HomeMy WebLinkAboutPermit M11-106 - WESTFIELD SOUTHCENTER MALL - APPLE STOREAPPLE STORE 801 SOUTHCENTER BL Mi 1 -106 City 4lukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov MECHANICAL PERMIT Parcel No.: 9202470010 Address: 801 SOUTHCENTER MALL TUKW Project Name: APPLE STORE Permit Number: M11 -106 Issue Date: 08/24/2011 Permit Expires On: 02/20/2012 Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA 92013 Contact Person: Name: DUAE SIEFERTSON Address: 1916 220 ST SE, STE M101 , BOTHELL WA 98021 Email: duanes @pacificaircontrol.com Contractor: Name: PACIFIC AIR CONTROL INC Address: 11812 N CREEK PKWY N 104 , BOTHELL WA 98011 Contractor License No: PACIFAC230P8 Phone: 206 510 -7837 Phone: Expiration Date: 10/01/2011 DESCRIPTION OF WORK: DUCT MODIFICATION TO ADD DDC WT CONTROLS TO THE EXISTING DUCT SYSTEM IN THE OFFICE PORTION IN BACK OF THE RETAIL PORTION. WORK INCLUDES ADDING (6) ZONE DAMPERS WITH LOW VOLTAGE CONTROL, ADDING (3) SUPPLY DIFFUSERS, AND CHANGING (1) SUPPLY DIFFUSER. Value of Mechanical: $7,500.00 Type of Fire Protection: SPRINKLERS /AFA Electrical Service Provided by: Permit Center Authorized Signature: Fees Collected: $281.56 International Mechanical Code Edition: 2009 Date: 9•11-(`' ( I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this permit. Signature: M R Date: ?)/e)`14 ,10) ) Print Name: V N(t ) 1? �2( O (\i This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -4/10 M11 -106 Printed: 08 -24 -2011 • • PERMIT CONDITIONS Permit No. M11-106 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 -3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IMC -4/10 M11 -106 Printed: 08 -24 -2011 CITY OF TUKl.,LA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto://www.TukwilaWA.dov Building Permit No. Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No. No. (For ofce use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: Southcenter-Parkway--Aft Tenant Name: Apple Store Property Owners Name: Westfield Southcenter Mailing Address: 2800 Southcenter Mall King Co Assessor's Tax No.: 920247 -0010 Suite Number: 801 Floor: 1st New Tenant: ❑ Yes .. No Tukwila WA 98188 City State Zip CONTACT PERSON — who do e contact when your permit is ready to be issued' Name: Duane Siefertson Mailing Address: 1916 220th Street SE, Suite M101 E -Mail Address: duanes @pacificaircontrol.com Day Telephone: Bothell City (206) 510 -7837 WA 98021 State Fax Number: (206) 340 -2270 Zip GENERAL CONTRACTOR INFORMATION (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: Pacific Air Control Mailing Address: 1916 220th Street SE, Suite M101 Contact Person: Duane Siefertson Bothell WA 98021 E -Mail Address: duanes @pacificaircontrol.com Contractor Registration Number: PACIFAC230P8 City State Day Telephone: (206) 510 -7837 Fax Number: (206) 340 -2270 Zip Expiration Date: 12/31/2011 ARCHITECT OF RECORD All plans must be stamped by Architect of Record Company Name: None Mailing Address: City Day Telephone: Fax Number: Contact Person: E -Mail Address: State Zip ENGINEER OF RECORD — All plans must be s mped by Engineer of Record Company Name: Pacific Air Control Mailing Address: 1916 220th Street SE, Suite M101 Contact Person: Don Lo Bothell WA 98021 E -Mail Address: donl @pacificaircontrol.com 11: Applications. Forms- Applications On Line 2010 Applications 7 -2010 - Petmit Application.doc Revised: 7 -2010 hh City State Day Telephone: (206) 682 -6393 Fax Number: (206) 340 -2270 Zip Page 1 of 6 MECHANICAL PERMIT INFORMATION - 306 -431 -3670 MECHANICAL CONTRACTOR INFORMATION Company Name: Pacific Air Control Mailing Address: 1916 22oth Street SE, Suite M101 Tukwila WA 98021 Contact Person: Duane Siefertson E -Mail Address: duanes @pacificaircontrol.com City State Day Telephone: (206) 510 -7837 Fax Number: (206) 340 -2270 Zip Contractor Registration Number: Expiration Date: 12/31/2011 Valuation of Mechanical work (contractor's bid price): $ � O Scope of Work (please provide detailed information): D 1) ur n10 C7 t pi C.4f r' 100 TO 4D b --1) 0 L Irt. 7"`R -0LS 'Y" O -714E, ' 1 EN.11S i )'S 11f E.n-) 13-) J ?'u Pa Wt..) 1 N f rc K_. o0r- 714E. 1213-At ,S , NP•to tho S MOW, ---AG E 42P1t5 taw vote t ,s- Co L ADO (3) Sk) - uS€its AN 4; O Akin,., (/) azf v SEAR Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New .... ❑ Replacement .... ❑ Fuel Type: Electric ❑ Gas .... ❑ Other: Indicate type of mechanical work being installed and the quantity below: Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace <100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace >100K BTU Evaporator Cooler Diffuser 4 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat D0L, SEss 7 15 -30 HP /1,000,000 BTU Suspended /Wall /Floor Mounted Heater Ventilation System Wood /Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP/I,750,000 BTU Repair or Addition to Heat /Refrig /Cooling System Incinerator - Domestic Other Mechanical Equipment ' - cpf.yT,QpL toms j LYE ` 1'YlT R " "�'9 Air Handling Unit <10,000 CFM Incinerator Comm /Ind i -T- IZAKISF.orzi 1Gag_. 1-1:`. Applications,Fonns- Applications On Line \2010 Applications :.7 -2010 - Permit Application.doc Revised: 7 -2010 bh Page 4 of 6 PERMIT APPLICATION NOTES - Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHRIZED AGENT: Signature: "vt. 0 Print Name: 4 IE. J1E. PE. R.'i'SoN Day Telephone: Mailing Address: ➢ et L-lo o`Z.ge'N 51% SS 1 . Ib 1 13oTWIEu- City Date Application Accepted: 01 V\ \ ■ Date: 1 C X41) as -' 3O — `I83'7 State Zip Date Application Expires: oLlzM tLApplications :Fonns- Applications On Line;2010 Applications \7 -2010 - Permit Application.doc Revised: 7 -2010 bh Staff Initials: % Ly Page 6 of 6 Cal of Tukwila, • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: //www. ci. tukwila. wa. us SET RECEIPT RECEIPT NO: R11 -01612 Initials: JEM Payment Date: 07/29/2011 User ID: 1165 Total Payment: 477.26 Payee: PACIFIC AIR CONTROL, INC. SET ID: 0729 SET NAME: PACIFIC AIR SET TRANSACTIONS: Set Member EL11 -0700 M11 -106 TOTAL: Amount 195.70 281.56 195.70 TRANSACTION LIST: Type Method Description Amount Payment Check 16424 477.26 TOTAL: 477.26 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR MECHANICAL - NONRES PLAN CHECK - NONRES 000.322.101.00.0 000.322.102.00.0 000.345.830 195.70 225.25 56.31 TOTAL: 477.26 INSPECTION NO. INSPECTION RECORD Retain a copy with permit AA t( 10 — P y P PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Proj ct: �P��- ��- Type of lnspecti n: F.u±( Meci.. Adcesb 1 Sc AO" i Date Called: Special Instructions: 0 5 4s -i _ °I 'X 0 -Z6yt G hA ens 5 v 1 Q, vSei$ � ,�.r.4 E � PA Date Wanted:. 1 0 ` r 8-1( �� p.m. Requester: Phone Not; _.. / C�.� ...,s,‘? 4 Approved per applicable codes. • Corrections required prior to approval. COMMENTS: CalE4 &s (A-A(L R.170 v,ry r 14 '1AI (Inspector: Dal:o _(cc.. (/ n REINSPECTION.FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. • • CiTY. OP TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 ds (206) 431-3670 Permit Irit'pection Request Line (206) 431-2451 • Tr■ • .• • .• PERMIT NO. —... .. PrOject: .- .. . - Type of Insoectiori: ray.) 4 L, •Corrections required prior to approval. Address: ' . ekf) Yr A I 1 Date Called: .fy‘ LOMMENTS• Special Instructions: . • • • • . . Date Wanted: CI — 1 to 1.-11 p.m. Requester: Phone No: .)g,e( tor. SPECTION FEE RE JARED. Prior to ext inspection. fee must be id at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. AIRTEST Co.� Inc. Warranty of TAB Services PROJECT: Westfield Southcenter — Apple Store Suite #801 LOCATION: Tukwila, WA PROJECT #: 11- 3031 -1 DATE: 9/13/2011 TECHNICIAN: Mike Touchette Warranty of TAB Services: AIRTEST Co., Inc. warranties the TAB work performed on this project for one year from the date of the first published report. AIRTEST Co., Inc. reserves the right to correct errors or omissions in the collection of data, and issue amended TAB reports. This Warranty covers all Test and Balance services provided by AIRTEST unless otherwise stated in writing. When any balancing issues or concerns arise, AIRTEST Co., Inc. will dedicate resources to understand the issue or question. This may include a return trip(s) to the project site, or other appropriate methods of resolving the issue. A return trip(s) to the site, if necessary, will involve verification of system adjustments and adherence to reported values. No charges will be issued for any work found to be in compliance with the reported data, however if AIRTEST Co., Inc. is directed to make adjustments that result in differences from the reported data (i.e. Comfort Balancing), charges may be incurred. Repeated requests for Warranty services may incur charges if the TAB work is found to be in compliance with the reported data. Voided Warranty and Additional Charges: When issues arise due to mechanical equipment failure, control or maintenance related causes, the return trip may be subject to a service charge not covered under warranty. AIRTEST Co., Inc. reserves the right to resolve any TAB issues. Actions by others to resolve a warranty issue before AIRTEST Co., Inc. is notified, or allowed sufficient time to respond, will result in a voided project warranty. Any return trip(s) to the jobsite as a result of such actions are subject to charges. A purchase order will be required before returning to the jobsite if such conditions exist. Document Archiving: An electronic copy of the test data will be provided at no charge for the warranty period. Electronic copies of the project test data may be available after the warranty period, at no charge. Printed / bound copies will be subject to a fee. P.O. Box 86 • Issaquah, Washington 98027 • (425) 313 -0172 • Fax (425) 313 -5735 5 of 8 AIRIEST Co., Inc. Calibration Report PROJECT: Westfield Southcenter - Apple Store Suite #801 LOCATION: Tukwila, WA PROJECT #: 11- 3031 -1 DATE: 9/13/2011 TECHNICIAN: Mike Touchette t ss4 i' ;' INSTjRUMENLT�I SERIAL;NUMBER �t hli y ESJOF IJSE • x' CALIBRA *TioN - y,•RXax,•� TjESTTDAT,Ef u _ PACER DA400 / 1014147 Velocity Sep -11 11/10 Alnor Balometer 6463 / 70634301 CFM Sep -11 1/11 Alnor EBT -720 / 90634003 Pressure Sep -11 1/11 SHIMPO DT207L -S12 / D081 B0002 RPM Sep -11 4/11 VOM, Fluke T5-600 / 96202405 Electrical Sep -11 4/11 Alnor Micro M / 90524090 Temperature Sep -11 8/11 Alnor HM670 / 70633311 Hydronics Sep -11 8/11 SYMBQLS &FABBREV1ATI S ADJ = Adjustable Fan Speed CD = Ceiling Diffuser CFM = Cubic Feet per Minute DIA = VAV Inlet Dimension in Inches DD = Design Data EG = Exhaust Grille E.S.P. = External Static Pressure FIC = VAV Calibration Factor FCD = Field Collected Data FG = Floor Grille FLA = Motor Full Load Amps GPM = Gallons per Minute HP = Horsepower Hz = Hertz in. Hg. = Inches Mercury in. w.g. = Inches Water Gauge LD = Linear Diffuser LD x = Linear Diffuser where "x" is number of slots NIA = Not Available NI = Not Installed NR = Not Required NPSH = Net Positive Suction Head RG = Return Grille RPM = Revolutions per Minute SF = Motor Service Factor S.P. = Static Pressure SWG = Side Wall Grille T.S.P. = Total Static Pressure VAR = Variable Fan Speed 6 of 8 AI Th T Ca., Inc.. Heat Pump PROJECT: Westfield Southcenter - Apple Store Suite #801 LOCATION: Tukwila, WA PROJECT #: 11- 3031 -1 DATE: 9/13/2011 CONTACT: Mike Touchette SYSTEM/UNIT: HP -3 AREA: Apple Store #501 bysi t Al� �tIJa lf: }te=e` +e».•y .7.�Y{1 ?..... ti.. 3iia Unit Location Roof Unit Manufacturer Trane Unit Model Number WSC120 Unit Serial Number 837100102L Unit Serves Apple Store HP-3 / Fan HP-3 / Fan Fan Type 1 Class FC / I �'TestjData �4 SP Inlet Actual -.20 in. wc. SP Outlet Actual .66 in. wc. External SP Actual .86 in. wc. HP -3 / Fan HP-3 / Fan Fan RPM Actual 980 RPM aK Electri I Test Data T" ti a • ` ' . IFTestr Data. HP-3 / Fan Tot. GRD CFM Des. 3900 CFM Tot. GRD CFM Act. 3680 CFM Motor Volts 1 480 Volts Motor Volts 2 479 Volts Motor Volts 3 478 Volts Motor Amps 1 3.0 Amps Motor Amps 2 2.9 Amps Motor Amps 3 2.9 Amps Tested By: Mike Touchette Test Date: September 09, 2011 f ' =IIIIoto Daa�� �fi. 3,Y:}f'4�': e �d%2:k3i tt 4A ty� HP-3 / Fan Motor Manufacturer G.E. Motor HP 2.0 HP Motor RPM 1025 RPM Motor Frame 145T Motor Rated Volts 460 Volts Motor Phase 3 Motor Hertz 60 Hz Motor FL Amps 2.9 Amps Motor Service Factor 1.15 r � S ease Data ' _ HP-3 / Fan Drive Type Belt Belt Size A35 Number of Belts 1 Motor Sheave 1VL40 @ max Motor Sheave Bore 7/8 in. Fan Sheave AK64 Fan Sheave Bore 1 in. Sheave Center Line 11 in. ti a • ` ' . IFTestr Data. ; Tot. GRD CFM Des. 3900 CFM Tot. GRD CFM Act. 3680 CFM Fi Data HP-3 / Filter Filter Manufacturer Flanders Filter Type Pleated Filter Quantity 4 Filter Size 20x25x2 Airiest Co Inc 7 of 8 I RThST Co., Inc. Heat Pump PROJECT: Westfield Southcenter - Apple Store Suite #801 LOCATION: Tukwila, WA PROJECT #: 11- 3031 -1 114E1 DATE: 9/13/2011 CONTACT: Mike Touchette SYSTEM/UNIT: HP -3 (Cont.) AREA: Apple Store #501 HP -3 Supply Outlet Summary Tested By: Mike Touchette Test Date: September 09, 2011 j'1".Yite.E'g �, wv, !*'System /Unit n.'� �.ya� t'u en , Area Served <�� _ x Y ._ S — .m' Outlet Type '. E; $ ISizetLxW� °s .x"�";'1Sl Design ...xs ,-..., . " $ .�v' " Prelim; �eadh "gas jy Final mg ° , �/o "Final Deviation e ZD-1 -1 Hall CD 6 RD 100 50 85 85 ZD -1 -2 * Restroom CD 6 RD 75 50 85 113 ZD -1 -3 * Restroom CD 6 RD 75 55 80 107 ZD -1-4 Hall CD 6 RD 100 55 80 80 ZD -2 -5 Break Room RD 12 RD 550 180 500 91 ZD -2 -6 Break Room RD 12 RD 550 170 510 93 ZD -2 -7 Break Room RD 12 RD 550 250 510 93 ZD -3 -8 Office CD 8 RD 150 180 150 100 ZD -4 -09 Stock Room SWD 10 x 8 250 450 230 92 ZD -4 -10 Stock Room SWD 10 x 8 250 420 230 92 ZD -4 -11 Stock Room SWD 10 x 8 250 330 225 90 ZD -5 -12 Manager Office CD 16 RD 400 700 385 96 ZD -6 -13 Genius Room CD 12 RD 200 300 180 90 ZD -6 -14 Genius Room CD 12 RD 200 320 220 110 ZD -6 -15 Genius Room CD 12 RD 200 340 210 105 t� '' • Totals `f �S:^IBiSM} H� _ f .i..?Ji N3;r900(;85UF� aLl:w. €Y5'035,i�..£�i`.,m.T 11"1< 3380'7" HO�St���l� -u� 94 %�,� ��,�.YLTdK� * Notes HP -3 HP -3 HP -3 / ZD -1 -2 HP -3 / ZD -1 -3 8- Sep -11 Mike Touchette Bypass Damper Setting: .60" w.c. 8- Sep -11 Mike Touchette Zone Damper Settings: ZD -1= 100 %, ZD -2= 100 %, ZD- 3 =60 %, ZD- 4 =40 %, ZD- 5 =45 %, ZD -6 =75% 8- Sep -11 Mike Touchette No volume damper. 8- Sep -11 Mike Touchette No volume damper. Airiest Co Inc 8 of 8 AIRTEST Co., Inc. Certified Test, Adjust and Balance Report Project: Westfield Southcenter - Apple ,Suite B24 Address: 2800 Southcenter Mall Seattle, WA 98188 Engineer: Mechanical Contractor: Address: Pacific Air Control Pacific Air Control 11812 North Creek Parkway N., Suite 104 Bothell, WA 98011 TAB Supervisor: Brent K. Wyman NEBB Certification: 3000 Date: September 13, 2011 P.O. Box 86 • Issaquah, Washington 98027 • (425) 313-0172 • Fax (425) 313 -5735 1 of 8 AIRTEST Co., Inc. CERTIFICATION PROJECT: Westfield Southcenter - Apple, Suite B24 ADDRESS: Seattle, Washington THE DATA PRESENTED IN THIS REPORT IS A RECORD OF SYSTEM MEASUREMENTS AND FINAL ADJUSTMENTS THAT HAVE BEEN OBTAINED IN ACCORDANCE WITH THE CURRENT EDITION OF THE NEBB PROCEDURAL STANDARDS FOR TESTING, ADJUSTING, AND BALANCING OF ENVIRONMENTAL SYSTEMS. ANY VARIANCES FROM DESIGN QUANTITIES, WHICH EXCEED NEBB TOLERANCES, ARE NOTED IN THE TEST - ADJUST - BALANCE REPORT PROJECT SUMMARY. NEBB TAB FIRM: AIRTEST CO., INC. REG. NO. 3000 CERTIFIED BY: BRENT K. WYMAN DATE: September 13. 2011 SUBMITTED & CERTIFIED BY: NEBB TAB FIRM: AIRTEST CO., INC. TAB SUPERVISOR: BRENT K. WYMAN REG. NO. 3000 SIGNATURE: CERTIFICATION EXPIRATION DATE: March 31, 2013 P.O. Box 86 • Issaquah, Washington 98027 • (425) 313 -0172 • Fax (425) 313 -5735 2 of 8 a 3 - I 1 I p 111 a d =ppm :S110.13aXICI ittO cnwoa aaLual -1-1aD MON 000Eoj rittrdig chuviulaj ,bs-34.pur Etoz `tE yaAvpsc -cixz stualsfis- s7iuoy9fie JP zY ANIMIDSIG 3NI/A01103 aaLNI N0LLTJULL1133 fliraNT 10 avAutvau uoa SINEGWIlfibn TIV LAW Sial te-At verthvssi- *Xi/ `kulgditioji_LSIT_Luric XVIII MILIOD 01 SI SIRL unnannpal* a it a 1U11131401i:" IV) • Tee terrrtifirattatt THIS IS TO CERTIFY THAT Brent X. 'Wyman with 51.11Z11EST Company, Inc. in Issaquah, 'WA HAS MET ALL THE NEBB REQUIRENIENTS FOR NEBB CERTIFIED PROFESSIONAL STATUS IN 44cknics Systems FOR THE BOARD OF DIRECTORS: Exy. March v. 2013 AlltrEST-Corrapany, inc./WA NO. 3000 President NEBB Cert. No. President-Elect AIRTEST Co., Inc. Certified Test, Adjust and Balance Report Project: Westfield Southcenter - Apple ,Suite B24 Address: 2800 Southcenter Mall Seattle, WA 98188 Engineer: Mechanical Contractor: Address: Pacific Air Control Pacific Air Control C�OF�7UKtMLA SEP 7.9 2011 PERMITCEfy7gR 11812 North Creek Parkway N., Suite 104 Bothell, WA 98011 TAB Supervisor: Brent K. Wyman NEBB Certification: 3000 Date: September 13, 2011 itA I I - 10(1 P.O. Box 86 • Issaquah, Washington 98027 • (425) 313 -0172 • Fax (425) 313 -5735 AIRTEST Co., Inc. CERTIFICATION PROJECT: Westfield Southcenter - Apple, Suite B24 ADDRESS: Seattle, Washington THE DATA PRESENTED IN THIS REPORT IS A RECORD OF SYSTEM MEASUREMENTS AND FINAL ADJUSTMENTS THAT HAVE BEEN OBTAINED IN ACCORDANCE WITH THE CURRENT EDITION OF THE NEBB PROCEDURAL STANDARDS FOR TESTING, ADJUSTING, AND BALANCING OF ENVIRONMENTAL SYSTEMS. ANY VARIANCES FROM DESIGN QUANTITIES, WHICH EXCEED NEBB TOLERANCES, ARE NOTED IN THE TEST - ADJUST - BALANCE REPORT PROJECT SUMMARY. NEBB TAB FIRM: REG. NO. 3000 AIRTEST CO., INC. CERTIFIED BY: BRENT K. WYMAN DATE: September 13, 2011 SUBMITTED & CERTIFIED BY: NEBB TAB FIRM: AIRTEST CO., INC. TAB SUPERVISOR: BRENT K. WYMAN REG. NO. 3000 SIGNATURE: CERTIFICATION EXPIRATION DATE: March 31, 2013 P.O. Box 86 • Issaquah, Washington 98027 • (425) 313 -0172 • Fax (425) 313 -5735 40.cooftrortmentai Nil lIkartifiratiott THIS IS TO CERTIFY THAT AIRTEST Coloparty, Inc. in Issaquah, WA HAS MET ALL REQUIREMENTS FOR RENEWAL OF NEBB CERTIFICATION IN ME FOLLOWING DISCIPLINE jiiiyAontcs Systems & d S Exp. _march. 31, 2013 .AIRTEST. Company, Inc./WA WO. 3000 NEBB Cert. No. 4:4? FOR THE BOARD OF DIRECTORS: President President-Elect 07eAoirnnnienttt[ 11kikt17 gig lattertification THIS IS TO CERTIFY THAT Brent X. man �vit .AIRDEST Comyany, Inc. it Issaquah, -W HAS lT ALL THE NEBB REQUIREMENTS FOR NEBB CTF PROFESSIONAL STATUS IN & Nyd/OliCS Systems Exp. 941arch 31, 20I3 iiIR:TEST`Company, Inc./W5 No. 3000 NEBB Cert. No. POR THE BOARD dE )IRECTORS: President President -Elect AiRTEST Co., Inc. Warranty of TAB Services PROJECT: Westfield Southcenter — Apple Store Suite #801 LOCATION: Tukwila, WA PROJECT #: 11- 3031 -1 DATE: 9/13/2011 TECHNICIAN: Mike Touchette Warranty of TAB Services: AIRTEST Co., Inc. warranties the TAB work performed on this project for one year from the date of the first published report. AIRTEST Co., Inc. reserves the right to correct errors or omissions in the collection of data, and issue amended TAB reports. This Warranty covers all Test and Balance services provided by AIRTEST unless otherwise stated in writing. When any balancing issues or concerns arise, AIRTEST Co., Inc. will dedicate resources to understand the issue or question. This may include a return trip(s) to the project site, or other appropriate methods of resolving the issue. A return trip(s) to the site, if necessary, will involve verification of system adjustments and adherence to reported values. No charges will be issued for any work found to be in compliance with the reported data, however if AIRTEST Co., Inc. is directed to make adjustments that result in differences from the reported data (i.e. Comfort Balancing), charges may be incurred. Repeated requests for Warranty services may incur charges if the TAB work is found to be in compliance with the reported data. Voided Warranty and Additional Charges: When issues arise due to mechanical equipment failure, control or maintenance related causes, the return trip may be subject to a service charge not covered under warranty. AIRTEST Co., Inc. reserves the right to resolve any TAB issues. Actions by others to resolve a warranty issue before AIRTEST Co., Inc. is notified, or allowed sufficient time to respond, will result in a voided project warranty. Any return trip(s) to the jobsite as a result of such actions are subject to charges. A purchase order will be required before returning to the jobsite if such conditions exist. Document Archiving: An electronic copy of the test data will be provided at no charge for the warranty period. Electronic copies of the project test data may be available after the warranty period, at no charge. Printed / bound copies will be subject to a fee. P.O. Box 86 • Issaquah, Washington 98027 • (425) 313 -0172 • Fax (425) 313 -5735 AIRTEST Co., Inc. Calibration Report PROJECT: Westfield Southcenter - Apple Store Suite #801 LOCATION: Tukwila, WA PROJECT #: 11- 3031 -1 DATE: 9/13/2011 TECHNICIAN: Mike Touchette 4 F'4E[r . -''+ ,' \INSRUMNISERIALNUMBER Y r-1ws.•' N APPLICATION DATsEO II,PE -, CALIBRATIOi N 3: n TSADATE, PACER DA400 / 1014147 Velocity Sep -11 11/10 Alnor Balometer 6463 / 70634301 CFM Sep -11 1/11 Alnor EBT -720 / 90634003 Pressure Sep -11 1/11 SHIMPO DT207L -S12 / D081B0002 RPM Sep -11 4/11 VOM, Fluke T5-600 / 96202405 Electrical Sep -11 4/11 Alnor Micro M / 90524090 Temperature Sep -11 8/11 Alnor HM670 / 70633311 Hydronics Sep -11 8/11 SYM BOLS;B.ABBREYIATION S ADJ = Adjustable Fan Speed CD = Ceiling Diffuser CFM = Cubic Feet per Minute D/A = VAV Inlet Dimension in Inches DD = Design Data EG = Exhaust Grille E.S.P. = External Static Pressure FIC = VAV Calibration Factor FCD = Field Collected Data FG = Floor Grille FLA = Motor Full Load Amps GPM = Gallons per Minute HP = Horsepower Hz = Hertz in. Hg. = Inches Mercury in. w.g. = Inches Water Gauge LD = Linear Diffuser LD x = Linear Diffuser where "x" is number of slots N/A = Not Available NI = Not Installed NR = Not Required NPSH = Net Positive Suction Head RG = Retum Grille RPM = Revolutions per Minute SF = Motor Service Factor S.P. = Static Pressure SWG = Side Wall Grille T.S.P. = Total Static Pressure VAR = Variable Fan Speed AIRTES1 'Co., I, Heat Pump PROJECT: Westfield Southcenter - Apple Store Suite #801 LOCATION: Tukwila, WA PROJECT #: 11- 3031 -1 DATE: 9/13/2011 CONTACT: Mike Touchette SYSTEM/UNIT: HP -3 AREA: Apple Store #501 ' � #x Un teData ^^ Unit Location Roof Unit Manufacturer Trane Unit Model Number WSC120 Unit Serial Number 837100102L Unit Serves Apple Store HP -3 / Fan Fan Type / Class FC /1 POP44r Test Da tag SP Inlet Actual -.20 in. wc. SP Outlet Actual .66 in. wc. External SP Actual .86 in. wc. HP -3 / Fan Fan RPM Actual 980 RPM tfAr Data Tot. GRD CFM Des. 3900 CFM Tot. GRD CFM Act. 3680 CFM Elec�'tricalkTestwData HP -3 /Fan Motor Volts 1 480 Volts Motor Volts 2 479 Volts Motor Volts 3 478 Volts Motor Amps 1 3.0 Amps Motor Amps 2 2.9 Amps Motor Amps 3 2.9 Amps Tested By: Mike Touchette Test Date: September 09, 2011 - ' Motowata ^,, - HP -3 / Fan Motor Manufacturer G.E. Motor HP 2.0 HP Motor RPM 1025 RPM Motor Frame 145T Motor Rated Volts 460 Volts Motor Phase 3 Motor Hertz 60 Hz Motor FL Amps 2.9 Amps Motor Service Factor 1.15 Sheave Data ,4.. HP -3 / Fan Drive Type Belt Belt Size A35 Number of Belts 1 Motor Sheave 1VL40 @ max Motor Sheave Bore 7/8 in. Fan Sheave AK64 Fan Sheave Bore 1 in. Sheave Center Line 11 in. tfAr Data Tot. GRD CFM Des. 3900 CFM Tot. GRD CFM Act. 3680 CFM Filter ta HP-3 / Filter Filter Manufacturer Flanders Filter Type Pleated Filter Quantity 4 Filter Size 20x25x2 Airiest Co Inc ,AIRTES1 to., Inc. Heat Pump PROJECT: Westfield Southcenter - Apple Store Suite #801 LOCATION: Tukwila, WA PROJECT #: 11- 3031 -1 DATE: 9/13/2011 CONTACT: Mike Touchette SYSTEM /UNIT: HP -3 (Cont.) AREA: Apple Store #501 HP -3 Supply Outlet Summary Tested By: Mike Touchette Test Date: September 09, 2011 Sy_ tem /iUn t •` - `•`�AreaServed '� _. �".... i 'f'� " '�r. @, Outlets r Type � tiSize'"LxW I? Design ti CFM, �y °Prelim aeadmg: u4,sR.5:u4Tau..��. F nal Readmg [2* .+a %F al Deviation; `��"r�'as. ZD -1 -1 Hall CD 6 RD 100 50 85 85 ZD -1 -2 * Restroom CD 6 RD 75 50 85 113 ZD -1 -3 * Restroom CD 6 RD 75 55 80 107 ZD -1-4 Hall CD 6 RD 100 55 80 80 ZD -2 -5 Break Room RD 12 RD 550 180 500 91 ZD -2-6 Break Room RD 12 RD 550 170 510 93 ZD -2 -7 Break Room RD 12 RD 550 250 510 93 ZD -3-8 Office CD 8 RD 150 180 150 100 ZD -4 -09 Stock Room SWD 10 x 8 250 450 230 92 ZD -4-10 Stock Room SWD 10 x 8 250 420 230 92 ZD -4 -11 Stock Room SWD 10 x 8 250 330 225 90 ZD -5 -12 Manager Office CD 16 RD 400 700 385 96 ZD -6 -13 Genius Room CD 12 RD 200 300 180 90 ZD -6 -14 Genius Room CD 12 RD 200 320 220 110 ZD -6 -15 Genius Room CD 12 RD 200 340 210 105 Totals fi? -. 3;900`« Y 'W °+� a MiltgAi * Notes HP -3 HP -3 HP -3 / ZD -1 -2 HP -3 / ZD -1 -3 8- Sep -11 Mike Touchette 8- Sep -11 Mike Touchette 8- Sep -11 Mike Touchette 8- Sep -11 Mike Touchette Bypass Damper Setting: .60" w.c. Zone Damper Settings: ZD -1= 100 %, ZD -2 =100 %, ZD- 3 =60 %, ZD- 4=40 %, ZD- 5=45 %, ZD -6 =75% No volume damper. No volume damper. Airtest Co Inc �ERN!!T COORD COPIO PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M11 -106 PROJECT NAME: APPLE STORE SITE ADDRESS: 801 SOUTHCENTER MALL DATE: 07/29/11 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPART ENTS: 6 ilding Division Public Works 51 14 6ttlytnA■ ire Prevention Structural Planning Division ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete DUE DATE: 08/02/11 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 08/30/11 Approved Approved with Conditions Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 Contractors or Tradespeople Peter Friendly Page • General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name PACIFIC AIR CONTROL INC UBI No. 601298907 Phone 2066826393 Status Active Address 11812 N Creek Pkwy N License No. PACIFAC230P8 104 Suite /Apt. License Type Construction Contractor City Bothell Effective Date 10/28/1977 State WA Expiration 10/1/2011 Date Zip 98011 Suspend Date County King Specialty 1 Business Type Corporation Specialty 2 Parent Company Heating /Vent /Air - Conditioning And Refrig (Hvac /R) Unused Business Owner Information Name Role Effective Date Expiration Date CRAWFORD, LARRY C Cancel Date 01/01/1980 Bond Amount RUTTAN, GARY J 9 01/01/1980 104920215 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 9 TRAVELERS CAS & SURETY 104920215 05/26/2007 Until Cancelled $6,000.00 05/09/2007 8 MERCHANTS BONDING CO (MUTUAL) WA14019 05/26/2005 Until Cancelled 05/26/2007 $6,000.00 05/25/2005 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 19 PHOENIX INSURANCE COMPANY THE 4TC07314N491 PHX09 07/01/2010 07/01/2012 $1,000,000.00 05/03/2011 18 PHOENIX INSURANCE COMPANY 4TC07314N491PHX09 07/01/2009 07/01/2010 $1,000,000.00 07/02/2009 17 NATIONWIDE MUTUAL INS CO ACP7501585754 07/01/2009 07/01/2010 $1,000,000.0006 /17/2009 16 NATIONWIDE MUTUAL INS CO ACP7501585754 07/01/2004 07/01/2009 $1,000,000.0005 /27/2008 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https://fortress.wa.gov/lni/bbip/Print.aspx 08/24/2011 SOWSKOMMTPMAM STORE B24 APPLE, INC. K62 Kti n' a V40 x r x:o i z cr IAM SUPPLY RETURN "WI ■Ifi ACKDRAFT DAMPER 1165A .. EITHER LOCATION UPSTREAM OF BP BEFORE FIRST RETURN TAKEOFF � Z BYPASS DAMPER (PER SCHEDULE) ELEVATION VIEW SUPPLY RETURN 11111 ralrAllff \--BYPASS DAMPER PLAN VIEW BYPASS DETAIL Xn0 ZD SUPPLY TAKEOFF (WRAPPED) X "0 ZONE DAMPER TITUS CDR W /RELIABLE DDC CONTROLS OR EQUIV. SIZE PER SCHEDULE 1.5 DIAM- ZONE DAMPER DETAIL LEGAL DESCRIPTION: WEA SOUTHCENTER LLC BSIP PER BSIP REC VOL 256 PGS 1 -9 WHICH REPLACES BSIP REC VOL 249 PGS 77 -84 (AKA PARCEL A TUKWILA BSIP #L10 -032 REC #20101021000765) TAX PARCEL NUMBER: 920247 -0010 WESTFIELD SOUTHCENTER MALL VICINITY MAP NTS DESCRIPTION OF WORK: MODIFICATION TO EXISTING HP -3 (APPLE STORE) DUCTWORK TO INCLUDE INSTALLATION OF 6 ZONE DAMPER (2 ARE EXISTING) SYSTEM AND BY -PASS, WITH UPGRADED RELIABLE(R) DDC CONTROLS. NO NEW HEATING /COOLING EQUIPMENT ARE SCHEDULED FOR THIS IMPROVEMENT. VVT SCHEDULE FOR HP -3 TAG AREA SERVED SIZE MIN CFM MAX CFM BASIS OF DESIGN HP -3 APPLE STORE 10 -TON 0 3900 EXISTING ROOFTOP UNIT ZD -1 R/R & HALL 6 "0 50 350 TITUS CDR OR EQUIV. ZD -2 BREAK ROOM 16X14 50 1650 TITUS CDR OR EQUIV. ZD -3 OFFICE CO 25 150 TITUS CDR OR EQUIV. ZD -4 STOCK ROOM 12X12 50 750 TITUS CDR OR EQUIV. ZD -5 MGR OFFICE 18X6(E) 50 400 TITUS CDR OR EQUIV. ZD -6 GENIUS ROOM 18X6(E) 50 600 TITUS CDR OR EQUIV. BP -1 BYPASS 14 "0 0 2000 TITUS CDR OR EQUIV. NOTES: 1) DUCT SIZE TO BE ONE SIZE LARGER THAN ZONE DAMPER (EVEN SIZES) 2) VERIFY LOCATION OF ZONE SENSORS AND CENTRAL CONTROLLER WITH G.C. 3) DOC CONTROLS TO BE RELIABLE CONTROLS. 4) POWER WIRING BY OTHERS L REVISIONS No rhenaes shall be made to the scope cf work without prior approval of ukwila Building Division. NC"'- s':tions will require a new plan submittal L - ., mxy in :Aide additional plan review fees. 1 PRA RATE PERMIT REQUIRED FOR: ❑ Mechanical Leiectrical ftumbirt0 was Piping of Tukwila ;G DIVISION SYMBOL ABBREV. IZ sl I�l 1 I T 7 z 7 �•s--- WT -i' LEGEND & ABBREVIATIONS DESCRIPTION SUPPLY DUCT RETURN /EXHAUST DUCT SL SOUNDLINED DUCT VD MANUAL VOLUME DAMPER FC FLEX CONNECTOR TV TURNING VANES EC END CAP T, SD SUPPLY DIFFUSER, CEILING MG MAKEUP GRILLE RG RETURN GRILLE, CEILING EG EXHAUST GRILLE, CEILING TG TRANSFER GRILLE, CEILING SIDEWALL SUPPLY /MAKEUP SIDEWALL RETURN /EXHAUST EQUIPMENT TAG AFF ABOVE FINISHED FLOOR BD, BDD BACKDRAFT DAMPER BS BIRDSCREEN DN DOWN EA EXHAUST AIR OA, OSA OUTSIDE AIR- RA RETURN AIR SA SUPPLY AIR (N) NEW (E) /EXIST EXISTING (R) RELOCATED BWG BOTTOM WALL GRILLE TWG TOP WALL GRILLE TYP TYPICAL VD VOLUME DAMPER SYMBOL ABBREV. DESCRIPTION • Tu --0 FIRE DAMPERED DUCT PENETRATION OF A HORIZONTAL SEPARATION FIRE DAMPERED DUCT PENETRATION OF A VERTICAL SEPARATION TIMER 0 -4 HR ADJUSTIBLE THERMOSTAT /HVAC UNIT # SENSOR /HVAC UNIT # EXHAUST FAN — PIPE /DUCT UP PIPE /DUCT DOWN PIPE TEE DOWN PIPE TEE UP EXIST DUCTWORK, EQUIP NEW DUCTWORK, EQUIP ADJ ADJACENT BSC BIOLOGICAL SAFETY CABINET CFH CHEMICAL FUME HOOD CFM CUBIC FEET PER MINUTE DB DUCT BOARD L,S LIQUID, SUCTION N NECK NIC NOT IN CONTRACT OAI OUTSIDE AIR INTAKE RD ROUND DIFFUSER SHC SENSIBLE HEATING CAPACITY SR SUPPLY REGISTER TC TOTAL COOLING VEL VELOCITY WH WATER HEATER 0 - ---- -- DEMO AIR TERMINAL LEGEND XX 8x8 NECK SIZE (INCHES) SQUARE OR RECTANGULAR GRILLE, REGISTER, DIFFUSER IN LEGEND 1 40 AIR QUANTITY (CFM) XX 8 "0 NECK SIZE (INCHES) 140 ROUND Air Quantity (CFM) ARROWS INDICATE AIR PATTERN FOR CEILING DIFFUSERS NO ARROWS INDICATE FOUR WAY PATTERN REVIEWED FOR CODE COMPLIANCE APPROVED AUG 1 2011 A-S City of Tuktviia BUILDING DIVISION FILE COPY Pecmlt No. Plan review approval is subject to errors and omissions. k:r cvat of construction documents does not authorize t } v ol€ tion of any adopted code or ordinance. Receipt aPProv- l Reid Copy and ' 'fir = is acknowledged: By vIPLLOLtyLk City Of lbkwlla BUILDING DIVISION CITYVVSLA JUL 2 9 2011 PERMIT CENTER DRAWING INDEX M -1 COVER SHEET, LEGEND, SITE PLAN, DETAILS M -2 HVAC DEMO PLAN, HVAC REVISED PLAN M I V 00 Air Conditioning Heating Controls Sales Service Installation "QUALITY ASSURED pacific air control, inc. 11812 Northcreek Parkway N., Suite 104 Bothell, WA 98011 ph: (206) 682 -6393 fax: (206) 340 -2270 Contractor's License No.: PACIFAC230P8 www. pacificaircontrol.com APPLE STORE N ^U DATE 7/27/11 DESCRIPTION PM REVIEW A 7/28/11 PERMIT ISSUE A 0 A A THIS DRAWING IS THE SOLE PROPERTY OF PACIFIC AIR CONTROL INC. ANY REPRODUCTION, DUPLICATION, ADDITIONS AND /OR MODIFICATIONS REQUIRE THE WRITTEN APPROVAL OF PACIFIC AIR CONTROL, INC. PROJECT MANAGER DS DESIGNED BY DL /DS DRAWN BY DL CHECKED BY DS SCALE AS NOTED PROJECT NO. Ti 10708 DRAWING 717LES COVER SHEET EQUIPMENT SCHEDULE DETAILS FILEPATH: U: \ACAD \PROJECTS \CANYON PARK J \SUITE 101 SHEET NUMBER M -1 of 2 PACIFIC AIR CONTROL, INC. 2010 /I f r L ; EXISTING DUCTVORK DEMO 11 tti - ' ___._. dye,•, %%I IntraiirillEiditiMiiiillikir 'EXISTING rEX Ft E { REII A. OVE REGISTERS D CAP DJCT I_. FLOOR PERMIT) { EXISTING DJCT REIWIOVE YOUNG REGULATORS . ; RtU 'E -DAMT ER APPLE STORE j SUITE #B24 - EXISTING /DEMO HVAC PLAN SCALE: 1/4" = 1' - 0" ids 14X6(E) 250 CFM (TYP.3) "0 CD 100 CFM EXISTING x-1.1 -W 16X 6- L TRANSFER 1 l � 6 "0 CC 100 CFA r II 24X2 ( RA I�IEW- ._. ✓DO OFFICE { 8- _44rG...If ..... ......... ``CFM' " 6� ..C13 I 75 (1 ZD -4 12X1.2, DAMPER I • ZONE 6 "0 ZONE DAMPER 'EXISTING RESTROOM r r GENERAL NOTES: 1. ALL SIZES SHOWN ARE INSIDE CLEAR, UNO. 2. ALL HVAC UNITS ARE EXISTING. 3. REPLACE YOUNG REGULATOR CONTROLS WITH ELIABLE(R) DDC CONTROLS. 4. INSTALL MAIN CONTROLLER IN MANAGER'S OFF CE (VERIFY WITH TENANT). 5. CLEAN ALL DIFFUSERS AND GRILLES, REPAIR I NECESSARY. 6. AIR BALANCE PER INDICATED AIRFLOWS. PROVIDE WRITTEN REPORT WITH CLOSE —OUT DOCS. r .W :RI ANSFER ZON E 1# DA(VIPE TITUS TIM RD DIFFUSERS MIN. 9' -0" AFF (TYP.) 12 "0 RD 550 CFM (TYP.3) ZD- 12"0 CD 200 CFM (Typ:3)- — N WITH 16 "0 CD 400 CFM W ACTUATORS t-LDDC- REUAB MOR OFFICE GENIUS ROOM L. APPLE STORE SUITE #B24 - REVISED HVAC PLAN SCALE: 1/4" = 1' - 0" :f ..1 RETAIL (NO WO t ; City of Tukwila BUILDING DIVISION 1FILEPATH: U: \ACAD \PROJECTS \WESTFIELD SOUTHCENTER \APPLE cmiiRIu+ JUL 2 y 2011 PERMIT CENTER Air Conditioning Heating Controls Sales Service Installation "QUALITY ASSURED" pacific air control, inc. 11812 Northcreek Parkway N., Suite 104 Bothell, WA 98011 ph: (206) 682 -6393 fax: (206) 340 -2270 Contractor's License No.: PACIFAC230P8 A A www.pacificaircontrol.com DATE 7/27/11 7/28/11 DESCRIPTION PM REVIEW PERMIT ISSUE A n A THIS DRAWING IS THE SOLE PROPERTY OF PACIFIC AIR CONTROL, INC. ANY REPRODUCTION, DUPLICATION, ADDITIONS AND /OR MODIFICATIONS REQUIRE THE WRITTEN APPROVAL OF PACIFIC AIR CONTROL INC. PROJECT MANAGER DS DRAWN BY DL SCALE AS NOTED DESIGNED BY DL /DS CHECKED BY DS PROJECT NO. Ti 10708 DRAWN° 1171E5 HVAC DEMO PLAN REVISED HVAC PLAN SHEET NUMBER M -2 of 2 PACIFIC AIR CONTROL, INC. 2010