Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M11-107 - WESTFIELD SOUTHCENTER MALL - JIMMY JOHN'S
JIMMY JOHN'S 728 SOTJTHCENTER MALL Mi 1 -107 City oikukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206- 431 -2451 Web site: http: / /www.TukwilaWA.gov MECHANICAL PERMIT Parcel No.: 9202470010 Address: 728 SOUTHCENTER MALL TUKW Project Name: JIMMY JOHN'S Permit Number: M11 -107 Issue Date: 08/22/2011 Permit Expires On: 02/18/2012 Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA 92013 Contact Person: Name: MITCH HART Address: 234 5 AV S , EDMONDS WA 98020 Email: Contractor: Name: WILCOX CONSTRUCTION INC Address: 123 4TH AVE N , EDMONDS, WA 98020 Contractor License No: WILCOC* 194Q0 Phone: 425 - 774 -4185 Phone: 425 774 -4185 Expiration Date: 12/10/2011 DESCRIPTION OF WORK: REUSE EXISTING FAN POWERED VAV BOX. NEW MECHANICAL DUCTWORK. Value of Mechanical: $15,000.00 Type of Fire Protection: UNKNOWN Electrical Service Provided by: Permit Center Authorized Signature: I hereby certify that I have read an governing this work will be compli ex wit Fees Collected: $367.31 International Mechanical Code Edition: 2009 Date: ed this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. The granting of this permit does not p1 . ne to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this permit. Signature: Print Name: Date: Ula2 /1 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -4/10 M11-107 Printed: 08 -22 -2011 PERMIT CONDITIONS Permit No. M11-107 1: ***BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tulcwila Building Department (206- 431- 3670). 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tulcwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IMC -4/10 M11-107 Printed: 08 -22 -2011 CITY OF TUKLA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us • Building Permit No. t ( - d-wf v Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No. Project No. til-107 Gil- ll5 (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION King Co Assessor's Tax No.: Site Address: 728 Southcenter Mall Suite Number: 14480 Floor: 1 Tenant Name: Jimmy John's Property Owners Name: Sandwich LLC Mailing Address: 111 E. Jefferson Ave. Suite 1N v New Tenant: m Yes ❑..No Naperville, IL City State 60540 Zip CONTACT PERSON - who do we contact when your permit is ready to be issued Name: Mitch Hart - Wilcox Construction Mailing Address: 234 5th Ave. S. E -Mail Address: mhart@wilcoxconstruction.com Day Telephone: (425) 774 -4185 Edmonds, WA City State Fax Number: (425) 774 4187 98020 Zip GENERAL CONTRACTOR INFORMATION -. .:(Contractor Information for Mechanical (pg 4);for Plumbing and Gas Piping (pg 5)) Company Name: Wilcox Construction Mailing Address: 234 5th Ave. S. Contact Person: Mitch Hart E -Mail Address: mhart@wilcoxconstruction.com Contractor Registration Number: Edmonds, WA City State Day Telephone: (425) 774 -4185 Fax Number: (425) 774 -4187 98020 Zip Expiration Date: •ARCHITECT OF RECORD - All:plans'must be-stainped by Architect of Record- . Company Name: Chipman Design Architecture, Inc. Mailing Address: 1550 N. Northwest Highway, Suite 400 Contact Person: Dana Rizzo E -Mail Address: drizzo @chipmandesignarch.com Park Ridge, IL City State Day Telephone: (847) 298 -6900 Fax Number: (847) 298 -6966 60068 Zip ENGINEER OF RECORD - All plans,must be:stamped by Engineer of Record Company Name: Abossein Engineering, LLC Mailing Address: 2100 112th Ave. NE Suite 102 Contact Person: Gary Womack E -Mail Address: gary_womack @abossein.com H :Wpplications\Forms- Applications On Line V2010 Applications17 -2010 - Permit Application.doc Revised: 7.2010 bh Bellevue, WA 98004 City State Zip Day Telephone: (425) 462-9441 Fax Number: Page 1 of 6 MECHANICAL PERMIT INFORM•ON — 206 - 431 -3670 • MECHANICAL CONTRACTOR INFORMATION Company Name: T.B.D. Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Mechanical work (contractor's bid price): $ 15,000 Scope of Work (please provide detailed information): Reuse existing fan powered VAV box. Ne mechanical ductwork. Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New .... Replacement .... ❑ Fuel Type: Electric ❑ Gas....m Other: Indicate type of mechanical work being installed and the quantity below: Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace <100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace >100K BTU Evaporator Cooler Diffuser 10 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System 1 Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct 1 Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig /Cooling System Incinerator - Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM Incinerator — Comm/Ind H \Apphcanons\ Forms - Applications On Line\2010 Applicanons \7 -2010 - Permit ApplIcation.doc Revised 7 -2010 bh Page 4 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUT IORIZED AGENT: Signature: Print Name: Mailing Address: /f /E. <FiCie r4 ,i JUTE - /Ai =ate: 7A7 I Day Telephone: q-- c.).Sf-S City State Zip --I IDate Application Accepted: Date Application Expires: I �_ I Staf Initials: Gk/C 1 ,)-01_ 1 11:1App1icnhions\l'omu- Applice.timu On 1.inc\2010 Applkm ions \7.2010 - I' nnit Applicedion.doo Revised: 7.2010 bh Page 6 of 6 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov RECEIPT Parcel No.: 9202470010 Permit Number: M11 -107 Address: 728 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 07/29/2011 Applicant: JIMMY JOHN'S Issue Date: Receipt No.: R11 -01820 Payment Amount: $293.85 Initials: JEM Payment Date: 08/22/2011 11:02 AM User ID: 1165 Balance: $0.00 Payee: ANDREW J SHARPE TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 00527C ACCOUNT ITEM LIST: Description 293.85 Account Code Current Pmts MECHANICAL - NONRES 000.322.102.00.00 293.85 Total: $293.85 doc: Receiot -06 Printed: 08 -22 -2011 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: / /www.TukwilaWA.gov RECEIPT Parcel No.: 9202470010 Permit Number: M11 -107 Address: 728 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 07/29/2011 Applicant: JIMMY JOHN'S Issue Date: Receipt No.: R11 -01622 Payment Amount: $73.46 Initials: WER Payment Date: 07/29/2011 02:46 PM User ID: 1655 Balance: $293.85 Payee: CHIPMAN DESIGN ARCHITECTURE TRANSACTION LIST: Type Method Descriptio Amount Payment Check 22552 73.46 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 73.46 Total: $73.46 doc: Receiot -06 Printed: 07 -29 -2011 4411-/eA INSPECTION RECORD Retain a copy with permit . INSPECTION NO. PERMIT NO. • CITY OF TUKWILA BUILDING DIVISION .. 6300 Southcenter Blvd., #100, Tukwila. WA 98188 p- (206) 431 -36 Permit Inspection Request Line (206) 431 -2451 Project: t : �'7 a1 // ;3�'l h C Type of Inspection: ,/ /�/ hG!' Address:. 1 A G �-ht D to Called: /% specia Instructions: . • • Date Wante • 7 -6 -12 - aim. O Requester: Phone No: pApproved per applicable codes. °Corrections required prior to approval. COMMENTS: , REI SPECTION FEE RE/UIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. • INSPECTION RECORD Retainia copy with permit INSPECTION NO. PERMIT NO. CITY OF' TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 /tf / / -low Proje - .• 3;4.43 Type of Inspection: t-4 /0 "`e Addre s:.Z. / / / ,� �� Date Called: Special Instructions: • �;�4 /� Date Wanted: . -.+ Requester: Phone No: Approved per applicable codes. ACorrections required prior to approval. j COMMENTS: e • REINPECTION FEE RE IRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -367 Permit Inspection Request Line (206) 431 -2451 INSPECTION RECORD Retain a copy with permit PERMIT NO. Project: i gr-11 h^n"-1 (4011 6 Type of Inspection: I'IN) pll. Address: 7zri c...,c) Q H 1M At 1 Date Called: Special Instructions: Date Wanted:. i1 -1—t1 p.m. Requester: Phone No: „206, -et7 -72711 L1Approved per applicable codes. D Corrections required prior to approval. COMMENTS: p,4 iN) 0 70 7- S..f4,2 /LA tc.4,,,--,arr 496-47-' 1-) o 7 ®s- P-C-eitgel$-0 Ai F��/ /5- 3) C o /t o / C 0 rer -7,1-1 6047/ 15 5 4-e Inspector: nIDate: //1 f . n REINSPECTION FEE RE UIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100: Call to schedule reinspection. c1r INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 /77/ /-- /t 7 Project: .►�. , i.ri, O AA, C Type of Inspection: - /) q ,9 j — . .i �; Ad al 7.2 $ rn' // Date Called: Special Instructions: Date Wanted:. 9- JO -- /l p.m. Requester: Phone No: c9 ,0 4 -8/7'727 R - Sj Approved per applicable codes. Corrections required prior to approval. COMMENTS: 1 PECTION FEE REQUIRED. rior toAext inspection. fee must be ai at 6300 Southcenter Blvd.. S ite 100. Call to schedule reinspection. INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit /-I F 0Z-// PERMIT NUMBERS CITY OF TU'KWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206 -575- Project: Type of Inspection: v Address: Suite #: 72S. - 1,,rt1,an-k2. "Lick. (I Contact Person: r r c., rckrv,e.Pz. Special Instructions: Phone No.: proved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: -f ii4c� y - ta4e . // wit- Sh L-/- c/o, .rA! O/<. fitubV/A4 k L-fr2.,) be.-- cg, 5P... / k_t e ,c_ i.�'e2 Oi< Mre..- ,5%.7, 4 1 . Occupancy Type: mll_a 6, .: 4- Needs Shift Inspection: Sprinklers: Fire Alarm: -f ii4c� y - ta4e . Hood & Duct: k Monitor: Pre -Fire: Permits: Occupancy Type: Date: h/ /, rs.. ?30 $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Word /Inspection Record Form.Doc 6/11/10 Zip: T.F.D. Form F.P. 113 Prrn 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Ailichanical Summary MECH -SUM 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised August 2010 Project FEL ��ii,, Info " _ COPY Project Address Jimmy Johns Date 7/27/20111 Sourthcenter Mall-Suite 1480 For Building Dept. Use Tukwila, WA Applicant Name: Applicant Address: Applicant Phone: Project Description Briefly describe mechanical system type and features. ❑ Includes Plans I Ductwork and air distribution from existing VAV Box Include documentation requiring compliance with commissioning requirements, Section 1416. Compliance Option 0 Simple System 0 Complex System 0 Systems Analysis (See Decision Flowchart (over) for qualifications. Use separate MECH -SUM for simple & complex Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. Cooling Equipment Schedule Equip. ID Equip Type Brand Name' Model No.' Capacity2 Btu/h OSA CFM or Econo? SEER or EER IPLV3 Econmizer Option or Exceptions Heat Recovery Y/N See 1401 Heating Equipment Schedule Equip. ID Equip Type Brand Name' Model No.' Capacity2 Btu/h OSA cfm or Econo? Input Btuh Output Btuh Efficiency4 Heat Recovery Y/N See 1401 o Fan Equipment Schedule Equip. ID Equip Type Brand Name' Model No.' CFM SP' HP /BHP Flow Controls Location of Service See 1,101 FOR REVIEWED COMPLIANCE - CODE APPROVED • AUG 19 2011 '1 available. 2 As tested according 5 low control types: variable air volu City of Tukwila BUILDING DIVISION' o Table 14-1A through 14-1G. 3 If required. ° COP, HSPF, Combustion Efficiency, or AFUE, as applicable. e(VAV), constant volume (CV), or variable speed (VS). 6 Exception number from Section 1433. RECEIVED JUL 29 2011 PFRMITCFMTm WIOTJ 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential • Mechanical Permit Plans Checklist M Code Compliance Forms for Nonresidential and Multifamily Residential €CH - I CHK 2 J09 Washington State Energy Revised August 2010 Project Address Jimmy. Johns 'Date 7/27/2011 The following _information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Applicability (yes, no, na) I Code Section Component 'Information Required aLocation on Plans I Building Department Notes HVAC REQUIREMENTS (Sections 1401 -1424) 1411 Equipment Performance -- • •-• • - ----- N.A. 1411.1 Minimum efficiency Equipment schedule with type, capacity, efficiency N.A. 1411.1 Combustion htg. Indicate intermittent ignition, flue /draft damper & jacket Toss N.A. 1411.1 Air - cooled chiller Provide total air and water chiller capacity N.A. 1411.2.1 Water - cooled chiller Full -load and NPLV values adjusted for any non - standard condiitons N.A. 1411.4 Pkg. elec. htg.& clg. List heat pumps on schedule N.A. 1411.5 Unenclosed Heat Indicate radiant heat system and occupancy controls 1412 HVAC Controls Yes 1412.1 Temperature zones Indicate locations on plans Mot Yes 1412.2 Deadband control Indicate 5 degree deadband minimum Mot N.A. 1412.3 Humidity control Indicate humidistat N.A. 1412.4 Setback and Shutoff Indicate thermostat with 7 day program capability & required setback Yes 1412.4.1 Dampers Indicate damper location, leakage rate, control type, & max. leakage Moa N.A. 1412.4.2 Optimum Start Indicate optimum start controls N.A. 1412.5 Heat pump control Indicate heat pump thermostant & outdoor lockout on schedule N.A. 1412.6 Combustion heating Indicate modulating or staged control . Yes 1412.7 Balancing Indicate balancing features on plans Moa N.A. 1412.8 Ventilation Control Indicate demand control ventilation for high- occupancy areas N.A. 1412.9 Loading Dock & Garage Ventilation Indicate enclosed loading dock & parking garage ventilation system activation and control method. N.A. 1422 Thermostat interlock Indicate thermostat interlock on plans N.A. 1432.2.1 Temperature Reset Indicate temperature reset method 1413 Air / Water Economizers N.A. 1412.1 Single zone systems Indicate multiple cooling stage control capability. N.A. 1413.1 Air Econo Operation Indicate 100% capability on schedule N.A. 1413.1 Wtr Econo Operation Indicate 100% capacity at 45 degF db & 40 deg F wb N.A. 1413.2 Wtr Econo Document Indicate max. OSA condition for design clg load & equipment performance data. N.A. 1413.3 Integrated operation Indicate capability for partial cooling N.A. 1413.4 Humidification Indicate direct evap or fog atomization w/ air economizer 1414 Ducting Systems Yes 1414.1 Duct sealing Indicate duct design pressures and sealing requirements Mot Yes 1414.1 Duct testing Indicate testing required Mot Yea 1414.2 Duct insulation Indicate R -value of insulation on duct Mo1 1415 Piping Systems _ .. ., Yes 1415.1 Piping insulation 'Indicate R -value of insulation on piping , ='POT , : _1 •J: ,. ,: • 1.1 Completion Requirements -: - )(f,' J.• -i`f, •1416 ; y -j( ;,•, - Yes 1416.3.2 System Balancing Indicate air and water system balancing requirements i m014V (.. r`i- ;,: Yee 1416.3.3 Functional Testing Provide sequence of operations and test procedures. i 1401 , Yes 1416.3.4 Documentation Indicate O &M manuals, record drawings, staff training ; 1401 Yea 1416.3.5 Comm. Report Indicate requirements for final commissioning report �t M01 i Yes 1416.4 Compliance Chklist Submit to building official upon substantial completion. Mo1 t : P , -, Yes Mechanical Summary Form Completedpdi tttach ed. Equipment s1hedtile wit Rtypes input/outptOD efficiency,cfm, hp, economizer •• -- _- .I,:.. •) i t j i.. 1 :'ti t..j r • j i :1 cl . _ _ - .I_.. -.- . . _ X. 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Mechanical Permit Plans Checklist Continued MECH -CHK 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised August 2010 Project Address Jimmy Johns (Date 7/27/2011 The following information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Applicability (yes, no na) Code I Section Component Information Required Location on Plans Building Department Notes SERVICE WATER HEATING AND HEATED POOLS (Sections 1440 -1454) 1440 Service water htg. N.A. 1441 Elec. water heater Indicate R -10 insulation under tank N.A. 1442 Shut -off controls Indicate automatic shut -off of circulators or heat trace N.A. 1443 Pipe Insulation Indicate R -value of insulation on piping N.A. 1444 Pump Energy Indicate method of pump energy management (Sec 1438) N.A. 1445 Heat Recovery Indicate preheat capacity as % of peak service water demand. N.A. 1452 Heat Pump COP Indicate minimum COP of 4.0 N.A. 1452 Heater Efficiency Indicate pool heater efficiency N.A. 1453 Pool heater controls Indicate switch and 65 degree control N.A. 1454 Pool covers Indicate vapor retardant cover N.A. 1454 Pools 90+ degrees Indicate R -12 pool cover N.A. 1455 Heat Recovery Indicate method and capacity of exhaust air temperature reduction 1460 Cold Storage N.A. 1463 Evaporators Indicate motor type and speed control N.A. 1464 Condensors Indicate condenser cooling type, design wb temp and control N.A. 1465 Compressors Indicate design minimum condensing temp and control. If "no" is indicated for any item in Sections 1401 -1424 or 1440 -1465 , provide explanation: PS PE Y. PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M1.1 -107 DATE: 07 -29 -11 PROJECT NAME: JIMMY JOHN'S SITE ADDRESS: 728 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS. AN" klAk .sl. Bul ding Ivlon Public Works 414 N/ - Fire Prevention Structural ❑ Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete n DUE DATE: 08-02-11 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route kt Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 08-30-11 Approved n Approved with Conditions Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 Contractors or TradespeoplePer Friendly Page 1 General /Specialty Contractor A business registered as a construction contractor with LEI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name WILCOX CONSTRUCTION INC UBI No. 319007592 Phone 4257744185 Status Active Address 234 5Th Ave South License No. WILCOC'194Q0 Suite /Apt. License Type Construction Contractor City Edmonds Effective Date 11/20/1981 State WA Expiration Date 12/10/2011 Zip 98020 Suspend Date County Snohomish Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status WILCOAE376NOWILCOX, Al ELSWORTH DBA Construction Contractor General Unused 8/20/1963 12/1/1981 Archived Business Owner Information Name Role Effective Date Expiration Date LESSARD, MATTHEW J President 11/15/2010 Bond Amount HOLOBAUGH, TRENT L Secretary 11/15/2010 SV4713 CARTER, PAUL F Vice President 11/15/2010 WILCOX, ROBERT EUGENE President 11/20/1981 11/15/2010 LESSARD, MATTHEW J Secretary 11/21/2005 11/15/2010 LESSARD, JAMES MICHAEL Vice President 11/20/1981 11/21/2005 WILCOX, A E DTC0526D7304PHX10 01/01/1980 01/01/1980 WILCOX, LAURA 01/01/1980 01/01/1980 OLDS, HOWARD A Secretary 01/01/1980 01/01/1980 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 7 TRAVELERS CAS ft STY CO OF AMER SV4713 12/01/2005 Until Cancelled $12,000.0009/26 /2005 6 ST PAUL FIRE & MARINE INS CO SV4713 12/01/2002 12/01/2005 $12,000.0010/31 /2002 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 20 Charter Oak Fire Ins Co DTC0526D7304C0F11 06/01/2011 06/01/2012 $1,000,000.00 06/08/2011 19 Phoenix Insurance Company, The DTC0526D7304C0F11 06/01/2011 06/01/2012 $1,000,000.00 05/31/2011 18 THE PHOENIX INS CO DTC0526D7304PHX10 06/01/2010 06/01/2011 $1,000,000.00 06/01/2010 17 TRAVELERS PROPERTY CAS INS CO DTC0526D73041ND07 06/01/2005 06/01/2010 $1,000,000.00 05/22/2009 https://fortress.wa.gov/lni/bbip/Print.aspx 08/22/2011 EXISTING FAN POWERED VAV BOX SCHEDULE TAG MIN. SUPPLY CFM MAX. SUPPLY CFM DESIGN .' SUPPLY CFM SUPPLY FAN FINISH • HEATING ELECTRICAL DATA ' ACCESSORIES • REMARKS ELECTRICAL V /P /Hz Ventilation Rate per 2009 IMC 403 (based on ASHRAE Std. 62.1 -2007) HP EXTERNAL SP. RA NOMINAL TONS HEATER KW BTU OUTPUT VOLTS PHASE MOCP MCA yyEIGF{i- (LB) MANUFACTURER MODEL NOTES V\ 450 3000 2175 3/4 .50" 7.2 A 5.25 14.0 47,780 208 3 -- - -- -- TITUS DTQS - UNIT SIZE 6 ADJ. (VA / 26 1 OPPOSED BLADE DAMPER � DUCT MTD./ WALL MOUNT R -1 CEILING TITUS 50F • EGG CRATE ALUMINUM 26 3 284.88 LAY- IN T -BAR EGG CRATE. DW. FRAME AS. REQUIRED • LAY -IN T -BAR R -2 WALL TITUS 50F -NT • NOTES ALUMINUM 26 DIFFUSER & GRILLE SCHEDULE MARK APPLICATION • MFR. / MODEL PATTERN MAIL FINISH • BORDER ACTUAL CFM ' ACCESSORIES • REMARKS ELECTRICAL V /P /Hz Ventilation Rate per 2009 IMC 403 (based on ASHRAE Std. 62.1 -2007) REMARKS GENERAL TYPE -2 HOOD - ROOF I CAPTIVEAIRE DU30HFA LAY -IN -T -BAR • S-1. CEILING ' • TITUS /TMS • ADJ.' STEEL 26 3 Breathing Zone Outdoor Air Flow Vbz/ CFM RADIAL OPPOSED. BLADE DAMPER • DW. FRAME System Ventilation Efficiency Ev (Table 403.3.2.3.2 Min. Design Outdoor Air . Intake Flow Vot/ CFM) Minimum Outdoor Air Intake Flow CFM . 1 AS READ. S -2 SIDE TITUS •300RL ADJ. STEEL 26 1 OPPOSED BLADE DAMPER � DUCT MTD./ WALL MOUNT R -1 CEILING TITUS 50F • EGG CRATE ALUMINUM 26 3 284.88 LAY- IN T -BAR EGG CRATE. DW. FRAME AS. REQUIRED • LAY -IN T -BAR R -2 WALL TITUS 50F -NT • EGG CRATE ALUMINUM 26 1 27 N/A WALL / DUCT MTD. - • DEVICES SHALL BE TITUS OR APPROVED EQUAL. SEE SPECIFICATIONS. 5 - FLEXIBLE OR RIGID RUNOUT DUCT SIZE SHALL BE SAME SIZE AS DIFFUSER . 1.00 NECK UNLESS OTHERWISE SPECIFICALLY SHOWN ON DRAWINGS. . - MAXIMUM NC FOR ANY DEVICE WITH SPECIFIED CFM AND WIDE -OPEN DAMPER 7 SHALL BE. NO GREATER THAN NC25. ' - CEILING MODULE. SHALL BE 24X24 UNLESS OTHERWISE NOTED, PROVIDE DRYWALL FRAMES AS REQUIRED - AIR PATTERN SHALL BE 4 -WAY UNLESS SHOWN OTHERWISE ON DRAWINGS. • 446 1Minimum Outside AirVentilation Schedule TAG NUMBER AREA SERVED SO. FT. SERVED EOUIPMENT LOCATION QTY MANUFACTURER / MODEL 1 ORDINANCE CFM ACTUAL CFM 1 FAN POWER ELECTRICAL V /P /Hz Ventilation Rate per 2009 IMC 403 (based on ASHRAE Std. 62.1 -2007) REMARKS GENERAL TYPE -2 HOOD - ROOF I CAPTIVEAIRE DU30HFA I IE•ui•. Ta_ Zone Occupancy Cate:o Area sf People Outdoor Air Rate (cfm /person) Table 403.3 Zone Population. Number of people in s•ace.* Area Outdoor Air Rate (cfm /sf) Table 403.3 Occupant Density #/1000 sf) Breathing Zone Outdoor Air Flow Vbz/ CFM Zone Air Distribution Effectivene ss Ez (Table 403.3.1.2 Zone Outdoor Air Flow Voz/ CFM) System Ventilation Efficiency Ev (Table 403.3.2.3.2 Min. Design Outdoor Air . Intake Flow Vot/ CFM) Minimum Outdoor Air Intake Flow CFM Proposed Outdoor Air Intake Flow CFM 1 VAV -1 Dining Room Dining Room 498. 7.5 34 0.06 1$° 284.88 • 1.00 284.88 0.90 256 231 300 Office Office spaces 27 5.0 1 0.12 5 8.24 1.00 8.24 0.90 • . 7 7 10 Kitchen Kitchens 446 NA 6 NA NA NA NA NA NA NA 45 50. Total 282 360 * In some cases occupancy is less than maximums as allowed per 403.3 exception, in no case shall the occupancy be less than one .half per Table 403.3. EXHAUST FAN SCHEDULE TAG NUMBER AREA SERVED SO. FT. SERVED EOUIPMENT LOCATION QTY MANUFACTURER / MODEL 1 ORDINANCE CFM ACTUAL CFM TOTAL STATIC PRESSURE IN WC FAN POWER ELECTRICAL V /P /Hz WEIGHT REMARKS GENERAL TYPE -2 HOOD - ROOF 1 CAPTIVEAIRE DU30HFA 450 .50 1/4 HP 120/1/60 50 LBS 1,2,3,4,5 ® 0 1 NOTES SPEED CONTROL FOR BALANCING. TO BE INTERLOCKED WITH AC -1, FAN. SWITCH WITH ROOF CURB TO RUN CONTINUOUSLY DURING OCCUPIED HOURS 1. PROVIDE 2. FAN 3. DISCONNECT 4. FAN 5. FAN FIL COPY Permit No. 107 Plf r review approval is subject to errors and omissions. A.: ,,;Val of construction documents does not authorize t �I^fiorl of Esny adopted code or ordinance. Receipt approved Fed Copy and • , I + is acknowledged: By Date: City Of Tukwila BUILDING DIVISION SEPARATE PERMIT REQUIRED FOR: ❑ Mechanical rElectrical ErPlumbing t ! as Piping City of Tukwila E U LD NO DIVISION I\ GE\ERAL vEC A\ I CAL CO\ DITIO \S 1. THE GENERAL AND SPECIAL CONDITIONS OF THE ARCHITECTURAL SPECIFICATIONS SHALL BE INCLUDED AS PART OF THESE DOCUMENTS. 2. ALL MATERIALS SHALL BE NEW, UNUSED, AND THE BEST OF THEIR RESPECTIVE KINDS AND FREE FROM DEFECTS. 3. THE CONTRACTOR SHALL FURNISH AND INSTALL A COMPLETE AIR DISTRIBUTION SYSTEM WITHIN THE TENANT SPACE TO INCLUDE, BUT NOT LIMITED TO ALL DUCTWORK, HANGERS, INSULATION, VAPOR BARRIER, SUPPLY DIFFUSERS, RETURN GRILLES, FLEXIBLE CONNECTIONS, AND CONTROL INSTALLATION AS REQUIRED FOR A COMPLETE AND WORKING SYSTEM. THE CONTRACTOR SHALL PAY ALL FEES, GIVE ALL NOTICES, FILE ALL NECESSARY DRAWINGS AND OBTAIN ALL PERMITS AND CERTIFICATES OF APPROVAL REQUIRED IN CONNECTION WITH ALL WORK UNDER THIS CONTRACT. ALL WORK SHALL BE FURNISHED AND INSTALLED IN FULL ACCORDANCE WITH ALL LOCAL LAWS, ORDINANCES, RULES AND REGULATIONS. 4.. DRAWINGS ARE DIAGRAMMATIC ONLY, INTENDING TO SHOW GENERAL RUNS AND LOCATIONS OF THE WORK AND ARE NOT INTENDED TO BE RIGID IN SPECIFIC DETAIL. 5. THE CONTRACTOR SHALL BE HELD TO HAVE EXAMINED THE SITE FOR HIS WORK BEFORE HAVING SUBMITTED HIS PROPOSAL. NO ADDITIONAL COMPENSATION WILL BE ALLOWED. FOR CONDITIONS FOUND DURING THE COURSE OF THE CONTRACT. 6: • THE CONTRACTOR SHALL .VERIFY ALL MEASUREMENTS AT THE SITE AND BE RESPONSIBLE FOR THE CORRECTNESS 'OF THE. SAME. • 7. THE CONTRACTOR SHALL COORDINATE THE .INSTALLATION OF HIS WORK WITH LIGHTING PLANS, REFLECTED CEILING PLANS, LANDLORD'S SPRINKLER PLANS AND ALL OTHER TRADES. 8. THE INSTALLATION OF ALL EQUIPMENT AND MATERIALS REQUIRING ACCESS SHALL BE MADE IN SUCH MANNER AS TO MAKE THE EQUIPMENT AND MATERIALS READILY ACCESSIBLE FOR OPERATION, MAINTENANCE AND REPAIRS. 9. STORAGE OF CONSTRUCTION EQUIPMENT AND MATERIALS SHALL BE ONLY IN SPACES AS DESIGNATED BY THE ARCHITECT /OWNER. 10. CONSTRUCTION DEBRIS AND RUBBISH GENERATED BY THE CONTRACTOR SHALL BE REMOVED FROM PREMISES AS OFTEN AS NECESSARY OR AS DIRECTED TO MAINTAIN A CLEAN AND WORKABLE AREA. ALL WORK AND EQUIPMENT SHALL BE FULLY GUARANTEED FOR ONE (1) YEAR FROM THE DATE OF FINAL PAYMENT AND ACCEPTANCE. 12. ALL WORK, INCLUDING INSIDE OF SUPPLY AIR DUCTS, AND EQUIPMENT WITHIN THE CONTRACT AREA FURNISHED AND INSTALLED UNDER THIS CONTRACT SHALL BE. CLEANED TO THE SATISFACTION OF THE OWNER BEFORE TURNING SAME OVER TO THE OWNER. 11. 13. CONNECT NEW WORK TO EXISTING IN A NEAT AND APPROVED MANNER. 14. INTERRUPTION OF HEATING, POWER AND AUXILIARY SYSTEMS WHERE AND IF REQUIRED SHALL BE COORDINATED AND SHALL OCCUR ONLY DURING PREARRANGED ACCEPTABLE TIMES. 15. ALL DESIGN SHALL INCORPORATE CURRENT ASHRAE AND SMACNA METHODS. 16. WHEN EXISTING DUCTWORK IS UTILIZED, .SIZES SHALL BE AS SHOWN ON DWGS. AS MINIMUM REQUIREMENT. GE \ERAL \OTES A. DUCT SIZES SHOWN ARE SHEET METAL DIMENSIONS. NOT DUCT LINER. REFER TO MECHANICAL SPECIFICATIONS FOR DUCT INSULATION REQUIREMENTS. B. PROVIDE SINGLE WALL TURNING VANES © ALL ELBOWS AND TEES PER SMACNA STANDARDS. C. DO NOT PROVIDE AIR EXTRACTORS OR SPUTTER DAMPERS WHICH PROTRUDE INTO RECTANGULAR TRUNK DUCTS. PROVIDE ROUND SPIN -IN FITTINGS FOR ROUND BRANCH DUCTS. D. ROUND BRANCH DUCTS ARE SAME SIZE AS DIFFUSER WHICH THEY SERVE. E. CONTRACTOR SHALL FIELD VERIFY THE EXACT SIZE, LOCATION, AND CONDITION OF ALL EXISTING EQUIPMENT, PIPING, DUCTWORK, ETC. TO BE REUSED, RETAINED OR CONNECTED TO. CONTRACTOR SHALL COMPLY WITH ALL LANDLORD'S TENANT CRITERIA. COORDINATE AND SCHEDULE ALL WORK WITH LANDLORD'S FIELD REPRESENTATIVE. G. MAXIMUM FLEXIBLE DUCT LENGTH SHALL NOT EXCEED 5' -0 ". REFER TO MECHANICAL SPECIFICATIONS ON SHEET M -2. . H. CONTRACTOR SHALL PROCURE THE SERVICES OF A APPROVED NEBB OR AABC CERTIFIED AIR BALANCE & TESTING AGENCY TO BALANCE, ADJUST Sc TEST EQUIPMENT. CONTRACTOR SHALL BE RESPONSIBLE FOR SUBMITTING 3 COPIES OF BALANCE /TEST AGENCIES REPO RT TO TENANT. PROJECT MANAGER AND /OR LANDLORD'S REPRESENTATIVE FOR REVIEW. F. I. BALANCING OF AIR DEVICES SHALL BE ACCOMPLISHED BY ADJUSTING BRANCH TAKEOFF DAMPER AT MAIN TRUNK DUCT. DAMPERS IN THE NECKS OF AIR DEVICES SHALL BE USED FOR FINAL TRIM ONLY, AND IN NO CASE FOR GREATER THAN 10% IF THE INDICATED VOLUME FOR THE INDIVIDUAL AIR DEVICE. J. DO NOT ATTACH ANYTHING TO THE UNDERSIDE OF THE ROOF DECK. ALL LOADS AND BRACING MUST BE ADEQUATELY SUPPORTED FROM THE BUILDING ROOF STRUCTURE. K. ALL FLOOR OR, WALL PENETRATIONS SHALL BE APPROVED BY LANDLORD AND DONE IN ACCORDANCE WITH ROOF MANUFACTURERS RECOMMENDATIONS SO AS NOT TO VOID THE WARRANTY. HVAC \ OTES: 1. PROVIDE TESTING AND BALANCING FOR ALL AIR SYSTEMS. SUBMIT REPORTS TO ARCHITECT. 2. SUBMIT SHOP DRAWINGS TO ARCHITECT FOR APPROVAL OF MAJOR MECHANICAL EQUIPMENT PRIOR TO ORDERING. 3. SEE ALL OTHER DRAWINGS AND SPECIFICATIONS FOR ADDITIONAL WORK AND CLARIFICATIONS OR WORK TO BE PERFORMED. 4. SEE ARCHITECTURAL DRAWINGS FOR LOCATIONS OF DIFFUSERS, REGISTERS, GRILLES LOCATED IN THE CEILING GRID. 5. DUCTWORK LAYOUT SHOWN IS RECOMMENDED. ADJUST TO COMPLY WITH LOCAL CODE REQUIREMENTS AND AS BUILT CONDITIONS. STRUCTION TO BIDDERS REVISIONS . No changes shall be made to the scope of work without prior approval of Tukwila Building Division. N T : Revisions will require a new plan submittal and may include additional plan review fees. 1. THE CONTRACTOR SHALL USE THE EXISTING CONDENSER WATER LOOP WITH ITS CURRENT LOCATION AND ORIENTATION. 2. THE CONTRACTOR SHALL VERIFY ALL OWNER SUPPLIED AND /OR OWNER INSTALLED EQUIPMENT PRIOR TO FINALIZING THE BID. 3, THE CONTRACTOR SHALL VISIT THE SITE AND INCLUDE. IN THE BID ALL REQUIRED ACCESSORIES AND LABOR IN ORDER TO PROVIDE A COMPLETE OPERATING SYSTEM FOR THE OWNERS BENEFICIAL USE AT NO ADDITIONAL COST. INCLUDE ALL IN THE BID ALL COSTS REGARDING EXISTING CONDITIONS, RELOCATION OF PIPING OR UTILITIES WHICH MAY NOT BE SHOWN IN THE DESIGN DRAWINGS PRIOR TO FINALIZING THE BID. v ECH A. \ I CAL SPECIFICATIONS AIR BALANCING . A. CONTRACTOR SHALL PROCURE THE SERVICES OF AN INDEPENDENT NEBB OR AABC CERTIFIED AIR BALANCE AND TESTING AGENCY TO BALANCE, ADJUST & TEST EQUIPMENT. CONTRACTOR SHALL BE RESPONSIBLE FOR SUBMITTING 3 COPIES OF BALANCE /TEST AGENCIES REPORT TO P.S.S. PROJECT MANAGER AND LANDLORD OPERATIONS DIRECTOR FOR REVIEW. MIN. OUTDOOR C.F.M. AND INDOOR FAN C.F.M. SHALL BE PROVIDED AS SHOWN ON MINIMUM OUTSIDE AIR SCHEDULE. DUCTWORK A. INSTALL ALL DUCTWORK IN COMPLETE CONFORMANCE WITH RECOMMENDED CONSTRUCTION STANDARDS FOR RECTANGULAR AND ROUND SHEET METAL AND FLEXIBLE DUCTS IN ACCORDANCE WITH SMACNA DUCT CONSTRUCTION STANDARDS AND ALL OTHER AUTHORITIES HAVING JURISDICTION. FLEXIBLE DUCT SHALL NOT EXCEED 5' -0" IN LENGTH. MINIMUM SHEET METAL THICKNESS SHALL BE 26 GA. B. ALL DUCT JOINTS LONGITUDINAL AND TRANSVERSE ARE TO BE SEALED USING 181A OR 181B LISTED TAPES AND MASTICS. MECHANICAL FASTENERS MUST BE USED TO FASTEN DUCTS. STRAP HANGERS SHALL NOT BE LESS THAN 1" BY 1/8" THICK ON SIX (6) FOOT CENTERS AND ATTACHED TO SIDE OF DUCT WITH SHEET METAL SCREWS. INSULATED FLEXIBLE DUCT MAY BE USED FOR LOW PRESSURE RUNOUTS TO INDIVIDUAL DIFFUSERS IN LENGTHS NOT TO EXCEED .. FIVE (5) FEET FOR EACH DIFFUSER. SEAL ALL SHEET METAL SCREW PENETRATIONS. ALL RECTANGULAR AND ROUND SUPPLY DUCTWORK SHALL BE EXTERNALLY INSULATED WITH A MINIMUM • THICKNESS THAT CONFORMS TO THE STANDARD OF THE LOCAL CODE AND SHALL IN NO CASE BE LESS THAN 1 -1/2" AND SHALL HAVE A CONTINUOUS VAPOR BARRIER JACKET. W /ALL JOINTS TAPED AND SEALED. FRESH AIR DUCT SHALL HAVE 2" INTERNAL DUCT LINER FROM POINT OF OUTSIDE AIR CONNECTION TO POINT OF CONNECTION AT PLENUM BOX OR MIXING BOX. ALL EXPOSED SPIRAL DUCT SHALL HAVE SPIRACOUSTIC INTERNAL DUCT LINER, OR TOUGHGARD ULTRA ROUND BY CERTAINTEED. • E. PROVIDE FLEXIBLE CONNECTION BETWEEN ALL FAN POWERED EQUIPMENT AND CONNECTING DUCTWORK. F ALL INSULATION, JOINING MATERIALS, SEALER, ETC.. SHALL HAVE A U.L. FLAME SPREAD . CLASSIFICATION OF NO MORE THAN 25 AND A SMOKE DEVELOPMENT RATING NOT MORE. THAN 50. C. 3. AIR DEVICES A. SUPPLY DIFFUSERS: (TITUS AS STANDARD) SHALL BE FURNISHED WITH BAKED WHITE ENAMEL FINISH, AND SHALL BE SELECTED FOR NECK VELOCITIES NOT EXCEEDING 800 FPM AND NOISE LEVEL OF NC -35 OR LESS. B. SUPPLY DIFFUSERS SHALL BE ROUND NECK, STEEL, MODEL MCD, SIZED USING CRITERIA INDICATED ABOVE FOR LAY -IN CEILING GRID TYPE CONSTRUCTION OR DRYWALL CEILING AS INDICATED ON DWG. DIFFUSERS SHALL BE COMPLETE WITH ADJUSTABLE AIR PATTERNS AND VOLUME CONTROL DAMPERS. C RETURNS SHALL BE 22 INCH SQUARE NECK ALUM. MODEL 50F AND /OR AS NOTED ON PLANS AND AIR DEVICE SCHEDULE. FACE VELOCITY OF RETURN REGISTERS SHALL NOT EXCEED 500 FPM. VOLUME CONTROL DAMPER NOT REQUIRED FOR RETURN INSTALLATION EXCEPT WHERE NOTED. D. COORDINATE LOCATION OF AIR, DEVICES WITH LIGHTS, SPRINKLERS, SPEAKER, SMOKE DETECTORS, ETC. 4. EQUIPMENT A. REFER TO MECHANICAL PLANS. FOR SPECIFICATIONS OF HVAC EQUIPMENT. . ALL NEW EQUIPMENT SHALL LBEE EQUIVALENT \LENT TO THE SPECIFIED ITEM. . ANY ACCOMMODATIONS FOR ALTERNATE MANUFACTURERS SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. ALL EQUIPMENT SHALL BE INSTALLED ACCORDING TO MANUFACTURERS INSTRUCTIONS. D. COORDINATE UNIT LOCATION WITH LANDLORD AND SITE CONDITIONS, E. ALL PIPING AND FITTINGS LOCATED OUTDOORS AND ABOVE GRADE SHALL BE CLEANED FREE OF RUST AND PAINTED. ALL FITTINGS TO BE MADE WITH PIPE JOINT COMPOUND. TEFLON TAPE NOT ALLOWED. 5. CONTROLS A. PROVIDE CONTROLS AS SPECIFIED. SPECIAL CONTROL METHODS WILL BE ADDRESSED ON AN INDIVIDUAL BASIS. B. THE CONTRACTOR SHALL PROVIDE ALL 24V WIRING INCLUDING CONNECTIONS, CHECK, TEST AND START -UP. C. CONTRACTOR SHALL SUPPLY AND PROGRAM CONTROLS TO SATISFY THE REQUIREMENTS OF THE LOCAL ENERGY CODE. A 57 DEADBAND SHALL BE PROGRAMMED WITH CAPABILITY OF 557 HEATING AND .857 COOLING SETBACK TEMPERATURES. CONTROLS SHALL ALSO HAVE AN ACCESSIBLE 2 HOUR OCCUPANT OVERRIDE. SCOPE OF WORK: D. CONTRACTOR SHALL USING EXISTING LANDLORD'S DDC BUILDING AUTOMATION SYSTEM.. PROVIDE ALL REQUIRED ACCESSORIES, CONTROL WIRING, TESTING, CALIBRATION, ETC: AS REQUIRED IN ORDER TO PROVIDE A FULLY FUNCTIONING, TEMPERATURE CONTROLLED HVAC VAV SYSTEM FOR THIS SPACE: ENERGY CODE NOTES: 1) THERMOSTATS SHALL BE A 7 DAY PROGRAMMABLE TYPE WITH A 5 DEGREE DEADBAND AND AUTOMATIC SETBACK CONTROL PER .1412.2 WASHINGTON STATE ENERGY .CODE. 2) DUCT INSULATION AND SEALING SHALL MEET CHAPTER 14 SECTION 1414 REQUIREMENTS. 3) SUPPLY AND RETURN DUCTS IN UNCONDITIONED SPACES SHALL BE INSULATED TO MIN. R -8. ROOFTOP HVAC DUCTWORK SHALL HAVE A WEATHER BARRIER. 4) SUPPLY AND RETURN DUCTS IN CONDITIONED SPACES DO NOT REQUIRE INSULATION. DUCTS IN UNCONDITONED SPACES (I.E. ABOVE CEILING) SHALL BE R -8. 5) PIPING INSULATION SHALL MEET THE REQUIREMENTS OF WASHINGTON STATE ENERGY CODE TABLE 14 -6. 6) CONTRACTOR SHALL SUBMIT RECORD DRAWINGS AND OPERATING AND MAINTENANCE MANUALS PER 1416 WSEC. 7) CONTRACTOR SHALL PERFORM AND SUBMIT AN AIR . BALANCE . REPORT PER 1416.3.1 PER WSEC. 8) CONTRACTOR SHALL SUBMIT A COMMISSIONING REPORT AND DOCUMENTATION PER 1416.4 PER WSEC. PLAN INDEX M01 GENERAL NOTES, SCHEDULE AND LEGEND M02 FLOOR PLAN - HVAC 1 0 REVIEWED FOR CODE COMPLIANCE APPROVED AUG 19 2011 Ari 14, City of Tukwila. BUILDING DIVISION RECEIVED JUL 29 2011 PERMIT CENTER Abossein Engineering, L.L.C. MECHANICAL - ELECTRICAL CIVIL - LEED FIRE PROTECTION 2100 112TH AVE. NE BELLEVUE, WA 98004 PH: (425) 462.9441 FAX: (425) 462.9451 E-Mail: cselvice @abossein.com www.abossein.com 0 pit/ c• W SA via Wu WA 111 Z O ocl y 41 ra Os b rs U z U < Revisions ISSUE FOR JJ REVIEW \7/18/2011 A REVISION PER JIMMY LLIJOHN'S 07/26/11 REVISION PER LL /ISSUE ©FOR PERMIT 07/27/11 c wZ i- < 0 zwc z Q CD 0 uJ W LJ -� W O 0(f) ARCHITECT I HEREBY CERTIFY 1HAT THESE PLANS HAVE BEEN PRE- PARED INTER NY SIB'ERVISION, AND THAT TO THE BEST IF NY MADE, , THE SHE COIPLY VITH ALL RUES, REGULATIONS AND ORDINANCES OF TIBCVILA. VA RELATING TO STRUCTURES AND BUILDINGS. Drawn By Checked By Scale 1/4"=1'-0" Date 7/18/2011 II° -2101 Sheet No. ^ / C 1 IV (OF 2) MECHANICAL KEYED NOTES ( 1 NEW 121'0 RIGID SHEET METAL DUCTWORK. SLOPE DUCT BACK TO HOOD. TERMINATE AT ROOF WITH ROOF CAP. COORDINATE WITH LANDLORD FOR NEW ROOF PENETRATION. MAKE PENETRATION WATERTIGHT AND ALL SEALANTS AND METHODS SHALL BE COMPATIBLE WITH LANDLORD'S ROOFING SYSTEM. COORDINATE WITH LANDLORD PRIOR TO INSTALLATION. EXHAUST TERMINATION SHALL BE A MINIMUM OF 10' -0" FROM ANY OUTDOOR AIR INTAKE AND OPERABLE OPENING.. SEE DETAIL 3/M2 THIS SHEET. DUCT MOUNTED DIFFUSERS WITH OPPOSED BLADE DAMPERS. (TYPICAL) SADDLE TAP WITH VOLUME DAMPER — (TYPICAL) 20 "0 WITH Y— FITTING (T— FITTING NOT ALLOWED). TRANSITION FROM ROUND TO RECTANGULAR AT HVAC UNIT OPENING. INCLUDE FLEXIBLE CONNECTION. SHEET METAL Y— FITTING (T— FITTING NOT ALLOWED). TRANSITION FROM DUCTWORK TO HOOD COLLAR. FLEXIBLE DUCT. MAXIMUM OF 5 FEET (TYPICAL). DUCTWORK HUNG FROM STRUCTURE PER LATEST SMACNA DUCTWORK, CONSTRUCTION MANUAL. COORDINATE DUCT ROUTING WITH EXISTING ELECTRICAL, FIRE SPRINKLER, PLUMBING, ETC. — (TYPICAL) ( 9 ) 7 —DAY PROGRAMMABLE THERMOSTAT PER WASH. ENERGY CODE (TYPICAL). ( 10 ) EXHAUST AND PLUMBING VENT TERMINATIONS SHALL BE A MINIMUM OF 10 FEET FROM OUTSIDE AIR INTAKES (TYPICAL). VERIFY EXACT POINT OF CONNECTION AT SITE. COORDINATE WITH LANDLORD'S CONTRACTOR 12 "0 DUCTWORK IN SHAFT. ROOF CURB AND STUB —OUT AT ROOF AND IN TENANT SPACE BY LANDLORD. VERIFY EXACT POINT OF CONNECTION AND EXHAUST FAN ROOF CURB AT SITE. COORDINATE WITH LANDLORD'S CONTRACTOR. GENERAL NOTES ROUTE DUCTS ABOVE REFLECTED CEILING THROUGH JOISTS WHERE DUCT SIZE DOES NOT PERMIT TO INSTALL UNDER JOISTS. VERIFY EXACT LOCATIONS IN FIELD. DUCT IS TO BE MOUNTED TIGHT TO THE EXISTING . DECK /STRUCTURE. . GENERAL CONTRACTOR SHALL COORDINATE HIS WORK BETWEEN ALL TRADES (TYPICAL). HVAC LEGEND SYMBOL DESCRIPTION AIR DIFFUSER S -1 )2(SUPPLY — SUPPLY AIR DIFFUSER S -2 r:/MAX. RETURN AIR GRILLE 24x24 R -1 =4l R 1XD NOTE: • — _ RETURN AIR GRILLE R -2 .. H.E.T. WITH VOLUME ROUND SEE TAKE EXHAUST AIR GRILLE (UNLESS SHOWN OTHERWISE) WHERE FITTING NOT POSSIBLE, USE EXTRACTOR. SINGLE BRANCH TAKE -OFF 90° ELBOW — TRANSFER AIR GRILLE T -2 DAMPER . NI NI No IN FLEXIBLE DUCT SHEET METAL 90' ELBOW BACKDRAFT DAMPER -r_= === RECTANGULAR DUCT SUPPORT FROM STRUCTURE WITH 1/4" THREADED ROD 1" WIDE 22 GAUGE HANGER BAND MAX 12' -0" SPACING DUCT FITTING DETAILS NO SCALE NOTE: 1414 Ducting Systems 1414.1 Duct Sealing and Testing: Duct work and plenums shall be sealed in accordance with Section 1414.1.1. Additionally, ducts shall be tested in accordance with Sections 1414.1.2 and 1414.1.3 as required. 1414.1.1 Sealing: Duct work which is designed to operate at pressures above '' /z inch water column static pressure shall be sealed as follows: 1. Static pressure / inch to 3 inches: Seal all transverse joints and longitudinal seams. Spiral lock seams in round and flat oval duct work do not require sealing; however, other seams shall be sealed. 2. Static pressure above 3 inches: Seal all transverse joints, longitudinal seams and duct wall penetrations. All low pressure supply and return air systems not located entirely within the conditioned space, including the unconditioned side of enclosed stud bays or joist cavities /spaces used to transport air, shall be securely fastened and sealed. Duct work shall be sealed using welds, gaskets, mastic, or mastic -plus- embedded - fabric tape. Enclosed stud bays or joist cavities /spaces used to transport air shall be sealed using mastic-plus-embedded-fabric tape, or when drywall is used to enclose the air system, drywall mud and tape. Duct tape is not pennitted as a sealant on any ducts. EXCEPTION: Fibrous glass duct systems installed in accordance with Standard UL I81A and flexible duct systems installed in accordance with Standard UL 181B may use tapes listed for these systems. 1414.1.2 Low Pressure Duct Leak Test: All duct systems shall be sealed to a leakage rate not to exceed 6 percent of the fan flow if the duct system: 1. 'Is connected to a constant volume, single zone, air conditioner, heat pump or furnace; and 2. Serves less than 5,000 square feet of floor area; and 3. Has more than 25 percent duct surface area located in any unconditioned space. The leakage rate shall be confirmed through field verification and diagnostic testing, in accordance with SMACNA Duct Leakage Test Procedures - 1985.. 1414.1.3 High Pressure Duct Leak Test: Duct work that is designed to operate at static pressures in excess of 3 inches water column shall be leak- tested in accordance with SMACNA Duct Leakage Test Procedures 1985. Representative sections totaling no less than 25 percent of the total installed duct area for the designated pressure class shall be tested. Duct systems with pressure ratings in excess of 3 in. w.c. shall be identified on the drawings. The maximum permitted duct leakage shall be: Lmax = CLP0.65 Where: Lmax = Maximum permitted leakage in cfin/100 ft2 duct surface area. CL = Duct leakage class, cfm/100 ft2 at 1 in. w.c. CL = 6 for rectangular sheet metal, rectangular fibrous, and round flexible ducts. CL = 3 for round/flat oval sheet metal or fibrous glass ducts. P = Test pressure, which shall be equal to the design duct pressure class rating in w.c. MATERIALS AND Ho., SHALL BE PER SMACNA STANDARDS 24 GAUGE, ROUND SPIRAL SEAM DUCT. SEE DWG'S. FOR SIZES. SHEET METAL BOOT TO MATCH DUCT COOLER & FREEZER 111l11111 ADJACENT TENANT N.I.C. STORAGE FREEZER 6'x6' EXISTING 26X18 HIGH PRESSURE PRIMARY AIR DUCT DINING A r f' I- ROUND DUCT SPECIFICATIONS: EXPOSED ROUND DUCTWORK IN SALES AREA SHALL BE 24 GAUGE, SINGLE WALL GALVANIZED STEEL, SPIRAL LOCKSEAM. FITTINGS SHALL BE SINGLE WALL GALVANIZED STEEL, STANDING SEAM OR SOLID WELDED CONSTRUCTION. ELBOWS SHALL BE STANDING SEAM, GORED ELBOWS. GRILLE COLLARS SHALL BE ATTACHED TO THE DUCTWORK WITH POP RIVETS WITH A FINISHING FILLET OF ELASTOMER SEAL AT THE JUNCTION OF THE COLLAR TO THE DUCT. DUCT —TO —DUCT JOINTS SHALL BE MADE WITH THE SPIRAL SEAM ROTATED SO THAT THE STANDING SEAM FORMS A CONTINUOUS HELICAL PATTERN ACROSS THE JOINT. ALL DUCTWORK AND FITTINGS SHALL BE MANUFACTURED IN ACCORDANCE WITH SMACNA'S HVAC DUCT CONSTRUCTION STANDARDS LATEST EDITION. ALL EXPOSED ROUND DUCTWORK AND SIDEWALL DIFFUSER. (S2) FITTINGS IN THE SALES AREA SHALL BE CLEANED OF ALL OILS AND COATINGS PRIOR TO INSTALLATION AND PROVIDED WITH A MILL PHOSPHITIZED FINISH ( "PAINT GRIP ", "ZINC GRIP OR SIMILAR ETCH TREATMENT) TO ALLOW THE DUCTWORK TO BE PAINTED. SEE SCHEDULE SEAL ALL AROUND WITH ELASTOMER GASKET EXPOSED SPIRAL SUPPLY DUCT DETAIL NO SCALE M2 z • ui• Qz ±X-X" B.O. ROOF DECK PAINT PT -5 KITCHEN / PREP GYP. BD. SOFFIT PAINT PT-4. VERIFY EXACT POINT\ OF CONNECTION AT SITE. COORDINATE WITH LANDLORD'S CONTRACTOR MALL - N.I.C. i ■ . \ NORTH (FAN ON ROOF — BY G.C.) 10 REVIEWED FOR CODE COMPLIANCE APPROVED AUG 19 2011 City of Tukwila BUILDING DIVISION RECEIVED JUL 29 2011 PERMIT CENTER HVAC PLAN SCALE: 1/4" = 1' -0" NORTH isisimmeseem Abossein. Engineering, L.L.C. ECHANICAL - ELECTRICAL CIVIL - LEED FIRE PROTECTION 2100 112TH AVE. NE BELLEVUE, WA 98004 PH: (425) 462-9441 FAX: (425)462.9451 E -Mail: cservice @abossein.com www.abossein.com itmillf° 5 N iik el CN In WI 0 WA lift r4 z Pe 11.II a' IV 00 W I- D V) -J Ix 00 zzco 2: FL, (7) U °< I- D N •000•n aw to) 4' C -o O.wl ,.... W ?h Revisions ISSUE FOR JJ REVIEW L- 17/18/2011 REVISION PER JIMMY JOHN'S 07/26/11 REVISION PER LL /ISSUE ©FOR PERMIT 07/27/11 Q U. a_ Q CC 0 0 Li ARCHITECT I IQEBT CERTIFY THAT THESE FUNS HAVE BEEN PRE- PARED IRm R NY SIF'E'RVISB,I AND THAT 10 TIE BEST w MY KNOWLEDGE, TIE SATE COIPLY VITH ALL RULES, REGULATIONS AND ORDINANCES OF.TINVU A. V[� RELATING TO STRUCTURES AND BUILDINGS. Drawn By Checked By Scale 1/4"=1'-0" Date 7/18/2011 21C 1 Sheet No. V32. (0,2, D VOLUME (HI— EFFICIENCY TAKEOFF) DAMPER DUCT TO DIFFUSER PLAN FOR SIZE -OFF DUCTWORK MAIN r:/MAX. =4l R 1XD NOTE: • DAMPER DIFFUSER .. H.E.T. WITH VOLUME ROUND SEE TAKE (UNLESS SHOWN OTHERWISE) WHERE FITTING NOT POSSIBLE, USE EXTRACTOR. SINGLE BRANCH TAKE -OFF 90° ELBOW hl lk: SHEET METAL 90' ELBOW 36" MAX. ROUND DUCT RECTANGULAR DUCT 36" MAX. • FLEXIBLE DUCT ....., FLEXIBLE DUCT S = 2" STANDARD TWO WAY 45° WYE DIFFUSER SUPPLY AIR DIFFUSER DIFFUSER SUPPLY AIR DIFFUSER SUPPORT FROM STRUCTURE WITH 1/4" THREADED ROD 1" WIDE 22 GAUGE HANGER BAND MAX 12' -0" SPACING DUCT FITTING DETAILS NO SCALE NOTE: 1414 Ducting Systems 1414.1 Duct Sealing and Testing: Duct work and plenums shall be sealed in accordance with Section 1414.1.1. Additionally, ducts shall be tested in accordance with Sections 1414.1.2 and 1414.1.3 as required. 1414.1.1 Sealing: Duct work which is designed to operate at pressures above '' /z inch water column static pressure shall be sealed as follows: 1. Static pressure / inch to 3 inches: Seal all transverse joints and longitudinal seams. Spiral lock seams in round and flat oval duct work do not require sealing; however, other seams shall be sealed. 2. Static pressure above 3 inches: Seal all transverse joints, longitudinal seams and duct wall penetrations. All low pressure supply and return air systems not located entirely within the conditioned space, including the unconditioned side of enclosed stud bays or joist cavities /spaces used to transport air, shall be securely fastened and sealed. Duct work shall be sealed using welds, gaskets, mastic, or mastic -plus- embedded - fabric tape. Enclosed stud bays or joist cavities /spaces used to transport air shall be sealed using mastic-plus-embedded-fabric tape, or when drywall is used to enclose the air system, drywall mud and tape. Duct tape is not pennitted as a sealant on any ducts. EXCEPTION: Fibrous glass duct systems installed in accordance with Standard UL I81A and flexible duct systems installed in accordance with Standard UL 181B may use tapes listed for these systems. 1414.1.2 Low Pressure Duct Leak Test: All duct systems shall be sealed to a leakage rate not to exceed 6 percent of the fan flow if the duct system: 1. 'Is connected to a constant volume, single zone, air conditioner, heat pump or furnace; and 2. Serves less than 5,000 square feet of floor area; and 3. Has more than 25 percent duct surface area located in any unconditioned space. The leakage rate shall be confirmed through field verification and diagnostic testing, in accordance with SMACNA Duct Leakage Test Procedures - 1985.. 1414.1.3 High Pressure Duct Leak Test: Duct work that is designed to operate at static pressures in excess of 3 inches water column shall be leak- tested in accordance with SMACNA Duct Leakage Test Procedures 1985. Representative sections totaling no less than 25 percent of the total installed duct area for the designated pressure class shall be tested. Duct systems with pressure ratings in excess of 3 in. w.c. shall be identified on the drawings. The maximum permitted duct leakage shall be: Lmax = CLP0.65 Where: Lmax = Maximum permitted leakage in cfin/100 ft2 duct surface area. CL = Duct leakage class, cfm/100 ft2 at 1 in. w.c. CL = 6 for rectangular sheet metal, rectangular fibrous, and round flexible ducts. CL = 3 for round/flat oval sheet metal or fibrous glass ducts. P = Test pressure, which shall be equal to the design duct pressure class rating in w.c. MATERIALS AND Ho., SHALL BE PER SMACNA STANDARDS 24 GAUGE, ROUND SPIRAL SEAM DUCT. SEE DWG'S. FOR SIZES. SHEET METAL BOOT TO MATCH DUCT COOLER & FREEZER 111l11111 ADJACENT TENANT N.I.C. STORAGE FREEZER 6'x6' EXISTING 26X18 HIGH PRESSURE PRIMARY AIR DUCT DINING A r f' I- ROUND DUCT SPECIFICATIONS: EXPOSED ROUND DUCTWORK IN SALES AREA SHALL BE 24 GAUGE, SINGLE WALL GALVANIZED STEEL, SPIRAL LOCKSEAM. FITTINGS SHALL BE SINGLE WALL GALVANIZED STEEL, STANDING SEAM OR SOLID WELDED CONSTRUCTION. ELBOWS SHALL BE STANDING SEAM, GORED ELBOWS. GRILLE COLLARS SHALL BE ATTACHED TO THE DUCTWORK WITH POP RIVETS WITH A FINISHING FILLET OF ELASTOMER SEAL AT THE JUNCTION OF THE COLLAR TO THE DUCT. DUCT —TO —DUCT JOINTS SHALL BE MADE WITH THE SPIRAL SEAM ROTATED SO THAT THE STANDING SEAM FORMS A CONTINUOUS HELICAL PATTERN ACROSS THE JOINT. ALL DUCTWORK AND FITTINGS SHALL BE MANUFACTURED IN ACCORDANCE WITH SMACNA'S HVAC DUCT CONSTRUCTION STANDARDS LATEST EDITION. ALL EXPOSED ROUND DUCTWORK AND SIDEWALL DIFFUSER. (S2) FITTINGS IN THE SALES AREA SHALL BE CLEANED OF ALL OILS AND COATINGS PRIOR TO INSTALLATION AND PROVIDED WITH A MILL PHOSPHITIZED FINISH ( "PAINT GRIP ", "ZINC GRIP OR SIMILAR ETCH TREATMENT) TO ALLOW THE DUCTWORK TO BE PAINTED. SEE SCHEDULE SEAL ALL AROUND WITH ELASTOMER GASKET EXPOSED SPIRAL SUPPLY DUCT DETAIL NO SCALE M2 z • ui• Qz ±X-X" B.O. ROOF DECK PAINT PT -5 KITCHEN / PREP GYP. BD. SOFFIT PAINT PT-4. VERIFY EXACT POINT\ OF CONNECTION AT SITE. COORDINATE WITH LANDLORD'S CONTRACTOR MALL - N.I.C. i ■ . \ NORTH (FAN ON ROOF — BY G.C.) 10 REVIEWED FOR CODE COMPLIANCE APPROVED AUG 19 2011 City of Tukwila BUILDING DIVISION RECEIVED JUL 29 2011 PERMIT CENTER HVAC PLAN SCALE: 1/4" = 1' -0" NORTH isisimmeseem Abossein. Engineering, L.L.C. ECHANICAL - ELECTRICAL CIVIL - LEED FIRE PROTECTION 2100 112TH AVE. NE BELLEVUE, WA 98004 PH: (425) 462-9441 FAX: (425)462.9451 E -Mail: cservice @abossein.com www.abossein.com itmillf° 5 N iik el CN In WI 0 WA lift r4 z Pe 11.II a' IV 00 W I- D V) -J Ix 00 zzco 2: FL, (7) U °< I- D N •000•n aw to) 4' C -o O.wl ,.... W ?h Revisions ISSUE FOR JJ REVIEW L- 17/18/2011 REVISION PER JIMMY JOHN'S 07/26/11 REVISION PER LL /ISSUE ©FOR PERMIT 07/27/11 Q U. a_ Q CC 0 0 Li ARCHITECT I IQEBT CERTIFY THAT THESE FUNS HAVE BEEN PRE- PARED IRm R NY SIF'E'RVISB,I AND THAT 10 TIE BEST w MY KNOWLEDGE, TIE SATE COIPLY VITH ALL RULES, REGULATIONS AND ORDINANCES OF.TINVU A. V[� RELATING TO STRUCTURES AND BUILDINGS. Drawn By Checked By Scale 1/4"=1'-0" Date 7/18/2011 21C 1 Sheet No. V32. (0,2, MECHANICAL, ELECTRICAL, PLUMB ING GENERAL NOTES 1. THE M /E /P CONTRACTORS SHALL REVIEW ENTIRE SET OF CONTRACT DOCUMENTS: INCLUDING BUT NOT NECESSARILY LIMITED TO ALL ARCHITECTURAL, ALL STRUCTURAL, ALL MECHANICAL, ALL ELECTRICAL, ALL PLUMBING, AND ENTIRE PROJECT MANUAL. ELECTRICAL CONTRACTOR ACKNOWLEDGE AND INCLUDE IN THE SCOPE OF WORK (CONTRACT) ALL CONDITIONS SHALL K ( A ) PERTINENT TO THE COMPLETION OF THE ELECTRICAL WORK. ELECTRICAL CONTRACTOR SHALL •• FULLY COORDINATE ELECTRICAL WORK WITH THE INSTALLATION OF WORK BY ALL OTHER TRADES AND MAKE NECESSARY FIELD ADJUSTMENTS AS REQUIRED TO ACCOMMODATE THE ELECTRICAL INSTALLATION. ALL OF THE ABOVE SHALL BE INCLUDED IN THE SCOPE OF WORK AT NO ADDITIONAL COST TO THE OWNER: THE M /E /P CONTRACTORS SHALL CAREFULLY EXAMINE THE DRAWINGS AND SPECIFICATIONS, VISIT THE SITE OF THE WORK, AND FULLY INFORM HIMSELF AS TO ALL CONDITIONS AND MATTERS THAT CAN, IN ANY WAY, AFFECT THE WORK OR THE COST THEREOF, SHOULD THIS CONTRACTOR FIND DISCREPANCIES IN, OR OMISSIONS FROM, THE DRAWINGS, SPECIFICATIONS OR OTHER DOCUMENTS OR BE. IN DOUBT AS TO THEIR MEANING, NOTIFY THE ARCHITECT /ENGINEER AT ONCE, IN WRITING, OF ANY DISCREPANCIES BETWEEN EXISTING CONDITIONS AND NEW WORK, OR BETWEEN ELECTRICAL WORK AND THE WORK OF OTHER TRADES PRIOR AND OBTAIN CLARIFICATION PRIOR TO SUBMITTING ANY BD. LACK OF SUCH NOTIFICATION SHALL BE CONSTRUED TO INDICATE NO DISCREPANCIES OR CONFLICTING EXIST. ADDITIONAL COMPENSATION WILL NOT BE GRANTED AFTER AWARD OF CONTRACT FOR ANY WORK REQUIRED TO COMPLY WITH .THESE REQUIREMENTS. 3. THE DRAWINGS INDICATE THE DIAGRAMMATIC INTENT, GENERAL CHARACTER, REQUIREMENTS AND LOCATION OF THE WORK SHOWN AND INCLUDED. THE WORK INDICATED BUT HAVING MINOR DETAILS OBVIOUSLY OMITTED SHALL BE PROVIDED AT NO ADDITIONAL COST TO THE OWNER. 4. THE CONTRACTOR IS REQUIRED TO BID, AS SPECIFIED, ON THE . . DRAWINGS WITHOUT DEVIATION. THIS CONTRACTOR IS INVITED TO. SUBMIT SUBSTITUTIONS FROM THE BASE BID, ONLY IF THE SUBSTITUTIONS ARE APPROVED BY THE OWNER AND ENGINEER /ARCHITECT PRIOR TO SUBMITTING THE BID. 5. IT IS THE INTENT OF THESE DOCUMENTS THAT THE M /E /P CONTRACTOR PROVIDE ALL LABOR, MATERIAL, EQUIPMENT AND TOOLS FOR THE COMPLETE INSTALLATION OF ALL WORK SHOWN ON THE PLANS AND /OR DESCRIBED HEREIN, INCLUDING ALL DEVICES, CONTROLS AND APPURTENANCES REQUIRED TO SET NEW SYSTEMS INTO OPERATION. 6. THE CONTRACTOR SHALL VERIFY ALL MOUNTING, ALL ARRANGEMENTS, HEIGHTS AND LOCATIONS PRIOR TO ROUGH -IN. ANY MENTION OF A SPECIFIC MOUNTING ARRANGEMENT, HEIGHT OR LOCATION SHALL NOT RELIEVE THE CONTRACTOR OF THE RESPONSIBILITY TO VERIFY THE SPECIFIC REQUIREMENT FURNISHED OR THE OTHER TRADES WORKING IN THE SAME AREA. NO ADDITIONS TO THE CONTRACT SUM WILL BE PERMITTED FOR ITEMS INSTALLED IN WRONG LOCATIONS, IN CONFLICT WITH OTHER WORK, ETC. 7. SHOULD CONDITIONS NECESSITATE ANY REARRANGEMENTS, OR IF DUCTWORK CAN BE RUN TO BETTER ADVANTAGE, PREPARE AND SUBMIT SHOP DRAWINGS SHOWING THE CHANGES BEFORE PROCEEDING WITH THE WORK. IF SUCH CHANGES ARE APPROVED BY ARCHITECT /ENGINEER, THEY SHALL BECOME A PART OF THE CONTRACT AFTER THEIR APPROVAL. 8. UPON COMPLETION OF THE WORK, THE CONTRACTORS SHALL REVIEW AND CHECK THE ENTIRE PORTION OF WORK, CLEAN EQUIPMENT AND DEVICES, REMOVE SURPLUS MATERIALS AND RUBBISH FROM THE OWNER'S PROPERTY, LEAVING THE WORK IN NEAT AND CLEAN ORDER AND IN COMPLETE WORKING CONDITION. THE CONTRACTORS SHALL BE RESPONSIBLE FOR REMOVAL OF ANY CARTON, DEBRIS, ETC. FOR EQUIPMENT INSTALLED BY THE CONTRACTOR INCLUDING EQUIPMENT FURNISHED BY THE OWNER. THE ABOVE SHALL ALSO APPLY TO ALL EQUIPMENT FURNISHED BY OTHERS AND UNPACKED OR REMOVED FROM CARTON, BY THE CONTRACTORS. 9: THE M/P CONTRACTORS IS RESPONSIBLE FOR SCHEDULING DELIVERY, RECEIVING, UNLOADING, UNPACKING STORING SETTING IN PLACE, AND PROTECTING FROM DAMAGE, VANDALISM, THEFT OR WEATHER DURING CONSTRUCTION FOR ALL NEW EQUIPMENT FURNISHED BY THE ELECTRICAL CONTRACTOR. . 10. THE M/P CONTRACTORS SHALL PAY ALL PERMIT FEES, PLAN REVIEW FEES, LICENSE FEES, INSPECTIONS AND TAXES APPLICABLE TO THIS DIVISION AND SHALL BE INCLUDED IN THE BASE BID AS PART OF THIS CONTRACT. 11. THE M/P CONTRACTORS SHALL GUARANTEE ALL WORK AND MATERIALS FOR A PERIOD OF ONE FULL YEAR AFTER FINAL ACCEPTANCE BY THE ARCHITECT /ENGINEER AND OWNER. 12. M /E /P CONTRACTORS SHALL FURNISH CONTRACT RECORD DOCUMENTS TO THE ARCHITECT /ENGINEER BEFORE FINAL PAYMENT WILL BE ISSUED. THE CONTRACT RECORD DOCUMENTS SHALL INDICATE THE DIAGRAMMATIC INSTALLED CONDITION AND BE IN REPRODUCIBLE DRAWING FORM. 13. THE WORK INSTALLED SHALL BE IN ACCORDANCE WITH ALL LOCAL CODES AND THE LOCAL UTILITY COMPANY'S REQUIREMENTS. 14. ALL EQUIPMENT /DEVICES SHALL BE NEW AND /OR FIRST QUALITY AND IS TO BEAR THE APPROPRIATE UL OR CSA APPROVED LABELS FOR SPECIFIC PURPOSE. 15: MECHANICAL CONTRACTOR SHALL FURNISH AND INSTALL A COMPLETE TEMPERATURE CONTROL SYSTEM AS REQUIRED. 16. ALL THERMOSTATS SHALL BE MOUNTED AT +54" ABOVE FINISHED FLOOR (UNLESS OTHERWISE SPECIFIED). THERMOSTATS SHALL NOT INTERFERE WITH SHELVING, VENDING MACHINES, OTHER FIXTURES OR CONTROLS. . 17. THE CONTRACTOR SHALL BE LICENSED, BONDED, INSURED AND CAPABLE OF PERFORMING QUALITY WORKMANSHIP. THIS CONTRACTOR GUARANTEES ALL OF HIS WORK AND MATERIALS FOR A PERIOD OF ONE (1) FULL YEAR AND FINAL ACCEPTANCE BY THE OWNER AND ENGINEER. 18. THE MECH & PLMG CONTRS SHALL SUBMIT SHOP DRAWINGS (ONE SEPIA AND THREE PRINTS) PRIOR TO THE START OF INSTALLATION FOR . . OWNER /ARCHITECT /ENGINEER APPROVAL. 19. THE M /E /P CONTRACTORS SHALL FURNISH AS -BUILT DRAWINGS TO THE OWNER /ENGINEER BEFORE FINAL PAYMENT WILL BE ISSUED. THE AS -BUILT DRAWINGS SHALL BE SUBMITTED IN REPRODUCIBLE FORM. 20. THE M /E /P CONTRACTORS SHALL BE RESPONSIBLE FOR THE STARTUP OF ALL HEATING, VENTING, AND AIR - CONDITIONING EQUIPMENT. 21. THE M /E /P CONTRACTORS SHALL PROVIDE A COMPETENT. OPERATING TECHNICIAN TO INSTRUCT THE OWNER IN THE OPERATION. AND • MAINTENANCE OF THE NEW EQUIPMENT. 22. DO ALL CUTTING AND PATCHING (TO ORIGINAL STATE) OF BUILDING MATERIALS AS REQUIRED FOR INSTALLATION OF A COMPLETE WORKABLE SYSTEM. 23. THIS CONTRACTOR SHALL FURNISH . AND INSTALL ALL SLEEVES THRU WALLS AND CORING THRU FLOORS. 24. PLUMBING CONTRACTOR SHALL VERIFY EXACT LOCATION OF ALL EXISTING SANITARY, STORM AND WATER SUPPLY ON THE SITE PRIOR TO THE PERFORMANCE OF ANY WORK. 25. PLUMBER SHALL PROVIDE SERVICE VALVES AT ALL BRANCH SUPPLY PIPING. SUCH SERVICE VALVES SHALL BE LOCATED ACCESSIBLY ABOVE THE CEILING. 26. PLUMBER SHALL BEFORE PLACING WATER SYSTEM IN OPERATION, CHLORINATE ENTIRE SYSTEM IN ACCORDANCE WITH THE REQUIREMENTS OF STATE AND LOCAL CODE AUTHORITY. PLUMBER TO SUPPLY CERTIFICATE OF COMPLIANCE. 27. ALL NEW SANITARY PIPING SHALL BE GIVEN A FULL. STATIC PRESSURE TEST. METHOD OF TEST AND REQUIREMENTS TO BE MET SHALL BE AS PER THE LOCAL CODE REQUIREMENTS. BY PLUMBER'. 28. PLUMBING CONTRACTOR SHALL BE RESPONSIBLE FOR THE PUMPING AND DRAINING OF TRENCHES OR PITS NECESSARY FOR THE INSTALLATION OF HIS WORK. 29. THE GENERAL CONDITIONS AND SUPPLEMENTARY GENERAL CONDITIONS SHALL BE CONSIDERED AS PART OF THIS SPECIFICATION. 30. ALL WORK TO BE IN ACCORDANCE WITH THE RULES AND REGULATION OF THE LOCAL CODE AUTHORITIES AND THE MOST RECENT EDITION OF NATIONAL ELECTRIC CODE. 31. CONTRACTOR SHALL FILE PLANS WITH AND OBTAIN APPROVALS FROM MUNICIPAL AGENCIES. ALL PERMITS AND CERTIFICATES OF INSPECTION SHALL BE OBTAINED AND PAID FOR BY THE CONTRACTOR. PERTINENT CERTIFICATES SHALL BE DELIVERED TO THE OWNER'S REPRESENTATIVE, PRIOR TO FINAL BILLING. 32. ELECTRICAL CONTRACTOR SHALL RECORD ALL FIELD CHANGES IN HIS WORK AS THE JOB. PROGRESSES; AN ACCURATE RECORD OF ALL WORK AS ACTUALLY INSTALLED. UPON COMPLETION OF THE WORK AND BEFORE FINAL PAYMENT IS AUTHORIZED, SHALL TURN OVER TO THE OWNER'S REPRESENTATIVE A RECORD SET OF PRINTS SHOWING THESE CHANGES. 33. SUBMIT MATERIAL LISTS AND SHOP DRAWINGS FOR MAJOR EQUIPMENT TO THE OWNER'S 'REPRESENTATIVE FOR REVIEW. SUBMITTALS SHALL BE IN. ACCORDANCE WITH GENERAL CONDITIONS AND SHALL, BEAR THE STAMP OF THE ELECTRICAL CONTRACTOR SHOWING THAT HE .HAS REVIEWED AND APPROVED THEM. LACK OF SUCH CONTRACTOR'S APPROVAL WILL BE CAUSE FOR REJECTION WITHOUT REVIEW BY THE OWNER. . • 34. THIS CONTRACTOR SHALL DO ALL CUTTING, CHASING, OR CHANNELING AND PATCHING REQUIRED FOR ANY WORK HEREIN SPECIFIED. ALL OPENINGS THROUGH STRUCTURALLY SUPPORTED SLABS MUST BE CORE - BORED, SLEEVED, GROUTED, SEALED AND MADE WATERPROOF. SLEEVES MUST EXTEND AT LEAST 2" AFF. ALL SLEEVES, OPENINGS, ETC. THROUGH FIRE RATED WALLS AND FLOORS SHALL BE SEALED AFTER CONDUIT INSTALLATION TO RETAIN FIRE RATING. 35. ALL ELECTRICAL WORK SHALL BE INSTALLED SO AS TO BE READILY ACCESSIBLE FOR OPERATING, SERVICING, MAINTAINING AND REPAIR. HANGERS SHALL INCLUDE ALL MISCELLANEOUS STEEL, SUCH AS CHANNELS, RODS, ETC., NECESSARY FOR THE INSTALLATION OF WORK AND SHALL BE SECURED TO THE BUILDING STRUCTURE, NOT TO PIPING OR DUCTWORK. ALL CONDUIT SHALL BE CONCEALED WHERE POSSIBLE. EXPOSED CONDUIT SHALL BE RUN IN STRAIGHT LINES PARALLEL WITH OR AT RIGHT ANGLES TO COLUMN LINES AND SEPARATED AT LEAST 3" FROM WATER LINES WHEREVER THEY RUN ALONG SIDE OR ACROSS SUCH LINES. 36. EVERY PART OF THE INSTALLATION SHALL BE TESTED, OPERATED AND LEFT IN PERFECT WORKING ORDER. SHOULD TESTING REVEAL ANY OTHER DEFECTS, PROMPTLY CORRECT SUCH DEFECTS AND RERUN TESTS UNTIL THE ENTIRE INSTALLATION IS SATISFACTORY IN ALL RESPECTS. 37. GUARANTEE: CONTRACTOR IS TO GUARANTEE ALL WORK FOR A PERIOD OF ONE YEAR AFTER THE DATE OF ACCEPTANCE OF THE PROJECT BY THE OWNER. IT IS UNDERSTOOD BY HIS ACCEPTANCE OF THE CONTRACT THAT THIS CONTRACTOR WILL MAKE GOOD ANY AND ALL WORK WHICH IN ANY WAY HAS BECOME DEFECTIVE AS TO THE QUALITY OF MATERIALS AND WORKMANSHIP FOR ANY CAUSE. OTHER THAN ORDINARY WEAR AND TEAR. FOR THE SAME PERIOD, ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO THE PREMISES CAUSED BY DEFECTS IN WORKMANSHIP OR IN THE WORK OR EQUIPMENT FURNISHED AND /OR INSTALLED BY HIM. 38. THE CONTRACTOR, BEFORE FINAL ACCEPTANCE BY THE OWNER WILL BE GRANTED, SHALL CLEAN ALL LIGHTING FIXTURES, DEVICE PLATES, SERVICE FITTINGS AND OTHER ITEMS FURNISHED UNDER THIS CONTRACT. HE SHALL INSURE THAT ALL DIRECTORIES ARE IN PLACE WITH COMPLETED OR REVISED SCHEDULES AND ALL IDENTIFICATIONS AND MARKINGS OF EQUIPMENT, CABLES AND OTHER ITEMS ARE. COMPLETED. 39. THIS CONTRACTOR SHALL COORDINATE SEQUENCE OF WORK WITH ALL OTHER TRADES. CONTRACTOR SHALL VERIFY VOLTAGE OF MECHANICAL EQUIPMENT AND FLUORESCENT FIXTURE BALLASTS, PRIOR COMMENCING ANY WORK. NO REMOVALS SHALL BE MADE WITHOUT OWNER'S APPROVAL. ALL EXISTING EQUIPMENT, MATERIALS, ETC. THAT ARE NOT TO BE REUSED SHALL BE REMOVED COMPLETELY AND DISPOSED OF BY THIS CONTRACTOR. 40. THIS CONTRACTOR SHALL MAKE ARRANGEMENTS FOR TEMPORARY POWER AND SHALL PAY THE COST FOR THE UTILITY CONNECTION AND SHALL BE RESPONSIBLE FOR THE PROPER MAINTENANCE OF THE TEMPORARY WORK AND FOR THE REMOVAL OF SAME. CONTRACTOR SHALL PAY ALL UTILITY CHARGES IN CONNECTION WITH THE TEMPORARY POWER. CONTRACTOR SHALL PROVIDE GROUND FAULT PROTECTION FOR ALL POWER EQUIPMENT USED ON THE PREMISES DURING CONSTRUCTION. 41. SCOPE OF WORK CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, SUPPLIES, EQUIPMENT AND FEES REQUIRED TO COMPLETELY INSTALL, TEST AND PLACE THE HEREIN SPECIFIED EQUIPMENT, COMPONENTS, CONTROLS, AND SYSTEMS IN SERVICE. COMPLETE POWER AND LIGHTING DISTRIBUTION SYSTEMS INCLUDING ALL PANELS AND COMPLETE BRANCH CIRCUIT WIRING SYSTEM COMPLETE UTILITY MOTOR WIRING SYSTEMS (EXCEPT AS NOTED) COMPLETE LIGHTING FIXTURE INSTALLATION COMPLETE TELEPHONE CONDUIT SYSTEM. CONDUIT FROM POINT OF CONNECTION TO LANDLORD'S SYSTEM AND ALL TERMINAL DEVICES, BOXES, CONDUIT, PLATES, ETC. TEMPORARY ELECTRICAL SERVICE AS REQUIRED FOR CONSTRUCTION WIRING AND FINAL CONNECTION TO ALL SIGNS AND GRAPHICS, FURNISHED BY THE OWNER PROVISIONS FOR FIRE ALARM /SMOKE EVACUATION SYSTEM AND EXTENSION TO LANDLORD'S SYSTEM TESTING OF ALL CABLES AND CIRCUIT WIRING AFTER INSTALLATION TESTING OF ALL ELECTRICAL EQUIPMENT WARRANTY OF ALL WORK FOR A PERIOD OF ONE YEAR FROM DATED OF PROJECT CLOSE -OUT 42. ELECTRICAL SERVICE . PROVIDE ELECTRICAL AS INDICATED ON THE DRAWING. ALL WORK NOT SPECIFICALLY NOTED AS BEING BY THE LANDLORD OR THE POWER COMPANY SHALL BE PROVIDED BY THE ELECTRICAL CONTRACTOR. . CLOSELY COORDINATE ENTIRE INSTALLATION WITH THE POWER COMPANY. CONTRACTOR SHALL MAKE ARRANGEMENTS WITH THE LOCAL UTILITY FOR INSTALLATION OF METERING. 43. CONTRACTOR SHALL MAKE ARRANGEMENTS WITH THE LOCAL TELEPHONE UTILITY FOR TELEPHONE SERVICE TO THE SPACE, CONDUIT SYSTEM FOR TELEPHONE DISTRIBUTION TO THE LEASED PREMISES SHALL BE PROVIDED WHERE REQUIRED FOR UTILITY COMPANY WIRES. COORDINATE INSTALLATION OF TELEPHONE WORK AND INSTALL ALL CONDUIT FOR TELEPHONE SYSTEM. OUTLET BOXES SHALL BE 4" SQUARE MINIMUM WITH SINGLE DEVICE COVER AND TELEPHONE PLATE. PROVIDE INTERIOR TYPE 4 -D PLYWOOD 24" X 24" TO SERVE AS TELEPHONE TERMINAL BOARD 44. FURNISH ALL LABOR, MATERIALS, EQUIPMENT AND TOOLS TO PERFORM ELECTRICAL WORK SHOWN, NOTED OR SCHEDULED FOR A COMPLETE AND FINISHED INSTALLATION.. 44.1 THE WORD "PROVIDE" AS USED HEREIN MEANS TO FURNISH AND INSTALL COMPLETE. 44.2 MATERIALS, PRODUCTS AND EQUIPMENT, INCLUDING COMPONENTS THEREOF, SHALL BE NEW AND SUCH AS APPEARS ON THE UNDERWRITER'S LABORATORY LIST OF APPROVED ITEMS ANC SHALL MEET THE REQUIREMENTS OF RECOGNIZED STANDARDS. . 44.3 EQUIPMENT SHALL BE SIZED IN CONFORMITY WITH REQUIREMENTS OF THE NATIONAL ELECTRICAL CODE, THE LOCAL AND STATE CODES . 45. CONDUIT SHALL BE STANDARD STEEL, RIGID, IMC OR EMT (THIN WALL) ACCORDING TO CODE REQUIREMENTS. CONDUIT SHALL BE CONCEALED IN FINISHED AREAS, EXCEPT AS OTHERWISE APPROVED BY OWNER'S REPRESENTATIVE. 46. RACEWAYS SHALL BE SURFACE METAL TYPE OF THE SIZE AND CHANNEL REQUIRED FOR SERVICE, CONSTRUCTED OF GALVANIZED STEEL WITH SNAP -ON COVERS, WITH 1/8" MOUNTING SCREW KNOCKOUTS IN BASE APPROXIMATELY 8" O.C. PROVIDE FITTINGS INDICATED WHICH MATCH AND MATE WITH RACEWAY. FINISH WITH MANUFACTURER'S STANDARD PRIME COATING. SUITABLE FOR PAINTING. 47. ALL CONDUCTORS SHALL BE SOFT DRAWN, ANNEALED COPPER, WITH 600V INSULATION: 47.1 #10 AND SMALLER SOLID WITH SINGLE BRAID OR STRANDED # 8 AND LARGER - STRANDED WITH AT LEAST DOUBLE BRAID. MINIMUM WIRE SIZE SHALL BE #12, EXCEPT #14 MAY BE USED FOR CONTROL APPLICATIONS. 47.2 ALL WIRE AND CABLE SHALL BE NEW AND SHALL BE BROUGHT TO THE SITE IN UNBROKEN PACKAGES. 47.3 GENERAL WIRING SHALL HAVE THW, THHN OR THWN INSULATION. 47.4 ALUMINUM CONDUCTORS ARE NOT PERMITTED FOR BRANCH CIRCUIT WIRING. 47.5 WIRES SHALL BE COLOR CODED IN KEEPING WITH NEC STANDARDS 48. OUTLET BOXES AND COVERS SHALL BE ONE PIECE, GALVANIZED OR SHERARDIZED STEEL, KNOCK -OUT TYPE W /FIXTURE STUDS AS REQ. JUNCTION BOXES, PULL BOXES AND COVERS SHALL 3E GALVANIZED STEEL, CODE GAUGE AND SIZE. 49. WIRING DEVICES: WALL SWITCHES, SINGLE POLE, DOUBLE POLE, AND THREE WAY SHALL BE GENERAL DUTY, FLUSH, TOGGLE SWITCHES; SPECIFICATION GRADE, 20A, 120 /277V, WITH SCREW TERMINALS: MANUFACTURES SHALL BE HUBBELL, BRYANT, PASS AND SEYMORE, OR LEVITRON. GENERAL DUTY DUPLEX RECEPTACLES SHALL BE 2 -POLE, 3 -WIRE GROUNDING TYPE, SPECIFICATION GRADE, 20A, 125V, NEMA 5 -20R UNLESS OTHERWISE INDICATED. MANUFACTURERS SHALL BE HUBBELL, BRYANT, PASS AND SEYMORE, OR LEVITRON. GROUND FAULT INTERRUPTER RECEPTACLE SHALL BE GENERAL DUTY, DUPLEX RECEPTACLES, GROUND FAULT CIRCUIT INTERRUPTER, FEED - THROUGH TYPE, CAPABLE OF PROTECTING CONNECTED DOWNSTREAM RECEPTACLES ON A SINGLE CIRCUIT, GROUNDING TYPE UL -RATED CLASS A, GROUP 1, 20A, 120V, 60 HZ; WITH SOLID -STATE GROUND FAULT. SENSING AND SIGNALING; WITH 5 MILLIAMPERES GROUND -FAULT TRIP LEVEL; IN NEMA 5 -15R CONFIGURATION. MANUFACTURERS SHALL BE HUBBELL, BRYANT, PASS AND SEYMORE, OR LEVITRON. DUPLEX ISOLATED GROUND TYPE RECEPTACLE SHALL BE 2 -POLE, 4 -WIRE, 15A STRAIGHT BLADE DEVICE WITH SEPARATE ISOLATED GROUND AND BUILDING GROUND CONNECTIONS, IN NEMA 5 -15R CONFIGURATION, AS MANUFACTURED BY HUBBELL IG -5362. ANY RECEPTACLE THAT IS INSTALLED AT OR BELOW 37 INCHES SHALL BE INSTALLED GROUND UP AND ANY RECEPTACLE THAT IS INSTALLED AT OR ABOVE 38 INCHES SHALL BE INSTALLED GROUND DOWN. SEE DETAIL. 50. THIS CONTRACTOR SHALL PROVIDE, INSTALL AND CONNECT A COMPLETE SYSTEM OF GROUNDING FOR ALL EQUIPMENT AND STRUCTURES. A GOOD MECHANICAL AND ELECTRICAL CONNECTION SHALL BE MADE WITH APPROVED GROUNDING CONNECTORS. ELECTRICAL SYSTEM AND EQUIPMENT GROUNDS SHALL COMPLY WITH ALL THE LOCAL, STATE AND NEC CODES AND REGULATIONS. PANELS, CONDUIT SYSTEMS, MOTOR FRAMES, LIGHTING FIXTURES AND OTHER EQUIPMENT THAT ARE A PART OF THIS INSTALLATION SHALL BE SECURELY GROUNDED BOTH MECHANICALLY AND ELECTRICALLY IN ACCORDANCE WITH ALL LOCAL AND STATE CODES. MAIN GROUNDING SYSTEM SHALL BE SIZED TO CONFORM WITH SECTION 250, TABLE 250 -66 OF THE NATIONAL ELECTRICAL CODE. PROVIDE CONDUIT TO GROUND WIRE FROM DAMAGE TO AN AREA 6 FT. ABOVE FLOOR. PROTECT MAKE ALL JOINTS AND CONNECTIONS OF THE CONDUIT SYSTEM TIGHT TO MAINTAIN CONTINUITY OF. MECHANICAL AND ELECTRICAL GROUND THROUGHOUT ENTIRE SYSTEM. GROUND ALL 3 WIRE RECEPTACLES TO THE OUTLET BOXES. GROUND NEUTRAL FROM THE TRANSFORMER CONNECTED TO WATER LINE. GROUND CONDUCTOR SHALL BE SUPPLIED IN ALL NON- METALLIC CONDUIT. 51. LIGHTING PANEL BOARD SHALL BE 3- PHASE, 4 -WIRE DISTRIBUTED PHASE TYPE WITH SOLID NEUTRAL GROUND LUG, GROUND BUS AND NUMBER OF CIRCUIT BREAKERS AS SHOWN ON . THE PANEL SCHEDULE. BUSWAYS SHALL BE HARD DRAWN COPPER. CABINET SHALL BE CONSTRUCTED OF CODE GAUGE STEEL WITH HINGED DOOR HAVING DIRECTORY CARD, NEATLY AND PROPERLY INSCRIBED AND SET IN FRAME WITH TRANSPARENT COVER. . ALL BREAKERS SHALL BE BOLTED TYPE, THERMAL MAGNETIC WITH ALL TWO OR THREE POLE BREAKERS HAVING COMMON TRIP. CIRCUIT BREAKERS SHALL BE RATED FOR MINIMUM 10,000 AMP SYMMETRICAL SHORT CIRCUIT CURRENT AT 120/208V. CIRCUIT BREAKERS SERVING LIGHTING CIRCUITS SHALL BE RATED FOR SWITCH SERVICE PANELBOARDS AND BREAKERS SHALL BE AS MANUFACTURED BY SQUARE -D OR EQUAL. PANEL SHALL BE CIRCUITED SO THAT THE LOAD IS DISTRIBUTED EVENLY ACROSS ALL THREE. PHASES. 52. PROVIDE SAFETY AND DISCONNECT SWITCHES, FUSED OR NON- FUSED, AS CALLED FOR ON DRAWING AND AS REQUIRED BY THE LOCAL AND STATE CODES. SWITCHES SHALL BE HEAVY DUTY, LOAD AND HORSEPOWER RATED AS MANUFACTURED BY SQUARE -D, GENERAL ELECTRIC, OR EQUAL. SWITCH ENCLOSURE TO BE SUITABLE FOR APPLICATION. FURNISH AND INSTALL DUAL ELEMENT CURRENT LIMITING FUSES OF TYPE AND AMPACITY. DESIGNED TO PROTECT SYSTEM AGAINST AVAILABLE. SHORT CIRCUIT FAULT CURRENT. 53. IF REQUIRED: PROVIDE DRY -TYPE TRANSFORMER WHICH SHALL BE COMPLETELY ENCLOSED EXCEPT FOR VENTILATING OPENINGS WITH KVA AND VOLTAGE RATINGS AS CALLED FOR ON THE DRAWING AS MANUFACTURED BY SQUARE -D. TRANSFORMER SHALL HAVE A MINIMUM OF CLASS 155 INSULATION SYSTEM, AND A MINIMUM OF (4) 2-1/2 % TAPS BELOW AND (2) 2-1/2 % TAPS ABOVE RATED PRIMARY VOLTAGE. SOUND LEVEL SHALL BE LOW AND INSTALLATION SHALL INCLUDE VIBRATION DAMPENING MOUNTS AND FLEXIBLE STEEL CONDUIT FOR PRIMARY AND SECONDARY. 54. LIGHTING FIXTURES: THE CONTRACTOR SHALL PROVIDE A NEW LIGHTING FIXTURE OF THE TYPE SPECIFIED FOR EACH LIGHTING OUTLET SHOWN WITH COMPLETE LAMPS OR TUBES. ALL FIXTURES SHALL BE HUNG AND MOUNTED IN PLACE, PROPERLY WIRED, TESTED AND LEFT READY FOR OPERATION. 55. PAINTING OF ELECTRICAL CONDUITS, ETC. IF REQUIRED, WILL BE BY GENERAL CONTRACTOR. 56. RECEPTACLES, SWITCHES, AND COVER PLATES IN CUSTOMER AREAS ARE TO MATCH THE SURROUNDING WALL COLOR. ALL RECEPTACLES AND SWITCHES IN PREP AREA AND RESTROOMS ARE TO BE WHITE WITH STAINLESS STEEL COVER PLATES 57. FINALLY: IT IS THE INTENT THAT THE FOREGOING WORK SHALL BE COMPLETE IN EVERY RESPECT AND THAT ANY MATERIAL OR WORK NOT SPECIFICALLY MENTIONED OR SHOWN ON THE DRAWINGS, BUT NECESSARY TO FULLY COMPLETE THE WORK SHALL BE FURNISHED. THE LOCATION OF RECEPTACLES AND FIXTURES SHOWN ON THE DRAWING IS APPROXIMATE AND THE OWNER SHALL HAVE THE RIGHT TO RELOCATE ANY RECEPTACLES OR FIXTURES BEFORE THEY ARE INSTALLED WITHOUT ADDITIONAL COST. 58. NO ROMEX OR BX WILL BE PERMITTED. 59. ALL WIRE SHALL BE INSTALLED IN THIN WALL. (E.M.T.) CONDUIT UNLESS OTHERWISE NOTED. MINIMUM SIZE SHALL BE 3/4" EXCEPT FOR DROPS FOR DEVICES, SWITCH LEGS, TEMPERATURE CONTROL CONDUITS, WHERE INDICATED OR AS CALLED FOR ON DRAWINGS. 60. ALL THIN WALL FITTINGS SHALL BE OF THE STEEL COMPRESSION GLAND TYPE. 61. ALL UNDER FLOOR, UNDERGROUND OR EXPOSED -TO- WEATHER CONDUIT SHALL BE HEAVY WALL GALVANIZED RIGID STEEL. (G.R.S.), MINIMUM 3/4 ".. 62. ALL CONDUITS 2" OR LARGER SHALL BE GALVANIZED RIGID STEEL OR INTERMEDIATE METAL CONDUIT (I.M.C.). 63. ELECTRICAL CONTRACTOR SHALL INSTALL SIZE OF CONDUIT SHOWN AND AS SCHEDULED ABOVE AND SHALL NOT REDUCE SIZING OF CONDUITS TO SUIT WIRE FILL CAPACITY. 64. ALL CONDUIT FASTENERS, STRAPS, SUPPORTS ETC. MUST BE "BOLT -ON" GALVANIZED STEEL ON EXPOSED CONSTRUCTION AND IN WET AREAS. SNAP -ON BLACK METAL "CADDY" CLIPS IN METAL PARTITION WALLS AND ABOVE SUSPENDED CEILINGS WILL BE PERMITTED. ALL FASTENERS, STRAPS, CLIPS, ETC. SHALL BE UL. LISTED. FOR THEIR USE. 65. NO CONDUITS SHALL BE ROUTED THROUGH HVAC AIR DUCTS. 66. ALL CONDUIT RACEWAYS SHALL BE CONCEALED IN OR WITHIN: WALLS, CEILING CAVITY, ROOF CONSTRUCTION (WHERE APPROVED), SLAB, GRADE, ETC. UNLESS OTHERWISE NOTED. ANY RACEWAY THAT IS TO BE ROUTED EXPOSED SHALL BE APPROVED BY THE ARCHITECT /ENGINEER PRIOR TO INSTALLATION. ALL CONDUIT SHALL BE ROUTED PARALLEL OR PERPENDICULAR TO WALLS AND STRUCTURAL MEMBERS WITH 90' F BENDS WHERE REQUIRED AND SHALL BE RACKED. PULL AND JUNCTION BOXES SHALL BE HELD TO A MINIMUM. 67. NO WIREWAY, THROUGH OR JUNCTION SHALL BE UTILIZED WHERE MORE THAN 8 CONDUITS ARE ENTERING OR LEAVING. MULTIPLE WIREWAYS, TROUGHS OR JUNCTIONS SHALL BE UTILIZED. IN NO CASE SHALL FEED OR CONDUIT OR CABLING BE MIXED WITH BRANCH CONDUIT. 68. NO CONDUITS SHALL BE ROUTED ON ROOF. ELECTRICAL CONTRACTOR SHALL COORDINATE ROOF PENETRATIONS WITH MECHANICAL PIPE CURBS. WHERE CONDUIT MUST BE RUN ON ROOF, IT SHALL BE RACKED WITH OTHER TRADES WHERE POSSIBLE OR PROVIDED WITH ITS OWN ROOF RACK SUPPORT SYSTEM WITH PROPER ROOF PLATE SO AS NOT TO CAUSE DAMAGE TO ROOF COVERING. 69. ELECTRICAL CONTRACTOR SHALL FIREPROOF ALL CONDUIT OPENINGS BETWEEN FLOORS AND ANY INTERSPACE FIRE SEPARATION BLOCK WALLS WITH AN ENGINEER APPROVED UL LISTED FIRE RETARDANT MATERIAL. 70. ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL SLEEVES THRU WALLS AND CORING THRU FLOORS. ELECTRICAL CONTRACTOR SHALL WEATHERPROOF ALL PENETRATIONS THRU FOUNDATION AND EXTERIOR WALLS. 71. FINAL EQUIPMENT CONNECTION TO PILOT CONTROL DEVICES SHALL BE MADE WITH 1' -0" MINIMUM LENGTH OF FLEXIBLE CONDUIT CONNECTION (IE. SOLENOID VALVES, MOTORIZED DAMPERS, ETC.). I I 0 7 REVIEWED FOR CODE COMPLIANCE APPROVED AUG 19 2011 City of Tukwila BUILDING DIVISION RECEIVED JUL 2 9 2011. PERMIT CENTER Abossein Engineering, L.L.C. MECHANICAL - ELECTRICAL CIVIL - LEED FIRE PROTECTION 2100 112TH AVE. NE BELLEVUE, WA 98004 PH: (425) 462-9441 FAX: (425) 462-9451 E -Mail: cselvice @abossein.com www.abossein.com 1 M 0 IQ va © wA 0 031 Int WI 00 W H _J -J ' c co zIco = W 0 < gam' 1-0`5 ONO • 0 M K+ 't U • , o c, ... . m 'M• H .o q,. t 4) p°t•■. VD •r ,c, N Qi c ou. pu „tea E Q a ai z ' ._ -�, .= u=�^ Tr V Revisions ISSUE FOR JJ REVIEW 07/18/2011 A REVISION PER JIMMY LLIJOHN'S 07/26/11 REVISION PER LL /ISSUE ©FOR PERMIT 07/27/11 A SPECIFICATIONS ARCHITECT I IBM CERTIFY THAT INESr PLNS INVE BEEN PRE- PARED IRSER NY SIPERVISEN AND THAT TO TIE BEST IF NT ORAILEDGE, THE SAE C IFLY WIMH ALL RUES, REGULATIONS AND ORDINANCES IF TINNILA. WA RELATING TO STRUCTURES AND BUILDINGS. Drawn By Checked By Scale 1 /4 " =1' -0" Date 7/18/2011. r 2101 Sheet No. vEP-i (OF 2) MECHANICAL SYMBOL LIST MECH. MAT 'L & NOTES: MECHANICAL EQUIPMENT NOTES: PLUMBING. MAT L & PROC. NOTES.. SYMBOL DESCRIPTION DUCTWORK: 1. ALL DUCTWORK SHALL BE FABRICATED FROM GALVANIZED METAL IN ACCORDANCE WITH SMACNA STANDARDS FOR LOW AND MEDIUM PRESSURE DUCT CONSTRUCTION, DUCT SIZES, SHOWN INDICATE INSIDE DIMENSIONS. 2: ALL DUCTWORK ACCESS DOORS SHALL BE OF SUFFICIENT SIZE TO PERMIT EASY ACCESS AND THE SERVICING OF DAMPERS, CONTROLS, DEVICES, ETC. ACCESS DOORS SHALL BE VENTLOK COMPLETE WITH #50 HINGES WITH BRASS PINS, #100 LATCHES, DOOR GASKETS, ETC. DOORS LOCATED IN INSULATED DUCTWORK SHALL HAVE 1/2" THICK FIBERGLASS INSULATION BETWEEN TWO THICKNESS OF SHEET METAL. . 3. DUCTWORK SHALL COMPLY WITH ALL LOCAL AND STATE REGULATIONS REGARDING FIRE STOPPING, PROOFING AND DAMPERING. ACCESS DOORS OF SUFFICIENT SIZE FOR EASY ACCESS AND SERVICING SHALL BE PROVIDED AT ALL FIRE DAMPERS. 4. AIR VELOCITY IN LOW PRESSURE MAIN SUPPLY TRUNKS SHALL NOT EXCEED 1500 FPM, IN SUPPLY BRANCHES VELOCITY SHALL NOT EXCEED 1200 FPM, AND IN RETURN AIR DUCT. VELOCITY SHALL NOT EXCEED 1200 FPM. 5. MECHANICAL CONTRACTOR TO CORDINATE DUCT INSTALLATION WITH BRICK /TILE. INSTALLERS TO ENSURE PROPER CLEARANCES. DUCT INSULATION: 1. ALL SUPPLY DUCTWORK FROM. HEATING /COOLING UNITS SHALL BE LINED WITH 1 -1/2 LB DENSITY, 1/2" THICK FIBERGLASS DUCT LINER. DUCT LINING AND ADHESIVE SHALL BE IN CONFORMANCE . WITH NFPA NO. 90A STANDARDS: 2. ALL RETURN DUCTWORK WITHIN 1O' -O" OF HEATING /COOLING UNITS SHALL BE LINED WITH 1 -1/2 LB DENSITY, 1/2" THICK FIBERGLASS DUCT LINER. DUCT LINING AND ADHESIVE SHALL BE IN CONFORMANCE WITH NFPA NO. 90A STANDARDS. • 3. ALL EXHAUST DUCTWORK ON THE SUCTION SIDE OF EXHAUST FANS SHALL BE LINED WITH 1 -1/2 LB DENSITY, 1/2" THICK FIBERGLASS DUCT LINER, FOR A MINIMUM DISTANCE OF 10' -0 ". 4. ALL DUCT INSULATION SHALL HAVE A FLAME SPREAD RATING OF NOT MORE THAN 25 AND A SMOKE- DEVELOPED RATING OF NOT MORE THAN 50. DUCT SMOKE DETECTOR: - 1. DUCT SMOKE DETECTORS SHALL BE INSTALLED IN SUPPLY AND RETURN DUCTS ON ALL A/C EQUIPMENT 2000 CFM OR LARGER. ELECTRICAL CONTRACTOR TO SUPPLY AND WIRE DETECTOR. MECHANICAL CONTRACTOR TO DUCT MOUNT DETECTOR. ELECTRICAL AND MECHANICAL CONTRACTORS TO COORDINATE SIZES AND TYPES FOR INSTALLATION. GAS PIPING: 1 THIS CONTATOR SHALL DIINATE C NEW GAS LOAD,TMETER LOCAL GAS LOCATION, ANDAPRESSURE REGULATOR ASSEMBLY. 2. GAS PIPING SHALL BE SCHED. 40 BLACK CARBON STEEL, WITH MALLEABLE IRON 150 LB. FITTINGS. GAS PIPING LARGER THAN 2" SHALL BE WELDED, PIPING UNDER 2" SHALL BE THREADED CONNECTIONS. 3. GAS COCKS (CRANE #254 WITH CHECK OR EQUAL), AND DIRT LEGS „ (MIN. 6") SHALL BE INSTALLED IN THE PIPING TO EACH PIECE OF GAS FIRED EQUIPMENT. 4• BEFORE FINAL EQUIPMENT CONNECTIONS ARE MADE, PNEUMATICALLY TEST GAS PIPING AT 15 PSIG AIR PRESSURE. THE PRESSURE TEST SHALL BE DEEMED ACCEPTABLE IF THE PIPING SYSTEM HOLDS THE PRESSURE FOR FOUR (4) HOURS. TESTING SHALL BE. WITNESSED BY OWNER. • . • 1. ALL EQUIPMENT /DEVICES SHALL BE NEW AND OF FIRST RATE QUALITY (UNLESS OTHERWISE SPECIFIED) AND IS TO BEAR THE APPROPRIATE ( ) AGA, CSA OR UL APPROVED LABELS, LISTINGS, AND CERTIFICATIONS FOR THE SPECIFIC DESIGN PURPOSE. 2. ALL EQUIPMENT SOUND LEVELS. SHALL NOT EXCEED 50 DB AT PROPERTY LINE. 3• ALL INTERCONNECTING WIRING AT UNIT SHALL BE FACTORY PREWIRED AND REQUIRE ONLY ONE (1) POWER CONNECTION TO THE UNIT BY THE ELECTRICAL CONTRACTOR. DISCONNECT SWITCH SHALL BE BY THE ELECTRICAL CONTRACTOR UNLESS NOTED OTHERWISE. 4. ELECTRICAL CONTRACTOR SHALL FURNISH COMBINATION MAGNETIC STARTER - DISCONNECT SWITCHES AS REQUIRED (WEATHERPROOF FOR EQUIPMENT LOCATED OUTSIDE OF BUILDING). THE ELECTRICAL CONTRACTOR WILL. INSTALL. 5. SUBMIT EIGHT (8) COPIES OF EACH CATALOG CUT, FOR THE EQUIPMENT SPECIFIED, TO THE ARCHITECT /ENGINEER FOR APPROVAL PRIOR TO THE BEGINNING OF CONSTRUCTION. THIS CONTRACTOR SHALL ALSO ASSEMBLE PRINTED INSTRUCTIONS FOR THE OPERATION AND MAINTENANCE OF EACH ITEM INSTALLED AND BIND TOGETHER WITH EQUIPMENT CUTS AND CONTROL WIRING DIAGRAMS. SUBMIT EIGHT (8) COPIES TO THE OWNER /ARCHITECT /ENGINEER. 6. THIS CONTRACTOR SHALL FURNISH AND INSTALL ALL STRUCTURAL STEEL MEMBERS, SLEEVES, AND SHIMS REQUIRED TO LEVEL AND SUPPORT EQUIPMENT, ROOF CURBS AND EQUIPMENT SUPPORTS. MATERIALS: L ALL MATERIALS SHALL BE NEW, OF FIRST QUALITY AND UL LISTED FOR THE SPECIFIC DESIGN PURPOSE. 2. SANITARY, VENT AND STORM LINES SHALL BE CAST IRON AND AS PERMITTED BY THE LOCAL AND STATE CODE AUTHORITIES. PVC NOT PERMITTED WHERE DISCHARGE EXCEEDS 907 3. ALL WATER AND. WASTE PIPING TO BE RUN ON WARM SIDE OF INSULATION. 4. DOMESTIC SUPPLY PIPING LOCATED ABOVE. THE FINISHED FLOOR SHALL BE TYPE "L" COPPER. UNDERGROUND DOMESTIC SUPPLY PIPING SHALL BE TYPE "K" COPPER. 5. THREADED FITTINGS ON GALVANIZED STEEL PIPING SHALL • BE 150# CLASS GALVANIZED MALLEABLE IRON FITTING. CONFORMING TO ASTM A -197 SPECIFICATION. 6. FURNISH AND INSTALL UNIONS WHERE INDICATED OR NECESSARY FOR REPAIR OR SERVICE. UNIONS 2" AND SMALLER SHALL BE STANDARD GROUND JOINT BRASS TO IRON SEAT, MALLEABLE IRON, SCREWED. UNIONS 2-1/2" AND LARGER SHALL BE STANDARD CAST IRON FLANGED UNIONS 125.# CLASS. 7. VALVES SHALL BE MANUFACTURED BY CRANE, STOCKHAM. 8. DOMESTIC HOT WATER SUPPLY PIPING SHALL BE INSULATED WITH ONE OF THE FOLLOWING: (INSTALL AS RECOMMENDED BY MANUFACTURER). A. 1" THICK PREFORMED FIBERGLASS WITH "K" . FACTOR OF 0.23 MAXIMUM AT 75F. MEAN TEMPERATURE. JACKET TO BE FACTORY APPLIED KRAFT PAPER WITH VAPOR BARRIER. . B. 1" THICK MOLDED RIGID PHENOLIC FOAM WITH "K" FACTOR OF 0.23 MAXIMUM AT 787 MEAN TEMPERATURE WITH FACTORY APPLIED LAMINATED ALUMINUM FOIL AND . WHITE KRAFT PAPER VAPOR BARRIER JACKET. 9. DOMESTIC COLD WATER PIPING AND SUSPENDED HORIZONTAL STORM SEWERS AND ALL FITTINGS SHALL BE INSULATED WITH (INSTALL AS RECOMMENDED BY MANUFACTURER). A. 1/2" THICK INSULATION W/ FRK WRAP FOR PIPING UP TO 1 -1/4" DIAMETER. B. 1" THICK AT STORM C. SEAL BUTT & LONGITUDIAL JOINTS W/ WATERPROOF SEALANT. 10. PIPE INSULATION AT ALL PIPE HANGERS SHALL CONSIST OF INSUL- SHIELD FIBERGLASS PIPE SUPPORTS AS MANUFACTURED BY INSUL- COUSTIC OR ARCHITECT /ENGINEER APPROVED EQUAL. 11. HANGERS SHALL BE OF STANDARD WEIGHT STEEL OR IRON ROD AND RING OR CLEVIS TYPE. PROCEDURES: 1. ALL SUSPENDED HORIZONTAL PIPING SHALL BE SUPPORTED BY HANGERS SPACED NO FURTHER THAN 8' - 0" APART (4' -0" APART FOR PVC PIPING). NO PIPING. SHALL BE SELF- SUPPORTING NOR BE SUPPORTED FROM EQUIPMENT CONNECTIONS. 2. ALL PARALLEL PIPES [TWO (2) OR MORE] SHALL BE SUPPORTED ON A CHANNEL TYPE TRAPEZE HANGER. 3. SUPPORTS AND HANGERS SHALL BE INSTALLED TO PERMIT FREE EXPANSION AND CONTRACTION IN PIPING SYSTEMS UNLESS PIPE REQUIRES FIRM ANCHOR CONTROL. 4. HORIZONTAL SOIL OR WASTE LINES SHALL BE AT A SLOPE OF NOT LESS THAN 1/8" PER FOOT AND SHALL BE HELD CLOSE TO THE CONSTRUCTION TO MAINTAIN A MAXIMUM OF HEAD ROOM. ALL CHANGES OF DIRECTION AND JUNCTIONS SHALL BE MADE WITH "Y" FITTINGS AND 1/8" BENDS. NO LINES OF ANY KIND SHALL BE LOCATED BELOW FREEZERS. ALL DRAIN LINES SHALL BE PROTECTED FROM FREEZING. 5. HOT AND COLD WATER PIPING SHALL BE PROPERLY PITCHED TO LOW POINTS IN THE SYSTEM WHERE DRAINS SHALL BE INSTALLED. 6. CLEANOUTS SHALL BE PLACED AT ALL DEAD ENDS, AT CHANGES OF DIRECTION, AT 50' -0" INTERVALS ON HORIZONTAL RUNS, OUT OF HIGH TRAFFIC AREAS, (NOT UNDER CASES) ETC. WHERE CLEANOUTS OCCUR IN CONCEALED SPACES, THEY SHALL BE PROVIDED WITH EXTENSIONS TO FLOOR ABOVE OR TO WALLS. A HAND -HOLE TEST TEE SHALL BE PLACED AT THE BASE OF EACH STACK. 7. VENT STACKS EXTENDING UP THROUGH THE ROOF SHALL BE FLASHED WITH SIX POUND SHEET LEAD. FLASHING SHALL EXTEND 12" IN ALL DIRECTIONS FROM THE VENT, CARRIED OVER AND TURNED DOWN THE INSIDE OF THE VENT. ALL SEAMS AND JOINTS OF FLASHING. SHALL BE SOLDERED AND PROVEN WEATHERTIGHT. EXTEND VENTS A MIN. OF 12" ABOVE ROOF, AND 30" AWAY FROM PARAPET. 8. ALL SUPPLY PIPING TO BE RUN OVERHEAD, UNLESS NOTED OTHERWISE. g, ALL SUPPLY PIPING TO BE A MINIMUM OF 3/4" DIA. 10. EACH FIXTURE WILL HAVE A 3/4" X 12" AIR CHAMBER. 11. PROVIDE SERVICE VALVE AT BRANCHES AND AT ALL APPLIANCES. 12. ALL FIXTURES WILL BE FURNISHED WITH INTEGRAL STOPS. 13. BURIED SANITARY AND WASTE LINES WILL BE A MINIMUM OF 4" DIA. 14. ALL FLOOR DRAINS AND FIXTURES TO BE VENTED IN ACCORDANCE WITH LOCAL CODES. 15. ALL HORIZONTAL VENT PIPING SHALL BE RUN ABOVE FINISHED CEILINGS AND SLOPED UP TOWARD MAIN STACK. 16. THE PLUMBING CONTRACTOR WILL NOT INSTALL COMBUSTIBLE PIPING MATERIAL IN OR THROUGH FIRE RATED ASSEMBLIES. 17. HORIZONTAL DRAINAGE PIPING SHALL BE PITCHED NOT LESS THAN 1/4" PER FOOT FOR PIPING 3" DIA. AND UNDER. . 18. HORIZONTAL DRAINAGE PIPING SHALL BE PITCHED NOT LESS THEN 1/8" PER FOOT FOR PIPING 4" DIA. AND OVER. 19. ALL EQUIPMENT DEVICES SHALL BE INSTALLED WITH UNIONS IN SUCH A MANNER TO FACILITATE EASY REMOVAL AND P GTRE OF EQUIPMENT WITHOUT DISRUPTING SERVVICIC ATE E AND CAUSING MAJOR PIPING REVVNCE ISIONS. 20. ALL CONNECTIONS BETWEEN DISSIMILAR METALS SHALL BE MADE WITH DIELECTRIC UNIONS OR COUPLINGS. CFM CUBIC FEET OF AIR PER MINUTE DIFF DIFFUSER • EA EACH EF -# EXHAUST FAN ESP EXTERNAL STATIC PRESSURE • FBO FURNISHED BY OTHERS GR GRILLE MVD MANUAL VOLUME DAMPER NK NECK OAI OUTSIDE AIR INTAKE RTU -# ROOFTOP UNIT U -CUT UNDERCUT DOOR SUPPLY DUCT UP THRU FLOOR / ROOF I�// I� ELECTRICAL SYMBOL LIST . RETURN DUCT UP THRU FLOOR/ ROOF SYMBOL DESCRIPTION 1 MANUAL VOLUME DAMPER 4' .. A.F.F. ABOVE FINISHED FLOOR • THERMOSTAT E.C. ELECTRICAL CONTRACTOR e EQUIPMENT TAG EM INDICATES FIXTURE CONNECTED TO EMERGENCY SERVICE GAS GAS PIPING E.B.O. FURNISHED BY OTHERS GAS COCK F & I FURNISHED AND INSTALLED DT4 REDUCER GFI GROUND FAULT INTERRUPTER IN ELECTRICAL DEMOLITION NOTES: GRD TO GROUND INDICATES PANEL GROUND CONDUCTOR CONNECTED NL NIGHT LIGHT, 24 HOUR OPERATION 1. ELECTRICAL CONTRACTOR SHALL REVIEW THE ARCHITECTURAL DRAWINGS TO VERIFY THE EXTENT OF THE DEMOLITION AND REMODELING WORK. ELECTRICAL CONTRACTOR SHALL SURVEY EXISTING SITE AND DETERMINE EXTENT OF NECESSARY REALLOCATIONS. REMOVALS AND REPAIRS TO EXISTING ELECTRICAL WORK REQUIRED TO AVOID CONFLICTS WITH NEW CONSTRUCTION TO MEET MINIMUM LOCAL AND STATE CODE REQUIREMENTS. ALL ELECTRICAL OUTLETS, FIXTURES RECEPTACLES, DEVICES, ETC. NOT BEING REUSED SHALL BE REMOVED AND OUTLETS ARE TO BE CAPPED ACCORDING TO NOTE . #7: CONDUIT TO BE ABANDONED IN PLACE: AND ALL WIRING SHALL BE DISCONNECTED AT SOURCE AND REMOVED COMPLETELY. NO EXISTING JUNCTIONS OR CONDUIT COVERS SHALL BE BURIED IN NEW WALLS. ELECTRICAL CONTRACTOR TO RELOCATE SAME AS REQUIRED. A FIELD SURVEY VERIFICATION IS MANDATORY IN ORDER TO SUBMIT AN ELECTRICAL BID, FAILURE TO DO SO SHALL NOT RELIEVE THIS CONTRACTOR FROM PERFORMING THE WORK OF THIS CONTRACT. 2. EXISTING CONDUIT CAN BE REUSED PROVIDING IT IS CHECKED FOR CONTINUITY OF GROUND, BLOWN FREE OF DEBRIS, AND DOES NOT INTERFERE WITH NEW CONSTRUCTION. 3. ALL CUTTING AND PATCHING OF EXISTING PLASTER, DRYWALL, WOOD, CONCRETE ETC., FOR THE ELECTRICAL INSTALLATION IS BY THE ELECTRICAL CONTRACTOR. BEFORE ANY CUTTING, APPROVAL FROM THE ARCHITECT IS NECESSARY: CARE IS TO BE TAKEN AND ALL CUTS OR CORING ARE TO BE SQUARE - NO CHOPPING! 4. ALL EXISTING EQUIPMENT IS TO REMAIN OPERATIONAL DURING THE CONSTRUCTION PERIOD. ANY TEMPORARY WIRING OR REROUTING OF CIRCUITRY TO ACHIEVE THIS IS BY THE ELECTRICAL CONTRACTOR. SHUTDOWN OF EXISTING SERVICES SHALL ONLY BE PERMITTED UPON WRITTEN APPROVAL FROM THE OWNER AND THEN ONLY FOR THE DATE AND DURATION AGREED UPON. INCLUDE ALL PREMIUM TIME CHARGES IN THE BASE BID. 5. UNLESS INDICATED OTHERWISE, ALL LIGHTING FIXTURES, ELECTRICAL DEVICES AND ALL ITEMS OF THE EXISTING HVAC SYSTEM SHALL REMAIN UNLESS IN CONFLICT WITH REMODELING. 6. ALL LIGHTING FIXTURES REMOVED AND NOT REUSED SHALL BECOME THE PROPERTY OF THE OWNER. IF THE OWNER ELECTS NOT TO RETAIN FIXTURES, ELECTRICAL CONTRACTOR SHALL REMOVE FIXTURES FROM JOB SITE AND DISPOSE OF PROPERLY. 7. ELECTRICAL CONTRACTOR SHALL BLANK WITH PROPER FINISH PLATE IF FLUSH OUTLET EXISTS FOR ITEMS TO BE REMOVED. ANY INTERRUPTION OF CIRCUITING TO AREAS NOT BEING REMODELED SHALL BE INTERCEPTED AT A LOCATION THAT DOES NOT INTERFERE WITH NEW CONSTRUCTION. HOMERUN CIRCUITING FOR THESE INTERRUPTED CIRCUITS IS TO BE NEW WIRING. AFTER REMOVAL ALL CONTINUITY IS TO BE CHECKED FOR ALL OUTLETS IN THE AREAS NOT BEING REMODELED TO INSURE PROPER FUNCTIONING. 8. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH GENERAL CONTRACTOR FOR REMOVAL OR RELOCATION OF EXISTING ELECTRICAL EQUIPMENT (FOR EXAMPLE: LIGHTING FIXTURES, RECEPTACLES, DEVICES, CONDUIT AND WIRING) THAT WILL BE ABANDONED OR IN CONFLICT WITH NEW CONSTRUCTION. NO ADDITIONAL COST WILL BE PERMITTED. REFER TO ARCHITECTURAL DRAWINGS FOR EXTENT OF REMODELING. 9. ALL CONDUIT, DEVICES, FIXTURES, ETC. SHOWN IN THE DEMOLITION DRAWINGS TO BE REMOVED OR RELOCATED ARE ONLY FOR THE CONVENIENCE OF THE BIDDERS. ELECTRICAL CONTRACTOR SHALL FIELD VERIFY ALL ITEMS PRIOR TO SUBMITTING A BID. 10. NEW WORK AND EQUIPMENT IN THE EXISTING BUILDING HAS BEEN INDICATED ON THE DRAWINGS AS ACCURATELY AS POSSIBLE. EACH CONTRACTOR SHALL ADJUST HIS WORK AS REQUIRED TO AVOID EXISTING DUCTS, PIPES, CONDUITS AND BEAM NOT SHOWN ON PLANS. EACH CONTRACTOR SHALL ADAPT HIS WORK TO MEET ALL ACTUAL CONDITIONS ON THE EXISTING PREMISES. WP WEATHERPROOF SINGLE POLE TOGGLE SWITCH, 20 AMPERE RATED, MOUNTED 48" A.F.F. UNLESS NOTED OTHERWISE. „ „ SUBSCRIPT: a - LOWER CASE LETTER INDICATES SWITCH S CONTROL "3" - .DENOTES THREE WAY TOGGLE SWITCH "2P" - DENOTES TWO POLE TOGGLE SWITCH "P" . - DENOTES LIGHTED HANDLE TOGGLE SWITCH, LIGHT IN SWITCH SHALL LIGHT WHEN EQUIPMENT IS OPERATING "4" - DENOTES FOUR WAY TOGGLE SWITCH C� J T THERMAL OVERLOAD TOGGLE SWITCH WITH PROPERLY SIZED HEATER ELEMENTS, 48" A.F.F. UNLESS EQUIPMENT MOUNTED CONDUIT RUN ROUTED CONCEALED IN WALLS OR ABOVE • CEILING IN FINISHED. AREAS. CONDUIT EXPOSED IN UNFINISHED AREAS �- �� CONDUIT RUN ROUTED CONCEALED IN /BELOW CONCRETE SLAB OR BELOW GRADE. ! / INDICATES "GREEN" GROUND CONDUCTOR, SIZED AS NOTED ON DRAWINGS DUPLEX RECEPTACLE, 120 VOLT, 20 AMPERE RATED, 18" A.F.F. UNLESS NOTED OTHERWISE. HUBBELL OR LEVITON #5362 -I, MTD HORIZONTALLY IN JUNCTION BOX. SUBSCRIPT: "GFI" - DENOTES GROUND FAULT INTERRUPTER TYPE RECEPTACLE "IG" - DENOTES ISOLATED GROUND TYPE RECEPTACLE HUBBELL OR LEVITON #IG -5362 DOUBLE DUPLEX RECEPTACLE, 120V, 20 AMP RATED '18" A.F.F. UNLESS OTHERWISE NOTED. MOUNTED IN COMMON JUNCTION BOX. Q . „ DUPLEX RECEPTACLE, 12OV, 20 AMPERE RATED 6" ABOVE FINISHED COUNTER TOP MOUNTED HORIZONTALLY. AT LOCATIONS WHERE THERE IS NO COUNTER TOP, RECEPTACLE SHALL BE MOUNTED 40" A.F.F. SPECIAL PURPOSE RECEPTACLE, VOLTAGE, RATING AND MOUNTING AS NOTED ON .PLANS ELECTRICAL SYMBOL NOTES: JUNCTION BOX CEILING MOUNTED NOTE: JUNCTION BOX WALL MOUNTED 1. RECEPTACLES, SWITCHES, AND COVER PLATES IN DINING ROOM ARE TO MATCH THE SURROUNDING WALL FINISHES AND MOUNTED AS FOLLOWS: A. NO SUBSCRIPT INDICATED MOUNTED HORIZONTALLY B. "V" INDICATES MOUNTED VERTICALLY. 2. ALL RECEPTACLES AND SWITCHES IN PREP AREA AND RESTROOMS NEED TO BE WHITE. 3. ALL COVER PLATES IN THE PREP AREA AND RESTROOMS NEED TO BE STAINLESS STEEL. 4. ON ALL CONDUIT RUNS: A. ARROW INDICATE HOME RUN TO PANEL. B. SLASHES INDICATE QUANTITY OF WIRES. 1. SHORT SLASHES INDICATE PHASE AND SWITCH LEGS. 2. LONG SLASHES INDICATE NEUTRAL CONDUCTORS. 3. LONG SLASHES WITH DOT INDICATE GREEN GROUND CONDUCTORS. 5. DOTTED SYBOL ON PLAN INDICATES EXISTING FIXTURE, DEVICE OR EQUIPMENT. - REFER TO DEMOLITION NOTES AND SYMBOLS FOR FIXTURE INFORMATION. O JUNCTION BOX WITH FLEXIBLE CONDUIT CONNECTION , SINGLE GANG TELEPHONE OUTLET, 18" A.F.F., HORIZONTAL MOUNTED, STUB [" EMPTY CONDUIT 6" INTO ACCESSIBLE CEILING SPACE UNLESS. NOTED OTHERWISE MOTOR CONNECTION G ELECTRICAL PANEL FUSED DISCONNECT SWITCH, SIZE AND RATING AS NOTED ON DRAWINGS NON -FUSED DISCONNECT SWITCH, SIZE AND RATING AS NOTED ON DRAWING MECHANICAL EQUIPMENT TAG -SEE MECHANICAL EQUIPMENT SCHEDULE a SINGLE GANG OUTLET, 18" AFF., HORIZONTAL MOUNTED, STUB [" EMPTY CONDUIT 6" INTO ACCESSIBLE CEILING SPACE FOR CRT CABLES. CABLES F.B.O. UNLESS NOTED OTHERWISE. 11 II 107 REVIEWED FOR CODE COMPLIANCE APPROVED AUG 19, 2011 City of Tukwila BUILDING DIVISION RECEIVED JUL 29 2011 PERMIT CENTER IMEMIMMIENIEMEMIEMI Abossein. Engineering, . L.L.C. MECHANICAL - ELECTRICAL CIVIL - LEED FIRE PROTECTION 2100112TH AVE. NE BELLEVUE, WA 98004 PH: (425) 462.9441 FAX: (425) 462.9451 E -Mail: cserujce @abossein.com www.abossein.com z 0 en w GN S4 vk u Vi r+ NMI WA 111.1111 Art my' i . A O O 00 LLI D O 11 00 zwco = W 00< N -D Revisions ISSUE FOR JJ REVIEW 07/18/2011 A REVISION PER .JIMMY LLAJOHN'S 07/26/11 REVISION PER LL /ISSUE ©FOR PERMIT 07/27/11 ARCHITECT HEREBY COMFY NAT 11ESE PLANS HAVE IEEN PRE- PARED UNIER NY SUPERVISION AND THAT TO TIE BEST ff NY IOCYLEIGE, THE SALE COOLY V1Th ALL RUES, REGULATIONS AND ORDINANCES OF TUICVILA. VA RELATING TO STRUCTURES AND BUILDINGS. Drawn By Checked By Scale 1/4"=1'-0" Date 7/18/2011 It, o. 2101 Sheet No. VEP2 (0, 2)