Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M11-166 - BOEING #14-01
BOEING #14 -01 8701 EAST MARGINAL WY S Mi 1 -166 City oikukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov MECHANICAL PERMIT Parcel No.: 0007400033 Address: 8701 EAST MARGINAL WY S TUKW Project Name: BOEING #14 -01 Permit Number: M1 1-1 66 Issue Date: 12/05/2011 Permit Expires On: 06/02/2012 Owner: Name: BOEING COMPANY THE Address: PROPERTY TAX DEPT , PO BOX 3707 M/C 20 -00 98124 Contact Person: Name: CONNIE HARDIN Address: 4600 S 134 PL , SEATTLE WA 98168 Email: CONNIEH @HOLADAYPARKS.COM Contractor: Name: HOLADAY PARKS, INC. Address: PO BOX 69208 , SEATTLE, WA 98188 Contractor License No: HOLADPI379NO Phone: 206 - 250 -4530 Phone: 206 248 -9700 Expiration Date: 09/03/2013 DESCRIPTION OF WORK: 2 NEW A/C UNITS, DUCT WORK, CONTROLS Value of Mechanical: 550,000.00 Type of Fire Protection: UNKNOWN Electrical Service Provided by: �I Permit Center Authorized Signature: ji Fees Collected: $5,544.56 International Mechanical Code Edition: 2009 Date: 1)---:\c- \c` 6 I I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the perfoxnance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this trmit' Signature: kl _ Print Name: D A L -tu .� Date: ( This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -4/10 M11-166 Printed: 12 -05 -2011 • • PERMIT CONDITIONS Permit No. M11-166 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 7: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 10: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 11: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air- moving equipment upon detection of smoke in the main return -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 12: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) 13: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) 14: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 15: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 16: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 17: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 18: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: IMC -4/10 M11 -166 Printed: 12 -05 -2011 X33 L CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA..2,oy Mechanical Permit No. 01 /1- /6 6 Project No. Date Application Accepted: Waft/ Date Application Expires: 051 (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *please print ** SITE LOCATION Site Address: ing Co Assessor's Tax No.: 00D-1 -( 00033 Suite Number: Floor: New Tenant: ❑ Yes a.No Tenant Name: PROPERTY OWNER Name: ri lnr1.J2 brd rrs Address:l I le0D s 1-4k-k- gQ `c.k Name: ' Phone to �-Sv Lis-738x: d`L11 . %L Email: tvm n e}' 0 ► `O I o'-ct tuk psx,f \CS _Qcs W1 Address: DO &11 ` 3-7 0-7 City: / _ l_rpsz State: tAX__ Zips v tat-1 CONTACT PERSON - person receiving all project communication Name: ri lnr1.J2 brd rrs Address:l I le0D s 1-4k-k- gQ `c.k City- St t� :'Z Zig,•r��1 t l� ic)` Phone to �-Sv Lis-738x: d`L11 . %L Email: tvm n e}' 0 ► `O I o'-ct tuk psx,f \CS _Qcs W1 MECHANICAL CONTRACTOR INFORMATION Company Name: 1' n A23� �S �-) k�s Address: U I -�)Q� 3` l_ City: . n„ Stag -k Zso r —�qc.3 Phone:�c��/1 ()Fax: 206 �`�q E %CL� Contr Reg No Exp Date: el _ is k;(x-V P 1= 37411/4. NO Tukwila Business License No.: gi)S -n (601-57 Valuation of project (contractor's bid price): SS-S-0I OLX) II Describe the scope of work in detail:�� t tb�C t Use: Residential: New ❑ Replacement ❑ Commercial: New Replacement ❑ Fuel Type: Electric ❑ Gas ❑ Other: F1 \Appheanons\Forms- Applications On L,ne1201 1 ApphcattonsNlechantcal Permit Apphcat ion Revised 8- 9- 11does Revised August 2011 bh I'a2e 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended/wall /floor mounted heater Appliance vent Repair or addition to heat/refrig /cooling system Air handling unit <10.000 cfm Unit Type Qty Air handling unit >10.000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm /industrial Unit Type Qty Fire damper Diffuser Thermostat Wood /gas stove Emergency generator Other mechanical equipment Boiler /Compressor Qty 0 -3 hp /100,000 btu 3 -15 hp /500.000 btu 15 -30 hp /1,000.000 btu 30 -50 hp /1,750,000 btu 50+ hp /1.750.000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the perrttit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILD1N t 0 Signature: Print Name: AUT4-IORI D AGENT: 0._.11)r1n r� Date: l lam( -- ( Day Telephone: �((� Mailing Address: ` LODO \ 1 P Lkr)6 &u L cats' City State Zip 11 \Appbcations \Forms- Applicauons On Line2011 Applications`\lechanical Permit Applical ion Revised 8- 9.11.docs Revised August 2011 bh Page 2 of 2 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: / /www.TukwilaWA.gov RECEIPT Parcel No.: 0007400033 Permit Number: M11 -166 Address: 8701 EAST MARGINAL WY S TUKW Status: APPROVED Suite No: Applied Date: 11/18/2011 Applicant: BOEING #14 -01 Issue Date: Receipt No.: R11 -02622 Payment Amount: $4,435.65 Initials: WER Payment Date: 12/05/2011 11:27 AM User ID: 1655 Balance: $0.00 Payee: CONNIE HARDIN TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 01371G ACCOUNT ITEM LIST: Description 4,435.65 Account Code Current Pmts MECHANICAL - NONRES 000.322.102.00.00 4,435.65 Total: $4,435.65 doc: Receiot -06 Printed: 12 -05 -2011 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206- 431 -3665 Web site: http: / /www.TukwilaWA.gov RECEIPT ParcelNo.: 0007400033 Permit Number: M11 -166 Address: 8701 EAST MARGINAL WY S TUKW Status: PENDING Suite No: Applied Date: 11/18/2011 Applicant: BOEING 14 -01 /AIRPLANE COOLING Issue Date: Receipt No.: R11 -02522 Initials: User ID: LAW 1632 Payment Amount: $1,108.91 Payment Date: 11/18/2011 12:46 PM Balance: $4,435.65 Payee: HOLADAY PARKS TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 08351G ACCOUNT ITEM LIST: Description 1,108.91 Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 1,108.91 Total: $1,108.91 doc: Receiot -06 Printed: 11 -18 -2011 • INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. 16( CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 gr- (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project 4r 4 - e' r_ / W/ Type of Inspect' : �e1 Ad ress� Date Called: r Specie Instructions: • • Date Wanted:./ �/ /2... a.m Requester: Phone No: Approved per applicable codes. D Corrections required prior to ap COMMENTS: 1) irt4e-e s 44, /4/..~-A, -1.f.,40f-dd ..r/ riVer/ed 1)7 4f4 pfrefr-bfrefeA( 1-o, 0 k 0 REINSPECTION FEE REQUIRED. Prior o next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. • . • INSPECTION RECORD / °,° etain a copy with permit M � 1 —t� ' • •INSPECTION NO.. PERMIT NO.� •.CITY OF TUKWILA BUILDING DIVISION vvv���►►► 6300 Southcenter Blvd., #100, Tukwila. WA 98188 e- (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: .. at A4. .14 --a( Type o Inspection: /e fj, v6H-. i/� (' Addrre�ssr:i ,� 1,(f , ate Called: Special Instructions: - . Date Want � '.a.m. :. - –1- 1 Z P•m- � Requester: Phone No. �ti—S- 2-i 441 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. C. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Mi( -/ , Pro a A Type of Ins�ppection: Address: 1 e Called: Special Instructions: e� ,4-� -1 u.�.,�'s Date Wanted:. a.m. ` I z —(1 -(/ , Requester: PhoneNo_` _ 4SO_57-13 ElApproved per applicable codes. D Corrections required prior to approval. COMMENTS: A pI?4{ flr�Af V Z._ 7✓1..1 i'J (ii' N ( . O,) c7-746 1-ro A-t 67() l P '7 ".fiz, r in , j D. t 0 "7.46 © —t.4 IJ /,3 u IJ el ,� Ai 2- e�3 !" gft q L--i-vP ,..---1 A a fInspe or: 'Date:' z_15_ (/ ❑ REINSPECTION FEE gQUIRED. Prior to next inspection. fee must be paid at 6300 South yer ter Blvd., Suite 100. Call to schedule reinspection. - INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 Project: - Sprinklers: Type of Inspection Address: P. 7 j r Suite #: 3 -.;' Contact Person: Special Instructions: Occupancy Type Phone No.: Approved per applicable codes. COMMENTS: LICorrections required prior to approval. Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type Inspector: a , , , . Date: 10/ f w Hrs.: r $100.00REINSPECTION FEE REQUIRED. You will receive an invoice from th - ity of Tukwila Finance Department. Call to schedule a reinspection. Attn: 1 Company Name: Address: City: 1 State: 1 Zip: Word /Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 may, "r C, PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M11 -166 DATE: 11 -18 -11 PROJECT NAME: BOEING #14 -01 SITE ADDRESS: 8701 EAST MARGINAL WY S X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: TS: 1\1 j BlJilling Division INJ Public Works ❑ 1U-k-0 ire Prevention WI Planning Division Structural ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 11 -22 -11 Complete k Incomplete n Not Applicable ❑ Comments: Permit Center Use Only . INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route X Structural Review Required n No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 12-20-11 Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only , • CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: • Documents/routing slip.doc 2 -28 -02 Contractors or Tradespeople Pre Friendly Page 0 Page 1 of 2 General /Specialty Contractor A business registered as a construction contractor with LEtI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name HOLADAY PARKS INC UBI No. 578004089 Phone 2062489700 Status Active Address 4600 S 134Th Pl License No. HOLADP1379NO Suite /Apt. License Type Construction Contractor City Seattle Effective Date 1/21/1983 State WA Expiration Date 9/3/2013 Zip 98168 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status HOLADI "00105 HOLADAY PARKS INC Electrical Contractor Hvac /Rfrg Ltd Energy Unused 9/25/2000 4/21/2013 Active HOLADPF376NO HOLADAY PARKS FABRCTRS INC Construction Contractor General Unused 8/20/1963 1/1/1983 Archived Business Owner Information Name Role Effective Date Expiration Date PARKS, GERALD T JR Chief Executive Officer 01/21/1983 VAN DER VEEN, JULIE ELIZABETH Member 08/26/2011 CONNELL, DANIEL AARON Member 08/26/2011 GIRI, BUIT Member 08/26/2011 KIEL, RINALD HOWARD Member 08/26/2011 WHITMYRE, CHRISTIAN Member 08/26/2011 BECK, DAVID CLARENCE Vice President 01/21/1983 OCONNOR, BONNY K Vice President 01/21/1983 NAILON, JUNE ANNETTE Vice President 01/21/1983 VAN DER VEEN, ERIC M Vice President 11/04/2010 PIZZEY, GRACE KATHERINE Vice President 08/26/2011 NELSON, MICHAEL Secretary 01/01/1980 11/04/2010 PARKS, DAVID L Treasurer 01/01/1980 11/04/2010 TALBOT, PAUL Treasurer 01/01/1980 11/04/2010 Bond Information https://fortress.wa.gov/lni/bbip/Print.aspx 12/05/2011 THEBOE/NG COMPANY 14 -01 PHASE 9 HIGH BAY RENOVATION AIRPLANE COOLING FILEC Permit No. P� Plan review approval Is subject to errors and oml> Ions. & : C ;fal of COfStrUCtOn documents does not author 9 t r. ation of any adopted code or ordinance. R c ipt ci p • ' F ' • * and .', is accnowiedged: �__ is 4. 8701 EAST MARGINAL WAY SOUTH TUKWILA, WA 98108 LOCATION IN REGION Date City Of lbkwila BUILDING DrVISION '71:APATE PERMIT _ IU D FOR: [ trl tanicaI ,;Iric:al &i tuning as Fiping My of Tuba ADM DIVISION CODES AND PERMITS PROJECT TITLE: 14 -01 HIGH BAY RENOVATION QUANTITY SUBMITTED: ® 5 SETS: GENERAL PERMIT (SHELL & CORE) OR STRUCTURAL TENANT IMPROVEMENT ❑ 4 SETS TENANT IMPROVEMENT (NON— STRUCTURAL) ❑ 3 SETS: FIRE PROTECTION /SPRINKLERS ❑ 2 SETS: TENANT IMPROVEMENT (REVISION) SUBMITTED FOR PERMIT & REVIEW: JOB NUMBER: 11347785 BUILDING ❑ PLUMBING MECHANICAL ❑ STRUCTURAL GRADING LANDSCAPE DEMOLITION WASHINGTON STATE NON— RESIDENTIAL ENERGY CODE — APPROACHES: COMPLIANCE OPTION ❑ PERSCRIPTIVE ❑ LPA ❑ ANALYSIS 11 N/A SPECIAL INSPECTIONS REQUIRED: (PER IBC CH. 17) ❑ WELD ❑ REBAR ❑ STRUCTURAL BOLTING ❑ OTHER CALCULATIONS TYPE. ATTACHED (YES) (NO) ▪ ELECTRICAL • FIRE PROTECTION ❑ CANTILEVER RACKS C - ❑ CONCRETE ❑ ANCHOR BOLTS ❑ STRUCTURAL OBSERVATION VICINITY PLAN PROJECT DESCRIPTION PROVIDE AIRPLANE COOLING INCLUDING AIR HANDLING EQUIPMENT, DUCTWORK„ CONTROLS, ELECTRICAL POWER, ETC. DUCT ROUTING THRU EXTERIOR WALL AND INTO EXISTING TRENCHES TO AIRPLANE POSITIONS. TWO BREAKROOMS WILL BE MODIFIED TO A ; ;COMMODATE NEW DUCTWORK. LIGHTING, POWER, DATA, MECHANICAL AND FIRE PROTECTION WILL BE MODIFIED AS REQUIRED. EQUIPMENT PAD AND SCREENING IS INCLUDED. REVISIONS No changes shad be made to the scope of work without prior approval of Tukwila Building Division. t: Revisions will require a new plan submittal and may include additional plan review fees. CONTRACTOR LICENSE NUMBER: BOEING * 294ML EXPIRATION DATE: 1 / 20 / 13 BOEING CONTACT: JOHN MURDOCH (253) 740 -0214 CODE AND BUILDING DATA EXISTING PERMITTED DATA - NO CHANGE TO OCCUPANCY OR USE: INTERNATIONAL BUILDING CODE: 2009 EDITION 1. FLOOR AREAS: a) BUILDING STATUS: FIRST FLOOR OFFICE: FIRST FLOOR HIGH BAY: FIRST FLOOR MEZZANINES: SECOND FLOOR OFFICE: THIRD . FLOOR OFFICE: FOURTH FLOOR MEZZANINE: GROSS AREA: b) COVERED LOADING DOCK (14 -16): 2. OCCUPANCY ALLOWED: NO CHANGE a) ACTUAL OCCUPANT LOAD: FIRST SHIFT HIGH BAY: FIRST SHIFT OFFICE TOWER: SECOND SHIFT HIGH BAY AND OFFICE: TOTAL ALL SHIFTS: b) OCCUPANCY GROUP: 3. CONSTRUCTION TYPE: 4. FIRE RESISTIVE REQUIREMENTS: NO CHANGE a EXTERIOR NON— BEARING WALL: b STRUCTURAL FRAME: c PARTITIONS PERMANENT: d SHAFT ENCLOSURES: e FLOORS — CEILING /FLOORS: 0 ROOF — CEILING /ROOF: g) STAIRWAYS: 5. EXITS: NO CHANGE a) CORRIDORS: b) STAID- ENCLOSURES: 6. BUILDING HEIGHT: NO CHANGE a HEIGHT (14 -01): b LOADING DOCK (14-16): 7. BUILDING HEIGHT IN STORIES: NO CHANGE a) FLOORS: 8. SEISMIC ZONE: BUILDING ACCESSIBILITY: 31,280 SF 187,680 SF 500 SF 31,280 SF 31,280 SF 31,280 SF 313,042 SF 5518 SF 300 OCCUPANTS 460 OCCUPANTS 90 OCCUPANTS 850 OCCUPANTS B /F1 OFFICE /MANUF TYPE II —B NON— COMBUSTIBLE NON— COMBUSTIBLE NON— COMBUSTIBLE 1 HOUR NON— COMBUSTIBLE NON — COMBUSTIBLE NON— COMBUSTIBLE 1 HOUR 1 HOUR 59' -0" 3' -10" (PLUS RAILING) 3 STORIES 1 MEZZANINE STORY D AMERICANS WITH DISABILITIES ACT AND WAC CHAPTER 51 Isi 1lj(D(p REVIEWED FOR CODE COMPLIANCE APPROVED NOV 3 0 2011 City of Tukwila BUILDING DIVISION RECEIVED NOV 18 2011 PERMIT CENTER ISSUED FOR CONSTRUCTION - 09.30.11 WIHarris Group Inc. Engineering for Optimum Performance® 12439.00 ® www harrisgroup.com SYM REVISION BY APPROVED DATE SYM REVISION APPROVED DATE 14 -01 PHASE 9 AIRPLANE COOLING — IFC 11347785 HGI SEL 09.30.11 ,�BOE /NG° a� 3966 REGISTERED ARCHITECT STEPHEN E. LUSK STATE OF WASHINGTON ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED DRAWN RVP DATE 08.24.11 APPROVED BY DEPT. DATE CHECKED PWT ENGINEER SEL 08.24.11 08.24.11 SUBTITLE COVER SHEET CURRENT REVISION 11347785 SYMBOL DATE 09.30.11 ROG CHECKED APPROVED 08.24.11 08.24.11 APPROVED TITLE BUILDING 14 -01 ARCHITECTURAL MASTER COL. TUKWILA, WA SHEET GO JOB NO. COMP NO. DWG NO. 14- 001 —GO 6.2 64 7.2 8.2 CAPPED FOR EMERGENCY CONNECTION TO MOBILE COOLING UNIT, SEE I 1M10A M530 8.4 1 M 10A M530 9.2 12" ACY009 3/41'0 CONDENSATE DRAIN REMOTE WALL MOUNTI VOLUME CONTROL FO M300 FOR SEQUENCE PANEL DETAIL D START /STOP AND POSITION 5. SEE OF OPERATION AND EDGE OF WALKWAY FOR FLEX CONNECTION AND DUCT DETAIL, SEE DETAIL 1,2,3 AND 4 ON SHEET M530 —, COORDINATE LOCATION WITH THE EXISTING TRENCH ACCESS HATCH 121'0 ROUTED TO POSITION 5 ACCESS HATCH DAMPER CD -3 AND CD -4, SEE M300 FOR SEQUENCE M1\ MQ 7 -1\ 12"0 ROUTED TO POSITION 4 ACCESS HATCH RECEIVED NOV 18 2011 PERMIT CENTER LEGEND: 1. NOT USED GENERAL NOTES: CONSTRUCTION \OTES: FIELD ROUTE DUCTWORK IN TRENCH TO AVOID OBSTACLES WHILE MINIMIZING OFFSETS. CENTER LINE OF DUCT PENETRATES BUILDING AT 5'± ABOVE FINISHED GRADE. PROVIDE WEATHER —TIGHT FLASHING AT WALL PENETRATION. DROP DUCT DOWN INTO UTILITY TRENCH. PRESSURE SENSOR FOR CONTROL, CONNECT TO BOTH DUCTS WITH 1/4" TUBING WITH SHUTOFF COCKS. ROUTE COND. DRAIN PIPE TO UTILITY TRENCH SUMP. PROVIDE 8x14 ACCESS DOOR. CONTROL DAMPER ACTUATOR SHALL BE INTERCONNECTED TO THE VESDA ALARM PANEL. COORDINATE THE INSTALLATION OF THE CONDUIT AND WIRING TO THE VESDA ALARM PANEL AND FOR THE CONTROL WIRING FROM THE WALL MOUNTED CONTROL TO THE DAMPER ACTUATOR. REVIEWED FOR CODE COMPLIANCE APPROVED NOV 30 2011 City of Tukwila BUILDING DIVISION 8' 4' 0 4' 8' 16' NM MN SCALE: 1/8"=1'-0" ISSUE FOR CO\STRUCTC\-O9.3O.11 FSi consulting engineers • Seattle, Washington Solutions & Service SYM 1 REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE 14 -01 PHASE 9 AIRPLANE COOLING - IFC 11347785 FSi 9.30.11 w4PA C° 0L30.11 AMO ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED DRAWN DATE CHECKED SUBTITLE DUCTWORK PLAN CURRENT REVISION SYMBOL DATE 09.30.11 APPROVED BY DEPT. DATE ENGINEER CHECKED APPROVED APPROVED TITLE MECHANICAL MASTER BUILDING 14-07 COL B- C/6 -9.2 THOMPSON, WA µE� 1M1OA JOB NO. COMP NO. DWG NO. 14- 001 -4M 10A 1M1OB 1M11A 1M11B ../H ____1 7 1M10A,11 L 8' 4' 0 4' 8' 16' NM MN SCALE: 1/8"=1'-0" ISSUE FOR CO\STRUCTC\-O9.3O.11 FSi consulting engineers • Seattle, Washington Solutions & Service SYM 1 REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE 14 -01 PHASE 9 AIRPLANE COOLING - IFC 11347785 FSi 9.30.11 w4PA C° 0L30.11 AMO ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED DRAWN DATE CHECKED SUBTITLE DUCTWORK PLAN CURRENT REVISION SYMBOL DATE 09.30.11 APPROVED BY DEPT. DATE ENGINEER CHECKED APPROVED APPROVED TITLE MECHANICAL MASTER BUILDING 14-07 COL B- C/6 -9.2 THOMPSON, WA µE� 1M1OA JOB NO. COMP NO. DWG NO. 14- 001 -4M 10A FOR CONTINUATION SEE SHEET w J 9.2 10.2 10. .2 11 11.4 12.1 EQUIPMENT MUST BE CONTAINED WITHIN THIS AREA MAINTENANCE CLEARANCES FOR ACY012 12.E z 0 J REMOTE WALL MOUNTED START /STOP AND VOLUME CONTROL FOR POSITION 4. SEE M300 FOR SEQUENCE OF OPERATION AND PANEL DETAIL Li] J 2 0 2E r COORDINATE LOCATION WITH THE EXISTING TRENCH ACCESS HATCH FOR FLEX CONNECTION AND DUCT DETAIL, SEE DETAIL 1,2,3 AND 4 ON SHEET M530 r EDGE OF WALKWAY FOR FLEX CONNECTION AND DUCT DETAIL, SEE DETAIL 1,2,3 AND 4 ON SHEET M530 lir /4.1ivirsi. 123'0 ROUTED TO POSITION 4 ACCESS HATCH POSITIO\ 4 COORDINATE LOCATION WITH THE EXISTING TRENCH ACCESS HATCH i POSITIO\ 3 LEGEND: 1. NOT USED GENERAL NOTES: CONSTRUCTION NOTES: COORDINATE LOCATION WITH THE EXISTING TRENCH ACCESS HATCH MOUNT AT 5' —O" f AFF CONTROL DAMPER ACTUATOR SHALL BE INTERCONNECTED TO THE VESDA ALARM PANEL. COORDINATE THE INSTALLATION OF THE CONDUIT AND WIRING TO THE VESDA ALARM PANEL AND FOR THE CONTROL WIRING FROM THE WALL MOUNTED CONTROL TO THE DAMPER ACTUATOR. REMOTE WALL MOUNTED START /STOP AND VOLUME CONTROL FOR POSITION 3. SEE M300 FOR SEQUENCE OF OPERATION AND PANEL DETAIL 12 "0 ROUTED TO POSITION 3 ACCESS HATCH RECEIVED 1Vg REVIEWED FOR CODE COMPLIANCE APPROVED NOV 3 0 2011 City of Tukwila BUILDING DIVISION 124 T I� J 1M10A /1M10B/ 1M11A 1M116 Nov 182011 KEY PLA PERMIT CENTER SCALE: NONE 8' 4' 0 4' 8' 16' M! 1 SCALE: 1 /8 " =1' -0" 0 ISSUE FOR CO \STRUCTIO \- 09.3C.11 iii• FSi consulting engineers Seattle, Washington Solutions &C Service SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE 14 -01 PHASE 9 AIRPLANE COOLING - IFC 11347785 FSi 09.30.11 pirOE /NQ' 0920.11 SIGIND ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED DRAWN CHECKED DATE SUBTITLE DUCTWORK PLAN CURRENT REVISION SYMBOL DATE 09.30.11 APPROVED BY DEPT. DATE ENGINEER CHECKED APPROVED APPROVED TITLE BUILDING 14 -01 MECHANICAL MASTER COL B —C/9.2 -12.4 THOMPSON, WA SHEET IM1OB JOB NO. COMP NO. DWG NO. 14-001 -4M 1 OB EQUIPMENT MUST BE CONTAINED WITHIN THIS AREA 12.E MAINTENANCE CLEARANCES 12"0 FOR ACY012 3/4"0 CONDENSATE DRAIN CO FOR CONTINUATION SEE w 1- i ACY012 A 13 1M11A M530 132 CAPPED FOR EMERGENCY CONNECTION TO MOBILE COOLING UNIT, SEE 13.4 14 172 14.4 15.2 15.4 1M11A M53 <EEP CLEAR 1110TE!T01 ma mom 2" REMOTE WALL MOUNTE TART /STOP AND VOLUME CONTROL FOR'1 P SITION 2. SEE M300 FOR SEQUENCE bF OPERATION AN PANEL DETAIL-- ,) >>=1 J r u- • A 0 L DAMPER CD -1 AND CD -2, SEE M300 FOR SEQUENCE 1 12 "0 ROUTED TO POSITION 3 ACCESS HATCH COORDINATE LOCATION WITH THE EXISTING TRENCH ACCESS HATCH EDGE OF WALKWAY FOR FLEX CONNECTION AND DUCT DETAIL, SEE DETAIL 1,2,3 AND 4 ON SHEET M530 12 "0 ROUTED TO POSITION 2 ACCESS HATCH • kikkk REVIEWED FOR COD CQMPLUAWC APPROVED NOV 3 0 2011 City of Tukwila BUILDING DIVISION RECEIVED NOV 18 2011 PERMIT CENTER LEGEND: 1.NOT USED GE \ERAL NOTES: CONSTRUCTION NOTES: FIELD ROUTE DUCTWORK IN TRENCH TO AVOID OBSTACLES WHILE MINIMIZING OFFSETS CENTER LINE OF DUCT PENETRATES BUILDING THROUGH 25 "x49" WALL OPENING AT 5'± ABOVE FINISHED GRADE. PROVIDE WEATHER —TIGHT FLASHING AT WALL PENETRATION. DROP DUCT DOWN INTO UTILITY TRENCH PRESSURE SENSOR FOR CONTROL, CONNECT TO BOTH DUCTS WITH 1/4" TUBING WITH SHUTOFF COCKS ROUTE COND. DRAIN PIPE TO UTILITY TRENCH SUMP. 6> PROVIDE 8x14 ACCESS DOOR. CONTROL DAMPER ACTUATOR SHALL BE INTERCONNECTED TO THE VESDA ALARM PANEL. COORDINATE THE INSTALLATION OF THE CONDUIT AND WIRING TO THE VESDA ALARM PANEL AND FOR THE CONTROL WIRING FROM THE WALL MOUNTED CONTROL TO THE DAMPER ACTUATOR. 112.4 T n ___1 1M10A 1M1OB %1M11A /, 1M11B KEY PLAN SCALE: NONE 8' 4' 0 4' 8' 16' IN , ■■ ■ ■ ■_ SCALE: 1/8"=1'-0" 0 ISSUE FOR CO \STRUCTIC \-09.30.11 FSi consulting engineers • Seattle, Washington Solutions 8c Service SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE 1 14 -01 PHASE 9 AIRPLANE COOLING - IFC 11347785 FSi 09.30.11 M30.11 am ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED DRAWN DATE CHECKED SUBTITLE DUCTWORK PLAN CURRENT REVISION SYMBOL DATE 09.30.11 APPROVED BY DEPT. DATE ENGINEER CHECKED APPROVED APPROVED TITLE MECHANICAL MASTER BUILDING 14 -01 COL B— C/12.4 -16 THOMPSON, WA SHEET 1M11A JOB NO. COMP NO. DWG NO. 14- 001 -4M11A AC UNIT SCHEDULE MARK LOCATION SERVICE ECON MIN OSA (CFM) SUPPLY FAN CONDENSER FANS DX COOLING ELECTRIC HEAT FILTERS MAX SOUND LEVELS BASIS OF DESIGN NOTES TYPE VOL CFM ESP (IN) [3] TSP (IN) [5] FAN RPM [1] MOTOR TYPE VOL QUANTITY CFM ESP (IN) [3] TSP (IN) [5] FAN RPM MOTOR NOM CLG TONS [7] EAT DB/WB (DEG F) LAT DB/WB (DEG F) FLUID MINIMUM [KW] TYPE MAX VEL (FPM) SPEED NOM HP BHP [6] VOL NOM HP BHP [6] ACY009 & ACY012 AT GRADE, COLUMN LINE 9 &12 P8 AIRCRAFT N 7,000 BLOWER VAR 7,000 24 38 3358 VFD 50 40.0 PROP VAR 3 15,000 1.30 2.8 - VFD 10 - 30 91/67 40/XX 134A 90 MANUFACTURER STANDARD - [8] FMC TECHNOLOGIES JETWAY 75 PCA UNIT * [9],[10],[11] SCHEDULE NOTES: [1 ] WITH UNIT AT MAXIMUM CONDITIONS [2 ] NOT USED [3 ] STATIC PRESSURE EXTERNAL TO UNIT [4 ] NOT USED [5] TOTAL STATIC PRESSURE ACROSS FAN [6] MAXIMUM ALLOWABLE MOTOR BRAKEHORSEPOWER AT MAX FLOW AND TSP [7] NOMINAL TONNAGE INCLUDED FOR REFERENCE ONLY - DO NOT USE FOR FINAL SIZING OF EQUIPMENT [8] RADIATED NOISE SHALL BE IN COMPLIANCE WITH LOCAL NOISE ORDINANCES [9] THREE INDEPENDENT REFRIGERATION SYSTEMS, AT LEAST TWO WITH HOT GAS BYPASS FOR REFRIGERATION CONTROL [10] THE SUPPLY FAN'S VFD SHALL BE CONTROLLED BY PRESSURE SENSOR, SEE SEQUENCE AND PLAN SHEETS [11] UNIT TO COME WITH MANUFACTURERS STANDARD STAND * Or Approved Equal Manufacturer CO \TROL DAvPER SCHE2ULE MARK SERVICE TYPE DESIGN C.F.M. DESIGN VEL FPM (MAX) PRESS DROP (IN. W.G.) SIZE H x W REMARKS CD -1 POSITION 2 OPPOSED BLADE 3,500 4500 .25 12 X 12 GREENHECK HCD -430* CD -2 POSITION 3 OPPOSED BLADE 3,500 4500 .25 12 X 12 GREENHECK HCD -430* CD -3 POSITION 4 OPPOSED BLADE 3,500 4500 .25 12 X 12 GREENHECK HCD -430* CD -4 POSITION 5 OPPOSED BLADE 3,500 4500 .25 12 X 12 GREENHECK HCD -430* *OR OTHER APPROVED MANUFACTURER SEQUENCE OF OPERATION THE WALL — MOUNTED CONTROL PANEL SHALL CONTAIN AN ON /OFF SWITCH. AND A TEMPERATURE CONTROL KNOB. EACH AC UNIT IS OPERATED BY A WALL — MOUNTED CONTROL PANEL. THE AC UNIT'S INTERNAL CONTROL SYSTEM WILL SEQUENCE THE AC UNIT COOLING AND HEATING TO MAINTAIN THE DISCHARGE TEMPERATURE SETPOINT, WHICH WILL BE ESTABLISHED DURING TAB AND COMMISSIONING. WHEN THE ON /OFF SWITCH, LINKED TO A SPECIFIC AC UNIT, IS MOVED TO THE ON POSITION, THE ASSOCIATED SUPPLY AIR FAN SHALL START AND THE AC UNIT'S INTERNAL CONTROL SYSTEM SHALL MAINTAIN THE DISCHARGE TEMPERATURE SETPOINT. THE AC UNIT HAS A VFD DRIVE WHICH SHALL BE CONTROLLED TO MAINTAIN A PRESSURE SETPOINT AT THE DAMPER (CD —X) INLET. THE FAN SPEED SHALL BE CONTROLLED BY THE VFD BY A SIGNAL FROM THE REMOTE DUCT — MOUNTED SENSOR. THE SETPOINT SHALL BE ESTABLISHED DURING THE TAB /COMMISSIONING PHASE AND SHALL BE FIELD PROGRAMMED INTO THE SUPPLY FAN VFD. WHEN THE ON /OFF SWITCH (ON THE WALL — MOUNTED CONTROL PANELS) IS MOVED TO THE OFF POSITION, THE AC UNIT SHALL POWER OFF. THE TEMPERATURE CONTROL KNOB SHALL CONTROL THE VOLUME DAMPER POSITION (CD -1 THROUGH CD -4) FROM FULL OPEN TO A MINIMUM SETTING. THE CONTROL DAMPER ASSOCIATED WITH THE WALL — MOUNTED CONTROL PANEL SHALL MODULATE TO THE POSITION COMMANDED BY THE SETTING OF THE CONTROL KNOB WHEN THE ON /OFF SWITCH IS MOVED TO THE ON POSITION. THE DAMPER SHALL CLOSE WHEN THE ON /OFF SWITCH IS MOVED TO THE OFF POSITION. UPON A SIGNAL FROM THE ASSOCIATED AIRPLANE'S VESDA POWER SHUTDOWN INTERFACE RELAY PANEL, THE DAMPER SHALL CLOSE. (MAKE THE NECESSARY PROVISIONS TO ENSURE THAT THE TWO DEVICES ARE COMPATIBLE) ON OFF COOLER WALL- V OU \TE DETA_ J CC \TROL PA\ SCALE: 4 " =1' -0" 1M1013_ M -300 EL REVIEWED FOR CODE COMPLIANCE APPROVED NOV 3 0 2011 City of Tukwila BUILDING DIVISION RECEIVED NOV 18 2011 PERMIT CENTER ISSUE FCR co\sTRUCrio \- C9.30.11 • FSi consulting engineers Seattle, Washington Solutions & Service REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE 14 -01 PHASE 9 AIRPLANE COOLING - IFC 11347785 FSi 09.30.11 QBOE /NG' a•- o.o.,, MWM ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED DRAWN DATE CHECKED SUBTITLE SCHEDULE CURRENT REVISION SYMBOL DATE 09.30.11 APPROVED BY DEPT. DATE ENGINEER CHECKED APPROVED APPROVED TITLE MECHANICAL MASTER BUILDING 14 -07 SHEET M300 JOB NO. COMP NO. THOMPSON, WA DWG NO. 14- 001 -4M11 B 3/4" WIDE x 1/8" THICK CLOSED CELL NEOPRENE GASKET (ON BOTTOM OF ELBOW FLANGE) ELBOW FLANGE 8" o DUCT 1/2" WIDE x 2" LONG NYLON TAPERED GUIDE MOUNTED TO TOP OF FLANGE DETAIL SCALE: 4 " =1' -0" 1 1M1OB M -530 EXISTING 12" x 30" TRENCH ACCESS HATCH 8"0 x 2 "x $" FLANGE ATTACH SUPPORT BRACES TO WALLS OR FLOOR OF TRENCH, FIELD ROUTE BRACING M530 ii 1/2" BOLT WITH WASHER WELDED TO BOLT HEAD 1/2" WIDE NYLON TAPERED GUIDE 1 L l� i� k DETAIL SCALE: 12 " =1' -0" ,-r - -- -HANGAR FLOOR TRENCH COVER 2 M530 120 DUCT UP FROM TRENCH z— UTILITY TRENCH FLOOR APPROX. 4' +/– ELBOW FLANGE CLOSED CELL NEOPRENE GASKET DUCT FLANGE 2 1M1OB M -530 DETAIL (4S4 CALE 3"=1'-0" 1 M 10131M-530 4" LONG, 3/8"0 ROD HANDLE, ONE EACH SIDE, WELD TO DUCT 8"0 DUCT ELBOW FLANGE 16 GA PLATE DETAIL SCALE: 4 " =1' -0" 3 1 M 106E -530 COVER PLATE WITH HANDLE, FROM 3/8" ROD 1/8" THICK CLOSED CELL NEOPRENE GASKET DETAIL %`J SCALE: 3 " =1' —O" 1 M 10A 1 M -530 1M11A 12 "0 SECTION A SCALE: 1/2"=1'=0" 1 M 1 OA LM -530 1M11A 12"0 x 2" x 1/8" FLANGE 3/8" BOLTS, 4" ON CENTER COOLING UNIT 5� M530 12"0 DUCT MOUNT OWNER SUPPLIED, FLEXIBLE DUCT CONNECTOR HARDWARE TO THE END OF THE 12"0 ELBOW FABRICATE ELBOW USING 16 GA SHEET METAL rt 121'0 x 2 "x g" FLANGE J % / / / / / / LEGEND: 1.NOT USED GENERAL NOTES: 1.NOT USED CONSTRUCTION NOTES: ADJUST THE HEIGHT OF THE BOLT HEAD /WASHER TO PROVIDE POSITIVE SEALING BY THE NEOPRENE GASKET. WHEN THE SEAL IS ACCEPTABLE, WELD THE BOLT, WASHER, AND NUT TO THE DUCT FLANGE. IM—Kp(e / ELBOW FLANGE f 1/2" WIDE x 2" LONG NYLON TAPERED GUIDE (3/32" THICK AT THE HIGH END) 3/4" WIDE x 1/8" THICK CLOSED CELL NEOPRENE GASKET SECTION SCALE: NTS B M -530 M -530 120 DUCT ANGLE IRON SUPPORTS SECTION SCALE: 3 " =1' -0" (c1 M -530 M -530 "KEYHOLE" SLOT FOR BOLT HEAD AND WASHER REVIEWED FOR CODE COMPLIANCE APPROVED NOV 3 0 2011 City of Tukwila BUILDING DMMMS O �1» RECEIVED NOV 18 2011 PERMITCENTER SCALE: 1 /8 " =1' -0" ISSUE FOR CO \STRUCTIO \- 09.30.11 FSi consulting engineers • Seattle, Washington Solutions & Service SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE 14 -01 PHASE 9 AIRPLANE COOLING — IFC 11347785 FSi 09.30.11 Q�BOE /NG' ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED DRAWN DATE CHECKED SUBTITLE DETAILS CURRENT REVISION SYMBOL DATE 09.30.11 APPROVED BY DEPT. DATE ENGINEER CHECKED APPROVED APPROVED TITLE MECHANICAL MASTER BUILDING 14-01 COL B–C/16-19 SHEET M530 JOB NO. COMP NO. THOMPSON, WA DWG No. 14- 001 -4M11 B