HomeMy WebLinkAboutPermit M11-109 - WESTFIELD SOUTHCENTER MALL - JAMBA JUICEJAMBA JUICE 566 SOUThCENTER MALI. Mi 1 -109 City off ukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov MECHANICAL PERMIT Parcel No.: 9202470010 Address: 566 SOUTHCENTER MALL TUKW Project Name: JAMBA JUICE Permit Number: M11 -109 Issue Date: 10/20/2011 Permit Expires On: 04/17/2012 Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA 92013 Contact Person: Name: BRAD DERKACH Address: 3100 E RANDOL MILL RD , ARLINGTON TX 76011 Email: BDERKACH @PDMSDESIGN.COM Contractor: Name: ALPINE BUILDERS LLC Address: 12680 MUKILTEOSPEEDWAY , MUKILTEO WA 98275 Contractor License No: ALPINBL891NA Phone: 817 701 -4806 Phone: 864 - 828 -2950 Expiration Date: 08/02/2013 DESCRIPTION OF WORK: INSTALL NEW VAV BOX AND DUCTWORK Value of Mechanical: $15,000.00 Type of Fire Protection: SPRINKLERS /AFA Electrical Service Provided by: Permit Center Authorized Signature Fees Collected: $367.31 International Mechanical Code Edition: 2009 Date: Cl I hereby certify that I have read and exa ed this • • rmit and know the same to be true and correct. All provisions of law an ordinances governing this work will be complied with, wheth specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this permit. Signature: Print Name: ArtrAf This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -4/10 M11-109 Printed: 10 -20 -2011 • • PERMIT CONDITIONS Permit No. M11 -109 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Manufacturers installation instructions shall be available on the job site at the time of inspection. 7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 11: ** *FIRE DEPARTMENT CONDITIONS * ** 12: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 13: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051)(DUCT DETECTION TO BE INSTALLED ON RETURN SIDE OF VAV BOX REGARDLESS OF SIZE PER MALL ADDITION HVAC STANDARDS.) 14: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air- moving equipment upon detection of smoke in the main return -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 15: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) 16: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) 17: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 18: All fire alarm components to be tied to the main mall fire alarm panel. 19: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) doc: IMC -4/10 M11-109 Printed: 10 -20 -2011 20: An electrical permit from the CIO Tukwila Building Department Permit Cente 6- 431 -3670) is required for this project. 21: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 22: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 23: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: IMC -4/10 M11 -109 Printed: 10 -20 -2011 r • CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http: /Mrww. TukwilaWA. qov Mechanical Permit No. M l � Gil Project No. (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *please print ** SITE LOCATION Site Address: 566 Southcenter Mall Tenant Name: Jamba Juice Property Owners Name: Westfield Southcenter Mall Mailing Address: 2800 Southcenter Mall King Co Assessor's Tax No.: "ll�0 -4' 'DOI Suite Number: 1110 Floor: 1st New Tenant: ® Yes ❑..No Tukwila WA 98188 City State Zip CONTACT PERSON — who do we contact when your permit is ready to be issued Name: Brad Derkach Mailing Address: 3100 E. Randol Mill Rd. Day Telephone: (817) 701 -4806 Arlington TX —7(p01 1 E -Mail Address: BDerkach @pdmsdesign.com City State Fax Number: (817) 633 -4153 Zip MECHANICAL CONTRACTOR INFORMATION Company Name: Pe. Mailing Address: '/(f% ,A44-1&44- M%G j ?ff4cp d City State Zip Contact Person: 5AA>v l� Al D T I h 3 � r°-g,1 E -Mail Address: �l5".v'm/N /`• eAvAvAJ.0 1?11'\. Contractor Registration Number: Day a ep one: �f j k(363\ Fax Number:(pp ✓T7 `� Expiration Date: ARCHITECT OF RECORD — All plans must be stamped by architect of record Company Name: Michael Black AIA Mailing Address: 3100 E. Randoll Mill Rd. TX 76011 Contact Person: Brad Derkach E -Mail Address: BDerkach @pdmsdesign.com City State Day Telephone: (817) 701 -4806 Fax Number: (817) 633 -4153 Zip ENGINEER OF RECORD — All plans must be stamped by engineer of record Company Name: Daniel A. Reeves. P.E. Mailing Address: 3100 E. Randol Mill Rd. Contact Person: Dan Reeves TX 76011 E -Mail Address: DReeves @pdmsdesign.com H:WpplicationsWorms- Applications On Line\2010 Applications \7 -2010 - Mechanical Permit Application.doc Revised: 7 -2010 bh City State Day Telephone: (817) 633 -4200 Fax Number: (817) 633 -4153 Zip Page 1 of 2 1 • • Valuation of project (contractor's bid price): $ 15000 Scope of work (please provide detailed information): /N$TfAht- IVLN% VAV 1.oc r "bocrwGe%' Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement Fuel Type: Electric El Gas ❑ Other: Indicate type of mechanical work being installed and the quanfty below: Unit Type: Qty Unit Type: Qty . Unit Type: Qty Bioler /Compressor Qty furnace <100k btu air handling unit >10,000 cfm fire damper 0 -3 hp /100,000 btu furnace >100k btu evaporator cooler diffuser 3 3 -I5 hp /500,000 btu floor furnace ventilation fan connected to single duct thermostat AA 11 15 -30 hp /1,000,000 btu suspended/wall /floor mounted heater ventilation system wood/gas stove 30 -50 hp /1,750,000 btu appliance vent hood and duct emergency generator 50+ hp /1,750,000 btu repair or addition to heat/refrig/cooling system Incinerator - domestic other mechanical equipment air handling unit <10,000 cfm 1 1 incinerator - comm /ind PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 international building code (current edition). 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDIN�WNER OR�ORIZED AGENT: Signature: �� ' P1 Print Name:$Cu"rr j�'IZ1 Mailing Address2 'W 5o071i CP -rird2-- jt/At -L Date Application Accepted: oeb 0 Date:a/G/ /I l Day Telephone3Z3 - 5 � " 3 rok-mr City State Zip tI Date Application Expires: 02 H:\Applications \Forms - Applications On Line\2010 Applications \7.2010 - Mechanical Permit Application.doc Revised: 7 -2010 bh Staff Initials: Page 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov RECEIPT Parcel No.: 9202470010 Permit Number: M11 -109 Address: 566 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 08/01/2011 Applicant: JAMBA JUICE Issue Date: Receipt No.: R11 -02304 Initials: TLS User ID: 1670 Payment Amount: $293.85 Payment Date: 10/20/2011 01:31 PM Balance: $0.00 Payee: PB SWANN SEATTLE LLC, SEATTLE MGT ACCT TRANSACTION LIST: Type Method Descriptio Amount Payment Check 400042 293.85 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts MECHANICAL - NONRES 000.322.102.00.00 293.85 Total: $293.85 doc: Receiot -06 Printed: 10 -20 -2011 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.Tukwila WA.Roy RECEIPT Parcel No.: 9202470010 Permit Number: M11 -109 Address: 566 SOUTHCENTER MALL TUKW Status: ISSUED Suite No: Applied Date: 08/01/2011 Applicant: JAMBA JUICE Issue Date: 10/20/2011 Receipt No.: R11 -02453 Initials: User ID: JEM 1165 Payment Amount: $208.25 Payment Date: 11/09/2011 12:14 PM Balance: $0.00 Payee: CASEY J SHURM TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 01531C ACCOUNT ITEM LIST: Description 208.25 Account Code Current Pmts MECHANICAL - NONRES PLAN CHECK - NONRES 000.322.102.00.00 166.60 000.345.830 41.65 Total: $208.25 doc: Receiot -06 Printed: 11 -09 -2011 SET RECEIPT Copy Reprinted on 08 -01 -2011 at 16:52:12 08/01/2011 RECEIPT NO: R11 -01642 Initials: JEM Payment Date: 08/01/2011 User ID: 1165 Total Payment: 198.89 Payee: PRUDENCE SWANN SET ID: S000001539 SET NAME: JAMBA JUICE SET TRANSACTIONS: Set Member Amount EL11 -0711 M11 -109 PG11 -117 TOTAL: 87.63 73.46 37.80 73.46 TRANSACTION LIST: Type Method Description Amount Payment Credit C VISA 198.89 TOTAL: 198.89 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES 000.345.832.00.0 PLAN CHECK - NONRES 000.345.830 87.63 111.26 TOTAL: 198.89 INSPECTION NO. INSPECTION RECORD Retain a copy with permit /V! /1--/09 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 0. (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: �l R e�t9 IA x((1 Type of.lpspecti n: F. ' A,f9 Address: 5OP moo // Date Called: Special Instructions: Date Wanted: . F/ —re —// Requester: Phone No: Approved per applicable codes. a Corrections required prior to approval. COMMENTS: ?/^Atfriap,v/e.10//c./.,Afir (Date: I // - /v- R NSPECTION FEE RE IRED. Prior to next inspection. fee must be id at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Pro: \..10112 a J / ib r Type of Inspection: A70.04- ^.J Address: // ‹ffe,0/ 0.1.0// Date Called! Special Instructions: Date Wanted:. / a1Z,G% / a,In. p.m. Requester: Phone No: 1 Approved per applicable codes. Corrections required prior to approval. COMMENTS: Date: I A4 44 /// j AI SPECTION FEE REQUIR €D. Prio o next inspection. fee must be d at 6300 Southcenter Blvd., Suit 100. Call to schedule reinspection. INSPECTION NUMBER • ..wn - --• • :try: ." Q+ '4_ •i+ma-. . 'n 76.70 -, -mit m'4 .M INSPECTION RECORD Retain a copy with permit �+q--fir•- M I t —I V /1- F a- PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT v 444 Andover Park East, Tukwila, Wa. 98188 206 -575 -4407 Project: �. -1(41,- .c., Jvtta Type of Inspection: l y`A- l ou..1 , /mac .. F;..t 1 Address: ,, c,, SC ,c14 it Suite #: Contact Person: Special Instructions: Phone No.: Approved per applicable codes. riCorrections required prior to approval. COMMENTS: Sprinklers: - Fire Alarm: Hood & Duct: Monitor: Pre -Fire: • Permits: Occupancy Type: r.. rA- F,-‘6„ ( ok -- McLL• Fo,L1 af< I r C0 -,, ,c.0 VAV 14' 5e4 c,t kv cL f0►-aW1kSS 0Lk , Needs Shift Inspection: Sprinklers: - Fire Alarm: Hood & Duct: Monitor: Pre -Fire: • Permits: Occupancy Type: - Inspector: ,,(1 \ Date: /0-4- - R. Hrs.: / $100.60 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Address: City: Company Name: 1 State: Zip: Word /Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 • OCT -24 -2011 05:23 From: To:13602305527 P.1/1 Handling, Placement and Installation IMPORTANT: When selecting a location for the condensing unit, consideration should be given to some of the following: (a) Loading capacity of the floor or roof. Check building codes for weight distribution requirements. (b) Distance to suitable electrical supply. (c) Distance to the evaporator. {,pppy'�1f 1 (g) VIVJGIOf� I111�YW VVN..la 1YG � i��Vl VI GIIIJ „v VlV., u,,,.�IL COPY (f) Accessibility for maintenance. (g) Local building codes. ^. _ _.,._,ti p 4.. (h) Adjacent buildings relative to noise levels. (i) Wishes of the end user / owner. When all of the above points have been considered and a specific location chosen, it is advisable to obtain written approval of this location from the building and /or condensing unit owner. This may be a means of avoiding disagreement and expense at a later date. A fully qualified and properly equipped crew with the necessary tackle and rigging should be engaged to locate the condensing unit in position. When lifting the unit, spreader bars and chafing gear should be used to prevent damage. The unit should be placed on a base, which is level and even. Units should be lagged to sleepers or support base. Place unit where it will not be subject to damage by traffic or flooding. On critical installations where noise is liable to be transmitted through the floor structure, vibration isolators should be installed. Isolators should be installed under mounting base and may be rubber or cork or equal. DO NOT USE THE SHIPPING SKID AS A PERMANENT BASE. The condensing unit should be positioned to allow adequate space for performing service work. Indoor and outdoor air - cooled condensing units should be positioned using the guidelines shown below. Air Cooled Condensing Unit Minimum Clearance (for Horizontal Air Flow Units) 48" (1.2 m) Min mum �rr Width of Condensing Unit Minimum Air Flow Condensing Unit Air Flow Condensing Unit Width of Condensing Unit Minimum rr • Height of Condensing Unit Minimum c No closer than 24" (.62 m} REVISION N0:1 t411--loq /1 REVIEWED FOR CODE COMPLIANCE APPROVED NOV 0 8 2011 City of Tukwila BUILDING DIVISION Walls 1 RECEIVED OCT 2 4 2011 T 4 COMMERCIAL COOLING PAR ENGINEERING, INC. FILE C .'A r F WARNING PLEASE READ CAREFULLY PY It is important for you to inspect our Walk -in upon delivery / Installation. We will not be responsible for any damage to the Walk -in after it has been delivered. The Walk -in should not be used for storage by contractor. If you are laying tiles inside Cooler/Freezer, please make sure the Walk -in door is left open for 24 hours while grout is setting. REVIEWED FOR CODE COMPLIANCE APPROVED NOV 0 8 2011 City of Tukwila DI . DIVISION n REVISION N0._L P Manufacturer Since ECE9VED OCT 24 2011 TCEIdTER 1967 17855 E. Arenth Ave. • City of Industry, CA 91748 • 626 - 964 -8700 • 626- 964 -8777 Fax Visit us a www.commercialcooling.com M tttO' COMMERCIAL COOLING PAR ENGINEERING, INC. IMPORTANT INSTRUCTION TO INSTALL DOORS PLEASE READ ALL INSTRUCTIONS BEFORE YOU START. If you are not familiar with this type of product, please call and we will try to assist and explain the correct way to install and r':fer you to the manufacturer (for glass door and electric sliders). However we will not be responsible for installation. COLD STORAGE ROOMS WITH DOORS, ESPECIALLY SLIDING DOORS (MANUAL AND ELECTRIC) REQUIRE A FINISHED DOOR OPENING THAT IS PLUMB AND TRUE. USE A GAZER BEAM OR THE STRING SYSTEM TO MAKE SURE YOU KNOW WHAT NEEDS TO BE CORRECTED. DOORS WILL NOT SEAL IF THE OPENING IS TWISTED. THIS IS VERY CRITICAL ON FREEZERS. WARANTY IS VOIDED IN CASE OF IMPROPER INSTALLATION. Visit us @ www.commercialcooling.com Walk -In Manufacturer Sine 13. 1 967 • 1711CC 1: Arsnih Aan ('if , nF Inri,,rira rA n•1 -.in _ T_1 �rnr. .... COMMERCIAL COOLING PAR ENGINEERING, INC. Notice to the installers in the field Please review and familiarize yourself with the "as built drawing" provided in the parts box. All panels are marked on the sides which correspond to the numbers on the drawing. Floors (if included) are marked with "F ", ceilings are marked with "C" and wall panels are just numbered without a prefix. Remember the box has been preassembled in our plant and inspected prior to shipping. Every attempt has been made to stack the panels in the sequence necessary to set up with first panels needed on the top. To avoid freight damage in transit, the door / frame assembly is always on the very top and the floors are staked upside down on the bottom of the pallet. Do not over tighten the cam - locks. This will permanently damage the cam assembly & box will not seal. Cam rotations are clockwise. On large boxes the floors, walls and ceilings that are same length and standard 47" wide, will not be numbered and are all interchangeable with any other similar panels for floor, walls and ceilings. Please call our Plant Manager Joe @ (714)553 - 9731 with any questions about the above information Visit us @ www.commercialcooling.com Walk -In Manufacturer Since 1967 17855 E. Arenth Ave, City of Industry, CA 91748 • Tel (626) 964 -8700 • Fax (626) 964 -8777 I) THIS PRODUCT HAS BEEN ASSEMBLED AT OUR FACTORY PRIOR TO SHIPMENT DO NOT USE ANY TOOLS, LEAN ON, APPLY CHEMICAL OR USE FOR STORAGE. ANY DAMAGE DONE WILL BE THE RESPONSIBILTY OF THE INSTALLER/CONTRACTOR II) ACTIVATION OF CAM LOCK IS IN A CLOCKWISE ROTATION. DO NOT OVERTIGHTEN IF ROTATION IS IN A COUNTER CLOCKWISE, YOU MAY BE INSTALLING THE UNIT UPSIDE DOWN. III) FLOOR MUST BE LEVEL FOR PROPER INSTALLATION UNLEVEL FLOOR WILL RESULT IN STEPPING AND SUB STANDARD SEAL OF THE; SEAMS. IV) GALVANIZED FINISH WILL BE DAMAGED BY A) IMPROPER VENTALATION B) CLEANER CONTANING CHLOROX C) CONCRETE SEALER D) QUARRY TILE (IF NOT VENTILATED) V) DO NOT STORE ANY ITEMS ON TOP OF THE WALK -INS INSTALLATION INSTRUCTIONS 4 of 4 3/8' LAG BOLT WASHER CEILING PANEL BUTYL WALL PANEL ,;V' INTERIOR LAG DOWN CEILING PANEL CONNECTION LAQ DOWN CEILING Drill 5/16" diameter hole ® 23" O.C. Insert 3/8" x 6" lag bolt with washers and tighten down. Refer to note #4, use log down in lieu of cam —locks follow same procedure. (No connection at seams). INSTALLATION INSTRUCTIONS 1 of 4 ** EXISTING FLOOR MUST BE LEVELED FOR PROPER INSTALLATION OF THE WALK -IN COOLER OR FREEZER ** 1. Mark the perimeter outline of the structure, using chalk lines, and confirm that it is squared by making diagonal measurements. If the corner angles are square, you are ready to start installation. Installation requires a minimum of (2) installers for safety and proper erection of the walk -in. An as -built drawing will be supplied indicating dimensions & panel lay -out, each panel is identified with a number 'reflecting the as -built drawing. A review of the as -built drawing will guide you in establishing where each panel is located. Please note: There is a 1/8" tolerance allowed for each panel joint. A minimum 2" clearance should be allowed between the walk -in and adjacent walls. This clearance Is necessary for air circulation, to prevent moisture condensation and allow for any variation in building walls which may not be square or plumb. 2. COOLER: Attach a U- channel to concrete floor, floor, and power actuated fasteners. the interior face of the panel, EXTERIOR CONTINUOUS STEEL U— CHANNEL ATTACHED TO CONCRETE WITH 1/4" DRIVE PINS ® 21" O.C. ( BUTYL BETWEEN PANEL AND FLOOR using caulking on concrete Place the U-channel aligned to COVE BASE ATTACHED WITH #8 x 5/8" PAN HEAD TEK SCREWS ® 16" O.C. #8 x 5/8" TEK SCREWS 23" O.C. U— CHANNEL ALIGNED TO THE INTERIOR FACE OF THE PANEL. INSTALLATION INSTRUCTIONS 2 of 4 FREEZER: Set floor panels on concrete floor and secure sections together by tightening cam -lock fastener, using a 5/16" hex head angle wrench. COVE BASE ATTACHED WITH #8 X 5/8" PAN HEAD TEK SCREWS ® 16" O.C. BUTYL CAM -LOCK CONNECTION EXTERIOR SNAP -IN ROSETTE ASK ET BETWEEN PANELS N.S.F RADIUS FLOOR PANEL W /BACKING SECTION @ FLOOR tr. 3. Start with the back wall first. Apply generous bead of caulking to tongue side of sections. Continue with side walls and front walls, leaving door sections and appropiate corner for last. Install door leaving the comer panel loose to ease door adjusting, if necessary. Finally cam -lock all wall panels in place. CAM -LOCK CONNECTION-\ BUTYL r WALL, SNAP -IN ROSETTE GASKET BETWEEN PANELS INTERIOR WALL PANEL TO WALL PANEL CONNECTION INSTALLATION INSTRUCTIONS 3 of 4 4. Start ceiling layout, select the end ceiling panel adjacent to existing building wall. Place panel into position and properly align it with the corner and side walls, then Use a 5/16" hex head angle wrench to firmly lock the corners and wall along the back "ONLY ", do "NOT" lock ceiling panels to side walls at this time. Select the next ceiling panel per the as -built drawing and align it to the edges of the end ceiling and the perimeter walls, once squared and satisfied, cam -lock the ceiling panels along the center seam "ONLY". Continue placing the additional ceiling panels until the opposite end section is installed. Now carefully check the alignment of the ceiling with the comers and perimeter walls, once ceiling panels are squared and all Is aligned, proceed to secure wall and ceiling section together by firmly tightening cam -locks using the 5/16" hex head angle wrench. CAM -LOCK CONNECTION BUTYL WALL PANEL CEILING PANEL �- GASKET BETWEEN PANELS SNAP -IN ROSETTE INTERIOR CAM DOWN CEILING PANEL CONNECTION COMMERCIAL COOLING PAR ENGINEERING, INC. AUG 2010 COMMERCIAL COOLING SEVEN YEAR LIMITED WARRANTY Wall panels & ceiling panels (except insulated floor and walk in door) having b, :ing installed at the original job site are warranted for 7 years for the original buyer. Written notice of a claim under this warranty must be received by Seller before the expiiation of such period in order for warranty coverage to apply. Under conditions of proper installation and normal use and service, the obligation of the manufacturer under this warranty shall be limited to repairing or replacing, at the company's sole discretion, the panels that prove to be defective FOB factory. All hardware and accessories car:), a standard one year warranty. The standard warranty does not include any labor charges for repair or replacement of defective parts. In no event shall Commercial Cooling be . liable for loss of use, revenue or profit or for any other indirect, incidental, special, or consequential damage including, but not limited to, food spoilage or product loss. This warranty is in lieu of all other warranties expressed or implied and -does no: to equipment which has been subject to any accident, alteration, abuse, misuse, im groper installation or installation by an unlicensed contractor. Seller does not warrant or guarantee any equipment or accessories which a re manufactured by any party other than Commercial Cooling... FAILURE TO USE CERTIFIED OR AUTHORIZED INSTALLERS SHALL VOID ALL WARRANTIES. We do take every precaution for safe delivery, but our responsibility ceases whe:i shipment is turned over to the carrier. Our terms are F.O.B. our factory — the responsibility for all damages in transit is the carrier's whether it is visible damage or concealed damage. All claims for damage must be made by you to the carrier within 15 days of receipt for delivery. WE CANNOT ASSIST WITH ANY ISSUES ON REFRIGERATION, ELECTRICAL, DRAIN, OR INSTALLATION UNLESS THEY ARE PROVIDED BY COMMERCIAL COOLING. Welk -In Manufacturer Since 11967 17855 E. Arenth Ave City of Industry CA 91748 • Tel: 626 - 964 -8700 • Fax: 626 - 964 -8777 COMMERCIAL COOLING PAR ENGINEERING, INC. WARRANTY CONTACT INFORMATION Anthony International Ms. Sue Hooker 800 - 772 -0900, ext 4927 sueh@anthonydoors.com Commercial Display System (CDS) Mr. R. C. Calderon 800 - 478 -3790 rmcdiaz @cdsdoors.net Heatcraft Refrigerated Products Mr. Abraham Hui 866 -365 -5519 Fax Abraham.Hui a.heatcraftrpd; com Kason Industries Mr. Brian McElhiney Keeprite Mr. Shing Wong 800 -935 -2766 805- 247 -1088 Office Cell bmcelhiney@kasonind.com 714- 777 -4468 714- 276 -0677 eFax swong@k-rp.com Russell Commercial Refrigeration Mr. Phil Woods 714 -529 -1935 714 -529 -7203 Fax ph 11. woods @htpeusa.com NOV 2010 111cIk -In Manufacturer since 1967 17855 E. Arenth Ave City of Industry CA 91748 • Tel: 626- 964 -8700 • Fax: 62E- 964 -8777 BUYER BEWARE Bin/in.? walk -ins from unreliable sources can create biz problems... You are responsible for the following: • Meeting Federal Energy Independence & Security Act (EISA) requirements, including minimum R- Values • Paying state sales tax, even if your vendor doesn't • Work related injuries if your vendor has no Workers' Compensation insurance or claims exemption for owner/ operator =,' • If your vendor supplies shaded pole or PSC motors (50% cheaper) in lieu of EC motors as required by Federal law. • Using refrigerant R -404A, even if your vendor supplies R -22. 2009 Seattle Energy Code Compliance Form for Nonresidential and Multifamily Residential 2009 Seattle Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised December 2010 Project Info Project Address Southcenter Mall Date 7/28/2011 566 Southcenter Mall For Building Department Use Seattle, WA 98188 Applicant Name: samba Juice # 5561 Applicant Address: 566 Southcenter Mall Space # 1110, Seattle, WA 98188 Applicant Phone: 510- 596 -0162 FILE COPY loora. 14 /gin. REVIEWED FOR CODANCB ROVE AUG 14 201 City of Tukwila BUILDING DIVISION CARSLA AUG 012011 PERMIT CENTER N 2009 Seattle Energy Code Compliance Form for Nonresidential and Multifamily Residential Interior Lighting Summary LTG -INT 2009 Seattle Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised December 2010 Project Info Project Address Southcenter Mall Date 7/28/2011 566 Southcenter Mall For Building Department Use Seattle, WA 98188 Applicant Name: Jamba Juice # 5561 ApplicantAddress: 566 Southcenter Mall Space # 1110, Seattle, WA 98188 Applicant Phone: 510 - 596 -0162 Project Description ❑ New Building ❑ Addition ❑ Alteration ❑ Plans Included Refer to SEC Section 1513 for controls and commissioning requirements. Compliance Option 0 Prescriptive 0 Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces dearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting and the space use has not changed ❑ Less than ((60%)) 2Srk of the fixtures or of the lamps plus ballasts alone are altered. added. or replaced ((new)), installed wattage not increased. & the space use has not changed. Maximum Allowed Lighting Wattage (Interior) Location (floor plan /room #) Occupancy Description Allowed Watts per ft2** Gross Interior Area in ft2 Allowed x Area Jamba Juice Retail Sales 1.33 616 819 Sales Display Sales Display Area 0.90 175 158 Back Area L07 Recessed Mounted 2x4 4 58 232 " From Table 15-1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts 977 Proposed Lighting Wattage (Interior) Location (floor plan /room #) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Service Area LO1 Recessed Metal Halide Downlight 12 44 528 Service Area L02 Recessed Fluorescent Wall Washer 4 45 180 Back Area L07 Recessed Mounted 2x4 4 58 232 The 2009 SEC Section 1510 specifies that parking garage lighting cannot be traded with other interior Total Proposed Watts Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts 940 Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T -8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts /Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the Tamp wattage) and other criteria as specified in Section 1530. For line voltage track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or the wattage of current limiting devices or of the transformer. For low voltage track lighting list the transformer rated wattage. Parking Garage Lighting - Maximum Allowed Wattage Location Occupancy Description Allowed Watts /ft2 Gross Area (ft2) Watts Allowed Parking Garage Lighting - Proposed Wattage Location Fixture Description # of Fixtures Watts /Fixture Watts Proposed The 2009 SEC Section 1510 specifies that parking garage lighting cannot be traded with other interior Total Proposed Watts lighting or with exterior lighting. • 2009 Seattle Energy Code Compliance Form for Nonresidential and Multifamily Residential Interior Lighting Summary (back) LTG -INT 2009 Seattle Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised December 2010 Prescriptive Spaces Occupancy: 0 Warehouse or Parkina Garaae ® Other I Qualification Checklist Note: If occupancy type is "Other" and fixture answer is checked, the number of fixtures in the space is not limited by Code. Clearly indicate these spaces on plans. If not ..- • • • - . - • • • Lighting Fixtures: (Section 1521) fl Check if 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted. 1. Fluorescent fixtures a) with 1 Tamp ((2- lamps)), b) fitted with 5 to 60 watt T -1, T -2, T-4, T -5, T -8, or CFL lamps, and c) hard -wired electronic dimming ballasts and automatic dimming control for all lamps in all zones. Screw -in CFL fixtures, tracking lighting, bare lamp strip and industrial fixtures do not qualify. 2. Metal Halide with a) reflector b) ceramic MH lamps < =150w c) electronic ballasts 3. LED lights. TABLE 15 -1 Unit Liahtino Power Allowance (LPA Use' LPA2 (W /ft2) Use1 LPA2 (W /ft2) Automotive facility and aircraft maintenance 0.82 ((0:85)) Office buildings, office /administrative areas in facilities of other use types (including but not limited to schools, hospitals, 0.90 ((0:94)) Convention center 1.08 ((140)) Parking garages 0.20 Courthouse 1.05 ((440)) Penitentiary and other Group 1 -3 Occupancies 0.90 Cafeterias, fast food establishments', restaurants /bars5 0.99 ((1-20)) Police and fire stations 0.90 Dormitory 0.61 ((0:85)) Post office 0.87 ((4:00)) Dweling Units 1.00 Retail10, retail banking, mall concourses, wholesale stores (pallet rack shelving) 1.33 Exercise center 0.88 ((0,95)) School buildings (Group E Occupancy only), school classrooms, day care centers 0.99 (()) Gymnasia, assembly spaces 0.95 Theater, motion picture 0.83 ((0,97)) Health care clinic 0.87 ((1:00)) Theater, performing arts 1.25 Hospital, pharmacies. nursing homes, and other 1.20 Transportation 0.77 ((9A0)) Group 1 -1 and 1 -2 Occupancies Hotel /motel 1.00 Warehouses 0.50 Laboratory spaces (all spaces not classified laboratory" shall meet office and other appropriate 1.62 Workshops 1.20 Laundries 1.20 Libraries5 1.18 ((1 -20)) Plans Submitted for Common Areas Only Manufacturing facility 1.11 ((1-20)) Main floor building Iobbies3 (except mall concourses) 1.10 Museum 1.00 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.80 Footnotes for Table 15-1 In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. The watts per square foot may be increased, by 2% per foot of ceiling height above 20 feet, unless specifically directed otherwise by subsequent footnotes. Watts per square foot of room may be increased by 2% per foot of ceiling height above 12 feet. Reserved. Watts per square foot of room may be increased by 2% per foot of ceiling height above 9 feet. Reserved. Reserved. Reserved. Reserved. Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three- quarter- height partitions (transparent or opaque) and lighting for free - standing display where the lighting moves with the display are exempt. An additional lighting power allowance is allowed for merchandise display luminaires installed in retail sales areas that are specifically designed and directed to highlight merchandise. The following additional wattages apply: i. 0.4 ((96)) watts per square foot of sales floor area not listed in items ii and iii below; ii. 0.9 ((4.4)) watts per square foot of fumiture, clothing, cosmetics or artwork floor area; or iii. 1.5 ((2,5)) watts per square foot of jewelry, crystal or china floor area. The specified floor area for items i, ii, or iii above, and the adjoining circulation paths shall be identified and specified on building plans. Calculate the additional power allowance by multiplying the above LPDs by the sales floor area for each department excluding major circulation paths. The total additional lighting power allowance is the sum of allowances for sales categories I, ii, or iii plus an additional 1,000 watts for each separate tenant larger than 250 square feet in area. The additional wattage is allowed only if the merchandise display luminaires comply with all of the following: (a) Located on ceiling - mounted track or directly on or recessed into the ceiling itself (not on the wall). (b) Adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). This additional lighting power is allowed only if the lighting is actually installed and automatically controlled, separately from the general lighting, to be turned off during nonbusiness hours. This additional power shall be used only for the specified luminaires and shall not be used for any other purpose. Thic ardrlitinnni linhtinn nriumar is ollnwcrt nnh, if the linhtinn is inctoll=r1 2009 Seattle Energy Code Compliance Forms for Nonresidential and Multifamily Residential Mechanical Summary MECH -SUM 2009 Seattle Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised February 2011 Project Info Project Address South Center Mall Date 7/28/2011 566 Southcenter Ma11 For Building Dept. Use Seattle, WA 98188 Applicant Name: Jamba Juice # 5561 Applicant Address: 566 Southcenter Mall Space # 1110, Seattle, WA 98188 Applicant Phone: 510 -596 -0162 Project Description Briefly describe mechanical system type and features. ❑ Includes Plans Include documentation requiring compliance with commissioning requirements, Section 1416. Compliance Option 0 Simple System Q Complex System Q Systems Analysis (See Decision Flowchart (over) for qualifications. Use separate MECH -SUM for simple & complex Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. Cooling Equipment Schedule Equip. ID Equip Type Brand Name Model No.1 Capacity2 Btu /h OSA CFM or Econo? SEER or EER IPLV3 Econmizer Option or Exceptions Heat Recovery Y/N VAV -1 TITUS ATQP -12 35500 Heating Equipment Schedule Equip. ID Equip Type Brand Name' Model No.1 Capacity2 Btu /h OSA cfrn or Econo? Input Btuh Output Btuh Efficiency° Heat Recovery Y/N VAV -1 TITUS ATQP -12 37500 Fan Equipment Schedule Equip. ID Equip Type Brand Name Model No.1 CFM SP' HP /BHP Flow Controls Location of Service 'If available. 2 As tested according to Table 14-1A through 14-1G. 3 If required. ° COP, HSPF, Combustion Efficiency, or AFUE, as applicable. 5 Flow control types: variable air volume(VAV), constant volume (CV), or variable speed (VS). 6 Exception number from Section 2009 Seattle Energy Code Compliance Forms for Nonresidential and Multifamily Residential Mechanical Summary (back) MECH -SUM 2009 Seattle Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised February 2011 System Description See Section 1421 for full description of P Simple System qualifications. All Systems: ❑ No humidification? ❑ No Reheat? If Heating /Cooling or Cooling Only: ❑ Constant vol? ❑ Split system? ❑ <= 84,000 Btuh? ❑ Economizer <=13S included? Air r•.nnlarf� ❑ Parkanad cvc� ❑ < =13 nnn Rtiih9 ❑ Coolino Cap < =15 Btuh /ft2? ❑ Heating Cap. > 0 & < =10 Btuh /ft2? If Heating Only: ❑ <lrlf)n r:fm? ❑ <30% outside air? ❑ Heating Cap. < =10 Btuh /ft2? Decision Flowchart Use this flowchart to determine if project qualifies for Simple System Option. If not, either the Complex System or Systems Analysis Options must be used. ( START ) ap < =15 Heat/Cool Eq. with Cap < =10 ft2, or Yes Yes Heating /Cooling or Cooling Only No — Heating Only Reference Section 1421 Yes Yes Yes Yes • Simple System Allowed (section 1420) 4 Yes Use Complex Systems (section 1430) Complex Systems Refer to MECH -COMP Mechanical Complex Systems for assistance in determining which Complex Systems requirements are applicable to this project. 2009 Seattle Energy Code Compliance Forms for Nonresidential and Multifamily Residential Mechanical - Complex Systems Checklist MECH -COMP Forms for Nonresidential and Multifamily Residential Revised February 2011 2009 Seattle Energy Code Compliance Project Address SouthCenter Mall Date 7/28/2011 The following additional information is necessary to check a mechanical permit application for a complex mechanical system for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Use the checklist as a reference for notes added to the mechanical drawings (see the MECH -CHK checklist for additional requirements). This information must be on the plans since this is the official record of the permit. Having this infnrmatinn in senarate snerifiratinns alone is NIT an arrentahle altamative For Building Department Use Applicability (yes, no, na) Code Section Component Information Required Location on Plans Building Department Notes ADDITIONAL CHECKLIST ITEMS FOR COMPLEX SYSTEMS ONLY 1431.1 Field assem. sys. Provide calculations for total onsite energy input/output to equip. 1431.2 System Sizing Indicate equipment & system sizing complies with 1431.2 1431.3 Hydr. Sys. Design Indicate design flow rate in accordance with Table 14-3 1432.1 Setback & shut -off Indicate separate systems or show isolation devices on plans 1432.2.1 Air system reset Indicate automatic temperature reset & operation sequence 1432.2.2 Hydr. Sys. reset Indicate automatic temperature reset & operation sequence 1432.3.1 Hydr. Var. Flow Indicate variable flow method for all applicable systems 1432.3.X Hydronic Isolation Indicate method of isolation for all applicable systems 1432.4 DDC Capabilities Indicate control capabilities including demand response setpoind adj. 1432.4 DDC data mgmt Indicate metering and trending capabilities. 1432.5 Pressure Reset Indicate static pressure reset for VAV systems 1433 Air Economizer Indicate economizer on equipment schedule or provide calculations to justify exemption. Demonstrate higher efficiency equipment if required. 1433 Water Economizer Indicate water economizer and provide calculations showing compliance with 1413 if 1433 Exception 3 is utilized 1434 Separate air sys. Indicate special requirement zones and indicate systems 1435 Simul. htg. & clg. Indicate method of prohibiting simultaneous heating and cooling, or state excpetion and show supporting calculations 1436 Heat recovery Indicate heat recovery of all applicable systems on plans; complete and attach heat recovery calculations 1437 Elec. motor effic. MECH -MOT or Equip. Schedule with hp, rpm, efficiency 1438 Variable speed drives Indicate VS control or equivalent on schedules for all applicable equip. 1438.1 Heat Rejection Indicate heat rejection equipment types and fan types 1438.2 Hot Gas Bypass Indicate cooling equipment staging and capacity modulation abilities 1438.3 Large Volume sys Indicate multiple system rooms & indicate ventilation control 1439.1 Kitchen Hoods Indicate source and conditioning of make -up air 1439.2 Laboratory Exhaust Indicate HR, VAV, semi - conditioned makeup, or CERM calc no is cum u Tor any question, provide explanation: Decision Flowchart (Start Here-) Section 1411.1 Equipment Efficiency Shall Meet Tables 14 -1A through 14 -1G s/Oil Fuma input >_ 225,000 uh or Any U eate Use flowchart to determine how the requirements of the Complex Systems Option apply to the project. Refer to the indicated Code sections for complete information on the requirements. Yes $ ace > 50 with Design > 25 people per 000S 1411.1 IID & Power Venting or Damper. If input ? 225,000 Btuh then 1412.6 Modulating Controls Required Yes Section 1411.1 0.75% Maximum Jacket Loss Yes Air System Serving Multiple Zones? Section 1412.8 Ventilation Controls for High - Occupancy Areas L(continued on back) Yes Section 1431.1 Calculations of Total On -Site Energy Input & Ouput Required Yes Section 1432.2.1 Supply Air Reset Controls Required YesO. 2009 Seattle Energy Code Compliance Forms for Nonresidential and Multifamily Residential Mechanical - Complex Systems (back) 2009 Seattle Energy Code Compliance Forms for Nonresidential and Multifamily Residential MECH -COMP Revised February 2011 Hydronic System Yes Section 1432.3.2 through 1432.3.5 Device Isolation Required Yes■ Section 1432.3.1 Variable Flow Design Required dronic Syst Heated or Cooled 300,000 Btu Yes} Section 1432.2.2 Water Temperature Reset Required U 0 • Mechanical Cooling? Section 1433 Economizer Required C Present Total Cooling > 780kBtuh Section 1432.4 DDC Required With Trending and Demand Response No Supply OSA > =5000 CFM Yes` Section 1436.1 50% Effective Heat Recovery Required No Steam System Yes♦ No 4 Hour Ops, ter Cooled Conden tuh, & Servi OkB >1,50 Yes* ter Section 1436.3 Condenser Heat Recovery Required emo Refrigeration Condensers > 500kBt Yes.. Section 1436.2 Condensate Recovery Required Section 1436.4 Refrigeration Condenser Heat Recovery Required No ystem or Zone w/ Simultaneous tg. & Clg.? Yes► Section 1435 Zone Controls Must Reduce Supply Air Quantity Before Reheating /Recooling ystem o ystems serving a room have 10,000 CF PPI Yes-■ Section 1438.3 Controls Must Reduce Airflow When System In Not Heating or Cooling No Section 1438 Variable Flow Devices Required otor Ind. in Eqpmt. Covr'd by Tbl 14- 1A -14- 1G? Multi-speed Motor in Multi - eed system No-* Section 1437 Motors Must Meet Efficiencies in Table 14-4 Yes No • DONE Section 1439.1 No Heating or Cooling for at Least 50% of Make -up Air Yes Yes Section 1439.2 One Required: a. Heat Recovery per 1439.2 b. 50% VAV Exhaust & Make -up c. 75% Direct Makeup w/ Tempering Only d. Combined Energy Reduction Qer>=Qmin Yes 2009 Seattle Energy Code Compliance Forms for Nonresidential and Multifamily Residential Economizer for Nonresidential and Multifamily Residential MECH -ECO Revised February 2011 2009 Seattle Energy Code Compliance Forms Economizer Summary Check box(es) for exceptions being claimed. List the system /equipment that qualifies for each exception. See Section 1433 for full description of Economizer requirements. ❑ Full Air Econo: ❑ Ex 9b: ❑ Ex la: ❑ Ex 5: ❑ Ex 9c: ❑ Ex 1b: ❑ Ex 6: ❑ Ex 9d: ❑ Ex 2: ❑ Ex 7: ❑ Ex 9e: ❑ Ex3: Ex 8: Ex 10: ❑ Ex 4: ❑ Ex 9a: ❑ Ex 11: Decision Flowchart Use this flowchart to determine if project complies with Economizer requirements. If not, the Systems Analysis Option must be used. START Yes Reference Section 1433 poi Full Air Economizer - Complies Yes ception it Cap <54,000 B it not Exterior 'ace No xception . it Cap < 33,000 Bt nit not Exterior o djacen Idg. Cap. w/o economizer <72,000 Btuh or 5 %? ap <24, ER/EER 64 % >C Cap. w/o econo. kBtuh it Exception 2: Chilled Water Sys. ' er 25% over ptio er Cooled Re . aterside Economize 'ng chilled Sys Yes N No Exception 4: Cooling 75% Site HR or Solar ception Dehumidification with supporting rgy anal :' ception 7: Heat Pump Loop ting All Crite No No ception 10: RF System Meeting All Criteria No Does Not Comply Qualifies for Full Air Economizer Exception - Complies 2009 Seattle Ener Code Com•Hance Forms for Nonresidential and Multifamil Residential Electric Motors 2009 Seattle Energy Code Compliance Forms for Nonresidential and Multifamily Residential MECH -MOT Revised February 2011 Project Address SouthCenter Mall Date 7/28/2011 Complete the following for all design A & B squirrel -cage, T -frame induction permanently wired polyphase motors of 1 hp or more having synchronous speeds of 3600, 1800 or 1200 rpm (unless one of the exceptions below applies). For Building Department Use Motor No. or Location HP Type (open /closed) Description of Application or Use Synch. Speed Min.Nom. Full load Efficiency Minion Horrinal 'Full- Laed Efficiencies (o} As of 12/19/2010 Open Motors 1 Enclosed Motors Synchronous Speed (RPM) 3.600 1,800 1,200 I 3,600 1,800 1,200 MotorHP _ 1.0 77.0 85.5 82.5 77.0 85.5 82.5 15 84.0 86.5 86.5 84.0 86.5 87.5 2.0 85.5 86.5 87.5 85.5 86.5 88.5 3.0 85.5 89.5 88.5 86.5 89.5 .5 5.0 86.5 89.5 89.5 88.5 89.5 89.5 7.5 88.5 91.0 90.2 89.5 91.7 91.0 10.0 89.5 91.7 91.7 90.2 91.7 91.0 15.0 90.2 93.0 91.7 91.0 92.4 91.7 20:0 91.0 93.0 92.4 91.0 93.0 91.7 25.0 91.7 93.6 93.0 91.7 93.6 93.0 30.0 91.7 94.1 93.6 91.7 93.6 93.0 40.0 92.4 94.1 94.1 92.4 94.1 94.1 50.0 93.0 94.5 94.1 93.0 94.5 94.1 60.0 93.6 95.0 94.5 93.6 95.0 94.5 75.0 93.6 95.0 94.5 93.6 95.4 95.4 100.0 93.6 95.4 95.0 94.1 95.4 95.0 125.0 94.1 95.4 95.0 95.0 95.4 95.0 150.0 94.1 95.8 95.4 95.0 95.8 95.8 200.0 95.0 95.8 95.4 95.4 96.2 95.8 250.0 95.0 95.8 95.4 95.8 962 95.8 300.0 95.4 95.8 95.4 95.8 96.2 95.8 350.0 95.4 95.8 95.4 95.8 96.2 95.8 400.0 95.8 95.8 95.8 95.8 96.2 95.8 450.0 95.8 96.2 96.2 95.8 96.2 95.8 500.0 95.8 96.2 96.2 95.8 96.2 95.8 Exceptions: 1. Motors in systems designed to use more than one speed of a multi-speed motor. 2. Motors already included in the efficiency requirements for HVAC equipment (Tables 14- 1A or 14-1B) . 3. Motors that are an integral part (i.e. not easily removed and replaced) of specialized process equipment (i.e. equipment which requires a special motor, such as an explosion - proof motor). 4. Motors integral to a listed piece of equipment for which no qualifying motor has been approved (i.e. if the only U.L. listing for the equipment is with a less- efficient motor and there is no energy - efficient motor option). For motors claiming an exception, list motor and note which exception applies. 2009 Seattle Energy Code Compliance Forms for Nonresidential and Multifamily Residential 'Mechanical Permit Plans Forms for Nonresidential Checklist MECH -CHK and Multifamily Residential Revised February 2011 2009 Seattle Energy Code Compliance Project Address gouthCenter Mall (Date 7/28/2011 The following information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the 2009 Seattle Energy Code. Applicability (yes, no, na) Code Section Component Information Required Location on Plans Building Department Notes HVAC REQUIREMENTS (Sections 1401 -1424) 1411 Equipment Performance 1411.1 Minimum efficiency Equipment schedule with type, capacity, efficiency 1411.1 Combustion htg. Indicate intermittent ignition, flue /draft damper & jacket loss 1411.1 Air- cooled chiller Provide total air and water chiller capacity 1411.2.1 Water - cooled chiller Full -load and NPLV values adjusted for any non - standard conditions 1411.4 Pkg. elec. htg.& clg. List heat pumps on schedule 1411.5 Unenclosed Heat Indicate radiant heat system and occupancy controls 1412 HVAC Controls 1412.1 Temperature zones Indicate locations on plans 1412.2 Deadband control Indicate 5 degree deadband minimum 1412.3 Humidity control Indicate humidistat 1412.4 Setback and Shutoff Indicate thermostat with 7 day program capability & required setback 1412.4.1 Dampers Indicate damper location, leakage rate, control type, & max. leakage 1412.4.2 Optimum Start Indicate optimum start controls 1412.5 Heat pump control Indicate heat pump thermostant & outdoor lockout on schedule 1412.6 Combustion heating Indicate modulating or staged control 1412.7 Balancing Indicate balancing features on plans 1412.8 Ventilation Control Indicate demand control ventilation for high - occupancy areas and labs 1412.9 Loading Dock & Garage Ventilation Indicate enclosed loading dock & parking garage ventilation system activation and control method. 1412.10 Sgl Zone VAV Ctrls Indicate VAV controls for single -zone systems 1416.3.2 System Balancing Indicate air and water system balancing requirements 1422 Thermostat interlock Indicate thermostat interlock on plans 1432.2.1 Temperature Reset Indicate temperature reset method 1413 Air / Water Economizers 1412.1 Single zone systems Indicate multiple cooling stage control capability. 1413.1 Air Econo Operation Indicate 100% capability on schedule 1413.1 Wtr Econo Operation Indicate 100% capacity at 45 degF db & 40 deg F wb 1413.2 Wtr Econo Document Indicate max. OSA condition for design clg load & equipment performance data. 1413.3 Integrated operation Indicate capability for partial cooling 1413.4 Humidification Indicate direct evap or fog atomization w/ air economizer 1413.5 Htg. Sys. Impact Indicate that system does not increase heating energy use during economizer operation 1414 Ducting Systems 1414.1 Duct sealing Indicate duct design pressures and sealing requirements 1414.1.2 Low press. duct test Indicate that low- pressure duct systems to be leak tested 1414.1.3 HP & ext. duct test Indicate that high - pressure & exterior duct systems to be leak tested 1414.2 Duct insulation Indicate R -value of insulation on duct 1415 Piping Systems 1415.1 Piping insulation Indicate R -value of insulation on piping 1415.2 Radiant Systems Indicate R -value of insulation on radiant panels Mechanical Summary Form Completed and attached. Equipment schedule with types, input/output, efficiency, cfm, hp, economizer 2009 Seattle Energy Code Compliance Forms for Nonresidential and Multifamily Residential Mechanical Permit Plans Checklist Continued MECH -CHK 2009 Seattle Energy Code Compliance Forms for Nonresidential and Multifamily Residential _ Revised February 2011 Project Address SouthCenter Mall (Date 7/28/2011 The following information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the 2009 Applicability (yes, no, na) Code Section Component Information Required Location on Plans Building Department Notes HVAC REQUIREMENTS (Section 1416), continued 1416 Completion Requirements 1416.3.2 System Balancing Indicate air and water system balancing requirements 1416.3.3 Functional Testing Provide sequence of operations and test procedures. 1416.3.4 Documentation Indicate O &M manuals, record drawings, staff training 1416.3.5 Comm. Report Indicate requirements for final commissioning report 1416.4 Compliance Chklist Submit to building official upon substantial completion. SERVICE WATER HEATING AND HEATED POOLS (Sections 1440 -1454) 1440 Service water htg. 1441 Elec. water heater Indicate R -10 insulation under tank 1442 Shut -off controls Indicate automatic shut -off of circulators or heat trace 1443 Pipe Insulation Indicate R -value of insulation on piping 1444 Pump Energy Indicate method of pump energy management (Sec 1438) 1445 Heat Recovery Indicate preheat capacity as % of peak service water demand. 1450 Heated Pools 1452 Heat Pump COP Indicate minimum COP of 4.0 1452 Heater Efficiency Indicate pool heater efficiency 1453 Pool heater controls Indicate switch and 65 degree control 1454 Pool covers Indicate vapor retardant cover 1454 Pools 90+ degrees Indicate R -12 pool cover 1455 Heat Recovery Indicate method and capacity of exhaust air temperature reduction COLD STORAGE (Sections 1460 -1465) 1460 Cold Storage 1463 Evaporators Indicate motor type and speed control 1464 Condensors Indicate condenser cooling type, design wb temp and control 1465 Compressors Indicate design minimum condensing temp and control. COMPRESSED AIR AND VACUUM PUMPS (Section 1470) 1470 Compressed Air and Vacuum 1470.1 Air compressor gnl. Indicate "no loss" water drains 1470.2 Rotary screw comp Indicate variable speed drive or other acceptable control COMMERCIAL FOOD SERVICE (Sections 1475) 1475 Commercial Food Service 1475 Food service equip. Indicate that equipment complies with energy and water efficiency criteria in Energy Star If "no" is indicated for any item in Sections 1401 -1424 or 1440 -1465 , provide explanation: • PLAN VIEW /R • TING SLIP ACTIVITY NUMBER: M11 -109 DATE: 10 -24 -11 PROJECT NAME: JAMBA JUICE SITE ADDRESS: 566. SOUTHCENTER MALL Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # X Revision # 1 After Permit Issued DEPARTMENTS: ii B it n• ision Public Works 4Prevon Structural lie n Planning Division Permit Coordinator 1 DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 10-25-11 Complete Comments: Incomplete n Not Applicable Permit Center Use Only : INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Notation: Approved with Conditions DUE DATE: 11 -22 -11 Not Approved (attach comments) n REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28-02 ERMIT COORD COPIt PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M11 -109 DATE: 08/01/11 PROJECT NAME: JAMBA JUICE SITE ADDRESS: 566 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # after Permit Issued DEPARTMENTS: ifding vision Public Works 4Vrevention Structural Planning Division Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 08/02/11 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 08/30/11 Not Approved (attach comments) ❑ DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 • PROJECT NAME: 3Conlpq r SITE ADDRESS: g(o(, SotA- Letwiw. V1ut t' • PERMIT NO: tit ` 1 Q ORIGINAL ISSUE DATE: t REVISION LOG REVISION NO. DATE RECEIVED STAFF INITI LS ISSUED DATE STAFF INITIALS 1117tht Summary of Revision: a ,� vic4 `1L_b C00 CP r Gl'►^fi( r ff 4r j SCE 0 Received by: C E7 ,5i7442r'1 REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) City of Tukwila REVISION SUBMITTAL Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Web site: http: //www.ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: O —ao- aa1 Plan ChecWPermit Number: ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # Revision # 1 after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: cj-Aivt 3 A ;n t. I Gi Project Address: Sea p. i - j►/i, 1i Contact Person:_ Summary of Revision: Phone Number: 4-80 &co el-A,15- C O c ra+1 a - c-k 44.3- LAN... 404 \ Y■e 1 .4.. ►.{ l e.6 or Cb5r i 5, 43 LAMae. /P &s. pv RISCIEWPD COYVOFTUK WILA OCT 242011 PERMIT CENTER Sheet Number(s): <----4 "Cloud" or highlight all areas of revision including date of rev io Received at the City of Tukwila Permit Center by: Entered in Permits Plus on L 0-")_1-{--1 H:\Appliations\Fonns- Applications On Line \2010 Applications \7-2010 - Revision Submittal.doc Crated: 8-13 -2004 Revised: 7 -2010 3 6 10 (E) DEMISING WALL ' / CD 3 -5/8" 20 GA. METAL STUD, TYP. FJ W -3 )ON 5/8" TYPE X GYP. BY TENANT G.C. 1 J LEASE LINE (E) NEUTRAL PIER LEASE LINE 3/4 "x1/2" BRUSHED ALUMINUM CHANNEL REVEAL BY G.C. ©® BRUSHED ALUMINUM PANELS MOUNTED ON 1/4" MDF ON 5/8" TYPE 'X' GYPBD ON METAL STUD FRAMING. BLENDER COUNTER LOW WALL, WALL THICKNESS SHOWN INCLUDES WOOD CLADDING (?'NEUTRAL PIER DETAIL —RIGHT scALE:3- 1'-0" METAL STUD FRAMING 5/8" TYPE 'X' GYP. BD. BY G.C. F MT -1 BRUSHED ALUMINUM PANEL (FI W -3 WALL TILE 1/4" MDF EXTEND (FI MT -1 )BRUSHED ALUMINUM PANEL PANEL TO CO TILE. WRAP MDF. ()CORNER DETAIL AT OPENING RILL SCALE REVISIONS No changes shall be made to the scope of Piork without prior approval of Tul mfila Building Division. - ,isions Mill require a new plan submittal L: d tray inc?ude additional plan review fees. 0 z _ ADJACENT TENANT 34, -3" LEASE LINE 31' -0" 10' 5 1 /2" 7 3' -3" NOTE: FRONT COUNTER/ PASTRY CASE/ POS COUNTER FINISHES MUST BE CONTINUOUS AND FLUSH ACROSS STOREFRONT. TOE KICK MUST BE CONTINUOUS AND FLUSH ACROSS STOREFRONT. 1 FREEZER 7' -2" COOLER 8' -0" f 4 A -805 _ ) to A - 4 119 SQ. FT. 4 6' -3" 2 A -701 _ ( 11 .,t■ ■■■ \ 2" CLR. 3' -7" .r'5/ /13' 3' -2" ;5i 23" / 23" 8' -4 1 /4" 33' -11 1 /4" INSIDE ADJACENT TENANT F!L OPY Perm!t No. m, MIAOW approval is sect to errors and ortl ;. of construction documents does not authorize try. .:Ja G' are code or i : Receipt By Data: City Of'1bkwfa BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE APPROVED NOV 0 8 2011 AT City of Tukwila BUILDING DIVISION 9' -5" gr Ligo r LINE OF SPOT CASE 3' -0 L P MALL COMMON AREA SHEET NOTES 1) PROVIDE BLOCKING AND BACKING AS DEFINED IN SPECIFICATION SECTION 06100 IN EXISTING WALLS AND NEW PARTITIONS FOR ALL CASEWORK, SHELVING, COUNTERTOPS, TOILET ACCESSORIES, AND OWNER SUPPLIED EQUIPMENT SEE 2/A -122. COORDINATE WITH SHOP DRAWINGS. 2) WHERE EXISTING INSULATION IS REMOVED OR MISSING -PATCH AND REPLACE INSULATION TO MATCH EXISTING CONDITIONS AND MAINTAIN REQUIRED : R- VALUES. 3) COORDINATE AND VERIFY ALL DIMENSIONS W/ THOSE INDICATED PRIOR TO INSTALLATION. NOTE: FRONT COUNTER / PASTRY CASE/ POS COUNTER FINISHES MUST BE CONTINUOUS AND FLUSH ACROSS STOREFRONT. TOE KICK MUST BE CONTINUOUS AND FLUSH ACROSS STOREFRONT. BLENDER COUNTER LOW WALL, WALL THICKNESS SHOWN INCLUDES WOOD CLADDING L_ 1 3/4" E LINE UNE OF POS COUNTER ABOVE- ---'-4 CONDUIT STUB UP ZONE REVISION N0.1 r II 1' -7" 16 ",1, 8 2' -9" ;e) BUILT -UP CURB -- '-LEASE UNE ALL WALL FINISHES SHALL BE SMOOTH. REMOVE OR RESURFACE TEXTURED WALL SURFACES PRIOR TO APPLYING FINISHES. 5) VERIFY ALL DIMENSIONS AND REPORT DISCREPANCIES TO THE ARCHITECT PRIOR TO FRAMING OR PENETRATING SLAB. 6) DIMENSIONS SHOWN ARE TO THE FACE OF FINISH. UNLESS OTHERWISE NOTED. 7) REFER TO A -605, DOOR SCHEDULE FOR DOOR AND FRAME TYPES. 8) ORIENT FLOOR SINKS TO ALIGN W/ ADJACENT PARTITIONS AS SHOWN. 9) REFER TO EQUIPMENT SHEETS FOR INFORMATION REGARDING EQUIPMENT AND EQUIPMENT LAYOUT. 10) MAINTAIN FIRE RESISTANCE RATING FOR ALL TENANT DEMISING WALLS :IF. PERMIT I,E_ ¢gEREDFOR: ,r0 IVIt cgh�aniical ..: lectricaf Plumbing tileas Piping C4. of Tukwila >� 3 Fell' 1.1.1 DIVISION> T ))),:"'w 4t rrrib MICHAEL R. BLACK, AIA 3100 E. RANDOL MILL ARLINGTON, TEXAS 76011 817.701.4819 WASHINGTON REGISTRATION NO.: 9205 9205 M REGISTERED AR HI CT HAEL R. BLACK TE OF WASHINGTON SHEET SYMBOLS o0 wo u6Isapswpd 3100 East Randal Mill Road CUSTOMER AREA 01 ROOM NAME AND NUMBER SEE SHEET A -701 FOR ELEVATIONS ELEVATION SYMBOL 1011 SEE SHEET A -605 DOOR INDICATOR FOR DOOR SCHEDULE V.17 A 0 NEW 3 -5/8" FULL HEIGHT WALL, REF: 1/A-801 NEW 6" FULL HEIGHT WALL, REF: 1/A-801 NEW 3 -5/8" PARTIAL HEIGHT WALL, REF: 1/A -801 NEW 3-5/8" LOW WALL (SHOWN AS 7" THICK AFTER FINISHES), REF: 1 /A -801 (E) DEMISING PARTITION: GC TO VERIFY CONDITION OF WALL AFTER DEMOLITION, PATCH, REPAIR, AND REPLACE GYP BD AS REQUIRED TO MAINTAIN FIRE RATING PER UL U465. REF: 4/A -802 RECEIVED OCT 24.2011 PERINICENTER FLOOR SINK FLOOR DRAIN oc WJ i- J Um) >z .Q Iz- o o O W "i LLI 4t W in = 0 W O co (/) Co W S PROJECT NUMBER: 110179 Issue Date 7/28/11 Drawn By BMD Appv'd BY BMD Revisions Date 0 Description By 0 A JJ 6.0 VERSION 4 -31 -08 6.0 SCALE: 1/4" = 1' -0" 1--- -1 1 2 4 Floor Plan A-121 ttft. 109 F E D C B A 1 2 3 4 5 6 7 8 9 10 SPECIFI ATIONS DIVISION 15 - MECHANICAL SECTION 15000 BASIC MECHANICAL REQUIREMENTS A. NOTE 1. DRAWINGS AND GENERAL PROVISIONS OF CONTRACT, INCLUDING GENERAL AND SUPPLEMENTARY CONDITIONS AND ALL OTHER SPECIFICATION SECTIONS, APPLY TO THIS AND THE OTHER SECTIONS OF DIVISION 15. 2. THE CONTRACTOR FOR THIS DIVISION OF WORK IS REQUIRED TO READ THE SPECIFICATIONS AND REVIEW DRAWINGS FOR ALL DIVISIONS OF WORK AND IS RESPONSIBLE FOR THE COORDINATION OF THIS WORK AND THE WORK OF HIS SUBCONTRACTORS WITH ALL DIVISIONS OF WORK. IT IS THIS CONTRACTORS RESPONSIBILITY TO PROVIDE HIS SUBCONTRACTORS WITH A COMPLETE SET OF BID DOCUMENTS. 3. THIS CONTRACTOR IS RESPONSIBLE FOR SCHEDULING THE COMPLETION AND INSPECTION OF THIS WORK TO COMPLY WITH JAMBA JUICE'S SCHEDULE AND THE PROJECT COMPLETION DATE. 4. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO SUBMITTAL OF BID TO DETERMINE CONDITIONS AFFECTING THE WORK. ANY ITEMS WHICH ARE NOT COVERED IN THE BID DOCUMENTS OR ANY PROPOSED SUBSTITUTIONS SHALL BE LISTED SEPARATELY AND QUALIFIED IN THE CONTRACTORS BID. SUBMITTAL OF BID SHALL SERVE AS EVIDENCE OF KNOWLEDGE OF EXISTING CONDITIONS AND ANY MODIFICATIONS WHICH ARE REQUIRED TO MEET THE INTENT OF THE DRAWINGS AND SPECIFICATIONS. FAILURE TO VISIT THE SITE DOES NOT RELIEVE THE CONTRACTOR OF RESPONSIBILITY IN PERFORMANCE OF HIS WORK. 5. REFER TO RESPONSIBILITY SCHEDULE FOR INFORMATION IN REGARD TO RESPONSIBILITY OF WORK OR ITEMS WHICH MAY AFFECT THE BID. B. GENERAL REQUIREMENTS 1. THIS CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIALS, EQUIPMENT, SERVICES, TOOLS, TRANSPORTATION, INCIDENTALS AND DETAILS NECESSARY TO PROVIDE A COMPLETE MECHANICAL SYSTEM AS SHOWN ON THE DRAWINGS, CALLED FOR IN THE SPECIFICATIONS, AND AS REQUIRED BY JOB CONDITIONS. ALL WORK NOT SPECIFICALLY NOTED AS BEING BY THE LANDLORD OR JAMBA JUICE SHALL BE PROVIDED BY THIS CONTRACTOR. CLOSELY COORDINATE THE ENTIRE INSTALLATION WITH THE LANDLORD AND JAMBA JUICE'S PROJECT MANAGER, AS REQUIRED. 2. THE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO SUPPLEMENT EACH OTHER AND ANY MATERIAL OR LABOR CALLED FOR IN ONE SHALL BE FURNISHED AND INSTALLED EVEN THOUGH NOT SPECIFICALLY MENTIONED IN BOTH. ANY MATERIAL OR LABOR WHICH IS NEITHER SHOWN ON THE DRAWINGS NOR CALLED FOR IN THE SPECIFICATIONS, BUT WHICH IS OBVIOUSLY NECESSARY TO COMPLETE THE WORK, AND WHICH IS USUALLY INCLUDED IN WORK OF SIMILAR CHARACTER, SHALL BE FURNISHED AND INSTALLED AS PART OF CONTRACT. 3. WHERE THE DRAWINGS OR SPECIFICATIONS CALL FOR ITEMS WHICH EXCEED CODES OR THE LANDLORD'S TENANT CRITERIA, THE CONTRACTOR IS RESPONSIBLE FOR FURNISHING AND INSTALLING THE SYSTEM WITH THE MORE STRINGENT REQUIREMENTS AS DESIGNED AND DESCRIBED ON THESE DRAWINGS, UNLESS SPECIFICALLY NOTED OTHERWISE. 4. ALL WORK IN THIS SECTION SHALL BE INSTALLED SO AS TO BE READILY ACCESSIBLE FOR OPERATING, SERVICING, MAINTAINING, AND REPAIRING. THIS CONTRACTOR IS RESPONSIBLE FOR PROVIDING SUFFICIENT SERVICE ACCESS TO ALL EQUIPMENT. 5. ALL WORK SHALL BE PERFORMED IN A NEAT PROFESSIONAL MANNER USING GOOD CONSTRUCTION PRACTICES. C. 6. UNLESS SPECIFICALLY NOTED OTHERWISE, MATERIALS, PRODUCTS, AND EQUIPMENT, INCLUDING ALL COMPONENTS THEREOF, SHALL BE NEW, UNDERWRITERS LABORATORIES LISTED AND LABELED AND SIZED IN CONFORMITY WITH REQUIREMENTS OF STATE AND LOCAL CODES, WHICHEVER IS MORE STRINGENT. 7. THIS CONTRACTOR SHALL DO ALL CUTTING, CHASING AND CHANNELING REQUIRED FOR ANY WORK UNDER THIS DIVISION. CUTTING SHALL HAVE PRIOR APPROVAL BY JAMBA JUICE'S PROJECT MANAGER AND THE LANDLORD. ALL PATCHING SHALL BE BY G.C. AND SHALL MATCH THE SURROUNDING SURFACES. 8. THE MECHANICAL CONTRACTOR SHALL MAKE ALL FINAL MECHANICAL CONNECTIONS AS REQUIRED FOR A COMPLETE AND OPERATING SYSTEM. a. THE MECHANICAL CONTRACTOR SHALL NOTIFY THE GENERAL CONTRACTOR TO CONTACT THE HVAC EQUIPMENT MANUFACTURER'S REP. FOR START UP. (PARAGRAPH OMITTED) D. CODES 1. ALL WORK SHALL CONFORM TO THE LANDLORD'S CRITERIA, THE STATE'S, COUNTY'S, CITY'S AND LOCAL CODES AND ORDINANCES, SAFETY AND HEALTH CODES, NFPA CODES, ENERGY CODES AND ALL OTHER APPLICABLE CODES AND REQUIREMENTS. THIS CONTRACTOR SHALL INQUIRE INTO AND COMPLY WITH ALL APPLICABLE CODES, ORDINANCES, AND REGULATIONS. THIS CONTRACTOR SHALL INCLUDE ANY CHANGES REQUIRED BY CODES IN THE BID AND IF THESE CHANGES ARE NOT INCLUDED IN THE BID, THEY MUST BE QUALIFIED AS A SEPARATE LINE ITEM IN THE BID. AFTER CONTRACT IS AWARDED, CHANGE ORDERS FOR INCREASED COSTS DUE TO CODE ISSUES WILL NOT BE ACCEPTED BY JAMBA JUICE. E. LICENSES. PERMITS. INSPECTIONS & FEES 1. THIS CONTRACTOR SHALL OBTAIN AND PAY FOR ALL LICENSES, PERMITS, INSPECTIONS, AND FEES REQUIRED OR RELATED TO HIS WORK. 2. FURNISH TO JAMBA JUICE'S PROJECT MANAGER ALL CERTIFICATES OF INSPECTION AND FINAL INSPECTION APPROVAL AT COMPLETION OF PROJECT. F. TRADE NAMES. MANUFACTURERS AND SHOP DRAWINGS 1. WHERE TRADE NAMES AND MANUFACTURERS ARE USED ON THE DRAWINGS OR IN THE SPECIFICATIONS, THE EXACT EQUIPMENT SHALL BE USED AS A MINIMUM FOR THE BASE BID. MANUFACTURERS CONSIDERED AS AN EQUAL OR BETTER IN ALL ASPECTS TO THAT SPECIFIED WILL BE SUBJECT TO APPROVAL IN WRITING BY JAMBA JUICE'S PROJECT MANAGER THROUGH SHOP DRAWING SUBMITTAL PROCESS FOR ACCEPTANCE PRIOR TO INSTALLATION. THE USE OF ANY UNATHORIZED EQUIPMENT SHALL BE REPLACED AT THE CONTRACTOR'S EXPENSE. 2. GENERAL CONTRACTOR SHALL SUBMIT ONLY SUBSTITUTION REQUESTS TO JAMBA JUICE'S PROJECT MANAGER FOR APPROVAL. SUBMISSIONS SHALL BE MADE EARLY ENOUGH IN PROJECT TO ALLOW FOUR (4) WORKING DAYS FOR JAMBA JUICE'S PROJECT MANAGER'S REVIEW WITHOUT CAUSING DELAYS OR CONFLICTS TO THE JOB'S PROGRESS. SUBMITTALS SHALL BEAR THE STAMP AND /OR THE SIGNATURE OF THE GENERAL CONTRACTOR AND THE SUB - CONTRACTOR SHOWING THAT HE HAS REVIEWED AND CONFIRMED THAT THE SUBMITTALS ARE IN CONFORMANCE WITH THE CONTRACT DRAWINGS AND SPECIFICATIONS OR INDICATE WHERE EXCEPTIONS HAVE BEEN TAKEN. G. GUARANTEE 1. THE EQUIPMENT MANUFACTURER SHALL GUARANTEE AND PROVIDE A 12 MONTH GUARANTEE TO JAMBA JUICE FROM THE DATE OF ACCEPTANCE. THIS CONTRACTOR SHALL WARRANTY THE INSTALLATION OF THIS EQUIPMENT AND WILL BE RESPONSIBLE FOR ANY DAMAGE AND /OR MALFUNCTION CAUSED BY THE INSTALLATION. THIS CONTRACTOR SHALL NOT BEAR ADDITIONAL WARRANTIES BEYOND A COMPLETE WORKING SYSTEM. H. RECORD DRAWINGS 1. THIS CONTRACTOR SHALL MAINTAIN ONE SET OF DRAWINGS ON THE JOB SITE UPDATED WEEKLY TO RECORD ALL DEVIATIONS FROM CONTRACT DRAWINGS, SUCH AS: a. LOCATION OF CONCEALED PIPING VALVES AND DUCTS. b. REVISIONS, ADDENDUMS, AND CHANGE ORDERS. c. SIGNIFICANT DEVIATIONS MADE NECESSARY BY FIELD CONDITIONS, APPROVED EQUIPMENT SUBSTITUTIONS, AND CONTRACTOR'S COORDINATION WITH OTHER TRADES. 2. AT COMPLETION OF THE PROJECT AND BEFORE FINAL APPROVAL, THIS CONTRACTOR SHALL MAKE ANY FINAL CORRECTIONS TO DRAWINGS AND CERTIFY THE ACCURACY OF EACH PRINT BY SIGNATURE THEREON. FAILURE TO KEEP THESE RECORDS WILL ALLOW JAMBA JUICE TO DIRECT THE GENERAL CONTRACTOR TO PROVIDE THESE RECORDS AT HIS EXPENSE PRIOR TO FINAL PAYMENT. J. K. L. M. N. DISCREPANCIES IN DOCUMENTS 1. DRAWINGS (PLANS, SPECIFICATIONS, AND DETAILS) ARE DIAGRAMMATIC AND INDICATE THE GENERAL LOCATION AND INTENT OF THE MECHANICAL SYSTEMS. WHERE DRAWINGS, EXISTING SITE CONDITIONS, SPECIFICATIONS OR OTHER TRADES CONFLICT OR ARE UNCLEAR, ADVISE THE GENERAL CONTRACTOR IN WRITING, PRIOR TO SUBMITTAL OF BID. THE GENERAL CONTRACTOR IS RESPONSIBLE TO ADVISE JAMBA JUICE'S PROJECT MANAGER, IN WRITING, OF VARIATIONS TO CONTRACT DOCUMENTS PRIOR TO SUBMISSION OF BID. OTHERWISE, JAMBA JUICE'S PROJECT MANAGER'S INTERPRETATION OF CONTRACT DOCUMENTS OR CONDITIONS SHALL BE FINAL WITH NO ADDITIONAL COMPENSATION PERMITTED. PHASING REQUIREMENTS 1. THIS CONTRACTOR IS TO INCLUDE IN HIS BID ALL NECESSARY SERVICE REQUIRED TO KEEP THE OPERATING PHASE OF THE STORE'S HVAC, PLUMBING AND SPRINKLER SERVICE IN OPERATION. CONTRACTOR MUST SCHEDULE IN WRITING WITH JAMBA JUICE'S PROJECT MANAGER AND THE LANDLORD ONE WEEK PRIOR TO ANY SHUT DOWN OF THE HVAC, PLUMBING OR FIRE PROTECTION SYSTEMS. DEMOLITION 1. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION OF THE DEMOLITION OF EXISTING WORK AND THE DEMOLITION PROVIDED BY THE GENERAL CONTRACTOR. COORDINATE WITH THE GENERAL CONTRACTOR ANY EXISTING EQUIPMENT REQUIRED TO BE LEFT INTACT. 2. THIS CONTRACTOR SHALL INCLUDE, AND WILL BE HELD RESPONSIBLE FOR, THE REMOVAL OF ALL EXISTING HVAC UNITS, HYDRONIC PIPING, REFRIGERANT RECAPTURE, EXHAUST FANS, ETC. AND ASSOCIATED ROOF CURBS NOT TO BE REUSED ON THIS PROJECT, UNLESS SPECIFICALLY NOTED OTHERWISE. CONTRACTOR MUST VERIFY WITH THE LANDLORD ALL PRESUMED ABANDONED EQUIPMENT, PIPES, DUCTWORK, AND EQUIPMENT PRIOR TO REMOVAL. ROOF CURBS SHALL BE REMOVED AND THE ROOF PATCHED. ALL EXTRANEOUS ITEMS IN THE SPACE OR ON THE ROOF NOT APPLICABLE TO THE NEW WORK MUST BE REMOVED AND ROOF /WALL / FLOOOR PATCHED /REPAIRED TO MATCH EXISTING STRUCTURE. EXISTING ABANDONED PIPES, DUCTS, OR EQUIPMENT IN THE FLOOR, EMBEDDED IN CONCRETE OR OTHERWISE INACCESSIBLE ARE TO BE CUT OFF AND SEALED BELOW OR WITHIN FLOOR OR WALL LEVEL WHEN THEY ARE NOT TO BE REUSED IN THIS PROJECT. IF REQUIRED BY LANDLORD OR CODES, ABANDONED PIPING AND /OR DUCTWORK MUST BE REMOVED TO POINT OF ORIGIN. CONFIRM THE EXTENT OF DEMOLITION PRIOR TO BID AND INCLUDE IN BID PROPOSAL. SLEEVES 1. THIS CONTRACTOR SHALL PROVIDE SLEEVES TO PROTECT EQUIPMENT OR FACILITIES IN THE INSTALLATION. EACH SLEEVE SHALL EXTEND THROUGH IT'S RESPECTIVE FLOOR, WALL OR PARTITION AND SHALL BE CUT FLUSH WITH EACH SURFACE EXCEPT SLEEVES THAT PENETRATE THE FLOOR, WHICH SHALL EXTEND 2" ABOVE THE FLOOR. CONTRACTOR MUST COORDINATE THROUGH THE LANDLORD ANY CORE DRILLING OR CUTTING OF OPENINGS IN MASONRY FLOORS OR WALLS. 2. ALL SLEEVES AND OPENINGS THROUGH FIRE RATED WALLS AND /OR FLOORS SHALL BE FIRE SEALED WITH CALCIUM SILICATE, SILICONE "RTV" FOAM, "3M" FIRE RATED SEALANTS OR EQUAL, SO AS TO RETAIN THEIR FIRE RATING. 3. SLEEVES IN BEARING AND MASONRY WALLS, FLOORS, AND PARTITIONS SHALL BE STANDARD WEIGHT STEEL PIPE FINISHED WITH SMOOTH EDGES. FOR OTHER THAN MASONRY PARTITIONS, THROUGH SUSPENDED CEILINGS, OR FOR CONCEALED VERTICAL PIPING, SLEEVES SHALL BE N0. 22 U.S.G. GALVANIZED STEEL MINIMUM. HANGERS 1. HANGERS SHALL INCLUDE ALL MISCELLANEOUS STEEL SUCH AS ANGLE IRON, BANDS, C- CLAMPS WITH RETAINING CLIPS, CHANNELS, HANGER RODS, ETC., NECESSARY FOR THE INSTALLATION OF WORK. 2. HANGERS SHALL BE FASTENED TO BUILDING STEEL, CONCRETE, OR MASONRY, BUT , NOT TO PIPING. HANGING FROM METAL DECK IS NOT PERMITTED. HANGERS MUST BE ATTACHED TO UPPER CHORD OF BAR JOIST. WHERE INTERFERENCES OCCUR, AND IN ORDER TO SUPPORT DUCTWORK OR PIPING, THE CONTRACTOR MUST INSTALL TRAPEZE TYPE HANGERS OR SUPPORTS WHICH SHALL BE LOCATED WHERE THEY DO NOT INTERFERE WITH ACCESS TO FIRE DAMPERS, VALVES, AND OTHER EQUIPMENT. HANGER TYPES AND INSTALLATION METHODS ARE ALSO SUBJECT TO LANDLORD CRITERIA. 3. HANGERS FOR ALL INSULATED PIPING SHALL BE SIZED AND INSTALLED FOR THE OUTER DIAMETER OF INSULATION. INSTALL 6" LONG SPLIT CIRCLE GALVANIZED SADDLE BETWEEN THE HANGER AND THE PIPE INSULATION. 4. HANGERS AND PIPING OF DISSIMILAR METALS SHALL BE DIELECTRICALLY SEPARATED. FINAL HVAC INSPECTIONS 1. ASIDE FROM NORMAL INTERIM INSPECTIONS OF WORK IN PLACE, JAMBA JUICE SHALL HAVE AN INDEPENDENT HVAC CONTRACTOR INSPECT THE FINISHED HVAC INSTALLATION UPON COMPLETION FOR COMPLIANCE WITH THE PLANS, SPECIFICATIONS AND CODES. THE INSTALLING CONTRACTOR WILL BE RESPONSIBLE TO BRING ALL ITEMS REPORTED BY THE INDEPENDENT HVAC CONTRACTOR UP TO PLANS AND SPECIFICATION REQUIREMENTS. END OF SECTION 15000 FILE COPY Permit No. IO' PlPn review approval is subject to errors and omissions. Approval of construction documents does not authorize l T; vv o!ation of any adopted code or ordinance. Receipt oti approved Field Copy and conditions is acknowledged: By. Date: Pp/00P City Of Tukwila BUILDING DIVISION REVISIONS Changes shall be made to the scope r' Ivork vtrithout prior approval of : Fkwila Building Division. c.r^� will require a new plan submittal J I;p:,:ude additional plan revie v fees. SE iAi } { E PERMIT REQUIRED FOR: 0 Mechanical lectrical iumbing collOrg Pip ,ng REVIEWED FOR CODE COMPLIANCE APPROVED AUG 19 2011 City of Tukwila BUILDING DIVISION SECTION 15500 HEATING. VENTILATION AND AIR CONDITIONING A. SCOPE OF WORK 1. THIS CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, EQUIPMENT, SERVICES, TOOLS, TRANSPORTATION AND FACILITIES NECESSARY FOR, REASONABLY IMPLIED AND INCIDENTAL TO THE FURNISHING, INSTALLATION, COMPLETION AND TESTING OF ALL THE WORK FOR THE HVAC SYSTEMS AS SHOWN ON THE DRAWINGS, CALLED FOR IN THE SPECIFICATIONS, AND AS REQUIRED BY JOB CONDITIONS, TO INCLUDE, BUT NOT BE LIMITED TO THE FOLLOWING: B. C. D. a. b. c. d. e. HVAC UNITS, ALL RELATED EQUIPMENT AND ACCESSORIES (UNLESS NOTED OTHERWISE). DUCTWORK, FITTINGS, DAMPERS, AND INSULATION. HYDRONIC PIPING. (AS APPLICABLE, REFER TO PLANS). REFRIGERANT PIPING (AS APPLICABLE, REFER TO PLANS). CURBS, ROOFING, AND STEEL FRAMING FOR SUPPORT (AS APPLICABLE, REFER TO PLANS). f. TESTING, ADJUSTING, AND BALANCING. g. KEEPING A RECORD SET AND PREPARE AS -BUILT DRAWINGS. 2. BEFORE STARTING WORK, THIS CONTRACTOR SHALL VISIT THE JOBSITE AND EXAMINE THE ARCHITECTURAL, STRUCTURAL, MECHANICAL AND ELECTRICAL PLANS AND SPECIFICATIONS TO SEQUENCE, COORDINATE, AND INTEGRATE THE VARIOUS ELEMENTS OF THE HVAC SYSTEM, MATERIALS, AND EQUIPMENT WITH OTHER CONTRACTORS TO AVOID INTERFERENCES AND CONFRONTATIONS. 3. RELOCATION OF EXISTING DUCT MAINS OR BRANCHES TO MEET STORE DESIGN CRITERIA MUST BE INCLUDED IN BID PROPOSAL. HVAC EQUIPMENT 1. PRIMARY HEATING AND AIR CONDITIONING UNITS ARE TO BE FURNISHED PER THE RESPONSIBILITY SCHEDULE, UNLESS NOTED OTHERWISE. REFER TO PLANS FOR REQUIREMENTS. ALL EQUIPMENT SHALL INCLUDE A FIVE (5) YEAR COMPRESSOR AND TEN (10) YEAR HEAT EXCHANGER WARRANTY. 2. ALL EQUIPMENT SHALL BE COMPLETE IN EVERY RESPECT WITH ALL DEVICES AND ACCESSORIES PROVIDED TO MEET THE DESIGN INTENT AND OPERATION OF THE SYSTEMS SHOWN ON THE DRAWINGS AND SPECIFIED HEREIN. 3. EQUIPMENT SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. 4. SECONDARY DRAIN PANS ARE REQUIRED TO BE INSTALLED BENEATH ALL INDOOR AIR CONDITIONING EQUIPMENT WITH THE EXCEPTION OF VAV BOXES. SECONDARY PANS ARE TO CAPTURE POTENTIAL LEAKS FROM THE ENTIRE UNIT. PROVIDE CONDENSATE PUMPS AS REQUIRED. CONDENSATE SHALL BE DIRECTED TO MOP SINK OR AS SPECIFIED ON PLANS. (PARAGRAPH OMITTED) METAL DUCTWORK - NO FIBERGLASS DUCT ALLOWED 1. NO DUCTWORK SHALL BE FABRICATED PRIOR TO JOB SITE VISIT AND APPROVAL BY THE GENERAL CONTRACTOR. A SKETCH MUST BE SUBMITTED INDICATING DEVIATIONS FROM DESIGN AND MUST BE APPROVED BY JAMBA JUICE'S PROJECT MANAGER PRIOR TO FABRICATION OR INSTALLATION. 2. EXCEPT AS OTHERWISE INDICATED, FABRICATE AND INSTALL RECTANGULAR AND ROUND DUCTWORK WITH GALVANIZED STEEL, IN ACCORDANCE WITH SMACNA "HVAC DUCT CONSTRUCTION STANDARDS" OF THE LATEST EDITION. WHERE OTHER CODES ARE ENFORCED, (IE. UMC, BOCA, ETC.) USE THE MOST STRINGENT CODE FOR DUCT CONSTRUCTION STANDARDS. 3. EXCEPT WHERE OTHERWISE INDICATED, CONSTRUCT DUCT SYSTEMS TO THE FOLLOWING PRESSURE CLASSIFICATIONS: SUPPLY DUCTS: 2" W.G., POSITIVE RETURN AND EXHAUST DUCTS: 2" W.G., NEGATIVE EXCEPT WHERE OTHERWISE INDICATED, USE DUCT SEALANTS OF THE FOLLOWING PRESSURE CLASSIFICATIONS: SUPPLY DUCTS: CLASS B - 3" W.G. RETURN AND EXHAUST DUCTS: CLASS C - 2" W.G. IN ACCORDANCE WITH THESE CONSTRUCTION AND SEALANT PRESSURE CLASSIFICATIONS, MAXIMUM DUCT AIR LEAKAGE WILL NOT EXCEED 5% AS REQUIRED FOR FINAL AIR BALANCE APPROVAL. 4. ROUND DUCTWORK SHALL BE GALVANIZED STEEL WITH SPIRAL LOCKSEAM CONSTRUCTION FOR ALL SIZES 14" DIAMETER AND LARGER. ROUND DUCTWORK SIZES 13" DIAMETER AND SMALLER MAY BE SNAP -LOCK CONSTRUCTION. ALL SNAP -LOCK SEAMS SHALL BE SEALED AS DESCRIBED IN THESE SPECIFICATIONS. ROUND FITTINGS SHALL BE GALVANIZED STEEL WITH SPOT WELDED ' AND BONDED CONSTRUCTION. 5. ROUND SPIRAL GALVANIZED STEEL DUCTWORK MAY BE USED IN PLACE OF RECTANGULAR DUCTWORK IN HORIZONTAL APPLICATION WHEN ABOVE CEILING CLEARANCES PERMITS AND EQUIVALENT FREE AREA IS MAINTAINED. ONCE A TRANSITION IN THE DIRECTION OF THE AIRFLOW TO SPIRAL HAS BEEN DONE, DUCT WILL NOT BE ALLOWED TO REVERT TO RECTANGULAR. WHERE ROUND DUCT SUBSTITUTION WILL TAKE PLACE, SUBMIT A SKETCH AND CHART SHOWING EQUIVALENT ROUND CONVERSIONS OF RECTANGULAR DUCTWORK TO JAMBA JUICE'S PROJECT MANAGER FOR APPROVAL PRIOR TO FABRICATION OR INSTALLATION. 6. INSTALL FACTORY MANUFACTURED DOUBLE THICKNESS TURNING VANES IN ALL RIGHT ANGLE ELBOWS IN MAIN DUCT PER LATEST EDITION OF SMACNA. 7. INSTALL RIGID ROUND AND RECTANGULAR METAL DUCT WITH SUPPORT SYSTEMS INDICATED IN SMACNA STANDARDS. SUPPORT HORIZONTAL DUCTS WITHIN 2 FEET OF EACH ELBOW AND WITHIN 4 FEET OF EACH BRANCH INTERSECTION USING DOUBLE STRAP HANGERS ON EACH SIDE OF FITTING. SUPPORT VERTICAL DUCTS AT A MAXIMUM INTERVAL OF 16 FEET AND AT EACH FLOOR. NO WOOD SHALL BE USED TO SUPPORT OR BRACE DUCTS. PROVIDE SWAY AND SEISMIC BRACING AS REQUIRED BY STATE AND LOCAL CODES OR BY LANDLORD. 8. WHERE DUCTS PASS THROUGH ROOFS AND FLOORS, PROVIDE A MINIMUM 1-1/2" x 1-1/2" x 1 /8" STEEL ANGLE FRAME AT EACH SIDE OF OPENING. THE ANNULAR SPACE BETWEEN DUCT AND ANGLE FRAMES SHALL BE CAULKED WITH SILICONE SEALANT OR FIREPROOFED AS REQUIRED BY ASSEMBLY FIRE RATING. 9. ALL JOINTS AND SEAMS SHALL BE SEALED WITH 2" WIDE, GLASSFIBER- FABRIC REINFORCED TAPE. JOINTS ALSO SHALL BE RIVETED OR CONNECTED WITH SHEET METAL SCREWS. LIQUID SEALANTS BY UNITED MCGILL CORP., DOW CORNING, MIRACLE ADHESIVES AND SUREBOND INC. WILL BE ACCEPTED IN LIEU OF TAPE. 10. SOFT ELASTOMER BUTYL GASKET WITH ADHESIVE BACKING SHALL BE USED TO SEAL FLANGED JOINTS. 11. DUCT TRANSITIONS SHALL NOT EXCEED 30 DEGREES SLOPE EXCEPT AS SPECIFICALLY NOTED OTHERWISE. D. METAL DUCTWORK (CONTINUED) 12. PROVIDE ACCESS TO ALL MOTORIZED DAMPERS, FIRE DAMPERS, CONTROLS, AND OTHER ITEMS IN DUCTWORK THAT REQUIRE SERVICE OR INSPECTION. IF THE ACCESS PANEL LOCATION IS EXPOSED TO THE SALES AREA, IT MUST BE APPROVED BY JAMBA JUICE'S PROJECT MANAGER PRIOR TO INSTALLATION. IN HARD CEILINGS, LAY -IN SUPPLY AND RETURN AIR DIFFUSERS, GRILLES AND REGISTERS WITH PLASTER FRAMES MAY BE USED AS ACCESS LOCATIONS WHEN WITHIN 3' -0" OF DEVICE. 13. ALL DUCTWORK SHALL BE INSTALLED WITH INSIDE CLEAR DIMENSIONS AS NOTED ON DRAWINGS. WHERE DUCTWORK SIZE IS LARGER THAN CONNECTED DEVICE (IE. VAV BOX, DIFFUSER, REGISTER) SMOOTH DUCT TRANSITIONS ARE TO TAKE PLACE JUST PRIOR TO DEVICE CONNECTION. EDIUM PRESSURE DUCT 1 WH ' IUCTWORK IS SPECIFICALLY NOTED AS MEDIUM PRESSURE, IT S CONSTRUC ACCORDANCE WITH SMACNA STANDARDS FOR OF 4 INCHES WAT = •LUMN MINIMUM OR GREATER AS 2. ALL GAUGES AND REINFORCE SSURE RATING ED BY LANDLORD. MUST MEET THE LATEST EDITION OF SMACNA STANDARDS FOR MEDIUM PRESSURE 3. CONNECTIONS TO THE LAN WITH "LO -LOSS" S 4. ALL OT F. G. H. J. K. L. WITH THE LANDLORD'S CRITERIA. S MEDIUM PRES DUCTWORK SHALL BE MADE TEE TAPS OR AS OTHERWISE R ED BY THE LANDLORD. TEMS FROM METAL DUCTWORK SPECIFICATION SECTION TO THIS ON, WITH THE EXCEPTION THAT ALL MEDIUM PRESSURE DUCTWORK MU WRAPPED INSULATION, NOT LINED. 11 r t0 VIBRATION ISOLATION DEVICES 1. SPRING VIBRATION ISOLATION DEVICES SHALL BE FURNISHED AND INSTALLED IN ALL SUPPORTS BETWEEN VIBRATING EQUIPMENT (FANS, AIR HANDLERS, ETC.) AND STRUCTURE. ISOLATORS TO BE SIZED ACCORDING TO LOAD WITH A MIN. 1" DEFLECTION. VIBRATING EQUIPMENT HUNG FROM STRUCTURE SHALL BE ISOLATED WITH RUBBER AND SPRING DEVICES. VIBRATING EQUIPMENT SUPPORTED FROM FLOOR OR DECK SHALL BE ISOLATED WITH HOUSED SPRING MOUNT DEVICES. 2. EXAMINE DEAD LOAD AND OPERATING LOAD CONDITIONS WHEN SELECTING DEVICES. ADJUST FOR PROPER ALIGNMENT AND LOADING. AVOID "GROUNDING" THE ISOLATOR. 3. CHECK HANGER ROD SIZE FOR ALLOWABLE LOADS AT THE ISOLATING DEVICE AND AT THE UPPER AND LOWER ATTACHMENTS TO STRUCTURES, DUCTS, EQUIPMENT, ETC. 4. CONSULT MANUFACTURER FOR APPLICATION DATA. FLEXIBLE CONNECTIONS 1. FLEXIBLE COLLARS SHALL BE FURNISHED AND INSTALLED IN ALL CONNECTIONS BETWEEN VIBRATING EQUIPMENT (FANS, AIR HANDLERS, ETC.) AND DUCTS OR CASINGS. ALSO, FURNISH AND INSTALL FLEXIBLE CONNECTIONS WHERE DUCTS CROSS BUILDING EXPANSION JOINTS. 2. FLEXIBLE CONNECTIONS SHALL BE CONSTRUCTED OF NEOPRENE - COATED FLAMEPROOF FABRIC. PROVIDE ADEQUATE JOINT FLEXIBILITY TO ALLOW FOR MOVEMENT AND PREVENT THE TRANSMISSION OF VIBRATION. FLEXIBLE AIR DUCT 1. FLEXIBLE AIR DUCT SHALL BE 1" INSULATED CLASS 1, UL LISTED AND RATED FOR THE OPERATING _PRESSURE OF THE SYSTEM. DUCT CONSTRUCTION MATERIAL (PLASTIC, CLOTH, ALUMINUM) MUST ADHERE TO LOCAL CODES AND LANDLORD'S REQUIREMENTS AND BE INCLUDED AS SUCH IN THE BID. 2. FLEXIBLE AIR DUCT SHALL BE ATTACHED PER DETAILS ON THE DRAWINGS. FLEXIBLE AIR DUCT MAY ONLY BE USED IN VERTICAL APPLICATIONS. 3. FLEXIBLE DUCT SHALL NOT EXTEND OVER 5' -O" IN LENGTH AT ANY ONE LOCATION. SUPPLY AIR TAKE -OFF FITTINGS 1. FURNISH AND INSTALL CONICAL, TAPERED OR 45 DEGREE SADDLE TAKE -OFFS FROM MAIN DUCTWORK TO ROUND BRANCHES. INSTALLATION SHALL BE PER SMACNA LATEST EDITION. DAMPERS 1. WHERE DESIGNATED, FURNISH AND INSTALL MANUAL LOCKING QUADRANT VOLUME CONTROL DAMPERS WITH HANDLE OPERATORS AS SHOWN ON PLANS TO FACILITATE AIR BALANCING. DURODYNE MODEL NO: K SERIES QUADRANT. 2. OPERATING HANDLES ON ALL DAMPERS SHALL BE TAGGED WITH A MINIMUM 18" LONG ORANGE MARKER TAPE. 3. WHERE ACCESS TO BALANCING DAMPER IS RESTRICTED, A REMOTE DEVICE, MANUALLY OPERATED SHALL BE USED. UNITS SHALL BE ORDERED THREE WEEKS BEFORE INSTALLATION TO ALLOW FOR DELIVERY LEAD TIME. FIRE /FIRE SMOKE DAMPERS 1. FURNISH AND INSTALL PRIMARY FIRE DAMPERS WHERE INDICATED OR REQUIRED BY CODES. DAMPERS SHALL BE DESIGNED FOR HORIZONTAL OR VERTICAL FLOW OF AIR AS REQUIRED. FIRE DAMPERS SHALL BE UL LABELED AND MEET ALL CODE REQUIREMENTS. 2. FIRE DAMPERS SHALL HAVE THE BLADES OUT OF THE AIRSTREAM AND A 165 DEGREE F FUSIBLE LINK, TYPE B, AS MINIMUM. FURNISH AND INSTALL ACCESS DOORS AS NECESSARY. 3. FURNISH AND INSTALL ALL NECESSARY FRAMING AND SLEEVES FOR DAMPER MOUNTING PER UL AND CODE REQUIREMENTS. 4. FIRE SMOKE DAMPERS SHALL BE FURNISHED AND INSTALLED WITH ELECTRIC POWERED MECHANISM. COORDINATE WITH ELECTRICAL CONTRACTOR FOR POWER REQUIREMENTS. DUCTWORK INSULATION 1. FURNISH AND INSTALL INSULATION PRODUCTS IN ACCORDANCE WITH MANUFACTURER'S WRITTEN INSTRUCTIONS, AND IN ACCORDANCE WITH RECOGNIZED INDUSTRY PRACTICES. INSULATION MUST COMPLY WITH NFPA 90A. 2. DUCT SIZES SHOWN ON DRAWINGS ARE INSIDE CLEAR DIMENSIONS. ALL SUPPLY AND RETURN AIR RECTANGULAR DUCTWORK SHALL BE INTERNALLY INSULATED WITH 1" THICK, 1 -1/2 LB. DENSITY LINE (C =0.28 © 75 DEGREE F). WHEN A COMPLETE DUCTED RETURN AIR SYSTEM IS INDICATED ON THE DRAWINGS, ONLY THE 15' -0" OF THE RETURN AIR DUCT CLOSEST TO THE AIR HANDLING UNIT IS TO BE INSULATED. LINER IS TO HAVE A COATED SURFACE EXPOSED TO AIRSTREAM TO PREVENT EROSION. APPLY ADHESIVES AND MECHANICAL FASTENERS AS RECOMMENDED BY SMACNA AND THE MANUFACTURER TO PREVENT LINER SEPARATION FROM THE DUCT. ALL TRANSVERSE EDGES TO BE COATED WITH ADHESIVE. 3. DUCTWORK SHALL BE EXTERNALLY INSULATED WITH A MINIMUM OF 1 1/2" THICK, 1# DENSITY (R =5.6) DUCT WRAP WITH VAPOR BARRIER. VAPOR BARRIER IS TO BE MAINTAINED THROUGHOUT DUCT SYSTEM, EXCEPT LINED DUCTWORK SPECIFIED ELSEWHERE AND EXHAUST DUCTWORK. ALL JOINTS MUST BE OVERLAPPED AND TUCKED SO THAT NO INSULATION FIBER IS VISIBLE. EXTEND DUCTWORK INSULATION WITHOUT INTERRUPTION THROUGH WALLS, FLOORS AND OTHER PENETRATIONS. 4. ALL INSULATION SHALL HAVE A FLAME SPREAD RATING OF NOT MORE THAN 25 AND A SMOKE DEVELOPED RATING OF NO HIGHER THAT 50 WHEN TESTED IN ACCORDANCE WITH ASTM C 411, OR AS REQUIRED BY LOCAL CODES. DR DANIEL A. REEVES, P.E. 3100 E. Rondo! Mill Rd Arlington, •IX 76011 (817)633 -4200 FAX (817)633 -4153 Washington License #44016 solo 00 woru6lsepswpd 3100 East Randal Mill Road N- (,) U u. Co 00 I-I„J r d± ?' Z Q 0 IA a ci)O Nal m 2 U W aWocol- n _ u. ci) w H co V) ffi WLr) PROJECT NUMBER: Issue Date Drawn By 7/28/11 AQ Appv'd By DAR Revisions Date Description By A A A A crrvREfiu 1 LA AUG 012011 PERMIT CENTER J6.0 VERSION 4 -31 -08 6.0.0 Mechanical Specs. M -007 of Tukwila ,';;DfVISION SPECIFICATIONS (CONTINUED) CO \STRUCTIO \ NOTES GE \ERAL NOTES CONTINUED FROM SHEET M -001 SECTION 15500 HEATING. VENTILATION AND AIR CONDITIONING M. HYDRONIC PIPING 1. FURNISH AND INSTALL A COMPLETE HYDRONIC PIPING SYSTEM IF APPLICABLE. REFER TO PLANS TO DETERMINE IF A HYDRONIC SYSTEM IS REQUIRED. 2. PIPING a. HYDRONIC PIPING FOR CHILLED WATER, CONDENSER WATER AND /OR HEATING WATER SHALL BE ASTM A -53, SCHEDULE 40, ERW, BLACK STEEL PIPE WITH ENDS. INSTALL STEEL PIPE WITH WELDED JOINTS WHERE PIPE IS 2-1/2 INCH LARGER. INSTALL STEEL PIPE WITH THREADED JOINTS AND FITTINGS. INSTALL "K" COPPER PIPE FOR 2 INCH AND SMALLER PIPE. PROVIDE DIELECTRIC UNI BETWEEN DISSIMILAR METALS. ALL PIPING SHALL BE IN STRICT CONFORMAN ASTM, ASA, AND LANDLORD'S REQUIREMENTS, WHICHEVER IS MOST STRING NIONS OR FLANGES MUST BE USED AT EQUIPMENT CONNECTIONS WHER REMOVAL MAY BE REQUIRED. P AIN AND TYPE NS E WITH NT. SERVICE b. ALA PIPING AND EQUIPMENT SHALL BE PRESSURE TESTED WITHOUT LEA AGE AT A MIN UM PRESSURE OF 125 PSI. c. ALL YDRONIC PIPING AND EQUIPMENT CONNECTED TO THE HVAC PI' NG SYSTEM SHAL BE CLEANED AND FLUSHED. REMOVE, CLEAN, AND REPLACE :TRAINER SCREE S. FILL TENANT'S SYSTEM WITH DOMESTIC WATER AND VENT ALL PIPING AND L UIPMENT PRIOR TO CONNECTION TO THE LANDLORD'S SY EM. CONTRACTOR SHALL NOT FILL TENANT'S SYSTEM WITH WATER FROM THE LANDLORD'S SYSTEM UNLESS SPECIFICALLY INSTRUCTED TO DO :0 FROM THE LANDLORD FIELD REPRESENTATIVE. ANY RUNS THRU A CHASE OR SHAFT WILL BE DONE WITH FEWEST JOINTS POSSIBLE USING THE LONGEST LEN TH OF HARD COPPER PIP AVAILABLE. SHOULD A JOINT BE REQUIRED, CO TRACTOR SHALL MAKE ALL E ORTS TO KEEP THE JOINTS IN ACCESSIBLE AR r AS. d. PRIOR TO CO ECTION TO THE LANDLORD'S SYSTEM, CONTACTOR SHALL OBTAIN WRITTEN CONFI "MATION FROM THE LANDLORD'S FIELD REPRESENTATIVE, THAT ALL TESTING, FLUSHI G, AND PROPER FILLING OF THE TENANT S SYSTEM HAS BEEN COMPLETED IN ArCORDANCE TO THE LANDLORD'S REQUIREMENTS AND THAT THE TENANT'S SYSTEM IS READY TO BE CONNECTED TO TH LANDLORD'S SYSTEM. 3. VALVES a. GATE VALVES, 2 -IN ASTM B 62 CAST BR RENEWABLE SOLID BR RE- PACKABLE UNDER SUBSTITUTION. b. AND SMALLER: CLASS 150, B NZE WITH THREADED OR SOLD ZE WEDGE DISC, RISING ST RESSURE. BALL VALVES 'E GATE VALVES, 2-1/2 INC RENEWABLE BRONZE SEAT AND RE- PACKABLE UNDER c. SWING CHECK VALVES, 2 -IN AND CAP CONFORMING TO A RENEWABLE BRONZE DISC, AN d. DY AND UNION BONNET OF R ENDS, INTEGRAL SEAT, SCREWED BONNET AND ACCEPTED AS AN EQUAL AND LARGER: CLAS 125 CAST IRON BODY, AND SOLID WEDGE RISC, RISING STEM, FLANGED ENDS, PRESSURE. H AND SMALLE'. CLASS 150. CAST BRONZE BODY TM B 62 WITH HORIZONTAL SWING, Y- PATTERN, HAVING THREADED OR SOLDERED ENDS. SWING CHECK VALVE, 2-1/2 IN . H AND L RGER: CLASS 125 CAST IRON BODY AND BOLTED CAP, HORIZONTAL 'WING, RENEWABLE BRONZE DISC, FLANGED ENDS AND CAPABLE OF BEING REFITTE) WHIL THE VALVE REMAINS IN THE LINE. e. COMBINATION BALANCING AND SH T -Or F VALVES: BELL & GOSSETT CIRCUIT • SETTER WITH LOCKING SET POINT. RCUIT SETTER BALANCE WHEEL MUST BE INCLUDED WITH 0 & M MANUAL. TAt 9 OR GRISWOLD ARE CONSIDERED AS EQUAL. 4. PIPING SPECIALTIES a. PRESSURE /TEMPERATURE TEST PL TO RECEIVE EITHER A TEMPERATU AND CAPS SHALL BE BRASS WIT 0 TO 200 DEGREES F. GS \PETE'S PLUG) - 1/4 INCH NPT FITTINGS E OR PRESSURE PROBE, 1/8 INCH O.D. FITTING VALV CORE OF NORDEL, RATED AT 400 PSIG, b. STRAINERS - "Y" PATTERN STAINERS, 12 PSIG, CAST IRON BODY WITH FOR 2 INCHES AND SMALLER, PERFORATED STAINLESS STEE SCREEN, TH ADED , FLANGED FOR 2-1/2 INCHE AND LARGER. CREEN OPENING SIZE AT 0.033 INCH FOR HEATING AND 1/8 INC FOR CHILLED OR CONDENSER WATER. PROVIDE WITH BLOWDOWN VALVE WITH HO E END FITTING. 5. INSULATION a. ALL HYDRONIC PIPING F R CHILLED WATER AND /OR HEATING WATER (NOT INCLUDING CONDENSER ATER UNLESS SPECIFICALLY NOTED OTHERWISE), VALVES, FITTINGS, AND ACCESSIRIES SHALL BE INSULATED. FOR PIPE SIZES UP TO 2 INCHES, INSULATE WIT 1 INCH THICK (K =0.23 @ 7 °F) FIBERGLASS INSULATION WITH ALL SERVICE J CKET AND VAPOR BARRIER. FO' PIPE SIZES 2-1/2 INCHES AND LARGER, INSU ATE WITH 1 -1/2 INCH THICK (K =. 23 @ 75 °F) FIBERGLASS INSULATION WITH L SERVICE JACKET AND VAPOR BARRIER. b. INSULATION AT A L HANGERS FOR PIPING 2 1/2 INCHES AND LARGER SHALL BE HARD AND NO COMPRESSIBLE. c. ALL INSULATIO SHALL HAVE A FLAME SPREAD RATING 0 NOT MORE THAN 25 AND A SMOKE DEVELOPED RATING OF NO HIGHER THAN 51 TO CONFORM WITH THE REQUIRE ENTS OF THE NFPA. d. PROVIDE ZE TON OR EQUAL INSULATION FITTINGS FOR ALL T S, ELLS OR SPECIALTY ' ITTINGS. 6. GENERAL INS 'ALLATION a. INSTALL ATER MAINS WITHOUT PITCH. USE ECCENTRIC REDUCIN! COUPLINGS AT CHANGE IN SIZE WITH THE TOP OF PIPES AT SAME ELEVATION. b. BRANC ES TO UNITS BELOW MAINS TO BE TAKEN FROM BOTTOM 0 MAINS AT A 45 D REE ANGLE, PITCH DOWNWARD TOWARD UNITS. BRANCHES T• UNITS ABOVE MAIN TO BE TAKEN FROM TOP OF MAINS AT A 45 DEGREE ANGLE •ITCHED UP ARD TOWARDS UNITS. PITCH NOT LESS THAN 1" TO 10 FEET. c. SE r MECHANICAL DETAIL DRAWINGS FOR APPLICABLE DETAILS. N. REFRIG ''ANT PIPING: 1. THI. CONTRACTOR SHALL FURNISH AND INSTALL A COMPLETE REFRIGERANT SY TEM BETWEEN THE INDOOR FAN UNITS AND OUTDOOR CONDENSING UNITS. Tq PLANS TO DETERMINE IF A REFRIGERANT SYSTEM IS REQUIRED. 2. "IPIN G a. REFRIGERANT PIPING SHALL BE TYPE "L" HARD DRAWN COPPER TUBING (AST B88). TUBING SHALL BE CLEAN, CAPPED AND NITROGEN CHARGED. b. ALL FITTINGS AND JOINTS SHALL BE WROUGHT COPPER OR CAST BRONZE (ANSI B16.22). ALL COPPER TO COPPER JOINTS SHALL BE BRAZED WITH A COPPER - PHOSPHORUS ALLOY AND ALL OTHER JOINTS SHALL BE BRAZED WITH SILFOS -5 ALLOY. (PING REFER c. ALL ELBOWS ARE TO BE LONG RADIUS TYPE. REFRIGERANT PIPING (CONTINUED): INSTALLATION b. UCTION LINES SHALL HAVE ADEQUATE LIFT TRAPS AND /OR DOUBLE SUC R ,ERS TO MEET THE REQUIREMENTS OF FIELD CONDITIONS AND EQUIP MAN ACTURER'S RECOMMENDATIONS. BRAZE TOWARD T BROKEN LAS TIME THE SYST BEFORE LEAVING WITH AN INERT GAS SYSTEM IS TIGHT. EVAC CHARGE SYSTEM WITH 25 RETEST SYSTEM. ENERGIZE COMPRESSOR TO ENSURE THAT COMPRESSOR. JOINTS WITH SILFOS -5 STARTING AT THE INDOOR U OUTDOOR UNIT. THE SEALS ON THE OUTDOOR U A NITROGEN BLEED SHALL BE USED DURING IS OPEN. ALL OPEN LINES SHALL BE SITE DURING CONSTRUCTION. P TO 245 PSIG. REDO LEAKI TE ENTIRE SYSTEM TO I OF R -22 AND ANK CASE L REF c. UPON COMPLETION OF TESTING, B IS APPLIED, THE PIPING MUST INSPEC . D BY A REPRESENTATIVE OF THE LOCAL GOVERNING AUTHORIT AS NECESSA T AND WORKING T SHALL BE LL BRAZING AND ANY APPED AND SEALED SSURE TEST FOR LEAKS JOINTS AND RETEST UNTIL 00 MICRONS OF MERCURY. INERT GAS TO 245 PSI AND ATERS 24 HOURS PRIOR TO STARTING GERANT LIQUID IS OUT OF THE ORE THE REFRIGERANT PIPING INSULATION d. INSULATE THE REFRIGER RUBATEX OR ARMSTR RATING OF NOT MO THAN 50 IN ACC HOT GAS (LI0 D) 4. INSPECTION T SUCTION LINES A G 1 INCH THICK PIPE INSU THAN 25 AND A SMOKE DEVEL DANCE WITH INDUSTRY STANDARDS. LINES OR ANY HOT GAS BYPASS. NR CONDENSATE LINES WITH TION WITH FLAME SPREAD PED RATING OF NOT MORE 0 NOT INSULATE THE a. CONT' CTOR MUST PREPARE AND SUBMIT A COMPLETE PIPING SC ATIC TO THE LO IL MANUFACTURER REPRESENTATIVE FOR APPROVAL PRIOR TO B NNING STALLATION. UPON COMPLETION OF PIPING, THIS CONTRACTOR MUST C L THE LOCAL REFRESENTATIVE FOR FIELD INSPECTION OF WORK PERFORMED. ALL MS FOUND TO BE INADEQUATE FOR PROPER PERFORMANCE BY MANUFACTURER REPRESENTATIVE MUST BE CORRECTED. THIS INSPECTION IS PERFORMED AT JAM JUICE'S EXPENSE. 0. LABELS /PIPE MARKERS CONTINUED 1. FURNISH AND INSTALL PIPE IDENTIFICATION MARKERS ON ALL PIPES INSTALLED UNDER THIS CONTRACT. MARKERS SHALL BE A MINIMUM OF 1 -1/2" X 8" AND IDENTIFIED IN ACCORDANCE WITH THE BACKGROUND AND LETTER COLORS ISSUED BY THE AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI). 2. PIPING SHALL BE IDENTIFIED AS FOLLOWS: CHILLED WATER RETURN, CHILLED WATER SUPPLY, CONDENSATE, HOT WATER RETURN, HOT WATER SUPPLY, CONDENSER WATER RETURN, CONDENSER WATER SUPPLY, REFRIGERANT LIQUID, REFRIGERANT SUCTION, AND DIRECTIONAL ARROWS. ALL IDENTIFICATIONS MUST BE VISIBLE AT EQUIPMENT. CURBS FOR SUPPORT 1. THIS CONTRACTOR WILL FURNISH AND INSTALL ALL NECESSARY CURBS REQUIRED TO INSTALL ALL HVAC EQUIPMENT AS DESCRIBED ON THE DRAWINGS. CURBS SHALL BE A MINIMUM OF 14" (SHALL COMPLY WITH LOCAL AREA REQUIREMENTS) HIGH, OF THE SAME MANUFACTURER OF THE EQUIPMENT UNLESS NOTED OTHERWISE. ALL CURBS MUST BE INSTALLED SO THAT TOP OF CURBS ARE LEVEL. ALL PENETRATIONS OF EXISTING STRUCTURE SHALL BE DONE IN ACCORDANCE TO THE LANDLORD'S GUIDELINES AT THIS CONTRACTOR'S EXPENSE. THIS CONTRACTOR MUST RECEIVE JAMBA JUICE'S PROJECT MANAGER'S WRITTEN APPROVAL BEFORE ANY WORK TAKES PLACE. THIS CONTRACTOR IS ALSO RESPONSIBLE FOR ALL SEISMIC, HURRICANE OR OTHER SECURING DEVICES REQUIRED BY LOCAL OR OTHER CODES. Q. TESTING. ADJUSTING. AND BALANCING 1. TESTING, ADJUSTING AND BALANCING OF ALL WORK SHALL BE MADE BY AN INDEPENDENT CONTRACTOR WHO IS A CURRENTLY LICENSED ASSOCIATED AIR BALANCING COUNCIL (AABC) OR NATIONAL ENVIRONMENTAL BALANCING BUREAU (NEBB) BALANCING CONTRACTOR. NO OTHER BALANCE REPORTS WILL BE ACCEPTED. ALL BALANCING WORK MUST BE COMPLETE AND DONE IN ACCORDANCE WITH THE MOST RECENT STANDARDS OF THEIR SOCIETY. PAYMENT OF ALL COSTS FOR TESTING AND BALANCING SHALL BE INCLUDED IN THE BID. HOWEVER, IT WILL BE THE G.C. THAT WILL CONTRACT DIRECTLY WITH THE AIR BALANCING COMPANY. SCHEDULE BALANCING WITH OWNER'S FIELD REPRESENTATIVE. PROVIDE A COPY OF THE CERTIFIED AIR BALANCE REPORT AND CERTIFIED OUTSIDE AIR REPORT TO OWNER PRIOR TO OCCUPANCY. 2. FINAL TESTING, ADJUSTING AND BALANCING REPORT MUST BE COMPLETE AND SUBMITTED WITH FINAL CLOSE -OUT DOCUMENTS TO JAMBA JUICE 1 WEEK PRIOR TO MERCHANDISING DATE. 3. THE HVAC CONTRACTOR SHALL BE PRESENT FOR AIR BALANCE TO VERIFY ACCESSIBILITY TO ALL DEVICES, VERIFY ALL OPERATING SEQUENCES AND INSTALL NEW FILTERS IN ALL UNITS JUST PRIOR TO THE AIR BALANCE. THE COMPLETE AIR BALANCE SHALL TAKE PLACE WITH OUTSIDE AIR DAMPERS IN MINIMUM POSITION, EXCEPT AS NOTED OTHERWISE. HVAC CONTRACTOR SHALL ALSO INSTALL A NEW SET OF FILTERS ONE DAY PRIOR TO MERCHANDISING. 4. ALL CONTROL SEQUENCES SHALL BE TESTED (INTERLOCKED EQUIPMENT, SMOKE DETECTORS, SMOKE EVACUATION, ECONOMIZER, ETC.) AND OPERATING STATUS RECORDED IN THE BALANCE REPORT. 5. AIR BALANCING CONTRACTOR IS TO CONFIRM OVERRIDE OF MINIMUM OUTSIDE AIR INTAKE UPON CO2 MONITORING CONFIRMATION. FOR CO2 MONITORING CONTACT, SEE AIR BALANCE COVER SHEET. 6. THREE COPIES OF THE BALANCE REPORT SHALL BE SUBMITTED THROUGH THE GENERAL CONTRACTOR TO JAMBA JUICE FOR APPROVAL. THE GENERAL CONTRACTOR SHALL VERIFY THE COMPLETENESS OF THE REPORTS PRIOR TO SUBMITTING TO JAMBA JUICE. SUBMIT ONE COPY OF FINAL APPROVED AIR BALANCE REPORT TO MALL GENERAL MANAGER. 7. THE BALANCING CONTRACTOR SHALL PERFORM ALL APPLICABLE TESTING AND BALANCING FUNCTIONS REQUIRED FOR THE SYSTEM DESIGNED ON THESE DRAWINGS. ALL SYSTEMS UNABLE TO BE COMPLETELY BALANCED AT THE TIME OF ORIGINAL BALANCE MUST BE BALANCED IN FUTURE AT NO ADDITIONAL EXPENSE TO JAMBA JUICE. THE BALANCING CONTRACTOR SHALL RECHECK ANY ITEMS THAT JAMBA JUICE DEEMS NECESSARY AT NO ADDITIONAL COST TO JAMBA JUICE. P. END OF SECTION 15500 REFER TO OWNER'S SPECIFICATIONS FOR MORE INFORMATION AND COORDINATION WITH OTHER TRADES. 1. IT IS REQUIRED THAT THE MECHANICAL CONTRACTOR MUST VISIT THE JOBSITE TO FAMILIARIZE HIMSELF WITH MAJOR ITEMS SUCH AS STRUCTURAL ELEMENTS, PLUMBING LOCATIONS AND ELECTRICAL RUNS. ADDITIONALLY, MECHANICAL CONTRACTOR SHALL VERIFY EXACT LOCATIONS AND DIMENSIONS OF SUCH ITEMS AS H.V.A.C. UNITS, DUCTWORK, ETC., PRIOR TO SUBMITTING HIS BID. NO ADDITIONAL COMPENSATION WILL BE MADE FOR ANY EXTRAS DUE TO CONTRACTOR'S FAILURE TO VISIT THE JOBSITE AND /OR PRE - DETERMINE ALL EXISTING CONDITIONS BEFORE SUBMITTING HIS BID. ANY DISCREPANCIES SHALL BE IMMEDIATELY REPORTED TO THE OWNER'S FIELD REPRESENTATIVE FOR RESOLUTION. 2. ALL WORK SHALL BE DONE IN ACCORDANCE WITH ALL APPLICABLE GOVERNMENT AND LOCAL CODES AND LANDLORD'S REQUIREMENTS. 3. UNLESS OTHERWISE SPECIFIED, CONTRACTOR SHALL PROVIDE ALL EQUIPMENT, MATERIALS, LABOR AND SUPERVISION NECESSARY TO COMPLETE THE HEATING, VENTILATING AND AIR CONDITIONING WORK WHICH INCLUDES, BUT IS NOT LIMITED TO THE FOLLOWING: a. FURNISH AND INSTALL NEW AIR CONDITIONING UNIT AS SCHEDULED ON THE DRAWINGS. FURNISH AND INSTALL 4 "0, 24GA. GALVANIZED STEEL EXHAUST DUCT FROM DRYER (FIELD VERIFY EXACT SIZE AND LOCATION, MINIMUM OF 4 "). REMOVE ALL EXISTING DUCTWORK AND EQUIPMENT NOT TO BE RE -USED AND DISPOSE OF SAME OFF LANDLORD'S PREMISES. FURNISH AND INSTALL ALL NEW DUCTWORK INCLUDING GRILLES, DIFFUSERS AND DAMPERS IN ACCORDANCE WITH S.M.A.C.N.A. CURRENT STANDARDS AND THE LANDLORD'S REQUIREMENTS - (SHOWN ON PLANS AS SOLID LINES). 1. ALL MATERIAL SHALL BE NEW AND OF COMMERCIAL GRADE, AND BEAR UNDERWRITER'S AND UNION LABELS WHERE SUCH LABELING APPLIES. 2. ALL DUCTWORK SHALL BE FABRICATED FROM GALVANIZED SHEET METAL IN ACCORDANCE WITH THE STANDARD OF AMERICAN SOCIETY, REFRIGERATION AND AIR CONDITIONING ENGINEERS NATIONAL ASSOCIATION, FOR LOW PRESSURE, LOW VELOCITY DUCTWORK OR AS PER LOCAL CODE. b. c. d. 3. BRANCHES FROM MAIN LOW VELOCITY TRUNK DUCTWORK SHALL BE FURNISHED WITH SPLITTERS, DAMPERS OR SIMILAR BALANCING DEVICES IN ACCORDANCE WITH THE STANDARDS OF THE ASSOCIATED AIR BALANCING COUNCIL. (FIRE DAMPERS SHOULD BE PROVIDED AS REQUIRED BY ANY APPLICABLE CODES AND /OR JURISDICTIONAL AUTHORITIES). 4. ALL DUCTS FOR FINAL CONNECTION TO DIFFUSER SHALL BE CLASS 1 U.L. LISTED (SL 181) FLEXIBLE AIR DUCT NOT TO EXCEED 5' -0" IN LENGTH (THERMAFLEX, GLASSFLEX OR APPROVED EQUAL). 5. SUPPLY DUCTWORK SHALL BE INSULATED WITH ONE (1) INCH THICK MINIMUM BLANKET INSULATION WITH VAPOR BARRIER. ACOUSTICAL LINER MAY BE PROVIDED AS REQUIRED PER NFPA STANDARDS, I.R.I. REQUIREMENT AND UL RATED. (EQUAL TO MANVILLE FIBERGLASS INSULATION) 4. ALL COMPONENTS AND EQUIPMENT SHALL BE PROVIDED WITH AN EASE OF SERVICE AND MAINTENANCE AS REQUIRED BY CODE AND THE LANDLORD. 5. FURNISH AND INSTALL THERMOSTAT AS SHOWN ON THE PLAN AT A MIN. OF 3FT - MAX. OF 4FT A.F.F. (VERIFY LOCAL CODES). COORDINATE EXACT LOCATION WITH OWNER'S REPRESENTATIVE. PROVIDE CONTROL WIRING AND CONTROLS AS REQUIRED. 6. CONTRACTOR SHALL PROVIDE PRODUCT DATA SUBMITTALS FOR ALL EQUIPMENT AND DEVICES TO THE OWNER FOR HIS REVIEW AND /OR APPROVAL PRIOR TO THE PURCHASE OF ANY SUCH EQUIPMENT OR DEVICES. 7. CONTRACTOR SHALL PROVIDE A/C UNIT FILTER REPLACEMENT AFTER CONSTRUCTION IS COMPLETE. 8. INSTALLATION ACCEPTANCE MAY BE SUBJECT TO CONSTRUCTION REVIEW BY AN INDEPENDENT AIR CONDITIONING FIRM. 9. UPON COMPLETION OF THE WORK, THE CONTRACTOR SHALL TEST, START -UP AND BALANCE THE SYSTEM(S) AND MAKE ANY ADJUSTMENTS AS REQUIRED TO INSURE PROPER WORKING ORDER. ADJUST AIR QUANTITIES TO WITHIN 10% OF DESIGN VALUES. SUBMIT A COPY OF AIR BALANCE REPORT BY AN OUTSIDE CERTIFIED AIR BALANCE TECHNICIAN, CERTIFIED BY THE AABC (ASSOCIATED AIR BALANCE COUNCIL) OR NEBB (NATIONAL ENVIRONMENTAL BALANCING BUREAU), AND A COPY OF REPRODUCIBLE SET OF THE "AS- BUILT" DRAWINGS TO THE OWNER AND TO THE LANDLORD FOR THE RECORDS AND TO THE DESIGN ENGINEER'S OFFICE PRECEDENT TO FINAL PAYMENT. NOTE: SMOKE DETECTORS INSTALLED WITHIN AIR MOVING SYSTEMS SHALL BE FULLY TESTED TO THE SATISFACTION OF THE LOCAL FIRE DEPARTMENT. TESTING SHALL CONFORM TO THE REQUIREMENTS OF THE LOCAL FIRE DEPARTMENT. HVAC SY V BOLS SYMBOL DESCRIPTION THERMOSTAT REMOTE SENSOR x SUPPLY DIFFUSER RETURN GRILLE EXHAUST GRILLE RECTANGULAR DUCT (FIRST FIGURE IS SIDE SHOWN) OUTSIDE AIR CALCULATION ROUND DUCT SMOKE DETECTOR ROOM NAME AREA (SQ.FT.) 0/A PER 2009 SEATTLE MECHANICAL CODE CFM /SQ.FT. SQ.FT. /PERSON MAX. OCC. CFM REQ. AUTOMATIC BACKDRAFT DAMPER CUSTOMER 0.30 UNDERCUT DOOR 1" SERVICE 268 100 3 75 STORAGE 160 0.15 24 J FLEXIBLE DUCTWORK. 5' -0" MAX. TOILET 75 CFM EXHAUST PER WATER CLOSET MANUAL BALANCING DAMPER UNCONDITIONED 188 TOTAL REQUIRED 99 TOTAL 616 TOTAL PROVIDED 160 DIRECTION OF AIR FLOW NEW TO EXISTING CONNECTION 1 THESE PLANS MAY BE USED FOR CONSTRUCTION ONLY AFTER APPROVAL IS OBTAINED FROM THE BUILDING DEPARTMENT MECHANICAL PLAN CHECK DIVISION AND THAT DIVISION'S STAMP APPROVAL AND AUTHORIZED SIGNATURE APPEAR ON THE PLANS. 2. COORDINATE ALL WORK WITH ARCHITECTURAL, ELECTRICAL, PLUMBING, FIRE SPRINKLER AND STRUCTURAL CONTRACTORS. INSTALL ALL WORK TO CLEAR NEW AND EXISTING ARCHITECTURAL AND STRUCTURAL MEMBERS. NO ITEM SUCH AS PIPE, DUCT, ETC. IS TO BE IN CONTACT WITH ANY EQUIPMENT. 3. REFER TO ARCHITECTURAL DRAWINGS FOR DEMOLITION WORK. 4. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT FIXTURE LOCATION. 5. REFER TO THE MECHANICAL SHEETS FOR DETAILS, SCHEDULES AND SPECIFICATIONS. 6. CONTRACTOR SHALL PROVIDE CUT SHEETS TO JAMBA JUICE FOR ALL EQUIPMENT AND DEVICES FURNISHED BY THE CONTRACTOR THAT DEVIATE FROM SPECIFIED ITEM FOR REVIEW AND APPROVAL PRIOR TO THE PURCHASE OF ANY SUCH EQUIPMENT OR DEVICES. 7. HVAC CONTRACTOR IS RESPONSIBLE TO INQUIRE WITH THE LANDLORD'S REPRESENTATIVE ON ANY SMOKE EVACUATION SYSTEM IN USE AT THE MALL AT THE TIME OF THE BID. IF THE SAID SYSTEM IS NOT ADEQUATELY DESCRIBED ON THE DRAWINGS, THE MECHANICAL CONTRACTOR IS RESPONSIBLE TO INFORM THE GENERAL CONTRACTOR AND INCLUDE THE COST AS A SEPARATE LINE ITEM IN THE BID. NO ADDITIONAL MONIES SHALL BE AWARDED FOR TIE -IN REQUIREMENTS TO A LANDLORD'S SMOKE EVACUATION SYSTEM THAT IS IN EXISTENCE AT THE TIME OF THE BID, WITHOUT A SEPARATE LINE ITEM FOR THE SMOKE EVACUATION SYSTEM AT THE TIME OF THE BID. 8. ACCESS TO ALL COMPONENTS AND EQUIPMENT MUST BE PROVIDED TO MEET CODE AND SERVICE /MAINTENANCE EASE. 9. PRIOR TO STARTUP OF HVAC EQUIPMENT, MECHANICAL CONTRACTOR WILL CONFIRM WITH HVAC MANUFACTURER THAT CORRECT POWER IS PROVIDED TO HVAC UNITS AND HAS BEEN TURNED ON A MINIMUM OF 24 HOURS. JAMBA JUICE RESERVES THE RIGHT TO CHECK CONSTRUCTION COMPLIANCE WITH PLANS AND SPECIFICATIONS. SHOULD JAMBA JUICE FIND CORRECTIVE WORK TO BE NECESSARY, THEY WILL NOTIFY CONTRACTOR OF SUCH WORK IN WRITING AND EXPECT COMPLIANCE PERFORMED WITH DUE DILIGENCE. IF ANY CORRECTIVE WORK IS DEEMED TO BE NECESSARY, THE COST OF REINSPECTIONS WILL BE BORNE BY THE CONTRACTOR. 10. IF WORK IS REQUIRED BY JAMBA JUICE IN ORDER TO IMPROVE, CHANGE OR CORRECT AIR CONDITIONING OPERATIONAL CONDITIONS DUE TO: PART MALFUNCTION, WARRANTY OR OTHER INABILITY TO PROVIDE THE COMFORT CONDITIONS REQUIRED BY THE STORE, CONTRACTOR SHALL BE DIRECTED BY JAMBA JUICE TO ADDRESS THIS WORK IN A TIMELY MANNER. IF IT BECOMES EVIDENT THAT THE CONTRACTOR CANNOT ACCOMPLISH THE TASK, THEN AFTER 72 HOURS OF WRITTEN NOTICE THE OWNER MAY, AT HIS DISCRETION TAKE OVER SUCH WORK AND BACKCHARGE THE CONTRACTOR FOR ANY CORRECTIVE WORK THAT WAS REQUIRED DUE TO LACK OF PERFORMANCE, WORKMANSHIP AND /OR ADHERENCE TO PLANS AND SPECIFICATIONS. 11. UPON COMPLETION OF THE WORK, CONTRACTOR SHALL ENSURE THE PROPER WORKING ORDER OF THE SYSTEM(S) AND MAKE ANY ADJUSTMENTS AS REQUIRED. REVIEWED FOR CODE COMPLIANCE APPROVED AUG 19 2011 City of Tukwila BUILDING DIVISION HVAC LOAD CALCULATION DESIGN CONDITIONS OUTDOOR INDOOR SUMMER DRY BULB 85 75 SUMMER WET BULB 65 62.5 HUMIDITY RATIO 61 65 WINTER DRY BULB 28 70 SUMMER DESIGN MONTH' JULY DAILY SWING DIFFERENCE 10 3 0 42 18 DATE 7/18/2011 CLIENT ADDRESS CITY & STATE ASHRAE CITY ALTITUDE 47.45 LEASE AREA 616 JOB # 110179 Jambs Juice # 561 566 Southcenter Mall Seattle, WA 98188 Seattle, WA LATITUDE 449 SQ. FT. C 0 N D U C T ITEM ROOF WALL WALL WALL WALL GLASS DIR. CLTD LAT CORR K IAT ODA AVG CORR U CORR TEMP CORR CLTD VAL 1 3 0.00 81.00 0. 10 1 3 0.00 22.00 0.10 1 3 0,00 38,00 0.10 1 3 0.00 40.00 0.10 1 3 0.00 31. 00 0, 10 1 3 0.00 17.00 0. 90 CREDIT TO SENSIBLE FOR L.L. RETURN SYSTEM FLAT 78 1 NORTH 19 1 SOUTH 35 1 EAST 37 1 WEST 28 1 ALL 14. 1 ITEM DIR. SC S 0 GLASS NORTH 0.88 L GLASS SOUTH 0.88 A GLASS EAST 0.88 R GLASS WEST G. 88 L TYPE WATTS I SHGF 40 72 215 47 CLF AREA 0.76 0 0.53 0 0.29 0 0.40 0 X BTH /WATT SUBTOTALS NOTES X FACTOR X % TO SPACE G FLUORESCENTS 412 3.41 1.10 H FLUORESCENTS 0 3.41 1.10 T INCANDESCENTS 528 3.41 1.00 S INCANDESCENTS 0 3.41 1.00 E ITEM Q U EQUIP, 2 . 5W /SF 0 0.5 3.410 0 I OTHER 0.5 3.41 0 P EQUIPMENT 25000 0.25 3.41 21313 0.75 1.00 1.00 0.75 VALUE X MULTIP = BTU /H OR ASHRAE BTUH AREA 616 0 0 0 0 0 RECESS SURF SURF RECESS PEOPLE 100 SQ,FT. /PERSON 315 BTUH /PERSON LANDLORD AIR SUPPLY' TEMPERATURE' 57 HUMIDITY RATIO' (ASSUMED ( ROOM W) HEATING LOAD AT MIN. CFM SETPOINT COMBINED DUCT LOSS, INFILTRATION, WARM -UP AND SAFETY MARGIN a 10% BTUH BTUH COOLING HEATING 4990 2587 0 0 0 0 0 0 0 0 0 0 -1996 2994 2587 0 0 0 0 1159 0 1800 0 0 0 21313 1940 2921 1321 ROOM SENSIBLE HEAT GAIN (LOSS) = 32127 3909 L A T E N T O T H E R PEOPLE EQUIPMENT 100 SQ. FT. /PERSON (LISTED AS ATTACHED) 325 BTUH /PERSON ROOM LATENT HEAT GAIN = ITEM QTY FACTOR FACTOR LIGHTS IN PLENUM 453 3. 41 0.25 ROOF LOAD TO L. L. SYSTEM 2002 0 2002 386 1996 T O T A L S SENSIBLE LOAD LATENT LOAD SENSIBLE HEAT RATIO MINIMUM CFM MAXIMUM CFM 34509 2002 0. 95 92 1623 TOTAL COOLING LOAD (BTUH) NOMINAL TONS REQUIRED HEATING (BTUH) ELECTRIC HEATING (KW) r1-11%-- fa, 36511 a04 3909 0.88 P1? DANIEL A. REEVES, P.E. 3100 E. Rondo! Mill Rd Arlington, TX 76011 (817)633 -4200 FAX (817)633 -4153 Washington License #44016 EXPIRES 1 woru6lsapswpd 3100 East Randol Mill Road Arlington, Texas 76011 817.633.4200 p • 817.633.4153 f W J I` J ZQ W2 W = w 011_ Z Ow CO = 0 F- CC W:3 0 LL I" (1) O W LO O w U 00 00 co Cn w J w ca 0 ti 0 w m Z i- w tY 0 Issue Date 7/28/11 Drawn By Appv'd By AQ DAR Revisions Date A Description By A A A c r ro�u A A P KMIT CENTS J6.0 VERSION 4 -31 -08 6.0.0 Mechanical Specs. M -002 1 2 3 4 5 6 7 8 9 10 THERMOSTAT AND SENSORS MARK LOCATION MANUFACTURER MODEL NUMBER REMARKS V05 BACK AREA TITUS TA1 F &I BY G.C. DIFFUSERS, GRILLES AND REGISTERS MARK SERVICE LOCATION CLG. TYPE MANUFAC. CATALOG NUMBER REMARKS D -1 SUPPLY CEILING AC. TILE TITUS PAS XX 24x24 3 26 SEE PLAN FOR NECK SIZE D -2 SUPPLY CEILING GYP TITUS PAS XX 24x24 1 26 SEE PLAN FOR NECK SIZE 8.0 1 480V/3 TAT TBDI 30 SL TS, L NC) PR VIDE TRIM AS REQUIRE 3 SUPPLY CEILING GYP (4x1" ,41' G -1 RETURN CEILING AC. TILE TITUS PAR 22x22 24x24 3 26 VARIABLE AIR VOLUME BOX (BY TENANT GENERAL CONTRACTOR) MARK MANUFACTURE MODEL NUMBER MAXIMUM CFM MINIMUM CFM SIZE CONTROL ELECTRIC HEAT COIL VOLTS /0 UNIT OUTLET CFM KW STEPS vol TITUS # ATQP 1600 0 12 16.5x14 ANALOG 1,600 8.0 1 480V/3 EXISTING 14"0 SUPPLY DUCT TO REMAIN. VERIFY EXACT LOCATION IN FIELD. EXISTING 8 "0 EXHAUST DUCT TO REMAIN. VERIFY EXACT LOCATION IN FIELD 350 CFM 10"0 D-1 i 1 . 1 1 12 "fib -Co 0 1 2.4- 16/16 S s (IV1> — 10 "0 1/-1 A G -1 s. o R A I I G -1 +48" z S A Q 4 V05 121'0 ` 350 CFM 10 "0 D -1 I I I I � I 1 i 0 MECHANICAL PLAN 450 CFM 12"0 I D -2 2 -WAY 450 CFM 12"0 I D -2 2 -WAY SCALE: 1 /4" = 1' -0" NECK AND RUNOUT SIZE. (SUPPLY TRANSITION AS REQUIRED TO CONNECT BRANCH DUCT AS SHOWN) r CUBIC FEET PER MINUTE 300 CFM 12 "0I D -1 DIFFUSER /GRILLE TYPE (REFER TO SCHEDULE) DIFFUSER /GRILLE TAG NORTH 6))))07:ge, DR DANIEL A. REEVES, P.E. 3100 E. Randal Mill Rd Arltngton, TX 76011 (817)633 -4200 FAX (817)633 -4153 Washington License #44016 woY U6lsapswpd 3100 East Rondo! Mill Road w M '0 N. o O 0_ X o F • o ry c � O M • M m .0 C • ▪ N 00 MECHANICAL GENERAL NOTES VECHANICAL KEYED NOTES A "VERIFY IN FIELD" OR "EXISTING" MEANS THE CONTRACTOR IS TO CONFIRM THE ITEM SHOWN ON THE DRAWING (I.E. EQUIPMENT, DUCT, WIRE, ETC.) EXISTS AT THE SITE AND IS IN GOOD WORKING CONDITION. SHOULD THE CONTRACTOR FIND THAT THE EQUIPMENT, DUCT, WIRE, ETC. IS NOT THE EQUAL TO THAT SHOWN ON THE DRAWING, IT IS TO BE REPLACED, IF THE CONTRACTOR HAS ANY QUESTION ABOUT WHETHER IT IS EQUAL TO WHAT IS SHOWN ON THE DRAWING, THE CONTRACTOR IS TO CONTACT THE DESIGN ENGINEER AND JAMBA JUICE'S PROJECT MANAGER FOR APPROVAL. CONTRACTOR IS TO NOTIFY JAMBA JUICE'S PROJECT MANAGER AND DESIGN ENGINEER IN WRITING OF ALL REPLACEMENT ITEMS PRIOR TO CONSTRUCTION. B WHERE EXISTING EQUIPMENT (LIGHTS, DIFFUSERS, TOILETS, ETC.) ARE TO BE REUSED, WHETHER IT IS RELOCATED OR REUSED IN THE EXISTING LOCATION, EXTREME CARE SHALL BE TAKEN TO PREVENT DAMAGE DURING THE RENOVATION OF THE STORE. WHERE DAMAGE OCCURS, THE EQUIPMENT SHALL BE REPLACED TO THE SATISFACTION OF THE ARCHITECT, AT NO ADDITIONAL COST TO THE OWNER. ALL ITEMS TO BE THOROUGHLY CLEANED, IF REQUIRED, PAINTED, AND ANY OTHER MAINTENANCE NEEDED TO BRING EQUIPMENT UP TO LIKE NEW CONDITION. THIS INCLUDED RELAMPING ALL LIGHTS REUSED. C EXISTING CONDITIONS ARE BASED ON "AS- BUILT" DRAWINGS PROVIDED BY THE OWNER. CONTRACTOR SHALL ADJUST TO ACTUAL FIELD CONDITIONS AT NO ADDITIONAL EXPENSE TO THE OWNER. D CONTRACTOR SHALL FAMILIARIZE HIMSELF WITH DEMOLITION WORK PRIOR TO BIDDING AND START OF WORK. CONTRACTOR IS RESPONSIBLE TO DEMOLISH ALL EXISTING AS REQUIRED FOR INSTALLATION /CONSTRUCTION OF NEW WORK. E GENERAL CONTRACTOR SHALL COORDINATE RESPONSIBILITY BETWEEN MECHANICAL AND ELECTRICAL CONTRACTOR, ALL LINE VOLTAGE AND LOW VOLTAGE REQUIREMENTS FOR A COMPLETE PROJECT F COORDINATE DUCT ROUTING AND HEIGHTS WITH GENERAL CONTRACTOR. VERIFY ALL CLEARANCES BEFORE STARTING WORK. G THE CONTRACTOR SHALL OBTAIN A COPY OF THE LANDLORD'S TENANT CRITERIA MANUAL. TENANT CRITERIA MANUAL REQUIREMENTS SHALL BE INCLUDED IN THIS CONTRACT. CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLYING WITH LANDLORD REQUIREMENTS AT NO EXTRA COST TO THE TENANT. H NO EQUIPMENT OR COMPONENTS MAY BE ABANDONED WITHOUT WRITTEN PERMISSION OF THE LANDLORD. ALL ROOFING WORK SHALL BE DONE BY THE LANDLORD'S ROOFING CONTRACTOR AT T.G.0 EXPENSE. J CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFICATION OF ALL EXISTING CONDITIONS PRIOR TO SUBMITTING HIS BID. NO ADDITIONAL COMPENSATION WILL BE MADE FOR ANY EXTRAS DUE TO CONTRACTOR'S FAILURE TO VISIT THE JOBSITE AND /OR PREDETERMINE ALL EXISTING CONDITIONS BEFORE SUBMITTING HIS BID. ANY DISCREPANCIES SHALL BE IMMEDIATELY REPORTED TO THE ENGINEER FOR RESOLUTION. K ALL WORK SHALL BE COMPLETED IN ACCORDANCE WITH ALL APPLICABLE GOVERNMENT AND LOCAL CODES. L A FREE AREA FOR MAINTENANCE ACCESS AROUND THE HVAC EQUIPMENT SHALL BE PROVIDE. VERIFY CLEARANCE WITH LOCAL CODE AND MANUFACTURERS REQUIRED SERVICE ACCESS. M THE MECHANICAL CONTRACTOR SHALL INSPECT AND RUN TEST ALL EXISTING UNITS AT THE START OF CONSTRUCTION AND INFORM THE OWNER'S REPRESENTATIVE OF ANY NECESSARY REPAIRS FOR APPROVAL IN A TIMELY MANNER TO NOT DELAY THE STORE OPENING DATE. N FILTER MEDIA SHALL BE UTILIZED TO PROTECT ALL RETURN OPENINGS DURING CONSTRUCTION. O FLEX DUCTS SHALL BE LIMITED TO A MAX. LENGTH OF 5' -0" PER BRANCH RUNOUT. P THE GENERAL CONTRACTOR AND MECHANICAL SUB - CONTRACTOR SHALL VERIFY AND INCLUDE IN THEIR FINAL BID ALL LIFE SAFETY, SMOKE /FIRE ALARM SYSTEMS NEEDED TO BRING TENANTS SPACE COMPATIBLE WITH THE LANDLORD'S SYSTEM, AND CURRENT WITH LOCAL AND STATE CODES. FAILURE TO DO SO SHALL RESULT IN NO EXPENSE TO THE TENANT. O T.G.0 SHALL INSTALL A NEW VAV BOX WITH INDIVIDUAL CONTROL BY TENANT. COORDINATE MOUNTING LOCATION WITH LANDLORD. PROVIDE LOW PRESSURE DUCTWORK AND BALANCE AIRFLOW TO QUANTITIES SHOWN. ® PROVIDE 12 "0 CONNECTION TO LANDLORDS MEDIUM PRESSURE SUPPLY DUCT. VERIFY EXACT LOCATION IN FIELD AND MODIFY LAYOUT AS REQUIRED TO MATCH. UMW- REVIEWED FOR CODE COMPLIANCE APPROVED AUG 19 2011 City of Tukwila BUILDING DIVISION JAMBA JUICE W J I— J ZQ W 2 • w I- 1_ • Z O w u)0 W .O 16 CO ■ (0 W Lo O w U SEATLLE, rn 0 PROJECT NUMBER: Issue Date 7/28/11 Drawn By AQ Appv'd By DAR Revisions Date Description By A A A RECEIV CITY OF TU LA A A PERMIT CENTER J6.0 VERSION 4 -31 -08 6.0.0 Mechanical Plan M -101 AIR FOL W 4 5 6 7 8 9 10 ROUND DUCT DAMPER HANDLE TO BE INSTALLED MAXIMUM OF 3' -0" ABOVE CEILING. l 18 " LONG ORANGE MARKER =1 TAPE ATTACHED TO DAMPER TO IDENTIFY LOCATION INSULATED FLEXIBLE CONNECTION (MAX. 5' -0 ") FIRE DAMPER WHERE INDICATED ON PLANS. SUPPLY AIR DIFFUSER (LAY —IN FRAME) CEILING DIFFUSER MOUNTING DETAIL WHERE REQUIRED, PROVIDE VOLUME DAMPER WITH LOCKING QUADRANT. PROVIDE WITH 3" EXTENDED SHAFT AND HANDLE SHT. MTL. ELBOW REQUIRED SECURELY TAPE VINYL FLEX DUCT TO SHT. MTL. W/ MIN. OF (2) CONTINUOUS WRAPS OF DUCT TAPE. STRAP CLAMP OVER FLEX DUCT INSULATION & VINYL TO SHT. MTL. TAPE INSULATION TO DUCT TO FORM A GOOD SEAL 8" LONG SHT. MTL. SECTION SECURED TO DIFFUSER COLLAR W/ MIN. (3) SHT. MTL. SCREWS, DUCT TAPE AND MASTIC. TRANSITION FROM DUCT SIZE TO DIFFUSER NECK SIZE AS NECESSARY THERMAL INSULATING BLANKET REQUIRED FOR FIRE RATED CEILINGS ONLY. CEILING MOUNTING LAY IN APPLICATION (BORDER TYPE 3). FOR GYP. CEILING APPLICATION USE SURFACE MOUNTED DIFFUSER (BORDER TYPE 1). SCALE: N.T.S. STRAP OR ANGLE TRAPEZE HANGERS ROD �► SIZE BOLT(S) FOR LOAD STRAP HANGERS HANGER STRAPS Iiiiiiiiiiii". . SCREWS UNLESS FOOT OF STRAP IS PLACED UNDER A BOTTOM REINFORCEMENT SCREWS MAY BE OMITTED IF HANGER LOOPS MIN. NOTE: FOR ADDITIONAL INFORMATION REFER TO THE LATEST EDITION OF SMACNA 0 TABLE 4 -1 — RECTANGULAR DUCT HANGERS — MINIMUM SIZE MAX. HALF OF DUCT PERIMETER PAIR AT 10' SPACING PAIR AT 8' SPACING PAIR AT 5' SPACING PAIR AT 4' SPACING STRAP WIRE /ROD STRAP WIRE /ROD STRAP WIRE /ROD STRAP WIRE/ROD P 30° 1" x 22 ga. 10 ga. 1" x 22 ga. 10 ga. 1 "x22 12 ga. 1 "x22 12 ga. = 2 (.135) (.135) ga. (.106") ga. (.106") P 72" 1" x 18 ga. 3/8° 1" x 20 ga. 1/4" 1" x 22 ga. 1/4" 1" x 22 ga. 1/4" = 2 P 96" 1" x 16 ga. 3/8" 1" x 18 ga. 3/8" 1" x 20 ga. 3/8" 1" x 22 ga. 1/4" = 2 P 120" 2 = 1 1/2" x 16 ga. 1/2" 1" x 16 ga. 3/8" 1" x 18 ga. 3/8" 1" x 20 ga. 1/4" P 168" 1 1/2" x 16 ga. 1/2" 1 1/2" x 16 ga. 1/2" 1" x 16 ga. 3/8" 1" x 18 ga. 3/8" = 2 P 192" — 1/2" 1 1/2" x 16 ga. 1/2" 1" x 16 ga. 3/8" 1" x 18 ga. 3/8" = 2 P 193 "up SPECIAL ANALYSIS REQUIRED = 2 RECTANGULAR DUCT HANGER ATTACHMENT DETAIL SCALE: N.T.S. D • HANGER STRAP SHEET MTL. DUCT HANGER INSULATION SPIRAL DUCT SPIRAL DUCT HANGER DETAIL SCALE: N.T.S. t" 617 ••-) DR DANIEL A. REEVES, P.E. 3100 E. Randal Mill Rd Arlington, TX 76011 (817)633 -4200 FAX (817)633 -4153 Washington License #44016 A B x TURNING VANES 15° OR LESS A AIR FLOb TRANSFORMATION 90° ELBOW X 15' OR LESS EXPANSION THREE TURNING VANES 45° ELBOW SIMILAR NO THROAT RADIUS 1 SUPPLY OR RETURN WYE (RECTANGULAR DUCT) 1 D 3/4 D RETURN AIR BRANCH FITTING DUCTWORK DETAILS TURNING VANES TURNING VANE 2/3D SHORT RADIUS 90° ELBOW TAKE —OFF USE ONLY IN AREAS WHERE SPACE IS LIMITED AIR LOS CONTRACTION FULL RADIUS FULL RADIUS ELBOW TAKE —OFF SCALE: N.T.S. ALTERNATE TAP LOCATION. MAX FLEX DUCT LENGTH = 5' -0 ". NO TURNS GREATER THAN (1) 90 ° TURN PERMITTED. SUPPLY DUCT END OF DUCT -Th CEILING DIFFUSER FLEX DUCT (5' MAX LENGTH) DIFFUSER & RECTANGULAR DUCT CONNECTION SCALE: N.T.S. NOTES: 1. COORDIN '' BURGLAR BARS 2. INSTALL BUR, AR BARS AT AND /OR ROOF 0 INGS. 3. #6 BARS TO HAVE MOUTH 4. AFTER BARS ARE INS LED WITH MECHANICAL EQUIPMENT. OPENINGS WHICH EXCEED 9" SQUARE AT SURFACE (NOT RIBBED OR DEFORME WELD OR PEEN NUT TO BOLT. REBAR). VENT TO PLAS CEMENT ST' M COLLAR OF FLASHING ROOF AND INSULATION DECK INSULATE VENT PIPE #6 CROSS BARS ® 6" ON CENTER #6 BARS 0 6" ON CENTER PATC AS (E 4" X 2-1/2" F.B. ME — ATTACH TO TURAL FRAMING 2" DIAMETER 8" ON CENTER 2 M.B. EACH F- STR► WITH M.B. A — MINIMU SIDE OF BA DUCT LINING ND REPAIR ROOF CESSARY TO MATCH COORDINATE WITH NDLORD'S ROOFING ONTRACTOR, TYP. TO MAINTAIN ROOF WARANTY. BURGLAR BARS DETAIL GAS APPLIANCE VENT SCALE: N. SCALE: N. . SEISMIC BRACING AND SIZING BRACE SIZING BRACING SPACING BRACE SIZE 2 "x2 "x3/16" ANGLE 2- 1/8 "x2 -1/8 "x3/16" ANGLE 3 "x3 "x3/16" ANGLE 3- 1/2 "x3 -1/2 "x1/4" ANGLE 4 "x4 "x1/4" ANGLE 3" DIAM. PIPE MAXIMUM LENGTH 6' -0" 8' -0" 10' -0" 11' -6" 13' -0" 13' -0" TO 18' -0" PIPE SIZE UP TO 1 -1/2" 2" 2 -1/2" TO 3" 4" AND UP MAXIMUM HANGER SPACING 7' -0" 10' -0" 10' -0" 10' -0" MAXIMUM BRACE SPACING* (SEE NOTE 2) NOT REQUIRED NOT REQUIRED 7-0" 10' -0" NOTES: 1. DUCTS WHICH ARE LARGER THAN 6 SQUARE FEET IN CROSS SECTION AREA SHALL BE BRACED LATERALLY 7-0" ON CENTERS WITH 2" x 2" x 3/16° ANGLE. * 2. BRACING CAN BE OMITTED ON ALL PIPING SUSPENDED BY INDIVIDUAL HANGERS 12" OR LESS IN LENGTH FROM THE TOP OF PIPE TO THE BOTTOM OF NE SUPPORT FOR THE HANGER. 3. MECHANICAL SERVICES CEILING MOUNTED AIR TERMINALS OR SERVICES WEIGHING LESS THAN 20 POUNDS SHALL BE POSITIVELY ATTACHED TO THE MAIN RUNNER. TERMINALS OR SERVICES WEIGHING BETWEEN 20 POUNDS AND 56 POUNDS SHALL ALSO HAVE TWO NO. 12 GAUGE HANGER WIRES CONNECTED FORM THE TERMINAL TO THE STRUCTURE ABOVE. THESE WIRES MAY BE SLACK. SEISMIC BRACE SCHEDULE SCALE: N.T.S. PIPE OR CONDUIT REDWOOD BLOCKING AT ON CENTER MAXIMUM GALV. METAL FAS SECURED WITH ER SCREWS • r• REVIEWED FOR CODE COMPLIANCE APPROVED AUG 19 2011 City of Tukwila BUILDING DIVISION NOTE: PATCH AND REP •' ROOF AS NECESSARY TO MATCH (E) COORDINA 11-1 LANDLORD'S ROOFING CONTRACTOR, . ROOFING CONTRACTOR, TO MAINTAIN R• •F WARANTY. /J r . f PIPE SUPPORT BLOCKING INVERTED MODIFIED ITUMEN CAP SHEET SET MASTIC CEMENT (E) B — VERI IN FIELD T —UP ROOFING SCALE: N. EXPIRES pa31,.....1 woyalsapswpd 3100 East Randol Mill Road 0 N. 0 X a 9— M .D N. 5 0 o. 0 0 V M M JAMBA JUICE W I— ZQ W 2 V = w • Z O w U) U WD I-. co U W Lo 00 00 00 V, >'Q SEATLLE, PROJECT NUMBER: Issue Date 7/28/11 Drawn By Appv'd By AQ DAR Revisions Date A Description By A\ A A cnvFRuNvnLA AUG 01 2011 A P ERMIT CENTE R J6.0 VERSION 4 -31 -08 6.0.0 Mechanical Details M -501 1 2 3 4 5 6 7 8 10 3M.E.P. ROOF PLAN SCALE: 1/4" = 1' -0" NORTH REVIEWED FOR CODE COMPLIANCE 41 APPROVED AUG 19 2011 City of Tukwila BUILDING DIVISION Sh,:in r 141 DR DANIEL A. REEVES, P.E. 3100 E. Randol Mill Rd Arlington, TX 76011 (817)633 -4200 FAX (817)633 -4153 Washington License #44016 EXPIRES 0,7 woru6lsepswpd 3100 East Rondo! Mill Road Lrf M o • C° N e o Q) • o o O • m 011 m C • Q 07) KEYED NOTES 0 WALK -IN COOLER CONDENSING UNITS MOUNTED ON ROOF. VERIFY REQUIREMENTS WITH MANUFACTURER PRIOR TO INSTALLATION. ML(1O � GENERAL NOTES cc W 1� J Z Q W2 W V I w z Ow ca mom= a W - �0 ILL CO H cfl V) co W O CLw U CO CO T"" CO 0, —J (1) w J H w PROJECT NUMBER: A "VERIFY IN FIELD" OR "EXISTING" MEANS THE CONTRACTOR IS TO CONFIRM THE ITEM SHOWN ON THE DRAWING (I.E. EQUIPMENT, DUCT, WIRE, ETC.) EXISTS AT THE SITE AND IS IN GOOD WORKING CONDITION. SHOULD THE CONTRACTOR FIND THAT THE EQUIPMENT, DUCT, WIRE, ETC. IS NOT THE EQUAL TO THAT SHOWN ON THE DRAWING, IT IS TO BE REPLACED, IF THE CONTRACTOR HAS ANY QUESTION ABOUT WHETHER IT IS EQUAL TO WHAT IS SHOWN ON THE DRAWING, THE CONTRACTOR IS TO CONTACT THE DESIGN ENGINEER AND JAMBA JUICE'S PROJECT MANAGER FOR APPROVAL. CONTRACTOR IS TO NOTIFY JAMBA JUICE'S PROJECT MANAGER AND DESIGN ENGINEER IN WRITING OF ALL REPLACEMENT ITEMS PRIOR TO CONSTRUCTION. B WHERE EXISTING EQUIPMENT (LIGHTS, DIFFUSERS, TOILETS, ETC.) ARE TO BE REUSED, WHETHER IT IS RELOCATED OR REUSED IN THE EXISTING LOCATION, EXTREME CARE SHALL BE TAKEN TO PREVENT DAMAGE DURING THE RENOVATION OF THE STORE. WHERE DAMAGE OCCURS, THE EQUIPMENT SHALL BE REPLACED TO THE SATISFACTION OF THE ARCHITECT, AT NO ADDITIONAL COST TO THE OWNER. ALL ITEMS TO BE THOROUGHLY CLEANED, IF REQUIRED, PAINTED, AND ANY OTHER MAINTENANCE NEEDED TO BRING EQUIPMENT UP TO LIKE NEW CONDITION. THIS INCLUDED RELAMPING ALL LIGHTS REUSED. C REFER TO MECHANICAL DRAWINGS FOR EXACT SIZE, LOCATION, AND ELECTRICAL REQUIREMENTS FOR ALL MOTORS AND MECHANICAL EQUIPMENT. COORDINATE WITH MECHANICAL CONTRACTOR AND PROVIDE ELECTRICAL CONNECTIONS AS REQUIRED FOR A COMPLETE AND OPERABLE SYSTEM. D ALL NEW POWER AND LIGHTING CONDUITS ON THIS PROJECT SHALL INCLUDE AN INSULATED GREEN EQUIPMENT GROUNDING CONDUCTOR SIZED AS NOTED OR PER NEC WHERE NOT NOTED. THIS GROUNDING CONDUCTOR SHALL BE PROVIDED REGARDLESS OF THE TYPE OF CONDUIT USED. E EXISTING CONDITIONS SHOWN ARE BASED ON AS -BUILT DRAWINGS PROVIDED BY THE OWNER AND LIMITED FIELD VERIFICATION. CONTRACTOR SHALL ADJUST FOR ACTUAL FIELD CONDITIONS AT NO ADDITIONAL EXPENSE TO THE OWNER. Issue Date 7/28/11 Drawn By AQ Appv'd By DAR Revisions Date Description By A A A A A CITYO$TU� AUG 012( PERMIT CEN NLA 111 TER J6.0 VERSION 4 -31 -08 6.0.0 M.E.P. Roof Plan MEP -101 B -6,8 ■' ®® 60/40/2 NEMA 3R ■� B -2,4 4 ®® N 30/30/2 NEMA 3R 3M.E.P. ROOF PLAN SCALE: 1/4" = 1' -0" NORTH REVIEWED FOR CODE COMPLIANCE 41 APPROVED AUG 19 2011 City of Tukwila BUILDING DIVISION Sh,:in r 141 DR DANIEL A. REEVES, P.E. 3100 E. Randol Mill Rd Arlington, TX 76011 (817)633 -4200 FAX (817)633 -4153 Washington License #44016 EXPIRES 0,7 woru6lsepswpd 3100 East Rondo! Mill Road Lrf M o • C° N e o Q) • o o O • m 011 m C • Q 07) KEYED NOTES 0 WALK -IN COOLER CONDENSING UNITS MOUNTED ON ROOF. VERIFY REQUIREMENTS WITH MANUFACTURER PRIOR TO INSTALLATION. ML(1O � GENERAL NOTES cc W 1� J Z Q W2 W V I w z Ow ca mom= a W - �0 ILL CO H cfl V) co W O CLw U CO CO T"" CO 0, —J (1) w J H w PROJECT NUMBER: A "VERIFY IN FIELD" OR "EXISTING" MEANS THE CONTRACTOR IS TO CONFIRM THE ITEM SHOWN ON THE DRAWING (I.E. EQUIPMENT, DUCT, WIRE, ETC.) EXISTS AT THE SITE AND IS IN GOOD WORKING CONDITION. SHOULD THE CONTRACTOR FIND THAT THE EQUIPMENT, DUCT, WIRE, ETC. IS NOT THE EQUAL TO THAT SHOWN ON THE DRAWING, IT IS TO BE REPLACED, IF THE CONTRACTOR HAS ANY QUESTION ABOUT WHETHER IT IS EQUAL TO WHAT IS SHOWN ON THE DRAWING, THE CONTRACTOR IS TO CONTACT THE DESIGN ENGINEER AND JAMBA JUICE'S PROJECT MANAGER FOR APPROVAL. CONTRACTOR IS TO NOTIFY JAMBA JUICE'S PROJECT MANAGER AND DESIGN ENGINEER IN WRITING OF ALL REPLACEMENT ITEMS PRIOR TO CONSTRUCTION. B WHERE EXISTING EQUIPMENT (LIGHTS, DIFFUSERS, TOILETS, ETC.) ARE TO BE REUSED, WHETHER IT IS RELOCATED OR REUSED IN THE EXISTING LOCATION, EXTREME CARE SHALL BE TAKEN TO PREVENT DAMAGE DURING THE RENOVATION OF THE STORE. WHERE DAMAGE OCCURS, THE EQUIPMENT SHALL BE REPLACED TO THE SATISFACTION OF THE ARCHITECT, AT NO ADDITIONAL COST TO THE OWNER. ALL ITEMS TO BE THOROUGHLY CLEANED, IF REQUIRED, PAINTED, AND ANY OTHER MAINTENANCE NEEDED TO BRING EQUIPMENT UP TO LIKE NEW CONDITION. THIS INCLUDED RELAMPING ALL LIGHTS REUSED. C REFER TO MECHANICAL DRAWINGS FOR EXACT SIZE, LOCATION, AND ELECTRICAL REQUIREMENTS FOR ALL MOTORS AND MECHANICAL EQUIPMENT. COORDINATE WITH MECHANICAL CONTRACTOR AND PROVIDE ELECTRICAL CONNECTIONS AS REQUIRED FOR A COMPLETE AND OPERABLE SYSTEM. D ALL NEW POWER AND LIGHTING CONDUITS ON THIS PROJECT SHALL INCLUDE AN INSULATED GREEN EQUIPMENT GROUNDING CONDUCTOR SIZED AS NOTED OR PER NEC WHERE NOT NOTED. THIS GROUNDING CONDUCTOR SHALL BE PROVIDED REGARDLESS OF THE TYPE OF CONDUIT USED. E EXISTING CONDITIONS SHOWN ARE BASED ON AS -BUILT DRAWINGS PROVIDED BY THE OWNER AND LIMITED FIELD VERIFICATION. CONTRACTOR SHALL ADJUST FOR ACTUAL FIELD CONDITIONS AT NO ADDITIONAL EXPENSE TO THE OWNER. Issue Date 7/28/11 Drawn By AQ Appv'd By DAR Revisions Date Description By A A A A A CITYO$TU� AUG 012( PERMIT CEN NLA 111 TER J6.0 VERSION 4 -31 -08 6.0.0 M.E.P. Roof Plan MEP -101