HomeMy WebLinkAboutPermit PG10-035 - WESTFIELD SOUTHCENTER MALL - RESTROOM MODIFICATIONSSOUTHCENTER MALL
RESTROOM
MODIFICATIONS
2800 SOUTHCENTER MALL
PG1O-035
City 04/Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Inspection Request Line: 206 - 431 -2451
Web site: http: / /www.ci.tukwila.wa.us
PLUMBING /GAS PIPING PERMIT
Parcel No.: 9202470010
Address: 2800 SOUTHCENTER MALL TUKW
Project Name: SOUTHCENTER MALL RESTROOM MODIFICATIONS
Permit Number: PG 10 -035
Issue Date: 07/13/2010
Permit Expires On: 01/09/2011
Owner:
Name: WESTFIELD PROPERTY TAX DEPT
Address: PO BOX 130940 , CARLSBAD CA 92013
Contact Person:
Name: WAYNE JOHNSON
Address: 4000 DELRIDGE WY SW #200 , SEATTLE WA 98106
Email: wayne @smstemper.com
Contractor:
Name: PSF MECHANICAL, INC.
Address: 9322 14TH AVENUE SOUTH , SEATTLE, WA 98108
Contractor License No: PSFMEI *090NZ
Phone: 206 - 624 -2777
Phone: 206 764 -9663
Expiration Date: 10/03/2011
DESCRIPTION OF WORK:
DEMOLITION AND CAPPING OFF OF (4) WATER CLOSETS, (4) LAVATORIES AND (1) FLOOR
DRAIN
Value of Plumbing /Gas Piping: $10,000.00 Uniform Plumbing Code Edition: 2006
Fees Collected: $76.13 International Fuel Gas Code Edition: 2006
Permit Center Authorized Signature:
Date: 0 7//3/
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the erformance of work 2I am authorized to sign and obtain this plumbing /gas piping permit.
Signature: (4M _��� /•�i(T C� �/
Print Name: i C(-) /l/ t9/\ 6 F_
Date: / Z3-10
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
doc: UPC -4/10
PG 10 -035 Printed: 07 -13 -2010
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
Parcel No.: 9202470010
Address:
Suite No:
Tenant:
PERMIT CONDITIONS
2800 SOUTHCENTER MALL TUKW
SOUTHCENTER MALL RESTROOM MODIFICATIONS
Permit Number:
Status:
Applied Date:
Issue Date:
PG 10 -035
ISSUED
03/09/2010
07/13/2010
1: ** *PLUMBING AND GAS PIPING * **
2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila
Building Division.
3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing
inspector.
4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas
Code.
5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved.
6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code.
Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to
make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection.
7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless,
adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the
conditioned space shall be insulated to minimum R -3.
8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be
protected by steel nail plates not less than 18 guage.
9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing
piping shall be directly embedded in concrete or masonry.
10: All pipes penetrating floor /ceiling assemblies and fire - resistance rated walls or partitions shall be protected in
accordance with the requirements of the building code.
11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to
twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill,
frozen earth, or construction debris.
12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an
approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the
jurisdiction.
* *continued on next page **
doc: Cond -10/06
PG10 -035 Printed: 07 -13 -2010
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206 -431 -3665
Web site: http://www.ci.tukwila.wa.us
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and
this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work
construction or the performance of work.
Signature:
Print Name:
02/7t.
A
CsFOR G�
Date:
/3 -/D
ordinances governing
or local laws regulating
doc: Cond -10/06 PG10 -035
Printed: 07 -13 -2010
•
CITY OF TUKWILA
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.c.i.tukwila. wa. us
Building Permit No.
Mechanical PermitN[o
Public Works Permit No:
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**Please Print**
King Co Assessor's Tax No..
Site Address: 2 800 fiCe-4TER--. Suite Number: N7/4/— Floor.
Tenant Name: 144 e FIE-12. New Tenant: Yes
Property Owners Name: jA-4-E P t,(11.4-C__..
Mailing Address: C33 iAflU
City
State Zip
g
v , _
CONTACT PERSON = who do we contact when your permit is ready to be issued
Name: 14 1,p4.-"rf c) 0-1-4 Day Telephone: 2..c.63 ('2'f. 27
Mailing Address: 1-210040 bEllg,/,4„ tr AO-VW
City State Zip
E-Mail Address: WAY ST&-7,176e • e°1-7 Fax Number: 2c--)6> - 2-`/, Z-? 3
•
•CoNitaikeToRill■IFORMATION. •
„z•
7A67-
Company Name: 7
Mailing Address:
Contact Person:
E-Mail Address:
Contractor Registration Number:
Company Name:
efri
t-Tic
City
Day Telephone:
Fax Number:
Expiration Date:
State
Zip
Mailing Address: 1/120c.> fv.(.0
City State Zip
Contact Person: iili4f/(le _iO4,-/A-4.Sc)"/ Day telephone: WC &:2-)4 277 7
E-Mail Address: '/» 42 - C....%),1 Fax Number: • 62-•
ENGINEER OF Allplani:must be wet stamped :b,. Engineer of Record
.„,
Company Name: )23e, 6 ibre-LS
ficq-A/Act—, /444- f802-1
Mailing Address: 2-2--/
City State Zip
Contact Person: 24CLx- .86‘72A Day Telephone: r ZS" W-5-• 4/0°
E-Mail Address: Zitib6.4,1) )804 . " Fax Number: V2-5 V/-5— g
Q:\Applictions\Fonns-Appljcations On Line \3-2006 - Permit Application.doc
Revised. 9-2006
bh
Page 1 of 6
PLUMBING AND GAS PIPING PERMIT INFORMATION -.206-431-3670
PLUMBING AND GAS PIPING CONTRACTOR INFORMATION
Company Name: ./C /v / 5 % 6iZM /,c.(ey,Z1 4-7
7W-5 7747,
Mailing Address:
` City State Zip
Contact Person: /41x4-> -,x/9 W -AjsO� Day Telephone: 22) 6 ' �i2/- 2-7 77
E -Mail Address: Li//.� ->,,,t 14 Si?S%C /c??l`92 • co A-1 Fax Number: Z� 6 - G2 T ' Z- 7 3
Contractor Registration Number: Expiration Date:
Valuation of Plumbing work (contractor's bid price): $ /0/ 00 c)
Valuation of Gas Piping work (contractor's bid price): $
Scope of Work (•lease provide detailed information): • L/ 77 D
L -TS L
fit- /2 64-7,p//L-l‘
//2-047 A
Building Use (per Int'l Building Code): GO 1(6%X -L /1'%•4
Occupancy (per Intl Building Code):
Utility Purveyor: Water:
Sewer: •r—pI,e--Lf /4-14"
Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below:
: :Fixture:Ty..Pe: ,
:Qty!
Fixture Type:
'Qty` ..
Fixture .T a : = .:.
YP
.Qty
,. .
Fiii xtu "re .Type.
Qty
Bathtub or combination
bath/shower .
Drinking fountain or water
cooler (per head)
Wash fountain
Gas piping outlets
Bidet
Food -waste grinder,
commercial
Receptor, indirect
waste
Clothes washer, domestic
Floor drain
Sinks
Dental unit, cuspidor
Shower, single head trap
Urinals
Dishwasher, domestic,
with independent drain
Lavatory
Water Closet
Building sewer or trailer
`park sewer
Rain water system - per
drain (inside building)
Repair or alteration of water
piping and/or water treating
equipment
/
Water heater and /or
vent
Repair or alteration
of drainage or vent
piping
-
1
Additional medical gas
inlets/outlets - six or more
Medical gas piping system
serving one to five
inlets/outlets for specific gas
Industrial waste
pretreatment interceptor,
including its trap and vent,
except for kitchen type
grease interceptors
Q: W pplications\Fortns- Applications On Line\3 -2006 - Permit Applicalion.doc
Revised: 9 -2006
bh
Page 5 of 6
PERMIT APPLICATION. NOTES Applicable'to all permits in this application
of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
Building and Mechanical Permit
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
Plumbing Permit
The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested
in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED.TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR AUTHORIZED AGENT.
Signature: �,L_ �i�•�"
Date: / v
Print Name: (�-� �/��� _ _JDiii es-64 / Day Telephone: 24.4 ' ' 2 ' 17 ? 7
Mailing Address: 4{0040 16 & "Z-1 /66 IF Gds , . 2GXN St—At`% j 44 7/6
City State Zip
Date Application Accepted:
"1-5 -to
Date Application Expires: (�
Staff Initials:
Q:\ApplicalionsWorms- Applications On Line3-2006 - Permit Application.doc
Revised: 9 -2006
bh
Page 6 of 6
• 4P
J��I�A wqs City of Tukwila
Departinent of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206 - 431 -3665
Web site: http://www. ci. tukwi la. wa. us
RECEIPT
Parcel No.: 9202470010 Permit Number: PG 10 -035
Address: 2800 SOUTHCENTER MALL TUKW Status: APPROVED
Suite No: Applied Date: 03/09/2010
Applicant: SOUTHCENTER MALL RESTROOM MODIFICATIONS Issue Date:
Receipt No.: R10 -01303 Payment Amount: $60.90
Initials: LAW Payment Date: 07/13/2010 04:09 PM
User ID: 1632 Balance: $0.00
Payee: PSF MECHANICAL INC
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Check 014456 60.90
Authorization No.
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
PLUMBING - NONRES
000.322.103.00.00 60.90
Total: $60.90
PAYMENT
RECEIVED
doc: Receiot -06 Printed: 07 -13 -2010
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206 - 431 -3665
Web site: http://www.ci.tukwila.wa.us
RECEIPT
Parcel No.: 9202470010 Permit Number: PG 10 -035
Address: 2800 SOUTHCENTER MALL TUKW Status: PENDING
Suite No: Applied Date: 03/09/2010
Applicant: WESTFIELD MALL RESTROOM MODIFICATION Issue Date:
Receipt No.: R10 -00403
Initials: WER
User ID: 1655
Payment Amount: $15.23
Payment Date: 03/09/2010 02:04 PM
Balance: $60.90
Payee: S M STEMPER ARCHITECTS
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Check 15180 15.23
Authorization No.
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
PLAN CHECK - NONRES
000.345.830 15.23
Total: $15.23
PAYMENT
RECEIVED
doc: Receiot -06 Printed: 03 -09 -2010
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
INSPECTION RECORD
Retain a copy with permit
P6ib -bas
PERMIT NO.
(206)431 - ,Co
Pro ect:
Sj\kLec.A.1-i-0.-/ / VV \ A c (
Type of Inspection:
(=' (n, el .1
Address:
Date Called:
Special Instructions:
O u i g Zc o f
Date Wanted: (a.m.
Requester:
Phone No:
2 a(— Zg A— 31(2 ?
'-'14,,,.., Approved per applicable codes. Corrections required prior to approval.
r
COMMENTS:
Inspect
Date:
IAAA 2 - O
60.00 R- NSPECTION FEE REQUIRED. 'riorf to inspection, fee must be
aid at 6.00 Southcenter Blvd., Suite 10'. C 11 to schedule reinspection.
Rec - pt N • .:
Date:
• •
S.M. STEMPER • ARCHITECTS
A Professional Limited Liability Company
March 22, 2010
City of Tukwila, Department of Community Development
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
RE: Southcenter Mall Restrooms
Project No. PG10 -035
Attention: Allen Johannessen, Plans Examiner
Listed below is the written response to the `Building Division Review Memo' dated March 19, 2010
which we received on March 22, 2010. In accordance to the memo we are submitting written clarification
regarding the Plumbing fixture count as follows.
1. Item #1 —The Plumbing Requirements listed on the cover sheet has been updated per your request in
accordance to the Washington State Amendments Table 2902.1 for Group M, using the 200 square
feet per occupant as sated in the amendments. The changes have been clouded and identified with a
triangle `1' for clarity purpose on sheet T1.0. Please see the drawings submitted as required per City
of Tukwila.
Please accept this written response to your memo, regarding the revisions per the Washington State
Amendments. If you should have any further questions please feel free to call.
Sincerely,
Wayne E. Johnson, AIA
S.M. Stemper Architects
Cc: Pat Burns, Westfield
Encl.: . Revision Submittal Form
4000 DELRIDGE WAY SW • SUTTE 200 . SEATTLE, WA 98106 • 206/624 -2777 . FAX 206/624 -2973
•
City of Tukwila
Jim Haggerton, Mayor
March 19, 2010
Department of Community Development Jack Pace, Director
Wayne Johnson
S M Stemper Architect
4000 Delridge Way SW #200
Seattle, WA 98106
RE: Correction Letter #1
Plumbing /Gas Piping Permit Application Number PG10 -035
Southcenter Mall Restrooms — 2800 Southcenter Mall
Dear Mr. Johnson,
This letter is to inform you of corrections that must be addressed before your plumbing /gas piping permit
can be approved. All correction requests from each department must be addressed at the same time and
reflected on your drawings. I have enclosed comments from the Building Department. The Public Works
Department has no comments at this time.
Building Department: Allen Johannessen at 206 433 -7163 if you have questions regarding
the attached memo.
Please address the attached comments in an itemized format with applicable revised plans,
specifications, and /or other documentation. The City requires that two (2) sets of revised plans,
specifications and /or other documentation be resubmitted with the appropriate revision block.
In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every
resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person
and will not be accepted through the mail or by a messenger service.
If you have any questions, please contact me at (206) 431 -3670.
Sincerely,
Bill Rambo
Permit Technician
encl
File: PG10 -035
W:\Permit Center \Correction Letters \2010\PG10 -035 Correction Letter #1.DOC
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665
Tukwila Building Division
Allen Johannessen, Plan Examiner
Building Division Review Memo
Date: March 19, 2010
Project Name: Southcenter Mall Restrooms
Permit #: PG10 -035
Plan Review: Allen Johannessen, Plans Examiner
The Building Division conducted a plan review on the subject permit application. Please address the
following comments in an itemized format with revised plans, specifications and /or other applicable
documentation.
(GENERAL NOTE)
PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size).
(If applicable) Structural Drawings and structural calculations sheets shall be original signed wet
stamped, not copied.)
** The building code for this permit shall need some revisions that may affect the number of fixtures for
this permit. Please review the comment below and coordinate with the building plan changes if
necessary.
1. The Plumbing Requirements table on the cover sheet makes reference to building and plumbing code
tables not adopted by Washington State building code council. The current Washington State
Amendments Table 2902.1 for Group "M" uses 200 square feet per occupant to calculate number of
occupants and determine the number of fixtures required. The new mall was constructed under the
current Washington State amendments where the restrooms were calculated to meet current codes.
Therefore a revision of the table shown on the cover sheet shall be revised with the new calculations
to meet current Washington State amendments. Provide calculations in a new table that identify the
total square footage of the mall (minus the anchor buildings) to include both floors. Divide that
number by 200 square feet per occupant to indicate the total occupants. That final number then shall
be divided in half to show the total number of half for male and half for female. From that number
the table will indicate the required fixtures. Show the number of existing public restrooms and
fixtures to determine as to how many fixtures may (or may not) be removed yet still maintain code
requirements for required fixtures. (IBC Table 2902.1 Washington State Amendments)
Should there be questions concerning the above requirements, contact the Building Division at 206 -431-
3670. No further comments at this time.
• PERMITCQORpCppyr
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: PG10 -035
DATE: 03/23/10
PROJECT NAME: SOUTHCENTER MALL RESTROOMS
SITE ADDRESS: 2800 SOUTHCENTER MALL
Original Plan Submittal
X Response to Correction Letter #
Response to Incomplete Letter #
Revision # after Permit Issued
DEPARTMENTS:
Division
Public Works
Fire Prevention
❑ Structural
Planning Division
❑ Permit Coordinator
n
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete
Comments:
Incomplete n
DUE DATE: 03/25/10
Not Applicable
Permit Center Use Only
INCOMPLETE LETTER MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
LETTER OF COMPLETENESS MAILED:
TUES /THURS ROUTING:
Building
Please Route Structural Review Required n No further Review Required n
REVIEWER'S INITIALS:
DATE:
APPROVALS OR CORRECTIONS:
Approved
Notation:
REVIEWER'S INITIALS:
Approved with Conditions
DUE DATE: 04/22/10
Not Approved (attach comments) n
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections:
Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents/routing slip.doc
2 -28 -02
•PE T PY •
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: PG10 -035 DATE: 03 -09 -10
PROJECT NAME: SOUTHCENTER MALL RESTROOMS
SITE ADDRESS: 2800 SOUTHCENTER MALL
X Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter #
Revision # After Permit Issued
DEPAR6T�MENTS:
uilding ivision
u
�uulic Wor s
Fire Prevention
Structural
n
n
Planning Division
Permit Coordinator
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete Incomplete n
DUE DATE: 03 -11 -10
Not Applicable
n
Comments:
Permit Center Use Only
INCOMPLETE LETTER MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
LETTER OF COMPLETENESS MAILED:
TUES /THURS ROUTING:
Please Route
Structural Review Required
REVIEWER'S INITIALS:
Fl No further Review Required
DATE:
APPROVALS OR CORRECTIONS:
DUE DATE: 04 -08 -10
Approved n Approved with Conditions ❑ Not Approved (attach comments)
Notation:
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only !l
CORRECTION LETTER MAILED: — 4 j(� rat V
Departments issued corrections: Bldg Fire ❑ Ping ❑
PW ❑ Staff Initials:
Documents /routing slip.doc
2 -28 -02
IP •
City of Tukwila
Steven M Mullet, Mayor
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http://www.citukwila.wa.us
REVISION SUBMITTAL.
Steve Lancaster, Director
Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through
the mail, fax, etc.
Date: 3/2 l D Plan Check/Permit Number: PG 10 -03 5
❑ Response to Incomplete Letter #
® Response to Correction Letter # 1
❑ Revision # after Permit is Issued
❑ Revision requested by a City Building Inspector or Plans Examiner MAR
23 2010
Project Name: Southcenter Mall Restrooms °ERN??
Project Address: 2800 Southcenter Mall
Contact Person: lAJAYi4i A0 on.1 Phone Number: 2c=,- 6 • 6 - Z? 7 7
Summary of Revision:
errylgtoti%
'R IS j -ham tPLAt tr *I A.,(1)
L- .. Ltl F I Inl (aT c>o� S-ii kY 10 lk 7vW T5
T Mi -E 2-1 (2-t _ /fit_ --.- l s t owj
Sheet Number(s):
t: 0
"Cloud" or highlight all areas of revision including date of revision
Received at the City of Tukwila Permit Center by: Mr'
Entered in Permits Plus on
\ applications \forms - applications on line \revision submittal
Created: 8 -13 -2004
Revised:
Contractors or Tradespeople Priter Friendly Page
•
General /Specialty Contractor
A business registered as a construction contractor with LEI to perform construction work within the scope of
its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Business and Licensing Information
Name P S F MECHANICAL UBI No. 601318369
INC
Phone 2067649663 Status Active
Address 9322 14Th Ave S License No. PSFMEI'090NZ
Suite /Apt. License Type Construction Contractor
City Seattle Effective Date 8/9/1991
State WA Expiration 10/3/2011
Date
Zip 98108 Suspend Date
County King Specialty 1 Heating /Vent /Air - Conditioning And Refrig
(Hvac /R)
Business Type Corporation Specialty 2 Unused
Parent
Company
Other Associated Licenses
License
Name
Type
Specialty
1
Specialty
2
Effective
Date
Expiration
Date
Status
EDENN "225LK
EDEN
NURSERIES
Construction
Contractor
General
Unused
6/12/1978
6/1/1986
Archived
Business Owner Information
Name
Role
Effective Date
Expiration Date
BEARDSLEY, WARREN 5
Cancel Date
01/01/1980
Bond Amount
CRITCHLOW, JAMES D
4
01/01/1980
08973126
Bond Information
Page 1 of 2
Bond
Bond Company Name
Bond Account Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Bond Amount
Received Date
4
FIDELITY E DEPOSIT
CO OF MD
08973126
08/08/2009
Until Cancelled
$6,000.0007/10/2009
/07/2009
3
HARTFORD FIRE INS
52BSBFA6327
08/08/2008
Until Cancelled
08/08/2009
$6,000.0007/08/2008
/28/2009
2
FEDERAL INS CO
81241859
08/08/2001
08/08/2008
$6,000.00
10/01/2001
Assignment of Savings Information No records found for the previous 6 year period
Insurance Information
Insurance
Company Name
Policy Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Amount
Received Date
17
WAUSAU
BUSINESS INS
CO
TBJZ91452741029
10/01/2009
10/01/2010
$1,000,000.0010
/07/2009
16
WAUSAU
UNDERWRITERS
INS. CO.
TBJZ9145274109
10/01/2009
10/01/2010
$1,000,000.0009
/28/2009
15
TRAVELERS
PROPERTY CAS
INS CO
DTEC0527D0578TIL08
10/01/2008
10/01/2009
$1,000,000.00
09/23/2008
14
ZURICH
AMERICAN INS
CO
CP0399986500
10/01/2006
10/01/2008
$1,000,000.00
09/14/2007
13
ST PAUL FIRE E
MARINE INS CO
DTEC0526D8294TIL05
10/01/2005
10/01/2007
$1,000,000.0009
/18/2006
https://fortress.wa.gov/lni/bbip/Print.aspx
07/13/2010
WESTFIELD MALL AT SOUTHCENTER
NT
IMPROVE
TROOM
Code Summary
CODE SUMMARY:
IBC 2006 - INCLUDING WASHINGTON STATE AMENDMENTS
FULLY SPRINKLED BUILDING - TO BE SUBMITTED UNDER SEPARATE PERMIT.
MECHANICAL DESIGN - TO BE SUBMITTED UNDER SEPARATE PERMIT
ELECTRICAL DESIGN - TO SE SUBMITTED UNDER SEPARATE PERMIT
PLUMBING DESIGN - TO BE SUBMITTED UNDER SEPARATE PERMIT.
PERMIT TYPE - TENANT IMPROVEMENT AT EXISTING COVERED MALL
BUILDING
SITE INFORMATION:
MALL COMMONS- EXISTING WOMEN* RESTROOM
ADDRESS:
2800 SOUTHCENTER
TUKWILA, WA 98188
TAX PARCEL NUMBER:
262304 -9023
ZONING USE:
TUC - TUKWILA URBAN CENTER
TENANT IMPROVEMENT SUMMARY:
TOTAL SQUARE FEET:
160 S.F. (EXISTING WOMENS RESTROOM)
222 S.F. (DEMOLITION AREA WITHIN WOMEN* RESTROOM)
538 SF. REVISED SQUARE FEET OF WOMEN* RESTROOM
OCCUPANCY GROUP: WESTFIELD MALL - M - COVERED MALL
EGRESS REQUIREMENTS: EXISTING NO MODIFICATIONS
PER TABLE 1015.1 THE MAXIMUM OCCUPANT LOAD FOR ONE EXIT WITHIN
OCCUPANCY TYPE 'M' IS 49. (TABLE 1015.1)
MINIMUM CORRIDOR WIDTH OF 44" - PROVIDED THEREFORE ACCEPTABLE
FIRE RESISTANCE REQUIREMENTS:
CORRIDORS NOT REQUIRED TO BE I -HOUR RATED PER TABLE 1011.1 FOR
FULLY SPRINKLERS BUILDING IN OCCUPANCY TYPE B.
DOORWAYS TO EXITS PASSAGEWAYS SHALL BE PROTECTED BY I -HOUR
FIRE DOOR ASSEMBLY THAT INCLUDES SELF CLOSING DEVICE. - SECTION
402.45.)
EACH TENANT SHALL BE SEPARATED BY A FIRE PARTITION IN
ACCORDANCE TO SECTION 108.
CONTRACTOR 51-IALL COORDINATE WITH BUILDING INSPECTOR FOR
STAGGERING OF GYPSUM WALL BOARD ON TENANT DEMISING WALLS THAT
HAVE PREVIOUSLY RECIEVED GYPSUM WALL BOARD ON ADJACENT
TENANTS DEMISING WALL
PLUMBING REQUIREMENTS:
(PER TABLE 2902.1 WASHINGTON STATE AMMENDMENTS)
TOTAL EXISTING SQUARE FEET:
1ST FLOOR - 663,121
2ND FLOOR - 241,688
3RD FLOOR - 84,440
TOTAL SF MINUS ANCHOR BUILDINGS - 9891355 SF
989,855 SF / 200 OCCUPANCY LOAD FACTOR = 4,949
4,949 / 2 = 2,414 WOMEN AND 2,414 MEN
WC FIXTURE REQUIRED FOR WOMEN = 5:301 -400 PLUS 1 FOR EVERY 50
AFTERWARD: 2014 / 150 = 13.82 THUS 14 FIXTURES
TOTAL WC FIXTURES REQUIRED FOR WOMEN = 19 FIXTURES
TOTAL EXISTING WC FIXTURES FOR WOMEN = 38 (+ 1 BACK OF HOUSE UNISEX
FIXTURES)
THEREFORE OK TO DELETE 4 EXISTING FIXTURES FOR A TOTAL COUNT OF
34 (+ 1 BACK OF HOUSE UNISEX FIXTURES)
TOTAL REQUIRED LAVATORIES I PER 2 WATER CLOSETS
TOTAL EXISTING LAVATORIES SERVING WOMEN = 25 (+ 9 UNISEX
LAVATORIES WITHIN BACK OF HOUSE UNISEX AND FAMILY CHANGING
ROOMS)
19 WATER CLOSETS/ 2 = 95 THEREFORE 10 WATER CLOSETS ARE REQUIRED
THEREFORE OK TO DELETE 4 LAVATORIES FOR A TOTAL COUNT OF 21
LAVATORIES SERVING WOMEN (+ 9 UNISEX LAVATORIES WITHIN BACK OF
HOUSE UNISEX AND FAMILY CHANGING ROOMS)
Separate Permits
THE FOLLOWING ITEMS SHALL BE UNDER SEPARATE PERMIT:
FIRE ALARM, FIRE SPRINKLER SIGNAGE, MECHANICAL, ELECTRICAL, AND
PLUMBING SHALL BE UNDER SEPARATE PERMIT TO BE SUBMITTED BY
CONTRACTOR
MODIFI
General Notes
I. ALL WORK TO BE PERFORMED IN COMPLIANCE WITH ALL APPLICABLE CODES, LAWS AND REGULATIONS OF ALL AUTHORITIES
HAVING JURISDICTION OVER THE WORK.
2. CONTRACTOR TO VERIFY ALL DIMENSIONS, PROPERTY LINES, LEASE LINES, MEASUREMENTS AND CONDITIONS IN THE FIELD BEFORE
BEGINNING WORK ANY DISCREPANCIES, ERRORS OR OMISSIONS TO BE BROUGHT TO THE ATTENTION OF THE ARCHITECT
IMMEDIATELY.
3. THE ARCHITECT WILL HAVE A REPRESENTATIVE ON SITE, AT SCHEDULED MEETINGS AND SITE VISITS TO OBSERVE THE
CONSTRUCTION FOR COMPLIANCE WITH THE DESIGN INTENT AND TO ASSIST THE CONTRACTOR IN RESOLVING VARIATIONS IN THE
EXISTING CONSTRUCTION. THESE DOCUMENTS ADDRESS ALL KNOWN CONDITIONS, BUT IT IS ANTICIPATED THAT HIDDEN CONDITIONS
WILL BE ENCOUNTERED DURING CONSTRUCTION. THE ARCHITECT WILL OBSERVE ALL SUCH HIDDEN CONDITIONS AND ISSUE
CLARIFICATIONS OR MODIFICATIONS OF THE DESIGN TO ADDRESS SUCH CONDITIONS AND WILL DOCUMENT ALL CHANGE*.
4. UNLESS OTHERWISE NOTED, ALL ANGLES TO BE RIGHT ANGLES, ALL LINES WHICH APPEAR PARALLEL ARE TO BE PARALLEL, AND
ALL ITEMS WHICH APPEAR CENTERED ARE TO BE CENTERED. CONTRACTOR TO BE RESPONSIBLE FOR MAINTAINING ALL LINES
TRUE, LEVEL, PLUMB AND SQUARE.
5. DETAILED AND /OR LARGER SCALE DRAWINGS TAKE PRECEDENCE OVER GENERAL AND SMALLER SCALE DRAWINGS. POSTED
DIMENSIONS WILL TAKE PRECEDENCE OVER SCALED DIMENSIONS. CONTRACTOR SHALL NOT SCALE DRAWINGS FOR DIMENSIONS.
6. ALL ATTACHMENTS, CONNECTIONS AND FASTENINGS OF ANY NATURE ARE TO 8E PROPERLY AND PERMANENTLY SECURED IN
CONFORMANCE WITH THE BEST PRACTICES OF THE BUILDING INDUSTRY. DRAWINGS SHOW ONLY SPECIAL REQUIREMENTS TO ASSIST
THE CONTRACTOR AND DO NOT SHOW EVERY DETAIL.
1. DETAILS SHOWN IN THESE DRAWINGS ARE TYPICAL AND WILL APPLY UNLESS OTHERWISE NOTED OR SHOWN. DETAILS OF
CONSTRUCTION NOT FULLY SHOWN ARE TO BE OF THE SAME NATURE AS THOSE DRAWN FOR SIMILAR CONDITIONS.
8. CONTRACTOR TO PROTECT EXISTING FURNISHINGS, FIXTURES, EQUIPMENT AND LANDSCAPING FROM DAMAGE. CONTRACTOR TO
REPLACE IN KIND ANY SUCH ITEMS DAMAGED, IN ITS ENTIRETY TO LEVEL OF SATISFACTION OF ARCHITECT.
9. CONTRACTOR TO COORDINATE ALL OPERATIONS WITH OWNER INCLUDING: SITE ACCESS, MATERIALS STORAGE AND STAGING,
INTERRUPTION OF ELECTRICAL AND MECHANICAL SERVICES AND TIMING OF NOISY OR DISRUPTIVE OPERATIONS. CONTRACTOR TO
VERIFY SEQUENCE OF WORK WITH OWNER
10. ALL INTERIOR GWB 15 B" TYPE X ON METAL STUDS OR FURRING CHANNELS UNLESS NOTED OTHERWISE, SIZES AS DIMENSIONED ON
PLANS. SEE NOTE FOR WATER RESISTANT GWB.
11. PROVIDE WATER RESISTANT (PAPERLESS) TYPE X GWB IN ALL TOILET ROOMS, WARM/ASH AND WET AREAS.
12. PROVIDE FINISH WALL BEHIND ALL EQUIPMENT AND CASEWORK
13. PROVIDE ALL ACCESSIBLE SIGNAGE AS REQUIRED BY LOCAL OR APPLICABLE JURISDICTION.
14. PROVIDE ONE TYPE 5E- 2A -1013C FIRE EXTINGUISHER PER 3000 SF AND NOT MORE THAN 15 FT OF TRAVEL DISTANCE,
15. THERE SHALL BE NO BACK -TO -BACK ELECTRICAL, TELEPHONE, OR OTHER OUTLETS. SEPARATE OUTLETS BY 6" AT AT NONRATED
PARTITIONS. SEPARATE OUTLETS BY 24" MIN. AT FIRE RATES PARTITIONS.
16. WHERE HVAC OR OTHER MECHANICAL, ELECTRICAL, AND PLUMBING ITEMS PENETRATE PARTITIONS, STUDS 51-IALL BE BRACED AND
FRAMED TO STRUCTURE AS REQUIRED TO PROVIDE ADEQUATE SUPPORT. ALL PENETRATIONS THROUGH RATED WALLS SHALL BE
SEALED TO PROVIDE FIRE, SMOKE, AND /OR ACOUSTICAL ISOLATION OF SPACES WITH APPROPRIATE FIRE STOP MATERIAL.
11. PROVIDE EXIT ILLUMINATION PER LOCAL CODES.
18. FURNISH AND INSTALL THE FIRE PROTECTION SYSTEM TO ACCOMMODATE THE CONFIGURATION INDICATED ON THE PLANS. COMPLY
WITH ALL GOVERNING ORDINANCES AND LANDLORD CRITERIA. CONTRACTORS SHALL OBTAIN ALL NECESSARY PERMITS.
19. INSTALL FIRE ALARM SYSTEMS TO COMPLY WITH LANDLORD CRITERIA AND LOCAL CODES AS REQUIRED.
20.FIRE SPRINKLER SYSTEM WORK AND FIRE ALARM SYSTEM WORK IS TO BE SUBMITTED UNDER SEPARATE PERMITS.
21. PROVIDE FINISH FLOOR UNDER ALL EQUIPMENT AND CASEWORK
Scope of Work
SCOPE OF WORK SHALL INCLUDED THE REDUCTION OF
SIZE TO THE EXISTING WOMEN* BATHROOM. DEMOLITION
WORK SAHLL INCLUDE, BUT NOT BE LIMITED TO,
DEMOLTION OF EXSTING WALL, (4) WATER CLOSETS,
LIGHT FIXTURES, LAVATORIES, COUNTERTOP, AND
VANITIES.
NEW CONSTRUCTION 15 TO INCLUDE RELOCATED TENANT
SEPARATION WALL, RELOCATION OF EXISTING BABY
CHANGING STATION COUNTERTOP, ALL FINISHES ARE TO
MATCH (E) FINISHES AND ALLOW FOR SEAMLESS
TRANSITIONS.
Drawing
I
ARCHITECTURAL
T1.0
TITLE - COVER SHEET
A0.1
DEMOLITION PLAN AND DEMOLITION RCP
A1.0
FLOOR PLAN AND RCP
A2.0
INTERIOR ELEVATIONS AND DETAILS
M1.0
MECHANICAL LEGEND, SYMBOLS, NOTES
AND DEMOLITION PLAN
E1.0
FLOOR PLAN AND REFLECTED CEILING PLAN
E2.0
ELECTRICAL SPECIFICATION
Vicinity Map
FI EC . PY
Permit No. 0
Plan review approval is subject to errors and omissions.
Approval of construction documents does not authorize
the violation of any adopted code or ordinance. Receipt
of approved Field Copy and conditio s is acknowledged:
By
Date: -7- /3
City Of lbkwila
BUILDING DIVISION
REVISIONS
No changes shall be made to the scope
of work rk without prior approval of
Tukwila Building Division.
NOTE: Revisions will require a new plan submittal 1
and may include additional plan review fees.
Project Directory
WEA SOUTHCENTER LLC
633 5outhcenter
Seattle, WA 98188
SENIOR GENERAL MANAGER
ANDREW CIARROCHI
T - 206246.0423
F - 206244.8601
MALL OPERATIONS:
PAT BURNS
T - 206246.0423
F - 206244.8601
C - 206.1869011
PBUiaJ*•WESTFIELD COM
ARCHITECT
SM. *TEMPER ARCHITECTS, PLL.C.
4000 Delridge Way SW Suite 200
Seattle, Washington 98106
CONTACT: WAYNE JOHNSON, PROJECT MANAGER
(206) 624 -2111
(206) 624 -2913 FAX
wayne•amstemper.com
MECHANICAL ENGINEER
BOGARD ENGINEERS, PLL.C.
22121 11TH AVE, SUITE 11I
BOTHELL, WA 98021
PHONE: 425.415.6100
FAX 425.415.6111
CONTACT: LEE BOGARD
Lbogard•bogeng.net
ELECTRICAL ENGINEER
CROSS ENGINEERS, INC.
2401 NORTH 31ST STREET, SUITE 100
TACOMA, WA 98401
PHONE: 253.159.0118
FAX: 253.159.1819
CONTACT: WES Nc KEAN
WesM•CrossEng ineers.com
Site Plan
NORDSTROM
3 LEVELS
I 1
1 1
Li
macys
4 LEVELS
"IMP!
MIN
rarriwitid,
MIN
II
MI I
1
L
.r-
Ell Ell
Ise
s.
REVIEWED FOR
CODE COMPLIANCE
APPROVED
APR 0 2 2010
City of Tukwila
BUILDING DIVINSICM
mervyws
2 LEVELS
1,
,111 NM '■ o Mir
1
•11
RESTR
MODIF
••
C
ONS
Eno
1
iwoomm
u
111
!a r r� imE ritual
ErxISnNCC
3' �, 3 LEVELS _!
° 3 LEVELS .
1
anRRu
MAR 2 3 2010
PERMIT CENTER ip
CORRECTION
LTR#
04-1-025
WESTFIELD DESIGN &
CONSTRUCTION
11601 Wilshire Boulevard, 11th
Floor Los Angeles, Califomia
90025 -1748
Telephone 310 478 4456
Facsimile 310 478 4468
THIS DRAWING IS AN INSTRUMENT OF SERVICE. 15 THE PROPERTY OF THE
ARCHITECT AND MAY NOT BE REPRODUCED VATHOUT THE ARCHITECTS
PERMISSION AND UNLESS THE REPRODUCTION CARRIES THE ARCHITECTS
NAME. ALL DESIGN AND OTHER INFORMATION SHOWN ON 1HE DRAWING ARE
FOR USE ON THE SPECIFIED PROJECT ONLY AND SHALL NOT BE USED
OTHERWISE VATHOUT WRITTEN PERMISSION FROM 1HE ARCHITECT
S.M. STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (206) 624 -2973
z
0
0
LL
0
CG
0
0
ct
w
ct
F-
z
w
w
0
_
H-
z
z
z
w
ISSUE / ' \3 2 OF TUKWILA
ISSUE
DATE:
PERMIT SET
MAR. 5, 2010
PROJECT ARCHITECT
WEJ
PROJECT MANAGER
WEJ
TITLE - COVER
SHEET
T1.0
SMSA #0923.01
ABBREVIATIONS
T'STAT
SENS
CD
CG
AFF
ARCH.
COP
DWG
EAT
ELECT.
EER
EFF
I.E.
IPLV
LAT
MC
MECH.
P.O.C.
TYP
(E)
U.O.N.
THERMOSTAT
SENSOR
CEILING DIFFUSER
CEILING GRILLE
ABOVE FINISHED FLOOR
ARCHITECT / ARCHITECTURAL
COEFFICIENT OF PERFORMANCE
DRAWING
ENTERING AIR TEMP.
ELECTRICAL
ENERGY EFFICIENCY RATING
EFFICIENCY / EFFICIENT
INVERT ELEVATION
INTEGRATED PART LOAD VALUE
LEAVING AIR TEMP.
MECHANICAL CONTRACTOR
MECHANICAL
POINT OF CONNECTION TO EXISTING
TYPICAL
EXISTING ITEMS
UNLESS OTHERWISE NOTED
GENERAL NOTES
PIPING SYMBOLS
INSTALL SEISMIC BRACING FOR ALL DUCTWORK, EQUIPMENT AND PIPING
PER I.B.C. REQUIREMENTS.
THE MECHANICAL CONTRACTOR SHALL VISIT THE JOB SITE PRIOR TO
BEGINNING WORK IN ORDER TO OBSERVE EXISTING CONDITIONS. VERIFY
EXACT SIZE, LOCATION AND CONDITION OF ALL EXISTING SYSTEMS, DUCTS
PIPES, UTILITIES AND BUILDING STRUCTURE.
REFER TO ELECTRICAL DRAWINGS FOR ELECTRICAL CHARACTERISTICS OF
MECHANICAL EQUIPMENT (VOLTAGES, ETC.).
PIPE DOWN
PIPE UP
HOSE BIBB / WALL HYDRANT
HOSE ' DRAIN VALVE
VENT THROUGH ROOF
FLOOR DRAIN
FLOOR SINK
CLEAN OUT
WASTE
VENT
COLD WATER ( DOMESTIC )
HOT WATER ( DOMESTIC )
HOT WATER RECIRC. ( DOMESTIC )
GENERAL SYMBOLS
P -1 I
DETAIL REFERENCE
SECTION REFERENCE
w
00
MECHANICAL NOTES
EQUIPMENT IDENTIFICATION
DETAIL NUMBER
DRAWING ON WHICH
SECTION IS LOCATED
SECTION NUMBER
DRAWING ON WHICH
SECTION IS LOCATED
REVISION IDENTIFICATION
ADDENDUM IDENTIFICATION
FLAG NOTE
1. THE FOLLOWING NOTES APPLY TO ALL MECHANICAL DRAWINGS. ADDITIONAL
MECHANICAL NOTES MAY BE INDICATED ON EACH MECHANICAL, PLUMBING
AND FIRE PROTECTION DRAWING.
2. REFER TO ARCHITECTURAL DRAWINGS FOR GENERAL CONSTRUCTION.
3. MECHANICAL DRAWINGS SHOW APPROXIMATE LOCATIONS FOR GRILLES AND DIFFUSERS. REFER TO
ARCHITECTURAL REFLECTED CEILING PLANS AND ELEVATIONS FOR EXACT LOCATIONS.
4. ARRANGE HVAC EQUIPMENT SO THAT ACCESS CLEARANCES INDICATED BY DRAWINGS, REQUIRED BY
CODES OR RECOMMENDED BY MANUFACTURER ARE PROVIDED.
5. REFER TO PIPING DIAGRAMS AND DETAILS FOR REQUIRED FITTINGS, VALVES, ETC. FLOOR PLANS
AND SECTIONS INDICATE EQUIPMENT LOCATIONS AND GENERAL PIPE ROUTING ONLY. PROVIDE
PIPING SHOP DRAWINGS COORDINATED WITH OTHER TRADES. REFER TO SPEC. FOR ADDITTIONAL
SHOP DRAWING REQUIREMENTS.
REMOVE WALL CLEANOUT
REMOVE EXISTING
FAUCET, FAUCET
WASTE & VENT
FIXTURE
VATORY,
NTROLS,
IPING &
CARRIER.
REMOVE EXISTIN WASTE,
VENT, HW & C PIPING
IN WALL Tq IXTURES.
DISCONNECT
BRANCH PIPING
BRANCH PIPE &
HEADS,
SPRINKLER ' L
& REMOVE -I—
SPRINKLER
2 TYPICAL. J
REMOVE EXHAUST GRILLE
& BRANCH DUCT
REMOVE FLOOR DRAIN,
CAP PIPE BELOW FLOOR
I1 EMOVE
MAIN EXHAJSI DUCT
0
REMOVE CLEAN —OUT
& WASTE PIPING
DISCONNECT & REMOVE EXISTING
I WATER PIPING & FLUSH VALVES TO
WATER CLOSETS. 4 TYPICAL.
%
\‘'" mss'
CAP EXISTING HW & CW PIPING
TO DEMO' FIXTURES IN WALL.
INSTALL NEW WALL CLEA —OUT &
CONNECT TO EXISTING WA TE PIPE
TRASH
EXISTIN
LAVATORY FIXTURES
TO REMAIN
L_
CAP EXISTING
EXHAUST
DUCT
REMOVE EXISTING WATER CLOSET
& CARRIER. REMOVE WASTE PIPE
OR CAP PIPING BELOW FLOOR.
REMOVE VENT PIPING TO FIXTURES
& CAP CONCEALED ABOVE CEILING.
CAP WATER PIPING CONCEALED IN
WALL
INSTALL NEW 4" WALL CLEANOUT &
D_ CONNECT TO EXISTING WASTE PIPE.
CUT & PATCH FLOOR AS REQUIRED
TO CONNECT TO EXISTING WASTE
PIPING.
REMOVE CEILING EXHAUST GRILLE &
BRANCH DUCT. 1 1
EXISTING GRILLE TO REMAIN.
EXISTING FIXTURES TO REMAIN.
EXISTING GRILLE TO REMAIN.
WOMENS RESTROOM DEMOLITION PLAN
SCALE: 1/4" = 1' -0"
-REVIEVVEDFOR
CODE COMPLIANCE
APPROVED
APR 0 2 2010
City of Tukwila
BUILDING DIVISION
RECEIVED
MAR 09 2010
PERMIT CENTER
633 Southcontor Parkway
Tukwila, WA., 98188 -2888
208.2460423
WESTFIELD DESIGN &
CONSTRUCTION
11601 Wilshire Boulevard, 11th Floor
Los Angeles, California 90025 -1748
Telephone 310 478 4456
Facsimile 310 478 4468
IFSIKKOS.
S.M. STEMPER
ARCHITECTS
A MMsNn.I WOW woos owspow
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 08108
0041 11014,-"M • FAX WO -ens
BOGARD ENGINEERS PS
Mechanical Engineering Consultants
22121 17th Avenue SE, Suite 111
Bothell, Woshington 98021
Phone: 425- 415 -6100
Fox: 425- 415 -6117
e -moil: IbogordObogeng.net
WESTFIELD MALL AT SOUTHCENTER
ISSUE
ISSUE
DATE:
0)
z
0
I—
_U
0
0
cz
0
0
w
z
w
w
0
0_
z
z
z
w
PERMIT SET
MAR. 5, 2010
EXPIRES 11/3/11
?tOo3s
PROJECT ARCHITECT
WEJ
PROJECT MANAGER
WEJ
MECHANICAL
LEGEND,
SYMBOLS,
NOTES AND
DEMOLITION
PLAN
M -1
SMSA #: 0915