Loading...
HomeMy WebLinkAboutPermit PG10-131 - MUSEUM OF FLIGHT - SPACE SHUTTLE GALLERYMUSEUM OF FLIGHT SPACE SHUTTLE GALLERY 9305 EAST MARGINAL WYS EXPIRED 04 -12 -11 PG1O-131 Parcel No.: Address: Project Name: City ukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.ci.tukwila.wa.us PLUMBING /GAS PIPING PERMIT 5624201034 9305 EAST MARGINAL WY S TUKW MUSEUM OF FLIGHT SPACE SHUTTLE GALLERY Permit Number: Issue Date: Permit Expires On: PG10 -131 10/14/2010 04/12/2011 Owner: . Name: Address: Contact Person: Name: Address: Email: KING CO MUSEUM OF FLIGHT 9404 E MARGINAL WAYS , SEATTLE WA 98108 MICHAEL HARSHMAN 11611 49 PL W , MUKILTEO WA 98275 MHASHMAN@UMCI.COM Contractor: Name: UNIV MECHANCL CONTRS INC Address: 11611 49TH PL W , MUIULTEO WA 98275 -4255 Contractor License No: UNIVMC *343N9 Phone: 206 368 -6971 Phone: 206 - 364 -9900 Expiration Date: 10/03/2012 DESCRIPTION OF WORK: RAIN WATER LEADER PIPING AND OVERFLOW RAINWATER PIPING WITH (3) ROOF DRAINS. NATURAL GAS PIPING WITH ONE OUTLET. Value of Plumbing /Gas Piping: Fees Collected: $53,098.00 $249.38 Permit Center Authorized Signature: Uniform Plumbing Code Edition: 2009 International Fuel Gas Code Edition: 2009 Date: CQ Vv1 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work I am authorized to sign and obtain this plumbing /gas piping permit Signature: e(r) Date: 10I5`Y/0 Print Name: W e272-c This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: UPC -4/10 PG10 -131 Printed: 10 -14 -2010 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 -431 -3665 Web site: http. / /www.ci.tukwila.wa.us Parcel No.: 5624201034 Address: Suite No: Tenant: PERMIT CONDITIONS 9305 EAST MARGINAL WY S TUKW MUSEUM OF FLIGHT SPACE SHUTTLE GALLERY Permit Number: Status: Applied Date: Issue Date: PG10 -131 ISSUED 09/21/2010 10/14/2010 1: ** *PLUMBING AND GAS PIPING * ** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R -3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor /ceiling assemblies and fire - resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. * *continued on next page ** doc: Cond -10/06 PG10 -131 Printed: 10 -14 -2010 • J�.`N��4 wq� City of Tukwila n Q � ,� O 2908 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Signature: �c- Print Name: LC-7 l . &z..ek Date: la /14 ordinances governing or local laws regulating doc: Cond -10/06 PG10 -131 Printed: 10 -14 -2010 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.citukwila.wa.us Plumbing/Gas Permit No. koroffie a use only) PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** S TE LOCATION c-A7Ati6- 4 King Co Assessor's Tax No.: `-�.4 �, 2 ' I (� Suite Number: New Tenant: Site Address: R/ L5 Em-sr Mr 1,7, 0 (VFW Tenant Name: %Yl u Seta., o 1- F/1 I+ Property Owners Name: ('\uselt ri, U t7 T Floor: ❑ Yes D..No Mailing Address: Cryotr E s i' MA rq ► h 4 I (/i%■4y S Se4 fH-e City State 9g/CE- Zip CONTACT PERSON Who do we contact when your permit is ready to be issued Name: l/MCI,Nti .( 14-arsLrytCt, Mailing Address: 11(o L f 1 E -Mail Address: Y1� 1,tetY (An-Cis , con"- Day Telephone: al t,t e l Leo City o(0- 36 G471 (�c119 9275 State Zip Fax Number: 2 0 1 --- 3 6 5 -- / SOU PLUMBING / GAS PIPING CONTRACTOR INFORMATION Company Name: RL°Gh44,6-4. II (� Mailing Address. • (el ( h/ PL . G ) W. Contact Person: /11 t hkp I f gar-. E -Mail Address: rc h m a vt tfmCI. cove, Contractor Registration Number: CO v∎4 -4 c TD i'S 's"''C. AA He° con- 9F2-7 S City Day Telephone: State Zip 2a(D -36g — G97/ Fax Number: 2 0 (0--- Expiration Date: ARCHITECT OFRECORD° -All plans must be stamped by Architect of Record Company Name: SRG Poic- Avercklp Mailing Address: / I 0 Up, /;,,, 54 Contact Person: G744 h /i'(essirey E -Mail Address: hMessmer sr5 pet r -111,8 r-511iP.Coy -. City Day Telephone: 266 -- 9 7 3 —/ G 45-- Fax Number: State Zip ENGINEER OF RECORD -All plans must be stamped by Engineer of Record Company Name: ani(!t°rsr ineCAah /Ga / Co n'I-raC Mailing Address: 1 1(01 I y 11 PL. W. Contact Person: DG v ► c) fl a to y, t Mail Address: d6latiorie 0 (4m/ cor► -•- M lie-a WPr 95275 City State Zip Day Telephone: 206_3i_ 990e) Fax Number: ms\Forms- Applications On Line\2010 Applications \7 -2010 - Plumbing -Gas Piping Permit Application.doc 10 Page i of 2 New BOG. Valuation of Project (contractor's bid prig ,. $ 5 3, 01$ Scope of Work (please provide detailed information): Barr. p j 1/7/4/G %va�s✓ /ead Pr /nit -ti 73t w4Gr C3) goo-t drettn 5 N/ jrA l G'tis Building Use (per Int'l Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: Sewer: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) Food -waste grinder, commercial Floor Drain Shower, single head trap Lavatory Wash fountain Receptor, indirect waste Sinks Urinals Water Closet Building sewer and each trailer park sewer Rain water system — per drain (inside building) Water heater and/or vent Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity) Grease interceptor for commercial kitchen ( >750 gallon capacity) Repair or alteration of .water piping and/or water treatment equipment Repair or alteration of drainage or vent piping Medical gas piping system serving 1 -5 inlets/outlets for a specific gas Each additional medical gas inlets /outlets greater than 5 Backflow protective device other than atmospheric -type vacuum breakers 2 inch (51 mm) diameter or smaller I Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Each lawn sprinkler system on any one meter including backflow protection devices Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1 -5) Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Gas piping outlets I PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER ER OR/�AUTHORIZED AGENT: Signature: klic Print Name: m► G h 4 e, / !/ fr.4,774,'` Mailing Address: f J (o / / t{ q f k- PL W Date Application Accepted: 0112-t1 o Date Application Expires: Date: 9, 2oi Day Telephone: 20 Cv -3647- 97 Ai lei /4v 982 7,,— City State Zip 0;17-1 I c � ations\Forms - Applications On Line \2010 Applications \7-2010 - Plumbing -Gas Piping Permit Application.doc 2010 Staff Initials: Page 2 of 2 'ty of Tukwila 1028701 -1 i 20 10/14/2010 001 101 DCD Permi 'lus - General Fund MUSEUM OF FLIGHT SPACE SHUTTL $199.50 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: //www. ci. tukwila. wa. us `Parcel No 5624201034 Address: Suite No: 9305 EAST MARGINAL WY S TUKW RECEIPT Applicant: MUSEUM OF FLIGHT SPACE SHUTTLE GALLERY Permit Number: PG10 -131 Status: APPROVED Applied Date: 09/21/2010 Issue Date: Receipt No.: R10 -02077 Payment Amount: $199.50 Initials: WER Payment Date: 10/14/2010 02:16 PM User ID: 1655 Balance: $0.00 Payee: LESTER BOUCK TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd MC Authorization No. ACCOUNT ITEM LIST: Description 199.50 Account Code Current Pmts GAS - NONRES PLUMBING - NONRES 000.322.103.00.00 96.60 000.322.103.00.00 102.90 Total: $199.50 doc: Receiot -06 Printed: 10 -14 -2010 Cillbof Tukwila. • Department of Community Development 6300 Southcenter Boule_vard,.S.uite_ #100_ _ Tukwila, Washington 98188= _ == - _ Phone: 206 -431 -3670 Fax: 206-431-3665 Web site: http: //www. ci. tukwila. wa. us SET RECEIPT RECEIPT NO: R10 -01872 Initials: JEM Payment Date: 09/21/2010 User ID: 1165 Total Payment: 1,551.23 Payee: LESTER W BOUCK SET ID: S000001422 SET NAME: Tmp set/Initialized Activities SET TRANSACTIONS: Set Member Amount M10 -127 M10 -128 PG10 -131 PG10 -132 TOTAL: 624.71 729.11 49.88 147.53 624.71 TRANSACTION LIST: Type Method Description Amount Payment Credit C MC 1,551.23 TOTAL: 1, 551.23 ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 1,551.23 TOTAL: 1, 551.23 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 F (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 P640- /a /. Project: i' /2/Q 2'm or /7/W7-- Type of Inspection: Address: ^3®' Date Called: r Special Instructions: Date Wanted: 7,- 4 — / a.m. p.m. Requester: Phone No: I Approved per applicable codes. Corrections required prior to approval. COMMENTS: a) AP-4,/e. - MA / ) 2 4%Z6- 07 Ally A Pa, 5.11 - •&.i — 4 AS — 410 7A/e, r ,......\ 4\ 1 Spector bE NSPECTION FEE RE(JIRED. Prior to next inspection. fee must be ud at 6300 SouthcenterBlvd., Suite 100. Call to schedule reinspection. 03 -02 -2011 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director MICHAEL HARSHMAN 1161149PLW MUKILTEO WA 98275 RE: Permit No. PG10 -131 9305 EAST MARGINAL WY S TUKW Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and /or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 04/12/2011. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period, , provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and /or receive an extension prior to 04/12/2011, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, c Bill Rambo Permit Technician File: Permit File No. PG10 -131 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 •PE1T C 1D COPY • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: PG10 -131 DATE: 09/21/10 PROJECT NAME: MUSEUM OF FLIGHT SPACE SHUTTLE GALLERY SITE ADDRESS: 9305 EAST MARGINAL WY S X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: ing i\-1° Buid Ivision Works ITC Wo Fire Prevention Structural Planning Division Permit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete IXt Comments: Incomplete ❑ DUE DATE: 09/23/10 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Building Please Route ix Structural Review Required u No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 10/21/10 Not Approved (attach comments) n DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 Contractors or Tradespeople Peter Friendly Page • General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name UNIV MECHANCL CONTRS INC UBI No. 578025176 Phone 2063649900 Status Active Address 11611 49Th Pl W License No. UNIVMC *343N9 Suite /Apt. License Type Construction Contractor City Mukilteo Effective Date 8/29/1966 State WA Expiration Date 10/3/2012 Zip 982754255 Suspend Date County Snohomish Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status GRANSML982R3 GRANSTON MECHANICAL LLC Construction Contractor General Unused 12/23/2002 1/8/2009 Expired Business Owner Information Name Role Effective Date Expiration Date BUSH, GERALD D President 03/13/2002 Bond Amount GRANSTON, EDWARD B Secretary 03/13/2002 08965196 PETTERSON, DEAN M Treasurer 03/13/2002 SMITH, DOUG Vice President 03/18/2002 TRAVELERS CAS & SURETY CO KOMMERS, EDWARD D Vice President 03/13/2002 09/13/2004 BALDWIN, TERRY L Vice President 03/13/2002 09/10/2003 GRANSTON, FRANK Treasurer 03/18/2002 12/23/2002 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 7 FIDELITY &DEPOSIT CO OF MD 08965196 07/31/2009 Until Cancelled $12,000.0006/04 /2009 6 TRAVELERS CAS & SURETY CO 103335164 07/22/2001 Until Cancelled 07/31/2009 $12,000.00 10/03/2001 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 30 THE PHOENIX INS CO C0526D8270PHX10 10/01/2010 10/01/2011 $1,000,000.00 09/22/2010 29 PHOENIX INS CO C0526D8270PHX09 10/01/2009 10/01/2010 $1,000,000.00 09/22/2009 28 TRAVELERS PROPERTY CAS INS CO DTE0526D8270TIL07 10/01/2007 10/01/2009 $1,000,000.0009 /19/2008 27 TRAVELERS PROPERTY CAS INS CO DTEC0526D8270TIK07 10/01 /2007 10/01/2008 $250,000.00 09/21/2007 26 TRAVELERS INDEMNITY CO DTC0526D8270IND05 10/01/2006 10/01/2007 $1,000,000.00 09/19/2006 25 ST PAUL FIRE & MARINE INS CO KC08400101 10/01/2004 10/01/2006 $1,000,000.00 09/21/2005 https://fortress.wa.gov/lni/bbip/Print.aspx 10/14/2010 GENERAL SYMBOL OP XX' -XX° (,(L XX' -XX° ) — Et L - « -* SP * -* (E XX' —XX° F- 0 —4-- xxxxxxxxx XXXX (;fOP XX' —XX" --1I1— O-- ABBR DESCRIPTION 45 45 DOWN 90 AD ACCESS DOOR IN CEILING ACCESS DOOR IN WALL ALIGNMENT GUIDE ANCHOR AUTOMATIC CONTOL VALVE (3 -WAY) AUTOMATIC CONTROL VALVE (2 -WAY) BALANCING VALVE BV BALL VALVE BOP BOTTOM OF PIPE ELEVATION BREAK BFV BUTTERFLY VALVE CAP CENTERLINE CL -EL CENTERLINE OF PIPE ELEVATION CHK. CHECK VALVE CIRCUIT SETTER DETAIL TAG DN DOWN ELEVATION TAG FLOW ARROW GAS COCK GLOBE VALVE GV GATE VALVE IE INVERT PIPE ELEVATION PITCH LEFT PITCH RIGHT PLUG POC POINT OF CONNECTION PG PRESSURE GAUGE PRV . PRESSURE REDUCING VALVE ROLLING 45 DOWN REDUCER REDUCING CONCENTRIC REDUCING ECCENTRIC RV RELIEF VALVE . . SHEET NOTE DESIGNATION SLEEVE SV SOLENOID VALVE TEE DOWN TEE TH THERMOMETER LONG TAG 9 CHARCTERS MAX MEDIUM TAG 6 CHARCTERS MAX SHORT TAG 4 CHARCTERS MAX TOP TOP OF PIPE ELEVATION 11 UNION UP PLUMBING SYMBOL •. —A- -CD— I I i - --KTI— �t I I II— —D— —{ DCBP I- -- DET— O 0 —GRW- —140— — 140- - IR— —1W - f. —NPCW— — ORL - -PC- -PW— —1 RPBP (--- —RWL- -RWL- -SD- -SS- --T— TP — —TR — ilL ABBR DESCRIPTION VERTICAL SLEEVE VALVE IN PIPE RISE OR DROP STR WYE TYPE STRAINER A COMPRESSED AIR CD CONDENSATE DRAIN DOUBLE COMBO COMBO LEFT COMBO LEFT W/ 1/4 BEND COMBO LEFT W/ 1/8 BEND COMBO RIGHT COMBO RIGHT W/ 1/4 BEND COMBO RIGHT W/ 1/8 BEND CO CLEANOUT CW DOMESTIC COLD WATER D INDIRECT DRAIN LINE DCBP DOUBLE CHECK BACKFLOW PREVENTER DET DETERGENT DRAIN FCO FLOOR CLEANOUT GRW GREASE WASTE GW• GARAGE WASTE HB HOSE BIBB HOSE END DRAIN VALVE HW DOMESTIC 120' F HOT WATER HW DOMESTIC 140' F HOT WATER HWC DOMESTIC 120' F HOT WATER CIRCULATION HWC DOMESTIC 140' F HOT WATER CIRCULATION IR IRRIGATION LINE IW INDIRECT WASTE LONG RADIUS 90 NPCW NON- POTABLE COLD WATER OD OVERFLOW ROOF DRAIN ORL OVERFLOW RAIN WATER LEADER PC PW RD RPBP RWL P -TRAP PUMPED CONDENSATE PUMPED WASTE ROOF DRAIN REDUCED PRESSURE BACKFLOW PREVENTER: RAIN WATER LEADER, ABOVE GROUND RWL RAIN WATER LEADER, UNDERGROUND SD STORM DRAIN SS SANITARY SEWER T TEMPERED WATER TP TRAP PRIMER TR TEMPERED WATER RETURN V VENT VTR VENT THRU ROOF PIPING SYMBOL ABBR DESCRIPTION — W — W WASTE —W W WASTE UNDERGROUND HY WALL HYDRANT WHA WATER HAMMER ARRESTER ICI II I MV —BFW- WYE LEFT WYE RIGHT AUTOMATIC AIR VENT BFW BOILER FEED WATER BUCKET TRAP CONTROL AIR CHILLED WATER RETURN CHILLED WATER SUPPLY CONDENSER WATER RETURN CONDENSER WATER SUPPLY FLANGE FLEX FLOAT AND THERMOSTATIC FOR FUEL OIL RETURN FOS FUEL OIL SUPPLY FOV FUEL OIL VENT G NATURAL GAS GLR GLYCOL RETURN GLS GLYCOL SUPPLY HCR HIGH PRESSURE CONDENSATE RETURN HG HOT GAS HPS HIGH PRESSURE STEAM HWR HEATING HOT WATER RETURN HWS HEATING HOT WATER SUPPLY LCR LOW PRESSURE CONDENSATE RETURN LPS LOW PRESSURE STEAM . MAV MANUAL AIR VENT MCR MEDIUM PRESSURE CONDENSATE RETURN METER MG MEDIUM PRESSURE NATURAL GAS MPS. MEDIUM PRESSURE. STEAM PCR PUMPED CONDENSATE RETURN PI PRESSURE INDICATOR RL REFER LIQUID RS REFER SUCTION TEMPERATURE PRESSURE TEST PLUG TI TEMPERATURE INDICATOR TS TEMPERATURE SENSOR VB VACUUM BREAKER VENTURI -CA— CA — CHR— CHR — CHS— CHS — CR CR - --CS— CS —FOR- - FOS — — FOV - - G— — GLR — GLS — .NCR — HG- -HPS— - HWR— - HWS— — LCR — LPS — • —NCR- -MG— • — MPS- — PCR- —RL— —RS —. T ABBREVIATIONS AD AFF CB CP DF EWC FD FS NIC NTS REV RFI UNO ACCESS DOOR, AREA DRAIN ABOVE FINISHED FLOOR CATCH BASIN CHANGE PROPOSAL DRINKING. FOUNTAIN ELECTRIC WATER COOLER FLOOR DRAIN FLOOR SINK NOT IN CONTRACT NOT TO SCALE REVISION REQUEST FOR INFORMATION UNLESS NOTED OTHERWISE GENERAL NOTES 1. BOP = BOTTOM OF PIPE OR BOTTOM OF INSULATION ON INSULATED ONES (SEE INSULATION MATRIX FOR PIPING SYSTEMS THAT REQUIRE INSULATION.) 2. TOP = TOP OF PIPE OR TOP OF INSULATION ON INSULATED LINES (SEE INSULATION MATRIX FOR PIPING SYSTEMS THAT REQUIRE INSULATION:) 3. ALL ELEVATIONS ARE. REFERENCED FROM FINISHED FLOOR. UNLESS OTHERWISE NOTED. 4. • = PIPE SLEEVE REQUIRED UP THRU SLAB ABOVE AT THIS LOCATION. 5. = DRAIN BODY REQUIRED AT THIS LOCATION. 6. WHERE WATER PIPING MUST RUN IN EXTERIOR WALL. INSTALL ALL SUCH PIPING ON THE WARM SIDE (INTERIOR) OF ALL BUILDING INSULATION. 7. GRADED PIPE IS TO BE 1/4" PER FOOT. ON ALL WASTE LINES UNO AND 1/8" PER FOOT ON ALL RAINWATER PIPING UNO. 8. ALL COORDINATION CONFLICTS SHOULD BE REVIEWED PRIOR TO MAKING ADJUSTMENTS TO PIPING SYSTEMS WITHOUT PROPER TRACKING REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. PLUMBING INDEX OF DRAWINGS PLUMBING DRAWING INDEX SHEET f DE8CMPlION P001 PLUMBING SYMBOLS AND ABBREVIATIONS P100 PLUMBING SCHEDULES P102 PLUMBING SCHEDULES P200 UNDERGROUND PLUMBING PLAN P201 LEVEL ONE PLUMBING PLAN P202 LEVEL TWO PLUMBING PLAN P203 • ROOF PLUMBING PLAN P300 PLUMBING DETAILS SCALE N/A NA. 1/8 " =1' -0' 1/8° =1' -0• 1/8 " =1' -0' NA SEPARATE PERMIT REQUIRED FOR: of Mechanical Giectrical 0 Plumbing ❑ Gas Piping City of Tukwila BUILDING DIVISION FILE COPY Permit No. P41°°m (31 Plan review approval is subject to errors and omissions. L p rroval of construction documents does not authorize f e violation of any adopted code or ordinance. Receipt of approved Field Copy and conditions is acknowledged: By efe Date: 1a City Of Tukwila BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE APoonifFID OCT 01 201d A-8- �" ) i / of Tukwila BUILDINw nnagIllN crrROMILA SFP 21 2010 PERMIT CENTER polo -131 Museum of Flight Commercial T.I. Permit 9404 East Marginal Way South, Seattle, WA Commercial T.I. Permit Drawing Title DRAWING INDEX Revisions No. Description Date. Drawn by UMC Checked by DM Date August 18, 2010 Project No 210022 Consultant Project No Owner Project No Drawing No P001 PLUMBING FIXTURE SCHEDULE EQUP. ID NO SERVICE / LOCATION MANUFACTURER MODEL TRIM ROUGH —IN NOTES FLUSH VALVE FAUCET SHOWER VALVE DRAIN MISC CW HW W V EWC -1 DUAL HT WATER COOLER -- ADA ELKAY . ' INPUT TAM (MN, & MAX) N/A N/A INTEGRAL 8.0 GPH, 50 DEG. WATER, 120 V, 1- PH, 4.6 FLA 1 2 -- 1 -1/4" 2' ADA COMPLIANT FCO FLOOR CLEANOUT ZURN 1400 N/A N/A N/A N/A -- -- SEE PLAN -- SEE NOTE NO 1 L -1 COUNTERTOP MOUNTED LAVATORY '.. KOHLER CAXTON K -2210 N/A SLOAN EAF -275 MCGUIRE 155A 1 -1/4' X 1 -1/2" 17 GA P -TRAP 1/2' 1/2' 1 -1/2" 2' SEE NOTE NO 3 L -2 COUNTERTOP MOUNTED LAVATORY ADA KOHLER CAXTON K -2210 N/A SLOAN EAF -275 MCGUIRE 155WC 1 -1/4' X 1 -1/2" 17, GA P —TRAP 1/2" 1/2• 1-1/2" •, 2' SEE NOTE NO. 4 MS -1 MOP SINK FIAT MSB -2424 N/A FIAT 830—M FIAT 1453 —BB N/A 3/4' 3/4' 3' 2" SEE NOTE NO. 5 U -1 URINAL ZURN Z5738 ZEG6003EV -HW6 N/A N/A N/A 3/4' - - 2• 2' SEE NOTE NO. 6 U -2 URINAL ADA ZURN Z5738 ZEG6003EV —HW6 N/A N/A N/A N/A N/A BEMIS 1955C 3/4" 1' -- -- 2• 3" 2" 2" SEE NOTE NO 7 SEE NOTE NO 8 WC -1 WATER CLOSET (WALL MOUNTED) KOHLER K -4330 SLOAN WES -111 WC -2 WATER CLOSET (WALL MOUNTED) — ADA KOHLER K -4430 SLOAN WES -111 N/A N/A BEMIS 1955C 1' -- 3" 2" SEE NOTE NO 9 WHA WATER HAMMER ARRESTER WILKENS 1250 N/A N/A N/A N/A -- -- -- -- -- NOTES: • • ALL FIXTURES LISTED AS "ADA COMPLIANT" MUST CONFORM TO WAC • 5140 REQUIREMENTS FOR ACCESS 1 ADJUSTABLE FLOOR CLEANOUT, GAS TIGHT, ABS TAPERED THREAD PLUG,TOP ADJUSTABLE TO FINISH FLOOR 2•LOCKABLE RECESSED BOX, HOSE THREADED SPOUT, LOOSE KEY HANDLE AND VACUUM BREAKER 3 OCR19C i/2' X' 3/8" ANGLE . STOP, B1F20 FLUIDMASTER 3/8C X 1/2 IP 20 SS, .5 GPM FLOW . 4 OCR19C 1/2• X 3/8• ANGLE STOP,.B1F20 FLUIDMASTER 3/8C X 1/2 IP 20 SS, TRUEBRO TRAP WRAP. FOR NW SUPPLY AND P —TRAP, MOUNT ADA COMPLIANT, .5 GPM FLOW 5 FURNISH WITH FIAT HOSE / BRACKET ASSY • #832—M AND FIAT #889 —CC MOP HANGER 6 FURNISH WITH ZURN Z -1221 CARRIER OR STEEL PLATE,. 7 FURNISH WITH ZURN Z -1221 CARRIER: OR STEEL PLATE, ADA MOUNTING HEIGHT. 8 FURNISH WITH SEAT LESS COVER, ZURN Z -1203 SERIES, GAL / FLUSH 1.6 AND 1.1 9 FURNISH WITH SEAT LESS COVER, ZURN Z -1203 SERIES, GAL / FLUSH 1.6 AND 1.1, MOUNT TO BE ADA COMPLIANT 10 PROVIDE DELTA RPW111HDF HANDHELD SHOWER SPRAY WITH SUDE BAR, VACUUM BREAKER, 1/2" WALL SUPPLY ELBOW, 60" BRAIDED HOSE, ADA COMPLIANT, 2.5 GPM 11 PROVIDE BRICOR SP— BB15OCHE 1.5 GPM SHOWERHEAD, PRESSURE AT 75 -80 PSI GAS- IRED COMMERCIAL WATER HEATER SCHEDULE TAG GM -1 SERVICE • 904 BLDG LOCATION LEVEL 1 JANITORS CLOSET STRAINER SIZE STRAINER DUN EQUIPMENT NOTES MANUFACTURER MINA MOOFL RC98NPI 2' NI BR PERFORMANCE LIGHT . ' INPUT TAM (MN, & MAX) 9.5 - 199 EFFldENCY . 97%' HOT WATER CAPACfY .4 / 9.8 GPM EWT (DEG F) 50 Lwr (DEG F) 120 SIZE ON) FULL LOAD AMPS (RA) ELECTRICAL OVERFLOW ROOF DRAIN VOLT /PHASE . 120/1 • : . ELECTRICAL CONSUMPTION NORMAL - 80 WATTS / STAND BY - 2 WATTS 151DIA LIGHT PHYSICAL 2 . GAS CONN. SIZE 3/4 FLUE SIZE 8" • COMB AIR SIZE • 6" WOGHi 75 LBS. 3 9 ACCESSORIES • FLOW SWITCH . YES FACTORY-WIRED CONTROL PANEL YES NATURAL GAS METER SCHEDULE TAG GM -1 SERVICE 904 BLDG & SHUTTLE GALLERY LOCATOR S. MM. 904 BLDG. STRAINER SIZE STRAINER DUN EQUIPMENT NOTES MANUFACIURER GENERAL / SEE PLANS MODEL Z- 415 —B —P 2' NI BR PERFORMANCE LIGHT CAPACTLY (CFH) 2200 CFH INLET PRESSURE 2P51 PRESSURE DROP VOLTS /PHASE 120 / 1 POWER PHYSICAL . MIN. CIRC. AMPACITY (MCA) SIZE ON) FULL LOAD AMPS (RA) ORD -1 OVERFLOW ROOF DRAIN ACCESSORIES Z- 100— C —R -89 • PULSE INTERFACE TO READ 1316 POLY 151DIA LIGHT NO —HUB NOTES: $c.?e OF Work PLUMBING DRAIN SCHEDULE EQUIP. ID NO. • SERVICE / LOCATION MANUFACTURER MODEL OUTLET SIZE STRAINER MATERIAL STRAINER SIZE STRAINER DUN OUTLET TYPE NOTES FD -1 GENERAL / SEE PLANS ZURN Z- 415 —B —P 2' NI BR 5" DIA LIGHT NO —HUB 1 HP 39 WATTS . ELECTRICAL DATA VOLTS /PHASE 120 / 1 POWER NORMAL MIN. CIRC. AMPACITY (MCA) -- FULL LOAD AMPS (RA) ORD -1 OVERFLOW ROOF DRAIN ZURN Z- 100— C —R -89 • SEE PLAN . POLY 151DIA LIGHT NO —HUB 2 RD -1 ROOF DRAIN ZURN Z- 100 —C —R SEE PLAN • POLY _ 15 "DIA UGHT NO —HUB 3 1. COATED CAST —IRON BODY WITH BOTTOM OUTLET, INVERTIBLE MEMBRANE CLAMP, ADJUSTABLE COLLAR, TRAP PRIMER CONNECTION 2. SAME AS NOTE 5, WITH 2" EXTERNAL WATER DAM. 3. COMBINATION MEMBRANE FLASHING CLAMP /GRAVEL GUARD AND LOW SILHOUETTE POLY — DOME, UNDERDECK CLAMP, EXTENSION AND ROOF SUMP RECEIVER HOT WATER RECIRCULATION PUMP SCHEDULE TAG CP -1 LOCATION JANITORS CLOSET 904 BLDG. SERVICE DOM. HOT WATER MANUFACTURER B & G MODEL NO. CIRCULATORS NBF -8S /LW PUMP 64 FLOW RATE (GPM} 1 HEAD (FT) 7 RPM 2800 BHP -- HP 39 WATTS . ELECTRICAL DATA VOLTS /PHASE 120 / 1 POWER NORMAL MIN. CIRC. AMPACITY (MCA) -- FULL LOAD AMPS (RA) 0.38 STARTER RELAY FURNISHED /INSTALLED EC. / EC DISCONNECT BY ELECT. FURNISHED /INSTALLED EC / EC PHYSICAL DATA LENGTH (IN) 5 -3/8" WIDTH (IN) 4 -7/8" HEIGHT (IN) 5 -5/8" FLANGE SIZE NPT (IN) OR SWEAT 1/2" SWEAT OPERATING WEIGHT (LBS) 9 NOTES 1,2 filename: dhwpump.x2a NOTES: 1. BRONZE FITTED DOMESTIC HOT WATER CIRCULATOR 2. PROVIDE AQUASTAT B & G MODEL AQ -1/2 OR B & G MODEL AQ -3/4" (120V / 1 PH) REDUCED PRESSURE BACKFL OW PREVENTER SCHEDULE EQUIP. ID NO. SERVICE / LOCATION AND MODEL MANUFACTURER MODEL FLOW (GPM) PRESSURE DROP (PSI) NOTES RPBP -1 2' DOM CW TO BUILDING / WATER ENTRY RN LEVEL 1 2" WILKENS PRV- -1 . 64 WILKENS 1 1. FURNISH WITH AIRGAP FITTING, INTEGRAL STRAINER, ISOLATION VALVES. DOMESTIC WATER PRESSURE REDUCING VALVE SCHEDULE EQUIP. ID NO SERVICE / LOCATION MANUFACTURER MODEL SIZE FLOW (GPM) , INLET PSI OUTLET PSI FALL OFF PSI • NOTES PRV- -1 . DOMESTIC WATER HEADER / WATER ENTRY RM LEVEL I WILKENS ZW109 2" 64 126 80 NOTE 2 NOTE 1 & 3 1. DOMESTIC WATER PRESSURE REGULATOR WITH GAUGE TAPPING 2. NO FALL OFF PRESSURE, CONSTANT PRESSURE SET AT 80 PSI DOWNSTREAM 3. PRESSURE REDUCING VALVE LOCATED ON DOMESTIC WATER BY —PASS UNE AT WATER HEADER GAS PRESSURE REGULATOR SCHEDULE TAG PRV -1 SERVICE RN -1 / GWH -1 LOCATION 904 BLDG. ROOF EQUIPMENT MANUFACTURER MODEL PERFORMANCE CAPACITY (CFH) 2200 INLET (PSG) 2 OUTLET (IN WG) 7 -11' WC PHYSICAL ORIFICE SIZE PIPE SIZE NOTES: PG ( 0 X31 PREVIEWED FOR CODE COMPLIANCE OCT 0 1 2H„1 City of Tukwila BUILDINw MARION CARAILA SEP 21 2010 PERMIT CENTER cu m w a) 4•• se cit) :— V) tit a) III 2 Commercial T.I. Permit Commercial T.I. Permit Drawing Title PLUMBING SCHEDULES Revisions No. Description Date Drawn by UMC Checked by DM Date August 18, 2010 Project No 210022 Consultant Project No Owner Project No Drawing No P100 NATURAL GAS ABOVE GROUND (231123) fl LIB 2' + SMALLER 2-1/2• + L1F6>ER PIPE MATERIALS ST. WE C.I. NO —HUB PIPE MATERIALS ASTM A53, S40 BLACK (GALV. ON EXTERIOR) ASTM A53, STD WT, BLACK (GALV. ON EXTERIOR) JOINT TYPE THREADED do COUPLED WELDED FRITNG MATERIAL ASME B16.3 GALVANIZED, 1501 ASME B16.3 BLACK OR GALVANIZED, 1501 RANGES N/A FORGED STEEL 154 GASKETS N/A ASME B16.21, 1/6" NON— ASBESTOS BOLT TYPE _N/A A307 GRADE B PLATED — Responsible (City, Owner, Owner Rep., etc ?) TEBT/t4BPECIION UMC WELD PROCEDURE HNC WELD INSPECTION (Visual. X —ray. etc ?) 8. 1 , INSPECTION AIt MR — Media (Air, Water. Aaron, Nitrogen. etc ?) — Duration a HOURS 8 HOURS — Pressure (psi or ft. • head) 100 PSG 100 PSG — Responsible (City. Owner, • Owner Rep., etc ?) OWNER RE' / UWYIIY / COY OWNER REP 1 WIRY nY / WY 5/8" 3/4" NOTES: 1) INSULATE ROOF DRAIN BODIES AND PIPING. VALVES GAS COCK: THD NIBCO T- 585 -70 -UL N/A GAS COCK: FIG N/A NORDSTROM 143 SEISMIC SHUTOFF. PACIFIC SEISMIC 300 SERIES N/A SPECIALTY VALVEB FUEL GAS CONNECTORS DORMONT 10 SERIES FUEL GAS APPLIANCE VALVES N/A N/A SEISMIC SAFETY SHUTOFF N/A _N/A Y- PATTERN, 2501 < 3 N/A N/A Y— PATTERN, 1251 > 2 N/A N/A PPE WES —) 1/2 3/4 1 11/4 11/2 2 21/2 S 4 6 8 10 HANGERS Ru>loutthr' INSULATION THICKNESS NONE NONE NONE NONE NONE NONE NONE NONE NONE NONE NONE NONE NONE HANGER LOOP LOOP LOOP • LOOP LOOP LOOP CLEVIS CLEVIS CLEVIS CLEVIS • CLEVIS • CLEVIS HANGER ROD SIZE 3/8 3/8 3/8 3/8 3/8 3/8 3/8 1/2 1/2 5/8 7/8 7/8 MAXIMUM HANGER SPACING ' 6' 8' 8' 8' 8'. 10' 10' 10' 10' 10' 10' 10' NOTES: RAIN LEADER ABOVE GROUND (221316) rlEdB 2112' + LARGER PIPE MATERIALS ST. WE C.I. NO —HUB JOINT TYPE CISPI 301, AS I( C564 NO —HUB FITTING MATERIAL ST. WF. C.I. NO —HUB RUING COUPLINGS HEAVY DUTY TEffr/INSPECDON INSPECTION — Media (Air, Water, Agron, Nitrogen. etc ?) WATER — Duration 4 HOURS — Pressure (psi or ft. head) IO FEET OF HEAD — Responsible (City, Owner, Owner Rep., etc ?) OWNERS REP. AND MJ1HORRY HAYING JURISDICTION HNC 6' 8. 1 , HANGER CLEVIS CLEVIS CLEVIS INSULATION 1' — CAL SIL 1" — CAL SIL 1" — CAL SIL HANGER ROD SIZE 5/8" 5/8" 3/4" NOTES: 1) INSULATE ROOF DRAIN BODIES AND PIPING. RAIN LEADER BELOW GROUND (22 1316) ITBiA6 2 1/r + LAROSE PIPE MATERIALS ST. K. C.I. NO —HUB JOINT TYPE CISPI 301, ASTM C564 NO -HUB FITTING MATERIAL ST. WT. C.I. NO —HUB FITTING COUPLINGS HEAVY DUN TEBT/SEPEC110N INSPECTION — Media (Air. Water, Agron. Nitrogen. etc ?) WATER — Duration 4 HOURS — Pressure (psi or ft. head) 10 FEET OF HEAD — Responsible (City, Owner, Owner Rep., etc ?) OWNER REP AND AUTHORITY HAVING JURISDICTION Secs P� OF to1i0iZk 1)(9 l 0- I 31 bVILVVIL (UM CODE COMPLIANCE OCT 0 1 2'ii0 City of Tukwila BUILDING DIVISION cnARSILA SEP 212ota PEiMITCENTER We Build Value f„ = a� (/) g ta4 CL Commercial T.1. Permit 9404 East Marginal Way South, Seattle, WA Commercial T.I. Permit Drawing Title PLUMBING SCHEDULES Revisions No. • Description Date Drawn by UMC Checked by DM Date August 18, 2010 Project No 210022 Consultant Project No Owner Project No Drawing No (eF ( eG eG7 /-._ ~\ eK i _ _- e3 ! e2 el ( A.2 { A.51 1r A.8 P.O.C. 12 "RWL, SEE CIVIL DWG BEYOND 5' -0" OUTSIDE BLDG FOR CONTINUATION I.E: 11.18' 4 "e SD UP 4'eW UP TO WC 2 "3VU'. 4 "e W UP TO WC. 4 "e W • UP TO WC 2 "e W TO FD t 4 "e W TOFCO .` 3 "e W UP TO URINALS 2 "eWTOF 3 "e W UP TOLAV 4 "e (E) SS TO REMAIN 4 "e (E) SS C C.O. 3 "eW UP TO MS 2 "e W UP TO LAYS 4 "e W (E) 6 "SS 4 "e (E) SS TO REMAIN 2 "e W TO FD 2 "e V UP 4 "e W UP TO FD 1 ,.,, f., .W UP TO FIRE STANDPIPE DRAIN 4 "e W FCO If r (0-131 4 "SD UP / 2 "DCW UP PIPING UNDER SLAB _ -AND-ABOVE EXISTING FOOTING BEAM 6 "e SD • • {,QE / \ 13 City of Tukwila BUILDING DIVISION P.O.C. 12 "SD, VERIFY EXACT LOCATION I.E. 12.64 (APPROX.) 6 "0 RWL UP FOUNDATION LEVEL - PLUMBING PLAN 1/8" = 1' -O" �— P.O.C. 12 "RWL, SEE CIVIL DWG BEYOND 5' -O" OUTSIDE BLDG FOR CONTINUATION I.E: 15.37' 6 "RWL UP cIrvRiuLn SEP 21 2010 PERMIT CENTER 6 We Build Value • 4 acc. Y. i� 0 u a: Q. I m Commercial T.1. Permit 9404 East Marginal . Way South, Seattle, WA Commercial T.I. Permit Drawing. Title FOUNDATION LEVEL - PLUMBING PLAN Revisions No. Description Date Drawn by Author Checked by Checker Date August 18, 2010 Project No 210022 Consultant Project No Owner Project No Drawing. No P200 • L. r�O C/) z ¢¢ $ W'`c CC a a . zwo i 3 "e RWL DOWNSPOUT 4 "e RWL DN 1 "e NPCW UP TO RTU -1 4 "e W 2"e V U 2 "e CW 4TYP 11 Zia CW 1 1/2"e GAS (LP) 1 .1 /2 "e, (E)GAS VERIFY LOC. 2 "e •V CONNECT TO EXIST.�1 1 "eCW 3n0 .W a Ti 0' 0 z II Iti . E " I. 11710:: se it i rz. 1111 ci, _o E ":," CIC: 4 "e V_ CONNECT TO EXIST. 3/4°e HW 3 "e W 3/4 °e HW • . 3/4 "e HWC 2 "e V `: FD -2 2 "e (E)CW DOUBLE CHECK VALVE RPBP -1 8 P300 Commercial T.I. Permit SEE DETAIL. FD -1 1 1 /2 "CW & 1 "HW CONNECT TO EXIST. !i"e W STANDPIPE FOR FIRE TEST DRAIN 2 "e CW Drawing Title LEVEL ONE - PLUMBING PLAN Revisions No. Description Date ep 3 "RWL CONNECTION. CONNECT TO GUTTER DOWNSPOUT. SEE ARCH PLANS. 3 "e RWL x..'/ 6 "0 SD =- �z.,�„� -. - -.— \ L a , E1 � LEVEL ONE PLUMBING PLAN P20y 1/8" =1' -0" cmr SEP 21 2010 PERMIT CENTER Drawn by. Author: Checked by Checker Date August 18, 2010 Project No 210022 Consultant Project No Owner Project No Drawing No P201 eG r \\ I A (A.2i ■ $cof7 �F W 00t / i 1 A.8 +... }. . .... - xt f • eM ..._....._____- ___.._.._._.l .-. .._- ...:......__.......__.__.__ -.fit t____....- .�.� +:"'y____.. eJ ,— eK' r— . 4 "RWL UP; TO RD 4 "RWL UP TO RD I 4 "m RWL D i ,.� rf \`\ LEVEL TWO - PLUMBING P202 1 /8 =1-0" 6 "RWL UP — 3 4 It Vievv�"a . ,-Uh CODE COMP IA D AP ortlicoN CC 1 0 y City of Tukwila BUILDING DIVIS!O N cmrSA/IRMa SEP 21 2010 PERMIT CENTER Z J cc L U o I co — ice, Q co z U �mr W Q * , §sg � o a g Fig Z m r m� = M OO �a� 731 • rwo Ng, 0 II Cn Commercial T.1. Permit 9404 East Marginal Way South, Seattle, WA Commercial T.I. Permit Drawing Title LEVEL TWO - PLUMBING PLAN Revisions No. Description Date Drawn by Author Checked by Checker Date August 18, 2010 Project No 210022 Consultant Project No Owner Project No Drawing No P202 e2 j ORD -1 WI; mcila MC NMI u al. y I v) Commercial Tl. Permit 9404 East Marginal Way South, Seattle, WA eH Commercial T.I. Permit Drawing Title ROOF LEVEL PLUMBING PLAN 13 Revisions No. Description Date RD -1 RD -1 - vIvu,,;. onnE COMA` .gip 1 A`P Cityo fTukwila BUILDING DIVISION 1/8" =1' -0" CITYQ�U IILA SEP 21 2010-- ., --PERMIT CEkilift, Drawn by Author Checked by Checker Date August 18, 2010 Project No 210022 Consultant Project No Owner Project No Drawing No 6 "RWL UP TO ROOF DRAIN WITHIN GUTTER 6 "RWL UP TO ROOF DRAIN WITHIN GUTTER P203 "STONEMAN" #1100R FLASHING TURNED IN ON CAST IRON VENTS 3 Sc LARGER ONLY EXTEND WHERE REVD TO CLEAR FRESH AIR INTAKES, ETC. "STONEMAN" CAULK TYPE COUNTER - FLASHING SLEEVE FOR CAST IRON VENTS AND THREADED OR CAULK TYPE FOR ALL STEEL VENTS. PERMASEAL WATERPROOFING COMPOUND • STEEL REINFORCED BOOT "STONEMAN" SEAMLESS LEAD FLASHING #1100 -2 OR 1100 -4 WI 8" SKIRT BUILT -UP ROOFING 1 "URETHANE FOAM 2 "RIGID INSULATION RTITTiFfilliEWITRIMa P300 I[liill i PT METAL DECKING VENT THRU ROOF DETAIL SCALE: NONE SINGLE WALL HUNG BACK TO BACK WALL HUNG MIN WALL THICKNESS FOR WALL HUNG WATER CLOSETS P300 18x18x4 CONC. POUR LEAD CAULK TOP OF PLUG FLUSH W/ CONC. ROPE CAULKING OR UNK SEAL GRADE OR FLOOR TRANSITE SLEEVE THRU FOUNDATION WI 1" CLEARANCE AROUND FOOTING SHALL BE STEPPED DOWN WHERE REQ'D. PIPE SHALL NOT RUN UNDER FOOTING BOUNDARY LINE OF II PIPE TO FOUNDATION 1l 2 PIPE AT FOOTING DETAIL SCALE: NONE GCO IN WALKS AND SURFACED AREAS SHALL BE SIMILAR TO FCO EXCEPT JOSAM NUMBER 56050 OR 56040. TOP SHALL BE NICKEL BRONZE IN WALKS &.D000 C.I. IN OTHER SURFACED AREAS. FURNISH EXTENSION . SLEEVE TO SUIT ROOF CONSTRUCTION — ROOFING FOAM & RIGID INSULATION Whi vn1 METAL DECKIN G DRAIN BODY SUMP RECEIVER UNDER DECK CLAMP FCO SHALL BE JOSAM NUMBER 56000 OR 56010 FCO WITH LEAD SEAL. NICKEL BRONZE TOP & CUTOFF FERRULE. FINISHED FLOOR CONC. SLAB GCO IN UNSURFACED AREAS SHALL BE JOSAM NUMBER 58480 BRASS WITH COUNTERSUNK PLUG SCALE: NONE FLOOR CLEANOUT DETAIL P300/ SCALE: NONE r SPEC'D.BURY USE WYE FITTING AND PLUG WHERE CO OCCURS AT END OF UNE 1•� � +t i era I�:u ill ROOF DRAIN 9, /1111111 FEATHER INSULATION ROOF DRAIN DETAIL SCALE: NONE STUD WALL 1/2" B.V. TRAP PRIMER(TP) SECURE TO STUDS STAINLESS STEEL ACCESS DOOR AT 1- 12" AFF 1/2" CW FLOOR DRAIN, FLOOR SINK SIMILAR i Alm CW PIPE IN WALL Y- STRAINER UNION SEAL WATERTIGHT FIN. FLOOR CONNECT 1/2" CW TO TRAP AS REVD. P -TRAP NOTE: 1/2" C.W. PIPING BELOW FLOOR. SLOPE TOWARD DRAIN ALTERNATE TRAP PRIMER AND B.V. LOCATION ABOVE LAY -IN CEIUNG SEE FLOOR PLANS FOR LOCATIONS. FLOOR DRAIN TRAP PRIMER DETAIL P300 SCALE NONE OVERFLOW ROOF DRAIN W /2' DAM JEEP AUL ORL INSULATION OVERFLOW DRAIN ROOF DRAIN ORL RL MEM 45' Y CONNECTION IN VERTICAL RAIN WATER LEADER RL & ORL PIPING DETAIL SCALE: NONE BACKFLOW PREVENTER RPBP AIR GAP----N/ � TO FIXTURES RELIEF TO DRAIN NOTES: O1 INSTALL WITH REDUCED PRESSURE BACKFLOW PREVENTER (RPBP) ONLY (8 DETAIL - RPBP P300 SCALE: NONE GATE VALVE (TYP) UNION (TYP) STRAINER BUILDING WATER SUPPLY SPRING LOADED INLINE SOFT -DISC CHECK VALVE (TYP) O ScopE' DF WoR.k TG N IritVItVvtu rOFt CODE COMPLIANCE LLA u City of Tukwila BUILDING nivisiON ARAM SEP 21 2010 PERMIT CRIER u� N ti )- et O 4 cm� H O H 3 0o+cu CC 4a ��oo >.v Z ZWO♦` �3s °O� al 1 • 0 • U c ui) Museum of Flight Commercial T.I. Permit Commercial T"i. Permit Drawing Title PLUMBING DETAILS Revisions No. Description Date Drawn by UMC Checked by DM Date August 18, 2010 Project No 210022 Consultant Project No Owner Project No Drawing No P300