HomeMy WebLinkAboutPermit M11-116 - STARBUCKSSTARBUCKS COFFEE COMPANY 3301 S NORFOLK ST M11-116 City ofkukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206431-3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov MECHANICAL PERMIT Parcel No.: 0323049024 Address: 3301 S NORFOLK ST TUKW Project Name: STARBUCKS COFFEE COMPANY Permit Number: Issue Date: Permit Expires On: M11 -116 10/24/2011 04/21/2012 Owner: Name: ASSOCIATED GROCERS Address: P.O. BOX 3763 , SEATTLE, WA 98124 Contact Person: Name: Address: Email: ERIC HOPP 2401 S UTAH AV S, SUITE 800 , SEATTLE WA 98134 EHOPP @STARBUCKS.COM Contractor: Name: DB GENERAL CONTRACTORS INC Address: 3320 WEST VALLEY HY D -106 , AUBURN WA 98001 Contractor License No: DBGENGC943O9 Phone: 206 -318 -9309 Phone: 253 - 736 -2980 Expiration Date: 09/29/2012 DESCRIPTION OF WORK: INSTALL HVAC PER PLANS /DRAWINGS Value of Mechanical: $20,000.00 Type of Fire Protection: UNKNOWN Electrical Service Provided by: Permit Center Authorized Signature: I hereby certify that I have read and e governing this work will be complied Fees Collected: $428.56 International Mechanical Code Edition: 2009 Date: 1OI `iik d this permit and know the same to be true and correct. All provisions of law and ordinances hether specified herein or not. The granting of this permit does not pres construction or the performan back of this permi Signature: Print N to give authority to violate or cancel the provisions of any other state or local laws regulating uthorized to sign and obtain this mechanical permit and agree to the conditions on the Date: /U Z-41- —1 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -4/10 M11-116 Printed: 10 -24 -2011 PERMIT CONDITIONS Permit No. M1 1-1 16 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional m responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: Readily accessible access to roof mounted equipment is required. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431- 3670). 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IMC -4/10 M11-116 Printed: 10 -24 -2011 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto://www.TukwilaWA.00v Building Permit No. p 9— Mechanical Permit No. V, I (-- 1 L (Q Plumbing/Gas Permit No. Ii1C G I— ( � Public Works Permit No. Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: 3301 S. Norfolk Street Tenant Name: Starbucks Coffee Company Property Owners Name: Sabey Corporation Mailing Address: 12201 Tukwila International Blvd. King Co Assessor's Tax No.: Suite Number: NA Floor: NA New Tenant: J Yes ❑ .. No Seattle City 98168 State Zip CONTACT PERSON — who do we contact when your permit is ready to be issued Name: Eric A. Hopp Mailing Address: 2401 Utah Avenue S. Suite 800 E -Mail Address: ehopp @starbucks.com Day Telephone: (206) 318 -9309 Seattle City Fax Number: wa State 98134 Zip GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: DB Contractors Mailing Address: 3320 W. Valley Hwy. D -106 Aubum City State Zip Person: Jake Hatfield Day Telephone: (206) 251 -5489 E -Mail Address: fake @db- gc.com Fax Number: Contractor Registration Number: DBGENGC94309 Expiration Date: 09/29/2012 98001 ARCHITECT OF RECORD — All plans must be stamped by Architect of Record Company Name: Tony Gale III Mailing Address: 2401 Utah Avenue S. Suite 800 Contact Person: Eric Hopp E -Mail Address: ehopp @starbucks.com Seattle City State Zip Day Telephone: (206) 447 -1575 Fax Number: 98134 ENGINEER OF RECORD — All plans must be stamped by Engineer of Record Company Name: Rensch Engineering Mailing Address: 111 AVE. C, Suite 104 Contact Person: Chris Rensch E -Mail Address: chris.r @renschengineering.com H: WppliationslFomu•Applicanons On Line 12010 Applicetions17.2010 - Permit Applicationdoe Revised: 7.2010 bh Snohomish City State Zip Day Telephone: (360) 863 -6677 Fax Number: 98290 06' '7/1j Page l of 6 MECHANICAL PERMIT INFORMATION - 206 -431 -3670 MECHANICAL CONTRACTOR INFORMATION Company Name: III f 1> 11 eam, i Ci•4i Mailing Address: 33030 1 L )4-ct ' • SL,14 -e 1 0 2 z,14t) Ay (,c)cj %ecc? ;� City State Zip Contact Person: em'S t -1.hIP rl Day Telephone: ZS; - `NS- - 6244 E -Mail Address: leih /-1 —/ QConaC4•s+. Nef Fax Number: 2S3 - 95!$" - 02-05- Contractor Registration Number: I4 b t7 EG / oo B L 7 Expiration Date: 201 y Valuation of Mechanical work (contractor's bid price): $ 24� A Scope of Work (please provide detailed information): /rr s44 / /in, WV l4C Pen- plan 1//.)e4 ,,.l&7 S Use: Residential: Commercial: Fuel Type: Electric New ....1.......--Replacement .... ❑ New.... Q Replacement .... ❑ Gas.... ❑ Other: Indicate type of mechanical work being installed and the quantity below: Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: 0 -3 HP /100,000 BTU Qty Furnace <I00K BTU Air Handling Unit >10,000 CFM Fire Damper Furnace>100K BTU Evaporator Cooler Diffuser s- 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat _ HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood /Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM 2- Incinerator - Comm/Ind H: WppIicationstFomts•Applieations On Line12010 Applicationi\7 -2010 • Pemsit Applieation.doe Revised. 7-2010 en Page 4 of 6 u/4 1 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (curreut edition). Plumbing Permit The Building Of <' in writing grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested use demonstrated. Section 103.4.3 Uuifonn Plumbing Code (current edition). 1 HEREBY C ' TIFY PENALTY OF PERJU BUILDING Signature: XAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER TATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. Print Name: Mailing Address: Telephone: 6 ' 6oi - I( ( Date Application Accepted: 81 I Date Application Expires: Staff Initials: tl MpplicatiotsTorms•Applieations On Line\2010 Applieations\7-2010 • Penn it Application.doc Rcvned: 7 -2010 bb Page 6of6 Ci, of Tukwila. • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: //www.ci.tukwila.wa.us SET RECEIPT RECEIPT NO: R11 -02326 Initials: WER Payment Date: 10/24/2011 User ID: 1655 Total Payment: 721.38 Payee: DB GENERAL CONTRACTORS, JEREMY HABERMAN SET ID: 1024 SET NAME: STARBUCKS SET TRANSACTIONS: Set Member M11 -116 PG11 -124 TOTAL: Amount 342.85 378.53 342.85 TRANSACTION LIST: Type Method Description Amount Payment Credit C VISA 721.38 TOTAL: 721.38 ACCOUNT ITEM LIST: Description Account Code Current Pmts MECHANICAL - NONRES PLAN CHECK - NONRES PLUMBING - NONRES 000.322.102.00.0 000.345.830 000.322.103.00.0 342.85 6.83 371.70 TOTAL: 721.38 SET RECEIPT RECEIPT NO: R11 -01774 Initials: WER Payment Date: 08/16/2011 User ID: 1655 Total Payment: 958.23 Payee: DALE SPENCER SET ID: 08 -16 -11 SET NAME: STARBUCKS SET TRANSACTIONS: Set Member D11 -282 EL11 -0763 M11 -116 PG11 -124 TOTAL: Amount 655.79 130.63 85.71 86.10 655.79 TRANSACTION LIST: Type Method Description Amount Payment Credit C MC 958.23 TOTAL: 958.23 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES 000.345.832.00.0 PLAN CHECK - NONRES 000.345.830 130.63 827.60 TOTAL: 958.23 7 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 g (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: ST�R8 2 /C'.l S Type of Inspection: ,r7 Am _ Address: .3 36 l 5 / / y_ Date Called: Special Instructions: • Date Wanted: - a.m. 13 -// r. Requester: Phone No: • 0753 —A7C, — ‘417S Approved per applicable codes. D Corrections required prior to approval. COMMENTS: tor ,.0);-/ a r%F,4/7✓/ Date: chel ri R y PECTION FEE REQUIRED. rior to/text inspection. fee must be p '9 at 6300 Southcenter Blvd., ite 100. Call to schedule reinspection. J. • INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter BIvd:, #100, Tukwila: WA 98188 V.. (206) 431 =3670 Permit Inspection Request Line (206) 431 -2451 I/Vi l j -11 c .. Project: • S 1 it1 i -A5LA. V.0 Type of Inspection: 1-- 1 A.)11 t... (I) R'' 4i -, Address: :3 a.O ( t.L Date Called: Special Instructions: . . p 0114-0 t Date Wanted:. . A Requester: Phone No: 01.00r571 -- Ise j t3Approved per applicable codes. aCorrections required prior to approval. — COMMENTS: (I) R'' 4i -, -11A ,Dr167-¢ ..1-A/s7t /..- Al, /Nit/ \ ..0.-........, / \ , LI REECTION FEE REQUIRE)). Pri r to next inspection, fee must be p ii at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. I •+ INSPECTION INSPECTION RECORD Retain a copy with permit •INSPECTION NO. PERMIT NO. • ' CITY OF' TUKWILA BUILDING DIVISION '630.0 Southcenter 'Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 e S • • S' ;• Y Project: . ,;.5 W 1 f Typg- of�inspecti n: 1`1 Ai u4A �'r . Addres "s: Oat it r 1 Date Called: ., _ J' ( Ake-d - • ft4 u 6 to _i . Special Instructions: ' • • • Date Wanted:. Z ~� ^6, .-`"a :m p- P.m. Requester: Phone rN�o: �j _/� / twit - 13 / Apptnved Per applicable codes. Corrections required prior to approv COMMENTS: �'r �� ,_ / _t ... ., _ J' ( Ake-d - • ft4 u 6 to _i . .. ke- -/i `1-3 t A .P • : loe.t.,,N. "--t—es-r . 0 s-roi Apia 54 '[" .cT a J c/d - ► g A t I c - fl),- / L i J6 - :60( - `crn.rL /.4 n 4 Instor: Date: 1 Z f REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be . • paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. pEI:;T 4 If • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M11 -116 DATE: 08 -16 -11 PROJECT NAME: STARBUCKS COFFEE COMPANY SITE ADDRESS: 3301_S NORFOLK ST X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS. 4ading/tvision Public Works RYA NIP oit.?fiI • I� Fire Prevention Structural Planning Division ❑ Permit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete n DUE DATE: 08-18-11 Not Applicable Comments: :Permit Center Use Only . . INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 09-15 -11 Approved ❑ Approved with Conditions Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: . Pei»iitCenter Use Only. . CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 Contractors or Tradespeople ter Friendly Page s General /Specialty Contractor A business registered as a construction contractor with LEI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name DB GENERAL CONTRACTORS INC UBI No. 602650709 Phone 2537362980 Status Active Address 3320 West Valley Hwy D -106 License No. DBGENGC94309 Suite /Apt. License Type Construction Contractor City Auburn Effective Date 9/29/2006 State WA Expiration Date 9/29/2012 Zip 98001 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Business Owner Information Name Role Effective Date Expiration Date BEDNARIK, DEWAINE President 09/29/2006 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 DEVELOPERS SURETY & INDEM CO 743855C 09/28/2006 Until Cancelled $12,000.00 09/29/2006 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 5 Nationwide Mutual Ins Co ACP7505276908 09/28/2011 09/28/2012 $1,000,000.00 09/27/2011 4 Continental Western Ins Co CWP26515525 09/28/2010 09/28/2011 $1,000,000.00 09/22/2010 3 Continental Western Ins Co CWP265155 09/28/2008 09/28/2010 $1,000,000.00 09/10/2009 2 CONTINENTAL WESTERN CWP26515521 09/28/2007 09/28/2008 $1,000,000.0009 /28/2007 1 CONTINENTAL CAS CO CWP265155 09/28/2006 09/28/2007 $1,000,000.00 09/29/2006 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https:// fortress .wa.gov /lni/bbip/Print.aspx 10/24/2011 HVAC SYMBOLS LEGEND HVAC ABBREVIATIONS LANDLORD REQUIREMENTS GENERAL HVAC NOTES Description AFF ABOVE FINISHED FLOOR 11 LANDLORD AHJ AU1}IQRIIIES HAVING JURISDICTION LV LOW VOLTAGE APPROX APPROXIMATE MAX MAXIMUM BLDG BUILDING MECH MECHANICAL MC MECHANICAL CONTRACTOR CLG CEILING MEP MECHANICAL ELECTRICAL CONST CONSTRUCTION AND PLUMBING CD CEILING DIFFUSER MFG MANUFACTURER CO2 CARBON DIOXIDE MIN MINIMUM DEG DEGREES NTS NOT TO SCALE DTI. DETAIL DM STARBUCKS DESIGN MANAGER OSA OUTSIDE AIR DN DOWN DWG(S) DRAiMNG(S) PM PROJECT MANAGER Eq EACH REF REFERENCE EC ELECTRICAL CONTRACTOR RE 'D REQUIRED ELEC ELECTRICAL Q() () EM EMERGENCY REV REVISION f REVISION RG RETURN GRILLE ((E) OR (EX) EXTERIOR RT ROOFTOP EG EXHAUST GRILLE SHT SHEET SPECS SPECIFICATION(S) F&I FURNISH & INSTALL SF SQUARE FEET FLR FLOOR SS STAINLESS STEEL FT FOOT /FEET TEMP TEMPORARY G GAS PIPING TYP TYPICAL GC GENERAL CONTRACTOR LINO UNLESS NOTED OTHERWISE HR HOUR WH WATER HEATER HVAC HEATING, VENTILATION, WSHP WATER SOURCE HEAT PUMP AIR CONDITIONING PRIOR TO BID: THE CONTRACTOR SHALL COORDINATE WITH 0 LANDLORD BUILDING OWNER FOR ANY CONSTRUCTION / REQUIREMENTS/ SPECIFICATIONS. REQUIREMENTS SPECIFICATIONS. W LANDLORD BUILDING OWNER DOES HAVE REQUIREMENTS, CONTRACTOR SHALL BECOME COMPLETELY FAMILIAR WITH REQUIREMENTS /SPECIFICATIONS AND ADHERE TO THEM. WHERE LANDLORD /BUILDING OWNER REQUIREMENTS ARE MORE STRINGENT THAN SHOWN IN THESE PLANS (IN THE OPINION OF THE ENGINEER), LANDLORD /BUILDING OWNER REQUIREMENTS SHALL GOVERN. © LANDLORD'S SCOPE OF WORK: THE LANDLORD SHALL COMPLETE THE SCOPE . 1 . ALL IS NEW UNLESS OTHERWISE NOTED. 2. MC SHALL VERIFY THE LOCATION OF ALL EXISTING DUCTWORK, UNITS AND MISC. PRIOR TO CONSTRUCTION AND BE RESPONSIBLE FOR SITE INVESTIGATION PRIOR TO START OF WORK TO REVEAL. THE FULL SCOPE OF WORK, IN ADDITION THE MC SHAD. THOROUGHLY EXAMINE ALL AREAS WHERE EQUIPMENT, DUCTING, AND HVAC UNITS WILL BE INSTALLED AND WiLL REPORT ANY CONDITION THAT PREVENTS THE PROPER INSTALLATION OF THE HVAC WORK. 3. MC SHALL COORDINATE WITH THE GC TO PATCH AND REPAIR ALL EXISTING WALLS, FLOORS, CEILINGS OR OTHER SURFACES IDENTIFIED TO REMAIN THAT MAY BECOME DAMAGED DURING THE COURSE OF WORK. 4. DRAWINGS ARE DIAGRAMMATIC AND INDICATE GENERAL INTENT OR ARRANGEMENT OF SYSTEMS }. F&I ALL COMPONENTS NEEDED WHETHER INDICATED OR NOT TO EM(S DE A COMPLETE AND OPERATING SYSTEM. 5. OTHER TRADES, AND NOTIFY DIMENSIONS, B S IOM LOFDIANY DISCREPANCIES E QPRIOR TTO PROCEEDING WITH THE WORK. ALL DIMENSIONS ARE TO THE FACE OF THE FINISHED SURFACE UNLESS NOTED OTHERWISE• ALL DIMENSIONS TO BE TAKEN FROM FROM ACTUAL BUILDING DIMENSIONS. 6. THE MC SHALL COORDINATE HVAC WORK IMTH OTHER TRADES. THE ARCHITECTURAL DRAWINGS SHALL TAKE PRECEDENCE OVER ALL OTHER DRAWINGS. SEE ARCH. DRAWINGS FOR DIMENSIONED DIFFUSER LOCATIONS AND MOUNTING HEIGHTS WHERE EXPOSED, 7. NOTE NOT USED. 8. ALL HVAC DUCTWORK AND EQUIPMENT SHALL BE SUPPORTED FROM STRUCTURE (CONFIRM) AND NOT FROM OTHER DUCTS, PIPING, CONDUITS OR CEILING SUPPORTS. 9. NEW DUCTWORK AND EQUIPMENT SHALL NOT BE INSTALLED WHERE IT OBSTRUCTS ANY EXISTING OR NEW AREAS THAT REQUIRE ACCESS. NI TYPICAL SUPPLY DUCT UP /DON i DUCT HEATER INDICATES UNLINED 12" x 8" 0•D. SHEETMETAL = 1ST FIGURE = SIDE SHOWN, ND FIGURE =SIDE NOT SHOWN) " INDICATED 14" x 10 O.D. SHEETMETAL W/ 1 SOUNDUNER (U.N.O.), 12 x 8 I.D. NET 12 X 8 ijo TYPICAL RETURN DUCT UP/DN D N . . , = ��� ;; 53 MANUAL VOLUME DAMPER BACK DRAFT DAMPER BAROMETRIC DAMPER DUCT SMOKE DETECTOR MOTORIZED DAMPER --�-- -�-- 12 X 8 --�- '• TURNING VANES rrojecc Haaress: 3301 S. Norfolk St. Tukwila, WA 98168 ' FLEXIBLE CONNECTION I 4.40 EQUIPMENT DESIGNATION .; T THERMOSTAT C CO2 SENSOR Ill COMBINATION SMOKE AND FIRE DAMPER SPIN -IN TAKE -OFF AND Iii VOLUME DAMPER ,, ' t.• ' V FLEXIBLE DUCT OF WORK AS AGREED UPON WITH STARBUCKS IN THE LANDLORD'S WORK LETTER. WHERE LANDLORD'S SCOPE OF WORK IS INDICATED /CLARIFIED IN THESE PLANS, IT SHALL BE FURNISHED AND 1NSTALLED AS SPECIFIED /INDICATED. ANY QUESTINS AND /OR DISCREPANCIES SHALL BE BROUGHT TO STARBUCKS ATTENTION FOR CLARIFICATION. 120 -� NECK SIZE CD-1E400'4 + SENSOR UNDERCUT DOOR r� DESIGN CFM (WHERE APPLICABLE). RETURN AIR = OCCUPIED/UNOCCUPIED Q SUPPLY AIR ARROW DIFFUSER TYPE, REF, SCHEDULE - --.r.. RETURN /EXHAUST AIR ARROW MECHANICAL SHEET INDEX E ARROWS -` P-- -°--®- SEPARATE PERMIT REQUIRED FOR: i ' INDICATE DIRECTION AIR M -001 MECHANICAL SPECIFICATIONS M -111 MECHANICAL HVAC PLAN M -112 UPPER LEVEL HVAC PLAN ■ Mechanical \ \- \ CEILING RETURN/EXHAUST GRILLE Electrical Plumbing l' Gas Piping City of Tukwila BUILDING DIVISION M3,0 DETAIL MARK MECHANICAL SPECIFICATIONS AiR HANDLING EQUIP. & MATERIALS CONTROLS & OPERATION LEED SYSTEM COMMISSIONING DUCTWORK & ACCESSORIES GENERAL SPECIFICATION NOTES AIR HANDLING UNITS AIR HANDLING UNITS SHALL BE AS SPECIFIED IN THE MECH. SCHEDULE AND SHALL ' WHERE BE FURNISHED AND INSTALLED PER THE LANDLORDS WORKLETTER OR GC E . THE MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE THERE IS NO VWING EITER E FOR COORDINATING DELIVERY, PROVIDING COMPLETE INSTALLATION INCLUDING CURBS, PIPES, VIBRATION ISOLATION AND NECESSARY ACCESSORIES, AS WELL AS PROVIDING WARRANTY, FOR COORDINATION OF DELIVERY AND SPECIFICATION A ACCOUNTS, DALLAS, TEXAS 800 367- -6285 CARRIER CONTACT LENNOk NATIONAL CCOU ►DLL ( CORPORATION CUSTOMER RELATIONS, SYRACUSE, NEW YORK (800)227-7437, OR TRANE IN REDMOND, WA AT (425) 643 -4310. FILTERS PROVIDE THREE 3 SETS OF 2" MERV 6 PLEATED DISPOSABLE FILTERS FOR EACH j UNIT. USE ONE SET UNTIL COMPLETION OF CONSTRUCTION. INSTALL ONE SET AT COMPLETION OF CONSTRUCTION AND DELIVER ONE SET OF FILTERS TO STARBUCKS LABELED TO DENOTE THEIR RESPECTIVE AIR HANDLING UNIT. FILTERS TO BE FARR, OR SIMILAR, EXHAUST FANS EXHAUST FAN(S) SHALL BE AS SCHEDULED AND SHALL BE FURNISHED & INSTALLED PER THE LANDLORD 5 WORKLETTER OR GC WHERE THERE IS NO WORKLETTER. THE MECHANICAL IS RESPONSIBLE FOR COORDINATING DISCHARGE LOCATION WITH NEW AND EXISTING VENTS AND INTAKES, PROVIDING O DIT CO DISCHARGE INSTALLATION INCLUDING DUCTWORK FROM RESTROOM GRILLE TO UNIT AND NECESSARY ACCESSORIES, AND PROVIDING WARRANTY. COORDINATE ALL REQUIREMENTS WITH OTHER CONTRACTORS. CONTROL WRING THE MECHANICAL CONTRACTOR SHALL PROVIDE ALL CONTROL WIRING IN CONDUIT NECESSARY FOR THE COMPLETE AND PROPER OPERATING TEMPERATURE CONTROL SYSTEM INCLUDING ALL MODES OF OPERATION AND INTERLOCKS. THERMOSTAT THERMOSTAT (S) SHALL BE HONEYWELL PROGRAMMABLE T -7351F WITH REMOTE ROOM SENSOR(S) 17770 FURNISHED AND INSTALLED PER SCHEDULE. ONE THERMOSTAT AND SENSOR SHALL BE PROVIDED FOR EACH AIR HANDLING UNIT. MOUNT THERMOSTAT(S) AND ROOM SENSOR(S) - IN LOCATIONS INDICATED ON DRAWINGS, MECHANICAL CONTRACTOR SHALL PROVIDE THERMOSTAT AND ROOM SENSOR IDENTIFICATION LABELS WITH 1/8" HIGH BLACK LETTERS PRINTED ON �� " " DURABLE CLEAR STICKER LABELS (E G. RTU -1 : WORKROOM AND RTU -2 • CUSTOMER AREA") . THERMOSTAT SETUP INSTRUCTIONS PROVIDE THE FOLLOWING SETUP: 1. FOLLOW INSTRUCTIONS IN THE MANUAL WHICH COMES WITH THE THERMOSTAT. ADDITIONAL INFORMATION AVAILABLE FROM HONEYWELL INC., HOME AND BUILDING CONTROL DIVISION. 2. SET DIP SWITCHES AND JUMPERS AS FOLLOWS: A DEGREES F DISPLAY B 12 HOUR CLOCK C CONTINUOUS FAN OPERATION IN OCCUPIED MODE D DISABLE KEYBOARD PROGRAMMING E CUT JUMPER IF UNIT IS A HEAT PUMP 3. SET CLOCK AND DAY. 4. SET TO DISPLAY CURRENT TEMPERATURE. CONTRACTOR RESPONSIBILITIES FOR BUILDING COMMISSIONING SHEETMETAL ETAL DUCTWORK ALL DUCTWORK SHALL BE RIGID SHEETMETAL CONSTRUCTED FROM GALVANIZED SHEET STEEL iN ACCORDANCE WITH SMACNA LOW VELOCITY DUCT CONSTRUCTION STANDARDS. FIBERGLASS DUCTBOARD IS NOT ALLOWED. ALL EXPOSED DUCTWORK SHALL BE ROUND, FLAT OVAL, SPIRAL, OR RECTANGULAR LOCK -SEAM TYPE, AS SHOWN ON HVAC PLAN. ASSEMBLE AND INSTALL DUCTWORK IN ACCORDANCE WITH RECOGNIZED INDUSTRY PRACTICE FOR ACHIEVING AIR TIGHT (5% LEAKAGE) AND NOISELESS N4 OBJECTIONABLE NOISE) SYSTEMS, CAPABLE OF PERFORMING EACH INDICATED SERVICE. FURNISH ALL REQUIRED DAMPERS TRANSITIONS CONNECTIONS OPERATING SYSTEM. NO OTHER ' ARIATION EOF DUCT CONFIGURATION ROR SIZES WILL BE PERMITTED EXCEPT BY PERMISSION FROM THE ENGINEER. FLEXIBLE DUCTWORK FLEXIBLE DUCT WORK SHALL ONLY BE INSTALLED AS SHOWN IN PLAN, FLEXIBLE DUCTWORK SHALL BE PULLED TAUT AND APPROPRIATELY FASTENED TO RIGID BRANCH DUCT & DIFFUSER. BENDS SHALL BE MINIMIZED AND WHERE NEEDED BE A FULL RADIUS BEND. SUPPORT BANDS SHALL BE INSTALLED SO AS TO NOT CRIMP FLEX DUCT. FLEXIBLE DUCTWORK SHALL BE UL 181 LISTED AS A CLASS 1 AIR DUCT. DUCT SE ANT SEAL ALL LONGITUDINAL AND TRANSVERSE JOINTS WITH A NON - HARDENING, NONMIGRATING MASTIC OR LIQUID ELASTIC SEALANT OF A TYPE RECOMMENDED BY THE MANUFACTURER FOR SEALING JOINTS AND SEAMS IN SHEET METAL DUCTWORK. COVER ALL FIELD JOINTS, JOINTS AROUND SPiN -IN FITTINGS AND FASTENING SCREWS WITH MASTIC, SUPPORTS PROVIDE HOT - DIPPED GALVANIZED STEEL, FASTENERS, ANCHORS. RODS, STRAPS, TRIM, AND ANGLES FOR SUPPORT OF DUCTWORK, DAMPERS FURNISH AND INSTALL OPPOSED- BLADE, MULTI -LEAF VOLUME CONTROL DAMPERS WHERE INDICATED ON DRAWINGS AND AT POINTS ON LOW PRESSURE SUPPLY, RETURN AND EXHAUST DUCTS WHERE BRANCHES ARE TAKEN FROM LARGER DUCTS. PROVIDE UL LISTED FIRE DAMPERS AND/OR COMBINATION FIRE SMOKE DAMPERS WHERE NEEDED AND IN ACCORDANCE WITH NFPA AND LOCAL CODES. COORDINATE WITH GC AND ELECTRICAL FOR FIRE ALARM INTERFACE AND POWER. PROVIDE CONVENIENTLY LOCATED ACCESS DOORS OF AMPLE SIZE AND QUANTITY FOR SERVICING THE DAMPERS. WHERE REQUIRED BY CODE OR AHJ, F &I MOTORIZED DAMPERS FOR OSA (NOT NECESSARILY SHOWN). DAMPER AIR LEAKAGE MOTORIZED AND NON- MOTORIZED DAMPERS USED FOR OUTSIDE AIR INTAKES, EXHAUST & RETURN OUTLETS (INCLUDING THOSE WITHIN HVAC EQUIPMENT) SHALL HAVE A MAXIMUM AIR LEAKAGE VALUE PER THE ENERGY CODE WHEN TESTED PER AMCA STD 500 GRILLES, REGISTERS & DIFFUSERS GRILLES, REGISTERS AND DIFFUSERS SHALL BE MANUFACTURED BY TITUS AND SHALL BE FURNISHED AND INSTALLED BY THE MECHANICAL CONTRACTOR. INDICATED ON NOTE: " "MECHANICAL CONTRACTOR MEANS MECHANICAL CONTRACTOR WHEN REFERENCED ANYWHERE IN THE MECHANICAL CONSTRUCTION DOCUMENTS UNLESS WORK AND EQUIPMENT HAS BEEN COORDINATED BETWEEN THE MECFIANiCAL AND GENERAL CONTRACTORS TO BE PROVIDED BY OTHERS. "NEEDED ", "PROVIDE ", AND "INSTALL" MEANS ALL ITEMS CALLED OUT IN THE CONTRACT DOCUMENTS AND ANY ADDITIONAL ITEMS NOT CALLED OUT BUT REQUIRED TO MAKE A COMPLETE AND OPERATIONAL SYSTEM. SCOPE THE INTENT OF THE SPECIFICATIONS AND THE DRAWINGS IS TO PROVIDE A COMPLETE AND FULLY OPERATIONAL MECHANICAL SYSTEM, THE MECHANICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL LABOR, MATERIAL AND EQUIPMENT NECESSARY TO COMPLETE THE MECHANICAL WORK. PERMITS AND FEES THE MECHANICAL CONTRACTOR :SHALL PROCURE AND PAY FOR ALL PERMITS, FEES AND INSPECTIONS NECESSARY TO COMPLETE THE - MECHANICAL SCOPE OF WORK. WARRANTY THE MECHANICAL CONTRACTOR SHALL UNCONDITIONALLY WARRANT ALL WORK TO BE FREE OF DEFECTS IN MATERIAL AND WORKMANSHIP FOR A PERIOD OF ONE (1) YEAR FROM THE DATE OF FINAL ACCEPTANCE BY ARCHITECT AND WILL REPAIR OR REPLACE ANY DEFECTIVE WORK PROMPTLY AND WITHOUT CHARGE AND RESTORE ANY OTHER EXISTING WORK! DAMAGED IN THE COURSE OF REPAIRING DEFECTIVE MATERIALS AND WORKMANSHIP, CODES PERFORM ALL WORK ITV ACCORDANCE WiTH THE CURRENT MECHANICAL CODE, STATE AND LOCAL CODES /ORDINANCES AND AHJ. ALL WORK SHALL ALSO BE IN COMPLIANCE WITH BUILDING OWNERS CRITERIA. IN CASE OF CONFLICT BETWEEN THE DRAWINGS, SPECIFICATIONS, CODES, ORDINANCES, AND AHJ, THE MOST STRINGENT STANDARD (IN THE OPINION OF THE ENGINEER) SHALL APPLY. THE MECHANICAL CONTRACTOR SHALL SATISFY CODE, AHJ, DRAWINGS, AND SPECIFICATIONS AS A MINIMUM STANDARD WITHOUT ANY EXTRA COST, STANDARDS EQUIPMENT AND MATERIALS SHALL CONFORM WITH APPROPRIATE PROVISIONS OF ARL, ASME, ASTM, UL, NEMA, ANSi, SMACNA, ASHRAE, NFPA, OTHER APPLICABLE AGENCIES AND AHJ AS APPLICABLE TO EACH INDIVIDUAL UNIT OR ASSEMBLY. CONTRA%T% SHALL PROVIDE SUPPORT AND WORK AS SPECIFIED, NEEDED AND CONDUCT AND FACILITATE STARBUCKS STAFF BUILDING COMMISSIONING EFFORTS. THIS WORK WILL BE COMPRISED OF THREE DISTINCT EFFORTS: 1 1) SUPPORT STARBUCKS COMMISSIONING AGENT (CXA) DURING INSTALLATION VERIFICATION AND CORRECT DISCLOSED DEFICIENCIES; 2) PERFORM TESTING, ADJUSTING, BALANCING AND SYSTEM STARTUP AND SUPPORT FUNCTIONAL PERFORMANCE TESTING BY STARBUCKS CXA; 3 CORRECT DEFICIENCIES DISCLOSED BY PERFORM AANDEPROVIDENTHE FOLLOWNGD SUBMIT REPORTS. CONTRACTOR SHALL A. SYSTEMS SUBJECT TO COMMISSIONING MAY INCLUDE, BUT ARE NOT LIMITED TO, A. HVAC SYSTEMS, ROOFTOP UNITS, EXHAUST DOMESTIC HOT WATER GENERATION, , FANS, HVAC CONTROLS, LIGHTING CONTROLS, AIR CURTAINS, BUILT -1N REFRIGERATION EQUIPMENT, AND RENEWABLE ENERGY SYSTEMS. B. CONTRACTORex SHALL INCLUDE COMMISSIONING ACTIVITIES IN PROJECT SCHEDULE AND SHOW INTERVALS FOR PERFORMANCE OF WORK FOR WHICH CONTRACTOR IS RESPONSIBLE AND INTERVALS FOR WORK PERFORMED BY STARBUCKS CXA. CONTRACTOR SHALL SHOW RESOURCES FOR PERFORMING ALL WORK RELATED TO COMMISSIONING ACTIVITIES ON A UNE ITEM IN THE SCHEDULE OF VALUES. C. CONTRACTOR SHALL INSTALL EQUIPMENT IN ACCORDANCE WITH THE MANUFACTURER'S REQUIREMENTS AND ALL CONTRACT DOCUMENTS. ENSURE THAT ALL EQUIPMENT IS INSTALLED TOTALLY COMPLETE, AND ACCESSIBLE TO STARBUCKS CXA FOR INSTALLATIN VERIFICATION AND FUNCTIONAL PERFORMANCE TESTING PRIOR TO THE SCHEDULED START OF INSTALLATION VERIFICATION. D. INSTALLATIN VERIFICATION SHALL BE PERFORMED BY STARBUCKS' CXA. CONTRACTOR SHALL SUPPORT STARBUCKS CXA INSTALLATION VERIFICATION EFFORTS AS NECESSARY. PROVIDE ALL ACCESS AND EQUIPMENT NECESSARY FOR STARBUCKS STAFF TO VERIFY THAT THE EQUIPMENT IS INSTALLED CORRECTLY. E. CONTRACTOR SHALL BE READILY AVAILABLE DURING INSTALLATION VERIFICATION TO CORRECT ANY DEFICIENCIES OR DEFECTS DISCLOSED BY THE INSTALLATION VERIFICATION PROCESS. CORRECTIONS SHALL BE MADE IN A TIMELY MANNER WITHOUT DISRUPTION OF THE CONSTRUCTION SCHEDULE. F. ALL HVAC EQUIPMENT SHALL BE TESTED, ADJUSTED AND BALANCED BY THE CONTRACTOR'S TESTING, ADJUSTING AND BALANCE AGENT (SEE TESTING, ADJUSTING AND BALANCING AFTER THE SYSTEM iS VERIFIED TO BE COMPLETE AND CORRECT BY STARBUCKS CXA, IN ACCORDANCE WITH THE REQUIREMENTS OF THESE DOCUMENTS, ALL HVAC CONTROL SYSTEMS SHALL BE TESTED TO ENSURE THAT CONTROL DEVICES, COMPONENTS, EQUIPMENT AND SYSTEMS ARE CALIBRATED, ADJUSTED AND OPERATE iN ACCORDANCE WITH THESE PLANS AND SPECIFICATIONS. SEQUENCES OF OPERATION SHALL BE TESTED TO ENSURE THAT THEY OPERATE IN ACCORDANCE WITH THE CONTRACT REQUIREMENTS. DELIVERABLES: PRELIMINARY, WRITTEN TESTING AND AIR BALANCE REPORT CONFORMING TO THE REQUIREMENTS SPECIFIED HEREIN, DOCUMENTING THE INFORMATION SPECIFIED, ETC, TO THE STARBUCKS CXA IMMEDIATELY UPON G. CONTRACTOR SHALL INFORM STARBUCKS CXA WHEN EQUIPMENT IS READY FOR FUNCTIONAL PERFORMANCE TESTING. ALL EQUIPMENT SHALL BE READY FOR FUNCTIONAL PERFORMANCE TESTING PRIOR TO STARTING TESTING. CONTRACTOR SHALL OPERATE EQUIPMENT FOR STARBUCKS CXA AND VERIFY BY DEMONSTRATION THE CORRECT OPERATION OF EQUIPMENT, RESPONSE OF SENSORS, AND PROPER EXECUTION OF HVAC CONTROL AND LIGHTING SEQUENCES; INCLUDING BUT NOT LIMITED T0, AIR MOVEMENT, TEMPERATURE, SOUND, AND CONTROL RESPONSE. PROVIDE ANY SECURITY ACCESS HARDWARE SOFTWARE, OR OTHER SUPPORT AS NEEDED FOR THE STARBUCKS CXA TO EFFICIENTLY WITNESS AND DOCUMENT ALL EQUIPMENT TESTING. STARBUCKS CXA WILL RECORD THE EQUIPMENT" OPERATION AND RESPONSE TO TESTING SEQUENCES AND PREPARE A LIST OF ANY DEFICIENCIES DISCLOSED BY THE FUNCTIONAL PERFORMANCE TESTS FOR CORRECTION BY THE CONTRACTOR. EQUIPMENT INCLUDES, BUT IS NOT LIMITED T0, AIR HANDLING UNITS, LIGHTING CONTROLS, ETC. - DEUVERABLES: PROVIDE COMPLETED COPIES OF ALL START UP REPORTS, FILLED OUT ON THE MANUFACTURERS' FORMS, TO THE STARBUCKS CXA. H. CONTRACTOR iS RESPONSIBLE FOR CORRECTING ANY ISSUES OR DEFICIENCIES DISCLOSED DURING THE FUNCTIONAL PERFORMANCE TESTING PROCESS. CORRECTIONS SHOULD BE MADE IN A TIMELY MANNER WITHOUT DISRUPTION TO THE SYSTEM AND CONSTRUCTION SCHEDULE. 1. CONTRACTOR SHALL BE READILY AVAILABLE FOR ANY RE- TESTING OF EQUIPMENT DEEMED NECESSARY BY STARBUCKS CXA DURING INSTALLATION VERIFICATION FUNCTIONAL CORRECTINGANY PERFORMANCE SUES OR DEFICIENCIES FOUND IN THE W SYSTEM DURING A Y AND ALL RE- TESTING. CORRECTIONS SHOULD BE MADE IN A TIMELY MANNER WITHOUT DISRUPTION TO THE SYSTEM AND CONSTRUCTION SCHEDULE. DELIVERABLES: FINAL BALANCE REPORT, DEFICIENCIES UST NOTING CORRECTIVE ACTIONS PERFORMED BY CONTRACTOR IN RESPONSE TO INSTALLATION VERIFICATION AND FUNCTIONAL PERFORMANCE TEST RESULTS, J. CONSTRUCTION AND POST CONSTRUCTION TESTING: ADDITIONAL TESTING MAY BE REQUIRED BY LEED AND OTHER PROCESSES THAT MAY OCCUR OUT OF SEQUENCE WITH COMMISSIONING SERVICE. CONTRACTOR SHAD. CONDUCT, DOCUMENT, SUPPORT AND SCHEDULE THIS TESTING AS DIRECTED BY STARBUCKS CXA. ADJUSTING BALANCING TESTING ' ' 5. SET OCCUPIED START TIME AT 1 %2 HOUR BEFORE OPENING, SET UNOCCUPIED START TIME AT 1 /2 HOUR AFTER CLOSING. VERIFY MECHANICAL CONTRACTOR OR AN INDEPENDENT AIR BALANCE CONTRACTOR (HIRED BY MECHANICAL CONTRACTOR) SHALL ACCURATELY BALANCE THE AIR & HYDRONIC AWHERE APPLICABLE) SYSTEMS TO PROVIDE AIR & WATER QUANTITIES (WHERE PPLICABLE) INDICATED ON THE DRAWINGS AND IN THIS SPECIFICATION. WHERE QUANTITIES ARE NOT INDICATED BALANCE PER INDUSTRY STANDARD TO PROVIDE A PROPERLY WORKING SYSTEM. OPERATE AUTOMATIC CONTROLS SYSTEM AND VERIFY SET POINTS, A NEBB OR AABE CERTIFIED SUPERVISOR SHALL BE IN CHARGE OF WORK. SUBMIT TWO (2) COPIES OF THE BALANCE REPORT TO THE ENGINEER FOR APPROVAL. INCLUD A COPY OF THE BALANCE REPORT AS APPROVED BY THE ENGINEER WITH APPLICATION FOR FINAL CONTRACT PAYMENT, �IL� �S�PY HOURS WITH STORE MANAGER OR CONSTRUCTION MANAGER, 6. SET POINTS SHALL BE AS FOLLOWS: OCCUPIED UNOCCUPIED HEATING 68 deg F 60 deg F COOLING 73 deg F 80 deg F 7. SET UN- OCCUPIED OVER -RIDE TO 3 HOURS. 8. SET OCCUPIED OVERRIDE FUNCTION TO PROVIDE THE FOLLOWING SET POINT OVERRIDES: HEATING +2de F COOLING -2deg F EXHAUST FANS RESTROOM EXHAUST FANS) TO BE OPERATED IN CONJUNCTION WITH STORE HOURS {UNLESS OTHERWISE NOTED APPROVED). FAN TO BE CONTROLLED BY TIMECLOCK WORD. W/ ELEC.), ( THE MECHANICAL CONTRACTOR SHALL R DE ALL MISCELLANEOUS IITEMSHEDULES. NECESSARY FOR A COMPLETE AND PROPER INSTALLATION IN THE TYPE OF WALLS AND CEILINGS USED IN THIS PROJECT. THERMAL INSULATION RgIrISEOVISUMEVEtilialajLt01°M N WITH AN INTEGRAL VAPOR BAR RIER EET LOCAL STATE ENERGY CODE, AND A.H.J. REQUIREMENTS, PROVIDE INSULATION ON .EXHAUST AND OUTSIDE AIR DUCTS, AND ON CONCEALED PORTIONS OF SUPPLY AND RETURN AIR DUCTS DO NOT INSULATE EXPOSED DUCTWORK WITHIN THE SPACE (UNLESS REQUIRED BY A.H.J,) AND AND PORTIONS OF DUCTWORK THAT ARE INTERNALLY LINED, THERMAL INSULATION TO COMPLY WITH AN NFPA FLAME SPREAD OF 25 OR LESS, AND SMOKE DEVELOPED NO GREATER THAN 50. INSULATE DUCTWORK ON ROOF PER CODE. IF ANY OF THE ABOVE IS CONTRARY TO THE REQUIREMENTS OF THE A.H,J., INSTALL PER A.H.J. ACOUSTIC DUCT LINER UNLESS OTHERWISE INDICATED ON THE PLANS, F&I 1" GLASS FIBER ACOUSTICAL DUCT LINER ON SUPPLY AND RETURN DUCTWORK WITHIN 10 FEET OF THE DISCHARGE AND INTAKE OF AIR HANDLING UNITS. INCREASE DUCT SIZED INDICATED N PLANS 2" IN EACH DIMENSION TO ACCOMMODATE LINER, UNER SHALL BE REVIEWED FOR CODE COMPLIANCE APPROVED AUG 2 5 2011 Al- fvt" City of da BUILDING VISION Permit ��" •. M Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the, violation of any adopted code or ordinance. Receipt of approved F ' '► %''� ' ' . L: .. is acknowledged: i By m, til 1 1 1 1 (40 g1-1E,17 s'-7o, v °* , p P� 4 RECEIVED f� v_ xQ AUG 16 2011 I ; i i , 1 ,, 39504 '`" PERMIT CENTER , i��s� NAL ' ANAL , .: r :• ! o ` Zci '" /1 city Of-Tukwila BUILDING DIVISION FASTENED TO DUCT WITH SMACNA. MECHANICAL LINER FASTENERS IN ACCORDANCE REVISIONS No changes shalt be made to the scope of work without Prior ao rovs_ of R Tukwila Building Division_ I NOTE: Revisions will require a new an su 14 and may include additional Ian r.J �_hm #,-.I R r f� WITH �.,. EXPIRES c, 0A09 Starbucks Coffee Company 2401 Utah Avenue South Seattle, Washington 98134 (206) 318 -1575 These Drawings and Specifications are confidential and shall remain the sole property of Starbucks Corporation. They shall not be reproduced (in whole or In part), shared with third parties or used in any manner on other projects or extensions to this project without the prior written consent of Starbucks Corporation. These drawings and specifications are intended to express Design Intent for a prototypical Starbucks store (which is subject to change at anytime) and do not reflect actual site conditions. Neither party shall have any obligation nor liability to the other (except as stated above) until a written agreement is fully executed by both parties. RENBCH &NGINR#RII1�t�f 4L6 111 AVE. C SUITE 104, SNOHOMi$H, 98290 PHe 3808834877 TIM 4249404099 ronsch.ongineeringecomeast.nat Revision Schedule. Rev Date By Description rrojecc Haaress: 3301 S. Norfolk St. Tukwila, WA 98168 Store #: Project #: Issue Date: Sbux Design Manager: Designed by: Drawn by: Checked by: TBD 5/2111 Anthony Perez Bill Bennecker Robert W. Rea Chris Rensch Sheet Title: Scale: Specifications Sheet Number: M -oat 30X30 ACCESS (COORD. W /GC) SIDE WALL VENT CAP STORAGE UNIT HVAC PLAN 3 4 12 8X8 EXHAUST TO UPPER LEVEL 20X10 UP (24X14 OD) 24X12 RETURN TO UPPER LEVEL 20X10 0(24X14 OD) GENERAL HVAC NOTES HVAC PLAN KEY NOTES 0 ALL IS NEW UNLESS NOTED OTHERWISE. 0 INSULATE DUCTWORK PER CODE AND SPEC REQUIREMENTS ON M -001 (ALL NOT SHOWN). COORD. CLEARANCE REQUIREMENTS FOR ADDED INSULATION. 0 SEE ARCH. SHEETS FOR PAINTING AND COLORS FOR ALL EXPOSED DUCT WORK, DIFFUSERS, GRILLES, ETC. 30X30 ACCESS (COORD WAG) GG) 24X12 RETURN TO UPPER LEVEL HVAC PLAN 22X22 PRESSURE RELIEF' TO UPPER LEVEL 0 0 0 0 0 0 COORDINATE WITH ELECTRICAL CONTRACTOR FOR POWER CONNECTION TO ALL MECHANICAL EQUIPMENT. INSULATE DUCT WITH 2" LINER. NOTE NOT USED. WALL MOUNTED THERMOSTAT FOR HVAC UNIT AT 60" AfF. THERMOSTAT SHALL BE 7 -DAY PROGRAMMABLE WITH NIGHT SETBACK AND A MINIMUM 5 DEGREE DEADBAND. CONFIRM HEIGHT COMPLIES WITH BARRIER FREE, AND ALL OTHER LOCAL REQUIREMENTS. REMOTE TEMPERATURE SENSOR AT CEILING. MANUAL BALANCE DAMPER (TYPICAL). MOUNT INLINE EXHAUST FAN TIGHT TO CEILING. FAN ?g RLrnl REVIEWED FOR 0 MULTIPLE THERMOSTATS SHALL BE STACKED IN A MAME COMPLIANCE CONFIGURATION WITH A MINIMUM 8" CLEARANCE BEL )W EAAPPROVED THERMOSTAT. CONTINUOUSLY. AUG 2 5 2011 City of Tukwila BUILDING DIVISION Nate: The General Contractor Shall Furnish, Permit & Install The Below Equipment. Equipment Schedule Design 1D Count Description Comments RTU -1 1 Package Horizontal Discharge Heat Pump (With Electric Backup Heat) Carrier 50EZ- A36 -5, 3.0 Ton Nom. Capacity, 1200 CFM @ 0.8 ESP MAX., 208 /30, MCA =36.5, MOCP =40, 3.8 KW HEATER, SEER =13.5, 7.7 HSPF, Unit Weight = 340 LBS, R410A, MicroMeti Economizer w /Filter Rack, RTU -2 1 Package Horizontal Discharge Heat Pump (No Electric Heat Needed) Carrier 50EZ- A36 -5, 3.0 Ton Nom. Capacity, 1200 CFM p@ 0.8 ESP MAX., 208/30, MCA =23.5, MOCP =30, SEER =13.5, 7.7 HSPF, Unit Weight = 340 LBS, R410A, MicroMetl Economizer w /Filter Rack, EF -1 1 Inline Exhaust Fan w /Damper Fan - Greenheck SO-80 -G With SCR Speed Controller (w /Backdrafter Preventer) 130 CFM @ 0.375" ESP Min. EF -2 1 !dine Exhaust Fan w /Damper Fan - Greenheck SQ -80 -D With SCR Speed Controller (wlBackdrafter Preventer) 210 CFM a@ 0.375" ESP Min. HVAC Schedule Design ID I Count I Description ( Responsibility I Comments CFM PER WC/ URINAL T -1 2 Thermostat w /Sensor GC Thermostat - Honeywell T7351 F Sensor - Honeywell T7770 X0100 1 Vertical Mt'd Supply Grille GC • Titus 300RL - 27x8, 29x10 Face X0101 1 Vertical Mt'd Supply Grille GC Titus 300RL - 8x8, 10x10 Face X0102 3 Vertical Mt'd Supply Grille GC Titus 300RL - 18x8, 20x10 Face X0103 1 Surface Mid Transfer Grille GC Titus 350RL - 8x8, 10x10 Face X0104 1 Surface Mt'd Relief Grille GC Titus 350RL - 22x22, 24x24 Face X0105 2 Lay -in Mt'd Return Grille GC Titus 350RL - 24x12, 26x14 Face X0106 _alr cLtrface Mt'd Exhaust Grille GC Titus 350RL - 8x8, 10x10 Face 1414 Ducting Systems 1414.1 Duct Sealing and Testing: Duct work and plenums shall be sealed in accordance wit. Section 1414.1.1. Additionally, ducts shall be tested in accordance with Sections 1414.1.2 . 1414.1.3 as required. 1414.1.1 Sealing: Duct work which is designed to operate at pressures above '/ inch water column static pressure shall be sealed as follows: 1. Static pressure '/ inch to 3 inches: Seal all transverse joints and longitudinal seams. Spiral lock seams in round and flat oval duct work do not require sealing; however, other seams shall be sealed. 2. Static pressure above 3 inches: Seal all transverse joints, longitudinal seams and duct wall penetrations. All low pressure supply and return air systems not located entirely within the conditioned space, including the unconditioned side of enclosed stud bays or joist cavities /spaces used to transport air, shall be securely fastened and sealed. Duct work shall be sealed using welds, gaskets, mas or mastic -plus- embedded -fabric tape. Enclosed stud bays or joist cavities /spaces used to transport air shall be sealed using mastic -plus- embedded -fabric tape, or when drywall is used to enclose the air system, drywall mud and tape. Duct tape is not permitted as a sealant on any ducts. EXCEPTION: Fibrous glass duct systems installed in accordance with Standard UL I8IA and flexible duct systems installed in accordance with Standard UL 181B may use tapes listed for these systems. 1414.1.2 Low Pressure Duct Leak Test: All duct systems shall be sealed to a leakage rate not to exceed 6 percent of the fan flow if the duct system: 1. Is connected to a constant volume, single zone, air conditioner, heat pump or furnace; and 2. Serves less than 5,000 square feet of floor area; and 3. Has more than 25 percent duct surface area located in any unconditioned space. The leakage rate shall be confirmed through field verification and diagnostic testing, in accordance with SMACNA Duct Leakage Test Procedures - 1985. 1414.1.3 High Pressure Duct Leak Test: Duct work that is designed to operate at static pressures in excess of 3 inches water column shall be leak- tested in accordance with SMACNA Duct Leakage Test Procedures - 1985. Representative sections totaling no less than 25 percent of the total installed duct area for the designated pressure class shall be tested. Duct systems with pressure ratings in excess of 3 in. w.e. shall be identified on the drawings. The maximum permitted duct leakage shall be: Lmax = CLP0.65 Where: Lmax = Maximum permitted leakage in cfm/100 112 duct surface area. CL = Duct leakage class, cfm /100 ft2 at 1 in. w.e. CL = 6 for rectangular sheet metal, rectangular fibrous, and round flexible ducts. CL = 3 for round/flat oval sheet metal or fibrous glass ducts. P = Test pressure, which shall be equal to the design duct pressur s rating in w.e. 11 1 IJ VENTILATION AIR CALCULATI (BASED 0 E 9 IMC 1MTH ATE DMEN ASHRAE STANDARD 62.1) AREA SERVED NUMBER OF WC 'S/ URINALS CFM PER WC/ URINAL TOTAL MN. EXHAUST CFM ANCY ZONE RESTROOMS OUTDOOR MR ZONE MR UNIT MN. 130 OCCUPANCY ZONE AREA DENSITY POPULATION OUTDOOR MR CFM CFM PER SF EFFECTIVNESS OUTDOOR AIR MARK AREA SERVED CATEGORY (Az) (P/1000 SF) (Pz) PER PERSON (Rp) (Ra) (Ez) (CFM) RTU -1 BAR KITCHEN 160 20 3 7.5 0.12 0.8 85 RTU -2 # RKROOM KITCHEN 195 20 3 7.5 0.12 0.8 95 NOTES: 1. HVAC UNITS SHALL BE BALANCED TO PROVIDE THE MINIMUM OUTDOOR AIR QUANTITIES INDICATED. RESTROON EXHAUST CALC. (BASED ON THE 2009 INC MATH STATE AMENDMENTS) MARK AREA SERVED NUMBER OF WC 'S/ URINALS CFM PER WC/ URINAL TOTAL MN. EXHAUST CFM PROPOSED EXHAUST CFM EF -1 RESTROOMS 1 50 50 130 RECEIVED AUG 16 2011 PERMIT CENTER I EXPIRES /c.7 20/7 Starbucks Coffee Company 2401 Utah Avenue South Seattle, Washington 98134 (206) 318 -1575 These Drawings and Specifications are confidential and shall remain the sole property of Starbucks Corporation. They shall not be reproduced (in whole or in part), shared with third parties or used in any manner on other projects or extensions to this project without the prior written consent of Starbucks Corporation. These drawings and specifications are intended to express Design Intent for a prototypical Starbucks store (which is subject to change at anytime) and do not reflect actual site conditions. Neither party shall have any obligation nor liability to the other (except as stated above) until a written agreement is fully executed by both parties. RIEN9CH I:NDINE #RINQ u.c 111 AVE. C SUITE 104, SNOHOMISH, 98290 PH: 380.883.6677 M: 425 - 949.8099 rensch.engl neertng©comcast.net Revision Schedule Rev Date By Description rrojeci Haaress: 3301 S. Norfolk St. Tukwila, WA 98168 Store #: Project #: Issue Date: Sbux Design Manager: Designed by: Drawn by: Checked by: TBD 5/2/11 Anthony Perez Bill Bennecker Robert W. Rea Chris Rensch Sheet Title: Scale: Mechanical HVAC Plan Sheet Number: M -111 20X10 DOWN (24X14 OD) BOTTOM OF CONTAINER IS OPEN ACCESS PANEL COORD. W /GC 20X10 DOWN (24X14 OD) I, 24X12 DOWN (28X16 OD). '-_�' OFFSET AS NEEDED REMOVABLE NETTING (COORD. W /GC) 24X12 DOWN (28X16 OD). OFFSET AS NEEDED SIDE WALL VENT CAP 8 "0 ACCESS PANEL (COORD. W /GC) BOTTOM OF CONTAINER IS OPEN GENERAL HVAC NOTES HVAC PLAN KEY NOTES �: J ALL IS NEW UNLESS NOTED OTHERWISE. B® INSULATE DUCTWORK PER CODE AND SPEC REQUIREMENTS ON M -001. COORDINATE CLEARANCE REQUIREMENTS FOR ADDED INSULATION. ® SEE ARCH. SHEETS FOR PAINTING AND COLORS FOR ALL EXPOSED DUCT WORK, DIFFUSERS, GRILLES, ETC. L 8X8 DN 22X22 PRESSURE RELIEF ECONOMIZER AIR INTAKE HOOD - 8"s END OF CONTAINER COVERED WITH EXPANDED STEEL TO ALLOW AIR TRANSFER & REMOVABLE TO ALLOW UNIT REPLACEMENT. (COORD. W /GC) M -112 TYP.) UPPER LEVEL HVAC PLAN REMOVABLE NETTING ( COORD. W /GC) UPPER LEVEL CONDENSER FAN ACCESS PANEL (CONFIRM REQUIRED SIZE) SLOPE BOTTOM FOR DRAINAGE HVAC UNIT DRIP PAN UNDER ENTIRE UNIT DRAINED TO INTERIOR DRAIN (COORD. W/PC). VIBRATION ISOLATORS (TYP.) 0 COORDINATE WITH ELECTRICAL CONTRACTOR FOR POWER CONNECTION TO ALL MECHANICAL EQUIPMENT. HVAC UNIT LOCATION SHALL BE FIELD VERIFIED & COORDINATED WITH CONTAINER VENDER & MANUFACTURES REQUIRED CLEARANCES. INSTALL NEW UNIT ON VIBRATION ISOLATOR SUPPORTS (SEE MECHANICAL SECTION). EXPOSED DUCT WIN 2" INSULATION LINER PER CODE. NOTE NOT USED. NOTE NOT USED. NOTE NOT USED. Q Q 0 0 ® SUSPEND INLINE EXHAUST FAN. INTERLOCK EXHAUST FAN CONTROL W /TIMECLOCK TO RUN FAN CONTINUOUSLY DURING OCCUPIED MODE (COORD W /EC). ® NOTE NOT USED. ® F&I LOW VOLTAGE WIRING, TRANSFORMER AND INTERTIE TO EF--1 TO OPEN WHEN FAN IS RUNNING. COORD W/EC FOR 120V POWER (NOT SHOWN). 10 F&I LOW VOLTAGE MOTORIZED DAMPER, LOW VOLTAGE WIRING, TRANSFORMER AND INTERTIE TO RTU -1 & RTU -2 TO OPEN IF ANY UNITS ECONOMIZER CONTROLS ARE ACTIVATED. COORD. W /EC FOR 120V POWER (NOT ALL SHOWN). REVIEWED FOR CODE COMPLIANCE APPROVED AUG 252011 City of Tukwila BUILDING DIVISION EXPANDED STEEL COVERING OPENING `I PAIN wi 2 FULL UNIT SIZE ROOF OPENING (N48 "X36 ") SEAL WATER TIGHT (COORD. W /GC) FULL UNIT SIZE DUCT TO ROOF (N47 "X36 ") FULL SIZE CONDENSER FAN OPENING DISCHARGE COLLAR CONNECTION (SEAL TO UNIT WATER TIGHT W /GASKET) MAIN LEVEL SIDE DISCHARGE SUPPLY AND RETURN. DUCT MOUNTED TIGHT TO CEILING NOTE: VERIFY DIMENSION OF ACTUAL BOX CONTAINER AS NEEDED. GRADE MECHANICAL SECTION '1. RECEIVED AUG 16 2011 PERMIT CENTER 1 EXPIRES % /30 /o. Starbucks Coffee Company 2401 Utah Avenue South Seattle, Washington 98134 (206) 318 -1575 These Drawings and Specifications are confidential and shall remain the sole property of Starbucks Corporation. They shall not be reproduced (in whole or in part), shared with third parties or used in any manner on other projects or extensions to this project without the prior written consent of Starbucks Corporation. These drawings and specifications are intended to express Design Intent for a prototypical Starbucks store (which is subject to change at anytime) and do not reflect actual site conditions. Neither party shall have any obligation nor liability to the other (except as stated above) until a written agreement is fully executed by both parties. RENESCH ENQINEERINQQ 111 AVE. C SUITE 104, SNOHOMISH, 98290 PH: 360.863.6677 It 425. 949.6099 rensch.englneeringacomcast.net Revision Schedule Rev Date By Description rrojeci Aaaress: 3301 S. Norfolk St. Tukwila, WA 98168 Store #: Project #: Issue Date: Sbux Design Manager: Designed by: Drawn by: Checked by: TBD 5/2/11 Anthony Perez Chris Rensch Yumi Roth Chris Rensch Sheet Title: Scale: Upper Level HVAC Plan Sheet Number: M -112