HomeMy WebLinkAboutPermit M11-141 - EDGEWOOD APARTMENTS - UNITS 12, 28 AND 54EDGEWOOD APTS
UNITS 12, 28 & 54
3730 S 148 ST
Mi 1 -141
City Tukwila
•
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206 - 431 -2451
Web site: http: / /www.TukwilaWA.gov
MECHANICAL PERMIT
Parcel No.: 0040000900
Address: 3730 S 148 ST TUKW
Project Name: EDGEWOOD APTS - UNITS 12, 28 & 54
Permit Number: M11 -141
Issue Date: 10/12/2011
Permit Expires On: 04/09/2012
Owner:
Name: EDGEWOOD APARTMENTS LLC
Address: 830 168TH PL SE , BELLEVUE WA 98008
Contact Person:
Name: MOHAMMAD AMINPOUR Phone: 206 - 353 -7857
Address: 3730 S 148 ST - OFFICE , TUKVVILA WA 98168
Email:
Contractor:
Name: OWNER AFFIDAVIT - ARASH AMINPOUR Phone:
Address:
Contractor License No: Expiration Date:
DESCRIPTION OF WORK:
ADDING WASHER AND DRYER TO UNITS (STACK OF 3 UNITS). DRYER VENTS AND LAUNDRY
ROOM VENTS
Value of Mechanical: $300.00
Type of Fire Protection: UNKNOWN
Electrical Service Provided by:
Permit Center Authorized Signature:
Fees Collected: $130.31
International Mechanical Code Edition: 2009
Date: 101 1/4 -
I hereby certify that I have read and ex =d this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied th, ether specified herein or not.
The granting of this permit does not pres to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the
back of this permit.
Signature:
Print Name:
Date: fln —��- -�
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
doc: IMC -4/10
M11 -141
Printed: 10 -12 -2011
PERMIT CONDITIONS
Permit No. M11-141
1: ** *BUILDING DEPARTMENT CONDITIONS * **
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center
(206/431- 3670).
4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
5: All construction shall be done m conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
6: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be
obtained at City Hall in the office of the City Clerk.
7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila
Building Department (206- 431 - 3670).
9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206- 431- 3670).
doc: IMC -4/10
M11 -141 Printed: 10 -12 -2011
CITY OF TUKWI
Community Development Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.TukwilaWA.gov
•
Mechanical Permit No. M ((.. (u 1
Project No.
(For office use only)
MECHANICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *please print **
SITE LOCATION
Site Address: 3730 S. (clg" 50.4'eA.,
Tenant Name: 19-, 3 5-1
Property Owners Name: c4j op J h. 4rs LIJ .
Mailing Address: 3730 se 19pr- g A - - Ghtt . C t (a,
1ty
King Co Assessor's Tax No.:
Suite Number: Floor:
New Tenant: ❑ Yes ❑ .. No
4.1
CONTACT PERSON — who do we contact when your permit is ready to be issued
Name: MfjLaww.&d Anne920r
Mailing Address:
E -Mail Address: am i w 16vr (Z CO ••,. c( . 's et
Day Telephone: (206) 353-7C5-7
State Zip
Fax Number: (y 2s-) 5f)2.— (Lk 7
MECHANICAL CONTRACTOR INFORMATION
Company Name:
Mailing Address:
City
Day Telephone:
Fax Number:
Expiration Date:
Contact Person:
E -Mail Address:
Contractor Registration Number:
State
Zip
ARCHITECT OF RECORD — All plans must be stamped by architect of record
Company Name:
Mailing Address:
City
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
State
Zip
ENGINEER OF RECORD — All plans must be stamped by engineer of record
Company Name:
Mailing Address:
City
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
State
Zip
H:\Applications\Forms- Applications On Line\2010 Applications \7 -2010 - Mechanical Permit Application.doc
Revised: May 2011
bh
Page 1 of 2
o-o
Valuation of project (contractor's bid price): $ 3 490
Scope of work (please provide detailed information):
ljat_s l y -6o - - •■((� Cc -
Lryer 4 k v.�� �•_ V.eA r}S
Use: Residential: New ❑ Replacement ❑
Commercial: New ❑ Replacement ❑
Fuel Type: Electric Gas ❑ Other:
Indicate type of mechanical work being installed and the quantity below:
Unit Type:
Qty
Unit Type:
Qty
Unit Type:
Qty
Bioler /Compressor
Qty
furnace <100k btu
air handling unit
>10,000 cfm
fire damper
0 -3 hp /100,000 btu
furnace >100k btu
evaporator cooler
diffuser
3 -15 hp /500,000 btu
floor furnace
ventilation fan connected
to single duct
2
✓
thermostat
15 -30 hp /1,000,000
btu
suspended/wall/floor
mounted heater
ventilation system
wood/gas stove
30 -50 hp /1,750,000
btu
appliance vent
3
hood and duct
emergency
generator
50+ hp /1,750,000 btu
repair or addition to
P
heat/refrig/cooling system
Incinerator - domestic
other mechanical
equipment
air handling unit <10,000
cftn
incinerator - comm/ind
PERMIT APPLICATION NOTES -
Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the permit center to comply with current fee schedules.
Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing
and justifiable cause demonstrated. Section 105.3.2 Intemational Building Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR AUTHORIZED AGENT:
Signature:
Print Name: 6 Q w. w t....etror
Mailing Address: 373 O �' f le—S`
—
Day Telephone:
Thu` )a
Date: / —
W 3t�te q8'�6 6
IDate Application Accepted:
q,)01_ C (
Date Application Expires:
?, f _ ��
Staff Initials:
H: 1Applications\Ponns- Applications On Line12010 Applications17 -2010 - Mechanical Permit Application.doc
Revised: May 2011
bh
Page 2 of 2
Citi of Tukwila. •
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206-431-3665
Web site: httn: /hvww. ci. tukwila. wa. us
SET RECEIPT
Copy Reprinted on 09 -29 -2011 at 15:01:29 09/29/2011
RECEIPT NO: R11 -02141
Initials: JEM
User ID: 1165
Payment Date: 09/29/2011
Total Payment: 2,911.52
Payee: MOHAMMAD A AMINPOUR, EDGEWOOD APARTMENTS LLC
SET ID: S000001585 SET NAME: EDGEWOOD APARTMENTS
SET TRANSACTIONS:
Set Member Amount
D11 -267 63.00
EL11 -0900 63.00
EL11 -0901 63.00
EL11 -0902 63.00
EL11 -0903 63.00
EL11 -0904 63.00
EL11 -0905 63.00
EL11 -0906 63.00
EL11 -0907 63.00
M11 -081 63.00
M11 -135 130.31
M11 -136 130.31
M11 -137 130.31
M11 -138 130.31
M11 -139 130.31
M11 -140 130.31
M11 -141 130.31
M11 -142 130.31
PG11 -142 154.88
PG11 -143 154.88
PG11 -144 154.88
PG11 -145 154.88
PG11 -146 154.88
PG11 -147 154.88
PG11 -148 154.88
PG11 -149 154.88
TOTAL: 63.00
TRANSACTION LIST:
Type Method Description Amount
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 L2 (206) 431 -367
Permit Inspection Request Li,�e (206) 431 -2451
Projecj J G W U J
TYP� I ( i n�I
Me
f
'
"'
Add�esc.73 J
y
r,T
Date Called:
(
Special Instructions:
! 2
L� �
...
` C I
CI
Date Wanted:. _�
/
f --- rxr.
3 p.m.
Requester:
Phone No:
Approved per applicable codes. El Corrections required prior to approval.
COMMENTS:
rel r L.0 it, ote,fp
i
Insiector:
it
t
Date: ( _ 1,3
❑ REINSPECTION FEE REQU 'ED. Prior to next inspection. fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.
J� INSPECTION RECORD
Retain a copy with permit /77// -/4'/
INSPEC ION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188, (206) 431 -3670
Permit Inspection Request Line (206) 431 -2451
Project:
F,bru t9P 7 - S
Type of Inspection:
--1 = -; = -
- =
y°
Address:
3d S 1 vcq S7
Date Call - •,
%0
,17-7
Special Instructions:
2/ /7' /2 '..? "? -V S/
Date Want - • :.
a.m.
Requester:
Phone No:
,„.7e)6 -3i 3
:71_5-7
•
Approved per applicable codes. Corrections required prior to approval.:
COMMENTS:
II A biti-i(
o
pt-
Inspect�r:
Date: — C 1,
n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspectioh.
.`
For- n (� 5t1P 01-7 , O T r @___--a06U[0(o 6 v_Ats-
330 (- R'
GTUN275EM /GM ,;- ,� _353 r 78/57
GE® 27" Unitized Spacemaker® 3.4 DOE Cu. Ft. Stainless Steel Washer and 5.9 Cu. Ft. Dryer
Dimensions and Installation Information (in inches)
Electrical Requirements:
GTUN275EM Electric Dryer - This appliance should be connected to an
individual, properly - grounded branch circuit with 120/240V or 120/208V
single -phase 60 Hz electrical service and should be protected by
30 -amp time -delay fuses or circuit breakers KW Rating per voltage
(240/2081. This appliance is manufactured with neutral connected to the
frame. Power cord should be purchased separately.
Note:
These appliances are not approved for 120 -volt operation.
Gas Requirements:
GTUN275GM Gas Dryer - This appliance should be connected to an
individual branch circuit with 120 -volt single -phase 60 Hz electrical service
and should be protected by 20 -amp time -day fuses or circuit breakers.
This appliance is equipped with a 4 -foot long flexible U.S. listed 20 -amp
power cord to match a 20 -amp receptacle.
Note:
Gas Rated input 20,000 BTU /HR. Factory equipped for natural gas. Tested
for LP gas. LP gas supply requires a conversion kit. Have a qualified gas
technician install a conversion kit before use.
Dryers must be exhausted to the outside.
Installation Information:
For complete information, see installation instructions packed with
the product.
For answers to your Monogram ®GE Profile- or
GE® appliance questions, visit our website at
geappliances.com or call GE Answer Center®
service, 800.626.2000.
imagination at work
RECEIVED
CITY OF TUKWILA
FEB 0 6 2013
PERMIT CENTER
75.5"
52.9'
27.7'
0
••I 00
18.6'
12.
20.2' —
Gas Inlet
(Rear view of appliance/
Woter inlets
irearl
14-29"
:- Drain outlet
(rear/
14— .3.9"
26.8"
*26.7'
36.5"
30.85"
Specification Revised 6/12
\\\
Listed by
Underwriters
Laboratories
360330
.♦
07.
co-
r
c T-U4 20745E VGM
&I `I r Unitized Spacemaker® 3.4 DOE Cu. Ft. Stainless Steel Washer and 5.9 Cu. Ft. Dryer
Dimensions and Installation information lin inches)
R1"E °JSIGT�ki _ .
For answers to your Monogram ®GE Profile' or
GE® applionce questions, visit our website at
geapplionces.com or call GE Answer Center®
service, 800.626.2000.
imagination at work
For complete information, see installation instructions packed with your dryer.
Ducting Materials:
For best performance, this dryer should be vented with 4" diameter all rigid metal exhaust duct. If rigid metal
duct cannot be used, then UL- listed flexible metal (semi- rigid) ducting can be used (Kit WX08X10077). In special
installations, it may be necessary to connect the dryer to the house vent using a flexible metal (foil -type) duct.
A UL- listed flexible metal (foil -type) duct may be used ONLY in installations where rigid metal or flexible metal
(semi- rigid) ducting cannot be used AND where a 4" diameter can be maintained throughout the entire length
of the transition duct. Please see installation instruction packed with your dryer for complete instructions when
using flexible metal (foil type) ducting.
Exhaust Length Calculation:
1. Determine the number of 90° turns needed for your installation. If you exhaust to the side or bottom of dryer,
add one turn.
2. The maximum length of 4" rigid (aluminum or galvanized) duct which can be tolerated is shown in the table.
A turn of 45° or less may be ignored. Two 45° turns within the duct length should be treated as a 90° elbow A turn
over 45° should be treated as a 90° elbow.
Dryers must be exhausted to the outside.
Caution: For personal safety do not terminate exhaust into a chimney, under any enclosed house floor (crawl
space), or into an attic, since the accumulated lint could create a fire hazard or moisture could cause damage.
Never terminote the exhaust into a common duct or plenum with a kitchen exhaust, since the combination of lint
and grease could create a fire hazard.
Exhaust ducts should be terminated in a dampered wall cap to prevent back drafts, bird nesting, etc. The wall cap
must also be located at least 12" above the ground or any other obstruction with the opening pointed down.
Special Installation Requirements
Alcove or Closet Installation:
• If your dryer is approved for installation in an alcove or closet, it will be stated on a label on the dryer back
• The dryer MUST be exhausted to the outside.
• Minimum clearances between dryer cabinet and adjacent walls or other surfaces are
0" either side and rear
1" front and top
• Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 76 -1 /2:'
• Closet doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq. in. of open area
equally distributed. If this closet contains both a washer and a dryer, doors must contain a minimum of 120 sq. in.
of open area equally distributed.
• No other fuel- burning appliance shall be installed in the same closet with a gas dryer
Bathroom or Bedroom Installation:
• The dryer MUST be exhausted to the outdoors.
• The installation must conform with the local codes, or in the absence of local codes, with the National Electric
Code and National Fuel Gas Code, ANSI Z223 for gas dryers.
Minimum Clearances other than Alcove or Closet Installation:
• Minimum clearances to combustible surfaces
0" either side and rear
1" front and top
Listed by
Underwriters
Laboratories
Specification Revised 6/12 360330
RECOMMENDED MAXIMUM LENGTH
Exhaust Hood Types
Recommended
Use only for short
run installations
4" DIA
4- DIA
�
��
4" DIA
21
'14'7'
of90)°"
Elbow's
Rigid
Metal
Rigid
Metal
0
56 Feet
-. _
ee
42 Feet
3_ --
ee
For answers to your Monogram ®GE Profile' or
GE® applionce questions, visit our website at
geapplionces.com or call GE Answer Center®
service, 800.626.2000.
imagination at work
For complete information, see installation instructions packed with your dryer.
Ducting Materials:
For best performance, this dryer should be vented with 4" diameter all rigid metal exhaust duct. If rigid metal
duct cannot be used, then UL- listed flexible metal (semi- rigid) ducting can be used (Kit WX08X10077). In special
installations, it may be necessary to connect the dryer to the house vent using a flexible metal (foil -type) duct.
A UL- listed flexible metal (foil -type) duct may be used ONLY in installations where rigid metal or flexible metal
(semi- rigid) ducting cannot be used AND where a 4" diameter can be maintained throughout the entire length
of the transition duct. Please see installation instruction packed with your dryer for complete instructions when
using flexible metal (foil type) ducting.
Exhaust Length Calculation:
1. Determine the number of 90° turns needed for your installation. If you exhaust to the side or bottom of dryer,
add one turn.
2. The maximum length of 4" rigid (aluminum or galvanized) duct which can be tolerated is shown in the table.
A turn of 45° or less may be ignored. Two 45° turns within the duct length should be treated as a 90° elbow A turn
over 45° should be treated as a 90° elbow.
Dryers must be exhausted to the outside.
Caution: For personal safety do not terminate exhaust into a chimney, under any enclosed house floor (crawl
space), or into an attic, since the accumulated lint could create a fire hazard or moisture could cause damage.
Never terminote the exhaust into a common duct or plenum with a kitchen exhaust, since the combination of lint
and grease could create a fire hazard.
Exhaust ducts should be terminated in a dampered wall cap to prevent back drafts, bird nesting, etc. The wall cap
must also be located at least 12" above the ground or any other obstruction with the opening pointed down.
Special Installation Requirements
Alcove or Closet Installation:
• If your dryer is approved for installation in an alcove or closet, it will be stated on a label on the dryer back
• The dryer MUST be exhausted to the outside.
• Minimum clearances between dryer cabinet and adjacent walls or other surfaces are
0" either side and rear
1" front and top
• Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 76 -1 /2:'
• Closet doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq. in. of open area
equally distributed. If this closet contains both a washer and a dryer, doors must contain a minimum of 120 sq. in.
of open area equally distributed.
• No other fuel- burning appliance shall be installed in the same closet with a gas dryer
Bathroom or Bedroom Installation:
• The dryer MUST be exhausted to the outdoors.
• The installation must conform with the local codes, or in the absence of local codes, with the National Electric
Code and National Fuel Gas Code, ANSI Z223 for gas dryers.
Minimum Clearances other than Alcove or Closet Installation:
• Minimum clearances to combustible surfaces
0" either side and rear
1" front and top
Listed by
Underwriters
Laboratories
Specification Revised 6/12 360330
a
GTUN275EM /GM
GE® 27" Unitized Spacemaker® 3.4 DOE Cu. Ft. Stainless Steel Washer and 5.9 Cu. Ft. Dryer
Features and Benefits
• 3 wash /spin speed combinations - Speeds are matched to fabric type
for great clothes care
• 9 wash cycles - Cycles are designed to specifically handle various
fabrics and soils
• Auto -load sensing with 5 water levels - Washer will automatically
measure the load size and add just the right amount of water
• Bleach and fabric softener dispensers - Solutions are automatically
mixed with wash water for clean, bright, soft -to- the -touch results
• Rotary - electronic controls (washer) - Simplify cycle selection
• Cycle status lights - Provide accurate cycle times
• Rotary - electromechanical controls (dryer) - Allow fast, easy cycle
selection
• Stainless steel washer basket - Long - lasting stainless steel finish
resists rust and won't chip, peel or snag clothes
• Model GTUN275EMWW - White on white (Electric)
• Model GTUN275GMWW - White on white (Gas)
Ulf imagination at work
Modified Energy Factor (MEF)
2.02
Water Factor (WF)
5.65
ENERGY STAR
As an ENERGY STAR®
partner, GE has determined
that this product meets the
ENERGY STAR guidelines
for energy efficiency.
Specification Revised 6/12 360330
\\....
/
1 II
J
ENERGY STAR
As an ENERGY STAR®
partner, GE has determined
that this product meets the
ENERGY STAR guidelines
for energy efficiency.
Specification Revised 6/12 360330
SEPARATE PERMIT
REQUIRED FOR:
Mechanical
Electrical
Plumbing
Gas Piping
City of Tukwila
BUILDING DIVISION
PROJECT INFORMATION
Parcel Number
004000 -0900
Name
EDGEWOOD APARTMENTS LLC
Site Address
3730 S 148TH ST 98168
Legal
ADAMS HOME TRS POR OF S 30 FT OF LOTS 10 & 11 &
W 1/2 OF LOT 23 & ALL OF LOT 24 & POR OF LOTS 25 &
26 LESS POR SD LOTS 10 & 25 & 26 LY WLY & NLY OF
FOLG DESC LINES - BAAP ON N LN OF S 30 FT OF SD
LOT 10 LY 120 FT ELY OF PACIFIC HWY S TH S PLW SD
HWY 200 FT TH W PLW N LN SD LOTS 25 & 26 TO ELY
MGN OF SD HWY & TERMINUS OF LN DESC LESS E 88
FT OF SD LOT 11 LESSS 10 FT OF SDLOT24 &OFW
1/2 OF LOT 23 LESS RD
CONTACT/OWNER
MOHAMMAD AMINPOUR
425 - 502 -9146
3730 S 148TH ST
TUKWILLA, WA 98168
TABLE OF CONTENTS
A1.1 SITE PLAN
A2.1
A2,2
A3.1
A3.2
TYPICAL UNIT PLAN
PARTIAL FLOOR PLAN
DETAILS
RISER DIAGRAM
A4.0 DRYER SPEC.
VICINITY MAP
Washer/Dryer Addition
Edgewood Apartments
9 -27 -2011 3730 S 148th St. Tukwilla WA 98168
REVISIONS
No changes shall be made to the scope
of work without prior approval of
Tukwila Building Division.
NOTE: Revisions will require a new plan submittal
and may include add'ctional plan review fees.
REVIEWED FOR
CODE COMPLIANCE
APPROVED
OCT 0 7 2011
BUILDING
of
ila
ISION
FILE COPY
',stink No. AAl■-■1-
Plan review approval is subject to errors and omission
Approval of construction documents does not authorize
the violation of any adopted code or ordinance. Receipt
of approved Reid Copy and conditions is acmowledged:
1'1H91
1
City Of lbkwila
BUILDING DMSION
A0.0
ECEOVED
SEP 29 2011
PERMIT CENTER
/
S 146th St 99
IX
S 148th
I
SITE
St X
1
I
VICINITY MAP
Washer/Dryer Addition
Edgewood Apartments
9 -27 -2011 3730 S 148th St. Tukwilla WA 98168
REVISIONS
No changes shall be made to the scope
of work without prior approval of
Tukwila Building Division.
NOTE: Revisions will require a new plan submittal
and may include add'ctional plan review fees.
REVIEWED FOR
CODE COMPLIANCE
APPROVED
OCT 0 7 2011
BUILDING
of
ila
ISION
FILE COPY
',stink No. AAl■-■1-
Plan review approval is subject to errors and omission
Approval of construction documents does not authorize
the violation of any adopted code or ordinance. Receipt
of approved Reid Copy and conditions is acmowledged:
1'1H91
1
City Of lbkwila
BUILDING DMSION
A0.0
ECEOVED
SEP 29 2011
PERMIT CENTER
EXIST
PARKING
Afe uJO
1a)aa75-41
S_14 TN ST
SITE PLAN
I'= 50' -0'
N
Washer / Dryer Addition
Edgewood Apartments
9 -27 -11 3730 S 148th St. Tukwilla WA 98168
REVIEWED FOR
CODE COMPLIANCE
APPROVED
OCT 0 7 2011
City of Tukwila
BUILDING DIVISION
ECE9VED
SEP 2 9 2011
CENTER
A1.1
1 / 2" HW
1 / 2" C
Deck
Living Nook
EXISTING CONSTRUCTION
Hall
Br 1
— Kit
50 CFM MIN WALL MOUNT FAN
VENT TO EXTERIOR
L
Br 2
4"" DRYER DUCT
3' VENT DUCT IN
NEW SOFFIT
DISCHARGE 36"
FROM ANY
OPERABLE
OPENING
DUCT LENGTH
NOT TO EXCEED 33' (3 EL
ALLOWABLE PER
W/D MFG
310"MIN rrp
Typical Apartment Unit
Scale: 1 / 4" = 1'-0"
Washer / Dryer Addition
Edgewood Apartments
9-27- 2011 3730 S 148th St. Tukwilla WA 98168
REVIEWED FOR
CODE COMPLIANCE
APPROVED
OCT 07 2011
City of Tukwila
BUILDING DIVISION
WS MAX)
A2.1
NOTE: All plumbing penetrations shall be fire stopped per code such that the required fire resistance shall not be reduced.
MEWED
SEP 29 2011
CRIB
C .1;
i
TO SIDE SEWER
N
Typical Partial Plumbing Plan c!Ds
Scale: 1" = 10 ft
Washer /Dryer Addition
Edgewood Apartments
9 -27 -11 3730 S 1 48th St. Tukwilla WA 98168
LEGEND
NEW
EXISTING - - - - -
REVIEWED FOR
CODE COMPLIANCE
APPROVED
OCT 0 7 2011
City BUILD NG of DIVISION
ISION
A2.2
ECEOVED
SEP 29 2011
TEF
FLOOR
:llll:/f!'1lE //I f!1 /!I /l!1 /l;Elf!•l.•1'l.•1f1!'lf /•!.•!1 • •
.:' L/ Ar.• fl Ll:/l 19lll1l• 41r111,111rI:ll /1IG /AIrfAV /l• /'A I1rI:11+l1'
SECTION
CEILING
•' -9" MIN
5/8" TYPE 'X' GWB
REVIEWED FOR
CODE COMPLIANCE
APPROVED
OCT 0 7 2011
City of Tukwila
BUILDING DIVISION
FIELD VERIFY ADEQUATE AREA FOR ALL DUCTS AND CROSSES
TO BE INSTALLED
Note: continuous 5/8" type x gwb above
dropped ceiling /chase and @ unit separation wall
1 Hr Chase
Scale: 1" = 1' -0"
Edgewood Apartments
9- 27-11 3730 S 148th St. Tukwilla WA 98168
A3.
•
SEP 2 9 2011
T CENTEP
ROOF
2 "V -►'
1 1/2" V-
THIRD FLOOR
'-1 1 / 2" V
1 1/2"V--
SECOND FLOOR
1 1 /2" V
FIRST FLOOR
2" W
NEW 3" W
CRAWL SPACE
-4-2" W
2" W
EXISTING 4"
Riser Diagram
Washer/Dryer Addition
Edgewood Apartments
9-27-11 3730 S 148th St. Tukwilla WA 98168
CO
REVIEWED FOR
CODE COMPLIANCE
APPROVED
OCT 0 7 2011
City of BUILDING DIVISION
SION
A3.2
ECE ED
SEP 29 2011
CENTER
iripool
PRODUCT MODEL NUMBERS
Electrical This dryer requires a 3 or 4 wire, single
phase, 120/240 volt, 60 Hz. AC only electrical supply
(or 3 or 4 wire, 120/208 volt electrical supply, if
specified on the serial /rating plate) on a separate
30 -amp circuit, fused on both sides of the line.
Connect to an individual branch circuit. Do not have
a fuse in the neutral or grounding circuit.
Exhaust venting Exhaust your dryer to the outside.
4" (1 02 mm) diameter vent Is required. Rigid or flexible
metal exhaust vent must be used. Do not use plastic
or metal foil vet. Exhaust hood must be at least
12" (305 min) from the ground or any object that
may be in the path of the exhaust.
Hood styles A & E3 are recommended.
Q 4"
(102 mm)
,4 "►
't4„«
(102 mm)
(102 mm)
.\ 21/2"
(64 mm)
A. Louvered hood
B. Box hood
C. Angled hood (acceptab /e)
The Vent system chart provides venting requirements
that will help achieve best drying performance.
NOTE: Side and bottom exhaust installation have a 90"
turn inside the dryer. To deterrnine maximum exhaust
length, add one 90' turn to the chart.
Do not use vent runs longer than specified in vent
length chart.
Deterrnine the number of elbows you will need.
Select the route that will provide the straightest and
most direct path outdoors.
Plan the installation to use the fewest number of
elbows and turns.
Use the fewest 90' turns possible.
Electric Dryer
OVERALL DIMENSIONS
Dryer dimensions
(006 mall
.25 non)
1356 man
F30 nun)
nyM r•u.
01014.1
1
11m
Minimum Required Spacing
r
7" --r
(178 min)
4"
(102 mm)\
0 116"
(460 mm)
1"
(25 mm)
---t-
n••, I
(n. min)
1"
(25 mm)
For closet installation, with a door,
the minimum ventilation openings
in the top and bottom of the door
are required. Louvered doors with
equivalent air ventilation openings
are acceptable.
Most installations require a
minimum 5" (127 mm) clearance
behind the dryer for the exhaust
vent with elbow. See "Venting
Requirements."
•
v7 r.• 11276 mm)
47 m )
30" min.
(990 mm)
1" r
(25 mm)
6"
(152 mm)
(25 m
REVIEWED FOR
CODE COMPLIANCE
APPROVED
OCT 0 7 2011
BUILDING Tukwila
DIVISION
I - -'
3"
(76 mm)
4"
(102 mm) 1
34" recommended
(664 mm)
18" min.
(457 mm)
(76 mm) t
48 in.'
(310 cmT)
24 tn.'
(155 cm')
_:✓ - . (76 rnm) 6ye6
t�
25 mm
to (25 1
(25 mm)
ACM R
SEP 29 2011
NTEF
Boca ,10 Whirlpool Corporation pohr.y includes , contin,rous colnnntment to improvo
(pr' pr0Cll1,;16 '+vG ieselvt; 111r• I lyllt 10 Charlyb II Ii11erldiJ o110 8f %c Cllr:, tl(ln;, v..!f i 11 ,1 ,11
Dimensions aro for planning purposes only. For complete details. sbe Instatlittion
packed Ar.11l p'oUu .t. Spdt,n•Cat oi, 5u UlOGt lJ CrldnCJU wItiIou( notice.
2
A o
vent system cnart
Number of
90" elbows
Type
of vent
Box /louvered
hoods
Angled rr
hoods
0
Rigid metal
64 ft (20 m)
58 ft. (17.7 m)
i1
1
Rigid metal
54 ft. (16.5 rn)
>—
48 ft. (14.6 m)
2
Rigid metal
44 ft. (13.4 m)
r
38 tt. (11.6 rn)
3
Rigid metal
35 ft. (10.7 m)
29 ft. (8.8 m)
-r
4
X.1 +.,r,",C h. ..:L;9X8•"?�'-�"'^t
Rigid metal
� A.+y.
27 tt. (8.2 m)
21 ft. (6.4 m) it
..t�«Y. .:�{y'
;1;.+,��. T.. tV4 ",w 1.,FSt• "�t
Do not use vent runs longer than specified in vent
length chart.
Deterrnine the number of elbows you will need.
Select the route that will provide the straightest and
most direct path outdoors.
Plan the installation to use the fewest number of
elbows and turns.
Use the fewest 90' turns possible.
Electric Dryer
OVERALL DIMENSIONS
Dryer dimensions
(006 mall
.25 non)
1356 man
F30 nun)
nyM r•u.
01014.1
1
11m
Minimum Required Spacing
r
7" --r
(178 min)
4"
(102 mm)\
0 116"
(460 mm)
1"
(25 mm)
---t-
n••, I
(n. min)
1"
(25 mm)
For closet installation, with a door,
the minimum ventilation openings
in the top and bottom of the door
are required. Louvered doors with
equivalent air ventilation openings
are acceptable.
Most installations require a
minimum 5" (127 mm) clearance
behind the dryer for the exhaust
vent with elbow. See "Venting
Requirements."
•
v7 r.• 11276 mm)
47 m )
30" min.
(990 mm)
1" r
(25 mm)
6"
(152 mm)
(25 m
REVIEWED FOR
CODE COMPLIANCE
APPROVED
OCT 0 7 2011
BUILDING Tukwila
DIVISION
I - -'
3"
(76 mm)
4"
(102 mm) 1
34" recommended
(664 mm)
18" min.
(457 mm)
(76 mm) t
48 in.'
(310 cmT)
24 tn.'
(155 cm')
_:✓ - . (76 rnm) 6ye6
t�
25 mm
to (25 1
(25 mm)
ACM R
SEP 29 2011
NTEF
Boca ,10 Whirlpool Corporation pohr.y includes , contin,rous colnnntment to improvo
(pr' pr0Cll1,;16 '+vG ieselvt; 111r• I lyllt 10 Charlyb II Ii11erldiJ o110 8f %c Cllr:, tl(ln;, v..!f i 11 ,1 ,11
Dimensions aro for planning purposes only. For complete details. sbe Instatlittion
packed Ar.11l p'oUu .t. Spdt,n•Cat oi, 5u UlOGt lJ CrldnCJU wItiIou( notice.
2
A o
02 -01 -2013
ZZ Jim Hagg0P1.11UIayor
blefithrinient tea-amain
MOHAMMAD AMINPOUR
3730 S 148 ST - OFFICE
TUKWILA WA 98168
RE: Permit No. M11 -141
EDGEWOOD APTS - UNITS 12, 28 & 54
3730 S 148 ST TUKW
Dear Permit Holder:
)'euelopiient
tacIf: ace; Director
In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building
Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National
Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and
become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date
of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has
begun for a period of 180 days. Your permit will expire on 03/21/2013.
Based on the above, you are hereby advised to:
1) Call the City of Tukwila Inspection Request Line at 206 -431 -2451 to schedule for the next or final inspection.
Each inspection creates a new 180 day period, provided the inspection shows progress.
-or-
2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to
expire. Address your extension request to the Building Official and state your reason(s) for the need to extend
your permit.
The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your
extension request is granted, you will be notified by mail.
In the event you do not call for an inspection and/or receive an extension prior to 03/21/2013, your permit will become null
and void and any further work on the project will require a new permit and associated fees.
Thank you for your cooperation in this matter.
Sincerely,
Bill Rambo
Permit Technician
File: Permit File No. M11 -141
640,0 Scut center7364evard, Suit e. #100 Tul ry la, Wasli'rrigtoh 98188 • Phone 206:431 -.3670 • Fax 206 -431 -3663
i
City of Tukwila
Jim Haggerton, Mayor
Department of Community Development Jack Pace, Director
August 22, 2012
Mohammad Aminpour
Manager, Edgewood Apartments
3730 S 148 Street
Tukwila, WA 98168
RE: Request for Extensions
Edgewood Apartments
Dear Mr. Aminpour,
This letter is in response to your written request for an extension to multiple permits. The
Building Official, Bob Benedicto, has reviewed your letter and considered your request to extend
the permits. The City of Tukwila Building Division will be extending your permits an additional
180 days from the date of expiration as shown below:
New expiration date of February 18, 2013
M11 -081, M11 -136, M11 -137, M11 -138
PG11 -083, PG11 -143, PG11 -144, PG11 -145
New expiration date of March 21, 2013
M11-135, M11 -139, M11 -140, MI 1 -141, M11 -142, M12 -001 through M12 -007
PG 11 -142, PG 12 -002 through PG 12 -008
If you should have any questions, please contact our office at (206) 431 -3670.
Sincerely,
W:\Pemdt Center\Extension Letters \Permits\2011\M11 -081 Permit Extension.doc
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665
EDGEWOOD APARTMENTS
3730 South 148th Street
Tukwila, WA 98168
(206) 246 -3269
August 15, 2012
Mr. William Rambo
City of Tukwila
Department of Community Development
6300 Southcenter Blvd., Suite #100
Tukwila, WA 98188
Dear Mr. Rambo,
The primary work for the following permits has been completed but we still need to do some
final requirements in order to get final inspection approval. Therefore, I am requesting for
extension of time to complete the fmal work requirements for these permits.
Mechanical permit numbers are as follows:
M11 -081, M11 -136, M11 -137, M11 -138: expiration date 8 -21 -12
M11 -135, M11 -139, M11 -140, M11 -141, M11 -142, M12 -001, M12 -002, M12 -003, M12 -004,
M12 -005, M12 -006, M12 -007: expiration date 9 -22 -12
Pluming permit numbers are as follows:
PG11 -083, PG11 -143, PG11 -144, PG11 -145: expiration date 8 -21 -12
PG11 -142, PG12 -002, PG12 -003, PG12 -004, PG12 -006, PG12 -007, PG12 -008: expiration
date 9 -22 -12 1'G I? -005
I would like to thank you in advance for your kind consideration of this matter. Please feel
free to contact me at (206) 353 -7857 if you need further information or explanation.
Sincerely,
ammad Aminpour, Manager, Edgewood Apartments, LLC RECEIVED
CM OF TUKWILA
AUG 15.20121
o, 411d J4
1-141/46e4 /604/06dd,
6/z/A02
PERMIT CENTER
tlIik) .-
q, -'. 09212,1i 3
.tip
EDGEWOOD APARTMENTS
3730 South 148th Street
Tukwila, WA 98168
(206) 246 -3269
August 15, 2012
Mr. William Rambo
City of Tukwila
Department of Community Development
6300 Southcenter Blvd., Suite #100
Tukwila, WA 98188
Dear Mr. Rambo,
The primary work for the following permits has been completed but we still need to do some
final requirements in order to get final inspection approval. Therefore, I am requesting for
extension of time to complete the final work requirements for these permits.
Mechanical permit numbers are as follows:
M11 -081, M11 -136, M11 -137, M11 -138: expiration date 8 -21 -12
M11 -135, M11 -139, M11 -140, M11 -141, M11 -142, M12 -001, M12 -002, M12 -003, M12 -004,
M12 -005, M12 -006, M12 -007: expiration date 9 -22 -12
Pluming permit numbers are as follows:
PG11 -083, PG11 -143, PG11 -144, PG11 -145: expiration date 8 -21 -12
PG11 -142, PG12 -002, PG12 -003, PG12 -004, PG12 -006, PG12 -007, PG12 -008: expiration
date 9 -22 -12 TG 0- 005
I would like to thank you in advance for your kind consideration of this matter. Please feel
free to contact me at (206) 353 -7857 if you need further information or explanation.
Sincerely,
r/x ley
ohammad Aminpour, Manager, Edgewood Apartments, LLC RECEIVED
CITV OF TUKWR,A
AUG 1 5.20121
HERMIT CENTER
08 -01 -2012
City of Tukwila Jim Haggerton, Mayor
Department of Community Development Jack Pace, Director
MOHAMMAD AMINPOUR
3730 S 148 ST - OFFICE
TUKWILA WA 98168
RE: Permit No. M11 -141
EDGEWOOD APTS - UNITS 12, 28 & 54
3730 S 148 ST TUKW
Dear Permit Holder:
In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building
Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National
Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and
become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date
of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has
begun for a period of 180 days. Your permit will expire on 09/22/2012.
Based on the above, you are hereby advised to:
1) Call the City of Tukwila Inspection Request Line at 206 -431 -2451 to schedule for the next or fmal inspection.
Each inspection creates a new 180 day period, provided the inspection shows progress.
-or-
2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to
expire. Address your extension request to the Building Official and state your reason(s) for the need to extend
your permit.
The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your
extension request is granted, you will be notified by mail.
In the event you do not call for an inspection and/or receive an extension prior to 09/22/2012, your permit will become null
and void and any further work on the project will require a new permit and associated fees.
Thank you for your cooperation in this matter.
,AAA4sed
File: Permit File No. M11 -141
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206 -431 -3670 • Fax 206 - 431 -3665
City of f Tulctivila
Jim Haggerton, Mayor
Department of Community Development Jack Pace, Director
MOHAMMAD AMINPOUR
3730 S 148 ST - OFFICE
TUKWILA WA 98168
RE: Permit No. M11 -141
EDGEWOOD APTS - UNITS 12, 28 & 54
3730 S 148 ST TUKW
Dear Permit Holder:
In reviewing our current records, the above noted permit has not received a final inspection by the City of
Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform
Plumbing Code and /or the National Electric Code, every permit issued by the Building Division under the
provisions of these codes shall expire by limitation and become null and void if the building or work authorized
by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work
authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180
days. Your permit will expire on 04/09/2012.
Based on the above, you are hereby advised to:
1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final
inspection. Each inspection creates a new 180 day period, provided the inspection shows progress.
-or-
2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is
due to expire. Address your extension request to the Building Official and state your reason(s) for
the need to extend your permit.
The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is
determined that your extension request is granted, you will be notified by mail.
In the event you do not call for an inspection and/or receive an extension prior to 04/09/2012, your permit will
become null and void and any further work on the project will require a new permit and associated fees.
Thank you for your cooperation in this matter.
Sincerely,
-1,-4 -,,,L_
Bill Rambo
Permit Technician
File: Permit File No. MI 1 -141
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665
•
•
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: M11 -141 DATE: 09 -29 -11
PROJECT NAME: EDGEWOOD APTS - UNITS 12, 28 & 54
SITE ADDRESS: 3730 S 148 ST
X Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter #
Revision # After Permit Issued
DEPARTMENTS:
Bing Divi Is o
iJll� l n
Public Works ❑
Fire Prevention
Structural
n
Planning Division
❑ Permit Coordinator
DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 10-04-11
Complete
Comments:
tzi
Incomplete
Not Applicable
Permit Center. Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES /THURS ROUTING:
Please Route RI Structural Review Required n No further Review Required 111
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS:
Approved
Notation:
Approved with Conditions
DUE DATE: 1 1 -01 -1 1
Not Approved (attach comments) ❑
REVIEWER'S INITIALS: DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents /routing slip.doc
2 -28 -02
•
CITY OF TUKWILA
Department of Community Development
6300 Southcenter Boulevard, Tukwila, WA 98188
Telephone: (206) 431-367o FAX (206) 431 -3665
E -mail: tukplanoci.tukwila.wa.us
Permit Center /Building Division
206 431 -367o
Public Works Department
206 433 -0179
Planning Division
206 431 -367o
AFFIDAVIT IN LIEU OF CONTRACTOR REGISTRATION
STATE OF WASHINGTON)
) ss.
COUNTY OF KING )
e0
[p print name]
, states as follows:
PERMIT NO: DUI -n0 6lm
MII- IH2- -�
?-U- Wz -W1
1. 1 have made application for a permit from the City of Tukwila, Washington.
2. I understand that state law requires that all building construction contractors be registered with the
State of Washington. The exceptions to this requirement are stated under Section 18.27.090 of the
Revised Code of Washington, a.copy of which is printed on the reverse side of this Affidavit. I have
read or am familiar with RCW 18.27.090.
3. I understand that prior to issuance of a permit for work which is to be done by any contractor, the
City of Tukwila must verify either that the contractor is registered by the State of Washington, or that
one of the exemptions stated under RCW 18.27.090 applies.
4. In order to provide verification to the City of Tukwila of my compliance with this requirement, I
hereby attest that after reading the exemptions from the registration
I consider the work authorized under this permit to be exept under number requirement a, a d will therefore
not be performed by a registered contractor.
5. I understand that the licensing provision of RCW 19.28.161 through 19.28.271 shall not apply to
persons making electrical installations on their own property or to regularly employed employees
working on the premises of their employer. The proposed electrical work is not for the construction
of a new building for rent, sale or lease.
I understand that I may be waiving certain rights that I might otherwise have under state law in any decision
to engage an unregistered contractor to perform construction work.
Signed and sworn to before me this
day of Serie/114' er
ARY PUBLIC in and,for the State of Washington
Residing at /fl l /7v County
Name as commissioned: iaZra/
My commission expires: 051--d-9 —/ V
8.27.090 Exemptions. The re tion provisions of this chapter do not apply to
1. An authorized representative of the United States
government, the state of Washington, or any incorporated
city, town, county, township, irrigation district, reclamation
district, or other municipal or political corporation or
subdivision of this state;
2. Officers of a court when they are acting within the scope
of their office;
3. Public utilities operating under the regulations of the
utilities and transportation commission in construction,
maintenance, or development work incidental to their own
business;
4. Any construction, repair, or operation incidental to the
discovering or producing of petroleum or gas, or the
drilling, testing, abandoning, or other operation of any
petroleum or gas well or any surface or underground mine
or mineral deposit when performed by an owner or lessee;
5. The sale of any finished products, materials, or articles of
merchandise that are not fabricated into and do not become
a part of a structure under the common law of fixtures;
6. Any construction, alteration, improvement, or repair of
personal property performed by the registered or legal
owner, or by a mobile /manufactured home retail dealer or
manufacturer licensed under chapter 46.70 RCW who shall
warranty service and repairs under chapter 46.70 RCW;
7. Any construction, alteration, improvement, or repair
carried on within the limits and boundaries of any site or
reservation under the legal jurisdiction of the federal
government;
8. Any person who only furnished materials, supplies, or
equipment without fabricating them into, or consuming
them in the performance of, the work of the contractor,
9. Any work or operation on one undertaking or project by
one or more contracts, the aggregate contract price of
which for labor and materials and all other items is less
than five hundred dollars, such work or operations being
considered as of a casual, minor, or inconsequential nature.
The exemption prescribed in this subsection does not apply
in any instance wherein the work or construction is only a
part of a larger or major operation, whether undertaken by
the same or a different contractor, or in which a division of
the operation is made into contracts of amounts less than
five hundred dollars for the purpose of evasion of this
chapter or otherwise. The exemption prescribed in this
subsection does not apply to a person who advertises or
puts out any sign or card or other device which might
indicate to the public that he or she is a contractor, or that
he or she is qualified to engage in the business of
contractor;
10. Any construction or operation incidental to the
construction and repair of irrigation and drainage ditches
of regularly constituted irrigation districts or reclamation
districts; or to farming, dairying, agriculture, viticulture,
horticulture, or stock or poultry raising; or to clearing or
other work upon land in rural districts for fire prevention
purposes; except when any of the above work is performed
by a registered contractor;
u. An owner` who contracts for a project with a registered
contractor, except that this exemption shall not deprive the
owner of the protections of this chapter against registered
and unregistered contractors. The exemption prescribed in
this subsection does not apply to a person who performs
the activities of a contractor for the purpose of leasing or
selling improved property he or she has owned for less than
twelve months;
12.E Any person working on his or her own property,
whether occupied by him or her or not, and any person
working on his or her personal residence, whether owned
by him or her or not but this exemption shall not apply to
any person who performs the activities of a contractor on
his or her own property for the purpose of selling,
demolishing, or leasing the property;
13. An owner" who performs maintenance, repair, and
alteration work in or upon his or her own properties, or
who uses his or her own employees to do such wotk;
14. A licensed architect or civil or professional engineer
acting solely in his or her professional capacity, an
electrician certified under the laws of the state of
Washington, or a plumber certified under the laws of the
state of Washington or licensed by a political subdivision of
the state of Washington while operating within the
boundaries of such political subdivision. The exemption
provided in this subsection is applicable only when the
person certified is operating within the scope of his or her
certification;
15. Any person who engages in the activities herein
regulated as an employee of a registered contractor with
wages as his or her sole compensation or as an employee
with wages as his or her sole compensation;
16. Contractors on highway projects who have been
prequalified as required by RCW 47.28.070, with the
department of transportation to perform highway
construction, reconstruction, or maintenance work;
17. A mobile /manufactured home dealer or manufacturer
who subcontracts the installation, set -up, or repair work to
actively registered contractors. This exemption only applies
to the installation, set -up, or repair of the
mobile /manufactured homes that were manufactured or
sold by the mobile /manufactured home dealer or
manufacturer;
18. An entity who holds a valid`eled cal.contractor's
license under chapter 19:28. RCW:tjf4teiaploys a certified
journeyman electrician;.* certiiiedtreside.ntial specialty
electrician, or an eleef rival trainee meeting the
requirements of chapter 19:28 RCW to perforrtt plumbing
work that is incidenthlly,:directly, and immediately
appropriate to the like -in -kind replacemezit'ofa household
appliance or other small household Utilittatioif equipment
that requires limited elerrtric: ewer end.limlted waste
and /or water connectione.4ii. 'rical trainee must be
supervised by a certified electrician while performing
plumbing work.
• Per Washington State Department of labor and industries. lessee has been
interpreted to be equivalent to owner for the purpose of these exemptions.