HomeMy WebLinkAboutPermit M11-132 - WESTFIELD SOUTHCENTER MALL - BERGMAN LUGGAGEBERGMAN LUGGAGE 102 SOUTHCENTER MALI. Mi 1 -132 Parcel No.: Address: City mot' Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov MECHANICAL PERMIT 9202470010 102 SOUTHCENTER MALL TUKW Project Name: BERGMAN LUGGAGE Permit Number: M11 -132 Issue Date: 10/17/2011 Permit Expires On: 04/14/2012 Owner: Name: Address: Contact Person: Name: Address: Email: WESTFIELD PROPERTY TAX DEPT PO BOX 130940 , CARLSBAD CA 92013 SCOTT RAEDER 2921 MERIDIAN AV E , EDGEWOOD WA 98371 SCOTIR a(AIREPRO.COM Contractor: Name: AIRE PRO INC Address: 1112 S 344 ST STE 303 , FEDERAL WAY 98003 Contractor License No: AIREPI *032RU Phone: 253 848 -2626 Phone: 253 942 -7028 Expiration Date: 03/18/2012 DESCRIPTION OF WORK: INSTALL 5 -TON SPLIT SYSTEM HEAT PUMP AND AIR DISTRIBUTION SYSTEM (7 SUPPLY & 2 RETURN GROS). Value of Mechanical: $16,900.00 Type of Fire Protection: SPRINKLERS /AFA Electrical Service Provided by: Permit Center Authorized Signature: I hereby certify that I have read art governing this work will be compli Fees Collected: $391.81 International Mechanical Code Edition: 2009 IQDate: WM\ ed this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. The granting of this permit does not construction or the performance of wo back of this permit. Signature: to give authority to violate or cancel the provisions of any other state or local laws regulating m authorized to sign and obtain this mechanical permit and agree to the conditions on the Date: (1) Print Name: . (L2;.0rl� This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. IMC -4/10 M11 -132 Printed: 10 -17 -2011 PERMIT CONDITIONS Permit No. M 11 -132 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: Readily accessible access to roof mounted equipment is required. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 8: Manufacturers installation instructions shall be available on the job site at the time of inspection. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IMC -4/10 M11 -132 Printed: 10 -17 -2011 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http: //Www. TukwilaWA.00v Building Permit No. /►� Mechanical Permit No I ►1%` /3a Plumbing/Gas Permit No. Public Works Permit No. Project No. (111 (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION 10a 39tc rI'1Ce A-er 6101 Site Address: Tenant Name: Oe le& �YFi Llgsoir,4 G King Co Assessor's Tax No.: //V 4' 1 — I 0 Suite Number: (pie, Floor: t New Tenant: Er/ Yes ❑ ..No Property Owners Name: 5) (,q l G e tw 1 crV Y1,‘ IA ti,/ WV "(f t t I-0 Mailing Address: Zip City State CONTACT PERSON — who do we contact when your permit is ready to be issued Name: Q m eo (;mot m_. - / Day Telephone: g3—eio ` Lbi10 Mailing Address: Z4i t 12. i0I f4 ft � {� j e igy( Ca,t' (,l/jj O P (4'J - City State Zi Fax Number: 2"5-3 -Q'f4 - 7-07-41 07-41 E -Mail Address: 5c4) -it iP 14.4e mu. C.L GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: Mailing Address: Zip Contact Person: E -Mail Address: Contractor Registration Number: City Day Telephone: Fax Number: Expiration Date: State ARCHITECT OF RECORD — All plans must be stamped by Architect of Record Company Name: Mailing Address: State City Contact Person: Day Telephone: Fax Number: E -Mail Address: Zip ENGINEER OF RECORD — All plans must be sta>iped by Engineer of Record Company Name: Mailing Address: State City Contact Person: Day Telephone: E -Mail Address: Fax Number: Zip H:\Applications \Forms - Applications On Line \2010 Applications \7 -2010 - Permit Application.doc Revised: 7 -2010 bit Page 1 of 6 • • MECHANICAL PERMIT INFORMATION — 206-431 -3670 MECHANICAL CONTRACTOR INFORMATION Company Name: (A IfLt:' J'(LO ] /VG. /� / /� Mailing Address: j411\ . v' 1'�R'l 01 AI✓ n V�/ F i, ��00 (,l/DVO ✓V4. "1 611 City C State Zip Contact Person: 5-co 1 f R A a 2- Day Telephone: 2✓3 '$k4. Z%Zlo E -Mail Address: scoff r A 0, Qz Pgo • tpM Fax Number: SO -0110— vo zi Contractor Registration Number: AIR V 321p [ 0-, Expiration Date: l�l0 —VI' Valuation of Mechanical work (contractor's bid price): $ Iii 40. CO ,/J Scope of Work (please provide detailed information): J A/ 14t 1s lo 5 %1r 1 r �JhxjTc. FIk. p r I' u rviiP atit At' P tVa.,10t. ioVV J�r,IY 1 C 1 9apoc't t, ee rw n/ &R ,o) Use: Residential: New .... O / Replacement .... ❑ Commercial: New .... �J1 Replacement .... ❑ Fuel Type: Electric Gas.— ❑ Other: Spl,l t Om }-I 7u mn Indicate type of mechanical work being installed and the quantity below: Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Fumace<100K BTU Air Handling Unit >10,000 CFM 1 Fire Damper 0-3 HP /100,000 BTU Fumace>100K BTU Bvapecatar.6eolez. 0007 yiOW 141P (opj(4 I Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct . Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30-50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM Incinerator — Comm/Ind H:WpplicationsWorms- Applications On Line\2010 Applications \7 -2010 - Permit Application :doe Revised: 7 -2010 bh Page 4 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4 -3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: "L) IV �i�i I'-116179.4/ Date: q- 23 -1/ Print Name: L) g4 (.00� � Day Telephone: tI ?f' —011t) 2b Z/0 / Mailing Address: //PA I'1 v fi did Fr 17�9'1 [Pine 144 gel3 City State Zip Date Application Accepted: Date Application Expires:�� /[� H:Wpplicat ions\ Fortes- Applications On Line \2010 Applications \7 -2010 - Permit Application.doc Revised: 7 -2010 bb Staff Initials: A W Page 6 of 6 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: / /www.TukwilaWA.gov RECEIPT Parcel No.: 9202470010 Permit Number: M11 -132 Address: 102 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 09/22/2011 Applicant: BERGMAN LUGGAGE Issue Date: Receipt No.: R11 -02086 Payment Amount: $391.81 Initials: LAW Payment Date: 09/22/2011 02:11 PM User ID: 1632 Balance: $0.00 Payee: AIRE PRO INC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 20088 391.81 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts MECHANICAL - NONRES PLAN CHECK - NONRES 000.322.102.00.00 313.45 000.345.830 78.36 Total: $391.81 doc: Receiot -06 Printed: 09 -22 -2011 1 SPECTIQN NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION •6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Pr ect : ' " •--- 8e.11 ' L./19 A 5 6., Type of Insp e ion : f1 . £A P,P /Li 2 Address: '- _ . / .? 07- SC. 41/ Date Called: - Spec al liiit ctions: ' ' r I Date Wanted:. ! te," 2-8-""` (( �a.ae p.m. Requester: Phone No: • Approved per applicable codes. a Corrections required prior to approval. COMMENTS - - • Datf 0 z � f REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be == paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit 4L, M(( -t324 Ati INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Proj : 1St(d (MNJ L 6 e Type of Inspection: g..e . ft:. el-�-' • 5--N Address• I 0't C_ ,(A t Date Called: Special Instructions: (Q Date Wanted:. . a.m. t 0 - ZS - (( p.m. Requester: . Phone No Z53 — 21(2— aV2 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: 253 2, : -r12,10 ei) Insp ct� or: T7 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. �•. INSPECTION NO, :•.C1'TY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 INSPECTION RECORD Retain a copy with permit PERMIT NO. Pro ect: . ` • Typ of Inspection: Address: %0 „!} / Date Called: — Special Instructions: • � r i ?9 471/. r .. : • • o4S'yGCc.-c2? Date Wanted:. agile '/ O .2t/ —�f a.m. Requester:. Phone No: mZ'S -A132 -88o? pproved per applicable codes. aCorrections required prior to approval. COMMENTS: EINS�ECTION FEE REQ IRED. Prio o next inspection. fee must be paid 6300 Southcenter tvd., Suit 100. Call to schedule reinspection. O O (i) APPRWC. 60130. WM � WINFIELD STANDARDS Elk ® II VP REVIEWED R PL CODAPPR VE'D OCT APPROX. ZOICW OW PER WE517113.0 STANDARDS orinfiliKi 1111 %�i1wai arii<""r,_ r 1111mu■11u1111r . iiIiRiRiIIkii 61111611•1121111111111111E•111 _ PUIUUUflU!I�t■�r� �I_ rAiu C��� Enter ■-.wr:��l� •I/ „m a i Ein�1��al■■ lime I!i ;� ■ ■11Av�, « ■ ■■ ■■■ laimnam Emma gain ■ ■1111■■ ■1111■■• Reflected Ceiling Plan` U�ila NISI ECM OF .x.82 WESTFIELD MALL AT SOUTHCENTER DESIGN REVIEW DOCUMENT #4 - NOT FOR CONSTRUCTION - 28JU4Y2011 1 FILE copy .AR • 34 FEET 1 O 0 Vir i6 374 CFM 1 P -10 :10 "RND 0 «ml,pCAM 6)SEC IONS 24X8 FGDB ,M 375 CFM 104P -10 10"RND 3) SECTIONS 16X8 i FGDB _d 104P -8 8 �RND 0 i SHOW ROCU OM 1500 CFM 24 X 24 RAG 20" RND • . 1 SECTION 28 X 10 FGDB uomsoea� _ •A it Fri Et Wag LUCCA 1 Meu. Reflected Ceiba Plan 12 FOOT CEILING 375 CFM 104P -10 10" RND ...... al a G CV a L U v CAL �i■ LL1C) la— U LU 41 FEET I375 CFM - J �- 1104P-10 450 CFM 110» RND �2X12RAG 12" RND 125 CFM 125 CFM 104P-6 , 6" RND 16" RND SCALE 3/32" =1' THE AREA REQUIRES ONE (1) FIVE TON SPLIT SYSTEM HEAT PUMP BERGMAN LUGGAGE -SOUTH CENTER MALL 1 I A2.0 CW Reflected CPlan • DETAILED ZONE LOAD REPORT System: COMMERCIAL 1 Location: Seattle- Tacoma, Washington Prepared by: AIRE PRO INC. Block Load 3.05 August 04, 2011 Page: 1 TABLE 1. GENERAL INFORMATION Zor4Name: BERGMAN LUGGAGE System Name: COMMERCIAL 1 Design Load: June 17:00 r • Db/Wb Temp: 80.8/ 64.3 F TABLE 2. LOAD COMPONENT SUMMARY Load Component Details Design Cooling Loads Sensible (BTU/hr) Design Heating ( BTU/hr) Solar Loads • 128 sqft 2,801 - Wall Transmission 1,672 sqft 1,056 4,096 Roof Transmission 1,394 sqft Z956 6,148 Glass Transmission 128 sqft 212 3324 Skylight Transmission 0 sqft 0 0 Partitions 0 sqft 0 0 Lighting 2.00 W/sqft 9,495 - Other Electric 0.00 W /sqft - 0 - People 54 People 13,119 - Infiltration , 344 431 3,637 Miscellaneous NE 6,000 - Slab 1,394 sqft - 2,519 Pulldown/Warm -Up 1,898 0 - Safety Factor 0/ 0 % 0 0 Total Zone Loads 0 36,070 19,724 TABLE 3. WALL AND GLASS BREAKDOWN - Component Total Net-Area (sgft) Cooling Transmission (BTU/hr) Cooling Solar Load (BTU/hr) Heating Transmission (BTU/hr) NE 0 0 - 0 E 428 355 - 1,�,4 SE 0 0 - 0 S 408 303 - 1,000 SW 0 0 - 0 W 492 299 - 1,205 NW 0 0 - 0 N , 344 98 - 843 NE 0 0 0 0 E 64 106 1,898 1,66 SE 0 0 0 S 0 0 0 SW 0 0 0 0 W 0 0 0 0 NW 0 0 0 0 N. 64 106 903 1,662 Hor 0 0 0 0 Walls: Glass: RtetiV41 __ ail OF TUKVVILA SFP222011 PERMIT CENTER REVIEWED FOR CODE COMPLIANCE APPROVED OCT 14 2011 City of 7. UILDING LikWiIa DIVISION Mt12. SYSTEM SIZING SUMMARY System: COMMERCIAL 1 Location: Seattle- Tacoma, Washington Prepared by: AIRE PRO INC. Zone Name: BERGMAN LUGGAGE Block Load 3.05 August 04, 2011 Page: 1 TABLE 1. SIZING DATA (COOLING) Total Coil Load Sensible Coil Load Total Zone Sensible Supply Temperature Supply Air (Actual) Supply Air (Standard) Ventilation Air Direct Exhaust Air Reheat Required 52,589 BTU/hr 50,729 BTU/hr 35,804 BTU/hr 57.0 F 1,868 CFM 1,842 CFM 1,340 CFM 0 CFM 0 BTU/hr Floor Area 1,394 sqft Overall U -Value 0.087 BTU/hr/sqft/F' Vent Air 0.96 CFM/sqft Vent Air 25.00 CFM/Person TABLE 2. SIZING DATA (HEATING) Heating Coil Load 89,673 BTU/hr Ventilation Load Total Zone Load Ventilation Airflow Supply Airflow 69,949 BTU/hr 19,724 BTU/hr 1,340 CFM 1,868 CFM Load Occurs Outdoor Db/Wb Coil Conditions: Entering Db/Wb Leaving Db/Wb Apparatus Dewpoint Bypass Factor Resulting Zone RH July 15:00 84.0/65.0 F 81.5/64.8 F 56.0/55.2 F 54.6 F 0.050 55.5 % Total Coil Load 4.38 Ton Sensible Coil Load 4.23 Ton SQFT/Ibn 318.09 Cooling c 134 CFM /soft i Heating Heating Floor Area Overall U -Value Vent AIr Vent Air 1.34 CFM/sqft 1,394 sq 0.087 0.96 CFM/sqft 25.00 CFM/Person TABLE 3. INPUT DATA (WEATHER) Location Data Source Latitude Elevation Seattle- Tacoma, Washington Carrier Defaults 47.5 Degree 386.0 ft Atmovnheric Clearneaa 8 1.05 TABLE 4. INPUT (HVAC SYSTEM) System Name COMMERCIAL 1 THERMOSTAT SETPOINTS System Type Cig and Warm Air Ht Cooling (Occ.) 75.0 F System Start 6:00 Cooling (Unocc.) 75.0 F Duration 24 hrs Heating 70.0 F SIZING SPECIFICATIONS RETURN AIR PLENUM No Supply 57.0 F FAN Ventilation 25.00 CFM/person Configuration Draw -Thru Exhaust 0.00 CFM Static Pressure 1.5d in. wg. Summer Dry-Bulb _ Coincident Wet -Bulb Daily Range Winter Drv-Bulb 84.0 F 65.0 F 22.0 F 21.0 F 1 FACTORS Coil Bypass 0.050 Safety (Sens) 0 % Safety (Latent) 0 % Heating Safety 0 % TABLE 5. TOP TEN COOLING COIL LOADS Time 1) July 15:00 2) June 15:00 3) July 16:00 4) June 16:00 5) August 15:00 Sensible Ton Total Ton 4.23 4.38 4.11 4.38 4.17 4.32 4.05 4.31 4.15 4.30 Time 6) July 14:00 7) June 14:00 8) August 16:00 9) August 14:00 10) July 17:00 Sensible Ton 4.11 4.00 4.09 4.04 3.98 W i'<fri Total Ton 4.26 , 4.25 4.23 4.17 4.12 SYSTEM SIZING SUMMARY System: COMMERCIAL 1 Location: Seattle- Tacoma, Washington Prepared by: AIRS PRO INC. Zone Name: BERGMAN LUGGAGE Block Load 3.05 August 04, 2011 Page: 2 TABLE 6. ZONE SIZING DATA Zone Name Max. Cooling Design Airflow Max. Heating Design Flow Sensible Rate Load Rate (BTU/hr) (CFM) Design Time (BTU/hr) (CFM) BERGMAN LUGGAGE 36,070 1,882 June 17:00 19,724 t)41 ZEEKS PIZZA 0, TRANS® TAG: HP - 1 NOTE: All dimensions are in mm /inches. vo COO B :('.lit 282(1- - - ((2.1.08. 880 w- 'rTTPy�I 5 1=b REVIEW�b R CODE COMPLIANCE APPROVED OCT 14 2011 City of Tukwila BUILDING D IVI10 K - -- 2A4r1 - -r ICi '1./'x02 28 6 8, '88: 08* A 0. - __- t! '!181 2 A *0l( 14 2088202 SO, 81,208 202 fi(u2t021 22812 1:18211 ;8110 x 21 0122'21 ::1. 1 0 1,422( BR8/ H (026(08 06 8.1 22( F 2.22(2 r2022t:2(111284r 811126 102 112822801 8222 580410 0( U4R(01218I(0 (02 AT 1(818 (088 0. UP! 80081 (211 MI 020010 (( 2181.222 SO 8008 202.018 08118 002:0 80! 2 028 2188C1t1 04 2411, 140 8401180 01 AS 16821 005 118'8 181* 0211 282 A11 9282008010 (28088(81 02 181 080.81. 31R1F (80 0(011 028201:100 T i_� FIG. I .■28 4 •'812 9x11 0[Pl((( 1 D. 1141 (921728 104011!'04 Se( 11828 YF1 1/.180 188 1!'1120 From Dwg, 21 D153074 Rev. 13 EIVF ,j�_ CITY REC QF TUKKWLA SFP 2 2 2011 PERMIT CENTER 4TWA3060- SUB - 104.00 5 Ton Split System Heat Pump - 3 Phase 4TWA3060A Product Specifications OUTDOOR UNIT 00 4TWA3060A3000A 4TWA3060A4000, POWER CONNS. - V /PH /HZ O 200/230/3/60 MIN. BRCH. CIR. AMPACITY 24 BR. CIR. t MAX. (AMPS) 40 PROT. RTG. j MIN. (AMPS) 40 460/3/60 12 20 20 COMPRESSOR CLIMATUFP- SCROLL NO. USED - NO.SPEEDS 1 -1 VOLTS /PH /HZ 200/230/3/60 R.L. AMPS 0 - L.R. AMPS 18.1 - 137 FACTORY INSTALLED START COMPONENTS ® NO INSULATION /SOUND BLANKET NO COMPRESSOR HEAT YES CLIMATUFP -SCI 1 -1 460/3/60 9.0 - 62 NO NO YES OUTDOOR FAN PROPELLER DIA. (IN.) - NO. USED 27.6 - 1 TYPE DRIVE - NO. SPEEDS DIRECT - 1 CFM @ 0.0 IN. W.G. ® 4800 NO. MOTORS - HP 1 - 1/4 MOTOR SPEED R.P.M. 825 VOLTS /PH /HZ 200/230/3/60 F.L. AMPS 1.3 PROPELLEF 27.6 - 1 DIRECT - 1 4800 1 - 1/5 825 460/3/60 0.6 OUTDOOR COIL - TYPE SPINE FINTM ROWS - F.P.I. 1 - 24 FACE AREA (SQ. FT.) 27.86 TUBE SIZE (IN.) 3/8 REFRIGERANT CONTROL EXPANSION VALVE SPINE FIN"' 1 - 24 27.86 3/8 EXPANSION VA REFRIGERANT LBS. - R-410A (0.D. UNIT) © 9 LBS. - 7 OZ. FACTORY SUPPLIED YES LINE SIZE - IN. 0.D. GAS O 7/8 LINE SIZE - IN. O.D. LIQ. O 3/8 9 LBS. - 7 02 YES 7/8 3/8 CHARGING SPECIFICATION SUBCOOLING 13 °F 13 °F DIMENSIONS HXWXD CRATED (IN.) 46.4 x 35.1 x 38.7 HXWXE 46.4 x 35.1 x 3 WEIGHT SHIPPING (LBS.) 297 NET (LBS.) 261 296 260 7 '1 (nrhfind m arrnrrianrw with tho Air- Snurre Unitary Heat Pumo Eouioment certification oroaram. which is based on ARI standard 210/240. O Rated in accordance with ARI standard 270. ti% Calculated in accordance with Natl. Elec. Codes. Use only HACR circuit breakers or fuses :8 Standard Air - Dry Coil - Outdoor 1) This value approximate. For more precise value see unit nameplate. if) Max. linear length 60 ft.; Max. lift - Suction 60 ft.; Max lift . Liquid 60 fl. For greater length consult refrigerant piping software Pub. No. 32. 3312 -0' (' denotes latest revision). L? This value shown for compressor RLA on the unit nameplate and on this specification sheet is used to compute minimum branch circuit ampacity and max. fuse size. The value shown is the branch circuit selection current. No means no start components. Yes means quick start kit components. PTC means positive temperature coefficient starter. C LV MODELS BASE FIG. A B C D E F G H J K 4TWA3060A3 /4 4 1 1045 (41 -1/8) 946 (37 -1/4) 870 (34 -1/4) 7/8 3/8 152 (6) 98 (3 -7 /8) 219 (8 -5/8) 86 (3 -3/8) 508 (20) A- weighted Sound Power Level [dB(A)] MODEL SOUND POWER LEVEL [dB(A)] A- WEIGHTED FULL OCTAVE SOUND POWER LEVEL dB - [dB(A ] 63 125 250 500 1000 2000 4000 8000 4TWA3060A3 /4 78 45.3 55.1 66.6 73 73.5 69.7 63.1 53.9 Note: Tested in accordance with ARI Standard 270.95. (Not listed with ARI) © 2006 American Standard Inc. All Rights Reserved . 6 M11- 132 TRANE" Tune A business of American Standard Companies www.trane.com Mechanical Specification Options General The 4TWA3 shall be fully charged from the factory for matched indoor section and up to 15 feet of piping. This unit must be designed to operate at outdoor ambient temperatures as high as 115 °F. Cooling capacities shall be matched with a wide selection of air handlers and furnace coils that are A.R.I. certified. The unit shall be UL listed. Exterior must be designed for outdoor application. Casing Unit casing is constructed of heavy gauge, galvanized steel and painted with a weather - resistant powder paint. Corrosion and weatherproof CMBP -G30 DuratuffTM base. Refrigerant Controls Refrigeration system controls include condenser fan and compressor contactor. High and low pressure controls are inherent to the compressor. Another standard feature is the liquid line dryer. Compressor The ClimatufP compressor features internal over temperature and pressure protector and total dipped hermetic motor. Other features include: roto lock suction and discharge refrigeration connections, centrifugal oil pump, and low vibration and noise. The Climatuff compressor is standard with a 5 year limited warranty. ARI Standard 210/240 UHP Us Condenser Coil The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by louvered panels and has a 5 year limited warranty. Low Ambient Cooling As manufactured, this unit has a cooling capability to 55 °F. The addition of an evaporator defrost control permits operation to 40 °F. The addition of an evaporator defrost control with TXV permits low ambient cooling to 30 °F. Accessories Thermostats — Heating /Cooling (manual and automatic changeover). Sub -base to match thermostat and locking thermostat cover. Evaporator Defrost Control — See Low Ambient Cooling. Trans has a policy of continuous product and product data improvement and it reserves the right to change design and specifications without notice. 9/06 TAG: 5 Ton Convertible Air Handler 2 /4TEC3F60B1000A -- D I OPE (Si it HEM REVIEWED FOR GEODE COMPLIANCE APPROVED 0. 88' Y 1.38" DUCT fUNGES 1Srf I10 1 5 FIG 1 OEVERSi811 5.10 I-- TOP VIEW OCT 14 2011 TEC3F60 -SUB -1 F SUBMITTAL rA City of Tukwila A �- BUILD SIG DIVISI •' 1 LII 56 i NNEANEN i.38:1----- 2.00 OAS LINE SEE TABLE L10010 LINE SEE TABLE 3/4.1A IAPLRED PIPE THREAD 33 5.23 CO SIDE VIEW 1001.--1801_1ri01 00J— BOTTOM VIEW RECEIVER„ CITY OF TU LA SEP 2 2 2011 PERMIT CENTER IfR AC [SS VERTICAL UPFLOW RG. 1 Pin B8 FIG. 2 MINIMUM UNIT CLEARANCE TABLE TO COMBUSTIBLE MATERIAL 1RE011RE01 5ERV/20 CLEARANCE :RECOMMENDE01 SIDES 0• 2'. 1R0N1 0' 21- BACA 0' o- 11101 DOC 1 0• t' 031LET DUCT . 1. 1011 1P 7151 3 II 01 031111 OUC' WHIN 1-11(10 C RIAIIRS ARE 111013111D EAC1P1 MODE 5 DAYNIRIA05, 1108. AND 1110 ARE APPROVE !0R 0' PAIN* AND D1121 CLEARANCE 1 1112 UP110W CONEIGORA1 01 ONLY ON 1141 P MOWS. MODEL NO. FIG.1 B FIG 2. D E MODEL NO. J K J K L 2/4TEC3F48, 60 12.02 21.22 11.02 20.22 31.15 MODEL NO. A B C D E F G H Flow Control R22 Gas Line BRAZE R22 Liq. Line BRAZE R -410A Gas Line BRAZE R-410A Liq. Line BRAZE 2 /4TEC3F6OB 57.90 23.50 21.50 30.47 4.65 6.77 3.62 1.89 TXV /NB 1 -1/8 3/8 7/8 3/8 © 2007 American Standard Inc. All rights reserved MU U3Z PRODUCT SPECIFICATIONS MODEL 2/4TEC3F60B1000A RATED VOLTS/PH/HZ 208 - 230/1/60 RATINGS 0 See O.D. Specifications INDOOR COIL — Type Plate Fin Rows — F.P.I. 3 -14 (3-16, 4TEC) Face Area (sq. ft.) 6.19 Tube Size (in.) 3/8 - Copper Refrigerant Control TXV - NonBleed Drain Conn. Size (in.) ® 3/4 NPT DUCT CONNECTIONS See Outline Drawing INDOOR FAN — Type Diameter -Width (In.) No. Used Drive - No. Speeds CFM vs. in. w.g. No. Motors — H.P. Motor Speed R.P.M. Volts/Ph/Hz F.L. Amps Centrifugal 11X10 1 Direct - 4 Q See Fan Performance Table 1 -1 1050 200-230/1/60 7.6 FILTER Vertical Applications Filter Fumished? Type Recommended No. -Size- Thickness Horizontal Applications Filter Fumished? Recommended Size 0 Yes High Velocity 1 - 20X22 -1in. No See Note ® REFRIGERANT Ref. Line Connections Coupling or Conn. Size — in. Gas Coupling or Conn. Size — in. Liq. DIMENSIONS Crated (In.) Uncrated WEIGHT Shipping (Lbs.) / Net (Lbs.) R -22 R -410A Brazed Brazed 1 -1/8 7/8 3/8 3/8 HxWxD 59 -1/2 x 26 x 23 -1/2 See Outline Drawing® 170 /155 O These Air Handlers are A.R.I. certified with various Split System Air Condi- tioners and Heat Pumps (ARI STANDARD 210/240). Refer totheSplit System Outdoor Unit Product Data Guides for performance data. O 3/4" Male Plastic Pipe (Ref.: ASTM 1785-76) O Minimum filter size for horizontal applications will be based on airflow selec- tion and will be calculated as follows: Low Velocity Filter: Face area (Sq. Ft.) = CFM / 300 High Velocity Filter: Face area (Sq. Ft.) = CFM / 500 0 The cabinet for this unit is made of two pieces, making it easier to assemble In attics or tight applications. 0 Torque Spec for TXV = Tighten 1/6 turn passed finger tight US Airflow Performance 2/4TEC3F60B: Wet coil, No Heaters EXTERNAL STATIC PRESSURE (in.w.g.) AIRFLOW (CFM) VERTICAL HORIZONTAL 230 VOLTS 208 VOLTS 230 VOLTS 208 VOLTS HI MED -H M -LO Low HI MED -H M -LO Low HI MED -H M -LO Low HI MED -H M -LO Low 0 2163 2018 1901 1831 2129 1988 1893 1820 2107 1963 1840 1774 2085 1956 1837 1777 0.1 2132 1974 1852 1796 2091 1954 1833 1769 2063 1927 1810 1743 2049 1912 1797 1729 0.2 2088 1936 1811 1754 2049 1915 1790 1722 2028 1889 1773 1706 2011 1870 1756 1683 0.3 2044 1901 1775 1709 2008 1874 1756 1678 1995 1851 1735 1663 1973 1830 1716 1638 0.4 2004 1867 1741 1663 1970 1835 1723 1634 1962 1814 1698 1617 1934 1793 1678 1593 0.5 1972 1832 1707 1617 1935 1797 1687 1590 1925 1778 1662 1569 1896 1757 1641 1548 0.6 1941 1797 1672 1572 1899 1761 1646 1542 1883 1743 1628 1520 1855 1721 1606 1501 0.7 1902 1760 1635 1526 1858 1725 1602 1489 1834 1710 1595 1473 1812 1685 1570 1450 0.8 1841 1721 1594 1475 1803 1684 1556 1427 1779 1678 1559 1429 1761 1648 1531 1392 0.9 1735 1683 1549 1416 1722 1636 1516 1354 1719 1648 1518 1389 1699 1606 1484 1326 NOTES: With fil er, no horizontal drip tray Small apex baffle Subtract 0.06° W.G. for downflow As shipped except without filter Subtract 0.05" W.G. for horizontal left SEE AIR FLOW RESISTANCE TABLE FOR PRESSURE LOSS WITH SUPPLEMENTARY HEATER. es City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director 1908 October 4, 2011 Scott Raeder 2921 Meridian Ave E Edgewood, WA 98371 RE: Correction Letter #1 Mechanical Permit Application Number M11 -132 Bergman Luggage —102 Southcenter Mall Dear Mr. Raeder, This letter is to inform you of corrections that must be addressed before your mechanical permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. The Fire Department does not have any comments at this time. Building Department: Allen Johannessen at 206 433 -7163 if you have any questions regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3670. Sincerely, W,6 't er Mar all Technician e File: 1 -132 W:\Permit Center\Correction Letters \ 2011%411 -132 Correction Letter #1.doc 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 0 Building Division Review Memo Date: September 30, 2011 Project Name: Bergman Luggage Permit #: M11 -1322 Plan Review: Allen Johannessen, Plans Examiner Tukwila Building Division Allen Johannessen, Plan Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and/or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. Please provide a plan view with detail for the method of tie down and location of the Heat pump. 2. Provide details for the installation of the air handler unit and ductwork that show how the unit and components are attached to the buildings structural framing. Specify seismic anchorage as well. 3. Specify insulated ducts and show where flex ducts are used with maximum lengths indicated. Specify sizes of ducts. 4. Provide clarification as to whether this system is in anyway tied into the malls mechanical ventilation system. If so provide details and specifications. 5. Please do not provide reduced size sheets (see general notes above). Plans and details submitted shall be to scale. Should there be questions concerning the above requirements, contact the Building Division at 206- 431 -3670. No further comments at this time. "PERMIT COORD CORD PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M11 -132 PROJECT NAME: BERGMAN LUGGAGE SITE ADDRESS: 102 SOUTHCENTER MALL Original Plan Submittal DATE: 10/07/11 Response to Incomplete Letter # X Response to Correction Letter # 1 Revision # after Permit Issued DEPARTMENTS: `i Building Division Public Works I Fire Prevention Structural Planning Division Permit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete n DUE DATE: 10 /11 /11 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 11 /08 /11 Approved ❑ Approved with Conditions Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 HERMIT CORD CORYM PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M11 -132 DATE: 09/22/11 PROJECT NAME: BERGMAN LUGGAGE SITE ADDRESS: 102 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMEN F1Ni Building Division Public Works ,11 off, ijU • ire Prevention �� n Structural Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete n DUE DATE: 09/27/11 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 10/25/11 Not Approved (attach comments) 5 DATE: Permit Center. Use Only 1 CORRECTION LETTER MAILED: 10 01'q (I Departments issued corrections: Bldg ty6 Fire ❑ Ping ❑ PW ❑ Staff Initials: ‘tniki Documents /routing slip.doc 2 -28 -02 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 10 -7-2011 Plan Check/Permit Number: M 1 1-132 ❑ Response to Incomplete Letter # • Response to Correction Letter # 1 eRVF ❑ Revision # after Permit is Issued OCT o 7 1011 ❑ Revision requested by a City Building Inspector or Plans Examiner ''EFimir corral Project Name: Bergman Luggage Project Address: 102 Southcenter Mall Contact Person: SCOTT RAEDER Summary of Revision: Phone Number: 253 -709 -3485 CORRECTION NOTE #1 REFLECTED ON DRAWING UPPERLEFT HAND CORNER • • • • 1 1 • t • 1 B.. n 1 - - • „ -:= CORRECTION NOTE #3 reflected in main body of drawing CORRECTION #4 THIS SYSTEM IS NOT TIED INTO MALL VENTILATION .FRESH AIR T TAKEN ON ROOF ABOVE UNIT SEE UPPER RICHT HAND SECTION CORRECTION #5 DRAWIB NG SUBMITTED ON @4 x 36 dwg to a scale of 1/4 " =1' Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Entered in Permits Plus on \applications \forms- applications on line\revision submittal Created: 8 -13 -2004 Revised: Contractors or Tradespeopleinter Friendly Page 41 General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name AIRE PRO INC UBI No. 601771753 Phone 2538482626 Status Active Address 2921 Meridian Ave E License No. AIREPI'032RU Suite /Apt. License Type Construction Contractor City Edgewood Effective Date 12/31/1997 State WA Expiration Date 3/18/2012 Zip 98371 Suspend Date County Pierce Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status AIREP "040P4AIRE PRO Construction Contractor Commercial /Industrial /Refri g Air Heat,Ventilation,Evaporat 10/24/1996 10/11/1997 Archived Business Owner Information Name Role Effective Date Expiration Date RAEDER, SCOTT W Chief Executive Officer 12/31/1997 Bond Amount JENNINGS, RICHARD M President 12/31/1997 9360682 KENNETH, BROECK Agent 01/01/1980 06/11/2001 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 4 FEDERATED MUTUAL INS CO 9360682 02/05/2008 Until Cancelled $12,000.0002/14 /2008 3 CBIC SB7063 10/13/2001 02/05/2008 $6,000.0008/01/2001 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 6 FEDERATED SERV /MUT INS CO 9849377 03/11/2007 03/11/2012 $1,000,000.0001 /25/2011 5 FEDERATED MUTUAL INS CO 9849377 03/11/2003 03/11/2007 $1,000,000.00 02/06/2006 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https://fortress.wa.gov/lni/bbip/Print.aspx 10/17/2011 SEPARATE PERMIT REQUIRED FOR: 0 Mothanicai Electrical Plumbing Gas Piping City of Tukwila BUILDING DIVISION TING'CEMENT ROOF SLAB •: . _ 24 GUAGE METAL STRAPS (4) LAGGED INTO CONCRETE AND INTO HEAT PUMP FOR e9NTRoi.., REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NT: r, sv isions will require a new plan submittel c:1 may irdude additional plan rem fen. • MESH MR DUCT • BEAM CLAMPS (4) THREAD .:13/8" ALL T ..„ METAL SLEEVE (R.A.) sPI1I IN EXISTING STEEL ROOF BEAM STEEL I-BEAM 24" DEEP : 10 FEET APART • L•IETAkSI.,,4EyE (S.A.) ROUND RETURN AIR DUCT 20" RND SUPPLY AM DUCT 1 5/8" DEEP CH•NEL', RIP :!AN ! DRIVE CLIP BRACKET, • 375 CFM 104P-10 375 CFM. 104P-10 10,4FLEx 10" FtEX. 1500 CFM 24 X 24 pApj• • 1 6 ' 10"FLEYC 375 CFM 104P-10 • . , 1250 CFM: , 104P-8 !- . 74 !AA ,NA; AtiAN i 375 CFM 104P40 20" iii ROOFTOP MOUNTED HEAT PUMP 16" FLEX. : 6" FLEX I, . - . . - - 125 CFM. :, 104P-6 ALL FLEX DUCT RUN STRAIGHT MAX LENGTH ALL SUPPLY AND RETURN AIR METAL ROUND DUCT INSULATED WITH R-6 WRAP ALL DUCT IS RUN INSIDE OF INSULATED ENVELOPE NORTH 1 5/8" DEEP CHANEL REVIEWED FOR CODE COMPLIANCE APPROVED OCT 1 4 2011 City of BUILDING °IitAJ la ISION FILE COPY Pent* No. NO P52— Mgr review approval is subject to *mom and =Won. At203.oval of construction document does not authete tht v:olation of any adopted code or ordinance. Rece0 of proved Field Copy and conditions is aclmowledpd: By Zitainr, Data: /0 -111 \ City Of Tukwila BUILDING DIVISION ' SCALE: DATE: ciTIABILA OCT 0 7 2011 PERMIT CENTER CORRECTION MIHSZ . BERGMAN LUGGAGE 102 SOUTHCENTER MALL _ TUKWILA, WA. _ _ APPROVED sy : 1/4"=-1' DRAWN BY REVISED MECHANICAL BY AIRE PRO INC. D R AWI NEI NUMBER M-1.