Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit PG10-036 - TOYS R US / BABIES R US
TOYS R US/BABIES R US 17501 SOUTHCENTERPY PG1 0-036 Parcel No.: Address: Project Name: City oftukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: //www.ci.tukwila.wa.us PLUMBING /GAS PIPING PERMIT 2623049067 17501 SOUTHCENTER PY TUKW TOYS R US / BABIES R US Permit Number: Issue Date: Permit Expires On: PG 10 -036 06/01/2010 11/28/2010 Owner: Name: Address: Contact Person: Name: Address: Email: CLPF-TUICWILA LP C/O JSH PROPERTIES INC , 10655 NE 4TH ST #300 98004 RYAN NOAKES 1811 4 MILE ROAD NE , GRAND RAPIDS MI 49525 NOAKESR @PROGRESSIVEAE.0 OM Contractor: Name: LAKERIDGE PLUMBING & MECH Address: 13508 NE 124 ST , KIRKLAND 98034 Contractor License No: LAKERPM099RK Phone: 616 - 447 -3437 Phone: 425 - 827 -9262 Expiration Date: 05/25/2012 DESCRIPTION OF WORK: THIS IS A TENANT FITOUT. TWO SPACES WILL CONVERT TO SINGLE STORE. WE WILL DEMO TWO EXISTING TOILET GROUPS AND REPLACE WITH A NEW MENS & WOMENS TOILET ROOM AND JC. EXISITING STORM WATER SYSTEM TO REMAIN UNCHANGED. ATTACH TO EXISTING 6" SANITARY SEWER UNDER SLAB. REUSE EXISTING GAS. EXISTING WATER METER & BACKFLOW PREVENTER (PIT) TO BE REUSED. WILL NEED TO DECOMMISION ONE WATER & GAS METER. Value of Plumbing /Gas Piping: Fees Collected: $75,000.00 $616.87 Permit Center Authorized Signature: I hereby ce governin The gran constructio Signature: ify tha I h his wor g of this r the Print Name: Uniform Plumbing Code Edition: 2006 International Fuel Gas Code Edition: 2006 Date: W -1 --tv ead and examined this permit and know the same to be true and correct. All provisions of law and ordinances complied with, whether specified herein or not. does not presume to give authority to violate or cancel the provisions of any other state or loJcal laws regulating ance of work. I am authorized to sign and obtain this plumbing /gas piping permit. Date: r/ This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: UPC -4/10 PG 10 -036 Printed: 06 -01 -2010 • C City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us Parcel No.: 2623049067 Address: Suite No: Tenant: 17501 SOUTHCENTER PY TUKW TOYS R US / BABIES R US PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: PG 10 -036 ISSUED 03/11/2010 06/01/2010 1: ** *PLUMBING AND GAS PIPING * ** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R -3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor /ceiling assemblies and fire - resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. * *continued on next page ** doc: Cond -10/06 PG 10 -036 Printed: 06 -01 -2010 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be compli - • with, whether specified herein or not. does not presume to give authority to violate or cancel the provision of any other work or local laws regulating mance of work. Signature: Print Name: Date: doc: Cond -10/06 PG 10 -036 Printed: 06 -01 -2010 • CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.citukwila.wa.us Building Permit No. Do 6 7,z3 Mechanical. Permit No. tit 1Q_ Q J3 Plumbing/Gas Permit No. 10^ 03 P. Public Works Permit No. Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: 17501 Southcenter Parkway Tenant Name: Toys "R" Us / Babies "R" Us Property Owners Name: JSH Properties, Inc. - John Chelico Mailing Address: 2003 Western Ave, Suite 200 King Co Assessor's Tax No.: )4130 LI — l 0 b 7 Suite Number: 300 Floor: New Tenant: VA Yes ❑..No Seattle WA 98121 City State Zip CONTACT PERSON — who do we contact when your permit is ready to be issued Name: Ryan Noakes PAEP Architecture Engineering, P.C. Mailing Address: 1811 4 Mile Road, NE E -Mail Address: noakesr @progressiveae.com Day Telephone: (616) 447 -3437 Grand Rapids MI 49525 City • State Fax Number: (616) 361 -1493 Zip GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) , y= Company Name: Mailing Address: TBD Contact Person: E -Mail Address: Contractor Registration Number: City Day Telephone: Fax Number: Expiration Date: State Zip ARCHITECT" OF RECORD All plans must be wet stamped by Architect of Record `. Company Name: PAEP Architecture Engineering, P.C. Mailing Address: 1811 4 Mile Road, NE Contact Person: Doug Wuri Grand Rapids MI 49525 E -Mail Address: wurld @progressiveae.com City State Day Telephone: (616) 447 -3439 Fax Number: (616) 361 -1493 Zip ENGINEER OF RECORD — All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: Contact Person: E -Mail Address: Structural Associates, Inc. 62 Commerce Avenue, SW, Suite 100 Grand Rapids MI 49503 Dirk Buttke dbuttke @gowithsai.com H:\Applications\Forms- Applications On Line\2009 Applications \I -2009 - Permit Application.doc Revised: 1 -2009 bh City State Day Telephone: (616) 457 -8100 Fax Number: (616) 457 -8107 Zip Page 1 of 6 .7 1 BUILDING PERMIT INFO ION — 206 -431 -3670 Valuation of Project (contractor's bid price): $ 2,000,000 Existing Building Valuation: $ Scope of Work (please provide detailed information): Renovation of existing (former) Linens & Things and K &G Fashion Superstore, including front elevation modifications and interior renovation (new toilet rooms, offices, break/training room, sales fixtures, finishes, etc.) Will there be new rack storage? ® Yes .. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below Existing Interior Remodel Addition to Existing Structure . New Type of Construction per IBC Type of Occupancy per IBC 1s' Floor 58,132 58,132 0 58,132 IIB Mercantile 2nd Floor ................. . 3 'Floor Floors:. Basement Accessory 'Structure *' Attached Garage Detached Garage. ''Attached Carport Detached Carport Covered Deck :Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: 155 Compact: 131 Handicap: 6 Will there be a change in use? ❑ Yes m No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: m Sprinklers m Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes m No If 'yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11 "paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H: Applications\Foans- Applications On Lme\2009 Applications \1 -2009 - Permit Applicanon.doc Revised: 1 -2009 bh Page 2 of 6 ID MECHANICAL PERMIT INFORMATION - 206 -431 -3670 MECHANICAL CONTRACTOR INFORMATION TBD Company Name: Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Mechanical work (contractor's bid price): $ 100,000 Scope of Work (please provide detailed information): This is a tenant fitout of an existing retail space. Our client will take -over two spaces and combine into one. There are 10 existing RTU's. Of these, one will be abandoned. We will four addtinoal RTU's, all 7.5 tons or smaller. One existing unit heater will remain. We will also add one new 2 -ton ductless split. The building BAS will be upgraded to a new Automated Logic System. Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New .... ® Replacement .... Fuel Type: Electric ❑ Gas ....0 Other: Indicate type of mechanical work being installed and the quantity below: Unit Type: Qty Unit Type: Qty Unit Type :r Qty Boiler /Compressor: Qty BTU Air Handling Unit >10,000 CFM 0 Fire Damper 0 -3 HP /100,000 BTU Furnace>100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Fumace Ventilation Fan Connected to Single Duct Thermostat 13 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Other Mechanical Equipment 1 Air Handling Unit <10,000 CFM 4 Incinerator — Comm/Ind H:\Applications\Fotms- Applications On Line \2009 Applications \1-2009 - Pemut Application.doc Revised: 1 -2009 bh Page 4 of 6 rPLUw11G AND GAS PIPIN RMIT INFORMATION — 206 -431- 0 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: TBD Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Project (contractor's bid price): $ 75,000 Scope of Work (please provide detailed information): This is a tenant fitout. Two spaces will convert to single store. We will demo two existing toilet groups and replace with a new Men's & Women's toilet room and JC. Existing storm water system to remain, unchanged. Attach to existing 6" sanitary sewer under slab. Reuse ex. gas. Existing water meter & backflow preventer (pit) to be reused. Will need to decomision one water & gas meter. Building Use (per Int'1 Building Code): Retail Sales Occupancy (per Int'l Building Code): Mercantile Utility Purveyor: Water: City of Tukwila Sewer: City of Tukwila Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Fixture Type: Qty Fixture Type: Qty Fixture Type:'.: '. Qty Fixture Type: Qty Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) 2 Food -waste grinder, commercial Floor Drain 3 Shower, single head trap Lavatory 6 Wash fountain Receptor, indirect waste Sinks Urinals 2 Water Closet 6 Building sewer and each trailer park sewer Rain water system — per drain (inside building) Water heater and/or vent 1 Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity) Grease interceptor for commercial kitchen ( >750 gallon capacity) Repair or alteration of water piping and/or water treatment equipment 1 Repair or alteration of drainage or vent piping Medical gas piping system serving 1-5 inlets /outlets for a specific gas Each additional medical gas inlets /outlets greater than 5 Backflow protective device other than atmospheric -type vacuum breakers 2 inch (51 turn) diameter or smaller Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Each lawn sprinkler system on any one meter including backflow protection devices Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1 -5) Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Gas piping outlets 4 H:\Applica ions\Fotms- Applications On-Line \2009 Applications \1 -2009 Permit Application.doc Revised: 1 -2009 bh Page 5 of 6 j PERMIT APPLICATION NOTES - Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Pennit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Pennit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWN O TH ZED AGENT: Signature: Date: 03/09/2010 Print Name: Ryan T. Noakes Day Telephone: (616) 447 -3437 Mailing Address: 1811 4 Mile Road, NE Grand Rapids MI 49525 City State Zip Date Application Accepted: 3-11-k0 Date Application Expires: Staff Initials: H:\Applications\Forms- Applications On Line\2009 Applications \1 -2009 - Permit Application.doc Revised: 1 -2009 bh Page 6 of 6 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 2623049067 Address: Suite No: Applicant: TOYS R US / BABIES R US 17501 SOUTHCENTER PY TUKW RECEIPT Permit Number: Status: Applied Date: Issue Date: PG 10 -036 ISSUED 03/11/2010 06/01/2010 Receipt No.: R10 -01319 Initials: LAW User ID: 1632 Payment Amount: Payment Date: Balance: $63.00 07/15/2010 12:39 PM $0.00 Payee: LAKERIDGE PLUMBING & MECHANICAL INC TRANSACTION LIST: Type Method Descriptio Amount Payment Check Authorization No. 25154 63.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts PLUMBING - NONRES 000.322.103.00.00 Total: $63.00 63.00 PAYMENT RECEIVED doc: Receiot -06 Printed: 07 -15 -2010 • • �J�.` wqs City of Tukwila �y Department of Community Development O 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwi la. wa. us RECEIPT Parcel No.: 2623049067 Permit Number: PG 10 -036 Address: 17501 SOUTHCENTER PY TUKW Status: APPROVED Suite No: Applied Date: 03/11/2010 Applicant: TOYS R US / BABIES R US Issue Date: Receipt No.: R10 -00958 Initials: WER User ID: 1655 Payment Amount: $493.50 Payment Date: 06/01/2010 09:07 AM Balance: $0.00 Payee: LAKERIDGE PLUMBING & MECHANICAL INC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 25113 493.50 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts GAS - NONRES PLUMBING - NONRES 000.322.103.00.00 96.60 000.322.103.00.00 396.90 Total: $493.50 PAYMENT RECEIVED doc: Receiot -06 Printed: 06 -01 -2010 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 2623049067 Permit Number: PG 10 -036 Address: 17501 SOUTHCENTER PY TUKW Status: PENDING Suite No: Applied Date: 03/11/2010 Applicant: TOYS R US / BABIES R US Issue Date: Receipt No.: R10 -00433 Initials: User ID: Payee: WER 1655 Payment Amount: $123.37 Payment Date: 03/11/2010 02:18 PM Balance: $493.50 PROGRESSIVE /AE TRANSACTION LIST: Type Method Descriptio Amount Payment Check 38393 123.37 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 123.37 Total: $123.37 PAYMENT RECEIVED doc: Receipt -06 Printed: 03 -11 -2010 \ INSPECTION RECORD Retain a copy with permit p6 to --(9.-?c,„ INSP CTION PERMIT NO.. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -36701 Permit Inspection Request Line (206) 431 -2451 Project: `n) r 4 JS g J Typ of Inspection: 1_ ; "�� p(��1 ate gilled: J�'u" Tel S 64 Address. t r% SL Ql� —l.J Special Instructions: z. A, (0-4 /Co (-y tv7:17.,\ 6 , , z,LD hp /ateWanted:( a.m. Requester: Phone No: Approved per applicable codes. COMMENTS: . J P r. `A (Li �., t ,i Viel ' u-/- ;6c-i f d I p (1,_,A,....& . H ki4 AO k 1 : / . ii. `� Awl i� or _ �,Al G� E�i! /sue. Aire_ e ir- � r er% A, (0-4 /Co (-y tv7:17.,\ 6 , , z,LD hp ..---.. A e 6 n / Inspe , r: .r,A2J Date: n REINSPECTION FEE REQUIRED. Prti'or to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTIO INSPECTION RECORD Retain a copy with permit CI Y OF TUKWILA BUILDING 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 431 -2451 P6f0 -o_3A, PERMIT NO.. DIVISION (206) 431 -3670 Project: Type of Inspection: Address. 111 So I r<< n. Date Cal ed: Special Instructions: J Date Wanted: a.m. Requester: Phone No: 2 - (6() -'7 C3? ❑ Approved per applicable codes. orrections required prior to approval. COMMENTS: , 2 - D Q !- /11l e t t r- e..� r (yam- (4) tN ) A---- 9.,d7 OA Imo' `. F _ -Qr- S ' a V I-LS ( S -Pr —7V \'''A 4 n T tr i\---N ci A- J( k\ ivc--e : 6ce 5 ,-fi T-I'l A A— 6 -� ` .� f 6 )1'‘‘.-44 ‘— V of,-e ms :for: n REINSPE ITC ON FEE REQUIRED. Prior next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Date: INSPECTION NO. INSPECTION RECORD (n Retain a copy with permit ► G �� r PERMIT NO. CITY OF TUKWILA BUILDING DIVISION IZ 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 P ect: Type of 1 1_• : .. Addres 115 s 0) ,S C pAficev Date Called�(v /S C r/ , ,,J 'Cz... -J 4 r Jp.: Special Instructions: (p p DS. De Wanted: 6 -1 ' i v .m. . P.. Requester: _S(1 I dLfW w'\ A 4,f Phorye No:s„ voo _r763 L) n N-T DA r a af a�S r 6 Corrections required prior to approval. 5t COMMENTS: r) n ' n n f6 JAp 'fit , tl SL) 0,("1--- , 1 r s',21_ , ,,J 'Cz... -J 4 r Jp.: (p p DS. _S(1 I dLfW w'\ A 4,f L) n N-T DA r a af a�S r rti) Do L-C j �P, 00 (A.—/_11 (i) :1 A•l a ,AZc—eC—I r-6 a -F 0 r: ( ) ,. ,------\ A a Ins r ector: Date: ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: >s5_ r�1„a� >•�?�ta- s,�:.. •` 4v�'? �."x�,4.�x8�,a-- ,s�,:.ysSf`�RU� - _ : �*,�_ _ _- .,..tea �-, .w�u•_,tsn: INSPECTION NO. INSPECTION RECORD Retain a copy with permit p ,(O,O3 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 \ Project: � ()(JS le- 6A--6 •C s p Type o Insp ecti n: ij X.J ,kg� . J- pLA-,1 Address: riS6 ( p . I A. Date Called. Special Instructions: ree.5 b �) P� / r-, 22'r 4 A 1 p.m. Requester: Phone NoCO _ r7 ' 7 9 / Approved per applicable codes. Corrections required prior to approval. COMMENTS: Z". UJ S.ni-d:,e 2eJ3 ^,mo1 pi pro •/--c ro _ S3 s , gp A 1 Insrector: l Date: 22 0 $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: sz+: asinv4,«111,:.1..at - "AvsnJiSlrSir"!f'` INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 4 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: Ty a of Inspection: Addres I '"l 'Co 1 4-- P Date Called:k Special Instructions: . D e Wanted: / a��„ f `t J p.m. Requester: Phone No: 7,o C4'3 I q_1`1 Rl 0 Approved per applicable codes. 0 Corrections required prior to approval. Z COMMENTS: i r-T A �r p V M ,)„�' pA4/ / '(--t2 f_AfT---/&) 6-rir ()J /-;` i,1A 1( Gaj-, r Date: _ _ f J ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION RECORD Retain a copy with permit INSPECTION O. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., tl 00, Tukwila, WA 98188 (206)431 -3670 PGlu -o3, Project: JC Type of I spection: N.—zS_ S t e Address • / '7 'TO 1 SG ► Date Called: _ (-r ( /0j{/' Special Instructions: i�1\� �J - P0�I JP Date Wanted: .m. (l) p.m. Requester: Phone No:( — J` f 1( 7 o Approved per applicable codes. Corrections required prior to approval. COMMENTS: N.—zS_ S t e r) c-' `I 13 1 _ (-r ( Q _ i�1\� �J - P0�I JP 1p t IS IA-41 6/\ .. r n pc . CAD i cA ib ^ t '\) (\ sir PI i n5 ∎ - /CAN :a..�s t� Date: GI El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: • • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: PG10 -036 DATE: 07/08/10 PROJECT NAME: TOYS R US /BABIES R US SITE ADDRESS: 17501 SOUTHCENTER PY Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # X Revision # 1 after Permit Issued DEPARTMENTS: Iding Division u i Ic V‘411/s44 ors v u Wor s Fire Prevention Structural Planning Division ❑ Permit Coordinator n n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete ❑ Complete IX Comments: DUE DATE: 07 /13/10 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES /THURS ROUTING: Building Please Route REVIEWER'S INITIALS: Structural Review Required n No further Review Required ❑ DATE: APPROVALS OR CORRECTIONS: DUE DATE: 08/10/10 Approved Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: PG10 -036 DATE: 03 -11 -10 PROJECT NAME: TOYS R US / BABIES R US SITE ADDRESS: 17501 SOUTHCENTER PY SUITE 300 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: 4Y- ullding 4t0c of jet_ -(0 Public W rks 3 Fire Prevention Structural Planning Division n Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete n DUE DATE: 03-16-10 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved 1-1 I Approved with Conditions DUE DATE: 04-13-10 Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 PROJECT NAME: 177 c, R/040,,c, ri ERMIT NO: 41/ SITE ADDRESS: i) ORIGINAL ISSUE DATE: ou, [0 I 1,0 REVISION LOG REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS 1 01 k$1 p 1./ EA- J Summary of Revision: vlArp,b, ANri -G l '441( Fra W .. Kith c lc n G -}a 21' Received by: c IA. r ; S `3p-, j „,,‘ e„,v\, REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Web site: http: / /www.ci.tukwila.wa.us REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: —71-7 ft o Plan ChecWPermit Number: PG I — cD ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # Revision # I after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: 1 Li Project Address: j75ot Sow^ t• —'tU Contact Person: ' r �t�"CS�t• ---- —5 Phone Number: ({2c ' �7-'Z �Z Summary of Revision: v � St z-e- Stt-5 -et"' co lo( w'' (`mot- efrY IJUL 0 8 2010 p)l7 CEIYTas Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Entered in Permits Plus on Cfl H:\Applications \Forms- Applications On Linc\2010 Applications \7 -2010 - Rcvision Submittal.doc Crcatcd: 8 -13 -2004 Rcviscd: 7 -2010 Contractors or Tradespeople Pf ter Friendly Page • General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Lakeridge Plumbing & Mech Inc UBI No. 601349575 Phone 4258279262 Status Active Address 13508 Ne 124Th St License No. LAKERPM099RK Suite /Apt. License Type Construction Contractor City Kirkland Effective Date 12/12/1991 State Wa Expiration Date 5/25/2012 Zip 98034 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status LAKERPM1320PLakeridgePlumbing &Amp; Mech Construction Contractor General Unused 9/17/1987 11/23/1992 Archived MERCEIP132J8 Mercer Island Plumbing Construction Contractor General Unused 4/28/1987 11/23/1987 Archived MERCEIP164Q9 Mercer Island Plumbing &Amp; Htg Construction Contractor General Unused 11/29/1984 11/23/1987 Archived ISLANPH169L0 Island Plumbing &Amp; Heating Construction Contractor General Unused 6/20/1984 6/18/1985 Archived EVERGPM066LA Evergreen Plumbing &Amp; Mech Inc Construction Contractor General Unused 6/1/1994 6/1/2006 Expired Business Owner Information Name Role Effective Date Expiration Date Glennon, Anne K &Nbsp; 01/01/1980 Amount Glennon, John P Member 01/01/1980 6802690M475 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 6 CBIC SC7509 05/25/2002 Until Cancelled $12,000.00 04/30/2002 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 13 PHOENIX INS CO 6802690M475 05/25/2010 05/25/2011 $1,000,000.0003 /03/2010 12 PHOENIX INS CO 6802690M475 05/25/2009 05/25/2010 $1,000,000.00 03/31/2009 11 PHOENIX INSURANCE COMPANY 6802690M475 05/25/2008 05/25/2009 $1,000,000.00 06/09/2008 10 ALLIED PROPERTY & CAS INS CO ACP752154878705/25/2004 05/25/2009 $1,000,000.0004 /10/2008 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https://fortress.wa.gov/lni/bbip/Print.aspx 06/01/2010 KEYED NOTES (APPLICABLE TO DRAWINGS P101 THRU P301) se 4 6 8 9 10 I0 ALL ABOVE GRADE PIPING SHALL BE RUN CONCEALED WITHIN THE CEILINGS AND WALLS WHERE HUNG'CEILING IS APPLIED, FLUSH CONTROLS HARD WIRED SENSOR OPERATED. PC SHALL FURNISH AND INSTALL FLUSH VALVE ELECTRICAL BOX MOUNTING KIT TO PROPERLY LOCATED SENSOR AND VALVE ACTUATOR. THE ELECTRICAL CONTRACTOR SHALL INSTALL ELECTRICAL BOXES AND WIRE LOW VOLTAGE POWER FROM PC FURNISHED TRANSFORMER TO EACH VALVE ELECTRICAL BOX, INSTALL PER MANUFACTURERS, INSTRUCTIONS. NO ALTERNATES ALLOWED TO LISTED VALVES. 3/4" VACUUM RELIEF VALVE. WATTS MODEL N -36. TEMPERATURE /PRESSURE RELIEF VALVE WITH NO TRAP IN RELIEF LINE. ROUTE RELIEF LINE FULL SIZE, WITHOUT UPWARD OFFSET, TIGHT TO WALL AND EXPOSED IN THE JANITORS CLOSET TO FLOOR RECEPTOR (FR -1) AND TERMINATE AT 2" ABOVE FLOOD LEVEL OF FR -1. SLOPE HORIZONTAL VENT PIPING FROM STACK AT 1/4" PER FOOT, (MIN. AND TYPICAL). OFFSET VENT STACK AT ROOF TO AVOID ROOF FRAMING, (IF REQUIRED). ALL HOT, TEMPERED AND COLD WATER PIPING SHALL BE INSULATED WITH 1" THICKNESS OF OW ENS CORNING HEAVY DENSITY INSULATION WITH ALL SERVICE JACKET. K = 0.25 AT 100° F MEAN. ABOVE GRADE DOMESTIC COLD WATER PIPING IN SALES, PRE - SALES, AND RECEIVING AREAS SHALL BE ROUTED AS HIGH AS POSSIBLE WITH ALLOWANCE FOR SLOPE AS REQUIRED. 3/4" C.W. DOWN TO HOSE BIBB (HB -1). LOCATE HB -1 AT 12" BELOW BOTTOM OF ROOF DECK ADJACENT TO ROOF ACCESS LADDER, PROVIDE AUXILIARY FRAMING AS REQ'D. TO SECURELY MOUNT HB -1. MOUNT FREEZE -PROOF WALL HYDRANT (WH -1) AT 1' -6" ± ABOVE FINISHED GRADE BUT NOT LOWER THAN 6" A.F.F. COORDINATE EXACT LOCATION AND MOUNTING HEIGHT WITH OWNERS REPRESENTATIVE. PROVIDE 20" X 20" X 9" DEEP GALVANIZED SHEET METAL PAN UNDER HWH -1 WITH 1 1/4" DRAIN PIPE ROUTED TIGHT TO WALL AND EXPOSED IN JANITORS CLOSET TO FLOOR RECEPTOR (FR -1). TERMINATE DRAIN PIPING AT 2" ABOVE FLOOD LEVEL OF FR -1. PLUG TRANSFORMER FOR LAVATORIES AND HARD WIRED TRANSFORMER FOR FLUSH VALVES SHALL BE MOUNTED UNDER TOILET LAVATORY COUNTERTOPS (EC TO PROVIDE OUTLETS /J- BOX). PC TO FURNISH TRANSFORMERS, ONE PLUG TRANSFORMER FOR EACH TOILET ROOM LAVS, AND ONE SINGLE J -BOX MOUNTED TRANSFORMER FOR ALL FLUSH VALVES. EC TO WIRE FLUSH VALVE TRANSFORMER TO SENSOR AND ACTUATOR J- BOXES. ALL SENSOR WIRING SHALL BE CONCEALED, ROUTED ABOVE THE CEILING OR WITHIN WALLS. THE PC SHALL FIELD MEASURE TO DETERMINE LENGTH AND NUMBER OF EXTENSION CABLES. COORDINATE WITH ELECTRICIAN. NOTE: STORAGE RACKS ON 4 -FT. MODULE UNLESS OTHERWISE SHOWN. PRIOR TO ROUGH -IN OF UNDERGROUND SERVICES AND UTILITY RISERS, COORDINATE LOCATIONS OF RISERS WITH FIXTURE PLAN; DWG. RF1, TO MINIMIZE REQUIRED OMISSION OF RACKS AND TO HOLD RACKING MODULE WHERE RACKS MUSTE OMITTED FOR RISERS. (FOR EXAMPLE, RISER WITH TRIM, VALVES, AND ACCESSORIES SHOULD NOT TAK UP THE SPACE OF TWO RACKS IF REQUIRED SPACE IS 4 -FT. OR LESS, AND SO ON). CONTRACTORS SHALL PROVIDE OFFSETS AS REQUIRED IF UNDERGROUND SERVICE IS NOT LOCATED PROPERLY OR IF PROVIDED BY DEVELOPER OR UTILITY COMPANY. NOTE: CONTRACTORS SHALL REFER TO THE FIXTURING PLAN, DRAWING RFt, FOR COORDINATION OF ALL PIPING, EQUIPMENT, DUCTS, VALVING, AND SERVICE RISERS WITH THE OWNERS STORE FIXTURING. ALL SYSTEMS SHALL BE ROUTED AND /OR LOCATED AS REQUIRED TO AVOID INTERFERENCE WITH THE STORE FIXTURES, SHELVING, AND RACKING, INCLUDING THE FUNCTIONAL USE OF SAME. INSTALLATIONS MADE WITHOUT REGARD TO STORE FIXTURING SHALL BE CORRECTED AT NO ADDITIONAL COST TO THE OWNER, SPECIAL CONSIDERATION SHALL BE GIVEN TO THE ESTHETIC INTENT OF THE FRONT GRAPHICS WALL OF THE STORE AND TO THE STORAGE AND MATERIALS HANDLING ASPECTS OF THE PRE -SALES AND RECEIVING DOCK AREAS. UTILITY NOTES: CONTRACTOR SHALL VERIFY POINT OF CONNECTION TO SITE UTILITY SERVICE PRIOR TO COMMENCING INSTALLATION. CONTRACTOR SHALL ADJUST LOCATION AND DEPTH OF BUILDING SERVICES AS REQUIRED TO CONNECT TO SITE UTILITY SERVICE. CONTRACTOR SHALL MAKE FINAL CONNECTION TO SITE UTILITY SERVICE (UNLESS OTHER PROVISIONS HAVE BEEN MADE). CONTRACTOR'S FAILURE TO PROPERLY COORDINATE SERVICES SHALL NOT BE JUSTIFICATION FOR ANY EXTRA CHARGES. BACK -FLOW CERTIFICATION IS REQUIRED BY LOCAL UTILITY FOR CERTIFICATE OF OCCUPANCY. PLUMBING GENERAL DEMOLITION NOTES: 1. CONTRACTORS ARE RESPONSIBLE TO ATTEND PRE -BID WALK THROUGH TO DETERMINE THE EXTENT OF REQUIRED DEMOLITION AND REVIEW EXISTING CONDITIONS. EXISTING PLUMBING DRAWINGS WHERE NOT AVAILABLE FOR THE ENTIRE DEVELOPMENT, THEREFORE LIMITED EXISTING INFORMATION IS AVAILABLE. 2. ALL EXISTING DOMESTIC WATER PIPING NOT BEING REUSED FOR THE NEW TENANT FITOUT SHALL BE REMOVED. REMOVE BACK TO MAINS AND CAP. 3. ALL SANITARY AND VENT PIPING NOT BEING USED BY THE NEW TENANT FITOUT SHALL BE REMOVED. VENT THRU ROOF'S SHALL BE CAPPED ABOVE AND BELOW ROOF. BURIED SANITARY PIPING MAY BE ABANDONED BELOW GRADE OF CAPPED BELOW GRADE AT BOTH ENDS. 4. COORDINATE SIECIFIC DEMOLITION WITH ARCHITECTURAL, MECHANICAL, AND ELECTRICAL TRADES. PROVIDE NOTIFICATION OF DISRUPTION OF EXISTING UTILITIES BEFORE PROCEEDING. 5. ALL EQUIPMENT /FIXTURES LISTED TO BE REMOVED SHALL BE REMOVED FROM THE SITE BY RESPONSIBLE CONTRACTOR. • LOCATION OF REMOVED BREAK ROOM IS IN THIS APPROXIMATE LOCATION (FIELD VERIFY) LOCATION OF REMOVED TOILET ROOMS IS APPROXIMATELY 10' TOWARD THE STORE FRONT FROM THE NEW TOILET ROOMS e • 111 1.. 4 Ir FIELp LOOATE I • i :Y. _h LU Mir T t (4[D NOTE: EXISTING TOILET ROOMS TO BE REPLACED WITH NEW AT SAME GENERAL Ld CATION. THIS CONTRACTOR SHALL. PRO FIXTURES, PIPING & VALVII NEW TOILET ROOMS. THIS IDE ALL NEW G REQUIRED FOR CONTRACTOR SHALL CONNECT TO NEAREST BURIED 4" SANITARY AND 2" OR LARGER DOMESTIC OLD WATER. FIELD VERIFY EXISTING LOCATIONS AND SIZES RTU • co Larik 2E" O EXISTING 6' BURIED SANITARY THAT SERVED MULTIPLE TENANTS. TRU SHALL REUSE EXISTING MAIN FIELD VERIFY EXISTING LOCATION RTU- �i' EtE 0 RTU; _REMOVE 1 -1/4" CW 0 EXISTING FIRE PROTECTIO RISER ROOM AND WATER METER ROOMS TRU SHALL USE LARGER OF TWO DOME TIC WATER FEEDS, WHICH RUNS TO BA K CORNER OF THE STORE, NEAR NEW TOILET ROOMS. THE SECOND SERVICE SHA11L BE CAPPED. EXISTING METER SHALL BE TURNED OVER TO UTILITY Phij- amp a'0 G8 1 EGIE 4 ROUTE TRAPPED DISCHARGE FROM AHU -1 TO CP -1, ROUTE DISCHARGE FROM CP -1 UP THRU ROOF. DISCHARGE THRU GOOSENECK 12" ABOVE ROOF lel IDA LOCATION OF EXISTING BREAK ROOM TO BE REMOVED LOCATION OF EXISTING TOILET ROOMS TO BE REMOVED , AHU -1 (REFER E,.TQ,M201),.....1 NEW SECONDARY CONDENSATE, MOUNT ABOVE CEILING OF EQUIPMENT ROOM REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. PLUMBNG FLOOR PLAN & MECH. DEMO NOTES SCALE = 1 /16" =1' -0" PLUMBING KEYNOTE DEMOLITION NOTES: 0 4 ONE OF TWO EXISTING WATER SERVICES SHALL BE REMOVED. CAP LINE INSIDE NEW RISER ROOM AT FLOOR. COORDINATE REMOVAL OR ABANDONMENT OF EXISTING WATER METER AND BACKFLOW DEVISES WITH WATER UTILITY. METERS ARE LOCATED IN A VALVE PIT OUTSIDE THE BUILDING. THE WATER SERVICE FEEDING THE EXISTING TENANT TOILET ROOM AT THE BACK LEFT OF THE BUILDING (SOUTH -WEST) SHALL BE REUSED. REMOVE ALL DOMESTIC WATER PIPING FROM THE REMOVED SERVICE. THIS FEED AN EXISTING TOILET ROOM AT THE BACK RIGHT OF THE BUILDING (NORTH - WEST). REMOVE ALL TOILET FIXTURES FROM TOILET ROOM GROUP. THIS INCLUDES A MENS & WOMENS TOILET ROOMS AND JANITOR'S CLOSET. REMOVE ALL FIXTURES AND DEVISES (WATER HEATERS, VALVES, ETC...) ALL WATER PIPING TO BE REMOVED. ALL VENT PIPING EXCEPT AS NOTED SHALL BE REMOVED. ALL SANITARY BRANCH LINES SHALL BE REMOVED. CAP WASTE LINES BELOW GRADE, BOTH ENDS. EXISTING 6" BURIED SANITARY LINE TO REMAIN AND BE REUSED FOR NEW TOILET ROOM GROUP. REMOVE ALL FIXTURES AND PIPING ASSOCIATED TO EXISTING BREAK ROOM, AT THIS GENERAL LOCATION. THIS SHOULD BE LIMITED TO A SINGLE COUNTERTOP SINK. HVAC GENERAL DEMOLITION NOTES: 1. CONTRACTORS ARE RESPONSIBLE TO ATTEND PRE -BID WALK THROUGH TO DETERMINE THE EXTENT OF REQUIRED DEMOLITION AND REVIEW EXISTING CONDITIONS. EXISTING HVAC DRAWINGS WHERE NOT AVAILABLE FOR THE ENTIRE DEVELOPMENT, THEREFORE LIMITED EXISTING INFORMATION IS AVAILABLE. 2. WHERE NOTED FOR REMOVAL, DUCTWORK SHALL BE REMOVED BACK TO THE LOCATION SPECIFIED, THE REMAINING DUCTWORK SHALL BE CAPPED AND SEALED AIR - TIGHT. 3 DESIGN INTENT IS FOR ALL EXISTING RTU, EXCEPT FOR RTU -A6, TO BE REUSED. 4. THE RIGHT SIDE RTU'S LABELED AS RTU -A? WERE ORIGINALLY CALLED ACU'S. REFERENCE TAGS IN THE FIELD MAY NOT MATCH THESE CONTRACTOR DOCUMENTS. 5. COORDINATE SPECIFIC DEMOLITION WITH ARCHITECTURAL, MECHANICAL, AND ELECTRICAL TRADES. PROVIDE NOTIFICATION OF DISRUPTION OF EXISTING UTILITIES BEFORE PROCEEDING. 6. ALL EQUIPMENT LISTED TO BE REMOVED SHALL BE REMOVED FROM THE SITE BY RESPONSIBLE CONTRACTOR. 7. EXISTING RTU HVAC CONTROLS WILL BE REPLACED WITH NEW OWNER FURNISHED AUTOMATED LOGIC UNIT CONTROLS. REFER TO DRAWING EMS1 FOR ADDITIONAL INFORMATION. EXISTING THERMOSTATS TO BE REMOVED. PLAN qp, NORTH • 0 0 co 0 REVIEWED FOR CODE COMPLIAN J 2010 Clty UL of 1 Tukw;,la 'BUILD , ; nivisifi FILE CO i Y Permit No.; ?& 10- 03(p PI n review approval is subject to errors and omissions. oval of construction doc m nts does not authorize iolation of any adopt •" de r ordinance. Receipt of approve i - Cop - co d ns is acknowled0efi By ......_.r►1:4`►0iwr.,�,1,,., �■Ir'' - rlr Date: o \0 City Of Tukwila BUILDING DIVISION Nit0 HVAC KEYNOTE DEMOLITION NOTES: as fig EXISTING RTU -A6 SHALL BE ABANDONED IN PLACE. THIS CONTRACTOR SHALL CAP THE EXISTING GAS LINE AFTER EXISTING GAS COCK. COORDINATE WITH ELECTRICAL TRADES-FOR REMOVAL OF ELECTRICAL CONNECTION. REMOVE ALL ASSOCIATED DUCTWORK FROM UNIT, CAP 1' -0" BELOW ROOF DECK. EXISTING RTU TO REMAIN. EXISTING GAS SERVICE TO REMAIN. .., REMOVE EXISTING SUPPLY PLENUM DIFFUSER. RETURN PLENUM TO REMAIN. REMOVE ALL EXISTING SUPPLY AND RETURN DUCTWORK FROM EXISTING UNIT. REFER TO NEW CONSTRUCTION MECHANICAL DRAWINGS FOR NEW DUCTWORK.. REMOVE ALL EXISTING SUPPLY DUCTWORK FROM EXISTING RTU. EXISTING RETURN DUCTWORK/PLENUM TO REMAIN. NOTE THAT THIS UNIT HAS EXTENSIVE LINEAR FEET OF DISTRIBUTION DUCTWORK. REMOVE EXISTING CEILING EXHAUST FANS AND ASSOCIATE DUCTWORK UP TO VENT THROUGH ROOF. REMOVE VENT AND PATCH AND CAP ROOF. COORDINATE WITH ARCH TRADES. IONS I H. L)UL; & HCVISIUNS 1 PLUMBING SYMBOLS AND ABBREVIATIONS LEGEND A.F.F. APPROX. BFP BLDG. C.L. CODP COL, COWP C.W. DIA.;O DN, DOM. DWG. ELC ELECT. EWC FD FIN. FL. FR GCC GPH GPM HAC HB HP H.W. HWH LAV MIN. MFR. MOD. # N.I.C. N.T.S. OD OFL PBC PRESS. P.S.I.;PSI P.S.I.G.;PSIG RD REQ'D. RPZ RWL SAN. SHT. SVC. SYM. TEMP. TP TYP. UR V. RISER V.T.R.F. WC WH XT °F ABOVE FINISHED FLOOR APPROXIMATE BACKFLOW PREVENTER BUILDING CENTERLINE CLEANOUT DECKPLATE COLUMN CLEANOUT WALLPLATE COLD WATER DIAMETER DOWN DOMESTIC DRAWING ELECTRICAL CONTRACTOR ELECTRICAL ELECTRIC WATER COOLER FLOOR DRAIN FINISHED FLOOR FLOOR RECEPTOR GENERAL CONSTRUCTION CONTRACTOR GALLONS PER HOUR GALLONS PER MINUTE HEATING AND AIR COND. CONTRACTOR HOSE BIBB HORSEPOWER HOT WATER HOT WATER HEATER LAVATORY MINIMUM MANUFACTURER MODEL NUMBER NOT IN CONTRACT NOT TO SCALE OVERFLOW ROOF DRAIN OVERFLOW RAINWATER LEADER PLUMBING CONTRACTOR PRESSURE POUNDS PER SQUARE INCH POUNDS PER SQUARE INCH GAUGE ROOF DRAIN REQUIRED REDUCED PRESSURE ZONE BFP RAINWATER LEADER SANITARY SHEET SERVICE SYMMETRICAL TEMPERATURE TRAP PRIMER TYPICAL URINAL VENT RISER VENT THRU ROOF FLASHED WATER CLOSET WALL HYDRANT THERMAL EXPANSION TANK DEGREES FAHRENHEIT VALVE OR SHUT-OFF VALVE O-a GATE --11----..1--- CHECK VALVE GLOBE VALVE D4 PRESSURE REDUCING/REGULATING / VALVE (PRV) FLOOR DRAIN WITH P -TRAP DO CLEANOUT DECKPLATE (CODP) —0 —I CLEANOUT WALLPLATE (COWP) --1- WALL HYDRANT /HOSE BIBB —©-- ROOF DRAIN WITH CLEANOUT UNION I I-- PIPE RISE 10 PIPE DROP -'f -J ® SPRINKLER RISER © WATER METER POINT OF CONNECTION/ ELEVATION /INVERT WATER PIPING — COLD • — .— • HOT WATER PIPING RAINWATER LEADER (RWL) RWL SOIL/SEWER/WASTE PIPING — — — — VENT PIPING PLUMBING FIXTURE OR EQUIPMENT MARK (DESIGNATION FOR SPECIFICATION OR MARK FOR SCHEDULE ON DRAWING) 0 NOTES ON DRAWING AR REVISIONS KEYED NOTES (APPLICABLE TO DRAWINGS P101 THRU P301) se 4 6 8 9 10 I0 ALL ABOVE GRADE PIPING SHALL BE RUN CONCEALED WITHIN THE CEILINGS AND WALLS WHERE HUNG'CEILING IS APPLIED, FLUSH CONTROLS HARD WIRED SENSOR OPERATED. PC SHALL FURNISH AND INSTALL FLUSH VALVE ELECTRICAL BOX MOUNTING KIT TO PROPERLY LOCATED SENSOR AND VALVE ACTUATOR. THE ELECTRICAL CONTRACTOR SHALL INSTALL ELECTRICAL BOXES AND WIRE LOW VOLTAGE POWER FROM PC FURNISHED TRANSFORMER TO EACH VALVE ELECTRICAL BOX, INSTALL PER MANUFACTURERS, INSTRUCTIONS. NO ALTERNATES ALLOWED TO LISTED VALVES. 3/4" VACUUM RELIEF VALVE. WATTS MODEL N -36. TEMPERATURE /PRESSURE RELIEF VALVE WITH NO TRAP IN RELIEF LINE. ROUTE RELIEF LINE FULL SIZE, WITHOUT UPWARD OFFSET, TIGHT TO WALL AND EXPOSED IN THE JANITORS CLOSET TO FLOOR RECEPTOR (FR -1) AND TERMINATE AT 2" ABOVE FLOOD LEVEL OF FR -1. SLOPE HORIZONTAL VENT PIPING FROM STACK AT 1/4" PER FOOT, (MIN. AND TYPICAL). OFFSET VENT STACK AT ROOF TO AVOID ROOF FRAMING, (IF REQUIRED). ALL HOT, TEMPERED AND COLD WATER PIPING SHALL BE INSULATED WITH 1" THICKNESS OF OW ENS CORNING HEAVY DENSITY INSULATION WITH ALL SERVICE JACKET. K = 0.25 AT 100° F MEAN. ABOVE GRADE DOMESTIC COLD WATER PIPING IN SALES, PRE - SALES, AND RECEIVING AREAS SHALL BE ROUTED AS HIGH AS POSSIBLE WITH ALLOWANCE FOR SLOPE AS REQUIRED. 3/4" C.W. DOWN TO HOSE BIBB (HB -1). LOCATE HB -1 AT 12" BELOW BOTTOM OF ROOF DECK ADJACENT TO ROOF ACCESS LADDER, PROVIDE AUXILIARY FRAMING AS REQ'D. TO SECURELY MOUNT HB -1. MOUNT FREEZE -PROOF WALL HYDRANT (WH -1) AT 1' -6" ± ABOVE FINISHED GRADE BUT NOT LOWER THAN 6" A.F.F. COORDINATE EXACT LOCATION AND MOUNTING HEIGHT WITH OWNERS REPRESENTATIVE. PROVIDE 20" X 20" X 9" DEEP GALVANIZED SHEET METAL PAN UNDER HWH -1 WITH 1 1/4" DRAIN PIPE ROUTED TIGHT TO WALL AND EXPOSED IN JANITORS CLOSET TO FLOOR RECEPTOR (FR -1). TERMINATE DRAIN PIPING AT 2" ABOVE FLOOD LEVEL OF FR -1. PLUG TRANSFORMER FOR LAVATORIES AND HARD WIRED TRANSFORMER FOR FLUSH VALVES SHALL BE MOUNTED UNDER TOILET LAVATORY COUNTERTOPS (EC TO PROVIDE OUTLETS /J- BOX). PC TO FURNISH TRANSFORMERS, ONE PLUG TRANSFORMER FOR EACH TOILET ROOM LAVS, AND ONE SINGLE J -BOX MOUNTED TRANSFORMER FOR ALL FLUSH VALVES. EC TO WIRE FLUSH VALVE TRANSFORMER TO SENSOR AND ACTUATOR J- BOXES. ALL SENSOR WIRING SHALL BE CONCEALED, ROUTED ABOVE THE CEILING OR WITHIN WALLS. THE PC SHALL FIELD MEASURE TO DETERMINE LENGTH AND NUMBER OF EXTENSION CABLES. COORDINATE WITH ELECTRICIAN. NOTE: STORAGE RACKS ON 4 -FT. MODULE UNLESS OTHERWISE SHOWN. PRIOR TO ROUGH -IN OF UNDERGROUND SERVICES AND UTILITY RISERS, COORDINATE LOCATIONS OF RISERS WITH FIXTURE PLAN; DWG. RF1, TO MINIMIZE REQUIRED OMISSION OF RACKS AND TO HOLD RACKING MODULE WHERE RACKS MUSTE OMITTED FOR RISERS. (FOR EXAMPLE, RISER WITH TRIM, VALVES, AND ACCESSORIES SHOULD NOT TAK UP THE SPACE OF TWO RACKS IF REQUIRED SPACE IS 4 -FT. OR LESS, AND SO ON). CONTRACTORS SHALL PROVIDE OFFSETS AS REQUIRED IF UNDERGROUND SERVICE IS NOT LOCATED PROPERLY OR IF PROVIDED BY DEVELOPER OR UTILITY COMPANY. NOTE: CONTRACTORS SHALL REFER TO THE FIXTURING PLAN, DRAWING RFt, FOR COORDINATION OF ALL PIPING, EQUIPMENT, DUCTS, VALVING, AND SERVICE RISERS WITH THE OWNERS STORE FIXTURING. ALL SYSTEMS SHALL BE ROUTED AND /OR LOCATED AS REQUIRED TO AVOID INTERFERENCE WITH THE STORE FIXTURES, SHELVING, AND RACKING, INCLUDING THE FUNCTIONAL USE OF SAME. INSTALLATIONS MADE WITHOUT REGARD TO STORE FIXTURING SHALL BE CORRECTED AT NO ADDITIONAL COST TO THE OWNER, SPECIAL CONSIDERATION SHALL BE GIVEN TO THE ESTHETIC INTENT OF THE FRONT GRAPHICS WALL OF THE STORE AND TO THE STORAGE AND MATERIALS HANDLING ASPECTS OF THE PRE -SALES AND RECEIVING DOCK AREAS. UTILITY NOTES: CONTRACTOR SHALL VERIFY POINT OF CONNECTION TO SITE UTILITY SERVICE PRIOR TO COMMENCING INSTALLATION. CONTRACTOR SHALL ADJUST LOCATION AND DEPTH OF BUILDING SERVICES AS REQUIRED TO CONNECT TO SITE UTILITY SERVICE. CONTRACTOR SHALL MAKE FINAL CONNECTION TO SITE UTILITY SERVICE (UNLESS OTHER PROVISIONS HAVE BEEN MADE). CONTRACTOR'S FAILURE TO PROPERLY COORDINATE SERVICES SHALL NOT BE JUSTIFICATION FOR ANY EXTRA CHARGES. BACK -FLOW CERTIFICATION IS REQUIRED BY LOCAL UTILITY FOR CERTIFICATE OF OCCUPANCY. PLUMBING GENERAL DEMOLITION NOTES: 1. CONTRACTORS ARE RESPONSIBLE TO ATTEND PRE -BID WALK THROUGH TO DETERMINE THE EXTENT OF REQUIRED DEMOLITION AND REVIEW EXISTING CONDITIONS. EXISTING PLUMBING DRAWINGS WHERE NOT AVAILABLE FOR THE ENTIRE DEVELOPMENT, THEREFORE LIMITED EXISTING INFORMATION IS AVAILABLE. 2. ALL EXISTING DOMESTIC WATER PIPING NOT BEING REUSED FOR THE NEW TENANT FITOUT SHALL BE REMOVED. REMOVE BACK TO MAINS AND CAP. 3. ALL SANITARY AND VENT PIPING NOT BEING USED BY THE NEW TENANT FITOUT SHALL BE REMOVED. VENT THRU ROOF'S SHALL BE CAPPED ABOVE AND BELOW ROOF. BURIED SANITARY PIPING MAY BE ABANDONED BELOW GRADE OF CAPPED BELOW GRADE AT BOTH ENDS. 4. COORDINATE SIECIFIC DEMOLITION WITH ARCHITECTURAL, MECHANICAL, AND ELECTRICAL TRADES. PROVIDE NOTIFICATION OF DISRUPTION OF EXISTING UTILITIES BEFORE PROCEEDING. 5. ALL EQUIPMENT /FIXTURES LISTED TO BE REMOVED SHALL BE REMOVED FROM THE SITE BY RESPONSIBLE CONTRACTOR. • LOCATION OF REMOVED BREAK ROOM IS IN THIS APPROXIMATE LOCATION (FIELD VERIFY) LOCATION OF REMOVED TOILET ROOMS IS APPROXIMATELY 10' TOWARD THE STORE FRONT FROM THE NEW TOILET ROOMS e • 111 1.. 4 Ir FIELp LOOATE I • i :Y. _h LU Mir T t (4[D NOTE: EXISTING TOILET ROOMS TO BE REPLACED WITH NEW AT SAME GENERAL Ld CATION. THIS CONTRACTOR SHALL. PRO FIXTURES, PIPING & VALVII NEW TOILET ROOMS. THIS IDE ALL NEW G REQUIRED FOR CONTRACTOR SHALL CONNECT TO NEAREST BURIED 4" SANITARY AND 2" OR LARGER DOMESTIC OLD WATER. FIELD VERIFY EXISTING LOCATIONS AND SIZES RTU • co Larik 2E" O EXISTING 6' BURIED SANITARY THAT SERVED MULTIPLE TENANTS. TRU SHALL REUSE EXISTING MAIN FIELD VERIFY EXISTING LOCATION RTU- �i' EtE 0 RTU; _REMOVE 1 -1/4" CW 0 EXISTING FIRE PROTECTIO RISER ROOM AND WATER METER ROOMS TRU SHALL USE LARGER OF TWO DOME TIC WATER FEEDS, WHICH RUNS TO BA K CORNER OF THE STORE, NEAR NEW TOILET ROOMS. THE SECOND SERVICE SHA11L BE CAPPED. EXISTING METER SHALL BE TURNED OVER TO UTILITY Phij- amp a'0 G8 1 EGIE 4 ROUTE TRAPPED DISCHARGE FROM AHU -1 TO CP -1, ROUTE DISCHARGE FROM CP -1 UP THRU ROOF. DISCHARGE THRU GOOSENECK 12" ABOVE ROOF lel IDA LOCATION OF EXISTING BREAK ROOM TO BE REMOVED LOCATION OF EXISTING TOILET ROOMS TO BE REMOVED , AHU -1 (REFER E,.TQ,M201),.....1 NEW SECONDARY CONDENSATE, MOUNT ABOVE CEILING OF EQUIPMENT ROOM REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. PLUMBNG FLOOR PLAN & MECH. DEMO NOTES SCALE = 1 /16" =1' -0" PLUMBING KEYNOTE DEMOLITION NOTES: 0 4 ONE OF TWO EXISTING WATER SERVICES SHALL BE REMOVED. CAP LINE INSIDE NEW RISER ROOM AT FLOOR. COORDINATE REMOVAL OR ABANDONMENT OF EXISTING WATER METER AND BACKFLOW DEVISES WITH WATER UTILITY. METERS ARE LOCATED IN A VALVE PIT OUTSIDE THE BUILDING. THE WATER SERVICE FEEDING THE EXISTING TENANT TOILET ROOM AT THE BACK LEFT OF THE BUILDING (SOUTH -WEST) SHALL BE REUSED. REMOVE ALL DOMESTIC WATER PIPING FROM THE REMOVED SERVICE. THIS FEED AN EXISTING TOILET ROOM AT THE BACK RIGHT OF THE BUILDING (NORTH - WEST). REMOVE ALL TOILET FIXTURES FROM TOILET ROOM GROUP. THIS INCLUDES A MENS & WOMENS TOILET ROOMS AND JANITOR'S CLOSET. REMOVE ALL FIXTURES AND DEVISES (WATER HEATERS, VALVES, ETC...) ALL WATER PIPING TO BE REMOVED. ALL VENT PIPING EXCEPT AS NOTED SHALL BE REMOVED. ALL SANITARY BRANCH LINES SHALL BE REMOVED. CAP WASTE LINES BELOW GRADE, BOTH ENDS. EXISTING 6" BURIED SANITARY LINE TO REMAIN AND BE REUSED FOR NEW TOILET ROOM GROUP. REMOVE ALL FIXTURES AND PIPING ASSOCIATED TO EXISTING BREAK ROOM, AT THIS GENERAL LOCATION. THIS SHOULD BE LIMITED TO A SINGLE COUNTERTOP SINK. HVAC GENERAL DEMOLITION NOTES: 1. CONTRACTORS ARE RESPONSIBLE TO ATTEND PRE -BID WALK THROUGH TO DETERMINE THE EXTENT OF REQUIRED DEMOLITION AND REVIEW EXISTING CONDITIONS. EXISTING HVAC DRAWINGS WHERE NOT AVAILABLE FOR THE ENTIRE DEVELOPMENT, THEREFORE LIMITED EXISTING INFORMATION IS AVAILABLE. 2. WHERE NOTED FOR REMOVAL, DUCTWORK SHALL BE REMOVED BACK TO THE LOCATION SPECIFIED, THE REMAINING DUCTWORK SHALL BE CAPPED AND SEALED AIR - TIGHT. 3 DESIGN INTENT IS FOR ALL EXISTING RTU, EXCEPT FOR RTU -A6, TO BE REUSED. 4. THE RIGHT SIDE RTU'S LABELED AS RTU -A? WERE ORIGINALLY CALLED ACU'S. REFERENCE TAGS IN THE FIELD MAY NOT MATCH THESE CONTRACTOR DOCUMENTS. 5. COORDINATE SPECIFIC DEMOLITION WITH ARCHITECTURAL, MECHANICAL, AND ELECTRICAL TRADES. PROVIDE NOTIFICATION OF DISRUPTION OF EXISTING UTILITIES BEFORE PROCEEDING. 6. ALL EQUIPMENT LISTED TO BE REMOVED SHALL BE REMOVED FROM THE SITE BY RESPONSIBLE CONTRACTOR. 7. EXISTING RTU HVAC CONTROLS WILL BE REPLACED WITH NEW OWNER FURNISHED AUTOMATED LOGIC UNIT CONTROLS. REFER TO DRAWING EMS1 FOR ADDITIONAL INFORMATION. EXISTING THERMOSTATS TO BE REMOVED. PLAN qp, NORTH • 0 0 co 0 REVIEWED FOR CODE COMPLIAN J 2010 Clty UL of 1 Tukw;,la 'BUILD , ; nivisifi FILE CO i Y Permit No.; ?& 10- 03(p PI n review approval is subject to errors and omissions. oval of construction doc m nts does not authorize iolation of any adopt •" de r ordinance. Receipt of approve i - Cop - co d ns is acknowled0efi By ......_.r►1:4`►0iwr.,�,1,,., �■Ir'' - rlr Date: o \0 City Of Tukwila BUILDING DIVISION Nit0 HVAC KEYNOTE DEMOLITION NOTES: as fig EXISTING RTU -A6 SHALL BE ABANDONED IN PLACE. THIS CONTRACTOR SHALL CAP THE EXISTING GAS LINE AFTER EXISTING GAS COCK. COORDINATE WITH ELECTRICAL TRADES-FOR REMOVAL OF ELECTRICAL CONNECTION. REMOVE ALL ASSOCIATED DUCTWORK FROM UNIT, CAP 1' -0" BELOW ROOF DECK. EXISTING RTU TO REMAIN. EXISTING GAS SERVICE TO REMAIN. .., REMOVE EXISTING SUPPLY PLENUM DIFFUSER. RETURN PLENUM TO REMAIN. REMOVE ALL EXISTING SUPPLY AND RETURN DUCTWORK FROM EXISTING UNIT. REFER TO NEW CONSTRUCTION MECHANICAL DRAWINGS FOR NEW DUCTWORK.. REMOVE ALL EXISTING SUPPLY DUCTWORK FROM EXISTING RTU. EXISTING RETURN DUCTWORK/PLENUM TO REMAIN. NOTE THAT THIS UNIT HAS EXTENSIVE LINEAR FEET OF DISTRIBUTION DUCTWORK. REMOVE EXISTING CEILING EXHAUST FANS AND ASSOCIATE DUCTWORK UP TO VENT THROUGH ROOF. REMOVE VENT AND PATCH AND CAP ROOF. COORDINATE WITH ARCH TRADES. IONS I H. L)UL; & HCVISIUNS 1 NO. DATE DESCRIPTION { 1 02/26/10 ISSUED FOR 90% LL REVIEW 03/08/10 t ISSUED FOR BIDS & PERMITS PROTOTYPE UPDATES NO. DATE DESCRIPTION 0 10/28/09 2010 58K REV. 0 1 16I II , ' I II f, BID DATE: 03/09/2010 PROJECT NO.: 55252805 DRAWN BY: RE CHECKED BY: RAF PROTOTYPE DESIGNATION: SSBS 58K PROTOTYPE Ir architecture engineering, P.C. 18114 Mile Rd NE Grand Rapids, MI 49525 www.progressiveae.com ,E11 RECEIV CITY OF TUtwviLA JUL 0 8 2010 .ITCENTER N$L.' _____ _ t; s. rrx s;n STORE SUPPORT ONE GEOFFREY WAYNE, NJ 07470 WAY r —) CENTER THIS DRAWING IS THE EXCLUSIVE PROPERTY OF TOYS "R" US. THE INFORMATION SHOWN MAY NOT BE USED NOR THE DRAWINGS REPRODUCED WITHOUT PERMISSION OF TOYS "R" US. LOCATION TUKWILA., WA DRAWING TITLE PLUMBING . FLOOR PLAN & ME H DEMO SO{ILE 1 /16 = j Q 1 .)E =DAATE MARCH 9, 2010 SHEET NO. PLUMBING SYMBOLS AND ABBREVIATIONS LEGEND A.F.F. APPROX. BFP BLDG. C.L. CODP COL. COWP C.W. D IA.;0 DN. DOM. DWG. ELC ELECT. EWC FD FIN. FL. FR GCC GPH GPM HAC HB HP H.W. HWH LAV MIN. MFR. MOD. # N.I.C. N.T.S. OD OFL PBC PRESS. P.S.I.;PSI P.S.I.G.;PSIG RD REQ'D. RPZ RWL SAN. SHT. SVC. SYM. TEMP. TP TYP. UR V. RISER V.T.R.F. WC WH XT °F ABOVE FINISHED FLOOR APPROXIMATE BACKFLOW PREVENTER BUILDING CENTERLINE CLEANOUT DECKPLATE COLUMN CLEANOUT WALLPLATE COLD WATER DIAMETER DOWN DOMESTIC DRAWING ELECTRICAL CONTRACTOR ELECTRICAL ELECTRIC WATER COOLER FLOOR DRAIN FINISHED FLOOR FLOOR RECEPTOR GENERAL CONSTRUCTION CONTRACTOR GALLONS PER HOUR GALLONS PER MINUTE HEATING AND AIR COND. CONTRACTOR HOSE BIBB HORSEPOWER HOT WATER HOT WATER HEATER LAVATORY MINIMUM MANUFACTURER MODEL NUMBER NOT IN CONTRACT NOT TO SCALE OVERFLOW ROOF DRAIN OVERFLOW RAINWATER LEADER PLUMBING CONTRACTOR PRESSURE POUNDS PER SQUARE INCH POUNDS PER SQUARE INCH GAUGE ROOF DRAIN REQUIRED REDUCED PRESSURE ZONE BFP RAINWATER LEADER SANITARY SHEET SERVICE SYMMETRICAL TEMPERATURE TRAP PRIMER TYPICAL URINAL VENT RISER VENT THRU ROOF FLASHED WATER CLOSET WALL HYDRANT THERMAL EXPANSION TANK DEGREES FAHRENHEIT DES RWL 0 AR GATE VALVE OR SHUT -OFF VALVE CHECK VALVE GLOBE VALVE PRESSURE REDUCING /REGULATING VALVE (PRV) FLOOR DRAIN WITH P -TRAP CLEANOUT DECKPLATE (CODP) CLEANOUT WALLPLATE (COWP) WALL HYDRANT /HOSE BIBB ROOF DRAIN WITH CLEANOUT UNION PIPE RISE PIPE DROP SPRINKLER RISER WATER METER POINT OF CONNECTION / ELEVATION /INVERT COLD WATER PIPING HOT WATER PIPING RAINWATER LEADER (RWL) SOIUSEWER/WASTE PIPING VENT PIPING PLUMBING FIXTURE OR EQUIPMENT MARK (DESIGNATION FOR SPECIFICATION OR MARK FOR SCHEDULE ON DRAWING) NOTES ON DRAWING REVISIONS KEYED NOTES (APPLICABLE TO DRAWINGS P101 THRU P301) 1 U 3 (5) [6) 7 9 10) 11 [12J ALL ABOVE GRADE PIPING SHALL BE RUN CONCEALED WITHIN THE CEILINGS AND WALLS WHERE HUNG CEILING IS APPLIED. FLUSH CONTROLS HARD WIRED SENSOR OPERATED. PC SHALL FURNISH AND INSTALL FLUSH VALVE ELECTRICAL BOX MOUNTING KIT TO PROPERLY LOCATED SENSOR AND VALVE ACTUATOR. THE ELECTRICAL CONTRACTOR SHALL INSTALL ELECTRICAL BOXES AND WIRE LOW VOLTAGE POWER FROM PC FURNISHED TRANSFORMER TO EACH VALVE ELECTRICAL BOX. INSTALL PER MANUFACTURER'S INSTRUCTIONS. NO ALTERNATES ALLOWED TO LISTED VALVES. 3/4" VACUUM RELIEF VALVE. WATTS MODEL N -36. TEMPERATURE /PRESSURE RELIEF VALVE WITH NO TRAP IN RELIEF LINE. ROUTE RELIEF LINE FULL SIZE, WITHOUT UPWARD OFFSET, TIGHT TO WALL AND EXPOSED IN THE JANITOR'S CLOSET TO FLOOR RECEPTOR (FR -1) AND TERMINATE AT 2" ABOVE FLOOD LEVEL OF FR -1. SLOPE HORIZONTAL VENT PIPING FROM STACK AT 1/4" PER FOOT, (MIN. AND TYPICAL). OFFSET VENT STACK AT ROOF TO AVOID ROOF FRAMING, (IF REQUIRED). ALL HOT, TEMPERED AND COLD WATER PIPING SHALL BE INSULATED WITH 1" THICKNESS OF OWENS CORNING HEAVY DENSITY INSULATION WITH ALL SERVICE JACKET. K = 0.25 AT 100° F MEAN. ABOVE GRADE DOMESTIC COLD WATER PIPING IN SALES, PRE - SALES, AND RECEIVING AREAS SHALL BE ROUTED AS HIGH AS POSSIBLE WITH ALLOWANCE FOR SLOPE AS REQUIRED. 3/4" C.W. DOWN TO HOSE BIBB (HB -1). LOCATE HB -1 AT 12" BELOW BOTTOM OF ROOF DECK ADJACENT TO ROOF ACCESS LADDER, PROVIDE AUXILIARY FRAMING AS REQ'D. TO SECURELY MOUNT HB -1. MOUNT FREEZE -PROOF WALL HYDRANT (WH -1) AT 1'-6"± ABOVE FINISHED GRADE BUT NOT LOWER THAN 6" A.F.F. COORDINATE EXACT LOCATION AND MOUNTING HEIGHT WITH OWNERS REPRESENTATIVE. PROVIDE 20" X 20" X 9" DEEP GALVANIZED SHEET METAL PAN UNDER HWH -1 WITH 1 1/4" DRAIN PIPE ROUTED TIGHT TO WALL AND EXPOSED IN JANITOR'S CLOSET TO FLOOR RECEPTOR (FR -1). TERMINATE DRAIN PIPING AT 2" ABOVE FLOOD LEVEL OF FR -1. PLUG TRANSFORMER FOR LAVATORIES AND HARD WIRED TRANSFORMER FOR FLUSH VALVES SHALL BE MOUNTED UNDER TOILET LAVATORY COUNTERTOPS (EC TO PROVIDE OUTLETS /J- BOX). PC TO FURNISH TRANSFORMERS, ONE PLUG TRANSFORMER FOR EACH TOILET ROOM LAVS, AND ONE SINGLE J -BOX MOUNTED TRANSFORMER FOR ALL FLUSH VALVES. EC TO WIRE FLUSH VALVE TRANSFORMER TO SENSOR AND ACTUATOR J- BOXES. ALL SENSOR WIRING SHALL BE CONCEALED, ROUTED ABOVE THE CEILING OR WITHIN WALLS. THE PC SHALL FIELD MEASURE TO DETERMINE LENGTH AND NUMBER OF EXTENSION CABLES. COORDINATE WITH ELECTRICIAN. NOTE: STORAGE RACKS ON 4 -FT. MODULE UNLESS OTHERWISE SHOWN. PRIOR TO ROUGH -IN OF UNDERGROUND SERVICES AND UTILITY RISERS, COORDINATE LOCATIONS OF RISERS WITH FIXTURE PLAN, DWG. RF1, TO MINIMIZE REQUIRED OMISSION OF RACKS AND TO HOLD RACKING MODULE WHERE RACKS MUST BE OMITTED FOR RISERS. (FOR EXAMPLE, RISER WITH TRIM, VALVES, AND ACCESSORIES SHOULD NOT TAKE UP THE SPACE OF TWO RACKS IF REQUIRED SPACE IS 4 -FT. OR LESS, AND SO ON). CONTRACTORS SHALL PROVIDE OFFSETS AS REQUIRED IF UNDERGROUND SERVICE IS NOT LOCATED PROPERLY OR IF PROVIDED BY DEVELOPER OR UTILITY COMPANY. NOTE: CONTRACTORS SHALL REFER TO THE FIXTURING PLAN, DRAWING RF1, FOR COORDINATION OF ALL PIPING, EQUIPMENT, DUCTS, VALVING, AND SERVICE RISERS WITH THE OWNER'S STORE FIXTURING. ALL SYSTEMS SHALL BE ROUTED AND /OR LOCATED AS REQUIRED TO AVOID INTERFERENCE WITH THE STORE FIXTURES, SHELVING, AND RACKING, INCLUDING THE FUNCTIONAL USE OF SAME. INSTALLATIONS MADE WITHOUT REGARD TO STORE FIXTURING SHALL BE CORRECTED AT NO ADDITIONAL COST TO THE OWNER, SPECIAL CONSIDERATION SHALL BE GIVEN TO THE ESTHETIC INTENT OF THE FRONT GRAPHICS WALL OF THE STORE AND TO THE STORAGE AND MATERIALS HANDLING ASPECTS OF THE PRE -SALES AND RECEIVING DOCK AREAS. UTILITY NOTES: CONTRACTOR SHALL VERIFY POINT OF CONNECTION TO SITE UTILITY SERVICE PRIOR TO COMMENCING INSTALLATION. CONTRACTOR SHALL ADJUST LOCATION AND DEPTH OF BUILDING SERVICES AS REQUIRED TO CONNECT TO SITE UTILITY SERVICE. CONTRACTOR SHALL MAKE FINAL CONNECTION TO SITE UTILITY SERVICE (UNLESS OTHER PROVISIONS HAVE BEEN MADE). CONTRACTOR'S FAILURE TO PROPERLY COORDINATE SERVICES SHALL NOT BE JUSTIFICATION FOR ANY EXTRA CHARGES. BACK -FLOW CERTIFICATION IS REQUIRED BY LOCAL UTILITY FOR CERTIFICATE OF OCCUPANCY. PLUMBING GENERAL DEMOLITION NOTES: 1. CONTRACTORS ARE RESPONSIBLE TO ATTEND PRE -BID WALK THROUGH TO DETERMINE THE EXTENT OF REQUIRED DEMOLITION AND REVIEW EXISTING CONDITIONS. EXISTING PLUMBING DRAWINGS WHERE NOT AVAILABLE FOR THE ENTIRE DEVELOPMENT, THEREFORE LIMITED EXISTING INFORMATION IS AVAILABLE. 2. ALL EXISTING DOMESTIC WATER PIPING NOT BEING REUSED FOR THE NEW TENANT FITOUT SHALL BE REMOVED. REMOVE BACK TO MAINS AND CAP. 3. ALL SANITARY AND VENT PIPING NOT BEING USED BY THE NEW TENANT FITOUT SHALL BE REMOVED. VENT THRU ROOF'S SHALL BE CAPPED ABOVE AND BELOW ROOF. BURIED SANITARY PIPING MAY BE ABANDONED BELOW GRADE OF CAPPED BELOW GRADE AT BOTH ENDS. 4. COORDINATE SPECIFIC DEMOLITION WITH ARCHITECTURAL, MECHANICAL, AND ELECTRICAL TRADES. PROVIDE NOTIFICATION OF DISRUPTION OF EXISTING UTILITIES BEFORE PROCEEDING. 5. ALL EQUIPMENT /FIXTURES LISTED TO BE REMOVED SHALL BE REMOVED FROM THE SITE BY RESPONSIBLE CONTRACTOR. NOTE: EXISTING TOILET ROOMS TO BE REPLACED WITH NEW AT SAME GENERAL LOCATION. THIS CONTRACTOR SHALL PROVIDE ALL NEW FIXTURES, PIPING & VALVING REQUIRED FOR NEW TOILET ROOMS. THIS CONTRACTOR SHALL CONNECT TO NEAREST BURIED 4" SANITARY AND 2" OR LARGER DOMESTIC COLD WATER. FIELD VERIFY EXISTING LOCATIONS AND SIZES LOCATION OF REMOVED BREAK ROOM IS IN THIS APPROXIMATE LOCATION (FIELD VERIFY) LOCATION OF REMOVED TOILET ROOMS IS APPROXIMATELY 10' TOWARD THE STORE FRONT FROM THE NEW TOILET ROOMS r" r EXISTING 6" BURIED SANITARY THAT SERVED MULTIPLE TENANTS. TRU SHALL REUSE EXISTING MAIN FIELD VERIFY EXISTING LOCATION RTU LOCATION OF EXISTING BREAK ROOM TO BE REMOVED LOCATION OF EXISTING TOILET ROOMS TO BE REMOVED H REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal acid may include additional plan review fees. REMOVE 1 1/4 G1111 AHU -1 (REFER 0 M201 EXISTING FIRE PROTECTION RISER ROOM AND WATER METER ROOMS TRU SHALL USE LARGER OF TWO DOMESTIC WATER FEEDS, WHICH RUNS TO BACK CORNER OF THE STORE, NEAR NEW TOILET ROOMS. THE SECOND SERVICE SHALL BE CAPPED. EXISTING METER SHALL BE TURNED OVER TO UTILITY b ROUTE TRAPPED DISCHARGE FROM AHU -1 TO CP -1, ROUTE DISCHARGE FROM CP -1 UP THRU ROOF. DISCHARGE THRU GOOSENECK 12 " ABOVE ROOF PLUMBNG FLOOR PLAN & MECH. DEMO NOTES SCALE = 1 /1 6" = 1' -0" PLUMBING KEYNOTE DEMOLITION NOTES: v EI 4 ONE OF TWO EXISTING WATER SERVICES SHALL BE REMOVED. CAP LINE INSIDE NEW RISER ROOM AT FLOOR. COORDINATE REMOVAL OR ABANDONMENT OF EXISTING WATER METER AND BACKFLOW DEVISES WITH WATER UTILITY. METERS ARE LOCATED IN A VALVE PIT OUTSIDE THE BUILDING. THE WATER SERVICE FEEDING THE EXISTING TENANT TOILET ROOM AT THE BACK LEFT OF THE BUILDING (SOUTH -WEST) SHALL BE REUSED. REMOVE ALL DOMESTIC WATER PIPING FROM THE REMOVED SERVICE. THIS FEED AN EXISTING TOILET ROOM AT THE BACK RIGHT OF THE BUILDING (NORTH - WEST). REMOVE ALL TOILET FIXTURES FROM TOILET ROOM GROUP. THIS INCLUDES A MENS & WOMENS TOILET ROOMS AND JANITOR'S CLOSET. REMOVE ALL FIXTURES AND DEVISES (WATER HEATERS, VALVES, ETC...) ALL WATER PIPING TO BE REMOVED. ALL VENT PIPING EXCEPT AS NOTED SHALL BE REMOVED. ALL SANITARY BRANCH LINES SHALL BE REMOVED. CAP WASTE LINES BELOW GRADE, BOTH ENDS. EXISTING 6" BURIED SANITARY LINE TO REMAIN AND BE REUSED FOR NEW TOILET ROOM GROUP. REMOVE ALL FIXTURES AND PIPING ASSOCIATED TO EXISTING BREAK ROOM, AT THIS GENERAL LOCATION. THIS SHOULD BE LIMITED TO A SINGLE COUNTERTOP SINK. HVAC GENERAL DEMOLITION NOTES: 1. CONTRACTORS ARE RESPONSIBLE TO ATTEND PRE -BID WALK THROUGH TO DETERMINE THE EXTENT OF REQUIRED DEMOLITION AND REVIEW EXISTING CONDITIONS. EXISTING HVAC DRAWINGS WHERE NOT AVAILABLE FOR THE ENTIRE DEVELOPMENT, THEREFORE LIMITED EXISTING INFORMATION IS AVAILABLE. 2. WHERE NOTED FOR REMOVAL, DUCTWORK SHALL BE REMOVED BACK TO THE LOCATION SPECIFIED. THE REMAINING DUCTWORK SHALL BE CAPPED AND SEALED AIR - TIGHT. 3. DESIGN INTENT IS FOR ALL EXISTING RTU, EXCEPT FOR RTU -A6, TO BE REUSED. 4. THE RIGHT SIDE RTU'S LABELED AS RTU -A? WERE ORIGINALLY CALLED ACU'S. REFERENCE TAGS IN THE FIELD MAY NOT MATCH THESE CONTRACTOR DOCUMENTS. 5. COORDINATE SPECIFIC DEMOLITION WITH ARCHITECTURAL, MECHANICAL, AND ELECTRICAL TRADES. PROVIDE NOTIFICATION OF DISRUPTION OF EXISTING UTILITIES BEFORE PROCEEDING. 6. ALL EQUIPMENT LISTED TO BE REMOVED SHALL BE REMOVED FROM THE SITE BY RESPONSIBLE CONTRACTOR. 7. EXISTING RTU HVAC CONTROLS WILL BE REPLACED WITH NEW OWNER FURNISHED AUTOMATED LOGIC UNIT CONTROLS. REFER TO DRAWING EMS1 FOR ADDITIONAL INFORMATION. EXISTING THERMOSTATS TO BE REMOVED. NEW SECONDARY CONDENSATE, MOUNT ABOVE CEILING OF EQUIPMENT ROOM CODE �COMPLIANCE APPROVED MAR 2 g 2010 City nr BUILDING DIVISION ECOPY Permit No. Plan review approval is subject to errors and omissions. Approval ofconstru I M ents does not authorize i = . - . ' E r ordi. of the approviolatv gel si ny 'py do =' conditionor s is acknowledgednanceReceipt : City Of Tukwila BUILDING DIVISION HVAC KEYNOTE DEMOLITION NOTES: EXISTING RTU -A6 SHALL BE ABANDONED IN PLACE. THIS CONTRACTOR SHALL CAP THE EXISTING GAS LINE AFTER EXISTING GAS COCK. COORDINATE WITH ELECTRICAL TRADES FOR REMOVAL OF ELECTRICAL CONNECTION. REMOVE ALL ASSOCIATED DUCTWORK FROM UNIT, CAP 1-0" BELOW ROOF DECK. • EXISTING RTU TO REMAIN. EXISTING GAS SERVICE TO REMAIN. REMOVE EXISTING SUPPLY PLENUM DIFFUSER. RETURN PLENUM TO REMAIN. B REMOVE ALL EXISTING SUPPLY AND RETURN DUCTWORK FROM EXISTING UNIT. REFER TO NEW CONSTRUCTION MECHANICAL DRAWINGS FOR NEW DUCTWORK. B REMOVE ALL EXISTING SUPPLY DUCTWORK FROM EXISTING RTU. EXISTING RETURN DUCTWORK/PLENUM TO REMAIN. NOTE THAT THIS UNIT HAS EXTENSIVE LINEAR FEET OF DISTRIBUTION DUCTWORK. REMOVE EXISTING CEILING EXHAUST FANS AND ASSOCIATE DUCTWORK UP TO VENT THROUGH ROOF. REMOVE VENT AND PATCH AND CAP ROOF. COORDINATE WITH ARCH TRADES. RECEIVED PG CO `43 ip PERMITCENTER CONSTR. DOC & REVISIONS NO. DATE 02/26/10 03/08/10 DESCRIPTION ISSUED FOR 90% LL REVIEW ISSUED FOR BIDS & PERMITS PROTOTYPE UPDATES NO. DATE DESCRIPTION 0 10/28/09 2010 58K REV. 0 BID DATE: 03/09/2010 PROJECT NO.: 55252805 DRAWN BY: BJP CHECKED BY: RAF PROTOTYPE DESIGNATION: SSBS 58K PROTOTYPE architecture engineering, P.C. 1811 4 Mile Rd NE Grand Rapids, Mi 49525 www.progressiveae.com STORE SUPPORT CENTER ONE GEOFFREY WAY WAYNE, NJ 07470 THIS DRAWING IS THE EXCLUSIVE PROPERTY OF TOYS "R" US. THE INFORMATION SHOWN MAY NOT BE USED NOR THE DRAWINGS REPRODUCED WITHOUT PERMISSION OF TOYS "R" US. LOCATION TUKWILA. WA DRAWING TITLE PLUMBING FLOOR PLAN & MECH DEMO SCALE 1 /1 6" = 1' -0" ISSUE DATE MARCH 9, 2010 SHEET NO. P101 OJ 1-1/2"V 1 1/4"V FROM UR (TYP. OF 2) 1-1/2"V FROM „ 3" WALL CO SANITARY PIPING SCHEMATIC 1:.)20:y SCALE = NTS WOMEN'S ROOM SW.MMX HALL Orr '); PLUMBING SECTION AT TOILET ROOMS SCALE = 1/4" = 1'-0" 3/4" P&T RELIEF VENT LINE FROM EWH41 DOWN TO FR-1, DISHCARGE WITH:2" AIR GAS ABC:iVE FLOOD PLAIN OF FIXTURE I 3"CO 3"WCO •" FROM WATER HEATER DRAIN PAN, ROUTE TO WITH 2" AIR GAP A6OVE FLOOD PLAIN OF FIXTURE FT: 3"o 1/2"o 1 1 12e 1 1/4"o 3"o —COMMON-VENT LINETN ''' PLUMBING-CHASE 4"o 4" WASTE LINE UP „ INTO CHASE TO FEED n; LAVS, UR'S AND WC'S ...... ............. — 3"VS, OFFSET 3'-0" AT ROOF DECK FROM EDGE OF BUILDING TO 4"VTRF CONNECT NEW 4" SANITARY TO EXISTING MAIN. FIELD VERIFY 1 1 ; NOTES: ( * REFER TO DRAIN, WASTE AND VENT PIPING DIAGRAM, THIS SHEET. de, OFTPLAINLILm6u"mAND LARGER SAN. SEWER PIPING BELOW FLOOR AT 1/4"/FT MINIMUM, AND ALL 4" AND SMALLER PIPE AT * PBC SHALL FILL FLOOR DRAIN P-TRAP WITH WATER UPON COMPLETION OF ALL WORK AND TESTING (TYP. ALL FLOOR DRAINS). * INSULATE ALL EXPOSED PIPING BELOW LAVS (L-1) AND SINKS (S-1). * PBC SHALL USE FIXTURE CARRIER WITH AUXILIARY 2" WASTE TAP FOR WATER CLOSET BACK TO BACK WITH URINAL. PROVIDE SEPARATE VENTS. * DESIGN BASED ON VENT PIPING TO BE ROUTED IN CHASE. ALL HORIZONTAL BRANCH VENTS SHALL BE A MINIMUM OF 6" ABOVE FLOOD PLAIN OF HIGHEST FIXTURE. ENLARGED TOILET AREA SANITARY PLAN SCALE = 1/4" = 1'-0" /- EX. 4" BURIED (FIELD VERIFY) SANITARY MAIN NORTH 2"of 2"CW UP IN JOIST SPACE, ROUTE NEAREST 2"CW OR LARGER (FROM REMOVED TOILET ROOMS IN SAME GENERAL AREA) 2"CW DOWN FROM JOIST SPACE TO ABOVE HALL CEILING 3/4"CW 1/2"CW TO TRAP PRIMER 1"CW EWH-1, MOUNT ON SHELF DRAIN PAN 3/4"H&CW TO EWH 3/4"H&CW TO FR-1 FAUCET (WITH VB) 2"CW DN. IN TOILET ROOM CHASE FR-1 .. 3/4"CW TO WC'S (TYPICAL) NOTE: PROVIDE BALL VALVES AT ALL BRANCH LINES (OUTSIDE OF CHASE) 1"CW To.WC'S,...„ (TYPICAL) WALL FLUSH MOUNT SENSOR (TYP.) WC-VALVE ACTUATOR, WALL FLUSH MOUNT (TYP.) BELOW SLAB TRAP PRIMER LINE (TYP OF 2) NOTE: P.C. SHALL PROVIDE WATER HAMMER ARRESTORS FOR ALL FEEDS TO WC'S, UR'S, LAVS AND SINKS, CW, HW & TW, PER PDI-2006-WH2O1 DOMESTIC WATER PIPING SCHEMATIC SCALE = NTS ROUTE TRAP PRIMER TUBING IN CHASE OR BELOW 3/4"H&CW TO EWH 3/4"H&CW TO SERVICE SINK FAUCET ROOM 122 • CONNECT 1/2"CW OFF LINETO FR-1 FAUCET FOR FD TRApPRIMER 3/4"o 11 11 2"o 2' of WOMEN'S ROOM 123 2"CW DN IN CHASE BREAK ROOM 118 3/4" THERMOSTATIC-. MIXING VALVE . SEr OUTLET TO 105 DEGREE F. \;.;›, 3/4"H&CW TO BREAK ROOM SINK SENSOR FLUS VALVES & LAV FAUCET TRANSORMER, BELOW COUNTER 1/2"TW TO EACH LAV. HALL 113 tf-2 • MOTHER'S 2"0 ROOM (TYP.) 124 ..•.......••••••..,..•••.. •••• NOTES: MOUNT TO - -- UNDERSIDE OF COUNTER (HIDE FROM VIEW) * REFER TO WATER PIPING SCHEMATIC, THIS SHEET. * REFER TO DETAILS ON DRAWING P301 AND SPECIFICATIONS FOR VALVE REQUIREMENTS. * TRAP PRIMERS FOR FLOOR DRAINS SHALL BE LOCATED IN ACCESSIBLE LOCATION. 2" C.W. SUPPLY. CONNECT TO NEAREST 2"CW OR LARGER. EXISTING TOILET ROOM WAS LOCATED AT THIS APPROXIMATE LOCATION. (FIELD VERIFY) * REFER TO ARCHITECTURAL DRAWINGS FOR PLUMBING FIXTURE MOUNTING REQUIREMENTS. ALL BARRIER FREE FIXTURES SHALL COMPLY WITH FEDERAL ADA REGULATIONS AND LOCAL REQUIREMENTS. * TOILET ROOM LAVATORIES ARE PROVIDED BY THE G.C. FAUCET AND PLUMBING IS PROVIDED BY P.C. * NEW FLUSH VALVES SHALL BE HARD WIRED AUTOMATIC SENSOR VALVES. ALL WIRING SHALL BE HIDDEN FROM VIEW. THE SINGLE TRANSFORMER SHALL BE MOUNTED BELOW THE LAV COUNTERTOP. CONTRACTOR SHALL USE SLOAN ELECTRICAL BOX/FLUSH VALVE MOUNTING POSITIONING KITS TO VERIFY CORRECT INSTALLATION REQUIREMENTS. ALL LOW VOLT WIRING FOR THE FLUSH VALVES SHALL BE BY THE ELECTRICAL CONTRACTOR WITH ELECTRICAL BOX POSITIONING KITS INSTALLED BY THE PC * ALL PIPING FOR TOILET LAVS SHALL BE HIDDEN BEHIND THE ARCH PROVIDED SHROUD. * ALL LAVATORIES SHALL HAVE HARD WIRED SENSOR FAUCETS. ALL LOW VOLT WIRING FOR LAVATORIES SHALL BE BY THE PLUMBING CONTRACTOR. A PLUG TRANSFORMER SHALL BE MOUNTED UNDER THE LAV COUNTERTOP FOR EACH TOILET ROOM. THE PC SHALL PROVIDE ALL NECESSARY EXTENSION CABLES (SLOAN MODEL EAF-17-A, 25-A & 24-A) AND SPLITTER CABLES AS REQUIRED (FIELD VERIFY). ALL WIRING SHALL BE CONCEALED BEHIND LAV SHROUD OR WITHIN WALLS. TOILET AREA WATER PIPING PLAN SCALE = 1/4" = 1'-0" PLAN NORTH REVIEWED FOR CODE COMPLIANCE APPROVED MAR 2 6 2010 City of Tukwila BUILDING DIVISION RECEIVED MAR 1 1 2010 PERMIT CENTER CONSTR. DOC & REVISIONS DATE DESCRIPTION 02/26/10 ISSUED FOR 90% LL REVIEW 03/08/10 ISSUED FOR BIDS & PERMITS PROTOTYPE UPDATES NO. DATE DESCRIPTION 0 10/28/09 2010 58K REV. 0 BID DATE: 03/09/2010 PROJECT NO.: 55252805 DRAWN BY: BJP CHECKED BY- RAF PROTOTYPE DESIGNATION: SSBS 58K PROTOTYPE architecture engineering, P.C. 1811 4 Mile: Rd NE Grand Mi 49525 www.progressiveae.com STORE SUPPORT CENTER ONE GEOFFREY WAY WAYNE, NJ 07470 THIS DRAWING IS THE EXCLUSIVE PROPERTY OF TOYS "R" US. THE INFORMATION SHOWN MAY NOT BE USED NOR THE DRAWINGS REPRODUCED WITHOUT PERMISSION OF TOYS "R" US. LOCATION TUKWILA, WA ClAENLARGED VINGTLE PLUMBING PLANS & SCHEMATICS SCALE 1/4" =1-0" ISSUE DATE MARCH 9, 2010 SHEET NO. P201 A9 1 1/4" 0 STEEL CABLE. INSTALL TO BE TAUT, WITHIN 1/30F ENDS. INSTALL LOWER CABLE 4" MIN. ABOVE CONTROLS. 7' -0" (MIN.) A.F.F. 1 1/2" X 1 1/2" X 1/8" ALL - WELDED STEEL ANGLE MOUNTING SHELF PRIMED AND PAINTED WHITE GLOSS ENAMEL. (SQUARE SHELF) WATER HEATER DIA. +3" (MIN.) Ank w 3/4" PLYWOOD (4)ANGLES 1/4" 0 EYE BOLT TO WATER HEATER SUPPORT FRAMING. • 0„K N 30 SECURELY ANCHOR TO WALL STUDS W /MIN. OF FOUR (4)1/4" DIA. STEEL FASTENERS. (2) VERTICAL & (2) DIAGONAL ANGLES. 16 WATER HEATER MOUNTING SHELF DETAIL ."301 y SCALE = 12 1' -0" CW, SEE PLAN - THERMOMETER O, 3 /4 "TW (105 °F) , .. 3/4" WATTS MMV LOCATE IN ACCESSIBLE LOCATION c5 EXPANSION TANK, AMTROL MODEL ST -5 �- 3/4" CW 3/4" HOT WATER (125°F) DIELECTRIC UNIONS (TYP.) HEAT TRAP CONNECTORS BALL VALVE (TYP.) - WATER HEATER SUPPORTING SHELF, SEE DETAIL THIS SHEET RELIEF VALVE TO SERVICE SINK (INDIRECT) 3/4" DRAIN DN TO SERVICE SINK (INDIRECT) 10 WATER HEATER CONNECTION DETAIL P301 / SCALE = 12 = 1' -0" OVERSIZED HANGER PIPE INSULATION PIPE GALVANIZED STEEL INSULATION SHIELD INSERT (TYPICAL) 1 COLD WATER HANGER DETAIL P301 SCALE = 12" = 1' -0" PLUMBING FIXTURE FIXTURE MARK MANUFACTURER SERIES NUMBER WATER CLOSET AND URINAL ACCESSORIES AND FEATURES BOWL TYPE OUTLET FLUSH VALVE SEAT CARRIER ® AMERICAN STANDARD 2257.103 WALL MOUNT ELONGATED SIPHON JET BOTTOM SLOAN ROYAL OPTIMA 111 ES -S AM. STD 5901.100 OPEN FRONT WADE 300 SERIES ADJUSTABLE 1.6 GPM. ELECTRICALLY WIRED SENSOR FLUSHMETER. VALVE SHALL BE PROVIDED WITH OVER -RIDE BUTTON, ONE EL -154 TRANSFORMER (FOR ALL FLUSH VALVES), AND EL -485 -A ELECTRICAL BOX POSITIONING KIT, INSTALL PER MFG. INSTRUCTIONS. v ® AMERICAN STANDARD 2257.103 WALL MOUNT ELONGATED SIPHON JET BOTTOM SLOAN ROYAL OPTIMA 111 ES -S AM. STD. 5901.100 OPEN FRONT WADE 300 SERIES ADJUSTABLE SAME FIXTURE AND ACCESSORIES AS WC -1, BUT MOUNT PER ADA BARRIER FREE REQUIREMENTS. UR AMERICAN STANDARD 6541.132 WALL -HUNG WASH OUT BACK SLOAN ROYAL OPTIMA 186- 0.5 ES -S -OR WADE 400 SERIES LOW FLOW FIXTURE, 0.5 GPM. ADA FIXTURE, INSTALL PER MFG. INSTRUCTIONS. ELECTRICALLY WIRED SENSOR FLUSHMETER. PROVIDE VALVE WITH MANUAL OVER -RIDE BUTTON, VALVE SHALL BE PROVIDED WITH EL -485 -A ELECTRICAL BOX POSITIONING KIT, UR AMERICAN STANDARD 6541.132 WALL -HUNG WASH OUT BACK SLOAN ROYAL OPTIMA 186- 0.5 ES -S -OR WADE 400 SERIES SAME FIXTURE AND ACCESSORIES AS UR -1, BUT MOUNT PER ADA BARRIER FREE REQUIREMENTS. © FIXTURE MARK MANUFACTURER SERIES NUMBER LAVATORY/SINK ACCESSORIES AND FEATURES BOWL TYPE FAUCET SUPPLY PIPE TRAP Alk SOLID SURFACE PROVIDED BY G.C. BY OTHERS SLOAN, ADA MODEL EAF 100 FLEX WITH ANGLE STOP CHROME PLATED BRASS COUNTERTOP LAV BY OTHERS. SENSOR OPERATED FAUCET SHALL BE ADA COMPLIANT, WIRED BACK TO TRANSFORMER, MODEL EAF -11, PROVIDE WITH EXTENSION CABLES AND SPLITTER CABLES (EAF -23 -1 & EAF -25 -A) ® © ELKAY ELUHD2115 UNDERMOUNT 21 "x15.75 "x5" CHICAGO FAUCET 786 GN2 FC FLEX WITH ANGLE STOP CHROME PLATED BRASS UNDERMOUNT!SINK, INSTALLED PER MFG INSTRUCTIONS.; SINGLE BLOW - ADA COMPLIANT. FAUCET WITH LEVER TYPE HANDLE AND 1.0 AERATOR. SINGLE BOWL ADA COMPLIANT, 18 GA., TYPE 302 VW FIXTURE MARK MANUFACTURER SERIES NUMBER FLOOR RECEPTOR ACCESSORIES AND FEATURES BOWL TYPE FAUCET TRAP AL FIAT SB -3624 PRECAST TERRAZZO AMER. STD. 8340.243 CAST IRON REMOVABLE CHROME PLATED BRASS STRAINER PLATE. ® FIXTURE MARK MANUFACTURER SERIES NUMBER + FLOOR DRAIN /STRAINER ACCESSORIES AND FEATURES MATERIAL TYPE SIZE FREE AREA MATERIAL FD JOSAM 30003 -6A CAST IRON 6A 3 "o /6 "ra 11 SQ. IN BUFF POLISHED BRONZE TWO PIECE BODY, DOUBLE DRAINAGE FLANGE, WEEP HOLES WITH DEEP SEAL P -TRAP AND TRAP PRIMER. v FIXTURE MARK MANUFACTURER SERIES NUMBER WATER HEATER ACCESSORIES AND FEATURES GAL. CAPACITY TYPE # ELEMENTS WATTS VOLTS /o AIM A.O. SMITH EJCS -20 19 ELECTRIC 1 5500 277/1 MOUNT ON SHELF PER DETAIL THIS SHEET WHERE SHOWN. SET TEMP. CONTROL AT 135 °F. PROVIDE WATTS MODEL #100XL TEMP. /PRESS. RELIEF VALVE. VW FIXTURE MARK MANUFACTURER SERIES NUMBER ELECT. WATER COOLER ACCESSORIES AND FEATURES CAPACITY VOLTS HP FINISH `nk HALSEY TAYLOR HAC8 FSBL Q ADA SS 8 GPH 120 1/5 STANDARD NO ALTERNATES: BI LEVEL ELECTRIC WATER COOLER. INSTALL PER A.D.A. REFER BI -LEVEL ELEC. WATER COOLER ELEV. & ROUGH -IN DETAIL THIS SHEET. THE ENTIRE UNIT INCLUDING THE CASING /CABINET SHALL BE STAINLESS STEEL. ® FIXTURE MARK MANUFACTURER SERIES NUMBER WALL HYDRANT ACCESSORIES AND FEATURES HYDRANT CASING BOX TYPE WEIGHT ® JOSAM 71050-8 BRONZE BRONZE NIKALOY NON- FREEZE 7 LBS PROVIDE WITH WALL CLAMP, UNION ELBOW ASSEMBLY AND SELF - OPENING, VANDAL -PROOF SATIN FINISH FACE COVER. ® FIXTURE MARK MANUFACTURER SERIES NUMBER HOSE BI BB ACCESSORIES AND FEATURES BODY HANDWHEEL HOSE END CONNECTION WEIGHT HB WATTS SC8 4 CAST BRASS CAST IRON 3/4" I.P. REGULAR PATTERN 1/2 LBS. PROVIDE WITH TAMPER PROOF VACUUM BREAKER. FIXTURE MARK MANUFACTURER SERIES NUMBER TRAP PRIMER ACCESSORIES AND FEATURES MODEL NO NO. OF DRAINS TP PRECISION PLUMBING PRODUCTS, INC. P1 -500 SEE PLANS MUST BE INSTALLED WITH ACCESS FOR PERIODIC INSPECTION NOTES: 1. ALL NOTED FIXTURES SHALL BE ACCESSIBLE TO INDIVIDUALS WITH DISABILITIES IN ACCORDANCE WITH THE "AMERICANS WITH DISABILITIES ACT OF 1990 ". FIXTURES AND THEIR INSTALLATION SHALL ALSO COMPLY WITH AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI) PUBLICATION A117.1 - "PROVIDING ACCESSIBILITY AND USABILITY FOR PHYSICALLY HANDICAPPED PEOPLE" AND /OR GOVERNING CODE. 2 ALL PLUMBING FIXTURES, EQUIPMENT, TRIM, AND FITTINGS SHALL COMPLY WITH LOCAL, STATE, AND FEDERAL REGULATIONS AND CODES, INCLUDING, BUT NOT LIMITED TO WATER AND ENERGY CONSERVATION CODES. THE SCHEDULED AND /OR SPECIFIED PLUMBING FIXTURES AND EQUIPMENT REPRESENT THE MINIMUM CRITERIA AND SHALL BE THE BASIS FOR THE CONTRACTOR'S BASE BID. IF THE SCHEDULED OR SPECIFIED FIXTURES OR EQUIPMENT DO NOT COMPLY WITH GOVERNING CODES OR REGULATIONS IN ALL RESPECTS, THE CONTRACTOR SHALL PROVIDE AN ALTERNATE BID FOR COMPLYING FIXTURES, EQUIPMENT, TRIM, OR FITTINGS. THE ABSENCE OF AN ALTERNATE BID SHALL BE CONSTRUED TO MEAN THAT THE CONTRACTOR'S BID INCLUDES ALL COSTS NECESSARY TO MEET ALL REGULATIONS AND CODES. CONDENSATE PUMP SCHEDULE TAG MARK MANUFACTURER MODEL SHUT -OFF HEAD SIZE MOTOR POWER REMARKS LITTLE GIANT VCMA -20 20' 1/2 GAL. 1/30 HP 120V/1/60 SECONDARY CONDENSATE PUMP, MOUNT ABOVE CLG, HEAVY DUTY CLEANOUT 24 "x 24 "x 6" CONCRETE PAD EXCEPT IN CONCRETE PAVEMENT DIAMETER RISER 1/8 BEND 7- SOIL PIPE "Y" BRANCH UG IF END OF PIPE YARD CLEANOUT FINISHED FLOOR rz/- IH /// -- COVER REFER TO SPECIFICATIONS ADJUSTABLE HOUSING GASKETED CLEANOUT PLUG CI, PVC OR ABS CLEANOUT WASTE LINE LENGTH TO SUIT 7 STANDARD CLEANOUT DETAILS P301 SCALE = 12" = 1' -0" WASTE LINE FLOOR CLEANOUT WWI MAY EXTEND AS WASTE OR VENT FOR WALL CONST. REF TO ARCH DWGS CLEANOUT PLUG COUNTERSUNK SCREW —�� POLISHED S.S. OR CHROME ACCESS COVER 7A A d C.I. CLEANOUT TEE WASTE LINE, LENGTH TO SUIT 1/8 BEND @a END OF LINE CLEANOUT WASTE LINE WALL CLEANOUT CHROME PLATED ESCUTCHEON AT WALL. TEE 3" (TYP.) 18- 1/16" (TYP.) WALL 1/2" S.O.V. 7-1/2" (TYP. & SYM.) 6 -3/8" (TYP. & SYM.) 18" (TYP.) 37-1/8" 3/8" WATER SUPPLY BY PBC. 1" (TYP. & SYM.) 1" (TYP. & SYM.) 1 -1/2" IPS WASTE BY PBC. SUPPLY HEADER IN WALL TRAP PRIMER VALVE WITH INTEGRAL BACKFLOW PREVENTER AND VACUUM BREAKER PORT. PRECISION PLUMBING PRODUCTS MODEL P1 -500. 7 -1/4" 7" (TYP.) 11 -1/2" 4 -1/2" 2 -3/4" 2-1/2" (TYP.) DISTRIBUTION UNIT REQ'D FOR MULTIPLE TRAP CONNECTIONS. 6- 5/16" 3-1/2" SECURE DISTRIBUTION UNIT TO BACKING SHEET BETWEEN STUDS. 1/2" COPPER TUBING TRAP SUPPLIES, ROUTE BELOW FLOOR TO FLOOR DRAIN TRAPS SEE PLAN. i TRAP PRIMER DETAIL SCALE = 12" = 1' -0" ELECTRICAL SUPPLY 3- WIRE RECESSED BOX. FIN. FLOOR w w 0 w O N d) bo N co 18 -5/8" (TYP.) 16" (TYP 1 1/4" DRAIN & PIPING BY MFR. (TYP. OF 2). N. N HANGER BRACKET (TYP.) 3/8" TUBING SERVICE STOP WATER SUPPLY BY PBC. 1-1/2" P -TRAP & TRAP ARM BY PBC. REVIEWED FO CODE COMPLIAN APPROVED MAR 2 6 2010 6 -13/1 10 -5/8" (FYP.) NOTES: 1. REFER TO ARCH. DWGS. FOR REQUIRED SUPPORT FRAMING. 2. ROUGH -IN DIMENSIONS SHOWN ARE SUBJECT TO CHANGE BY HALSEY TAYLOR WITHOUT NOTIFICATION. CONTRACTORS RELYING ON ROUGH -IN DIMENSIONS SHOWN WITHOUT VERIFICATION FROM MANUFACTURER'S DATA SHALL DO SO AT THEIR OWN RISK AND TO DO SO WILL NOT BE CONSIDERED JUST CAUSE FOR ADDITIONAL COMPENSATION. 2 WATER COOLER ROUGH -IN DETAIL P301 SCALE = 12" = 1' -0" City of Tukwila BUILD DIVISIO RECEIVED MAR 112010 PERMIT CENTER CONSTR. DOC & REVISIONS NO. DATE DESCRIPTION 02/26/10 ISSUED FOR 90% LL REVIEW 03/08/10 ISSUED FOR BIDS & PERMITS PROTOTYPE UPDATES NO. DATE DESCRIPTION 10/28/09 2010 58K REV. 0 BID DATE: 03/09/2010 PROJECT NO.: 55252805 DRAWN BY: BJP CHECKED BY: RAF PROTOTYPE DESIGNATION: SSBS 58K PROTOTYPE architecture engineering, P.C. 18114 Mile Rd NE Grand Rapids, Mi 49525 www.progressiveae.com STORE SUPPORT CENTER ONE GEOFFREY WAY WAYNE, NJ 07470 THIS DRAWING IS THE EXCLUSIVE PROPERTY OF TOYS "R" US. THE INFORMATION SHOWN MAY NOT BE USED NOR THE DRAWINGS REPRODUCED WITHOUT PERMISSION OF TOYS "R" US. LOCATION TUKWILA, WA DRAWING TITLE PLUMBING SCHED AND DETAILS SCALE 12" = 1' -0" ISSUE DATE MARCH 9, 2010 SHEET NO. P301 /\R i