HomeMy WebLinkAboutPermit M11-180 - GROUP HEALTH - AMB PHARMACYGROUP HEALTH 12501 EAST MARGINAL WY S Ml 1 -180 City okukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov MECHANICAL PERMIT Parcel No.: 7345600385 Address: 12501 EAST MARGINAL WY S TUKW Project Name: GROUP HEALTH - AMB PHARMACY Permit Number: M11 -180 Issue Date: 01/06/2012 Permit Expires On: 07/04/2012 Owner: Name: INTERNATIONAL GATEWAY EAST LLC Address: 12201 TUKWILA INTRNTNL BLVD 4TH FL , SEATTLE WA 98168 5121 Contact Person: Name: GEORGE GRAHAM Address: 7717 DETROIT AV SW , SEATTLE WA 98106 Email: GEORGE.GRAHAM @MACMILLER.COM Contractor: Name: MACDONALD /MILLER FAC SOL INC Address: PO BOX 47983 , SEATTLE, WA 98106 Contractor License No: MACDOFS980RU Phone: 206 768 -4288 Phone: 206 - 768 -4180 Expiration Date: 12/31/2012 DESCRIPTION OF WORK: INSTALL (3) FAN POWERED VAV BOXES WITH ELECTRIC HEAT, INSTALL (11) DIFFUSER/GRILLES, AND RELOCATE (110)DIFFUSER/GRILLES WITH MISCELLANEOUS DUCTWORK. Value of Mechanical: $26,000.00 Type of Fire Protection: UNKNOWN Electrical Service Provided by: Permit Center Authorized Signature: Fees Collected: $502.06 International Mechanical Code Edition: 2009 Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this pe Signature: Print Name: Date: /% (/ — - This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -4/10 M11-180 Printed: 01 -06 -2012 • • PERMIT CONDITIONS Permit No. M11 -180 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IMC -4/10 M11-180 Printed: 01 -06 -2012 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwita.wa.us SITE LOCATION Mechanical Permit No. Project No. Nil (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *please print ** King Co Assessor's Tax No.• 7340600480 Site Address: 12501 E MARGINAL WAY TUKWILA, WA 98168 Suite Number: RX Tenant Name: GROUP HEALTH - AMB PHARMACY Property Owners Name: GROUP HEALTH Mailing Address: PO BOX 34919 Floor: 2 New Tenant: ❑ Yes ❑..No SEATTLE City WA 98124 State Zip CONTACT PERSON — who do we contact when your permit is ready to be issued Name: GEORGE GRAHAM Mailing Address: 7717 DETROIT AVE SW Day Telephone: (206) 768 -4288 SEATTLE WA 98106 E -Mail Address: GEORGE.GRAHAM @MACMILLER.COM City State Fax Number: (206) 7684289 Zip MECHANICAL CONTRACTOR INFORMATION Company Name: MACDONALD MILLER Mailing Address: 7717 DETROIT AVE SW SEATTLE WA 98106 Contact Person: DARLA DOLL E -Mail Address: DARLA.DOLL @MACMILLER.COM Contractor Registration Number: MACDOFS980RU City State Day Telephone: (206) 7684278 Fax Number: (206) 768 -4279 Expiration Date: 12/31/2012 Zip ARCHITECT OF RECORD — All plans must be stamped by architect of record Company Name: N/A Mailing Address: Contact Person: E -Mail Address: City Day Telephone: Fax Number: State Zip ENGINEER OF RECORD— All plans must be stamped by engineer of record Company Name: MACDONALD MILLER Mailing Address: 7717 DETROIT AVE SW Contact Person: GEORGE GRAHAM SEATTLE WA 98106 E -Mail Address: GEORGE.GRAHAM @MACMILLER.COM H:\Applications \Forms - Applications On Line\2010 Applications \7 -2010 - Mechanical Permit Application.doc Revised: 7 -2010 bh City State Day Telephone: (206) 768 -4288 Fax Number: (206) 768 -4289 Zip Page 1 of 2 Valuation of project (contractor's bid price): $ 26,000.00 Scope of work (please provide detailed information): INSTALL (3) FAN POWERED VAV BOXES W/ ELECTRIC HEAT, INSTALL (11) DIFFUSER/GRILLES, RELOCATE (11) DIFFUSER/GRILLES AND MISC DUCTWORK. Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement Fuel Type: Electric Gas Other: Indicate type of mechanical work being installed and the quanfty below: Unit Type: Qty Unit Type: Qty Unit Type: Qty Bioler /Compressor Qty furnace <100k btu air handling unit >10,000 cfm fire damper 0 -3 hp /100,000 btu furnace >100k btu evaporator cooler 22 diffuser 3 -15 hp /500,000 btu floor furnace ventilation fan connected to single duct thermostat 15 -30 hp /1,000,000 btu suspended/wall /floor mounted heater ventilation system wood/gas stove 30 -50 hp /1,750,000 btu appliance vent hood and duct emergency generator 50+ hp /1,750,000 btu repair or addition to heat/refrig/cooling system Incinerator — domestic other mechanical equipment air handling unit <10,000 cfm 3 incinerator — comm /ind PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 international building code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OR AUTHORIZED AGENT: Signature: '— c Print Name: DARLA DOLL Mailing Address: 7717 DETROIT AVE SW Date Application Accepted: (/1 122 I i Date: 12/22/2011 Day Telephone: (206) 768 -4278 SEATTLE City Date Application Expires: ilia WA 98106 State Zip H:\Applications \Forms - Applications On Line\2010 Applications \7 -2010 - Mechanical Permit Application.doc Revised: 7 -2010 bh Staff Initials: Page 2 of 2 • City of Tukwila 0 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov RECEIPT Parcel No.: 7345600385 Permit Number: M11 -180 Address: 12501 EAST MARGINAL WY S TUKW Status: PENDING Suite No: Applied Date: 12/22/2011 Applicant: GROUP HEALTH - AMB PHARMACY Issue Date: Receipt No.: R11 -02777 Payment Amount: $502.06 Initials: JEM Payment Date: 12/22/2011 01:00 PM User ID: 1165 Balance: $0.00 Payee: MACDONALD- MILLER FACILITY SOLUTIONS, INC. TRANSACTION LIST: Type Method Descriptio Amount Payment Check 3198 502.06 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts MECHANICAL - NONRES PLAN CHECK - NONRES 000.322.102.00.00 401.65 000.345.830 100.41 Total: $502.06 doc: Receipt -06 Printed: 12 -22 -2011 INSPECTION NO. INSPECTION RECORD Retain a copy with permit IM!( -lea PERMIT NO. . CITY_OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -367 Permit Inspection Request Line (206) 431 -2451 Project � ,4 z.;-/-/- Type on` pectiosn:�. Ue Address: I12-S 13 ( g . 6:4-i Date Called: Special Instructions: Date Wanted • ' 2' l� r . ...a.02: p.m. P.m. Requester: Phone No: (a -35/ 43 pproved per.applicable codes. 0-Corrections required prior to approval. COMMENTS: 7iNty. r-1 (d , fele Inspec n Date: EINSPECTIO FEE REQUIRED. Prior to next • spection. fee must be aid at 6300 5 , uthcenter Blvd.. S ite 100. Call to schedule reinspection. • • - • • • • • ;E! ' • - INSPECTION RECORD - Retain a copy with permit f27'47‘.-/ 8 INSPECTION NO. PERMIT NO. CITY OF=TUKWILA BUILDING DIVISION 6300'Southcenter Blvd.., #100, Tukwila. WA 98188 R (206) 431 -3670, Permit InspectidmRequest Line (206) 431 -2451 Project: Type of Inspection: - �• Address. 5� ,9 614/rgL Date Called: Special Ifistructions: a/9 ... • • -- . ._. 407828 -O/ Date Wanted:. a a 7- /2_ (ate,. p.m. Requester: Phone No: eReG - 9 J 7o2, •pproved per applicable codes. (•Corrections required prior to approval. COMMENTS:: • t E)NSPECTI'ON FEE RE � UIRED. Pri r to next inspection. fee must be id at 6300'Southcenter Blvd.. Suite 100..Call to schedule reinspection. MacDonald- Miller FACILITY SOLUTIONS pin- /so Group Health -AMB Pharmacy FIRM: MacDonald - Miller 7717 Detriot Ave. SW Seattle, WA 98106 PHONE: (206) 763 -9400 FAX: (206) 768 -3991 PROJECT: Group Health AMB Pharmacy FL2 12501 East Marginal Way Tukwila WA 98168, WA DATE: 3/1/2012 PROJECT #: 7317040 CONTACT: NOTES: MacDonald - Miller NEBB Certified TAB Contractor Instrument MacDonald - Miller FACILITY SOLUTIONS MacDonald Miller Facility Solutions Calibration Certification 2012 Calibration Tool# Model# Serial# By Calibration Date Calibration Due Rotating Measurement 1003510 Extech 461995 Q342831 Davis Inotek 6/25/2011 • :.6/25/2012 Temperature Measurement Air 1008156 ADM -860C M11766 Shortridge 11/25/2011 0.,1:1/25/2012 • Temperature Measurement H2O 5262883 Mac 63690 1555257 Davis Inotek 6/27/2011 • ` "' 1� 6/27/2012 Electrical Measurement 1003918 Fluke 902 94710185 Davis Inotek 6/25/2011 6/25/2012 Temperature Measurement Air 1008156 ADM -860C M11766 Shortridge 11/25/2011 11/25/2012 Air Velocity Measurement 1005876 TSI 9555 -P 9555P0841039 TSI 7/8/2011 7/8/2012 Temperature Measurement Air 1008156 ADM -860C M11766 Shortridge 11/25/2011 11/25/2012 Humidity Measurement BW IA0920 IAQ920711015 TSI 10/19/2011 "10/19/2012 Hydronic Pressure Measurement 1008161 HM670 71139011 Alnore 10/7/2011 1.0/7/2012 Hydronic Differential Pressure Measurement 1008161 HM670 71139011 Alnore 10/7/2011 10/7/2012 11/28/2011 S: \FieldEng \NEBB_TAB(D) \Tools \Calibration Certification MacDonald- Miller FACILITY SOLUTIONS GROUP HEALTH AMB PHARMACY JOB # 731 -7040 1) General Notes a) HVAC balancing was completed 2/29/12. b) Design information was obtained from mechanical drawings. c) TAB work was in accordance with NEBB procedural standards. d) Outlet volumetric flow rates were measured by use of a calibrated Flow Hood. 2) Scope of work a) Test, Adjust and Balance 11 terminal units 3 of which are new. 3) Description of the System a) Controls (Direct Digital Controls — DDC) i) Siemens b) Terminal Units i) VAV's (1) Existing units are TempMaster variable air volume units with SCR controlled constant volume motors. (2) New units are Envirotech variable air volume units with variable speed ECM motors. (3) Both are Series fan powered pressure independent 4) TAB Procedures Summarized a) Terminal Units i) VAV's (1) Flow Ring Calibration (a) entered unit's design set points and sizing into DDC (b) placed unit to full cooling (c) measured inlet velocity pressure at the flow ring (i) adjusted multiplier to calibrate CFM (2) Setting unit's fan for total flow (a) Existing units (i) measured the sum total of the outlets (ii) increased or decreased the fan motor's SCR setting until design total flow was achieved (b) New Units (i) Measured the sum of the outlets. (ii) Increased or decreased the VDC signal to the ECM motor until correct airflow was achieved (3) Outlet Proportioning (a) while unit still in full cooling mode, the outlets are then proportioned (4) Checking Minimum Primary Air Flow (a) placed unit to minimum primary flow (b) measured inlet velocity pressure at the flow ring (5) Heating coil testing (as equipped) (a) While the unit was still at minimum flow, the thermostat's temperature set point was lowered to less than room temperature to force the unit's heating coil on, the heaters delta T was then recorded. The new VAV's had amps and volts recorded. (6) Verified minimum Fan Flow on new VAV's (a) Adjusted the temperature set point until the unit went into dead band mode causing the fan to be at its minimum speed. (b) Verified and recorded the fan speed. (7) Reset overrides to normal operating condition. Project Manager: Ruben Canas Field Technician: Noah Walker tali> MacDonald- Miller FACILITY SOLUTIONS Air Handling Unit PROJECT: Group Health AMB Pharmacy FL2 LOCATION: Tukwila WA 98168, WA PROJECT #: 7317040 DATE: 3/1/2012 CONTACT: I SYSTEM /UNIT: AHU -01 / VAV -214 AREA: Un Data Manufacturer Model Number VAV Address Box Inlet Size K Factor Tempmaster HFSL -A 20 10" 0.72 AHU -01 / VAV -214 Supply Outlet Summary REF # 2 Tested By: Noah Walker Test Date: February 29, 2012 Term Box Test Data Max Design CFM Max Actual CFM Max Setpoint Min Design CFM Min Actual CFM Min Setpoint Max Diff. SP Min Diff. SP Reheat Design CFM Reheat Actual CFM VAV Delta T Filter Size 640 CFM 655 CFM 640 140 CFM 140 CFM 140 0.1820 in. we 0.0090 in. we 870 CFM 900 CFM 27 Deg F 16x24x1 inches System / Unit T/O Type of Reading Outlet Type Size Design Reading Prelim Reading °to Pre Final Reading % Final Outlet -01 Flow Hood CD 10X10 190 190 100 185 97 Outlet -02 T Flow Hood CD 10X10 190 160 84 195 103 Outlet -03 0 Flow Hood CD 8X8 190 75 39 205 108 Outlet -04 Flow Hood CD 6x6 100 50 50 105 105 Outlet -05 Flow Hood CD 10x10 100 75 75 105 105 Outlet -06 Flow Hood CD 6X6 100 30 30 105 105 Totals : 870 560 67 °% -' 900 103 °% * Notes AHU -01 / VAV -214 29- Feb -12 Noah Walker Unable to communicate to unit thru the T -stat. Plugged directly into card. MacDonald- Miller NEBB Certified TAB Contractor Page 1 of 10 MacDonald- Miller FACILITY SOLUTIONS Air Handling Unit PROJECT: Group Health AMB Pharmacy FL2 LOCATION: Tukwila WA 98168, WA PROJECT #: 7317040 DATE: 3/1/2012 CONTACT: SYSTEM /UNIT: AHU -01 / VAV -215 AREA: Unit Data Manufacturer Model Number VAV Address Box Inlet Size K Factor Tempmaster HFSL -E 27 10" 0.70 AHU -01 / VAV -215 Supply Outlet Summary REF # 3 Tested By: Noah Walker Test Date: February 28, 2012 Term Box Test Data Max Design CFM Max Actual CFM Max Setpoint Min Design CFM Min Actual CFM Min Setpoint Max Diff. SP Min Diff. SP Reheat Design CFM Reheat Actual CFM VAV Delta T Filter Size 590 CFM 585 CFM 592 140 CFM 145 CFM 140 0.1550 in. wc 0.0090 in. wc 660 CFM 695 CFM 32 Deg F 16x24x1 inches System 1 Unit - T10 Type of Reading Outlet Type Size Design;,, Reading Prelim Reading % Pre Final < Reading % Final Outlet -01 Flow Hood CD 8X8 180 190 106 190 106 Outlet -02 0 Flow Hood CD 8X8 160 190 119 165 103 Outlet -03 Flow Hood CD 8X8 160 195 122 170 106 Outlet -04 T Flow Hood CD 8X8 160 230 144 170 106 Totals : 660 805 122 % 695 105 % * Notes MacDonald- Miller NEBB Certified TAB Contractor Page 2 of 10 CZ)MacDonald- Miller FACILITY SOLUTIONS Air Handling Unit PROJECT: Group Health AMB Pharmacy FL2 LOCATION: Tukwila WA 98168, WA PROJECT #: 7317040 DATE: 3/1/2012 CONTACT: SYSTEM /UNIT: AHU -01 / VAV -216 AREA: Unit Data Manufacturer Model Number VAV Address Box Inlet Size K Factor Tempmaster HFSL -F 28 12" 0.69 AHU -01 / VAV -216 Supply Outlet Summary REF # 4 Tested By: Noah Walker Test Date: February 28, 2012 Term Box Test Data Max Design CFM 855 CFM Max Actual CFM 865 CFM Max Setpoint 856 Min Design CFM 220 CFM Min Actual CFM 240 CFM Min Setpoint 220 Max Diff. SP 0.1860 in. wc Min Diff. SP 0.0120 in. wc Reheat Design CFM 940 CFM Reheat Actual CFM 940 CFM Filter Size 16x32x1 inches System 1 Unit T/O Type of Reading Outlet Type Size Design! Reading Prelim Reading % Pre Final Reading % Final Outlet -01 Flow Hood CD 12X12 235 435 185 235 100 Outlet -02 T Flow Hood CD 12X12 235 445 189 245 104 Outlet -03 Flow Hood CD 12X12 235 100 43 240 102 Outlet -04 0 Flow Hood CD 12X12 235 420 179 220 94 Totals : 940 1,400 149 % 940 100 °%o * Notes MacDonald- Miller NEBB Certified TAB Contractor Page 3 of 10 MacDonald- Miller FACILITY SOLUTIONS Air Handling Unit PROJECT: Group Health AMB Pharmacy FL2 LOCATION: Tukwila WA 98168, WA PROJECT #: 7317040 DATE: 3/1/2012 CONTACT: SYSTEM /UNIT: AHU -01 / VAV -217 AREA: unit D Manufacturer Model Number VAV Address Box Inlet Size K Factor Tempmaster HFSL -F 19 12" 0.70 AHU -01 / VAV-217 Supply Outlet Summary REF # 5 Tested By: Noah Walker Test Date: February 28, 2012 Ti rm' Box Test Data Max Design CFM Max Actual CFM Max Setpoint Min Design CFM Min Actual CFM Min Setpoint Max Diff. SP Min Diff. SP Reheat Design CFM Reheat Actual CFM VAV Delta T 1090 CFM 1100 CFM 1092 220 CFM 225 CFM 220 0.3030 in. we 0.0120 in. we 1200 CFM 1190 CFM 22 Deg F System f Unit T/O Type of Reading Outlet Type Size Design Reading Prelim Reading % Pre Final Reading % Final Outlet -01 T Flow Hood CD 12X12 300 385 128 295 98 Outlet -02 Flow Hood CD 12X12 300 385 128 295 98 Outlet -03 0 Flow Hood CD 12X12 300 370 123 290 97 Outlet -04 Flow Hood CD 12X12 300 390 130 310 103 Totals : 1,200 ` 1,530 128 % ^ 1,190 99i% * Notes MacDonald- Miller NEBB Certified TAB Contractor Page 4 of 10 MacDonald- Miller FACILITY SOLUTIONS Air Handling Unit PROJECT: Group Health AMB Pharmacy FL2 LOCATION: Tukwila WA 98168, WA PROJECT #: 7317040 DATE: 3/1/2012 CONTACT: SYSTEM /UNIT: AHU -01 / VAV -218 AREA: Unit Data Manufacturer Tempmaster Model Number HFSL -E VAV Address 18 Box Inlet Size 10" K Factor 0.71 AHU -01 / VAV -218 Supply Outlet Summary REF # 6 Tested By: Noah Walker Test Date: February 29, 2012 Term Box Test Data Max Design CFM 1100 CFM Max Actual CFM 1100 CFM Max Setpoint 1100 Min Design CFM 180 CFM Min Actual CFM 190 CFM Min Setpoint 180 Max Diff. SP 0.5380 in. wc Min Diff. SP 0.0140 in. wc Reheat Design CFM 1215 CFM Reheat Actual CFM 1235 CFM VAV Delta T 19 Deg F Filter Size 16x24x1 inches System I Unit TIO Type of Reading Outlet Type Size Design Reading Prelim Reading % Pre Final Reading % Final Outlet -01 T Flow Hood CD 12X12 300 215 72 310 103 Outlet -02 Flow Hood CD 12X12 300 405 135 315 105 Outlet -03 Flow Hood CD 8X8 75 185 247 80 107 Outlet -04 Flow Hood CD 8X8 180 235 131 175 97 Outlet -05 0 Flow Hood CD 12X12 360 450 125 355 99 Totals : 1,215= 1,490 123 % 1,235 102 % * Notes MacDonald-Miller NEBB Certified TAB Contractor Page 5 of 10 Crirj) MacDonald -Miller FACILITY SOLUTIONS Air Handling Unit PROJECT: Group Health AMB Pharmacy FL2 LOCATION: Tukwila WA 98168, WA PROJECT #: 7317040 DATE: 3/1/2012 CONTACT: SYSTEM /UNIT: AHU -01 / VAV -220 AREA: Unit Data Manufacturer Model Number VAV Address Box Inlet Size K Factor Tempmaster HFSL -A 12 5" 0.81 AHU -01 / VAV -220 Supply Outlet Summary REF # 7 Tested By: Noah Walker Test Date: February 29, 2012 Term Box Test D lta Max Design CFM Max Actual CFM Max Setpoint Min Design CFM Min Actual CFM Min Setpoint Max Diff. SP Min Diff. SP Reheat Design CFM Reheat Actual CFM VAV Delta T Filter Size 165 CFM 165 CFM 164 145 CFM 145 CFM 144 0.1940 in. wc 0.1500 in. wc 275 CFM 280 CFM 16 Deg F 14x20x1 inches System I Unit TIO Type of Reading Outlet Type Size Design Reading Prelim Reading % Pre Final Reading % Final Outlet -01 T/O Flow Hood CD 10x10 275 350 127 280 102 To is : - - - 275 350 127 % 280 + 102 %` * Notes SYSTEM /UNIT: AHU -01 / VAV -221 AREA: Unit Dat Manufacturer Model Number VAV Address Box Inlet Size K Factor Tempmaster HFSL -A 13 5" 0.74 AHU -01 / VAV -221 Supply Outlet Summary REF # 8 Tested By: Noah Walker Test Date: February 29, 2012 Term Box Test Data Max Design CFM Max Actual CFM Max Setpoint Min Design CFM Min Actual CFM Min Setpoint Max Diff. SP Min Diff. SP Reheat Design CFM Reheat Actual CFM VAV Delta T Filter Size 165 CFM 165 CFM 164 145 CFM 145 CFM 144 0.1940 in. wc 0.1500 in. wc 275 CFM 285 CFM 15 Deg F 14x20x1 inches System / Unit T/p Type of Reading Outlet Type Size Design Reading Prelim Reading % Pre Final ; Reading % Final Outlet -01 T/O Flow Hood CD 10x10 275 300 109 285 104 Totals : 275 300 109 % 285 ` 104 % z' * Notes MacDonald - Miller NEBB Certified TAB Contractor Page 6 of 10 MacDonald- Miller FACILITY SOLUTIONS Air Handling Unit PROJECT: Group Health AMB Pharmacy FL2 LOCATION: Tukwila WA 98168, WA PROJECT #: 7317040 DATE: 3/1/2012 CONTACT: SYSTEM /UNIT: AHU -01 / VAV -222 AREA: Unit Data Manufacturer Model Number VAV Address Box Inlet Size K Factor Tempmaster HFSL -E 14 10" 0.71 AHU -01 / VAV -222 Supply Outlet Summary REF # 9 Tested By: Noah Walker Test Date: February 29, 2012 Term Box Test Data Max Design CFM 645 CFM Max Actual CFM 660 CFM Max Setpoint 644 Min Design CFM 180 CFM Min Actual CFM 190 CFM Min Setpoint 180 Max Diff. SP 0.1820 in. wc Min Diff. SP 0.0140 in. wc Reheat Design CFM 710 CFM Reheat Actual CFM 735 CFM Filter Size 16x24x1 inches System I Unit TIO Type of Reading Outlet Type Size Design Reading Prelim Reading °l° Pre Final Reading % Final Outlet -01 Flow Hood CD 8X8 210 290 138 225 107 Outlet -02 0 Flow Hood CD 8X8 210 265 126 205 98 Outlet -03 Flow Hood CD 8X8 210 320 152 220 105 Outlet -04 T Flow Hood CD 8X8 80 135 169 85 106 Totals : 710 1,010 142 % - 735 104 % * Notes MacDonald- Miller NEBB Certified TAB Contractor Page 7of 10 MacDonald- Miller FACILITY SOLUTIONS Air Handling Unit PROJECT: Group Health AMB Pharmacy FL2 LOCATION: Tukwila WA 98168, WA PROJECT #: 7317040 DATE: 3/1/2012 CONTACT: SYSTEM /UNIT: AHU -01 / VAV -223 AREA: Unit Data Manufacturer Enviro -Tec Model Number CVFQ-0811E Serial Number 111222 -21 VAV Address 26 Box Inlet Size 8" K Factor 0.47 AHU -01 / VAV -223 Supply Outlet Summary REF # 10 Tested By: Noah Walker Test Date: February 29, 2012 Term Box Test Data Max Design CFM 440 CFM Max Actual CFM 430 CFM Max Setpoint 440 Min Design CFM 150 CFM Min Actual CFM 145 CFM Min Setpoint 152 Max Diff. SP 0.2420 in. wc Min Diff. SP 0.0280 in. wc Reheat Design CFM 490 CFM Reheat Actual CFM 480 CFM VAV Delta T 32 Deg F ECM Fan Voltage 3.01 VDC Filter Size 12.75x13.75x1 inches System/ Unit TIO Type of Reading Outlet Type Size Design Reading Prelim Reading % Pre Final Reading % Final Outlet -01 T Flow Hood CD 10X10 245 345 141 235 96 Outlet -02 0 Flow Hood CD 10X10 245 300 122 245 100 Totals : 490 - 645 132 % 480 ! 98% * Notes AHU -01 / VAV -223 29- Feb -12 Noah Walker Min fan speed 200 CFM. Actual is 210. MacDonald- Miller NEBB Certified TAB Contractor Page 8 of 10 CZ,MacDonald- Miller FACILITY SOLUTIONS Air Handling Unit PROJECT: Group Health AMB Pharmacy FL2 LOCATION: Tukwila WA 98168, WA PROJECT #: 7317040 DATE: 3/1/2012 CONTACT: SYSTEM /UNIT: AHU -01 / VAV -224 AREA: Unit Data Manufacturer Model Number Serial Number VAV Address Box Inlet Size K Factor Enviro -Tec CVFQ -0811 E 111222 -21 27 8" 0.41 AHU -01 / VAV -224 Supply Outlet Summary REF # 11 Tested By: Noah Walker Test Date: February 29, 2012 Term Box Test Data Max Design CFM 705 CFM Max Actual CFM 705 CFM Max Setpoint 705 Min Design CFM 240 CFM Min Actual CFM 240 CFM Min Setpoint 240 Max Diff. SP 0.6200 in. wc Min Diff. SP 0.0720 in. wc Reheat Design CFM 780 CFM Reheat Actual CFM 820 CFM VAV Delta T 19 Deg F ECM Fan Voltage 9.0 VDC Filter Size 12.75x13.75x1 inches System / Unit T/O Type of Reading Outlet Type Size Design Reading Prelim Reading % Pre Final Reading % Final Outlet -01 T Flow Hood CD 8X8 195 205 105 205 105 Outlet -02 Flow Hood CD 8X8 195 210 108 210 108 Outlet -03 0 Flow Hood CD 8X8 195 200 103 200 103 Outlet -04 Flow Hood CD 8X8 195 210 108 205 105 Totals : - - - 780 ` 825 106 % ' 820 105 % * Notes MacDonald-Miller NEBB Certified TAB Contractor Page 9 of 10 <Z7Z)MacDonald- Miller FACILITY SOLUTIONS Air Handling Unit PROJECT: Group Health AMB Pharmacy FL2 LOCATION: Tukwila WA 98168, WA PROJECT #: 7317040 DATE: 3/1/2012 CONTACT: SYSTEM /UNIT: AHU -01 / VAV -225 AREA: Unit Data Manufacturer Model Number Serial Number VAV Address Box Inlet Size K Factor Enviro -Tec CVFQ -0611 E 111222 -21 VAV -225 6" 0.60 AHU -01 / VAV -225 Supply Outlet Summary REF # 12 Tested By: Noah Walker Test Date: February 29, 2012 Term Box Test Data Max Design CFM 275 CFM Max Actual CFM 275 CFM Max Setpoint 276 Min Design CFM 100 CFM Min Actual CFM 110 CFM Min Setpoint 100 Max Diff. SP 0.3700 in. wc Min Diff. SP 0.0490 in. wc Reheat Design CFM 300 CFM Reheat Actual CFM 305 CFM VAV Delta T 17 Deg F ECM Fan Voltage 5.5 VDC Filter Size 12.75x13.75x1 inches System t Unit ' T1O Type of Reading Outlet Type. Size Design Reading Prelim Reading % Pre ' Final Reading % Final Outlet -01 T/O Flow Hood CD 10X10 300 175 58 305 102 Totals • k 300 '; 175 58 % 305 102 % * Notes AHU -01 / VAV -225 29- Feb -12 Noah Walker Min fan speed 150 CFM. Actual is 155. MacDonald-Miller NEBB Certified TAB Contractor Page 10 of 10 MacDonald-Miller FACILITY SOLUTIONS Electric Coil PROJECT: Group Health AMB Pharmacy FL2 LOCATION: Tukwila WA 98168, WA PROJECT #: 7317040 DATE: 3/1/2012 CONTACT: SYSTEM /UNIT: VAV -223 NOTES: ref # 1 Tested By: Noah Walker Test Date: February 29, 2012 Air Test Data Airflow Design Airflow Actual Air Temp Delta T 490 CFM 480 CFM 32 Deg F SYSTEM /UNIT: VAV -224 Unit Data EDH Rated KW EDH Stages Design Delta T 4.5 KW 2 29 Deg F Test Data EDH Design Volts EDH Design Amps EDH Act. Volts 1 EDH Act. Amps 1 277 Volts 16.25 Amps 280 Volts 15.10 Amps NOTES: ref # 1 Tested By: Noah Walker Test Date: February 29, 2012 Air Test Data Airflow Design Airflow Actual Air Temp Delta T 490 CFM 480 CFM 32 Deg F SYSTEM /UNIT: VAV -224 NOTES: ref # 2 Tested By: Noah Walker Test Date: February 29, 2012 Air Test Data Airflow Design Airflow Actual Air Temp Delta T 780 CFM 820 CFM 19 Deg F SYSTEM /UNIT: VAV -225 Unit Data EDH Rated KW EDH Stages Design Delta T 4.0 KW 1 16 Deg F Test Data EDH Design Volts EDH Design Amps EDH Act. Volts 1 EDH Act. Amps 1 277 Volts 14.44 Amps 282 Volts 14.00 Amps NOTES: ref # 2 Tested By: Noah Walker Test Date: February 29, 2012 Air Test Data Airflow Design Airflow Actual Air Temp Delta T 780 CFM 820 CFM 19 Deg F SYSTEM /UNIT: VAV -225 NOTES: ref # 3 Tested By: Noah Walker Test Date: February 29, 2012 Air Test Data Airflow Design Airflow Actual Air Temp Delta T 300 CFM 305 CFM 17 Deg F MacDonald- Miller NEBB Certified TAB Contractor Page 1 of 1 Unit Data EDH Rated KW EDH Stages Design Delta T 1.5 KW 1 16 Deg F Test Data EDH Design Volts EDH Design Amps EDH Act. Volts 1 EDH Act. Amps 1 277 Volts 5.4 Amps 281 Volts 5.10 Amps NOTES: ref # 3 Tested By: Noah Walker Test Date: February 29, 2012 Air Test Data Airflow Design Airflow Actual Air Temp Delta T 300 CFM 305 CFM 17 Deg F MacDonald- Miller NEBB Certified TAB Contractor Page 1 of 1 7317040 Group Health AMB Pharmacy REVIEWED FOR CODE COMPLIANCE APPROVED JAN 032012 City of Tukwila BUILDING DIVISION MANE' Location Building owner Program user Company Comments By Dataset name Calculation time TRACE® 700 version Location Latitude Longitude Time Zone Elevation Barometric pressure Air density Air specific heat Density - specific heat product Latent heat factor Enthalpy factor Summer design dry bulb Summer design wet bulb Winter design dry bulb Summer clearness number Winter clearness number Summer ground reflectance Winter ground reflectance Carbon Dioxide Level Design simulation period Cooling load methodology Heating load methodology 12501 East Marginal Way S, Tukwila, WA GEORGE GRAHAM MacDonald Miller Facility Solutions 2nd Floor NE Corner p MMFS C:1Documents and SettingslgrahamlMy DocumentslTRACE 700 ProjectslGroup Health Tukwila\GH1.TRC 08:53 AM on 11/28/2011 6.2.6.5 Seattle, Washington deg deg 47.0 122.0 8 386 29.5 0.0749 0.2444 1.0988 4,836.9 4.4953 82 66 24 0.95 0.95 0.20 0.20 400 ft in. Hg lb/cu ft BtuIIb• °F Btu/h•cfm• °F Btu•min /h•cu ft lb-min/hr-cu ft °F °F °F ppm January - December CLTD -CLF (ASHRAE TFM1 UATD Cgs er,orcevlir GTYOKVNLA DEC 2 2 2011 PERMIT CENTER ■RAGmo =Wan from MIRO M1HW System Checksums By MMFS System - 001 COOLING COIL PEAK Peaked at Time: Mo /Hr. 7 / 15 Outside Air. OADBM/B/HR: 82 / 66 / 71 Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass/Door Cond Wall Cond Partition/Door Floor Adjacent Floor Infiltration Sub Total = => Internal Loads Lights People Misc Sub Total = => Ceiling Load Ventilation Load Adj Air Trans Heat Dehumid. Ov Sizing OvlUndr Sizing Exhaust Heat Sup. Fan Heat Ret Fan Heat Duct Heat Pkup Underflr Sup Ht Pkup Supply Air Leakage Space Plenum Sens. + Lat Sens. + Lat Btu/h Btu/h Net Percent Total Of Total Btu/h ( %) 0 0 0 0 0 0 0 0 O 20,752 20,752 9 0 0 0 0 O 0 0 0 3,052 1,316 4,368 2 O 0 0 O 0 0 O 0 0 0 1,747 1,747 1 4,799 22,067 26,867 11 28,609 7,152 35,761 15 65,700 0 65,700 28 85,832 0 85,832 37 180,141 7,152 187,294 80 8,344 -8,344 0 0 O 0 19,630 8 O 0 0 O 0 O 0 0 -4,101 -4,101 -2 4,404 2 0 0 0 0 0 0 O 0 0 0 0 Grand Total => 193,285 16,775 234,094 100.00 CLG SPACE PEAK Mo /Hr.7/18 OADB: 78 Space Sensible Btu/h 0 0 0 0 0 2,671 0 0 0 428 3,100 28,609 36,500 85,832 150,941 10,874 0 0 0 Percent Of Total ( %) 0 0 0 0 0 2 0 0 0 0 2 17 22 52 92 7 0 0 0 164,915 100.00 Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass/Door Cond Wall Cond Partition/Door Floor Adjacent Floor Infiltration Sub Total =_> Internal Loads Lights People Misc Sub Total = => Ceiling Load Ventilation Load Adj Air Trans Heat OvlUndr Sizing Exhaust Heat OA Preheat Diff. RA Preheat Diff. Additional Reheat Underftr Sup Ht Pkup Supply Air Leakage Grand Total => HEATING COIL PEAK Mo/Hr. Heating Design OADB: 24 Space Peak Coil Peak Percent Space Sens Tot Sens Of Total Btu/h Btu/h (%) O 0 0.00 O 0 0.00 O - 43,972 31.35 O 0 0.00 O 0 0.00 -7,894 - 11,494 8.20 0 0 0.00 O 0 0.00 O 0 0 -6,379 -6,379 4.55 - 14,272 - 61,845 44.09 O 0 0.00 O 0 0.00 - 4,733 -4,733 3.37 -4,733 -4,733 3.37 - 13,394 0 0.00 O - 68,676 48.96 0 0 0 O 0 0.00 6,582 -4.69 O 0.00 - 11,587 8.26 O 0.00 O 0.00 O 0.00 - 32,399 - 140,258 100.00 Total Capacity ton MBh Main Clg 19.5 234.1 Aux Clg 0.0 0.0 Opt Vent 0.0 0.0 Total 19.5 234.1 COOLING COIL SELECTION Sens Cap. Coil Airflow Enter DB/WB/HR MBh cfm °F °F grit) 194.9 7,431 78.3 63.0 62.8 0.0 0 0.0 0.0 0.0 0.0 0 0.0 0.0 0.0 Leave DBIWB/HR °F °F grAb 54.5 52.1 55.2 0.0 0.0 0.0 0.0 0.0 0.0 Project Name: Dataset Name: 7317040 Group Health AMB Pharmacy GH1.TRC AREAS Gross Total Glass Floor 10,478 Part 0 Int Door 0 ExFIr 0 Roof 10,478 Wall 2,574 Ext Door 0 ft' ( %) 0 0 0 0 0 0 Series Fan - Powered VAV TEMPERATURES Cooling Heating 55.0 73.9 77.5 66.0 77.5 66.0 78.3 40.9 0.1 0.0 0.1 0.0 0.4 0.0 SADB Ra Plenum Return Ret/OA Fn MtrTD Fn BIdTD Fn Frict AIRFLOWS Cooling 7,584 7,584 7,504 7,584 679 679 126 2,275 7,630 806 0 0 0 0 Diffuser Terminal Main Fan Sec Fan Nom Vent AHU Vent Infil MinStoplRh Return Exhaust Rm Exh Auxiliary Leakage Dwn Leakage Ups Heating 7,584 7,584 2,275 7,584 1,359 1,359 126 2,275 2,401 1,485 0 0 0 0 ENGINEERING CKS Cooling Heating % OA 18.1 17.9 cfmlW 0.72 0.72 cfmlton 384.67 fWton 537.12 Btu/hrfe 22.34 -13.39 No. People 146 HEATING COIL SELECTION Capacity Coil Airflow Ent MBh cfm °F Main Htg Aux Htg Preheat Humidif Opt Vent Total -94.8 0.0 -45.5 Lvg °F 7,584 62.5 73.9 0 0.0 0.0 1,359 24.0 54.5 0.0 0 0.0 0.0 0.0 0 0.0 0.0 -140.3 TRACE® 700 v6.2.6.5 calculated at 08:53 AM on 11/28/2011 Alternative - 1 System Checksums Report Page 1 of 1 Room Checksums By MMFS 201 Entry COOLING COIL PEAK CLG SPACE PEAK Peaked at Time: Mo /Hr: 7 / 16 Mo /Hr: 7 / 16 Outside Air: OADB/WB /HR: 81 / 65 / 68 OADB: 81 Space Plenum Net Percent Space Percent Sens. + Lat. Sens. + Lat Total Of Total Sensible Of Total Btu /h Btu/h Btu /h ( %) Btu /h ( %) Envelope Loads Skylite Solar 0 0 0 0 0 0 Skylite Cond 0 0 0 0 0 0 Roof Cond 0 229 229 22 0 0 Glass Solar 0 0 0 0 0 0 Glass /Door Cond 0 0 0 0, 0 0 Wall Cond 120 49 168 16 120 17 Partition /Door 0 0 0 0 0 Floor 0 0 0 0 0 Adjacent Floor 0 0 0 0 • 0 0 Infiltration 78 78 8 46 7 Sub Total ==> 197 278 476 46' 166 24 Internal Loads Lights 268 67 334 33 268 39 People 0 0 0 0: 0 0 Misc 167 0 167 16 167 24 Sub Total = => 435 67 502 49 435 63 Ceiling Load 87 -87 0 0 87 13 Ventilation Load 0 0 70 7 0 0 Adj Air Trans Heat 0 0 0 0 0 Dehumid. Ov Sizing 0 0 Ov /Undr Sizing 0 0 0 0 Exhaust Heat -38 -38 -4 Sup. Fan Heat 19 2 Ret. Fan Heat 0 0 0 Duct Heat Pkup 0 0 0 Underflr Sup Ht Pkup 0 0 Supply Air Leakage 0 0 0 Grand Total =_> 720 219 1,027 100.00 688 Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass /Door Cond Wall Cond Partition /Door Floor Adjacent Floor Infiltration Sub Total = => Internal Loads Lights People Misc Sub Total = => Ceiling Load Ventilation Load Adj Air Trans Heat Ov /Undr Sizing 0 , Exhaust Heat OA Preheat Diff. RA Preheat Diff. Additional Reheat System Plenum Heat Underflr Sup Ht Pkup Supply Air Leakage 100.00 Grand Total ==> HEATING COIL PEAK Mo /Hr: Heating Design OADB: 24 Space Peak Coil Peak Percent Space Sens Tot Sens Of Total Btu /h Btu /h ( %) 0 0 0.00 0 0 0.00 0 -411 27.01 0 0 0.00 0 0 0.00 -368 -536 35.19 0 0 0.00 0 0 0.00 0 0 0.00 -330 -330 21.69 -698 -1,277 83.88 0 0 0.00 0 0 0.00 -245 -245 16.09 -245 -245 16.09 -125 0 0.00 0 -297 19.52 0 0 0 D 0 0.00 55 -3.61 O 0.00 -44 2.91 0 0,00 286 -18.79 O 0.00 O 0.00 -1,069 -1,523 100.00 Main CIg Aux Clg Opt Vent Total Total Capacity ton MBh 0.1 1.0 0.0 0.0 0.0 0.0 0.1 1.0 COOLING COIL SELECTION Sens Cap. Coil Airflow Enter DB/WB /HR MBh cfm °F °F gr/lb 1.0 31 78.5 62.9 62.3 0.0 0 0.0 0.0 0.0 0.0 0 0.0 0.0 0.0 Leave DBIWB /HR °F °F gr/Ib 54.5 51.6 53.0 0.0 0.0 0.0 0.0 0.0 0.0 Project Name: Dataset Name: 7317040 Group Health AMB Pharmacy GH1.TRC AREAS Gross Total Glass Floor 98 Part 0 Int Door 0 ExFlr 0 Roof 98 Wall 120 Ext Door 0 ft' ( %) O 0 O 0 0 0 TEMPERATURES Cooling Heating 55.0 101.1 77.8 66.0 77.8 66.0 78.5 39.7 0.1 0.0 0.1 0.0 0.4 0.0 SADB Ra Plenum Return Ret/OA Fn MtrTD Fn BIdTD Fn Frict AIRFLOWS Cooling 31 31 31 31 6 6 7 9 38 12 0 0 0 0 Diffuser Terminal Main Fan Sec Fan Nom Vent AHU Vent Infil MinStop /Rh Return Exhaust Rm Exh Auxiliary Leakage Dwn Leakage Ups Heating 31 31 9 31 6 6 7 9 16 12 0 0 0 0 ENGINEERING CKS % OA cfm/ft' cfm /ton ft' /ton Btu /heft' No. People Cooling 18.8 0.32 365.65 1,144.78 10.48 0 Heating 18.8 0.32 -15.54 HEATING COIL SELECTION Capacity Coil Airflow Ent MBh cfm °F Main Htg Aux Htg Preheat Humidif Opt Vent Total -1.3 0.0 -0.2 Lvg °F 31 62.5 101.1 0 0.0 0.0 6 24.0 54.5 0.0 0 0.0 0.0 0.0 0 0.0 0.0 -1.5 TRACE® 700 v6.2.6.5 calculated at 08:53 AM on 11/28/2011 Alternative - 1 System Checksums Report Page 1 of 25 Room Checksums By MMFS 202 Office COOLING COIL PEAK Peaked at Time: Mo /Hr: 7 / 15 Outside Air: OADB/WB /HR: 82 / 66 / 71 Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass /Door Cond Wall Cond Partition /Door Floor Adjacent Floor Infiltration Sub Total = => Internal Loads Lights People Misc Sub Total = => Ceiling Load Ventilation Load Adj Air Trans Heat Dehumid. Ov Sizing OvlUndr Sizing Exhaust Heat Sup. Fan Heat Ret. Fan Heat Duct Heat Pkup Underflr Sup Ht Pkup Supply Air Leakage Grand Total = => Space Plenum Sens. + Lat. Sens. + Lat Btu /h Btu /h CLG SPACE PEAK Mo /Hr: 7 / 16 OADB: 81 Net Percent Space Total Of Total Sensible Btu /h ( %) Btu /h o 0 0 0 0 O 0 0 0 0 O 241 241 11 0 O 0 0 0 0 O 0 0 0 0 133 54 187 8 144 O 0 0 0 O 0 0 0 O 0 0 0 0 118 118 5 57 251 295 546 24 200 330 83 413 18 330 450 0 450 20 250 718 0 718 31 718 1,499 83 1,581 69 1,299 96 -96 0 0 108 0 0 179 8 0 0 0 0 0 0 0 0 0 0 0 -56 -56 -2 43 2 0 0 0 0 0 0 0 0 0 0 0 1,846 226 2,294 100.00 1,607 Percent Of Total (%) Envelope Loads 0 Skylite Solar 0 Skylite Cond 0 0 0 9 0 0 0 4 12 Roof Cond Glass Solar Glass /Door Cond Wall Cond Partition /Door Floor Adjacent Floor Infiltration Sub Total = => Internal Loads 21 Lights 16 People 45 Misc 81 Sub Total = => 7 Ceiling Load 0 Ventilation Load 0 Adj Air Trans Heat Ov /Undr Sizing 0 Exhaust Heat OA Preheat Diff. RA Preheat Diff. Additional Reheat System Plenum Heat Underflr Sup Ht Pkup Supply Air Leakage 100.00 Grand Total = => HEATING COIL PEAK Mo /Hr: Heating Design OADB: 24 Space Peak Coil Peak Percent Space Sens Tot Sens Of Total Btu /h Btu /h (%) 0 0 0.00 0 0 0.00 0 -508 21.90 O 0 0.00 0 0 0.00 -442 -643 27.74 0 0 0.00 O 0 0.00 0 0 0.00 - 408 -408 17.59 - 849 -1,559 67.23 0 0 0.00 O 0 0.00 - 303 -303 13.05 - 303 -303 13.05 -155 0 0.00 0 -620 26.73 0 0 0 O 0 0.00 90 -3.89 0 0.00 -122 5.28 0 0.00 195 -8.39 0 0.00 0 0.00 -1,307 -2,318 100.00 Main Clg Aux Clg Opt Vent Total Total Capacity ton MBh 0.2 2.3 0.0 0.0 0.0 0.0 0.2 2.3 COOLING COIL SELECTION Sens Cap. Coil Airflow Enter DBIWB /HR MBh cfm °F °F gr/lb 2.0 72 78.3 62.9 62.7 0.0 0 0.0 0.0 0.0 0.0 0 0.0 0.0 0.0 Leave DBIWB /HR °F °F gr/Ib 54.5 52.0 54.7 0.0 0.0 0.0 0.0 0.0 0.0 Project Name: Dataset Name: 7317040 Group Health AMB Pharmacy GH1.TRC AREAS Gross Total Glass ft' (%) Floor 121 Part 0 Int Door 0 ExFlr 0 Roof 121 Wall 144 Ext Door 0 O 0 O 0 O 0 TEMPERATURES Cooling Heating 55.0 86.3 77.5 66.0 77.5 66.0 78.3 42.5 0.1 0.0 0.1 0.0 0.4 0.0 SADB Ra Plenum Return Ret/OA Fn MtrTD Fn BIdTD Fn Frict AIRFLOWS Cooling 73 73 73 73 12 12 8 22 81 20 0 0 0 0 Diffuser Terminal Main Fan Sec Fan Nom Vent AHU Vent Infil MinStop/Rh Return Exhaust Rm Exh Auxiliary Leakage Dwn Leakage Ups Heating 73 73 22 73 12 12 8 22 30 20 0 0 0 0 ENGINEERING CKS io OA cfmlft cfm/ton ft' /ton Btu/hrfe No. People Cooling 16.8 0.60 382.62 633.07 18.96 1 Heating 16.8 0.60 -19.16 HEATING COIL SELECTION Capacity Coil Airflow Ent MBh cfm °F Main Htg Aux Htg Preheat Humidif Opt Vent Total -1.9 0.0 Lvg °F 73 62.5 86.3 0 0.0 0.0 -0.4 12 24.0 54.5 0.0 0 0.0 0.0 0.0 0 0.0 0.0 -2.3 TRACE® 700 v6.2.6.5 calculated at 08:53 AM on 11/28/2011 Alternative - 1 System Checksums Report Page 2 of 25 Room Checksums By MMFS 203 Conference COOLING COIL PEAK CLG SPACE PEAK Peaked at Time: Outside Air: Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass /Door Cond Wall Cond Partition /Door Floor Adjacent Floor Infiltration Sub Total =_> Internal Loads Lights People Misc Sub Total = => Ceiling Load Ventilation Load Adj Air Trans Heat Dehumid. Ov Sizing Ov /Undr Sizing Exhaust Heat Sup. Fan Heat Ret. Fan Heat Duct Heat Pkup Underflr Sup Ht Pkup Supply Air Leakage Grand Total = => Space Sens. + Lat. Btu /h Mo /Hr: 7 / 15 OADB/WB /HR: 82 / 66 / 71 Mo /Hr: 7 / 16 OADB: 81 Plenum Net Percent Space Percent Sens. + Lat Total Of Total Sensible Of Total Btu /h Btu /h ( %) Btu /h (Vol o o 0 0 0 0 o o 0 0 0 0 o 241 241 4 0 0 o o 0 0 0 0 o 0 0 0 0 0 133 54 187 3 144 4 O 0 0 0 0 0 0 0 0 0 0 D 0 0 0 0 118 118 2 57 1 251 295 546 9 200 5 330 83 413 7 330 8 2,700 0 2,700 44 1,500 37 1,918 0 1,918 31 1,918 47 4,949 83 5,031 82 3,749 92 96 -96 0 0 108 3 O 0 544 9 0 0 O 0 0 0 0 0 0 0 0 0 0 0 -125 -125 -2 109 2 O 0 0 0 0 0 0 0 O 0 0 5,296 157 6,106 100.00 4,057 100.00 Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass /Door Cond Wall Cond Partition/Door Floor Adjacent Floor Infiltration Sub Total = => Internal Loads Lights People Misc Sub Total = => Ceiling Load Ventilation Load Adj Air Trans Heat Ov /Undr Sizing Exhaust Heat OA Preheat Diff. RA Preheat Diff. Additional Reheat System Plenum Heat Underflr Sup Ht Pkup Supply Air Leakage Grand Total = => HEATING COIL PEAK Mo /Hr: Heating Design OADB: 24 Space Peak Coil Peak Percent Space Sens Tot Sens Of Total Btu /h Btu /h ( %) O 0 0.00 O 0 0.00 0 -508 12.47 0 0 0.00 0 0 0.00 -442 -643 15.79 O 0 0.00 0 0 0.00 0 0 0.00 - 408 -408 10.01 -849 -1,559 38.27 0 0 0.00 0 0 0.00 -303 -303 7.43 -303 -303 7.43 -155 0 0.00 O -1,883 46.25 0 0 0 0 0 0.00 201 -4.93 0 0.00 -229 5.63 0 0.00 -300 7.36 0 0.00 0 0.00 -1,307 -4,072 100.00 Main Clg Aux Clg Opt Vent Total Total Capacity ton MBh 0.5 6.1 0.0 0.0 0.0 0.0 0.5 6.1 COOLING COIL SELECTION Sens Cap. Coil Airflow Enter DB/WB /HR MBh cfm °F °F gr/lb 4.6 184 78.4 63.1 63.0 0.0 0 0.0 0.0 0.0 0.0 0 0.0 0.0 0.0 Leave DB/WB /HR °F °F gr/lb 54.5 51.6 53.1 0.0 0.0 0.0 0.0 0.0 0.0 Project Name: Dataset Name: 7317040 Group Health AMB Pharmacy GH1.TRC AREAS Gross Total Glass Floor 121 Part 0 Int Door 0 ExFIr 0 Roof 121 Wall 144 Ext Door 0 ft' ( %) 0 0 0 0 0 0 TEMPERATURES Cooling Heating 55.0 76.4 77.5 66.0 77.5 66.0 78.4 37.7 0.1 0.0 0.1 0.0 0.4 0.0 SADB Ra Plenum Return Ret/OA Fn MtrTD Fn BIdTD Fn Frict AIRFLOWS Cooling 185 185 185 185 37 37 8 55 193 45 0 0 0 0 Diffuser Terminal Main Fan Sec Fan Nom Vent AHU Vent Infil MinStop /Rh Return Exhaust Rm Exh Auxiliary Leakage Dwn Leakage Ups Heating 185 185 55 185 37 37 8 55 63 45 0 0 0 0 ENGINEERING CKS % OA cfm/ft• cfm/ton ft' /ton Btu /hrft' No. People Cooling 20.2 1.53 362.83 237.80 50.46 6 Heating 20.2 1.53 -33.65 HEATING COIL SELECTION Capacity Coil Airflow Ent MBh cfm °F Main Htg Aux Htg Preheat Humidif Opt Vent Total -2.8 0.0 -1.3 Lvg °F 185 62.5 76.4 0 0.0 0.0 37 24.0 54.5 0.0 0 0.0 0.0 0.0 0 0.0 0.0 -4.1 TRACE® 700 v6.2.6.5 calculated at 08:53 AM on 11/28/2011 Alternative - 1 System Checksums Report Page 3 of 25 Room Checksums By MMFS 204 Conference COOLING COIL PEAK Peaked at Time: Outside Air: Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass /Door Cond Wall Cond Partition /Door Floor Adjacent Floor Infiltration Sub Total = => Internal Loads Lights People Misc Sub Total = => Ceiling Load Ventilation Load Adj Air Trans Heat Dehumid. Ov Sizing Ov /Undr Sizing Exhaust Heat Sup. Fan Heat Ret. Fan Heat Duct Heat Pkup Underfir Sup Ht Pkup Supply Air Leakage Grand Total = => CLG SPACE PEAK Mo /Hr: 7 / 15 Mo /Hr: 7 / 16 OADB/WB /HR: 82 / 66 / 71 OADB 81 Space Plenum Sens. + Lat. Sens. + Lat Btu /h Btu /h Net Percent Space Total Of Total Sensible Btu /h ( %) Btu /h o 0 0 0 0 o 0 0 0 o O 241 241 4 0 o o 0 0 0 o o 0 0 0 133 54 187 3 144 O 0 0 0 o 0 0 0 o o 0 0 0 118 118 2 57 251 295 546 9 200 Percent Of Total ( %) Envelope Loads 0 Skylite Solar 0 Skylite Cond O Roof Cond 0 Glass Solar O Glass /Door Cond 4 Wall Cond 0 Partition/Door 0 Floor O Adjacent Floor 1 Infiltration 5 . Sub Total = => 330 83 413 7 330 8 2.700 0 2,700 44 1,500 37 1.918 0 1,918 31 1,918 47 4,949 83 5,031 82 3,749 92 96 -96 0 0 108 3 0 0 544 9 0 0 0 0 0 0 0 0 0 O 0 0 0 0 -125 -125 -2 109 2 O 0 0 O 0 0 0 0 0 0 0 Internal Loads Lights People Misc Sub Total = => Ceiling Load Ventilation Load Adj Air Trans Heat Ov /Undr Sizing Exhaust Heat OA Preheat Diff. RA Preheat Diff. Additional Reheat System Plenum Heat Underfir Sup Ht Pkup Supply Air Leakage 5.296 157 6.106 100.00 4,057 100.00 Grand Total = => HEATING COIL PEAK Mo /Hr: Heating Design OADB: 24 Space Peak Coil Peak Percent Space Sens Tot Sens Of Total Btu /h Btu /h ( %) 0 0 0.00 0 0 0.00 0 -508 12.47 O 0 0.00 0 0 0.00 - 442 -643 15.79 O 0 0.00 O 0 0.00 0 0 0.00 - 408 -408 10.01 -849 -1,559 38.27 O 0 0.00 O 0 0.00 - 303 -303 7.43 -303 -303 7.43 -155 0 0.00 O -1,883 46.25 O 0 0 0 0 0.00 201 -4.93 0 0.00 -229 5.63 O 0.00 -300 7.36 O 0.00 0 0.00 -1,307 -4,072 100.00 Main Clg Aux Clg Opt Vent Total Total Capacity ton MBh 0.5 6.1 0.0 0.0 0.0 0.0 0.5 6.1 COOLING COIL SELECTION Sens Cap. Coil Airflow Enter DBIWB /HR MBh cfm °F °F or/lb 4.6 0.0 184 78.4 63.1 0 0.0 0.0 63.0 Leave DBIWB /HR °F °F gr/lb 54.5 51.6 53.1 0.0 0.0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Project Name: Dataset Name: 7317040 Group Health AMB Pharmacy GH1.TRC AREAS Gross Total Glass Floor 121 Part 0 Int Door 0 ExFlr 0 Roof 121 Wall 144 Ext Door 0 ft' ( %) O 0 O 0 O 0 TEMPERATURES Cooling Heating 55.0 76.4 77.5 66.0 77.5 66.0 78.4 37.7 0.1 0.0 0.1 0.0 0.4 0.0 SADB Ra Plenum Return Ret/OA Fn MtrTD Fn BIdTD Fn Frict AIRFLOWS Cooling 185 185 185 185 37 37 8 55 193 45 0 0 0 0 Diffuser Terminal Main Fan Sec Fan Nom Vent AHU Vent Infil MinStoplRh Return Exhaust Rm Exh Auxiliary Leakage Dwn Leakage Ups Heating 185 185 55 185 37 37 8 55 63 45 0 0 0 0 ENGINEERING CKS % OA cfm/ft' cfm/ton ft'/ton Btulhrff' No. People Cooling 20.2 1.53 362.83 237.80 50.46 6 Heating 20.2 1.53 -33.65 HEATING COIL SELECTION Capacity Coil Airflow Ent MBh cfm °F Main Htg Aux Htg Preheat Humidif Opt Vent Total -2.8 0.0 Lvg °F 185 62.5 76.4 0 0.0 0.0 -1.3 37 24.0 54.5 0.0 0 0.0 0.0 0.0 0 0.0 0.0 -4.1 TRACE® 700 v6.2.6.5 calculated at 08:53 AM on 11/28/2011 Alternative - 1 System Checksums Report Page 4 of 25 Room Checksums By MMFS 205 Workstations COOLING COIL PEAK Peaked at Time: Outside Air: Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass /Door Cond Wall Cond Partition /Door Floor Adjacent Floor Infiltration Sub Total = => Internal Loads Lights People Misc Sub Total = => Ceiling Load Ventilation Load Adj Air Trans Heat Dehumid. Ov Sizing OvlUndr Sizing Exhaust Heat Sup. Fan Heat Ret. Fan Heat Duct Heat Pkup Underflr Sup Ht Pkup Supply Air Leakage Grand Total = => Space Sens. + Lat. Btu /h Mo /Hr: 7 / 15 OADB/ B/HR: 82 / 66 / 71 CLG SPACE PEAK Mo /Hr: 7 / 16 OADB: 81 Plenum Net Percent Space Percent Sens. + Lat Total Of Total Sensible Of Total Btu/h Btu /h (%) Btu/h (i ) 0 0 0 0 0 0 0 0 0 0 0 0 0 824 824 7 0 0 0 0 0 0 0 0 0 0 0 0 0 0 553 226 780 6 598 7 0 0 0 0 0 0 0 0 0 0 O 0 0 0 0 0 357 357 3 194 2 910 1,050 1,960 16 792 9 1,130 283 1,413 11 1,130 3,600 0 3,600 29 2,000 4,802 0 4,802 38 4,802 9,532 283 9,815 78 7,932 Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass /Door Cond Wall Cond Partition /Door Floor Adjacent Floor Infiltration Sub Total = => Internal Loads 12 Lights 22 People 53 Misc 87 Sub Total = => 330 -330 0 0 369 4 O 0 838 7 0 0 O 0 0 0 0 0 0 O 0 0 0 0 -255 -255 -2 243 2 0 0 0 0 0 0 0 0 0 0 0 Ceiling Load Ventilation Load Adj Air Trans Heat Ov /Undr Sizing Exhaust Heat OA Preheat Diff. RA Preheat Diff. Additional Reheat System Plenum Heat Underflr Sup Ht Pkup Supply Air Leakage 10,772 748 12,601 100.00 9,094 100.00 Grand Total ==> HEATING COIL PEAK Mo /Hr: Heating Design OADB: 24 Space Peak Space Sens Btu /h 0 0 0 0 0 -1,840 0 0 0 -1,395 -3,235 0 0 -1,035 -1,035 -529 0 0 0 -4,799 Coil Peak Percent Tot Sens Of Total Btu /h (%) 0 0.00 0 0.00 -1,737 16.75 O 0.00 O 0.00 -2,679 25.83 0 0.00 0 0.00 O 0.00 -1,395 13.45 -5,812 56.03 0 0.00 0 0.00 -1,035 9.98 -1,035 9.98 O 0.00 -3,277 31.59 0 0 0 0.00 410 -3.95 0 0.00 -750 7.23 D 0.00 91 -0.88 D 0.00 D 0.00 - 10,373 100.00 Total Capacity ton MBh Main CIg 1.1 Aux Clg 0.0 Opt Vent 0.0 Total 1.1 COOLING COIL SELECTION Sens Cap. Coil Airflow Enter DB/WBIHR MBh cfm °F °F gr/lb 12.6 10.5 411 78.2 62.9 62.6 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0 0.0 0.0 0.0 12.6 Leave DB/WBIHR °F °F gr/lb 54.5 52.3 56.0 0.0 0.0 0.0 0.0 0.0 0.0 Project Name: Dataset Name: 7317040 Group Health AMB Pharmacy GH1.TRC AREAS Gross Total Glass Floor 414 Part 0 Int Door 0 ExFlr 0 Roof 414 Wall 600 Ext Door 0 ft= (OA) 0 0 0 0 0 0 TEMPERATURES Cooling Heating 55.0 80.6 77.5 66.0 77.5 66.0 78.2 44.1 0.1 0.0 0.1 0.0 0.4 0.0 SADB Ra Plenum Return Ret/OA Fn MtrTD Fn BIdTD Fn Frict AIRFLOWS Cooling 414 414 414 414 65 65 28 124 441 92 0 0 0 0 Diffuser Terminal Main Fan Sec Fan Nom Vent AHU Vent Intl MinStop!Rh Return Exhaust Rm Exh Auxiliary Leakage Dwn Leakage Ups Heating 414 414 124 414 65 65 28 124 152 92 0 0 0 0 ENGINEERING CKS OA cfmlfe cfm/ton W/ton Btu/hrft' No. People Cooling 15.7 1.00 394.05 394.24 30.44 8 Heating 15.7 1.00 -25.06 HEATING COIL SELECTION Capacity Coil Airflow Ent MBh cfm °F Main Htg Aux Htg Preheat Humidif Opt Vent Total Lvg °F -8.2 414 62.5 80.6 0.0 0 0.0 0.0 -2.2 65 24.0 54.5 0.0 0 0.0 0.0 0.0 0 0.0 0.0 -10.4 TRACE® 700 v6.2.6.5 calculated at 08:53 AM on 11/28/2011 Alternative - 1 System Checksums Report Page 5 of 25 Room Checksums By MMFS 206 Office COOLING COIL PEAK Peaked at Time Outside Air: Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass /Door Cond Wall Cond Partition/Door Floor Adjacent Floor Infiltration Sub Total =_> Internal Loads Lights People Misc Sub Total = => Ceiling Load Ventilation Load Adj Air Trans Heat Dehumid. Ov Sizing Ov /Undr Sizing Exhaust Heat Sup. Fan Heat Rat. Fan Heat Duct Heat Pkup Underflr Sup Ht Pkup Supply Air Leakage Grand Total =_> Mo /Hr: 7 / 15 OADB/WB /HR: 82 / 66 / 71 Space Plenum Sens. + Lat. Sens. + Lat Btu /h Btu /h Net Total Btu /h Percent Of Total ( %) O 0 0 0 O 0 0 0 O 153 153 8 O 0 0 0 O o 0 0 111 45 156 8 O 0 0 0 0 0 0 0 0 0 75 75 4 186 198 384 20 210 53 263 14 450 0 450 24 643 0 643 34 1,304 53 1,356 72 61 -61 0 0 O 0 141 7 O 0 0 0 0 0 0 0 -41 -41 -2 35 2 0 0 0 0 0 0 o o 0 0 0 1,551 149 1,876 100.00 CLG SPACE PEAK Mo /Hr: 7 / 16 OADB: 81 Space Percent Sensible Of Total Btu /h ( %) Envelope Loads O 0 Skylite Solar O 0 Skylite Cond O 0 Roof Cond 0 0 Glass Solar 0 0 ' Glass /Door Cond 120 9 : Wall Cond O 0. Partition /Door O 0 Floor 0 0 Adjacent Floor 36 3 Infiltration 156 12 Sub Total = => Internal Loads 210 16 Lights 250 19 People 643 48 Misc 1,104 83 Sub Total ==> 69 5 Ceiling Load O 0 Ventilation Load 0 0 Adj Air Trans Heat Ov /Undr Sizing 0 0 ' Exhaust Heat OA Preheat Diff. RA Preheat Diff. Additional Reheat System Plenum Heat Underflr Sup Ht Pkup Supply Air Leakage 1,328 100.00 Grand Total =_> HEATING COIL PEAK Mo /Hr: Heating Design OADB: 24 Space Peak Coil Peak Percent Space Sens Tot Sens Of Total Btu /h Btu /h (%) 0 0 0.00 0 0 0.00 0 -323 18.60 0 0 0.00 0 0 0.00 -368 -536 30.84 0 0 0.00 0 0 0.00 O 0 0.00 -259 -259 14.93 -627 -1,118 64.38 O 0 0.00 0 0 0.00 -193 -193 11.08 -193 -193 11.08 -98 0 0.00 0 -486 27.99 O 0 0 0 0 0.00 65 -3.76 0 0.00 -108 6.19 0 0.00 102 -5.87 0 0.00 0 0.00 -918 -1,737 100.00 Main Clg Aux Clg Opt Vent Total Total Capacity ton MBh 0.2 1.9 0.0 0.0 0.0 0.0 0.2 1.9 COOLING COIL SELECTION Sens Cap. Coil Airflow Enter DB/WB/HR MBh cfm °F °F grub 1.6 0.0 0.0 60 78.2 62.9 62.6 0 0.0 0.0 0.0 0 0.0 0.0 0.0 Leave DB/WB /HR °F °F gr/lb 54.5 52.1 0.0 0.0 0.0 0.0 55.0 0.0 0.0 Project Name Dataset Name: 7317040 Group Health AMB Pharmacy GH1.TRC AREAS Gross Total Glass ft' (%) Floor 77 Part 0 Int Door 0 ExFlr 0 Roof 77 Wall 120 Ext Door 0 0 0 0 0 0 0 TEMPERATURES Cooling Heating 55.0 83.8 77.5 66.0 77.5 66.0 78.2 43.7 0.1 0.0 0.1 0.0 0.4 0.0 SADB Ra Plenum Return Ret/OA Fn MtrTD Fn BIdTD Fn Frict AIRFLOWS Cooling 60 60 60 60 10 10 5 18 66 15 0 0 0 0 Diffuser Terminal Main Fan Sec Fan Nom Vent AHU Vent Infil MinStoplRh Return Exhaust Rm Exh Auxiliary Leakage Dwn Leakage Ups Heating 60 60 18 60 10 10 5 18 23 15 0 0 0 0 ENGINEERING CKS OA cfm/fe cfm/ton ft' /ton Btu/hi-ft' No. People Cooling 15.9 0.78 386.60 492.66 24.36 1 Heating 15.9 0.78 -22.56 HEATING COIL SELECTION Capacity Coil Airflow Ent MBh cfm °F Main Htg Aux Htg Preheat Humidif Opt Vent Total -1.4 0.0 Lvg °F 60 62.5 83.8 0 0.0 0.0 -0.3 10 24.0 54.5 0.0 0 0.0 0.0 0.0 0 0.0 0.0 -1.7 TRACE® 700 v6.2.6.5 calculated at 08:53 AM on 11/28/2011 Alternative - 1 System Checksums Report Page 6 of 25 Room Checksums By MMFS 207 Office COOLING COIL PEAK Peaked at Time: Mo /Hr: 7 / 15 Outside Air: OADB/WB /HR: 82 / 66 / 71 Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass /Door Cond Wall Cond Partition /Door Floor Adjacent Floor Infiltration Sub Total =_> Internal Loads Lights People Misc Sub Total = => Ceiling Load Ventilation Load Adj Air Trans Heat Dehumid. Ov Sizing OvlUndr Sizing Exhaust Heat Sup. Fan Heat Ret. Fan Heat Duct Heat Pkup Underflr Sup Ht Pkup Supply Air Leakage Grand Total = => Space Plenum Sens. + Lat. Sens. + Lat Btu /h Btu /h Net Percent Total Of Total Btu /h ( %) O 0 0 0 0 0 0 0 0 133 133 8 O 0 0 0 0 0 0 0 100 41 140 8 0 0 0 O 0 0 0 0 0 0 65 65 4 165 174 339 19 183 46 229 450 0 450 626 0 626 1,259 46 1,305 53 -53 0 0 0 132 0 0 0 0 0 -37 -37 34 0 0 0 0 0 0 0 CLG SPACE PEAK Mo /Hr: 7 116 OADB: 81 Space Sensible Btu /h Percent Of Total ( %) Envelope Loads 0 0 Skylite Solar 0 0 Skylite Cond 0 0 Roof Cond 0 0 Glass Solar 0 0 Glass /Door Cond 108 9 Wall Cond 0 0 Partition /Door 0 0 Floor 0 0 Adjacent Floor 31 2 Infiltration 139 11 Sub Total = => 13 183 25 250 35 626 74 1,059 Internal Loads 15 Lights 20 People 50 Misc 84 Sub Total = => 0 60 5 , Ceiling Load 7 . 0 0 : Ventilation Load 0 0 0 Adj Air Trans Heat 0 Ov /Undr Sizing 0 0 0 Exhaust Heat -2 : OA Preheat Diff. 2 RA Preheat Diff. 0 Additional Reheat 0 System Plenum Heat 0 Underflr Sup Ht Pkup 0 Supply Air Leakage 1,477 129 1,772 100.00 1,258 100.00 Grand Total = => HEATING COIL PEAK Mo /Hr: Heating Design OADB: 24 Space Peak Coil Peak Percent Space Sens Tot Sens Of Total Btu /h Btu /h ( %) 0 0 0.00 0 0 0.00 0 -281 17.76 0 0 0.00 0 0 0.00 -331 -482 30.47 0 0 0.00 O 0 0.00 O 0 0.00 -226 -226 14.26 -557 -989 62.50 0 0 0.00 0 0 0.00 -168 -168 10.58 -168 -168 10.58 -86 0 0.00 0 -456 28.80 0 0 0 O 0 0.00 60 -3.78 0 0.00 -103 6.51 0 0.00 73 -4.62 0 0.00 0 0.00 -810 -1,583 100.00 Main Clg Aux Clg Opt Vent Total Total Capacity ton MBh 0.2 1.8 0.0 0.0 0.0 0.0 0.2 1.8 COOLING COIL SELECTION Sens Cap. Coil Airflow Enter DB/WB/HR MBh cfm °F °F grub 1.5 57 78.2 62.9 62.6 0.0 0 0.0 0.0 0.0 0.0 0 0.0 0.0 0.0 Leave DB/WB /HR °F °F grub 54.5 52.1 55.2 0.0 0.0 0.0 0.0 0.0 0.0 Project Name: Dataset Name: 7317040 Group Health AMB Pharmacy GH1.TRC AREAS Gross Total Glass Floor 67 Part 0 Int Door 0 ExFlr 0 Roof 67 Wall 108 Ext Door 0 ft' ( %) 0 0 0 0 0 0 TEMPERATURES Cooling Heating 55.0 82.9 77.5 66.0 77.5 66.0 78.2 43.9 0.1 0.0 0.1 0.0 0.4 0.0 SADB Ra Plenum Return Ret/OA Fn MtrTD Fn BIdTD Fn Frict AIRFLOWS Cooling 57 57 57 57 9 9 4 17 62 13 0 0 0 0 Diffuser Terminal Main Fan Sec Fan Nom Vent AHU Vent Infil MinStoplRh Return Exhaust Rm Exh Auxiliary Leakage Dwn Leakage Ups Heating 57 57 17 57 9 9 4 17 22 13 0 0 0 0 ENGINEERING CKS % OA cfm/ft cfm/ton fY /ton Btu/hrf' No. People Cooling 15.8 0.85 387.64 453.72 26.45 1 Heating 15.8 0.85 -23.62 HEATING COIL SELECTION Capacity Coil Airflow Ent MBh cfm °F Main Htg Aux Htg Preheat Humidif Opt Vent Total -1.3 0.0 -0.3 Lvg °F 57 62.5 82.9 0 0.0 0.0 9 24.0 54.5 0.0 0 0.0 0.0 0.0 0 0.0 0.0 -1.6 TRACE® 700 v6.2.6.5 calculated at 08:53 AM on 11/28/2011 Alternative - 1 System Checksums Report Page 7 of 25 Room Checksums By MMFS 208 Work Area COOLING COIL PEAK CLG SPACE PEAK Peaked at Time: Outside Air: Mo /Hr: 7 / 15 OADBANB/HR: 82 / 66 / 71 Mo /Hr: 7 / 16 OADB: 81 HEATING COIL PEAK Mo /Hr Heating Design OADB: 24 Space Plenum Net Percent Space Percent Space Peak Coil Peak Percent Sens. + LaL Sens. + Lat Total Of Total Sensible Of Total • Space Sens Tot Sens Of Total Btu /h Btu /h Btu /h ( %) Btu /h (%) Btu /h Btu /h Envelope Loads Envelope Loads Skylite Solar 0 0 0 0 0 0 Skylite Solar 0 0 0.00 Skylite Cond 0 0 0 0 0 0 Skylite Cond 0 0 0.00 Roof Cond 0 193 193 9 0 0 Roof Cond 0 -407 19.89 Glass Solar 0 0 0 0 0 0 Glass Solar 0 0 0.00 Glass /Door Cond 0 0 0 0 0 0 Glass /Door Cond 0 0 0.00 Wall Cond 133 54 187 9 144 10 Wall Cond - 442 -643 31,42 Partition /Door 0 0 0 0 0 Partition /Door 0 0 0.00 Floor 0 0 0 0 0 Floor 0 0 0.00 Adjacent Floor 0 0 0 0 0 0 Adjacent Floor 0 0 0.00 Infiltration 94 94 5 45 3 Infiltration -327 -327 15.97 Sub Total =_> 227 247 475 23 189 13 Sub Total =_> -768 -1,377 67.28 Internal Loads Internal Loads Lights 265 66 331 16 265 18 Lights 0 0 0.00 People 450 0 450 22 250 17 People 0 0 0.00 Misc 677 0 677 33 677 46 Misc -243 -243 11.85 Sub Total = => 1.392 66 1,459 70 1,192 81 Sub Total = => -243 -243 11.85 Ceiling Load 77 -77 0 0 86 6 Ceiling Load Ventilation Load 0 0 158 8 0 0 Ventilation Load Adj Air Trans Heat 0 0 o 0 0 Adj Air Trans Heat Dehumid. Ov Sizing 0 0 Ov /Undr Sizing Ov /Undr Sizing 0 0 0 0 0 Exhaust Heat Exhaust Heat -48 -48 -2 OA Preheat Diff. Sup. Fan Heat 39 2 : RA Preheat Diff. Rat. Fan Heat 0 0 0 Additional Reheat Duct Heat Pkup 0 0 0 System Plenum Heat Underflr Sup Ht Pkup 0 0 Underfir Sup Ht Pkup Supply Air Leakage 0 0 0 Supply Air Leakage Grand Total = => 1,697 189 2,083 100.00 1,468 100.00 Grand Total =_> -124 0 0.00 0 -547 26.72 0 0 0 0 0 0.00 77 -3.74 O 0.00 -117 5.69 O 0.00 160 -7.81 O 0.00 O 0.00 -1,135 -2,047 100.00 COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR Leave DBIWB /HR ton MBh MBh cfm °F °F grill) °F °F gr/Ib Main Clg 0.2 2.1 1.8 66 78.3 62.9 62.6 54.5 52.0 54.8 Aux Clg 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Opt Vent 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Total 0.2 2.1 Project Name: Dataset Name: 7317040 Group Health AMB Pharmacy GH1.TRC AREAS Gross Total Glass ft' (%) Floor 97 Part 0 Int Door 0 ExFlr 0 Roof 97 0 0 Wall 144 0 0 Ext Door 0 0 0 TEMPERATURES Cooling Heating 55.0 85.5 77.5 66.0 77.5 66.0 78.3 43.3 0.1 0.0 0.1 0.0 0.4 0.0 SADB Ra Plenum Return Ret/OA Fn MtrTD Fn BIdTD Fn Frict AIRFLOWS Cooling Heating 67 67 67 67 67 20 67 67 11 11 11 11 6 6 20 20 73 27 17 17 O 0 0 0 O 0 0 0 Diffuser Terminal Main Fan Sec Fan Nom Vent AHU Vent Intl! MinStoplRh Return Exhaust Rm Exh Auxiliary Leakage Dwn Leakage Ups ENGINEERING CKS Cooling Heating 16.2 16.2 0.69 0.69 384.83 558.88 21.47 -21.10 1 OA cfmlft cfm/ton ft' /ton Btu/hr -W No. People HEATING COIL SELECTION Capacity Coil Airflow Ent Lvg MBh cfm °F °F Main Htg -1.7 67 62.5 85.5 Aux Htg 0.0 0 0.0 0.0 Preheat -0.4 11 24.0 54.5 Humidif 0.0 0 0.0 0.0 Opt Vent 0.0 0 0.0 0.0 Total -2.1 TRACE® 700 v6.2.6.5 calculated at 08:53 AM on 11/28/2011 Alternative - 1 System Checksums Report Page 8 of 25 Room Checksums By MMFS 209 Office COOLING COIL PEAK Peaked at Time: Mo /Hr: 7 / 13 Outside Air: OADB/WB /HR: 80 / 65 / 72 Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass /Door Cond Wall Cond Partition /Door Floor Adjacent Floor Infiltration Sub Total = => Internal Loads Lights People Misc Sub Total ==> Ceiling Load Ventilation Load Adj Air Trans Heat Dehumid. Ov Sizing Ov /Undr Sizing Exhaust Heat Sup. Fan Heat Ret Fan Heat Duct Heat Pkup Underflr Sup Ht Pkup Supply Air Leakage Grand Total = => CLG SPACE PEAK Mo /Hr: 7 / 12 OADB: 78 Space Plenum Net Percent Space Sens. + Lat. Sens. + Lat Total Of Total Sensible Btu /h Btu /h Btu /h ( %) Btu /h O 0 0 0 0 0 0 0 0 0 0 128 128 5 0 0 0 0 0 0 0 0 0 0 0 435 202 637 26 476 0 0 0 0 0 0 0 0 O 0 0 0 0 88 88 4 20 523 330 853 34 495 Percent Of Total ( %) Envelope Loads 0 Skylite Solar 0 Skylite Cond 0 0 0 27. 0 0 0 1 28 273 68 341 14 273 16 450 0 450 18 250 14 683 0 683 28 683 39 1.406 68 1,474 59 1,206 69 60 -60 0 0 52 3 0 0 145 6 0 0 0 0 0' 0 0 0 0 D 0 0 0 0 -37 -37 -1 47 2 0 0 0 0 0 0 0 0 0 0 0 1,989 301 2,481 100.00 1,753 100.00 Roof Cond Glass Solar Glass /Door Cond Wall Cond Partition /Door Floor Adjacent Floor Infiltration Sub Total = => Internal Loads Lights People Misc Sub Total =_> Ceiling Load Ventilation Load Adj Air Trans Heat OvlUndr Sizing Exhaust Heat OA Preheat Diff. RA Preheat Diff. Additional Reheat System Plenum Heat Underflr Sup Ht Pkup Supply Air Leakage Grand Total = => HEATING COIL PEAK Mo /Hr: Heating Design OADB: 24 Space Peak Coil Peak Percent Space Sens Tot Sens Of Total Btu /h Btu /h ( %) 0 0 0.00 0 0 0.00 0 -420 16.83 O 0 0.00 0 0 0.00 -754 - 1,099 44.05 0 0 0.00 0 0 0.00 0 0 0.00 -337 -337 13.51 -1,091 -1,855 74.40 0 0 0.00 0 0 0.00 -250 -250 10.03 -250 -250 10.03 -128 0 0.00 O -556 22.30 0 0 0 O 0 0.00 78 -3.14 0 0.00 -164 6.56 0 0.00 253 -10.14 0 0.00 0 0.00 -1,469 -2,494 100.00 Main Clg Aux Clg Opt Vent Total Total Capacity ton MBh 0.2 2.5 0.0 0.0 0.0 0.0 0.2 2.5 COOLING COIL SELECTION Sens Cap. Coil Airflow Enter DB/WB /HR MBh cfm °F °F gr/lb 2.1 79 77.3 62.6 0.0 0 0.0 0.0 62.6 0.0 0.0 0 0.0 0.0 0.0 Leave DB/WB /HR °F °F gr/lb 54.5 51.7 0.0 0.0 0.0 0.0 53.5 0.0 0.0 Project Name: Dataset Name: 7317040 Group Health AMB Pharmacy GH1.TRC AREAS Gross Total Glass Floor 100 Part 0 Int Door 0 ExFIr 0 Roof 100 Wall 246 Ext Door 0 n' ( %) O 0 O 0 0 0 TEMPERATURES Cooling Heating 55.0 86.8 76.9 66.0 76.9 66.0 77.3 46.7 0.1 0.0 0.1 0.0 0.4 0.0 SADB Ra Plenum Return Ret/OA Fn MtrTD Fn BIdTD Fn Frict AIRFLOWS Cooling 80 80 80 80 11 11 7 24 86 18 0 0 0 0 Diffuser Terminal Main Fan Sec Fan Nom Vent AHU Vent Infil MinStop /Rh Return Exhaust Rm Exh Auxiliary Leakage Own Leakage Ups Heating 80 80 24 80 11 11 7 24 31 18 0 0 0 0 ENGINEERING CKS % OA cfm /ft` cfm /ton ft' /ton Btulhrft' No. People Cooling 13.8 0.80 385.80 483.60 24.81 1 Heating 13.8 0.80 -24.94 HEATING COIL SELECTION Capacity Coil Airflow Ent MBh cfm °F Main Htg Aux Htg Preheat Humid if Opt Vent Total -2.1 0.0 Lvg °F 80 62.5 86.8 0 0.0 0.0 11 24.0 54.5 0.0 0 0.0 0.0 0.0 0 0.0 0.0 -2.5 TRACE® 700 v6.2.6.5 calculated at 08:53 AM on 11/28/2011 Alternative - 1 System Checksums Report Page 9 of 25 Room Checksums By MMFS 210 Office COOLING COIL PEAK Peaked at Time Outside Air: Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass /Door Cond Wall Cond Partition /Door Floor Adjacent Floor Infiltration Sub Total = => Internal Loads Lights People Misc Sub Total = => Ceiling Load Ventilation Load Adj Air Trans Heat Dehumid. Ov Sizing Ov /Undr Sizing Exhaust Heat Sup. Fan Heat ReL Fan Heat Duct Heat Pkup Underfir Sup Ht Pkup Supply Air Leakage Grand Total = => Mo /Hr: 7 / 13 OADB/WB /HR: 80 / 65 / 72 CLG SPACE PEAK Mo /Hr: 7 / 12 OADB: 78 Space Plenum Net Percent Space Sens. + Lat. Sens. + Lat Total Of Total Sensible Btu /h Btu /h Btu /h ( %) Btu /h o o 0 0 0 0 0 0 0 0 0 101 101 5 0 0 0 0 0 0 0 0 0 0 0 301 143 443 21 348 0 0 0 0 0 0 0 0 O 0 0 0 0 69 69 3 16 370 244 614 29 363 216 54 270 13 216 450 0 450 21 250 647 0 647 31 647 1,312 54 1,366 65 1,112 48 -48 0 0 41 0 0 128 6 0 0 0 0 0 0 0 O 0 0 0 -31 -31 -1 40 2 0 0 0 0 0 0 0 0 0 0 0 Percent Of Total (%) Envelope Loads 0 Skylite Solar 0 Skylite Cond 0 Roof Cond 0 Glass Solar 0 Glass /Door Cond 23 Wall Cond 0 Partition /Door 0 Floor 0 Adjacent Floor 1 Infiltration 24 Sub Total = => Internal Loads 14 Lights 16 People 43 Misc 73 Sub Total = => 3 0 0 0 Ceiling Load Ventilation Load Adj Air Trans Heat Ov /Undr Sizing Exhaust Heat OA Preheat Diff. RA Preheat Diff. Additional Reheat System Plenum Heat Underfir Sup Ht Pkup Supply Air Leakage 1,730 219 2,117 100.00 1,517 100.00 Grand Total =_> HEATING COIL PEAK Mo /Hr: Heating Design OADB: 24 Space Peak Coil Peak Percent Space Sens Tot Sens Of Total Btu /h Btu /h I1/4) O 0 0.00 0 0 0.00 0 -332 18.15 0 0 0.00 0 0 0.00 -368 -536 29.34 0 0 0.00 O 0 0.00 0 0 0.00 -266 -266 14.57 -634 -1.134 62.06 O 0 0.00 O 0 0.00 -198 -198 10.81 -198 -198 10.81 -101 0 0.00 O -492 26.95 O 0 0 O 0 0.00 67 -3.64 0 0.00 -139 7.59 0 0.00 69 -3.78 0 0.00 0 0.00 -933 -1,827 100.00 Main Clg Aux Clg Opt Vent Total Total Capacity ton MBh 0.2 2.1 0.0 0.0 0.0 0.0 0.2 2.1 COOLING COIL SELECTION Sens Cap. Coil Airflow Enter DB/WB /HR MBh cfm °F °F gr /Ib 1.8 68 77.3 62.6 62.6 0.0 0 0.0 0.0 0.0 0.0 0 0.0 0.0 0.0 Leave DB/WB /HR °F °F or/lb 54.5 51.8 53.8 0.0 0.0 0.0 0.0 0.0 0.0 Project Name: Dataset Name: 7317040 Group Health AMB Pharmacy GH1.TRC AREAS Gross Total Glass ft' (%) Floor 79 Part 0 Int Door 0 ExFIr 0 Roof 79 Wall 120 Ext Door 0 O 0 O 0 O 0 TEMPERATURES Cooling Heating 55.0 82.3 76.9 66.0 76.9 66.0 77.3 46.2 0.1 0.0 0.1 0.0 0.4 0.0 SADB Ra Plenum Return Ret/OA Fn MtrTD Fn BIdTD Fn Frict AIRFLOWS Cooling 69 69 69 69 10 10 5 21 74 15 0 0 0 0 Diffuser Terminal Main Fan Sec Fan Nom Vent AHU Vent Infil MinStop/Rh Return Exhaust Rm Exh Auxiliary Leakage Dwn Leakage Ups Heating 69 69 21 69 10 10 5 21 26 15 0 0 0 0 ENGINEERING CKS OA cfmlft' cfmlton ft'lton Btu/hr-ft' No. People Cooling 14.1 0.87 391.30 447.76 26.80 1 Heating 14.1 0.87 -23.12 HEATING COIL SELECTION Capacity Coil Airflow MBh cfm Main Htg Aux Htg Preheat Humidif Opt Vent Total -1.5 0.0 Ent Lvg °F °F 69 62.5 82.3 0 0.0 0.0 -0.3 10 24.0 54.5 0.0 0 0.0 0.0 0.0 0 0.0 0.0 -1.8 TRACE® 700 v6.2.6.5 calculated at 08:53 AM on 11/28/2011 Alternative - 1 System Checksums Report Page 10 of 25 Room Checksums By MMFS 211 Office COOLING COIL PEAK Peaked at Time: Outside Air: Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass /Door Cond Wall Cond Partition /Door Floor Adjacent Floor Infiltration Sub Total = => Internal Loads Lights People Misc Sub Total = => Ceiling Load Ventilation Load Adj Air Trans Heat Dehumid. Ov Sizing OvlUndr Sizing Exhaust Heat Sup. Fan Heat Ret Fan Heat Duct Heat Pkup Underflr Sup Ht Pkup Supply Air Leakage Grand Total = => Space Sens. + Lat Btu /h Mo /Hr: 7 / 13 OADB/WB /HR: 80 / 65 / 72 CLG SPACE PEAK Mo /Hr: 7 / 12 OADB: 78 Plenum Net Percent Space Sens. + Lat Total Of Total Sensible Btu /h Btu /h ( %) Btu /h 0 0 0 0 0 0 0 0 0 0 0 97 97 5 0 0 0 0 0 0 0 0 0 0 0 300 143 443 21 348 0 0 0 0 0 0 0 0 0 0 0 0 0 67 67 3 15 367 240 607 29 363 208 52 259 12 208 450 0 450 22 250 642 0 642 31 642 1,299 52 1,351 65 1,099 46 -46 0 0 40 0 0 126 6 0 0 0 0 0 0 0 0 0 0 0 -31 -31 -1 4D 2 0 0 0 0 0 0 0 0 0 0 0 1,712 215 2,093 100.00 1,501 Percent Of Total ( %) Envelope Loads O Skylite Solar 0 Skylite Cond 0 Roof Cond 0 Glass Solar 0 Glass /Door Cond 23 Wall Cond 0 Partition /Door 0 Floor O Adjacent Floor 1 Infiltration 24 Sub Total = => Internal Loads 14 Lights 17 People 43 Misc 73 Sub Total = => 3 Ceiling Load 0 Ventilation Load 0 Adj Air Trans Heat Ov /Undr Sizing O Exhaust Heat OA Preheat Diff. RA Preheat Diff. Additional Reheat System Plenum Heat Underflr Sup Ht Pkup Supply Air Leakage 100.00 Grand Total = => HEATING COIL PEAK Mo /Hr. Heating Design OADB: 24 Space Peak Coil Peak Percent Space Sens Tot Sens Of Total Btu/h Btu /h ( %) 0 0 0.00 0 0 0.00 0 -319 17.79 0 0 0.00 0 0 0.00 -368 -536 29.88 0 0 0.00 O 0 0.00 O 0 0.00 -256 -256 14.28 -624 -1,111 61.95 O 0 0.00 0 0 0.00 -190 -190 10.60 -190 -190 10.60 -97 0 0.00 O -483 26.95 0 0 0 0 0 0.00 65 -3.62 O 0.00 -138 7.71 0 0.00 64 -3.59 0 0.00 O 0.00 -911 -1,793 100.00 Main Clg Aux Clg Opt Vent Total Total Capacity ton MBh 0.2 2.1 0.0 0.0 0.0 0.0 0.2 2.1 COOLING COIL SELECTION Sens Cap. Coil Airflow Enter DB/WB /HR MBh cfm °F °F gr/lb 1.8 67 77.3 62.6 62.6 0.0 0 0.0 0.0 0.0 0.0 0 0.0 0.0 0.0 Leave DBIWBIHR °F °F gr/Ib 54.5 51.8 53.8 0.0 0.0 0.0 0.0 0.0 0.0 Project Name: Dataset Name: 7317040 Group Health AMB Pharmacy GH1.TRC AREAS Gross Total Glass Floor 76 Part 0 Int Door 0 ExFlr 0 Roof 76 Wall 120 Ext Door 0 ft' ( %) 0 0 0 0 0 0 TEMPERATURES Cooling Heating 55.0 82.1 76.9 66.0 76.9 66.0 77.3 46.4 0.1 0.0 0.1 0.0 0.4 0.0 SADB Ra Plenum Return Ret/OA Fn MtrTD Fn BIdTD Fn Frict AIRFLOWS Cooling 68 68 68 68 10 10 5 21 73 15 0 0 0 0 Diffuser Terminal Main Fan Sec Fan Nom Vent AHU Vent Infll MinStop /Rh Return Exhaust Rm Exh Auxiliary Leakage Dwn Leakage Ups Heating 68 68 21 68 10 10 5 21 26 15 0 0 0 0 ENGINEERING CKS % OA cfmlft cfm/ton ft'lto n Btulhr•ft' No. People Cooling 14.0 0.90 391.73 435.76 27.54 1 Heating 14.0 0.90 -23.59 HEATING COIL SELECTION Capacity Coil Airflow Ent MBh cfm °F Main Htg Aux Htg Preheat Humidif Opt Vent Total -1.5 0.0 -0.3 Lvg °F 68 62.5 82.1 0 0.0 0.0 10 24.0 54.5 0.0 0 0.0 0.0 0.0 0 0.0 0.0 -1.8 TRACE® 700 v6.2.6.5 calculated at 08:53 AM on 11/28/2011 Alternative - 1 System Checksums Report Page 11 of 25 Room Checksums By MMFS 212 Office COOLING COIL PEAK Peaked at Time: Outside Air: Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass /Door Cond Wall Cond Partition /Door Floor Adjacent Floor Infiltration Sub Total = => Internal Loads Lights People Misc Sub Total = => Ceiling Load Ventilation Load Adj Air Trans Heat Dehumid. Ov Sizing OvlUndr Sizing Exhaust Heat Sup. Fan Heat Ret. Fan Heat Duct Heat Pkup Underfir Sup Ht Pkup Supply Air Leakage Grand Total = => Mo /Hr: 7 / 13 OADB/WB /HR: 80 / 65 / 72 Space Plenum Sens. + Lat. Sens. + Lat Btu /h Btu /h Net Percent Total Of Total Btu /h ( %) O 0 0 0 O 0 0 0 O 100 100 5 o o 0 0 o o 0 0 301 143 443 21 0 0 0 O 0 0 a o 0 0 68 68 3 369 243 612 29 213 53 266 450 0 450 645 0 645 1.308 53 1,361 CLG SPACE PEAK Mo /Hr: 7 / 12 OADB: 78 Space Percent Sensible Of Total Btu /h ( %) 0 0 0 0 0 0 0 o 0 0 348 23 0 0 0 0 0 0 15 1 363 24 13 213 14 21 250 17 31 645 43 Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass /Door Cond Wall Cond Partition /Door Floor Adjacent Floor Infiltration Sub Total = => Internal Loads Lights People Misc 65 1,108 73 Sub Total =_> 47 -47 0 0 O 0 127 6 0 0 0 0 0 O 0 0 -31 -31 -1 40 2 0 0 0 0 0 0 0 0 0 0 0 1,724 217 2,109 100.00 41 3 0 0 0 0 0 0 Ceiling Load Ventilation Load Adj Air Trans Heat Ov /Undr Sizing Exhaust Heat OA Preheat Diff. RA Preheat Diff. Additional Reheat System Plenum Heat Underfir Sup Ht Pkup Supply Air Leakage 1,512 100.00 Grand Total =_> HEATING COIL PEAK Mo /Hr: Heating Design OADB: 24 Space Peak Coil Peak Percent Space Sens Tot Sens Of Total Btu /h Btu /h ( %) 0 0 0.00 0 0 0.00 0 -327 18.03 0 0 0.00 0 0 0.00 -368 -536 29,52 0 0 0.00 0 0 0.00 0 0 0.00 -263 -263 14.48 -631 -1,126 62.02 0 0 0.00 0 0 0.00 -195 -195 10.74 -195 -195 10.74 -100 0 0.00 O -489 26.95 0 0 0 O 0 0.00 66 -3.63 0 0.00 -139 7.63 0 0.00 67 -3.71 0 0.00 0 0.00 -926 -1,815 100.00 Main Clg Aux Clg Opt Vent Total Total Capacity ton MBh 0.2 2.1 0.0 0.0 0.0 0.0 0.2 2.1 COOLING COIL SELECTION Sens Cap. Coil Airflow Enter DB/WB /HR MBh cfm °F °F gr/lb 1.8 68 77.3 62.6 0.0 0 0.0 0.0 0.0 0 0.0 0.0 62.6 0.0 0.0 Leave DB/WBIHR °F °F gr /lb 54.5 51.8 0.0 0.0 0.0 0.0 53.8 0.0 0.0 Project Name: Dataset Name: 7317040 Group Health AMB Pharmacy GH1.TRC AREAS Gross Total Glass Floor 78 Part 0 Int Door 0 ExFlr 0 Roof 78 Wall 120 Ext Door 0 ft' ( %) O 0 O 0 O 0 TEMPERATURES Cooling Heating 55.0 82.2 76.9 66.0 76.9 66.0 77.3 46.3 0.1 0.0 0.1 0.0 0.4 0.0 SADB Ra Plenum Return Ret/OA Fn MtrTD Fn BIdTD Fn Frict AIRFLOWS Cooling 69 69 69 69 10 10 5 21 74 15 0 0 0 0 Diffuser Terminal Main Fan Sec Fan Nom Vent AHU Vent Infil MinStop /Rh Return Exhaust Rm Exh Auxiliary Leakage Dwn Leakage Ups Heating 69 69 21 69 10 10 5 21 26 15 0 0 0 0 ENGINEERING CKS OA cfm/ft' cfm/ton ft=/ton Btu/hr•ft' No. People Cooling 14.1 0.88 391.44 443.76 27.04 1 Heating 14.1 0.88 -23.28 HEATING COIL SELECTION Capacity Coil Airflow Ent MBh cfm °F Main Htg Aux Htg Preheat Humidif Opt Vent Total -1.5 0.0 -0.3 Lvg °F 69 62.5 82.2 0 0.0 0.0 10 24.0 54.5 0.0 0 0.0 0.0 0.0 0 0.0 0.0 -1.8 TRACE® 700 v6.2.6.5 calculated at 08:53 AM on 11/28/2011 Alternative - 1 System Checksums Report Page 12 of 25 Room Checksums By MMFS 213 Workstations COOLING COIL PEAK Peaked at Time Outside Air: Envelope Loads Skylite Solar Skylite Cond Roof Coed Glass Solar Glass /Door Cond Wall Cond Partition /Door Floor Adjacent Floor Infiltration Sub Total = => Internal Loads Lights People Misc Sub Total =_> Ceiling Load Ventilation Load Adj Air Trans Heat Dehumid. Ov Sizing Ov /Undr Sizing Exhaust Heat Sup. Fan Heat Ret. Fan Heat Duct Heat Pkup Underflr Sup Ht Pkup Supply Air Leakage Grand Total = => CLG SPACE PEAK Mo /Hr: 7 / 14 Mo /Hr: 7 / 12 OADB/WB /HR: 81 / 66 / 74 OADB: 78 Space Plenum Sens. + Lat. Sens. + Lat Btu /h Btu /h Net Percent Space Percent Total Of Total Sensible Of Total Btu /h ( %) Btu /h ( %) 0 0 0 0 0 0 0 0 0 0 0 0 0 723 723 5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 895 415 1,310 10 1,300 13 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 422 422 3 87 1 1,317 1,138 2,455 18 1,387 14 Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass /Door Cond Wall Cond Partition /Door Floor Adjacent Floor Infiltration Sub Total = => Internal Loads 1,212 303 1,515 11 1,212 13 Lights 3,600 0 3,600 27 2,000 21 People 4,853 0 4,853 36 4,853 50 Misc 9,666 303 9,969 74 8,066 83 Sub Total =_> 310 -310 0 0 232 2 0 0 949 7 0 0 0 0 0 0 0 0 0 0 0 0 0 0 -233 -233 -2 256 2 0 0 0 0 0 0 0 0 0 0 0 Ceiling Load Ventilation Load Adj Air Trans Heat Ov /Undr Sizing Exhaust Heat OA Preheat Diff. RA Preheat Diff. Additional Reheat System Plenum Heat Underflr Sup Ht Pkup Supply Air Leakage 11,292 898 13,395 100.00 9,685 100.00 Grand Total = => HEATING COIL PEAK Mo /Hr: Heating Design OADB: 24 Space Peak Coil Peak Percent Space Sens Tot Sens Of Total Btu /h Btu /h (% ) 0 0 0.00 0 0 0.00 0 -1,863 17.93 0 0 0.00 0 0 0.00 -1,362 -1,983 19.08 0 0 0.00 0 0 0.00 0 0 0.00 -1,496 -1,496 14.40 -2,858 -5,342 51.41 0 0 0.00 0 0 0,00 -1,110 -1,110 10.68 -1,110 -1,110 10.68 -568 0 0.00 0 -3,368 32.42 O 0 0 O 0 0.00 427 -4.11 O 0.00 -829 7.98 O 0.00 -168 1.62 0 0.00 0 0.00 -4,535 - 10,391 100.00 Main Clg Aux Clg Opt Vent Total COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DB/WB /HR ton MBh MBh cfm °F °F gr/lb 1.1 13.4 11.1 431 77.9 62.9 63.0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 0 0.0 0.0 0.0 13.4 Leave DB/WB /HR °F °F gr/Ib 54.5 52.1 55.2 0.0 0.0 0.0 0.0 0.0 0.0 Project Name: Dataset Name: 7317040 Group Health AMB Pharmacy GH1.TRC AREAS Gross Total Glass Floor 444 Part 0 Int Door 0 ExFIr 0 Roof 444 Wall 444 Ext Door 0 ft' (%) O 0 O 0 0 0 TEMPERATURES Cooling Heating 55.0 79.4 77.2 66.0 77.2 66.0 77.9 44.8 0.1 0.0 0.1 0.0 0.4 0.0 SADB Ra Plenum Return Ret/OA Fn MtrTD Fn BIdTD Fn Frict AIRFLOWS Cooling 441 441 441 441 67 67 30 132 470 96 0 0 0 0 Diffuser Terminal Main Fan Sec Fan Nom Vent AHU Vent Infil MinStop /Rh Return Exhaust Rm Exh Auxiliary Leakage Dwn Leakage Ups Heating 441 441 132 441 67 67 30 132 162 96 0 0 0 0 ENGINEERING CKS Cooling Heating 15.1 15.1 0.99 0.99 394.80 397.75 30.17 -23.40 8 OA cfmlft' cfmlton ft' /ton Btu/hr•ft' No. People HEATING COIL SELECTION Capacity Coil Airflow Ent Lvg MBh cfm °F °F Main Htg Aux Htg Preheat Humidif Opt Vent Total -8.2 441 62.5 79.4 0.0 0 0.0 0.0 -2.2 67 24.0 54.5 0.0 0 0.0 0.0 0.0 0 0.0 0.0 -10.4 TRACE® 700 v6.2.6.5 calculated at 08:53 AM on 11/28/2011 Alternative - 1 System Checksums Report Page 13 of 25 Room Checksums By MMFS 214 Interior Office COOLING COIL PEAK Peaked at Time Mo /Hr. 7 / 16 Outside Air: OADB/WB /HR: 81 / 65 / 68 Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass /Door Cond Wall Cond Partition /Door Floor Adjacent Floor Infiltration Sub Total = => Internal Loads Lights People Misc Sub Total = => Ceiling Load Ventilation Load Adj Air Trans Heat Dehumid. Ov Sizing OvlUndr Sizing Exhaust Heat Sup. Fan Heat Ret. Fan Heat Duct Heat Pkup Underflr Sup Ht Pkup Supply Air Leakage Grand Total = => Space Plenum Sens. + Lat. Sens. + Lat Btu /h Btu /h 0 0 0 0 0 0 0 0 0 0 0 CLG SPACE PEAK Mo /Hr: 7 / 20 OADB: 73 Net Percent Space Percent Total Of Total Sensible Of Total Btu /h ( %I Btu /h ( %) 0 0 0 0 0 0 0 0 0 0 2,679 2.679 12 0 0 0 0 0 0 0 0 0 0 0 0 O 0 0 0 0 O 0 0 0 O 0 0 0 0 0 0 0 0 0 0 0 0 2,679 2.679 12 0 0 3.140 785 3,925 18 3.140 20 5,400 0 5,400 25 3,000 19 8.106 0 8,106 37 8.106 52 16,646 785 17,431 80 14,246 92 1.025 -1.025 0 0 1,248 8 0 0 1,533 7 0 0 0 0 0 0 0 0 0 0 0 0 0 0 -399 -399 -2 412 2 O 0 0 0 0 0 0 0 0 0 0 Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass /Door Cond Wall Cond Partition /Door Floor Adjacent Floor Infiltration Sub Total = => Internal Loads Lights People Misc Sub Total = => Ceiling Load Ventilation Load Adj Air Trans Heat Ov /Undr Sizing Exhaust Heat OA Preheat Diff. RA Preheat Diff. Additional Reheat System Plenum Heat Underflr Sup Ht Pkup Supply Air Leakage 17,671 2.040 21,656 100.00 15,494 100.00 Grand Total =_> HEATING COIL PEAK Mo /Hr: Heating Design OADB: 24 Space Peak Space Sens Btu /h 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 -1,470 0 0 0 -1,470 Coil Peak Tot Sens Btu /h Percent Of Total ( %) O 0.00 O 0,00 -4,826 41.65 0 0.00 O 0.00 0 0.00 0 0.00 0 0.00 O 0.00 O 0.00 -4,826 41.65 O 0.00 O 0.00 O 0.00 0 0.00 0 0.00 -6,520 56.27 O 0 0 0.00 572 -4.94 0 0.00 -1,043 9.00 0 0.00 231 -1.99 O 0.00 O 0.00 - 11,587 100.00 Main Clg Aux Clg 0.0 Opt Vent 0.0 Total Capacity ton MBh 1.8 21.7 0.0 Total 1.8 0.0 21.7 COOLING COIL SELECTION Sens Cap. Coil Airflow Enter DB/WB /HR MBh cfm °F °F gr /Ib 18.6 695 78.5 62.9 62.3 0.0 0 0.0 0.0 0.0 0.0 0 0.0 0.0 0.0 Leave DBM/BIHR °F °F gr/lb 54.5 52.2 55.4 0.0 0.0 0.0 0.0 0.0 0.0 Project Name: Dataset Name: 7317040 Group Health AMB Pharmacy GH1.TRC AREAS Gross Total Glass Floor 1,150 Part 0 Int Door 0 ExFlr 0 Roof 1,150 Wall 0 Ext Door 0 ft' ( %I O 0 O 0 0 0 TEMPERATURES Cooling Heating 55.0 71.9 77.8 66.0 77.8 66.0 78.5 40.4 0.1 0.0 0.1 0.0 0.4 0.0 SADB Ra Plenum Return Ret/OA Fn MtrTD Fn BIdTD Fn Frict AIRFLOWS Cooling 705 705 705 705 0 0 0 212 705 0 0 0 Diffuser Terminal Main Fan Sec Fan Nom Vent AHU Vent Infil MinStoplRh Return Exhaust Rm Exh Auxiliary Leakage Dwn Leakage Ups 0 0 Heating 705 705 212 705 129 129 0 212 212 129 0 0 0 0 ENGINEERING CKS % OA cfmlft' cfm/ton fV /ton Btu/hr•ft No. People Cooling 18.3 0.61 390.66 637.23 18.83 12 Heating 18.3 0.61 -10.08 HEATING COIL SELECTION Capacity Coil Airflow Ent MBh cfm °F Main Htg Aux Htg Preheat Humidif Opt Vent Total -7.3 0.0 -4.3 Lvg °F 705 62.5 71.9 0 0.0 0.0 129 24.0 54.5 0.0 0 0.0 0.0 0.0 0 0.0 0.0 -11.6 TRACE® 700 v6.2.6.5 calculated at 08:53 AM on 11/28/2011 Alternative - 1 System Checksums Report Page 14 of 25 Room Checksums By MMFS 215 Hall COOLING COIL PEAK CLG SPACE PEAK Peaked at Time Mo /Hr: 7 / 20 Outside Air: OADB /WB /HR: 73 / 59 / 54 Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass /Door Cond Wall Cond Partition /Door Floor Adjacent Floor Infiltration Sub Total = => Internal Loads Lights People Misc Sub Total =_> Ceiling Load Ventilation Ldad Adj Air Trans Heat Dehumid. Ov Sizing Ov /Undr Sizing Exhaust Heat Sup. Fan Heat Ret. Fan Heat Duct Heat Pkup Underfir Sup Ht Pkup Supply Air Leakage Grand Total = => Space Plenum Sens. + Lat. Sens. + Lat Btu /h Btu /h 0 0 0 0 0 0 0 0 0 0 0 Net Percent Total Of Total Btu /h (% ) O 0 0 0 0 0 550 550 37 O 0 0 0 0 0 O 0 0 0 0 O 0 0 0 0 O 0 550 550 37 491 123 614 41 0 0 0 0 307 0 307 21 799 123 922 62 195 -195 0 0 0 0 0 0 0 0 0 0 0 0 0 0 o o 0 27 2 0 0 0 0 0 0 O 0 0 0 0 994 478 1,498 100.00 Mo /Hr: 7 / 20 OADB: 73 Space Percent Sensible Of Total Btu /h (%) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 491 49 0 0 307 31 799 80 195 20 0 0 0 0 0 0 Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass /Door Cond Wall Cond Partition /Door Floor Adjacent Floor Infiltration Sub Total = => Internal Loads Lights People Misc Sub Total =_> Ceiling Load Ventilation Load Adj Air Trans Heat OvlUndr Sizing Exhaust Heat OA Preheat Diff. RA Preheat Diff. Additional Reheat System Plenum Heat Underflr Sup Ht Pkup Supply Air Leakage 994 100.00 Grand Total = => HEATING COIL PEAK Mo /Hr: Heating Design OADB: 24 Space Peak Coil Peak Space Sens Tot Sens Btu /h Btu /h 0 0 0 0 O -755 0 0 O 0 0 0 o 0 O 0 O 0 O 0 0 -755 0 0 0 0 -230 0 0 0 -230 0 0 0 Percent Of Total (%) 0.00 0.00 78.39 0.00 0.00 0.00 0.00 0.00 0.00 0.00 78.39 0.00 0.00 0.00 0 0.00 0 -546 0 0 48 0 -35 0 325 0 0 0.00 56.65 0 0.00 -4.97 0.00 3.63 0.00 -33.71 0.00 0.00 -964 100.00 Main Clg Aux Clg Opt Vent Total Total Capacity ton MBh 0.1 1.5 0.0 0.0 0.0 0.0 0.1 1.5 COOLING COIL SELECTION Sens Cap. Coil Airflow Enter DBIWB /HR MBh cfm °F °F gr/lb 1.5 45 78.4 62.6 61.0 0.0 0 0.0 0.0 0.0 0.0 0 0.0 0.0 0.0 Leave DBIWB /HR °F °F gr/lb 54.5 51.1 51.2 0.0 0.0 0.0 0.0 0.0 0.0 Project Name: Dataset Name: 7317040 Group Health AMB Pharmacy GH1.TRC AREAS Gross Total Glass Floor 180 Part 0 Int Door 0 ExFlr 0 Roof 180 Wall 0 Ext Door 0 ft= VA) 0 0 0 0 0 0 TEMPERATURES Cooling Heating 55.0 74.6 78.4 66.0 78.4 66.0 78.4 32.6 0.1 0.0 0.1 0.0 0.4 0.0 SADB Ra Plenum Return RetIOA Fn MtrTD Fn BIdTD Fn Frict AIRFLOWS Cooling 45 45 45 45 0 0 0 14 45 0 0 0 0 0 Diffuser Terminal Main Fan Sec Fan Nom Vent AHU Vent Infil MinStop /Rh Return Exhaust Rm Exh Auxiliary Leakage Dwn Leakage Ups Heating 45 45 14 45 11 11 0 14 14 11 0 0 0 0 ENGINEERING CKS OA cfm/fr cfm /ton ft° /ton Btulhr•fr No. People Cooling 0.0 0.25 362.22 1,441.55 8.32 0 Heating 23.9 0.25 -5.35 HEATING COIL SELECTION Capacity Coil Airflow Ent MBh cfm °F Main Htg Aux Htg Preheat Humidif Opt Vent Total -0.6 0.0 -0.4 Lvg °F 45 62.5 74.6 0 0.0 0.0 11 24.0 54.5 0.0 0 0.0 0.0 0.0 0 0.0 0.0 -1.0 TRACE® 700 v6.2.6.5 calculated at 08:53 AM on 11/28/2011 Alternative - 1 System Checksums Report Page 15 of 25 Room Checksums By MMFS 216 Interior Office COOLING COIL PEAK Peaked at Time: Outside Air: Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass /Door Cond Wall Cond Partition /Door Floor Adjacent Floor Infiltration Sub Total = => Internal Loads Lights People Misc Sub Total = => Ceiling Load Ventilation Load Adj Air Trans Heat Dehumid. Ov Sizing Ov /Undr Sizing Exhaust Heat Sup. Fan Heat Ret. Fan Heat Duct Heat Pkup Underflr Sup Ht Pkup Supply Air Leakage Grand Total = => Mo /Hr: 7 / 16 OADB/WB /HR: 81 / 65 / 68 Space Plenum Sens. + Lat Sens. + Lat Btu /h Btu /h 0 0 O 0 0 2,029 O 0 0 0 0 0 0 0 0 0 0 0 2.029 Net Percent Total Of Total Btu /h ( %) 0 0 O 0 2,029 12 O 0 O 0 O 0 O 0 0 0 O 0 O 0 2,029 12 2,378 595 2,973 18 4,050 0 4,050 25 6,094 0 6,094 37 12,522 595 13,117 80 777 -777 0 O 0 1,156 O 0 0 O 0 -301 -301 310 0 0 0 0 0 0 0 13,299 0 7 0 0 0. -2 2 0 0 0 0 1,546 16.311 100.00 CLG SPACE PEAK Mo /Hr: 7 / 20 OADB: 73 Space Percent Sensible Of Total Btu /h ( %) Envelope Loads O 0 Skylite Solar O 0 Skylite Cond O 0 Roof Cond 0 0 Glass Solar O 0 ' Glass /Door Cond O 0 Wall Cond 0 0 Partition /Door 0 0 Floor O 0 Adjacent Floor O 0 Infiltration 0 0 Sub Total = => 2,378 20 2,250 19 6,094 52 10,722 92 945 8 0 0 O 0 0 0 11,667 100.00 Internal Loads Lights People Misc Sub Total = => Ceiling Load Ventilation Load Adj Air Trans Heat Ov /Undr Sizing Exhaust Heat OA Preheat Diff. RA Preheat Diff. Additional Reheat System Plenum Heat Underflr Sup Ht Pkup Supply Air Leakage Grand Total = => HEATING COIL PEAK Mo /Hr: Heating Design OADB: 24 Space Peak Coil Peak Space Sens Tot Sens Btu /h Btu /h 0 0 0 0 0 -3,655 0 0 0 0 0 0 0 0 O 0 O 0 0 0 O -3,655 Percent Of Total (%) 0.00 0.00 41.84 0.00 0.00 0.00 0.00 0.00 0.00 0.00 41.84 0 0 0.00 O 0 0.00 0 0 0.00 0 0 0.00 -1,113 0 0 0 -1,113 0 -4,916 0 0 431 0 -784 0 188 0 0 0.00 56.28 0 0.00 -4.94 0.00 8.97 0.00 -2.16 0.00 0.00 -8,736 100.00 Total Capacity ton MBh Main Clg 1.4 16.3 Aux Clg 0.0 0.0 Opt Vent 0.0 0.0 Total 1.4 16.3 COOLING COIL SELECTION Sens Cap. Coil Airflow Enter DB/WB /HR MBh cfm °F °F gr/Ib 14.0 523 78.5 62.9 62.3 0.0 0 0.0 0.0 0.0 Leave DB/WB/HR °F °F grub 54.5 52.2 55.4 0.0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Project Name: Dataset Name: 7317040 Group Health AMB Pharmacy GH1.TRC AREAS Gross Total Glass ft' ( %) Floor 871 Part 0 Int Door 0 ExFlr 0 Roof 871 Wall 0 Ext Door 0 O 0 O 0 O 0 TEMPERATURES Cooling Heating 55.0 71.9 77.8 66.0 77.8 66.0 78.5 40.3 0.1 0.0 0.1 0.0 0.4 0.0 SADB Ra Plenum Return Ret/OA Fn MtrTD Fn BIdTD Fn Frict AIRFLOWS Cooling 531 531 531 531 0 0 0 159 531 0 0 0 0 0 Diffuser Terminal Main Fan Sec Fan Nom Vent AHU Vent Infll MinStop/Rh Return Exhaust Rm Exh Auxiliary Leakage Dwn Leakage Ups Heating 531 531 159 531 97 97 0 159 159 97 0 0 0 0 ENGINEERING CKS OA cfm/ft' cfmlton fY /ton Btu/hr-ft' No. People Cooling 18.3 0.61 390.58 640.79 18.73 9 Heating 18.3 0.61 -10.03 HEATING COIL SELECTION Capacity Coil Airflow Ent MBh cfm °F Main Htg Aux Htg Preheat Humidif Opt Vent Total -5.5 0.0 -3.3 Lvg °F 531 62.5 71.9 0 0.0 0.0 97 24.0 54.5 0.0 0 0.0 0.0 0.0 0 0.0 0.0 -8.7 TRACE® 700 v6.2.6.5 calculated at 08:53 AM on 11/28/2011 Alternative - 1 System Checksums Report Page 16 of 25 Room Checksums By MMFS 217 Interior Office COOLING COIL PEAK Peaked at Time: Outside Air: Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass /Door Cond Wall Cond Partition /Door Floor Adjacent Floor Infiltration Sub Total =_> Internal Loads Lights People Misc Sub Total = => Ceiling Load Ventilation Load Adj Air Trans Heat Dehumid. Ov Sizing OvlUndr Sizing Exhaust Heat Sup. Fan Heat Ret. Fan Heat Duct Heat Pkup Underflr Sup Ht Pkup Supply Air Leakage Grand Total = => Mo /Hr 7/16 OADB/WB /HR: 81 / 65 / 68 Space Plenum Sens. + Lat. Sens. + Lat Btu /h Btu /h 0 0 0 0 0 3,893 0 0 0 0 0 0 0 0 0 0 0 0 3,893 4,563 8,100 12,067 24,729 Net Percent Total Of Total Btu /h ( %) O 0 O 0 3,893 12 O 0 O 0 0 0 O 0 0 0 0 0 0 0 3,893 12 1,141 5,703 18 0 8,100 25 0 12,067 38 1,141 25,870 81 1,490 -1,490 0 0 O 0 2,262 7 0 0 0 0 0 O 0 0 -588 -588 -2 610 2 O 0 0 o 0 0 0 0 O 0 0 26,219 2,955 32,046 100.00 CLG SPACE PEAK Mo /Hr: 7 / 20 OADB: 73 Space Percent Sensible Of Total Btu /h (%) O 0 0 0 O 0 0 0 0 0 0 0 O 0 O 0 0 0 0 0 0 0 4,563 20 4,500 20 12,067 53 21,129 92 1,813 8 0 0 0 0 O 0 22,942 Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass /Door Cond Wall Cond Partition /Door Floor Adjacent Floor Infiltration Sub Total = => Internal Loads Lights People Misc Sub Total = => Ceiling Load Ventilation Load Adj Air Trans Heat OvlUndr Sizing Exhaust Heat OA Preheat Diff. RA Preheat Diff. Additional Reheat System Plenum Heat Underflr Sup Ht Pkup Supply Air Leakage 100.00 Grand Total = => Main CIg Aux Clg Opt Vent Total Total Capacity ton MBh 2.7 32.1 0.0 0.0 0.0 0.0 2.7 32.1 COOLING COIL SELECTION Sens Cap. Coil Airflow Enter DBIWB/HR MBh cfm °F °F gr/lb 27.5 1,029 78.5 62.9 0,0 0 0.0 0.0 62.3 0.0 0.0 0 0.0 0.0 0.0 Leave DB/WB /HR °F °F gr/Ib 54.5 52.2 55.4 0.0 0.0 0.0 0.0 0.0 0.0 Project Name: Dataset Name: 7317040 Group Health AMB Pharmacy GH1.TRC HEATING COIL PEAK Mo /Hr: Heating Design OADB: 24 Space Peak Coil Peak Space Sens Tot Sens Btu /h Btu /h 0 0 0 0 0 -7,012 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 -7,012 0 0 0 0 -2,136 0 0 0 -2,136 0 0 0 Percent Of Total ( %) 0.00 0.00 41.03 0.00 0.00 0.00 0.00 0.00 0.00 0.00 41.03 0.00 0.00 0,00 0 0.00 0 -9,617 0 0 843 0 -1,554 0 249 0 0 0.00 56.27 0 0.00 -4.93 0.00 9.09 0,00 -1.46 0.00 0.00 - 17,091 100.00 AREAS Gross Total Glass Floor 1,671 Part 0 Int Door 0 ExFlr 0 Roof 1,671 Wall 0 Ext Door 0 ft2 ( %) O 0 O 0 O 0 TEMPERATURES Cooling Heating 55.0 71.9 77.8 66.0 77.8 66.0 78.5 40.5 0.1 0.0 0.1 0.0 0.4 0.0 SADB Ra Plenum Return Ret/OA Fn MtrTD Fn BIdTD Fn Frict AIRFLOWS Cooling 1,044 1,044 1,044 1,044 0 0 0 313 1,044 0 0 0 0 0 Diffuser Terminal Main Fan Sec Fan Nom Vent AHU Vent Infil MinStoplRh Return Exhaust Rm Exh Auxiliary Leakage Dwn Leakage Ups Heating 1,044 1,044 313 1,044 190 190 0 313 313 190 0 0 0 0 ENGINEERING CKS OA cfm/fe cfm /ton futon Btu /hrft' No. People Cooling 18.2 0.62 390.92 625.73 19.18 18 Heating 18.2 0.62 -10.23 HEATING COIL SELECTION Capacity Coil Airflow Ent MBh cfm °F Main Htg Aux Htg Preheat Humidif Opt Vent Total -10.7 0.0 Lvg °F 1,044 62.5 71.9 0 0.0 0.0 -6.4 190 24.0 54.5 0.0 0 0.0 0.0 0.0 0 0.0 0.0 -17.1 TRACE® 700 v6.2.6.5 calculated at 08:53 AM on 11/28/2011 Alternative - 1 System Checksums Report Page 17 of 25 Room Checksums By MMFS 218 Interior Office COOLING COIL PEAK Peaked at Time: Outside Air: Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass /Door Cond Wall Cond Partition /Door Floor Adjacent Floor Infiltration Sub Total =_> Internal Loads Lights People Misc Sub Total = => Ceiling Load Ventilation Load Adj Air Trans Heat Dehumid. Ov Sizing Ov /Undr Sizing Exhaust Heat Sup. Fan Heat Ret. Fan Heat Duct Heat Pkup Underflr Sup Ht Pkup Supply Air Leakage Grand Total = => Mo /Hr: 7 / 15 OADB /WB /HR: 82 / 66 / 71 Space Plenum Sens. + Lat. Sens. + Lat Btu /h Btu /h 0 0 0 0 0 0 0 0 0 0 0 4,563 8,100 14,797 27,460 Net Percent Total Of Total Btu /h ( %) 0 0 0 0 0 0 3.306 3.306 9 0 0 0 0 0 0 0 0 0 0 0 0 0 O 0 0 0 0 3,306 3,306 9 1,141 5,703 0 8,100 0 14,797 1.141 28.600 1,331 -1,331 0 0 0 2,780 0 0 0 0 0 -525 -525 679 0 0 O 0 0 0 0 28,790 CLG SPACE PEAK Mo /Hr: 7 / 20 OADB: 73 Space Percent Sensible Of Total Btu /h (% ) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 16 4,563 18 23 4,500 18 42 14,797 58 82 23,860 93 0 8 0 0 0 2 0. 0. 0 0 2,590 34,840 100.00 1.813 7 0 0 0 0 0 0 Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass /Door Cond Wall Cond Partition/Door Floor Adjacent Floor Infiltration Sub Total = => Internal Loads Lights People Misc Sub Total = => Ceiling Load Ventilation Load Adj Air Trans Heat Ov /Undr Sizing Exhaust Heat OA Preheat Diff. RA Preheat Diff. Additional Reheat System Plenum Heat Underflr Sup Ht Pkup Supply Air Leakage 25,673 100.00 Grand Total =_> HEATING COIL PEAK Mo /Hr: Heating Design OADB: 24 Space Peak Space Sens Btu /h 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 -2,136 0 0 0 -2,136 Coil Peak Tot Sens Btu /h Percent Of Total (off) O 0.00 0 0.00 -7,012 38.72 0 0.00 O 0.00 O 0.00 O 0.00 O 0.00 O 0.00 O 0.00 -7,012 38.72 O 0.00 O 0.00 O 0.00 O 0.00 O 0.00 -9,617 53.09 O 0 0 0.00 843 -4.66 O 0.00 -2,025 11.18 O 0.00 -302 1.67 O 0.00 0 0.00 - 18,113 100.00 Main Clg Aux Clg Opt Vent Total Total Capacity ton MBh COOLING COIL SELECTION Sens Cap. Coil Airflow Enter DB/WB /HR MBh cfm °F °F gr /Ih 2.9 34.8 29.9 1,146 78.3 62.9 62.7 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 0 0.0 0.0 0.0 2.9 34.8 Leave DB/WB /HR °F °F gr /Ib 54.5 52.5 56.5 0.0 0.0 0.0 0.0 0.0 0.0 Project Name: Dataset Name: 7317040 Group Health AMB Pharmacy GH1.TRC AREAS Gross Total Glass Floor 1,671 Part 0 Int Door 0 ExFlr 0 Roof 1,671 Wall 0 Ext Door 0 ft (%) O 0 O 0 0 0 TEMPERATURES Cooling Heating 55.0 71.7 77.5 66.0 77.5 66.0 78.3 43.2 0.1 0.0 0.1 0.0 0.4 0.0 SADB Ra Plenum Return Ret/OA Fn MtrTD Fn BIdTD Fn Frict AIRFLOWS Cooling 1,168 1,168 1.168 1,168 0 0 0 350 1,168 0 0 0 0 0 Diffuser Terminal Main Fan Sec Fan Nom Vent AHU Vent Infil MinStop/Rh Return Exhaust Rm Exh Auxiliary Leakage Dwn Leakage Ups Heating 1,168 1,168 350 1,168 190 190 0 350 350 190 0 0 0 0 ENGINEERING CKS % OA cfm/ft' cfmlton ft'/ton Btu/hrft' No. People Cooling 16.3 0.70 402.36 575.55 20.85 18 Heating 16.3 0.70 -10.84 HEATING COIL SELECTION Capacity Coil Airflow Ent MBh cfm °F Main Htg Aux Htg Preheat Humidif Opt Vent Total -11.7 0.0 Lvg °F 1,168 62.5 71.7 0 0.0 0.0 -6.4 190 24.0 54.5 0.0 0 0.0 0.0 0.0 0 0.0 0.0 -18.1 TRACE® 700 v6.2.6.5 calculated at 08:53 AM on 11/28/2011 Alternative - 1 System Checksums Report Page '18 of 25 Room Checksums By MMFS 219 Conference COOLING COIL PEAK Peaked at Time: Mo /Hr: 7 / 15 Outside Air: OADB/WB /HR: 82 / 66 / 71 Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass /Door Cond Wall Cond Partition /Door Floor Adjacent Floor Infiltration Sub Total =_> Internal Loads Lights People Misc Sub Total =_> Ceiling Load Ventilation Load Adj Air Trans Heat Dehumid. Ov Sizing Ov /Undr Sizing Exhaust Heat Sup. Fan Heat Ret. Fan Heat Duct Heat Pkup Underflr Sup Ht Pkup Supply Air Leakage Grand Total = => Space Plenum Sens. + Lat. Sens. + Lat Btu /h Btu /h 0 0 0 0 0 0 0 0 0 0 0 Net Percent Total Of Total Btu /h ( %) 0 0 0 0 0 0 465 465 5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 465 465 5 642 160 802 8 5,400 0 5.400 55 2,113 0 2,113 22 8,155 160 8,315 85 187 -187 0 0 0 0 1,083 11 0 0 0 0 0 0 0 0 -205 -205 -2 160 2 0 0 0 0 0 0 0 0 0 0 0 8,342 234 9,818 100.00 CLG SPACE PEAK Mo /Hr: 7 / 20 OADB: 73 Space Percent Sensible Of Total Btu /h (%) Envelope Loads 0 0 Skylite Solar O 0 Skylite Cond 0 0 Roof Cond O 0 Glass Solar 0 0 Glass /Door Cond O 0 Wall Cond O 0 Partition /Door O 0 Floor O 0 Adjacent Floor O 0 Infiltration 0 0 Sub Total = => 642 3,000 2,113 5,755 Internal Loads 11 Lights 50 People 35 Misc 96 Sub Total = => 255 4 Ceiling Load 0 0 Ventilation Load 0 0 Adj Air Trans Heat OvlUndr Sizing 0 0 Exhaust Heat OA Preheat Diff. RA Preheat Diff. Additional Reheat System Plenum Heat Underflr Sup Ht Pkup Supply Air Leakage 6,010 100.00 Grand Total = => HEATING COIL PEAK Mo /Hr: Heating Design OADB: 24 Space Peak Space Sens Btu /h 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 -300 0 0 0 -300 Coil Peak Percent Tot Sens Of Total Btu /h (%) 0 0.00 O 0.00 -986 19.61 0 0.00 0 0.00 0 0.00 0 0.00 0 0.00 0 0.00 0 0.00 -986 19.61 0 0.00 0 0.00 0 0.00 0 0.00 0 0.00 -3,745 74.46 0 0 O 0.00 328 -6.53 0 0.00 -100 1.99 0 0.00 -526 10.47 O 0.00 0 0.00 -5,030 100.00 Main CIg Aux Clg Opt Vent Total Total Capacity ton MBh 0.8 9.8 0.0 0.0 0.0 0.0 0.8 9.8 COOLING COIL SELECTION Sens Cap. Coil Airflow Enter DB/WB /HR MBh cfm °F °F gr /Ib 6.9 270 78.7 63.3 63.7 0.0 0 0.0 0.0 0.0 0.0 0 0.0 0.0 0.0 Leave DB/WB /HR °F °F grub 54.5 50.7 49.9 0.0 0.0 0.0 0.0 0.0 0.0 Project Name: Dataset Name: 7317040 Group Health AMB Pharmacy GH1.TRC AREAS Gross Total Glass ft' ( %) Floor 235 Par 0 Int Door 0 ExFlr 0 Roof 235 Wall 0 Ext Door 0 O 0 O 0 O 0 TEMPERATURES Cooling Heating 55.0 71.0 77.5 66.0 77.5 66.0 78.7 28.1 0.1 0.0 0.1 0.0 0.4 0.0 SADB Ra Plenum Return Ret/OA Fn MtrTD Fn BIdTD Fn Frict AIRFLOWS Cooling 273 273 273 273 0 0 0 82 273 0 0 0 0 0 Diffuser Terminal Main Fan Sec Fan Nom Vent AHU Vent Infil MinStop /Rh Return Exhaust Rm Exh Auxiliary Leakage Dwn Leakage Ups Heating 273 273 82 273 74 74 0 82 82 74 0 0 0 0 ENGINEERING CKS OA cfm/ft' cfm/ton Felton Btu/hr•ft' No. People Cooling 27.1 1.16 334.22 287.22 41.78 12 Heating 27.1 1.16 -21.40 HEATING COIL SELECTION Capacity Coil Airflow Ent MBh cfm °F Main Htg Aux Htg Preheat Humidif Opt Vent Total -2.6 0.0 -2.5 Lvg °F 273 62.5 71.0 0 0.0 0.0 74 24.0 54.5 0.0 0 0.0 0.0 0.0 0 0.0 0.0 -5.0 TRACE® 700 v6.2.6.5 calculated at 08:53 AM on 11/28/2011 Alternative - 1 System Checksums Report Page 19 of 25 Room Checksums By MMFS 220 Interior Office COOLING COIL PEAK Peaked at Time. Outside Air: Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass /Door Cond Wall Cond Partition /Door Floor Adjacent Floor Infiltration Sub Total =_> Internal Loads Lights People Misc Sub Total = => Ceiling Load Ventilation Load Adj Air Trans Heat Dehumid. Ov Sizing Ov /Undr Sizing Exhaust Heat Sup. Fan Heat Ret. Fan Heat Duct Heat Pkup Underflr Sup Ht Pkup Supply Air Leakage Grand Total = => Mo /Hr: 7 / 20 OADB /WB /HR: 73 / 59 / 54 Space Plenum Sens. + Lat. Sens. + Lat Btu /h Btu /h 0 0 0 0 O 2,521 O 0 0 0 0 0 0 0 O 0 0 O 2,521 Net Total Btu /h 0 0 2,521 0 0 0 0 0 0 0 2,521 Percent Of Total (%) 0 0 21 0 0 0 0 0 0 0 21 CLG SPACE PEAK Mo /Hr: 7 / 20 OADB: 73 Space Percent Sensible Of Total Btu /h (%) Envelope Loads 0 0 Skylite Solar O 0 Skylite Cond 0 0 Roof Cond 0 0 Glass Solar O 0 Glass /Door Cond O 0 Wall Cond 0 0 Partition/Door 0 0 Floor 0 0 Adjacent Floor 0 0 Infiltration 0 0 Sub Total =_> 2,253 563 2,816 24 2,253 27 2,250 0 2,250 19 1,250 15 3,968 0 3,968 34 3,968 47 8,470 563 9,033 77 7,470 89 895 -895 0 0 895 11 O 0 0 0 0 0 O 0 0 0 0 0 0 0 0 0 0 0 0 0 0 226 2 0 0 0 0 0 0 0 0 0 0 0 9,365 2,189 11,780 100.00 Internal Loads Lights People Misc Sub Total = => Ceiling Load Ventilation Load Adj Air Trans Heat OvlUndr Sizing Exhaust Heat OA Preheat Diff. RA Preheat Diff. Additional Reheat System Plenum Heat Underflr Sup Ht Pkup Supply Air Leakage 8,365 100.00 Grand Total = => HEATING COIL PEAK Mo /Hr: Heating Design OADB: 24 Space Peak Coil Peak Space Sens Tot Sens Btu /h Btu /h O 0 0 0 0 -3,462 0 0 0 0 O 0 0 0 0 0 O 0 O 0 O -3,462 0 0 0 0 -1,055 0 0 0 -1,055 a a 0 Percent Of Total I%) 0.00 0.00 51.84 0.00 0.00 0.00 0.00 0.00 0.00 0.00 51.84 0.00 0.00 0.00 0 0.00 0 -3,766 0 0 330 0 -502 0 720 0 0 0.00 56.38 0 0.00 -4.94 0.00 7.51 0.00 -10.78 0.00 0.00 -6 679 100.00 Main Clg Aux Clg Opt Vent Total Total Capacity ton MBh 1.0 11.8 0.0 0.0 0.0 0.0 1.0 11.8 COOLING COIL SELECTION Sens Cap. Coil Airflow Enter DB/WB /HR MBh cfm °F °F gr/lb 10.8 381 78.4 62.6 61.0 0.0 0 0.0 0.0 0.0 0.0 0 0.0 0.0 0.0 Leave DB/WB/HR °F °F gr/lb 54.5 51.9 54.3 0.0 0.0 0.0 0.0 0.0 0.0 Project Name: Dataset Name: 7317040 Group Health AMB Pharmacy GI-11 .TRC AREAS Gross Total Glass Floor 825 Part 0 Int Door 0 ExFIr 0 Roof 825 Wall 0 Ext Door 0 ft (%) 0 0 0 0 0 0 TEMPERATURES Cooling Heating 55.0 72.5 78.4 66.0 78.4 66.0 78.4 38.6 0.1 0.0 0.1 0.0 0.4 0.0 SADB Ra Plenum Return Ret/OA Fn MtrTD Fn BldTD Fn Frict AIRFLOWS Cooling 381 381 381 381 0 0 0 114 381 0 0 0 0 0 Diffuser Terminal Main Fan Sec Fan Nom Vent AHU Vent Infil MinStop/Rh Return Exhaust Rm Exh Auxiliary Leakage Dwn Leakage Ups Heating 381 381 114 381 75 75 0 114 114 75 0 0 0 0 ENGINEERING CKS OA cfmlfe cfm/ton ft' /ton Btu/hr•ft' No. People Cooling 0.0 0.46 387.75 840.40 14.28 5 Heating 19.6 0.46 -8.10 HEATING COIL SELECTION Capacity Coil Airflow Ent Lvg MBh cfm °F °F Main Htg Aux Htg Preheat Humidif Opt Vent Total -4.2 381 62.5 72.5 0.0 0 0.0 0.0 -2.5 75 24.0 54.5 0.0 0 0.0 0.0 0.0 0 0.0 0.0 -6.7 TRACE® 700 v6.2.6.5 calculated at 08:53 AM on 11/28/2011 Alternative - 1 System Checksums Report Page 20 of 25 Room Checksums By MMFS 221 Conference COOLING COIL PEAK Peaked at Time' Outside Air: Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass /Door Cond Wall Cond Partition /Door Floor Adjacent Floor Infiltration Sub Total = => Internal Loads Lights People Misc Sub Total = => Ceiling Load Ventilation Load Adj Air Trans Heat Dehumid. Ov Sizing OvlUndr Sizing Exhaust Heat Sup. Fan Heat Ret Fan Heat Duct Heat Pkup Underfir Sup Ht Pkup Supply Air Leakage Grand Total = => Mo /Hr: 7 / 15 OADB/WB /HR: 82 / 66 / 71 Space Plenum Sens. + Lat. Sens. + Lat Btu /h Btu /h 0 0 0 0 0 0 0 0 0 0 0 522 3,600 2.038 6,159 152 0 0 0 6,312 0 0 378 0 0 0 0 378 130 0 0 130 -152 0 -142 0 0 0 214 Net Percent Total Of Total Btu /h (%) O 0 0 0 378 5 0 0 O 0 0 0 O 0 0 0 0 0 0 0 378 5 652 9 3,600 49 2,038 28 6,290 85 0 752 0 0 0 -142 127 0 0 0 0 7,404 100.00 0 10' 0. 0, 0: -2' 2 0. 0 0 0 CLG SPACE PEAK Mo /Hr: 7 / 20 OADB: 73 Space Percent Sensible Of Total Btu /h (% O 0 0 0 0 0 O 0 O 0 0 0 O 0 0 0 0 0 0 0 0 0 522 11 2,000 42 2,038 43 4,559 96 207 4 O 0 0 0 0 0 Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass /Door Cond Wall Cond Partition /Door Floor Adjacent Floor Infiltration Sub Total = => Internal Loads Lights People Misc Sub Total = => Ceiling Load Ventilation Load Adj Air Trans Heat Ov /Undr Sizing Exhaust Heat OA Preheat Diff. RA Preheat Diff. Additional Reheat System Plenum Heat Underfir Sup Ht Pkup Supply Air Leakage 4,767 100.00 Grand Total =_> HEATING COIL PEAK Mo /Hr: Heating Design OADB: 24 Space Peak Space Sens Btu /h 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 -244 0 0 0 -244 Coil Peak Percent Tot Sens Of Total Btu /h I%) O 0.00 0 0.00 -802 21.37 0 0.00 0 0.00 0 0.00 O 0.00 0 0.00 0 0.00 O 0.00 -802 21.37 O 0.00 0 0.00 0 0.00 0 0.00 0 0.00 -2,601 69.35 O 0 O 0.00 228 -6.08 O 0.00 -172 4.59 0 0.00 -404 10.77 O 0.00 0 0.00 -3,751 100.00 Main Clg Aux Clg Opt Vent Total Total Capacity ton MBh 0.6 7.4 0.0 0.0 0.0 0.0 0.6 7.4 COOLING COIL SELECTION Sens Cap. Coil Airflow Enter DB/WB /HR MBh cfm °F °F gr/lb 5.5 214 78.6 63.2 63.4 0.0 0 0.0 0.0 0.0 0.0 0 0.0 0.0 0.0 Leave DB/WB /HR °F °F gr/lb 54.5 51.2 51.8 0.0 0.0 0.0 0.0 0.0 0.0 Project Name: Dataset Name: 7317040 Group Health AMB Pharmacy GH1.TRC AREAS Gross Total Glass ft ( %) Floor 191 Part 0 Int Door 0 ExFIr 0 Roof 191 Wall 0 Ext Door 0 0 0 O 0 O 0 TEMPERATURES Cooling Heating 55.0 71.0 77.5 66.0 77.5 66.0 78.6 32.8 0.1 0.0 0.1 0.0 0.4 0.0 SADB Ra Plenum Return Ret/OA Fn MtrTD Fn BIdTD Fn Frict AIRFLOWS Cooling 217 217 217 217 0 0 0 65 217 0 0 0 0 0 Diffuser Terminal Main Fan Sec Fan Nom Vent AHU Vent Infil MinStop /Rh Return Exhaust Rm Exh Auxiliary Leakage Dwn Leakage Ups Heating 217 217 65 217 51 51 0 65 65 51 0 0 0 0 ENGINEERING CKS OA cfm/ft' cfm/ton ff /ton Btu/hr•ft' No. People Cooling 23.7 1.14 351.51 309.54 38.77 8 Heating 23.7 1.14 -19.64 HEATING COIL SELECTION Capacity Coil Airflow Ent MBh cfm °F Main Htg Aux Htg Preheat Humidif Opt Vent Total -2.0 0.0 -1.7 Lvg °F 217 62.5 71.0 0 0.0 0.0 51 24.0 54.5 0.0 0 0.0 0.0 0.0 0 0.0 0.0 -3.8 TRACE® 700 v6.2.6.5 calculated at 08:53 AM on 11/28/2011 Alternative - 1 System Checksums Report Page 21 of 25 Room Checksums By MMFS 222 Reception /Copy COOLING COIL PEAK Peaked at Time: Outside Air: Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass /Door Cond Wall Cond Partition /Door Floor Adjacent Floor Infiltration Sub Total = => Internal Loads Lights People Misc Sub Total = => Ceiling Load Ventilation Load Adj Air Trans Heat Dehumid. Ov Sizing Ov /Undr Sizing Exhaust Heat Sup. Fan Heat Rat. Fan Heat Duct Heat Pkup Underfir Sup Ht Pkup Supply Air Leakage Grand Total = => Mo /Hr:7/16 OADB/WB /HR: 81 / 65 / 68 Space Plenum Sens. + Lat. Sens. + Lat Btu /h Btu /h 0 0 0 0 0 0 0 0 0 0 0 1.952 1,350 5.486 8,789 Net Total Btu /h O 0 O 0 1.666 1.666 O 0 O 0 0 0 0 0 0 0 0 1.666 1.666 488 2.440 O 1,350 O 5,486 488 9,277 638 -638 0 0 0 688 0 0 0 0 0 -179 -179 238 O 0 O 0 0 0 0 Percent Of Total ( %) CLG SPACE PEAK Mo /Hr: 7 / 20 OADB: 73 Space Sensible Btu /h Percent Of Total (%) 0 0 0 0 0 0 14 0 0 0 0 0 0 0 0 0 0 0 O 0 0 O 0 0 0 0 0 O 0 0 14 0 0 21 1,952 22 12 750 8 47 5,486 61 79 • 8,189 91 0 6 0 0 0 -2 2 0 0 0 0 9,426 1,337 11.690 100.00 776 9 0 0 0 0 0 0 8,964 Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass /Door Cond Wall Cond Partition /Door Floor Adjacent Floor Infiltration Sub Total = => Internal Loads Lights People Misc Sub Total = => Ceiling Load Ventilation Load Adj Air Trans Heat Ov /Undr Sizing Exhaust Heat OA Preheat M. RA Preheat Duff. Additional Reheat System Plenum Heat Underfir Sup Ht Pkup Supply Air Leakage 100.00 Grand Total = => HEATING COIL PEAK Mo /Hr. Heating Design OADB: 24 Space Peak Coil Peak Space Sens Tot Sens Btu /h Btu /h 0 0 0 0 0 -3.001 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 -3,001 0 0 0 0 -914 0 0 0 -914 Percent Of Total (%) 0.00 0.00 48.34 0.00 0.00 0.00 0.00 0.00 0.00 0.00 48.34 O 0.00 O 0.00 O 0.00 0 0.00 0 -2,927 0 0 257 0 -815 0 278 0 0 0.00 47.15 0 0.00 -4.13 0.00 13.13 0.00 -4.48 0.00 0.00 -6,207 100.00 Main CIg Aux CIg Opt Vent Total Total Capacity ton MBh 1.0 11.7 0.0 0.0 0.0 0.0 1.0 11.7 COOLING COIL SELECTION Sens Cap. Coil Airflow Enter DB/WB /HR MBh cfm °F °F gr/Ib 10.8 402 78.3 62.8 62.0 0.0 0 0.0 0.0 0.0 0.0 0 0.0 0.0 0.0 Leave DB/WBIHR °F °F gr/lb 54.5 52.8 57.8 0.0 0.0 0.0 0.0 0.0 0.0 Project Name: Dataset Name: 7317040 Group Health AMB Pharmacy GH1.TRC AREAS Gross Total Glass ft' li) Floor 715 Part 0 Int Door 0 ExFIr 0 Roof 715 Wall 0 Ext Door 0 0 0 0 0 0 0 TEMPERATURES Cooling Heating 55.0 72.0 77.8 66.0 77.8 66.0 78.3 46.1 0.1 0.0 0.1 0.0 0.4 0.0 SADB Ra Plenum Return RetlOA Fn MtrTD Fn BIdTD Fn Frict AIRFLOWS Cooling 408 408 408 408 0 0 0 122 408 0 0 0 0 0 Diffuser Terminal Main Fan Sec Fan Nom Vent AHU Vent Infil MinStop/Rh Return Exhaust Rm Exh Auxiliary Leakage Dwn Leakage Ups Heating 408 408 122 408 58 58 0 122 122 58 0 0 0 0 ENGINEERING CKS OA cfm/ft' cfm/ton ft' /ton Btu/hr•ft' No. People Cooling 14.2 0.57 418.74 733.99 16.35 3 Heating 14.2 0.57 -8.68 HEATING COIL SELECTION Capacity Coil Airflow Ent MBh cfm °F Main Htg Aux Htg Preheat Humidif Opt Vent Total -4.3 0.0 -1.9 Lvg °F 408 62.5 72.0 0 0.0 0.0 58 24.0 54.5 0.0 0 0.0 0.0 0.0 0 0.0 0.0 -6.2 TRACE® 700 v6.2.6.5 calculated at 08:53 AM on 11/28/2011 Alternative - 1 System Checksums Report Page 22 of 25 Room Checksums By MMFS 223 Conference COOLING COIL PEAK Peaked at Time: Mo /Hr: 7 / 14 Outside Air: OADB/WB /HR: 81 / 66 / 74 Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass /Door Cond Wall Cond Partition /Door Floor Adjacent Floor Infiltration Sub Total = => Internal Loads Lights People Misc Sub Total = => Ceiling Load Ventilation Load Adj Air Trans Heat Dehumid. Ov Sizing Ov /Undr Sizing Exhaust Heat Sup. Fan Heat Ret. Fan Heat Duct Heat Pkup Underflr Sup Ht Pkup Supply Air Leakage Grand Total = => Space Plenum Sens. + Lat. Sens. + Lat Btu /h Btu /h O 0 O o O 197 o 0 0 0 O 0 0 0 0 0 0 0 197 Net Percent Total Of Total Btu /h ( %) O 0 o o 197 3 o 0 0 0 O 0 O 0 0 0 o o 0 0 197 3 333 83 416 7 2,700 0 2,700 46 1,920 0 1,920 33 4,953 83 5,037 86 85 -85 0 0 0 0 595 10 O 0 0 0 0 0 0 0 -90 -90 -2 104 2 0 0 0 0 0 0 0 0 0 0 0 5,038 105 5,841 100.00 CLG SPACE PEAK Mo /Hr: 7 / 20 OADB: 73 Space Sensible Btu /h Percent Of Total ( %) Envelope Loads O 0 Skylite Solar 0 0 Skylite Cond D 0 Roof Cond 0 0 Glass Solar 0 0 Glass /Door Cond 0 0 Wall Cond 0 0 Partition/Door 0 0 Floor 0 0 Adjacent Floor O 0 Infiltration 0 0 Sub Total = => 333 1,500 1,920 3,753 Internal Loads 9 Lights 39 People 49 Misc 97 Sub Total = => 132 3 Ceiling Load 0 0 Ventilation Load 0 0 Adj Air Trans Heat Ov /Undr Sizing 0 0 Exhaust Heat OA Preheat Diff. RA Preheat Diff. Additional Reheat System Plenum Heat Underflr Sup Ht Pkup Supply Air Leakage 3,886 100.00 Grand Total = => HEATING COIL PEAK Mo /Hr: Heating Design OADB: 24 Space Peak Space Sens Btu /h 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 -156 0 0 0 -156 Coil Peak Percent Tot Sens Of Total Btu /h ( %) 0 0.00 0 0.00 -512 17.90 0 0.00 0 0.00 0 0.00 0 0.00 0 0.00 0 0.00 0 0.00 -512 17.90 0 0.00 0 0.00 0 0.00 0 0.00 0 0.00 -1,886 65.97 0 0 0 0.00 165 -5.79 0 0.00 -199 6.95 0 0.00 -428 14.96 0 0.00 0 0.00 -2,859 100.00 Main Clg Aux Clg Opt Vent Total Total Capacity ton MBh 0.5 5.8 0.0 0.0 0.0 0.0 0.5 5.8 COOLING COIL SELECTION Sens Cap. Coil Airflow Enter DBIWB /HR MBh cfm °F °F gr/lb 4.3 175 78.1 63.1 0.0 0 0.0 0.0 63.8 0.0 0.0 0 0.0 0.0 0.0 Leave DB/WB /HR °F °F gr/lb 54.5 51.5 53.0 0.0 0.0 0.0 0.0 0.0 0.0 Project Name: Dataset Name: 7317040 Group Health AMB Pharmacy GHI.TRC AREAS Gross Total Glass ft' ( %) Floor 122 Part 0 Int Door 0 ExFlr 0 Roof 122 Wall 0 Ext Door 0 0 0 0 0 0 0 TEMPERATURES Cooling Heating 55.0 70.8 77.2 66.0 77.2 66.0 78.1 36.4 0.1 0.0 0.1 0.0 0.4 0.0 SADB Ra Plenum Return Ret/OA Fn MtrTD Fn BIdTD Fn Frict AIRFLOWS Cooling 177 177 177 177 0 0 0 53 177 0 0 0 0 0 Diffuser Terminal Main Fan Sec Fan Nom Vent AHU Vent Infil MinStop /Rh Return Exhaust Rm Exh Auxiliary Leakage Dwn Leakage Ups Heating 177 177 53 177 37 37 0 53 53 37 0 0 0 0 ENGINEERING CKS OA cfmlfe cfm /ton tenon Btu /heft' No. People Cooling 21.1 1.45 363.22 250.63 47.88 6 Heating 21.1 1.45 -23.44 HEATING COIL SELECTION Capacity Coil Airflow Ent MBh cfm °F Main Htg Aux Htg Preheat Humidif Opt Vent Total -1.6 0.0 -1.3 Lvg °F 177 62.5 70.8 0 0.0 0.0 37 24.0 54.5 0.0 0 0.0 0.0 0.0 0 0.0 0.0 -2.9 TRACE® 700 v6.2.6.5 calculated at 08:53 AM on 11/28/2011 Alternative - 1 System Checksums Report Page 23 of 25 Room Checksums By MMFS 224 Conference COOLING COIL PEAK CLG SPACE PEAK Peaked at Time: Outside Air: Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass /Door Cond Wall Cond Partition /Door Floor Adjacent Floor Infiltration Sub Total = => Internal Loads Lights People Misc Sub Total = => Ceiling Load Ventilation Load Adj Air Trans Heat Dehumid. Ov Sizing Ov /Undr Sizing Exhaust Heat Sup. Fan Heat Ret. Fan Heat Duct Heat Pkup Underflr Sup Ht Pkup Supply Air Leakage Grand Total = => Mo /Hr: 7 / 14 OADB/WB /HR: 81 / 66 / 74 Space Plenum Sens. + Lat. Sens. + Lat Btu /h Btu /h 0 0 0 0 0 0 0 0 0 0 0 0 0 194 0 0 0 0 194 Net Total Btu /h 0 0 194 0 0 0 0 0 0 0 194 Percent Of Total ( %) 0 0 3 0 0 0 0 0 0 0 3 Mo /Hr: 7 / 20 OADB: 73 Space Sensible Btu /h 0 0 0 0 0 0 0 0 0 0 0 Percent Of Total ( %) Envelope Loads 0 Skylite Solar O Skylite Cond O Roof Cond O Glass Solar O Glass /Door Cond 0 Wall Cond O Partition/Door O Floor 0 • Adjacent Floor 0 Infiltration O Sub Total = => 328 82 410 7 328 8 2,700 0 2,700 46 1,500 39 1,917 0 1,917 33 1,917 49 4,944 82 5.026 86 3,744 97 84 0 0 0 5,028 -84 0 -90 0 0 0 102 0 593 0 0 0 -90 103 0 0 0 0 0 10 0 0 0. -2 2. 0 0 0 0 5,826 100.00 130 3 0 0 0 0 0 0 Internal Loads Lights People Misc Sub Total = => Ceiling Load Ventilation Load Adj Air Trans Heat Ov /Undr Sizing Exhaust Heat OA Preheat Diff. RA Preheat Diff. Additional Reheat System Plenum Heat Underflr Sup Ht Pkup Supply Air Leakage 3,875 100.00 Grand Total = => HEATING COIL PEAK Mo /Hr: Heating Design OADB: 24 Space Peak Coil Peak Space Sens Tot Sens Btu /h Btu /h O 0 0 0 O -504 O 0 O 0 0 0 0 0 0 0 O 0 O 0 0 -504 0 0 0 0 -153 0 0 0 -153 Percent Of Total I%) 0.00 0.00 17.68 0.00 0.00 0.00 0.00 0.00 0.00 0.00 17.68 O 0.00 O 0.00 O 0.00 O 0.00 0 -1,880 0 0 165 0 -198 0 -431 0 0 0.00 66.01 0 0.00 -5.79 0.00 6.96 0.00 15.14 0.00 0.00 -2,849 100.00 Main Clg Aux Clg Opt Vent Total Total Capacity ton MBh 0.5 5.8 0.0 0.0 0.0 0.0 0.5 5.8 COOLING COIL SELECTION Sens Cap. Coil Airflow Enter DB/WB /HR MBh cfm °F °F gr/lb 4.3 174 78.1 63.1 0.0 0 0.0 0.0 0.0 0 0.0 0.0 63.8 Leave DBNVB /HR °F °F gr/lb 54.5 51.5 53.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 Project Name: Dataset Name: 7317040 Group Health AMB Pharmacy GH1.TRC AREAS Gross Total Glass ft ( %) Floor 120 Part 0 Int Door 0 ExFlr 0 Roof 120 Wall 0 Ext Door 0 O 0 O 0 O 0 TEMPERATURES Cooling Heating 55.0 70.8 77.2 66.0 77.2 66.0 78.1 36.5 0.1 0.0 0.1 0.0 0.4 0.0 SADB Ra Plenum Return Ret/OA Fn MtrTD Fn BIdTD Fn Frict AIRFLOWS Cooling 176 176 176 176 0 0 0 53 176 0 0 0 0 0 Diffuser Terminal Main Fan Sec Fan Nom Vent AHU Vent Infil MinStoplRh Return Exhaust Rm Exh Auxiliary Leakage Dwn Leakage Ups Heating 176 176 53 176 37 37 a 53 53 37 0 0 0 0 ENGINEERING CKS OA cfm/ft' cfm/ton ft'/ton Btu/hi-ft' No. People Cooling 21.1 1.47 363.15 247.17 48.55 6 Heating 21.1 1.47 -23.74 HEATING COIL SELECTION Capacity Coil Airflow Ent MBh cfm °F Main Htg Aux Htg Preheat Humldif Opt Vent Total -1.6 0.0 Lvg °F 176 62.5 70.8 0 0.0 0.0 -1.3 37 24.0 54.5 0.0 0 0.0 0.0 0.0 0 0.0 0.0 -2.9 TRACE® 700 v6.2.6.5 calculated at 08:53 AM on 11/28/2011 Alternative - 1 System Checksums Report Page 24 of 25 Room Checksums By MMFS 225 Interior Office COOLING COIL PEAK Peaked at Time: Mo /Hr: 7 / 15 Outside Air: OADB/WB /HR: 82 / 66 / 71 Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass /Door Cond Wall Cond Partition /Door Floor Adjacent Floor Infiltration Sub Total = => Internal Loads Lights People Misc Sub Total = => Ceiling Load Ventilation Load Adj Air Trans Heat Dehumid. Ov Sizing Ov /Undr Sizing Exhaust Heat Sup. Fan Heat Ret Fan Heat Duct Heat Pkup Underflr Sup Ht Pkup Supply Air Leakage Grand Total = => Space Plenum Sens. + Lat. Sens. + Lat Btu /h Btu /h 0 0 0 0 0 1,650 0 0 0 0 0 0 0 0 0 0 0 0 1,650 CLG SPACE PEAK Mo /Hr: 7 / 20 OADB: 73 Net Percent Space Percent Total Of Total Sensible Of Total Btu /h ( %) Btu /h ( %) 0 0 0 0 0 0 0 0 1,650 8 0 0 0 0 0 0 0 0 0 0 O 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 O 0 0 0 1,650 8 0 0 2.277 569 2,846 14 2,277 16 5,850 0 5.850 29 3,250 22 8.079 0 8.079 40 8,079 56 16,206 569 16.775 83 13,606 94 664 -664 0 0 905 6 O 0 1,681 8 0 0 O 0 0 0 0 0 0 O 0 0 0 0 -318 -318 -2 385 2 O 0 0 O 0 0 O 0 O 0 0 Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass /Door Cond Wall Cond Partition /Door Floor Adjacent Floor Infiltration Sub Total = => Internal Loads Lights People Misc Sub Total = => Ceiling Load Ventilation Load Adj Air Trans Heat Ov /Undr Sizing Exhaust Heat OA Preheat Diff. RA Preheat Diff. Additional Reheat System Plenum Heat Underflr Sup Ht Pkup Supply Air Leakage 16,870 1.237 20,173 100.00 14,511 100.00 Grand Total = => HEATING COIL PEAK Mo /Hr: Heating Design OADB: 24 Space Peak Coil Peak Space Sens Tot Sens Btu /h Btu /h O 0 O 0 O -3,500 O 0 O 0 O 0 O 0 O 0 O 0 0 0 0 -3,500 0 0 0 0 -1,066 0 0 0 -1,066 0 0 0 Percent Of Total (%) 0.00 0.00 33.82 0.00 0.00 0.00 0.00 0.00 0.00 0.00 33.82 0.00 0.00 0.00 0 0.00 0 -5,815 0 0 510 0 -1,050 0 -493 0 0 0.00 56.19 0 0.00 -4.93 0.00 10.15 0.00 4.76 0.00 0.00 - 10,348 100.00 Main Clg Aux Clg Opt Vent Total Total Capacity ton MBh 1.7 20.2 0.0 0.0 0.0 0.0 1.7 20.2 COOLING COIL SELECTION Sens Cap. Coil Airflow Enter DB/WB /HR MBh cfm °F °F gr/lb 16.8 649 78.3 63.0 62.8 0.0 0 0.0 0.0 0.0 Leave DBIWB /HR °F °F grub 54.5 52.3 55.7 0.0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Project Name: Dataset Name: 7317040 Group Health AMB Pharmacy GH 1.TRC AREAS Gross Total Glass Floor 834 Part 0 Int Door 0 ExFlr 0 Roof 834 Wall 0 Ext Door 0 fH (14) O 0 0 0 0 0 TEMPERATURES Cooling Heating 55.0 71.5 77.5 66.0 77.5 66.0 78.3 41.6 0.1 0.0 0.1 0.0 0.4 0.0 SADB Ra Plenum Return Ret/OA Fn MtrTD Fn BIdTD Fn Frict AIRFLOWS Cooling 660 660 660 660 0 0 0 198 660 0 0 0 0 0 Diffuser Terminal Main Fan Sec Fan Nom Vent AHU Vent Infil MinStoplRh Return Exhaust Rm Exh Auxiliary Leakage Dwn Leakage Ups Heating 660 660 198 660 115 115 0 198 198 115 0 0 0 0 ENGINEERING CKS OA cfm/ft cfm/ton ft'lton Btu/hr-ft' No. People Cooling 17.4 0.79 392.77 496.11 24.19 13 Heating 17.4 0.79 -12.41 HEATING COIL SELECTION Capacity Coil Airflow Ent MBh cfm °F Main Htg Aux Htg Preheat Humidif Opt Vent Total -6.5 0.0 -3.9 Lvg °F 660 62.5 71.5 0 0.0 0.0 115 24.0 54.5 0.0 0 0.0 0.0 0.0 0 0.0 0.0 -10.4 TRACE® 700 v6.2.6.5 calculated at 08:53 AM on 11/28/2011 Alternative - 1 System Checksums Report Page 25 of 25 Load / Airflow Summary By MMFS Coil Coil Space VAV Main Coil Heating Floor Cooling Cooling Design Air Minimum VAV Heating Fan Percent Area People Sensible Total Max SA Changes SA Minimum Sensible Max SA OA System Zone Room " fY # Btu/h BtWh cfm ach /hr cfm °h Btulh efm Clg Iternativel•. , :. sr . �e#`*" °:' '` "a.� �. � -� � ��' ? -._ . _. .: �� ar �_�,. s . � .. ._ ,�. -. � ..�� ,� ._ 202 Office Zone - 011 Zone - 011 203 Conference Zone -012 Zone - 012 204 Conference Zone -013 Zone -013 205 Workstations 206 Office 207 Office 208 Work Area Zone -014 Zone -014 209 Office 210 Office 211 Office 212 Office 215 Hall Zone -015 Rm Peak 121 1.0 1,953 2,294 73 4.53 22 30 -1,908 51 16.8 Zn Peak 121 1.0 1,953 2,294 73 30 -1,908 51 16.8 Zn Block 121 1.0 1,953 2,294 73 30 -1,908 51 16.8 Rm Peak 121 6.0 4,592 6,106 185 11.44 55 30 -2,825 129 20.2 Zn Peak 121 6.0 4,592 6,106 185 30 -2,825 129 20.2 Zn Block 121 6.0 4,592 6,106 185 30 -2,825 129 20.2 Rm Peak 121 6.0 4,592 6,106 185 11.44 55 30 -2,825 129 20.2 Zn Peak 121 6.0 4,592 6,106 185 30 -2,825 129 20.2 Zn Block 121 6.0 4,592 6,106 185 30 -2,825 129 20.2 Rm Peak 414 8.0 10,518 12,601 414 7.50 124 30 -8,203 290 15.7 Rm Peak 77 1.0 1,573 1,876 60 5.89 18 30 -1,415 42 15.9 Rm Peak 67 1.0 1,479 1,772 57 6.41 17 30 -1,281 40 15.8 Rm Peak 97 1.0 1,763 2,083 67 5.16 20 30 -1,684 47 16.2 Zn Peak 655 11.0 15,333 18,332 598 30 - 12,584 419 15.8 Zn Block 655 11.0 15,333 18,332 598 30 - 12,584 419 15.8 Rm Peak 100 1.0 2,144 2,481 80 5.98 24 30 -2,125 56 13.8 Rm Peak 79 1.0 1,800 2,117 69 6.55 21 30 -1,501 48 14.1 Rm Peak 76 1.0 1,779 2,093 68 6.74 20 30 -1,473 48 14.0 Rm Peak 78 1.0 1,793 2,109 69 6.62 21 30 -1,491 48 14.1 Rm Peak 180 0.0 1,498 1,498 45 1.88 14 30 -602 32 0.0 Zn Peak 513 4.0 9,157 10,441 331 30 -7,193 232 15.5 Zone - 015 Zn Block 513 4.0 8,727 10,095 331 30 -7,193 232 15.5 216 Interior Office Rm Peak 871 9.0 14,039 16,311 531 4.57 159 30 -5,480 372 18.3 Zone -016 Zn Peak 871 9.0 14,039 16,311 531 30 -5,480 372 18.3 Zone -016 Zn Block 871 9.0 14,039 16,311 531 30 -5,480 372 18.3 217 Interior Office Rm Peak 1,671 18.0 27,522 32,046 1,044 4.69 313 30 - 10,723 731 18.2 Zone -017 Zn Peak 1,671 18.0 27,522 32,046 1,044 30 - 10,723 731 18.2 Zone -017 Zn Block 1,671 18.0 27,522 32,046 1,044 30 - 10,723 731 18.2 218 Interior Office Rm Peak 1,671 18.0 29,923 34,840 1,168 5.24 350 30 - 11,745 818 16.3 Zone -018 Zn Peak 1,671 18.0 29,923 34,840 1,168 30 - 11,745 818 16.3 Zone -018 Zn Block 1,671 18.0 29,923 34,840 1,168 30 - 11,745 818 16.3 201 Entry Rm Peak 98 0.0 967 1,027 31 2.40 9 30 -1,326 22 18.8 220 Interior Office Rm Peak 825 5.0 10,780 11,780 381 3.46 114 30 -4,186 266 0.0 221 Conference Rm Peak 191 8.0 5,448 7,404 217 8.52 65 30 -2,028 152 23.7 222 Reception /Copy Rm Peak 715 3.0 10,808 11,690 408 4.28 122 30 -4,269 286 14.2 This report does not display heating only systems. Project Name: Dataset Name: 7317040 Group Health AMB Pharmacy GH1.TRC Htg 16.8 16.8 16.8 20.2 20.2 20.2 20.2 20.2 20.2 15.7 15.9 15.8 16.2 15.8 15.8 13.8 14.1 14.0 14.1 23.9 15.3 15.3 18.3 18.3 18.3 18.2 18.2 18.2 16.3 16.3 16.3 18.8 19.6 23.7 14.2 TRACE® 700 v6.2.6.5 calculated at 08:53 AM on 11/28/2011 Load /Airflow Summary Report Page 1 of 2 s Coil Coil Space VAV Main Coil Heating Floor Cooling Cooling Design Air Minimum VAV Heating Fan Percent Area People Sensible Total Max SA Changes SA Minimum Sensible Max SA OA System Zone Room " ft' # Btulh Btulh cfm ach/hr cfm Y Btulh cfm Clg Htg Zone -019 Zn Peak 1,829 16.0 28,749 32,647 1,037 30 - 11,809 726 18.3 18.3 Zone - 019 Zn Block 1,829 16.0 27,711 31,863 1,037 30 - 11,809 726 18.3 18.3 223 Conference Rm Peak 122 6.0 4,309 5,841 177 10.87 53 30 -1,610 124 21.1 21.1 Zone - 020 Zn Peak 122 6.0 4,309 5,841 177 30 -1,610 124 21.1 21.1 Zone - 020 Zn Block 122 6.0 4,309 5,841 177 30 -1,610 124 21.1 21.1 224 Conference Rm Peak 120 6.0 4,295 5,826 176 11.02 53 30 -1,604 123 21.1 21.1 Zone - 021 Zn Peak 120 6.0 4,295 5,826 176 30 -1,604 123 21.1 21.1 Zone - 021 Zn Block 120 6.0 4,295 5,826 176 30 -1,604 123 21.1 21.1 225 Interior Office Rm Peak 834 13.0 16,777 20,173 660 5.94 198 30 -6,497 462 17.4 17.4 Zone - 022 Zn Peak 834 13.0 16,777 20,173 660 30 -6,497 462 17.4 17.4 Zone - 022 Zn Block 834 13.0 16,777 20,173 660 30 -6,497 462 17.4 17.4 213 Workstations Rm Peak 444 8.0 11,101 13,395 441 7.44 132 30 -8,160 308 15.1 15.1 Zone -023 Zn Peak 444 8.0 11,101 13,395 441 30 -8,160 308 15.1 15.1 Zone -023 Zn Block 444 8.0 11,101 13,395 441 30 -8,160 308 15.1 15.1 214 Interior Office Rm Peak 1,150 12.0 18,630 21,656 705 4.60 212 30 -7,269 494 18.3 18.3 Zone -024 Zn Peak 1,150 12.0 18,630 21,656 705 30 -7,269 494 18.3 18.3 Zone -024 Zn Block 1,150 12.0 18,630 21,656 705 30 -7,269 494 18.3 18.3 219 Conference Rm Peak 235 12.0 6,905 9,818 273 8.73 82 30 -2,550 191 27.1 27.1 Zone -025 Zn Peak 235 12.0 6,905 9,818 273 30 -2,550 191 27.1 27.1 Zone - 025 Zn Block 235 12.0 6,905 9,818 273 30 -2,550 191 27.1 27.1 System - 001 Sys Peak 10,478 146.0 199,417 237,370 7,584 - 94,782 5,309 18.1 17.9 System - 001 Sys Block 10,478 146.0 194,937 234,094 7,584 - 94,782 5,309 18.1 17.9 • This report does not display heating only systems. Project Name: Dataset Name: 7317040 Group Health AMB Pharmacy TRACE® 700 v6.2.6.5 calculated at 08:53 AM on 11/28/2011 GH1.TRC Load/Airflow Summary Report Page 2 of 2 °PERMIT COORD COP? PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M11 -180 DATE: 12/22/11 PROJECT NAME: GROUP HEALTH - AMB PHARMACY SITE ADDRESS: 12501 EAST MARGINAL WY S X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DnEPARTMENTS� �n Building Division i r e tPC Structural ❑ Public Works Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete n DUE DATE: 12/27/11 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required n REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: DUE DATE: 01/24/12 Approved Approved with Conditions Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 Contractors or Tradespeople Peter Friendly Page • Page 1 of 2 General /Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name MACDONALD /MILLER FAC SOL INC UBI No. 602254260 Phone 2067684180 Status Active Address Po Box 47983 License No. MACDOFS980RU Suite /Apt. License Type Construction Contractor City Seattle Effective Date 12/31/2002 State WA Expiration Date 12/31/2012 Zip 98106 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status DIVCOI *988RC DIVCO INCORPORATION Construction Contractor General Unused 12/3/2002 11/7/2012 Active LINFOAR980QG LINFORD AIR It REFRIGERTN INC Construction Contractor General Unused 11/7/2002 11/7/2004 Archived ENCOMMS984CA ENCOMPASS MECHANICAL SERVICES Construction Contractor General Unused 2/1/2002 2/1/2004 Archived MACDOMR026RU MACDONALD MILLER RSDNTL INC Construction Contractor General Unused 12/31/1998 12/31/2001 Archived DIVCOI*031L4 DIVCO INC Construction Contractor General Unused 6/24/1997 8/1/2003 Archived MACDOMR0760P MACDONALD MILLER RESIDENTIAL L Construction Contractor General Unused 9/17/1993 12/30/1998 Archived DIVCOEC188LC DIVCO ENERGY CONTROL COMPANY Construction Contractor General Unused 6/3/1982 5/26/1997 Archived MACDOM*248J9 MACDONALD MILLER CO Construction Contractor General Unused 4/29/1976 2/1/2002 Archived Business Owner Information Name Role Effective Date Expiration Date GOUGH, DAVID ANTHONY Director 12/29/2010 HOEL, STEPHANIE W Member 05/14/2010 SIMONDS, DERRICK R President 05/14/2010 WEBSTER, MARK E Vice President 05/14/2010 https://fortress.wa.gov/lni/bbip/Print.aspx 01/06/2012 J: \731 \7040 GH AMB Pharmacy Administration RC \00 \Eng \Dwg \S December 21, 2011 11:00:46 AM ABBV FULL NAME ABBV FULL NAME A AC AFF AL BDD BOB BOD BOTT BTU BTUH BWG BWR C CAP CC CFM CHWR CHWS COMB CONN CWR CWS DB DIFF DMPR DN EC EGC EER ELEV EMS COMPRESSED AIR LINE AIR CONDITIONING UNIT ABOVE FINISHED FLOOR ALUMINUM BACKDRAFT DAMPER BOTTOM OF BEAM BOTTOM OF DUCT BOTTOM BRITISH THERMAL UNITS BRITISH THERMAL UNITS PER HOUR BOTTOM WALL GRILLE BOTTOM WALL REGISTER CONDENSATE CAPACITY CONTROLS CONTRACTOR CUBIC FEET PER MINUTE CHILLED WATER RETURN CHILLED WATER SUPPLY COMBUSTION CONNECT CONDENSER WATER RETURN CONDENSER WATER SUPPLY DUCT BOARD DIFFUSER DAMPER DOWN ELECTRICAL CONTRACTOR EGGCRATE ENERGY EFFICIENCY RATIO ELEVATION ENERGY MANAGEMENT SYSTEM ESP EXH EXTR FAC FD FLA FOB FOT FSD G GALV GC GPM GR GWB HG HP HWR HWS ID INT LIQ M -M MBH MC MCA MD MIN MT MUA NOM EXTERNAL STATIC PRESSURE EXHAUST EXTRACTOR FIRE ALARM CONTRACTOR FIRE DAMPER FULL LOAD AMPS FLAT ON BOTTOM FLAT ON TOP FIRE SMOKE DAMPER GAS LINE GALVANIZED GENERAL CONTRACTOR GALLONS PER MINUTE GRILLE GYPSUM WALL BOARD HOT GAS LINE HORSE POWER HOT WATER RETURN HOT WATER SUPPLY INSIDE DIMENSION INTERLOCK LIQUID LINE MACDONALD- MILLER ONE THOUSAND BTUH MECHANICAL CONTRACTOR MINIMUM CIRCUIT AMPACITY MOTORIZED DAMPER MINIMUM MOUNT MAKE -UP AIR NOMINAL ABBV OSA OBD OD RA REG REQ'D RIO SA SCD SD SL SM SP SS SSSC STL SUC SUSP T'STAT TC TOD TOS TV TWG TWR TYP UNO VD VFD 0 FULL NAME OUTSIDE AIR OPPOSED BLADE DAMPER OUTSIDE DIMENSION RETURN AIR REGISTER (GRILLE WITH DAMPER) REQUIRED ROUGH IN ONLY SUPPLY AIR SMOKE CONTROL DAMPER SMOKE DAMPER SOUND LINING SHEET METAL STATIC PRESSURE START /STOP SOLID STATE SPEED CONTROLLER STEEL SUCTION LINE SUSPENDED THERMOSTAT TEMPERATURE CONTROL TOP OF DUCT TOP OF STEEL TURN VANES TOP WALL GRILLE TOP WALL REGISTER TYPICAL UNLESS NOTED OTHERWISE VOLUME DAMPER VARIABLE FREQUENCY DRIVE VOLTAGE PHASE & DUCT DIAMETER FILE COPY P It No. li0 . Ram mew approval is to errors and omissions. Approval of construction documents does not authorize trig v o ation of any a code or ordinance. Receipt of opproved Field Copy and s is acknowledged: By .�.. D , ,_'/10 //2 1 City Of lbkwila BUILDING DIVISION DESCRIPTION SYMBOL DESCRIPTION SYMBOL BARE SHEETMETAL 14x12 ROUND SHEETMETAL WRAPPED W/ INSULATION (2 ") 120W SOUNDLINE SHEETMETAL (1" LINING) 14x12SL CLEANROOM QUALITY DUCTWORK 14x12C SHEETMETAL WRAPPED W/ INSULATION (2 ") 14x12W BARE FLAT OVAL SHEETMETAL 14x120 BARE ROUND SHEETMETAL 120 FLAT OVAL FLAT SHEETMETAL W/ INSULATION (2') 14x120W EXPOSED QUALITY SHEETMETAL 14x12Q DUCTBOARD (1" FIBERGLASS) 14x12DB EXAMPLE OF NEW 14x12 EXAMPLE OF NOT IN CONTRACT (NIC) 14x12 EXAMPLE OF DEMO FLEX DUCT EXAMPLE OF EXISTING 14X12 FLEX CONNECTOR FFUSERIGRII SYMBOL MANUFACTURER & MODEL NUMBER SIZE TYPE NOTES CFM BUILDING STANDARD AS NOTED T -BAR LAY -IN MODULAR CORE DIFFUSER MATCH EXISTING DIFFUSERS M -M METAL EGGCRATE 12/24 RETURN /EXH M -M METAL EGGCRATE 24/24 RETURN /EXH OX PAR .t,L AND FLC�f3R SERI S 1/A'l/ �30X HE UL.E T l UNIT NO. MFG & MODEL NO. INLET SIZE FAN CFM VALVE CFM HEATER FAN NOTES MAX MIN KW DT CFM VOLT /PH STGS HP VOLT /PH SPD VAV -211 TEMPMASTER HFSL -A 5 275 165 145 1.5 17 275 277/1 - 277/1 EXISTING, 3 VAV -212 TEMPMASTER HFSL -A 5 275 165 145 1.5 17 275 277/1 - 277/1 EXISTING, 3 VAV -213 TEMPMASTER HFSL -A 5 275 165 145 1.5 17 275 277/1 - 277/1 EXISTING, 3 VAV -214 TEMPMASTER HFSL -E 10 870 640 140 8 29 870 460/3 - 277/1 EXISTING, 3, 4 VAV -215 TEMPMASTER HFSL -E 10 660 590 140 6 29 660 460/3 - 277/1 EXISTING, 3, 4 VAV -216 TEMPMASTER HFSL -F 12 940 855 220 9 30 940 460/3 - 277/1 EXISTING, 3, 4 VAV -217 TEMPMASTER HFSL -F 12 1200 1090 220 9 24 1200 460/3 - 277/1 EXISTING, 3, 4 VAV -218 TEMPMASTER HFSL -E 10 1215 1100 180 7 18 1215 460/3 - 277 /1 EXISTING, 3, 4 VAV -219 TEMPMASTER HFSL -E 10 1225 1110 570 7 18 1225 460/3 - 277/1 EXISTING, 3 VAV -220 TEMPMASTER HFSL -A 5 275 165 145 1.5 17 275 277/1 - 277/1 EXISTING, 3 VAV -221 TEMPMASTER HFSL -A 5 275 165 145 1.5 17 275 277/1 - 277/1 EXISTING, 3 VAV -222 TEMPMASTER HFSL -E 10 710 645 180 5.5 24 710 277/1 - 277 /1 EXISTING, 3, 4 VAV -223 ENVIROTEC CVFQ -0811E 8 490 440 150 4.5 29 490 277/1 2 1/3 277/1 VAR NEW, 1, 2, 4 VAV -224 ENVIROTEC CVFQ -0811E 8 780 705 240 4.0 16 780 277/1 1 1/3 277/1 VAR NEW, 1, 2, 4 VAV -225 ENVIROTEC CVFQ -0611E 6 300 275 100 1.5 16 300 277/1 1 1/3 277/1 VAR NEW, 1, 2, 4 NOTES: 1. DISCONNECT BY ELECTRICAL. 2. SERIES FAN POWERED TERMINAL UNIT WITH HEAT -, SIZE AS LISTED, PRESSURE INDEPENDENT, FACTORY OPTIONS INCLUDE: - ECM MOTOR - EXTENDED DAMPER 1/2" DIAM. SHAFT - FACTORY INSTALLED 1" THROW -AWAY FILTERS - CONTROLS BY OTHERS - FACTORY PROVIDE WIRING HARNESS WITH LOW VOLTAGE INTERLOCK CONDUCTORS EXTENDED FROM HIGH VOLTAGE CABINET TO LOW VOLTAGE CONTROLS CABINET. - 1" MATT -FACED UNIT INSULATION - VARIABLE SPEED FAN CONTROL - 24V TRANSFORMER, 50 VA MIN RATING SEPARATE PERMIT - HEAT STAGING & FAN CONTROL THROUGH FACTORY WIRED RELAYS REQUIRED FOR: - AUTO RESET 120 °F HIGH LIMIT T'STAT - NON MAGNETIC QUIET ACTING HEATER CONTACTOR 0 Mechanical 3. EXISTING SERIES FAN POWERED TERMINAL UNIT WITH HEAT -, SIZE AS LISTED. Electrical 4. AIR BALANCE..< plumbing i Gas Piping GENERAL NOTE: ALL HEATERS 5.9 KW AND SMALLER TO BE 277/1 VOLTAGE. HEATERS 6.0 KW AND LARGER TO BE 460/3 VOLTAGE. - ALL FAN MOTORS ARE 277/1 VOLTAGE, ALL TERMINALS ARE SINGLE POINT POWER CONNECTION. City of Tukwila BUILDING DIVISION NOTE TO ELECTRICAL: - 460V /3PH TERMINAL UNITS REQUIRE A FOUR WIRE POWER FEED IN ORDER TO SUPPLY 277V /1PH POWER TO THE FAN MOTOR. A VICINITY MAP NO SCALE . THESE PLANS ARE SCHEMATIC AND DO NOT SHOW EXACT ROUTING OR EVERY OFFSET WHICH MAY BE REQUIRED. THE HVAC CONTRACTOR IS TO COORDINATE WITH ALL OTHER TRADES AND IS TO VERIFY ALL CLEARANCES BEFORE COMMENCING WORK. 2. MATERIALS, METHODS, AND INSTALLATION SHALL COMPLY WITH THE PROVISIONS OF THE 2009 EDITIONS OF THE INTERNATIONAL MECHANICAL CODE, INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE AND STATE AND LOCAL CODES AND ORDINANCES. 3. DUCT CONSTRUCTION AND HANGING SHALL COMPLY WITH CHAPTER 6 OF THE 2009 IMC AND WITH CURRENT SMACNA STANDARDS. EARTHQUAKE BRACE ALL DUCTS 28" DIA AND LARGER WHICH ARE SUSPENDED MORE THAN 12" BELOW STRUCTURAL SYSTEM. 4. JOINTS OF MEDIUM AND HIGH VELOCITY DUCT SYSTEMS SHALL BE SEALED WITH GASKETS OR LISTED MASTIC TYPE DUCT SEALANT. 5. DUCTS SHALL BE INSULATED AS INDICATED ON PLANS, PER 2009 WSEC. - DUCT WRAP, WHERE INDICATED, SHALL BE 1 1/2" 0.75 LB /CU FT FIBERGLASS DUCT INSULATION WITH A FACTORY APPLIED REINFORCED ALUM. FOIL VAPOR BARRIER (R-4.2 MIN.). - SOUND LINING, WHERE INDICATED, SHALL BE 1" 1.5 LB /CU FT FIBERGLASS DUCT LINING COATED TO PREVENT FIBER EROSION AT VELOCITIES UP TO 6000 FPM (R-4.2 MIN.). - DUCT BOARD, WHERE INDICATED, SHALL BE 1" RIGID FRK FACED El 475 FIBERGLASS DUCT BOARD SYSTEM, UL 181 LISTED AS A CLASS 1 AIR DUCT (R-4.3 MIN.). AIR DUCT (R-4.3 MIN.). 6. FLEX DUCTS SHALL CONSIST OF A REINFORCED VAPOR BARRIER, 1 1/2" FIBERGLASS INSULATION, AND NON - PERFORATED INTERIOR LINER WITH WIRE HELIX. DUCT SHALL BE A UL 181 LISTED CLASS 1 AIR DUCT. FLEX DUCTS SHALL ONLY BE USED WHERE SHOWN AND SHALL NOT EXCEED 12' IN LENGTH UNLESS NOTED OTHERWISE. 7. PROVIDE EARTHQUAKE RESTRAINT FOR HVAC EQUIPMENT IN ACCORDANCE WITH SECTION 1613 OF THE 2009 IBC. a. PROVIDE FIRE DAMPERS, SMOKE DAMPERS AND FIRE/SMOKE DAMPERS WHERE INDICATED ON PLANS AND AS REQUIRED BY SECTION 716.5 OF THE 2009 IBC. PROVIDE CEILING FIRE DAMPERS WHERE INDICATED ON PLANS AND AS REQUIRED BY SECTION 716.6.2 OF THE 2009 IBC. INSTALL FIRE DAMPERS SMOKE DAMPERS AND FIRE/SMOKE DAMPERS IN ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS, THE TERMS OF THEIR LISTING, AND THE REQUIREMENTS OF THE CODE. 9. PIPING PENETRATIONS OF FIRE RATED WALLS OR FLOORS SHALL BE SLEEVED AND FIRE STOPPED WITH LISTED MATERIALS SO AS TO MAINTAIN THE INTEGRITY AND RATING OF THE FLOOR OR WALL. 10. PROVIDE RETURN DUCT SMOKE DETECTOR AUTOMATIC SHUT DOWN OF ALL NEW HEATING, COOLING, OR VENTILATION EQUIPMENT MOVING IN EXCESS OF 2000 CFM IN ACCORDANCE WITH SECTION 606 OF THE 2009 IMC. POWER AND INTERLOCK WIRING WITH THE BUILDING FIRE ALARM SYSTEM IS BY THE ELECTRICAL CONTRACTOR. 11. HVAC EQUIPMENT, VALVES AND DAMPERS SHALL BE LOCATED IN EASILY ACCESSIBLE LOCATIONS. UNLESS SHOWN ON ARCHITECTURAL DRAWINGS, REQUIRED ACCESS PANELS SHALL BE PROVIDED AND INSTALLED BY THE GENERAL CONTRACTOR. MINIMUM ACCESS DOOR SIZE FOR VALVES AND DAMPERS TO BE 18" X 18 ". 12. HEAT TRACING OF PIPING, WHERE INDICATED, SHALL BE PROVIDED AND INSTALLED BY THE HVAC CONTRACTOR. THE HVAC CONTRACTOR IS TO COORDINATE THE HEAT TRACE POWER WIRING WITH ELECTRICAL CONTRACTOR. 13. MOTORS STARTERS NOT LISTED AS BEING PROVIDED IN THE HVAC EQUIPMENT SCHEDULES ARE TO BE PROVIDED AND INSTALLED BY ELECTRICAL CONTRACTOR. REVI E NE CODE CUM APP RO a U .macmiller.com FOR R LIANCE ED JAN 3 '01 Cftyi of T 14. WITHIN 90 DAYS AFTER THE DATE OF SYSTEM ACCEPTANCE, RECORD DRAWINGS OF THE ACTUAL INSTALLATION TO BE PROVIDED TO THE BUILDING OWNER. RECORD DRAWING BUILDING SHALL INCLUDE AS A MINIMUM THE LOCATION AND PERFORMANCE DATA ON EACH PIECE OF EQUIPMENT, GENERAL CONFIGURATION OF DUCT AND PIPE DISTRIBUTION SYSTEM, INCLUDING SIZES, AND THE TERMINAL AIR AND WATER DESIGN FLOW RATES. 15. OPERATING AND MAINTENANCE MANUALS TO BE PROVIDED TO THE BUILDING OWNER THAT INCLUDE: SUBMITTAL DATA, NAMES AND ADDRESSES OF AT LEAST ONE SERVICE AGENCY, HVAC CONTROLS SYSTEM MAINTENANCE AND CALIBRATION INFORMATION AND A COMPLETE OPERATIONAL NARRATIVE FOR EACH SYSTEM. 16. COMMISSIONING IS REQUIRED ON THIS PROJECT IN ACCORD WITH WASHINGTON STATE ENERGY CODE (WSEC) SECTION 1416 AND WITH LEED NC -2.1 FUNDAMENTAL BUILDING SYSTEMS COMMISSIONING AND ADDITIONAL COMMISSIONING. 17. A COMPLETE REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND FILED WITH THE OWNER 18. FOR ALL "SEALED AIR TIGHT" SHAFTS OR ROOMS, THE FOLLOWING MUST OCCUR: - ALL VERTICAL JOINTS INSIDE THE SHAFT SHOULD BE PROVIDED WITH A CONTINUOUS SEAL FOR THE LENGTH OF THE JOINT, INCLUDING THE SHAFT CORNERS (BY GC). - TOP AND BOTTOM WALL TRACKS SHOULD BE CAULKED ALONG THEIR ENTIRE LENGTH (BY GC). - ANY FLOOR DECKING PERPENDICULAR TO THE SHAFT SHOULD BE CAULKED. FILLING WITH ROCK WOOL OR FIRESAFING ( "MONOCOAT ") IS NOT ACCEPTABLE (BY GC). - ANY PENETRATIONS OF THE SHAFT CONSTRUCTION (DUCTWORK, CONDUIT, PIPING) SHOULD BE SEALED WITH FIRE CAULKING ON BOTH SIDES OF THE PENETRATION. - USE SECTION 909.5 OF THE 2009 IBC FOR MAXIMUM ALLOWABLE LEAKAGE AREA, FOLLOWING TI-”E GUIDELINES FOR SMOKE BARRIER CONSTRUCTION. - ALL DOORS MUST BE PROVIEDED WITH TIGHT FITTING GASKETS, AND OPEN AGAINST THE DIRECTION OF ROOM /SHAFT PRESSURE. 9. DAMPERS USED FOR OUTDOOR AIR INTAKE, EXHAUST, OR RELIEF SHALL HAVE THE FOLLOWING MAXIMUM LEAKAGE RATES AT 1" W.G. (PER AMCA STANDARD 500): MOTORIZED DAMPERS:10 CFM /S.F. GRAVITY DAMPERS: 20CFM /S.F. (40 CFM /S.F. FOR DAMPERS SMALLER THAN 24" IN EITHER DIMENSION). 20. OUTSIDE AIR INTAKE, EXHAUST, AND RELIEF DAMPERS SERVING CONDITIONED SPACES MUST BE MOTORIZED (FAIL CLOSED) PER WSEC 1412.4.1, EXCEPT AS ALLOWED BY WSEC. 21. RETURN AIR SHAFTS TO BE CONSTRUCTED BY THE G.C. TO WITHSTAND A MINIMUM 20 PSF DIFFERENTIAL PRESSURE ACROSS THE WALL. DIFFERENTIAL PRESSURE IS BASED UPON THE MAXIMUM STATIC PRESSURE CAPABILITY OF FAN SYSTEMS SUBJECT TO AUTOMATIC DAMPER CLOSURE. 22. PRESSURIZATION SHAFTS SHALL BE CONSTRUCTED BY THE G.C. AS FOLLOWS: - SHAFTS SERVED BY PRESSURIZATION FANS RATED UP TO 1" STATIC PRESSURE TO BE CONSTRUCTED TO WITHSTAND 10 PSF DIFFERENTIAL PRESSURE. - SHAFTS SERVED BY PRESSURIZATION FANS RATED BETWEEN 1 -2.5" STATIC PRESSURE TO BE CONSTRUCTED TO WITHSTAND 20 PSF DIFFERENTIAL PRESSURE. - FOR SHAFTS SERVED BY PRESSURIZATION FANS RATED ABOVE 2.5" STATIC PRESSURE, CONTACT MECHANICAL ENGINEER. APN# 734060 -0480 LEGAL DESCRIPTION: RIVERSIDE INTERURBAN TRS TR 21 & 22 LESS POR LY NLY OF A LN 789.91 FT N AS MEAS ON ELY MGN CO RD FR SW COR LOT 31 SD SUBD LESS ST HWY TGW ALL TR 31 TGW TR 32 LESS S 200 FT OF POR E OF E LN SQUIRES REPLAT PROD N LESS ST HWY TITLE PROJECT ENGINEER ACCOUNT MANAGER SHEET METAL FOREMAN AIR BALANCE FOREMAN GENL PROJ MANAGER NAME GEORGE GRAHAM RUBEN CANAS CHRIS HOLLINGSWORTH RON LANDBERG DEAN CARTER COMPANY MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER PHONE NUMBER 206 - 768 -4288 206 -768 -4076 206 -407 -2620 206 - 571 -2661 206 - 255 -7653 EMAIL GEORGE.GRAHAM @MACMILLER.COM RUBEN.CANAS @MACMILLER.COM CHRIS .HOLLINGSWORTH @MACMILLER.COM RON.LANDBERG @MACMILLER.COM NAME TITLE NAME TITLE TM0.01 SCHEDULES - HVAC DM2.02 2ND FLOOR DEMO PLAN - HVAC TM2.02 2ND FLOOR PLAN - HVAC INSTALL (3) NEW SERIES FAN - POWERED VAV'S W/ ELECTRIC HEAT AND ASSOCIATED T'STATS. INSTALL (11) NEW GRD'S. RELOCATE (11) GRD'S. RELOCATE (2) SENSORS. MISC DUCTWORK. AIR BALANCE (9) ZONES. REVISIONS No changes shall b e made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. RECEIVF,�_ CITYOFTUKVmLA DEC 2 2 2011 PERMIT CENTER CV LL U �cC L.L a_ ca _ _ _Jd w w =_e D :�� OOwJ o�� ENGINEER: G GRAHAM CHECKED BY: B GEZON WA Lic No: MACDOFS980RU EXPIRES: 07 -06 -12 CAD: R VILLANUEVA W 0 REVISIONS: W 0 REVISIONS: z 0 F- 0 �NNJ C/) z 0 0 I.L. 0 LL W C!) LAST REVISED: 12 -19 -11 DATE PLOTTED: 12 -19 -11 ISSUE DATE: 12 -19 -11 DRAWING NUMBER: C-1816-7317040-00 SHEET NUMBER: TM0.01 Wednesday, December 21, 2011 10:48:48 AM F SEE 26"0 TEE-CA13 FOR FUTURE SON IN IATION .--� X11 , 2 N) i 26 "0 FOR 8x8 CD 200 8x8 CD 8x8 CD 200 \ 200 8x8 CD 200 48x24 /S PLENUM 3 ©x24 OPENI N (TYP.2 cn 10x10 CD 245 10x10 CD 275 8 >8 CD 220 8 CD x x x x x x X `if /xWx x x x x X x X x x x x x x x x x x x xl REVIEWED FOR CODE COMPLIANCE APPROVED JAN 0 3 2012 12x12 CD 300 f CD jIII I■ 12x12 CD 375(TYP.2) 12x12 D 300 12x12 375(TYP. 12x12 CD 375(TYP.2) i i Ii i City of Tukwila BUILDING DIVISION FSD -2 10x10 CD 245 I0x10 C 245 Q VAV -211 12X12 CD 260 10x10 CD 260(TYP.2) VAV -213 VAV -212 10" tskiltirAl M x 16x16 10x10 CD FSD -2- M I --ISd Key Plan cmRO �ui.n DEL'? 2 2011 PERMIT CENTER N 1/8" = 1' -0" n� W -6 O 0 U as 0 0) >— H 0 0 CO 0 N- � c a)O as czy � N O 0 O Q 0 00 N N— c - o •� .macmiller.com I I I I I I I I I I I I I I I I WA Lic No: MACDOFS980RU EXPIRES: 07 -06 -12 REVISIONS: 0 cc w d 1 1 1 1 1 1 1‹ ENGINEER: G GRAHAM CHECKED BY: B GEZON 0 REVISIONS: z 0 U F- z 0 U 0 U- 0 w LAST REVISED: 12 -19 -11 DATE PLOTTED: 12 -19 -11 CAD: ISSUE DATE: R VILLANUEVA 12 -19 -11 DRAWING NUMBER: C-1816-7317040-00 SHEET NUMBER: DM2.02 Wednesday, December 21, 2011 10:52:33 L 26 "0 TEE -CAP FOR FUTURE FOR CONT N TION SEE SHEE M 2 26 "0 FOR 48x24/S PLENUM 1 :0" 1\ :....�. iii -O3P E1 4-'�' (TYP. 10X10 245 8X8 195 8X8 8X8 210 8X8 210 80 O, N 10x10 CD �E- 275 s IVAV -220 VAV-21 9 s. 0 12X12 VAV -222 80 10X10 .100 100 8X8 195 8X8 0 195 12X12 12X12, 0300 300 11x11 SL 10x1 C1• 245- 12x12 CD 300 —J cn IA\ 11 CO 101x10 CD 245 L I. O 12X12 235 12X12 235 N X N 60 1 X8 1 VAV -215 12X12 235 VAV -216 VAV -217 VAV -2181 VAV-21 1 6X6 100 4 180 10X10 0190 VAV -214 10X10 190 3'x 3 VAV-21 3 VAV-21 2 N) 10" o W IMPARIZI M182184210111 I 0 111x10 D 2'5(TYf .2, 1 6x1 6 1 10x10 CD 1 275 0 INSTALL DDC SENSOR AT RETURN AIR GRILLE IF AN ALTERNATIVE WALL LOCATION CANNOT BE FOUND DUE TO FURNITURE CONFLICTS. FSD -2- REVIEWED FOR CODE COMPLIANCE APPROVED JAN 0 3 2012 City of Tukwila BUILDING DIVISION Key Plan Q arvdNwLa, DEC 2 21011 PERMIT CENTER 1/8" = 1' -0" • 0 C 0 LL CO CO O N- ✓ I- co co < ti rr aiO � N U) Li 7 O C 9) 00 N N O a. .macmiller.com 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 7_1 rn N U, 0 w a I I I I I I l< PHARMACY F L2 WA Lic No: MACDOFS980RU EXPIRES: 07 -06-12 REVISIONS: w Q 0 z 0 U, z 0 0 I-- U) z 0 0 OC 0 LL 0 L!J (I) ENGINEER: LAST REVISED: G GRAHAM 12 -19 -11 CHECKED BY: DATE PLOTTED: B GEZON 12 -19 -11 CAD: ISSUE DATE: R VILLANUEVA 12 -19 -11 DRAWING NUMBER: C -1816- 7317040 -00 SHEET NUMBER: TM2.02