Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M11-131 - BOEING #9-53
BOEING #9 -53 9725 EAST MARGINAL wys EXPIRED OS -27 -12 Mi 1 -131 Parcel No.: Address: City oihukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov MECHANICAL PERMIT 0003400018 9725 EAST MARGINAL WY S TUKW Project Name: BOEING #9 -53 Permit Number: M11 -131 Issue Date: 02/29/2012 Permit Expires On: 08/27/2012 Owner: Name: Address: Contact Person: Name: Address: Email: Contractor: Name: BOEING COMPANY THE PROPERTY TAX DEPT , PO BOX 3707 M/C 20 -00 98124 JOHN MURDOCH PO BOX 3707 M/C 89 -14 , SEATTLE WA 98124 JOHN.S.MURDOCH @BOEING.COM Phone: 253 -657 -0868 BOEING COMPANY, THE Phone: 312 544 -2535 Address: 100 N RIVERSIDE, M/C 5003 -4027 , CHICAGO IL 60606 -1596 Contractor License No: BOEINC *294ML Expiration Date: 01/18/2013 DESCRIPTION OF WORK: REMOVE OVERHEAD AIR DIFFUSERS AND FIRE PROTECTION SPRINKLERS IN (2) ROOMS. INSTALL REPLACEMENT DIFFUSERS AND SPRINKLERS IN NEW SUSPENDED CEILINGS. Value of Mechanical: $13,000.00 Type of Fire Protection: UNKNOWN Electrical Service Provided by: Permit Center Authorized Signature: Fees Collected: $342.81 International Mechanical Code Edition: 2009 &9J( Date: d� M LZ I hereby certify that I have read and ex- ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complie, wit , whether specified herein or not. The granting of this permit does not pre me to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the perf•rmance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this •C 't. Signature: Print Nam UNN etweia � NloeAocv Date Re' a l9 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -4/10 M11-131 Printed: 02 -29 -2012 0 • PERMIT CONDITIONS Permit No. M11-131 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431- 3670). 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IMC -4/10 M11-131 Printed: 02 -29 -2012 1150Z CITY OF TUK�LA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.ciov Building Perri . No. b tk,- -S I Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No. Project No.'. k■ l OO (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** 4o SITE LOCATION N ecru& Site Address: 9725 East Marginal Way So Tenant Name: The Boeing Company Property Owners Name: The Boeing Company Mailing Address: P.O. Box M/C 89 -14 King Co Assessor's Tax No.: Suite Number: 9-53 lb Floor: 1 New Tenant: ❑ Yes J .. No Seattle, WA. City 98124 State Zip CONTACT PERSON — who do we contact when your permit is ready to be issued Name: John S. Murdoch Mailing Address: Same as Above Day Telephone: (253) 657 -0868 E -Mail Address: john.s.murdoch @boeing.com City State Fax Number: (253) 657 -0858 Zip GENERALCONTRACTORINFORMATION — (Contiraetor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: The Boeing Company Mailing Address: City Day Telephone: Fax Number: Expiration Date: 01/14/2013 Contact Person: Same as Above E -Mail Address: Contractor Registration Number: BOEINC *294ML State Zip ARCHITECT OF RECORD:- All.plans•must be stamped; by= Architect of Record Company Name: The Boeing Company Mailing Address: Same as Above Contact Person: Thomas Hanson A.I.A. E -Mail Address: thomas.w.hanson @boeing.com City State Zip Day Telephone: (206) 947 -4880 Fax Number: ENGINEER:OF RECORD — All plans must be stamped by Engineer of: Record Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: State Zip H:\ApplieetionsWotms- Applications On Line\2010 Applications \7 -2010 - Permit Application.doc Revised: 7 -2010 bb Page 1 of 6 BUILDING PERMIT INFORMATI - 206 -431 -3670 • Valuation of Project (contractor's bid price): $ X00.00 OB Existing Building Valuation: $ 2,000,000.00 r�! Scope of Work (please provide detailed informa ,or ` lbw suspended Acoustical ceilings in two existing Rooms. Will there be new rack storage? ❑ Yes m.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes m No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: m Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes m No If ' yes ', attach list of materials and storage locations on a separate 8 -1/2 " x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications \Forms- Applications On Line \2010 Applications\7 -2010 - Permit Application.doc Revised: 7 -20 V 0 bh Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction.per IBC Type of Occupancy per IBC l a' Floor 54,821 1,469 II -B Business 2nd Floor 43,080 3`d Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes m No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: m Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes m No If ' yes ', attach list of materials and storage locations on a separate 8 -1/2 " x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications \Forms- Applications On Line \2010 Applications\7 -2010 - Permit Application.doc Revised: 7 -20 V 0 bh Page 2 of 6 MECHANICAL PERMIT INFORMATION — 206 -431 -3670 MECHANICAL CONTRACTOR INFORMATION Company Name: Same As Above Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Mechanical work (contractor's bid price): $ if; Scope of Work (please provide detailed information): Remove overhead Air Diffusers and Fire Protection Sprinklers in (2) Rooms. Install Replacement Diffusers and Sprinklers in New Suspended Ceilings. Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New .... ❑ Replacement .... ❑ Fuel Type: Electric ❑ Gas .... ❑ Other: Indicate type of mechanical work being installed and the quantity below: Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace<100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace> 100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM Incinerator — Comm/Ind H:\Applications \Forms - Applications On Line\2010 Applications \7 -2010 - Permit Application.doc Revised: 7 -2010 bh Page 4 of 6 • • PERMIT APPLICATION NOTES — Applicable to all permits in this application IDate Application Accepted: Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF • Y B THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 Signature: ENT: rite ddgatetri Print Name: dohn S. Murd•ch - The Boeing Company Mailing Address: P.O. Box 3707 M/C 89 -14 Date: 011*Yr 011 Day Telephone: 253- 657 -0868 Seattle WA 98124 City State Zip Date Application Expires: Staff Initials: H: Applications \Forms- Applications On Line12010 Applicationsl7.2010 - Permit Application.doc Revised: 7.2010 bh Page 6 of 6 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206-431-3665 Web site: http: / /www.TukwilaWA.gov RECEIPT Parcel No.: 0003400018 Permit Number: M11 -131 Address: 9725 EAST MARGINAL WY S TUKW Status: PENDING Suite No: Applied Date: 09/21/2011 Applicant: BOEING #9 -53 Issue Date: Receipt No.: R11 -02071 Initials: User ID: Payee: WER 1655 Payment Amount: $342.81 Payment Date: 09/21/2011 02:03 PM Balance: $0.00 JOHN MURDOCH TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd MC Authorization No. 077214 ACCOUNT ITEM LIST: Description 342.81 Account Code Current Pmts MECHANICAL - NONRES PLAN CHECK - NONRES 000.322.102.00.00 274.25 000.345.830 68.56 Total: $342.81 doc: Receiot -06 Printed: 09 -21 -2011 07 -02 -2012 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director JOHN MURDOCH PO BOX 3707 M/C 89 -14 SEATTLE WA 98124 RE: Permit No. M11 -131 BOEING #9 -53 9725 EAST MARGINAL WY S TUKW Dear Permit Holder: In reviewing our current records, the above noted permit has not received a fmal inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 08/27/2012. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 -431 -2451 to schedule for the next or fmal inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 08/27/2012, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File: Permit File No. M11 -131 `-a 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206 -431 -3670 • Fax 206 -431 -3665 • City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director JOHN MURDOCH PO BOX M/C 89 -14 SEATTLE WA 98124 RE: Permit Application No. M11 -131 BOEING #9 -53 9725 EAST MARGINAL WY S TUKW Dear Permit Applicant: In reviewing our current application files, it appears that your permit applied for on 09/21/2011, has not been issued by the City of Tukwila Permit Center. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or National Electrical Code every permit application not issued within 180 days from the date of application shall expire and become null and void. Your permit application will expire on 03/19/2012. If you still plan to pursue your project, a written request for extension of your application must be submitted to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit application. If it is determined that an extension is granted, your application will be extended for an addtional 90 days from the expiration date and you will be notified by mail. In the event that we do not receive your written request for extension or your request was denied, your permit application will expire, become null and void and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, fer Marshall it Technician File: Permit File No. M11 -131 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 • • PLAN EVIEW /ROUTING SLIP ACTIVITY NUMBER: M11 -131 DATE: 09 -21 -11 PROJECT NAME: BOEING #9 -53 SITE ADDRESS: 9725 EAST MARGINAL WY S X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DE ART ENTS: Building Division ti Ktilk Olasi•9-1-"t i-ire Prevention Public Works ❑ Structural Planning Division Permit Coordinator i DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete n DUE DATE: 09-22 -11 Not Applicable Comments: Permit Center:Use Only • INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route 41 Structural Review Required REVIEWER'S INITIALS: No further Review Required n DATE: APPROVALS OR CORRECTIONS: DUE DATE: 10-20-11 Approved ❑ Approved with Conditions X( Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28-02 Contractors or Tradespeople inter Friendly Page • General /Specialty Contractor A business registered as a construction contractor with LEI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company BOEING COMPANY, THE 3125442535 100 N Riverside M/C 5003 -4027 Chicago IL 606061596 Out Of State Corporation UBI No. 178005030 Status Active License No. BOEINC*294ML License Type Construction Contractor Effective Date 7/13/1971 Expiration Date 1/18/2013 Suspend Date Specialty 1 General Specialty 2 Unused Business Owner Information Name Role Effective Date Expiration Date SHRONTZ, F A Cancel Date 01/01/1980 Amount CONDIT, P M 24 01/01/1980 HDOG255200500 GIVAN, B E 10/01/2012 01/01/1980 WOODARD, R B 09/20/2011 01/01/1980 ACE AMERICAN INS CO CRUZE, D D 10/01/2010 01/01/1980 KING, C G $10,000,000.00 01/01/1980 22 BEIGHLE, D P HD0G24934780 01/01/1980 10/01/2010 COLLINS, T J 01/01/1980 09/22/2009 BUDINICH, T M ACE AMERICAN INS CO 01/01/1980 10/01/2007 READ, PAUL Secretary 01/01/2001 $5,000,000.00 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 5 FEDERAL INS CO 81312466 01/01/2002 Until Cancelled $12,000.00 01/14/2002 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 24 Ace American Insurance Company HDOG255200500 10/01/2011 10/01/2012 $10,000,000.00 09/20/2011 23 ACE AMERICAN INS CO HD0G25520051 10/01/2010 10/01/2011 $10,000,000.00 09/30/2010 22 ACE AMERICAN INS CO HD0G24934780 10/01/2009 10/01/2010 $10,000,000.00 09/22/2009 21 ACE AMERICAN INS CO HD0G23732841 A 10/01/2007 10/01/2009 $5,000,000.00 09/26/2008 20 ACE AMERICAN INS CO HDOG21734378 10/01/2006 10/01/2007 $5,000,000.00 09/25/2006 19 ACE AMERICAN INS CO HDOG21731869 10/01/2005 10/01/2006 $5,000,000.00 09/26/2005 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https://fortress.wa.gov/lni/bbip/Print.aspx 02/29/2012 230 CFM (TYP (8 "NECK) • 7 (TY C5� 250 CFM (TYP 4) (8 "NEC ( 750 CFM TYP 1) 0 CFM 14/12 ( 350 TYP FM 1M13 M500 26/16 UP 36/24 UP 26/4 CD \ 270 CFM 14/8 26/12 C 26/14 28/24 I■ n 28/24 300 CF (TYP 4 (Th 7Th REViEVVED FOR CODE COMPLIANCE APPROVED SEP 2 8 2011 City of T ila WILDING NG ISICN A,r_rono. - 600 CFM BBB o 5 0 INUATION SEE SHEET / RG 600 C' 2 (TYP 1) C\I CD 0 CD / RG \ 400 1 / CFM RG . �. • ■--i' v CFM'JA - FOR CON MATCH LINE 150 CFM (TYP 10X10 BBB 600 CFM 00 CFM CD YP A4 5 180 CFM (TYP 5) 700 CFM (TYP 2) 150 CFM AA A RG \ 700 CFM 2 (TYP 4 SEPARATE PERMIT REQUIRED FOR: D Mechanical O Electrical O Plumbing ❑ Gas Piping City of Tukwila BUILDING DIVISION 100 CFM EG 200 /CD \ (TYP ) 1 CFM � 6 / 10X8 REVISIONS No changes shall he made to the scope of work without prior approval of Tukwila Building Division. NOTE: i revisions will require a new plan submittal and may include additional plan review fees. EX GE \ERAL \OTES 1. SOUND —LINE ALL RECTANGULAR DUCTWORK. DUCT DIMENSIONS SHOWN ARE NET INSIDE DIMENSIONS. 2. DISCHARGE DUCTS FROM VAV TERMINAL UNITS TO BE SIZED PER SCHEDULE ON SHEET M3. SECURE PENETRATION. SEE DETAIL SECURE PENETRATION. SEE DETAIL TYP M501 FLAG NOTE SYMBOL SHOWN ON SECURE SIDE OF WALL. SECURE PENETRATION. SEE DETAIL TYP M501 FLAG NOTE SYMBOL SHOWN ON SECURE SIDE OF WALL. ACCESS FOR DUCT CLEANING (ON JUNK LAYER) CO\ STR,CTIO\ \OYES: ROOM 126B3: REMOVE SIX EXISTING DIFFUSERS & INSTALL FOUR REPLACEMENT DIFFUSERS AND TWO RETURN GRILLS IN NEW DROPPED CEILING; ALL PER DWG. 1M451. IN ROOM 11AA4; REMOVE TWO EXISTING CD6 DIFFUSERS AND ONE RG1 RETURN GRILLE. INSTALL TWO CD3 DIFFUSERS AND ONE RG2 RETURN GRILLE IN NEW DROPPED CEILING. AUG ,2.,7 2012 FILE COPY Penntt Na. M.I lH3I Mtn review approval Is subject to os and on Approval a1 ;;1 f > 4 documents not t3 he viol -1i; any i t I tole or ordlnanco. Receipt Y, ! •;4. 1' f .� : f If I s ., / .1 /i{ , /FL City b& BUILDING DIVISION 11 109 ®® ®o® ®® 00 EXIS TIN G BLDG 9- 53 M KEY PLAN NOT TO SCALE RECEIVED SEP 21 2011 PERMIT CENTER SYM A B C D E REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE R1 LAB REVISION RELOCATE DUCT TO CLEAR DOOR RECORD DRAWING REFEED 4 EXIST. DIFF. © CC -5.5 RELOC NCO LAB 170051 12011000 MJC MJC MJC RAD RWS KMR /LL KMR /RB KMR /RB RWS RWS 9.7.90 12.10.90 F ADD DETAIL 1/1M451 9686868 HARR 01/27/10 G MODIFY BR &T COMPUTING LAB 8.30.91 H INSTL DROPPED CEILINGS RMS 12BB3 & 11AA4 10697207 M.WONG 10428 -10 HARR RWS 06.17.10 09/07/11 08.27.03 przwzAwe ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED DRAWN L. DEWALT DATE CHECKED D. MEYER SUBTITLE FIRST FLOOR HVAC PLAN - NORTH CURRENT REVISION 10428 -10 SYMBOL DATE H 09/07/11 APPROVED BY DEPT. DATE ENGINEER D. MEYER CHECKED K. RAMSEY APPROVED K. RAMSEY APPROVED L. LAW 5.17.90 TITLE MECHANICAL MASTER BUILDING 9 -53.1 COL. A— CC /1 -6 DEV. CENTER, WA SHEET 1M13 JOB NO. 89065 COMP NO. DWG NO. 9- 53.1 -1M13 4 CI891 A: 09/15/11 „ 1Y” 2 ,I 1Y” 2 „ „ 1Y" 2 • 1Y" 2 iY" 2 1Y" 4 t •avl a „ „ „ Y" 4 „ ,1 TO SV #938 AT COL. A.2/10.3, SEE DWG. 1M264 FOR PIPING CON 'T H 11 • „ If 1 1 /4 11/2” EXISTING BUILDING 9 -53 11__1111. „ „ IIIMMMOMAMEM v 1"S UP - FOR CONT. SEE SHEET 2M263 UP 48" INSPECTOR'S TEST CONNECTION GE \ERAL \OTES FOR SHIELDING SEE SHEET A517. CO2 FIRE SUPPRESSION SYSTEM BELOW RAISED FLOOR. PIPE RUN ON THE SUB - FLOOR. 4. FOR GENRAL NOTES SEE SHEET 1M260. 5. SEE DRAWING 1A283 FOR REFLECTED CEILING PLAN. E' VES THIS AREA. 7. PENDENT HEADS: 155 DEG F, 1/2" NPT, K -5.6, STANDARD RESPONSE. CTE SEE WORMALD FIRE SYSTEMS DRAWING 21001063 SHEETS 1 -5 FOR AS -BUILT SPRINKLER SYSTEM AND DRAWING 27000310 SHEETS 1 -5 FO S -= ILT CO2 SYSTEM. ., CO \STRUCTION CTES REWORK SPRINKLER COVERAGE IN ROOM 12BB3 AS DETAILED ON DRAWING 09- 053 -M451. REMOVE THREE SPRINKLER HEADS IN ROOM 11AA4. FURNISH AND INSTALL THREE PENDENT HEADS IN NEW SUSPENDED CEILING, REVISE PIPING AS REQUIRED. FM- APPROVED 1" FLEXIBLE CONNECTIONS MAY BE USED FOR NEW HEADS. SEE GENERAL NOTE 7. 3. FABRICATION AND INSTALLATION OF THE FIRE PROTECTION PIPING SHALL CONFORM TO THE REQUIREMENTS SET FORTH IN NFPA CHAP. 13 AND FM CHAP. 2, SECTION 8. JOINT COMPOUND OR TAPE (NOT BOTH) SHALL BE APPLIED ONLY TO MALE THREADS. 4. NOTIFY BOEING FIRE DEPARTMENT 24 HOURS IN ADVANCE OF DOING WORK (206)655 -7700. THE SHUT -OFF VALVE SV #938 IS LOCATED AT COL. A.2/1 .. . REV!EVVEL, OR CODE COMPLIANCE APPROVED SEP 2 8 2011 City of 111 1 1L6�ER9 DiVIS ) EX I ED AUG 27 2012 KEY PLAN X111 -131 A.4 RECEIVED SEP 212011 PERMIT CENTER SYM A B C D E REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE R1 LAB REVISION RECORD DRAWING RELOCATE NCO LAB 12011000 FOR ESTIMATE ONLY: ADD HEADS UNDER DUCTWORK 9686868 ADD DETAIL 1/1M451 9686868 MJC MJC RWS HARR HARR KMR /LL KM R/RB RWS 9.7.90 F MODIFY BR &T COMPUTING LAB 8.30.91 G DROPPED CEILINGS ROOMS 12863 & 11M4 10697207 10428 -10 M.WONG HARR RWS 06.17.10 09/07/11 08.25.03 10/21/09 01/27/10 Q�BOE /NG° ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED DRAWN M. CAUNITIS CHECKED f. EACRETT DATE SUBTITLE FIRE PROTECTION CURRENT REVISION 10428 -10 SYMBOL G., DATE 09/07/11 APPROVED BY DEPT. DATE ENGINEER I. EACRETT CHECKED K. RAMSEY APPROVED K. RAMSEY APPROVED L. LAW 5.17.90 TITLE (DISCIPLINE) MASTER BUILDING 9 -53.1 COL. A- CC /1 -6 DEV. CENTER, WA SHEET 1M263 JOB NO. COMP NO, DWG NO, 09-053-1M263 WONGK: 06/17/10 09:07 30' -10 7/8" B 1 -1 4" • 26 14 30 24 AliMhirmill I____ I 111 IIuI_i_r/ Q !Al SIM • i �, / / % ' 22/14 / 1 AMNIA B H mi EN z N CO I M E \LARGER PLA\ — EXISTI\ SCALE: 1/4" = 1' -0" (1� 1M13 1M451 1M263 30/29 ME= AmpasrawymNarmspl ■061VairmMilmomftm 1Eir rG ■ • mammon �� DY imimpami NE N ■ N 1__i'IIIUL I 1� � = ice :� w4IVAIIP.-AfM �22/14/ �, i 1 "Ir411/11/111 M' MIMI IONE. 1111 1111-111nr ."-wimm-rin I MIME* mom I HMI 11111 1 z E \LARGE PLA\ — PROPOSES 1 SCALE: 1/4" = 1' -0" 1M13 1M451 1M263 BB �g c LEGE B — LIGHT FIXTURE SPRINKLER HEAD ON FLEX CONNECTOR SUPPLY DIFFUSER RETURN GRILLE GE \ERAL \CTES 1. THIS DRAWING CREATED FROM FIELD MEASUREMENTS AND PHOTOGRAPHS TO ADDRESS OBSTRUCTION OF SPRINKLER COVERAGE BY DUCTWORK. 2. EXISTING SPRINKLER HEADS ARE UPRIGHT TYPE. (PENDANT SYMBOL USED TO MAKE MORE VISIBLE.) 3. MAJOR DUCTWORK IS CROSS- HATCHED TO MORE CLEARLY SHOW ROUTING AND OBSTRUCTIONS. 4. NEW PENDENT HEADS: 155 DEG F, 1/2" NPT, K -5.6, STANDARD RESPONSE. EVIEVVEL FOR DE COMPLIANCE APPROVED SEP 2 8 2011 City of Tukwila f UILOICIO DIVISION REFERE \C DAWI \GS CO\ STRUCTIO � \OYES REMOVE SPRINKLER HEADS. REMOVE BRANCH LINE OR ABANDON IN PLACE. REMOVE FOUR EXISTING SUPPLY DIFFUSERS. REMOVE TWO EXISTING ROUND DIFFUSERS SERVING AS RETURN GRILLES. FURNISH & INSTALL FITTINGS AND PIPE TO VICINITY OF NEW SPRINKLER HEAD LOCATIONS. FURNISH & INSTALL NEW PENDENT HEAD IN NEW CEILING, CONNECTED TO PIPING WITH FM- APPROVED 1" FLEXIBLE CONNECTIONS. SEE GENERAL NOTE 4. FURNISH at INSTALL FOUR CD3 SUPPLY DIFFUSERS. CONNECT TO EXISTING BRANCH DUCTS. SEE SCHEDULE DWG M361. / FURNISH & INSTALL TWO RD2 RETURN GRILLES. CONNECT TO EXISTING BRANCH DUCTS. SEE SCHEDULE DWG M361. 9. FABRICATION AND INSTALLATION OF THE FIRE PROTECTION PIPING SHALL CONFORM TO NFPA CHAP. 13 AND FM CHAP. 2, SECTION 8. FIELD VERIFY EXISTING PIPE SIZES TO CONFIRM COMPLIANCE. 10. NOTIFY BOEING FIRE DEPARTMENT 24 HOURS IN ADVANCE OF DOING WORK (206)655 -7700. THE SHUT -OFF VALVE SV #938 IS LOCATED AT COL, A.2/10.3. EX f'r AUG 27 2012 M II- 131 RECEIVED SEP 21 2011 PERMIT CENTER SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE A INSTALL DROPPED CEILING 10428 -10 HARR 09/07/11 pirOE /NG° ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED DRAWN HARR CHECKED DATE 01.21.10 SUBTITLE ENLARGED PLAN CURRENT REVISION 10428 -10 SYMBOL DATE 09/07/11 APPROVED BY DEPT. DATE ENGINEER HARR 01.21.10. CHECKED APPROVED APPROVED TITLE MECHANICAL MASTER BUILDING 09 -053 COL. CC- BB /2 -4 DEV. CENTER, WA SHEET 1M451 JOB NO. 10428 -10 COMP NO. DWG NO. 09- 053 -1M451 0 0 CI891 A: 09/07/11