Permit M11-130 - WESTFIELD SOUTHCENTER MALL - ICING
ICING 1003 SOUTHCENTER MALL Mi 1 -130 Parcel No.: Address: City If Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206 -431 -2451 Web site: http: / /www.TukwilaWA.gov MECHANICAL PERMIT 9202470010 1003 SOUTHCENTER MALL TUKW Project Name: ICING Permit Number: M11 -130 Issue Date: 10/05/2011 Permit Expires On: 04/02/2012 Owner: Name: Address: Contact Person: Name: Address: Email: Contractor: Name: Address: WESTFIELD PROPERTY TAX DEPT PO BOX 130940 , CARLSBAD CA 92013 KELVIN BATTLE 25500 74 AV S , KENT WA 98032 KELVIN@PMGHVAC.COM Phone: 425 - 251 -0356 PERFORMANCE HEATING Phone: 425 251 -0356 7649 S 180 ST , KENT WA 98032 Contractor License No: PERFOHA15ORT Expiration Date: 04/30/2013 DESCRIPTION OF WORK: REPLACE EXISTING SPLIT SYSTEM WITH NEW TO SERVE NEW TENANT Value of Mechanical: $16,500.00 Type of Fire Protection: UNKOWN Electrical Service Provided by: Permit Center Authorized Signature: Fees Collected: $391.81 International Mechanical Code Edition: 2009 ya/66,L; Z6/,1%( Date: /657// I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this permit. Signature: Date: Print Name: � , .► 17 -¢ This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -4/10 M11-130 Printed: 10 -05 -2011 • • PERMIT CONDITIONS Permit No. M11-130 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Readily accessible access to roof mounted equipment is required. 7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 8: Manufacturers installation instructions shall be available on the job site at the time of inspection. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IMC-4/10 M11-130 Printed: 10 -05 -2011 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Building Permit No. Mechanical Permit No. Plumbing /Gas Permit No. Public Iditorks Permit No. Project` No..' e only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION t003 Site AddressE 8 South Center Mall Tenant Name: ICING RETAIL STORE Property Owners Name: Westfield Property Tax Dept9n9800 Mailing Address: PO Box 130940 King Co Assessor's Tax No.: 9202 470010 ` Suite Number: m4 .5f'6 -Ct 43 2' New Tenant: If Yes ❑..No Carlsbad Ca 92013 City State Zip CONTACT PERSON - w o do we contact when your permit is read o be issued Name: Kelvin Battle Day Telephone: 425- 251 -0356 Mailing Address:25500 74th Ave S E -Mail Address: kelvin @pmghvac.com Fax Number:253 -867 -5775 Kent, City WA State 98032 Zip GENERAL CONTRACTOR INFORMATION - (Contractor Information for Mechanical (pg 4) for Plumbing and Gas ping (pg 5)) Company Name: Performance Heating & Air Conditioning Mailing Address: 25500 74th Ave S Kent, WA City State Contact Person: Kelvin Battle Day Telephone: 425- 251 -0356 E -Mail Address: kelvin @pmghvac.com Fax Number: 253- 867 -5775 Contractor Registration Number: PERFOHA 15ORT Expiration Date: 98032 Zip 4/30/12 ARCH TECT OF RECORD - All pl s must be wet stamped by Architect of Record Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: State Zip ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Recor Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Q Applications \Forms - Applications On Line \3 -2006 - Permit Application. doc Revised: 9 -2006 bh State Zip Page 1 of 6 MECHANICAL, PERMI4TINFQRIVI ATIONQ` a 20.64313670 MECHANICAL CONTRACTOR INFORMATION Company Name: Performance Heating and Air Conditioning Mailing Address: 25500 74th Ave S Contact Person: Kelvin Battle Kent WA City State Day Telephone: 425- 2581 -0356 E -Mail Address: kelvin @pmghvac.com Fax Number: 253 -867 -5775 98032 Zip Contractor Registration Number:PERFOHA15ORT Expration Date: 4/30/12 Valuation of Mechanical work (contractor's bid price): $_ 16,500.00 Scope of Work (please provide detailed information): REPLACE EXISTING SPLIT SYSTEM WITH NEW TO SERVE NEW TENANT. Use: Residential: New .... ❑ Replacem ent .... ❑ Com mercial: New .... ❑ Replacem ent .... Fuel Type: Electric x ❑ Gas ....❑ Oth er: Indicate type of mechanical work being installed and the quantity below: Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace <100K BTU Air Handling Unit >10,000 CFM 1 Fire Damper 0 -3 HP/I00,000 BTU Furnace >100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended /Wall /Floor Mounted Heater Ventilation System Wood /Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig /Cooling System Incinerator - Domestic Other Mechanical Equipment Cooling only split system Air Handling Unit <10,000 CFM Incinerator — Comm/Ind o Wpplications\Forms- Applications On Lnel3 -2006 - Permit Application.doc Revised: 9 -2006 bh Page 4 of 6 • • PEE MIST niliC TI'af iroTES ;r Appl cable Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER R AUTHO ED AGENT: Signature: Date: -54 Oklg 4 yWi Print Name: Kelvin Battle D ay Telephone: 425- 251 -0356 Mailing Address: 25500 74th Ave S Kent city WA 98032 State Zip Date Application Accepted: tin -(S ll Date Application Expires: (S-U- Staff Initials: Q. \Applications\Forms- Applications On Line 3 -2006 - Permit Application.doc Revised: 9 -2006 bh Page 6 of 6 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.TukwilaWA.gov RECEIPT Parcel No.: 9202470010 Permit Number: M11 -130 Address: 1003 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 09/15/2011 Applicant: ICING Issue Date: Receipt No.: R11 -02024 Payment Amount: $391.81 Initials: WER Payment Date: 09/15/2011 12:06 PM User ID: 1655 Balance: $0.00 Payee: KELVIN BATTLE TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd MC Authorization No. 640010 ACCOUNT ITEM LIST: Description 391.81 Account Code Current Pmts MECHANICAL - NONRES PLAN CHECK - NONRES 000.322.102.00.00 313.45 000.345.830 78.36 Total: $391.81 doc: Receiot -06 Printed: 09 -15 -2011 INSPECTION RECORD Retain a copy with permit • INSPECTION NO. PERMIT NO. • CITY OF TUKWILA BUILDING DIVISION 6300 Southcehter Blvd.., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 mil -'30 Project :. .T- ice /.. Type of Inspection: 0r-/ A/4 L : 0) /? Li) I s /i► - sX1 _. tic 1-,P4 tia //407/i4r,"...1 ../ Ada.....? /111 d it .? Address: I 003 ,h1 4 /I Date Called: ,,,edve.. - 71PF. f 4i /4•fl5,4v- 44irJV'C Special Instructions: • • . Date Wanted:. AO /Oh/ .':::; tj�r "y�_i J-/�/� I % J' _ .?/0t _.Z. ,„t,(491ro+�.� — " •R/" /A/1 , en' p.m. Requester: !Ie) . irk," e.---, -I, / +6- 1 -61D #20 7/4/ 6 Phone No: D4.- 6,-(5 76 / proved per applicable codes. DCorrections required prior to approval. COMMENTSs_ D e. O : 0) /? Li) I s /i► - sX1 _. tic 1-,P4 tia //407/i4r,"...1 ../ Ada.....? /111 d it .? v ,,,edve.. - 71PF. f 4i /4•fl5,4v- 44irJV'C .':::; tj�r "y�_i J-/�/� I % J' _ .?/0t _.Z. ,„t,(491ro+�.� — " •R/" /A/1 , !Ie) . irk," e.---, -I, / +6- 1 -61D #20 7/4/ 6 ` P/rSS$f ✓C► v,--7./ i /3,2 04; ,0 / -4'- 4-7 Ai- • • Inspecto Date: / /,, • /b /Q / // I /', NSPECTION FEE R QUIRED4rior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. 2009 Washington State Energy Code Compliance Forms for Nonresidential.and Multifamily Residential ;Mechanical Summary MECH -SUM 09 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised December 2010 Project Info FILE CO rro -,R� ^" ' Project Address I0 3 �j0V. -.i hc,,.n is � irk. i i Date 9 /27 11 I'J' For Build ing ept. Use Applicant Name: KG I v;,-. 3c.:1 -1 le_ Applicant Address: 25 O -34 c c; ' Applicant Phone: 42,s -ZS —0356 Project Description Briefly describe mechanical system type and features. ❑ Includes Plans Include documentation requiring compliance with commissioning requirements, Section 1416. Compliance Option Simple System 0 Complex System 0 Systems Analysis (See Decision Flowchart (over) for qualifications. Use separate MECH -SUM for simple & complex Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. Cooling Equipment Schedule Equip. ID Equip Type Brand Name' Model No.' Capacity2 Btu /h OSA CFM or Econo? SEER or EER IPLV3 Econmizer Option or Exception' Heat Recovery Y/N C41.-- I N P T rc.rr 4rIv R 50 4if 9_ �— (.s J-4,- N/4 TG.R. i� / ' 4 AN-1 +!P rre,nr. G AMs4OC9AN1 /I 26,5 // /, ,.,pile.., 6 // - Heating Equipment Schedule Equip. ID Equip Type Brand Name' Model No.' Capacity2 Btu /h OSA cfm or Econo? _ Heat Recovery Y/N i nputil tV, CODF ®� ul[�t COMP] lA jeffici CE ncy4 PROVED OLE 0 4 2011 - City Of Tuk�•i�! P1 Hi i�lj f� \I�cprm Fan Equipment Schedule Equip. ID Equip Type Brand Name' Model No.' CFM Sp' HP /BHP Flow Controls Location of Service 'If available. 2 As tested according to Table 14 -1A through 14 -1G. 3 If required. ° COP, HSPF, Combustion Efficiency, or AFUE, as applicable. s Flow control types: variable air volume(VAV), constant volume (CV), or variable speed (VS). 6 Exception number from Section INCOMPLETE M11lv 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Mechanical Summary (back) MECH -SUM 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised December 2010 System Description See Section 1421 for full description of p Simple System qualifications. All Systems: ❑ No humidification? ❑ No Reheat? If Heating /Cooling or Cooling Only: ❑ Constant vol? n Split system? I <84000 Btuh ?.7 Economizer � included?,,1 ❑ Air r:�nlPri? ❑ Parkanari cvc? ❑< =135 MO Rtiih? ❑ Coolina Coo < =15 Btuh /ft2? ❑ Heating Cap. > 0 & < =10 Btuh/ft2? If Heating Only: ❑ <1 ono rim? ❑<30% outside air? f Heating Cap. < =10 Btuh /ft2? Decision Flowchart Use this flowchart to determine if project qualifies for Simple System Option. If not, either the Complex System or Systems Analysis Options must be used. ( START Yes Humi or R ification heat? Syste Heating /Cooling • ablin my Heating Only Yes Yes Reference Section 1421 Yes Simple System Allow" (section 1420) Use Complex Systems (section 1430) Complex Systems Refer to MECH -COMP Mechanical Complex Systems for assistance in determining which Complex Systems requirements are applicable to this project. 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential echanical Permit Plans Checklist MECH -CHK 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised December 2010 Project Address Date The following information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Applicability l (yes, no, na) Code I Section Component Information Required I Location 1 on Plans l I Building Department Notes _ HVAC REQUIREMENTS (Sections 1401 -1424) 6 1411 Equipment Performance 1411.1 Minimum efficiency Equipment schedule with type, capacity, efficiency /t.(1 4 1411.1 Combustion htg. Indicate intermittent ignition, flue/draft damper &jacket loss 1 � 1411.1 Air - cooled chiller Provide total air and water chiller capacity NA 1411.2.1 Water - cooled chiller Full -load and NPLV values adjusted for any non - standard conditions OA 1411.4 Pkg. elec. htg.& clg. List heat pumps on schedule , N A 1411.5 Unenclosed Heat Indicate radiant heat system and occupancy controls 1412 HVAC Controls y1412.1 Temperature zones Indicate locations on plans '-t' 1412.2 Deadband control Indicate 5 degree deadband minimum IU>� 1412.3 Humidity control Indicate humidistat JA 1412.4 Setback and Shutoff Indicate thermostat with 7 day program capability & required setback 1412.4.1 Dampers Indicate damper location, leakage rate, control type, & max. leakage -3 A 1412.4.2 Optimum Start Indicate optimum start controls 1412.5 Heat pump control Indicate heat pump thermostant & outdoor lockout on schedule IJA 1412.6 Combustion heating Indicate modulating or staged control 7� 1412.7 Balancing Indicate balancing features on plans 1412.8 Ventilation Control Indicate demand control ventilation for high- occupancy areas ��;� 1412 9 Loading Dock & Garage Ventilation Indicate enclosed loading dock & parking garage ventilation system activation and control method. OA 1422 Thermostat interlock Indicate thermostat interlock on plans NA 1432.2.1 Temperature Reset Indicate temperature reset method 1413 Air / Water Economizers k),\ 1412.1 Single zone systems Indicate multiple cooling stage control capability. 1413.1 Air Econo Operation Indicate 100% capability on schedule 1413.1 Wtr Econo Operation Indicate 100% capacity at 45 degF db & 40 deg F wb 1413.2 Wtr Econo Document Indicate max. OSA condition for design clg load & equipment performance data. 1413.3 Integrated operation Indicate capability for partial cooling 1413.4 Humidification Indicate direct evap or fog atomization w/ air economizer 1414 Ducting Systems 1414.1 Duct sealing Indicate duct design pressures, sealing, and testing requirements Pik 1414.1.2 Low press. duct test Indicate applicable low pressure duct systems shall be leak tested 1414.1.3 High press. duct test Indicate high pressure duct systems shall be leak tested, and identify the location of this ductwork on plans ik1 1414.2 Duct insulation Indicate R -value of insulation on duct 1415 Piping Systems '/ 1415.1 Piping insulation Indicate R -value of insulation on piping ( 1416 Completion Requirements IV- 1416.3.2 System Balancing Indicate air and water system balancing requirements 1416.3.3 Functional Testing Provide sequence of operations and test procedures. 1416.3.4 Documentation Indicate O &M manuals, record drawings, staff training 1416.3.5 Comm. Report Indicate requirements for final commissioning report 1416.4 Compliance Chklist Submit to building official upon substantial completion. Mechanical Summary Form Completed and attached. Equipment schedule with types, input/output, efficiency, cfm, hp, economizer 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multitamily Residential Me• chanical Permit Plans Checklist Continued MECH -CHK 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised December 2010 Project Address 'Date The following information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Applicability I Code (yes, no, na) Section ` 1 Location JComponent jInformation Required on Plans Building Department Notes SERVICE WATER HEATING AND HEATED POOLS (Sections 1440 -1454) 1440 Service water htg. 1441 Elec. water heater Indicate R -10 insulation under tank 1442 Shut -off controls Indicate automatic shut -off of circulators or heat trace 1443 Pipe Insulation Indicate R -value of insulation on piping 1444 Pump Energy Indicate method of pump energy management (Sec 1438) 1445 Heat Recovery Indicate preheat capacity as % of peak service water demand. 1460 Heated Pools 1452 Heat Pump COP Indicate minimum COP of 4.0 1452 Heater Efficiency Indicate pool heater efficiency 1453 Pool heater controls Indicate switch and 65 degree control 1454 Pool covers Indicate vapor retardant cover 1454 Pools 90+ degrees Indicate R -12 pool cover 1455 Heat Recovery Indicate method and capacity of exhaust air temperature reduction COLD STORAGE (Sections 1460 -1465) • 1460 Cold Storage 1463 Evaporators Indicate motor type and speed control 1464 Condensors Indicate condenser cooling type, design wb temp and control 1465 Compressors Indicate design minimum condensing temp and control. If "no" is indicated for any item in Sections 1401 -1424 or 1440 -1465 , provide explanation: C- ER IFIEDM www.ahridirector,y:org Certificate of This combination qualifies for a Federal Energy Efficiency Tax Credit when placed in service between Feb 17, 2009 and Dec 31, 2011. ro _ ct Ratin.s AHRI Certified Reference Number: 4151217 Date: 9/14/2011 Product: Split System: Heat Pump with Remote Outdoor Unit- Air -Swirce Outdoor Unit Model Number: 4TWR5049E1 Indoor Unit Model Number: GAM5A0C48M41 Manufacturer: TRANE Trade /Brand name: XR15 WEATHERTRON Manufacturer responsible for the rating of this system combination is TRANE Rated as follows in accordance with AHRI Standard 210/240 -2008 for Unitary Air - Conditioning and Air - Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI- sponsored, independent, third party testing: Cooling Capacity (Btuh): EER Rating (Cooling): SEER Rating (Cooling): Heating Capacity(Btuh) @ 47 F: Region IV HSPF Rating (Heating): Heating Capacity(Btuh) @ 17 F: 48000 12.50 15.50 47000 8.50 30600 INC®UPLETE REVIEWED FOR CODE COMPLIANCE APPROVED OCT 0 4 2011 City of Tukwila PUILDING DIVISION Ratings followed by an asterisk (') indicate a voluntary rerate of previously published data, unless accompanied with a WAS, which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on thls Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI. This Certificate shall only be used for individual, personal and confidential reference purposes. The contents of this Certificate may not, In whole or in part, be reproduced; copied; disseminated; entered Into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's individual, personal and confidential reference. CERTIFICATE VERIFICATION The information for the model cited on this certificate can be verified at www.ahridirectory.org, click on "Verify Certificate" link and enter the AHRI Certified Reference Number and the date on which the certificate was Issued, which is listed above, and the Certificate No., which is listed below. ©2011 Air - Conditioning, Heating, and Refrigeration Institute ka [az Air- Conditioning, Heating, Del Via and Refrigeration Institute CERTIFICATE NO.: 129605096183867674 TWA" TAG: NED 6:dK lm" °er lions are in mm/inches. . REVIEW CODE COMPLIANCE APPROVED OCT 0 4 2011 stoma 51811 City On`�oO1tf"' iilii ". FUILDINC� TOP 01 US11. 80 1[ fAD o l�L1a0 i0 1t 110.011 LOTS 01:48 I001 5005 018101(1 11 05 1 AO 0 or 02 Al LEAST ms 112'1 IWl 4II YD ut 5110010//1 1/21141/ m TVO 1104. 01008 110 00510 051(1r81CTt0. IL(CIIICAL 1t11O1n 22.2 0 (1111 01*. 81E IA 41111. 28.4 11.1111 011. 1.0. 1202 1((2222 1 11' e02 error 105 010CUICAL 581011 2805(0 4[[101'1ppu�[ [1 ltlrlt {.YUVI. CO21101101111111 1/1.14 ttV0 55111050 IV 1117160. M.O. r05 ALTt1117(1 1ST CAL 211106 1008 114 r0811 Ull ttii�i0i 51. 11/2 1.1. «0802 14211 1111 10.510 52182050 1A1 1127182. 101115 ABB 1E8na WALK I. 1.0. ACM( o4tt6 121101101 1110 1I4• 1AL 54120 58410011 745 1111210. 0881 Enna VALVE. •0' I.O. 509124 04120 C01810101 TITS 1/1' 1U 2101 5811010E IV 111110. From Dwg. 0156010 8A68 A 8 C 0 F 0 K 47wRe04 0 4 1147 1161a) 945 807.1/4)_ 670 (34114) 7s 1010 160(8) 88 0.74) 219 (642) 88 05.10) 805 (20) 4111 r POhas+.0 LE wOpy P. 4TWR5049E- SUB - 100.01 SUBMITTAL 4 Ton Split System Heat Pump -1 Phase 4TWR5049E Product Specifications OUTDOOR UNIT 00 POWER CONNS. - V/PHIHZ O MIN. BRCH. CIR. AMPACITY BR. CIR. PROT. RTG. - MAX. (AMPS) 4TWR5049E1000A 20W230/1/60 30 50 COMPRESSOR NO. USED - NO. SPEEDS VOLTS/PH/HZ R.L. AMPS 0 - LR. AMPS FACTORY INSTALLED START COMPONENTS O INSULATION/SOUND BLANKET COMPRESSOR HEAT CUMAIUFP 1 -1 208/23W1/60 21.8 -117 NO NO YES OUTDOOR FAN DIA. (IN.) - NO. USED TYPE DRIVE - NO. SPEEDS CFM 0 0.0 IN. W.G. NO. MOTORS - HP MOTOR SPEED R.P.M. VOLTS/PH/HZ EL AMPS OUTDOOR COIL -TYPE ROWS - F.P.I. FACE AREA (SO. FE) TUBE SIZE (IN.) REFRIGERANT LBS. - R -410A (0.D. UNIT) FACTORY SUPPUED UNE SIZE - IN. O.D. GAS UNE SIZE - IN. O.D. UQ. PROPELLER. 27.6 -1 DIRECT -1 4240 1 -1/3 850 20W230/1160 2.80 SPINE FINTM 2 -24 29.15 3/8 13 LBS., 10 OZ. YES 7/8 3/8 CHARGING SPECIRCATION SUBCOOLING 8 °F DIMENSIONS CRATED (IN.) WEIGHT SHIPPING (LBS.) NET (LBS.) H X W X D 51 x 35.1 x 38.7 331 294 0 toddled h accordance orb the AS-Source Unary Aloccaffiloner Equkrt1W o81 ft16 n pmgrtun, ntzId1 to hated on ARl ealdard 216240. 0 Rated In ascordarre nth ARI atenderd 270. �?+ CdtldeadIn accents= ed111NalElseCodes. Use atyHACRd2oWa- kenahaas. 0 Sworn/ Ns -Dry Col -ONdoor Thlo tube approdortn For we 1 80 0. Maa Vt. Mullea OD1141tr 91 -Wad le 2. For gredar onathconsultref geradppap software Pub. tin 22431281 r denotes bast reread. Cr This value shown tor compressor RLA on the tat lusetelate and an 6Ns 1pwBcadon died b used to compute dawn emelt draitarpeollyeral met luse tisa ewbesh05abOnaa1d1Bradtadeabrl Dann. rJ No em o mnpaser 19s means gddc dart 12 mmpalena. PTC mean po n rampart A weighted Sound Power Level [dB (A MODEL SOUND POWER LEVEL NINA)] A- WEIGHTED FULL OCTAVE SOUND POWER LEVEL dB - [dB(A)] High Stage 63 125 250 500 1000 2000 4000 8000 4TWR5049E W 75 43.7 I 51.2 , 54.5 _I 61 I 61.5 I_ 57.1 I 51.3 I 40.7 1 ore: Kates in accoroance With AHKI Standard 270 -2008. 2010 Ttane MLI (3d RECEIVED SEP 15 2011 PERMIT CENTER Mechanical Specification Options General The 4TWR5 is fully charged from the factory for up to 15 feet of piping. This unit is designed to operate at outdoor ambient temperatures as high as 115 °F. Cooling capacities are matched with a wide selection of air handlers and fur- nace coils that are A.R.I. certified. The unit is certified to UL 1995. Exterior is designed for outdoor application. Casing Unit casing is constructed of heavy gauge, G90 galvanized steel and painted with a weather - resistant powder paint on all louvers, panels, prepaint on all other panels. Corrosion and weather- proof CMBP -G30 DuraTuffm base. Refrigerant Controls Refrigeration system controls include condenser fan and compressor contac- tor. High and low pressure controls are inherent to the compressor. A factory installed liquid line drier is standard. Compressor The Climatuffa compressor features intemal over temperature and pressure protection and total dipped hermetic motor. Other features include: roto lock suction and discharge refrigerant con- nections, centrifugal oil pump and low vibration and noise. AM Standard 210/240 UHP 4TUS Condenser Coll The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by louvered panels. Low Ambient Cooling As manufactured, this unit has a cool- ing capability to 55 °F. The addition of an evaporator defrost control with TXV permits low ambient cooling to 20° F. Accessories Thermostats — Cooling only and heat/ cooling (manual and automatic change- over). Sub -base to match thermostat and locking thermostat cover. 08110 Thane has a policy of continuous product and product data Improvement and it reserves the right to Mang. han ee design and spetifcatfons without notice. Submittal TAG: 4 Ton Convertible Air Handler GAM5A0C48M41 SA I. 50 21.75 1.50 14.35 1.50 m 2011 TFane 3.11 GAS LINE SEE TABLE GAM5A0C48- .SUB -1 B 3.00 IOUID LINE SEE TABLE I.500 D MINIMUM UNIT CLEARANCE TABLE TO COMBUSTIBLE MATERIAL (REOUIRED) SERVICE CLEARANCE (RECOMMENDE0I SIDES FRONT BACK INLET DUCT OUTLET DUCT 0' 0• 0' 0' 0' 2' 21' 0' MODEL NO. A B C D E F H Flow Control GAM5A0C48 61.7 23.5 20.5 51.5 20.5 10.3 24.9 TXV/NB R-410A Gas Line BRAZE 7/8 R-410A Uq. Une BRAZE 3/8 PRODUCT SQECIFICATIONS PRODUCT SPECIFICATIONS GAM5AOC48M41 Sf 208 - 230/1/60 See O.D. Specffications Plate Fin 4 -14 5.96 3/8 EEV 3/4 NPT See Outline Drawing Centrifugal 11 X 10 Direct - 5 See Fan Performance Table 1 -3/4 1050 208 - 230/1/60 6.0 MODEL RATED VOLTS/PH/HZ. RATINGS 0 INDOOR COIL —Type Rows -- F.P.I. Face Area (sq. ft.) Tube Size (in.) Refrigerant Control Drain Conn. Size (in.) 0 DUCT CONNECTIONS INDOOR FAN —Type Diameter -Width (In.) No. Used Drive - No. Speeds CFM vs. In. w.g. No. Motors — H.P. Motor Speed R.P.M. Volts/Ph/Hz F L Amps FILTER Filter Furnished? Type Recommended No.-Size-Thickness REFRIGERANT Ref. line Connections Coupling or Conn. Size — in. Gas Coupling or Conn. Size — In. Uq. DIMENSIONS Crated (In.) Uncrated WEIGHT Shipping (Lbs.) /Net (Lbs.) No Throwaway 1 - 22X20 -1 in. RA10A Brazed 7/8 3/8 HxWxD 63-1/4 x 27 -1/2 x 25-3/4 61-3/4 x 23-1/2 x 21-3/4 176/166 O These Air Handlers are A.H.R.I. certified with various Split System Air Condi- tioners and Heat Pumps (AHRI STANDARD 210/240). Refer to the Spilt Sys- tem Outdoor Unit Product Data Guides for perbnnance data. O 9/4' Male Plastic Pipe (Ref.: ASTM 1785-76) GAM5AOC48M41 SAA MINIMUM HEATER AIRFLOW CFM . Heater Minimum Air Speed Tap With HP Without HP BAYEAACO5BKIAA BAYEAACO5LG1AA Tap 3 Tap 2 BAYEAACO8BK1AA BAYEAACO8LGIAA Tap 3 Tap 2 BAYEAACI OBK1 AA BAYEAAC1OLG1AA Tap 3 Tap 2 BAYEABC15BK1AA Tap 4 Tap 3 BAYEABC2OBK1AA Tap 4 Tap 3 BAYEACC25BK1AA Tap 5 Tap 4 SEE AIR HANDLER NAMEPLATE OR PRODUCT DATA FOR EXCEPTIONS US AIRFLOW PERFORMANCE GAM5A0C48M41SAA EXTERNAL STATIC (In. w g.) AIRFLOW (CFM) 240 VOLT Speed Taps - 230 VOLTS Speed Taps - 208 VOLTS Am 5 4 3 2 1 5 4 3 2 _ 1 0 1913 _ 1770 1694 1593 866 1910 1767 1691 1590 863 0.1 1874 1730 1653 1547 791 1868 1724 1647 1541 785 0.2 1834 1690 1611 1505 699 1825 1681 1602 1496 690 0.3 1791 1646 1567 1456 620 1780 1635 1556 1445 609 0.4 1748 1600 1521 1410 537 1734 1586 1506 1396 522 0.5 1708 1556 1476 1367 _ 453 1691 1539 1459 1350 437 0.6 1668 1516 1436 1326 370 1648 1496 1416 1306 351 0.7 1629 1475 1394 1283 - 1607 1452 1372 1260 - 0.8 1588 1435 1352 1236 - 1563 1410 1327 1211 - 0.9 1541 1390 1304 1183 - _ 1513 1362 1276 1156 - NOTES: 1. Values are with wet coil and without filters. 2. Contact your particular filter manufacturer for pressure drop data. 3. Electric heater pressure drop Is negligible and is included within the airflow data. 4. Tap 1 is a continuous fan speed tap. WIRING DATA GAM5A0C48M41SAA Heater Model No. No. of Circuits 240 VOLT 208 VOLT Capacity Am Minimum Circuift Ampa�Y Maximum Overload Protection Capacity Heater " Per Clrouft Minimum Circuit �Pa�Y Maximum Overload Protection kW BTUH Per d It BTUH No Heater - - - 6.0' 8 15 - - 6.0' 8 15 BAYEAAC05++ 1 4.80 16400 20.0 33 35 3.60 12300 17.3 29 30 BAYEAAC08++ 1 7.68 26200 32.0 48 50 5.76 19700 27.7 42 45 BAYEAAC10++ 1 9.60 32800 40.0 58 60 7.20 24600 34.8 51 60 circuit 1 9.60 49200 40.0 58 60 7.20 36900 34.6 51 60 BAYEABCI5++ circuit 2 4.80 49200 20.0 25 25 3.60 36900 17.3 22 25 circuit 1 9.60 65800 40.0 58 60 7.20 49200 34.6 51 60 BAYEABC2044 circuit 2 9.60 65600 40.0 50 50 7.20 49200 34.6 43 45 circuit 1 9.60 82000 40.0 58 60 7.20 61500 34.6 51 60 BAYEABC25++ circuit 2 9.60 82000 40.0 50 50 7.20 61500 34.6 43 45 circuit 3 4.80 82000 _ 20.0 25 25 3.60 _ 61500 17.3 22 25 Note:' Motor Amps Notes: 1. See Product Data or Air Handler nameplate for approved combinations of Air Handlers and Heaters 2. Heater model numbers may have additional suffix digits. v. Mechanical Specifications • Air-Tito 11T"' cabinet — 2% or less air leakage — Precision applied - durable door seals — Specially designed air seal around refrigerant, condensate and conduit connections — Double wall foamed cabinet system — >— R-4.2 insulating value — No loose fiber design — Smooth cleanable interior design — Sweat eliminating design — Composite foamed cabinet doors — Water proof cabinet design — Integrated horizontal drain pans — Modular cabinet with 5/16" alien wrench "quick latch" design • Multi- position up /down flow horizontal left/right • Side return option • Control board protection pocket built into cabinet wall • Alert port to view control board codes without door removal • 10 alert codes • Low voltage terminal connection point • Quarter turn phillips head door fasteners • Vortica® blower with polarized plug connections and integrated slide deck for easy removal Trans 6200 Top Highway Tyler, 7X 75707 • Aluminum coil with integrated slide deck for easy removal and polarized plug connections on coil EEV • Patented enhanced coil fin • Electronic Expansion Valve (EEV) with low ambi- ent and low superheat compressor protection • Dual refrigerant compatible as shipped • Slide in electric heaters with polarized plug connections (sold as accessory) • UVC Tight kit with safety switch and polarized plug connections (sold as accessory) • Labeled panels and connections • Molded in l" standard filter rail • High efficiency ECM motor • Soft start fan motor operation • Built in fan delay modes • Maximum width of 23.5" • Compact 20.8" depth with doors removed • Two tone color • Fused 24v power • Safety door switch • 1 -year warranty • 10 -year warranty registered • Optional extended warranty available The manufacturer has a policy of continuous product and product data Improve- ment and It reserves the right to change design and specification without notice. • Tukwila Building Division Dave Larson, Senior Plan Examiner Determination of Completeness Memo Date: September 20, 2011 Project Name: Icing Permit #: M11 -130 Plan Review: Dave Larson, Senior Plans Examiner The Building Division has deemed the subject permit application incomplete. To assist the applicant in expediting the Department plan review process, please forward the following comments. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not 'copied.) 1. Please complete a WA State Energy Code Mechanical Summary Form. I have included a copy with this incomplete memo. Please find attached 2. Provision for an economizer was not shown on the plan. This is a replacement to a existing unit. We are using W.S.E.0 table 11 -1, option B 3. Provision for fresh air was not shown on the plan however per a site visit, the system appears to be connected to the mall fresh air duct. The requirement for fresh air per the occupancy will need to be calculated per the WSEC and shown on the plan for balancing purposes and documentation at commissioning. Existing fresh air duct shown on drawing and calculation also shown on drawing. 4. Per section 307.2.3 of the IMC, an auxiliary or secondary condensate drain system is required for the air handler per one of the four options listed in this section. Please show the chosen option on the plans. We are using option 4. noted on drawings. Should there be questions concerning the above requirements, contact the Building Division at 206 -431- 3670. No further comments at this time. • City of Tukwila • Jim Haggerton, Mayor Department of Community Development Jack Pace, Director September 20, 2011 Kelvin Battle Performance Heating & Air Conditioning 25500 74 Av S Kent, WA 98032 RE: Incomplete Letter #1 Mechanical Permit Application M11 -130 Icing —1003 Southcenter Mall Dear Mr. Battle, This letter is to inform you that your permit application received at the City of Tukwila Permit Center on September 15, 2011 is determined to be incomplete. Before your application can continue the plan review process the attached/following items from the following department(s) need(s) to be addressed: Building Department: Dave Larson at 206 431 -3678 if you have any questions concerning the attached comments. Please address the comment above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at the Permit Center at (206) 431 -3670. Sincerely, Bill Rambo Permit Technician Enclosures File: MI1 -130 W:\Permit Center\Incomplete Letters\2011 \M11-130 Incomplete Ltr # 1.doc 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 Tukwila Building Division Dave Larson, Senior Plan Examiner Determination of Completeness Memo Date: September 20, 2011 Project Name: Icing Permit #: M11 -130 Plan Review: Dave Larson, Senior Plans Examiner The Building Division has deemed the subject permit application incomplete. To assist the applicant in expediting the Department plan review process, please forward the following comments. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. Please complete a WA State Energy Code Mechanical Summary Form. I have included a copy with this incomplete memo. 2. Provision for an economizer was not shown on the plan. 3. Provision for fresh air was not shown on the plan however per a site visit, the system appears to be connected to the mall fresh air duct. The requirement for fresh air per the occupancy will need to be calculated per the WSEC and shown on the plan for balancing purposes and documentation at commissioning. 4. Per section 307.2.3 of the IMC, an auxiliary or secondary condensate drain system is required for the air handler per one of the four options listed in this section. Please show the chosen option on the plans. Should there be questions concerning the above requirements, contact the Building Division at 206 -431- 3670. No further comments at this time. HERMIT COORD PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M11 -130_ PROJECT NAME: ICING DATE: 09/28/11 SITE ADDRESS: 1003 SOUTHCENTER MALL Original Plan Submittal X Response to Incomplete Letter # 1 Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: �I B�Il� ling teflon f, Public Works Fire Prevention Structural Planning Division ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete M Incomplete DUE DATE: 09 /29/11 Not Applicable Comments: Permit, Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route 11C Structural Review Required No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 10/27/11 Approved n Approved with Conditions Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center' Use Only. CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M11 -130 DATE: 09 -15 -11 PROJECT NAME: ICING SITE ADDRESS: 1003 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: Building Division Public Works A /4- a� � I ire Prevention S Structural Planning Division ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete DUE DATE: 09-20-11 Not Applicable Comments: Permit Center Lite Only ((]] - INCOMPLETE LETTER MAILED: "V` 2-6-11 LETTER OF COMPLETENESS 111 D: Departments determined incomplete: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: ""rte TUES /THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: ❑ No further Review Required DATE: n APPROVALS OR CORRECTIONS: Approved Notation: Approved with Conditions DUE DATE: 10 -18 -11 Not Approved (attach comments) n REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.citukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: Plan Check/Permit Number: M1 1-13 0 ® Response to Incomplete Letter # 1 ❑ Response to Correction Letter # ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Icing Project Address: 1003 Southcenter Mall Contact Person: k IVl- -&-f) It Phone Number: 4 ZS -Zs1 - fw56 Summary of Revision: P�tr,.�L Sex- �.4-h c. 4 e ��V P7crlYIl'ela t&K of Ccrn fie I eihcS,S ine.rna l l Sheet Number(s): ''(Y) I hc..s rcvislz,-, dG S_ "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: XEntered in Permits Plus on \applications \forms- applications on line\revision submittal Created: 8 -13 -2004 Revised: Contractors or Tradespeople1nter Friendly Page • General /Specialty Contractor A business registered as a construction contractor with Lftl to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name PERFORMANCE HEATING Et A/C INC UBI No. 600601386 Phone 4252510356 Status Active Address 25500 74Th Ave S License No. PERFOHA15ORT Suite /Apt. License Type Construction Contractor City Kent Effective Date 12/30/1985 State WA Expiration Date 4/30/2013 Zip 98032 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Business Owner Information Name Role Effective Date Expiration Date MILLER, DANIEL E President 11/27/2007 Bond Amount ERDAHL, DARRIN Vice President 11/27/2007 748802C GOWIN, RICHARD L Vice President 01/01/1980 04/26 /2011 GOWIN, CONSTANCE F Vice President 01/01/1980 11/15/2007 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 10 DEVELOPERS SURETY & INDEM CO 748802C 10/01/2007 Until Cancelled $12,000.00 11/27/2007 9 DEVELOPERS SURETY Ft INDEM CO 853803C 04/28/2002 Until Cancelled 12/24/2007 $12,000.0004/23 /2002 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 20 Ohio Cas Ins Co BKA54440798 04/28/2011 04/28/2012 $1,000,000.0004 /26/2011 19 co 10 CAS INS BKA54440798 04/28/2010 04/28/2011 $1,000,000.0004 /27/2010 18 OOHIO CAS INS BK0085362185704/28/2007 04/28/2010 $1,000,000.00 04/22/2009 17 BURLINGTON INS CO HGL0012730 04/28/2006 04/28/2008 $1,000,000.0004 /24/2007 16 BURLINGTON INS CO HGL00006025 04/28/2005 04/28/2006 $1,000,000.0004 /27/2005 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https://fortress.wa.gov/lni/bbip/Print.aspx 10/05/2011 100 0 AF- 00 00 00 0 0 AH11 n 14x16 14x16 300 200 1600 8x16 10 "0 200 0 00 0 0 N I 00 00 0 0 0 0 AH -1 CONNECT TO EXISTING DUCT WORK. g & REFRIGERANT SET LINES UP TO ROOF TO CU -1 EXISTING DUCTING WORK BY OTHER. RETAIL SPACE HVAC PLAN 1/4" = 1=0" VICINITY MAP SCOPE OF WORK INSTALL (1) SPOT SYSTEMS HEATPUMP TO SERVE NEW TENANT. INDOOR UNIT AH -1 TO BE CONNECTED TO EXISTING DUCTING. OUTDOOR UNIT CU -1 TO BE PLACED ON ROOF WITH LINE SET CONNECTED TO AH -1. INSTALL (1) 7 —DAY PROGRAMMABLE THERMOSTAT. INSTALL CONDENSATE PIPING AND PUMPS FOR THE AIR HANDLERS TO TERMINATION AT THE ROOF. REFRIGERATION AND LOW VOLTAGE UNDER SEPARATE PERMITS. CODE NOTES: (PER W.S.E.C. W/ SEATTLE AMENDMENTS) 1) SEAL DUCTS PER W.S.E.C. SECTION 1414.1. 2) PROVIDE PIPE INSULATION PER W.S.E.C. TABLE 14 -6. 3) SYSTEMS CU-1/AH-1 TO BE EXEMPT FROM ECONOMIZER REQUIREMENTS PER W.S.E.C. TABLE 11 -1, OPTION B. 4) THERMOSTAT TO COMPLY W/ SECTION 1412 OF W.S.E.C. 9.26.11 FASTEN CU -1 TO ROOF SLEEPERS W/ 18 —GA. ANGLE. SCREW STRAP TO ROOF SLEEPERS & UNIT BASE RAIL. TWO STRAPS EACH END (4) TOTAL. 0 1 0 0 PER SECTION 307.2.3 OF THE IMC. WE ARE USING OPTION 4 BY PROVIDING A SWITCH IN THE PRIMARY DRAIN PAN THAT WOULD SHUT OFF THE SYSTEM IF THE DRAIN PAN IS BLOCKED. REVISIONS No changes shalt be made to the scope of work without prior approvvt of Tukwila Building Division. NOTE: Revisions will require a new plan sulnitt^.I and may include additional plan review fees. 4 "X6 "X4' (2) (EXISTING) EXISTING SLEEPERS FASTEN AND ROOFED IN. ATTACHMENT DETAIL CU -1 NTS _.. APPR City ©f u wiia n JILDING IVISION REVIEWED FOR CODE COMPLIANCE APPROVED OCT 04 2011 WESTFIELD MALL SPACE 432 SEPARATE PERMIT REQUIRED FOR: 0 Niethanicai Electrical Plumbing Gas Piping City of Tukwila BUILDING DIVISION NEW i" LIQUID & i" SUCTION IN CEILING SPACE BELOW. ROUTE FROM AH -1 & UP THRU ROOF TO CU -1 ON EXISTING PLATFORM. PARTIAL ROOF PLAN 1116" =1-0" SPLIT SYSTEM AIR -TO -AIR HEAT PUMP SCHEDULE TAG MFR DESCRIPTION MODEL TONS INDOOR FAN CAPACITY -BTUH SEER HSPF AHR/ CERT /F /EDREFERENCE # REFR /G, PIPE ELECTRICAL MOCP SOUND dB(A) WEIGHT (LBS.) MIN OSA SETTING LOCATION CFM ESP HP HEATING COOLING LIQUID GAS VOLTS PH MCA CU -1 TRANE HEATPUMP OUTDOOR UNIT 4TWR5049E 4 — — 1/2 47,000 48,000 15.50 8.5 4151217 3/8" 7/8" 208 10 30 50 73 294 — ROOFTOP AH -1 TRANE HEATPUMP AIR HANDLER GAM5AOC48M41 SA — 1600 0.60" — N \A SEE CU -1 SEE CU -1 SEE CU -1 4151217 3/8" 7/8" 208 10 — — — 166 265* RETAIL SPACE 9.26.11 /2\ SPLIT SYSTEM IN COMPLIANCE WITH WASHINGTON STATE ENERGY CODE TABLE 11 -1, OPTION B (10% GREATER SEER RATING THAN THAT REQUIRED IN TABLE 14 -1B) AS A REPLACEMENT TO AN EXISTING SYSTEM OF THE SAME CAPACITY. *PER ASHRAE STANDARD 62. 9.26.110 Vbz =RP Z 0 P+R*AZ 263cfm= 7.5 *17 +.12 *1133 FILE COPY wit No. M\t •9)0 Plan review approval Is subject to errors and omissions. Approval of construction documents does not authcr : ;s k violation of any adopted code or ordinance. Recdcpt of approved pig Copy and conditions is acimowledgpd: By.,A 1 •4'14 _ . Date: //9, City Of "I'takwila BUILDING DIVISION 1 & IMC REQUIREMENTS cirr�i�ruKKn SEP 2 8 2011 1 n PERMITCEN'fER J;; � INCOMPLETE L1'R# 1 .. Dynamic Solutions for the Built Enviroment co 0 cn oWC z 0 N 06 z O H co ELEVATION a z 0 Westfield South Center Icing 2800 South Center Ma DATE: 9.14.2011 DRAWN: KB ENGR: MS APPVD: JOB NUMBER: M1 SHEET 1 OF 1