Loading...
HomeMy WebLinkAboutPermit PG10-086 - US BANKUS BANK 151 ANDOVER PK E PG1 0-086 Parcel No.: Address: City oikukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http. //www.ci.tukwila.wa.us PLUMBING /GAS PIPING PERMIT 0223100038 151 ANDOVER PK E TUKW Project Name: US BANK Permit Number: Issue Date: Permit Expires On: PG 10 -086 08/04/2010 01/31/2011 Owner: Name: Address: Contact Person: Name: Address: Email: Contractor: Name: Address: Contractor U S BANK CORPORATE PROPS 2800 E LAKE ST , LAKE0012 55406 JOFFRE SECHIER 6802 S 220 ST , KENT WA 98032 JOFFRE @C OMFORTMECH. C OM COMFORT MECHANICAL INC 6617 S 193 PL, #P -105 , KENT, WA 98032 License No: COMFOMI015LA Phone: 425 - 251 -9840 Phone: 425 - 251 -9840 Expiration Date: 06/01/2012 DESCRIPTION OF WORK: REISSUE OF EXPIRED PERMIT PG09 -134: INSTALL 1 1/2" GALVANIZED PIPE TO NEW ROOFTOP UNIT Value of Plumbing /Gas Piping: Fees Collected: Permit Center Authorized Signature: $1,250.00 $63.00 Uniform Plumbing Code Edition: 2009 International Fuel Gas Code Edition: 2009 Date: V- 1 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be - = mplied with, whether specified herein or not. The granting of this p mit • •es not presume to give authority to violate or cancel the provisions of any other state or local laws regulating ance of yvorJa. Jam authorized to sign and obtain this plumbing /gas piping permit construction or the p Signature: Print Name: Date: This permit shall become null and void"if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: UPC -4/10 PG10 -086 Printed: 08 -04 -2010 • �J,�,�►a wqs City of Tukwila Parcel No.: Address: Suite No: Tenant: Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 0223100038 151 ANDOVER PK E TUKW US BANK PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: PG 10 -086 ISSUED 07/21/2010 08/04/2010 1: ** *PLUMBING AND GAS PIPING * ** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R -3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor /ceiling assemblies and fire - resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. * *continued on next page ** doc: Cond -10/06 PG 10 -086 Printed: 08 -04 -2010 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this per - does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the p= o ance of work. Signature: Print Name: Date: ,g //1 doc: Cond -10/06 PG10 -086 Printed: 08 -04 -2010 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto://www.cLtukwila.wa.us Plumbing /Gas Permit No. 1)6 0— 0 U f ProjectNo. (For office use only) PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION King Co Assessor's Tax No.: 0223100038 Site Address: 151 ANDOVER PK ili�6 Tenant Name: US BANK Property Owners Name: US BANK CORPORATE PROPERTIES Mailing Address: 2800 EAST LAKE ST. Suite Number: Floor: New Tenant: ❑ Yes ..No City State Zip CONTACT PERSON - Who do we contact when your permit is ready to be issued Name: JOFFRE SECHIER Mailing Address: 6802 S. 220TH ST. E -Mail Address: joffre@comfortmech.com Day Telephone: KENT (425) 251 -9840 WA City State Fax Number: (425) 251 -9871 98032 Zip PLUMBING' / GAS PIPING' CONTRACTOR INFORMATION Company Name: COMFORT MECHANICAL Mailing Address: 6802 S. 220TH ST Contact Person: JOFFRE SECHIER E -Mail Address: Joffre @comfortmech.com Contractor Registration Number: COMFOMI015LA KENT City WA State Day Telephone: (425) 251 -9840 Fax Number: (425) 251 -9871 98032 Zip Expiration Date: 06/01/2012 ARCHITECT OF RECORD - All plans must be stamped by Architect of Record Company Name: Mailing Address: State Contact Person: E -Mail Address: City Day Telephone: Fax Number: Zip ENGINEER OF RECORD — All plans must be stamped by Engineer of Record Company Name: Mailing Address: Contact Person: E -Mail Address: City Day Telephone: Fax Number: State Zip H:Applications \Forms - Applications On Line\2010 Applications \7 -2010 - Plumbing -Gas Piping Permit Application.doc Revised: 7 -2010 bh Page 1 of 2 Valuation of Project (contractor's bid pri1 $ 1,250 10 Scope of Work (please provide detailed information): INSTALL 1 -1/2" GALVANIZED GAS PIPE TO NEW ROOFTOP UNIT. Building Use (per Int'l Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: Sewer: Indicate type of plumbing fixtures and /or gas piping outlets being installed and the quantity below: Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) Food -waste grinder, commercial Floor Drain Shower, single head trap Lavatory Wash fountain Receptor, indirect waste Sinks Urinals Water Closet Building sewer and each trailer park sewer Rain water system — per drain (inside building) Water heater and/or vent Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity) Grease interceptor for commercial kitchen ( >750 gallon capacity) Repair or alteration of water piping and/or water treatment equipment Repair or alteration of drainage or vent piping Medical gas piping system serving 1 -5 inlets/outlets for a specific gas Each additional medical gas inlets/outlets greater than 5 Backflow protective device other than atmospheric -type vacuum breakers 2 inch (51 mm) diameter or smaller Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Each lawn sprinkler system on any one meter including backflow protection devices Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1 -5) Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Gas piping outlets 1.8 PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PE Y BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNE 0 A fT / ZED_ AGENT: Signature: Print Name: JOFFRE SECHIER Date: 7" / /10 Day Telephone: 425 - 251 -9840 Mailing Address: 6802 S. 220TH ST. KENT WA 98032 City State Zip IDate Application Accepted: � l (,` 0 Date Application Expires: I Staff Initials: H:\Applications \Forms - Applications On lrne12010 Applications \7 -2010 - Plumbing -Gas Piping Permit Appltcanon.doc Revised: 7.2010 bh Page 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 0223100038 Address: 151 ANDOVER PK E TUKW Suite No: Applicant: US BANK RECEIPT Permit Number: PG 10 -086 Status: APPROVED Applied Date: 07/21/2010 Issue Date: Receipt No.: R10 -01501 Initials: User ID: Payee: WER 1655 Payment Amount: $63.00 Payment Date: 08/04/2010 02:4S PM Balance: $0.00 DON ULREY TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 614093 ACCOUNT ITEM LIST: Description 63.00 Account Code Current Pmts GAS - NONRES 000.322.103.00.00 63.00 Total: $63.00 PAYMENT RECEIVED doc: Receiot -06 Printed: 08 -04 -2010 -4( INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 P6 r o -04 Project: � �� �� Type � spectio0: � �� ks �2 ./ Address: 15 ( Am.d o v�.r- e, Date Called , —�" i Special Instructions:. / f/ Date Wanted: a.m. /0 — (Z—Pe0 Requester: Phone N o' / _3 0 �iilV -q�0 (p Approved per applicable codes. Corrections required. prior•to approval. COMMENTS: ,AA; h(e P r Inspector: Date: n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 6 PERT � : -., _ y411 PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: PG10 -086 PROJECT NAME: US BANK SITE ADDRESS: 151 ANDOVER PK E X Original Plan Submittal Response to Correction Letter # DATE: 07 -21 -10 Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: c 1-10 Building ivision Public Works Fire Prevention Structural Planning Division n Permit Coordinator 0 DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 07 -22 -10 Complete Comments: Incomplete Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES /THURS ROUTING: Please Route Structural Review Required No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 08 -19 -10 Approved Approved with Conditions Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 Contractors or Tradespeople Peter Friendly Page General /Specialty Contractor A business registered as a construction contractor with LEHI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name COMFORT MECHANICAL INC UBI No. 601954041 Phone 4252519840 Status Active Address 6802 So. 220Th Street License No. COMFOMI015LA Suite /Apt. License Type Construction Contractor City Kent Effective Date 6/1/1999 State WA Expiration 6/1/2012 Date Zip 98032 Suspend Date County King Specialty 1 Heating /Vent /Air - Conditioning And Refrig (Hvac /R) Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status FIVESM'010JT FIVE STAR MECHANICAL Construction Contractor General Unused 4/30/19994/30/2012 Active COMFOP'064D2 COMFORT PLUS Construction Contractor Air Conditioning Air Heat,Ventilation,Evaporat 3/22/1994 3/21/2000 Archived FIVESSE941KU FIVE STAR ENERGY SOLUTIONS Construction Contractor General Unused 5/24/20065/24/2008 06/01/2005 Expired Business Owner Information Name Role Effective Date Expiration Date JACKSON, SHIRLEY A President 01/01/1980 Amount JACKSON, HERB J Vice President 01/01/1980 9849307 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 2 COLONIAL AM CAS Et SURETY OF MD LPM4041162 06/01/2002 Until Cancelled $6,000.00 05/15/2002 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 8 FEDERATED MUTUAL INS CO 9849307 06/01/2010 06/01/2011 $1,000,000.0005 /03/2010 7 FEDERATED MUTUAL INS CO 9849306 06/01/2006 06/01/2010 $1,000,000.0005 /01/2009 6 FEDERATED SERV /MUT INS CO 9849306 06/01/2005 06/01/2006 $1,000,000.0004 /25/2005 5 FEDERATED MUTUAL INS CO 9849306 06/01/2004 06/01/2005 $1,000,000.00 04/30/2004 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period https://fortress.wa.gov/lni/bbip/Print. aspx 08/04/2010 ki King County Assessor information for parcel number 0223100038 Taxpayer name. Mailing address U s BANK CORPORATE PROPS 2800 E LAKE ST LAKE0012 MINNEAPOLIS MN ; 65406 Addresses) at this parcel 151 ANDOVER PARK—E-98-1-8-8- ARK E 98188 Parcel number 0223100038 Tax Account number 022310003805. Levy code 2390 Jurisdiction TUKWILA _ Present ,use.: Bank Appraised value $920,200 Legal description ANDOVER INDUSTRIAL PARK # 2 LESS W 402.01 FT LESS N 235 FT ASSESSOR DATA yry � . r va su . `r vu e4 w% i •G ! Y aFa1l.n.ht jP.�.4 . SITE PLAN Map of 151 Andover Park E Tukwila, WA by MapQuest MAPQYE,ST... 1•' L t u, V3. 16kii al , 8j 63ni :mil, t5 ,. dbc I x; .1S . t,",,, .... 4,70. ......i i'c'►3'6ia':.is? 1 II -4ti ?may* ti ti' /nte ' Family Fun GM Page 2 of 2 OI ISO e0a 11r.• *ttt amaay. 'y5!! F0911 Blf.ok Strog°.!,•! C` ;Trtok't]l, t L,:Irich , �r� ti4 it wrn(. ..` v i 4, 4' I jp2ObTlAipliiiestinO,L, VICINITY MAP.. Map Data m 200P P VTEQ or TeleAtlas HVAC Equipment Schedule (New) # Brand Model Ton 20 Tdai CFM 8,000 OSA CFM 1600 Econo. 0- 100% SP 0.5 Cap. Cool 265,550 EER 11 Btuh -In 400,000 Btuh- Out_AFUE 324,000 81 Weight 3228# 1 Trane YFD241 20 8,000 1600 _ HVAC Equipment Schedule (Existing) # Brand 1 Model Ton 'Total CFM OSA CFM Econo. 0 -100% SP 0.5 _Cy. Cool 240,000 EER 8.3 Btuh -In Btuh-Out . AFUE Weight 3375# 1 Lennox CHP11 -2753 20 8,000 1600 _ EQUIPMENT SCHEDULE PROJECT DESCRIPTION: 1. REPLACE (1) EXISTING 20 -TON ROOFTOP HEAT PUMP UNIT WITH NEW 20 -TON ROOFTOP GAS PACKAGED AIR CONDITIONING UNIT WITH ECONOMIZER: 2. EXISTING AIR DISTRIBUTION BEING REUSED "NO WORK ". 3. PROVIDE AND INSTALL NEW 7 -DAY PROGRAMMABLE THERMOSTAT. GENERAL NOTES: 1. ECONOMIZER TO PROVIDE 100% OUTSIDE AIR WITH PARTIAL COOLING. 2. THERMOSTAT TO PROVIDE MINIMUM 5° DEADBAND. 3. INSTALL GFCI OUTLET WITHIN 25' OF UNIT. 4. ROUTE CONDENSATE TO SPLASH BLOCK. 5. PROVIDE COMMISIONING REPORT WITH OPERATIONS AND MAINTENANCE MANUALS. 6. VERIFY ALL DUCT DIMENSIONS PRIOR TO INSTALLATION. 7. ALL DUCT DIMENSIONS ARE CLEAR INSIDE DIMENSIONS. ROOF ACCESS O 1.5" GAS LINE TO METER 110' TO METER RTU -1 ROOF PLAN (NTS) SEPARATE PERMIT REQUIRED FOR: 17 echanical Electrical ❑ Plumbing ❑ Gas Piping City of Tukwila aUILp 0 DIVISION REVISIONS No u cwt a Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. changes shall be made to the scope of work without prior approval of T I 'I B 'Id' g D' ' Y Permit xo.vb 10"" II Plan review approval is subject to errors and omissions. /0; r vat of construction documents does not authorize violation of an, . dopted code or ordinance. Receipt o1 approved Fie .... s y and loons is acknowledged: By Date: City Of Tukwila BUILDING DIVISION rG(o.o81o. REVIEWED FOR CODE COMPLIANCE APPROVED JUL 2 3 2010 A- - U, L City of Tukwjla BUILDING DIVISION RECEIVED JUL 212010 PERMIT CENTER REVISIONS J W 75 D Cl" C7) W j Z ° < "I Q� ��H DATE: SCALE: DRAWN: CHECKED: 1 Voyager YCD Items: YCD_ -1 (This item is not 'In Job') 7/13/2009 8:21:20 AM Comfort Mechanical- WFB Tukwila ermust 0-W keitg CORNER WEIGHT INSTALLED OPTIONS NET WEIGHT DATA Accessory Accessory Economizer 80.0 Ib Motorized Outside Air Damper 240,000 Manual Outside air Damper 28,800 Oversized Motor 8.30 High Efficiency Motor 8:3 High Static Drive Total capacity (Stull) Thnr the Base Electrical. Total unit wefts UM Mounted Circuit Breaker C.O.P. Unit Mounted Disconnect Low Temperature Hosting Ratings Power Exhaust 95.0 Ib Hinged Doors 18,700 . . Zone Sensor 2.1 LPG Conversion Kit Stage 1 Powered Convenience Outlet Stage 2 Adapter Curb 850.0 Ib BASE UNIT WEIGHTS CORNER WEIGHTS ` CENTER OF GRAVITY SHIPPING NET Maximum usable horsepower 5.75 Voltage &Phase 200/230/460v -3ph RPM range wino lb 2203.0 Ib 701.0 Ib 575.0 Ib 421.0 lb 604.0 lb 57" 38" NOTE: ' 1. CORNER WEIGHTS ARE GIVEN FOR INFORMATION ONLY. . 2. TO ESTIMATE SHIPPING WEIGHT OF OPTION /ACCESSORIES ADO 5 LBS TO NET WEIGHT. 3. NET WEIGHT OF OPTIONAL ACCESSORIES SHOULD BE ADD TO UNIT WEIGHT WHEN ORDERING FACTORY INSTALLED ACCESSORIES, 4. WEIGHTS FOR OPTIONS NOT LISTED ARE < 5 LBS. 5. WEIGHT ARE OF BASE UNIT ONLY. FOR TOTAL WEIGHT, 10 DIGIT FACTORY INSTALLED OPTION (ECONOMIZER AND /OR OVERSIZED MOTOR OR FIOP /ACCESSORY WEIGHT MUST BE ADDED.. RIGGING AND CENTER OF GRAVITY TOPSS Dimension Drawing ALLW ELHTS AND DBENSDNS ARE APPROXIMATE. CERTFED PRNTS ARE AVAIABLE UPON REQUEST. WEIGHT DATA (NEW UNIT): BASE UNIT: #2203 ECONOMIZER: #80 POWER EXHAUST: #95 ADAPTER CURB: #850 TOTAL W /ACC: #3328 Page: 4 SPECIFICATIONS Modal Number CHP11.3 •ARI Standard 340 Ratings Coating Ratings Cooling Capacity (Btuh) 240,000 Total unit watts 28,800 EER (Btuh /Watts) 8.30 Integrated Part Load Value 8:3 High Temperature • Heating Ratings Total capacity (Stull) 240,E Total unit wefts 24,700 C.O.P. 2.8 Low Temperature Hosting Ratings Total capacity (Btuh) 134,000 Total unit watts 18,700 . . C.O.P. 2.1 Refrigerant (221 charge Stage 1 34 lbs. 0 oz. Stage 2 31 lbs. 0 oz. ' Indoor Coil Blower and Drive Selection Blower wheel'nominal diameter x width (in.) . 15 x 15 . Factory InebtlMd • • tDrIvee • Nominal motor horsepower 5 Maximum usable horsepower 5.75 Voltage &Phase 200/230/460v -3ph RPM range 790 .-- 965 0.1800 - 780).. Optional Factory Installed tDrives Nominal motor horsepower 7.1/2 . Maximum usable horsepower 8.63 Voltage & Phase 200/230/480v -3ph RPM range 900 - 1070 Indoor Coil Net face Brea (sq. h.) 23.5 Tube diameter tin.) & No. of rows 1/2 - 4 '--„ Fins per Inch 15 Outdoor Coll Net face area (aq. h.) 38.9 Tube diameter (in.) & No. of rows 112 - 4 Fine parr inch 15 Outdoor Coil Fans • Diameter (in.) & No, of blades 12) 26 - 6 Air volume (cfm) 12) 8800 Motor horsepower (2) 1 Motor watts (2) 1000 Condensate drain size rnpt (in,) 12) 1 -1/4 No. & size of finery On.) 111) 18 x 20 X 1 Net weight of besic unit fibs.) (1 Package) 2900 Optional .. Electric Heat Model No ECH11 -275 kw input range 30- 45-80-76-90 Optional Roof Mounting Frame - (Net weight) Standard RMF11 -276 (316 lbs.) Horizontal RMFH11 -275 (440 lbs.) . Optional Economizer & Controls -- (Net weight) REMD11M -275 (290 lbs.) Optional Gravity Exhaust Dampers - (Net weight) GED11.275 (30 lbs.) Optional ' .. Power Exhaust. Dampers Model Ho. - (Net weight) . • . PED11- 276 (150 lbs.) r- Exhaust Flint OP�tion,r Coiling FIrW.+m Air )Not weight) Diameter (tn.) & No. of blades 13) 18 - 5 Total air volume (cfm) 7050 Motor horsepower (3) 1/4 Watts input (total) 1100 and Supply • Diffusers . . Step -down RTD11.275 1403 lbs.) Flush FD11. 2751383 Ibs.1 Transition SRT11 -275 (80 lbs.) Optional Fresh Air Damper & Finer Size (in.) -- (Net weight) Kit - )Net weight) . . OAD11. 275 (115 lbs.) 1 - 28 x 31 x 1 88G13 (16 Ilea.) Optional Automatic OAC11 Damper Electrical characteristics 200 to 480 volt - 80 hertz - 3 phase 'Rated in accordance with P.RI Standard 340. Cooling Ratings - 95°F outdoor air temperature and 63°F db /87 °F wb entering Indoor coil sir, minimum extemd duct static pressure. High Temperature Homing Ratings - 47"F rib /43°F wb outdoor air tsmpareturs end 70°F db entering indoor call air. Low Temperature Hitting Ratings - 17 °F db /15°F wb outdoor alr temperature and 70 °F db entering Indoor colt air. /Using total sir volume end system Ostia pressure requirement/ determine from blower performance tablet rpm and motor output required. ttMotor pulley furnished with unit for field Installation, if required. WEIGHT DATA (EXISTING UNIT): BASE UNIT: #2900 ELECTRIC HEAT: #155 ECONOMIZER: #290 EXHAUST DAMPER: #30 TOTAL W /ACC:. #3375 - 311 - ELECTRICAL DATA Model No. _ CHP11.2753. Line voltage data -. 60 Hz -. 3 phase 200V 230V 460V Compressor. (2) Rated load amps (total) 39.5/39.5 (79.0) 39.5/39.5 (79.0) 20.4/20.4 140.81 Locked rotor amps (total) 229/229 (488,0) 229/229 (468.0) . 116/118 (2321) Outdoor Coil Fen Motors (2). Full load amps (total) . . 12.8 10.4 . ._ 5.8 Locked rotor amps (total) _ 30 28 13.2. Indoor Coil Blower Motor . Horsepower, .. 5 7-1/2 • : 5. 7 -1/2 6 7 -1/2 Full load amps 17.6 26.3 15.2 22.0 . .., 7.6 11 ,. Locked rotor amps (No.) Horsepower 100.0 13) - 160.0. 1/4 . 90.0 (3) - 127.0 1/4 . . 45.0 . . . (3) - 64.0. 1/4 Optional Exhaust Fan Motors Full load amps (total) 4.2 4.2 . 2.2 Locked rotor amps (total) 9 8 91 4.9. Recom. max. fuse size lamps) Less Exhaust Fans 150 150 150 150 . 70 70 With Exhaust Fans 150 150. 160 150. 70 . .70 Unit Power Factor Less Exhaust Fans .88. .87 .88 .87 .. .88 .87 Wfth Exhaust Fans .88 17: .88 .87 .88 . .87 •Minimum Circuit Ampacity Less Exhaust Fans 120.0 127.0 115.0 122.0. ..60.0 83.0 . With Exhaust Fans 124.0. 132.0 119.0 128.0 62.0 65.0 'titter to National Electrical Coda manual to determine wire, fuse and disconnect size requirements. NOTE - Extreme of operating range are plus and minus 109E of line voltage. • OPTIONAL ELECTRIC HEAT DATA Electric Heat Model No. & Net Weight No. of Steps • Volts Input kw Input Stull Output ' Total Unit & Electric Heat ,Minimum Circuit Ameacity 5 hp 7.1/2 hp 200 20.8 71,000 201.0 209.0 23.0 78,500 210 . 2 220 25.2 85,000 tECH11 . 275 -30 230. 27.5 93,900 209.0 215.0 (135 lbs.) 240 30.0 102,400 440. 25.2 86,000 1 460 27.5 93,900 105.0 108.0 480 30.0 102,400 200 31.3 1.06,800 238.0 248.0 210. 34.5 117,700 3 220 37.8 129,000 tECH l 1- 275-45 230 41.3 141,000 262.0 259.0 (146 lbs.) 240 46.0 153,800 440 37.8 129,000 2 460 41.3 141,000 126.0 130.0 480 45.0 153,800 200 41.7 142,300 277.0 2851 210 48.0 157,000 4 220 50.4 172,000 tECH11. 275-65 230 55.1 188,100 297.0 304.0 (14: lbs.) . . 240 60.0 204,800 . 440 50.4 172,000 2 460 55.1 188,100 148.0 151.0 490 60.0 204,800 .. 200 52.1 177,700 318.0 328.0 210 57.4 196,000 6 220 83.0 215,000 - tECH11. 275 -75 230 68.9 235,000 342.0 349.0 (155 lbs.) 240 75.0. 255,900 440 63.0 216,000 3 460. 68.9 235,000 189.0 173.0 480 • 75.0 255,900 1EC1111- 275 -90 200 62.5 213,300 357.0 3864 210 68.9 235,000 (156 lbs.) "Refer to National Electrical Code menuel to determine coke, fuse end disconnect size requirements. Use wires euheble for at least 157 °F. 1 May be used with two stage control -31p- PG( 09 REVIEWED FOR . CODE COMPLIANCE. APPPflVED JUL .2 3 MO City of Tukwila BUILDING nn /ISIOM RECEIVED JUL 212010 PERMIT CENTER REVISIONS J V Ico iq ft(421E: 44L'4.--- O O c..3. woo > co 737-0. D c)- F-- < rn z 0 4CC°' mQ�. (/) D V"' H DATEr SCALE c DRAWN' CHECKED M2