HomeMy WebLinkAboutPermit M11-159 - WESTFIELD SOUTHCENTER MALL - GREASE TANKS AND PIPINGWESTFIELD MALL
2800 SOUTHCENTER MALL
M11-159
Parcel No.:
Address:
CiyPof Tukwila
•
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Inspection Request Line: 206 - 431 -2451
Web site: http: / /www.TukwilaWA.gov
MECHANICAL PERMIT
9202470010
2800 SOUTHCENTER MALL TUKW
Project Name: WESTFIELD MALL
Permit Number: M11 -159
Issue Date: 12/22/2011
Permit Expires On: 06/19/2012
Owner:
Name: WESTFIELD PROPERTY TAX DEPT
Address: PO BOX 130940 , CARLSBAD CA 92013
Contact Person:
Name: JIM HODGE
Address: 5795 S 130 PL , SEATTLE WA 98388
Email:
Contractor:
Name: PORTLAND MECHANICAL CONTRS
Address: 2000 SE HANNA HARVESTER DR , MILWAUKIE OR 97222
Contractor License No: PORTLMCO24KA Expiration Date: 02/27/2012
Phone: 206- 243 -7387
Phone: 503- 656 -7400
DESCRIPTION OF WORK:
REISSUANCE OF EXPIRED PERMIT M11 -023
INSTALL (3) GREASE TANKS (USED COOKING OIL RECYCLING HOLDING TANKS) AND
ASSOCIATED 2" STEEL PIPING.
TANK 1: SECOND LEVEL, EAST SIDE TRASH/RECYCLE ROOM
TANK 2: LEAST SIDE LOADING DOCK
TANK 3: SECOND LEVEL, WEST SIDE TRASH /RECYCLE ROOM
Value of Mechanical: $7,000.00
Type of Fire Protection: UNKNOWN
Electrical Service Provided by:
Permit Center Authorized Signature:
I hereby certify that I have read and
governing this work will be compli
ex
wi
The granting of this permit does not p -s
construction or the performance of work.
back of this pe
Fees Collected: $269.31
International Mechanical Code Edition: 2009
Date:
ed this permit and know the same to be true and correct. All provisions of law and ordinances
, whether specified herein or not.
e to give authority to violate or cancel the provisions of any other state or local laws regulating
I am authorized to sign and obtain this mechanical permit and agree to the conditions on the
Signature: /�' � ,4f Date: 01.12-/I k
Print Name:
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
doc: IMC -4/10
M11-159 Printed: 12 -22 -2011
PERMIT CONDITIONS
Permit No. M11 -159
1: ** *BUILDING DEPARTMENT CONDITIONS * **
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center
(206/431- 3670).
4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
5: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
6: Manufacturers installation instructions shall be available on the job site at the time of inspection.
7: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila
Building Department (206- 431- 3670).
8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206- 431 - 3670).
9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
arty violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
10: ** *FIRE DEPARTMENT CONDITIONS * **
11: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the
following concerns:
12: Ensure that all penetrations are appropriately sealed.
13: Mount a Class K rated portable fire extinguisher within 30 ft. of each grease tank.
14: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or
brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation
instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so
that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross
weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the
floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4
inches (102 turn). (IFC 906.7 and IFC 906.9)
15: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot
be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6)
16: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that
indicates the month and year that the inspection was performed and shall identify the company or person performing the
service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge
procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the
inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these
required surveys. (NFPA 10, 4 -3, 4 -4)
17: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and
#2051)
18: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of
such condition or violation.
doc: IMC -4/10
M11-159 Printed: 12 -22 -2011
19: These plans were revieS by Inspector 511. If you have any question ase call Tukwila Fire Prevention Bureau at
(206)575 -4407.
doc: IMC -4/10
M11-159 Printed: 12 -22 -2011
CITY OF TUKWIL
Community Developmet Turtment
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http: /,'www.TukwilaWA.gov
MECHANICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *please print **
King Co Assessor's Tax No.:
Site Address: Z 00 So✓4I4 cc,✓ rf /L I(
Tenant Name:
Suite Number:
Name:
74.I)' P✓o
Address: po o O� c140
City: CA ')Lc4
State: Cl
Zip
4• 'NCR a ! E#31 �` j trgs a '
Name: --;.:1--,71$4 tom —
Address:" 1
City: .e,A[G State: h./4 Zipiw ,-
Phone: .01.0-1,<1 - 7 4f7 Fax:
Email: ,- QQ J '• j
�l i404„ a 'xk,40,I.3MO�if,,e, ,G 044
Valuation of project (contractor's bid price): $ `11000
ck-c_e — re,
pp c OU F•� v d l lGG jLG�
q�k — 55s_on/ck Lucy I ` :44 'c,)
Describe the scope of work in detail:
Use: Resi
ential: New
Commercial: New
Fuel Type: Electric
New Tenant:
Floor: /41--
❑ Yes].. No
Company Name: 0(1) j T' Nr" cA.
Address:
Zo 0 0 s� itc,A,,,a, I4 fJ 4 t� Dr,,
City: State: Zip
:97 tdc.,tik.� ►Z ?z �
Phone: co 5 - 66-6 7400 Fax:
Contr Reg No.: pvel 4A4 co z4 K/11- Exp Date: ziL� J,"
Tukwila Business License No.:
r (�
i1,Stlti -;o( Gjtl ,`lrrX
,;4: / 1)0 I J,>v
t ,ryS�
r7-I G rot
1 P ✓L L al/ w1,15.1-4e
Replacement
Replacement
Gas ❑
Other:
H: \Applications\Forms- Applications On Line \2011 Applications\Mcchanical Permit Application Revised 8 -9 -11. docx
Revised' August 2011
bh
,t
Z ' s ce,
e`etif roam
Page 1 of 2
Indicate type of mechanical work being ins �lled and the quantity below:
7nit_Type
Qty'..
Furnace <100k btu
Furnace >100k btu
Floor furnace
Suspended/wall /floor
mounted heater
Appliance vent
Repair or addition to
heatlrefrig/cooling
system
KK,
Air handling unit
J
<10,000 cfm
• . , ^ Unit Type.
: OW:-
Air handling unit
>10,000 cfm
Evaporator cooler
Ventilation fan
connected to single duct
Ventilation system
Hood and duct
KK,
Incinerator — domestic
J
Incinerator —
comm/industrial
•
YUnit Type
r Qty
Fire damper
Diffuser
Thermostat
Wood/gas stove
Emergency generator
Other mechanical
equipment
KK,
I '
6—YemG (O A)
J
VBoile /Compressor
0 -3 hp /100,000 btu
3 -15 hp /500,000 btu
15 -30 hp /1,000,000 btu
30 -50 hp /1,750,000 btu
50+ hp /1,750,000 btu
Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the permit center to comply with current fee schedules.
Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing
and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING ER A/ HORIZED AGENT:
��
Signature: %" • �
Print Name:
Mailing Address: 7C1 'S , 13041^ ? L 1-
H :\Applications\Forms- Applications On Line \20I I Applications\Mechanical Permit Application Revised 8- 9- 11.docx
Revised: August 2011
bh
Date: \ \.'0A1
Day Telephone: Z01,— 7gS -41
City State Zip
Page 2 of 2
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206-431-3665
Web site: http: / /www.TukwilaWA.gov
RECEIPT
Parcel No.: 9202470010 Permit Number: M11 -159
Address: 2800 SOUTHCENTER MALL TUKW Status: APPROVED
Suite No: Applied Date: 11/10/2011
Applicant: WESTFIELD MALL Issue Date:
Receipt No.: R11 -02771
Initials: JEM
User ID: 1165
Payment Amount: $107.73
Payment Date: 12/22/2011 08:53 AM
Balance: $0.00
Payee: BAKER COMMODITIES, INC.
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Check 146362 107.73
Authorization No.
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
MECHANICAL - NONRES
000.322.102.00.00 107.73
Total: $107.73
doc: Receiot -06 Printed: 12 -22 -2011
-4A1
INSPECTIONrNO.
INSPECTION RECORD
Retain a copy with permit
CITY OFTUKWILA BUILDING DIVISION G
6300 Southcenter Blvd., #100, Tukwila. WA 98188 e.. (206) 431 -3670
Permit Inspection Request Line (206) 431 -2451
Mt -1 s9
PERMIT NO.
Project: r
it jP.-S ' ` �..� 'fit „-[J
Type of Inspection:
* xi ,11-x--
Address 0 a � 4 _e 4 f
DatRallejGiA
prc a
Special Instructions:
J
A
n ✓ ( e _ �, v y
Pte
Date Wanted:
2 '11—
1 .Z.
aa.m.,
P.m.
Requester:
Approved per applicable codes. D Corrections required prior to approval.
COMMENTS:
ire.-- T)14Krf 1.11 2 ` `
re
prc a
1 -z-1 e41
irk`- Ai\pYe
*Mso A$ pry J -0 re_-_LsC° c
/
n A-<< 3
i
‘ r‘), -
%
'
Inspector:
Datey
REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to'schedule reinspectioh.
INSPECTION RECORD
Retain a copy with permit
PERMIT NUMBERS
• CITY OF TUKWILA FIRE DEPARTMENT
444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407
Project:
1./J`SI (Ye)) WV tZ.,
Type of I pection:
Meck
Address: ., �/—
Suite #:
Contact Person:
-Z (d" Padre.
Special Instructions:
Phone No::
INSPECTION NUMBER
•
']Approvediper applicable codes.
Corrections required prior to approval.
COMMENTS: '
Sprinklers: •
Fire Alarm:
Hood & Duct:
Monitor:
Pre -Fire:
Permits:
Occupancy Type:
3 &veil, se
►t) k. s
1v5 � L_1�
_6---4). c
0
. 9
.y 7
r+--
Needs Shift Inspection:
Sprinklers: •
Fire Alarm:
Hood & Duct:
Monitor:
Pre -Fire:
Permits:
Occupancy Type:
Inspector: %
Sa--_
Date: 2 / /W /Z.-._
Hrs.:
1
n $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from
the City of Tukwila Finance Department. Call to schedule a reinspection.
Billing Address
Attn:
Company Name:
Address:
City:
State:
Zip:
Word /Inspection Record Form.Doc
6/11/10
T.F:D. Form F.P. 113
•1
• '1
•
•�'r'qp . z •. ,V4,- ..59T - _ : vim-
1
INSPECTION NUMBER
IN PECTION RECORD
Rtain a co PY with permit
PERMIT NUMBERS
CITY OF TUKWILA FIRE DEPARTMENT
444 Andover Park East, Tukwila, Wa. 98188 206 - 575 -4407
Project:
() 05k e I) C1/14'LL
Type of Inspection:
eli fir►) K
Address: ?_so e.„
Suite #:
S 11,1 M-t z_
Contact Person:
Special Instructions:
Permits:
Phone No.:
Approved per applicable codes.
,Corrections required prior to approval.
COMMENTS:
Sprinklers:
Fire Alarm:
Hood & Duct:
Monitor: N
Pre -Fire: . -
Permits:
Occupancy Type:
1t P
('Srro)(It ( 8145 _
1'-t- 111Yr-
: -'
i Ai w) 4,-, aLer S e...,
ap 13
r
-
,1
o
i
Needs Shift Inspection:
Sprinklers:
Fire Alarm:
Hood & Duct:
Monitor: N
Pre -Fire: . -
Permits:
Occupancy Type:
Inspector:
row
Date:
2-/g97/(
Hrs.: 1
$100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from
the City of Tukwila Finance Department. Call to schedule a reinspection.
Billing Address
Attn:
Company Name:
Address:
City:
State: 1 Zip:
Word /Inspection Record Form.Doc
6/11/10
T.F.D. Form F.P. 113
•
•
•�
.ti
s
.!
•
REVISIONS
No changes shall be made mml b de to the scope
of work witl-tout DI royal of
Westfield's used oil recycling tanks inside the Westf Id Shoppirtgi9ent iiD11 I ►.
!%ion.
NOTE: R2visionc will require a new plan submittal
and may include additional plan review fees.
Grease Tank #1 is in the "Second level" East Side trash /recycle room. This tank is plumbed through the
floor to the loading dock room below on the in floor. The plumbing runs to the east wall and down to
floor level. Then along the east wall to the end of the loading dock and is valved and capped. This is
where we connect and empty the tank.
Grease Tank #2 is on the "First level" East side loading dock. This tank is plumbed directly from the tank
and down the east side wall parallel with the above tank. This line is also valved and capped on the end.
This is also where we connect and empty the tank.
Grease Tank #3 is in the "Second level" West Side trash /recycle room. This tank is plumbed through the
floor to the loading dock room below on the ft floor. The plumbing runs to the west wall and down to
floor level. Then along the west wall to the end of the loading dock and is valved and capped. This is
where we connect and empty the tank.
The pipe that is used is 2 inch steel. The floors were "slab imaged" before core drilling to ensure the
slab was free of cables or utilities. The holes in the floor have been sealed with "fire barrier" sealant. All
three tanks are secured to the closest wall. These tanks are only used to hold used cooking oil. We then
picicup the oil and recycle it.
Permit N®.,
PIP- r ^!new approval is subject to errors and omisslons.
t,. . 7.! of construction documents does not authorize
t; : r:: . i a adopted code or ordinance. Receipt
a` i- pploveCa py -i .. • ∎ I,. ns is acknowledged:
kk
Date: MOW
City Of 1UkwIla
BUILDING DIVISION
REVIEWED FOR
CODE COMPLIANCE
APPROVED
NOV 2 1 2011
AT-
City of Tukwila
UILDING DIVISION
MEWED
NOV 10 2011
T
�./ i -- ( to;7
1
nd Level (East Side) Grease Tank
i
FC5
668sf
718sf
T
TRASH/
RECYCLE
ROOM
1St Level Great Tank Extraction Pipe :)
H
H
1 GE
FIRE
RISER
ROOM
METERS
s
•
JC
xIi
3
REVIEWED FOR
ODE COMPLIANCE
APPROVED
NOV 212011
City of Tukwila
BUILDING DIVISION
nd Level West Side Grease Tank
u4
1st evel Great Tank Extraction Pipe w4.40
RR
3
1
hum
TR 3
REVIEWED FOR
CODE COMPLIANCE
APPROVED
NOV 212011
City of Tukwila
BUILDING DIVISION
DUKES •
FIRE
=RISER t
ROOM
11 •
,II _ECT.y[ S'
MIERS A
TM
.IodeI 4280 -NA
CONSTRUCTION AND FEATURES
• Heavy gauge aluminum exterior.
• Free standing, 42 in. diameter x 80 in. height.
• 2650 lb/353 Gal. waste shortening capacity.
• Remote located control panel with power indication.
• Level indicators with safety overflow protection.
• UL, UL Sanitation (NSF) Listed (US and Canada).
• Suitable for Direct - Plumbed•, Remote - Plumbed• or Caddy systems.
• Easy to access and service components.
• One year warranty on all parts and components.
• Worldwide delivery and installation available.
• Tank may be located indoors or outdoors.
• Immersion heater maintains contents in liquid form.
BENEFITS
• Minimal or no handling of hot waste shortening.
• Insurance and Workman's Comp savings.
• Less employee down time.
• Labor savings and greater employee safety.
• Cleaner grounds and image.
• Waste oil of higher value to collection companies.
• Avoid pollution fines.
nstallation and:Operating.5pecificationr:
Model
Power Requirements
Installation Space Requirements
Shortening Capacity
Shipping Weight
Documentation
Warranty
4280 -NA Containment Tank
110V15 A
43 in. Ix43in.wx81 in.h
2650 lb (approx. 353 gal)
460 Ib (tank only on pallet)
Installation guide, Operating guide
1 year parts and labor
Frontline International, Inc. • 95 16th Street SW Barberton, Ohio
Tel: 330 -861 -1100 • Fax: 330- 861 -1105.
Web: www.frontlineii.com • Email: info @frontlineii.com
REVIEWED KA
4 9DE COMPLIANCE
APPROVED
NOV 21 2011
City of Tukwila
BUILDING DIVISION
US
ter ,ModeL3'-
CONSTRUCTION AND FEATURES
• Heavy gauge stainless steel exterior.
• Free standing, 30 in. diameter x 72 in. height.
• 1500 Ib waste shortening capacity.
• Control panel with power indication.
• Level indicators with safety overflow protection.
• UL, UL Sanitation (NSF) Listed (US and Canada).
• Suitable for Direct - Plumbed', Remote-Plumbed' or
Caddy systems.
• Easy to access and service components.
• One year warranty on all parts and components.
• Worldwide delivery and installation available.
• Insulated exterior tank enclosure available.
BENEFITS
• Minimal or no handling of hot waste shortening.
• Insurance and Workman's Comp savings.
• Less employee down time.
• Labor savings and greater employee safety.
• Cleaner grounds and image.
• Waste oil of higher value to collection companies.
• Avoid pollution fines.
SIjF �?i.;`,.. t' i' U�, n. z+:, i�f 1. i�,•' ff, ��:.m 7 .:u:iA'- `�C. "':fi9i::t,yY�:iJ'L: ���ti.Y: "aM7•'".i���ffi �`''�i,�i �fii:�
Installation and Operating ]Specification
sf�,,,�,Y
Model
Power Requirements
Installation Space Requirements
Shortening Capacity
Shipping Weight
Documentation
Warranty
3072 -NA Containment Tank
110V 15 A
31 in.I x31 in.wx82in.h
1500 Ib (approx. 200 gal)
400 Ib
Installation guide, Operating guide
1 year parts
Frontline International, Inc:.,95.16th Street SW. Barberton, Ohio 4
Tel: 330 - 861 -1100 • Fax: 330- 861 -1105
Web: www.frontlineii.com • Email: info @frontlineii.com
REVIEWED,,ZQc
CODE COMPLIANCE
203 APPROVED
NOV 21 2011
City of Tukwila
BUILDING DIVISION
FILE COPY
Frontline International Inc.
Cooking Oil
Management Systems
REVIEWED FOR
CODE COMPLIANCE
APPROVED
NOV 2 1 2011
VV(2-
City of Tukwila
BUILDING DIVISION
OilCareM
Ml1I59
Frontline International Inc. - Confidential
RECEIVE
NOV 10 2011
PERMIT CENTER
FII
s 3s
Presentation Contents
• Company Overview
- Background and Experience
- Customer Base
- Service and Installation Network
• Typical Current Existing Situation
- Health and Safety Concerns
- Environmental Concerns
- Store Image
• Equipment Solutions
- Waste Oil & Grill Grease Systems
- Fresh Oil Systems
- Filtration
• Benefits
( OiICare -
Frontline International Inc. - Confidential
Company Overview
• Background and Experience
— US Manufacturer specializing in the design and manufacture of
commercial kitchen equipment for the last 9 years.
— All products are focused on Cooking Oil Management (Waste,
Fresh and Filtration) and support health /safety, environmental and
green (renewable fuels) initiatives.
— Products are approved by many QSRs, Institutions, Government
Agencies, Universities and Super Market Chains.
— All Frontline Systems are designed to be upgradeable to the latest
technology assuring equipment can grow and be flexible with
plans and budgets.
— All Frontline International products are tested and approved to
Underwriter Laboratories (UL), NSF, CSA and CE Standards and
Specifications.
— Proven experience with over 15,000 installations worldwide.
— Further details are available at www.frontlineii.com
• Customer Base (condensed)
— Burger King (Global), Wendy's(Global), Jack In the Box (Corp.),
Giant Eagle, Kroger, Wilco Hess along with many others.
• Service and Installation Network
— Worldwide distribution and installation capabilities supported by a
network of service and parts specialists.
— Experience with large and small scale rollouts to include turnkey
solutions.
C
OilCare°
Frontline International Inc. - Confidential
TYPICAL EXISTING SITUATION
• Cooking Oil Management programs may have
not yet implemented, including but not limited
to:
• Filtration Procedures
• New Oil Changes /Protocols
• Waste Oil Handling Procedures and Safety to prevent spills,
burns, slips and falls
• Kitchen Cleanliness
• Exterior Safety, Cleanliness and Odors (corral)
• A corporate approach toward cooking oil
management has not yet been addressed.
• Various stores have implemented an array of
waste oil systems not consistent with each
other or corporate directives.
OilCareu
Frontline International Inc. - Confidential
TYPICAL EXISTING SITUATION
Spilled
oil in parking lot and around bin is a hazard and
creates environmental issues with manual discarding
practices. In addition, waste cooking oil stored in bins is
prone to odors and can attract rodents.
OilCare-
Internal fry areas may use
manual buckets or
shortening shuttles that
are prone to health and
safety issues.
Frontline International Inc. - Confidential
Equipment Overview
OilCare-
Frontline International, nc.
ENGINEERED SOLUTIONS FOR COOKING OIL MANAGEMENT.
Fresh 00 System
Fresh Oil Pump Station
Waste 00 System
Waste Oil
Pump
Station ..
Direct
Plumbed
Filtration
System
i ortable.,
Filter "then
4OilCare
Grill
Grease
Transport
Caddy
Frontline International Inc. - Confidential
EQUIPMENT
OVERVIEW
• Waste Cooking Oil and Grill Grease Equipment
• Caddy System (good)
• Standard
• Remote
• Outside
• Waste Oil Pump Station System (better)
• Standard
• Remote
• Direct - Plumbed System (best)
• Standard
• Outside
• Grill Grease System (optional)
• Fresh Cooking Oil Handling Equipment
• Rack System
• Standard Bulk System
• Outside Bulk System
• Cooking Oil Filtration Equipment
• Caddy with Filter Upgrades
• Filter Machine
(4�ilCare
Frontline International Inc. - Confidential
Caddy System (Good)
Basic Operation
• Standard Caddy
System
• Remote Caddy
System
• Outside Caddy
System
/ ammo toe
WASTE OIL COUECTION LINE
WASTED:0KM OIL
TM&
(VAISOUS MODELS)
NOTE. MR IIISTALLATION
DUMB. REVIEW
INSTRUCTION MANUAL
PROVIDED SY FROM)
AREMATIONAL,
CONIRC4. PANEL
r STATION
\
WASTE COOKINO
i+ CADDY
• .<77277.0 ::" • 77W/,,..
STANDARD CADDY SYSTEM
WASTE COOKING Oil
TWI
(VARIOUS WOOS)
NOTE FOR SASTALLATION
MAWS REINEW
aisraucTtooi MANUAL
PROVE/MY FROMM
INTEMATIONAL INC-
REMOTE CADDY SYSTEM
WASTE OA UNE PROM
COL REMOTE INLET le TANN \
/WM
PONE
_11 \-1
NOTIL FON
OISTAU.ATION
DETAILS, REVIEW
ONTTRUCTION
MANUAL PROVIDED
Ov FRONTLINE
INTERNATIONAL.
TAN A MANE !
WA8111 COOKINO
TISK
(OM= MOWN
=IRO. p
REMOTE INLET
LL_ WAOIEDL
CEDY
_5;44
--....
4l0 I.88 . \
..-
r.....
1 1
i I
I
COMMIE. PANEL
NUR
1 WASTE COOKING ON
CAME,
! (VANEELN WOMEN
oursmE CADDY SYSTEM
Frontline International Inc. - Confidential
FII
Waste Oil Pump Station (Better)
Basic Operation
• Waste Oil Pump Station
— Prerequisites
• Frontline Direct-Plumbed Tank
• Standard Pump Station System
aro
ripiA
WARTS Oa. PUMPOTATION
NOTE. FOR INSTALLATION
DaTA11.0. REVIEW
INSTRUCTION MANUAL
PROVIDED OYFRONRINE
INTERNATIONAL DM
WASTE OIL LIKE FROM PLR.
STAMM TO TANK
SUCTION VIAND
[7:7wzi ii2Z,L747 7Z1Z-LMTM
STANDARD PUMP STATION SYSTEM
• Remote Pump Station System
.011Carew
COON° UM
WARM Oil PUMPSTATION-4^-
ON/OFF
SWITCH
NOM FOR INSTAUATION
perms, RE1Aew
OISTRUCTION MANUAL
PROVIDED Eff FROMM
INTERNATORN..
WAVE OIL Me FROM PUMP
STATION TO TANK
PPS GNAWS
RISIA7TE OUTLET
SUCTION WAND
177 Z/7
REMOTE PUMP STATION SYSTEM
Frontline International Inc. - Confidential
FII
Direct - Plumbed (Best)
Basic Operation
• Direct - Plumbed to Fryer
— Prerequisites
• Built -in filtration on the fryer
• Rear waste oil disposal kit from fryer
manufacturer
• Frontline Direct - Plumbed Tank
• Standard Direct Plumbed System
C1:Fl1OLS0
a.
INAKIS OIL
OOLLEC710N
LINE
VUSIl CC010N/01.
TANK
EAKEO A IIDw2T
TANK INLET
COKTRa PA18
WASTE TEL UN& raw FRYER TO
TANK
NOTE FOE INSTALLATION
OlMll, away
N&RL/CTLON WARM
PROVIDED BY FRONTLINE
INTERNATIONAL NO.
STANDARD DIRECT PLUMBED SYSTEM
• Outside Direct Plumbed System
GG
OilCareu
CQILQTTOI PORT
TANK Ol&T
TASTE OCCKNOCR
TANK
10171/00 NOOOJI)
HASTEC . LINE:RONI FRYER TO
TANK
NOTE FOR NarALUTp1
DETAIL% REVIEW
0I31181CRpi HANNA.
PROVIDED BY stototoe
INTERNATIONAL. OKI
%Il
1■
OUTSIDE DIRECT PLUMBED SYSTEM
Frontline International Inc. - Confidential
Grill Grease System (option)
OiCarer
CONSTRUCTION AND FEATURES
• 100% Heavy Stainless Steel Construction.
• Safe silicone heater to prevent congealing.
• Swivel front and rear casters with brakes.
• Extra large grill sediment basket.
• Power Switch and break away power cord.
• Easy quick connect fittings.
• 110v industrial 1 /2HP motor.
• 5 gallon per minute pump.
• Easy to clean seamless construction.
• UL, UL Sanitation (NSF) Listed.
• 1 year warranty parts and labor.
BENEFITS
• No manual handling of grill grease.
• Simple system fits under grill drains.
• Insurance and Works Comp savings.
• Grill grease drains Into top opening throughout the day.
• Less employee down time.
• Labor savings and greater employee safety.
• Cleaner grounds and image.
• Avoid pollution fines.
Model
Power Requirements
Installation Space Requirements
Shortening Capacity
Shipping Weight
Documentation
Warranty
CE
Frontline International Inc. - Confidential
LS -1 -6000
110V15A
16.25 in. I x 17.25 in. w x23.50 in. h
60 lb (approx. 8 gal)
72 lb on pallet 130Ib
Installation guide, Operating guide
1 year parts and labor
US
Fresh Oil Dispensing Options
• Standard Packaged Oil
— Prerequisites
• Bag in box or jug /jib oil
• Frontline fresh oil pump station
— Packaged oil is connected with manifold kit
— Fresh oil pump station is mounted in storage
area
— Outlet fitting is mounted by fryers
— Removable hose and trigger wand dispenses oil
unless connected to auto -fill style fryer
• Bulk Tank for Fresh Oil (limited by distribution)
— Prerequisites
• Bulk style system
• Frontline fresh oil pump
— Tank is located in rear of store with flexible
plumbing from tank to fresh oil pump station
— Additional flexible plumbing is run from fresh oil
pump station to fryer location
— Removable hose and trigger wand dispenses oil
unless connected to auto -fill style fryer
C4OiOCareTu
Frontline International Inc. - Confidential
Fresh Oil Dispensing Options
Rack System
ROM (MASAO RATKO
_J 011.11111.061 RUN 10
• MO Ottral
fRair1011.1.1NE MOM OAP
ITTATICM TOOT/TWO
;••••
natjzzATE.zar
MOM OSTAITAIKO
OLTUJI.O,PEVIVO
TAAMOU.
SOOVITIEDINFROMRDO
OROOVOIONAL.
ROI was
, mac..curu,
ZEZ/ff= E,727=STY'&7;z77_702
RACK SYSTEM
Standard Bulk System
Outside Bulk System
Oil Care-
FOISHCO. SAY POOH
MAN Oa. LOC MOW TANK TO
.fl Am
MOTO 1
. MUM OXXOTTICTI.
gursce.ccom
ROM
, • CCM
MOM
PUMP
OTAITON
TO
OUTUNT
MT1100.1111
WOE 1,041141TWATICA
MAUI, REAM
NOTIAUCTOT WAAL
PIONYZO VI MOSCOW
INTOOIATKOAL. TOO
1
MOH 011. OWLS, AVIA
ocuriumvu MiCATEIN
OUTSIDE RUUC SYSTEM
Frontline International Inc. - Confidential
FII
Cooking Oil Filtration
Equipment
Caddy Upgrade
'Extend
Convert any Frontline Shortening
Transport Caddy into a state of the art
heavy duty cooking oil filtration system.
Designed to operatewfth anycommercial fryer,thi s powerful
and easy to use filtration system is an extremely functional
extension to any frying system.With the high capacity
filtration you quickly benefit through longer and more
consistent shortening life, as well as by simply wasting
shortening less often.
Disposable paper media filter
Disposable Carbon Media Filter
OilCare-
Re- useable stainless steel filter
j atityA■ue4n was in
OILCARE FILTRATION SYSTEM
• 100% Heavy gauge Stainless Steel Construction.
• Simplicity is key. Easy to assemble. Easy to use. Easy to dean.
• Available with disposable paper, or re- usable stainless steel
elements.
• Kit can be factory assembled or can be easily converted on site.
• Convert the 1 OSS- NA,16SS -NA or the 20SS -NA transport caddy.
• Heavy duty stainless steel mesh pre - filter crumb catcher basket.
• Specially designed non "shearing" 5 gpm pump with a 110v 15a
1/2 HP motor.
• Seamless integration with Frontline containment systems.
• Power switch and safety "break away" power cord.
• Stainless steel refill (wash down) nozzle.
• Easy to use quick disconnect fittings.
• Easy to clean "seamless "construction.
• UL and UL Sanitation (NSF) Listed.
• 1 year warranty on all components.
Models
Documentation
Ship Wt Kit Only
Ship Wt w/1 0SS -NA'
Ship Wt w /16SS -NA"
Ship Wt. w /20SS -NA"
Frontline International Inc. - Confidential
Specifiratlons
FILTER- KIT -FP
FILTER-KIT-FS
FILTER - KIT -FC
Conversion & Operating Instructions
50 Lbs.
170 Lbs.
210 Lbs.
220 Lbs.
1
Cooking
Oil Filtration
Equipment
Filter Machine
B
o a
•
1
Dimensions for LS•1-60
130
Dimensions for LS.1.03
COilCareM
oaei
Series
Model LS -1 60# and 85# filter machines are a stand alone filter
which utilizes the virtually all types of Filter Media and shortening
polishing prod uctscurrentlyavailable .Afilter machine'seffectiveness
is based on the filter media used.The LS -1 SERIES Filter Machine
incorporates all of the finest filtering media in the industry.
ain°.Features
• Simple to operate
• Removable pan for easy cleaning
• Sturdy construction and high quality components for long life
• Stainless Steel Construction
• Safety no- splash nozzle
• Compact for easy storage
• Can be configured to utilize virtually any specified filter media
Weight 72 Lbs.
Overall Dimensions 6.75' wx 23.75 "dx 27.25 "h
Pan Height 11.75"
Total Pan Capacity 163 cubic 166101 17.1 gallons 60 Lbs. of
oil or 7.7 gallons
Pump/Motor Haight SE Hot OD Hub mount Pump
Capacity 4,6 GPM at 1750 RPM. 1 /3 HP capacitor
start, Rotary Gear, positive displacement
pump, 115 volt, 6.2 amperes, 60•cycle
motor
Electrical Plug Standard 3 wire. 110 volt plug -In cord
Dlmerislons fof
Weigh 75 Lbs.
Overall Dimensions 1675 wit 295'd x 27.25'
Pan Height 11.75
Total Pan Capacity 2.1 cubic feet 0116.2 gallons 85 Lbs. of oil
or 10.9 gallons
Pump/Motor Haigh SE Hot 011 Hub mount Pump
Capacity 4.6 GPM at 1750 RPM, 1/3 HP, capacitor
start, Rotary Gear, positive displacement
pump 115 volt, 6.2 amperes, 60-cyde
motor
Electrical Plug Standard 3 wire, 110 volt plug -In cord
Frontline International Inc. - Confidential
Benefit Summary
• Provide a much safer store by reducing
possibility of burns, slips, and falls.
• Substantial labor savings from current waste oil
procedure to Frontline automated system.
• Create a standard protocol for cooking oil
management across all stores for consistent
health and safety practices.
• All existing Frontline waste oil equipment may
be upgraded versus removing and discarding
perfectly good working systems.
• Fresh oil dispensing may be added at any store
at any time versus requiring both fresh and
waste to be installed at the same time.
• Support green efforts by utilizing equipment that
assists in recycling waste cooking oil into
renewable fuels.
(a OilCare-
Frontline International Inc. - Confidential
•
PE T tra r
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: M11 -159 DATE: 11 -10 -11
PROJECT NAME: WESTFIELD MALL
SITE ADDRESS: 2800 SOUTHCENTER MALL
X Original Plan Submittal Response to Incomplete Letter #
•Response to Correction Letter #
Revision # After Permit Issued
DEPART ENTS: q-(
ing n
Public Works ❑
Fire Prevention
Structural
Planning Division
Permit Coordinator
n
1
DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 11 -15-11
Complete
Incomplete
n
Not Applicable
Comments:
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES/THURS ROUTING:
Please Route Structural Review Required ❑ No further Review Required
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS:
Approved ❑ Approved with Conditions
DUE DATE: 12-13-11
Not Approved (attach comments) n
Notation:
REVIEWER'S INITIALS: DATE:
Permit Center Use Only..
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents/routing slip.doc
2 -28-02
Contractors or Tradespe1e PO ter Friendly Page
1 •
General /Specialty Contractor
A business registered as a construction contractor with L &I to perform construction work within the scope of
its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Business and Licensing Information
Name PORTLAND MECHANICAL CONTRS UBI No. 602258442
Phone 5036567400 Status Active
Address 2000 Se Hanna Harvester Drive License No. PORTLMCO24KA
Suite /Apt. License Type Construction Contractor
City Milwaukie Effective Date 5/1/1998
State OR Expiration Date 2/27/2012
Zip 97222 Suspend Date
County Out Of State Specialty 1 General
Business Type Corporation Specialty 2 Unused
Parent Company PORTLAND MECHANICAL CONST INC
Other Associated Licenses
License
Name
Type
Specialty
1
Specialty
2
Effective
Date
Expiration
Date
Status
PMCMEML942KC
PMC MECHANICAL
LLC
Construction
Contractor
General
Unused
5/3/2006
5/3/2010
Expired
Business Owner Information
Name
Role
Effective Date
Expiration Date
HETTERVIG, MARK JOHN
President
05/01/1998
Amount
BROOKS, IVAN L.
Secretary
05/01/1998
01/22/2010
VANDEGRIFT, KENNETH
Vice President
05/01/1998
01/22/2010
Bond Information
Page 1 of 1
Bond
Bond Company Name
Bond Account Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Bond Amount
Received Date
3
DEVELOPERS SURETY
& INDEMNITY
550168C
06/12/2002
Until Cancelled
$12,000.00
11/25/2002
Assignment of Savings Information No records found for the previous 6 year period
Insurance Information
Insurance
Company Name
Policy Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Amount
Received Date
11
Liberty
Northwest Ins
Corp
C01174426
10/28/2011
10/28/2012
$1,000,000.0010
/05/2011
10
TRAVELERS
INDEMNITY CO
OF AME
C01085P6861ND09
10/28/2010
10/28/2012
$1,000,000.00
10/05/2011
9
OOHlO CABINS
BK053121776
10/28/2006
10/28/2010
$1,000,000.0010
/30/2009
8
OHIO CASUALTY
INS CO
53121776
10/28/2004
10/28/2006
$1,000,000.00
10/27/2005
Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period
Warrant Information No unsatisfied warrants on file within prior 6 year period
https: // fortress .wa.gov /lni/bbip/Print.aspx
12/22/2011