MECHANICAL PERMIT
3523049119
18255 SEGALE PARK DR B TUKW
Project Name: A- AMERICA
Permit Number: M11 -098
Issue Date: 07/20/2011
Permit Expires On: 01/16/2012
Owner:
Name:
Address:
Contact Person:
Name:
Address:
Email:
SEGALE PROPERTIES LLC
PO BOX 88028 , TUK'WILA WA 98138
JOFFRE SECHIER
6802 S 220 ST , KENT WA 98032
JO FFRE@ C OMFO RTMECH. C O M
Contractor:
Name: COMFORT MECHANICAL INC
Address: 6617 S 193 PL, #P -105 , KENT, WA 98032
Contractor License No: COMFOMI015LA
Phone: 206 - 963 -3862
Phone: 425 - 251 -9840
Expiration Date: 06/01/2012
DESCRIPTION OF WORK:
REPLACE (1) EXISTING 5 -TON ROOFTOP HEAT PUMP WITH NEW 5 -TON ROOFTOP HEAT PUMP
WITH ECONOMIZER AND ADAPTOR CURB.
Value of Mechanical: $6,500.00
Type of Fire Protection: UNKNOWN
Electrical Service Provided by:
Permit Center Authorized Signature:
I hereby certify that I have read and
governing this work will be complie
Fees Collected: $269.31
International Mechanical Code Edition: 2009
Date:
ned this permit and know the same to be true and correct. All provisions of law and ordinances
whether specified herein or not.
The granting of this permit does not p
construction or the performance of work.
back of this permit.
Signature:
Print Name:
e to give authority to violate or cancel the provisions of any other state or local laws regulating
I am authorized to sign and obtain this mechanical permit and agree to the conditions on the
This permit shall beco
or abandoned for a pe
m
d of
Date: 71Z0 it 1
W
d void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
days from the last inspection.
doc: IMC -4/10
M11 -098 Printed: 07 -20 -2011
PERMIT CONDITIONS
Permit No. M11-098
1: ** *BUILDING DEPARTMENT CONDITIONS * **
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center
(206/431- 3670).
4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
5: Readily accessible access to roof mounted equipment is required.
6: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary
sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other
excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of
this requirement.
8: Manufacturers installation instructions shall be available on the job site at the time of inspection.
9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila
Building Department (206- 431 - 3670).
10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206- 431 - 3670).
11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
doc: IMC -4/10
M11 -098 Printed: 07 -20 -2011
CITY OF TUKWILA
Community Development Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
htto://www.TukwilaWA.00v
Mechanical Permit No.
Project No.
M41 -t? tS
(For office use only)
MECHANICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *please print"
SITE LOCATION
Site Address: /
Tenant Name: /7
Property Owners Name:
Mailing Address: 1 v
4- Y k. R!/. e
ich.„0. Plc Lltd"
King Co Assessor's Tax No.: 35.30 Lig 119
Suite Number:
Floor:
New Tenant: ❑ Yes ❑ ..No
City State Zip
CONTACT PERSON — who do we contact when your permit is ready to be issued
Name: rr
Mailing Address: lD
tiQ
Day Telephone.
Wo1
E -Mail Address: ‘3ta
l td. fAw%
City LI1� State [�[�� "Zip
Fax Number: 400 S '-' I— 7 $ 1
MECHANICAL CONTRACTOR INFORMATION
Company Name: CCIA-PDA. � tux 1
Mailing Address: kilt s3.
Contact Person:
E -Mail Address:
Contractor Registration Number: C.OVKVOYIZCIIS ('T
City
b4 980)
state Zip
Day Telephone?aCt— ((A03'‘3k1k)
Fax Number: 11 S &1 )a-94-1
Expiration Date: 13121 t3( (c0
[iCIIITECT OF RECORD — All plans must be stamped by architect of record
Company Name:
Mailing Address:
City
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
State
Zip
ENGINEER OF RECORD — All plans must be stamped by engineer of record
Company Name:
Mailing Address: .D1900)
J�r 40111-
Contact Person: K�.+
E -Mail Address: 4 - CCC.Q. � V $ V GYM
a*. °
VS i
1VNW■ LA ! tQC1 k0
City State il C�Zip
Day Telephone: D00-509— 9 / %t O
Fax Number:
H :Wpplications\Fonns- Applications On Line\2010 Applications \7 -2010 - Mechanical Permit Application.doc
Revised: 7 -2010
bh
Page 1 of 2
•
Valuation of project (contractor's bid price): $
C0stc
Sc. •e of work (please provid detailed information
•
Art .4
Use: Residential: New ❑ Replacement
Ea;1(
Commercial: New ❑ Replacement
Fuel Type: Electric ( Gas ❑ Other:
Indicate type of mechanical work being installed and the quantity below:
Unit Type:
Qty
Unit Type:
Qty
Unit Type:
Qty
Bioler /Compressor
Qty
furnace <100k btu
air handling unit
>10,000 cfm
fire damper
0 -3 hp /100,000 btu
furnace >100k btu
evaporator cooler
diffuser
3 -15 hp /500,000 btu
floor furnace
ventilation fan connected
to single duct
thermostat
15 -30 hp /1,000,000
btu
suspended/wall/floor
mounted heater
ventilation system
wood/gas stove
30 -50 hp /1,750,000
btu
appliance vent
hood and duct
emergency
generator
50+ hp /1,750,000 btu
repair or addition to
heat/refrig/cooling system
Incinerator — domestic
othe mechanical
equipp ment
air handling unit <10,000
cfin
l
incinerator — comm/ind
PERMIT APPLICATION NOTES - •
Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the permit center to comply with current fee schedules.
Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing
and justifiable cause demonstrated. Section 105.3.2 international building code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
AUTHORIZED AGENT:
Print Name:
Mailing Address:
Date:3-/L/ I I
Day Telephone:'fe — t4
City
State
Zip
Date Application Accepted: 1_ Rs t I
Date Application Expires: (— I ?`
Staff Initials: lij ' 1
H:\Applications \Farms - Applications On Line \2010 Applications \7 -2010 - Mechanical Permit Applicatioa.doc
Revised: 7 -2010
bh
Page 2 of 2
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.TukwilaWA.gov
RECEIPT
Parcel No.: 3523049119 Permit Number: M11 -098
Address: 18255 SEGALE PARK DR B TUICW Status: PENDING
Suite No: Applied Date: 07/13/2011
Applicant: A- AMERICA Issue Date:
Receipt No.: R11 -01450
Payment Amount: $269.31
Initials: WER Payment Date: 07/13/2011 01:38 PM
User ID: 1655 Balance: $0.00
Payee: JOFFRE SECHIER
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Credit Crd VISA
Authorization No. 513173
ACCOUNT ITEM LIST:
Description
269.31
Account Code Current Pmts
MECHANICAL - NONRES
PLAN CHECK - NONRES
000.322.102.00.00 215.45
000.345.830 53.86
Total: $269.31
doc: Receiot -06 Printed: 07 -13 -2011
.. - .-
I N S P E C T I O N RECORD
Retain a copy with permit
INSPECTION O.
MI( -cYZ
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 lg., (206) 431 -3670
Permit Inspection Request Line (206) 431 -2451
Project: � A A 1 ( �
�t if ,
Type � N � Inspection: A
tL -
Address:
'2S S
Date Called:
Special Instructions: ( ,^
V 5 (S-44 `� - Of X
ij a ,..7 V
Date Wanted:
I ��a.rpr
- L� -1( ( P.m.
Requester:
•
Phone No:
r
C93 —I (P 2f
Approved per applicable codes.
aCorrections required prior to approval.
COMMENTS:
m7F-t0L--iiteA?
InspeQtor:
(IAA J
ON FEE REQUIR
Dat ? /s` I(
REINSPECT( ior`to next inspection, fee must be
paid at 6300 Southcenter Blvd., Ste 100. Call to schedule reinspection.
//
�4
Project: A- America 5T Pkg HP
Prepared By:
Unit Report For 5T Pkg HP -460v
07/08/2011
08:07AM
Unit Parameters
Unit Model. 50TCQA06A2A6 -0A0A0
Unit Size. 06 (5 Tons)
Volts- Phase - Hertz- 460 -3 -60
Heating Type. Heat Pump
Duct Cfg. Vertical Supply / Vertical Return
Standard One -Stage Cooling Refrigeration Coil
Unit Configuration
Medium Static Option Belt Drive
AI /Cu - Al /Cu
Electro- mechanical controls
Standard Packaging
Dimensions (ft. In.) & Weight (1b.)***
Unit Length. 6' 2.375"
Unit Width. 3' 10.75"
Unit Height. 3' 5.375"
Base Unit Weight. 590 lb
"' Weights and Dimensions are approximate. Weight does not include roof
curbs, unit packaging, field installed accessories or factory
installed options. Approximate dimensions are provided primarily for
shipping purposes. For exact dimensions and weights, refer to appropriate
product data catalog.
Economizer Weight = 631bs
Adapter Curb Weight = 1631bs
FILE COPY
Warranty Information �"� ?c^,
5 -Year electric heaters (STD.)
1 -Year parts (STD.) _
5 -Year Compressor (std.p/ _
r
No optional warranties were selected.
NOTE: Please see Warranty Catalog 500 -089 for explanation of policies and ordering met
Ordering Information
REVIED FOR
CODE COMPLIANCE
APPROVED
JUL 2 0 2011
City of BUILDING r
DIVISION
Part Number
Description
Quantity
50TCQA06A2A6 -0A0A0
Rooftop Unit
1
Accessories
CRHEATER108A00
10.6/11.5 kW 460/480 -3 -60 Volt Electric Heater
1
CRECOMZR020A02
Vertical EconoMi$er IV with solid -state controller
1
CDI 3520 -4000 Adapter Curb -1 each
i 0 98
RECEIVE
E
JUL 13 2011
P E R M I T CENTER
Packaged Rooftop Builder 1.29f
Page 1 of 6
Project: A- America 5T Pkg HP
Prepared By:
Certified Drawing for 5T Pkg HP -460v
07/08/2011
08:07AM
NOTES
1 DIMENSIONS ARE IN INCHES DIMENSIONS
IN 1 1 ARE IN MILLIMETERS.
2 S CENTER OF GRAVITY
3 DIRECTION OF AIR FLOW
FILLER ACCESS PANEL
ITOOL-LE551
INDOOR COIL
ACCESS PANEL
F -3/4
1951
COMP.
ACCESS
• PANEL
BACK
UNIT J 6
501C3804 33 3/8 18 5/8
18171 14721
S0TCOA05
33 3/8
(8471
1/ 118
13/71
501COA06
41 3/8
[10511
11 7/8
[377]
50110607
41 3/8 14 1/8
110511 [3771
CONDENSER
COIL
2.5/8 --I
1611
777
CURB
WIDTH
CONDENSER
CO11
OPIIONAL
FACTORY
1X5 FALLED
CONVENIENCE
OUTLET
44
4-518
[1181
Jr
----ELECTRICAL
DISCONNECT
LOCATION
6.5/8
11681
— 46 -3/4
11871
LEFT
19 -1 /2
14941
18-1/8
14591
12 -1 //
13121
SEE THRU THEJ
BASE CHART
0
UNITED 10 pox Me
TECHNOLOGIES 3418[18. 1
CARRIER 14001
11113 0011X041 IS 114 1101[111 OF 11113/1 8/1148/100
3X0 13 11111.1101 ION 111 EIIIESS CONDITION 0631 I1
C0l7E473 111 101 BE D10CIOSEO 08 USED 11X011 CARRIE.
CORPORATION'S 11110' CONSENT
3454133(04 OF 14031 D1111868 01 001441176
DOES 401 CO0S1(11E 11 E 01
ACCEII3NCE Of 1041114181
333/8
18481
ECONOMIZER HOOD
/67110NAL1
16
11061
25 -5/8
16521
RETURN AIR
E ALT. -/
CONDENSATE
DRAIN OPENING
IN BA5EPAN
6.1/4
10 -1 /8
12(11
,j1571
173/1
14511
SUPPLY
AIR
25 —,
16361
32 (/1
18181
TOP
12-1/8
13011
— 181/2 --
14701
OPTIONAL CONTROL BOX
FACTOR) ACCESS PANEL
INSTALLED
DISCONNECT
INDOOR BLOWER
ACCESS
100
HANDLE
74 3/6
818881
FRONT
HANDLE
RETURN
AIR
293/8
[IAN
25-1 /2
[6711
3 -3/8
[851
SUPPLY
AIR
113/8
[2891
1 I
6.1/8
11551
IHRU -111E -BASE CHART
THESE HOLES REQUIRED FOR USE
088 IHPWR001AOI
THREADED
CONDUIT SIZE
WIRE
USE
RE0'D HOLE
SIZES 1146X.1
1/2'
ACC
7 /8' 122.21
1/2'
210
7/8' 122.21
3/4' 10011
POWER
1 1/8' 128.41
FOR 'T080-1/1-BASE AN' FACTORY OPTION.
FITTINGS FOR ONLY 6 l Y ARE
PROVIDED
SELECT EIIHCR 3/4' OR 1l2.
FOR POWER. DEPENDING ON WIRE SIZE
10 -1/2
12651
1.1/4
1311
E STD.—
CONDENSATE
(TRAIN
CONNECTION SI /ES
A
1 3/8' 1351 DIA FIELD POWER SUPPLY HOLE
8
2' 1511 DIA POWER SUPPLY 6NOCAOUT
16 3/4 —
14271
SUPPLY AIR
1 111' 1441 DIA GAUG1 ACCESS PLUG
D
7/8' 1221 DIA FIELD CONTROL WIRING HOLE
E
3/4.11 NPT CONDENSATE DRAIN
0
2 1/2 ' [611 DIA POWER SUPPLY KNOCK -OUT
IHRU -111E -BASE CHART
THESE HOLES REQUIRED FOR USE
088 IHPWR001AOI
THREADED
CONDUIT SIZE
WIRE
USE
RE0'D HOLE
SIZES 1146X.1
1/2'
ACC
7 /8' 122.21
1/2'
210
7/8' 122.21
3/4' 10011
POWER
1 1/8' 128.41
FOR 'T080-1/1-BASE AN' FACTORY OPTION.
FITTINGS FOR ONLY 6 l Y ARE
PROVIDED
SELECT EIIHCR 3/4' OR 1l2.
FOR POWER. DEPENDING ON WIRE SIZE
10 -1/2
12651
1.1/4
1311
E STD.—
CONDENSATE
(TRAIN
'
25.1/B
16381
RETURN
AIR
1
16 3/4 —
14271
SUPPLY AIR
//IILAA�,
FILTER
1 OUTSIDE
AIR
21 -1 /4
15391
-5/8
[168)
26 3/4
16811
AIR
SUPPLY ir 17931
RIGHT
RETURN
RER
BAROMETRIC
RELIEF
FLOW
D10
03 -10-09
01-23-09
50TC0 04-07 SINGLE ZONE ELECTRIC
HEAT PUMP
48114501501
1.
5.0
Packaged Rooftop Builder 1.29f
Page 2 of 6
•
Project: A- America 5T Pkg HP
Prepared By:
Certified Drawing for 5T Pkg HP -460v
07/08/2011
08:07AM
UNIT
STD. UNIT
WEIGHT
CORNER
RE1041 (4]
CORNER
WEIGHT 1B)
CORNER
0E1681 IC]
CORNER
WEIGHT IDI
C G.
HC IGIIT
LBS.
KG.
LBS
KG.
185.
KG.
LBS
KG.
LBS.
KG.
X
Y
1
501(0604
505
229
136
62
130
59
111
53
123
56
36 1/4
19211
21 1/8
15621
16 3/8
14161
501(0905
501C0A06
510
590
231
268
138
159
63
72
131
146
59
66
118
137
54
62
124
149
56
68
36 1/4
35 5/8
19211
19051
21 1/8
22 5/8
15621
15151
16 1/2
20 1/8
14191
75111
501(0901
630
286
166
15
166
75
149
68
149
68
31 1/4
19461
22 1/8
15621
20 3/4
15711
CORNER A
E.
0
841)65 1D. W15505
TECHNOLOGIES fmrufr. 05
(ARRIER 1510/
I01f 00[50[11 If 151 1101(1/1 3) 155515 giT1T,7a f1ENIffIOY W 1NU[ Dnnxcf Of DOCYMrnf
4N0 If S IV(116 YIDY MN1 5[115 f5 COYDI110Y 5) 0055 1 105511(0 155i IEfi01YAYC[ Ot
1011[55 0111 151 11 D IOCI Of[0 W Yf(D 011NOY1 (140151 ,1((51155[[ 00 [01115[1
1oDln14na's 55/1¢5 GOYIM
CORNER B
CORNER C
[ l 00
FRONT
50151
2 OF 2
5511
surrrcurs
03-10-09 1 01 -23 -09
50TCO 04-07 SINGLE ZONE ELECTRIC
HEAT PUMP
480M501501
Iry
5.0
Packaged Rooftop Builder 1.29f
Page 3 of 6
1 15 3/4"
- °r
22 1/8"
25 1/8"
INSULATED
COVER
33 15/16"
70 7/8" 1
Notes:
1. 1.5" ADDED TO OLD CURB O.D
2. MATERIAL 18 ge. GALVANIZED STEEL
3. GASKET PROVIDED WITH CURB
4. INSULATION: 1" 1 1/2 LB DENSITY
89 5/8"
p IEN3gNED AND TOLERENCED PER ANSI 314.61.1112
Attn: Tag:
Approval:
EXISTING CURB LAYOUT
57 12"
47 1/4"
SMALL
2 114'
SUPPLY
2 1/4"
RETURN
20 3/8" 1
24 5/8"
45"
88 1/8"
2 1/4"
REVISIONS
REV.
DESCRIPTION
INITIAL DWG
DATE I APPROVED
6/23/2006
46 3/4"
LARGE
20 3/8"
SUPPLY
24 5/8"
RETURN
44 12"
33"
2 1/4"
BOTH LARGE AND SMALL EXISTING LAYOUT ARE SHOWN
3D DRAWING DEPICTS LARGE CONFIGURATION
CURB SHOWN IS CDI STANDARD CONFIGURATION
CDI RESERVES THE RIGHT TO CHANGE LAYOUT
WITHOUT NOTIFICATION. IF CURB IS NEEDED IN A
DIFFERENT CONFIGURATION CDI MUST BE NOTIFIED
PRIOR TO PLACING AN ORDER.
CURB WEDM(LBSJ
APPROVALS
DATE
162.65
°'"` gletcher
"VERHT 6.313 ONG Luke 00
'VERIFY SUPPLY AND RETURN OPENINGS
'NOTE ANY CHANGES
'CALL WITH ANY QUESTIONS
FAX BACK IF DRAWING IS OK AS IS
�
Thursday, January 13, 2011
CDI
6:33:52 PM
'1"` 1- 3520-4000 Large
QUOTE #:
17560 TYLER ST NW
ELK RIVER, MN 65330
(763)331 -7700
631391 -7851
lila 1,1461112
1- 3520-4000Large
1:25 I NREr. 1 as 3
Project: A- America 5T Pkg HP
Prepared By:
Performance Summary For 5T Pkg HP -460v
07/08/2011
08:07AM
Part Num ber:50TCQA06A2A6-0A0A0
ARI SEER: 13.20
Base Unit Weight 590 lb
Base Unit Dimensions
Unit Length. 74.4 in
Unit Width* 46.8 in
Unit Height 41.4 in
Unit Voltage- Phase - Hertz. 460 -3 -60
Air Discharge. Vertical
Fan Drive Type. Belt
Actual Airflow* 2000 CFM
Site Altitude. 0 ft
Cooling Performance
Condenser Entering Air DB. 95.0 F
Evaporator Entering Air DB' 80.0 F
Evaporator Entering Air WB. 67.0 F
Entering Air Enthalpy 31.44 BTU /Ib
Evaporator Leaving Air DB• 58.1 F
Evaporator Leaving Air WB. 57.4 F
Evaporator Leaving Air Enthalpy 24.63 BTU /Ib
Gross Cooling Capacity. 61.30 MBH
Gross Sensible Capacity* 47.30 MBH
Compressor Power Input 5.50 kW
Coil Bypass Factor 0.203
Heating Performance
Outdoor Ambient Temperature* 47.0 F
Entering Air Indoor Coil DB* 70.0 F
Leaving Air Indoor Coil DB. 97.0 F
Total Heating Capacity: 58.40 MBH
Integrated Heating Capacity. 58.40 MBH
Heating Power Input 4.65 kW
HSPF. 7.7
Electric Heating Capacity. 10.60 kW
Unit Leaving Air Temp. 113.8 F
Supply Fan
External Static Pressure' 0.60 in wg
Options / Accessories Static Pressure
Electric Heaters' 0.11 in wg
EconoMi$erIV / EconoMi$er2. 0.12 in wg
Total External Static: 0.82 in wg
Fan RPM* 1238
Fan Power 1.36 BHP
Electrical Data
Minimum Voltage* 414
Maximum Voltage. 506
Compressor #1 RLA. 7.7
Compressor #1 LRA* 52
Actual Electric Heater kW:....... 10.6
Electric Heater FLA. 13.8
Outdoor Fan Motor Qty. 1
Outdoor Fan FLA (ea)* 0.8
Indoor Fan Motor Type. MED
Indoor Fan Motor FLA. 2.6
Packaged Rooftop Builder 1.29f Page 4 of 6
Project: A- America 5T Pkg HP
Prepared By:
Performance Summary For 5T Pkg HP -460v
07/08/2011
08:07AM
Power Supply MCA: 30.3
Power Supply MOCP (Fuse or HACR):__ ___ __ ____ . _ _. 35
Min. Unit Disconnect FLA. 29
Min. Unit Disconnect LRA. 83
Electrical Convenience Outlet: None
Acoustics
Sound Rating. 80.0 db
Sound Power Levels, db re 10E -12 Watts
Discharge Inlet Outdoor
63 Hz 89.2 88.6 92.7
125 Hz 82.8 79.4 84.9
250 Hz 75.2 67.2 79.0
500 Hz 72.6 65.2 76.7
1000 Hz 71.8 66.9 73.8
2000 Hz 66.8 61.6 69.6
4000 Hz 68.5 57.6 66.4
8000 Hz 65.2 50.7 62.8
A- Weighted 77.2 71.4 79.5
20
18
16
FanCurve
- "i1 M
. HP
RPN
- 70CRPM
04
02
03 C6 09 12 15 18 21
arfow(CFM -t ousands)
RPM =1238 BHP =1.36 MaximumRPM =O MaximumHP =2.90
Note: Please contact applicationengineering for selections outsidethe shadedregion.
SC- System Carve RP -RatedPoint
24
27
Packaged Rooftop Builder 1.29f Page 5 of 6
Project: A- America 5T Pkg HP
Prepared By:
Unit Feature Sheet for 5T Pkg HP -460v
07/08/2011
08:07AM
WeatherMaker'- 50TCQ
PACKAGED ROOFTOP HEAT PUMP UNITS
3, 4, 5, 6.7 -1 /2r 8- 112,10 and 12.5 TONS
50TCO units are high - efficiency single- packaged heat pump units
that are pre -wired and pre - charged with PURON (HFC)
refrigerant. Electric heat is available as a field- installed accessory.
The units are fully factory tested and agency certified.
Certified to ISO 9001:2008
A81 S4odard
210/210 UHP
Sizes 04 -06
3401380
Sizes 07 -14
PERFORMANCE FEATURES
• PURON (R -410A) HFC refrigerant
• ASHRAE compliant and Energy Star qualified
• SEERs up to 13.4, EERs up to 11.2
• IEER's up to 12.2
• HSPFs up to 7.7 and COP's up to 3.3
• Single stage cooling capacity control an 04 —07 models
• Tim-stage coaling capacity control on 08 - 14 models
• Exclusive non-corrosive composite condensate pan in accordance With
ASHRAE 82 Standard, sloping clesgrc side or center drain
• Convertible from vertical to horizontal airflow for slab mounting
• Copper tube aluminum In coils With optional corrosion resistant coils
• Pre - painted exterior panels and primer coated interior panels tested to
500 hours salt spray protection
• Acutral" refrigerant metering system
• Cooling operating range up to 115E (48C) and down to 25F ( -4C)
• Solid-state control board and easy access terminal board
• Refrigerant filter drier and accumulator
• Fully insulated cabinet
• Automatic changeover when used with auto - changeover thermostat
• Rated in accordance with ARI Standards 240 (04-08 sores) and
340 (07 -14)
• Designed in accordance with Underwriters' Laboratories Standard 1995
• Listed by UL and UL, Canada
MAINTENANCE FEATURES:
• Access panels with easy grip handles
• Innovative. easy staring. no strip screw features on unit access panels.
• Two-inch disposable return air filters
• Tool -less filter access door
• Belt drive evaporator -fan mean and pulley combinations available on all
sizes to meet any application
• Electric Drive x13 (5 speeditorque) motor on 09 to 08 models
• New terminal board facilitalirgl sirnpie safety circuit troubleshooting and
simplified control box arrangement
INSTALLATION FEATURES:
• Thru-rhe- bottom power entry capabllity standard
• Single point electric cannections
• Full perimeter base rail with built -in rigging adapters and fork truck slots
RELIABILITY FEATURES:
• Scroll compressors with internal frnebreak overload protection
• Dependable Time / Temperature defrost board and logic
• 24-volt control circuit protected with resettable circuit breaker
• Permanently lubricated evaporator -fan motor
• Totally enclosed condenser motors w:th permanently lubricated
bearings
• Lass of charge. freeze protection, and high - pressure switches
STANDARD WARRANTY:
• 5-year electric heaters
• 5-year compressor
• 1-year parts
Many optional warranties also available
OPTIONS INCLUDE BUT ARE NOT LIMITED TO:
• Multi Protocol (RTU -MP) and PrennierLink^r Direct Digttal Controllers
• 115 -voit convenience cutlet (Powered and Unpawered)
• Non-fused disconnect snitch
• Economizer options far eiectro-mechanical and DDC control
• Corrosion resistant coil options far evaporator and condenses
• Optional indoor fan cocas for expanded airflow capability
• Accessory electric heat (field-installed option only)
• Snake detectors — Supply and Return arc
Packaged Rooftop Builder 1.29f Page 6 of 6
rite rnfrty
STRUCTURAL CALCULATIONS AND DETAILS FOR
A AMERICA - RTU
18255 SEGALE PARK DR B
TUKWILA, WASHINGTON
PREPARED FOR:
COMFORT MECHANICAL
JULY 9, 2011
REVIEWED F
CODE COMPLIANCE
APPROVED
JUL 2 0 2011
City of Tukwila
BUILDING DIVISION
CASCADE CREST CONSULTING ENGINEERS. INC.
21902 96TH AVENUE SE
SNOHOMISH, WASHINGTON 98296
(206) 909 -7808
PREPARED BY: KEITH MOORE, S.E.
EXPIRES 6 1I2I i3
ECEOVE
JUL 13 2011
PERMIT CENTER
U;A? v' i.J e'
ro o 'h, rya v'e ram t
4- 1.11...L
roo -C-t °° -rn ��e.r c
PV-
0 . 6 L 4 3 - Climc
CASCATIR CREST CONSULTING 6Na®oRCEINS. btc
(9
PROJECT:
1
-P-TO
o� 4; j't'j
ENGR: /661-141,
DATE: 7'4 it t
SCALE:
SHEET
- At'cA
18 2S8 S 0: A L e i?"fs
Tvkwt LA, Wj (Mgt
g
jxr 11 1t4 t; VlirT S-ir P. • New rT%c %itl
Lom z I 1 �0 c �� %we, = 1 Z5" peg6
tT :- o-tAL. ` 1 `
A
r 251
1 2S1
1 25'
25' 1
AMAX A
BEA Nt
63 /1x t4x
is -.:5tA cA
r 4xi9�.,t'o.c.,
%R t..' N
,itizuc .
, Ai
cl us
•2x4 9c :Z I g4.4 , .
Sva R .
VA:— 1'
I4c6, + (Izy -4 ico3 + (a)/4 - z3474
C ti -
o i cP
.tom — (/ '15 rr
21?$ 20'6
``1 1,r�.
S {� :216( +Q 244
Ski Ill
77Z— 117 ÷ 11-7 –I- 616--I 14,1+&3
VI ' 41-49 6*'/N4 — 1
R , — s�$ (cvao) %.5 efi G - 2 S r
7.01-1(0
•
Icoco
/ • . . v ,e0 3 Vi.o its-
--.'
. l a L 34103 / ►'Lo ; r AA- - C i c ,-oAr
CASCADE CREST COKSULtoaa Fiume. arc.
PROJECT:
A._ Ay- A-11.-r
12-TL)
ENGR: / L(
DATE: -I/ q. l Illl
SCALE:
SHEET
cttf/Lkc
LJ If-CD
a : o„ O3 2 ?(0 14 v
0.0 `3256 0.851(")(o.7,(c-1'6,)) !(,jSF
/6.1 75 • /q, 3 1.1-S° 1 -- f q
r0.4
Ile 14
6,4 (1,610 .VSI)(q40
.
4
( �� l0, 7.)3 C 2Atua,c_.
CASCADR CREST consomme EInesamss. orc.
PROJECT:
ENGR: 6 4(
DATE: -y l a if
SCALE:
4/,
SHEET
J,�
9
t4ers it II
E R
Cfi�P�
Fool pp oF
-E,Lz 1-4-W c-
F7mar 12-A.1,4 Li cq 191)-ki
CASCADE CREST CONSULTDIG ENGINEERS. INC.
PROJECT:
Aswi
ZTU
ENGR: I6∎ ;a6
DATE: 719, %t
SCALE:
9"/I
SHEET
GENERAL STRUCTURAL NOTES:
1. ALL MATERIALS, WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO
THE DRAWINGS AND THE INTERNATIONAL BUILDING CODE (IBC), 2009 EDITION.
2. DESIGN LOADING CRITERIA:
ROOF LIVE LOAD
MECHANICAL UNITS
EARTHQUAKE
WIND
25 PSF
941 POUNDS
Srs = 0.881
SITE CLASS D TO E
85 MPH, EXPOSURE C
3. STRUCTURAL CALCULATIONS AND DETAILS SHALL BE USED IN CONJUNCTION WITH
MECHANICAL DRAWINGS FOR BIDDING AND CONSTRUCTION. CONTRACTOR SHALL
VERIFY DIMENSIONS AND CONDITIONS FOR COMPATIBILITY AND SHALL NOTIFY
ENGINEER OF ALL DISCREPANCIES PRIOR TO CONSTRUCTION.
4. CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS, MEMBER SIZES AND
CONDITIONS PRIOR TO COMMENCING ANY WORK. ALL DIMENSIONS OF EXISTING
CONSTRUCTION SHOWN ARE INTENDED AS GUIDELINES ONLY AND MUST BE
VERIFIED. THE EXISTING CONDITIONS SHOWN ARE BASED EITHER ON SITE
OBSERVATION, ORIGINAL DRAWINGS, OR WERE ASSUMED BASED ON EXPECTED
CONDITIONS. IF THE EXISTING CONDITIONS DO NOT CLOSELY MATCH THE
CONDITIONS, OR IF THE EXISTING MATERIALS ARE OF QUESTIONABLE OR
SUBSTANDARD QUALITY, NOTIFY THE ENGINEER PRIOR TO COMMENCING ANY
WORK.
5. CONTRACTOR SHALL PROVIDE TEMPORARY BRACING FOR THE STRUCTURE AND
STRUCTURAL COMPONENTS UNTIL ALL FINAL CONNECTIONS HAVE BEEN
COMPLETED.
6. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND THE
METHODS, TECHNIQUES, SEQUENCES, OR PROCEDURES REQUIRED FOR THE
COMPLETION OF THE WORK.
7. CONNECT THE NEW UNIT TO THE METAL CURB ADAPTER AND THE METAL CURB
ADAPTER TO THE EXISTING METAL CURB WITH #10 SHEET METAL SCREWS AT 24" ON-
CENTER. IF DIFFERENT SCREW SIZE IS UTILIZED, VERIFY SPACING WITH
STRUCTURAL ENGINEER.
8. SHEET METAL SCREWS SHALL CONFORM TO THE AMERICAN IRON AND STEEL
INSTITUTE (AISI) "SPECIFICATIONS FOR THE DESIGN OF COLD -FORMED STEEL
STRUCTURAL MEMBERS ".
9. AT CONTRATOR'S DISCRETION, THE CONNECTION OF THE MECHANICAL UNIT TO
CURB MAY BE PERFORMED UTILIZING 18 GAGE GALVANIZED METAL STRAPS.
NOTIFY STRUCTURAL ENGINEER IF THIS CONNECTION OPTION IS UTILIZED.
10. METAL STRAPS, IF UTILIZED, FOR ANCHORAGE OF MECHANICAL UNITS SHALL
CONFORM TO ASTM A446 GRADE A WITH A MINIMUM YIELD STRESS OF 33 KIPS PER
SQUARE INCH.
'PA
11. PROVIDE A 2x6 SUBPURLIN AT THE EDGE OF EXISTING THE METAL CURB WITH LUS26
HANGERS OR "SISTER" A 2x6 TO THE EXISTING 2x4 SUBPURLIN AT THE EDGE OF THE
EXISTING METAL CURB WITH 10d NAILS AT 8" ON- CENTER, STAGGERED.
12. FRAMING LUMBER SHALL BE KILN DRIED OR MC -19, AND GRADED AND MARKED IN
CONFORMANCE WITH W.C.L.B. STANDARD GRADING RULES FOR WEST COAST
LUMBER NO. 17. FURNISH TO THE FOLLOWING MINIMUM STANDARDS:
JOISTS: (2x MEMBERS)
HEM -FIR NO.2 Fb = 850 PSI, Fv =150 PSI
13. TIMBER CONNECTORS CALLED OUT BY LETTERS AND NUMBERS SHALL BE "STRONG -
TIE" BY SIMPSON COMPANY, AS SPECIFIED IN THEIR CATALOG NO. C -2011.
771l
Project A- America 5T Pkg HP
Prepared By..
Unit Report For ST Pkg HP -460v
07/0812011
08:07AM
Unit Parameters
Unit Model: 50TCQA06A2A6-0A0A0
Unit Size: 06 (5 Tons)
Volts- Phase-Hertz:_ 460440
Heating Type: Heat Pump
Duct Cfg• Vertical Supply / Vertical Retum
Standard One-Stage Cooling Refrigeration Coll
Unit Configuration
Medium Static Option Belt Drive
Al/Cu -Al/Cu
Electro4rnechanicol controls
Standard Packaging
Warranty Information
5-Year electric heaters (STD.)
1-Year parts (STD.)
5-Year Compressor (std.)
No optional warranties were selected.
Dimensions (ft. In.) & Weight (Ib.) "'
Unit Length: 6' 2.375"
Unit Width- 3' 10.75"
Unit Height 3' 5.376"
Base Unit Weight_ b80 lb
*" Weights and Dimension are appaodmate. Wight dons not include roof
curbs, unit packaging. field installed olfactory
Installed onions. Appradnmte dimensions are provided prlmer*y for
shipping purposes. For exact dimension and weIgMs. refer to appropriate
product data catalog.
Economizer Weight = 631bs
Adapter Curb Weight = 1631bs
NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods.
Ordering Information
Part Number
Description
Quantity
50TCQA08A2A8-0A0A0
Rooftop Unit
1
Accessories
CRHEATER108A00
10.6111.5 kW 480/480 -3-60 Volt Electric Heater
1
CRECOMZR020A02
Vertical EconoMi$er IV with solid -state controller
1
CDI 3520 -4000 Adapter Curb -1 each
git(
Packaged Rooftop Builder 1.29f Page 1 of 13
Project A- America 6T Pkg HP
Prepared By:
Certified Drawing for 6T Pkg HP -460v
07/0812011
08:07AM
11071.1: y�
0. V1191114% L'I1tl16ft41DlIR111D10
S. Of OIA1I7Y
2. aipp. 011ECT105 Of All 0(00
II11D 0.0. RI uR
100117 MOM, R Mu
BACK
tl7TSs
1 1 � 112
11.1/1
t{ jI SUPPLY
1 Alt
101111
llcnrc*l
111W010C1
LEFT
IMil 1 005
11u1rA I� it litgi t i&i" d+'tn i irlii$`nss-'f"•• w
5p� EL
Ol�ll [0151
LLTIIII.CCISSPIEL.
,
0
11Fu
BACK
tl7TSs
1 1 � 112
11.1/1
t{ jI SUPPLY
1 Alt
101111
llcnrc*l
111W010C1
LEFT
IMil 1 005
11u1rA I� it litgi t i&i" d+'tn i irlii$`nss-'f"•• w
TOQ0•f4.BAIC (cMA3
f0101 MOL[0 t(OR1f* 502 021
C160MC180c1101
C0101C1100 01711
A
1 110. 11151 DIA 01110 PORI 101M1 MOLL
D
1. 1011 OIA KIM OUP0(1 *10((001
C
1 'lll• II /S DIA 01001 MUSS 0100
D
118. 1521 01A 0114.0 CONTROL 0101110 004.1
5
211••11 101 C000EMG15 02110
0
5 1/5 • 1111 DIA PORK SUPPLY 100(2.001
TOQ0•f4.BAIC (cMA3
f0101 MOL[0 t(OR1f* 502 021
C160MC180c1101
(0l Slit
00*4
USE
1
11itf 1 4
11.1
0
Ili'
ACC,
116' 111.1!
3
)10
11*
(16' Itt.t1
0 ,
Ill' 10411
POREI
1 l0* 110.11
10I •1010.7I0:•8AArpa0I• PAC1011,
01111108 100 014.1 t
01001010
001102.
1 3 AU
[ On
00* pORA, DEPtiBlIe d[ Slit
All 110114
IOW
V RIGHT
1110
SUM
ROI
att I "'3- 1 SOTCO 04-07 SINGLE ZONE ELECTRIC I 4 &161501501 15.0
03-10-09 01 23 09 I HEAT PUMP
Packaged Rooftop Builder 1.29f
Page 2 of 6
18814 E
INSULATED
3315116•
TO 718"
1
1. 1.9' ADDED TO OLD CURB 0.0
2. MATERIAL 18 go. GALVANIZED STEEL
3 GASKET PROVIDED YYRH CURB
4. INSULATION: Y1 112 LS DENSITY
•
89 518"
01311111111271117A10 TOUXIIIIXDP•lA11111111U11111
Attn; Tag:
Approval:
EXISTING CURB LAYOUT
r_571/2*
888118'
2 114"
0811AL DWG
LARGE
SUPPLY
RETURN
44 12"
--� � 2114"
33"
BOTH LARGE AND SMALL EXISTING LAYOUT ARE SHOWN
3D DRAWING DEPICTS LARGE CONFIGURATION
CURB SHOWN 18 CDI STANDARD CONFIGURATION
CDI RESERVES THE RIGHT TO CHANGE LAYOUT
WITHOUT NOTIFICATION. IF CURB 18 NEEDED IN A
DIFFERENT CONFIGURATION CDI MUST BE NOTIFIED
PRIOR TO PLACING AN ORDER.
{.-- 409/18"
48114" -.-I
WU MOW pay erreoreu
162.65 ceenee
'Ynorre wacwREfl
ra auu ��0
wn
Mom* lemma 13, 2011 !2322 PM
1-3520-4000 Large
QUOTE#: •
CDI�, �Na
el1cRNER.wuioo3
o T
• 1
Riv
• GENERAL ELECTRIC PRODUCT DATA
• CENTRAL AIR CONDmOMNG DEPARTMENT. TROUP HIGHWAY. TYLER. TEXAS 75711
PRODUCT SPECIFICATIONS
y
MODEL • .
-
- ... ,
��
Bw 4.$ .: !. R/�/ 1.: /
-
V C060C` 00 0.D
�
RATED VOLTS/Pa/HZ.
,. I
I /1g
. 1 1 . . ism
480/9/60
RATING COOLING (1)
8/721 -Le•��
Airflow b►door lur M)
Sods No. EER./&EER.)
..:.,,
2.:
8.38
f o
-/7.65
69 •1 (7)
. 1 1 ,
8.38 • 7.1/7.65
1
.500
69/0
2.000
8.38 7.1/7.65
20
- RAATING HEATING (1)
(►Ugh T e m p ) B I U H
:1!
-1■11
: - :11 1
60:000
System Pawer•Q(W & C.O.P.)
8.88
2.55
8.88 2.56
8.88 - 2.55
(Low Temp.) BTUH
-,,,,,i1
, ^ 111
35.000
System Power 0(W & C.O.PJ
H..S..P.P
5.40
1.90
•
6.40 1.90
5.40 1.90
(BT� U //w t141r.) (8)
:;c
,
1
(1.20
POWER CONNECTIONS
X -.
•
.01 ,..;o1 .
• 460V.
-
Mtn. & Cir. Ampadty (Amps) (3)
`.
17
Fuse Size - Max. - Recm'd. (Amps.) .
80
80
' 50 60
25 - 25
COMPRESSOR - •
- GE 0. ?...:.
,
'GE .: „ .,
GE Clhnatl&M
Vada/Ph./Hz.
230
: /60
le . ! q3/00
480/3/60
RL Amps
.4 .
10.5 •
Brandt dr. Select. Cur. Amps
:
'
-4
10.5
L.R. Amps.
!'
1
63
OUTDOOR COS. - TYPE
• ,:
Fin
: Fh1
Plate Fin
Rows /FP1
4 ;;:13
4 ; 13
4 / 13
Face Area - (S8.. FL)
:.i.
8.33
Tube -- eke en.)
1 '.,
2
1/2
Refrtgerar1t Control . .
=:
Valve
•• • Valve
Expansion Valve
INDOOR COIL - TYPE
Fin
- Fin
Plate Fin
Rows/F.P.I.
3
_:
13
3 ': 13
3 / 13
Face Area - (S0. Ft.)
• 5
-
•
6.38
Tube - size On.)
1
'
2
1/2
Refrigerant - Control '
=,.., .:::
n Valve
- ...:... °. Valve
Exparlon Valve -
0rals Conn. Size (In.)
3/ .
•
3/ = NPT
8/4 NPT
Duct Conn -- Supp y On.)
•
1 81 /2
20-1/2
184/ = . 204/2
18.1/2 x 204 /2
•
Duct. Corns. - Return (Int
246/8
304/4 .
246/ + 30-1 /4
248/0 x 30-1/4
OUTDOOR FAN -- TYPE
Dia. On.)
' • ;:
.:,
• ' :.i
Propeller
18
No. Used
2
Drive/Speed (No.)
1 : >
Mr . ° Single
Diced /Stress
CFM (4)
1
.11
4200
Motor HP. - Speed (RPM)
1/5 31/
` -1625
1/5 31. `,= -1625
1/6 51/4 -1825
Volts/Ph/Hz.
X30
/60
11 `'/1/60
460/1/60
F.L Amps
1.9
2.3 .
1.3' 2.3
0.6 8. 1.0
-
INDO0t FAN -TYPE
►:, ::
..:
Cenheogal
Dia./WIdth (Hr.)
12.8';
9.5
11 : • 9.5
118 x 9.5
N0.• Used
1
•
lklve /speedo (Nos
1 i :-
/ 2
0: . / 3
'SEE FAN • -1.-..
Direct / 3
CFM %e. ta'w8. (5)
1/2 '
825
. •- l
t , 075
1 -1075
Motor H.P. =Speed (RPM)
•Vons/Ph./Hz.
230 '-
/60
es P. /1 J60
480/1/80
FL Amps _
.
2.5
'FILTER (Not Furnished)
Type Recommended
1 ° Thr'...:1
:,
1" ,', , , .: y
1" Throwaway
No./Size (f.)Redsmmeeded
2 -
` x26
' 2 - i s x25
2-18x25
REFRIGERANT ' •
Charge (Ibs. of R- 22).(6)
14 it +
r o¢.
. �•
; 2 p2. -
14 l& 2 oz. •
.
Crated DIMENSIONS
3
I
I 58
0 114
37 I I 66
37
I 48 I 58
Uncrated - Debdi OnJ
SEE • DRAWINGS
WEIGHT ,
.
•
-
Stipp ng Ob .) .
577 •
Net Obn) ..
...
.._ .
685 -
(1) Rated in accedence with A.RL Standard 240.
GI) Rated In accordance with A.RJ. Standard 270.
SINGLE PACKAGE
N Electric Code. watt currently 0
(4) Did. Air - Dry Coll Outdoor
(5) Std. Atr Wet Coll Indoor
(8) This value is approximate. For more precise value..
see unit rite and service Instnicdons. '
(7) Reduce ear by 1,000 BTUH for 200 Voce application.
(8) Rated in accordance with O.O.E. test procedure. H.s.PF.
Is at the minimum design requirement for Region N.
6
- DMA SUBJECT TO CHANCE -WITHOUT NOTICE
•
• •
PLAN REVIEW/ROUTING SLIP
ACTIVITY NUMBER: M11 -098 DATE: 07 -13 -11
PROJECT NAME: A- AMERICA
SITE ADDRESS: 18255 SEGALE PARK DR B
X Original Plan Submittal
Response to Correction Letter #
Response to Incomplete Letter #
Revision # After Permit Issued
DEPARTMENTS:
�-- .l(, 0114 • ��
'naming Division
Public Works
'Fire Preveh 'lion -41
Structural n
Planning Division
Permit Coordinator
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete Incomplete n
DUE DATE: 07 -14 -11
Not Applicable
Comments:
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES /THURS ROUTING:
Please Route 111 Structural Review Required n No further Review Required ❑
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS:
DUE DATE: 08 -11 -11
Approved n Approved with Conditions Not Approved (attach comments) ❑
Notation:
REVIEWER'S INITIALS: DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents /routing slip.doc
2 -28 -02
Contractors or Tradespeople Pter Friendly Page
General /Specialty Contractor
A business registered as a construction contractor with Lal to perform construction work within the scope of
its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Business and Licensing Information
Name COMFORT MECHANICAL
INC
UBI No. 601954041
Phone 4252519840 Status Active
Address 6802 So. 220Th Street License No. COMFOMI015LA
Suite /Apt. License Type Construction Contractor
City Kent Effective Date 6/1/1999
State WA Expiration 6/1/2012
Date
Zip 98032 Suspend Date
County King Specialty 1 Heating /Vent /Air - Conditioning And Refrig
(Hvac /R)
Business Type Corporation Specialty 2 Unused
Parent
Company
es
License
Name
Type
Specialty 1
Specialty 2
Effective
Date
Expiration
Date
Status
FIVESM'01OJT
FIVE STAR
MECHANICAL
Construction
Contractor
General
Unused
4/30/19994/30/2012
Active
COMFOP•064D2
COMFORT
PLUS
Construction
Contractor
Air
Conditioning
Air
Heat,Ventilation,Evaporat
3/22/1994
3/21/2000
Archived
FIVESSE941KU
FIVE STAR
ENERGY
SOLUTIONS
Construction
Contractor
General
Unused
5/24/20065/24/2008
06/01/2005
Expired
Business Owner Information
Name
Role
Effective Date
Expiration Date
JACKSON, SHIRLEY A
President
01/01/1980
Amount
JACKSON, HERB J
Vice President
01/01/1980
9849307
Bond Information
Page 1 of 1
Bond
Bond Company Name
Bond Account Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Bond Amount
Received Date
2
COLONIAL AM CAS Et
SURETY OF MD
LPM4041162
06/01/2002
Until Cancelled
$6,000.00
05/15/2002
Assignment of Savings Information No records found for the previous 6 year period
Insurance Information
Insurance
Company Name
Policy Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Amount
Received Date
8
Federated
Mutual Ins Co
9849307
06/01/2010
06/01/2012
$1,000,000.00
05/03/2011
7
FEDERATED
MUTUAL INS CO
9849306
06/01/2006
06/01/2010
51,000,000.00
05/01/2009
6
FEDERATED
SERV /MUT INS
CO
9849306
06/01/2005
06/01/2006
$1,000,000.00
04 /25/2005
Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period
Warrant Information No unsatisfied warrants on file within prior 6 year period
http s : // fortress. wa. go v/l ni/bb ip /Pri nt. aspx
07/20/2011
PARCEL DATA
Parcel
Name
Site Address
Geo Area
•
352304 -5119 j Jurisdiction TUKWILA
•SEGALE PROPERTIES LLC F s Levy Code i 2360
iii
18125 ANDOVER PARK W i ; i Property Type C
t.,
70 -50 '5 Plat Block / Building Number
Spec Area
500 -25
Property Name
SEGALE BUSINESS PARK
Plat Lot / Unit Number
Quarter - Section- Township -Range
NE -35 -23-4
Legal Description
PAR A OF TUKWILA BLA #L02 -029 REC #20021007900001 SD PAR LOCATED) E 1/2 & SW 1/4 OF SD SEC
ASSESSOR DATA
SITE PLAN
Map of:
18255 Segale Park Drive B
Tukwila, WA 98188 -4733
VICINITY MAP t
SEPARATE PERMIT
REQUIRED FOR
0M
CI Erect
01 Plumbing
4Gas Piping
City of Tukwila
BUILDING DIVISION
2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential
Mechanical Summary
MECH -SUM
2009 Washington State Ener v Code Compliance Forms for Nonresidential and Multifamily Residential
Revised February 2011
Project Info
Brand
Project Address A- AMERICA
Date 7/8/2011
CFM
18255 SEGALE PARK.i +R. B
For Building Dept. Use
TUKWILA, WA 98188
SEER
Applicant Name: JOFFRE SECHIER .
Applicant Address: 8802 S. 220TH ST., KEN-T, WA 8=98032
Applicant Phone: 426- 251 -9840
Project Description
Briefly describe mechanical
system type and features.
❑ Includes Plans
REPLACE (1) EXISTING 5 -TON. PACKAGED HEAT PUMP WITH NEW 5-
TON PACKAGED HEAT PUMP WITH ECONOMIZER AND ADAPTER CURB.
Include documentation requiring compliance with commissioning requirements, Section 1416.
Compliance Option
Q Simple System 0 Complex System 0 Systems Analysis
(See Decision Flowchart (over) for qualifications. Use separate MECH -SUM for simple & complex
Equipment Schedules
The following information is required to be iraorporated with the mechanical equipment schedules on
the plans. For projects without plans, fill in the required information below.
Cooling Equipment Schedule
Equip.
ID
Equip
Type
Brand Name'
Model No.1
Capacity
Btu /h
OSA CFM
or Econo7
SEER
or EER
IPLV3
Econmizer
Option or
Exception°
Heat
Recovery
Y/N
HP -1
HP
CARRIER
50TCQA06
61300
ECONO '
13, 2
N
Heatin • E • ui • ment Schedule
Equip.
ID
Equip
Type
Brand Name'
Model No.1
Capacity
Btu /h
OSA cfm
or Econo7
Input Btuh
Output Btuh
Efficiency4
Heat
Recovery
Y/N
HP -1
HP
CARRIER
50TCQA06
58400
ECONCI
Fan Equipment Schedule
Equip.
ID
Equip
Type
Brand Name'
Model No.1
CFM
Sp'
HP /BHP
Flow Control5
Location of Service
1If available. 2 As tested according to Table 14 -1A through 14 -1G. 3 If required. 4 COP HSPF, Combustion Efficiency, or AFUE, as applicable.
5 Flow control types: variable air volume(VAV), constant volume (CV), or variable speed (VS). 6 Exception number from Section 1433.
PROJECT DESCRIPTION:
1. REMOVE (1) EXISTING 5 -TON ROOFTOP PACKAGED
HEAT PUMP.
2. INSTALL (1) 5 -TON PACKAGED ROOFTOP HEAT PUMP
WITH ECONOMIZER AND ADAPTER CURB.
3. REUSE EXISTING AIR DISTRIBUTION "NO WORK ".
4. REUSE EXISTING THERMOSTAT.
GENERAL NOTES:
1. ECONOMIZER TO PROVIDE 100% OUTSIDE AIR WITH
PARTIAL COOLING.
2. THERMOSTAT TO PROVIDE MINIMUM 5 DEADBAND.
3. INSTALL GFCI OUTLET WITHIN 25' OF UNIT.
4. INSTALL RETURN AIR DUCT SMOKE DETECTOR FOR
UNITS WITH GREATER THAN 2,000 CFM.
5. ROUTE CONDENSATE TO SPLASH BLOCK ON ROOF.
6. PROVIDE AIR BALANCE AND COMMISIONING REPORT.
7. VERIFY ALL DUCT DIMENSIONS PRIOR TO INSTALLATION.'
S. ALL DUCT DIMENSIONS ARE CLEAR INSIDE DIMENSIONS.
9 INSULATE ALL DUCT PER WSEC TABLE 14 -5.
10. SEAL ALL DUCT PER WSEC.
HVAC Equipment Schedule
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JUL 2 0 2011
✓e
City of kwila
BUILDING IVISIQN
Unit #
Brand
Pv ?odei
Ton
CFM
OSA
EconP
Oa . Cool
SEER
Cap. Hest
Strip Heat
Weight
Dba
Location
HP -1
Carrier
50TCQA06
5.0
2000
300
0-100
0.5
61,300
13.2
58,400
11.5KW
831#
80
Roof
ROOF ACCESS "ADJACENT TENANT"
a
PARTIAL ROOF PLAN
(E) HP -2 "NO WORK"
WHSE
OFFICE
(E) CU'S "NO WORK" (TYP 3)
HP -1
E) HP -3 "NO WORK"
REVISIONS
No changes shall be made to the scope
of work without prior approval of
Tukwila Building Division.
NOTE: Envisions will require a new plan submittal
and may include additional plan review fees.
FILE PY
Permit No. M. I.1 —090 ,
PIE review approval is subject to errors and omissions.
Approval of construction documents does not auth ; ize
talc violafio , f a dopted code or ordnance. G ' c .pt
of � pprov ° Id'•'� p and conditions is atrknowdet g p: °
ii 1
o®1',I'
By
Date:
City Of Tukwila
BUILDING DIVISION
MUO98
RECEIVED
JUL 13 2011
PERMIT CENTER
REV I S I ONS
v
MECHANICAL,
COMFORT
F. 425.251.9871
c
L.L..
0 00
•00
r
W
Q Q
U0
WQ
W
2 2
co
Q
DATE:
SCALE:
DRAWN:
CHECKED:
JTS
M1
00 -000