Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M11-120 - SHABELLE MINI MART
SHABEI.i.F MINIMART 14822 TUKWILA INTERNATIONAL BL Mi 1 -120 Parcel No.: Address: City oillrukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov MECHANICAL PERMIT 0041000143 14822 TUKWILA INTERNATIONAL BL TUKW Project Name: SHABELLE MINI MART Permit Number: M11 -120 Issue Date: 09/07/2011 Permit Expires On: 03/05/2012 Owner: Name: Address: Contact Person: Name: Address: Email: Contractor: Name: Address: Contractor License No: STEINBERG DOUG 26415 MILITARY RD S , KENT WA 98032 IBRAHIM BULHAN 2008 SHATTUCK AV S , RENTON WA 98055 IHBULHAN @GMAIL.COM Phone: 206 - 778 -7332 OWNER AFFIDAVIT - IBRAHIM BULHAN Phone: Expiration Date: DESCRIPTION OF WORK: REISSUANCE OF EXPIRED PERMIT M10-129 PUT IN A NEW HOOD AND DUCT (SMALL ONE) Value of Mechanical: $14,000.00 Type of Fire Protection: UNKNOWN Electrical Service Provided by: Permit Center Authorized Signature: Fees Collected: $355.06 International Mechanical Code Edition: 2009 U-B, R.2. Date: g_---7_ t I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this permit. Signature: Print Name: gt,s___ 1,,,t„,./i..-12,A1 (1 k 11 Date: 917/U This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -4/10 M11-120 Printed: 09 -07 -2011 • PERMIT CONDITIONS Permit No. M11-120 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Manufacturers installation instructions shall be available on the job site at the time of inspection. 7: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431- 3670). 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 10: ** *FIRE DEPARTMENT CONDITIONS * ** 11: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 12: A Type 1 hood shall be installed at or above all commercial cooking appliances and domestic cooking appliances used for commercial purposes that produce grease vapors. Each required commercial kitchen exhaust hood and duct system required by section 610 of the International Fire Code to have a Type 1 hood shall be protected with an approved automatic fire- extinguishing system installed in accordance with this code. (IFC 610.2,iIFC 994.2.1 and IFC 904.11) Automatic fire - extinguishing systems shall comply with UL 300 or other equivalent standards and Shall be installed in accordance with the requirements of the listing. (NFPA 96, 10.2.3) 13: Type I hood systems shall be designed and installed to automatically activate the exhaust fan whenever cooking operations occur. The activation of the exhaust fan shall occur through an interlock with the cooking appliances, by means of heat sensors or by means of other approved methods. (IMC 507.2.1.1) 14: All new automatic fire - extinguishing systems and all modifications to existing automatic fire - extinguishing systems shall have fire department review and approval of drawings prior to installation or modification. 15: Local U.L. central station supervision is required. (City Ordinance #2051) 16: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 17: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 18: Portable fire extinguishers shall be provided within a 30 -foot (9144 mm) travel distance of commercial -type cooking equipment. Cooking equipment involving vegetable or animal oils and fats shall be protected by a Class K rated portable extinguisher. (IFC 904.11.5) doc: IMC -4/10 M11 -120 Printed: 09 -07 -2011 19: Portable fire extinguishers, not used in cabinets, shall be installed on the h s or brackets supplied. Hangers or brackets shall be securely anchor the mounting surface in accordance with th ufacturer's installation instructions. Portable fire extinguish rs having a gross weight not exceeding 40 you s (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 20: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 21: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 22: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 23: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: IMC -4/10 M11 -120 Printed: 09 -07 -2011 CITY OF TUKW Community Develo t Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto:I/www.TukwilaWA.CIOV Mechanical limit No. r%( (( k Project No. (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *please print ** SITE LOCATION o King Co Assessor's Tax No.: Site Address: 14 O 2 Z i t. -`,. ttcl A ! n -in ' 1 1 Et id Suite Number: Floor: Tenant Name: l b rat k l� �t& V k`k e1 New Tenant: ❑ Yes -Fro Property Owners Name: (D b �G Sk-i n)9-e—r-� Mailing Address: City State Zip CONTACT PERSON — who do we contact when your permit is ready to be issued Name: I lOrCk. � l` �l 1 � R t e, ►- Mailing Address: Zoo ( ...C11 /1‘k6- (C E -Mail Address: (K (o (-& t �S r\ ( ". m CNA CO "'l y Telephone: Z o6 1 E 7 2.32- ` DA 1v314 o loss State Zip City Fax Number: MECHANICAL CONTRACTOR INFORMATION Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: State Zip ARCHITECT OF RECORD — All plans must be stamped by architect of record Company Name: Mailing Address: City Contact Person: Day Telephone: Fax Number: E -Mail Address: State Zip ENGINEER OF RECORD — All plans must be stamped by engineer of record Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: State Zip H:\Applications\Forms- Applications On Line\2010 Applications \7 -2010 - Mechanical Permit Application.doc Revised: May 2011 bh Page 1 of 2 111 1 �o 0 Valuation of project (contractor's bid price : $ ` Scope of work (please provide detailed information): iv\ rik • Use: Residential: New Commercial: New Replacement Replacement Fuel Type: Electric Gas ❑ El Other: Indicate type of mechanical work being installed and the quantity below: Unit Type: Qty Unit Type: Qty Unit Type: Qty Bioler /Compressor 0 -3 hp /100,000 btu Qty furnace <100k btu air handling unit >10,000 cfin fire damper furnace >100k btu evaporator cooler diffuser 3 -15 hp /500,000 btu floor furnace ventilation fan connected to single duct thermostat 15 -30 hp /1,000,000 btu suspended/wall/floor mounted heater ventilation system wood/gas stove 30 -50 hp /1,750,000 btu appliance vent hood and duct 1 1 emergency generator 50+ hp /1,750,000 btu repair or addition to heat/refrig/cooling system Incinerator — domestic other mechanical equipment air handling unit <10,000 cfm incinerator — comm/ind PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 AUTHORIZE =T: Signature: . Print Name: 1 �`u ` kc-- n Day Telephone: Mailing Address: CA° /J k. L IC / /Q S • -�'�� City Date: 8131 1 (1 ?J__ $ - -73? Z. 96'dss^ State Zip Date Application Accepted: Date Application Expires: 3 —�— Staff Initials: the H.1Applications\Forms- Applications On Line\2010 Applications17 -2010 - Mechanical Permit Application.doc Revised: May 2011 bh Page 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov RECEIPT Parcel No.: 0041000143 Permit Number: M11 -120 Address: 14822 TUKWILA INTERNATIONAL BL TUKW Status: PENDING Suite No: Applied Date: 08/31/2011 Applicant: SHABELLE MINIMART Issue Date: Receipt No.: R11 -01918 Payment Amount: $142.03 Initials: WER Payment Date: 08/31/2011 01:53 PM User ID: 1655 Balance: $0.00 Payee: SADIO FARAH TRANSACTION LIST: Type Method Descriptio Amount Payment Check 1042 142.03 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts MECHANICAL - NONRES 000.322.102.00.00 142.03 Total: $142.03 doc: Receiot -06 Printed: 08 -31 -2011 INSPECTION RECORD Rie• Retain a copy with permit Mk- 124 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION . 6300 Southcenter Blvd., #100, Tukwila. WA 98188 A (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 �h Project: Cs.i Ar l.1i AYt,4il Type of Inspection: i -; *,tA , Address: Date Called: Special Instructio ' : Date Wanted: 1 a.m. P.m. Requester: Phone No: EIApproved per applicable codes. Corrections required prior to approval. COMMENTS: I _ C4csot-N \ L c`" j-- . Yvl ctor: REINS •aid Date: ECTION FEE REQUI D. Prior to ext inspection, fee must be 6300 Southcenter Blvd . Suite 100. Call to schedule reinspection. • '. INSPECTION RECORD Retain a copy with permit . INSPECTION NO. PERMIT NO. CITY OFTUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 ' Permit. Inspection Request Line (206) 431 -2451 Project: - • • • . 'Sri i l—LC MIMI i11Af;7" Type of Ins ection: R611CoH--5—h j Date Called: Address: Special Instructions: • • Date Wanted:. / a.m Requester: Phone No: roved per applicable codes. E Corrections required prior to approval. COMMENTS: •, . • eqori: 1 SPECTION FEE REQbJIRED. Prior torfiext inspection. fee must be ai at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Date: % 7 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206 - 575 -4407 l.. r -1 Project: 5AA. 6 P�.1/ -e. CIA -C-q. Type of nspection: `bue.-�' � itAec. c- f0, k- - k r f Address: Suite #:' gc, -1- - _/, Contact Person: Occupancy Type: Special Instructions: Phone No.: 1 1) Approved per applicable codes. I I Corrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: 1�,k - —Ok 42-Qc4 it.n cw pre cil p .7a (-0,„,11-,'0..z. L L . A-s (b ( 14 s Z> r, re -CA f. r Po; )/4- 6t cet- -re-sir ! Ae ; A) K : t hoiki - sys , doos ,0,54- Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: < 5.-a -- Date: F/g3A Hrs.: /, $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: 1 Company Name: Address: City: State: Word /Inspection Record Form.Doc 6/11/10 Zip: T.F.D. Form F.P. 113 Fire Barrier Duct Wrap 615+ Duct Wrap Fire Protection System for Commercial Kitchen Grease and Ventilation Air Ducts Product Data BATS AND BLANKETS FOR USE IN FIRE RESISTIVE DUCT ASSawLTES SEE UL FIRE RESISIANCE DIRECTORY S0G9 USTED LISTED „ DUCT INSULATOR RR ESTOP SYSTEMS SEE IHTERTEKDLRECTORY 1. Product Description 3MT"" Fire Barrier Duct Wrap 615+ is a fire resistant wrap consisting of an inorganic fiber blanket encapsulated with a scrim - reinforced foil. The product is 1 -1/2 in. thick, 6pcf density.' It is used to fire rate commercial kitchen grease ducts as well as ventilation ducts, and is a proven alternative to 1 or 2 hour fire resistant rated shaft enclosures. With its excellent insulating capabilities, low weight and thin profile, it is and ideal choice for a duct enclosure system. This non - asbestos wrap installs easily because of its high flexibility and strength. Features • Two -layer wrap for grease ducts rated a§ a shaft alternative per ASTM E 2336 • Zero clearance to combustible throughot rthe entire enclosure system for congested spaces • One -layer wrap for fine- resistive ventilation ducts per ISO 6944 • High flexibility for installation ease • Foil encapsulated for blanket protection, Tess dust, and high wrap strength • Widest range of penetration seal systems .‘w . REVIEWED FOR' ∎CODE COMPLIANCE APPROVED RAT° SDP SEE TNTERTEK SAP 022011 City of Tukwila BUILDING DIVISION 2. Applications Two -layer applications of 3Mh' Fire Barrier Duct Wrap 615+ meet the criteria of ASTM E 2336 `Standard Test Methods for Fire Resistive Grease Duct Enclosure Systems'. 3MTM Fire Barrier Duct Wrap 615+ as single -layer fire resistant wrap application has passed the ISO 6944 `Fire Resistance Tests -Ventilation Ducts'. 3MTM Fire Barrier Duct Wrap 615+ is an ideal fire resistive enclosure for commercial kitchen grease ducts and ventilation air ducts. It is a proven performance aternative to a 1 or 2 hour fire resistant rated shaft enclosures and provides zero clearance to combustible construction throughout the entire enclosure system. 3MT"" Fire Barrier Water Tight Sealant 1000 NS, 3MT"" Fire Barrier Water Tight Sealant 1003 SL or 3MT"" Fire Barrier Water Tight Sealant 2000+ Silicone Sealants is used in combination with 3MTM Fire Barrier Duct Wrap 615+ to firestop the duct when the duct penetrates fire rated floors and walls. 3. Availability Unit Size Quantity Weight 45 Ibs (20.4 kg) 90 Ibs (40.8 kg) Roll Roll 24 in. x 25 ft. (60,9 mm x 635 cm) 48 in. x 25 ft. (121 cmx635cm) 1 1 4. Typical Physical Properties Blanket Color Weight White 0.9 Ibsift 2 (4.38 kg/m2) Milk 12 REGEVE AUG a 1.2011 PERMIT CENTER In accordance with the tolerances in ASTM C 892 Standard Specification for High - Temperature Fiber Blanket Thermal Insulation. 1 5. Performance A. 3M11" Fire Barrier Duct Wrap 615+ has been tested in accordance with the following: ASTM E 2336 Standard Test Methods for Fire Resistive Grease Duct Enclosure Systems ASTM E 119 Standard Test Methods for Fire Tests of Building Construction and Materials ASTM E 814 Standard Test Method for Fire Tests of Through - Penetration Fire Stops ASTM E 136 Standard Test Method for Behavior of Material in a Vertical Tube Fumace at 750°C (1382 °F) ASTM C 518 Standard Test Method for Steady -State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus ASTM C 1338 Standard Test Method for Determining Fungi Resistance of Insulation Materials and Facings ASTM E 84 Standard Test Method for Surface Buming Characteristics of Building Materials ISO 6944 -85 Fire Resistance Tests — Ventilation Ducts B. Surface Burning Characteristics (ASTM E 84, ULC /CAN S -102) Flame Spread Smoke Developed Foil Encapsulated Blanket <25 <50 F. Design Listings C. Thermal Conductivity Temp. Btu — in. W hr - ft1 - °F m2 -K 500°F (260 °C) 0.48 0.07 1000°F (537°C) 0.97 0.14 1500°F (815 °C) 1.57 0.23 1800°F (982 °C) 1.98 0.29 2000°F (1093 °C) 2.23 0.33 D. Linear Shrinkage 24 Hr @ 2012 °F (1000 °C): 1.2% E. R -Value Single layer of 3MTM Fire Barrier Duct Wrap 615+ at 77 °F (25 °C): 6.38 °F - ft2 - hr Btu Fire Resistive Rating Enclosure System Third -Party Testing Services I Design Listing I Description Grease Duct Listings - ASTM E 2336 1 and 2 Hour 2 layers of 3MT"' Fire Barrier Duct Wrap 615 +, minimum 3 in. (76 mm) perimeter and longitudinal overlaps (ntertek 3MU /FRD 120 -18 48 x 48 in. Rectangular 48 in. Round (ntertek 3MU /FRD 120 -19 Venti_ Ia_ tion Duct Listings - ISO 6944 1 and 2 Hour 1 layer of 3MT"" Fire Barrier Duct Wrap 615 +, minimum 3 in. (76 mm) perimeter and longitudinal overlaps (ntertek 3MU /FRD 120 -15 Underwriters Laboratories HNLJ.V -27 24 x 85 in. Rectangular (ntertek 3MU/FRD 120-04 40 in. Round G. Codes and Standards 3MT'" Fire Barrier Duct Wrap 615+ installed per ASTM E 2336 tested Design Listings meets the requirements of the following codes: NFPA 96, 2008 Edition 2006/2009 International Mechanical Code 3MT'" Fire Barrier Duct Wrap 615+ installed per ISO 6944 tested Design Listings can be utilized to meet the requirements of the following codes: NFPA 92A Standard for Smoke - Control System Utilizing Barriers and Pressure Differences, 2006 Edition - Section 6.6.2 NFPA 92B Standard for Smoke Management Systems in Malls, Atria, and Large Spaces, 2005 Edition - Section 7.5.2 NFPA 101® Life Safety Code ®, 2006 Edition - Section(s) 8.6.7, 18.7.7 International Mechanical Code ®, 2006 Edition - Section 513.10.2 International Building Code ®, 2006 Edition - Section 909.10.2 These are only partial lists for design listings and code requirements. For the latest code and approval information go to www.3M.com /firestop or speak to your authorized 3M distributor or sales representative at (800) 328 -1687. 2 6. Installation Techniques 3MTM Fire Barrier Duct Wrap 615+ should be installed per the application design listing in accordance with the following basic installation instructions. A. Material and Equipment • 3MTM Fire Barrier Duct Wrap 615+ blanket, 1 -1/2 in. (38 mm) thick2, 24 in. (60 cm) or 48 in. (121 cm) wide, 25 ft. (635 cm) standard length. The 48 in. (121 cm) wide blanket helps to minimize waste. • Aluminum foil tape. • Minimum 3/4 in. (19 mm) wide filament tape. • Stainless steel banding material, minimum 1/2 in. (12,7 mm) wide, minimum 0.015 in. (0,38 mm) thick, with stainless steel banding clips. • Hand banding tensioner, crimping tool and banding cutter. • Minimum 12 gauge copper - coated steel insulation pins used with minimum 2 -1/2 in. (38 mm) square galvanized steel or stainless speed clips or 1 -1/2 in. (38 mm) dia. round or equivalent sized insulated cup -head pins. • Capacitor discharge stud gun. • Access door hardware: four galvanized steel thread rods, 1/4 in. (6 mm) diameter by minimum 6 in. long (152 mm) with 1/4 in. (6 mm) wing nuts and 1/4 in. (6 mm) washers. • 4 in. (102 mm) long steel hollow tubing to fit threaded rods. • Minimum 4 pcf (64 kg/m3) density mineral wool or scrap pieces of 3MTM Fire Barrier Duct Wrap 615 +. • 3MTM Fire Barrier Water Tight Sealant 1000 NS, 1003 SL or 3MTM Fire Barrier Silicone Sealant 2000 +. B. Storage The 3MTm Fire Barrier Duct Wrap 615+ and 3MT"" Fire Barrier Water Tight Sealant 1000 NS, 1003 SL or 3MTM Fire Barrier Silicone Sealant 2000+ must be stored in a dry warehouse environment. Pallets should not be stacked. C. Preparatory Work 3MTM Fire Barrier Duct Wrap 615+ is installed with common tools, such as knives, banders and capacitor discharge guns for applying insulation pins. In order to install the duct firestop system, the surfaces of all the openings and penetrating items need to be clean, dry, frost free and free of dust. D. Method (Two -Layer for ASTM E 2336) Note: These general instructions for installing 3MTM Fire Barrier Duct Wrap 615+ include a two -layer wrap construction of 24 -inch 3MTM Fire Barrier Duct Wrap 615+ blanket applied directly to a grease duct. To minimize waste, 3MTM Fire Barrier Duct Wrap 615+ material should be rolled out tautly before measuring. The first layer of 3MTM Fire Barrier Duct Wrap 615+ blanket is wrapped around the perimeter of the duct and is cut to a length to overlap itself not less than 3 in. (76 mm). The overlap made by adjacent blankets forms the "longitudinal" overlap. Aluminum foil tape is used to seal all cut edges of the blanket and any tears in the foil scrim. This first layer is temporarily held in place using filament tape. The first layer does not require stainless steel banding. The second layer of 3MT"" Fire Barrier Duct Wrap 615+ blanket is wrapped around the perimeter of the previously installed first layer of 615 +, and is cut to at length to overlap itself not less that 3 in. (76 mm). The centerline of the second layer of blanket should be centered over the overlap of the first layer. The second layer of blanket requires longitudinal overlap onto adjacent blankets of not less than 3 in. (76 mm). The second layer of blanket is also held in place using filament tape. The second layer of wrap requires permanent fastening with stainless steel banding or rows of weld pins (impaling or cup -head style). 2 In accordance with the tolerances in ASTM C 892 Standard Specification for High- Temperature Fiber Blanket Thermal Insulation. 3 Figure 1 3MTM' Fire Barrier Duct Wrap 615+ Commercial Kitchen Grease Duct Systems 1 or 2 Hour Shaft Alternative Zero Clearance to Combustibles Telescoping Wrap Technique With Banding For Ducts 24 inches (60,9 cm) or Less 1. First Layer 3MTM Fire Barrier Duct Wrap 615+ 2. Second Layer 3MTM Fire Barrier Duct Wrap 615+ 3.3/4 in. (19 mm) Wide Filament Tape 4. Steel Banding 1/2 in. (13 mm) Wide Min. Typical for Permanent Fastening 5.3 in. (76 mm) Min. Longitudinal Overlap 6.3 in. (76 mm) Min. Perimeter Overlap System integrity is limited by quality of installation. Ducts > 24 in. (60,9 cm) Wide Require Pinning on the Bottom Side. Consult Current Independent Testing Laboratories (Intertek, UL) For Design or System Details. There are three (3) approved installation techniques for installing the 3MTM' Fire Barrier Duct Wrap 615+ (See Figures 1A, 1B, & 1C): 1.Telescoping 3 in. (76 mm) Overlap Wrap Cross Section View With the telescoping overlap wrap method, each blanket overlaps one adjacent blanket, and each blanket has one edge exposed and one edge covered by the next blanket as shown in Figure 1A. The visible edges of the perimeter overlaps all point in the same direction. 1. One Layer 3MTM Fire Barrier Duct Wrap 615+ 2. Steel Banding 1/2 in. (13 mm) Wide Min. Typical 3.3 in. (76 mm) Min. Longitudinal Overlap 2. Checkerboard 3 in. (76 mm) Overlap Wrap Cross Section View With the 3 in. (76 mm) checkerboard overlap wrap method, blankets with both edges exposed alternate with blankets with covered edges, as shown in Figure 1B. The visible edges of the perimeter overlaps alternate their directions and appear on every other blanket. 1. One Layer 3MTM Fire Barrier Duct Wrap 615+ 2. Steel Banding 1/2 in. (13 mm) Wide Min. Typical 3.3 in. (76 mm) Min. Longitudinal Overlap 4 Figure 1A Figure 1B 3. Butt Joint With Collar Cross Section View With the butt joint and collar method, adjacent blankets are butted tightly together and 6 in. (152 mm) wide collar of duct wrap is centered over the joint, overlapping each blanket by 3 in. (76 mm) minimum as shown in Figure 1. 1. One Layer 3MTM Fire Barrier Duct Wrap 615+ 2. Steel Banding 1/2 in. (13 mm) Wide Min. Typical 5. 6 in. (152 mm) Min. Wide 615+ or 20A Collar 6. Firmly Butted Joint Figure 1C System integrity is limited by quality of installation. Consult Current Independent Testing Laboratories (Intertek, UL) For Design or System Details. In all three overlap techniques the perimeter overlap can occur at any location on the duct. The blanket is mechanically attached to the duct by steel banding or by welded insulation pins and clips for all three installation methods listed above. For Banding Only (See Figure 1) Filament tape can be used to temporarily hold the blanket in place until the banding is applied. The steel banding is applied around the duct 1 -1/2 in. (38 mm) from each edge of the blanket, and maximum 10 -1/2 in. (26,7 cm) centers. The banding is placed around the material and tightened so as to sufficiently hold the 3M-r"' Fire Barrier Duct Wrap 615+ in place against the duct, compressing the foil but not cutting the foil. Additional Pinning to Prevent Sagging of the Wrap For Ducts 24 in. (60 cm) and larger in width, additional pins are needed to support the blanket on the bottom horizontal surface and on the outside face of a vertical duct run. Space pins a maximum of 10-1/2 in. (26,7 cm) apart in the direction of the blanket width, and a maximum of 12 in. (30 cm) apart in the direction of the blanket length. Refer to paragraph below for more information on Mechanical Fastening with Pins. For Mechanical Fastening with Pins Only Insulation pins are welded to the duct in the centers of the overlaps a minimum of 1 -1/2 in. (38 mm) from each edge of the blanket, and spaced a maximum of 10 -1/2 in. (26,7 cm) on center along perimeter overlap, and a maximum of 10-1/2 in. (26,7 mm) on center along longitudinal overlaps. The blanket is impaled over the pins and held in place by galvanized speed clips. Insulation pins that extend beyond the blanket wrap shall be turned down to eliminate sharp points. Insulated cup -head pins can be used at the same spacing requirements of the insulation pins. NOTE: Support hangar systems do not need to be wrapped provided the hangar rods are at least a minimum of 3/8 in. (9,53 mm) diameter and spaced a maximum of 60 in. (152 cm) on center along the length of the duct. Use a minimum 2 in. x 2 in. x 1/4 in. (50 mm x 50 mm x 6,35 mm) steel angle steel support channel or SMACNA equivalent support system. 5 Figure 2 3W"° Fire Barrier Duct Wrap 615+ Commercial Kitchen Grease Duct Systems 1 or 2 Hour Access Door System 1. Access Hole 2. 1/4 in. (6 mm) Dia. All Threaded Rods 3. Access Cover -16 Gauge 4. Insulation Pins - Welded 5. First Layer 3MT"" Fire Barrier Duct Wrap 615+ Cut Same Size As Cover 6. Second Layer 3MT"" Fire Barrier Duct Wrap 615+ with 1 in. (25 mm) Overlap On All Sides 7. Third Layer 3MT"" Fire Barrier Duct Wrap 615+ with 1 in. (25 mm) Overlap On All Sides 8. Speed Clips 9. Aluminum Tape Covering All Exposed Edges 10. Spool Pieces For Threaded Rods 11. 1/4 in. (6 mm) Diameter Wings Nuts System integrity is limited by quality of installation. Consult Current Independent Testing Laboratories (Intertek, UL) For Design or System Details. Access Door Installation Four galvanized steel threaded rods, 1/4 in. diameter (6,35 mm) by 4 -1/2 in. to 5 in. long (114 mm to 127 mm) are welded to the duct at the comers of the door opening. Four steel tubes, each 3 in. (76 mm) long, are placed over the rods to act as protection for the 3MTM Fire Barrier Duct Wrap 615+ when fastening the door. Four insulation pins are welded to the door panel for installation of the blanket. One layer of 3MTM Fire Barrier Duct Wrap 615+ is cut approximately the same size as the access panel and impaled over the insulation pins on the panel. It is essential that this layer fit tightly against the wrap surrounding the access door opening with no through openings. A second layer of 3MTM Fire Barrier Duct Wrap 615+ is cut so as to overlap the first layer by a minimum of 1 in. (25,4 mm). A third layer of 3MT"' Fire Barrier Duct Wrap 615+ is cut so as to overlap the second layer by a minimum of 1 in. (25,4 mm). The third layer is impaled over the pins and all three layers are locked in place with galvanized or stainless steel speed clips. Pins that extend beyond the outer layer of 3MTM Fire Barrier Duct Wrap 615+ shall be turned down to avoid sharp points on the door. The insulated door panel is placed over the threaded rods and held in place with washers and wing nuts. The details are shown in Figure 2. 6 Figure 3 3MT"" Fire Barrier Duct Wrap 615+ Commercial Kitchen Grease Duct Systems 1 or 2 Hour Through Penetration Systems 4-1/2 inch (11,4 cm) Concrete Floor or Wall 1. Floor /Ceiling or Wall Assembly 2. Duct 3. One or Two Layers 3MTM Fire Barrier Duct Wrap 615+ 4. Banding or Pinning 5. Packing Material 6. 3MT"" Fire Barrier Water Tight Sealant 1000 NS, 3MT"" Fire Barrier Water Tight Sealant 1003 SL, or 3MT"' Fire Barrier Silicon Sealant 2000 +. For Wall Assembly Apply Sealant To Both Sides of Wall. 3MTM Fire Barrier Water Tight Sealant 1003 SL Not Suited For Wall Applications. System integrity is limited by quality of installation. Consult Current Independent Testing Laboratories (Intertek, UL) For Design or System Details. Penetrations When the duct penetrates a fire rated wall, ceiling or floor, an approved firestop system must be employed. Figure 3 illustrates a typical condition. To firestop the wrapped duct, follow the installation parameters detailed in a compatible ASTM E 814 tested through - penetration firestop design. Note: Through - penetration designs in which the duct is bare where it passes through combustible or limited - combustible construction (e.g. gypsum walls or wood joist floor - ceiling assemblies) are appropriate for ventilation duct scenarios only. It is not appropriate for bare, uninsulated grease ducts to pass through combustible assemblies. Through Penetration Systems ASTM E 814 Intertek Testing Services Sealants Fire Resistive Rating Design Listing (former OPL name) Description Firestopped To 3MTM Fire Barrier Water Tight Sealant 1000 NS 3MT"" Fire Barrier Water Tight Sealant 1003 SL 3MT^" Fire Barrier Silicone Sealant 2000+ 1 Hour 3MU/PH 60-01 FS 557 W Gypsum Wall Duct Wrap 3MU /PV 60-01 FS 558 F Floor - Ceiling Duct Wrap 2 Hour 3MU/PH 120 -14 FS 559 W Gypsum Wall Duct Wrap 3MU/PH 120 -16 FS 563 W Concrete Wall Bare Duct 3MU /PH 120 -17 FS 566 W Gypsum Shaft Wall Bare Duct 3MU/PH 120 -18 FS 568 W Gypsum Wall Bare Duct 3MU/PH 120 -29 FS 579 W Concrete Wall Duct Wrap 3MU/PV 120-06 FS 576 F Concrete Floor Bare Duct 3MU /PV 120 -07 FS 578 F Concrete Floor Duct Wrap For technical data and properties of 3MT"' Fire Barrier Water Tight Sealant 1000 NS, 3MT"" Fire Barrier Water Tight Sealant 1003 SL or 3MT'" Fire Barrier Silicone Sealant 2000 +, see separate product data sheets available from your 3M representative or go to www.3M.com /firestop. This is only a partial list of design listings. For the latest information go to www.3M.com /firestop or speak to your authorized 3M distributor or sales representative at (800) 328 -1687. 7 7. Maintenance No maintenance is required when installed in accordance with the 3M Installation Instructions. Once installed, if any section of the 3MTM Fire Barrier Duct Wrap 615+ is damaged so that the blanket requires repair, the following procedures apply: • The damaged section should be removed by cutting the steel banding or removing the clips holding it in place. • A new section of the same dimension should be cut from a roll of 3MTM Fire Barrier Duct Wrap 615 +, either 24 in. (60,9 cm) or 48 in. (121 cm) wide. • The new section should be placed and fitted ensuring the same overlap that existed previously. • The steel banding should be placed around the material and tensioned so as to sufficiently hold the 3MTM Fire Barrier Duct Wrap 615+ in place. • If the blanket has not been damaged but the foil has ripped, seal the rips with aluminum foil tape. 8. Purchase Information 3M Fire Barrier products are available through a network of nationwide distributors. For information on where to buy, go to www.3M.com /firestop. 9. Safe Handling Information Consult Material Safety Data Sheet prior to handling and disposing of 3MTm Fire Barrier Duct Wrap 615 +. Important Notice to User: Product Use: Many factors beyond 3M's control and uniquely within user's knowledge and control can affect the use and performance of a 3M product in a particular application. Given the variety of factors that can affect the use and performance of a 3M product, user is solely responsible for evaluating the 3M product and determining whether it is fit for a particular purpose and suitable for user's method of application. Warranty and Limited Remedy: 3M warrants that each 3M Fire Protection Product will be free from defects in material and manufacture for 90 days from the date of purchase from 3M's authorized distributor. 3M MAKES NO OTHER EXPRESS OR IMPUED WARRANTIES, INCLUDING ANY IMPUED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. If a 3M product does not conform to this warranty, the sole and exclusive remedy is, at 3M's option, replacement of the 3M product or refund of the purchase price. Limitation of Liability: Except where prohibited by law, 3M will not be liable for any loss or damage arising from the 3M product, whether direct, indirect, special, incidental or consequential, regardless of the legal theory asserted. Building and Commercial Services Division St. Paul, MN 55144 -1000 1 -800- 328 -1687 3M.com /firestop Please recycle. Printed in U.S.A. C 3M 2009. All rights reserved. 98- 0213 - 4605 -5 08/2009 rev° 3M is a trademark of 3M. I\•) Not or use with any kitchen exhaust applications. ( ") Drive package consists of appropriate motor. belts, and sheaves to obtain performance listed. POWE 110 74 F VEHTILATO s Belt -Drive Upblast Exhaust A For more information on selecting commercial kitchen exhaust & suppl9r 8eatilators, see page 4128. r-• - 3950 GRAINGER. Mt Ml CONTI::Cdb Men EIV D 31 ea neap Centrifugal Belt-Drive Upblast Exhaust Ventilators Dayton` • Aluminum, backward inclined, nonoverloading to create a virtually centrifugal wheel design leakproof seal between the ventilator sue°* �r - • NEMA 1 junction box located in motor enclosure and the mounting surface. Internal £ � • Max. inlet air temp.: 300 °F steel support braces and a fully rolled • UL 705 Listed for Power Ventilators windband dramatically increase the rigidity of `=- �*� -' ■ Air handling quality bearings meet min. 110- the ventilator for greater stability during trans- xt 100,000 hrs. port and installation. ..=:/ r • Bearings -units without drive package: sealed Motor, drive frame, and blower wheel are � * ski -5s" pillow block up to 161/2" wheel dia., regreasable isolated from the mounting base by independent pillow block for 181" wheel dia. and larger neoprene studs -no metal -to -metal contact, -° • Bearings - assembled units: sealed pillow block mat reducing overall noise. Motor cam art- ,t greatly 9 air up to 181h" wheel dia., regreasable pillow block ment is isolated from the contaminated air - �..•. for 211/4' wheel dia. and larger stream and is cooled by outside air that is pulled • UL 762 Listed Restaurant Exhaust Equipment in through an oversized breather tube by the s:. • NFPA 96 requires the use of a ventilated roof spinning action of the wheel. Motors, sheaves, ° curb, grease trap, clean -out port, and hinge kit and belts are packed separately when unassem- No. 42"2"78 in restaurant applications; for NFPA 96 bled ventilator with drive package is ordered. UL accessories, see page 3948 and C -UL Listed. Designed for use in restaurants, schools, and tom -.• • 1 '. - r! • • "Grainger Industrial Supply Page 1 of 2 GRAINGER. printed September 23, 2010 Additional Info Exhaust Vent, 14 3/4 In Exhaust Ventilator, Centrifugal Upblast, Less Drive Package, CFM Range 2001 to 3125 @ 0.0 In SP, Roof Mounting Location, Base Width 26 In, Base Length 26 In, Overall Height 28 1/4 In, Max. Inlet Temp. 300 Deg. F, HP Range 1/4 to 1, 590 to 1725 RPM Range, Wheel Dia 14 3/4 In, Wheel Material Aluminum, Housing Material Spun Aluminum. General /Kitchen Application, Includes NEMA 1 Junction Box Grainger Item # 4YY16 Price (ea.) $948.50 Brand DAYTON Mfr. Model # 4YY16 Ship Qty. 1 Sell Qty. (Will -Call) 1 Ship Weight (Ibs.) 58.0 Usually Ships Today Catalog Page No. 3950 Price shown may not railed your price. Log In or register. Centrifugal Belt -Drive Upblast Exhaust Ventilators Designed for use in restaurants, schools, and commercial and industrial applications to exhaust contaminated air from kitchen range hoods up and away from the roof. 1-pc. rolled aluminum windband is fully welded to the base to create a virtually leakproof seal between the ventilator and the mounting surface. Internal steel support braces and a fully rolled windband dramatically increase the rigidity of the ventilator for greater stability during transport and installation. Motor, drive frame, and blower wheel are isolated from the mounting base by independent neoprene studs -no metal- to-metal contact, greatly reducing overall noise. Motor compartment is isolated from the contaminated air stream and is cooled by outside air that is pulled in through an oversized breather tube by the spinning action of the wheel. Motors, sheaves, and belts are packed separately when unassembled ventilator with drive package is ordered. UL and C-UL Listed. • Aluminum, backward inclined, nonovertoading centrifugal wheel design • NEMA 1 junction box located in motor enclosure • Max. inlet air temp.. 300 DegreeF • UL 705 Listed for Power Ventilators • Air handling quality bearings meet mm. L10- 100,000 hrs a Bearings -units without drive package: sealed pillow block up to 161/7' wheel dia., regreasable pillow block for 18 1/2" wheel dia. and larger • Bearings - assembled units: sealed pillow block up to 18 1/2" wheel dia., regreasable pillow block for 21 1/4" wheel dia. and larger a UL 762 Listed Restaurant Exhaust Equipment • NFPA 96 requires the use of a ventilated roof curb, grease trap. clean-out port. and hinge kit in restaurant applications: for NFPA 96 accessories, see page 3948 Tech Specs Optional Accessories Wheel Dia. (In.): 14 -3/4 Wheel Type: Backward Incline CFM Range: 2001 to 3125 @ 0.0" SP Max. Inlet Temp. (Deg. F): 300 Bearing Type: Sealed Motor HP Range: 1/4 to 1 RPM Range: 590 to 1725 Speed Controllable: No Mounting Location: Roof Base Width (In.): 26 Base Length (In.): 26 Base Height (In.): 1 3/4 Overall Height (In.): 28 1/4 Overall Dia. (In.): 28-3/8 Shaft Dia. Wheel End (In.): 3/4 Shaft Dia. Sheave End (In.): 3/4 Damper, Roof Mount Item #: 4HX66 Brand: DAYTON Usually Ships: Today Price (ea): $39.50 Birdscreen, 121/4 In der • Item #: 4YY79 Brand: DAYTON Usually Ships: Today Price (ea): $28.10 Roof Curb, Fixed, 12 in H, 241/2 In OD Item #: 2RB77 http: / /www.grainger.com /Grainger /wwg/itemDetails.shtml 9/23/2010 • .. -Grainger Industrial Supply Page 2 of 2 Housing Material: Spun Aluminum Wheel Material: Aluminum Agency Compliance: UL/cUL 705/762 Requires: Roof Curb For New Installation Includes: NEMA 1 Junction Box Adj. 12 3!8 "H Roof Curb Stock No.: 2ZV83 Recommended 12 In, Fixed Curb Item No.: 2RB77 Recommended 8 In. Fixed Curb Item No.: 4HX40 Fixed UL 762 Kitchen Roof Curb Stock No.: 4HX56 Adj. UL 762 Kitchen Roof Curb Stock No.: 4HX62 Recommended Damper Size (In.): 19 x 19 Recommended Damper Stock No.: 4HX66 Notes & Restrictions Brand: DAYTON Usually Ships: Today Price (ea): $132.90 Roof Curb, Adustable Width Item #: 2ZV83 Brand: DAYTON Usually Ships: 1 -3 Days Price (ea): $378.00 Clean Out Port Kit Item #: 3ATV9 Brand: DAYTON Usually Ships: 1 -3 Days Price (ea): $194.50 WARNING: Do not use a damper in any kitchen Alternate Products installation. MSDS This item does not require a Material Safety Data Sheet (MSDS). Required Accessories Roof Curb, 8 in High Item #: 4HX40 Brand: DAYTON Usually Ships: Today Price (ea): 6193 75 Roof Curb, 12 to High Item #: 4HX48 Brand: DAYTON Usually Ships: Today Price (ea): 5244.75 Roof Curb, 24 In High Bern #: 4HX56 Brand: DAYTON Usually Ships: Today Price (ea): 5299.00 Roof Curb, 24 In High Bern #: 4HX62 Brand: DAYTON Usually Ships: 1 -3 Days Price (ea): $630.50 Hinge Kit Item #: 4HX79 Brand: DAYTON Usually Ships: Today Price (ea): 597.35 There are currently no alternate products for this item. Repair Parts Repair Parts Information is available for this item. http: / /www.grainger.com /Grainger /wwg/itemDetails.shtml 9/23/2010 k L Commercial & Industrial COD sui ■ Double Inlet Full- a and 3 3/4 -Width Forward Curve B -- a . . 0 . a;+� Lea 9'h 7'6 !16" Aa 9'As 14 "As W Ws 9-1As 1 1293 1130 742 6 690 1/4 170536 404.75 7 70598 487.50 41196 ✓ 157.00 9'h 7'6 F14?4e 933e 12'h 6 631a WA. 1 1098 1022 7 706 1/6 170542 444.25 - - - 47197 1 198.75 E S c • 9 63Se 1194a 8 1645 1426 968 7 700 1/4 1 70548 403.25 7 70609 470.50 47198 s 163.00 ' 1 1587 1280 5 565 1/4 1 70554 449.00 7 70615 532.00 7r E® ) (8) WARNING: Motor overload will result if blower is operated at static pressure below performance shown. ( ") Drive package consists of appropriate moto . belt. and sheaves to obt.. �.. Ncr w..._ listed. 3972 GRAINGER. AUG ..3 i ion tit 10 PEINIMMYER 'Grainger Industrial Supply Page 1 of 2 GRAINGER. printed September 23, 2010 Additional Info Blower, 12 5/8 In Blower. Unassembled, Double Inlet Forward Curve, Belt Drive, With Drive Package, Wheel Dia 12 5/8 In, CFM Range 3001 to 2421 @ 0.125 -In SP to 0.375 -In SP, Voltage 208 - 230/460, 60 Hz, 3 Phase, Single Speed, Motor HP 1/2, Blower RPM 535, Housing Height 21 11/16 In, Housing Width 15 5/8 In, Housing Depth 19 3/8 In, Discharge Height 8 3/8 In, Discharge Width 15 5/8 In, Multi- postion Mounting, Includes Motor Mounting Bracket, Isolation Grommets and Mounting Hardware Grainger Item # 7D638 Price (ea.) $569.50 Brand DAYTON Mfr. Model # 7D638 Ship Qty. 1 Sell Qty. (Will -Call) 1 Ship Weight (lbs.) 64.4 Usually Ships Today Catalog Page No. 3972 Price shown may not reflect your once. Log in or register. Double Inlet Full- and 3/4 -Width Forward Curve Belt -Drive Blowers Prelubricated, sealed ball bearings with rubber isolators and dynamically balanced forward curved wheel. Precision ground shafting with both keyways and flats for a wide range of drives and HP. A variable pitch motor sheave is provided when ordered complete with drive package for speed adjustment. Die - stamped steel housing with mounting supports. Mounting hardware and isolation grommets included. Blowers include a motor mounting bracket built for 1 1/2 HP maximum. 1/6- to 1 1 /2 -HP motor and drives for bottom horizontal discharge packed separately when ordered complete. Longer or shorter belt may be required for other discharge positions. 2- to 5-HP motors are floor mount only. a Max. blower operating temp : 150 DegreeF is Max. motor operating temp: 104 DegreeF s Discharge can be rotated in four 90 Degree increments Tech Specs Optional Accessories Item: Blower Type: Unassembled, Double Inlet Forward Curve, Belt Drive. With Drive Package Wheel Dia. (In.): 12 -5/8 Wheel Width (In.): 12-5/8 CFM Range: 3001 to 2421 © 0.125 -In SP to 0.375 -In SP CFM t 0.125 -In. SP: 3001 CFM @ 0.250 4n. SP: 2818 CFM 0.375 -In. SP: 2421 Max. Inlet Temp. (Deg. F): 150 Max. Ambient Temp. (F): 104 Voltage: 208- 230/460 Hz: 60 Phase: 3 Full Load Amps: 2.0- 2.0/1.0 Speed: 1 Motor RPM: 1725 Motor HP: 1/2 Bearing Type: Ball Motor Type: Three Phase Motor Enclosure: Open Dnpproof Blower RPM: 535 Housing Height (In.): 21 -11/16 Housing Width (In.): 155/8 Housing Depth (In.): 19 -3/8 There are currently no optional accessories for this item. Alternate Products Blower, 12 5/8 In Item #: 70575 Brand: DAYTON Usually Ships: Today Price (ea): $540.50 Blower, 12 518 In Item #: 70637 Brand: DAYTON Usually Ships: Today Price (ea): 5569.50 Repair Parts A Repair Part may be available for this item. Visit our Repair Parts Center or contact your local branch for more information. htto://www.arainur.com/Grainur/wweitemDetails.shtml 9/23/2010 Grainger Industrial Supply Page 2 of 2 Discharge Height (In.): 83/8 Discharge Width (In.): 15-5/8 Mounting: Multipostion Housing Material: Steel Housing Finish: Gray Speed Controllable: No Includes: Motor Mounting Bracket, Isolation Grommets and Mounting Hardware Footnotes: # Motor Overload Condition Notes & Restrictions There are currently no notes or restrictions for this item. MSDS This item does not require a Material Safety Data Sheet (MSDS). Required Accessories There are currently no required accessories for this item. http: / /www.grainger.com /Grainger /wwg/itemDetails.shtml 9/23/2010 ics FILE COPY Product Data and Installation ZermIlt `� '--"----� �---- 1. Product Description r"- As the pioneer of fire resistive, flexible duct enclosure pro- tection, Thermal Ceramics coRl a jgliiable ?Rd safe fire protection solutions. To complement the FireMaster FastWrap® XL grease duct wrap enclosure system, Thermal Ceramics now offers fully fire tested and building code com- pliant FireMaster pre - fabricated duct access doors. These FireMaster Access Doors combine the proven reliability of DuctMate® F2 -HT high temperature doors and the fire test- ed performance of FireMaster FastWrap XL flexible enclo- sure wrap. These pre - insulated and ready to install doors offer time and money savings versus the typical field fabricated access door, and provide more reliability for grease and fire contain- ment. Product Features • Access doors are insulated with FireMaster which is thin and lightweight • Zero clearance to combustibles • High temperature rated - 2000 °F • Robust, durable system • Approved in ICC-ES Report ESR 2213 (XL Product Benefits • Easy to remove or replace • Saves labor and time • Easy installation - No special tools requir d • Complete with threaded rods, wing nuts, • Built -in quality consistent from project to ivjcie. ---.. - _ • Clearly identified • No welding required at the job site • Access holes in the duct are made to match the doors r FireMaster® Grease Duct Access Door Systems VVED F CODE COMPLIA APPROVED_ wOCT�1 5 5 2011 City of Tukwilaa,�,, BUILDING DIVISION 2. Available Sizes 10° x 6" 12" x x 12" 18" x 14" il1 3. Performance Specifications 20 • r V. • Reference Standard Standard No. Performance Grease Duct Enclosure System ASTM E2336 Pass XL3 Section 16.1 - Non -com- bustibility ASTM E136 Pass 434- 6970 - 036-99X3 Section 16.2 - Fire Resistance (wall) ASTM E119 Pass XL3 Section 16.3 - Durability Test ASTM C518 Pass Section 16.4 - Internal Fire Test ASTM E2336 Pass XL3 Section 16.5 - Fire Engulfment (duct) ASTM E814/E119 Pass UL 1978 Pass XL2 336 Compliant Enclosure and Door System ireMaster F2- HT-XL3 Access Door 3 - Layers of FastWrap XL. on Door FireMaster F2-HT-XL3 Access Doors Opening size Ordering Code 10" x 6" Door Opening 434-6970-034-99X3 12- x 8" Door Opening 434-6970-035-99X3 16" x12- Door Opening 434 - 6970-037 -99X3 1r x 14" Door Opening 434- 6970 - 036-99X3 RECEIVED 312011 UL 1978 Compliant Enclosure and D.,.g'T CENTER' FireMaster F2-HT-XL2 Access Do-- 2 - Layers of FastWrap XL on Doc...—. FireMaster F2-HT-XL2 Access Doors Opening sae Ordering Code 10' x 6" Door opening 434- 6970-034 -99X2 1r x 8" Door Opening 434 - 6970-035-99X2 16- x 12' Door Opening 434 - 6970-037-99X2 18" x 14- Door Opening 434-6970-036-99X2 • t -.� 4. Installation: Materials and Equipment: • FireMaster Pre - insulated Access Door — Complete with: - DuctMate F2 -HT access door with 2300 °F high temperature gasket - Template to cut correct access opening sized to fit the supplied door - Extended all -thread rods, attached to inner 16 gauge plate - Inner wing nuts to tighten access door and pro- vide grease tight seal - 2 or 3 layers of Insulation depending on XL2 or XL3 system supplied - Outer 16 gauge insulation cover, with code pre- scribed signage - Outer wing nuts required to tighten insulation cover against duct • Minimum 3° wide aluminum foil tape • Insulation knives General: Preparation of the grease duct enclosure system and duct to receive FireMaster pre - insulated access door: Prior to installation of the FireMaster grease duct enclosure system, use the provided cut -out template to mark and cut an opening in the duct at building code or specification pre- scribed locations. Install the FireMaster duct enclosure sys- tem according to the Thermal Ceramics installation instruc- tions. Cut the layers of insulation above the access opening to the same size as the access opening. Next, cut the inte- rior layer of insulation 3f larger on all sides to accommodate the actual size of the access door and first layer of insulation. ASTM E 2336 compliant systems will have 2 layers of duct enclosure insulation on the duct which will require that the exterior layer of insulation be cut 114" larger on all sides than the inner insulation layer to provide a tight fit against the overlaps built into the pre - insulated access door. Repair cut edges of duct insulation with minimum 3" wide aluminum foil tape. Installation of the FireMaster pre - insulated access door: Remove the insulation pack and outer cover plate from the pre - insulated DuctMate F2 -HT door. Holding the DuctMate F2 -HT access door, loosen the inner wing nuts to open a gap between the inner 16 gauge plate and the 2300 °F white gas- ket materials. Fit the inner 16 gauge steel panel inside the access opening by tuming at a slight angle to clear the access opening. Center the inner 16 gauge steel plate with- in the opening, and tighten the wing nuts to hand -tight. Install the insulation pack and 16 gauge outer cover plate over the all -thread rods. Tighten the provided wing nuts against the 16 gauge insulation cover plate until hand -tight. FireMaster preinsulated access doors are provided with a 16 gauge outer cover plate with building code required signage "Access Door — Do not obstruct". FireMaster® FastWrap® XL Prefabricated Access Door Systems Commercial Kitchen Grease Duct Enclosure System FireMaster F2-HT-XL3 Door System NOTE Available from Thermal Ceramics FireMaster Distributors. Legend 1 DuctMate F2 -HT Access Door with 2300 °F gasket 2 All thread rods 3 Installation pins with speed dips 4 FireMaster FastWrap XL blanket with minimum 1° overlaps and all edges sealed with aluminum tape 5 Wing nuts and washers 6 Outer cover plate labeled Note: Label Required "Access Door" Do Not Obstruct www.thermalceramics.com 08.08/714206 Traditional bulky protection with gypsOitiv • • 4 WthiFiR .® bamer wrap . . RECEIVE AUG 31 2011 ERMITCEN u l k'Li cfo n t ;iv' e o Grease Duct Listings for 615+ Fire Resistive Rating 5+ 1or2 hours Duct System, Enclosure System Intertek (OPL) 2 layers of 3M'" Are Barrier Duct Wrap 615 +, 3" and p6mm3" ) (7 perimeter 6mm) 3MU/FRD 120 -19 longitudinal overlaps 3MU/FRD 120-18 Testing ASTM E 2336 / ICC ES AC101 Surface Burning Characteristics (ASTM E 84 for 615 +) Product 1f. Flame Spread Smoke Developed Codes & Standards for 615 +, Air Duct Standards for the Installation of Air Condition and Ventilating Systems, 2009 Ed. NFPA 92B Standard for Smoke Management Systems in Malls, Atria, and Large Spaces, 2005 Edition — Section 7.5.2 International Mechanical Code®, 2006 Edition — Section 513.10.2 This is ony a partial list of codes and standards. Go to 3M.com/firestop or speak to your authorized 3M distributor orsales representative at 1- 800 - 328 -1687 3M'" Fire Bonier Duct Wrap 615+ 3M- Fire Barrier Duct Wrap 615+ 3M"" Are Barrier Plenum Wrap 5A 3M- Fire Barrier PION= Wrap 5A *1.5" x 24" x 25' (38mm x 60.9cm x 762cm) *1.5 "x48 "x25' (38mm x 121.9cm x 762cm) .5" x 24" x50' (38mm x 121.9cm x 1524cm) 1 451bs. 20 kg. 90 lbs. 40 kg. 45 lbs. 20 kg. 90 Ms. 40 kg. .5" x486 x25' 2 (12.7nim x 121.9cm x 762cm) 3 M ' s G r e a s e , Chemical F u m e a n d Ventilad nAir Duct listings all have affiliated Through - Penetration design listings that comply with ASTM E 814. Go to 3M.conv4irestop or speak to your authorized 3M distributor or sales representative at 1- 800- 328 -1687 for more information. Ventilation Air Duc Fire Resistive Enclosure Duct Rating System Listings for 615+ (tested to ISO 6944) 1or2 hours 1 layer of 3M'" Fire Barrier Duct Wrap 615+, 3" (76mm) perimeter and 3MU/FRD- longitudinal 120-15 overlap Through- Listing System Penetration System Agency V -27 W -L -7180, W -J -7104 F -C -7054 UL 3MU/PH 60 -03, 3MU/PV 120 -23, 31VIi/PV 120 -25 Intertek (OPL) This is onlya partial ILst of systems drat use Duct Wrap 615+. For complete infomration visit www.3M.correstop. Codes & Standards for 615 +, Grease Duct NFPA 96, 2008 Edition NFPA 90A, 2002 Edition International Mechanical Code ®, 2003 Edition, Section 506.3.10 This is ony a partial list of codes and standards. Go to 3M.com/irestop or speak to your authorized 3M distributor or sales representative at 1 -800- 328 -1687 Grease Duct Vet�biatkxxt Air Duct Life Safety Duct (Stair Pressurization, Smoke, Exhaust, etc.) Plenum Applit ions • • Note: Consult individual project plans for which codes and standards apply. *In accordance with the tolerances in ASTM C 892 Standard Specification for High- Temperature Aber Blanket Thermal Insulation ASTM C 518 ASTM C 1338 ASTM E 84 ASTME119 ASTM E 136 ASTM E 814 ASTM E 2336 tFPA 252 (IL 910) UL 1887 ISO 6944 • • • • • • Product 3M"' Are Barrier Duct Wrap 615+ Product Number 615+ Description 3M"' Fire Barrier Duct Wrap 615+ for grease and air duct protection Roll Size 24" W x 25' L UPC Number 000-51115-18799-5 Packaging 1 4 Price Unit Roll 3M" Fire Barrier Dud Wrap 615+ 3M'" lire 8atiner IhrCt 815+ tilr grease and air duct tarr�lediaft 48 W x 25' L 000 61115 -18 8- 1 2 Auq 3M"' Fire Barrier Plenum Wrap 5A 3M'" Are Barrier Plenum Wrap 5A for plastic pipe protection 24" W x 50' L 000-51115-16513-9 1 8 Roll Ar" Fn Barrier Plenum Wrap 5A 5A 8M"" lire Barrier Plenu n Wrap 5A for plBStic p e 46' W x 25 L Otltt- 51115 -If4 Roil BATTS /ND BLANKETS FOR USE N FIRE RESISTIVE DUCT /CSF IN FS SEE Ll F9E RESISTANCE DIRECTORY 9069 3M US1E0 DUCT NSUATION 9069 UifIED F#IESTOP SYSTEMS FFESTOP SYSTEMS Warranty and Limited Remedy: 3M warrants that each 3M Are Protection Product will be free from defects in material and manufacture for 90 days from The date of purchase from 3M's authorized distributor. 3M MANS NO OTHER EXPRESS 011 M 'LWD WARRANTIES, INCLUDING ANY NAMED WARRANTY OF AEItCHANTABN.RY OR FITNESS FOR A PARTICU.AR PURPOSE tt a 3M product does not conform to this warranty, The sole and SEE MFTERTIX DIRECTORY off INTEITLEX DIRECTORY exclusive remedy is, at 3M's option, replacement of the 3M product or refund of the purchase price. Limitation of uabiaty: Except where prohibited by law, 3M will not be liable for any loss or damage arising from the 3M product, whether direct, indirect special, incidental or consequential, regardless of the legal theory asserted. Building and Commercial Services Division 3M Center, Building 223 -2N -21 St. Paul, MN 55144 -1000 Ph. 800 -328 -1687 3M.com /firestop Please recycle. Printed in U.S.A. Cr 3M 2009. All rights reserved. 98- 0213 - 4600 -6 (99.5)ii 3M is a trademark of 3M company. NFPA 101 and Life Safety Code are trademarks of the National Fire Protection Association. International Mechanical Code and International Building Code are trademark of the International Code Council. All other trademarks are the property of their respective owners. omma. 7Actuak 2'x2' (610mmx610mmr; 1T'x4'(610mmx 23 -3/4° x 23 -3/4' 23 -3/4' x 47 -3/4° 2.2 Ibs.lsq. ft UL G25 1 -112 Hour 219 mm) Description Gridstone BRAND CleanR Gypsum CeilinFane foFiuse in systems designeclaar4 requiring high levatf air di‘litiess for airborne partiakite lei eMhe panels are sealeti on the faceard back with a 2 -mil rigid vinyl' g inate. The edges are factoryy;ialed with a coating that encapsu .fates the exposed edges providing a completely sealed panel. Applications Gridstone CleanRoom panels are for use in systems designed for areas requiring high levels of air deanliness for airbome particulate levels such as dean rooms and dean zones. Gridstone panels are accepted by the USDA for use in food service and food processing areas. For use in systems, Class 100,000, 10,000, 1,000 and 100 per Federal Standard 209E "Airbome Particulate Cleanliness Classes in Clean Rooms and Clean Zones." Features/Ben t`lg Gridstone CleanRoom panels rigid gypsum core prevents sagging and warping problem., ® Common dirt and stains can be iL a removed widl•mild soap and water 10 A non - combustible gypsum core assures fire safety with 1-1/2 - and 2 -hour fire rating achievable depending on installation. 15 -year Limited Warranty. Installation Gridstone CleanRoom panels should be installed in a gasketed grid system using hold -down dips. Recommended use of GordorrDS -20 Gasket Seal System orEequivalent gasket sealed grid systems :designed for dean room applications. If panel cuts are required, exposed core should be sealed to maintain the performance of the system. Limitations MI Do not install panels in areas exposed to extreme or continuous moisture. 13 Overlaid insulation may cause excessive panel deflection and is not recommended where high humidity is likely to occur. BumuhRharater'stiaiPer'X►STM E 84) ITIlame Sp?eacf;;VZt :Smoke Developed: 0 Class: A Sound.Atteriu n (RerAS111 `E 1414) CeirulAtfebuati&)„ Glass (CAC)-46 dB, NGC Report 46098001 tight Refl ettahce: LR 1 (75% or greater) PRODUCT.SPECIFICATIONS': Gridstone BRAND Gypsum Ceiling Panels conform to: ASTM C 1396, Type X Class 1 ASTM E 1264, Type.XX, Patterns E, G PACKAGING 2' x 4' GB5030 4 pcs/bundle 32 sq. ft. f t. 40 bundles/unit 2' x 2' GB5040 4 pcsibundle 16 sq. ft 2 80 bundles/unit The double- banded bundles, long corner protectors and stretch wrap ensure quality on arrival. REVIEWED CODE COMPLIANCE PP OVER SEP o 2 p, ' B, City of Tukwila NG >QIVISION RECEIVED � � � PERMIT CENTER 4YPSUM;PANE jT URED;CEILWAS Guide Specification • '" "�� rte'' •�- {� t. ,I4ationa Gypsum Company Note : -The; Ping panel ilk spec ific 119. ose ots guide ducts aht(0insta • 'ect. Contact atio b - gage is to assist the specifier in correctly specifying oti, ° - specifier needs to edit these guide specifications to fit the Gypsum Company to assist in appropriate product selections. otes,40, . ded tit (italicized recktext) , - inclik ed to provide assistance in selecting appropriate text for a Spe: don. [Bold text] indicat:: a selection is required. Text in the brackets may not be the only le, bu : recommended or common selections_) { 1.1 T 1 - GENERAL A. SECTION 09 5613 GYPSUM -PANEL TEXTURED CEILINGS SECTION INCLUDES Gypsum Ceiling Panels B. Hi- Strength Gypsum Ceiling Panels C. Cleanroom Gypsum Ceiling Panels 1.2 PERFORMANCE CRITERIA (Specifier Note: The Gold Bond BRAND Gridstone Fire - Shield Gypsum Ceiling Panels and the Gold Bond BRAND Gridstone CleanRoom Gypsum Ceiling Panels can be used to achieve a rated ceiling assembly.) A. Ceiling Assembly Fire - Resistance Rating: [1 -1/2 -Hour per UL Assembly G259] [2 -Hour per UL Assembly G222] PART 2 - PRODUCTS 2.1 MANUFACTURER / PRODUCTS (Specifier Note: Throughout Part -2 maintain brand names when proprietary specification is acceptable. Use generic term when project must be competitively bid. CONFIRM product requirements and characteristics prior to listing products of other manufacturers.) A. Basis of Design: Products of National Gypsum Company. 2.2 GYPSUM CEILING PANELS (Specifier Note: Gridstone Fire - Shield panels are ideal for interior and unexposed exterior ceiling applications such as soffits, parking garages, kitchens and baths. They are accepted by the USDA for use in food service and food processing areas.) A. Basis of Design: Gold Bond® BRAND Gridstone® Fire- Shield® Gypsum Ceiling Panels. 1. Type X, Panel Physical Characteristics a. Core: Fire and sag resistant gypsum core b. Size (nominal): [2 feet x 2 feet] [2 feet x 4 feet] Project Name /Project Number /11- Feb -10 Gold Bond® GRIDSTONE GYPSUM CEILING PANELS National Gypsum Company .1 c. Overall Thickness 1/2 inch d. Surface: 2 mil. white, stipple - textured vinyl laminate e. Sound Attenuation: Class (CAC) -46 dB when tested in accordance with ASTM E1414 Standard Test Method for Airbome Sound Attenuation between Rooms Sharing a Common Ceiling Plenum f. Panel complies with requirements for Type X, Class 1 of ASTM C 1396 Standard . Specification for Gypsum Board g. Panel complies with requirements for Type XX, Patterns E, G of ASTM E 1264 Standard Classification for Acoustical Ceiling Products h. Light Reflectance: LR 1 (75% or greater) Surface Burning Characteristics when tested in accordance with ASTM E 84, Standard Test Method for Surface Buming Characteristics of Building Materials: 1) Flame Spread: 5 2) Smoke Development 0 2.3 HI- STRENGTH GYPSUM CEILING PANELS (Specifier Note: Gridstone Hi- Strength panels are ideal for interior and exterior ceiling application in protected, well - ventilated spaces that receive intermittent exposure to moisture such as soffits, parking garages, and other non -fire related ceiling systems. They are accepted by the USDA for use in food service and food processing areas.) A. Basis of Design: Gold Bond® BRAND Gridstone® Hi- Strength Gypsum Ceiling Panels. 1. Panel Physical Characteristics a. Core: Regular, high strength, sag resistant gypsum core b. Size (nominal): [2 feet x 2 feet] [2 feet x 4 feet] c. Overall Thickness: 5/16 inch d. Surface: 2 mil., white, stipple- textured vinyl laminate e. Sound Attenuation: Class (CAC) -41 dB when tested in accordance with ASTM E1414 Standard Test Method for Airborne Sound Attenuation between Rooms Sharing a Common Ceiling Plenum f. Panel complies with requirements for Class 1 of ASTM C 1396 Standard Specification for Gypsum Board g. Panel complies with requirements for Pattems E, G of ASTM E 1264 Standard Classification for Acoustical Ceiling Products h. Light Reflectance: LR 1 (75% or greater) i. Surface Buming Characteristics when tested in accordance with ASTM E 84, Standard Test Method for Surface Buming Characteristics of Building Materials: 1) Flame Spread: 5 2) Smoke Development: 0 2.4 CLEANROOM CEILING PANELS (Specifier Note: Gridstone Cleanroom panels are ideal for areas requiring high levels of air cleanliness for airborne particulate levels such as clean rooms and clean zones. They are accepted by the USDA for use in food service and food processing areas) A. Basis of Design: Gold Bond® BRAND Gridstone® CleanRoom® Gypsum Ceiling Panels. 1. Type X, Panel Physical Characteristics a. Core: Fire and sag resistant gypsum core b. Size (nominal): [2 feet x 2 feet] [2 feet x 4 feet] c. Overall Thickness: 1/2 inch Project Name /Project Number/1 1-Feb-10 2 Gold Bond® GRIDSTONE GYPSUM CEILING PANELS National Gypsum Company d. Surface: 2 mil. white, stipple- textured vinyl laminate sealed on the face and back. The edges are factory sealed with a coating that encapsulated the exposed edges, providing a completely sealed panel e. Sound Attenuation: Class (CAC)-46 dB when tested in accordance with ASTM E1414 Standard Test Method for Airbome Sound Attenuation between Rooms Sharing a Common Ceiling Plenum f. Panel complies with requirements for Type X, Class 1 of ASTM C 1396 Standard Specification for Gypsum Board g. Panel complies with requirements for Type XX, Pattems E, G of ASTM E 1264 Standard Classification for Acoustical Ceiling Products h. Light Reflectance: LR 1 (75% or greater) i. Surface Buming Characteristics when tested in accordance with ASTM E 84, Standard Test Method for Surface Burning Characteristics of Building Materials: 1) Flame Spread: 5 2) Smoke Development: 0 2.5 SUSPENSION GRIDS (Specifier Note: Gridstone panels should be used with compatible suspension grid systems. COORDINATE panels and grid systems.) A. [Hi- Strength] [Gypsum ] Ceiling Panels 1. Description: [Exposed grid systems] [15/16 inch exposed grid systems with tee grids] 2. Finish: [Clear anodized] [White powder coat] [Custom color]. B. Cleanroom Gypsum Ceiling Panels: 1. Product: [Gordon -DS -20 Gasket Seal System] [Insert Product Name] 2. Description: Gasketed grid system with hold -down clips. 3. Finish: [Clear anodized] [White powder coat] [Custom color]. PART 3 - EXECUTION ( CORDINATE Preparation and Installation requirements with the desired ceiling assembly.) 3.1 INSTALLATION A. Install in accordance with manufacturer recommendations. B. [Hi-Strength ][Gypsum ]Ceiling Panels 1. Panels drop in place in standard exposed grid systems. C. Cleanroom Gypsum Ceiling Panels 1. Panels should be clipped down into a gasketed grid system. 2. If cuts are required, exposing core should be sealed to maintain the performance of the system. 3.2 CLEANING A. Removed dirt and dust with mild soap and water. Project Name /Project Number/1 1-Feb-10 3 Gold Bond® GRIDSTONE GYPSUM CEILING PANELS National Gypsum Company • - DISCLAIMER: National Gypsum Company Guide Specifications have been written as an aid to the professionally qualified specifier and design professional. The use of this information requires the professional judgment and expertise of the qualified specifier and design professional to adapt the information to the specific needs of the building Owner and the project; to coordinate with the design professional's construction document process, and to meet the applicable building codes, regulations and laws. National Gypsum diims any warranty, expressed or implied, including the warranty of fitness for a particular purpose of the pioduct for a project. © 2010 National Gypsum Properties, LLC Project Name /Project Number /11- Feb -10 4 Gold Bond® GRIDSTONE GYPSUM CEILING PANELS National Gypsum Company PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M11 -120 DATE: 08 -31 -11 PROJECT NAME: SHABELLE MINIMART SITE ADDRESS: 14822 TUKWILA INTERNATIONAL BL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: Ilding Ivlsion ett■ Public Works Fire Prevention Structural Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete DUE DATE: 09-01 -11 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required n No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 09-29-11 Approved n Approved with Conditions IS Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center. Use Only ' CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip doc 2 -28 -02 • CITY OF TUKWILA Department of Community Development 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431 -367o FAX (206) 431 -3665 E -mail: tukplanaci.tukwila.wa.us Permit Center /Building Division 206 431 -3670 Public Works Department 206 433 -0179 Planning Division 206 431 -367o AFFIDAVIT IN LIEU OF CONTRACTOR REGISTRATION PERMIT NO: M l l ' t (/ STATE OF WASHINGTON) ) ss. COUNTY OF KING ) :1 b r. kis Jy E`-`" 00-v , states as follows: [please print name] 1. I have made application for a permit from the City of Tukwila, Washington. 2. I understand that state law requires that all building construction contractors be registered with the State of Washington. The exceptions to this requirement are stated under Section 18.27.090 of the Revised Code of Washington, a copy of which is printed on the reverse side of this Affidavit. I have read or am familiar with RCW 18.27.090. 3. I understand that prior to issuance of a permit for work which is to be done by any contractor, the City of Tukwila must verify either that the contractor is registered by the State of Washington, or that one of the exemptions stated under RCW 18.27.090 applies. 4. In order to provide verification to the City of Tukwila of my compliance with this requirement, I hereby attest that after reading the exemptions from the registration requirement of RCW 18.27.090, I consider the work authorized under this permit to be exempt under number . and will therefore not be performed by a registered contractor. 5. I understand that the licensing provision of RCW 19.28.161 through 19.28.271 shall not apply to persons making electrical installations on their own property or to regularly employed employees working on the premises of their employer. The proposed electrical work is not for the construction of a new building for rent, sale or lease. I understand that I may be waiving certain rights that I might otherwise have under state law in any decision to engage an unregistered contractor to perform constructio k. Owner /Owner's Agent* Signed and sworn to before me this day of . "_/ ,, C�-v V ltd- i , 20 1J, ' �.L►1�1 /� NOTARY PUBLIC in and for the tate of Washington Residing at )2_IP2 , County Name as commissioned: S . , Era My commission expires: \0- 18.27.090 Exemptions, The reg�tion provisions of this 1. An authorized representative of the United States government, the state of Washington, or any incorporated city, town, county, township, irrigation district, reclamation district, or other municipal or political corporation or subdivision of this state; 2. Officers of a court when they are acting within the scope of their office; 3. Public utilities operating under the regulations of the utilities and transportation commission in construction, maintenance, or development work incidental to their own business; 4. Any construction, repair, or operation incidental to the discovering or producing of petroleum or gas, or the drilling, testing, abandoning, or other operation of any petroleum or gas well or any surface or underground mine or mineral deposit when performed by an owner or lessee; 5. The sale of any finished products, materials, or articles of merchandise that are not fabricated into and do not become a part of a structure under the common law of fixtures; 6. Any construction, alteration, improvement, or repair of personal property performed by the registered or legal owner, or by a mobile /manufactured home retail dealer or manufacturer licensed under chapter 46.70 RCW who shall warranty service and repairs under chapter 46.70 RCW; 7. Any construction, alteration, improvement, or repair carried on within the limits and boundaries of any site or reservation under the legal jurisdiction of the federal government; 8. Any person who only furnished materials, supplies, or equipment without fabricating them into, or consuming them in the performance of, the work of the contractor; 9. Any work or operation on one undertaking or project by one or more contracts, the aggregate contract price of which for labor and materials and all other items is less than five hundred dollars, such work or operations being considered as of a casual, minor, or inconsequential nature. The exemption prescribed in this subsection does not apply in any instance wherein the work or construction is only a part of a larger or major operation, whether undertaken by the same or a different contractor, or in which a division of the operation is made into contracts of amounts less than five hundred dollars for the purpose of evasion of this chapter or otherwise. The exemption prescribed in this subsection does not apply to a person who advertises or puts out any sign or card or other device which might indicate to the public that he or she is a contractor, or that he or she is qualified to engage in the business of contractor 10. Any construction or operation incidental to the construction and repair of irrigation and drainage ditches of regularly constituted irrigation districts or reclamation districts; or to farming, dairying, agriculture, viticulture, horticulture, or stock or poultry raising; or to clearing or other work upon land in rural districts for fire prevention purposes; except when any of the above work is performed chapter do not apply by a registered contractor; 11. An owner* who contracts for a project with a registered contractor, except that this exemption shall not deprive the owner of the protections of this chapter against registered and unregistered contractors. The exemption prescribed in this subsection does not apply to a person who performs the activities of a contractor for the purpose of leasing or selling improved property he or she has owned for less than twelve months; 12." Any person working on his or her own property, whether occupied by him or her or not, and any person working on his or her personal residence, whether owned by him or her or not but this exemption shall not apply to any person who performs the activities of a contractor on his or her own property for the purpose of selling, demolishing, or leasing the property; 13. An owner* who performs maintenance, repair, and alteration work in or upon his or her own properties, or who uses his or her own employees to do such work; 14. A licensed architect or civil or professional engineer acting solely in his or her professional capacity, an electrician certified under the laws of the state of Washington, or a plumber certified under the laws of the state of Washington or licensed by a political subdivision of the state of Washington while operating within the boundaries of such political subdivision. The exemption provided in this subsection is applicable only when the person certified is operating within the scope of his or her certification; 15. Any person who engages in the activities herein regulated as an employee of a registered contractor with wages as his or her sole compensation or as an employee with wages as his or her sole compensation; i6. Contractors on highway projects who have been prequalified as required by RCW 47.28.070, with the department of transportation to perform highway construction, reconstruction, or maintenance work; 17. A mobile /manufactured home dealer or manufacturer who subcontracts the installation, set -up, or repair work to actively registered contractors. This exemption only applies to the installation, set -up, or repair of the mobile /manufactured homes that were manufactured or sold by the mobile /manufactured home dealer or manufacturer, 18. An entity who holds adaljid,e1 ttgical.contractor's license under chapter }9.28, RC'W�thattenploys a certified journeyman electricaal`i, ,3grq`fied''i }dp*tetfa1 specialty electrician, or an elettricclttrainee Meeting the requirements of chapte69.28 RCW to p rforin plumbing work that is incidentally;, directly, and immediately appropriate to the likekind• replacement of a household appliance or other smafl`,household utilittion equipment that requires limited el'e r' i> grower ariPhmited waste and /or water connections: A0Inctrical trainee must be supervised by a certified electricians while performing plumbing work. • Per Washington State Department of Labor and Industries, lessee has been interpreted to be equivalent to owner for the purpose of these exemptions. DEISM MIME= ERISISSENSIEDI EMBEIMMEMIllialiniSESSIMMEsswas Other business Legal Discriptio ADAMS HOME TRS 1ST ADD POR OF LOTS 8, 9 & 10 - BEG NE CORNER OF LOT 10 TH S 01 -05 -55 W 129.75 FT TO POB TH N 88 -51 -15 W 147.45 FT TH N 70 -39 -43 W 111 FT TH N 76 -59 -24 W 54.19 FT TH S 20 -06 -26 W 99.51 FT TH S 76 -24 -25 E 56.39 FT TH S 70 -35-04 E 73.84 FT TH S 87-57-33 E 213.18 FT TO EAST LINE OF LOT 10 TH N 01 -05 -55 E 86.94 FT TO POB LESS ST HWY - AKA LOT B OF CITY OF TUKWILA BOUNDARY LINE AWN() 90-4 BLA RECORDING NO 9009190344 EXISTING Restroom RETAIL CHECK OUT Dean Super Runner Gas Fryer (Natural Gas) Or Equal Coops Part No 8R42G•C•NG Mfg Part No SR42G•CSTR Natural Gas Fryer w!casters 35-43 Ib. capacity 105,000 BTU/hr input Full size 14" x 14" fry area Wide cold zone Millivolt pilot system requires no electricity Stainless steel frypot, front, door, and backsplashlflue cover; aluminized sides Overall dimensions: 15.5 "W x 29.25 "D x 45 "H (35" work height) Equipment List ARRB Radiant Broilers with Range Stainless Steel rugged exterior body. 6" deep front stainless steel bultnose landing ledge/work space. 6" High Polished chrome adjustable steel legs. Heavy gauge welded frame construction. 6" High stainless steel stub back In lieu of high riser. 32,000 BTU open bunters, industry's highest, High temperature knobs Beverage Air KR48 -1AS Reach -in Refrigerator Or Equal Manufacturer: Beverage Air Description: Reach -in Solid Model : Finish KR48 -1AS: Stainless Steel Doors: 2 Shelves /Dividers: 6 Dimensions: 54" x 31" x 82" Cubic Ft: 44.9 Weight (lbs.): 521 Power: Volts: 115, Amps: 9.4, HP: 1/3 '1 ENTRY & EXIT EXISTING RETAIL AND MARKET AREA 3'— lit- -f Public Health Standard Notations NOTATION P.H. ALL WALLS SHALL BE FINISHED WITH SEMI GLOSS PAINT UNLESS OTHER WISE NOTED: FLOORING: (WASHABLE SURFACE). ALL DINING FLOOR AREA ,DISH WASHING, KITCHEN, FOOD PREP AREA SHALL BE TILE OR LINOLEUM FLOORING 4D 7*• NOTATION P.H CEILING, IN WASH AND KITCHEN AREA IS GYP. BOARD PAINTED WITH SEMI-GLOSS . NOTATION P.H. UNLESS NOTED ON THE PLANS ALL SINKS SHALL CONNECT DIRECTLY TO SEWER LINE WHICH CONNECTS TO CITY SEWER. (3 COMPARTMENT SINK) WASH SINK MODEL# S.S.P.INC -NSF Customized (GREASE TRAP INSTALLLED FOR WASH SINK) MODEL# 30GAL. REVISIONS "1 No changes shall be made to thr scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new lrl n s bmitt -1 and may include additional plan f:^.3. MI ARI2G 36" 411, 2 -261/1" Standard oven 220,000 Or Equal memo FEATURES STANDARD O he Heavy Duty Restaurant Range Series ' y American Range was designed r continuous rugged use and performance. All the latest technology is incorporated o give you the best value for your money. You wanted power! We ive it to you with 32,000 BTU per open op burner, and 20,000 BTU per griddle urner. Something you normally see h institutional series ranges. All stainless teel external body Is a standard fixture for longevity and easy cleaning. uality, dependability and customer atisfaction makecan Range the ultimate choice. Laurance Anthone MSM PM 1 ST A CFO REVIEWED FO CODE COMPLIANCE APPROVED '- SEP 022011 SEP City For ACI Cognitive Commercial Project Management 1 EUILDII 32321 11th Ave SW Federal Way, WA 98023 Phone: 425-749-2613 Fax: 425-484-8485 Website: www:anthonecapitaiinc.net < http : //www.anthonecapitaiinc.net/> Definitfons Project Manager: For property development 1s not general contractor. Is a mediator between owner and professional service provider perform as an agent for property owners to the required munidpals for the purpose of permitting Projects. (It is understood and agreed thatAa is Not a general contractor, as that word Is used in RCW 11£27.020 etseq. Aei is simply a project manager, not a contractor. if required.a registered contractor will be retain to perform work at owners choice or when required by municipalities when allcermits are issued)- FILE COPY Pony* No., 1\i\ , an turn approval Is stmt to errors and Approval of construction documents does not authorize the violation of any adopted code or Drama ice. Receipt of approved Weldil grid i ' Wier ged: Ems..■ ► 7' -1 WORK PROPOSED. DASHEDLINE [ ---=_- Soap Dispen Cooler Refrigeration Unit 1 LOT B MAIN ADDRESS 14816 TUKWILA INTERNATIONAL BLVD 213 r SEPARATE PERMIT REQUIRED FOR: ❑ Mechanical 0 Electrical -. Plumbing bk GGas Piping City of Tukwila BUILDING DIVISION 12 —9 120 Deli Floor And Mechanical Hood Plans SCALE 1/4" = 1' - 00" Unless Otherwise Noted nts lY.�,7.1US7�L7Jwin'Ai�"� Assessor Parcel Records: 0041000142 ACI Cognitive Commercial Project Management PR (425) 749 -2613 FAX (425) 484 -8485 AUTHORIZED SIGNATORY FO; SHABELLE MINI MART ACCEPTANCES leES ' 1S / 2 010 �+. NONE FOR THIS PRWE CT RECEIVED; AUG 31 2011 PERMIT CENTER ENGINEERING STAMP ACI SEAL VOID WITHOUT SEAL TIC -1 PAGE- 1 4i g•:'cF.'fiS.. uNifk.r..r riiia kA���'.t7�`sC Assessor Parcel Records: 0041000142 ICC IMC 2009 SECTION 506 COMMERCIAL KITCHEN HOOD VENTILATION YSTEM DUCTS AND EXHAUST EQUIPMENT 06.3 Ducts serving Type I hoods. ype I exhaust ducts shall • e independent of all other - xhaust systems except as rovided in Section 506.3.5. ommercial kitchen duct systems • erving ype I hoods shall be designed, onstructed and installed In ccordance with Sections 506.3.1 hrough 506.3.12.3. .06.3.1 Duct materials. Ducts • erving Type I hoods shalt • e constructed of materials in • ccordance with Sections .06.3.L1 and 506.3.1.2, .06.3.1.1 Grease duct materials. rease ducts serving ype I hoods shall be onstructed of steet not less han 0.055 inch (1.4 mm) (No. 16 age) in thickness or stainless teel not less than 0.0450 inch 1.14 mm) (No. 18 Gage) in hickness. ICC IMC 2009 507.13. Capacity of hoods. Commercial food service hoods shaft exhaust a minimum net quantity of air determined in accordance with this section and Sections 507.13.1 through 507.13.4. The net quantity of exhaust air shall be calculated by subtracting any airflow supplied directly to a hood . cavity from the total exhaust flowrate of a hood. Where any combination of heavy - dutyv, medium -duty and light -duty cooking appliances are utilized under a single hood, the exhaust rate required by this section for the heaviest duty appliance covered by the hood shall be used for -the entire hood. 507.13.3 Medium -duty cooking appliances. The minimum net airflow for Type I hoods used for medium -duty cooking appliances shall be determined as follows: Type ofHood CFMper linear foot of hood Backshelf /pass -over 300 Doubte island canopy <per side) 300 Eyebrow 250 Single island canopy 500 Wall- mounted canopy 300 IMC 2009 506.3.2.3 Duct -to- exhaust fan connections. Ductto- exhaust fan connections shall be flanged and gasketed at the base of the fan for vertical discharge fans; shall be flanged, gasketed and bolted to the inlet of the fan for side -inlet utility fans; and shall be flanged, gasketed and bolted to the inlet and outlet of the fan for in -line fans. 50632.4 Vibration isolation. A vibration isolation connector for connecting a duct to a fan shall consist of noncombustible packing in a metal sleeve joint of approved design or shall be a coated - fabric flexible duct connector listed and labeled for the application. Vibration isolation connectors shall be installed only at the connection of a duct to a fan inlet or outlet. Dayton 4YY16 (USED) Type: UP Blast Exhaust Ventilator Direct Drive 14 3/4' Impetter 36'x1' Weather Seat Fire Resistan Self Adhesive Power Junction Note: The installer must and shall have all duct work inspected and light tested prior to covering duct IMC 2009. 506.3.2.5 Grease duct test. Prior to the use or concealment of any portion of a grease duct system, a leakage test shall be performed. Ducts shall be considered to be concealed where installed in shafts or covered by coatings or wraps that prevent the ductwork from being visually inspected on all sides. The permit holder shall be responsible to provide the necessary equipment and perform the grease duct leakage test.Alight test shall be performed to determine that all welded and brazed joints are liquid tight. A light test shall be performed by passing a lamp having a power rating of not less than 100 watts through the entire section of ductwork to be tested. The lamp shall be open so as to emit light equally in all directions perpendicular to the ductwalls.Atest shall be performed for the entire duct system, including the hood -to -duct connection. The ductwork shall be permitted to be tested in sections, provided that every joint is tested. For listed factory -built grease ducts, this test shall be limited to duct joints assembled in the field and shall exclude factory welds. 18 Gage Galvanized Sheet Metal Construction with E70 0.023 Welding Weldhnto tinuous On Ex Surface TYP.> 2,234 jaduPPort Bracket To Existing 2x12 Bolt and Loddng Washer TIP. 1 x 1/4" Fiat Steel Gray Non- Corrosive Paint _2" Centrifuge Ventilator (Pre -made) and installed Used 17' -10" 10 51__.3/1 2' -1� // Threaded d RodtGra Non- Corrosive Paint for Lo El 333 EXHAUST EXHAUST CLEANDUT Dayton 4YY16 (USED) Type: UP Blast Exhaust Ventilator Direct Drive 14 3/4' Impeller EEI EEE IEEE BEE FEE =sr 34x3/8 "e > . 5' Galv.. 34 x 34x 34' Angle Iron Bolt, Gray Non- Corrosive Paint E70 0.023 Welding Welding (Continuous Weld at Joints On Exterior Surface TYP.) " Zinc Bolt with locking washer BK H112 Channel 1" RD. Gaiv. Grease Drain Pipe %x-X" SC) Tubing" Flat Steel Gray Non - Corrosive Paint MAKEUP AIR L_ 4x4x96 Treated Timber Typical MAKEUP AIR 16 Gage Gaty. / Grease Reservoir Steel Gray Non - Corroslve Paint New Fire Rated Ceiling Tite MAKEUP! AIR JA Existing 2 x12 DF Dayton 7D638 (USED) Belt Drive Blower 12 5/8' Impeller 4/ -6„ Main Hood Construction Stainless Typical C Per -Made) Used KITCHEN PRODUCT SPECIFICATIONS 7C�IMOeeX Aging Panels «nronn to Om 1 ME 0 UK ASIM E INK, Tips 304 Patten £. 0 5" ASTM E 814 Fire Rating F And T Insulation tested to I STM E2336 for zero clearance, 1 and 2 hour shaft Fire Master FastWarp XL 2x2x3 Fiat Iron with E70 0.023 Welding Welding (Continuous Weld at Joints On Exterior Surface TYP.) 1x1, Flat Iron with E70 0.023 Welding Welding (Continuous Weld at Joints On Exterior Surface .TYP.) 96 "x 34x "18 Galvanized 18 Gage Sheet Metal Back (U) 3'x 3' xY' Support Mount Construction Stainless Typical Spot Weld With Z70 0.023 Welding Wire Continuous Seam IMC 2006 SECTION 507.2.1.1 Operation COMMERCIAL KITCHEN HOOD NORTH REVIEWED FOR CODE COMPLIANCE APPROVED SEP 0 2 2011 City of Tukwila BUILDING DIVISION 507.2.1,1 Operation. Type I hood systems shall be designed and installed to automatically activate the exhaust for whenever cooking operations occur. The activation of the exhaust fan shall occur through an interlock with the cooking appliances, by means of heat sensors or by means of' other approved methods. Dayton EXHAUST 4YY16 Hatch opening detail NTS IMC 2009 Makeup Air Duct 506.3.1.2 Makeup air ducts. Make up air ducts connecting to or within 14 -0es057.,ofla'Cypaftheockihall be constructed and installed in accordance with Sections 603.1, 603.3, ..603 4 R603:9 80 ' i6ai d'tb3:11:iiiict'ij insulation instaleed yi►ii'tbin i 8 kindba045' ) di Type I hood shall be noncombustible or shall :lie` lihstecttor the application. • • 506.3.2 Joints; seams and penetrations of grease ducts. Joints, seams and penetrations of grease ducts shall be made with a continuous liquid- tight weld or braze made on the external surface of the duct system. 506.3.2.1 Duct joint types. Duct joints shall be butt joints or overlapping duct joints of either the telescoping or bell type. Overlapping joints shall be installed to prevent ledges and obstructions from collecting grease or interfering with gravity drainage to the intended collection point. The difference between the inside cross- sectional dimensions of overlapping sections of duct shall not exceed 0.25 inch (6 mm) The length of overlap for overlapping duct joints shall not exceed 2 inches (51 mm). 506.3.2.3 Duct -to- exhaust fan connections. Ductto- exhaust fan connections shall be flanged and gasketed at the base of the fan for vertical discharge fans; shall be flanged, gasketed and bolted to the inlet of the fan for side -inlet utility fans; and shall be flanged, gasketed and bolted to the inlet and outlet of the fan for in-line fans. 5063.2.4 Vibration isolation. A vibration isolation connector for connecting a duct to a fan shall consist of noncombustible packing in a metal sleeve joint of approved design or shall be a coated -fabric flexible duct connector listed and labeled for the application. Vibration isolation connectors shall be installed only at the connection of a duct to a fan inlet or outlet. Deli Mechanical Hood Plans SCALE 1/2" = 1' - 00" Unless Noted IMC 2009 ICC IMC 2009 SECTION 508 COMMERCIAL KITCHEN MAKEUP AIR 508.1 Makeup air. Makeup air shall be supplied during the operation of commercial kitchen exhaust systems that are provided for commercial cooking appliances. The amount of makeup air supplied to the building from all sources shall be approximately equal to the amount of exhaust air for all exhaust systems for the building. The makeup air shall not reduce the effectiveness of the exhaust system. Makeup air shall be provided by gravity or, Mechanical means or both. Mechanical makeup air systems shall be automatically controlled to start and operate simultaneously with the exhaust system. Makeup air intake opening locations shall comply with Section 401.4. IMC 2009 SECTION 506.3.10 & 506.3.6 Grease Duct. 506.3.6 Grease duct clearances. Where enclosures are not required, grease duct systems and exhaust equipment serving a;Type I hood shall have a clearance to combustible construction of not less than 18 inches (457 mm), and shall have a clearance to noncombustible construction and gypsum wallboard attached to noncombustible structures of not less than 3 inches (76 mm). 506.3.10 Grease duct enclosures. A grease duct serving a Type I hood that penetrates a ceiling, wall or floor shall be enclosed from the point of penetration to the outlet terminal. A duct shall penetrate exterior walls only at locations where unprotected openings are permitted by the International Building Code. The duct enclosure shall serve a single grease duct and shall not contain other ducts, piping or wiring systems. Duct enclosures shall be either field- applied or factory - built. Duct enclosures shall have a fire- resistance rating not less than that of the floor assembly penetrated, but need not exceed 2 hours. Duct enclosures shall be as prescribed by Section 506.3.10.1, 506.3.10.2 or 506.3.10.3. 507.12 Canopy size and location. The inside lower edge of canopy -type Type I and II commercial hoods shall overhang or extend a horizontal distance of not less than 6 inches (152 mm) beyond the edge of the top horizontal surface of the appliance on all open sides. The vertical distance between the front lower lip of the hood and such surface shall not exceed 4 feet (1219 mm). GREASE DUCT TEST (2009 IMC 506.3.2.5) Prior to the use or concealment of any portion of a grease duct system, a leak test shall be preformed, Ducts shall be considered to be concealed where Installed in shafts or covered by coatings or wraps that prevent the ductwork from being visually inspected on all sides: The permit holder shall be .responsible : to provide the necessary equipment and perform the grease duct leakage test. A light test shall be performed to determine that all welded and brazed joints are liquid; tight. A light test shall be performed by passing a lamp having a power rating' of not less than 100 watts through the entire section of :ductwork to be tested. The lamp shall be open so as to emit light equally in all directions perpendicular the duct walls. Test shall be performed for the entire duct system, : including the hood -to -duct connections. The duct work shall be permitted to be tested in sections, provided that every joint is tested. For listed factory -built grease ducts, this test shall be limited to the duct joints assembled in the field hall include factory welds. 4x4 Treated Timber 2x2x3f6 angle Iron Bo.ted to Maslonary Exterior Wall. Bolted to Non- Bearing Partition Wall Imo C• =sZt —•— as • • a DELI SERVICE AREA Hood and Equipment Front View SCALE 1/2" SIIABELLE MINI MART RETAIL STORE AND DELI - 00" ACI Cognitive Commercial Project Management PH. (425) 749 -2613 FAX (425) 484 -8485 • HABELLE MINI MART �/ CCEPTANCES �`� ATE_ � _ /� _ /__ 2010 am .4 DESIGN RIGHTS BY ACI ALL CONTENT ARE NIT FOR REPLICATION BY ANY VOII AIEpR7�{R FOR CONSTRUCT= L OF BY ." '- i�I 514 21ST: UNDER TIC DESIGN RIGHTS BY ACI ALL CONTENT ONLY FOR NON STANDARD COUNTY DR CITY TEMPLATES vEN1 La. 0 ✓ l • O 1 NONE FOR THIS PROJECT RECEIVED -me 312011_. PERMIT CENTER ACI SEAL VOID WITHOUT SEAL anineasamtwout 110 The Management Corporation P., Comm.,daI Developments EC- 3 -2 PAGE— 2 PROJECT REVISION 1482207A3 -2010