HomeMy WebLinkAboutPermit PG10-086 - US BANKUS BANK
151 ANDOVER PK E
PG1 0-086
Parcel No.:
Address:
City oikukwila
•
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Inspection Request Line: 206 - 431 -2451
Web site: http. //www.ci.tukwila.wa.us
PLUMBING /GAS PIPING PERMIT
0223100038
151 ANDOVER PK E TUKW
Project Name: US BANK
Permit Number:
Issue Date:
Permit Expires On:
PG 10 -086
08/04/2010
01/31/2011
Owner:
Name:
Address:
Contact Person:
Name:
Address:
Email:
Contractor:
Name:
Address:
Contractor
U S BANK CORPORATE PROPS
2800 E LAKE ST , LAKE0012 55406
JOFFRE SECHIER
6802 S 220 ST , KENT WA 98032
JOFFRE @C OMFORTMECH. C OM
COMFORT MECHANICAL INC
6617 S 193 PL, #P -105 , KENT, WA 98032
License No: COMFOMI015LA
Phone: 425 - 251 -9840
Phone: 425 - 251 -9840
Expiration Date: 06/01/2012
DESCRIPTION OF WORK:
REISSUE OF EXPIRED PERMIT PG09 -134: INSTALL 1 1/2" GALVANIZED PIPE TO NEW
ROOFTOP UNIT
Value of Plumbing /Gas Piping:
Fees Collected:
Permit Center Authorized Signature:
$1,250.00
$63.00
Uniform Plumbing Code Edition: 2009
International Fuel Gas Code Edition: 2009
Date: V- 1
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be - = mplied with, whether specified herein or not.
The granting of this p mit • •es not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
ance of yvorJa. Jam authorized to sign and obtain this plumbing /gas piping permit
construction or the p
Signature:
Print Name:
Date:
This permit shall become null and void"if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
doc: UPC -4/10
PG10 -086
Printed: 08 -04 -2010
•
�J,�,�►a wqs City of Tukwila
Parcel No.:
Address:
Suite No:
Tenant:
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
0223100038
151 ANDOVER PK E TUKW
US BANK
PERMIT CONDITIONS
Permit Number:
Status:
Applied Date:
Issue Date:
PG 10 -086
ISSUED
07/21/2010
08/04/2010
1: ** *PLUMBING AND GAS PIPING * **
2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila
Building Division.
3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing
inspector.
4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas
Code.
5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved.
6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code.
Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to
make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection.
7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless,
adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the
conditioned space shall be insulated to minimum R -3.
8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be
protected by steel nail plates not less than 18 guage.
9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing
piping shall be directly embedded in concrete or masonry.
10: All pipes penetrating floor /ceiling assemblies and fire - resistance rated walls or partitions shall be protected in
accordance with the requirements of the building code.
11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to
twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill,
frozen earth, or construction debris.
12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an
approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the
jurisdiction.
* *continued on next page **
doc: Cond -10/06
PG 10 -086 Printed: 08 -04 -2010
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing
this work will be complied with, whether specified herein or not.
The granting of this per - does not presume to give authority to violate or cancel the provision of any other work or local laws regulating
construction or the p= o ance of work.
Signature:
Print Name:
Date: ,g //1
doc: Cond -10/06
PG10 -086 Printed: 08 -04 -2010
CITY OF TUKWILA
Community Development Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
htto://www.cLtukwila.wa.us
Plumbing /Gas Permit No. 1)6 0— 0 U f
ProjectNo.
(For office use only)
PLUMBING / GAS PIPING PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
SITE LOCATION
King Co Assessor's Tax No.: 0223100038
Site Address: 151 ANDOVER PK ili�6
Tenant Name: US BANK
Property Owners Name: US BANK CORPORATE PROPERTIES
Mailing Address: 2800 EAST LAKE ST.
Suite Number: Floor:
New Tenant: ❑ Yes ..No
City
State
Zip
CONTACT PERSON - Who do we contact when your permit is ready to be issued
Name: JOFFRE SECHIER
Mailing Address: 6802 S. 220TH ST.
E -Mail Address: joffre@comfortmech.com
Day Telephone:
KENT
(425) 251 -9840
WA
City State
Fax Number: (425) 251 -9871
98032
Zip
PLUMBING' / GAS PIPING' CONTRACTOR INFORMATION
Company Name: COMFORT MECHANICAL
Mailing Address: 6802 S. 220TH ST
Contact Person: JOFFRE SECHIER
E -Mail Address: Joffre @comfortmech.com
Contractor Registration Number: COMFOMI015LA
KENT
City
WA
State
Day Telephone: (425) 251 -9840
Fax Number: (425) 251 -9871
98032
Zip
Expiration Date: 06/01/2012
ARCHITECT OF RECORD - All plans must be stamped by Architect of Record
Company Name:
Mailing Address:
State
Contact Person:
E -Mail Address:
City
Day Telephone:
Fax Number:
Zip
ENGINEER OF RECORD — All plans must be stamped by Engineer of Record
Company Name:
Mailing Address:
Contact Person:
E -Mail Address:
City
Day Telephone:
Fax Number:
State
Zip
H:Applications \Forms - Applications On Line\2010 Applications \7 -2010 - Plumbing -Gas Piping Permit Application.doc
Revised: 7 -2010
bh
Page 1 of 2
Valuation of Project (contractor's bid pri1 $ 1,250 10
Scope of Work (please provide detailed information):
INSTALL 1 -1/2" GALVANIZED GAS PIPE TO NEW ROOFTOP UNIT.
Building Use (per Int'l Building Code):
Occupancy (per Int'l Building Code):
Utility Purveyor: Water: Sewer:
Indicate type of plumbing fixtures and /or gas piping outlets being installed and the quantity below:
Fixture Type:
Qty
Fixture Type:
Qty
Fixture Type:
Qty
Fixture Type:
Qty
Bathtub or combination
bath/shower
Bidet
Clothes washer, domestic
Dental unit, cuspidor
Dishwasher, domestic,
with independent drain
Drinking fountain or
water cooler (per head)
Food -waste grinder,
commercial
Floor Drain
Shower, single head trap
Lavatory
Wash fountain
Receptor, indirect waste
Sinks
Urinals
Water Closet
Building sewer and each
trailer park sewer
Rain water system — per
drain (inside building)
Water heater and/or vent
Industrial waste treatment
interceptor, including trap
and vent, except for kitchen
type grease interceptors
Each grease trap
(connected to not more
than 4 fixtures - <750
gallon capacity)
Grease interceptor for
commercial kitchen ( >750
gallon capacity)
Repair or alteration of
water piping and/or water
treatment equipment
Repair or alteration of
drainage or vent piping
Medical gas piping
system serving 1 -5
inlets/outlets for a
specific gas
Each additional medical
gas inlets/outlets greater
than 5
Backflow protective
device other than
atmospheric -type vacuum
breakers 2 inch (51 mm)
diameter or smaller
Backflow protective device
other than atmospheric -type
vacuum breakers over 2
inch (51 mm) diameter
Each lawn sprinkler
system on any one meter
including backflow
protection devices
Atmospheric -type vacuum
breakers not included in
lawn sprinkler backflow
protections (1 -5)
Atmospheric -type
vacuum breakers not
included in lawn
sprinkler backflow
protections over 5
Gas piping outlets
1.8
PERMIT APPLICATION NOTES -
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing
and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PE Y BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNE 0 A fT / ZED_ AGENT:
Signature:
Print Name:
JOFFRE SECHIER
Date: 7" / /10
Day Telephone: 425 - 251 -9840
Mailing Address: 6802 S. 220TH ST. KENT WA 98032
City
State
Zip
IDate Application Accepted: � l (,` 0
Date Application Expires: I
Staff Initials:
H:\Applications \Forms - Applications On lrne12010 Applications \7 -2010 - Plumbing -Gas Piping Permit Appltcanon.doc
Revised: 7.2010
bh
Page 2 of 2
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
Parcel No.: 0223100038
Address: 151 ANDOVER PK E TUKW
Suite No:
Applicant: US BANK
RECEIPT
Permit Number: PG 10 -086
Status: APPROVED
Applied Date: 07/21/2010
Issue Date:
Receipt No.: R10 -01501
Initials:
User ID:
Payee:
WER
1655
Payment Amount: $63.00
Payment Date: 08/04/2010 02:4S PM
Balance: $0.00
DON ULREY
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Credit Crd VISA
Authorization No. 614093
ACCOUNT ITEM LIST:
Description
63.00
Account Code Current Pmts
GAS - NONRES
000.322.103.00.00 63.00
Total: $63.00
PAYMENT
RECEIVED
doc: Receiot -06 Printed: 08 -04 -2010
-4(
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670
Permit Inspection Request Line (206) 431 -2451
P6 r o -04
Project: � ��
��
Type � spectio0: �
�� ks �2 ./
Address:
15 ( Am.d o v�.r- e,
Date Called
, —�" i
Special Instructions:.
/
f/
Date Wanted: a.m.
/0 — (Z—Pe0
Requester:
Phone N o' / _3 0
�iilV -q�0 (p
Approved per applicable codes. Corrections required. prior•to approval.
COMMENTS:
,AA; h(e P
r
Inspector:
Date:
n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
6
PERT � : -., _ y411
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: PG10 -086
PROJECT NAME: US BANK
SITE ADDRESS: 151 ANDOVER PK E
X Original Plan Submittal
Response to Correction Letter #
DATE: 07 -21 -10
Response to Incomplete Letter #
Revision # After Permit Issued
DEPARTMENTS:
c 1-10
Building ivision
Public Works
Fire Prevention
Structural
Planning Division
n Permit Coordinator
0
DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 07 -22 -10
Complete
Comments:
Incomplete
Not Applicable
Permit Center Use Only
INCOMPLETE LETTER MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
LETTER OF COMPLETENESS MAILED:
TUES /THURS ROUTING:
Please Route
Structural Review Required
No further Review Required
n
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS:
DUE DATE: 08 -19 -10
Approved Approved with Conditions Not Approved (attach comments)
Notation:
REVIEWER'S INITIALS: DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections:
Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents /routing slip.doc
2 -28 -02
Contractors or Tradespeople Peter Friendly Page
General /Specialty Contractor
A business registered as a construction contractor with LEHI to perform construction work within the scope of
its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Business and Licensing Information
Name COMFORT MECHANICAL
INC
UBI No. 601954041
Phone 4252519840 Status Active
Address 6802 So. 220Th Street License No. COMFOMI015LA
Suite /Apt. License Type Construction Contractor
City Kent Effective Date 6/1/1999
State WA Expiration 6/1/2012
Date
Zip 98032 Suspend Date
County King Specialty 1 Heating /Vent /Air - Conditioning And Refrig
(Hvac /R)
Business Type Corporation Specialty 2 Unused
Parent
Company
Other Associated Licenses
License
Name
Type
Specialty 1
Specialty 2
Effective
Date
Expiration
Date
Status
FIVESM'010JT
FIVE STAR
MECHANICAL
Construction
Contractor
General
Unused
4/30/19994/30/2012
Active
COMFOP'064D2
COMFORT
PLUS
Construction
Contractor
Air
Conditioning
Air
Heat,Ventilation,Evaporat
3/22/1994
3/21/2000
Archived
FIVESSE941KU
FIVE STAR
ENERGY
SOLUTIONS
Construction
Contractor
General
Unused
5/24/20065/24/2008
06/01/2005
Expired
Business Owner Information
Name
Role
Effective Date
Expiration Date
JACKSON, SHIRLEY A
President
01/01/1980
Amount
JACKSON, HERB J
Vice President
01/01/1980
9849307
Bond Information
Page 1 of 2
Bond
Bond Company Name
Bond Account Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Bond Amount
Received Date
2
COLONIAL AM CAS Et
SURETY OF MD
LPM4041162
06/01/2002
Until Cancelled
$6,000.00
05/15/2002
Assignment of Savings Information No records found for the previous 6 year period
Insurance Information
Insurance
Company Name
Policy Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Amount
Received Date
8
FEDERATED
MUTUAL INS CO
9849307
06/01/2010
06/01/2011
$1,000,000.0005
/03/2010
7
FEDERATED
MUTUAL INS CO
9849306
06/01/2006
06/01/2010
$1,000,000.0005
/01/2009
6
FEDERATED
SERV /MUT INS
CO
9849306
06/01/2005
06/01/2006
$1,000,000.0004
/25/2005
5
FEDERATED
MUTUAL INS CO
9849306
06/01/2004
06/01/2005
$1,000,000.00
04/30/2004
Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period
https://fortress.wa.gov/lni/bbip/Print. aspx
08/04/2010
ki King County
Assessor information for parcel number 0223100038
Taxpayer name.
Mailing address
U s BANK CORPORATE PROPS
2800 E LAKE ST
LAKE0012
MINNEAPOLIS MN ; 65406
Addresses) at this parcel 151 ANDOVER PARK—E-98-1-8-8-
ARK E 98188
Parcel number 0223100038
Tax Account number 022310003805.
Levy code 2390
Jurisdiction TUKWILA
_
Present ,use.: Bank
Appraised value $920,200
Legal description
ANDOVER INDUSTRIAL PARK # 2 LESS W 402.01 FT LESS N 235 FT
ASSESSOR DATA
yry � . r va su . `r vu
e4 w% i •G ! Y aFa1l.n.ht jP.�.4 .
SITE PLAN
Map of 151 Andover Park E Tukwila, WA by MapQuest
MAPQYE,ST...
1•' L
t u,
V3. 16kii al ,
8j 63ni
:mil, t5 ,.
dbc I x;
.1S . t,",,, .... 4,70. ......i
i'c'►3'6ia':.is? 1 II
-4ti ?may*
ti ti' /nte '
Family Fun GM
Page 2 of 2
OI
ISO
e0a 11r.•
*ttt amaay.
'y5!!
F0911 Blf.ok
Strog°.!,•!
C`
;Trtok't]l, t L,:Irich ,
�r� ti4
it
wrn(.
..` v i 4,
4' I
jp2ObTlAipliiiestinO,L,
VICINITY MAP..
Map Data m 200P P VTEQ or TeleAtlas
HVAC Equipment Schedule (New)
#
Brand
Model
Ton
20
Tdai CFM
8,000
OSA CFM
1600
Econo.
0- 100%
SP
0.5
Cap. Cool
265,550
EER
11
Btuh -In
400,000
Btuh- Out_AFUE
324,000
81
Weight
3228#
1
Trane
YFD241
20
8,000
1600 _
HVAC Equipment Schedule (Existing)
#
Brand
1 Model
Ton
'Total CFM
OSA CFM
Econo.
0 -100%
SP
0.5
_Cy. Cool
240,000
EER
8.3
Btuh -In
Btuh-Out
. AFUE
Weight
3375#
1
Lennox
CHP11 -2753
20
8,000
1600 _
EQUIPMENT SCHEDULE
PROJECT DESCRIPTION:
1. REPLACE (1) EXISTING 20 -TON ROOFTOP HEAT PUMP UNIT WITH NEW
20 -TON ROOFTOP GAS PACKAGED AIR CONDITIONING UNIT WITH
ECONOMIZER:
2. EXISTING AIR DISTRIBUTION BEING REUSED "NO WORK ".
3. PROVIDE AND INSTALL NEW 7 -DAY PROGRAMMABLE THERMOSTAT.
GENERAL NOTES:
1. ECONOMIZER TO PROVIDE 100% OUTSIDE AIR WITH PARTIAL COOLING.
2. THERMOSTAT TO PROVIDE MINIMUM 5° DEADBAND.
3. INSTALL GFCI OUTLET WITHIN 25' OF UNIT.
4. ROUTE CONDENSATE TO SPLASH BLOCK.
5. PROVIDE COMMISIONING REPORT WITH OPERATIONS AND
MAINTENANCE MANUALS.
6. VERIFY ALL DUCT DIMENSIONS PRIOR TO INSTALLATION.
7. ALL DUCT DIMENSIONS ARE CLEAR INSIDE DIMENSIONS.
ROOF ACCESS
O
1.5" GAS LINE TO METER
110' TO METER
RTU -1
ROOF PLAN (NTS)
SEPARATE PERMIT
REQUIRED FOR:
17 echanical
Electrical
❑ Plumbing
❑ Gas Piping
City of Tukwila
aUILp 0 DIVISION
REVISIONS
No
u cwt a Building Division.
NOTE: Revisions will require a new plan submittal
and may include additional plan review fees.
changes shall be made to the scope
of work without prior approval of
T I 'I B 'Id' g D'
' Y
Permit
xo.vb 10"" II
Plan review approval is subject to errors and omissions.
/0; r vat of construction documents does not authorize
violation of an, . dopted code or ordinance. Receipt
o1 approved Fie .... s y and loons is acknowledged:
By
Date:
City Of Tukwila
BUILDING DIVISION
rG(o.o81o.
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JUL 2 3 2010
A- - U, L
City of Tukwjla
BUILDING DIVISION
RECEIVED
JUL 212010
PERMIT CENTER
REVISIONS
J
W
75
D Cl" C7)
W j
Z °
< "I
Q�
��H
DATE:
SCALE:
DRAWN:
CHECKED:
1
Voyager YCD
Items: YCD_ -1
(This item is not 'In Job')
7/13/2009 8:21:20 AM
Comfort Mechanical- WFB Tukwila
ermust
0-W
keitg
CORNER WEIGHT
INSTALLED OPTIONS NET WEIGHT DATA
Accessory
Accessory
Economizer
80.0 Ib
Motorized Outside Air Damper
240,000
Manual Outside air Damper
28,800
Oversized Motor
8.30
High Efficiency Motor
8:3
High Static Drive
Total capacity (Stull)
Thnr the Base Electrical.
Total unit wefts
UM Mounted Circuit Breaker
C.O.P.
Unit Mounted Disconnect
Low Temperature
Hosting Ratings
Power Exhaust
95.0 Ib
Hinged Doors
18,700 . .
Zone Sensor
2.1
LPG Conversion Kit
Stage 1
Powered Convenience Outlet
Stage 2
Adapter Curb
850.0 Ib
BASE UNIT WEIGHTS
CORNER WEIGHTS `
CENTER OF GRAVITY
SHIPPING
NET
Maximum usable horsepower
5.75
Voltage &Phase
200/230/460v -3ph
RPM range
wino lb
2203.0 Ib
701.0 Ib
575.0 Ib
421.0 lb
604.0 lb
57"
38"
NOTE: '
1. CORNER WEIGHTS ARE GIVEN FOR INFORMATION ONLY. .
2. TO ESTIMATE SHIPPING WEIGHT OF OPTION /ACCESSORIES ADO 5 LBS TO NET WEIGHT.
3. NET WEIGHT OF OPTIONAL ACCESSORIES SHOULD BE ADD TO UNIT WEIGHT WHEN
ORDERING FACTORY INSTALLED ACCESSORIES,
4. WEIGHTS FOR OPTIONS NOT LISTED ARE < 5 LBS.
5. WEIGHT ARE OF BASE UNIT ONLY. FOR TOTAL WEIGHT, 10 DIGIT FACTORY INSTALLED
OPTION (ECONOMIZER AND /OR OVERSIZED MOTOR OR FIOP /ACCESSORY WEIGHT
MUST BE ADDED..
RIGGING AND CENTER OF GRAVITY
TOPSS Dimension Drawing
ALLW ELHTS AND DBENSDNS ARE APPROXIMATE. CERTFED PRNTS ARE AVAIABLE UPON REQUEST.
WEIGHT DATA (NEW UNIT):
BASE UNIT: #2203
ECONOMIZER: #80
POWER EXHAUST: #95
ADAPTER CURB: #850
TOTAL W /ACC: #3328
Page: 4
SPECIFICATIONS
Modal Number
CHP11.3
•ARI
Standard 340
Ratings
Coating
Ratings
Cooling Capacity (Btuh)
240,000
Total unit watts
28,800
EER (Btuh /Watts)
8.30
Integrated Part Load Value
8:3
High Temperature
•
Heating Ratings
Total capacity (Stull)
240,E
Total unit wefts
24,700
C.O.P.
2.8
Low Temperature
Hosting Ratings
Total capacity (Btuh)
134,000
Total unit watts
18,700 . .
C.O.P.
2.1
Refrigerant (221 charge
Stage 1
34 lbs. 0 oz.
Stage 2
31 lbs. 0 oz.
' Indoor
Coil
Blower
and
Drive
Selection
Blower wheel'nominal diameter x width (in.) .
15 x 15 .
Factory
InebtlMd
•
• tDrIvee
•
Nominal motor horsepower
5
Maximum usable horsepower
5.75
Voltage &Phase
200/230/460v -3ph
RPM range
790 .-- 965 0.1800 - 780)..
Optional
Factory
Installed
tDrives
Nominal motor horsepower
7.1/2 .
Maximum usable horsepower
8.63
Voltage & Phase
200/230/480v -3ph
RPM range
900 - 1070
Indoor
Coil
Net face Brea (sq. h.)
23.5
Tube diameter tin.) & No. of rows
1/2 - 4
'--„
Fins per Inch
15
Outdoor
Coll
Net face area (aq. h.)
38.9
Tube diameter (in.) & No. of rows
112 - 4
Fine parr inch
15
Outdoor Coil
Fans •
Diameter (in.) & No, of blades
12) 26 - 6
Air volume (cfm)
12) 8800
Motor horsepower
(2) 1
Motor watts
(2) 1000
Condensate drain size rnpt (in,)
12) 1 -1/4
No. & size of finery On.)
111) 18 x 20 X 1
Net weight of besic unit fibs.) (1 Package)
2900
Optional ..
Electric Heat
Model No
ECH11 -275
kw input range
30- 45-80-76-90
Optional Roof Mounting Frame - (Net weight)
Standard
RMF11 -276 (316 lbs.)
Horizontal
RMFH11 -275 (440 lbs.) .
Optional Economizer & Controls -- (Net weight)
REMD11M -275 (290 lbs.)
Optional Gravity Exhaust Dampers - (Net weight)
GED11.275 (30 lbs.)
Optional ' ..
Power
Exhaust.
Dampers
Model Ho. - (Net weight) . •
. PED11- 276 (150 lbs.)
r-
Exhaust
Flint
OP�tion,r Coiling
FIrW.+m Air
)Not weight)
Diameter (tn.) & No. of blades
13) 18 - 5
Total air volume (cfm)
7050
Motor horsepower
(3) 1/4
Watts input (total)
1100
and
Supply •
Diffusers
. .
Step -down
RTD11.275 1403 lbs.)
Flush
FD11. 2751383 Ibs.1
Transition
SRT11 -275 (80 lbs.)
Optional Fresh Air Damper &
Finer Size (in.) -- (Net weight)
Kit - )Net weight) .
. OAD11. 275 (115 lbs.) 1 - 28 x 31 x 1
88G13 (16 Ilea.)
Optional Automatic OAC11 Damper
Electrical characteristics
200 to 480 volt - 80 hertz - 3 phase
'Rated in accordance with P.RI Standard 340.
Cooling Ratings - 95°F outdoor air temperature and 63°F db /87 °F wb entering Indoor coil sir, minimum extemd duct static pressure.
High Temperature Homing Ratings - 47"F rib /43°F wb outdoor air tsmpareturs end 70°F db entering indoor call air.
Low Temperature Hitting Ratings - 17 °F db /15°F wb outdoor alr temperature and 70 °F db entering Indoor colt air.
/Using total sir volume end system Ostia pressure requirement/ determine from blower performance tablet rpm and motor output required.
ttMotor pulley furnished with unit for field Installation, if required.
WEIGHT DATA (EXISTING UNIT):
BASE UNIT: #2900
ELECTRIC HEAT: #155
ECONOMIZER: #290
EXHAUST DAMPER: #30
TOTAL W /ACC:. #3375
- 311 -
ELECTRICAL DATA
Model No. _
CHP11.2753.
Line voltage data -. 60 Hz -. 3 phase
200V
230V
460V
Compressor. (2)
Rated load amps (total)
39.5/39.5
(79.0)
39.5/39.5
(79.0)
20.4/20.4
140.81
Locked rotor amps (total)
229/229
(488,0)
229/229
(468.0)
. 116/118
(2321)
Outdoor Coil
Fen Motors (2).
Full load amps (total) . .
12.8
10.4 .
._ 5.8
Locked rotor amps (total) _
30
28
13.2.
Indoor Coil
Blower Motor .
Horsepower, ..
5
7-1/2
• : 5.
7 -1/2
6
7 -1/2
Full load amps
17.6
26.3
15.2
22.0 .
.., 7.6
11 ,.
Locked rotor amps
(No.) Horsepower
100.0
13) -
160.0.
1/4
. 90.0
(3) -
127.0
1/4 .
. 45.0
. . . (3) -
64.0.
1/4
Optional
Exhaust Fan
Motors
Full load amps (total)
4.2
4.2
. 2.2
Locked rotor amps (total)
9 8
91
4.9.
Recom. max.
fuse size lamps)
Less Exhaust Fans
150
150
150
150 .
70
70
With Exhaust Fans
150
150.
160
150.
70 .
.70
Unit
Power Factor
Less Exhaust Fans
.88.
.87
.88
.87 ..
.88
.87
Wfth Exhaust Fans
.88
17:
.88
.87
.88 .
.87
•Minimum
Circuit Ampacity
Less Exhaust Fans
120.0
127.0
115.0
122.0.
..60.0
83.0 .
With Exhaust Fans
124.0.
132.0
119.0
128.0
62.0
65.0
'titter to National Electrical Coda manual to determine wire, fuse and disconnect size requirements.
NOTE - Extreme of operating range are plus and minus 109E of line voltage. •
OPTIONAL ELECTRIC HEAT DATA
Electric Heat
Model No.
& Net Weight
No.
of
Steps
•
Volts
Input
kw
Input
Stull
Output
' Total Unit &
Electric Heat
,Minimum Circuit
Ameacity
5 hp
7.1/2 hp
200
20.8
71,000
201.0
209.0
23.0
78,500
210
.
2
220
25.2
85,000
tECH11 . 275 -30
230.
27.5
93,900
209.0
215.0
(135 lbs.)
240
30.0
102,400
440.
25.2
86,000
1
460
27.5
93,900
105.0
108.0
480
30.0
102,400
200
31.3
1.06,800
238.0
248.0
210.
34.5
117,700
3
220
37.8
129,000
tECH l 1- 275-45
230
41.3
141,000
262.0
259.0
(146 lbs.)
240
46.0
153,800
440
37.8
129,000
2
460
41.3
141,000
126.0
130.0
480
45.0
153,800
200
41.7
142,300
277.0
2851
210
48.0
157,000
4
220
50.4
172,000
tECH11. 275-65
230
55.1
188,100
297.0
304.0
(14: lbs.)
. .
240
60.0
204,800
.
440
50.4
172,000
2
460
55.1
188,100
148.0
151.0
490
60.0
204,800
..
200
52.1
177,700
318.0
328.0
210
57.4
196,000
6
220
83.0
215,000
-
tECH11. 275 -75
230
68.9
235,000
342.0
349.0
(155 lbs.)
240
75.0.
255,900
440
63.0
216,000
3
460.
68.9
235,000
189.0
173.0
480 •
75.0
255,900
1EC1111- 275 -90
200
62.5
213,300
357.0
3864
210
68.9
235,000
(156 lbs.)
"Refer to National Electrical Code menuel to determine coke, fuse end disconnect
size requirements. Use wires euheble for at least 157 °F.
1 May be used with two stage control
-31p-
PG(
09
REVIEWED FOR .
CODE COMPLIANCE.
APPPflVED
JUL .2 3 MO
City of Tukwila
BUILDING nn /ISIOM
RECEIVED
JUL 212010
PERMIT CENTER
REVISIONS
J
V
Ico iq
ft(421E: 44L'4.---
O
O
c..3.
woo
> co
737-0.
D c)-
F-- <
rn
z 0 4CC°'
mQ�.
(/)
D V"' H
DATEr
SCALE c
DRAWN'
CHECKED
M2