Loading...
HomeMy WebLinkAboutPermit M11-155 - US COAST GUARD RECRUITINGUS COAST GUARD RECRUITING 640 STRANDER BL M11-155 City ATukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206- 431 -2451 Web site: http: / /www.TukwilaWA.gov MECHANICAL PERMIT Parcel No.: 0005800037 Address: 640 STRANDER BL TUKW Project Name: U S COAST GUARD RECRUITING Permit Number: M11 -155 Issue Date: 12/01/2011 Permit Expires On: 05/29/2012 Owner: Name: BC PARTNERS LLC Address: C/0 MK PROPERTY SVC LLC , PO BOX 997 98065 Contact Person: Name: ALVIS ALDRICH Address: PO BOX 66070 , SEATTLE WA 98166 Email: AL @NWAIRESERVICES.COM Contractor: Name: NORTHWEST AIRE SERVICES INC. Address: PO BOX 66070 , SEATTLE WA 981696 Contractor License No: NORTHAS963K4 Phone: 253 - 223 -1890 Phone: 206 241 -2657 Expiration Date: 05/24/2012 DESCRIPTION OF WORK: REMOVAL OF ALL EXISTING INTERIOR DUCTWORK AND DIFFUSERS, (EXCLUDING SOURCE SPECIFIC EXHAUST AND FANS). INSTALL ALL NEW INTERIOR DUCTWORK .AND DIFFUSERS PER MECHANICAL DRAWINGS. INSTALL A NEW FACTORY BUILT, 0 -100% AIRSIDE ECONOMIZER TO THE EXISTING ROOFTOP UNIT. Value of Mechanical: $9,509.00 Type of Fire Protection: UNKNOWN Electrical Service Provided by: Permit Center Authorized Signature: I hereby certify that I have read and governing this work will be complie with Fees Collected: $306.06 International Mechanical Code Edition: 2009 Date: II-1°11 II ed this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. The granting of this permit does not pr . _ e to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this permit. Signature: ��% / Print Name: /' ' /t// This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Date: 47-1— 1% doc: IMC -4/10 M11 -155 Printed: 12 -01 -2011 • • PERMIT CONDITIONS Permit No. M11-155 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: 1MC -4/10 M11-155 Printed: 12 -01 -2011 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto://www.TukwilaWA.dov Mechanical Permit`No. Project No.`` MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *please print ** SITE LOCATION Site Address: (C4' L 3T(Z {t L? ^�L -6 Tenant Name: 5 ee,45 -/- lc4Ce KL- :tom -' tti-/ C- Property Owners Name lice 44_c. 1 Mailing Address: Po At* sivirt.,1;xu %, ;r_: City King Co Assessor's Tax No.: Pty j e 4i - tog 47 Suite Number: New Tenant: Floor: Yes ❑ .. No State Zip CONTACT PERSON — who do we contact when your permit is ready to be issued Name: 4�v"l A1da t Mailing Address: ?fir (r: fc= 1 c, E -Mail Address: N AT Cc,rr• Day Telephone: c`A3 1 City State Zip Fax Number: . a 41 31 MECHANICAL CONTRACTOR INFORMATION Company Name: Mailing Address: eazfin to0 eizA- Ai at- ` C.ra. V`?.Lc1t Contact Person: AL 41 R 1.:. -k, SaA44 -lam Loik City State Day Telephone: 2.b 4i Fax Number: 2 C) b 4 i E -Mail Address: A 1.114); rR E S^ Eic, J i aL 4 8 Contractor Registration Number: tIZT i-} A S 61(4;3 k 4 Zip ato 5.1 4431 Expiration Date: Z ARCHITECT OF RECORD - All plans must be stamped by architect of record Company Name: Mailing Address: Contact Person: E -Mail Address: City Day Telephone: Fax Number: State Zip ENGINEER OF RECORD — All plans must be stamped by engineer of record Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: State Zip H:\Applications\rorms- Applications On Line\2010 Applications \7 -2010 - Mechanical Permit Application.doc Revised: 7 -2010 bh Page 1 of 2 ��,o� Date Application Expires: _ \ (22___ Staff Initials: Wi 1 Valuation of project (contractor's bid price): $ Scope of work (please provide detailed information): 4Tifl D VA l_- Cc aft Gi pb 1 '+'i4.*aca4) & U d i t Satuae.e. DEL' i F 4 I ra t.:S- �i h: 1.� �+ _t- �,.re` �G l 1 C. lyzita. Ime �:� ,� rte bir+- 4s z fie. k.tcelqii,c cat tr ": 5. �I�Jje "1..1sAca i l hy� : kat_ 4 tai C3-1 DD% ace 9 _ -Icirencia w Replacement ❑ Commercial: New ❑ Replacement El or' i'-:- ti r. o,,3 Fuel Type: Electric ❑ Gas ❑ Other: Indicate type of mechanical work being installed and the quant'ty below: Unit Type: Qty Unit Type: Qty Unit Type: Qty ' Bioler /Compressor Qty furnace <100k btu air handling unit >10,000 cfm fire damper e$ 0 -3 hp /100,000 btu furnace >100k btu evaporator cooler di user :a- 3 -15 hp /500,000 btu floor furnace C-j ' ventilation fan connected to single duct >�1o8 /j t ermostat 15 -30 hp /1,000,000 btu (`'S suspended/wall /floor mounted heater ) ventilation system wood/gas stove 30 -50 hp /1,750,000 btu appliance vent hood and duct CP emergency` generator 50+ hp /1,750,000 btu (� T repair or addition to heat/refrig /cooling system ei Incinerator - domestic (2:/ other mechanical air handling unit <10,000 cfm 0 incinerator - comm/ind (! PERMIT APPLICATION NOTES -- Value of construction - in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review - applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 international building code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWN/�`EER�%R AAUU H D I AGENT: Signature: 1 -� ? L : i' Print Name: // /.5 k hF`�✓! l L- '� Mailing Address: / %! 44: L h6 It Date: J045 // Day Telephoners )Z2 64 C) City State 1p Date Application Accepted: 10 H:\ApplicationsWorms- Applications On Line\2010 Applications \7 -2010 - Mechanical Permit Application.doc Revised: 7 -2010 bh Pagc 2 of 2 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.TukwilaWA.gov RECEIPT Parcel No.: 0005800037 Permit Number: M11 -155 .Address: 640 STRANDER BL TUKW Status: PENDING Suite No: Applied Date: 10/25/2011 Applicant: U S COAST GUARD RECRUITING Issue Date: Receipt No.: RI1 -02335 Initials: WER User ID: 1655 Payment Amount: $306.06 Payment Date: 10/25/2011 01:55 PM Balance: $0.00 Payee: ALVIS ALDRICH TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd MC Authorization No. 515255 ACCOUNT ITEM LIST: Description 306.06 Account Code Current Pmts MECHANICAL - RES PLAN CHECK - RES 000.322.102.00.00 244.85 000.345.830 61.21 Total: $306.06 doc: Receiot -06 Printed: 10 -25 -2011 :INSPECTION RECORD Retain a copy with permit PERMIT NO. • CITY.•OFJUKWILA BUILDING DIVISION '6309.5oUthcgriter Eigd:, #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 . _ Pitije Ct. --.- .- ' 7. ----r". 2i-C. (2 r 44)/49 iN Type of Inspection: • r, Ai 09 /, Address: ---.-: ..7,--_-* 4 _Ye) .s57./t/.1.1,140Ade. Date Called: Spedial- initrUctiOni:t ? : -. • • • - . . . . • . . . Date Wanted:. Requester: Phone No: .VApproved_Per applicable codes. E3 Corrections required prior to approval. :' • • C9MMENTS: .. • - Date: 6"- INSPECTION NO. INSPECTION RECORD Retain a copy with permit yvAt1 -t S`j PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 1". (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: 21 E 0 -OIAS-7 G61.lRb Type of Inspection: iRc]1IC. N —IN Address: 6,90 ST ct /A 1■3'■ ,r 12 Date Called: Special Instructions: Date Wanted:. frm k 2 - 1 3 1 Ii m. Requester: Phone j'lo: � 3- 22_3 - 1 US 0 Approved per applicable codes. 11- Corrections required prior to approval. ?' COMMENTS: } Inspect: IDati2 _ 1 ��3 / n REIN�PECTION FEE R • QUIRED. Prior t,6 next inspection, fee must be paid t 6300 Southcenter Blvd:; Suite 1 0. Call to schedule reinspection. • T Y PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M11 -155 DATE: 10 -25 -11 PROJECT NAME: U S COAST GUARD RECRUITING SITE ADDRESS: 640 STRANDER BL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS `I Aim NM u li dir ivision Fire Prevention Public Works Structural u Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 10-27 -11 Complete Comments: Incomplete Not Applicable - .PermitCenter Use:Only.2 L .. �3r4?i�i•: INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required El REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Notation: Approved with Conditions DUE DATE: 11 -24 -11 Not Approved (attach comments) REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 Contractors or Tradespeople litter Friendly Page • General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name NORTHWEST AIRE SERVICES INC UBI No. 602387574 Phone 2062412657 Status Active Address Po Box 66070 License No. NORTHAS963K4 Suite /Apt. License Type Construction Contractor City Seattle Effective Date 5/24/2004 State WA Expiration Date 5/24/2012 Zip 98166 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Business Owner Information Name Role Effective Date Expiration Date BEDELL, GARY E President 05/24/2004 Amount BEDELL, KYLE E Vice President 05/19/2010 SHAW, BARBARA L Vice President 05/24/2004 05/19/2010 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 WESTERN SURETY CO 69710416 05/10/2004 Until Cancelled $12,000.00 05/24/2004 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 6 Hartford Caslns01SBAAM7713 05/11/2010 05/11/2012 $1,000,000.00 04 /08/2011 5 HARTFORD CAS INS CO 01 sba am7713 05/11/2009 05/11/2010 $2,000,000.0004 /28/2009 4 HARTFORD CAS INS CO 01SBAAM7713 05/11/2008 05/11/2009 $2,000,000.0004 /29/2008 3 HARTFORD CASUALTY INS CO 01SBAAM7713 05/11/2006 05/11/2009 $2,000,000.00 04 /07/2008 2 HARTFORD CAS INS CO 01SBAAM7713 05/11/2005 05/11/2006 $2,000,000.00 04 /18/2005 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https://fortress.wa.gov/lni/bbip/Print.aspx 12/01/2011 PROJECT GENERAL NOTES: 1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COMPLETE SECURITY OF THE BUILDING AND SITE WHILE THE JOB IS IN PROGRESS AND UNTIL THE WORK IS COMPLETED. THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO ENSURE THE SAFETY OF THE OCCUPANTS AND WORKERS AT ALL TIMES DURING THE COURSE OF THIS PROJECT. ALL OPERATIONS CONDUCTED ON THE PREMISES SHALL NOT BE OBJECTIONABLE BEYOND THE PROPERTY BOUNDARY LINES BY REASON OF NOISE, STEAM, ODOR, FUMES, GASSES, SMOKE, VIBRATION, HAZARDOUS CONDITIONS OR OTHER SUCH CAUSES. THE CONTRACTOR SHALL SECURE ALL SUCH INSPECTIONS AND FINAL APPROVALS FROM THE FIRE DEPARTMENT PRIOR TO OCCUPANCY. THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS, DIMENSIONS, DETAILS, ETC. AND NOTIFY THE ARCHITECT OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH THE WORK. COMMENCEMENT OF THE WORK CONSITUTES ACCEPTANCE OF EXISTING CONDITIONS AS ADEQUATE FOR THE PROPER COMPLETION OF THE WORK DETAILED HEREIN. EXISTING DETAILS, ELEVATIONS AND LOCATIONS TO BE JOINED SHALL BE VERIFIED BY THE CONTRACTOR PRIOR TO COMMENCEMENT OF WORK. IF CONDITIONS OR DETAILS DIFFER FROM THOSE SHOWN ON THE DRAWINGS, THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY SO THAT APPROPRIATE MODIFICATIONS CAN BE MADE BEFORE PROCEEDING. THERE SHALL BE NO DEVIATIONS FROM THE CONTRACT DOCUMENTS WITHOUT THE ARCHITECT'S WRITTEN APPROVAL THEREOF. THE CONTRACTOR AGREES TO DEFEND, INDEMNIFY AND HOLD URBAN SOLUTIONS STUDIO, LLC AND THE ARCHITECT HARMLESS FOR ANY CLAIMS ARISING AS A RESULT OF UNAPPROVED CHANGES. THE APPROVED PLANS SHALL BE KEPT IN A PLAN BOX AND SHALL NOT BE USED BY ANY WORKMAN. ALL CONSTRUCTION SETS SHALL REFLECT THE SAME INFORMATION. THE CONTRACTOR SHALL ALSO MAINTAIN IN GOOD CONDITION, ONE COMPLETE SET OF PLANS WITH ALL REVISIONS, ADDENDA AND CHANGE ORDERS ON THE PREMISES AT ALL TIMES, WHICH ARE TO BE UNDER THE OF THE JOB SUPERINTENDENT. SEE STRUCTRUAL NOTES REGARDING LUMBER GRADES, NAILING, MISCELLANEOUS STRUCTURAL STEEL, GROUTING AND ATTACHMENTS. DO NOT SCALE DRAWINGS - WRITTEN DIMENSIONS GOVERN. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY OF ANY AND ALL DISCREPANCIES. 11. ALL DIMENSIONS ARE TO THE CENTERLINE OF COLUMN, FACE OF STUD, CENTERLINE OF STUD OR FACE OF CMU - UNLESS OTHERWISE NOTED. 12. WHERE CONSTRUCTION DETAILS ARE NOT SHOWN OR NOTED FOR ANY PART OF THE WORK, THE DETAILS SHALL BE THE SAME FOR OTHER SIMILAR WORK. 13. ALL WORK SHALL BE COMPLETED IN ACCORDANCE WITH THE MANUFACTURER'S LATEST RECOMMENDATIONS OR WRITTEN DIRECTIONS. 14. FIRE EXTINGUISHERS: VERIFY REQUIREMENTS AND LOCATION WITH FIRE MARSHALL. FIRE EXTINGUISHER LOCATIONS SHALL NOT BE BLOCKED OR HIDDEN BY PRODUCT DISPLAYS, DECOR FIXTURES OR ANY SUCH SIMILAR MATERIALS. 15. EXIT DOORS SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. 16. EXIT DOORS, EXIT LIGHTS AND FIRE EXTINGUISHER LOCATIONS SHALL NOT BE CONCEALED OR OBSTRUCTED BY ANY DECORATIVE MATERIAL, DECOR OR FURNISHINGS. 17. FINISH FLOOR, TOP OF CONCRETE SLAB, DATUM = +0.00'. 18. ALL WOOD MEMBERS IN CONTACT WITH CONCRETE SHALL BE PRESSURE TREATED. 19. REFLECTED CEILING PLANS ARE FOR THE GENERAL INFORMATION OF THE CONTRACTOR. EXACT LOCATIONS OF LIGHTING FIXTURES AND CEILING MATERIALS SHOULD BE CONFIRMED PRIOR TO INSTALLATION. 20. PROVIDE SEISMIC BRACING AT ALL SUSPENDED ACOUSTICAL CEILING AREAS @ 12' O.C. IN BOTH DIRECTIONS. 21. THE CONTRACTOR SHALL VERIFY ALL WINDOW AND DOOR ROUGH OPENING REQUIREMENTS WITH DOOR AND WINDOW MANUFACTURERS PRIOR TO INSTALLATION. 22. EXTERIOR JOINTS AROUND WINDOWS AND DOOR FRAMES, OPENINGS BETWEEN WALLS AND FOUNDATION, BETWEEN WALLS AND ROOF AND OPENINGS AT PENETRATIONS OF UTILITY SERVICES THROUGH WALLS, FLOORS AND DOORS, AND ALL OTHER SUCH OPENINGS IN THE BUILDING ENVELOPE SHALL BE SEALED, CAULKED, GASKETED OR WEATHER - STRIPPED TO LIMIT AIR LEAKAGE AND PROHIBIT WATER PENETRATION. 23. ALL TEARS AND JOINTS IN BATT INSULATION TO BE SEALED WITH MANUFACTURER APPROVED METHODS. 24. PLUMBING, ELECTRICAL AND HVAC SYSTEMS ARE BIDDER - DESIGNED AND COVERED UNDER SEPARATE PERMIT. CONTRACTOR SHALL SUBMIT BIDDER- DESIGN DRAWINGS TO ARCHITECT FOR REVIEW PRIOR TO FABRICATION AND INSTALLATION. TENANT SPECIFIC NOTES (CONTINUED) 7. CATV DISTRIBUTION: CATV DISTRIBUTION PER DRAWING 8. RESTROOM EQUIPMENT: REFER TO DRAWINGS FOR ADA COMPLIANCE UNISEX RESTROOMS TO HAVE THE FOLLOWING FIXTURES — LIQUID SOAP DISPENSER, MIRROR ABOVE BASIN, SHELF ABOVE BASIN, TOILET PAPER DISPENSER, PAPER TOWEL DISPENSER, WASTE RECEPTACLE, 3 SHELF STORAGE 1 CABINET MOUNTED 2' -0" +/- ABOVE TOILET, COAT HOOK ON INSIDE SIDE OF DOOR, UNISEX RESTROOM SIGNAGE OF OUTSIDE OF DOOR INTERIOR WINDOWS: INTERIOR WINDOWS TO BE EQUIPPED WITH VERTICAL BLINDS WITH WHITE OR OFF -WHITE METAL OR VINYL SLATS, OPERABLE FROM OFFICE SIDE TENANT SPECIFIC NOTES: 1. COMPLY WITH LOCAL CODES AND STANDARDS OF CITY OF TUKWILA 2. PROVIDE ADA COMPLIANT RESTROOM 3. ELECTRICAL DISTRIBUTION: ADD DUPLEX RECEPTACLES AS REQUIRED FOR EACH WALL OF PRIVATE OFFICES AND CONFERENCE ROOM ADD MINIMUM OF TWO DUPLEX RECEPTACLES NO FURTHER THAN FOUR FEET APART, AS REQUIRED, AT COUNTERS AND ADMINISTRATIVE AREAS ADD DUPLEX RECEPTACLE AS REQUIRED IN STORAGE AREA TO POWER TENANT'S TELEPHONE EQUIPMENT ADD DUPLEX RECEPTACLES AS REQUIRED TO APPROXIMATE EIGHT FOOT INTERVALS BETWEEN RECEPTACLES AT OFFICES, COMMON AREAS AND FOYERS ADD TWO DUPLEX RECEPTACLES AT KITCHEN COUNTER ADD DUPLEX RECEPTACLE AT CABINET AREA PROVIDED FOR UNDER COUNTER REFRIGERATOR LIGHTING DISTRIBUTION: EXISTING FLUORESCENT LIGHTING TROFFERS TO BE RELOCATED TO PROVIDE 50 FOOT CANDLES OF ILLUMINATION AT WORK SURFACES AND 30 FOOT CANDLES AMBIENT(MEASURED AT 30" ABOVE FINISH FLOOR, TYPICAL) 5. CONTROLS DISTRIBUTION: CONTROLS FOR LIGHTING, HVAC, ALARMS OR SIMILAR, TO BE LOCATED NO MORE THAN 54" ABOVE FINISH FLOOR, ADJACENT TO ENTRY WAYS, AND DOORS, TYPICAL TELEPHONE DISTRIBUTION: TELEPHONE RECEPTACLES AND PULL WIRES TO BE PLACED ADJACENT TO DUPLEX RECEPTACLES IN OFFICES, CONFERENCE ROOM AND ADMINISTRATIVE AREAS EXISTING TELEPHONE TERMINUS TO BE REUSED (REFERENCE DRAWING) SITE DATA: PROJECT ADDRESS: 644 STRANDER BLVD TUKWILA WA 98188 CURRENT ZONING: TUC (CITY OF TUKWILA) PARCEL NUMBER: 000580 -0037 PROJECT TEAM: BUILDING OWNER: BC PARTNERS,LLC C/O MK PROPERTY SERVICES SNOQUALMIE WA 98065 425 -888 -2993 TENANT: UNITED STATES COAST GUARD ARCHITECTURAL urban solutions studio, IIc 1555 UNION AVE NE (66) RENTON WA 98059 206- 734 -4422 CONTACT: WARWICK ASHLEY GENERAL CONTRACTOR: EDI 12920 S.E. 95th Way NEWCASTLE WA 98056 425- 255 -5467 CONTACT: CHUCK LINDBERG WORK DESCRIPTION: INTERIOR TENANT IMPROVMENT TO EXISTING VACANT 2,500 S.F. (WORK AREA) STOREFRONT SPACE. NO EXTERIOR MODIFICATIONS TO THE BUILDING SHELL ARE PLANNED UNDER THIS SUBMITTAL. SIGN PERMIT WILL BE UNDER A SEPARATE SUBMITTAL. OCCUPANCY: GROUP B CONSTRUCTION TYPE: V -B PARKING PROVIDED: NO CHANGE MECHANICAL CONTRACTOR NORTHWEST AIRE SERVICES INC. PO BOX 66070 SEATTLE, WA 98166 (206) 241 -2657 VALUATION OF MECHANICAL WORK: $9,509.00 LEGAL DESCRIPTION: MEADER HENRY D -C #46 LOT 1 OF CITY OF TUKWILA SHORT PLAT NO 84 -31 -SS RECORDING NO 8501030748 SD SHORT PLAT DAF - POR NW 1/4 OF SEC 25 -23 -04 -BAAP ON WLY RJW LN OF WEST VALLEY HWY SR 181 AT A PT WCH BEARS S 81 -07 -31 W 50 FT FR C/L THOF AT HWY ENGR STA 160 +00 TH FR SD POB ALG SD WLY R/W LN S 12 -18 -30 E 250.45 FT TAP WCH BEARS S 81 -07 -31 W 35 FT FR C/L AT HWY ENGR STA 162 +50 TH S 05 -15 -06 E 112.35 FT TH TANGENT TO PRECEDING COURSE ALG ARC OF CURVE TO RGT RAD 50 FT & A C/A OF 86 -22 -37 ARC LENGTH 75.38 FT TAP ON NLY R/W LN OF STRANDER BLVD TH ALG SD NLY R/W LN TANGENT TO PRECEDING CURVE S 81 -07 -31 W 28.58 FT TH TANGENT TO PRECEDING COURSE ALG ARC OF CURVE TO LFT RAD 700 FT & C/A OF 19 -33 -22 ARC LENGTH 238:92 FT TH TANGENT TO PRECEDING CURVE S 61 -34 -09 W TO INTSN OF SD NLY RAN LN OF STRANDER BLVD WITH ELY BANK OF GREEN RIVER TH NLY ALG SD ELY BANK TO INTSN WITH SLY LN OF BOW LAKE P/L R/W 30 FT WIDE TH ALG SD SLY LNS S 87-12-48 E 194.01 FT TAP ON WLY RAN LN OF SD WEST VALLEY HWY TH ALG SD WLY RNV LN S 08 -52 -29 E 165.06 FT TO POB SHEET INDEX: A -1 COVER SHEET M -1 REFLECTIVE CEILING PLAN WITH MECHANICAL WORK M -2 FLOOR PLAN, FOR REFERENCE ONLY SEPARATE P REQUIRED FOR! REQUIRED 0 liotedhanicaf d>_tec#rlcal tumbing as Piping City of Tukwila IiJG DIVISION REVISIONS No changes shall rnadde to the scope of work without prior Tukwila Buildin avpro of 9 Division. e2 rri. E will require a new plan submittal ra -�'de additional plan review fees. NTERURBAN P` TO AVE S V� c�PO HWY 167 S TO 1 -90 TU SOUTHCENTER BLVD TU.. w cc w 0 0 RENTON KWILA PARKWAY cc uJ oa w 0 z STRANDER BLVD ITE VICINITY MAP SCALE: 1 1000' -0" 0 500' 1000' • ■ • ■ ROPERTY LINES TBACK FILE COPY ti No, approval is subject to errors and omissions. ^nstructiin documents does not au hhoF±he f any adopted code or ordinance. Rai Copy and City Of 1ikwiia ILDING DIVISION REVIEWED FOR CODE COMPLIANCE APPROVED XISTIN BUILDING LINE NOV 0 8 2011 City of Tukwila BUILDING DIVISION tot STRANDER BLVD SITE PLAN - 640 STRANDER BLVD, TUKWILA _ SCALE: 1 = 40' -0" WA RECEIVED OCT 25 2011 PERNICENTER 0 20' 40' NORTH Z * - °0� 0 4 g z u Qn c- Erno C) 0 0 Z o W, 0 U o Lo cn z Q ca ~ O 1-! . W Uz Cn Uv, • Lilo INTERIOR TENANT IMPROVEMENT w uJ / \ DATE REMARKS RY 1 10/18/11 PERMIT SUBMITTAL 1 , 1 1 1 1 . PLEASE CONSIDER THE ENVIRONMENT BEFORE PRINTING THIS DRAWING DRAWN BY: SM /GB CHECKED BY: WA JOB #' PHASE: DATE: 10/18/11 SHEET #: A -1 LSHEET OF 3 J HVAC General Notes: Codes Complete installation of the mechanical system shall be per the most current applicable building, mechanical, energy and fire codes, and regulations, as adapted by the City of Tukwila. Insulation/Lining /Sealant Notes As a minimum, comply with the thickness and types listed in the energy code enforced by the City of Tukwila. Balance and Commissioning Commissioning and Completion Documents to be in compliance with 2009 Washington State Energy Code, Section 1416. Air balance volume's at all supply and return outlets to be as indicated per sheet M/1. Occupancy Air Volume Minimum Occupancy air volumes per 2009 International Mechanical Code, Table 403.3, for Type Group "B" Occupancy. System design @ .06 CFM per square foot. Total space square footage = 2,500 2,500 x .06 = 150 CFM Occupancy Air provided via air side economizer set at the minimum open position. Sheet Metal Notes Reference:_SMACNA HVAC Duct Construction Standards, Metal and Flexible, Current Edition. Volume Dampers Provide an accessible, lockable, manual air volume control damper for each supply and return air opening. Thermostat Relocate and recalibrate the existing thermostat. Locate as indicated on sheet M/1, mount at five feet above finish floor. Scope of Work Removal of all existing interior ductwork and ceiling diffusers. ( Excluding Source Specific Exhaust and Fans.) ( Existing rooftop unit to remain at it's current location.) Installation of all new interior ductwork and diffusers per the mechanical drawings. Duct size's and air volumes as shown on plans. Provide and install a new factory built, 0 -100% air side economizer to the existing rooftop unit. New economizer to be compatible with, and to be of the same manufacturer as the existing RTU. Relocate (1) existing thermostat due to wall reconfiguration. Air balance system, perform completion and commissioning procedures as required. Existing Rooftop Unit Info Manufacturer Goodman Product • Packaged Heat Pump Model # GPH13660M212AB Total Cooling Capacity 57,500 BTU /h Total Heating Capacity 57,000 BTU/h System Design CFM 1,850 HVAC LEGEND SUPPLY AIR RETURN AIR OR CROSSOVER DUCT VOLUME DAMPER THERMOSTAT FLEXIBLE DUCT SHEETMETAL DUCT 1 R EXIST. VENT FANS TO REMAIN (TYP.) GC TO REPLACE EXIST. LIGHT FIXTURES OVER SINK WITH NEW UNITS (1 - 46W FLUOR. LAMP EACH - TYP. 2 LOC.) EXISTING GWB CEILING AT TOILET ROOM TO REMAIN - REPAIR AND REPAINT AS REQ'D. (TYP.) EXISTING 2' X 4' TROFFER FIXTURES RELOCATED IN EXISTING CEILING GRID AS SHOWN - CHANGE TO (4) T -8 TUBES (TYP.) TOTAL WATTAGE /FIXTURE: 96 WATTS MAX. EIR zoo F. TO REMAI b" P N (TYP.) ems, ALL NEW FULL - HEIGHT WALLS TO BE FRAMED TO UNDERSIDE OF EXIST. T -BAR CEILING (UNLESS NOTED OTHERWISE) - BRACE TOP PLATE TO EXIST. STRUCTURE PER CODE (TYP.) b A51-i L; OE S 6, 1.0 e t . b.1 `FhE ryc IS4-1+Ja '"gooF-'%p IDE POWER CREEN V TS. 85 iteirxt REFLECTED CEILING PLAN CATV CONNECTION FOR 0 DISPLAY PER TENANT RECESSED CAN FIXTURES W/ (1 EACH) 60W FLUOR. LAMPS - 3 LOCATIONS IN EXISTING CEILING GRID AS SHOWN (TYP.) NORTH GENERAL CONSTRUCTION AND ELECTRICAL NOTES, NOT APPLICIBLE TO MECHANICAL WORK, THIS SHEET. M IM 11 155 REVIEWED FOR CODE COMPLIANCE APPROVED NOV 0 8 2011 City of Tukwila BUILDING DIVISION RECEIVED OCT 25 2011 PERNITCENTER o eat 4 gio Pawl .r., PW CZ C.) cc • 4 4 w w CD zC n REMARKS BY 3/11 PERMIT SUBMITTAL 1 1 1 , PLEASE CONSIDER THE ENVIRONMENT BEFORE PRINTING THIS DRAWING 1 1 DRAWN BY: CHECKED BY: JOB #: PHASE: DATE: 10/18/11 SHEET #: SHEET L OF EXIST. DEMISING WALL TO REMAIN 3' -0' A- 22o G.C. TO REMOVE ALL EXISTING CARPETING \ r / \ / \ . / \ / \ / \ / EXISTING FLOOR PLAN _ SCALE: 3/16" = 1' -0 DOOR SCHEDULE # DOOR FRAME FINISH NEW/ EXIST'G. HARDWARE NOTES SIZE MAT'L. MAT'L 1 DBL. 3/0 X 7/0 STOREFRONT ALUM. ALUM. FACT. (E) EXIST'G. EXIST. 2 3/0 X 7/0 FLUSH STEEL STEEL PAINT (E) EXIST'G. EXIST. 3 3/0 X 7/0 FLUSH SC WD. STAIN (E) EXIST'G. EXIST. 4 3/0 X 7/0 FLUSH SC WD. STAIN (E) EXIST'G. EXIST: 5 3/0 X 7/0 FLUSH SC WD. WOOD STAIN NEW GROUP 1 6 3/0 X 7/0 FLUSH SC WD. WOOD STAIN NEW GROUP 1 7 3/0 X 7/0 FLUSH SC WD. WOOD STAIN NEW GROUP 2 8 3/0 X 7/0 FLUSH SC WD. WOOD STAIN NEW GROUP 3 HARDWARE GROUPS: NOTES KEY: RELEASE LOCKS PER USCG REQUIREMENTS GROUP 1 GROUP 3 (3 INSTALL ELECTRIC 1 1/2 PAIR PRIVACY SILENCERS GROUP 2 BUTTS 1 1/2 PAIR BUTTS LATCHSET PASSAGE LATCHSET SILENCERS DEADBOLT BUTTS LATCHSET 1 1/2 PAIR PASSAGE SILENCERS 10' .. III ..- NORTH POWER/COMM. KEY NEW CATS CABLE BOX @ 12" A.F.F.- NEW DUPLEX OUTLET @ 12" A.F.F. - EXIST. DUPLEX OUTLET TO REMAIN ALT. VOLTAGE 55'-1 1" +1- (E) RECRUITER #1 RECRUITER #2 RECRUITER #3 t ^e::e::1 ::e: :e::e::e::e: :a::e::r: :e::. ::e::e::o:: ::i::I: I ::I::e: :e::o::e:: VP Q _ :ii: RECRUITER #4 RECRUITER #5 :o::e::ie: ::e:: : :::::::: ::ae::e::e: TYP. @ CHAIR RAIL .. .. r/L, /iiiii i///// E 111 �! will/ e= ISIS i► 11111 �1- 1 1 �� MAIUCOPY ®1 '� 1ie N ;w.f./X. / / / / / / / // / / / /. % ///://///// / / / / / / / / / /. 4 v 7. / ' l /. : `/. : /. . /. : /. : : /. . /. . '/. : '/- v/7"; ' ® ®Mili■ ®II ■��®ISrMEM. 1 _ ��i�■ii�11 AM= •R 1 gr- ■r e - . 1% RECRUITER #7 M 11111 I 1 1 I' 1; 11► tz-wb J. OFFICE (XPO) RECRUITER #6 CONF. 14'- 113 % "(E) 10' -2" +/- EXIST. FLOOR OUTLET TO REMAIN NOTES: 1. ALL EXISTING OUTLETS ARE ASSUMED TO BE 110V, UNLESS OTHERWISE NOTED. 2. ELECTRICIAN TO VERIFY ALL CLEAN POWER REQUIREMENTS WITH TENANT PRIOR TO COMPLETION OF WORK. PROPOSED :FLOORPLAN SCALE. 3/16" = 1' -0" 1 x 6 HDF CAP (PAINTED) +78" ABOVE FINISH FLR. NORTH 5/8 x 3 HDF TRIM (PAINTED) WALL CAP DETAIL SCALE: N.T.S. +39" ABOVE FINISH FLR. 5/8 x 5 CHAIR RAIL (PAINTED) WALL TYPE (PER PLAN) CHAIR RAIL DETAIL SCALE: N.T.S. 5' M 155 WALL TYPE KEY A B WALL TYPE (78" TALL): > 5/8" GWB > 3 5/8" MTL STUDS @ 16" O.C. > 5/8" GWB WALL TYPE (42" TALL): > 5/8" GWB > 3 5/8" MTL STUDS @ 16" O.C. > 5/8" GWB * *CHAIR RAIL (TYP. WHERE SHOWN) WALL TYPE (FULL HGT. TO T -BAR): > 5/8" GWB >3 5/8" MTL STUDS @ 16" O.C. > 5/8" GWB ** ACOUST. INSUL. (TYP. WHERE SHOWN) WALL TYPE > EXISTING FRAMED WALL TO REMAIN 10' 1 1 1 1 REVIEWED FOR CODE COMPLIANCE APPROVED NOV 0 8 2011 City of Tukwila BUILDING DIVISION RECEIVED OCT 25 2011 PERMITCENTEF DATE REMARKS BY 10/18/11 PERMIT SUBMITTAL I I I 1 I PLEASE CONSIDER THE ENVIRONMENT BEFORE PRINTING THIS DRAWING 1 1 1 1 DRAWN BY: SM/GB CHECKED BY: WA JOB #: PHASE: DATE: 10/18/11` SHEET #: M -2 LSHEET OF