HomeMy WebLinkAboutPermit M11-137 - EDGEWOOD APARTMENTS - UNITS 17, 33 AND 59EDGEWOOD APTS
UNITS 17, 33 & 59
3730 S 148 ST
Mi 1 -137
Parcel No.:
Address:
City oW ukwila
•
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206 - 431 -2451
Web site: http: / /www.TukwilaWA.gov
0040000900
3730 S 148 ST TUKW
MECHANICAL PERMIT
Project Name: EDGEWOOD APTS - UNITS 17, 33 & 59
Permit Number: M11 -137
Issue Date: 10/11/2011
Permit Expires On: 04/08/2012
Owner:
Name:
Address:
Contact Person:
Name:
Address:
Email:
EDGEWOOD APARTMENTS LLC
830 168TH PL SE , BELLEVUE WA 98008
MOHAMMAD AMINPOUR
3730 S 148 ST - OFFICE , TUKWILA WA 98168
Contractor:
Name: OWNER AFFIDAVIT - ARASH AMINPOUR
Address:
Contractor License No:
Phone: 206 - 353 -7857
Phone:
Expiration Date:
DESCRIPTION OF WORK:
ADDING WASHER AND DRYER TO UNITS (STACK OF 3 UNITS). DRYER VENTS AND LAUNDRY
ROOM VENTS
Value of Mechanical: $300.00
Type of Fire Protection: UNKNOWN
Electrical Service Provided by:
Permit Center Authorized Signature:
I hereby certify that I have read and
governing this work will be complied
Fees Collected: $130.31
International Mechanical Code Edition: 2009
Date:
lt� l'Y� Il
ed this permit and know the same to be true and correct. All provisions of law and ordinances
hether specified herein or not.
The granting of this permit does not pre
construction or the performance of work.
back of this permit.
Signature:
to give authority to violate or cancel the provisions of any other state or local laws regulating
I am authorized to sign and obtain this mechanical permit and agree to the conditions on the
Print Name:
Date: L(7 -1 ate.
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
doc: IMC -4/10
M11-137 Printed: 10 -12 -2011
116 •
PERMIT CONDITIONS
Permit No. M11 -137
1: ** *BUILDING DEPARTMENT CONDITIONS * **
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: 1111 mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center
(206/431- 3670).
4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
5: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
6: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be
obtained at City Hall in the office of the City Clerk.
7: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila
Building Department (206- 431 - 3670).
8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206- 431- 3670).
9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
doc: IMC -4/10
M11-137 Printed: 10 -12 -2011
CITY OF TUKW
Community Development Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.TukwilaWA.gov
Mechanical Permit No. M 13 7
Project No.
(For office use only)
MECHANICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *please print **
SITE LOCATION
King Co Assessor's Tax No.:
Site Address: 3730 s. (cfg�"5�rrg-� Suite Number:
Tenant Name: ?/ J II
Property Owners Name: C 1 ea d A.e. (`fit' € -s Lt.." -
Mailing Address: 37 30 s. Net- - S 44,.,0436 C.' ("ty4..t. (Q.
t
Floor:
New Tenant: ❑ Yes ❑..No
Slate
CONTACT PERSON — who do we contact when your permit is ready to be issued
Name: ME, ka ts.a.d „,„ KV", r
Mailing Address:
E -Mail Address: am i' 1460V. CZ C' as, .Let
Day Telephone: (00 s ,78157
State Zip
Fax Number: (y 2s) 5102-- 1 (`47
MECHANICAL CONTRACTOR INFORMATION
Company Name:
Mailing Address:
Contact Person:
E -Mail Address:
Contractor Registration Number:
City
Day Telephone:
Fax Number:
Expiration Date:
State
Zip
ARCHITECT OF RECORD — All plans must be stamped by architect of record
Company Name:
Mailing Address:
Contact Person:
E -Mail Address:
City
Day Telephone:
Fax Number:
State
Zip
ENGINEER OF RECORD — All plans must be stamped by engineer of record
Company Name:
Mailing Address:
City
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
State
Zip
H:\Applications\Portns- Applications On Line\2010 Applications \7 -2010 - Mechanical Penn it Application.doc
Revised: May 2011
bh
Page 1 of 2
o-o
Valuation of project (contractor's bid price): $ 3 p-p
Scope of work (please provide detailed information):
Q cicj J1^ 3 41 d-slar /crY ,) -6o -( - v �: �s 5 +�-f✓ 3 u n; Is
{J 4-s
Use: Residential: New ❑ Replacement ❑
Commercial: New ❑ Replacement ❑
Fuel Type: Electric
Gas ❑
Other:
Indicate type of mechanical work being installed and the quantity below:
Unit Type:
Qty
Unit Type:
Qty
Unit Type:
Qty
Bioler /Compressor
Qty
furnace <100k btu
air handling unit
>10,000 cfrn
fire damper
0 -3 hp /100,000 btu
furnace >100k btu
evaporator cooler
diffuser
3 -15 hp /500,000 btu
floor furnace
ventilation fan connected
to single duct
thermostat
15 -30 hp /1,000,000
btu
suspended/wall/floor
mounted heater
ventilation system
wood/gas stove
30 -50 hp /1,750,000
btu
appliance vent
3
hood and duct
emergency
generator
50+ hp /1,750,000 btu
repair or addition to
heat/refrig/cooling system
Incinerator – domestic
other mechanical
equipment
air handling unit <10,000
cfm
incinerator – comm/ind
PERMIT APPLICATION NOTES -
Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the permit center to comply with current fee schedules.
Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing
and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR AUTHORIZED AGENT:
Signature:
Print Name: tkA#'-
Mailing sk Address: 373 O s.
Date: q�21Ll/
Day Telephone: o 3
w \o i66
(Date Application Accepted: !: ` ` I
%l _ 1
Date Application Expires:
e&,`)_
(c)—
Initials:
H;\Applications\Forms- Applications On Line12010 Applications \7-2010 - Mechanical Permit Application.doc
Revised. May 2011
bh
Page 2 of 2
Cii' of Tukwila. •
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206-431-3665
Web site: http: //www. ci. tukwila. wa. us
SET RECEIPT
Copy Reprinted on 09 -29 -2011 at 15:01:29 09/29/2011
RECEIPT NO: R11 -02141
Initials: JEM
Payment Date: 09/29/2011
User ID: 1165 Total Payment: 2,911.52
Payee: MOHAMMAD A AMINPOUR, EDGEWOOD APARTMENTS LLC
SET ID: S000001585 SET NAME: EDGEWOOD APARTMENTS
SET TRANSACTIONS:
Set Member Amount
D11 -267 63.00
EL11 -0900 63.00
EL11 -0901 63.00
EL11 -0902 63.00
EL11 -0903 63.00
EL11 -0904 63.00
EL11 -0905 63.00
EL11 -0906 63.00
EL11 -0907 63.00
M11 -081 63.00
M11 -135 130.31
M11 -136 130.31
M11 -137 130.31
M11 -138 130.31
M11 -139 130.31
M11 -140 130.31
M11 -141 130.31
M11 -142 130.31
PG11 -142 154.88
PG11 -143 154.88
PG11 -144 154.88
PG11 -145 154.88
PG11 -146 154.88
PG11 -147 154.88
PG11 -148 154.88
PG11 -149 154.88
TOTAL: 63.00
TRANSACTION LIST:
Type Method Description Amount
ACCOUNT ITEM LIST:
Description
Cit.of Tukwila,
•
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206- 431 -3665
Web site: http://wwwci.tukwila.wa.us
TOTAL: 2,911.52
Account Code Current Pmts
ELECTRICAL PERMIT - NONR
MECHANICAL - NONRES
PLAN CHECK - NONRES
PLAN CHECK - RES
PLUMBING - NONRES
000.322.101.00.0
000.322.102.00.0
000.345.830
000.345.830
000.322.103.00.0
TOTAL:
504.00
897.00
456.32
63.00
991.20
2,911.52
# z_
INSPECTION INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 itt_. (206) 431 -3670
Permit Inspection Request Line (206) 431 -2451
37
ProjefA ct: !! (( `l`t�
tP C- �" J
Type In��sp(qectio /�/i ® fl
tr M vi-. ✓ - \ eJ-s,
Address:
11,
Date Called:
Special Instructions:
1-1 33
( 1
�
�
Date Wanted :.
i M 3( -
i` a.m._
/ � p.m.
Requester:
Phone No:
Approved per applicable codes. El Corrections required prior to approval.
COMMENTS:
fk-k7-r--• itAA1OR
r
REINSPECTION FE E ED. rio f to
UIR next inspection. fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.
Insp ctor:
Date:
3
4t(
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
M1( -13*)
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 kz. (206) 431 -3670
Permit Inspection Request Line (206) 431 -2451
Project:
E.oa�t-cJO (5 d App.
Type of Inspection: _ •
0 G tl J-tJ A
Address: Q r71
-- s�
Date Ca ed:
'mil
Special Instructions:
/ 1 3 ?
5 7
Date'VUanted: , Z
2
p.m.
Requester:
Phone No:
Approved per applicable codes. • a Corrections required prior to approval.
COMMENTS:
Ins ector:
Date:
2 23 -(-z
REINSPECTION FEE REQUIRD.. i?rior to next inspection. fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspectioh.
Ins ector:
Date:
2 23 -(-z
REINSPECTION FEE REQUIRD.. i?rior to next inspection. fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspectioh.
r_(.5 Fur 5eb Of e-'C- e WO (04 Al
3930 (4ffm.
GTUN275EM /GM —353 - 78'57
GE® 27" Unitized Spacemaker® 3.4 DOE Cu. Ft. Stainless Steel Washer and 5.9 Cu. Ft. Dryer
Dimensions and Installation Information (in inches)
Electrical Requirements:
GTUN275EM Electric Dryer - This appliance should be connected to an
individual, properly - grounded branch circuit with 120/240V or 120/208V
single -phase 60 Hz electrical service and should be protected by
30 -amp time -delay fuses or circuit breakers KW Rating per voltage
(240/208). This appliance is manufactured with neutral connected to the
frame. Power cord should be purchased separately.
Note:
These appliances are not approved for 120 -volt operation.
Gas Requirements:
GTUN275GM Gas Dryer - This appliance should be connected to an
individual branch circuit with 120 -volt single -phase 60 Hz electrical service
and should be protected by 20 -amp time -day fuses or circuit breakers.
This appliance is equipped with a 4 -foot long flexible U.S. listed 20 -amp
power cord to match a 20 -amp receptacle.
Note:
Gas Rated input 20,000 BTU /HR. Factory equipped for natural gas. Tested
for LP gas. LP gas supply requires a conversion kit. Have a qualified gas
technician install a conversion kit before use.
Dryers must be exhausted to the outside.
Installation Information:
For complete information, see installation instructions packed with
the product.
For answers to your Monogram ® GE Profile' or
GE° appliance questions, visit our website at
geappliances.com or call GE Answer Center°
service, 800.626.2000.
imagination at work
RECEIVED
CITY OF TUKWILA
FEB 062013
PERMIT CENTER
75.5"
52.9'
27.7'
0
«I 00
0
•
Venter P.
'26.7`
18.6"
12.5"
Water inlets
(reorl
[r— 2.9"
Drain outlet
(rear)
3.9"
20.2' —
Gas Inlet
(Rear view of appliance)
3"
u.�
26.8"
1
365"
1
5
•
47"
4.35" --t►
-"ate
30.85 "-- ----►i
Listed by
Underwriters
laboratories
Specification Revised 6/12 360330
l�/1�I -131
ir
c U- 12,177455EM`/GM
a��- ".2 ;7y' Unitized Spacemaker® 3.4 DOE Cu. Ft. Stainless Steel Washer and 5.9 Cu. Ft. Dryer
Dimensions and Installation Information (in inches)
Cilat fitaZ@EViZVIkand--GT-UN-27 E14/ M;pi4
ORKEREEXi:I'At- SrENGHF
For answers to your Monogram ®GE Profile'" or
GE® appliance questions, visit our website at
geappliances.com or call GE Answer Center®
service, 800.626.2000.
Ulf imagination at work
For complete information, see installation instructions packed with your dryer.
Ducting Materials:
For best performance, this dryer should be vented with 4" diameter all rigid metal exhaust duct. If rigid metal
duct cannot be used, then UL- listed flexible metal (semi- rigid) ducting can be used (Kit WX08X100771. In special
installations, it may be necessary to connect the dryer to the house vent using a flexible metal (foil -type( duct.
A UL- listed flexible metal (foil -type) duct may be used ONLY in installations where rigid metal or flexible metal
(semi- rigid) ducting cannot be used AND where a 4" diameter can be maintained throughout the entire length
of the transition duct. Please see installation instruction packed with your dryer for complete instructions when
using flexible metal (foil type) ducting.
Exhaust Length Calculation:
1. Determine the number of 90° turns needed for your installation. If you exhaust to the side or bottom of dryer,
add one turn.
2. The maximum length of 4" rigid (aluminum or galvanized) duct which can be tolerated is shown in the table.
A turn of 45° or less may be ignored. Two 45° turns within the duct length should be treated as a 90° elbow. A turn
over 45° should be treated as a 90° elbow.
Dryers must be exhausted to the outside.
Caution: For personal safety do not terminate exhaust into a chimney, under any enclosed house floor (crawl
space), or into on attic, since the accumulated lint could create a fire hazard or moisture could cause damage.
Never terminate the exhaust into a common duct or plenum with a kitchen exhaust, since the combination of lint
and grease could create a fire hazard.
Exhaust ducts should be terminated in o dampered wall cop to prevent back drafts, bird nesting, etc. The wall cap
must also be located at least 12" above the ground or any other obstruction with the opening pointed down.
Special Installation Requirements
Alcove or Closet Installation:
• If your dryer is approved for installation in an olcove or closet, it will be stated on a label on the dryer back
• The dryer MUST be exhausted to the outside.
• Minimum clearances between dryer cabinet and adjacent walls or other surfaces are
0" either side and rear
1" front and top
• Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 76 -1/2:'
• Closet doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq. in. of open area
equally distributed. If this closet contains both o washer and a dryer, doors must contain a minimum of 120 sq. in.
of open area equally distributed.
• No other fuel- burning appliance shall be installed in the some closet with a gas dryer.
Bathroom or Bedroom Installation:
• The dryer MUST be exhausted to the outdoors.
• The installation must conform with the local codes, or in the absence of local codes, with the National Electric
Code and National Fuel Gas Code, ANSI Z223 for gas dryers.
Minimum Clearances other than Alcove or Closet Installation:
• Minimum clearances to combustible surfaces
0" either side and rear
1" front and top
Listed by
Underwriters
Laboratories
Specification Revised 6/12 360330
RECOMMENDED MAXIMUM LENGTH
Exhaust Hood Types
Recommended
Use only for short
run installations
4" DIA
01313.
4" DIA'I
4"
DIA
!- 12-1/,2
ZKof
Elbow9046. s
Rigid
Metal
Rigid
Metal
0
56 Feet
44 Eeet
42 Feet
3-
2STFeets.
@eet
24 o f
ee
For answers to your Monogram ®GE Profile'" or
GE® appliance questions, visit our website at
geappliances.com or call GE Answer Center®
service, 800.626.2000.
Ulf imagination at work
For complete information, see installation instructions packed with your dryer.
Ducting Materials:
For best performance, this dryer should be vented with 4" diameter all rigid metal exhaust duct. If rigid metal
duct cannot be used, then UL- listed flexible metal (semi- rigid) ducting can be used (Kit WX08X100771. In special
installations, it may be necessary to connect the dryer to the house vent using a flexible metal (foil -type( duct.
A UL- listed flexible metal (foil -type) duct may be used ONLY in installations where rigid metal or flexible metal
(semi- rigid) ducting cannot be used AND where a 4" diameter can be maintained throughout the entire length
of the transition duct. Please see installation instruction packed with your dryer for complete instructions when
using flexible metal (foil type) ducting.
Exhaust Length Calculation:
1. Determine the number of 90° turns needed for your installation. If you exhaust to the side or bottom of dryer,
add one turn.
2. The maximum length of 4" rigid (aluminum or galvanized) duct which can be tolerated is shown in the table.
A turn of 45° or less may be ignored. Two 45° turns within the duct length should be treated as a 90° elbow. A turn
over 45° should be treated as a 90° elbow.
Dryers must be exhausted to the outside.
Caution: For personal safety do not terminate exhaust into a chimney, under any enclosed house floor (crawl
space), or into on attic, since the accumulated lint could create a fire hazard or moisture could cause damage.
Never terminate the exhaust into a common duct or plenum with a kitchen exhaust, since the combination of lint
and grease could create a fire hazard.
Exhaust ducts should be terminated in o dampered wall cop to prevent back drafts, bird nesting, etc. The wall cap
must also be located at least 12" above the ground or any other obstruction with the opening pointed down.
Special Installation Requirements
Alcove or Closet Installation:
• If your dryer is approved for installation in an olcove or closet, it will be stated on a label on the dryer back
• The dryer MUST be exhausted to the outside.
• Minimum clearances between dryer cabinet and adjacent walls or other surfaces are
0" either side and rear
1" front and top
• Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 76 -1/2:'
• Closet doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq. in. of open area
equally distributed. If this closet contains both o washer and a dryer, doors must contain a minimum of 120 sq. in.
of open area equally distributed.
• No other fuel- burning appliance shall be installed in the some closet with a gas dryer.
Bathroom or Bedroom Installation:
• The dryer MUST be exhausted to the outdoors.
• The installation must conform with the local codes, or in the absence of local codes, with the National Electric
Code and National Fuel Gas Code, ANSI Z223 for gas dryers.
Minimum Clearances other than Alcove or Closet Installation:
• Minimum clearances to combustible surfaces
0" either side and rear
1" front and top
Listed by
Underwriters
Laboratories
Specification Revised 6/12 360330
•r
GTUN275EM /GM
GE® 27" Unitized Spacemaker® 3.4 DOE Cu. Ft. Stainless Steel Washer and 5.9 Cu. Ft. Dryer
Features and Benefits
• 3 wash /spin speed combinations - Speeds are matched to fabric type
for great clothes care
• 9 wash cycles - Cycles are designed to specifically handle various
fabrics and soils
• Auto -load sensing with 5 water levels - Washer will automatically
measure the load size and add just the right amount of water
• Bleach and fabric softener dispensers - Solutions are automatically
mixed with wash water for clean, bright, soft -to- the -touch results
• Rotary - electronic controls (washer) - Simplify cycle selection
• Cycle status lights - Provide accurate cycle times
• Rotary - electromechanical controls (dryer) - Allow fast, easy cycle
selection
• Stainless steel washer basket - Long - lasting stainless steel finish
resists rust and won't chip, peel or snag clothes
• Model GTUN275EMWW - White on white (Electric)
• Model GTUN275GMWW - White on white (Gas)
imagination at work
Modified Energy Factor (MEF)
2.02
Water Factor (WF)
5.65
\I I
ENERGY STAR
As an ENERGY STAR®
partner, GE has determined
that this product meets the
ENERGY STAR guidelines
tor energy efficiency.
Specification Revised 6/12 360330
SEPARATE PE RMiT
REQUIRED FOR:
❑ Mechanical
Electrical
Plumbing
Gas Piping
City of Tukwila
BUILDING DIVISION
PROJECT INFORMATION
Parcel Number
004000 -0900
Name
EDGEWOOD APARTMENTS LLC
Site Address
3730 S 148TH ST 98168
Legal
ADAMS HOME TRS POR OF S 30 FT OF LOTS 10 & 11 &
W 1/2 OF LOT 23 & ALL OF LOT 24 & POR OF LOTS 25 &
26 LESS POR SD LOTS 10 & 25 & 26 LY WLY & NLY OF
FOLG DESC LINES - BAAP ON N LN OF S 30 FT OF SD
LOT 10 LY 120 FT ELY OF PACIFIC HWY S TH S PLW SD
HWY 200 FT TH W PLW N LN SD LOTS 25 & 26 TO ELY
MGN OF SD HWY & TERMINUS OF LN DESC LESS E 88
FT OF SD LOT 11 LESSS 10 FT OF SDLOT24 &OFW
1/2 OF LOT 23 LESS RD
REVIEWED FOR
CODE COMPLIANCE
APPROVED
OCT 0 7 2011
ila
VISION
City of
BUILDING
CONTACT/OWNER
MOHAMMAD AMINPOUR
425 - 502 -9146
3730 S 148TH ST
TUKWILLA, WA 98168
TABLE OF' CONTENTS
A1.1 SITE PLAN
A2.1
A2,2
A3.1
A3.2
TYPICAL UNIT PLAN
PARTIAL FLOOR PLAN
DETAILS
RISER DIAGRAM
A4.0 DRYER SPEC.
/
S 146th St 99
I
S 148th
SITE
St X
1
I
VICINITY MAP
FILE COPY
Pennii
Plan ,. eview approaPai is Oct to eff011 and omens.
Approval of construction documents does not altloi s
the violation of any adopted code or ordinance, ReC Pt
of approved Raid Copy and conditions is acknowledged:
BY
City Of lbkwif
BUILDING DIVISI ON
Washer /Dryer Addition
Edgewood Apartments
9 -27 -2011 3730 S 148th St. Tukwilla WA 98168
REVISIONS
No changes shall be made to the ecope
of work without prior approve! of
Tukwila Building Division.
NOTE: Revisions will require a new plan submittal
and may include additional plan review fees.
A0.0
RECEIVED
SEP 2 9 2011
PERMITCENTER
EXIST
PARKING
A(do(�-
�,;
1%7A) 59
S- 14&TI -1 ST
SITE PLAN
i'= 50' -0'
N
REVIEWED F p
CODE COMPLIANCE
APPROVED
OCT 072011
8U1�City Tukwila
i
IVISIpN
Washer / Dryer Addition
Edgewood Apartments
9 -27 -11 3730 S 1 48th St. Tukwilla WA 98168
RECEIVED
SEP 29 2011
PERMIT CENTER
A1.1
1/2" HW-
1/2" CW'
Living
EXISTING CONSTRUCTION
NEW WALL
NEW
W/D
HW
Hall
ELECTRIC PANEL -
Br l
Deck
Nook
l�
Kit
50 CFM MIN WALL MOUNT FAN
VENT TO EXTERIOR
Br 2
4 "" DRYER DUCT
3 "" VENT DUCT IN
NEW SOFFIT
DISCHARGE 36"
FROM ANY
OPERABLE
OPENING
DUCT LENGTH
NOT TO EXCEED 33' (3 EL
ALLOWABLE PER
W/D MFG
3'
0 "MIN
Typical Apartment Unit
Scale: 1 /4" = 1' -0"
Washer / Dryer Addition
Edgewood Apartments
9 -27- 2011 3730 S 148th St. Tukwilla WA 98168
REVIEWED FOR
CODE COMPLIANCE
APPROVED
OCT 0 7 2011
City of Tukwila
UILDING DIVISION
WS MAX)
A2.1
RECEIVED
SEP 2 9 2011
PERMIT CENTER
NOTE: All plumbing penetrations shall be fire stopped per code such that the required fire resistance shall not be reduced.
TO SIDE SEWER
N
Typical Partial Plumbing Plan IT
Scale: 1" = 10 ft
Washer /Dryer Addition
Edgewood Apartments
9 -27-11 3730 S 148th St. Tukwilla WA 98168
LEGEND
NEW
EXISTING - - - - -
RCO,pE CQWED FOR
ROVED
OCT 0 7 2011
City of Tukwila
BUILDING DIVISION
A2.2
RECEIVED
SEP 2 9 2011
PERMIT CENTEF
FLOOR
.//AI11JIl rI111111 rI11F1 • irAlFA F:1 #I-j%I:/:I1'Illl:I:I11:I1:I:I'
CEILING
SECTION
8' -9" MIN
5/8" TYPE 'X' GWB
FIELD VERIFY ADEQUATE AREA FOR ALL DUCTS AND CROSSES
TO BE INSTALLED
Note: continuous 5/8" type x gwb above
dropped ceiling /chase and @ unit separation wall
1 Hr Chase
1 Scale: 1" = 1' -0"
REVIEWED FOR
CODE COMPLIANCE
APPROVED
OCT 0 7 2011
City of Tukwila
BUILDING DIVISION
Edgewood Apartments
9- 27-11 3730 S 148th St. Tukwilla WA 98168
ECESVED
SEP 29 2011
PERMIT CENTER
A3.1
ROOF
2 "V -♦"'
1 1 / 2" Vi'"
THIRD FLOOR
11 /2 "Vim-
SECOND FLOOR
11/2 "V
FIRST FLOOR
2" W
NEW 3" W
CRAWL SPACE
k-1 1/2" V
-2" W
2" W
CO
EXISTING 4" 1
Riser Diagram
Washer /Dryer Addition
Edgewood Apartments
9- 27-11 3730 S 148th St. Tukwilla WA 98168
REVIEWED FOR
CODE COMPLIANCE
APPROVED
OCT 0 7 2011
City of Tukwila
BUILDING DIVISION
A3.2
RECEIVE)
SEP 29 2011
PERMIT CENTEF
iripool
PRODUCT MODEL NUMBERS
Electrical This dryer requires a 3 or 4 wire, single
phase, 120/240 volt, 60 Hz, AC only electrical supply
(or 3 or 4 wire, 120/208 volt electrical supply, if
specified on the serial /rating plate) on a separate
30 -amp circuit, fused on both sides of the Tine.
Connect to an individual branch circuit. Do not have
a fuse in the neutral or grounding circuit.
Exhaust venting Exhaust your dryer to the outside.
4" (1 02 mm) diameter vent is required. Rigid or flexible
metal exhaust vent must be used. Do not use plastic
or metal foil vet. Exhaust hood must be at least
12" (305 mm) from the ground or any object that
may be in the path of the exhaust.
Hood styles A & B are recommended.
Q 4"
(102 mm)
•
(102 mm)
(102 mm)
\,k.4%, 212,
(64 mm)
A. Louvered hood
B. Box hood
C. Angled hood (acceptable)
The Vent system chart provides venting requirements
that will heip achieve best drying performance.
NOTE: Side and bottom exhaust installation have a 90"
turn inside the dryer. To determine maximum exhaust
length, add one 90' turn to the chart.
vent system taldrl
Number of
90` elbows
Type
of vent
Box /louvered
hoods
Angled $d'
hoods
0
Rigid metal
64 ft (20 m)
58 ft.
1
Rigid metal
54 ft. (16.5 m)
48 ft.
2
Rigid metal
44 ft. (13.4 m)
38 tt.
3
Rigid metal
35 ft. (10.7 m)
29 ft. (8.8 m)
4
Rigid metal
27 ft (8.2 m)
21 ft (b 4 m)f
Do not use vent runs longer than specified in vent
length chart.
Determine the number of elbows you will need.
Select the route that will provide the straightest and
most direct path outdoors.
Plan the installation to use the fewest number of
elbows and turns.
Use the fewest 90" turns possible.
Electric Dryer
Dryer dimensions
+r - -_ 7,.
O f6 .nn5
1 1/2x- -d
4
RS.")
OVERALL DIMENSIONS
Minimum Required Spacing
•
d,•.•
i174 11,11,1
r
• (4, 1110,
6'
(152 mm)
f -t
f
I;I (76 mmll 1
;11' 48 tn.'
76" I (310 cm')
(1030 mm)
4"
(102 mm)\
For closet installation, with a door,
the minimum ventilation openings
in the top and bottom of the door
are required. Louvered doors with
equivalent air ventilation openings
are acceptable.
Most installations require a
minimum 5" (127 mm) clearance
behind the dryer for the exhaust
vent with elbow. See "Venting
Requirements."
(25 mm)
(102 trim) "
1"
(25 mm)
34" recommended
(664 mm)
18' min.
(457 mm)
s:
1 24 in..
I; (155 cm')
3" j
(76 mm)
3 "I
(76 mm) t
48 m.'
(310 cm')
v�.
24 In.'
! (155 cm')
(76 unm)
1
(25 mm) }'
- (25 mm)
Because Whirlpool Corporation policy includes a continuous commitment to improvo
till' plO[h1Cij Wd reser vt the light to CI{dngb I {Itilel {dry dell lip iCl rl,. 11l0 l$ w.tllout 110t1:C.
Dimensions aro for planning purposes only. For complete details, see Installation
Instruciiuus packbd w.th pru,JUCt. Sueonuatior s jubiul;t to change without nuTICe.
-=}' ECE1VED
SEP 2 9 2011
Ref MDR CENTER
11.2010
A"1.o
01 -02 -2013
City of f Tukwila
Jim Haggerton, Mayor
Department of Community Development Jack Pace, Director
MOHAMMAD AMINPOUR
3730 S 148 ST - OFFICE
TUKWILA WA 98168
RE: Permit No. M11 -137
EDGEWOOD APTS - UNITS 17, 33 & 59
3730 S 148 ST TUKW
Dear Permit Holder:
In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building
Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National
Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and
become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date
of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has
begun for a period of 180 days. Your permit will expire on 02/18/2013.
Based on the above, you are hereby advised to:
1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection.
Each inspection creates a new 180 day period, provided the inspection shows progress.
-or-
2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to
expire. Address your extension request to the Building Official and state your reason(s) for the need to extend
your permit.
The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your
extension request is granted, you will be notified by mail.
In the event you do not call for an inspection and/or receive an extension prior to 02/18/2013, your permit will become null
and void and any further work on the project will require a new permit and associated fees.
Thank you for your cooperation in this matter.
Sincerely,
c
Bill Rambo
Permit Technician
File: Permit File No. M I 1 -137
6300 Southceiater Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206-431 -3670 • Fax 206- 431 -3665
City of Tukwila
Jim Haggerton, Mayor
Department of Community Development Jack Pace, Director
August 22, 2012
Mohammad Aminpour
Manager, Edgewood Apartments
3730 S 148 Street
Tukwila, WA 98168
RE: Request for Extensions
Edgewood Apartments
Dear Mr. Aminpour,
This letter is in response to your written request for an extension to multiple permits. The
Building Official, Bob Benedicto, has reviewed your letter and considered your request to extend
the permits. The City of Tukwila Building Division will be extending your permits an additional
180 days from the date of expiration as shown below:
New expiration date of February 18, 2013
M11 -081, MI 1 -136, M11 -137, M11 -138
PG11 -083, PG11 -143, PG11 -144, PG11 -145
New expiration date of March 21, 2013
M11 -135, M11 -139, M11 -140, M11 -141, M11 -142, M12 -001 through M12 -007
PG 11 -142, PG 12 -002 through PG 12 -008
If you should have any questions, please contact our office at (206) 431 -3670.
Sincerely,
W:\Permit Center\Extension Letters \Permits\2011\M11 -081 Permit Extension.doc
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665
EDGEWOOD APARTMENTS
3730 South 148th Street
Tukwila, WA 98168
(206) 246 -3269
August 15, 2012
Mr. William Rambo
City of Tukwila
Department of Community Development
6300 Southcenter Blvd., Suite #100
Tukwila, WA 98188
Dear Mr. Rambo,
The primary work for the following permits has been completed but we still need to do some
final requirements in order to get final inspection approvaL Therefore, I am requesting for
extension of time to complete the final work requirements for these permits.
Mechanical permit numbers are as follows:
M11 -081, M11 -136, M11 -137, M11 -138: expiration date 8 -21 -12
M11 -135, M11 -139, M11 -140, M11 -141, M11 -142, M12 -0O1, M12 -002, M12 -003, M12 -004,
M12 -005, M12 -006, M12 -007: expiration date 9 -22 -12
Pluming permit numbers are as follows:
PG11 -083, PG11 -143, PG11 -144, PG11 -145: expiration date 8 -21 -12
PG11 -142, PG12 -002, PG12 -003, PG12 -004, PG12 -006, PG12 -007, PG12 -008: expiration
date 9 -22 -12 1)G I?---005
I would like to thank you in advance for your kind consideration of this matter. Please feel
free to contact me at (206) 353 -7857 if you need further information or explanation.
Sincerely,
olfammad Aminpour, Manager, Edgewood Apartments, LLC RECEIVED
of`:Y OF TUKWILA
AUG 15 20121
t� d4!d
-ev,pkci4 ;ea dovd,
8 /u /20 /z
PERMIT CENTER
t$I1A) 4- ° Q2 14 13
tot 1) t\4 -1' 01211113
EDGEWOOD APARTMENTS
3730 South 148th Street
Tukwila, WA 98168
(206) 246 -3269
August 15, 2012
Mr. William Rambo
City of Tukwila
Department of Community Development
6300 Southcenter Blvd., Suite #100
Tukwila, WA 98188
Dear Mr. Rambo,
The primary work for the following permits has been completed but we still need to do some
final requirements in order to get final inspection approval. Therefore, I am requesting for
extension of time to complete the fmal work requirements for these permits.
Mechanical permit numbers are as follows:
M11 -081, M11 -136, M11 -137, M11 -138: expiration date 8 -21 -12
M11 -135, M11 -139, M11 -140, M11 -141, M11 -142, M12 -001, M12 -002, M12 -003, M12 -004,
M12 -005, M12 -006, M12 -007: expiration date 9 -22 -12
Pluming permit numbers are as follows:
PG11 -083, PG11 -143, PG11 -144, PG11 -145: expiration date 8 -21 -12
PG11 -142, PG12 -002, PG12 -003, PG12 -004, PG12 -006, PG12 -007, PG12 -008: expiration
date 9 -22 -12 ?G I? --005
I would like to thank you in advance for your kind consideration of this matter. Please feel
free to contact me at (206) 353 -7857 if you need further information or explanation.
Sincerely,
ammad Aminpour, Manager, Edgewood Apartments, LLC
RECEIVED
eirf OF TUKWILA
AUG 15 20121
PERMIT CENTER
07 -02 -2012
City of Tukwila Jim Haggerton, Mayor
Department of Community Development Jack Pace, Director
MOHAMMAD AMINPOUR
3730 S 148 ST - OFFICE
TUKWILA WA 98168
RE: Permit No. M11 -137
EDGEWOOD APTS - UNITS 17, 33 & 59
3730 S 148 ST TUKW
Dear Permit Holder:
In reviewing our current records, the above noted permit has not received a fmal inspection by the City of Tukwila Building
Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National
Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and
become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date
of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has
begun for a period of 180 days. Your permit will expire on 08/21/2012.
Based on the above, you are hereby advised to:
1) Call the City of Tukwila Inspection Request Line at 206 -431 -2451 to schedule for the next or fmal inspection.
Each inspection creates a new 180 day period, provided the inspection shows progress.
-or-
2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to
expire. Address your extension request to the Building Official and state your reason(s) for the need to extend
your permit.
The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your
extension request is granted, you will be notified by mail.
In the event you do not call for an inspection and/or receive an extension prior to 08/21/2012, your permit will become null
and void and any further work on the project will require a new permit and associated fees.
Thank you for your cooperation in this matter.
Sincerely,
Bill Rambo
Permit Technician
File: Permit File No. Ml 1 -137
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206 -431 -3670 • Fax 206 - 431 -3665
Y •
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: M11 -137
DATE: 09 -29 -11
PROJECT NAME: EDGEWOOD APTS - UNITS 17, 33 & 59
SITE ADDRESS: 3730 S 148 ST
X Original Plan Submittal
Response to Correction Letter #
Response to Incomplete Letter #
Revision # After Permit Issued
DEPARTMENTS:
Bur ilcing Division
Public Works
Fire Prevention
Structural
Planning Division
n Permit Coordinator
DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 10 -04 -11
Complete IRt Incomplete ❑ Not Applicable ❑
Comments:
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES/THURS ROUTING:
Please Route
Structural Review Required
REVIEWER'S INITIALS:
No further Review Required
DATE:
APPROVALS OR CORRECTIONS:
DUE DATE: 11 -01 -11
Approved ❑ Approved with Conditions ii Not Approved (attach comments) ❑
Notation:
REVIEWER'S INITIALS: DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents /routing slip_doc
2 -28 -02
•
CITY OF TUKWILA
Department of Community Development
6300 Southcenter Boulevard, Tukwila, WA 98188
Telephone: (206) 431-367o FAX (206) 431 -3665
E -mail: tukplanc ci.tukwila.wa.us
Permit Center /Building Division
206 431 -3670
Public Works Department
206 433-0179
Planning Division
206 431 -3670
AFFIDAVIT IN LIEU OF CONTRACTOR REGISTRATION
STATE OF WASHINGTON)
) ss.
COUNTY OF KING )
Ar0,41. ,4 • v . ot.`r , states as follows:
[please print name]
.ERMR NO: EUI-orIN
MCI - IH2 -�
?--- L2It
1. -I have made application for a permit from the City of Tukwila, Washington.
2. I understand that state law requires that all building construction contractors be registered with the
State of Washington. The exceptions to this requirement are stated under Section 18.27.090 of the
Revised Code of Washington, a copy of which is printed on the reverse side of this Affidavit. I have
read or am familiar with RCW 18.27.090.
3. I understand that prior to issuance of a permit for work which is to be done by any contractor, the
City of Tukwila must verify either that the contractor is registered by the State of Washington, or that
one of the exemptions stated under RCW 18.27.090 applies.
4. In order to provide verification to the City of Tukwila of my compliance with this requirement, I
hereby attest that after reading the exemptions from the registration requirement of RCW 18.27.090,
I consider the work authorized under this permit to be exempt under number j .., and will therefore
not be performed by a registered contractor.
5. I understand that the licensing provision of RCW 19.28.161 through 19.28.271 shall not apply to
persons making electrical installations on their own property or to regularly employed employees
working on the premises of their employer. The proposed electrical work is not for the construction
of a new building for rent, sale or lease.
I understand that I may be waiving certain rights that I might otherwise have under state law in any decision
to engage an unregistered contractor to perform construction work.
Signed and sworn to before me this
r day of Semi,C'/'
Y PUBLIC in and,for the State of Washington
Residing at /1 inn County
(J ,
Name as commissioned: fa-e-(14 /f t , 7l e-.
My commission expires: �S o� 9 '� V
18.27.OQO Exemptions. The regis tion provisions of this chapter do not apply t•
1. An authorized representative of t
nited States
government, the state of Washington, or any incorporated
city, town, county, township, irrigation district, reclamation
district, or other municipal or political corporation or
subdivision of this state;
2. Officers of a court when they are acting within the scope
of their office;
3. Public utilities operating under the regulations of the
utilities and transportation commission in construction,
maintenance, or development work incidental to their own
business;
4. Any construction, repair, or operation incidental to the
discovering or producing of petroleum or gas, or the
drilling, testing, abandoning, or other operation of any
petroleum or gas well or any surface or underground mine
or mineral deposit when performed by an owner or lessee;
5. The sale of any finished products, materials, or articles of
merchandise that are not fabricated into and do not become
a part of a structure under the common law of fixtures;
6. Any construction, alteration, improvement, or repair of
personal property performed by the registered or legal
owner, or by a mobile /manufactured home retail dealer or
manufacturer licensed under chapter 46.70 RCW who shall
warranty service and repairs under chapter 46.70 RCW;
7. Any construction, alteration, improvement, or repair
carried on within the limits and boundaries of any site or
reservation under the legal jurisdiction of the federal
government;
8. Any person who only furnished materials, supplies, or
equipment without fabricating them into, or consuming
them in the performance of, the work of the contractor;
9. Any work or operation on one undertaking or project by
one or more contracts, the aggregate contract price of
which for labor and materials and all other items is less
than five hundred dollars, such work or operations being
considered as of a casual, minor, or inconsequential nature.
The exemption prescribed in this subsection does not apply
in any instance wherein the work or construction is only a
part of a larger or major operation, whether undertaken by
the same or a different contractor, or in which a division of
the operation is made into contracts of amounts less than
five hundred dollars for the purpose of evasion of this
chapter or otherwise. The exemption prescribed in this
subsection does not apply to a person who advertises or
puts out any sign or card or other device which might
indicate to the public that he or she is a contractor, or that
he or she is qualified to engage in the business of
contractor,
10. Any construction or operation incidental to the
construction and repair of irrigation and drainage ditches
of regularly constituted irrigation districts or reclamation
districts; or to farming, dairying, agriculture, viticulture,
horticulture, or stock or poultry raising; or to clearing or
other work upon land in rural districts for fire prevention
purposes; except when any of the above work is performed
by a registered co actor;
11. An owner* who contracts for a project with a registered
contractor, except that this exemption shall not deprive . the
owner of the protections of this chapter against registered
and unregistered contractors. The exemption prescribed in
this subsection does not apply to a person who performs
the activities of a contractor for the purpose of leasing or
selling improved property he or she has owned for less than
twelve months;
12.* Any person working on his or her own property,
whether occupied by him or her or not, and any person
working on his or her personal residence, whether owned
by him or her or not but this exemption shall not apply to
any person who performs the activities of a contractor on
his or her own property for the purpose of selling,
demolishing, or leasing the property;
13. An owner* who performs maintenance, repair, and
alteration work in or upon his or her own properties, or
who uses his or her own employees to do such work;
14. A licensed architect or civil or professional engineer
acting solely in his or her professional capacity, an
electrician certified under the laws of the state of
Washington, or a plumber certified under the laws of the
state of Washington or licensed by a political subdivision of
the state of Washington while operating within the
boundaries of such political subdivision. The exemption
provided in this subsection is applicable only when the
person certified is operating within the scope of his or her
certification;
15. Any person who engages in the activities herein
regulated as an employee of a registered contractor with
wages as his or her sole compensation or as an employee
with wages as his or her sole compensation;
16. Contractors on highway projects who have been
prequalified as required by RCW 47.28.070, with the
department of transportation to perform highway
construction, reconstruction, or maintenance work;
17. A mobile /manufactured home dealer or manufacturer
who subcontracts the installation, set -up, or repair work to
actively registered contractors. This exemption only applies
to the installation, set -up, or repair of the
mobile /manufactured homes that were manufactured or
sold by the mobile /manufactured home dealer or
manufacturer;
18. An entity who holds a valid'el'ectrical.contractor's
license under chapter 19.28 RCW;th4einploys a certified
journeyman electrician, a,certified'•resldeatial specialty
electrician, or an electrieaktrainee meeting the
requirements of chapter i9:28 RCW to perform plumbing
work that is incidentally,;directly, and immediately
appropriate to the like -in -kind replacement'oti household
appliance or other small household utilization'equipment
that requires limited electric dower and ;limited waste
i r Sit.
and /or water connections.tjn`- . cal trainee must be
supervised by a certified electrician while performing
plumbing work.
• Per Washington State Department of Labor and Industries, lessee has been
interpreted to be equivalent to owner for the purpose of these exemptions.