115/1 1.5 SONES 12 Supply RTU -1 with economiser Se.en day programmable thermostat w /night setback M�I�Rz RECEIVE: JUL 0 w r PERMIT GENTS