Loading...
HomeMy WebLinkAboutPermit PG10-083 - NEW SYSTEMS LAUNDRYNEW SYSTEMS LAUNDRY 12608 INTERURBAN AV S PG1 0-083 City oilI'ukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.ci.tukwila.wa.us PLUMBING /GAS PIPING PERMIT Parcel No.: 0004800003 Address: 12608 INTERURBAN AV S TUKW Project Name: NEW SYSTEMS LAUNDRY Permit Number: PG10 -083 Issue Date: 07/22/2010 Permit Expires On: 01/18/2011 Owner: Name: GATEWAY OLYMPIA INC Address: PO BOX 4900 #207 , SCOTTSDALE AZ 85261 Contact Person: Name: BUD KLOSTERMAN Address: 8706 S 222 ST , KENT WA 98031 Email: BUD @STATEMECH.NET Contractor: Name: STATE MECHANICAL COMPANY Address: 600 INDUSTRY DR 8 , TUKWILA WA 98188 Contractor License No: STATEMC141C7 Phone: 206 - 575 -7527 Phone: Expiration Date: 09/01/2011 DESCRIPTION OF WORK: INSTALL NEW 1 WATER CLOSET AND 1 LAVATORY ON MODIFIED ROUGH -INS. NO NEW FIXTURES Value of Plumbing /Gas Piping: $800.00 Fees Collected: Permit Center Authorized Signature: Uniform Plumbing Code Edition: 2009 $34.13 International Fuel Gas Code Edition: 2009 Date: -3—)-4)- ° I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this plumbing /gas piping permit. Signature: Date: Print Name: „ cJ P k ��.5� Vim► / lJ This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: UPC -4/10 PG 10 -083 Printed: 07 -22 -2010 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tulcwila.wa.us Parcel No.: 0004800003 Address: Suite No: Tenant: 12608 INTERURBAN AV S TUKW NEW SYSTEMS LAUNDRY PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: PG 10 -083 ISSUED 07/15/2010 07/22/2010 1: ** *PLUMBING AND GAS PIPING * ** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R -3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor /ceiling assemblies and fire - resistance rated walls or partitions shall be protected m accordance with the requirements of the building code. 11: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures and fittings in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use significant quantities of water shall comply with Washington States Water Efficiency and Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 402 of Washington State Amendments. 12: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 13: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. * *continued on next page ** doc: Cond -10/06 PG 10 -083 Printed: 07 -22 -2010 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Signature: ' Print Name: Date: 7-2,7(‘) ordinances governing or local laws regulating doc: Cond -10/06 PG10 -083 Printed: 07 -22 -2010 CITY OF TUKWILIP Community Development Department Public Work Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Building Permit No. Mechanical Permit No. Plumbing /Gas Permit No.N, (a-- a 93 Public Works Permit No. Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION King Co Assessor's Tax No.: 000 Li O 3 Site Address: (24 0' TN.) 're e. uK.ISAIJ Ale S. Suite Number: (20 % A N Ew Si s T E/vls 1-44.) N D CY New Tenant: [/ Yes ❑ ..No Tenant Name: Property Owners Name: Mailing Address: Zip City State CONTACT PERSON - who do we contact when your permit is ready to be issued Name: r--tJ'17 f Day Telephone: 9.-0Co - 5 %5- 76-27 Mailing Address: 70 CQ S 5 (thAn ¥ C P Q ( gn 3 ' ^ `� City State Zip E -Mail Address: VJ V ck C 5 1 L !J`"� VOQC h ' lkih Fax Number: 2062 - 575 - 7Z9 GENERAL CONTRACTOR INFORMATION - (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: 5T6-T4 I' l 6-c 1- fr})J (G L. Mailing Address: t;,p S 2 i `" Contact Person: tJD KA-os f iQ1 1Af1 \ E -Mail Address: , > ✓D e_9 v4 n Contractor Registration Number: L57_fT P1 C ((4 ( c ' t f4gtex;.- w� c Q3J State City Zip Day Telephone: 2 %, -575 -752:7 Fax Number: 20Cn - 575 - 7 5 z-49 Expiration Date: -1 / ( / (' ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: Mailing Address: Zip Contact Person: E -Mail Address: City Day Telephone: Fax Number: State ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: Zip Contact Person: E -Mail Address: Q:Wpplications Po ms- Applications On tine\3 -2006 - Permit Application.doc Revised: 9 -2006 bh City Day Telephone: Fax Number: State Page 1 of 6 PLUMBING AND GAS PIPINGTPERMIT INFORMATION - 206 - 431 -3670 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: .57-A, J 6- 74 c —c(4411f / -L Mailing Address: g fro 5 2_2 Z- 57- Contact Person: 11-C,051-1 RN E -Mail Address: 1/47uccl� 8-4ri.4ee∎A .Gk - Contractor Registration Number: ST/} / C.. /11 c (Li( 0-4 1- OA- 96-03/ City State -7 Zip Day Telephone: 20Ca- 5 %i5 - ! 527 Fax Number: 2C9 Co - 575 " 75 27 Expiration Date: R/ ( / 1 Valuation of Plumbing work (contractor's bid price): $ gce Valuation of Gas Piping work (contractor's bid price): $ Scope of Work (please provide detailed information): 4 . ••■..As C (osek a..0 1 LeoltiotAi rt,r Ovl 00 ,tJ Fw f -T 12 mock 1 rove h 1r . Building Use (per Int'l Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: Sewer: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath/shower Drinking fountain or water cooler (per head) Wash fountain Gas piping outlets Bidet Food -waste grinder, commercial Receptor, indirect waste Clothes washer, domestic Floor drain Sinks t1 Dental unit, cuspidor Shower, single head trap Urinals Dishwasher, domestic, with independent drain Lavatory Water Closet 5 `�'( Building sewer or trailer park sewer Rain water system - per drain (inside building) Water heater and/or vent Additional medical gas inlets/outlets - six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or alteration of water piping and/or water treating equipment I Repair or alteration of drainage or vent piping I Medical gas piping system serving one to five inlets/outlets for specific gas Q:1Applications\Forms- Applications On Line \3-2006 - Permit Application.doc Revised: 9 -2006 nh Page 5 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUQ.DING��R AUTHAGENT: Signature. - i -e4 Print Name: 1'7u D (61-0S72:4,n1 A IJ Mailing Address: cb7o C0 $ ZZZNDST , Date: 7 ► `1 l ! c Day Telephone: 2 Oro - g 75 — /S 2.77 City State Zip Date Application Accepted: �.... -' Date Application Expires: I ' i� / 61 Staff Initials: 1..V 1 Q: tApplications\Forms- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh Page 6 of 6 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tu/cwila.wa.us RECEIPT Parcel No.: 0004800003 Permit Number: PG 10 -083 Address: 12608 INTERURBAN AV S TUKW Status: PENDING Suite No: Applied Date: 07/15/2010 Applicant: NEW SYSTEMS LAUNDRY Issue Date: Receipt No.: R10 -01321 Initials: User ID: Payee: WER 1655 Payment Amount: $34.13 Payment Date: 07/15 /2010 02:01 PM Balance: $0.00 STATE MECHANICAL CO TRANSACTION LIST: Type Method Descriptio Amount Payment Check 27929 34.13 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES PLUMBING - NONRES 000.345.830 6.83 000.322.103.00.00 27.30 Total: $34.13 doc: Receiot -06 Printed: 07 -15 -2010 INSP.Eef1ON NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit PERMIT NO. (206)431 -3670 Pro ect: Type of Inspecti n: Ili Address: i ?.CP 0 f fir! .e-a rb., Date Called: Special Instructions: Date Wanted: CJ r a.m. Requester: Phone o: ` $ 73" —75 Zr Approved per applicable codes. Corrections required prior to approval. COMMENTS: PO4- f'. ,0 1 Th Datexi ri $6i.00 REINSPECTION FE REQUIRED. Prior to inspection, fee must be p d at 6300 Southcenter lvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: <. ---1c ..'3_'k- .1.-._ ........-.�s�.__..'..«,- .x..31. -._.� .,1.. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION e- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Pam' -off . Project: /(/f "cJ 6?-45 if/r1 S Type of Inspection: /)/) /(6/ —; N ,ilcrn.5 Address: A2 G OR _1.o /e -/ t /b/,u Date Cala �rou i�.1 v ( k Special Instructions: .ii. Date Wanted: .) 2 3 / O p.m. Requester: Phone No: (-96 — 7 /c°— r 3.0•5 Approved per applicable codes. Corrections required prior to approval. 2.1/ COMMENTS: Inspeor: Dater , ■3 _._(J ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: • P ,.., a T a? G COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: PG10 -083 DATE: 07 -15 -10 PROJECT NAME: NEW SYSTEMS LAUNDRY SITE ADDRESS: 12608 INTERURBAN AV S X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: AtOc 'uildi- ng Division 4v/A Public Works Fire Prevention Structural n Planning Division n n Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete n DUE DATE: 07 -20-10 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route Structural Review Required nNo further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 08 -17 -10 Approved Approved with Conditions JJ Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 Contractors or Tradespeople Peer Friendly Page • General /Specialty Contractor A business registered as a construction contractor with LEI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name STATE MECHANICAL COMPANY UBI No. 600611697 Phone 2065757527 Status Active Address 600 Industry Dr 8 License No. STATEMC141C7 Suite /Apt. License Type Construction Contractor City Tukwila Effective Date 2/27/1986 State WA Expiration Date 9/1/2011 Zip 98188 Suspend Date County King Specialty 1 Plumbing Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status DESIGM'110NQDESIGN MECHANICAL Construction Contractor Boiler /Steam Fit /Proc Piping plumbing 8/18/1989 8/17/1993 Archived RXHCO "121NARX11 COMPANY Construction Contractor Plumbing g oiler /Steam Fit /Proc Piping 8/1/1988 7/27/1999 Archived GERRICI163B3 GERRIK COMPANY INC Construction Contractor General Unused 1/23/1984 1/9/1991 Archived Business Owner Information Name Role Effective Date Expiration Date PLATZ, GREG D Cancel Date 01/01/1980 Amount DEWITT, RALPH E 20 01/01/1980 GL1650261 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 3 TRAVELERS CAS E SURETY CO 200686359 07/27/2001 Until Cancelled $6,000.00 08/14/2001 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 20 COLONY INS CO GL1650261 06/02/2008 06/02/2011 $1,000,000.0005 /06/2010 19 FIRST MERCURY INS CO FMFL001801 06/02/2006 06/02/2008 $1,000,000.00 05/09/2007 18 NORTH AMERICAN CAPACITY PNG100046600 06/02/2006 06/02/2007 $1,000,000.00 05/25/2006 17 CO LEXINGTON INS 1143373 A 06/02/2004 06/02/2006 $1,000,000.0005 /19/2005 16 MA CAS CFP23233506 09/01/2003 09/01/2004 $1,000,000.00 08/11/2003 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https://fortress.wa.gov/lni/bbip/Print.aspx 07/22/2010 ROOM SCHEDULE ROOM 'I - FLOOR: NEW CARPET BASE: NEW 4" RUBBER BASE WALL: GYP. BD. (PANTED) (EE) CEILING: SUSPENDED ACOUSTICAL ( +VAFF) ROOM '1 - FLOOR: NEW SHEET VINYL FLOORING (REMOVE EX.) BASE: NEW 6" COVED SHT. VINYL BASE WALL: WANSCOT 4' PLASTIC LAM. (REMOVE EX) WALL: GYP. BD. (PANTED) (SGE) CEILING: GYP BD. REPAINT, PAINT NEW ( +91AFF) WALL TYPES ES [-] EXISTING CONCRETE WALL FURRED W/ 5/8" GYP. BD. OVER STEEL STUDS e 24" 0.C. . • R -19 BATT NSULATION. U =0.062 I " 16" X 10 GA STEEL STUDS e 24" O.C. W GYB. BD. 80TH SIDES TO 10' APR„ PROVIDE DIAGONAL STEEL STUD BRACE TO ADJACENT WALLS MAX. a 8' 0.C. SEE DETAILS. R -19 BATT INSULATION. U =0.061 rq6" X 20 GA STEEL STUDS • 24" O.C. W 5/8" GYP BD. EACH SIDE, VAPOR BARRIER (WATER PROOF GYP BD. INSIDE) STEEL STUD BRACE TO ADJACENT WALLS MAX. • 8' O.C. SEE DETAILS. R -19 BATT INSULATION. U =0.062 MATCH STUDS TO EX. FRAMNG DOOR SCHEDULE (LEVER HANDLES) (MATCH EX. DOORS AND FRAMES) DOOR Et : EXISTING DOOR CHANGE TO ADA LEVER HANDLES DOOR E2 : EXISTING OVERHEAD DOOR, CHANGE HEIGHT TO II' -6" DOOR 2 : NEW •3' X T S.C. WOOD DOOR WOOD JAMB, 1-1/2 PAIR BUTTS, PRIVACY LOCK, WALL STOP, CLOSER DOORS 1: NEW 3' X 1' S.C. WOOD DOOR WOOD JAMB ,1 -I/2 PAIR BUTTS, WALL STOP, LOCKSET, WEATHERSTRIPPING, THRESHOLD LEGEND DUPLEX OUTLET LL TELEPHNOE OUTLET AND DATA, MUDRNG, CONDUIT AND FULL STRING 1 POLE LIGHT SWITCH RECESSED 2X4 -3 TUBE, T -8 FLUORESCENT 88 WATTS LIGHT FIXTURE FIXTURE W/ ACRYLIC LENSES TO MATCH EX. TOTAL PROPOSED WATTAGE = 116 WATTS TOTAL ALLOWABLE WATTAGE = I WATT / SP. X 189 SR. = 189 WATTS IN ADDITION, REMOVED WATTAGE IS GREATER THAN NEW NSTALLED WATTAGE GENERAL NOTE5 L NEW OFFICE AREA TO BE PROVIDE WITH ELECTRIC WALL I4EATER AND WINDOW VENTILATION 1. PATCH, REPAIR, 4 PANT EXTERIOR WALLS 4 DOOM. 3. REFURBISH EXISTING RESTROOM, PATCH, REPAIR 4 PANT GYP. BD. WALLS 4 CEILING, INSTALL NEW TOILET, SINS, P. LAM. WAINSCOT, SHEET VINYL FLOORING, 4 COVED SHEET BASE. 4. EXISTING UNIT HEATERS, REPLACE UNITS AS REQUIRED. MAX 8 BTU / HR FOR FREEZE PROTECTION. 5. INSTALL NEW CARPET, BLINDS, AND WALL HEATERS N EX. OFFICES. M FAINT EX. AND NEW OFFICES. 6. ADD NEW WALL NEATER ON BACK WALL CF OFFICE 1. ADD NEW FS 25 WHITE VNLY FACING OVER EX. INSULATION N WAREHOUSE 8. PATCH APPROX 5 TO 1 HOLES N WAREHOUSE DRYWALL t INSTALL TWO ADDITIONAL EXTERIOR LIGHTS CN BACK WALL OF BUILDING 10. REPLACE EX. WATER HEATER AND EX. EXHAUST FAN IN RESTROOM STEEL. STUD BRACE e 8'- 0" O.C. TO ADJACENT WALLS 101.011 R -30 BATT INSULATION R -19 BATT NSULATION 6 1'X20 GA. STEEL STUDS e 24" 0.C. 5/8" GYP. 8D. INTERIOR WALL HEAD DETAIL SCALE:1 1/2" : 1' -0" STUD WALL (SEE SCHEDULE) 1x WOOD BLOCKING 2 V2" WOOD CASING - PANTED 1 1/2" x WOOD JAMB PANTED 5/8" x WOOD STOP PANTED SOLID CORE WOOD DOOR PANTED 5/8" GYP BD. EACH SIDE DOORS AND FRAMES TO MATCH EXISTING WOOD FRAME DETAIL SCALE: I -1/2" = 1' -0" 6'X(20 GA. STEEL STUDS e 24" O.C. NEW 5/8" GYP. BD. ON 6" X 10 GA. METAL CEILING JOISTS AT MAX. 24" O.C. NSTALL R -30 INSULATION ON CEILING 60" NO 24" 18' C4 REMOVE EX. OVERHEAD FLUORESCENT FIXTURES ABOVE CEILING AREAS (2 e 1T X 8' • 132 WATTS X 2 • 264 WATTS) INSTALL TWO NEW FLUORESCENT FIXT. = 1'16 WATTS GRAB BAR 5' DIA. TURNNG RADIUS 8" WALL 2 -11/2" STL. STUDS RESTROOM I/4 " =i' -0" -1' -3" CLEAR 6 "X20 GA. STEEL TRACK ATTACH BOTTOM TRACK TO CONC. FLOOR W/ POWDER DRIVEN HILTI ANCHORS 1" EMBEDMENT AT 24" O.C. 4. 4 5/8" GYP BD. EXIST. CONC. SLAB ON GRADE INTERIOR UJALL SILL DETAIL SCALE :11/2" : 1' -0" SECTION INSULATION 1/2" GYP. BD. OR CEILING TILES BRACED OR STRAPPED TOGETHER TO PROVIDE AIR TIGHT ENCLOSURE W/N ULATION ABOVE - STEEL STUD FRAMNG AS REQUIRED EX. SUSP. CLG NO CHANGES 0 0 EX SUS? CLG NO CHANGES NEW 2X4' SUSPENDED ACOUSTICAL e 9' -0" AFF, SEE SEISMIC NOTES. R -30 NSULATION ON CEILING, TENT FIXTURES RELOCATE EX. LIGHT FIXTURE ABOVE SINK OR REPLACE AND MATCH WATTAGE REPLACE EX. EXHAUST FAN AND 140T WATER TANK EX. WAREHOUSE NO CHANGE TO ENVELOPE & NEW LIGHTING NOT TO EXCEED 0.5 WATTS / S.F. 50' -0" REFLECTED CEILING PLAN 1/8 " =11 -0" PRISMATIC LENSED FLUORESCENT FIXTURE FOR RECESSED LIGHTS IN AN INSULATED SUSPENDED CEILNGS LIGHT FIXTURE PROTECTION SCALE: 1 -1/2" = 1' -0" GR66 R IVZ MAN RIMER A CEILING 10 G P To Dell ANGLE (MOLLDNG) AT TWWO ADJACENT WALLS VA POP RIVET& 4 a Gil WIRES NU1HN 2' OF CRoee TEE n ARRANGED AT Ha EACH 01108 AND AT AN ANGLE NOT EXC13<DNG 46: LOCATE RESTRAINT PANELS AT D' OD N EACH DIREC DI AND HUM IN b' CF EACH TALL NATAURAL VENTILATION: PER 1203.4 PROVIDE MIN. 4% OF FLOOR AREA M NATURAL VENTILATION (189 SF X .64 = 1.6 'SF) REPLACE EX. SINGLE PANE WINDOW WITH NEW INSULATED WINDOW (MN U= 0.40 WITH S145C 0. 040) OPERABLE FOR NATURAL VENTILATION 1.6 SF. WITH SCREEN ON NSIDE, AWNING OUT. 111-I0" 12' -11" 0 ADJACENT SPACE IS OFFICE AND IS HEATED FURR OUT WALL COLUMN TO BE PLUSH INSIDE RR A EX. OFFICE 159 SPA OCC. EX. OPEN OFFICE B 11 -3" 1_ REBU • EX. BATHROOM ROM SUSPENSION WIRES TO BE Q GAM AT 4' OD. LV ATTAa1'ENT DEVICES CAPABLE Cf SIJ°PORTNG I¢m POIJDS HANGER 1 PERIMETER UM MUST EE AIM LIMN T N 6 KEGS GOWER SLOP, WNFES ARE PROVIDED )k 1) MAN 13EN 9 TEES AND MI6 TEES MUST EE IEAW DUTY IP COM830TILTN 8111TIG1146 Of 180 POUNDS N carreee1ON . TN3BIGN. 2) alum AREAS GREATER NAM ITT00 EP MAT LATERAL IVRCE D vt4 DIA AG 441. MAY E R.4 H3 SNRES, LIMIRO MOVEMENT TO LESS IRAN V4' AT POINT OF ATTACRTE 3) LIGHT FDOURES TO EE FONTIVE . r ATTACTED TO MAN AND CROW TEES. AND F OVER Mt MOT OE RDEPED9rTLY SUPPORTED. 4) PARTmm101, GREATER 1HLN4 6' TALL NEB SIMPER:9D MGM VIA MAY UM (SEPARATE FROM ANT OTHER WIRES). PARTI1104S 6' OR LEN NO ATIAG41E0 I6 TWINED. 6) SPR SCLER IEAD PENETRATION, MUST HAVE 2' OVERSIZED 1RM TO ALLOW 1' M01,43134t N ALL INFECTIONS. 6) MAM.FAGTUFER GERM/CATION OF carom' FEFf01FM4iNCE AID PERIODIC SPEC: 4 . NSPEC110N OF ANCINOR eTSTtli b REWIRED.. 1) FOR GELNG AREAS F> DING 300 SF, A 6E18MIG SEFERATION JOINT OR FULL MIGHT WALL PARTITION 114AT ORE TIE MI6 SHALL OE PROVIDED. 6) ALL Ga^66 TEES SHALL DE CAPABLE OF CARRTIG NE DESIGN LOAD WNW' E)KEiDNG IEFLEGTICN EOIIAL lei 1. aF rTb SPAN 3) ALL WIRE TES ME TO EE THREE tag MINS AROUD ITSELF WM 3 NO1. °RERUNS) CEILING DETAILS as IBC 2003 etc 1621 AND CISCA 3 -4 AS111 C63S AS111 0636 ASCE 1 -02) 0 DA STANDARDS Ell NOTE: PROVI E SIGNAGE ON WALLS OP 0 STORAGE ABOVE" EX. WAREHOUSE 4,312 S.P. 8 OCCUPANTS NOTE: ADD PS 25 WHITE VINYL PACING OVER EX. ROOF INSULATION EXISTING DEMISING WALL EXISTING TILT UP WALL INCREASE DOOR HEIGHT FROM 10' TO 1I' -6 ", NEW DOORS TO BE 10'11J X 11' -6" TALL, WEATHERSTRIP EE: STRUCTURAL EXISTING CONCRETE WALL 50' -0" NORTN ADD TWO EXT. LIGHTS FLOOR PLAN °titRcE FILING To OCCUPANT LOAD: OFFICE = 653 SF.= 65 OCC WISE =4 ,312 SP.. OCC TOTAL OCCUPANT LOAD 15 .COOL FX P1rrmit No. Fi COPY 610-0 3 Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the viola on of any adopted code or ordinance. Receipt of approti ed Field Copy and conditions is acknowledged° By Date: 77"2--2-A0 / City Of Tukwila BUILDING DIVISION REVVED FO`. COMPLI' .‘ICE • 2010 ADD DOOR SWEEP AND WEATHERSTRIP 1/8 " =1' -0" SEPARATE PERMIT REQUIRED FOR: ,,©./Mechanical is Electrical ❑ Plumbing t Gas Piping City of Tukwila BUUU.5)ING DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. JUN ; o TUIE Lis ILDING AREA OF WORK UNDER THIS PERMIT NORTW KEY PLAN REVIEWED FOR CODE COMPLIANCE APPRMED JUL 2 1 2010 City of Tukwila BUILDING DIVISION Gioo83 N.T.S. TEN AN T SPACE UNDER THIS PERMIT RECEIVED JUL 15 2010 PERMIT CENTER RECEIVED CITY OF TUKWILA MAY 262010 PERMIT CENTER W 0 0 61 0 r 4 0 DESCRIPTION w 1 0) (0 00 03 V) (0 N 0 0 N (\1 w 0 x �u- z to f— WO >Z� �Q tY Z LLj O c0 Q (!) Cr) "gasp L,Jcoa) .2 1 w rTh Z r:9 1-4 H T -1 \ \Wkst -4 \documents \CAD\2002 \0225 RREEFLTenant Improvements \Tukwila Commerce Park\BLDG A\12608 SUITE 120,NEWSTYSTEMS\TI.dwg, 5/24/2010 11:47:01 AM, Designlet 500 MAIN.pc3