Loading...
HomeMy WebLinkAboutPermit M11-102 - WESTFIELD SOUTHCENTER MALL - SERVER ROOMWESTFIELD SERVER ROOM 2800 SOUThCENTER MALL Mi 1 -102 wq City oolukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206- 431 -2451 Web site: http: / /www.TukwilaWA.gov Parcel No.: 9202470010 MECHANICAL PERMIT Address: 2800 SOUTHCENTER MALL TUKW Project Name: WESTFIELD SERVER ROOM Permit Number: M11 -102 Issue Date: 08/02/2011 Permit Expires On: 01/29/2012 Owner: Name: Address: Contact Person: Name: Address: Email: WESTFIELD PROPERTY TAX DEPT PO BOX 130940 , CARLSBAD CA 92013 MICHAEL ATWOOD 9630 153 AV NE , REDMOND WA 98052 matwood@meritmechanical.com Contractor: Name: MERIT MECHANICAL INC. Address: PO BOX 2109 , REDMOND, WA 98052 Contractor License No: MERITMI163CM Phone: 425 883 -9224 X 1265 Phone: 425 883 -9224 Expiration Date: 06/01/2013 DESCRIPTION OF WORK: INSTALL (1) SPLIT SYSTEM HEAT PUMP AND AIR HANDLER FOR SERVER ROOM COOLING Value of Mechanical: $3,996.00 Type of Fire Protection: SPRINKLERS /AFA Electrical Service Provided by: Permit Center Authorized Signature: Fees Collected: $233.13 International Mechanical Code Edition: 2009 Date: a -a-- i 1 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this permit. Nzo Signature: Date: ` C11 Print Name: �" lU}'L A-71, j( °I This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -4/10 M11-102 Printed: 08 -02 -2011 • • PERMIT CONDITIONS Permit No. M11-102 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: Readily accessible access to roof mounted equipment is required. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431- 3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IMC -4/10 M11 -102 Printed: 08 -02 -2011 CITY OF TUKWIL -. Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://vvww.ci.tukwila.wa.us Mechanical Permit No. 02- No. (Faro ce use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *please print ** Site Address: Z g t Se ,tc ilJrr-A_ King Co Assessor's Tax No.: Z( l ' 1 DO/ U Suite Number: Floor: Tenant Name: WEs7Ft 14i•4.•- S A/C _ tafxrY, New Tenant: ❑ Yes No Property Owners Name: 1.44 S rif- -/C- . (-1.4 Mailing Address: `33 So4■Tbk'.6wT) A.. C1 rt. �L, City 1rid8 State Zip CONTACT PERSON — who do, we yo' s ready to be issued Name: Mailing Address: _ City �+ State Zip E -Mail Address: V 'k*iD 7 © lrrk EC14€44/16F4 -. Glifo aax Number: (4'1Z 3 7 YG7-0 qll Z Day Telephone: G ECHANICAL CONTRACTOR INFO I(i MATION Company Name: (14E4€4.7" 101C0.I,tA.N, e 44- 0 /rad ''G Mailing Address: 3o In-to ��� 'V4 Contact Person: '5 441 E 45 WN.T f t,"` *:td NF - E-Mail Address: / Contractor Registration Number: i1f1,f�t rA4 f 1�3 d# City Day Telephone: Fax Number: Expiration Date: «/`O / /Zd / 3 State %WS Zip ARC TE T OF RECORD All plans must be star sped by architect of record Company Name: Mailing Address: City Contact Person: Day Telephone: Fax Number: E -Mail Address: State Zip ENGINEER OF RECORD — All pl Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: State Zip HAApplications\Forms- Applications On Line \2010 Applications \7 -2010 - Mechanical Permit Application Revised'. 7 -2010 bh Page 1 of 2 Valuation of project (contractor's bid price): $ 31 9 f` . oz.) Scope of work (please provide detailed information): %4Jp 4, t.. 144IVotJ - Foot ,t atefs..,-1 (-40I> L ci • Use: Residential: New Commercial: New Fuel Type: Electric Replacement Replacement Gas ❑ Other: Indicate type of mechanical work being installed and the quant'ty below: Unit Type: Qty Unit Type: Qty Unit Type: Qty Bioler /Compressor Qty furnace <100k btu air handling unit >10,000 cfm fire damper 0 -3 hp /100,000 btu 6) furnace >100k btu evaporator cooler diffuser 3-15 hp /500,000 btu floor furnace ventilation fan connected to single duct thermostat 15 -30 hp /1,000,000 btu suspended/wall/floor mounted heater ventilation system wood/gas stove 30 -50 hp /1,750,000 btu appliance vent hood and duct emergency generator 50+ hp/ 1,750,000 btu repair or addition to heat/refrig/cooling system Incinerator — domestic other meical equipmenchant air handling unit <10,000 cfm (I) incinerator — comm /ind PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 international building code (current edition). 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDIN OWNER O' ;, THO D AGENT: Signature: Print Name: AlIchitEk. AT 4Db1 Mailing Address: Quit /5"3 R.O 41/IC Date Application Accepted: 0112,01u Date: kb12p 11 Day Telephone: /?/c, 7Z.2, 4.20tVrvito 1.414k— City State Zip Date Application Expires: a t 70 11z- Staff Initials: )� H:\Applications\Forms- Applications On Line \2010 Applications \7 -2010 - Mechanical Permit Application doc Revised: 7 -2010 bh Page 2 of 2 0 �J���,�Awq� City of Tukwila C y O O 1908 • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: / /www.TukwilaWA.gov RECEIPT Parcel No.: 9202470010 Permit Number: M11 -102 Address: 2800 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 07/20/2011 Applicant: WESTFIELD SERVER ROOM Issue Date: Receipt No.: R11 -01518 Payment Amount: $233.13 Initials: JEM Payment Date: 07/20/2011 11:56 AM User ID: 1165 Balance: $0.00 Payee: MERIT MECHANICAL, INC. TRANSACTION LIST: Type Method Descriptio Amount Payment Check 24497 233.13 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts MECHANICAL - NONRES PLAN CHECK - NONRES 000.322.102.00.00 186.50 000.345.830 46.63 Total: $233.13 doc: Receipt -06 Printed: 07 -20 -2011 INSPECTION RECORD Retain a copy with permit M I (- / c3 7 INSPECTION NO. PERMIT NO. it( CITY OF TUKWILA BUILDING DIVISION C K. (206) 431 -3670 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 431 -2451 Prik f 1 �,O se v`:TYp rl pectjpn: II .e_.A •+�,.� Address: �^ ,(� Date Called: j , �` , /�,� Special Instructions: 64-5- Date Wanted 1 q _'( ./ 1 p.m. Requester: PhecirT .5 -- V —2 71. Approved per applicable codes. El Corrections required prior to approval. COMMENTS: Veriqj'Y h,1 w7 1 Inspector( Date 11 L ❑ REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. • INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION •.6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 1 Proj�ec_ 1t: ; . v Vtif ) Ty p,of Inspecttiion': ` pO / 14-R-14` t!j KJ �i/ Address: Date Called: d JeA p cJJ , Special Instructions: . • . Date Wanted: — �, {/ rn 1 p.m. Requester: Ph i(o;o ZQy _ Z 4 .7,1 Approved. per applicable codes. D Corrections required prior to approval. COMMENTS: 17,Cr d JeA p cJJ , k re prop ;. -P A 40-N ' a & @ C. . 1 ..Sk Pi") v L1 3-N Aii 13$ . - i-re LA L.) ).-)9,-(0 lInsp ctor: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. l HERMIT COORD COPI° PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M11 -102 DATE: 07/20/11 PROJECT NAME: WESTFIELD SERVER ROOM SITE ADDRESS: 2800 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued Building Division im Public Works Fire Prevention Structural Planning Division Permit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete 14 Incomplete n DUE DATE: 07/21/11 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required No further Review Required Ni REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 08/18/11 Approved Approved with Conditions Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 Contractors or Tradespeople P ter Friendly Page • General /Specialty Contractor A business registered as a construction contractor with LIi1 to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name MERIT MECHANICAL INC OBI No. 600517946 Phone 4258839224 Status Active Address 9630 153Rd Avenue Ne License No. MERITMI163CM Suite /Apt. License Type Construction Contractor City Redmond Effective Date 2/14/1984 State WA Expiration Date 6/1/2013 Zip 98052 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status AUTOMMC044QH AUTOMATED MECH CONTROLS INC Construction Contractor General Unused 11/8/1996 6/1/2010 Expired Business Owner Information Name Role Effective Date Expiration Date KIRKWOOD, RODERICK V President 02/14/1984 Bond Amount KIRKWOOD, JOAN M Secretary 02/27/2006 08358695 FRICKBERG, WILLIAM MICHAEL Vice President 02/27/2006 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 10 FIDELITY Et DEPOSIT CO OF MD 08358695 02/01/2010 Until Cancelled $12,000.00 01/20/2010 9 ARCH INS CO SU1041124 02/01/2009 Until Cancelled 02/01/2010 $12,000.00 01/12/2009 8 TRAVELERS CAS SURETY CO 0815103546895BCM 07/22/2001 Until Cancelled 02/01/2009 $12,000.0003/07 /2002 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 26 CEOXINGTON INS 014180670 11/01/2010 11/01/2011 $2,000,000.00 10/29/2010 25 CEOXINGTON INS 049159165 11/01/2009 11/01/2010 $2,000,000.0011 /02/2009 24 LEXINGTON INS 004052434 11/01/2008 11/01/2009 $2,000,000.0011 /04/2008 23 ACE AMERICAN HD0G23734941 03/03/2008 03/03/2009 $2,000,000.00 03/10/2008 22 CONTINENTAL WESTERN INS CO CWP2545786 11/01/2007 11/01/2008 $1,000,000.0010 /31/2007 21 CONTINENTAL WESTERN INS CO CWP2545786 11/01/2005 11/01/2007 $1,000,000.0010 /18/2006 20 CONTINENTAL WESTERN INS CO CWP2545786 11/01/2004 11/01/2005 $1,000,000.0011 /01/2004 https://fortress.wa.gov/lni/bbip/Print.aspx 08/02/2011 RECEIVED CITY OF TUKWI JUL 20 20'1 PERMIT CENTER HEAT PUMP UNIT SCHEDULE TAG MAKE & MODEL DESCRIPTION SERVING COOLING, MBH HEATING, MBH REGRIG. PIPE OUTDOOR FAN SOUND COMPRESSOR ELECTRICAL WEIGHT REMARKS TOTAL SEER TOTAL HSPF LIQ. SUCT. FLA DRIVE dBA TYPE VOLT PH MCA MOCP LBS HP -1 SANYO CH1271 1 TON CONDENSING UNIT SERVER ROOM 11.9 17.0 13.0 9.3 1/4 3/8 0.6 DIRECT 49 DC IN ROTARVERTER Y 115 1 20 20 78 1, 2 NOTES: 1. EQUIPMENT MAY BE SUBSTITUTED FOR EQUAL OR BETTER MANUFACTURER. 2. LOW /HI PRESS SWITCH, CRANKCASE HEATER, LOW AMBIENT. AIR HANDLER SCHEDULE TAG MAKE & MODEL DESCRIPTION SERVING FAN ELECTRICAL WEIGHT REMARKS CFM ESP RPM FLA VOLT PH MCA MOCP LBS AH -1 SANYO KHS1271 DUCTLESS AIR HANDLER SERVER ROOM 294 - HI 0.35 115 1 - - 20 1, 2 NOTES: 1. EQUIPMENT MAY BE SUBSTITUTED FOR EQUAL OR BETTER MANUFACTURER. 2. AH -1 POWER BY HP -1. PUMP SCHEDULE SYM MAKE & MODEL DESCRIPTION PUMP ELECTRICAL HVAC 2ND FLOOR PLAN HEAD FT REMARKS SUCTION DISCHARGE VOLT PH WATT GPH P -1 UMPET LIM4000 CONDENSATE PUMP 1/4 1/4 115 1 30 3.1 50 NOTES 1. EQUIPMENT MAY BE SUBSTITUTED FOR EQUAL OR BETTER MANUFACTURER. GENERAL NOTES 1. THERMOSTAT (SANYO WIRELESS REMOTE CONTROL) PROVIDED WITH EQUIPMENT. 2. FIELD VERIFY UNIT LOCATIONS, DROPS, AND POSITIONS. 3. INSULATE DUCT PER W.S.E.C. 4. A 120 -VOLT RECEPTACLE SHALL BE WITHIN 25' OF EACH PIECE OF EQUIPMENT. DISCONNECT BY ELECTRICAL CONTRACTOR. 5. ALL LINE VOLTAGE BY ELECTRICIAN. 6. 3/4" PVC CONDENSATE DRAIN WITH TRAP DISCHARGED ON SPLASH BLOCKS. USE COPPER PIPING FOR ABOVE HARD LID CEILING. 7. PROJECT MANAGER TO VERIFY LENGTH OF REFRIGERATION PIPING FOR LINE SIZES AND TRAPS AS PER MANUFACTURERS REQUIREMENTS. 8. HVAC SYSTEM IS DESIGNED PER 2009 WSEC, IBC, AND IMC. F1 macys uvri [1 SCOPE OF WORK 1. INSTALL 1 SPLIT SYSTEM HEAT PUMP UNIT. 2. INSTALL 1 SPLIT SYSTEM DUCTLESS AIR HANDLER UNIT. 3. INSTALL 1 CONDENSATE PUMP. SEAFOOD CITY 1 L ill O 0 MIK LOCATION OF WORK / \ SITE PLAN SCALE: NONE VICINITY MAP tik%i r /a. p , Southcenter Mall,' Sdwit?hc+eft€ JCPenney .wn LEGAL DESCRIPTION POR OF NW 1/4 OF SE 1/4 - BEGIN NE CORNER OF SE 1/4 TH N 88 -05 -42 W 1998.68 FT TO W MGN OF E 659.34 FT OF NW 1/4 OF SE 1/4 & POB TH S 01 -47 -29 W 658.25 FT TH N 88 -00 -36 W 673.30 FT TO W MGN OF NW 1/4 OF SE 1/4 TH N 01 -12 -25 E 657.29 FT TO NW COR OF NW 1/4 OF SE 1/4 TH S 88 -05 -42 E 680 FT TO POB TAX PARCEL NUMBER: 262304 -0010 SEPARATE PERMIT REQUIRED FOR: d Mechanlaad OrtIectrical O'hlumbing Ci'Gras Piping City of Tukwila DIVISION REVISIONS No chr.noes shall be made to the scope of S '.•ork without prior approval of i-c ! ;,,vita Building Division. NOTE: F -1117.7i():15' will require a new plan submittal and m _, ± =dude additional plan review fees. j L_ BUILDING INFORMATION ZONING: TUC CONSTRUCTION TYPE: - OCCUPANCY TYPE: M, B OWNER WEA SOUTHCENTER, LLC 633 SOUTHCENTER SEATTLE, WA 98188 32 15/32" J DIMENSIONS FOR AH -1 SCALE: NONE (UNIT DEPTH =7- 7/16") 1 DIMENSIONS FOR HP -1 SCALE: NONE (UNIT HEIGHT =21- 9/16") COMPLETION AND COMMISSIONING FOR MECHANICAL SYSTEMS RECORD DRAWINGS OF ACTUAL INSTALLATION SHALL BE PROVIDED TO THE BUILDING OWNER WITHIN 90 DAYS OF THE DATE OF SYSTEM ACCEPTANCE PER WASH. STATE ENERGEY CODE (WSEC) SECTION 1416.1 (2006 EDITION) AN OPERATION MANUAL AND MAINTENANCE MANUAL SHALL BE PROVIDED TO THE BUILDING OWNER PER WSEC SECTION 1416.2.4.2 (2006 EDITION) ALL HVAC SYSTEMS SHALL BE BALANCED AND A WRITTEN BALANCE REPORT SHALL BE PROVIDED TO THE OWNER PER WSEC SECTION 1416.2.2. (2006 EDITION) HVAC CONTROL SYSTEM SHALL BE TESTED, CALIBRATED AND ADJUSTED, SEQUENCES OF OPERATION SHALL BE TESTED TO ENSURE THAT THEY OPERATE IN ACCORD WITH SPECIFICATIONS AND APPROVED PLANS, AND COMPLETE REPORT OF TEST RESULTS SHALL BE FILED WITH THE OWNER PER WSEC SECTION 1416.2.3.2 AND 1416.2.5. (2006 EDITION) FT y!rfla, C Permit No. Plan review approval is sub t to errors and omissions. Approval of construction documents does not authorize t oration of any adopted code or ordinance. Receipt i pproved Field Cbp and is acknowledged: BY Die: *.i1(.�1 City Of lbkwila BUILDING DIVISION ABBREVIATIONS ABV. ABOVE A.D. ACCESS DOOR A.P. ACCESS PANEL A.F.F. ABOVE FINISHED FLOOR AH AIR HANDLING UNIT BF BELOW FLOOR BFC BELOW FINISHED CEIUNG BOT BOTTOM CIP CAST IN PLACE CLG CEILING CD CEILING DIFFUSER CG CEILING GRILLE CTG CEILING TRANSFER GRILLE CONC. CONCRETE CONN. CONNECTION CFM CUBIC FEET PER MINUTE DIFF. DIFFUSER DIA. DIAMETER DN DOWN DWG. DRAWING DB DRY BULB EA. EACH ENT. ENTERING EAT ENTERING AIR TEMPERATURE EWT ENTERING WATER TEMPERATURE EQUIP EQUIPMENT EXH EXHAUST ESP EXTERNAL STATIC PRESSURE FLR FLOOR FT. FOOT or FEET FPM FEET PER MINUTE FUT. FUTURE GALV. GALVANIZE GR. GRILLE HWG HIGH WALL GRILLE HWTG HIGH WALL TRANSFER GRILLE HT. HEIGHT HP HORSEPOWER HWS HOT WATER SUPPLY HWR ID IE IN. WG HOT WATER RETURN INSIDE DIAMETER /DIMENSION INVERT ELEVATION INCHES W.G. LIN. DIFF. UNEAR DIFFUSER UN. FT. LINEAR FEET /FOOT LWG LOW WALL GRILLE LWR LOW WALL REGISTER MAX. MAXIMUM MBH 1000 BRITISH THERMAL UNITS MIN. MINIMUM MOT. DPR. MOTORIZED DAMPER MTD N.C. N.O. OSA OBD OD PCF POC PSI PSIG RPBP RFA REG. MOUNTED NORMALLY CLOSED NORMALLY OPEN OUTSIDE AIR OPPOSED BLADE DAMPER OUTSIDE DIAMETER /DIMENSION POUNDS PR CUBIC FOOT POINT OF CONNECTION POUNDS PER SQUARE INCH POUNDS PER SQUARE INCH GAUGE REDUCED PRESSURE BACKFLOW PREVENTOR RELIEF AIR REGISTER REQ'D REQUIRED RA RETURN MR SQ. FT. SQUARE FEET SA SUPPLY AIR S.L. TDH TG TOT TYP VTR WB WG W/ W/O SOUND LINED TOTAL DYNAMIC HEAD TRANSFER GRILLE TOTAL TYPICAL VENT THROUGH ROOF WET BULB WATER GAUGE WITH WITHOUT DUCTWORK - LEGEND 0 ►off � C.= 0 R - 100 S 100 E - 100 - - SLSM =3111M * FC 1 SFD FD VD E MD VD A J MIN AIR FLOW DIRECTION SUPPLY OR OSA DUCT SECTION UP OR TOWARD ROUND, RECTANGULAR RETURN, RELIEF OR EXHAUST DUCT SECTION UP OR TOWARD ROUND, RECTANGULAR SUPPLY OR OSA DUCT SECTION DOWN OR AWAY ROUND, RECTANGULAR RETURN, RELIEF OR EXHAUST DUCT SECTION DOWN OR AWAY ROUND, RECTANGULAR ROUND DUCT SYMBOL RETURN AIR; NUMBER INDICATES CFM QUANTITY SUPPLY AIR; NUMBER INDICATES CFM QUANTITY EXHAUST AIR; NUMBER INDICATES CFM QUANTITY SOUND LINED SHEET METAL FLEXIBLE EQUIPMENT CONNECTION SMOKE /FIRE DAMPER FIRE DAMPER VOLUME DAMPER MOTORIZED DAMPER TURNING VANES ROUND TO ROUND 45' F REVIEWED FOR CODE COMPLIANCE APPROVED IJUL 2 7 2011 City of Tukwila SUILDING DIVISION SQUARE TO SQUARE 45' FITTING SQUARE TO ROUND 45 FITTING 45 FITTING FOR DUCTWORK GENERAL - LEGEND ICY NEW EQUIPMENT, DUCTWORK, AND GRILLES EXISTING EQUIPMENT, DUCTWORK, AND GRILLES - DETAIL OR DIAGRAM NUMBER - SHEET NUMBER WHERE DETAIL /DIAGRAM SHOWN C7� SECTION LETTER SHEET NUMBER WHERE SECTION SHOWN REVISION CLOUD & CHRONOLOGICAL NUMBER DETAIL REFERENCE OUTLINE POINT OF CONNECTION THERMOSTAT DRAWING INDEX DRAWING NO. DRAWING TITLE M -0.1 LEGEND, SCHEDULE, AND GENERAL NOTES -HVAC M -2.0 HVAC 2ND FLOOR PLAN M -2.1 HVAC ROOF PLAN COPYRIGHT NOTICE THIS LAYOUT /DESIGN IS AN UNPUBLISHED WORK, AND MERIT MECHANICAL HEREBY RESERVES ITS COMMON LAW RIGHT, PURSUANT TO TITLE 17 SECTION 2 OF THE USA CODE TO PREVENT ANY UNAUTHORIZED COPYING, PUBLICATION OR USE OF THIS DESIGN, AND TO OBTAIN DAMAGES THEREFORE. 2800 SOUTHCENTER TUKWILA WA, 98188 MERIT MECHANICAL INC. 9630 153RD AVENUE NE P.O. BOX 2109 REDMOND, WA 98073 -2109 (425) 883 -9224 FAX (425) 867 -0962 LICENSE: MERITMI163CM REVISIONS 1. ISSUED FOR PERMIT 07 -15 -11 DESIGNED VTD CHECKED AEA DATE 07 -14 -11 JOB NUMBER 276983 SHEET COVER SHEET SHEET NUMBER kk1L1O2 mV} • STOREFRONT ENTRANCE BELOW HVAC 2ND FLOOR PLAN SCALE: 1 /e = 1' - 0" REVIEWED FOR CODE COMPLIANCE APPROVED 'JUL 2 7 2011 City of Tukwila BUILDING DIVISION i RECEIVE° CITY OF TUKWILA JUL 2 0 2011 PERMIT CENTER COPYRIGHT NOTICE THIS LAYOUT /DESIGN IS AN UNPUBLISHED WORK, AND MERIT MECHANICAL HEREBY RESERVES ITS COMMON LAW RIGHT, PURSUANT TO TITLE 17 SECTION 2 OF THE USA CODE TO PREVENT ANY UNAUTHORIZED COPYING, PUBLICATION OR USE OF THIS DESIGN, AND TO OBTAIN DAMAGES THEREFORE. 2800 SOUTHCENTER TUKWILA WA, 98188 MERIT MECHANICAL INC. 9630153RD AVENUE NE P.O. BOX 2109 REDMOND, WA 98073 -2109 (425) 883 -9224 FAX (425) 867 -0962 LICENSE: MERITMI163CM REVISIONS 1. ISSUED FOR PERMIT 07 -15 -11 DESIGNED VTD CHECKED AEA DATE 07- 14 -11. JOB NUMBER 276983 SHEET TITLE HVAC 2ND FLOOR PLAN SHEET NUMBER M2.0 2 -0F -3 COPYRIGHT NOTICE THIS LAYOUT /DESIGN IS AN UNPUBLISHED WORK, AND MERIT MECHANICAL HEREBY RESERVES ITS COMMON LAW RIGHT, PURSUANT TO TITLE 17 SECTION 2 OF THE USA CODE TO PREVENT ANY. UNAUTHORIZED COPYING, PUBLICATION OR USE OF THIS DESIGN, AND TO OBTAIN DAMAGES THEREFORE. Wo'" 2800 SOUTHCENTER TUKWILA WA, 98188 R Ai OF ;CESS ITCH REFER UP FRdM BELOW MERIT MECHANICAL INC. 9630 153RD AVENUE NE P.O. BOX 2109 REDMOND, WA 98073 -2109 FAX (42 8 5) 867-0962 LICENSE: MERITMI163CM REVISIONS 1. ISSUED FOR PERMIT 07 -15 -11 DESIGNED VTD CHECKED AEA. DATE 07 -14 -11 JOB NUMBER 276983 SHEET TITLE HVAC ROOF PLAN SHEET NUMBER M2.1 3 -OF -3