Loading...
HomeMy WebLinkAboutPermit M11-170 - SAVVIS - SE 2 OFFICE EXPANSIONSAVVIS SE2 OFFICE EXPANSION 12301 TUKWILA INTERNATIONAL BL Mi 1 -170 Parcel No.: Address: City oftukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov MECHANICAL PERMIT 0923049367 12301 TUKWILA INTERNATIONAL BL TUKW Project Name: SAVVIS SE 2 OFFICE EXPANSION Permit Number: Issue Date: Permit Expires On: M11 -170 12/12/2011 06/09/2012 Owner: Name: Address: Contact Person: Name: Address: Email: INTERNATIONAL GATEWAY WEST 12201 TUKWILA INTERNATIONAL BLVD , SEATTLE WA 98168 DARLA DOLL 7717 DETROIT AV SW , SEATTLE WA 98106 DARLA. D O LL @MACMILLER. C O M Contractor: Name: MACDONALD /MILLER FAC SOL INC Address: PO BOX 47983 , SEATTLE, WA 98106 Contractor License No: MACDOFS980RU Phone: 206 768 -4278 Phone: 206 - 768 -4180 Expiration Date: 12/31/2012 DESCRIPTION OF WORK: ADD (3) VAV BOXES AND (6) DIFFUSER/GRILLES Value of Mechanical: $8,000.00 Type of Fire Protection: SPRINKLERS /AFA Electrical Service Provided by: Permit Center Authorized Signature: I hereby certify that I have read and governing this work will be complie x. with, The granting of this permit does not pr construction or the performance of work. back of this permit. Fees Collected: $281.56 International Mechanical Code Edition: 2009 Date: 1f2._ (l 11 ed this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. Lie to give authority to violate or cancel the provisions of any other state or local laws regulating I am authorized to sign and obtain this mechanical permit and agree to the conditions on the Signature: Print Name: Date: /11/2--/// %2(// This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -4/10 M11 -170 Printed: 12 -12 -2011 PERMIT CONDITIONS Permit No. M1 1-170 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IMC -4/10 M11-170 Printed: 12 -12 -2011 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto://www.ci.tukwila.wa.us Mechanical Permit No. N1 t� no Project No. (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *please print ** SITE LOCATION King Co Assessor's Tax No.: 0923049367 Site Address: 12301 TUKWILA INT'L BLVD TUKWILA, WA 98168 Tenant Name: SAWIS SE2 OFFICE EXPANSION Property Owners Name: SAWIS Mailing Address: 12301 TUKWILA INT'L BLVD Suite Number: SE 2 Floor: FL 1 New Tenant: ❑ Yes m ..No TUKWILA City WA 98168 State Zip CONTACT PERSON who do we contact when your permit is ready to be issued' Name: DARLA DOLL Mailing Address: 7717 DETROIT AVE SW Day Telephone: (206) 768 -4278 SEATTLE WA 98106 E -Mail Address: DARLA.DOLL @MACMILLER.COM City State Fax Number: (206) 768 -4279 Zip MECHANICAL CONTRACTOR INFORMATION Company Name: MACDONALD MILLER Mailing Address: 7717 DETROIT AVE SW SEATTLE WA 98106 Contact Person: DARLA DOLL E -Mail Address: DARLA.DOLL @MACMILLER.COM Contractor Registration Number: MACDOFS980RU City State Day Telephone: (206) 768 -4278 Fax Number: (206) 768 -4279 Expiration Date: 12/31/2012 Zip ARCHITECT OF RECORD — All plans must be stamped by architect of record Company Name: N/A Mailing Address: City Day Telephone: Fax Number: Contact Person: E -Mail Address: State Zip ENGINEER OF RECORD — All plans must be stamped by engineer of record Company Name: MACDONALD MILLER Mailing Address: 7717 DETROIT AVE SW Contact Person: JASON LIENING SEATTLE WA 98106 E -Mail Address: JASON.LIENING @MACMILLER.COM H:\Applications\Ponns- Applications On Line\2010 Applications \7 -2010 - Mechanical Permit Application.doc Revised. 7 -2010 bh City State Day Telephone: (206) 768 -3892 Fax Number: (206) 768 -3893 Zip Page 1 of 2 Valuation of project (contractor's bid price): $ 8000.00 Scope of work (please provide detailed information): ADD (3) VAV BOXES, ADD (6) DIFFUSER/GRILLES AND MISC DUCTWORK Use: Residential: New ❑ Replacement ❑ Commercial: New m Replacement ❑ Fuel Type: Electric m Gas Other: Indicate type of mechanical work being installed and the quant'ty below: Unit Type: Qty Unit Type: Qty Unit Type: Qty Bioler /Compressor Qty furnace <100k btu air handling unit >10,000 cfm fire damper 0 -3 hp /100,000 btu furnace >100k btu evaporator cooler diffuser 6 3 -15 hp /500,000 btu floor furnace ventilation fan connected to single duct thermostat 15 -30 hp /1,000,000 btu suspended/wall /floor mounted heater ventilation system wood/gas stove 30 -50 hp /1,750,000 btu appliance vent hood and duct emergency generator 50+ hp /1,750,000 btu repair or addition to heat/refrig/cooling system Incinerator — domestic other mechanical equipment air handling unit <10,000 cfm 3 incinerator — comm /ind PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 international building code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING QWNER UTHORIZED A T: Signature: Date: 12/01/2011 Print Name: DARLA DOLL Day Telephone: (206) 768 -4278 Mailing Address: 7717 DETROIT AVE SW SEATTLE WA 98106 IDate Application Accepted: City Date Application Expires: j (a 2_ H:\ApplicationsTorms- Applications On Line\2010 Applications \7.2010- Mechanical Permit Application.doc Revised: 7 -2010 bh State Zip Staff Initials: �/ 1 Page 2 of 2 • City of Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov RECEIPT Parcel No.: 0923049367 Permit Number: M11 -170 Address: 12301 TUKWILA INTERNATIONAL BL TUKW Status: PENDING Suite No: Applied Date: 12/02/2011 Applicant: SAWIS SE 2 OFFICE EXPANSION Issue Date: Receipt No.: R11 -02610 Initials: User ID: Payee: JEM 1165 Payment Amount: $281.56 Payment Date: 12/02/2011 11:01 AM Balance: $0.00 MACDONALD- MILLER FACILITY SOLUTIONS, INC. TRANSACTION LIST: Type Method Descriptio Amount Payment Check 3161 281.56 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts MECHANICAL - NONRES PLAN CHECK - NONRES 000.322.102.00.00 225.25 000.345.830 56.31 Total: $281.56 doc: Receiot -06 Printed: 12 -02 -2011 INSPECTION NO. INSPECTION RECORD Retain a copy with permit //- /70 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION \,( 6300 Southcenter Blvd., #100, Tukwila: WA 98188 (206) 431 =3670 Permit Inspection Request Line (206) 431 -2451 Project: y,/ C Typee of Inspection: /00 r /Ndt/ ,�( // • O Addr ss: /230 / r.rrr Date Called: Special Instructions: _ ,7G6 —i4y/ 6 5- 7'a/ --C/ -3k 3 - Date Wanted:. / -70-'2 ?:�.- R uester: Phone No: 20b — 7.6 r_ 4/27r MApproved per applicable codes. COMMENTS: Corrections required prior to approval. ‹P rol,'' % A.77iu,� 0 h (Date: / d4-1 L nQUI REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 7. �Z INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 p.., (206) 431 -3670 . Permit Inspection Request Line (206) 431 -2451 Mt f r7 0 Project,: V v 1 S Type o Inspection: of —1—id AR Q A. Address: I1030i —e Date Called: Special Instructions: • ,,- . tJ ,JS Date . Z , t j !;mom p.m. Requester: Phonie No� ✓ 1 9 t�V s 1 — O+ if Q t Approved per applicable codes. ['Corrections required prior to approval. I COMMENTS: . tJ ,JS ,50 .0Jc_ --e -og- e_•,----./ L... I .4 '.e- /Di 72,n1. • c J J, -a/ff /3V i r f 1 Inspec ar: ❑REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. flu-ik A 1Date:, 2 :. INSPECTION RECORD • Retain a copy with permit • .. INSPECTION Na • • PERMIT NO.� at( CITY OF TUKWILA BUILDING DIVISION • t O0 Southcenter Blvd.., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspeetion Request Line (206) 431 -2451 Mkt- la Project - ` .. C _ AVU!LS - Type of Inspection: Q a ue, If Me • Addrre�7ss: r ',t^ Date Called: Specialan'stiuction "s: . Date Wanted:. t�. -r`(' •••.a.1.. �+ p.m. Requester: Phone No: 7)0(4,..:---31(-- i 0 t, .D'Approved per applicable codes. Corrections required prior to approval. COMMENTS: _.L.: ` . . r ' r A j P 1bor re- 'r.i , e ; Date :' S- , 0 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. FILE COPY PROJECT INFORMATION Location Building owner Program user Company Comments By Dataset name Calculation time TRACE® 700 version Location Latitude Longitude Time Zone Elevation Barometric pressure Air density Air specific heat Density- specific heat product Latent heat factor Enthalpy factor Summer design dry bulb Summer design wet bulb Winter design dry bulb Summer clearness number Winter dearness number Summer ground reflectance Winter ground reflectance Carbon Dioxide Level Design simulation period Cooling Toad methodology Heating Toad methodology MACDONALD - MACMILLER C:1CDS1ProjectslSavvis17316986 Savvis.TRC 06:37 AM on 11/09/2011 6.2.6.5 Seattle 47.5 122.3 8 0 30.0 0.0763 0.2444 1.1185 4,923.6 4.5759 83 65 24 0.92 0.87 0.20 0.20 400 deg deg ft in. Hg lb/cu ft Btu/lb-°F Btu /h•cfm• °F Btu•min /h•cu ft Ib•min /hr-cu ft °F °F °F ppm January - December CLTD -CLF (ASHRAE TFMI UATD REVIEWED FOR CODE COMPLIANCE APPROVED DEC 0 9 2011 City of Tukwila BUILDING DIVISION I RACEmo What,* tram Tram KAIH1O Room Checksums By MACDONALD - MACMILLER 110 - Office COOLING COIL PEAK Peaked at Time: Mo /Hr. 7 / 10 Outside Air: OADB/WB/H R: 72 / 63 / 70 Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass/Door Cond Wall Cond Partition/Door Floor Adjacent Floor Infiltration Sub Total = => Internal Loads Lights People Misc Sub Total = => Ceiling Load Ventilation Load Adj Air Trans Heat Dehumid. Ov Sizing Ov /Undr Sizing Exhaust Heat Sup. Fan Heat Ret Fan Heat Duct Heat Pkup Underflr Sup Ht Pkup Supply Air Leakage Grand Total => Space Plenum Sens. + Lat Sens. + Lat Btu /h Btu/h CLG SPACE PEAK Mo/Hr 7 / 10 OADB: 72 Net Percent Space Total Of Total Sensible Btu/h ( %) Btu/h O o 0 0 0 O 0 0 0 0 O 0 0 0 0 6,333 0 6,333 71 6,333 -214 0 -214 -2 -214 549 406 955 11 549 O 0 0 0 0 0 0 0 O 0 0 0 0 O 0 0 0 6,667 406 7,073 79 6,667 583 146 729 8 583 450 0 450 5 250 650 0 650 7 650 1,683 146 1,829 20 1,483 45 -45 0 0 45 O 0 59 1 0 O 0 0 0 O 0 O 0 0 0 -14 -14 0 O 0 O 0 0 O 0 0 O 0 O 0 0 Percent Of Total ( %) 0 0 0 77 -3 7 0 0 0 0 81 7 3 8 18 0 0 0 8,395 493 8,947 100.00 8,195 100.00 Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass/Door Cond Wall Cond Partition/Door Floor Adjacent Floor Infiltration Sub Total = => Internal Loads Lights People Misc Sub Total =_> Ceiling Load Ventilation Load Adj Air Trans Heat OvlUndr Sizing Exhaust Heat OA Preheat Diff. RA Preheat Diff. Additional Reheat System Plenum Heat Underflr Sup Ht Pkup Supply Air Leakage Grand Total => HEATING COIL PEAK Mo/Hr. Heating Design OADB: 24 Space Peak Space Sens Btu/h 0 0 0 0 -2,123 -506 0 0 0 -763 -3,392 0 250 0 250 -24 0 0 0 -3,166 Coil Peak Tot Sens Btu/h Percent Of Total ( %) O 0.00 O 0.00 O 0.00 O 0.00 -2,123 37.42 -882 15.55 O 0.00 O 0.00 O 0.00 -763 13.45 -3,768 66.43 O 0.00 250 -4.41 O 0.00 250 -4.41 O 0.00 -807 14.22 O 0 O 0.00 14 -0.25 O 0.00 -1,537 27.09 O 0.00 175 -3.08 O 0.00 O 0.00 -5,673 100.00 Main Clg Aux Clg Opt Vent Total Total Capacity ton MBh 0.8 9.0 0.0 0.0 0.0 0.0 0.8 9.0 COOLING COIL SELECTION Sens Cap. Coil Airflow Enter DB/WB/HR MBh cfm °F °F grtlb 8.6 366 75.6 61.7 59.9 0.0 0 0.0 0.0 0.0 0.0 0 0.0 0.0 0.0 Leave DB/WB/HR °F °F gr/lb 55.0 53.3 57.9 0.0 0.0 0.0 0.0 0.0 0.0 Project Name: Dataset Name: 7316986 Savvis.TRC AREAS Gross Total Glass f0 ( %) Floor 178 Part 0 Int Door 0 ExFIr 0 Roof 0 Wall 228 90 40 Ext Door 0 O 0 O 0 TEMPERATURES Cooling Heating 55.0 77.7 75.8 69.6 75.8 69.6 75.6 63.1 0.0 0.0 0.0 0.0 0.0 0.0 SADB Ra Plenum Return Ret/OA Fn MtrTD Fn BIdTD Fn Frict AIRFLOWS Cooling 366 366 366 366 16 16 0 110 366 16 0 0 0 0 Diffuser Terminal Main Fan Sec Fan Nom Vent AHU Vent Infil MinStopIRh Retum Exhaust Rm Exh Auxiliary Leakage Dwn Leakage Ups Heating 366 366 110 366 16 16 15 110 125 31 0 0 0 0 ENGINEERING CKS % OA cfm/ft' cfm/ton ft/ton Btu/Fir-ft' No. People Cooling 4.3 2.06 491.37 238.74 50.26 1 Heating 4.3 2.06 -31.87 HEATING COIL SELECTION Capacity Coil Airflow Ent Lvg MBh cfm °F °F Main Htg Aux Htg Preheat Humidif Opt Vent Total -5.1 366 65.2 77.7 0.0 0 0.0 0.0 -0.5 16 24.0 55.0 0.0 0 0.0 0.0 0.0 0 0.0 0.0 -5.7 TRACE® 700 v6.2.6.5 calculated at 06:37 AM on 11/09/2011 Altemative - 1 System Checksums Report Page 1 of 3 Room Checksums By MACDONALD - MACMILLER 111 - Office COOLING COIL PEAK Peaked at Time: Outside Air: Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass/Door Cond Wall Cond Partition/Door Floor Adjacent Floor Infiltration Sub Total =_> Internal Loads Lights People Misc Sub Total = => Ceiling Load Ventilation Load Adj Air Trans Heat Dehumid. Ov Sizing Ov /Undr Sizing Exhaust Heat Sup. Fan Heat Ret Fan Heat Duct Heat Pkup Under& Sup Ht Pkup Supply Air Leakage Grand Total => Mo /Hr. 7 / 15 OADBMIB /HR: 83 / 66 / 67 Space Plenum Sens. + Lat Sens. + Lat Btu/h Btu/h 0 0 0 0 0 0 0 0 0 0 0 Net Percent Total Of Total Btu/h (%) O 0 0 O 0 0 O 0 0 O 0 0 O 0 0 O 0 0 o 0 o o O o 0 o o O o 0 557 139 696 35 450 0 450 23 650 0 650 33 1,657 139 1,796 90 35 -35 0 0 O 0 214 11 O 0 0 O 0 O 0 0 -11 -11 -1 0 0 O 0 0 O 0 0 O 0 0 0 0 1,692 93 1,999 100.00 CLG SPACE PEAK Mo/Hr. 8 / 9 OADB: 71 Space Sensible Btu/h Percent Of Total ( %) O 0 O 0 O 0 O 0 O 0 O 0 O 0 O 0 O 0 O 0 O 0 557 250 650 1,457 44 0 0 0 1,501 37 17 43 97 3 0 0 0 100.00 Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass/Door Cond Wall Cond Partition/Door Floor Adjacent Floor Infiltration Sub Total = => Internal Loads Lights People Misc Sub Total = => Ceiling Load Ventilation Load Adj Air Trans Heat OvlUndr Sizing Exhaust Heat OA Preheat Diff. RA Preheat Diff. Additional Reheat System Plenum Heat Underflr Sup Ht Pkup Supply Air Leakage Grand Total => HEATING COIL PEAK Mo/Hr. Heating Design OADB: 24 Space Peak Coil Peak Percent Space Sens Tot Sens Of Total Btu/h Btu/h ( %) O 0 0.00 O 0 0.00 O 0 0.00 O 0 0.00 O 0 0.00 O 0 0.00 O 0 0.00 O 0 0.00 O 0 0.00 -729 -729 52.51 -729 -729 52.51 O 0 0.00 250 250 -18.01 O 0 0.00 250 250 -18.01 -23 0 0.00 O -782 56.34 O 0 0 O 0 0.00 14 -0.99 0 0.00 -80 5.79 O 0.00 -60 4.36 O 0.00 O 0.00 -501 -1,388 100.00 Main Clg Aux CIg Opt Vent Total Total Capacity ton MBh 0.2 2.0 0.0 0.0 0.0 0.0 0.2 2.0 COOLING COIL SELECTION Sens Cap. Coil Airflow Enter DBIWBIHR MBh cfm °F °F gr/Ib 1.7 67 77.3 62.6 61.1 0.0 0 0.0 0.0 0.0 0.0 0 0.0 0.0 0.0 Leave DBIWB/HR °F °F gr/Ib 55.0 52.3 54.0 0.0 0.0 0.0 0.0 0.0 0.0 Project Name: Dataset Name: 7316986 Savvis.TRC AREAS Gross Total Glass Floor 170 Part 0 Int Door 0 ExFIr 0 Roof 0 Wall 0 Ext Door 0 ft2 ( %) O 0 O 0 0 0 TEMPERATURES Cooling Heating 55.0 76.7 75.7 69.6 75.7 69.6 77.3 35.2 0.0 0.0 0.0 0.0 0.0 0.0 SADB Ra Plenum Return Ret/OA Fn MtrTD Fn BIdTD Fn Frict AIRFLOWS Cooling 67 67 67 67 15 15 0 20 67 15 0 0 0 0 Diffuser Terminal Main Fan Sec Fan Nom Vent AHU Vent Infil MinStoplRh Return Exhaust Rm Exh Auxiliary Leakage Dwn Leakage Ups Heating 67 67 20 67 15 15 14 20 34 29 0 0 0 0 ENGINEERING CKS % OA cfm/fe cfm/ton ft/ton Btu/hrfe No. People Cooling 22.7 0.39 402.76 1,020.47 11.76 1 Heating 22.7 0.39 -8.17 HEATING COIL SELECTION Capacity Coil Airflow Ent MBh cfm °F Main Htg Aux Htg Preheat Humidif Opt Vent Total -0.9 67 65.2 0.0 0 0.0 -0.5 15 24.0 0.0 0.0 -1.4 Lvg °F 76.7 0.0 55.0 0 0.0 0.0 0 0.0 0.0 TRACE® 700 v6.2.6.5 calculated at 06:37 AM on 11/09/2011 Alternative - 1 System Checksums Report Page 2 of 3 Room Checksums By MACDONALD - MACMILLER 112 - Conference COOLING COIL PEAK Peaked at Time: Mo /Hr. 7 / 15 CLG SPACE PEAK Mo/Hr. 8 / 9 HEATING COIL PEAK Mohr. Heating Design TEMPERATURES Cooling Heating Outside Air: OADB/WB/HR: 83 / 66 / 67 OADB: 71 OADB: 24 SADB 55.0 70.0 Ra Plenum 75.7 69.6 Space Plenum Net Percent Space Percent Space Peak Coil Peak Percent Retum 75.7 69.6 Sens. + Lat Sens. + Lat Total Of Total Sensible Of Total Space Sens Tot Sens Of Total Ret/OA 77.7 27.9 Btu/h Btu/h Btu/h ( %) Btu/h ( %) Btu/h Btu/h ( %) Fn MtrTD 0.0 0.0 Envelope Loads Envelope Loads Fn BIdTD 0.0 0.0 Skylite Solar 0 0 0 0 0 0 Skylite Solar 0 0 0.00 Fn Frict 0.0 0.0 Skylite Cond 0 0 0 0 0 0 Skylite Cond 0 0 0.00 Roof Cond 0 0 0 0 0 0 Roof Cond 0 0 0.00 Glass Solar 0 0 0 0 0 0 Glass Solar 0 0 0.00 AIRFLOWS Glass/Door Cond 0 0 0 0 0 0 Glass/Door Cond 0 0 0.00 Wall Cond 0 0 0 0 0 0 Wall Cond 0 0 0.00 Cooling Heating Partition/Door 0 0 0 0 0 Partition/Door 0 0 0.00 Diffuser 195 195 Floor 0 0 0 0 0 Floor 0 0 0.00 Terminal 195 195 Adjacent Floor 0 0 0 0 0 0 Adjacent Floor 0 0 0.00 Main Fan 195 59 Infiltration 0 0 0 0 0 Infiltration 0 0 0.00 Sec Fan 195 195 Sub Total = => 0 0 0 0 0 0 Sub Total =_> 0 0 0.00 Nom Vent 54 54 AHU Vent 54 54 Internal Loads Internal Loads lnfil 0 0 Lights 709 0 709 11 709 16 Lights 0 0 0.00 MinStoplRh 59 59 People 3,460 0 3,460 54 2,119 48 People 2,119 2,119 -72.89 Retum 195 59 Misc 1,500 0 1,500 23 1,500 34 Misc 0 0 0.00 Exhaust 54 54 Sub Total = => 5,669 0 5,669 89 4,328 99 Sub Total = => 2,119 2,119 -72.89 Rm Exh 0 0 Auxiliary 0 0 Ceiling Load 36 -36 0 0 45 1 Ceiling Load -23 0 0.00 Leakage Dwn 0 0 Ventilation Load 0 0 754 12 0 0 Ventilation Load 0 -2,759 94.91 Leakage Ups 0 0 Adj Air Trans Heat 0 0 0 0 0 Adj Air Trans Heat 0 0 0 Dehumid. Ov Sizing 0 0 OvlUndr Sizing 0 0 0.00 Ov /Undr Sizing 0 0 0 0 0 Exhaust Heat 25 -0.86 ENGINEERING CKS Exhaust Heat -39 -39 -1 OA Preheat Diff. 0 0.00 Sup. Fan Heat 0 0 RA Preheat Diff. -2,178 74.91 Cooling Heating Ret. Fan Heat 0 0 0 Additional Reheat 0 0.00 % OA 27.4 27.4 Duct Heat Pkup 0 0 0 System Plenum Heat -114 3.93 cfmfft' 1.13 1.13 Underflr Sup Ht Pkup 0 0 Underflr Sup Ht Pkup 0 0.00 cfmlton 367.40 Supply Air Leakage 0 0 0 Supply Air Leakage 0 0.00 ft'/ton 325.18 Btu/hr•ft 36.90 -16.81 Grand Total => 5,704 -74 6,384 100.00 4,373 100.00 Grand Total => 2,096 -2,907 100.00 No. People 9 COOLING COIL SELECTION AREAS HEATING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR Leave DBIWB/HR Gross Total Glass Capacity Coil Airflow Ent Lvg ton MBh MBh cfm °F °F gr/lb °F °F gr/lb fe ( %) MBh dm °F °F Main Clg 0.5 6.4 4.8 195 77.7 62.8 61.5 55.0 51.5 51.0 Floor 173 Main Htg -1.1 195 65.2 70.0 Aux Clg 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Part 0 Aux Htg 0.0 0 0.0 0.0 Opt Vent 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Int Door 0 Preheat -1.9 54 24.0 55.0 ExFlr 0 Total 0.5 6.4 Roof 0 0 0 Humidif 0.0 0 0.0 0.0 Wall 0 0 0 Opt Vent 0.0 0 0.0 0.0 Ext Door 0 0 0 Total -2.9 Project Name: Dataset Name: 7316986 Sawis.TRC TRACE® 700 v6.2.6.5 calculated at 06:37 AM on 11/09/2011 Altemative - 1 System Checksums Report Page 3 of 3 System Zone Room " Load / Airflow Summary By MACDONALD - MACMILLER Floor Area ft* People Coil Cooling Sensible Btu/h Coil Cooling Total Btu/h Space Design Max SA cfm Air Changes ach /hr VAV Minimum SA cfm VAV Minimum oA Main Coil Heating Sensible Btu /h Heating Fan Percent Max SA OA cfm CIg Htg Alternative 110 -Office Rm Peak 178 1.0 8629 8,947 366 12.35 111 - Office Rm Peak 170 1.0 1,721 1,999 67 2.37 112 - Conference Rm Peak 173 8.7 4,768 6,384 195 6.78 New VAV Zn Peak 521 10.7 14,736 16,948 629 New VAV Zn Block 521 10.7 14,310 16,689 629 (E) AHU -1 Sys Peak 521 10.7 14,736 16,948 629 (E) AHU -1 Sys Block 521 10.7 14,310 16,689 629 • This report does not display heating only systems. Project Name: Dataset Name: 7316986 Sawis.TRC 10 30 -5,129 256 4.3 4.3 20 30 -861 47 22.7 22.7 59 30 -1,048 137 27.4 27.4 30 -7,038 440 13.4 13.4 30 -4,942 440 13.4 13.4 - 7,038 440 13.4 13.4 - 4,942 440 13.4 13.4 TRACE® 700 v6.2.6.5 calculated at 06:37 AM on 11/09/2011 Load/Airflow Summary Report Page 1 of 1 HERMIT COORD CORD PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M11 -170 DATE: 12/02/11 PROJECT NAME: SAVVIS SE2 OFFICE EXPANSION SITE ADDRESS: 12301 TUKWILA INTERNATIONAL BL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DD `PAR MENTS: ` rrm Building ivision 1 Public Works N,4— �)Lrt Fire Prevention Structural Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete DUE DATE: 12/06/11 Not Applicable Comments: Permit Center Use Only • • • INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 01/03/12 Approved ❑ Approved with Conditions g Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only. . CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 Contractors or Tradespeople Peer Friendly Page Page 1 of 2 General /Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name MACDONALD /MILLER FAC SOL INC UBI No. 602254260 Phone 2067684180 Status Active Address Po Box 47983 License No. MACDOFS980RU Suite /Apt. License Type Construction Contractor City Seattle Effective Date 12/31/2002 State WA Expiration Date 12/31/2012 Zip 98106 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company iated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status DIVCOI *988RC DIVCO INCORPORATION Construction Contractor General Unused 12/3/2002 11/7/2012 Active LINFOAR980QG LINFORD AIR >* REFRIGERTN INC Construction Contractor General Unused 11/7/2002 11/7/2004 Archived ENCOMMS984CA ENCOMPASS MECHANICAL SERVICES Construction Contractor General Unused 2/1 /2002 2/1 /2004 Archived MACDOMR026RU MACDONALD MILLER RSDNTL INC Construction Contractor General Unused 12/31 /1998 12/31/2001 Archived DIVCOI *031L4 DIVCO INC Construction Contractor General Unused 6/24/1997 8/1/2003 Archived MACDOMR0760P MACDONALD MILLER RESIDENTIAL L Construction Contractor General Unused 9/17/1993 12/30/1998 Archived DIVCOEC188LC DIVCO ENERGY CONTROL COMPANY Construction Contractor General Unused 6/3/1982 5/26/1997 Archived MACDOM *248J9 MACDONALD MILLER CO Construction Contractor General Unused 4/29/1976 2/1/2002 Archived Business Owner Information Name Role Effective Date Expiration Date GOUGH, DAVID ANTHONY Director 12/29/2010 NOEL, STEPHANIE W Member 05/14/2010 SIMONDS, DERRICK R President 05/14/2010 WEBSTER, MARK E Vice President 05/14/2010 https://fortress.wa.gov/lni/bbip/Print.aspx 12/12/2011 1 J: \731 \6986 Sawis SE2 Offcie Expansion 0 0 N 0 E 0 IL VAV NO. MANUFACTURER & MODEL NO. INLET FAN VALVE CFM HEATER FAN SIZE CFM I MAX ; MIN KW DT CFM VOLT/PH STGS HP VOLT /PH SPD NOTES VAV -201 PRICE FDC5 -2006 6 390 360 80 3 24.3 390 208/3 1/3 115/1 NEW, 1,2 VAV -202 PRICE FDC5 -1005 VAV -203 PRICE FDC5 -1005 40 5 120 1 110 40 5 120 110 0.5 13.2 120 208/1 1/3 115/1 NEW, 1,2 0.5 13.2 120 208/1 1 1/3 115/1 NEW, 1,2 NOTES: 1. DISCONNECT BY ELECTRICAL. 2. SERIES FAN POWERED TERMINAL UNIT WITH HEAT -, SIZE AS LISTED, PRESSURE INDEPENDENT, FACTORY OPTIONS INCLUDE: - ECM MOTOR - CONTROLS ENCLOSURE - EXTENDED DAMPER 1/2" DIAM. SHAFT - FACTORY INSTALLED 1" THROW -AWAY FILTERS - CONTROLS PROVIDED BY OTHERS TO BE MOUNTED IN FIELD. - 3/4" FIBERGLASS UNIT INSULATION - 24V TRANSFORMER, 50 VA MIN RATING, QUIET CONTACTORS (NON MAGNETIC) - AUTO RESET 130 °F HIGH LIMIT TSTAT - DIGITAL CONTROLS BY C.C. NOTE TO ELECTRICAL: - 208V /3PH TERMINAL UNITS REQUIRE A FOUR WIRE POWER FEED IN ORDER TO SUPPLY 115V/1 PH POWER TO THE FAN MOTOR. - 208V/1 PH TERMINAL UNITS REQUIRE A FOUR WIRE WYE IN ORDER TO SUPPLY 115V/1 PH POWER TO THE FAN MOTOR. ABBV FULL NAME ABBV FULL NAME ABBV FULL NAME A AC AFF AL BDD BOB BOD BOTT BTU BTUH BWG BWR C CAP CC CFM CHWR CHWS COMB CONN CWR CWS DB DIFF DMPR DN EC EGC EER ELEV EMS COMPRESSED AIR LINE AIR CONDITIONING UNIT ABOVE FINISHED FLOOR ALUMINUM BACKDRAFT DAMPER BOTTOM OF BEAM BOTTOM OF DUCT BOTTOM BRITISH THERMAL UNITS BRITISH THERMAL UNITS PER HOUR BOTTOM WALL GRILLE BOTTOM WALL REGISTER CONDENSATE CAPACITY CONTROLS CONTRACTOR CUBIC FEET PER MINUTE CHILLED WATER RETURN CHILLED WATER SUPPLY COMBUSTION CONNECT CONDENSER WATER RETURN CONDENSER WATER SUPPLY DUCT BOARD DIFFUSER DAMPER DOWN ELECTRICAL CONTRACTOR EGGCRATE ENERGY EFFICIENCY RATIO ELEVATION ENERGY MANAGEMENT SYSTEM ESP EXH EXTR FAC FD FLA FOB FOT FSD G GALV GC GPM GR GWB HG HP HWR HWS ID INT LIQ M -M MBH MC MCA MD MIN MT MUA NOM EXTERNAL STATIC PRESSURE EXHAUST EXTRACTOR FIRE ALARM CONTRACTOR FIRE DAMPER FULL LOAD AMPS FLAT ON BOTTOM FLAT ON TOP FIRE SMOKE DAMPER GAS LINE GALVANIZED GENERAL CONTRACTOR GALLONS PER MINUTE GRILLE GYPSUM WALL BOARD HOT GAS LINE HORSE POWER HOT WATER RETURN HOT WATER SUPPLY INSIDE DIMENSION INTERLOCK LIQUID LINE MACDONALD- MILLER ONE THOUSAND BTUH MECHANICAL CONTRACTOR MINIMUM CIRCUIT AMPACITY MOTORIZED DAMPER MINIMUM MOUNT MAKE -UP AIR NOMINAL OSA OBD OD RA REG REQ'D RIO SA SCD SD SL SM SP SS SSSC STL SUC SUSP T'STAT TC TOD TOS TV TWG TWR TYP UNO VD VFD 0 OUTSIDE AIR OPPOSED BLADE DAMPER OUTSIDE DIMENSION RETURN AIR REGISTER (GRILLE WITH DAMPER) REQUIRED ROUGH IN ONLY SUPPLY AIR SMOKE CONTROL DAMPER SMOKE DAMPER SOUND LINING SHEET METAL STATIC PRESSURE START /STOP SOLID STATE SPEED CONTROLLER STEEL SUCTION LINE SUSPENDED THERMOSTAT TEMPERATURE CONTROL TOP OF DUCT TOP OF STEEL TURN VANES TOP WALL GRILLE TOP WALL REGISTER TYPICAL UNLESS NOTED OTHERWISE VOLUME DAMPER VARIABLE FREQUENCY DRIVE VOLTAGE PHASE & DUCT DIAMETER SYMBOL FSD -1 1 DESCRIPTION- POWERED 1 1/2 HOUR FIRE/SMOKE DAMPER: LOW VELOCITY, VERTICAL OR HORIZONTAL, 3 -V BLADE,LEAKAGE CLASS 2, 120V ACTUATOR, 2 POSITION, FAIL CLOSED, 165° F FUSABLE LINK, GREENHECK FSD 212 OR EQUAL. 1 1/2 HOUR FIRE/SMOKE DAMPER: MEDIUM VELOCITY, VERTICAL FSD -2 .0. OR HORIZONTAL, AIRFOIL BLADE, LEAKAGE CLASS 2, 120V ACTUATOR, 2 POSITION, FAIL CLOSED, 165° F FUSABLE LINK, GREENHECK FSD 312 OR EQUAL. FSD -3 FSD -4 FSD -5 FSD -6 SD -1 SD -2 MD -1 MD -2 SCD -1 3 HOUR FIRE/SMOKE DAMPER: LOW VELOCITY, VERTICAL OR HORIZONTAL, 3V BLADE, LEAKAGE CLASS 2, 120V ACTUATOR, 2 POSITION, FAIL CLOSED, 165° F FUSABLE LINK, GREENHECK FSD 231 OR EQUAL. 3 HOUR FIRE/SMOKE DAMPER: MEDIUM VELOCITY, VERTICAL OR HORIZONTAL, AIR FOLD BLADE, LEAKAGE CLASS 1, 120V ACTUATOR, 2 POSITION, FAIL CLOSED, 165° F FUSABLE LINK, GREENHECK FSD 311 OR EQUAL 1 1/2 HOUR TUNNEL CORRIDOR FIRE/SMOKE DAMPER: LOW VELOCITY, 3V BLADE, LEAKAGE CLASS 2, 120V ACTUATOR, 2 POSITION, FAIL CLOSED, 165° F FUSABLE LINK, GREENHECK CFSD 212 -1 OR EQUAL. 1 1/2 HOUR OUT OF WALL FIRE/SMOKE DAMPER: LOW VELOCITY, VERTICAL , 3V BLADE, LEAKAGE CLASS 2, 120V ACTUATOR, 2 POSITION, FAIL CLOSED, 165° F FUSABLE LINK, GREENHECK OF SD 212 OR EQUAL. SMOKE DAMPER: GREENHECK SMD 202 OR EQUAL. SMOKE DAMPER: GREENHECK SMD 202 OR EQUAL. MOTORIZED CONTROL DAMPER -LOW VELOCITY GREENHECK VCD -23 OR EQUAL. MOTORIZED CONTROL DAMPER: MEDIUM VELOCITY AIRFOIL BLADES GREENHECK VCD -33 OR EQUAL. SMOKE CONTROL MOTORIZED DAMPER: LOW VELOCITY GREENHECK SMD 202 OR EQUAL. SCD -2 SC SMOKE CONTROL MOTORIZED DAMPER: MEDIUM VELOCITY AIRFOIL BLADE, GREENHECK SMD 301 OR EQUAL NOTES SYMBOL 1,2 1FD -1 1,2 1FD -2 1,2 1,2 1,2 1,2 1,2 1,2 3 4 1,2 1,2 I FD -3 I FD -4 I FD -5 FD -6 BDD BAR DESCRIPTION -NON POWERED 1 1/2 HOUR DYNAMIC FIRE DAMPER: CURTAIN STYLE, VERTICAL OR HORIZONTAL , 165° F FUSABLE LINK, BLADE IN AIR STREAM, GREENHECK DFD 150 TYPE A OR EQUAL. 1 1/2 HOUR DYNAMIC FIRE DAMPER: CURTAIN STYLE, VERTICAL OR HORIZONTAL, 165° F FUSABLE LINK, BLADE OUT OF AIR STREAM, GREENHECK DFD 150 TYPE B OR EQUAL. 3 HOUR DYNAMIC FIRE DAMPER: CURTAIN STYLE, VERTICAL OR HORIZONTAL, 165° F FUSABLE LINK, BLADE IN AIR STREAM, GREENHECK DFD 350 TYPE A OR EQUAL. 3 HOUR DYNAMIC FIRE DAMPER: CURTAIN STYLE, VERTICAL OR HORIZONTAL, 165° F FUSABLE LINK, BLADE OUT OF AIR STREAM, GREENHECK DFD 350 TYPE B OR EQUAL. 1 1/2 HOUR DYNAMIC FIRE DAMPER: LOW VELOCITY, NARROWLINE, VERTICAL - FOR INSTALLATION BETWEEN 2 TRANSFER GRILLES IN A WALL ASSEMBLY, 165° F FUSABLE LINK, GREENHECK DFD -110 OR EQUAL. CEILING RADIATION DAMPER: GREENHECK CRD -2 OR EQUAL. BACKDRAFT DAMPER: GREENHECK WD 330 (VERT) OR WD-100 (HORIZONTAL) OR EQUAL. BAROMETRIC RELIEF DAMPER: (.05 OPNG PRESSURE SHOWN) RUSKIN CBD2. NO SUBSTITUTE ALLOWED. VOLUME DAMPER: SHOP FABRICATED, W/LOCKING QUADRANT. NOTES NOTES: 1. ACTUATOR BY MECHANICAL CONTRACTOR, WIRING BY ELECTRICAL CONTRACTOR 2. INTERLOCK OF SMOKE DAMPER TO FIRE ALARM SYSTEM BY ELECTRICAL CONTRACTOR 3. CONTROL FROM LOCAL DETECTOR 4. CONTROL FROM DUCT DETECTOR 5. OPEN /CLOSED POSITION INDICATOR 6. DAMPER FAILS OPEN 7. DAMPER FAILS CLOSED DESCRIPTION BARE SHEETMETAL SYMBOL I DESCRIPTION 14x12 ROUND SHEETMETAL WRAPPED W/ INSULATION (2 ") SOUNDLINE SHEETMETAL (1" LINING) 14x12SL CLEANROOM QUALITY DUCTWORK SHEETMETAL WRAPPED W/ INSULATION (2 °) 14x12W BARE FLAT OVAL SHEETMETAL SYMBOL 120W 14x12C 14x120 BARE ROUND SHEETMETAL 120 FLAT OVAL FLAT SHEETMETAL WI INSULATION (2 ") 14x 120W EXPOSED QUALITY SHEETMETAL EXAMPLE OF NEW EXAMPLE OF DEMO 14x12Q DUCTBOARD (1" FIBERGLASS) 14x12 EXAMPLE OF NOT IN CONTRACT (NIC) FLEX DUCT 14x12DB 14x12 �r- EXAMPLE OF EXISTING 14X12 FLEX CONNECTOR SYMBOL MANUFACTURER & MODEL NUMBER \/ SIZE A CFM SHOEMAKER 701 -MA SHOEMAKER LSD -LP SHOEMAKER 905 -DW SHOEMAKER 904 M -M METAL EGGCRATE M -M METAL EGGCRATE AS NOTED AS NOTED AS NOTED AS NOTED 12/24 T -BAR LAY -IN MODULAR CORE DIFFUSER SLOT DIFFUSER SURFACE MT RET /EXH GRILLE DOUBLE DEFLECTION SIDEWALL DIFFUSER RETURN /EXH 24/24 RETURN /EXH . THESE PLANS ARE SCHEMATIC AND DO NOT SHOW EXACT ROUTING OR EVERY OFFSET WHICH MAY BE REQUIRED. THE HVAC CONTRACTOR IS TO COORDINATE WITH ALL OTHER TRADES AND IS TO VERIFY ALL CLEARANCES BEFORE COMMENCING WORK. 2. MATERIALS, METHODS, AND INSTALLATION SHALL COMPLY WITH THE PROVISIONS OF THE 2009 EDITIONS OF THE INTERNATIONAL MECHANICAL CODE, INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE AND STATE AND LOCAL CODES AND ORDINANCES. 3. DUCT CONSTRUCTION AND HANGING SHALL COMPLY WITH CHAPTER 6 OF THE 2009 IMC AND WITH CURRENT SMACNA STANDARDS. EARTHQUAKE BRACE ALL DUCTS 28" DIA AND LARGER WHICH ARE SUSPENDED MORE THAN 12" BELOW STRUCTURAL SYSTEM. 4. JOINTS OF MEDIUM AND HIGH VELOCITY DUCT SYSTEMS SHALL BE SEALED WITH GASKETS OR LISTED MASTIC TYPE DUCT SEALANT. 5. DUCTS SHALL BE INSULATED AS INDICATED ON PLANS, PER 2009 WSEC. - DUCT WRAP, WHERE INDICATED, SHALL BE 1 1/2" 0.75 LB /CU FT FIBERGLASS DUCT INSULATION WITH A FACTORY APPLIED REINFORCED ALUM. FOIL VAPOR BARRIER (R-4.2 MIN.). - SOUND LINING, WHERE INDICATED, SHALL BE 1" 1.5 LB /CU FT FIBERGLASS DUCT LINING COATED TO PREVENT FIBER EROSION AT VELOCITIES UP TO 6000 FPM (R-4.2 MIN.). - DUCT BOARD, WHERE INDICATED, SHALL BE 1" RIGID FRK FACED El 475 FIBERGLASS DUCT BOARD SYSTEM, UL 181 LISTED AS A CLASS 1 AIR DUCT (R -4.3 MIN.). AIR DUCT (R-4.3 MIN.). 6. FLEX DUCTS SHALL CONSIST OF A REINFORCED VAPOR BARRIER, 1 1/2" FIBERGLASS INSULATION, AND NON - PERFORATED INTERIOR LINER WITH WIRE HELIX. DUCT SHALL BE A UL 181 LISTED CLASS 1 AIR DUCT. FLEX DUCTS SHALL ONLY BE USED WHERE SHOWN AND SHALL NOT EXCEED 12' IN LENGTH UNLESS NOTED OTHERWISE. 7. PROVIDE EARTHQUAKE RESTRAINT FOR HVAC EQUIPMENT IN ACCORDANCE WITH SECTION 1613 OF THE 2009 IBC. 8. PROVIDE FIRE DAMPERS, SMOKE DAMPERS AND FIRE/SMOKE DAMPERS WHERE INDICATED ON PLANS AND AS REQUIRED BY SECTION 716.5 OF THE 2009 IBC. PROVIDE CEILING FIRE DAMPERS WHERE INDICATED ON PLANS AND AS REQUIRED BY SECTION 716.6.2 OF THE 2009 IBC. INSTALL FIRE DAMPERS SMOKE DAMPERS AND FIRE/SMOKE DAMPERS IN ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS, THE TERMS OF THEIR LISTING, AND THE REQUIREMENTS OF THE CODE. 9. PIPING PENETRATIONS OF FIRE RATED WALLS OR FLOORS SHALL BE SLEEVED AND FIRE STOPPED WITH LISTED MATERIALS SO AS TO MAINTAIN THE INTEGRITY AND RATING OF THE FLOOR OR WALL. 10. PROVIDE RETURN DUCT SMOKE DETECTOR AUTOMATIC SHUT DOWN OF ALL NEW HEATING, COOLING, OR VENTILATION EQUIPMENT MOVING IN EXCESS OF 2000 CFM IN ACCORDANCE WITH SECTION 606 OF THE 2009 IMC. POWER AND INTERLOCK WIRING WITH THE BUILDING FIRE ALARM SYSTEM IS BY THE ELECTRICAL CONTRACTOR. 11. HVAC EQUIPMENT, VALVES AND DAMPERS SHALL BE LOCATED IN EASILY ACCESSIBLE LOCATIONS. UNLESS SHOWN ON ARCHITECTURAL DRAWINGS, REQUIRED ACCESS PANELS SHALL BE PROVIDED AND INSTALLED BY THE GENERAL CONTRACTOR. MINIMUM ACCESStDOOR SIZE FOR VALVES AND DAMPERS TO BE 18" X 18 ". 12. HEAT TRACING OF PIPING, WHERE INDICATED, SHALL BE PROVIDED AND INSTALLED BY THE HVAC CONTRACTOR. THE HVAC CONTRACTOR IS TO COORDINATE THE HEAT TRACE POWER WIRING WITH ELECTRICAL CONTRACTOR. 13. MOTORS STARTERS NOT LISTED AS BEING PROVIDED IN THE HVAC EQUIPMENT SCHEDULES ARE TO BE PROVIDED AND INSTALLED BY ELECTRICAL CONTRACTOR. 14. WITHIN 90 DAYS AFTER THE DATE OF SYSTEM ACCEPTANCE, RECORD DRAWINGS OF THE ACTUAL INSTALLATION TO BE PROVIDED TO THE BUILDING OWNER. RECORD DRAWINGS SHALL INCLUDE AS A MINIMUM THE LOCATION AND PERFORMANCE DATA ON EACH PIECE OF EQUIPMENT, GENERAL CONFIGURATION OF DUCT AND PIPE DISTRIBUTION SYSTEM, INCLUDING SIZES, AND THE TERMINAL AIR AND WATER DESIGN FLOW RATES. 15. OPERATING AND MAINTENANCE MANUALS TO BE PROVIDED TO THE BUILDING OWNER THAT INCLUDE: SUBMITTAL DATA, NAMES AND ADDRESSES OF AT LEAST ONE SERVICE AGENCY, HVAC CONTROLS SYSTEM MAINTENANCE AND CALIBRATION INFORMATION AND A COMPLETE OPERATIONAL NARRATIVE FOR EACH SYSTEM. 16. COMMISSIONING IS REQUIRED ON THIS PROJECT IN ACCORD WITH WASHINGTON STATE ENERGY CODE (WSEC) SECTION 1416 AND WITH LEED NC-2.1 FUNDAMENTAL BUILDING SYSTEMS COMMISSIONING AND ADDITIONAL COMMISSIONING. 17. A COMPLETE REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND FILED WITLLTHE OWNER 18. FOR ALL "SEALED AIR TIGHT" SHAFTS OR ROOMS, THE FOLLOWING MUST OCCUR: - ALL VERTICAL JOINTS INSIDE THE SHAFT SHOULD BE PROVIDED WITH A CONTINUOUS SEAL FOR THE LENGTH OF THE JOINT, INCLUDING THE SHAFT CORNERS (BY GC). - TOP AND BOTTOM WALL TRACKS SHOULD BE CAULKED ALONG THEIR ENTIRE LENGTH (BY GC). - ANY FLOOR DECKING PERPENDICULAR TO THE SHAFT SHOULD BE CAULKED. FILLING WITH ROCK WOOL OR FIRESAFING ("MONOCOAT") IS NOT ACCEPTABLE (BY GC). - ANY PENETRATIONS OF THE SHAFT CONSTRUCTION (DUCTWORK, CONDUIT, PIPING) SHOULD BE SEALED WITH FIRE CAULKING ON BOTH SIDES OF THE PENETRATION. - USE SECTION 909.5 OF THE 2009 IBC FOR MAXIMUM ALLOWABLE LEAKAGE AREA, FOLLOWING THE GUIDELINES FOR SMOKE BARRIER CONSTRUCTION. - ALL DOORS MUST BE PROVIEDED WITH TIGHT FITTING GASKETS, AND OPEN AGAINST THE DIRECTION OF ROOM/SHAFT PRESSURE. 19. DAMPERS USED FOR OUTDOOR AIR INTAKE, EXHAUST, OR RELIEF SHALL HAVE THE FOLLOWING MAXIMUM LEAKAGE RATES AT 1" W.G. (PER AMCA STANDARD 500): MOTORIZED DAMPERS:10 CFM/S.F. GRAVITY DAMPERS: 20CFM /S.F. (40 CFM /S.F. FOR DAMPERS SMALLER THAN 24" IN EITHER DIMENSION). 20. OUTSIDE AIR INTAKE, EXHAUST, AND RELIEF DAMPERS SERVING CONDITIONED SPACES MUST BE MOTORIZED (FAIL CLOSED) PER WSEC 1412.4.1, EXCEPT AS ALLOWED BY WSEC. 21. RETURN AIR SHAFTS TO BE CONSTRUCTED BY THE G.C. TO WITHSTAND A MINIMUM 20 PSF DIFFERENTIAL PRESSURE ACROSS THE WALL. DIFFERENTIAL PRESSURE IS BASED UPON THE MAXIMUM STATIC PRESSURE CAPABILITY OF FAN SYSTEMS SUBJECT TO AUTOMATIC DAMPER CLOSURE. 22. PRESSURIZATION SHAFTS SHALL BE CONSTRUCTED BY THE G.C. AS FOLLOWS: - SHAFTS SERVED BY PRESSURIZATION FANS RATED UP TO 1° STATIC PRESSURE TO BE CONSTRUCTED TO WITHSTAND 10 PSF DIFFERENTIAL PRESSURE. - SHAFTS SERVED BY PRESSURIZATION FANS RATED BETWEEN 1 -2.5" STATIC PRESSURE TO BE CONSTRUCTED TO WITHSTAND 20 PSF DIFFERENTIAL PRESSURE. - FOR SHAFTS SERVED BY PRESSURIZATION FANS RATED ABOVE 2.5" STATIC PRESSURE, CONTACT MECHANICAL ENGINEER. APN# 092304 -9367 LEGAL DESCRIPTION: BEGIN SW CORNER OF N 1/2 OF N 1/2 OF SE 1/4 OF SE 1/4 TH S 89 -30 -18 E 609.74 FT TH N 02 -17 -29 E 323.19 FT TO N LINE OF N 1/2 OF N 1/2 OF SE 1/4 OF SE 1/4 AND S 89 -27 -33 E 614.27 FT FROM NW CORNER OF SAID SE 1/4 OF SE1 /4 TH S 89 -27 -33 E 104.16 FT TO POINT N 89 -27-33 W 300 FT FROM INTERSECTION OF SAID N LINE OF SE 1/4 OF SE 1/4 WITH WLY RNV LINE OF PRIMARY STATE HIGHWAY NO 1 (SR 99) S 118 TH ST TO JCT SSH NO 1 -K APPROVED JULY 23, 1957 TH N 24 -13 -53 W 121.11 FT TH N 63 -55 -24 E 58.16 FT TH N 82 -22 -27 E 64.93 FT TH S 05 -01 -10 E 18A1 FT TH N 7553 -44 E 106.07 FT TH S 78- 38 -58'E 7:83 FT TH N 71 -35-51 E 61.96 FT TH N 73 -32 -42 E 16.58 FT TO POINT ON SAID WLY R/W LINE OF SR 99 THENCE FOLLOWING SAID R/W LINE ALONG ARC OF 2815 FOOT RADIUS NON TANGENT CURVE TO RIGHT, CENTER BEARING S 77 -37 -33 W, THRU C/A OF 4 -04 -51 DISTANCE 200.50 FT TH CONTINUING ON SAID WLY R/W LINE S 12 -22 -27 E 314.17 FT TO POINT ON SAID S LINE OF N 1/2 OF N 1/2 OF SE 1/4 OF SE 1/4 TH N 89- 30 =18 w 488.07 FT TO POINT OF BEGINNING - LOT A OF CITY OF TUKWILA BOUNDARY LINE ADJUSTMENT NO L98 -0033 RECORDING NO 9810059013 DEMO AND CAP DUCTWORK. ADD (3) VAV BOXES AND ASSOCIATED DUCTWORK AND DIFFUSERS. ADD (3) THERMOSTATS. TITLE HVAC ENGINEER ACCOUNT EXECUTIVE NAME JASON LIENING STEVE FLINK COMPANY. MACDONALD MILLER MACDONALD MILLER PHONE NUMBER 206 -768 -3892 253 -680 -3172 EMAIL JASON. LIEN ING @MACM ILLER.COM STEVE.FLINK @MACM ILLER.COM NAME TITLE TM0.01 SCHEDULES - HVAC TM0.02S SITE MAP 0 Mchanical Ertecbical gerkirribing &Kim Piping City of Tukwila DIVISION REVISIONS No changes shall be made to the scope of wok` without prior approval of Tzikry is Building Division- , ^ s will require a new plan submittal c:r.:1 may include additional plan review fees. TITLE 1ST FLOOR PARTIAL DEMO PLAN - HVAC 1ST FLOOR PARTIAL PLAN - HVAC 12301 TUKWILA INTERNATIONAL BLVD TUKWILA, WA VICINITY MAP NO SCALE REVIEWED FOR CODE COMPLIANCE APPROVED DEC 0 9 2011 V-- VU►� City of Tukwila BUILDING DIVISION FIL COPY Permit No. pl^ trview approval is subject to errors and omens. . ; rI �: of construction documents does not authorize ot any adopted code or ordinance. Receipt (' Lpp ove;O Fled Copy and cuiditions is ac knowledgod: By Die: __ `z/iz /ii City Of Tukwila BUILDING DIVISION MII CITYOF T K ML4 DEC 022011 PERMIT CENTER 110 1433 O co w a)cfl . - Z < co 2 1.9 �N o 0 1 D N -a u) u_ CO 3O O Q Qm ti \V QN LL g 2 ‘1.7_ .macmiller.com I I I 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 I N N z 0 ( ) z 0 X 0 w w LL J U_ J L o Z N w c0 w Z� ao° J I <<0 ENGINEER: J LIENING CHECKED BY: B GEZON CAD: J HACKNEY DRAWING NUMBER: WA Lic No: MACDOFS980RU EXPIRES: 07 -06 -12 0 REVISIONS: w 0 Q REVISIONS: z 0 U LL () z 0 U 0 u_ 0 w C!) (I) LAST REVISED: 11 -22 -11 DATE PLOTTED: 11 -22 -11 ISSUE DATE: 11 -22 -11 D-1196-7316986-00 SHEET NUMBER: TM0.01 J: \731 \6986 Sawis SE2 Offcie Expansion 2 :23:19 PM C C ithl7° REVIEWED FOR CODE COMPLIANCE APPROVED DEC 0 9 2011 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA DEC 0 2'2011 PERMIT CENTER L N Q) _ z „:9_ 0 I o O" Q 0 Li- E U N U t0 E 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 O co O U_ 0 0 0 CQ G O z -0 J EXPIRES: 07 -06 -12 W 0 REVISIONS: 1 1 1 1 1 1 1 NI Q N 0 ENGINEER: J LIENING CHECKED BY: B GEZON REVISIONS: Z 0 U 1- u) Z 0 U 0 LL 0 W LAST REVISED: 11 -22 -11 DATE PLOTTED: 11 -22 -11 CAD: ISSUE DATE: J HACKNEY 11-22-11 DRAWING NUMBER: D- 1196- 7316986 -00 SHEET NUMBER: TM0.01 S 2:23:29 PM N N 2 E 0 Z O L A ■ rTh r 71 EXIST. ELEV. EQUIP. RM. .............. . 4x24... EC -48x24 DT6 -1279 CONTROL DAMPER MOTOR COMROL CONTRACTOR (DIIdAY }_. FAX' COPIER! PRINTER 22 "0 014 -400 901C- W12x19 MEN CONFERENCE 11121 EXIST. ATCHEN -1 T3- 3111xisT) OPEN OFFICE OFFI(: EMT. CONFERENCE HA!L x120 1' 56 ". _. EC -24x24 EXIST. SECURITY - I D761-11336 EC -24x24 RAMP DN @ 1 : 12 WO 0 REVIEWED FOR CODE COMPLIANCE APPROVED DEC 092011 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA DEC 022011 PERMIT CENTER EB'z 1 /8" = 1' -0" ^_ W =z O uu rt0 .macmiller.com 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 :=1 cV (.1 N 0 0 W 0_ I I I I I I l< Z 0 V ) Z 0 X 0 W W FCII U_ J LL LL 0 O N w W z� • ��/ r � Q � v/ J� (1) 5 >>. 12 w VJCV12 ENGINEER: J LIENING CHECKED BY: B GEZON CAD: J HACKNEY DRAWING NUMBER: H WA Lic No: MACDOFS980RU EXPIRES: 07 -06 -12 0 REVISIONS: Id 0 REVISIONS: Z 0 U Z 0 U 0 I_ 0 W C!) U) LAST REVISED: 11 -22 -11 DATE PLOTTED: 11 -22 -11 ISSUE DATE 11 -22 -11 D- 1196 - 7316986 -00 SHEET NUMBER: DM2.01 2:23:27 PM 0 E A (8 x!sr ELEV. EQUIP. RM. EC- 48x24 DT6 -1279 FAX, COPIER' _PRINTER. COtf1ROL DAMPER MOTOR BY, CONTROL CONTRACTOR;(DIMAY) 2.." 12'0 _ 22 -12 °0 T012' -1' BO11' -1" 120' s Mull 14 °0 T©12 2° 14.0._ @11 - DOA_P u (wP_3). 8x8 0 1.20 EXIST. MEN EI ST.. WOMEN L-1 Il �i ilionanal IUD►► liff V-203 EXIST. KITCHEN 1 -I EXIST :DT3 -30ST OFEN OFFICE DT3 -300 VAV- 202 EXIST. LOBBY 1 - -I EXIST. CONFERENCE FXIST. SECURITY I - I EC -24x24 DT3 EXIST. PORTAL. -I EC -24x24 12x121 1390 EXIST. LOBBY 1 -I 1 RAMP DN @1:'i2 EC -12x24 0 REVIEWED WED FOR CODE COMPLIANCE APPROVED DEC 09 2011 City of Tukwila BUILDING DIVISION RECEIVED. CITY OF TUKWILA DEC 022011 PERMIT CENTER ea'z 1/8" = 1' -0" 4 ITY SOLUTIONS o� co co rn < (0 0 ao 0 a)c' E (n ED ic o LL 4) as U 0 U CO o0Q a) m CV 0 Is- 0_ 1 1 1 1 1 1 1 1 EXPIRES: 07 -06 -12 W 0 REVISIONS: 1 1 1 1 1 1 1 NI N 0 0 (S) W D_ I I I I I 111 z 0 V z 0 W W 0 REVISIONS: z 0 U °> ry J m 1— _ J u_ z z LL ° 0 O z ;ha v W'' Et W ~ Ce o 0 0 Lim 0 D << 7;1 w w 2 12 u) ENGINEER: J LIENING CHECKED BY: B GEZON CAD: J HACKNEY LAST REVISED: 11 -22 -11 DATE PLOTTED: 11 -22 -11 ISSUE DATE: 1 1 —22-11 DRAWING NUMBER: D-1196-7316986-00 SHEET NUMBER: TM2.01