Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit PG10-097 - WESTFIELD SOUTHCENTER MALL - FRANCESCA'S COLLECTIONS
FRANCESCA'S COLLECTIONS 611 SOUTHCENTER MALL PG1O-097 City okukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 -431 -2451 Web site: http: / /www.ci.tukwila.wa.us PLUMBING /GAS PIPING PERMIT Parcel No.: 9202470010 Address: 611 SOUTHCENTER MALL TUKW Project Name: FRANCESCA'S COLLECTIONS Permit Number: PG 10 -097 Issue Date: 09/03/2010 Permit Expires On: 03/02/2011 Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA 92013 Contact Person: Name: KYLE KIMBERLAIN Address: 6939 MARINER DR #D , RACINE WI 53406 Email: KYLE @RETAILSTORECONSTRUCTION.COM Contractor: Name: RETAIL STORE CONSTRUCTION Address: 6939 MARINER DR , RACINE WI 53406 Contractor License No: RETAISC908LM Phone: 262- 886 -9800 Phone: 262 - 886 -9800 Expiration Date: 06/14/2012 DESCRIPTION OF WORK: INSTALL MOP SINK AND WATER HEATER Value of Plumbing /Gas Piping: $1,000.00 Uniform Plumbing Code Edition: 2009 Fees Collected: $171.94 International Fuel Gas Code Edition: 2009 Permit Center Authorized Signature: Date: q-3-- 0 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this p mit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the erformance of wor.. I am it. • rized to sign and obtain this plumbing /gas piping permit. Q z /I Signature: G�(/1/1A'" / Date: / / / -c \/144i/tA -e-7 This permit shall become null and void if the work is no commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: UPC -4/10 PG10 -097 Printed: 09 -03 -2010 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone : 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 9202470010 Address: Suite No: Tenant: 611 SOUTHCENTER MALL TUKW FRANCESCA'S COLLECTIONS PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: PG 10 -097 ISSUED 08/03/2010 09/03/2010 1: ** *PLUMBING AND GAS PIPING * ** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in art exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R -3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor /ceiling assemblies and fire - resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures and fittings in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use significant quantities of water shall comply with Washington States Water Efficiency and Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 402 of Washington State Amendments. 12: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 13: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. * *continued on next page ** doc: Cond -10/06 PG 10 -097 Printed: 09 -03 -2010 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Signature: Print Name: Date: f-? — 7 ordinances governing or local laws regulating doc: Cond -10/06 PG10 -097 Printed: 09 -03 -2010 Site Address: CITY OF TUKWILO Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto://www.ci.tukwila.wa.us 'lumbing /Gas Permit roject No �t For office use only) PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** (0 (l 6v6- 111eP..w4 -- Tenant Name: / a t e 5 C'a S JJ rr Property Owners Name: I t )/ gtAt°elei G,L Mailing Address: e- Ciict.7Ae -ej:c�- King Co Assessor's Tax No.: Suite Number: 57eR Floor: New Tenant: Yes ❑..No '2G #IQ City State rgvigg Zip :CONTACT PERSON -.Who do we contact when your permit: is ready to be issued Name: ,/ /e e�0�•.17r,-11P..G Mailing Address: 6�/3% (arrk.er' E -Mail Address: k �n.h°1( (On5t/e7+.01fia Day Telephone: :c'l1P City Fax Number: tJ - 53 Vet State Zip PLUM•BING;/ GAS PIPING: CONTRACTOR INFORMATI Company Name:�17 Mailing Address: State Zip Contact Person: E -Mail Address: Contractor Registration Number: City Day Telephone: Fax Number: Expiration Date: ARCHITECT OF RE,CORD - Ail plans must be wetstamped.by Architect of Record Company Name: Mailing Address: Contact Person: E -Mail Address: Age � r1 r` ea kS�/Q /Qh , / �otPet /AJJJ S--qC 1— 1901 e. l r kJ % State City /gyp Day Telephone: hC) — ?NS- - --a760 Fax Number: 60g _ 756 - a75-0 LENGINEER,:OF RECORD - All plans °must be wet stamped by. Engineer of Record Company Name: Mailing Address: �t4tklAa_tM et 1APP��n� !'IPnlnaa ®dal Contact Person: /rvc1 / t tit e 5 E -Mail Address: r -f O P0, es 43 (Av La wl Pitiq • Cd �`'1 H:\Applications\Porns- Applications On Line\2009 Applications \1-2009 - Plumbing -Gas Piping Permit Application.doc Revised: 1 -2009 bh City / State Day Telephone: t' I Fax Number: Page 1 of 2 w Valuation of Project (contractor's bid price): $ 7� &O() / 1 P / Scope of Work (please provide detailed information): J 6hx II vki-2 /f k / ( ejJ&I v Building Use (per Int'I Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: Sewer: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Fixture•Type: Qty . ;;Fixture Type: '' ' •. Qty : Fixture Type: ; '; Qty Fixture Type: Qty,:: Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) f Food -waste grinder, commercial Floor Drain Shower, single head trap Lavatory Wash fountain Receptor, indirect waste Sinks 9 t Urinals Water Closet Building sewer and each trailer park sewer Rain water system — per drain (inside building) Water heater and /or vent j I Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity) Grease interceptor for commercial kitchen ( >750 gallon capacity) Repair or alteration of water piping and /or water treatment equipment I Repair or alteration of drainage or vent piping I Medical gas piping system serving 1 -5 inlets /outlets for a specific gas Each additional medical gas inlets /outlets greater than 5 Backflow protective device other than atmospheric -type vacuum breakers 2 inch (51 mm) diameter or smaller Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter •Each lawn sprinkler system on any one meter including backflow protection devices Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1 -5) Atmospheric -type vacuum breakers not . included in lawn sprinkler backflow protections over 5 Gas piping outlets PERMIT 'APPLICATION.NOTES., Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. n ZED AGENT: 1 m i. BUILDING OWNER OR AU Signature: Print Name: K� I p Iccp IMl orL' vt. Mailing Address: 6439 I7(Ccv%u er t/r 4f J e tl "76,19 c Date: Day Telephone: 02607 - Pg% - ` State Zip City Date Application Accepted: i - # ( U Date Application Expires: �� t Staff Initials: 1 H:\Applications \Forms - Applications On Line \2009 Applications \I-2009 - Plumbing -Gas Piping Permit Application.doc Revised: 1 -2009 bh Page 2 of 2 • City of Tukwila t� \Z Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us RECEIPT Parcel No.: 9202470010 Permit Number: PG10 -097 Address: 611 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 08/03/2010 Applicant: FRANCESCA'S COLLECTIONS Issue Date: Receipt No.: R10 -01756 Payment Amount: $137.55 Initials: WER Payment Date: 09/03/2010 11:12 AM User ID: 1655 Balance: $0.00 Payee: RETAIL STORE CONSTRUCTION TRANSACTION LIST: Type Method Descriptio Amount Payment Check 4057 137.55 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts PLUMBING - NONRES 000.322.103.00.00 137.55 Total: $137.55 PAYMENT F(Fl\IEn doc: Receipt -06 Printed: 09 -03 -2010 • • J��f,LA wq City of Tukwila zDepartment of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 9202470010 Permit Number: PG 10 -097 Address: 611 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 08/03/2010 Applicant: FRANCESCA'S COLLECTION Issue Date: Receipt No.: R10 -01481 Payment Amount: $34.39 Initials: WER Payment Date: 08/03/2010 02:40 PM User ID: 1655 Balance: $137.55 Payee: RETAIL STORE CONSTRUCTION TRANSACTION LIST: Type Method Descriptio Amount Payment Check 3926 34.39 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 34.39 Total: $34.39 PAYMENT F(FVEP• doc: Receiot -06 Printed: 08 -03 -2010 INSPECTION RECORD Retain a copy with permit INSPECTIO NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Projec : ( H rr i\ (°S(4- ) Type10Inspection: r ` f �1 ,a-. A . r\ '47' Address: (0 t c S ( / Date Called: Special Instructions: Date Wanted: [ D ��� p a.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: eA,4\ r■er ()A. r-vJA...o 13 at sOw Ade Insp tor: n REINSPECTION FEE REQUIREb. Prior to next inspection, fee,must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: • PLAN &Val TING SLIP ACTIVITY NUMBER: PG10 -097 DATE: 08 -03 -10 PROJECT NAME: FRANCESCA'S COLLECTIONS SITE ADDRESS: 611 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS : 0$ ffing Division M N /11- P ublic Works Fire Prevention Structural Planning Division Permit Coordinator n 1 DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 08-05-10 Not Applicable a Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 09-02-10 Not Approved (attach comments) n DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 Contractors or Tradespeople Pf ter Friendly Page General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name RETAIL STORE CONSTRUCTION INC UBI No. 602773086 Phone 2628869800 Status Active Address 6939 Mariner Dr License No. RETAISC908LM Suite /Apt. License Type Construction Contractor City Racine Effective Date 6/14/2010 State WI Expiration Date 6/14/2012 Zip 53406 Suspend Date County Out Of State Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Business Owner Information Name Role Effective Date Expiration Date KIMBERLAIN, KYLE J President 06/14/2010 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 NORTH AMERICAN SPEC INS CO 2135100 06/03/2010 Until Cancelled $12,000.00 06/14/2010 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 1 WEST BEND MUTUAL CPW0728307 11/21/2009 11/21/2010 $1,000,000.00 06/14/2010 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https: // fortress .wa.gov /lni /bbip /Print.aspx 09/03/2010 ABBREVIATIONS FD=... FS FCO CO VTR BFP HB S5 GW FLOOR DRAIN FLOOR SINK FLOOR CLEAN -OUT CLEAN -OUT VENT THROUGH ROOF BACK FLOW PREVENTER HOSE BIBB SANITARY SEWER GREASE WASTE REVISIONS No changes shall be made to the scope of Work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. MECHANICAL SYMBOLS LEGEND SYMBOL LEGE \9 i— ELBOW DOWN 3 .I-JN-- EXHAUST AIR WALL CLEANOUT --U SIZE PIPE CAP igi T �-,I FLEXIBLE DUCT ELBOW UP O EXISTING UP TT O TEE, OUTLET 1 B Jr TEE, OUTLET DOWN N CHECK VALVE EXISTING IMCI. 24" X 24" 1 D4 SHUTOFF VALVE BRING TO 'LIKE -NEW' PRESSURE REDUCING VALVE (SETTING AS NOTED, PSI) 0 RETURN DUCT UP, NEGATIVE PRESSURE Ibl BALL VALVE —1r� VALVE -- BUTTERFLY EXHAUST DUCT UP, NEGATIVE PRESSURE REDUCED PRESSURE ZONE BACKFLOW PREVENTER SOLENOID VALVE /I/ SUPPLY DUCT DOWN, POSITIVE PRESSURE D�4 GAS PRESSURE REGULATOR VALVE PIPE UNION �►� SHOCK ABSORBER S FLEXIBLE DUCTWORK CONNECTION TO UNIT III 1 ELBOW FLOOR DRAIN p, SUPPLY DIFFUSER /REGISTER BLANKOFF INDICATED SHADED FLOOR SINK e WH 1 !I WALL HYDRANT HB +I-- HOSE BIBB FLOOR CLEANOUT - - -1$1 • GAS COCK VALVE kgX -10 TYPE - NECK SIZE ABBREVIATIONS FD=... FS FCO CO VTR BFP HB S5 GW FLOOR DRAIN FLOOR SINK FLOOR CLEAN -OUT CLEAN -OUT VENT THROUGH ROOF BACK FLOW PREVENTER HOSE BIBB SANITARY SEWER GREASE WASTE REVISIONS No changes shall be made to the scope of Work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. MECHANICAL SYMBOLS LEGEND SUPPLY AIR i— 4-w- RETURN AIR FINISH .I-JN-- EXHAUST AIR 4:;53 S-71---4 STANDARD BRANCH, NO SPLITTER - SUPPLY FLOW TO RIGHT - RETURN /EXHAUST FLOW TO LEFT 6/29/10 SIZE S BELLMOUTH WITH BALANCING DAMPER ' igi T �-,I FLEXIBLE DUCT SUPPLY WHITE EXISTING EXISTING X TURNING VANES 1 B Jr r + MANUAL VOLUME DAMPER WHITE EXISTING EXISTING IMCI. 24" X 24" 1 SUPPLY DUCT UP, POSITIVE PRESSURE s— BRING TO 'LIKE -NEW' 1. EXISTING CONDITION 0 RETURN DUCT UP, NEGATIVE PRESSURE S— N +N EXHAUST DUCT UP, NEGATIVE PRESSURE S /11 S /I/ SUPPLY DUCT DOWN, POSITIVE PRESSURE �01 f--® RETURN DUCT DOWN, NEGATIVE PRESSURE �►� S—® EXHAUST DUCT DOWN, NEGATIVE PRESSURE S FLEXIBLE DUCTWORK CONNECTION TO UNIT III p, SUPPLY DIFFUSER /REGISTER BLANKOFF INDICATED SHADED 1 TYPE - NECK SIZE 375 SUPPLY DIFFUSER DIFFUSER AIRFLOW (CFM) kgX -10 TYPE - NECK SIZE RETURN GRILLE /REGISTER 200 RETURN AIRFLOW (CFM) SIZE X - 8 TYPE - NECK Drawn Bv: EXHAUST GRILLE /REGISTER 150 EXHAUST AIRFLOW (CFM) Checked Bv: GS iarlo S-1›-S CONCENTRIC DUCT TRANSITION Jar=21. •..__S ECCENTRIC DUCT TRANSITION @ SMOKE DETECTOR Q THERMOSTAT GENERAL PLUMBING NOTES A. CONTRACTOR SHALL VISIT THE JOB SITE AND FAMILIARIZE THEMSELVES WITH ALL REQUIREMENTS OF THE PROJECT AND NOTIFY THE ENGINEER IMMEDIATELY OF ANY DISCREPANCIES FOUND. THIS SHALL BE DONE PRIOR TO BID TO PREVENT UNKNOWN ADDITIONAL COSTS TO THE OWNER. B. ANY CHANGES AND OR UPGRADE TO TENANT'S EXISTING PLUMBING SYSTEMS SHALL COMPLY WITH ALL CODES AND MALL CRITERIA. EXISTING SYSTEMS SHALL POSSES THE CAPACITY TO HANDLE ANY ALL CHANGES IN LOAD. C. BEFORE CORE DRILLING OR CHANNELING THE FLOOR SLAB, THE CONTRACTOR SHALL X -RAY THE AREA UNDER CONSTRUCTION FOR PIPES HIDDEN WITHIN OR BELOW THE SLAB. ANY DAMAGE TO EXISTING TO REMAIN SERVICES TO BE REPAIRED AT CONTRACTOR EXPENSE. D. COORDINATE WITH PROPERTY MANAGEMENT PRIOR TO REMOVAL OF ALL EXISTING FLOOR SLAB AND THE CONNECTION BETWEEN NEW AND EXISTING SERVICES. E. REFER TO THE ARCHITECTURAL DRAWINGS FOR WALL ELEVATIONS FOR MOUNTING HEIGHTS FOR ALL PLUMBING FIXTURES. F. ALL SHUTOFF VALVES SHALL BE ACCESSIBLE. DO NOT LOCATED ANY VALVES ABOVE DUCTWORK, ELECTRICAL CONDUIT, CABLE TRAYS OR PIPING THAT WOULD MAKE THE VALVES INACCESSIBLE OR UNABLE TO VISUAL SEE THE VALVES LOCATION. LOCATE THE BRANCH SHUTOFF VALVES AS CLOSE AS POSSIBLE TO THE BRANCH CONNECTION TO THE MAIN SERVICE WHILE MAINTAINING THE VALVE ACCESSIBILITY. ABOVE CEILING VALVES TO BE LOCATED NEAR CEILING ACCESS PANELS. G. THE PLUMBING CONTRACTOR TO PROVIDE ALL PIPING, SINK TAILPIECES, SINK DRAIN FITTINGS, AND ALL OTHER MISC FITTINGS AS REQUIRED. H. PROVIDE DEEP SEAL P -TRAP FOR ALL FLOOR DRAINS. I. PROVIDE ADDITIONAL FLOOR CLEANOUTS OR WALL CLEANOUTS AS DIRECTED BY THE ADMINISTRATIVE AUTHORITY. J. INSTALL BALL VALVES ON ALL BRANCH SUPPLY LINES. K. INSULATE ALL EXPOSED PIPING UNDER CABINETS AND LAVATORY SINKS. L. SLEEVE AND SEAL ALL FLOOR PENETRATIONS LIQUID TIGHT AND INSTALL WATERPROOF FLOOR MEMBRANE - ALL PLUMBING AREAS. LEGEND w w.mm= GW 11•111•1111MGW� —v— - CW —cw FCW scw HW -G — —G 0 EXISTING SANITARY WASTE NEW SANITARY WASTE EXISTING GREASE WASTE NEW GREASE WASTE NEW VENT COLD WATER PIPING (EXISTING) COLD WATER PIPING (CW) FILTERED COLD WATER PIPING (FCW) SOFT COLD WATER PIPING (SCW) HOT WATER PIPING 115E (HW) GAS (EXISTING) GAS GAS PIPING ON ROOF CONNECT EXISTING .04-1 OS I 2 PLUMBING PLAN 1/4" = 1' -O" DOMESTIC WATER RISER DIAGRAM NOT TO SCALE WH -1 P -1 P -1 C6j WASTE AND VENT RISER DIAGRAV1 NOT TO SCALE PLUMBING PLAN NOTES O1 INSTALL NEW TANK WATER HEATER ON SHELF ABOVE MOP SINK, SEE ARCHITECTURAL SHEETS FOR DETAIL, O TOILET ROOM AND PLUMBING FIXTURES TO REMAIN - VERIFY CONDITION IN FIELD AND PROVIDE NEW AS REQUIRED. O CONNECT NEW 3/4" CW PIPING TO EXISTING CW PIPING, VERIFY ROUTING AND SIZE ON SITE. O CONNECT NEW 1 1/2" SANITARY VENT PIPING TO EXISTING SANITARY VENT PIPING, VERIFY ROUTING AND SIZE ON SITE. O CONNECT NEW 3" SANITARY WASTE PIPING TO EXISTING SANITARY WASTE PIPING, VERIFY ROUTING AND SIZE ON SITE. HVAC REFURBISHING REQUIREMENTS 1. THE MECHANICAL CONTRACTOR SHALL PERFORM SERVICE AND REPAIR OF THE EXISTING FAN COIL UNIT AND ITS ACCESSORIES AS FOLLOWS, BUT ARE NOT LIMITED TO: CLEAN ALL COILS, REPLACE THE FILTERS AND BELTS, INSPECT, REPAIR OR REPLACE DRIVES, FAN BEARINGS, MOTORS, CONTROL COMPONENTS, VALVES AND ANY OTHER ITEM NECESSARY FOR A COMPLETE AND PROPER OPERATING SYSTEM. THIS CONTRACTOR SHALL ALSO VISIT THE SITE PRIOR TO BIDDING AND VERIFY ALL EXISTING SITE CONDITIONS. 2. ALL WORK, EQUIPMENT, AND ACCESSORIES TO BRING EXISTING SYSTEM TO GOOD WORKING CONDITION SHALL BE COVERED UNDER CONTRACTOR'S ORIGINAL BID AND AT NO ADDITIONAL EXPENSE. CONTRACTOR SHALL VERIFY ALL ON SITE CONDITIONS PRIOR TO BID. MECHANICAL GENERAL NOTES A. INSTALL VOLUME DAMPER IN DUCT TAKE -OFF TO EACH DIFFUSER, GRILLE, AND REGISTER. B. ALL DUCT DIMENSIONS ARE CLEAR INSIDE DIMENSIONS. CONTRACTOR MAY, AT HIS OPTION, REPLACE RECTANGULAR DUCTWORK SHOWN WITH ROUND, SPIRAL DUCT OF EQUIVALENT CAPACITY. C. IN GENERAL, ALL PIPING AND DUCTWORK SHALL BE RUN CONCEALED IN SUSPENDED CEILING SPACES AND IN SHAFTS PROVIDED UNLESS NOTED OR INDICATED OTHERWISE. D. VERIFY ALL DUCT CONNECTION SIZES TO FANS, COILS, AND EXISTING DUCTWORK. E. COOPERATE WITH THE OTHER TRADES TO ELIMINATE ANY CONFLICTS BETWEEN PIPING, DUCTWORK, STRUCTURAL, ELECTRICAL WORK, ETC. F. DIFFUSER, REGISTER, AND SPRINKLER HEAD LOCATIONS SHALL BE COORDINATED WITH LIGHT FIXTURE LOCATIONS AND SHALL BE IN ACCORDANCE WITH CEILING PATTERNS AS SHOWN ON ARCHITECTURAL REFLECTED CEILING PLANS. G. ALL SQUARE DIFFUSERS SHALL HAVE THE AIR VOLUME EQUALLY IN FOUR DIRECTIONS UNLESS INDICATED OTHERWISE. H. MECHANICAL CONTRACTOR TO VERIFY RATINGS OF ALL WALLS WITH ARCHITECTURAL DRAWINGS. SEAL PIPE PENETRATIONS TO MATCH THE WALL RATINGS. PROVIDE ALL SUPPLY AND RETURN DUCTS PASSING THROUGH FIRE RATED WALLS WITH APPROVED FIRE DAMPERS AS REQUIRED. I. RUNOUTS TO DIFFUSERS SHALL BE THE SAME SIZE AS THE DIFFUSERS NECK SIZE. J. TENANTS CONTRACTORS SHALL VERIFY WITH HVAC PLAN TO COORDINATE THE REQUIREMENT OF PLENUM RATED FIXTURES, PIPING, WIRING, ETC. FAILURE TO DO SO COULD RESULT IN THE REMOVAL AND REPLACEMENT OF THESE ITEMS AT NO ADDITIONAL COST TO THE TENANT - NO PVC PIPING ALLOWED IN PLENUM. K. CONTRACTOR SHALL STENCIL TENANT NAME AND SPACE NUMBER ON UNIT. L. THE TENANTS MECHANICAL CONTRACTOR SHALL GO TO THE SITE AND VERIFY THE SIZE, DESIGN, SUPPORT AND LOCATION FOR ALL EXISTING AND FUTURE MECHANICAL EQUIPMENT AND UTILITY TAPS PRIOR TO ANY EQUIPMENT ORDERING, WORK, DUCTWORK FABRICATION ETC. NOTIFY THE TENANTS PROJECT MANAGER OR PROJECT ENGINEER IMMEDIATELY WITH ANY DISCREPANCIES. FAILURE TO DO SO COULD RESULT IN EQUIPMENT AND /OR MATERIALS REPLACEMENT AT NO ADDITIONAL EXPENSE TO THE TENANT. M. ALL EQUIPMENT, INSTALLATIONS, AND MATERIAL SHALL COMPLY WITH ALL APPLICABLE LOCAL CODES AND LANDLORD CRITERIA. N. REMOVE ALL UNUSED PIPING, DUCTWORK, AND ACCESSORIES - DO NOT ABANDON. 0. VERIFY LOCATION OF ANY PENETRATION THRU ROOF WITH LANDLORD. ALL ROOF PENETRATIONS, PATCHING, AND FLASHING SHALL BE BY LANDLORD'S ROOFER AT MECHANICAL CONTRACTOR EXPENSE. P. PRIOR TO OCCUPANCY OF THE PREMISES, GENERAL CONTRACTOR IS REQUIRED TO PROVIDE AN AIR BALANCE REPORT. A MALL APPROVED, INDEPENDENT, CERTIFIED AIR - BALANCE COMPANY MUST PERFORM THE TEST REPORT. PROVIDE COPY TO MALL OPERATIONS DIRECTOR. FILE COPY Permit No. P , 0 /ill Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved F Id Copy and F ' • di • s is acknowledged: City Of Tukwila BUILDING DIVISION HVAC PLA\ NOTES EXISTING SPLIT SYSTEM WITH DUCT HEATER AND ALL ASSOCIATED ACCESSORIES AND CONTROL COMPONENTS TO BE REUSED - BALANCE AHU -1 TO 1800 CFM SA AND 350 CFM MIN. OA. VERIFY EXACT LOCATION IN FIELD - SEE REFURBISHING NOTE FOR ADDITIONAL REQUIREMENTS. GC TO PROVIDE ACCESS PANELS AS REQUIRED FOR SERVICE OF SPLIT - SYSTEM. O2 EXISTING DUCTWORK TD REMAIN. CAP AND SEAL ALL UNUSED RUN -OUTS AIRTIGHT. PROVIDE NEW INSULATION AS REQUIRED TO ENSURE COMPLETE COVERAGE. O3 MODIFY EXISTING DUCTWORK AS REQUIRED FOR RELOCATED DIFFUSER /GRILLE LOCATION. VERIFY EXACT SIZE AND ROUTING IN FIELD. 4O EXISTING THERMOSTAT TO BE RELOCATED AND REUSED. VERIFY CONDITION IN FIELD PRIOR TO REUSE - MOUNT 48" A.F.F. O5 EXISTING ELECTRIC DUCT HEATER TO BE REUSED. SEE REFURBISHING NOTES FOR ADDITIONAL REQUIREMENTS. PROVIDE ACCESS PANEL(S) AS REQUIRED FOR SERVICE OF DUCT HEATER. O6 EXISTING EXHAUST FAN TO BE REUSED - VERIFY FAN IS CAPABLE OF 100 CFM EXHAUST AIR AND PROVIDE NEW AS REQUIRED. O7 EXISTING RETURN AIR PLENUM WITH BALANCING DAMPERS TO BE REUSED AND REBALANCED. VERIFY ALL CONDITIONS ON SITE. EXISTING OUTDOOR AIR DUCT TO BE REUSED, VERIFY ALL CONDITIONS ON SITE. IF YOU HAVE ANY QUESTIONS REGARDING THE MECHANICAL PLANS, PLEASE CALL THE MECHANICAL DESIGNER. DESIGNER: PHONE /FAX: E —MAIL: TODD BARNES 612 -465- 7685/612- 465 -7785 todd.barnes @dunhameng.com R ODELED /RESTR❑ ❑M I) HVAC PLA\ 1/4" = V-0" ref ocsitgagioticE—OOR APDQOVID Ali, 0 9.201 Of BUILDING SEPARATE PERMIT REQUIRED FOR: ) Mechanical Electrical Q Plumbing 'Gas Piping City of Tukwila BUILDING DIVISION RECEIVED AUG 03 2010 PERMIT CENTER DIFFUSER, GRILLE & REGISTER SCHEDULE DIFF. TAG MOUNTING TYPE DESCRIPTION FINISH MANUF MODEL NO 6/29/10 SIZE NOTES: A LAY -IN SUPPLY WHITE EXISTING EXISTING X 24" X 24" 1 B LAY -IN RETURN WHITE EXISTING EXISTING 24" X 24" 1 NOTES: SUPPLY DIFFUSER /RETURN GRILLE TO REMAIN - REBALANCE AS SHOWN. - REPLACE WITH LIKE MODEL AS REQUIRED PER SITE CONDITIONS. BRING TO 'LIKE -NEW' 1. EXISTING CONDITION DUNHAM Dunham Associates, Inc. 50 South Sixth Street / Suite 1100 Minneapolis, Minnesota 55402 -1540 PHONE 612.465.7550 FAX 612.465.7551 WEB dunhameng.corn mechanical + electrical consulting engineering MBA .Architects, Inc. 3823 Creekside Lane Holmen, WI 54636 608 - 785 -2760 FAX:608- 785 -2750 http://www.mba-architects.com PROJECT NAME: FRANCESCA'S COLLECTIONS PROJECT ADDRESS: SOUTH CENTER MALL TUKWILA, WA CLIENT NAME: FRANCESCA'S COLLECTIONS rancesca C O L L E C T 1 0 .4 PROJECT MANAGER: DATE LANDLORD I CONTRACTOR I 1 VENDOR REVISION l COMMENTS 6/29/10 X X MALL REVIEW 7/7/10 X X FINAL REVIEW 7/14/10 X X X PERMIT Drawn Bv: TB Checked Bv: GS THIS SHEET CONTAINS: HVAC PLAN 0411995 -012 M1 DIVISION 15000 - MECHANICAL SECTION 15001 - BASIC MECHANICAL REQUIREMENTS A. GENERAL CONDITIONS 1. DRAWINGS AND GENERAL PROVISIONS OF CONTRACT, INCLUDING GENERAL AND SUPPLEMENTARY CONDITIONS AND ALL OTHER SPECIFICATION SECTIONS, APPLY TO THIS AND THE OTHER SECTIONS OF DIVISION 15000. 2. THE CONTRACTOR FOR THIS DIVISION OF WORK IS REQUIRED TO READ THE SPECIFICATIONS AND REVIEW DRAWINGS FOR ALL DIVISIONS OF WORK AND IS RESPONSIBLE FOR THE COORDINATION OF THEIR WORK AND THE WORK OF THEIR SUBCONTRACTORS WITH ALL DIVISIONS OF WORK. IT IS THIS CONTRACTORS RESPONSIBILITY TO PROVIDE THEIR SUBCONTRACTORS WITH A COMPLETE SET OF BID DOCUMENTS. 3. THIS CONTRACTOR IS RESPONSIBLE FOR SCHEDULING THE COMPLETION AND 'INSPECTION OF THEIR WORK AND THE WORK OF THEIR SUBCONTRACTORS TO COMPLY WITH THE SCHEDULE AND THE PROJECT COMPLETION DATE. 4. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO SUBMITTAL OF BID TO DETERMINE CONDITIONS AFFECTING THE WORK. ANY ITEMS WHICH ARE NOT COVERED IN THE BID DOCUMENTS OR ANY PROPOSED SUBSTITUTIONS SHALL BE LISTED SEPARATELY AND QUALIFIED IN THE CONTRACTORS BID. SUBMITTAL OF BID SHALL SERVE AS EVIDENCE OF KNOWLEDGE OF EXISTING CONDITIONS AND ANY MODIFICATIONS WHICH ARE REQUIRED TO MEET THE INTENT OF THE DRAWINGS AND SPECIFICATIONS. FAILURE TO VISIT THE SITE DOES NOT RELIEVE THE CONTRACTOR OF RESPONSIBILITY IN PERFORMANCE OF WORK. 5. REFER. TO RESPONSIBILITY SCHEDULE FOR INFORMATION IN REGARD TO RESPONSIBILITY OF WORK OR ITEMS WHICH MAY AFFECT BID. SECTION 15002 - GENERAL REQUIREMENTS 1. THIS CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIALS, EQUIPMENT, SERVICES, TOOLS, TRANSPORTATION, INCIDENTALS AND DETAILS NECESSARY TO PROVIDE A COMPLETE MECHANICAL SYSTEM AS SHOWN ON THE DRAWINGS, CALLED FOR IN THE SPECIFICATIONS, AND AS REQUIRED BY JOB CONDITIONS. ALL WORK NOT SPECIFICALLY NOTED AS BEING BY THE LANDLORD OR TENANT SHALL BE PROVIDED BY THE MECHANICAL CONTRACTOR. CLOSELY COORDINATE THE ENTIRE INSTALLATION WITH THE LANDLORD AND THE TENANT PROJECT MANAGER, AS REQUIRED. 2. THE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO SUPPLEMENT EACH OTHER AND ANY MATERIAL OR LABOR CALLED FOR IN ONE SHALL BE FURNISHED AND INSTALLED EVEN THOUGH NOT SPECIFICALLY MENTIONED IN BOTH. ANY MATERIAL OR LABOR WHICH IS NEITHER SHOWN ON THE DRAWINGS NOR CALLED FOR IN THE SPECIFICATIONS, BUT WHICH IS OBVIOUSLY NECESSARY TO COMPLETE THE WORK, AND WHICH IS USUALLY INCLUDED IN WORK OF SIMILAR CHARACTER, SHALL BE FURNISHED AND INSTALLED AS PART OF CONTRACT. 3. WHERE THE DRAWINGS OR SPECIFICATIONS CALL FOR ITEMS WHICH EXCEED CODES OR THE LANDLORD'S TENANT CRITERIA, THE CONTRACTOR IS RESPONSIBLE FOR FURNISHING AND INSTALLING THE SYSTEM WITH THE MORE STRINGENT REQUIREMENTS AS DESIGNED AND DESCRIBED ON THESE DRAWINGS, UNLESS SPECIFICALLY NOTED OTHERWISE. 4. ALL MECHANICAL WORK SHALL BE INSTALLED SO AS TO BE READILY ACCESSIBLE FOR OPERATING, SERVICING, MAINTAINING, AND REPAIRING. THIS CONTRACTOR IS RESPONSIBLE FOR PROVIDING ACCESS PANELS FOR SUFFICIENT SERVICE ACCESS TO ALL EQUIPMENT. 5. ALL WORK SHALL BE PERFORMED IN A NEAT PROFESSIONAL MANNER USING, GOOD ENGINEERING AND CONSTRUCTION PRACTICES. 6. UNLESS SPECIFICALLY NOTED OTHERWISE, MATERIALS, PRODUCTS, AND EQUIPMENT, INCLUDING ALL COMPONENTS THEREOF, SHALL BE NEW, UNDERWRITERS LABORATORIES LISTED AND LABELED AND SIZED IN CONFORMITY WITH REQUIREMENTS OF STATE AND LOCAL CODES, WHICHEVER IS MORE STRINGENT. SECTION 15003 - CODES 1. ALL WORK SHALL CONFORM TO THE LANDLORDS' CRITERIA, THE STATE'S, COUNTY'S, CITY'S AND LOCAL CODES AND ORDINANCES, SAFETY AND HEALTH CODES, NFPA CODES, ENERGY CODES AND ALL OTHER, APPLICABLE CODES AND REQUIREMENTS. THIS CONTRACTOR SHALL INQUIRE INTO AND COMPLY WITH ALL APPLICABLE CODES, ORDINANCES, AND REGULATIONS. THIS CONTRACTOR SHALL INCLUDE ANY CHANGES REQUIRED BY CODES IN THE BID AND IF THESE CHANGES ARE NOT INCLUDED IN THE BID, THEY MUST BE QUALIFIED AS A SEPARATE LINE ITEM IN THE BID. AFTER CONTRACT IS ISSUED, NO ADDITIONAL COST DUE TO CODE ISSUES SHALL BE REIMBURSED BY TENANT. TO THE CONTRACTOR. SECTION 15004 - LICENSES, PERMITS, INSPECTIONS & FEES 1. THIS CONTRACTOR SHALL OBTAIN AND PAY FOR ALL LICENSES, PERMITS, INSPECTIONS, AND FEES REQUIRED OR RELATED TO THEIR WORK. 2. FURNISH TO TENANT'S PROJECT MANAGER ALL CERTIFICATES OF INSPECTION AND FINAL INSPECTION APPROVAL AT COMPLETION OF PROJECT. SECTION 15005 - TRADE NAMES, MANUFACTURERS AND SHOP DRAWINGS 1. WHERE TRADE NAMES AND MANUFACTURERS ARE USED ON THE DRAWINGS OR IN THE SPECIFICATIONS, THE EXACT EQUIPMENT SHALL BE USED AS A MINIMUM FOR THE BASE BID. MANUFACTURERS CONSIDERED AS AN EQUAL OR BETTER IN ALL ASPECTS TO THAT SPECIFIED WILL BE SUBJECT TO APPROVAL IN WRITING BY TENANT'S PROJECT MANAGER THROUGH PRIOR SHOP DRAWING SUBMITTAL PROCESS, FOR ACCEPTANCE. THE USE OF ANY UNAUTHORIZED EQUIPMENT SHALL BE SUBJECT TO REMOVAL AND REPLACEMENT AT THE CONTRACTOR'S EXPENSE. 2. MECHANICAL CONTRACTOR SHALL SUBMIT ONLY SUBSTITUTION REQUESTS TO TENANT'S PROJECT MANAGER FOR APPROVAL. SUBMISSIONS SHALL BE MADE EARLY ENOUGH IN PROJECT TO ALLOW FOUR (4) WORKING DAYS FOR TENANT'S PROJECT MANAGER'S REVIEW WITHOUT CAUSING DELAYS OR CONFLICTS TO THE JOB'S PROGRESS. SUBMITTALS SHALL BEAR THE STAMP OF GENERAL CONTRACTOR AND THE SUB - CONTRACTOR SHOWING THAT THEY HAVE REVIEWED AND CONFIRMED THAT THE SUBMITTALS ARE IN CONFORMANCE WITH THE CONTRACT DRAWINGS AND SPECIFICATIONS OR INDICATE WHERE EXCEPTIONS HAVE BEEN TAKEN. SECTION 15006 - GUARANTEE 1. THIS CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORK PROVIDED UNDER THEIR CONTRACT AND SHALL MAKE GOOD, REPAIR OR REPLACE AT THEIR OWN EXPENSE, ANY DEFECTIVE WORK, MATERIAL, OR EQUIPMENT WHICH MAY BE DISCOVERED WITHIN A PERIOD OF 12 MONTHS FROM THE DATE OF ACCEPTANCE (IN WRITING) OF THE INSTALLATION BY TENANT'S PROJECT MANAGER. EXTENDED WARRANTIES ARE AS SPECIFIED WITH INDIVIDUAL EQUIPMENT. SECTION 15007 - RECORD DRAWINGS 1. THIS CONTRACTOR SHALL MAINTAIN ONE COPY OF DRAWINGS ON THE JOB SITE TO RECORD DEVIATIONS FROM CONTRACT DRAWINGS, SUCH AS: A. LOCATION OF CONCEALED PIPING VALVES AND DUCTS. B. REVISIONS, ADDENDUMS, AND CHANGE ORDERS. C. SIGNIFICANT DEVIATIONS MADE NECESSARY BY FIELD CONDITIONS, APPROVED EQUIPMENT SUBSTITUTIONS, AND CONTRACTOR'S COORDINATION WITH OTHER TRADES. 2. AT COMPLETION OF THE PROJECT AND BEFORE FINAL APPROVAL, THE CONTRACTOR SHALL MAKE ANY FINAL CORRECTIONS TO DRAWINGS AND CERTIFY THE ACCURACY OF EACH PRINT BY SIGNATURE THEREON. ONE COPY OF THE MOST RECENT SET OF DRAWINGS WITH TEMPERATURE CONTROL DRAWINGS INCLUDED SHALL BE DELIVERED TO TENANT'S PROJECT MANAGER. SECTION 15008 - DISCREPANCIES IN DOCUMENTS 1. DRAWINGS (PLANS, SPECIFICATIONS, AND DETAILS) ARE DIAGRAMMATIC AND INDICATE THE GENERAL LOCATION AND INTENT OF THE MECHANICAL SYSTEMS. WHERE DRAWINGS, EXISTING SITE CONDITIONS, SPECIFICATIONS OR OTHER TRADES CONFLICT OR ARE UNCLEAR, ADVISE TENANT'S PROJECT MANAGER, IN WRITING, OF VARIATIONS TO CONTRACT DOCUMENTS PRIOR TO SUBMISSION OF BID. OTHERWISE, TENANT'S PROJECT MANAGER'S INTERPRETATION OF CONTRACT DOCUMENTS OR CONDITIONS SHALL BE FINAL WITH NO ADDITIONAL COMPENSATION PERMITTED. SECTION 15009 DEMOLITION 1. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION OF THE DEMOLITION OF EXISTING WORK AND THE DEMOLITION PROVIDED BY THE GENERAL CONTRACTOR. COORDINATE WITH THE GENERAL CONTRACTOR ANY EXISTING EQUIPMENT REQUIRED TO BE LEFT INTACT. 2. EACH CONTRACTOR SHALL VERIFY SCOPE OF WORK WITH THE GENERAL CONTRACTOR FOR THE REMOVAL OF ALL EXISTING FIRE PROTECTION, PLUMBING FIXTURES, PIPING, HVAC UNITS, REFRIGERANT RECAPTURE, EXHAUST FANS, ETC. AND ASSOCIATED ROOF CURBS NOT BEING REUSED ON THIS PROJECT, UNLESS SPECIFICALLY NOTED OTHERWISE. CONTRACTOR MUST VERIFY WITH THE LANDLORD ALL PRESUMED ABANDONED EQUIPMENT, PIPES, DUCTWORK, AND EQUIPMENT PRIOR TO REMOVAL. ROOF CURBS SHALL BE REMOVED AND THE ROOF PATCHED. ALL EXTRANEOUS ITEMS IN THE SPACE OR ON THE ROOF NOT APPLICABLE TO THE NEW WORK MUST BE REMOVED AND ROOF /WALL /FLOOR PATCHED /REPAIRED TO MATCH EXISTING STRUCTURE. EXISTING ABANDONED PIPES, DUCTS, OR EQUIPMENT IN THE FLOOR, EMBEDDED IN CONCRETE, OR OTHERWISE INACCESSIBLE ARE TO BE CUT OFF AND SEALED BELOW OR WITHIN FLOOR OR WALL LEVEL WHEN THEY ARE NOT TO BE REUSED IN THIS PROJECT. IF REQUIRED BY LANDLORD OR CODES, ABANDONED PIPING AND /OR DUCTWORK MUST BE REMOVED TO POINT OF ORIGIN. CONFIRM THE EXTENT OF DEMOLITION WITH THE GENERAL CONTRACTOR AND TENANT PRIOR TO BID AND INCLUDE IN BID PROPOSAL AS DIRECTED BY THE GENERAL CONTRACTOR AND TENANT. SECTION 15010 - CUTTING AND PATCHING 1. THE CONTRACTOR SHALL PERFORM ALL CUTTING AND PATCHING AS REQUIRED FOR THE INSTALLATION OF THE WORK UNDER THIS SPECIFICATION. NO CUTTING OF THE STRUCTURE SHALL BE PERMITTED WITHOUT WRITTEN APPROVAL OF THE LANDLORD AND ARCHITECT OR ENGINEER. 2. PATCHING SHALL BE OF THE SAME WORKMANSHIP, MATERIAL AND FINISH AND SHALL MATCH ACCURATELY ALL SURROUNDING CONSTRUCTION IN A MANNER SATISFACTORY TO THE ARCHITECT AND TENANT'S PROJECT MANAGER. 3. EXISTING UTILITIES, ETC. THAT ARE DAMAGED DURING THE CONSTRUCTION PERIOD, WHETHER OR NOT DUE TO THE CONTRACTOR'S NEGLIGENCE SHALL BE REPAIRED OR REPLACED BY THE CONTRACTOR AND LEFT IN A CONDITION SUITABLE TO THE LANDLORD AND TENANT'S PROJECT MANAGER. SECTION 15011 - SLEEVES 1. THIS CONTRACTOR SHALL PROVIDE SLEEVES TO PROTECT EQUIPMENT OR FACILITIES IN THE INSTALLATION. EACH SLEEVE SHALL EXTEND THROUGH IT'S RESPECTIVE FLOOR, WALL OR PARTITION AND SHALL BE CUT FLUSH WITH EACH SURFACE EXCEPT SLEEVES THAT PENETRATE THE FLOOR, WHICH SHALL EXTEND 2" ABOVE THE FLOOR. CONTRACTOR MUST COORDINATE THROUGH THE LANDLORD ANY CORE DRILLING OR CUTTING OF OPENINGS IN MASONRY FLOORS OR WALLS. 2. ALL SLEEVES AND OPENINGS THROUGH FIRE RATED WALLS AND /OR FLOORS SHALL BE FIRE SEALED WITH CALCIUM SILICATE, SILICONE "RTV" FOAM, "3M" FIRE RATED SEALANTS OR EQUAL, SO AS TO RETAIN THEIR FIRE RATING. 3. SLEEVES IN BEARING AND MASONRY WALLS, FLOORS, AND PARTITIONS SHALL BE STANDARD WEIGHT STEEL PIPE FINISHED WITH SMOOTH EDGES. FOR OTHER THAN MASONRY PARTITIONS, THROUGH SUSPENDED CEILINGS, OR FOR CONCEALED VERTICAL PIPING, SLEEVES SHALL BE NO. 22 U.S.G. GALVANIZED STEEL MINIMUM. SECTION 15012 - HANGERS 1. HANGERS SHALL INCLUDE ALL MISCELLANEOUS STEEL SUCH AS ANGLE IRON, BANDS, C- CLAMPS WITH RETAINING CLIPS, CHANNELS, HANGER RODS, ETC., NECESSARY FOR THE INSTALLATION OF WORK. 2. HANGERS SHALL BE FASTENED TO BUILDING STEEL, CONCRETE, OR MASONRY, BUT NOT TO PIPING. HANGING FROM METAL DECK IS NOT PERMITTED. HANGERS MUST BE ATTACHED TO UPPER CHORD OF BAR JOIST. WHERE INTERFERENCES OCCUR, AND IN ORDER TO SUPPORT DUCTWORK OR PIPING, THE CONTRACTOR MUST INSTALL TRAPEZE TYPE HANGERS OR SUPPORTS WHICH SHALL BE LOCATED WHERE THEY DO NOT INTERFERE WITH ACCESS TO FIRE DAMPERS, VALVES, AND OTHER EQUIPMENT. HANGER TYPES AND INSTALLATION METHODS ARE ALSO SUBJECT TO LANDLORD CRITERIA. 3. HANGERS FOR ALL INSULATED PIPING SHALL BE SIZED AND INSTALLED FOR THE OUTER DIAMETER OF INSULATION. INSTALL 6" LONG SPLIT CIRCLE GALVANIZED SADDLE BETWEEN THE HANGER AND THE PIPE INSULATION. 4. HANGERS AND PIPING OF DISSIMILAR METALS SHALL BE DI- ELECTRICALLY SEPARATED. DIVISION 15300 - FIRE PROTECTION (IF APPLICABLE) SECTION 15301 - SUMMARY OF WORK A. THIS CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, EQUIPMENT, ETC. NECESSARY FOR, REASONABLY IMPLIED AND INCIDENTAL TO, THE FURNISHING, INSTALLATION, COMPLETION AND TESTING OF ALL THE WORK FOR THE SPRINKLER SYSTEMS AS CALLED FOR IN THE SPECIFICATIONS, AND AS REQUIRED BY JOB CONDITIONS, TO INCLUDE, BUT NOT BE LIMITED TO THE FOLLOWING: 1. INSTALLATION OF NEW WET SPRINKLER SYSTEM AS REQUIRED TO PROVIDE COVERAGE IN ACCORDANCE , NFPA -13, LOCAL CODES, AND LANDLORD'S CRITERIA. 2. TAPS, RISERS, LATERALS, BRANCHES, VALVES, ALARMS, SPRINKLER HEADS AND ALL COMPONENTS REQUIRED FOR A COMPLETE SYSTEM. 3. DESIGN DRAWINGS, HYDRAULIC CALCULATIONS, SUBMITTALS AND APPROVALS. 4. PERMITS, FEES, INSPECTIONS AND CHARGES. 5. TESTS AND TEST CERTIFICATES. IT IS INTENDED THAT THE CONTRACTOR SHALL PROVIDE A COMPLETE AND FUNCTIONAL SYSTEM. B. THIS FIRE PROTECTION CONTRACTOR IS RESPONSIBLE FOR SUBMITTING COORDINATED DRAWINGS, HYDRAULIC CALCULATIONS, HEAD TYPES AND COLORS TO ALL AUTHORITIES HAVING JURISDICTION FOR APPROVAL. NO WORK SHALL BEGIN UNTIL ALL APPROVALS HAVE BEEN RECEIVED. SECTION 15302 - MATERIALS A. SPRINKLER HEADS: 1. ALL SPRINKLER HEADS SHALL BE NEW U.L., F.M. LISTED AND APPROVED AUTOMATIC SPRAY TYPE AS MANUFACTURED BY GRINNELL, RELIABLE, STAR, OR VIKING. 2. ALL SPRINKLER HEADS SHALL BE RATED FOR 165T UNLESS INDICATED OTHERWISE ON DRAWINGS OR REQUIRED BY LOCAL CODES. 3. VERIFY HEAD TYPES AND COLORS WITH TENANT AND SUBMIT WITH SPRINKLER DRAWINGS FOR PERMIT. 4. LOCATIONS OF ALL HEADS SHOULD BE APPROVED BY TENANT AND THE LOCAL FIRE PROTECTION OFFICIAL BEFORE INSTALLATION. A. SALES /TOILET ROOMS AT GYP. BD. CLG - FULLY RECESSED WITH COVER PLATES TO MATCH GYP. BD. FINISH. B. SALES AREA AT A.C.T. CLG. - SEMI - RECESSED CHROME WITH WHITE ESCUTCHEONS. STOCKROOM /CORRIDOR - BRASS PENDANT. STOREFRONT - FULLY RECESSED HEADS WITH COVER PLATES TO MATCH GYP. BD. FINISH.. C. D. B. PIPING: 1. SCHEDULE 40, BLACK STEEL PIPE, ASTM A -53 FOR FERROUS PIPING, WELDED AND SEAMLESS, ANSI B- 36 -10 -70 FOR WROUGHT STEEL PIPE. 2. CAST IRON OR MALLEABLE IRON SCREWED FITTINGS FOR PIPES 2 INCHES AND SMALLER. SCREWED OR CAST IRON FLANGED JOINTS FOR PIPES LARGER THAN 2 INCHES. 3. GALVANIZED OR BLACK MALLEABLE IRON WITH BRASS SEAT SCREWED UNIONS FOR PIPES 2 INCHES AND SMALLER. 4. VICTAULIC TYPE COUPLINGS ARE ACCEPTABLE, WHERE APPROVED BY CODE AND THE LANDLORD. 5. HANGERS SHALL COMPLY WITH LANDLORD AND CODE REQUIREMENTS. C. SPRINKLER SPACING SHALL NOT EXCEED 130 SQ. F. IN "SALES" AREAS AND 100 SQ. FT. IN "STOCK" AREAS. COMPLY WITH LANDLORD'S DESIGN CRITERIA. PIPE SIZING SHALL BE BASED ON NFPA ORDINARY HAZARD. D. ALL SPRINKLER LINES SHALL BE INSTALLED CONCEALED, AVOIDING INTERFERENCE WITH OTHER TRADES. E. WHERE POSSIBLE, REWORK THE EXISTING SPRINKLER SYSTEM TO MEET THE NEW REQUIREMENTS OF THIS DESIGN AND INCLUDE ALL COSTS TO RAISE OR RELOCATE EXISTING PIPING TO OBTAIN CEILING HEIGHTS SHOWN ON DRAWINGS. IN NEW CONSTRUCTION THE LANDLORD MAY PROVIDE ONLY A STUB -IN TO THE SPACE. THE CONTRACTOR SHALL CONNECT AND EXTEND NEW PIPING AS REQUIRED. VERIFY ALL REQUIREMENTS PRIOR TO BID. F. PROVIDE AND INSTALL A VALVED TEST CONNECTION IN AN ACCESSIBLE LOCATION FOR THE SPRINKLER SYSTEM AS REQUIRED OR REQUESTED BY THE MALL, LOCAL INSPECTOR, OR TENANT'S INSURANCE CARRIER. G. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGE CAUSED BY LEAKS IN ANY OF THE EQUIPMENT INSTALLED BY THEM. ALL REPAIRS OR REPLACEMENT OF DAMAGES SHALL BE AT THIS CONTRACTOR'S EXPENSE. H. PROPERLY COMPLETED AND SIGNED "SPRINKLER CONTRACTOR'S MATERIAL AND TEST CERTIFICATES" SHALL BE FURNISHED TO THE LANDLORD, AND AUTHORITIES HAVING JURISDICTION. DIVISION 15400 - PLUMBING SECTION 15401 - SUMMARY OF WORK A. THIS CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, EQUIPMENT, ETC. NECESSARY FOR, REASONABLY IMPLIED AND INCIDENTAL TO, THE FURNISHING, INSTALLATION, COMPLETION AND TESTING OF ALL THE WORK FOR THE PLUMBING SYSTEMS AS CALLED FOR IN THE SPECIFICATIONS, SHOWN ON DRAWINGS AND AS REQUIRED BY JOB CONDITIONS, TO INCLUDE, BUT NOT BE LIMITED TO THE FOLLOWING: 1. CONTRACTOR SHALL DETERMINE THE LOCATION OF EXISTING WATER SUPPLY AND DRAIN LINES AND MAKE PROPER CONNECTIONS, THERETO, INCLUDING VENTS. 2. ALL MATERIALS SHALL BE NEW AND SHALL FIT THE SPACE AVAILABLE. VERIFY ALL DIMENSIONS AT THE SITE. 3. ALL VALVES, CLEANOUTS, ETC. SHALL BE SO LOCATED AND INSTALLED TO PERMIT ACCESS FOR SERVICE WITHOUT DAMAGE TO BUILDING OR FINISHED MATERIALS. SECTION 15402 MATERIALS A. REFER TO PLANS FOR SCHEDULES OF EQUIPMENT AND FIXTURES. AMERICAN STANDARD, KOHLER AND CRANE ARE CONSIDERED ACCEPTABLE AS EQUALS. ALL PLUMBING EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATION. B. SANITARY PIPING 1. WASTE, DRAIN AND VENT PIPING SHALL BE SERVICE WEIGHT CAST IRON HUB AND SPIGOT BELOW; NO HUB ABOVE GROUND. VENT PIPING ABOVE FLOOR 2" OR SMALLER MAY BE GALVANIZED STEEL. 2. INSULATE ALL HORIZONAL RUNS OF PIPING LOCATED IN CEILING SPACES OF TENANTS IN SPACES BELOW, WHEN APPLICABLE. INSULATION TO BE AS SPECIFIED FOR WATER PIPING. 3. INTERIOR CONDENSATE PIPING SHALL BE TYPE "L" HARD DRAWN COPPER TUBE WITH 95 -5 TIN - ANTIMONY SOLDERED JOINTS AND WROUGHT COPPER FITTINGS WITH DIELECTRIC SEPARATION BETWEEN DISSIMILAR METALS. EXTERIOR CONDENSATE PIPING MAY BE SCHEDULE 40 PVC PIPING WITH SOLVENT WELDED FITTINGS IF APPROVED FOR USE BY THE LANDLORD. C. POTABLE WATER PIPING 1. BELOW GRADE:TYPE 'K', ANNEALED TEMPERED COPPER TUBE FOR PIPE SIZES 2 INCHES AND SMALLER. BRAZE ALL JOINTS. 2. ALL OTHER: TYPE 'L' HARD DRAWN COPPER TUBE WITH SWEAT JOINTS AND CAST WROUGHT COPPER FITTINGS AND 95 -5 TIN - ANTIMONY SOLDER. D. PIPING OF DISSIMILAR METALS MUST BE DI- ELECTRICALLY SEPARATED. E. INSULATE ALL HOT WATER, COLD WATER AND INTERIOR CONDENSATE PIPING WITH 1" THICK (K =0.23 © 75 F) PIPE INSULATION WITH AN ALL SERVICE JACKET TO MEET LOCAL CODES AND UL F'LAME SPREAD AND SMOKE DEVELOPED RATINGS. OWENS- CORNING OR EQUAL. F. INSULATE THE TRAP, SANITARY AND SUPPLY PIPES UNDER LAVATORY WITH 1 /2" ARMSTRONG "ARMAFLEX" PIPING INSULATION OR TRUEBRO MODEL 102W WHITE "HANDI LAV GUARD" INSULATION KIT TO COMPLY WITH ADA REQUIREMENTS. G. INSTALL AIR CHAMBER SHOCK ABSORBERS IN BOTH HOT AND COLD LINES OF PIPING SYSTEM TO PREVENT NOISE AND DAMAGE DUE TO WATER HAMMER. SIOUX CHIEF 650 SERIES ALL STAINLESS STEEL, OR EQUAL. J.R. SMITH "HYDROTROLS ", INSTALLED IN AN UPRIGHT POSITION. H. ALL BRANCH PIPING SYSTEM SHALL HAVE ACCESSIBLE SERVICE VALVE. PROVIDE SHUT OFF VALVES IN THE SUPPLY PIPING TO EVERY FIXTURE. PROVIDE ACCESS DOORS WHERE NECESSARY. I. INSTALL ALL NECESSARY PIPE HANGERS, SADDLES, AND CARRIERS TO PROPERLY SUPPORT ALL PIPING AND FIXTURES. HANGERS SHALL SUIT TYPE OF PIPING INSTALLED AND BE SPACED AT A MAXIMUM SPAN OF 5 FEET. PROVIDE SWAY AND SEISMIC BRACING WHERE REQUIRED BY CODES. J. STERILIZE WATER SYSTEM IN ACCORDANCE WITH LOCAL CODES. K. CLEAN -OUTS AND FLOOR DRAINS SHALL BE INSTALLED PER LOCAL CODES. ALL FLOOR DRAINS SHALL HAVE DEEP SEAL TRAPS. PROVIDE TRAP PRIMERS FOR FLOOR DRAINS. L. ESCUTCHEONS SHALL BE CHROME PLATED, SIZE AS REQUIRED AND PLACED AT ALL PIPE PENETRATIONS AT WALLS, FLOORS, AND CEILINGS IN FINISHED AREAS. M. LEAKAGE TESTS SHALL BE PER LOCAL CODES. N. FLASHING SHALL BE SEALED WATERTIGHT AND PERFORMED IN ACCORDANCE TO THE LANDLORD'S CRITERIA. USE A LANDLORD APPROVED ROOFING CONTRACTOR WHERE APPLICABLE AND INCLUDE ALL COSTS IN BID. 0. PROVIDE WATER METER AND REMOTE READER PER LANDLORD'S CRITERIA OR LOCAL UTILITIES REQUIREMENTS IF APPLICABLE. P. GAS PIPING 1. PROVIDE A COMPLETE GAS PIPING SYSTEM IF APPLICABLE. REFER TO PLANS TO DETERMINE IF A GAS SYSTEM IS REQUIRED. 2. GAS LINES SHALL BE BLACK STEEL, SCHEDULE 40, ASTM A -120, WITH MALLEABLE THREADED FITTINGS FOR 2" AND SMALLER, AND WITH WELDED JOINTS FOR 2 -1/2" AND LARGER. 3. PROVIDE A GAS COCK, DIRT LEG, AND UNION CONNECTION TO EACH PIECE OF EQUIPMENT. 4. PITCH PIPING AT A UNIFORM GRADE OF 1/4" IN 15 FEET UPWARD IN DIRECTION OF FLOW. SUPPORT PIPING EVERY 5 FEET. SUPPORT AS REQUIRED BY LANDLORD CRITERIA, AS DETAILED ON DRAWINGS, OR BY STANDARD INDUSTRY PRACTICE, WHICHEVER IS MORE STRINGENT. 5. GAS PIPING EXPOSED ON ROOF MUST BE PRIMED AND PAINTED WITH RUST - INHIBITING PAINT. 6. GAS PIPING INSTALLED IN RETURN AIR PLENUMS SHALL BE SLEEVED AND VENTED OR WELDED IN ACCORDANCE WITH THE LOCAL GAS COMPANY, LOCAL CODE, AND APPLICABLE NFPA 54 CODES. 7. TESTING AND PURGING OF GAS PIPING SHALL BE DONE PER THE REQUIREMENTS OF THE LOCAL GAS COMPANY, LOCAL CODES, AND APPLICABLE NFPA 54 CODES. 8. CONTACT AND COORDINATE GAS SERVICE AND METER REQUIREMENTS WITH THE LOCAL GAS COMPANY AND THE MALL'S OPERATIONS MANAGER PRIOR TO BID. INCLUDE INSTALLATION OF GAS METER AND REGULATOR COSTS IN BID. DIVISION 15500 - HEATING, VENTILATING, AIR CONDITIONING SECTION 15501 - SUMMARY OF WORK A. THIS CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, EQUIPMENT, ETC. NECESSARY FOR, REASONABLY IMPLIED AND INCIDENTAL TO, THE FURNISHING, INSTALLATION, COMPLETION AND TESTING OF ALL THE WORK FOR THE HVAC SYSTEMS AS CALLED FOR IN THE SPECIFICATIONS, SHOWN ON DRAWINGS AND AS REQUIRED BY JOB CONDITIONS, TO INCLUDE, BUT NOT BE LIMITED TO THE FOLLOWING: 1. EXISTING SPLIT- SYSTEM CU -1 & AHU -1 & ELECTRIC DUCT HEATER EDH -1 TO REMAIN. 2. THE AIR DEVICES AS NOTED ON THE PLANS SHALL BE PURCHASED BY THE CONTRACTOR. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SCHEDULING, RECEIVING, VERIFYING QUANTITIES AND INSPECTING FOR DAMAGE AND FILING OF ANY CLAIM FORMS. REFER TO RESPONSIBILITY SCHEDULE AND AIR DEVICE SCHEDULE ON PLANS. 3. ALL MATERIALS SHALL BE NEW AND SHALL FIT THE SPACE AVAILABLE. VERIFY ALL DIMENSIONS AT THE SITE. 4. ALL VALVES, DAMPERS, ETC. SHALL BE SO LOCATED AND INSTALLED TO PERMIT ACCESS FOR SERVICE WITHOUT DAMAGE TO BUILDING OR FINISHED MATERIALS. SECTION 15502 - MATERIALS A. REFER TO PLANS FOR SCHEDULES OF EQUIPMENT. ALL EQUIPMENT SHALL BE COMPLETE IN EVERY RESPECT WITH ALL DEVICES, APPURTENANCES, AND ACCESSORIES PROVIDED TO MEET THE DESIGN INTENT AND OPERATION OF THE SYSTEMS SHOWN ON THE DRAWINGS AND SPECIFIED HEREIN. EQUIPMENT SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. ALL AIR CONDITIONING EQUIPMENT MUST BE TRAPPED IN ACCORDANCE WITH MANUFACTURERS DATA. B. METAL DUCTWORK - NO FIBERGLASS DUCT ALLOWED 1. EXCEPT AS OTHERWISE INDICATED, FABRICATE AND INSTALL RECTANGULAR AND ROUND DUCTWORK WITH GALVANIZED STEEL, IN ACCORDANCE WITH SMACNA "HVAC DUCT CONSTRUCTION STANDARDS" OF THE LATEST EDITION. 2. INSTALL TURNING VANES IN ALL RIGHT ANGLE ELBOWS IN ALL DUCTS. 3. INSTALL RIGID ROUND AND RECTANGULAR METAL DUCT WITH SUPPORT SYSTEMS INDICATED IN SMACNA STANDARDS. PROVIDE SWAY AND SEISMIC BRACING AS REQUIRED BY STATE AND LOCAL CODES OR BY LANDLORD. 4. ALL JOINTS AND SEAMS SHALL BE SEALED WITH UNITED MCGILL DUCT SEALER OR EQUAL A. ALL JOINTS, LONGITUDINAL AND TRANSVERSE SEAMS, AND CONNECTIONS IN DUCTWORK MUST BE SECURELY SEALED USING WELDMENTS; MECHANICAL FASTENERS WITH SEALS, GASKETS, OR MASTICS; MESH AND MASTIC SEALING SYSTEMS; OR TAPES. TAPES AND MASTICS MUST BE LISTED AND LABELED IN ACCORDANCE WITH UL 181A OR UL 181B. ALL LONGITUDINAL AND TRANSVERSE JOINTS, SEAMS AND CONNECTIONS OF SUPPLY AND RETURN DUCTS OPERATING AT STATIC PRESSURES LESS THAN OR EQUAL TO 2" W.G. SHALL BE SECURELY FASTENED AND SEALED WITH WELDS GASKETS, MASTICS (ADHESIVES), MASTIC - PLUS - EMBEDDED FABRIC SYSTEMS OR TAPES INSTALLED IN ACCORDANCE WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS. B. MECHANICAL FASTENERS AND SEALS, MASTICS, OR GASKETS MUST BE USED WHEN CONNECTING DUCTS TO FANS AND OTHER AIR DISTRIBUTION EQUIPMENT. 5. ALL DUCTWORK SHALL BE INSTALLED WITH INSIDE CLEAR DIMENSIONS AS NOTED ON DRAWINGS. WHERE DUCTWORK SIZE IN LARGER THAN CONNECTED DEVICE SMOOTH DUCT TRANSITIONS SHALL BE INSTALLED JUST PRIOR TO DEVICE CONNECTION. C. MEDIUM PRESSURE DUCT 1. WHERE DUCTWORK IS SPECIFICALLY NOTED AS MEDIUM PRESSURE, IT SHALL BE CONSTRUCTED IN ACCORDANCE WITH SMACNA STANDARDS FOR A PRESSURE RATING OF 4 INCHES WATER COLUMN MINIMUM OR LARGER AS REQUIRED BY LANDLORD. 2. ALL GAUGES AND REINFORCEMENT MUST MEET WITH THE LATEST EDITION OF SMACNA STANDARDS FOR MEDIUM PRESSURE DUCT AND WITH THE LANDLORD'S CRITERIA. 3. CONNECTIONS TO THE LANDLORD'S MEDIUM PRESSURE DUCTWORK SHALL BE MADE WITH "LO -LOSS" SADDLE TEE TAPS BY UNITED MCGILL CORP., OR AS OTHERWISE REQUIRED BY THE LANDLORD. 4. ALL OTHER ITEMS FROM METAL DUCTWORK SPECIFICATION SECTION APPLY TO THIS SECTION, WITH THE EXCEPTION THAT ALL MEDIUM PRESSURE DUCTWORK MUST BE WRAPPED INSULATION, NOT LINED. D. FLEXIBLE COLLARS AT EQUIPMENT SHALL BE PROVIDED IN ALL CONNECTIONS BETWEEN VIBRATING EQUIPMENT AND DUCTS OR CASINGS. FLEXIBLE CONNECTIONS SHALL CONSTRUCTED OF NEOPRENE - COATED FLAMEPROOF FABRIC. PROVIDE ADEQUATE JOINT FLEXIBILITY TO ALLOW FOR MOVEMENT AND PREVENT THE TRANSMISSION OF VIBRATION. E. FLEXIBLE AIR DUCT AT AIR DEVICES SHALL BE MIN. R -5 INSULATED CLASS 1 AND RATED FOR THE OPERATING PRESSURE OF THE SYSTEM. DUCT CONSTRUCTION MATERIAL MUST ADHERE TO LOCAL CODES AND LANDLORD'S REQUIREMENTS. F. PROVIDE MANUAL LOCKING QUADRANT VOLUME CONTROL DAMPERS WITH HANDLE OPERATORS IN EACH BRANCH DUCT AND AS SHOWN ON PLANS TO FACILITATE AIR BALANCING. ALL RECTANGULAR DAMPERS IN OUTSIDE AIR, RELIEF AIR, OR RETURN AIR DUCTS ARE TO BE OF OPPOSED BLADE TYPE. G. PROVIDE PRIMARY FIRE DAMPERS WHERE INDICATED OR REQUIRED BY CODES. FIRE DAMPERS SHALL BE UL LABELED. FIRE DAMPERS SHALL HAVE THE BLADES OUT OF THE AIRSTREAM AND A 165 F FUSIBLE LINK, TYPE B, AS MINIMUM. H. DUCTWORK INSULATION 1. INSTALL INSULATION PRODUCTS IN ACCORDANCE WITH MANUFACTURER'S WRITTEN INSTRUCTIONS, AND IN ACCORDANCE WITH RECOGNIZED INDUSTRY PRACTICES. INSULATION MUST COMPLY WITH NFPA 90A. 2. DUCT SIZES SHOWN ON DRAWINGS ARE INSIDE CLEAR DIMENSIONS. ALL SUPPLY AND RETURN AIR DUCTWORK SHALL BE EXTERNALLY INSULATED WITH 1-1/2" THICK, 1-1/2 LB. DENSITY DUCT WRAP WITH VAPOR BARRIER. VAPOR BARRIER IS TO BE MAINTAINED THROUGHOUT DUCT SYSTEM. ALL JOINTS MUST BE TAPED SO THAT NO INSULATION FIBER IS VISIBLE. EXTEND DUCTWORK INSULATION WITHOUT INTERRUPTION THROUGH WALLS, FLOORS, AND SIMILAR PENETRATIONS. 3. ALL ROUND, MEDIUM PRESSURE AND OUTSIDE AIR DUCTWORK SHALL BE EXTERNALLY INSULATED WITH A MINIMUM OF 2" THICK, 1 LB. ,""' DENSITY (R =5.6) DUCT WRAP WITH VAPOR BARRIER. VAPOR BARRIER IS TO BE MAINTAINED THROUGHOUT DUCT SYSTEM. ALL JOINTS MUST BE TAPED SO THAT NO INSULATION FIBER IS VISIBL EXTEND DUCTWORK INSULATION WITHOUT INTERRUPTION THROUGH FLOORS, AND SIMILAR PENETRATIONS. I. TESTING, ADJUSTING, AND BALANCING 1 CONTRACTOR SHALL BALANCE, ADJUST & TEST EQUIPMENT TO PROVIDE DESIGN AIR QUANTITIES AND ASSURE PROPER OPERATION OF SYSTEMS. CONTRACTOR SHALL SUBMIT COPIES OF BALANCE /TEST REPORT TO OWNER FOR REVIEW PRIOR TO COMPLETION OF PROJECT. IF A CERTIFIED TEST AND BALANCE REPORT IS REQUIRED BY LANDLORD, CONTRACTOR SHALL COORDINATE ALL REQUIREMENTS WITH LANDLORD AND LOCAL AUTHORITY HAVING JURISDICTION, CONTRACT DIRECTLY WITH AN APPROVED TESTING AND BALANCING AGENCY, AND PROVIDE COMPLETE REPORT TO OWNER AND LANDLORD. 2. IF REQUIRED BY THE LANDLORD OR THE LOCAL AUTHORITY HAVING JURISDICTION THE BALANCE REPORT SHALL BE ON THE AABC NATIONAL STANDARD REPORT FORMS OR THE NEBB CERTIFIED REPORT FORMS AS PUBLISHED IN THEIR MOST CURRENT EDITIONS AND SHALL INCLUDE AS A MINIMUM THE FOLLOWING INFORMATION: A. AABC OR NEBB CERTIFICATION NUMBER AND SIGNATURE OF BALANCING CONTRACTOR. B. COPY OF A CERTIFICATE OF CONFORMANCE WITH NATIONAL STANDARDS FOR THIS PROJECT. C. INSTRUMENTATION LIST WITH LAST CALIBRATION DATES. D. MAKE AND MODEL NUMBERS OF ALL HVAC EQUIPMENT TESTED. E. AIR CFM AND STATIC PRESSURE READINGS (DISCHARGE AND SUCTION) AS MEASURED BY PITOT TUBE DUCT TRAVERSE AT THE UNIT. F. MOTOR NAMEPLATE DATA WITH ACTUAL FIELD VOLTAGE AND AMPERAGE READINGS FOR EACH LEG. G. MOTOR AND FAN RPMS, SHEAVE SIZES AND BELT SIZES. H. OUTSIDE, RETURN, MIXED AND SUPPLY AIR TEMPERATURES AND VOLUMES SHALL BE MEASURED AT FULL COOLING WITH MINIMUM OUTSIDE AIR. RETURN /RELIEF /SMOKE EVACUATION AIRFLOW SHALL BE BALANCED AND MEASUREMENTS RECORDED BY PITOT DUCT TRAVERSE AT FULL ECONOMIZER AND POWER EXHAUST. I. MAKE AND MODEL NUMBERS OF ALL AIR DISTRIBUTION EQUIPMENT. J. FINAL BALANCED AIR VOLUMES AT ALL OUTLETS (INCLUDING RETURNS WHERE DUCTED). K. INDEXED PLAN WITH DIFFUSER AND RETURN LOCATIONS. ALSO INDICATE IF DIFFUSER IS 3 -WAY OR 2 -WAY. L. FINAL BALANCED GPM AT ALL UNITS FOR CHILLED /HOT /CONDENSER WATER WHEN APPLICABLE. M. CHILLED /HOT /CONDENSER ENTERING AND LEAVING WATER TEMPERATURES WHEN APPLICABLE. N. PRESSURE DROP THROUGH COILS AND CONTROL VALVES WHEN APPLICABLE. 3. IF REQUIRED BY THE LANDLORD OR THE LOCAL AUTHORITY HAVING JURISDICTION THE GENERAL CONTRACTOR SHALL ARRANGE FOR THE TEST AND BALANCE A MINIMUM OF TWO WEEKS PRIOR TO THE REQUIRED DATE AFTER RETURNING TABC'S "START UP CHECK LIST ". ALL WORK SHALL BE COMPLETED PRIOR TO SCHEDULING AIR BALANCE. IN ADDITION, THE BALANCE CONTRACTOR WILL INSPECT AND PREPARE A FINAL PUNCH LIST. THE HVAC CONTRACTOR SHALL REPAIR OR REPLACE ANY DEFECTIVE MATERIALS, EQUIPMENT OR WORKMANSHIP PRIOR TO TENANT'S FINAL WALK THRU AND BEFORE FINAL PAYMENT WILL BE MADE. 4. FOUR COPIES OF THE BALANCE REPORT SHALL BE SUBMITTED TO TENANT AND FOUR COPIES TO THE LANDLORD FOR APPROVAL. 5, OPERATION AND MAINTENANCE DOCUMENTATION MUST BE PROVIDED TO THE OWNER THAT INCLUDES AT LEAST THE FOLLOWING INFORMATION: A. EQUIPMENT CAPACITY (INPUT AND OUTPUT) AND REQUIRED MAINTENANCE ACTIONS. B. EQUIPMENT OPERATION AND MAINTENANCE MANUALS. C. HVAC SYSTEM CONTROL MAINTENANCE AND CALIBRATION INFORMATION, INCLUDING WIRING DIAGRAMS, SCHEMATICS, AND CONTROL SEQUENCE DESCRIPTIONS; DESIRED OR FIELD - DETERMINED SET POINTS MUST BE PERMANENTLY RECORDED ON CONTROL DRAWINGS, AT CONTROL DEVICES, OR, FOR DIGITAL CONTROL SYSTEMS, IN PROGRAMMING COMMENTS. D. COMPLETE NARRATIVE OF HOW EACH SYSTEM IS INTENDED TO OPERATE. REVIEWED FOR CODE COMPLIANCE VALLSi!/�� "�PP VFD AUG 0 9 2010 BUILDING Tukwila I ALL PIPING SHALL WITHSTAND AIR PRESSURE TESTING PER GOVERNING PLUMBING CODE. ?c,io- 097 RECEIVED AUG 03 2010 PERMIT CENTER ELECTRIC WATER HEATER SCHEDULE TAG MANUFACTURER MODEL NO. KW VOLTS NOTES WH -1 A.O. SMITH DEL -6 1.5 SEE ELEC 6 GALLON, 40 DEG TEMP. RISE PLUMBING FIXTURE SCHEDULE MARK TYPE MANUFACTURE AND MODEL NUMBER SUPPORT W V CW HW REMARKS P1 MOP SINK BASIN FLORESTONE MSR -2424 (MOLDED STONE) FLOOR MOUNT 3" 1 1/2" 3/4" 3/4" PROVIDE W/ MR -371 FAUCET, HOSE, HOSE BRACKET, MOP HANGER, MR -375 STRAINER, & MR -374 LOK SEAL. HOSE ATTACHEMENT ON FAUCET SHALL BE EQUIPPED WITH AN ANTI - SIPHON VACUUM BREAKER. NOTE: DUNHAM Dunham Associates, Inc. 50 South Sixth Street / Suite 1100 Minneapolis, Minnesota 55402 -1540 PHONE 612.465.7550 FAX 612.465.7551 WEB dunhameng.com mechanical + electrical consulting engineering MBA Architects, Inc. 3823 Creekside Lane Holmen, WI 54636 608 - 785 -2760 FAX:608- 785 -2750 http://www.mba-architects.com PROJECT NAME: FRANCESCA'S COLLECTIONS PROJECT ADDRESS: SOUTH CENTER MALL TUKWILA, WA CLIENT NAME: FRANCESCA'S COLLECTIONS i as c 0 L L E ,° T I O N S PROJECT MANAGER: DATE CLIENT 1 LANDLORD CONTRACTOR I IVENDOR REVISION 1 COMMENTS 6/29/10 X X MALL REVIEW 7/7/10 X X FINAL REVIEW 7/14/10 X X X PERMIT 14/m at TB 1 Checked By: GS THIS SHEET CONTAINS: MECHANICAL AND PLUMBING SPECIFICAITON 0411995 -012 M2